1 Square D Clipsal Outdoor Light-Level Sensor SLC5031PEWP for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use.

2 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Caution, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage or improper operation. NOTE: Provides additional information to clarify or simplify a procedure Schneider Electric. All Rights Reserved.

3 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin PLEASE NOTE Class B FCC Statement Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. This document is not intended as an instruction manual for untrained persons. No responsibility is assumed by Square D for any consequences arising out of the use of this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help Schneider Electric. All Rights Reserved. 3

4 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 INTRODUCTION Before You Begin This bulletin provides instructions for installing a Square D Clipsal Outdoor Light-Level Sensor. The SLC5031PEWP light-level sensor measures ambient light levels and automatically issues ON/OFF or ramp commands over a C-Bus network to maintain outdoor lighting levels. Primarily designed for outdoor use, this light-level sensor is also suitable for indoor settings in which a weather-resistant casing is desirable. The light-level sensor can control up to two C-Bus group addresses: one address controls the switching ON/OFF of a lamp circuit according to the amount of ambient light, while the other is used to continuously regulate the light-level output of any number of lamps. The target light level, the margin, and other sensor options are easily configured by using the C-Bus Toolkit software. Before installing an Outdoor Light-Level Sensor, verify that your order is complete by comparing the contents of the package with the items in the table below. Also verify that the catalog number on the box label matches your order. Table 1: Contents of the Package Part Number Description Quantity SLC5031PEWP Outdoor Light-Level Sensor Cover attachment screws (captive) Cover screw caps Insulated bootlace terminals 4 (2 required, 2 extra) NOTE: Installation of the sensor unit requires suitably rated sealant and weather-resistant conduit fittings, which are not included with the sensor Schneider Electric. All Rights Reserved.

5 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin Components The light-level sensor consists of a base unit and removable cover. The base unit contains the knockouts for the cable and for the mounting screws. The cover is also the sensor window. The sensor mechanism and four screw covers are mounted on the inside of the cover. Figure 1: Components of the Outdoor Light-Level Sensor KEY: A. 25mm Conduit fitting receptacle B. 20mm Conduit fitting receptacle C mm Conduit provision (back entry)* D. Mounting-screw knockouts E. Threaded post for cover screw F. Sensor G. Cover screw hole H. Screw covers I. Gasket * Must be cut using a drill and 20mm or 25mm hole saw Schneider Electric. All Rights Reserved. 5

6 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 Features Field of View Outdoor use, wall- and ceiling-mounted low-profile unit Can maintain a constant illumination level of foot-candles Adjustable light-level sensor has Sunrise/Sunset settings Control of up to two C-Bus group addresses Receives data and power over a C-Bus network, so the sensors do not require power packs or line-voltage connections These light-level sensor units have a 180 field of view and are designed for flush mounting on an outdoor wall or ceiling. Refer to the section, "Positioning Guidelines" for more information Schneider Electric. All Rights Reserved.

7 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin SAFETY PRECAUTIONS This section contains important safety precautions that must be followed before attempting to install or maintain electrical equipment. Carefully read and follow the safety precautions below. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury Schneider Electric. All Rights Reserved. 7

8 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 INSTALLATION Follow the steps outlined in this section to properly install the Outdoor Light Level Sensor. NOTE: Installation of the sensor unit requires suitably rated sealant and weather-resistant conduit fittings (not included). 1. Determine where the unit will be positioned in the designated area (see section Positioning Guidelines ). 2. Plan the site layout and verify that there will be enough power for all the units on the network (see section Network Considerations ). 3. Perform the following: basic configuration (unless the unit will be configured after physical installation), identification, and record the location of each unit (see section "Configuring, Labeling, and Recording the Locations of C-Bus Units" and "Components Needed for Configuring"). 4. Prepare and mount the base of the unit (see section Mounting the Sensor Base ). 5. Prepare a Category 5 data cable and connect it to the C-Bus network and to the sensor (see section "Wiring"). 6. Attach the sensor cover to the base. 7. Calibrate the unit (see section "Calibrating the Light-Level Sensor") Schneider Electric. All Rights Reserved.

9 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin Positioning Guidelines Network Considerations Use the guidelines below to determine where to position a unit that will be used indoors or outdoors. Position the unit so that the front cover is directed away from natural or artificial lighting sources. Position the unit in an area where the lighting is similar to that in the control area. Avoid dark or shady locations. Select a location where the unit can be easily accessed. Do not cover or obstruct the unit's field of view. If the unit will be used indoors, also consider the following guidelines: Position the unit 6.5 ft (1.9 m) or more above the floor so that it will not be obstructed. Position the unit so that the viewing window is directed toward the surfaces that require illumination. The Outdoor Light-Level Sensor can draw 18 ma from the C-Bus network. Determine the total network current load and verify that there will be enough C-Bus power to support all connected devices. Also verify that the amount of available power per C-Bus network is no more than 2A. Configuring, Labeling, and Recording the Locations of C-Bus Units C-Bus units must be configured, at a minimum, with the unit address and part name before being physically installed on the network. Each unit is identified by a unique serial number found on the box label (see the figure Example of a Box Label with Lift-and-Peel Section ). The serial number provides important information for recording a unit's location. An infrared barcode scanner may be used to read the box label's bar code for the serial number and unit information. Use the C-Bus Toolkit to assign the unit a unique address, and then mark the unit address and part name directly onto the unit before physical installation. You can use the lift-and-peel label from the unit box, or write the unit address and part name directly on the unit Schneider Electric. All Rights Reserved. 9

10 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 After marking the unit, record each unit's physical location onto a site plan or panel schedule. Figure 2: Example of a Box Label with Lift-and-Peel Section KEY: A. Serial number B. Bar code C. Lift-and-peel section HAZARD OF UNEXPECTED OR UNINTENDED OPERATION Properly configure, label, and record the location of each unit. Retain location records and provide them to the person(s) responsible for configuring and commissioning the network. Failure to follow these instructions can result in unintended C-Bus network operation. Components Needed for Configuration The following components are typically required for unit configuration. PC with the C-Bus Toolkit software installed. Unit to be configured. A PC to C-Bus network communication unit such as a C-Bus PC Interface (SLC5500PC) or C-Bus Ethernet Network Interface (SLC5500CN). Adequate C-Bus power (SLC5500TPS/SLC5500HPS or device power supplies) to support all connected devices. NOTE: A Powerlink NF3000G3C controller may be used with a PC Interface (SLC5500PC) to configure and operate C-Bus units Schneider Electric. All Rights Reserved.

11 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin Mounting the Sensor Base Follow the steps in this section to mount the unit and connect it to the C-bus network. Refer to the figure Components of the Light- Level Sensor. Removing the Cover from the Sensor Unit 1. Using a small Phillips screwdriver, remove and retain the cover screws at each corner of the sensor cover. 2. Remove and retain the cover. Mounting the Base to the Wall 1. Drill out the mounting holes in the sensor base. Refer to the figure "Components of the Outdoor Light-Level Sensor". 2. Smooth the edges of the drilled holes and remove any burrs and remove any debris from inside the base before mounting it. 3. If necessary, drill mounting holes in the surface where the sensor unit will be attached. 4. (Optional Step) Add a small amount suitably rated sealant such as silicon sealant to the unit's mounting holes before inserting the mounting screws. 5. Align the appropriate mounting holes in the sensor base with the mounting holes in the wall. 6. Thread the mounting screws into the mounting holes in the base. 7. Using a flat-bladed or Phillips screwdriver, tighten the screws until the back of the unit is held flat against the wall. Installing the Conduit Fittings In the sensor base, prepare the number of openings required for your sensor wire installation. 1. Using a large fat-bladed screwdriver, remove the 20mm or 25mm threaded conduit fitting receptacle caps. 2. Install the customer supplied conduit fittings into each cable opening to be used. 3. Remove and retain any unused conduit receptacle caps, apply PVC cement to the cap threads, and thread the caps into the receptacle. Tighten the cap using a flat-blade screw driver Schneider Electric. All Rights Reserved. 11

12 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 Rear Cable Entry Conduit Fittings (Optional) Follow the steps below to prepare the sensor base for attaching conduit fittings if rear cable entry is desired. 1. Using a drill and 20mm or 25mm diameter hole saw, cut a 20mm or 25mm hole. A center counter-sink guide is provided on the back of the sensor base to guide cutting. See the figure "Components of the Outdoor Light-Level Sensor". 2. Smooth the edges of the opening and remove any debris that may have fallen into the sensor base while cutting the hole. 3. Coat a customer supplied conduit fitting with a suitably rated weather-resistant sealant such as silicon sealant. Wiring Wiring Guidelines Follow the guidelines below when working with the Outdoor Light- Sensor. Level Verify that the power supplying the system is turned OFF before handling electrical power conductors. Observe national and local electrical codes. Isolate the Outdoor Light-Level Sensor from the Class 1 wiring. Consult your national and local electrical codes for requirements about isolating Class 1 wiring and Class 2 wiring terminals. Consult the "Electrical Wiring Connections" figure for all electrical connections. Prevent wire cuttings and debris from entering the unit. Megger Testing Guidelines Do not Megger test C-Bus data cabling or terminals. Megger testing of data cabling or terminals can degrade the performance of the C-Bus network. It will not harm the units if electrical power terminals only are Megger tested. But because units contain electronic components, the Megger readings will not be correct. To obtain valid readings, disconnect the power lines from the units Schneider Electric. All Rights Reserved.

13 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin HAZARD OF EQUIPMENT DAMAGE Do not Megger test C-Bus data cabling or terminals as it can degrade the performance of the C-Bus network. Failure to follow this instruction will result in damage to the C-Bus network. Connection to the C-Bus Network The Outdoor Light-Level Sensor is connected to the C-Bus network throug h a C-Bus network cable that uses unshielded twisted pair (UTP) Category 5 data cable. For optimal performance, use the connections recommended below for each end of the cable. Attach the terminal screws to the end of the cable. NOTE: The C-Bus network connection is polarity sensitive. The polarity is marked on the unit beside the terminals. NOTE: Do not solder wired used to connect the unit to the C-Bus through the terminal screws. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Do not connect line voltage to any C-Bus terminal. Failure to follow this instruction can result in personal injury or equipment or property damage Schneider Electric. All Rights Reserved. 13

14 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 Figure 3: C-Bus Wiring Connections KEY: A. C-Bus positive (+) B. C-Bus negative ( ) C. Remote OFF: brown + brown-white* D. Remote ON: green + green-white* Table 2: C-Bus Cable Conductor Assignments Terminal C-Bus Network Cable Color Connection Not connected Remote ON* Green-White Not connected Remote ON* Green C-Bus Neg ( ) C-Bus Neg ( ) Orange-White C-Bus Neg ( ) C-Bus Neg ( ) Blue-White C-Bus Pos (+) C-Bus Pos (+) Blue C-Bus Pos (+) C-Bus Pos (+) Orange Not connected Remote OFF* Brown-White Not connected Remote OFF* Brown *Not internally connected. Connecting C-Bus to Wiring Terminal Blocks Follow the instructions below to complete the C-Bus network connection. 1. Locate the terminal blocks on the unit. 2. Using a small flat-blade or Phillips screwdriver, loosen the terminal screws by turning them counter-clockwise. 3. Connect the terminated C-Bus network wires to the terminals on the unit. Turn the terminal screws clockwise to tighten them. 4. Verify that the polarity of the connections is correct Schneider Electric. All Rights Reserved.

15 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin Figure 4: Sensor Cover Components (inside view) KEY: A. Sensor unit B. C-Bus network wiring terminals C. Polarity markings D. Screw caps E. Cover mounting screw holes Re-Attach the Front Cover 1. Locate the screw caps inside of the sensor cover. 2. Using a small flat-bladed screwdriver or similar tool, gently pry the screw caps off the posts. Retain the screw caps. 3. Align the cover on top of the base and insert the four cover screws into the openings (one at each corner). 4. Tighten t he screws to 4.5 lb-in. ( 0.5 Nm). Do not exceed the specified torque value. 5. Place the screw caps into the screw openings. The caps help prevent moisture from entering t he unit and wiring Schneider Electric. All Rights Reserved. 15

16 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 CALIBRATING THE LIGHT-LEVEL SENSOR The light-level sensor must be calibrated in order to achieve the desired illumination level. Two methods for calibrating the light-level sensor are given below; one for sensors used indoors and outdoors, the other for sensors used indoors. Both methods use the C-Bus Toolkit software. NOTE: 1000 lux is approximately equivalent to 100 foot-candles. Calibrating the Sensor (Indoor or Outdoor Use) To calibrate the light-level sensor for indoor or outdoor use, you will use a pre-determined illumination value. NOTE: It might be necessary to adjust the settings to account for the difference in ambient light present on the sensor and that at the working surface. These differences can arise from the physical location of the sensor, the sensor's proximity to light sources, or shadows or diffusion effects. 1. Determine the preferred level of illumination in lux or footcandles. 2. In the C-Bus Toolkit software, open the user interface for the SLC5031PEWP. 3. Set the lux/foot-candle value by using the slider bar called "Target Lux/Foot-candle" (top right side of the program window). 4. Set the "Margin" slider to approximately 10% of the target lux/foot-candle. 5. Download the settings to the sensor unit Schneider Electric. All Rights Reserved.

17 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin Measuring and Setting the Level of Illumination (Indoor Use Only) The following method uses the C-Bus Toolkit software to measure and set the ambient light level. 1. Using C-Bus Toolkit software, open the user interface for the sensor. 2. In the room or area that is to be lit, adjust the ambient light to the desired level. 3. Look at the Ambient Light area on the left side of the program window. This area shows the current light level in lux/footcandles. Use this reading for the next step. 4. Use the lux/foot-candle reading to set the "Target Lux/Footcandle" slider in the top right side of the program window. 5. Set the "Margin" slider to approximately 10% of the target lux/foot-candle. 6. Download the settings to the sensor unit Schneider Electric. All Rights Reserved. 17

18 Square D Clipsal Outdoor Light-Level Sensor A3 Instruction Bulletin 11/2007 STANDARDS Table 3: U.S. FCC Regulations Standards/Regulations Title FCC Part 15 Complies with FCC Standards for Home or Office Use Table 4: European Directives and Standards European Council Directive Standard Title 89/336/EEC EMC Directive EN ; CISPR 14-1 RFI Emissions Standard EN ; IEC RFI Emissions Standard EN ; IEC RFI Emissions Standard BS/EN Immunity to ESD BS/EN Immunity to RFI BS/EN Immunity to EFT BS/EN Immunity to Surge Voltages BS/EN Immunity to Voltage Dips & Interruptions Schneider Electric. All Rights Reserved.

19 A3 Square D Clipsal Outdoor Light-Level Sensor 11/2007 Instruction Bulletin SPECIFICATIONS Table 5: Technical Specifications Nominal Voltage Requirements Field of View 180 Light-Level Range C-Bus Connection V 18 ma, drawn from the C-Bus network Reads: foot-candles ( lux) Controls: foot-candles ( lux) Screw-type input terminals accommodate 6 x 24 AWG cable (6 x 0.2 mm²); Connection requires CAT 5 data cable Max. Units/Network Based on the total network current load and available power. Conduit Openings Sized for 20 mm and 25 mm conduit fittings Dimensions 4 in. (L) x 4 in. (W) x 2.5 in. (D) [102 mm (L) x 102 mm (W) x 65 mm (D)] Weight 10.8 oz (305 g) Mounting Indoor or outdoor; Wall or ceiling;indoor Height: Min. 6.5 ft (1.9 m) above floor Operating Environment Outdoor or indoor; 22 F to 122 F ( 30 C to 50 C);RH: 95%, noncondensing DIMENSIONS 2007 Schneider Electric. All Rights Reserved. 19

20 Square D Clipsal Outdoor Light-Level Sensor Instruction Bulletin SUPPORT AND SERVICE Contact the Square D Customer Information Center for technical support by phone at Square D ( ) or at lightingcontrol.support@us.schneider-electric.com. Contac t your local Square D service representative or Square D Clipsal certified installer for repairs or service to your network. You may also find helpful information on our web site at Schneider Electric, USA 295 Tech Park Drive La Vergne, TN, SquareD ( ) Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Square D,, Clipsal, and C-Bus are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries Schneider Electric. All Rights Reserved A3 11/2007

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Ultrasonic Wall Switch Occupancy Sensor Single Circuit Instruction Bulletin 63249-420-414A1 02/2014 Ultrasonic Wall Switch Occupancy Sensor Single Circuit Commercial Grade with Ground, Single and Multi Location Switching SLSUWS1277C and SLSUWS3277C Retain

More information

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared

More information

180 Degree Ceiling Mounted Occupancy Sensors

180 Degree Ceiling Mounted Occupancy Sensors Instruction Bulletin 63249-420-386A 2/202 80 Degree Ceiling Mounted Occupancy Sensors PS-CDS800 and PS-CUS800 INTRODUCTION The 80 Degree Ceiling Mount Occupancy Sensors are ideal for use in business and

More information

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions 5102BCLEDL REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright

More information

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L C-Bus PIR Occupancy Sensor Installation Instructions 5751L Contents 1.0 Description 3 2.0 Important Notes 3 3.0 Installation 3 4.0 C-Bus Network Connection 6 5.0 Programming and Setup 7 6.0 Troubleshooting

More information

C-Bus Four Channel Analogue Output Unit Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions C-Bus Four Channel Analogue Output Unit Installation Instructions 5504AMP Series REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3 4.0 Wiring

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Explorer F210 Fuel Instrument Installation and Operation Manual

Explorer F210 Fuel Instrument Installation and Operation Manual Explorer F210 Fuel Instrument Installation and Operation Manual www.northstarnav.com 2 Northstar Explorer F210 Installation and Operation Manual IMPORTANT SAFETY INFORMATION Please read carefully before

More information

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions Ceiling-Mounted Motion Detector 752/CD, 752/CP, 752/CU and 752/Cx180 Installation Instructions Contents 1.0 Description...3 1.1 Contents of the Box...3 2.0 Safety...4 3.0 Coverage Patterns...4 3.1 PIR

More information

Operation and Maintenance Manual

Operation and Maintenance Manual M0075640-01 (en-us) September 2016 Operation and Maintenance Manual Product Link PLG641 and PLG601 for Generator Systems PL6 1-UP (Machine Control & Guidance Products) SAFETY.CAT.COM Important Safety Information

More information

C-Bus Neo Range Installation Instructions. 5050NL Series

C-Bus Neo Range Installation Instructions. 5050NL Series C-Bus Neo Range Installation Instructions 5050NL Series Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Installation Procedure... 4 3.1 Installation Location... 4 3.2 Installing

More information

PRODUCT DIAGRAM PACKAGE CONTENTS

PRODUCT DIAGRAM PACKAGE CONTENTS PRODUCT DIAGRAM PACKAGE CONTENTS After receiving the product, please inventory the contents to ensure you have all the proper parts, as listed below. If anything is missing or damaged, please contact Monoprice

More information

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing. Table of Contents Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1 GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E Figure 1 PET OWNERS WARNING: Health warning for some small pets, including birds, as they are extremely sensitive to the fumes produced

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

PRODUCT DIAGRAM PACKAGE CONTENTS

PRODUCT DIAGRAM PACKAGE CONTENTS PRODUCT DIAGRAM PACKAGE CONTENTS After receiving the product, please inventory the contents to ensure you have all the proper parts, as listed below. If anything is missing or damaged, please contact Monoprice

More information

Towel Warmer. Luxurious warmth for towels, robes and blankets

Towel Warmer. Luxurious warmth for towels, robes and blankets Towel Warmer Luxurious warmth for towels, robes and blankets Table of contents Warnings and Cautions................................................... 2 Location of Controls......................................................

More information

Installer Guide smart connect

Installer Guide smart connect Installer Guide smart connect TM 7490 Wireless Remote Outdoor Sensor Please read all instructions before proceeding. The wireless remote outdoor sensor monitors temperature at a remote outdoor location

More information

Installer Guide smart connect

Installer Guide smart connect Installer Guide smart connect TM 7390 Wireless Remote Indoor Sensor Please read all instructions before proceeding. The wireless remote indoor sensor monitors temperature at a remote indoor location and

More information

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed. Table of Contents Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

Projection Alarm Clock USER GUIDE

Projection Alarm Clock USER GUIDE Projection Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME, Warnings

More information

ITEM # SAIL STREAM CEILING FAN MODEL #41695

ITEM # SAIL STREAM CEILING FAN MODEL #41695 ITEM #1133114 SAIL STREAM CEILING FAN MODEL #41695 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 18 ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing

More information

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date ITEM #0807426 ARMITAGE CEILING FAN MODEL #CC52WW5L Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 17 ATTACH YOUR RECEIPT HERE Purchase Date 4009654 Questions, problems,

More information

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide Clean Base Automatic Dirt Disposal For Roomba i Series Robot Vacuums Owner s Guide Safety Information Important Safety Information This owner's guide includes information for Regulatory Model(s): ADE-N1

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L MAJIK OWNERS MANUAL i MAINS PLUGS This appliance is supplied with a non-rewireable mains plug for the intended country. Replacement mains leads can be obtained from your Linn retailer. Should you need

More information

Wireless High Bay Sensor (WHS100) Installation Instructions

Wireless High Bay Sensor (WHS100) Installation Instructions Installation Instructions The Daintree Networks WHS100 Wireless High Bay Sensor is a line powered control component within the ControlScope wireless building controls platform. It enables wireless control

More information

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047 ITEM #0803775, 0721899, 0807427 PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number

More information

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual READ ME FIRST DIY WIRELESS ALERT Add-on Alert Sensor For Swann Wireless Alert systems EN Instruction Manual 2 About this Manual The content in this manual is for information purposes only and is subject

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Fireplace User Guide MODEL#: EF16-60 SAVE THESE INSTRUCTIONS THIS PRODUCT WAS MANUFACTURED BY PAITE FOR ASHLEY FURNITURE INDUSTRIES, INC. All Rights Reserved. Page 1 of 15 Table Of Contents Table of Contents...2

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

1125 PIR Motion Detector

1125 PIR Motion Detector Tamper Survey LED INSTALLATION SHEET 1125 PIR Motion Detector Description The 1125 PIR (Passive Infrared) Motion Detector is a wireless, low current sensor for use with the 1100D Wireless Receiver. Using

More information

FTP-1000 Touchpad/Display Installation Manual

FTP-1000 Touchpad/Display Installation Manual FTP-1000 Touchpad/Display Installation Manual A B 1 2 3 4 5 6 7 8 9 0 * # Stay Away Disarm Quick Exit C D P/N 466-2231 REV B January 2011 Copyright Disclaimer Trademarks and patents Manufacturer Intended

More information

CR85. Instruction Manual TONE

CR85. Instruction Manual TONE CR85 Instruction Manual TONE 910-242500-002 WARRANTY Crosley Radio Products are warranted against defects in material and workmanship for a period of 90 days beginning from the date of sale to the original

More information

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting

More information

Fume Hood Operating Display Panel

Fume Hood Operating Display Panel Desigo TRA Fume Hood Operating Display Panel QMX3.P87 The Operating Display Panel (ODP) is the interface between the operator and the DXR Fume Hood Controller (FHC). LCD display for volume flow setpoint,

More information

ShockLink. Important Product Information.

ShockLink. Important Product Information. EN ShockLink Important Product Information www.laerdal.com English ShockLink Important Information Warnings and Cautions A Warning states a condition, hazard, or unsafe practice that can result in serious

More information

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE ITM. / ART. 1165831 Model: LM56123 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation,

More information

Vault Accessories Deluxe Kit

Vault Accessories Deluxe Kit Vault Accessories Deluxe Kit Instructions #1031640 Product #222498 A. B. D. C. E. A. Hygrometer B. 12 Dehumidifier C. Large Hanging Organizer D. Cordless Automatic Vault Light E. Magnetic Barrel Rest F.

More information

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0 Electric Fireplace Factory Model: EF-30D CONSUMER SAFETY INFORMATION Read this manual before installing and operating this appliance Failure to follow these instructions may result in electric shock, fire

More information

1126 Series Ceiling Mount PIR Motion Detector

1126 Series Ceiling Mount PIR Motion Detector Installation Sheet 1126 Series Ceiling Mount PIR Motion Detector Description The 1126 Series PIR (Passive Infrared) Motion Detectors are a compact wireless PIR. The 1126 Series offer 360, Wide Angle, or

More information

C-Bus Reflection Range Installation Instructions

C-Bus Reflection Range Installation Instructions C-Bus Reflection Range Installation Instructions R5060 Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Parts Supplied...3 4.0

More information

USER MANUAL OUTDOOR IR ILLUMINATOR

USER MANUAL OUTDOOR IR ILLUMINATOR USER MANUAL OUTDOOR IR ILLUMINATOR SAFETY INFORMATION 1.Before using the product, please carefully read through the safety information and operation 1instructions. 2.Take note of the Caution labels: Please

More information

Ionic Breeze QUADRA Silent Air Purifier. SI637 SI697 Instructions

Ionic Breeze QUADRA Silent Air Purifier. SI637 SI697 Instructions Ionic Breeze QUADRA Silent Air Purifier SI637 SI697 Instructions INCLUDES IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE SAVE THESE INSTRUCTIONS WARNING: To reduce the risk

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

Towel Warmer MAKE EVERYDAY A SPA DAY

Towel Warmer MAKE EVERYDAY A SPA DAY Towel Warmer MAKE EVERYDAY A SPA DAY TABLE OF CONTENTS Warnings and Cautions....1 FCC Information...4 Location of Parts and Controls...6 Set Up... 7 Using the Towel Warmer....8 Selecting the Timer...9

More information

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6 FV-08VQL6 FV-15VQL6 FV-11VQL6 2-3 5 5 6-8 FV-08VQL6 FV-11VQL6 11 Back cover Back cover Back cover FV-15VQL6 Thank you for purchasing this Panasonic product. For Your Safety To reduce the risk of injury,

More information

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.

More information

Little Anne. Important Product Information

Little Anne. Important Product Information EN Little Anne Important Product Information English Little Anne This Important Product Information covers Little Anne, Little Anne AED and Little Anne QCPR. Unless otherwise specified the information

More information

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS INSTALLATION INSTRUCTIONS Ventilating Fan ModelNo.FV-08VRE CONTENTS GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION (BETWEEN JOISTS MOUNTING)

More information

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100 The Digital Door Viewer! User Manual Motion Activated Sensor MAS 100 01- MAS100 Thank you for purchasing Motion Activated Sensor for Brinno PeepHole Viewer! Brinno MAS100 is an extension accessory for

More information

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions Description The NGC-UIT-ORD is a panel mounted display used in conjunction with other approved Raychem control and

More information

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647 Lightcloud is a commercial wireless lighting control system & service. It s powerful and flexible, yet easy to use and install. Learn more at lightcloud.com 1 (844) LIGHTCLOUD 1 (844) 544-4825 support@lightcloud.com

More information

POWERED ANODE SYSTEM

POWERED ANODE SYSTEM POWERED ANODE SYSTEM USER S GUIDE MODULE ANODE ELECTRODE Table of Contents Page SAFETY... 2 WIRING DIAGRAM... 2 INTRODUCTION... 3 INSTALLATION... 4 SYSTEM FEEDBACK... 6 REGULATORY NOTICES... 6 SPECIFICATIONS...

More information

Network Camera. Quick Guide DC-T1233WHX. Powered by

Network Camera. Quick Guide DC-T1233WHX. Powered by Network Camera Quick Guide DC-T1233WHX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

SEE DISCLAIMER ON REVERSE

SEE DISCLAIMER ON REVERSE BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer

More information

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze Harb or Breeze ITEM #0915543 BUILDER S SERIES CEILING FAN MODEL #41391 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 18 ATTACH YOUR RECEIPT HERE Purchase

More information

DeLaval activity meter system Instruction Book

DeLaval activity meter system Instruction Book Instruction Book 87224201 2014-02-17, Version 4 Original instruction Table of contents EC Declaration of Conformity -... 5 Safety precautions... 7 DeLaval activity meter AM2 DeLaval activity receiver

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents.   What to Expect with. Mounting Options. Tools Needed www.hunterfan.com Table of Contents What to Expect with Your Installation Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many

More information

F.P.O. Installation Guide. For Placement Only

F.P.O. Installation Guide. For Placement Only READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Federal regulations require ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the light

More information

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A Sundance Spas SPA EQUIPMENT SYSTEM Installation Instructions P/N 6530-456 Rev. A Contents Important Notices 1 Important Safety Instructions 2 Where to Place the Equipment System 3 Connecting Pipes Between

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 CEILING FAN. Owner s Manual Models #50336, 50337 52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.

More information

Installation Instruction

Installation Instruction KGADC0101BVC INTERNAL VENT KIT Installation Instruction NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual Homeowner s Installation Instructions & Operating Manual ELECTRIC HEATER WITH REMOTE CONTROL Model: GI-32-ZC IS-36-ZC, IS-42-ZC Insert surrounds READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual Daytime Fan-Aspirated Radiation Shield Kit Installation Manual For Vantage Pro2 & Vantage Pro2 Plus Stations Introduction The instructions describe how to upgrade a non-aspirated Vantage Pro2 radiation

More information

Blueair C User Manual

Blueair C User Manual Blueair C User Manual Before using Blueair Classic 200 series, please read this user manual carefully. Note: There may be local variations of these models. Contents General 4 Overview of unit 5 Adjusting

More information

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide Dahua HD Mini IR Waterproof Bullet Network Camera Quick Start Guide Version 1.0.0 Zhejiang Dahua Vision Technology Co., LTD Welcome Thank you for purchasing our Network camera! This user s manual is designed

More information

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual Daytime Fan-Aspirated Radiation Shield Kit Installation Manual For Vantage Pro2 & Vantage Pro2 Plus Stations Introduction The instructions describe how to upgrade a non-aspirated Vantage Pro2 radiation

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

programmable control model installation and setup guide M /11/ Hunter Fan Company

programmable control model installation and setup guide M /11/ Hunter Fan Company programmable control model 99107 installation and setup guide installation Prior to installation, download the app to ensure phone compatibility: Visit your app store and search simpleconnect to find the

More information

User Manual. 40 Tower Fan MODEL: WFTR40W

User Manual. 40 Tower Fan MODEL: WFTR40W User Manual 40 Tower Fan MODEL: WFTR40W 1. READ these instructions carefully before installing and operating the appliance. Keep them for further reference. 2. Record in the space below the SERIAL/MODEL

More information

Installation Instructions

Installation Instructions Installation Instructions S E C U R I T Y S Y S T E M Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations

More information

PowerLogic Branch Circuit Power Meter (BCPM)

PowerLogic Branch Circuit Power Meter (BCPM) PowerLogic Branch Circuit Power Meter (BCPM) Panel Board Monitoring System Installation Guide Branch Circuit Power Meter (BCPM) HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor Wiring

More information

Wireless Driveway and Intruder Alert

Wireless Driveway and Intruder Alert Wireless Driveway and Intruder Alert USER MANUAL SFA600 PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE. COMPLIANCE WITH FCC REGULATIONS

More information

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM) Installation Instructions The Daintree wall mounted Wireless Occupancy Sensor (WOS2-WM) operates seamlessly within the Daintree wireless lighting control platform. The WOS2-WM is a battery-powered occupancy

More information

Room Sensor for BACnet VAV Actuator

Room Sensor for BACnet VAV Actuator BACnet VAV Actuator Room Sensor Installation Manual IM 1038 Group: Controls Part Number: IM 1038 Date: 3/4/2010 Supersedes: New Room Sensor for BACnet VAV Actuator Model(s): 2508031 & 2508032 2010 McQuay

More information

IDP-Zone-6 Six Zone Interface Module

IDP-Zone-6 Six Zone Interface Module INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Zone-6 Six Zone Interface Module BEFORE INSTALLING If the modules will be installed in an existing operational system, inform the operator and local authority

More information

Installation Instructions

Installation Instructions Installation Instructions 3M Light Mat Series 3635-1000 Installation Bulletin 3635-1000 Release D, Effective July 2010 (Replaces C, Apr 2010) See Bulletin Change Summary at end of Bulletin Product Description

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

Twin Bell Digital Clock

Twin Bell Digital Clock Twin Bell Digital Clock Model: V50-500 Instruction Manual PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE AND KEEP IT FOR FUTURE REFERENCE. SPECIFICATIONS... 1 SAFETY INSTRUCTIONS... 2 FUNCTIONS...

More information

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles Installation Instructions Original Instructions CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles Bulletin Number 2100 Topic Page About This Publication 1 Important

More information

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM) 21233 Wireless Occupancy Sensor, Ceiling Mount Installation Instructions The Daintree Networks ceiling mounted Wireless Occupancy Sensor operates seamlessly within the ControlScope Manager (CSM), the Daintree

More information

Code 542 Peltier Rack User's Guide

Code 542 Peltier Rack User's Guide Code 542 Peltier Rack User's Guide LT2544/ 1999 Gilson, Inc. All rights reserved June 1999 Table of Contents page Introduction...1-1 Unpacking...1-2 Customer Service...1-3 Technical Specifications...1-4

More information

52 BERKSHIRE CEILING FAN

52 BERKSHIRE CEILING FAN 52 BERKSHIRE CEILING FAN Owner s Manual Models #20223, 20224 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9

More information

Home Doorway Alert Kit

Home Doorway Alert Kit READ ME FIRST DIY WIRELESS ALERT Home Doorway Alert Kit EN Instruction Manual 2 About this Manual The content in this manual is for information purposes only and is subject to change without notice. While

More information

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Installation Guide For Model: COS52OSB5CR E192641 net weight of fan: 21.78 lb (9.9 kg) Table of Contents: Safety Tips. pg. 1 Unpacking Your Fan. pg.

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions IFT-RC150 IntelliFire Touch Remote Control Installation Instructions Leave this manual with party responsible for use and operation. 1. Introduction The IFT-RC150 is a wall mounted device that is designed

More information

CONNEX Smart Thermostat CST R00

CONNEX Smart Thermostat CST R00 CONNEX Smart Thermostat CST-240 7215100100R00 Table of Contents Welcome... 3 Features... 5 Specifications... 5 Selecting the Heater Type... 5 Installation... 7 Control Panel (User Interface)... 9 Operation...

More information

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System USER MANUAL READ THIS ENTIRE MANUAL PRIOR TO INSTALLATION AND OPERATION We thank you for purchasing this Driveway Alert

More information

Instruction Manual and Warranty Information

Instruction Manual and Warranty Information CLEAN MIST TOP-FILL SENSATOUCH HUMIDIFIER WITH REMOTE CONTROL & AROMA TRAY TABLETOP & FLOOR STANDING Instruction Manual and Warranty Information IM0057A READ AND SAVE THESE INSTRUCTIONS Contents Safety

More information

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE INSTALLATION AND OPERATION INSTRUCTIONS MODEL NUMBER NXSMP-LMI PRECAUTIONS Read and understand all instructions before beginning installation. CAUTION: FOR USE

More information

WSD-E WHEEL DETECTOR QUICK REFERENCE GUIDE JUNE 2016 DOCUMENT NO. SIG-QG VERSION A

WSD-E WHEEL DETECTOR QUICK REFERENCE GUIDE JUNE 2016 DOCUMENT NO. SIG-QG VERSION A QUICK REFERENCE GUIDE WSD-E WHEEL DETECTOR JUNE 2016 DOCUMENT NO. SIG-QG-16-01 VERSION A Siemens Industry, Inc. Rail Automation 9568 Archibald Ave., Suite 100, Rancho Cucamonga, California 91730 1-800-793-SAFE

More information