Refrigerant Valves/Accessories
|
|
- Geoffrey Burns
- 6 years ago
- Views:
Transcription
1 Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating Temp. 60F To +240F To order, specify: type, flange connection, style and size Refrigerant Strainers for use in liquid lines, hot gas lines, suction lines and oil lines. SS screen 60 mesh Generous flow area Groove inlet, tongue outlet Safe working pres. = 400psig Installed as either separate or closed coupled unit To order, specify: catalog number, installed as either seperate or closed coupled unit, and if flanges are necessary (size & type) Piston Type Check Valves Flanged, heavy duty, piston type check valves for closure upon pressure reversals High flow capacity Manual opening stem Bonnet servicable Rugged design To order, specify: type, flange connection, style and size Refrigerant Float Switches Used to electrically indicate or control a liquid level Rugged 10 amp switching capacity Simple,direct switch pivot arm Optional switch housing heater Safe working 400psig Operating temp -50f to +150f
2 Refrigerant Liquid Level Indicators Features a reflex lens which appears dark in the presence of liquid and light when liquid is absent. Frost shield is an option. Asme sa36 housing material 3.25 Long universal housing Reflex lens standard Safe working 400psig Operating temp -60f to +240f Refrigerant Shut-Off Valves Rugged valves for industrial refrigeration featuring ball bearing swivel seats, no leak stem seal design and back seating for stem seal replacement. Using either handwheel or seal cap. Flanges ¼ to 1 ¼ using oval 2-bolt style 1 ½ to 4 size, uses 4-bolt square style To Order: Specify Flange Number Size, Flange Kit connection style and size.
3 Refrigerant Valves Refrigerant Solenoid Valves Designed for industrial refrigeration. High quality, compact, strong bodied and reliable. Spring closing with teflon seats Pressure drop is low One solenoid coil fits all valves 300psi MOPD 400psig safe working pressure Suitable of ammonia, R22, R134a, etc. -60F to +240f To order, specify the following: Type & Port Connection Style & Size Coil Connection Style Voltage Strainer
4 Refrigerant Hand Expansion Valves Featuring unique slotted plugs for accurate flow regulation along w/teflon seat discs for tight closing. Valve stems are stainless steel w/double seals to eliminate stem leakage. Defrost Controller Utilized for operation of various control valves and fan relays to quickly remove frost/ice accumulation from evaporator surfaces. Precision quartz clock 24Hour or 7 day scheduling 10AMP, SPDT relay Stepping button for trials NEMA 4 enclosure Refrigerant Gauge, Purge & Needle Valves Seal cap, bar handle or bare stem Stainless steel stem Plated forged steel body Non-removable safety stem Non-leak stem packing design Compact size For R22, R134a
5 Refrigerant Valves Refrigerant Pressure Regulators Designed for simple, reliable operation utilizing a series of easily changed modules(pilots) to determine regulating function(s). strong ductile iron or steel body disc-piston w/teflon seal ring V-port modulation for finer control Suitable for Ammonia, R22, R134a Safe working pressure of 400psig Temperature of 60F to +240F To order specify the following: Type & Port Connection Style & Size Voltage where applicable Special Variations Strainer if required Type Of Regulator Variations Special Variations (Pilots) On Regulators
Intelligent Refrigeration Solutions
Intelligent Refrigeration Solutions Stop Check Valves Suitable for all common refrigerants including R-717 (Ammonia), R-134a and others Temperature Range: -50 F to 240 F (-46 C to +116 C) Temperature Below:
More informationRESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES
SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationHYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Air separators B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS A. Section - Plumbing Piping Specialties B. Section
More informationHYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Air separators B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS A. Section - Plumbing Piping Specialties B. Section
More informationREFRIGERATION PRODUCTS
SE REFRIGERATION PRODUCTS Smart Electric products offer reliable and longer lasting solutions for refrigeration. We know how important it is to keep systems clean and running at its full efficiency for
More informationPeerless Pump Company
Peerless Pump Company HVAC & Hydronics Equipment Triple Duty Valves & Suction Diffusers Diaphragm Type Hydro-pneumatic Tanks Air Separators Automatic Air Eliminators Grundfos Inline Circulator Pumps Peerless
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationHYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS
More informationPULSE WIDTH MODULATING VALVES
PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum
More informationSalinas Valley Ammonia Safety Day. May 26, 2011 Salinas, CA
Salinas Valley Ammonia Safety Day May 26, 2011 Salinas, CA Basic Refrigeration By Russell Ramos, Sales Engineer, Joseph H. Schauf Co., Madera, CA What is the Big Picture for Today s Safety Seminar? To
More informationEssex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL
Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationPACKAGED AIR COOLED Product Data Catalog
PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES
More informationSpecifications, Applications, Service Instructions & Parts FROST MASTER & FROST MASTER PLUS DEFROST CONTROLLERS
Bulletin Specifications, Applications, Service Instructions & Parts FROST MASTER & FROST MASTER PLUS DEFROST CONTROLLERS for Industrial/Commercial Evaporator Defrosting FM-71 Defrost Controller INTRODUCTION
More informationReciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12
Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12 GENERAL The Powerex oil-less tank mounted system is designed to provide clean, dry air for industrial applications where the
More informationAUTO-PURGER AP. Noncondensible Gas (Air) Refrigerant Purger. Model APW OPERATOR INSTALLATION & INSTRUCTION MANUAL
AUTO-PURGER AP Noncondensible Gas (Air) Refrigerant Purger Model APW OPERATOR INSTALLATION & INSTRUCTION MANUAL For Models APC, AP01, AP08, AP16, AP24, and 'W' Versions TABLE OF CONTENTS Section 1 Mounting
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationIndustrial Refrigeration Defrost Solutions TM Package. Brochure R-222
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Industrial Refrigeration Defrost Solutions TM Package Brochure R- R-
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationPump & Trap Combinations
NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company
More informationSECTION AIR COMPRESSORS AND ACCESSORIES
PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and
More informationSECTION STEAM CONDENSATE PUMPS
SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although
More informationThe rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.
W1860BE.book Page 12 Tuesday, January 28, 2003 11:01 PM 2. Cooling System A: COMPRESSOR The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. As the rotor
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationEFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08
EFFECTIVE: MAY, 2008 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 021-0061 Model: ASQ Glasswasher American Dish Service
More informationOur Know-How. Your Peace of Mind. Steam Solutions
Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article
More informationINSTALLATION INSTRUCTIONS
,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE
More informationSECTION HEATING BOILER FEEDWATER EQUIPMENT
SECTION 23 53 00 HEATING BOILER FEEDWATER EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes boiler feedwater pumps, de-aerators, accessories, controls and tanks. 1.2 REFERENCES A. ASME (American
More informationFlow Control for Fire Protection
Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationwater source / fan coils
MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without
More informationSECTION 1 MOUNTING & PIPING INSTALLATION. INSTALLATION DIMENSIONS (MM) Figure 1
Bulletin Specifications, Applications, Service Instructions & Parts AUTO-PURGER M Energy Saver Compact, Non-condensible Gas (Air) Purger For Models APM & APMF Model APM SECTION 1 MOUNTING & PIPING INSTALLATION
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationAPT and APT14 Automatic Pump Traps. for effective condensate drainage and removal
APT10-4.5 and Automatic Pump Traps for effective condensate drainage and removal 1 An innovative solution for effective heat User benefits Self contained compact unit. Operates with 8 in. installation
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationSection H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS
Section H BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...................................................H- PRODUCT OFFERING.......................................................H- SAMPLE SPECIFICATIONS...................................................H-
More informationSECTION REFRIGERANT PIPING
SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationLiquid Drainers LIQUID DRAINERS
Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG
More informationModel 10AB/APRB Automatic Dishwasher
Model 10AB/APRB Automatic Dishwasher Rinse and Wash Head Assemblies ITEM 1 0126800 End Plug 2 0125000 Rinse Arm Body (only) 3 0126000 Nylatron Washer (2 places) 4 0125500 Hex Nut 5 0126500 Snap Ring 6
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationTEMPERATURE & PRESSURE CONTROLS
TEMPERATURE & PRESSURE CONTROLS RANCO LUBE OIL PROTECTION CONTROLS These lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure.
More informationFLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS
FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS Bulletin No. AY-780-L This bulletin should be used by experienced personnel as a guide
More informationT E C H N O L O G I E S P R O D U C T C A T A L O G
P R O D U C T C A T A L O G 2 0 1 0 IT S A VERY... COOL WORLD GENERAL INFORMATION The information contained in this catalog is correct at the time of publication. Henry Technologies has a policy of continuous
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / 11-14
SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More informationAUTO-PURGER M OPERATOR INSTALLATION & INSTRUCTION MANUAL. ENERGY SAVER Compact, Noncondensible Gas (Air) Purger ISO For 115V and 230V Models
AUTO-PURGER M ENERGY SAVER Compact, Noncondensible Gas (Air) Purger ISO 9002 Model APM OPERATOR INSTALLATION & INSTRUCTION MANUAL For 115V and 230V Models Bulletin APM-001d March, 1999 SECTION I MOUNTING
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationPowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois
Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 5 Explain the purpose and operation of
More informationHydrocarbon & Chemical Processing Solutions
Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly
More informationSECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.
SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.
More informationOPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F
OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationREPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES
PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES 0004 0002 0001 PRECISION WATER SYSTEMS WATER DISTILLER MANUFACTURED BY: PRECISION DESIGN & MANUFACTURING INC.
More informationOwner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service
Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationSECTION AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationFull-line Product Overview
Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available
More informationSECTION HYDRONIC PIPING AND SPECIALTIES
SECTION 15511 HYDRONIC PIPING AND SPECIALTIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Pipe Materials. 2. Fittings. 3. Specialty Items. 4. Glycol Antifreeze Protection. 5. Process Cooling B.
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA
More informationMCBV MOTOR CONTROLLED BALL VALVES
MCBV MOTOR CONTROLLED BALL VALVES STAINLESS STEEL for Industrial Refrigeration Applications, Capacities, Features, & Advantages HANTEMP MCBV (U.S. Patent # 9,518,665) Motor Controlled Ball Valves are gaining
More informationPT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.
PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC
More informationService Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only
Service Manual Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only Theory of Operation and Safety Precautions... 2 Component Descriptions... 3 Plumbing Diagram... 8 Pictorial Views...
More informationACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO
SECTION 210523 - GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationParts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-515MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71390 Issued: 10-23-2017 Revised: 11-17-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main
More informationUNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3
GENERAL: Hydronic systems included in this document are chilled water, heating hot water, dual temperature and glycol based systems. DESIGN GUIDELINES: Design General 1. Where campus steam is available,
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationDean Pump High Temperature Chemical Process Inline Pumps
Bulletin C-1.2.21. Dean Pump High Temperature Chemical Process Inline Pumps Series DL Dean Pump Series DL High Temperature Chemical Process Inline Pumps Capacities to 600 GPM (182 m 3 /hr) Heads to 0 feet
More informationRevolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability
Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability ETS Colibri brings to the market one of a kind, uniquely designed electric expansion valve. Innovative Design
More informationSporlan Valve Division Parker Hannifan/CIC Group
www.parker.com/cic Sporlan Valve Division Parker Hannifan/CIC Group Matt McGrath, SW Regional Sales Manager Bob Dolan, Sales Engineer - Atlanta www.parker.com/cic Why Discuss TEVs Today? Expansion Valves
More informationGlass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.
Glass Washer PERLICK Glass Washer 1 50567 Glasswasher Control 2 52536 Spray Arm Drive Motor 3 50445 Wash Pump 4 52528 Pump Motor Capacitor 5 52652-1 Water Inlet Valve 6 52669-1 Band Heater 7 52626A-B Rinse
More informationIndustrial Refrigeration. Brochure R/S CB 02/10
Industrial Refrigeration Brochure R/S CB 02/10 Page 2 Parker Industrial Refrigeration Group, Refrigerating Specialties and HERL, is the premier supplier to the food and beverage industry. We ve been the
More informationXSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationPROJ. NO SECTION REFRIGERANT PIPING
SECTION 23 23 00 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationUNIVERSAL STYLE STEAM TRAPS WU450 Series
Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,
More informationMYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationFloat & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment
Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most
More informationVent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI
Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,
More informationCHILLER. Operator s & Installation Manual
CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationBBSS BASIC BOTTLE SAMPLING SYSTEM
N BBSS BASIC BOTTLE SAMPLING SYSTEM The SENSOR Basic Bottle Sampling System (BBSS), is a closed loop liquid sampler that is ideal for processes with pressure less than 150 psig and process temperature
More informationREFRIGERANT PIPING SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.
More informationSECTION DOMESTIC WATER PIPING SPECIALTIES
SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUniversity of Delaware
SECTION 23 21 23_HYDRONIC PIPING SYSTEMS ABOVE GRADE PART 1 GENERAL 1.1 SUMMARY University Contact: Energy & Engineering Group (302) 831-1744 This standard includes hydronic piping requirements for both
More informationDiesel Exhaust Fluid Compatible Products DEF
Diesel Exhaust Fluid Compatible Products DEF Aboveground Installation Monitoring Cap & Adaptor 22 Vent 8 or 9 Anti-Siphon Valve or Solenoid Valve 24 Clock Gauge 29 Overfill Alarm Sensor 21 Overfill Shut-Off
More informationCommercial, Residential & Institutional Pumps, Tanks, & Accessories
Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted
More informationVALVES SECTION 15100
VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common
More informationTM Series. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationParagon. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationWallace & Tiernan Gas Feed Systems V2000 Chlorinator
Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators
More informationIMAGE V. Parts and Service Manual
IMAGE 0V Section II Parts and Service Manual (88B) CLARKE TECHNOLOGY Image Operator's Manual Page AUTHORIZED PERSONNEL MAINTENANCE To Access Pump Motor. Remove brush housing from machine. See "Brush Motor
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More information