1 LG LG New Wide Wired Remote Controller Owner's & Installation Manual Models: PQRCVSL0 PQRCVSL0QW IMPORTANT Please read this owner's & installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this owner's & installation manual for future reference after reading it thoroughly. P/No.: MFL690 ITALIANO ESPAÑOL FRANÇAIS DEUTSCH êìëëäàâ PORTUGUÊS

2 New Wide Wired Remote Controller Owner s & Installation Manual TABLE OF CONTENTS Safety Precaution... Part Description... Installation instruction... Group control...7 Installer Setting - How to enter installer setting mode...8 Installer Setting - Test Run Mode... Installer Setting - Setting Address of Central Control... Installer Setting - E.S.P.... Installer Setting - Thermistor... Installer Setting - Ceiling Height Selection...6 Installer Setting - Static ure Setting...7 Installer Setting - Remote Controller Master/Slave Setup...8 Installer Setting - Override Master/Slave Setting...9 Installer Setting - Dry Contact Mode Setting...0 Installer Setting - Zone State... Installer Setting - Celsius / Fahrenheit Switching... Installer Setting - Zone Type Setting... Installer Setting - Zone Number Setting... Installer Setting - Emergency Heater Setting... Installer Setting - Option Function Setting Standard Operation - Standard Cooling...8 Standard Operation - Power Cooling...9 Standard Operation - Heating Mode...9 Standard Operation - Dehumidification Mode...0 Standard Operation - Fan Mode...0 Standard Operation - Auto Operation Mode... Standard Operation - Temperature Setting/Room Temperature Check... Standard Operation - Airflow Setting... Sub function - Direct Wind / Indirect Wind... Sub function - Plasma Purification...6 Sub function - Humidifier...7 Sub function - Electric Heater...8 Sub function - Energy-Saving Cooling Operation...9 Sub function - Robot Cleaning Manual Setup...0 Function setting - Child Lock... Function setting - Robot Cleaning Automatic Setup... Function setting - Filter Sign Clear... Function setting - Elevation Grill... Function setting - Vane Angle Control... Function Setting - Change Temp...6 Function setting - Zone Control...7 Function setting - Changing Current Time...8 Function setting - Auto Cleaning...0 Programming - Simple Reservation... Programming - Sleep Reservation... Programming - ON Reservation... Programming - OFF Reservation... Programming - Weekly Reservation...7 Programming - Holiday Reservation...9 Ventilation Product User Manual - Interlinked Air conditioner and Ventilation...60 Ventilation Product User Manual - Interlinked operation with general ventilation...6 Manual Conversion - ing Ventilation button in ventilation mode will manually convert...6 Ventilation Product User Manual - Interlinked Operation with Direct Expansion Ventilation...6 Ventilation Product User Manual - Single Operation with Direct Expansion Ventilation...6 Ventilation Product Additional Operations - Fast / Power Saving...6 Ventilation Product Function Settings...66 Ventilation Product Reservations Settings...67 Ventilation Product Installer Setting Functions - Entering Method...68 Different mode drive...69 Checkups before reporting breakdown...70 New Wide Wired Remote Controller Safety Precaution Installation Be sure to request to the service center or installation specialty store when installing products. It will cause fire or electric shock or explosion or injury. Do not place flammable stuffs close to the product. It will cause fire. Request to the service center or installation specialty store when reinstalling the installed product. It will cause fire or electric shock or explosion or injury. Do not allow water to run into the product. It will cause electric shock or breakdown. Safety Precaution The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company. For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service. The following safety cautions are provided to prevent unexpected dangers or losses. WARNING : If the user does not follow the mandatory items, it may result in serious injury or death. CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property damage. : Warning and Caution are to call the user s attention to the possible danger. Read and follow them carefully in order to prevent a safety accident. : Warning and Caution are indicated in this guide and the product itself to help protect the users from danger. In-use Request to the service center or installation specialty store when the product becomes wet. It will cause fire or electric shock. In-use Do not clean using the powerful detergent like solvent but use soft cloths. It will cause fire or product deformation. WARNING Do not disassemble, fix, and modify products randomly. It will cause fire or electric shock. Do not give the shock to the product. It will cause breakdown when giving the shock to the product. Do not give the shock using sharp and pointed objects. It will cause breakdown by damaging parts. CAUTION Do not press the screen using powerful pressure or select two buttons. It will cause product breakdown or malfunction. Do not touch or pull the lead wire with wet hands. It will cause product breakdown or electric shock. Owner s & Installation Manual

3 Part Description Part Description Name and Function of Remote Controller Please attach the inform label inside of the door. Please choose proper language depend on your country. 6 OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON FAN SPEED BUTTON ON/OFF BUTTON OPRATION MODE SELECTION BUTTON 6 WIRELESS REMOTE CONTROLLER RECEIVER Some products don't receive the wireless signals. 7 AIR FLOW BUTTON 8 SUBFUNCTION BUTTON 9 FUNCTION SETTING BUTTON 0 VENTILATION BUTTON RESERVATION UP,DOWN,LEFT,RIGHT BUTTON To check the indoor temperature, press button. ROOM TEMPERATURE BUTTON SETTING/CANCEL BUTTON EXIT BUTTON Some functions may not be operated and displayed depending on the product type. Accessory Installation instruction Installation instruction. Please fix tightly using provided screw after placing remote controller setup board on the place where you like to setup. - Please set it up not to bend because poor setup could take place if setup board bends. Please set up remote controller board fit to the reclamation box if there is a reclamation box. - Install the product so as not to make a gap with the wall side and to prevent shaking after the installation.. Can set up Wired remote controller cable into three directions. - Setup direction: the surface of wall reclamation, upper, right - If setting up remote controller cable into upper and right side, please set up after removing remote controller cable guide groove. Remove guide groove with long nose. Reclamation to the surface of the wall Upper part guide groove Right part guide groove Connection Cable (EA, 0m) Screw ( EA) Owner's / Installation manual Inform label (8EA-8Languages) <Wire guide grooves> New Wide Wired Remote Controller Owner s & Installation Manual

4 Installation instruction. Please fix remote controller upper part into the setup board attached to the surface of the wall, as the picture below, and then, connect with setup board by pressing lower part. - Please connect not to make a gap at the remote controller and setup board s upper and lower, right and left part. - Before assembly with the installation board, arrange the Cable not to interfere with circuit parts. Installation instruction When separating remote controller from setup board, as the picture below, after inserting into the lower separating hole using screw driver and then, spinning clockwise, remote controller is separated. - There are two separating holes. Please individually separate one at a time. - Please be careful not to damage the inside components when separating. <Connecting order> Wall Side <Separating order> Wall Side Wall Side Wall Side Group control. When installing more than units of air conditioner to one wired remote controller, please connect as the right figure. If it is not event communication indoor unit, set the unit as slave. Check for event communication through the product manual. GND Signal wire V GND Signal wire When controlling multiple indoor units with event communication function with one remote controller, you must change the master/slave setting from the indoor unit. - Indoor units, the master/slave configuration of the product after completion of indoor unit power OFF and then ON the power after minutes elapsed sign up. - For ceiling type cassette and duct product group, change the switch setting of the indoor PCB. ON ON. Please connect indoor unit and remote controller using connection cable. V Signal GND Red Yellow Black 6 New Wide Wired Remote Controller Please check if connector is normally connected. Connecting cable Indoor Unit side CAUTION Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Installations must comply with the applicable local/national or international standards. Apply totally enclosed noncombustible conduit (metal raceway) in case of local electric & building code require plenum cable usage.. Please use extension cable if the distance between wired remote controller and indoor unit is more than 0m. CAUTION When installing the wired remote controller, do not bury it in the wall. (It can cause damage in the temperature sensor.) Do not install the cable to be 0m or above. (It can cause communication error.) When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation. If you install the extension cable in the opposite direction, the connector will not be connected. Specification of extension cable: # core shield or above # switch OFF: Master # switch ON: Slave (Factory default setting) - For wall-mount type and stand type product, change the master/slave setting with the wireless remote controller. (Refer to wireless remote controller manual for detail) When installing remote controllers to one indoor unit with event communication function, set the master/slave of the remote controller. (Refer to remote controller master/slave selection) When controlling the group, some functions excluding basic operation setting, fan level Min/Mid/Max, remote controller lock setting and time setting may be limited.. When installing more than wired remote controllers to one air conditioner, please connect as the right picture. When installing more than units of wired remote controller to one air conditioner, set one wired remote controller as master and the others all as slaves, as shown in the right picture. You cannot control the group as shown in the right for some products. Refer to the product manual for more detail. GND Signal wire V B Y R MASTER B Y R SLAVE <When simultaneously connecting sets of wired remote controller> When controlling in groups, set the master/slaver of the remote controller. Refer to Installer setting section on how to set master/slave for more detail. GND Signal wire V Owner s & Installation Manual 7

5 Installation instruction Installer Setting -How to enter installer setting mode CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. When you enter the setting mode initially, Function code is displayed on the bottom of the LCD screen. Function Code Some categories of the menu may not be displayed according to the function of the product, or the menu name may be different. Value <Installer Setting Code Table> ) General air-conditioner product Installation instruction No. Function Code Value Test Run 0 0:Set Address Setting 0 00~FF : Address <ESP Step> <ESP Value> <Example> 0:VeryLow 0 ~ 0:Low E.S.P. Value 0 0:Med 0:High Function Code ESP step ESP value 0:Very High 0:Remo Thermistor Ceiling Height 0 0 0:Indoor 0:TH 0:Low 0:Med 0:High 6 Static ure 06 0:Very High 0:V-H 0:F-H 0:V-L 0:F-L 7 Master Setting 07 00:Slave If only Plus series models 00 : Group setting 0:Master 0 : Single setting 8 Override Setting 08 00:Slave 0:Master 9 Dry Contact 09 00:Auto-Off 0:Auto-On 0 Release Min. Delay 0 0:Set Zone State 0:Variable 0:Fixed Celsius 00:Celsius Fahrenheit Switching 0:Fahrenheit (Optimized only for U.S.A) 00:Zone Controller Zone Type 0:Damper Controller Zone Number 0~0(Zone number) Select mode Setup Low Ambient Heating Operation Setup FAN Speed 00 : not use 0 : not use 0 : fan off Emergency Heater 8 0 : use : use compressor off(0 /-8 )/on( /- ) : fan on Setting : use compressor off( /- )/on(0 /- ) : use compressor off(0 /- )/on( /-9 ) 6 Plasma 0 7 Electric heater 8 Humidifier 9 Elevation Grill 0 Ventilation Kit Auxiliary Heater 00: Not Installed 0: Installed Some contents may not be displayed depending on the product function 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

6 Installation instruction ) General Ventilation product No. Function Code Value Test Run 0 0 : Test Run Setup Address Setting 0 00~FF : Address of Central Control SA(Supply Air) ESP 0 <ESP level> <ESP value> <Example> 0 : Low 0~ EA(Exhaust Air) ESP 0 0 : High 0 : Super High ESP step Function Code Product Direction 0 0 : Normal 0 : Opposite 6 Quick Refresh Priority 06 0 : Supply Air First 0 : Exhaust Air First 7 Master Setting : Slave 0 : Master 8 Override Setting : Slave 0 : Master 9 Dry Contact : Auto-Off 0 : Auto-On 0 Release Of Minute Delay 0 0 : Set Zone State 0 : Variable 0 : Fixed Humidification for Singular 00 : Not in Use Ventilation 0 : Use Humidification for Heat Mode 00 : Automatic Ventilation 0 : Manual Some contents may not be displayed depending on the product function ESP value Installer Setting -Test Run Mode After installing the product, you must run a Test Run mode. For details related to this operation, refer to the product manual. Function Code Set button to start. Installation instruction If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. - Please cancel the right and left of wind direction for RAC product. Setup figure '0' blinks at the lower part of indication window. During the test run, pressing the below button will exit the test run. - Select operation, temperature up/down, wind flow control, wind direction, start/stop button. 0 New Wide Wired Remote Controller Owner s & Installation Manual

7 Installation instruction Installer Setting - Setting Address of Central Control It's the function to use for connecting central control. Please refer to central controller manual for the details If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If entering into address setup mode by using button, it indicates as picture below. Set Group No. by pressing button.(0~f) Move to Indoor No. setting option by pressing button. Indoor No. Group No Function Code Installer Setting -E.S.P. If you set ESP incorrectly, the air conditioner may malfunction. This setting must be carried out by a certificated-technician. ESP value Function code, ESP code Installation instruction This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If entering into ESP setup mode by using button, it indicates as the picture below. ESP step Function Code ESP value Select ESP fan step by pressing button. (0: very low, 0: low, 0: medium, 0: high, 0: very high) Set Indoor No. by pressing button. Move to ESP value setting by pressing button. (It is 000 when delivering from the warehouse.) 6 7 button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. (It is possible to setup ESP value from to, and is the smallest and is the biggest.) button to setup ESP value. When setting ESP value on the product without very weak wind or power wind function, it may not work. New Wide Wired Remote Controller Owner s & Installation Manual

8 Installation instruction ESP value Function code, ESP code Select ESP fan step again by using 6 button and setup ESP value, as No. and, that corresponds each wind flow 7 8 button to save. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Installer Setting -Thermistor This is the function to select the temperature sensor to judge the room temperature. Installation instruction If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If moving to room temperature perception sensor selection menu by pressing button, it indicates as picture below. Please be careful not to change the ESP value for each fan step. It does not work to setup ESP value for very low/power step for some products. ESP value is available for specific range belongs to the product. Set Thermistor value by pressing button. (0: Remote Controller, 0: Indoor, 0: TH) Function Code Thermistor setting button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. <Thermistor Table> Temperature sensor selection Function 0 Remote controller Operation in remote controller temperature sensor 0 Indoor unit Operation in indoor unit temperature sensor 0 Cooling TH Operation of higher temperature by comparing indoor unit's and wired remote controller s temperature. (There are products that operate at a lower temperature.) Heating Operation of lower temperature by comparing indoor unit's and wired remote controller's temperature. The function of TH has different operation characteristics according to the product. New Wide Wired Remote Controller Owner s & Installation Manual

9 Installation instruction Installer Setting -Ceiling Height Selection This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If moving to ceiling height selection menu by pressing button, it indicates as picture below. Installer Setting -Static ure Setting button for seconds to enter the installer setting mode until timer segment displays 0:0. Installation instruction This function is applied to only duct type. Setting this in other cases will cause malfunction. If pressing button repeatedly, it moves to static pressure selection menu as picture below. Select ceiling height value by pressing button. (0:Low, 0:Medium, 0:High, 0:Very high) Select static pressure by pressing button. (0:V-H, 0:F-H, 0:V-L, 0:F-L) Function Code Thermistor setting button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Function Code ure button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. <Ceiling Height Selection Table> Ceiling Height Level Description 0 Low Decrease the indoor airflow rate step from standard level 0 Medium Set the indoor airflow rate as standard level 0 High Increase indoor airflow rate step from standard level 0 Very high Increase indoor airflow rate steps from standard level Ceiling height setting is available only for some products. Ceiling height of Very high function may not exist depending on the indoor unit. Refer to the product manual for more details. 6 New Wide Wired Remote Controller <Static ure Setting Table> ure selection Function Zone state ESP standard value 0 V-H Variable High 0 F-H Fixed High 0 V-L Variable Low 0 F-L Fixed Low Owner s & Installation Manual 7

10 Installation instruction Installer Setting-Remote Controller Master/Slave Setup It is a function for settings in group control, or -remote controller control. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to master/slave selection menu as picture below. Installer Setting - Override Master/Slave Setting Override master/slave selection function is, since Multi-V 7 series model, the function to prevent product's different mode operation. If it setup as the slave, It blocks to change opposite run mode to outdoor unit cycle (cooling/heating) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Installation instruction If pressing button repeatedly, it moves to override master/slave selection menu as picture below. Select Master/ Slave by pressing button. (00: Slave, 0: Master) Select Master/ Slave by pressing button. (00: Slave, 0 : Master) 8 New Wide Wired Remote Controller Function Code Master/Slave value button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Remote controller Function Master Indoor unit operates based on master remote controller at group control. (Master is set when delivering from the warehouse.) Slave Setup all remote controllers except one master remote controller to slave at group control Refer to the 'group control' part for details When controlling in groups, basic operation settings, airflow strength weak/medium/strong, lock setting of the remote controller, time settings, and other functions may be restricted. Function Code Master/Slave button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Override master/slave selection function is possible to use only when it is connected to the succeeding models of Multi-V 7 series. If it is set as Override Slave, icon is displayed on LCD Display Window. (See Figure ) Figure. Owner s & Installation Manual 9

11 Installation instruction Installer Setting-Dry Contact Mode Setting Dry contact function is the function that is possible to use only when dry contact equipment is separately purchased/setup. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to remote controller dry contact mode setup menu as picture below. Installer Setting - Zone State It is the function to setup indoor unit's wind flow to variable or fixed. - Variable : Comp ON, setup airflow. Comp OFF, weak wind - Fixed : Comp ON, setup airflow. Comp OFF, setup airflow If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Installation instruction If moving to ceiling height selection menu by pressing button, it indicates as picture below. Select Dry contact setting by pressing button. (00 : Manual, 0 : Automatic) Select Zone State rate fixing mode by pressing button. (0: Variable, 0: Fixed) Function Code Dry Contact setting value button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Function Code Zone State fixing mode button to save. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. What is Dry Contact? Like hotel card key and body perception sensor, it is the signal of the point of contact when using air-conditioner by interlocking. Please refer to dry contact manual for more details. 0 New Wide Wired Remote Controller Owner s & Installation Manual

12 Installation instruction Installer Setting-Celsius / Fahrenheit Switching This function is used for switching the display between Celsius and Fahrenheit. (Optimized only for U.S.A) If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. Function Code Ex) Fahrengeit Setting button to select conversion mode value Select Temperature unit mode by pressing button. (00: Celsius, 0: Fahrenheit) button to save or release. Installer Setting-Zone Type Setting Installation instruction This function is only available on some products. It is possible to setup zone new type or old one of the product which is available to install the damper controller. CAUTION If you set zone number incorrectly, the product may malfunction especially in zone control. This function must carried out by a certificated-technician. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. Function Code button to select Zone type value Ex) Setting the Zone Type as "New" Select Zone Type by pressing button (00:Old, 0:New) button to save or release. New Wide Wired Remote Controller button to exit or system will automatically exit after seconds without any input. Whenever press button in Fahrenheit mode, the temperature will increase/drop degrees. button to exit or system will automatically exit after seconds without any input. Owner s & Installation Manual

13 Installation instruction Installer Setting-Zone Number Setting This function is only available on some products. Zone Number is to set the number of installed zones. It's possible to control only in zone new type If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code. button to select Installer Setting- Emergency Heater Setting This function is only available on some products This function will set the Emergency Heater Setting. Emergency Heater is used to heat the space in emergency case such as heat pump error. Emergency heat is in place of and does not supplement heat pump. Emergency Heater setting Function sets following conditions: ) Emergency Heater operation while in error or outdoor unit operates cooling cycle. ) Emergency Heater operation in Low Ambient temperature ) Fan speed setting during Emergency Heater operation CAUTION This function setting must be carried out by a certified-technician. Incorrect function setting can cause fire. Installation instruction Function Code Zone Number installed Ex) Setting the Zone Number for "" Select Zone Number by pressing button (0~0 : number of zone installed) If pressing button long for seconds, it enters into remote controller setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. Repeat pressing Function code 8. button to select button to save or release. button to exit or system will automatically exit after seconds without any input. Setting : Low Ambient Heating Operation Setting : FAN Speed Setting during Emergency Heater Operation Setting : Heater Operation while in error or outdoor unit operates cooling cycle. Function Code Setting: Heater Operation while in error or outdoor unit operates cooling cycle. Select mode of Heater Operation while in error by pressing button 00: not use 0: use If 00 is set at this stage, setting & setting will not be available New Wide Wired Remote Controller Owner s & Installation Manual

14 Installation instruction Move to Low Ambient Heating Operation setting by pressing button. Installer Setting - Option Function Setting Installation instruction Setting feature for indoor unit when air cleaning / heater / humidifier / Up/down grill / Ventilation KIT /Auxiliary Heater is newly installed, or installed unit is removed. button to setup Low Ambient Heating Operation. 0 : not use : use - compressor off(0 / -8 ) / compressor on( / - ) : use - compressor off( / - ) / compressor on(0 / - ) : use - compressor off(0 / - ) / compressor on( / -9 ) Emergency heater operation in Low Ambient temperature - compressor off : Emergency heater enabled - compressor on : Emergency heater disabled Move FAN Speed Setting during 6 Emergency Heater Operation by pressing button. If pressing button long for seconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than seconds for sure. If pressing button repeatedly, it moves to the selected option function code as picture below. Select existing condition of each mode by pressing button. (00: not installed, 0 : installed) Function Plasma purification Electric heater Humidifier Elevation grill Ventilation kit Auxiliary heater Code 0 7 button to setup FAN Speed during Emergency Heater Operation. Function Code Existing condition button to save : fan off : fan on button to save. button to exit or system will automatically exit after seconds without any input. ing button will exit settings mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

15 Standard Operation - Standard Cooling It cools the room by comfortable and clean wind. button to turn on the indoor. Standard Operation - Power Cooling It makes the room cool using pleasant and fresh air quickly button to trun on the indoor. button to select cooling operation mode. button to select Cooling operation mode. button continuously until 'Po' displayed. Adjust the desired temperature by pressing buttons. button to check the Room temperature. When setting the desired temperature higher than room temperature, only ventilation wind is blow out instead of cooling wind. Setting Temp Range : 8 C~0 C (6 F~86 F) What is Power Cooling? Desired temperature: Po (actually 8 C) It make room temperature Wind flow: power wind } drop fast by running Wind direction: fix to air-cooling position Partial product has no power air-cooling function. Standard Operation - Heating Mode It supplies warm wind to the indoor indoor. button to turn on the Heating drive only operates at the cooling and heating model. Heating doesn't operate at cooling exclusive model. button to select Heating mode. (To check the indoor temperature, press the room temperature button.) Adjust the desired temperature by pressing buttons. When setting the desired temperature lower than room temperature, there is only ventilation wind. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

16 Standard Operation - Dehumidification Mode It removes humidity while air-cooling weakly. button to turn on the indoor. Standard Operation - Auto Operation Mode button to turn on the indoor. button to select Dehumidification mode. The temperature setting can not be adjusted during operation this mode. the button to select airflow rate feeble weak medium strong automatic. (The initial wind powerfulness of humidity removal drive is 'weak'.) button to select Artificial intelligence Mode. You can adjust the temperature as the picture on the right for cooling and heating model. In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively. The menu item of wind powerfulness might not be partially selected according to the product. Standard Operation - Fan Mode It blows the air as it is in the indoor, not the cold wind. indoor. Mode. button to turn on the button to select Fan During operating Auto Operation mode: We can use the FAN SPEED button We can change manually to other operation mode. For the case of cooling exclusive, as the picture on the right, you can adjust the temperature from hot to cold, from "-" to "" based on "00". When cold When cool When appropriate When warm When hot Every time pressing button, you can select wind flow in order of Very Low Low Medium High Very High. When running ventilation, compressor of AHU doesn't work. Ventilation drive does not release cool wind but general fan Because it releases the wind that has no temperature difference from the room, it functions to circulate the inside air. The menu item of wind powerfulness might not be partially selected according to the product. 0 New Wide Wired Remote Controller Owner s & Installation Manual

17 Standard Operation - Temperature Setting/Room Temperature Check Temperature Setting We can simply adjust the desired temperature. the buttons to adjust the desired temperature. : Increase Temp. per one time pressing : Decrease Temp. per one time pressing Room temp: Indicate the current room temperature. Set temp: Indicate the temperature that user want to set. Standard Operation - Airflow Setting Wind powerfulness : You can simply adjust desired wind powerfulness. Please setup desired wind powerfulness by wind powerfulness button. Every time you press wind powerfulness, you can select the wind flow in order of feeble weak weak medium medium medium strong strong power automatic. The menu item might not be partially selected according to product function. Please refer to product manual for product s detailed function. Cooling operation: - The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature. Heating operation: - The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature. Room Temperature Check Whenever press button, the room temperature will be displayed within seconds. After seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different Wind direction : You can simply adjust desired wind direction. Please set desired wind direction by pressing button. You can select wind direction of (comfortable wind Up/Down and Right/Left Right/Left Up/Down) by pressing button. Partial item of wind directions might not be selected according to product function. Please refer to product manual for product s detailed function. For air-cooling drive, from 8 C to 0 C, and for heating drive, from 6 C to 0 C, you can select desired temperature. C is proper for the difference between room and outside temperature. New Wide Wired Remote Controller Owner s & Installation Manual

18 Sub function - Direct Wind / Indirect Wind It is the function to directly or indirectly control wind direction by body perception sensor. The method to setup direct/indirect wind Please press button. The icon of direct/indirect wind blinks on the display, and then, if pressing button, direct/indirect wind icon is fixed and the function is setup. direct wind Please press button. The icon of direct/indirect wind blinks on the display, and then, if pressing button, direct/indirect wind icon is removed and the function is cancelled. The method to cancel direct/indirect wind If pressing button, it gets out of setup mode. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. indirect wind If pressing button, it gets out of setup mode. direct wind indirect wind Direct/indirect wind function is additional function and it might not be indicated or operated at the partial product. Direct/indirect wind function is possible only when product is running. New Wide Wired Remote Controller Owner s & Installation Manual

19 Sub function - Plasma Purification Only products with humidifying function can use this. Sub function - Humidifier Only products with humidifying function can use this. The method to setup cleaning air Repeat pressing until icon flash. button Operate or cancel Plasma Purification function by pressing button. ( icon appears/disappears on display part up to selection ) After setting, press to exit. button After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Repeatedly pressing until icon flash. button Turn on/off HUMIDIFIER by pressing button (The icon will be displayed in case of SETTING option and disappear in reverse case.) Humidification function might not be operated at the partial product. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Cleaning air function is additional function and it might not be indicated or operated at the partial product. Cleaning air function is possible only when product is running. If you want independent cleaning air drive, please setup cleaning air by pressing additional drive button at ventilation drive. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

20 Sub function - Electric Heater It is a function to strengthen the heating ability by turning on the electric heater during the heating operation. It can only be set during heating operation. Repeatedly pressing until icon flash. button Turn on/off ELECTRIC HEATER by pressing button (the icon will be displayed in case of SETTING option and disappear in reverse case.) button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing button, the manipulated value is not reflected. Heater function is additional function and it only operates in selected models. The indoor unit product with Auxiliary Heater function set automatically displays (0) icon during the AUXILIARY HEATING OPERATION. Sub function - Energy-Saving Cooling Operation Power saving air-cooling function is the function to improve use's comfortableness and power saving capacity by adjusting desired temperature while running air-cooling Repeatedly pressing until icon flash. button Operate or cancel Energy-Saving function by pressing button. (To cancel power saving function, you move to power saving menu by pressing button, and then if pressing button, power saving icon disappears and the function is cancelled. ) button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. When using non-heat recovery out door unit, emergency heater can be turned on for simultaneous heating and cooling. Indoor unit with the emergency heater must be turned OFF for simultaneous cooling and heating Heater function is additional function and it only operates in selected models. Emergency heater can be turned on while in error code in case of emergency. Electric heater icon is displayed on LCD display window with error code when emergency heater is on while in error Exception case: Error code,,9,0 If the previous mode of the Indoor unit is COOL, DRY or FAN ONLY mode, heater must be turned on manually. Power saving function is possible to setup only when running air-cooling. Power saving function might not be operated at the partial product. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

21 Sub function - Robot Cleaning Manual Setup Robot cleaning function is the function for cleaner attached to the product to automatically clean the filter when using air-conditioner for the specific period of time. Repeatedly pressing until icon flash. button Function setting - Child Lock It is the function to use preventing children or others from careless using. button repeatedly until the is flashing. Turn on/off Smart Clean function by pressing button. When the cleaning is finished, the smart cleaning display disappears automatically. To cancel robot cleaning manual setup function, you move to power saving menu by pressing button, and then if pressing button, "robot cleaning" icon disappears and the function is cancelled. After setting, press button to exit. Robot cleaning manual setup function might not be operated at the partial product. When exiting without pressing set button, the manipulated value is not reflected. If moving to 'setup' icon area by using button, 'setup' icon blinks, and child lock function is setup if pressing button at that time. When cancelling lock function, if moving to 'cancel' icon by pressing button and then, pressing button, child lock function is cancelled. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. 0 New Wide Wired Remote Controller Owner s & Installation Manual

22 Function setting - Robot Cleaning Automatic Setup Robot cleaning function is the function of cleaner attached to the product to automatically clean filter when using air-conditioner for the specific period of time. Set manual or automatic mode of smart cleaning. button repeatedly until the is flashing. When the flashing, press button to set/clear this function. Function setting - Filter Sign Clear This function is to clear the indicator of indoor filter cleaning. button repeatedly until the is flashing. When the is flashing, press the to clear this display Set state : Enable Auto Smart Clean function When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more electric power. Therefore. do clean the filter whenever cleaning time is expired. Clear state : Disable Auto Smart Clean function Filter cleaning indication is automatically cancelled without the separate cancellation after certain period of time. When returning to manual robot cleaning, manual function is cancelled if moving to 'manual' icon by pressing Right/Left button and then, pressing button. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. Robot cleaning function is an additional function of the product and might not be operated at the partial product. New Wide Wired Remote Controller Owner s & Installation Manual

23 Function setting - Elevation Grill This function is to move the indoor filter up/down for cleaning filter. button Repeat pressing icon flash. button until Move to descent using button and press button will display descent icon and the up/down grill will descent. When up/down grill descents to the desired position, move to stop icon suing button and press button to stop up/down grill. When filter cleaning is finished, fix the filter to the up/down grill, move to ascent icon using button, and press button to ascent up/down grill. button to exit. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. Elevation grill function only operates in the indoor unit with the elevation grill. Function setting - Vane Angle Control This function is to adjust angle at which airflow is blow out. Repeat pressing icon flash. button until button to select active vane : / / / / All / Standard Select Vane number using buttons. Vane number : No.,.,,, all, or standard - Selected vane is in operation. - Please verify the operating vane. - To set the angle of all the vanes, select 'all'. - To set as the factory default settings, select 'standard'. Select wind angle using button, and press button. - The boundary of wind angle settings can be changed to levels or 6 levels according to the product. - When selecting 'standard' for Vane number, the wind angle does not move. Set the wind angles for the remaining vanes as the same as above. There are products with vanes with no. and no. only according to the product types. button to exit. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. button to complete and 6 active the setting process. (Airflow direction function will be released whenever setting vane angle) 7 button to exit or system will automatically release without any input after seconds. New Wide Wired Remote Controller Owner s & Installation Manual

24 Function Setting - Change Temp Change temperature is the function to setup air-cooling and heating drive automatically changeable according to the temperature at artificial intelligence drive mode. Repeat pressing icon flash. button until Function setting : Zone Control To turn on/off the zones by used of it Repeat pressing icon flash. button until Ex) Turn on the zone and zone. button to change. Converting temp value : ~7 button to select the zone that which one you want to turn on/off. button to complete and active the setting process. button to turn on/off zone. button to exit or system will automatically release without any input after seconds. When exiting without pressing set button, the manipulated value is not reflected. button To select other zones If you want. Then, button to turn on/off that zone as mentioned above button to exit or system will automatically release without any input after seconds. When exiting without pressing set button, the manipulated value is not reflected. 6 New Wide Wired Remote Controller Owner s & Installation Manual 7

25 Function setting - Changing Current Time Please press function setup button. If pressing function setup button repeatedly, it moves to time setup menu. Time setup icon is indicated at that time and date blinks at current time indication area. Ex) Changing Current Time as 'Monday / AM 0:0'. day. key to adjust the current 7 button to move to 'Minute' setting mode. (the 'Minute' segment will flash) Setting Minute value by pressing 8 button. key to move to AM/ PM setting mode (the 'AM/ PM segment will flash). 9 button to finish. Setting AM/ PM value by pressing button. button to move to 'Hour' setting mode. (the 'Hour' segment will flash) 0 In the process, press button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting) When exiting without pressing set button, the manipulated value is not reflected. Setting Hour value by pressing 6 button. 8 New Wide Wired Remote Controller Owner s & Installation Manual 9

26 Function setting - Auto Cleaning The method to setup Automatic Drying Please press button. Move to automatic drying menu by pressing button twice. 'Automatic Drying' icon will be displayed and the current status, 'DISABLE' will blink. Programming - Simple Reservation You can set the reservation conveniently in the units of hour from hour to 7 hours. button to enter the Programming mode. (the segment flashing) Ex) Setting Simple Reservation time as ''. time. button to adjust reservation button to finish setting. If moving to ABLE icon area by using button, ABLE icon blinks, and automatic dry function is setup if pressing button at that time. button to exit. After setup, it automatically gets out of setup mode if there is no button input for seconds. When exiting without pressing set button, the manipulated value is not reflected. When returning to automatic dry no use, automatic dry function is cancelled if moving to DISABLE icon by pressing button and then, pressing button. If pressing button, it gets out of setup mode. After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. When exiting without pressing set button, the manipulated value is not reflected. When simple reservation setup, product automatically runs or stops after the time that is set. Automatic dry function might not be operated at the partial product. 0 New Wide Wired Remote Controller Owner s & Installation Manual

New Wide Wired Remote Controller

New Wide Wired Remote Controller LG LG New Wide Wired Remote Controller Owner's & Installation Manual Models: PQRCVSL0 PQRCVSL0QW IMPORTANT Please read this owner's & installation manual completely before installing the product. Installation

More information

SIMPLE WIRED REMOTE CONTROLLER

SIMPLE WIRED REMOTE CONTROLLER OWNER S & INSTALLATION MANUAL SIMPLE WIRED REMOTE CONTROLLER Please read this manual carefully before operating your set and retain it for future reference. ENGLISH ITALIANO ESPAÑOL FRANCAIS DEUTSCH PORTUGUESE

More information

Weekly Wired Remote Controller

Weekly Wired Remote Controller LG LG Weekly Wired Remote Controller Owner's & Installation Manual Models: PVRCUSZ0 IMPORTANT Please read this installation manual completely before installing the product. Installation work must be performed

More information

Weekly Wired Remote Controller

Weekly Wired Remote Controller LG LG Weekly Wired Remote Controller Owner's & Installation Manual Models: PCRCUSZ0 PDRCUSZ0 IMPORTANT Please read this installation manual completely before installing the product. Installation work must

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE: Vertical Air Handling Unit P/NO : MFL65003202

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL42262831 www.lg.com ITALIANO ESPAÑOL FRANCAIS

More information

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN USER S MANUAL Wired Remote Controller MWR-WS00 DEUTSCH PORTUGUÊS ENGLISH ITALIANO FRANÇAIS ESPAÑOL System Air Conditioner RUSSIAN EΛΛHNIKA E S F I P D G R A DB98-25179A(1) Safety Precautions Before using

More information

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...

More information

Air Conditioner. User manual. Wired remote controller MWR-WE11N

Air Conditioner. User manual. Wired remote controller MWR-WE11N Air Conditioner User manual Wired remote controller MWR-WE11N Thank you for purchasing this Samsung Product. Before operating this unit, please read this user manual carefully and retain it for future

More information

MA Remote Controller PAR-31MAA

MA Remote Controller PAR-31MAA English Deutsch CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-MAA Simple Operation Manual Français Español Italiano Nederlands Português Türkçe eský Slovenský

More information

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product. Wired Remote Control MWR-WE10 Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. EN ES FR IT PT DE EL NL PL HU RU AR DB98-32810A-09 Contents Preparation

More information

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E OPERATION MANUAL FOR USER For safe and correct use, please read this operation manual thoroughly before

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. FRANÇAIS OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : CEILING CONCEALED DUCT www.lg.com P/NO : MFL68120702 2 TIPS

More information

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : FLOOR STANDING ENGLISH FRANÇAIS ITALIANO ESPAÑOL ESPAÑOL DEUTSCH P/NO

More information

OPERATING MANUAL UTY-RNNYM P/N English

OPERATING MANUAL UTY-RNNYM P/N English OPERATING MANUAL English UTY-RNNYM P/N9373329206-04 OPERATING MANUAL CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER... 6

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION! CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 3 TIMER FUNCTIONS... 5 ON/OFF TIMER... 5 WEEKLY TIMER... 6 TEMPERATURE SET BACK TIMER... 8 FILTER DISPLAY RESET...

More information

Indoor Unit (2 Series)

Indoor Unit (2 Series) Indoor Unit (2 Series) Type: Ceiling Concealed Duct- High Static LG ENGLISH FRANÇAIS ESPAÑOL IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room

More information

HEAT & COOL MODEL (REVERSE CYCLE)

HEAT & COOL MODEL (REVERSE CYCLE) OPERATING MANUAL HEAT & COOL MODEL (REVERSE CYCLE) AIR CONDITIONER Duct Type Indoor Unit ARTG09LL ARTG12LL ARTG18LL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379439 CONTENTS SAFETY PRECAUTIONS... 1

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring

More information

Indoor Unit (2 Series)

Indoor Unit (2 Series) System Indoor Unit (2 Series) OWNER'S MANUAL Type: Wall mounted LG ENGLISH FRANÇAIS ESPAÑOL IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room

More information

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1 Air conditioner User manual Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M Thank you for purchasing this Samsung Product. Before operating this unit, please read this user manual carefully and retain

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

Air Conditioner. installation manual. imagine the possibilities. Wired Remote Control MWR-WE10. Thank you for purchasing this Samsung product.

Air Conditioner. installation manual. imagine the possibilities. Wired Remote Control MWR-WE10. Thank you for purchasing this Samsung product. Control MWR-WE10 Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. E S F I P D G R A DB98-32811A(2) Safety Information This installation manual

More information

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : CEILING CONCEALED DUCT MODEL : B42AWYN7G5A / B42AWYU4G5A B55AWYN7G5A

More information

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. THIS PRODUCT

More information

C&H NORDIC Commercial 4 SERVICE MANUAL

C&H NORDIC Commercial 4 SERVICE MANUAL C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...

More information

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series PORTUGUÊS ENGLISH ITALIANO ESPAÑOL FRANÇAIS ERV (Energy Recovery Ventilator) DEUTSCH E S F I P D DB98-27512A(3)

More information

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No. AIR CONDITIONER OPERATING MANUAL Duct type Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE PART No. 98067 98067_OM_EN.indd 07-Aug-5 :40:5 OPERATING MANUAL PART No. 98067

More information

OWNER S MANUAL VMH 09/12/18/24

OWNER S MANUAL VMH 09/12/18/24 OWNER S MANUAL VMH 09/12/18/24 Version C Inverter Single Zone Ductless Mini-Split Heat Pump Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com VMH Inverter

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL57942717 www.lg.com 2 TIPS FOR SAVING ENERGY

More information

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS OWNER S MANUAL High-Wall Fan Coil Unit Page GENERAL 2,3 OPERATING MODES 2 REMOTE CONTROL 2 OPERATION 3-9 REMOTE CONTROL OPERATION 3 INDOOR UNIT DISPLAY 5 EMERGENCY OPERATION 5 PRESSING THE ON/OFF BUTTON

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

40KMC KMQ

40KMC KMQ 40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier

More information

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions

More information

LG Concealed Duct Air Conditioner OWNER'S MANUAL

LG Concealed Duct Air Conditioner OWNER'S MANUAL Visit us at http://www.lgservice.com LG Concealed Duct Air Conditioner OWNER'S MANUAL LG Dear Owner Thank you for installing LG Air Conditioner. Your best choice guarantees you a great performance and

More information

WIRED REMOTE CONTROLLER

WIRED REMOTE CONTROLLER WIRED REMOTE CONTROLLER OPERATION MANUAL BRCE6 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure

More information

Installation and Owner s Manual

Installation and Owner s Manual WIRED REMOTE CONTROLLER Installation and Owner s Manual MODEL: KJR-120G1/TFBG-E(5V)(For high wall models) KJR-120G2/TFBG-E(12V) (For Duct/Cassette/Floor ceiling models) IMPORTANT NOTE: Read this manual

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

SU MO TU WE TH FR SA AM PM

SU MO TU WE TH FR SA AM PM OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO AIR CONDITIONER CONCEALED CEILING TYPE Français English AM PM Español KEEP THIS MANUAL FOR FUTURE REFERENCE CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR

More information

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Utopian Split A/C. Thank you for purchasing this quality Split A/C system! Utopian Split A/C Thank you for purchasing this quality Split A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any operation

More information

Compact Cassette Type

Compact Cassette Type Compact Cassette Type PART NO.9374379392-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 3 PREPARATORY OPERATION... 4 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER...

More information

Buttons on remote controller

Buttons on remote controller Buttons on remote controller 1 2 3 4 5 2 1 6 7 3 8 5 6 4 7 10 8 10 15 15 ON/OFF button button MODE button SWING button FAN button Introduction for icons on display screen button TIMER OFF button CLOCK

More information

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM OPERATING MANUAL AIR CONDITIONER CASTE TYPE AUT Series AM PM 6 9 5 8 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9704 CONTENTS SAFETY PRECAUTIONS... NAME OF PARTS... PREPARATORY OPERATION...

More information

Variable Refrigerant Flow (VRF) System Simple Touch Remote Control SAFETY WARNING

Variable Refrigerant Flow (VRF) System Simple Touch Remote Control SAFETY WARNING User Guide Variable Refrigerant Flow (VRF) System Simple Touch Remote Control Model Numbers: TVCTRLTWR0002T TVCTRLTWR0002A SAFETY WARNING Only qualified personnel should install and service the equipment.

More information

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3 EN SERVICE MANUAL UNI SPLIT SERIES ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3 Original instructions IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning

More information

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series ENGLISH FRANÇAIS ESPAÑOL Split - type Air Conditioner (Cooling and Heating) E S F DB98-27559A(1) Contents PREPARATION Safety

More information

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps 2011 Lennox Industries Inc. Dallas, Texas, USA 506789 01 08/2011 MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps This manual is the property of the homeowner and must be left with the

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS SAFETY PRECAUTIONS 3 PARTS NAMES 5 OPERATING TEMPERATURE 6 MANUAL OPERATION 7 ADJUSTING AIRFLOW DIRECTION 8 HOW THE AIR CONDITIONER WORKS

More information

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control) 42XQ 42XQA 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control) Thank you for choosing Carrier! You can be sure that

More information

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Standard / Standard Libero Artcool Mirror

More information

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE Emerson Blue Wireless Comfort Interface - Homeowner User Guide Message to Homeowners Congratulations on choosing the Emerson Blue

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

13500 BTU RV Air Conditioner Installation and Operating Instructions

13500 BTU RV Air Conditioner Installation and Operating Instructions 13500 BTU RV Air Conditioner Installation and Operating Instructions Model No.:HCB-R135-A-ID HCB-R135-A-OD 3092402 V140804 Thank you for choosing a Soleus Air RV Air Conditioner. This owner s manual will

More information

Programmable Thermostat

Programmable Thermostat Set & $ave Programmable Thermostat Installation and Operation Manual English Model 44360 Form# 42710-01 20091204 2009 Hunter Fan Co. 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling

More information

INSTALLATION MANUAL AIR CONDITIONER

INSTALLATION MANUAL AIR CONDITIONER ENGLISH FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national

More information

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS VENSTAR FAN COIL THERMOSTAT FAN COIL THERMOSTAT T1075 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS 3 Occupied, 1 Unoccupied Override capable 3 speed fan control Auto 2-pipe changeover when used with accessory

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution...1 1.2 Warning...1

More information

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No.: PS08-01 PS10-01 Ref: KY80 KY100 8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable

More information

Installation Instructions

Installation Instructions P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat

More information

Operating Instructions High-spec Wired Remote Controller

Operating Instructions High-spec Wired Remote Controller Operating Instructions High-spec Wired Remote Controller Model No. CZ-RTC Installation Instructions Separately Attached. ENGLISH Before operating the unit, read these operating instructions thoroughly

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat commercial SCHOOL THERMOSTAT T2900SCH MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Energy Saving Operation Morning Warm-up Period Programmable Override Unoccupied until button press

More information

User s Manual

User s Manual 997-060180-4e User s Manual 8403-060 Menu Driven Display 1120-445 I. CONTROLLER OPERATION ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode) 1. Before you can adjust the temperature,

More information

VIGÖR HRV PLUS AND VIGÖR ERV

VIGÖR HRV PLUS AND VIGÖR ERV User Guide VIGÖR HRV PLUS AND VIGÖR ERV VB0147 Model no. 44202 (with top ports) VB0149 Model no. 44212 (with top ports) VB0148 Model no. 44203 (with side ports) VB0150 Model no. 44213 (with side ports)

More information

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the

More information

HEAT COOL. Meets Commercial California Title 24

HEAT COOL. Meets Commercial California Title 24 Digital Thermostat commercial THERMOSTAT T2900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands

More information

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE High Static High Static 3 Phase High Static Bulkhead Type Slimline Type ARTG30L ARTC36L ARTC30L ARTF18L ARTA24L ARTG36L ARTC45L ARTA30L ARTG45L ARTC54L

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference. OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS

More information

Operating Functions Temperature Parameters

Operating Functions Temperature Parameters Operating Functions Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb) Fundamental Functions After powered on, no matter when the compressor is started, the time interval

More information

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International 12,000 BTU Portable Air Conditioner Operating PE3-12R-03 Instructions 3092402 Model No. PE3-12R-03 2010 Soleus Air International Thank you for choosing a Soleus Air PE3-12R-03 Portable Air Conditioner.

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED Indoor Unit M09AWNNB11 M12AWNNB11 R09AWNNB11 R12AWNNB11

More information

Portable Air Conditioner

Portable Air Conditioner Owner s Manual Portable Air Conditioner Model PCMB-12000E / PCMB-12000EH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in

More information

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V User Guide HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+ VB0124 VB0125 VB0127 PLEASE READ AND SAVE THESE INSTRUCTIONS. These products earned the ENERGY STAR by meeting strict energy

More information

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product. USER MANUAL Portable Air Conditioner and Heater With Heat Pump Technology PAC12 PAC15 PAC18 Please read this manual carefully prior to operating the product. TABLE OF CONTENTS INTRODUCTION... 3 IMPORTANT

More information

Installation and Owner s Manual

Installation and Owner s Manual WIRED REMOTE E CONTROLLER Installation and Owner s Manual MODEL: WC 20G Mode - + Fan speed (Lock) IMPORTANT NOTE: Read this manual carefully before installing or operating your wired remote controller.

More information

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions 3092402 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner

More information

14,000 BTU Portable Air Conditioner 12,000 BTU Heat Pump LX-140 / LX-140BL Operating Instructions Model No. LX-140 2006 Soleus Air International Thank you for choosing a Soleus Air LX-140/LX-140BL Portable

More information

SAT-3 Room Temperature Controller

SAT-3 Room Temperature Controller SAT-3 Room Temperature Controller USER S OPERATING INSTRUCTIONS Contents Introduction 5 Features Summary 5 Operation 7 On/Off 7 Room Temperature Adjustment 7 Operating Mode Selection 8 Fan Speed Selection

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL42262854 www.lg.com ITALIANO ESPAÑOL FRANCAIS

More information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Ceiling Cassette - 2Way http://www.lghvac.com

More information

Ducted air conditioner Operating Manual

Ducted air conditioner Operating Manual KLIMA Ducted air conditioner Operating Manual Note: Before using the Air Conditioner please read the safety instructions to ensure correct operation of the unit. 1 CONTENTS 1. Safety precautions---------------------------------------------------------------------------3-4

More information

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. Owner, s Manual AIR CONDITIONER Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference. CONTENTS 1. Safety Precaution-------------------------------------------------------------------------------1

More information

Operation Manual - PC-ARF - P IMPORTANT:

Operation Manual - PC-ARF - P IMPORTANT: Operation Manual - PC-ARF - MODE SPEED LOUV. TEMP HIGH LOUV.? IMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRED REMOTE CONTROL SWITCH. KEEP THIS MANUAL FOR FUTURE REFERENCE. P5414986 TC-12001

More information

LG Room Air Conditioner

LG Room Air Conditioner website http://www.lgservice.com LG Room Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity

More information

HEAT CONTROLLER, INC.

HEAT CONTROLLER, INC. HEAT CONTROLLER, INC. Wall Mounted Mini - Split System DMC24DB-1, DMH24DB-1 DMC36TB-1, DMH36TB-1 Dual-Zone, Tri-Zone Air Conditioning / Heat Pump Important Information Please read carefully and thoroughly

More information

Evolution Control. Zone Control Homeowner s Guide

Evolution Control. Zone Control Homeowner s Guide Evolution Control Zone Control Homeowner s Guide CONGRATULATIONS! Your decision to choose the Bryant Evolution Control puts you in a select group of homeowners who understand the value of precise comfort

More information

Set & $ave. Model Programmable Thermostat. installation and operation manual

Set & $ave. Model Programmable Thermostat. installation and operation manual Set & $ave Programmable Thermostat installation and operation manual Model 44110 42707-01 8-21-06 2 Table of Contents Important Information... 5 Tools... 6 Uninstalling the Existing Unit... 7 Installing

More information

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color. TDU Series LCD Thermostat Models Model # Temp RH CO2 Color TDU10-100 TDU10-101 TDU10-102 TDU10-103 grey LCD white enclosure TDU10 Series Model # Temp RH CO2 Color TDU40-100 TDU40-101 TDU40-102 TDU40-103

More information

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight

More information

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS: Welcome Thank you for purchasing the new Portable Air Condition SY-AC1200. Read this instruction booklet carefully in order to benefit fully from this product. Store the user manual in a safe place for

More information

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series FRANÇAIS ENGLISH ESPAÑOL Split-type Air Conditioner (Cooling and Heating) E S F DB98-27555A(1) Safety Precautions Register your product

More information

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International 14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions 3092402 Model No. LX-140 2012 Soleus Air International Thank you for choosing a Soleus Air LX-140 Portable

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER Model: PEL00460 1 CONTENTS Page No. Details 2 Important Safety Information 3 Product Overview 3 Positioning & Installation 4 Installation Errors 4 Control Panel 5 Screen IMPORTANT

More information