ENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/
|
|
- Maximilian Greer
- 6 years ago
- Views:
Transcription
1 ENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/ Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon INTERNET: (503) FAX (503)
2 TABLE OF CONTENTS SECTION 1.0 SECTION 2.0 SECTION 3.0 SECTION 4.0 SECTION 5.0 SECTION 6.0 SECTION 7.0 SECTION 8.0 SECTION 9.0 RECEIVING AND INSPECTION GRAPHIC SYMBOLS THEORY OF OPERATION INTRODUCTION INSTALLATION OPERATION MAINTENANCE TROUBLESHOOTING PARTS LIST UNIT SPECIFICATIONS SCHEMATICS These units are for professional, industrial or educational use where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. These units are not intended for hazardous or household locations or use. 2
3 RECEIVING AND INSPECTION 1 Section Your satisfaction and safety require a complete understanding of this unit. Read the instructions thoroughly and be sure all operators are given adequate training before attempting to put the unit in service. NOTE: This equipment must be used only for its intended application; any alterations or modifications will void your warranty. 1.1 Inspection: The carrier, when accepting shipment, also accepts responsibility for safe delivery and is liable for loss or damage. On delivery, inspect for visible exterior damage, note and describe on the freight bill any damage found, and enter your claim on the form supplied by the carrier. 1.2 Inspect for concealed loss or damage on the unit itself, both interior and exterior. If necessary, the carrier will arrange for official inspection to substantiate your claim. 1.3 Return Shipment: Save the shipping crate until you are sure all is well. If for any reason you must return the unit, first contact customer service for authorization and supply nameplate data, including model number and serial number. Please see the manual cover for information on where to contact customer service. 1.4 Verify that all of the equipment indicated on the packing slip is included with the unit. Carefully check all packaging before discarding. These units are equipped with 2 shelves, 1 set Hanger Brackets for Shelves, 2 Hanger Rods for Shelves, and 4 leveling feet. 3
4 GRAPHIC SYMBOLS Section 2 Your incubator has been provided with a display of graphic symbols which is designed to help in identifying the use and function of the available user adjustable components. 2.1 Indicates that you should consult your manual for further description or discussion of a control or user item. 2.2 Indicates Temperature. 2.3 Indicates Over-Temperature Safety. 2.4 C Indicates Degrees Centigrade. 2.5 Indicates ON/I and OFF/O. 2.6 Indicates Relative Humidity. 2.7 Indicates Potential Shock Hazard behind this protective partition. 2.8 Indicates Protective Earth Ground. 2.9 Indicates Unit should be recycled (Not disposed of in land-fill) 4
5 THEORY OF OPERATION Section The Model HC6-2 Humidity Chamber is designed to maintain temperature from ambient +5 C to 100 C. The Humidity System is designed to control humidity from 40% to 80% between the temperatures 40 C to 100 C. 3.2 The Temperature control is a PID Set Point Control with timer. The controller has a RTD 100 ohm Input Sensor for controlling the temperature inside the chamber. The timer is preprogrammed from the factor for a 20 minute count down after Set Point is reached. (Only if the timer functions is activated.) After 20 minutes, a buzzer will sound for a period of 5 minutes unless it is deactivated. 3.3 The Humidity Control is a PID Set Point Control with Timer. The Controller Sensor is a HMM30C Vaisala Humidity Sensor Set Up for a 0-10VDC input. Where 0VDC=0% humidity and 10VDC=100% Humidity. The timer is preprogrammed from factory for a 5 minute countdown after Set Point is reached only if the timer function is activated. After 5 Minutes, a buzzer will sound for a period of 5 minutes unless it is deactivated. 5
6 INTRODUCTION HC6-2 chambers are designed specifically to create conditions with relative humidity of 40-80%. The chamber features rapid condition recovery after the chamber door is opened and closed. The large viewing area offers easy observation of critical samples. The chamber interior is made of high quality, corrosion resistant material. Specifications Temperature Uniformity +0.5C Temperature Control 40ºC to 100C Humidity Range 40 to 80% RH (of specified temperature range) Humidity Control +5% Interior Dimensions 24 W x 18 D x 22 H Exterior Dimensions 29.5 W X 27 D X 37 H with Carboy Holder 36.5 W X 27 D X 37 H Shelf Work Area 21 W X 14 D Electrical V, 8 A, 60 Hz Features Digital temperature and humidity display, PID control 1/8DIN, set-point & process value displayed simultaneously with built in timers. Rapid recovery after chamber door is opened and closed Solid state sensors eliminate need for frequent replacement of wicks Chamber interior made of high quality, corrosion resistant material Forced air flow to ensure uniform internal conditions Large front viewing window Low water level indicator Humidity injection indicator Heating indicator OTL Thermostat with OTL Indicator Section 4 6
7 INSTALLATION Unpacking This product has been completely tested, cleaned and packed for shipment. Carefully remove all packing material. Please examine the chamber completely. Should any damage be found, notify the delivering carrier immediately. Report any shortages to your local distributor or contact SHELDON MANUFACTURING, INC. customer service at (503) , (800) (USA only) or Chamber Location The chamber must be located in a dry, clean, and level area. Allow a 2 inch (51 mm) clearance from the back of chamber for proper air circulation. Locate the chamber in an area out of direct sunlight and away from heating and cooling ducts. Caution: Do not put more than 5 lbs (2.3kg) on top of unit. Section 5 The figure below shows the exhaust port on the back of the chamber. Install rubber stopper (with 90 Copper Vent Tube) into port and press in firmly. If external ducting to a fume hood or exterior vent is necessary, make connection here. Note that temperature, humidity, and recovery time may be affected. Power Requirements The power cord of this chamber is equipped with a grounded plug. Be sure to connect the ground. SHELDON MANUFACTURING, INC. recommends that the chamber have a dedicated wall outlet. Verify correct power supply required for particular unit. Water Connections Plumb the water drain connection to a facility drain. Connect the water inlet to a water supply. The chamber requires distilled, reverse osmosis or deionized water with 7
8 resistivity between 0.05 & 1 Mega Ohmn-cm and ph above 6.5. Using water outside this range will void the warranty. Carboy water bottle (optional) Mount the universal carboy holder either on the top of the chamber or on the side (as shown below). Use the mounting screw holes provided and secure the holder. Connect tubing to carboy, fill bottle and install as shown. The water supply must gravity drain. The bottle cap must have a weep hole for it to work properly. 8
9 Condensate Recirculating System (optional) The Condensate Recirculating System can be used in conjunction with SHELDON MANUFACTURING, INC. s HC6-2 chambers as a water delivery system. This system is typically used in facilities where a drain or in-house source of distilled, RO or deionized water is not available. The system provides continuous, clean, filtered water to the chamber s humidity injection system, collects and recycles the condensate that forms in the base of the chamber. Use fittings provided with unit for hook-up. Install Shelf / Hanging Rails Insert both shelf tracks into the chamber (see picture below). Each unit is equipped with both a shelf and evidence rails/clips. Orient the shelf handle toward the front. Maximum shelf load is 22lbs (10kg) per shelf. Sliding shelf Right shelf track 9
10 OPERATION Section 6 Start Up Turn all switches on Front Panel to the OFF position. Plug unit into correct rated outlet in the wall. Be sure the water connections are properly made and the Exhaust Stopper and Vent Tube are installed. Turn power switch to ON position. The Power Light, SL Logo, and Temperature Control should illuminate. Setting Temperature and OTL Thermostat Turn OTL Thermostat dial to maximum setting. Push either UP or DOWN Arrow on Temperature control once and then use the UP or DOWN Arrows to set desired temperature. The Set Point Display (bottom display) will move up or down according with the up or down arrows. After the desired set point is reached, the Set Point Display will blink once after a few seconds after entering the Set Point into the control. Allow unit to stabilize for several hours. Turn the OTL Dial Counter Clockwise slowly until the OTL Light starts blinking and Heating Light stops blinking. Then, turn OTL Dial clockwise slowly until OTL Light stops blinking and Heating Light starts blinking. Continue turning OTL Dial Clockwise about 1/16 (1.59mm). If the unit is used at different process temperatures, pick the highest process temperature to set OTL or the OTL will have to be each time for different process temperatures. Countdown Timer The Countdown Timer provides users with a way to alert them to check or remove chamber contents. It does not turn the chamber off or in any way affect the temperature or humidity control. Both temperature and humidity controls have built in timer functions. The temperature control is preset at the factor for 20 minutes. Using Timer Both Temperature and Humidity Control Timer functions are the same. After opening door, contents have been placed in chamber and door is closed, push the Function Key 10
11 once and the preset time will appear in the bottom display, the timer will start counting down only when the temperature or the humidity control set point are reached. After the countdown is complete, the buzzer sounds alerting the user that chamber contents need to be check or removed. The buzzer is programmed to shut off automatically after 5 minutes. To shut buzzer off manually or abort timer function at any time, push the Function Key Once. Changing Timer Preset Time Procedure is the same for both Temperature and Humidity Controls. Push the Program Button once. Use the UP and DOWN arrows to scroll programming parameters (CONF, PARA, OPER). These parameters will appear in the Bottom Display. Scroll until OPER appears in the Bottom Display and push the Program Button again. Now you have entered the Operation Parameter List Menu and SP1 will appear in the Bottom Display. Use the UP or DOWN Arrows to scroll through Parameter List until t1 appears in the Bottom Display. This is where the preset time is stored. To change time, push the Program Button and the t1 will start blinking. Use the UP and DOWN Arrows to change desired time. After time is entered, wait until Top Display blinks and t1 stops flashing. Press the Function Key Normal Display. repeatedly to exit back out to Using Humidity Function Before using Humidity, allow unit to warm up interior walls and glass for 30 minutes after temperature set point has been reached to avoid condensation buildup on interior walls and glass. Turn the Humidity Switch to the ON position. The Humidity Control will illuminate and the Water Fill Light will illuminate. The Humidity Tank Reservoir will fill up (approximately 30 seconds) and the Water Fill Light will go out. To set the RH% Set Point, use the same method as described in Setting Temperature in Setting Temperature and OTP Section. Viewing LIght Turn Interior Light Switch to ON position. Calibration Both Temperature and Humidity Controls use an Offset Calibration Method and are done the same way. Place an independent temperature and humidity measuring device in chamber. Select desired set point and allow several hours to stabilize. To enter offset in either control, push the Programming Button once. Use the UP and DOWN arrows to scroll programming parameters (CONF, PARA, OPER). These parameters will appear in the bottom display. Scroll until CONF appears in the Bottom Display and push the Programming Button again. Now you have entered the Configuration List Menu. Using the UP and DOWN Arrows to scroll through the list until 11
12 INP appears in the Bottom Display and push the Programming Button again. Now you have entered the Parameter Configuration Setting List for Control Input 1 and SENS should appear in the Bottom Display. Using the UP and DOWN arrows until OFFS appears in the Bottom Display. This is where the Controls Offset Calibration is stored. To change the offset, push the Programming Button once and OFFS will start blinking. Using the UP and DOWN Arrows to change the desired offset. After the offset is entered, the Top Display will blink once and the OFFS will stop blinking. Press the Function Key repeatedly to return to EXIT and back out to Normal Display. Switching Chamber from Humidity to Oven Operation Condensation is common and should be expected in a Humidity Chamber. When switching from Humidity to an Oven Operation, turn the Humidity off. Then, set the Set Temperature to 100 C. Open the door for 30 minutes. After that time, close the door for 40 minutes. This should allow the chamber time to dry before the Oven Operation. 12
13 Temperature Setup CONF MENU INP SENS 2 OFFS 0 df 1.6 UNIT 1 LC LC1 LC2 FNTC 0 FNTC 2 BINF BIN1 0 CNTR CtYP 1 CACt 1 HANd 101 Rout 0 SPL 20 SPH 100 CPr 1 tfct FNCt 1 Strt 0 UNIt 0 SIGN 1 t1 20:00 t2 5 tolt 1 rafc FNCt 0 Humidity Setup CONF MENU OTts P Out L OUt 1 9 OUt 2 0 OUt 3 1 disp disu 2 disl 3 dist 1 out 180 Tres 0 desp 0 tas 4 tast 0 INP SENS 25 OFFS 0 SCL 0 SCH 100 Df 3.0 UNIT 1 LC LC1 LC2 FNTC 0 FNTC 0 BINF BIN1 0 CNTR CtYP 1 TEMPERATURE PID VALUES PARA Pb1 2 dt 13 rt 54 cy Hyst 1.0 Y0 0 Y1 100 Y2-100 CACt 1 HANd 101 Rout 0 SPL 0 SPH 80 CPr 1 tfct FNCt 1 Strt 0 UNIt 0 SIGN 1 t1 5:00 t2 5 Tolt 1 rafc FNCt 0 OTts P Out L OUt 1 9 OUt 2 0 OUt 3 1 disp disu 2 disl 3 dist 1 tout 180 Tres 0 desp 0 tas 4 tast 0 HUMIDITY PID VALUES PARA Pb1 3 dt 40 rt 175 cy1 1.0 HysI 1.0 Y0 0 Y1 100 Y
14 MAINTENANCE Section 7 Note: Prior to any maintenance or service on this unit, disconnect power cord from the power supply. Fuses are located on the back of the unit next to power cord. Electrical components are located underneath the top/back panel. For additional service support, contact your local distributor or Sheldon Manufacturing, Inc. Customer Service at tech@shellab.com. When contacting Sheldon, please provide model number and serial number Routine Maintenance Routine chamber maintenance is necessary to keep the chamber working properly. The recommended chamber maintenance schedule is: a) Clean interior chamber (as needed) b) If the humidity control portion of the chamber is going to be unused for 20 days, the small internal water reservoir should be drained. To drain the internal reservoir: vent (remove stopper) c) Check drains for blockage (monthly) WARNING: Before removing top/back panel, disconnect all power! 14
15 TROUBLESHOOTING Section 8 Always make a visual inspection of the unit and control console when troubleshooting. Look for loose or disconnected tubing and wires which may be the source of the trouble. PROBLEM Unit won t reach temperature set point Temperature displayed is different than measured temperature inside chamber POSSIBLE SOLUTION Is the set point within the unit specification range? Is the door closed and latched? Can air flow freely throughout the chamber? Inhibited air flow can trip the over temperature safety device. Remove airflow obstructions and let stabilize for 30 minutes Can air flow freely throughout the chamber? Calibrate the Control Temperature is higher than set point Is the set point within the unit specification range? Is the ambient temperature no more than 25ºC? Turn unit off and open door for 1 hour. Humidity controller is blank (temperature controller is illuminated) Is the humidity enabling switch on? Unit won t reach humidity set point Is the low water level light on? Is there adequate water supply? Can air flow freely throughout the chamber? Is the humidity set point within the unit specification range? Low water light stays lit Is the water supply connected? Is there adequate water being supplied to the chamber? Are there any air traps in the line? If using a carboy or other reservoir, is there a weep hole to allow free flow? Humidity displayed is different than measured humidity inside chamber Can air flow freely throughout the chamber? Calibrate control Interior lights won t come on Are lights turned on? Glass fogs up on inside Has the unit stabilized 1 hour? Residual Moisture in the bottom tray of chamber. When operating in Humidity Mode, moisture collecting in the bottom tray is normal. After performing Switching Chamber from Humidity to Oven Operation procedure, the moisture should evaporate. 15
16 PARTS LIST Description V Section 9 ALARM BUZZER CHAMBER FAN FUSE FUSE HOLDER EMI FILTER CONTROL DOOR TEMPERATURE LED LIGHT STRIP OTP LIGHT RED POTENTIOMETER POWER CORD POWER SUPPLY 24 VDC 2A POWER/HEATING LIGHT GREEN PROBE RTD RELAY SOLID STATE 45A DC RELAY TIME DELAY RESISTOR ROUND CHERRY SWITCH SENSOR RH SOLENOID WATER FILL
17 WIRING DIAGRAM HC V ( ) 17
18 FROM RELAY 1 TERM 4 FROM TEMPERATURE CONTROL SEE PAGE 1 FOR MAIN CONTROL WIRING FROM RELAY 1 TERM 3 WHT FLOAT SWITCH R2 COIL ~~~~~ 6 2 STEAMER RELAY R GRY 8 7 BLU BLU WATER SOLENOID WATER FILL LIGHT (R) WHT WHT WHT WHT 150 C ½ TB2 L1-SW 6 4 STEAMER RELAY R SOLID STATE RELAY YEL 5 10 (L1) 4 9 (L2) 3 8 (NC) 2 7 (C) 6 (NO) WHT RED WATLOW FIXED LIMIT YEL TC PROBE RH INJECT LIGHT (G) WHT ½ TB2 L2-SW RED HT HT WHT RED STEAMER ELEMENT 240V/500W CARTRIGE STYLE 108 (COLD) JUMO ctron N L1 OUT IN HUMIDITY SENSOR RED WHT 24VDC POWER SUPPLY RED WHT 18
19 SHELDON MANUFACTURING, INC. LIMITED WARRANTY Sheldon Manufacturing, Inc., ( Manufacturer ) warrants for the original user of this product in the U.S.A. only that this product (parts only if outside of the U.S.A.) will be free from defects in material and workmanship for a period of one year from the date of delivery of this product to the original user (the Warranty Period ). During the Warranty Period, Manufacturer, at its election and expense, will repair or replace the product or parts that are proven to Manufacturer s satisfaction to be defective, or, at Manufacturer s option, refund the price or credit (against the price of future purchases of the product) the price of any products that are proven to Manufacturer s satisfaction to be defective. This warranty does not include any labor charges if outside of the U.S.A. This warranty does not cover any damage due to accident, misuse, negligence, or abnormal use. Use of Manufacturer s product in a system that includes components not manufactured by Manufacturer is not covered by this warranty. This warranty is void in the event that repairs are made by anyone other than Manufacturer without prior authorization from Manufacturer. Any alteration or removal of the serial number on Manufacturer s products will void this warranty. Under no circumstances will Manufacturer be liable for indirect, incidental, consequential, or special damages. The terms of this warranty are governed by the laws of the state of Oregon without regards to the principles of conflicts of laws thereof. If any provision of this limited warranty is held to be unenforceable by any court of competent jurisdiction, the remainder of this limited warranty will remain in full force and effect. This warranty is in lieu of and excludes all other warranties or obligations, either express or implied. Manufacturer expressly disclaims all implied warranties, including without limitation, the warranties of merchantability and fitness for a particular purpose. For fast and efficient support, please have the following information available anytime you request service: Model Serial No. Part No. 19
MODEL 6105 FINGERPRINT DEVELOPMENT CHAMBER OPERATIONS MANUAL
MODEL 6105 FINGERPRINT DEVELOPMENT CHAMBER OPERATIONS MANUAL PO Box 715 Marietta, OH 45750 800-648-3042 740-373-6809 Fax 740-374-3760 www.caronproducts.com service@caronproducts.com Dear Valued Customer:
More informationDear Valued Customer:
Dear Valued Customer: Thank you for purchasing CARON Products & Services equipment. We appreciate your business and look forward to being your preferred supplier of controlled environment equipment products
More informationINSTALLATION AND OPERATION MANUAL
ECONOMY OVENS SMO1E SMO3E MODELS OBSOLETED AFTER MAY 31ST SMO1E-2, SMO3E-2, SMO5E, SOM5E-2 INSTALLATION AND OPERATION MANUAL Revised June 13, 2017 861659 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,
More informationREACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL
REACH-IN INCUBATOR MODEL: RI28/RI40 2/13 4861573-1 INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationVACUUM OVEN. Model: VPX9-2. Installation and Operation Manual
VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897
More informationMODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL
ECONOMY VACUUM OVEN MODEL: 1407, 1407-2, 1408, & 1408-2 INSTALLATION AND INSTRUCTION MANUAL Sheldon Manufacturing Inc. P.O. Box 627, Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationBOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/
BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/12 4861576-1 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationVACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL
VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationINSTALLATION AND OPERATION MANUAL
MICROPROCESSOR CONTROLLED OVEN MODELS: CE3F & CE5F 11/11 4861579 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationDear Valued Customer:
Dear Valued Customer: Thank you for purchasing CARON Products & Services equipment. We appreciate your business and look forward to being your preferred supplier of controlled environment equipment products
More informationBOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual /12
BOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual 861666-1 05/12 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationINCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL
INCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL These units are UL listed general purpose air incubators for professional, industrial or educational
More informationVACUUM OVEN MODEL: 1425, 1445 & idealvac.com (505)
idealvac.com (505)872-0037 idealvac.com VACUUM OVEN MODEL: 1425, 1445 & 1465 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET:
More informationRevised 01/
HUMIDITY CHAMBER SHC10 SHC10-2 SHC10R SHC10R-2 SHC28 SHC28-2 SHC28R SHC28R-2 PREVIOUSLY DESIGNATED AS : HC9 HC9-2/ HC9R HC9R-2 HC0 HC0-2 / HC0R HC0R-2 WITH MICRO PROCESSOR CONTROL INSTALLATION AND OPERATION
More informationSPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.
StableTemp Low Temperature Incubator Model 146E Catalog Number 39063-00(115VAC) 39063-05(230VAC StableTemp Low Temperature Incubator offers laboratories precise temperature control over the -10 C to 60
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationIsotemp Plus General Purpose Laboratory Freezers
Isotemp Plus General Purpose Laboratory Freezers Catalog Numbers: 13-986-142/142R 13-986-143/143R 13-986-144/144R 13-986-147/147R 104215 Rev. A Table of Contents Introduction...3 Safety Precautions...3
More informationSHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS SHC10R SHC28 SHC28R HUMIDITY CHAMBER. Revised March 19,
HUMIDITY CHAMBER SHC10 SHC10R SHC28 SHC28R SHC10-2 SHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS Revised March 19, 2018 4861578 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon
More informationOPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationReacti-Therm I and III Heating Modules
INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1
More informationINSTALLATION AND OPERATION MANUAL
REACH-IN DRY CO 2 INCUBATOR SCO31 SCO31-2 SCO40 SCO41-2 PREVIOUSLY DESIGNATED AS 2428 2428-2 2440 2440-2 Revised 12/2013 4861504 INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationCorning LSE 6L Digital Water Bath
Corning LSE 6L Digital Water Bath INSTRUCTION MANUAL Models 6783 (120V US) 6784 (230V EU) Table of Contents 1.0 Warning 1 2.0 Safety Information 1 3.0 Package Contents 1 4.0 Unpacking 2 5.0 Installation
More informationWhynter Portable Ice Maker 33 lb capacity - White
Whynter Portable Ice Maker 33 lb capacity - White Model # : IMC-330WS INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully
More informationInstructIon Manual KrEs EQuIPMEnt stands
Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available
More informationINSTALLATION AND OPERATION MANUAL
LOW TEMPERATURE DIURNAL ILLUMINATION INCUBATOR SRI21D SRI21D-2 Previously designated as: LI15 LI15-2 INSTALLATION AND OPERATION MANUAL Revised 4/2015 4861575 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius,
More informationReacti-Therm I and III Heating/Stirring Modules
INSTRUCTIONS Reacti-Therm I and III Heating/Stirring Modules TS-18821 TS-18823 Number TS-18821 TS-18823 Description Reacti-Therm I Heating/Stirring Module (single block) Reacti-Therm III Heating/Stirring
More informationWMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit
January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow
More informationECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL
ECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationHORIZONTAL AIR FLOW CLEAN ROOM OVEN
HORIZONTAL AIR FLOW CLEAN ROOM OVEN MODEL: CR1-2 INSTALLATION AND OPERATIONAL MANUAL P.O. Box 627 300 N. 26 th Avenue Cornelius, Oregon 97113 EMAIL:tech @ Shellab.com INTERNET: http://www.shellab.com 1-800-322-4897
More informationWITH OMRON E5CC CONTROL
LABORATORY OVENS, FAN FORCED & GRAVITY CONVECTION. MODELS: TO-152G & TOH-152G TO-152F, TOH-152F & TO-235F TO-330F & TO-500F WITH OMRON E5CC CONTROL Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline
More informationIsotemp Low Temperature Incubator
Isotemp Low Temperature Incubator Instruction Manual Model 307C Cat. No. 11-679-25C LT1883X2 11/13/06 Table of Contents Safety Information...3 Alert Signals...3 Warning...3 Caution...3 Important...3 Introduction...4
More informationFLCH4R Garage and Utility Electric Heater
FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600
More informationUser Manual. Hot Dog Steamers. Models: HDS100, HDS175, HDS200 06/2018. Please read and keep these instructions. Indoor use only.
Hot Dog Steamers Intertek Models: HDS100, HDS175, HDS200 06/2018 Please read and keep these instructions. Indoor use only. www.avantcoequipment.com 1 BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES
More informationRefrigerated Incubator Model and Operating Instructions
Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.
More information3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A
Versa-Roll Roller Apparatus - Modular CLS-3857 OPERATIONS MANUAL 3800 North Mill Road Vineland, NJ 08360 USA Tel: 1-800-843-1794 Fax: 1-800-922-4361 Web: www.cglifesciences.com Rev. A Contents: General
More informationSANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION
MODEL #750 SANI-VAC WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION INSPECTION Open the container in which the Sani-Vac was shipped and inspect it. Should
More informationTTT Digital Incubator
TTT Digital Incubator 135000 135000-2 Operating Instructions N2400342 Rev. 1 08/13 Table of Contents 1.0 Safety... 3 2.0 Intended Use of Product... 4 3.0 Installation... 4 3.1 Unpacking the Unit... 4 3.2
More informationPOLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL
POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page
More informationOperators Manual. Microprocessor Controlled. Water Baths
Operators Manual Microprocessor Controlled Water Baths 110-288 Rev A 09/04 Table of Contents Section 1 - General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description Section 2 -
More informationREFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual
REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationInstruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath
Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath REVOLUTIONARY SCIENC E Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards
More informationCWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual
CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference
More informationFS Series Forced Air Ovens. Operation and Service Manual
FS Series Forced Air Ovens Operation and Service Manual TestEquity LLC 6100 Condor Drive Moorpark, CA 93021 Support: 877-512-3457 Toll Free 805-480-0638 Corporate: 800-732-3457 805-498-9933 http://www.testequity.com
More informationOperator s Manual. Histology Bath
Operator s Manual Histology Bath 110-827 05.09.12 Table of Contents Introduction... 2 General Safety Information... 2 Safety Recommendations... 3 Unpacking Your Histology Bath...4 Contents...4 Components
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators
More informationPortable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217
Portable Air Conditioner with Heat Pump Technology Operating Instructions 3092402 Model No.: HCB-P13HP-D Reference No.: BPD13HP V140217 Thank you for choosing a Soleus Air Portable Air Conditioner with
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR AQUECOIL HYDRONIC HEATING UNITS GENERAL INFORMATION The AQUECOIL Hydronic Heating Unit is offered in many different capacities and physical configurations in order to match
More informationInstruction Manual. Astro Staging Cabinet
Instruction Manual Astro Staging Cabinet 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 40269 SAFETY PRECAUTIONS DANGER Machine must be properly grounded to
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationPORTABLE AIR CONDITIONER OWNER S MANUAL
PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 WARNING: Read and follow all warnings and instructions in this
More informationHenny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL
Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL THIS PAGE INTENTIONALLY LEFT BLANK. Section TABLE OF CONTENTS Page Section 1. TROUBLESHOOTING... 1-1 1-1. Introduction... 1-1 1-2.
More informationDUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL
DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationCR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions
OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight
More informationModel No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions
Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable
More information10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN
More informationInstruction Manual Item No.: V~, 60Hz
Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction
More informationOperator s Manual. IP-100 Immersion Probe Cooler
Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11 Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your
More informationDROSOPHILA SPECIFIC INCUBATORS SRI21F SRI21F-2 Previously designated LIFLY LIFLY-2 Installation and operations manual. Revised 4/
DROSOPHILA SPECIFIC INCUBATORS SRI21F SRI21F-2 Previously designated LIFLY LIFLY-2 Installation and operations manual Revised 4/2015 4861614 Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113
More informationDROSOPHILA SPECIFIC INCUBATORS MODEL: LIFLY & LIFLY-VIEW Installation and operations manual
DROSOPHILA SPECIFIC INCUBATORS MODEL: LIFLY & LIFLY-VIEW Installation and operations manual Sheldon Manufacturing Inc. P.O. Box 67 Cornelius, Oregon 973 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab
More informationCLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N
CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3
More informationOperating Instructions
PH5-13R-35D Portable Air Conditioner with Heat Pump Operating Instructions 3092402 Item Number: LX-130 Model Number: PH5-13R-35D 201 Soleus Air International Thank you for choosing a Soleus Air PH5 Series
More informationLABORATORY ILLUMINATED FLOTATION BATH
LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851
More informationCA5000 Liquid CO 2 Freezer Backup System
CA5000 Liquid CO 2 Freezer Backup System OPERATING INSTRUCTIONS MANUAL HAMPSHIRE CONTROLS CORPORATION ONE GROVE STREET / P.O. BOX 516, DOVER, NEW HAMPSHIRE USA 03821 TEL. (603) 749-9424 FAX (603) 749-9433
More informationRemote Relay Module (RRM)
Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like
More informationSafety, Installation, and Operation Manual
Automatic Steam Humidifier Control Safety, Installation, and Operation Manual READ COMPLETE INSTALLATION INSTRUCTIONS BEFORE STARTING. WARNING This product must be installed by a qualified heating and
More informationModel 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA
Model 20201/20201-A/20201-B Wind Sensor Heater User's Manual All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA www.allweatherinc.com 20201 Wind Sensor Heater User's Manual CONTENTS INTRODUCTION...1
More informationMobile Hot Food Merchandiser Series. Series: MHB Operation Manual
Mobile Hot Food Merchandiser Series Series: MHB Operation Manual BKI LIMITED WARRANTY Grandview Drive Simpsonville, SC 0 USA () - Toll Free: (00) - Fax: () - WHAT IS COVERED WHO IS COVERED COVERAGE PERIOD
More informationMD-MINI Dry Bath. Instruction Manual
MD-MINI Dry Bath Instruction Manual Catalog No. MD-MINI www.majorsci.com service@majorsci.com Version 01B Revision on: 2013.07.15 Packing list MD-MINI: 1x MD-MINI Dry Bath 1x MD-MINI Lid 1x Power Cord
More informationNote To The User: This product has updated features not yet mentioned in the product manual.
PLEASE READ BEFORE OPERATING THE PRODUCT--- Note To The User: This product has updated features not yet mentioned in the product manual. Celsius / Fahrenheit toggle: To switch the reading between Celsius
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales CONFECTIONERY USE & SERVICE MANUAL WARRANTY INFORMATION For Models Bradford
More informationGASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS
More informationMST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL
MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL IMPORTANT WARNING WHEN THE OXYGEN MONITOR IS CORRECTLY INSTALLED AND MAINTAINED, IT MONITORS THE LEVEL OF OXYGEN IN ITS SURROUNDINGS 07/11
More informationSeries: MBC1-TC Mini Benchtop Temperature Controller
User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com
More informationBecause you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0
Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Manual v1.0 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE And neither are we. Always at the forefront of our industry, our
More informationPORTABLE AIR CONDITIONER OWNER S MANUAL
PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 JHS-A018-14KRH SKU#: 130009 WARNING: Read and follow all warnings
More informationHades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet
Notes: 1 Square = Foot/Feet Hades 2 Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. www.titancontrols.net Revision
More informationDICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:
KT6 Temperature Chart Recorder Contents: Instructions, Alarm Relays & Started / Accessories Calibration, Warranty / Factory Service & Order Form Temperature Ranges (user selectable): Recorder Accuracy:
More informationXaact Spot. Xaact Hot Spot
Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............
More informationOWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company
OWNER'S MANUAL FRY Holding Unit (FHU) Patent(s) Pending MODELS FHU FHU IMPORTANT INFORMATION, READ BEFORE USE. PLEASE SAVE THESE INSTRUCTIONS. This manual is Copyright 04 Duke Manufacturing Company. All
More informationPanel Mounted Heat Exchangers by Dantherm, Inc.
Panel Mounted Heat Exchangers by Dantherm, Inc. PRODUCT INFORMATION MANUAL C0028 003 Pinnacle OM Manual Rev AB Page 1 of 14 Dantherm, Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 Tel # +1 864
More informationIsotemp Explosion-Proof Refrigerators and Freezers
Isotemp Explosion-Proof Refrigerators and Freezers Refrigerator Model 153, 153HK Freezer Model 150, 150HK 104354 9/15/06 Table of Contents Safety Information...3 Alert Signals...3 Unpacking...4 Visible
More informationInstallation Instructions
P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat
More informationTable of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...
Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Setting the Timer... 6 Typical Loading System... 8 Section B Unit Maintenance... 9 Trouble Shooting
More informationWIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900
WIRING DIAGRAM This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900 17 THANK YOU! WARRANTY INFORMATION Thank you for choosing
More informationBecause you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL
Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationMax HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow all applicable
More informationGENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R
GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R OWNER S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
More informationREAD AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE
XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important
More informationREFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions
REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how to install,
More informationWatt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13
WATT-MUNCHER Portable Load Bank 6 June 2018 Simplex Service 800-637-8603 Page 1 of 13 This manual was last revised: 6 June 2018 For up-to-date information on this product or others, please contact Simplex
More information11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International
11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.
More informationInstruction Manual for the Revolutionary Science RS-IF-203 Incufridge
Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards 3 Operating
More information