CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS."

Transcription

1 SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...7 CIRCUIT DIAGRAM...9 INDOOR PCB CIRCUIT DIAGRAM... OUTDOOR PCB CIRCUIT DIAGRAM...5 ERROR CONTENTS... DISASSEMBLY ILLUSTRATION... PARTS LIST...8 STANDARD ACCESSORIES...

2 SPECIFICATIONS TYPE COOLING & HEATING INDOOR UNIT AUU8RCLX AUURCLX AUU6RCLX OUTDOOR UNIT AOU8RLX AOURLX AOU6RLX COOLING CAPACITY HEATING CAPACITY 7,800 / 7,800 BTU/h,500 /,500 BTU/h,00 /,00 BTU/h,00 /,00 BTU/h,00 /,500 BTU/h 8,00 / 7,600 BTU/h AUURCLX AOURLX,700 /,700 BTU/h 7,800 / 6,800 BTU/h ELECTRICAL DATA POWER SOURCE 0 / 08 V 60Hz RUNNING CURRENT COOLING HEATING 7.0 / 7.8 A 9. / 0. A 8.9 / 9.9 A 0. /. A 8. / 9.5 A 6. / 7.9 A 0. /.7 A 9. /.0 A INPUT WATTS COOLING HEATING.6 /.6 kw.0 /.0 kw.05 /.05 kw.7 /.7 kw. /.08 kw.7 /.7 kw.66 /.5 kw.9 /.7 kw E.E.R. COOLING HEATING. /. kw/kw.0 /.0 kw/kw.07 /.07 kw/kw.00 /.00 kw/kw.7 /.0 kw/kw.00 /.95 kw/kw.67 /.7 kw/kw.9 /. kw/kw STARTING CURRENT 8. A 9.5 A 0 A 5 A MOISTURE REMOVAL ( /hr).5 L/hr.0 L/hr.0 L/hr 5.5 L/hr AIRCIRCULATION-Hi (m /hr) 950 m /hr,050 m /hr,600 m /hr,700 m /hr COMPRESSOR TYPE Total enclosed type, poles, Inverter, Twin Rotary Hermetic type, 6 poles, Inverter, Scroll DISCRIMINATION TNB0FPBM9 ANBFCMMT REFRIGERANT R0A lb oz,900 g lb oz,900 g lb oz,00 g 7lb 8oz,00 g FAN MOTOR DISCRIMINATION MFA-RPT MFA-RPT MFA-5PZM MFA-5PZM INDOOR UNIT ( Cool / Heat ) HIGH-SPEED MED-SPEED LOW-SPEED 50 / 00 r.p.m. 90 / 50 r.p.m. 0 / 0 r.p.m. 90 / 0 r.p.m. 0 / 80 r.p.m. 60 / 0 r.p.m. 60 / 60 r.p.m. 50 / 50 r.p.m. 60 / 60 r.p.m. 650 / 650 r.p.m. 60 / 60 r.p.m. 50 / 50 r.p.m. S-LOW-SPEED - / 50 r.p.m. - / 50 r.p.m. - / 00 r.p.m. - / 00 r.p.m. DISCRIMINATION MFE-5ROM MFE-5ROM MFE-5ROM MFE-5ROM OUTDOOR UNIT HIGH-SPEED Cool 780 / Heat 780 r.p.m. Cool 850 / Heat 900 r.p.m. Cool 850 / Heat 900 r.p.m. Up Fan 850 / Down Fan 750 r.p.m. DIMENSIONS INDOOR UNIT HxWxD 9-/" x -/" x -/" inch ( 6 x 80 x 80 mm ) -5/8" x -/" x -/" inch ( 96 x 80 x 80 mm ) OUTDOOR UNIT HxWxD -/" x 5-/" x " inch ( 80 x 900 x 0 mm ) 50-7/8" x 5-/" x " inch,90 x 900 x 0 mm WEIGHT INDOOR UNIT GROSS / NET / kg / kg 5/7 kg 55/0 kg OUTDOOR UNIT GROSS / NET 70/6 kg 70/6 kg 70/6 kg / 05 kg

3 TYPE COOLING & HEATING INDOOR UNIT AUU8RCLX AUURCLX AUU6RCLX OUTDOOR UNIT AOU8RLX AOURLX AOU6RLX AUURCLX AOURLX NOISE LEVEL HIGH-SPEED.0 db INDOOR UNIT MED-SPEED 9.0 db OUTDOOR UNIT LOW-SPEED COOL 6.0 db 5.0 db HEAT 5.0 db 5.0 db 8.0 db.0 db 5.0 db 8.0 db.0 db 5.0 db 5.0 db 55.0 db 55.0 db 50.0 db 8.0 db.0 db 55.0 db 56.0 db REFRIGERANT CHARGE (R0A) MAX PIPE LENGTH 50 m MAX PIPE HEIGHT 0 m 0 m 0 m 0 m Pipe Length 9 ft. (5 m) lb oz (,900 g) lb oz (,900 g) lb oz (,00 g) 7 lb 8 oz (,00 g) 66 ft. (0 m) lb 7 oz (,000 g) lb 0 oz (,00 g) 5 lb 5 oz (,00 g) 7 lb 8 oz (,00 g) 98 ft. (0 m) lb oz (,00 g) 5 lb 8 oz (,500 g) 6 lb oz (,800 g) 8 lb 6 oz (,800 g) FULL CHARGE AMOUNT ft. (0 m) 5 lb 5 oz (,00 g) 6 lb 6 oz (,900 g) 7 lb oz (,00 g) 9 lb oz (,00 g) 6 ft. (50 m) 5 lb oz (,600 g) 7 lb 5 oz (,00 g) 7 lb 5 oz (,600 g) 0 lb oz (,600 g) 97 ft. (60 m) lb 0 oz (5,000 g) 0 ft. (70 m) lb oz (5,00 g) ADDITIONAL REFRIGERANT 0. oz / ft. (0 g/ m) 0. oz / ft. (0 g/m) 50 m 50 m 70 m 005..

4 DIMENSIONS INDOOR UNIT Models : AUU8RCLX, AUURCLX Unit : inch (mm) 9-/" (5) 7-7/8" (00) -/6" (0) 9-/" (6) -/8" (60) 7" (90) Drain inside Dia. ø-/" (ø) outside Dia. ø-/" (ø7) -/" (98.5) " (05.5) 9-5/" (8.5) 7" (90) -/" (70) -5/6" (00) -/8" (60) 9-7/" (750mm) -/" (80mm) " (05.5) -/" (98.5) 9-5/" (8.5) -/" (70) 9-7/" (750mm) -/" (80mm) -5/6" (00)

5 INDOOR UNIT Models : AUU6RCLX, AUURCLX Unit : inch (mm) 7" (90mm) 9-7/" (750mm) -/" (80mm) -/6" (0mm) -5/8" (96mm) 7" (90mm) 9-7/" (750mm) -/" (80mm) -7/" (85mm) -/8" (60mm) Drain pipe (I.D.-/" (mm)) (O.D.-/" (7mm)) " (05.5mm) -/" (98.5mm) 9-5/" (8.5mm) -/" (0mm) 5-9/" (50mm) -/8" (60mm) Drain pipe (I.D.-/" (mm)) (O.D.-/" (7mm)) " (05.5mm) -/" (98.5mm) 9-5/" (8.5mm) -/" (0mm) 5-9/" (50mm) 9-7/" (50mm)

6 OUTDOOR UNIT Models: AOU8RLX, AOURLX, AOU6RLX Unit : inch (mm) 5-/" (900) "(77) -/" () " (0) /" () /8" (9) -/" (80) 7/8" () 7-/8" (0) 5-/" (00) 5-5/8" (650) Air Flow -5/8" (70) -7/8" (99) 7-/" (96) 5-/" (7) 6-/" (70)

7 OUTDOOR UNIT Model : AOURLX Unit : inch (mm) 5-/" (900) "(77) -/" () " (0) /" () /8" (9) 7/8" () 50-7/8" (,90) 5-/" (900) 5-/" (00) 5-5/8" (650) Air Flow -5/8" (70) -7/8" (99) 7-/" (96) 5-/" (7) /" (70)

8 REFRIGERANT SYSTEM DIAGRAM Models : AUU8RCLX / AOU8RLX OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe.7mm (/") High Pressure Switch Charging Valve Condenser Muffler -way Valve Evaporator Accumulator Compressor Expansion Valve Refrigerant Pipe 6.5mm (/") Strainer Strainer Charging Valve : COOL : HEAT

9 Models : AUURCLX / AOURLX AUU6RCLX / AOU6RLX OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe 5.88mm (5/8") High Pressure Switch Charging Valve Condenser Muffler -way Valve Evaporator Accumulator Compressor Expansion Valve Refrigerant Pipe 9.5mm (/8") Strainer Strainer Charging Valve Models : AUURCLX / AOURLX OUTDOOR UNIT INDOOR UNIT Pressure Check Valve Refrigerant Pipe 5.88mm (5/8") High Pressure Switch Charging Valve Muffler -way Valve Condenser Accumulator Evaporator Compressor Strainer Expansion Valve Refrigerant Pipe 9.5mm (/8") Strainer Strainer Charging Valve : COOL : HEAT

10 CIRCUIT DIAGRAM Models : AUU8RCLX, AUURCLX TO REMOTE CONTROL UNIT TERMINAL G POWER SUPPLY PCB ASSY L N GREEN (N) Use T.5A-50V Fuse on F0 TO OUTDOOR UNIT GRAY GRAY CN7 CN7 TERMINAL CN5 CN0 CN CN6 CN6 CN CN5 PURPLE 5 5 BLUE 6 6 PIPE TEMPERATURE THERMISTOR ROOM TEMPERATURE THERMISTOR CN8 BROWN BROWN ORANGE ORANGE M YELLOW YELLOW CONTROLLER PCB ASSY YELLOW YELLOW M FAN MOTOR GREEN / YELLOW FM STEP MOTOR FLOAT SWITCH DRAIN PUMP MOTOR FAN MOTOR CAPACITOR Models : AUU6RCLX, AUURCLX TO REMOTE CONTROL UNIT POWER SUPPLY PCB TERMINAL L N GREEN Use T.5A-50V Fuse on F0 CN7 GRAY GRAY CN7 CONTROLLER PCB CN8 CN CN CN0 CN5 BROWN ORANGE YELLOW 5 5 PIPE TEMPERATURE THERMISTOR ROOM TEMPERATURE THERMISTOR FAN MOTOR CAPACITOR 5 5 FLOAT SWITCH BROWN STEP MOTOR ORANGE M YELLOW G (N) TO OUTDOOR UNIT TERMINAL CN6 CN5 DRAIN PUMP MOTOR YELLOW YELLOW M FM FAN MOTOR

11 Model : AOU8RLX, AOURLX COMPRESSOR CHOKE COIL U PIPE TEMPERATURE THERMISTOR DISCHARG TEMPERATURE THERMISTOR BROWN EMI FILTER CONNECTOR T V W ACTIVE FILTER MODULE TERMINAL L L + - BROWN ORANGE 5 YELLOW 6 P N YELLOW BLUE EMI FILTER T BROWN U W05 V W0 W W0 W W W6 W7 W0 W CN BLUE BROWN CN CN CN CN6 CN5 CN07 5 FUSE F T 5A-50V CN7 CN80 CN7 CN W00 CN0 CONTROLLER PCB ASSY FUSE F T.5A-50V YELLOW 5 BLUE 6 BROWN BLUE ORANGE YELLOW 5 6 OUTDOOR TEMPERATURE THERMISTOR COMPRESSOR TEMPERATURE THERMISTOR HEAT SINK TEMPERATURE THERMISTOR WV FM EV HIGH PRESSURE SWITCH SOLENOID COIL FANMOTOR EXPANSION VALVE COIL TM0 BROWN CN W9 W8 POWER SUPPLY PCB ASSY TM0 W W6 W7 W W5 GREEN G EARTH (N) L N G EARTH

12 Model : AOU6RLX CHOKE COIL COMPRESSOR U W TERMINAL PIPE TEMPERATURE THERMISTOR DISCHARGE TEMPERATURE THERMISTOR BROWN CONNECTOR EMI FILTER T V ACTIVE FILTER MODULE POSISTOR L L + - BROWN ORANGE 5 6 YELLOW P N BROWN YELLOW BLUE EMI FILTER T ORANGE ORANGE 5 BLUE BROWN CN CN CN CN6 CN5 U W05 V W0 W W0 CN07 W W W W W6 W7 W0 W FUSE F T 5A-50V CONTROLLER PCB ASSY CN7 CN0 CN80 FUSE F T.5A-50V CN7 CN CN W YELLOW BLUE BROWN BLUE ORANGE YELLOW 5 6 OUTDOOR TEMPERATURE THERMISTOR COMPRESSOR TEMPERATURE THERMISTOR HEAT SINK TEMPERATURE THERMISTOR WV HIGH PRESSURE SWITCH SOLENOID COIL FAN MOTOR FM EXPANSION VALVE COIL EV TM0 GREEN BROWN CN W9 W8 POWER SUPPLY PCB ASSY TM0 W W6 W7 W W EARTH G (N) L N G EARTH 005..

13 Model : AOURLX U PIPE TEMPERATURE THERMISTOR DISCHARGE TEMPERATURE THERMISTOR EMI FILTER CONNECTOR T COMPRESSOR BROWN BLUE BROWN CN CN CN CN6 CN5 U W05 CN7 OUTDOOR TEMPERATURE THERMISTOR COMPRESSOR TEMPERATURE THERMISTOR HEAT SINK TEMPERATURE THERMISTOR HIGH PRESSURE SWITCH CHOKE COIL W TERMINAL RELAY GRAY V BROWN EMI FILTER T TERMINAL DIODE BRIDGE GRAY ACTIVE FILTER MODULE 5 6 L L + - ORANGE + - P N BROWN ORANGE YELLOW VIOLET EMI FILTER T ORANGE POSISTOR YELLOW BLUE EMI FILTER T EMI FILTER T V W0 W W0 5 TM0 TM0 GREEN CN07 W W5 W07 W08 CN CN W00 FUSE F T 5A-50V CONTROLLER PCB ASSY FUSE F T.5A-50V BROWN CN W8 CN80 CN80 W9 CN0 CN7 POWER SUPPLY PCB ASSY W W6 W7 W W YELLOW BLUE YELLOW BLUE BROWN BLUE ORANGE YELLOW WV FM FM EV SOLENOID COIL EMI FILTER T FAN MOTOR FAN MOTOR EXPANSION VALVE COIL EARTH G (N) L N G EARTH 005..

14 INDOOR PCB CIRCUIT DIAGRAM Models : AUU8RCLX AUURCLX CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUU8RCLX : K0AL-050KHSE-C AUURCLX : K0AL-050LHSE-C 005..

15 Models : AUU6RCLX AUURCLX CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUU6RCLX : K0AL-050MHSE-C AUURCLX : K0AL-050NHSE-C 005..

16 OUTDOOR PCB CIRCUIT DIAGRAM Models : AOU8RLX AOURLX INVERTER ASSEMBLY AOU8RLX : EZ-005GHUE AOURLX : EZ-005FHUE POWER SUPPLY PCB ASSY K0BA-0500HUE-P0 CONTROLLER PCB ASSY AOU8RLX : K0AW-050HUE-C AOURLX : K0AW-050HUE-C

17 Model : AOU6RLX INVERTER ASSY EZ-005HHUE AC0V 60Hz POWER SUPPLY PCB K0BA-050HUE-P0 TERMINAL HP-T06- CONTROLLER PCB ASSY K0AW-050HUE-C

18 INVERTER ASSY EZ-005KHUE Model : AOURLX AC0V 60Hz POWER SUPPLY PCB K0BA-050HUE-P0 CONTROLLER PCB ASSY K0AW-0505HUE-C

19 Models : AOU8RLX, AOURLX, AOU6RLX CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AOU8RLX : K0AW-050HUE-C AOURLX : K0AW-050HUE-C AOU6RLX : K0AW-050HUE-C /50V x

20 Model : AOURLX CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AOURLX : K0AW-0505HUE-C /50V x 5

21 Models : AOU8RLX, AOURLX AOU6RLX, AOURLX POWER SUPPLY PCB ASSEMBLY AOU8RLX, RLX : K0BA-0500HUE-P0 AOU6RLX, RLX : K0BA-050HUE-P0 * AOU8RLX, AOURLX : W and W5 AOU6RLX, AOURLX : W and W POWER SOURCE 0V 60Hz * * W or W W or W5 B B VA0 70V <TNR> VA0 70V <TNR> C0. <LE> SA00 RA-0M L RCH70-0PF07 C0 0.0 <YE> C <YE> C06. <LE> TM00 L N00500KD7C C07. <LE> TO INDOOR UNIT W6 W7 B B CT CT-B EARTH W GREEN B 5V D60 DAN7U + AC VOLT OUT W8 W9 B B R60.0K </0W> (%) C60 0/6V <PJ> L RCH70-0PF07 C. <LE> C 0.05 <YE> C 0.05 <YE> VR BK R6.7K </0W> (%) R68 K </0W> C6 0. <F> C65 0. <F> 5V TM0 TM0 CN BB-XASK--A CT OUT

22 ERROR CONTENTS (indoor unit) () Stop the air conditioner operation. () Press the master control button and the fan control button simultaneously for seconds or more to start the test run. () Press the start/stop button to stop the test run. [SELF-DIAGNOSIS] Test run display When the error indication "E:EE" is displayed, follow the following items to perform the self-diagnosis. "E:EE" indicates an error has occurred.. REMOTE CONTROLLER DISPLAY () Stop the air conditioner operation. () Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis. Refer to the following tables for the description of each error code. Unit number (usually 0) Error code Error code A b c d E F Error contents Outdoor signal abnormal Excessive outdoor pressure (permanent stop) Compressor temperature sensor Pressure switch error IPM error CT error Active filter module (AFM) error Compressor does not operate Outdoor unit fan error Communication error (inverter multicontroller) way valve sensor error Expansion valve error Connection indoor unit error SU MO TU WE TH FR SA Ex. Self-diagnosis () Press the set temperature buttons simultaneously for 5 seconds or more to stop the self-diagnosis.. CHECKING DRAINAGE To check the drain, remove the water cover and fill with to of water as shown in figure. The drain pump operates when operating in the cooling mode. Error code A 0c Error contents Communication error (indoor unit remote controller) Communication error (indoor unit outdoor unit) Room temperature sensor open Room temperature sensor short-circuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor shortcircuited Outdoor heat exchanger temperature sensor Power source connection error Float switch operated Outdoor temperature sensor Discharge pipe temperature sensor Model abnormal Indoor fan abnormal Drain pipe Watering pot Water cover

23 ERROR CONTENTS (outdoor unit). Make a TEST RUN in accordance with the installation instruction sheet for the indoor unit.. OUTDOOR UNIT LEDS When a malfunction occurs in the outdoor unit, the LED on the circuit board lights to indicate the error. Refer to the following table for the description of each error according to the LED. LED flash flash flash flash 7 flash 8 flash 9 flash flash flash flash 5 flash 6 flash lighting Error contents Communication error (Indoor unit - Outdoor unit) Discharg pipe temperature sensor Outdoor heat exchanger temperature sensor Outdoor temperature sensor Compressor temperature sensor Heat sink temperature sensor Pressure switch abnormal IPM error Compressor rotor position cannot detect Compressor cannot operate Outdoor fan abnormal (upper fan) Outdoor fan abnormal (lower fan) No error. When the product is operating: Press the PUMP DOWN switch on the outdoor unit. The LED on the outdoor unit circuit board lights, and operation stops. At this point, recovery has not been completed, so do not close the two- and three-way valves. The pump down operation (cooling operation) begins after three minutes. Close the three-way valve (liquid) after operation starts. After - minutes, operation stops. Close the threeway valve (gas) within one minute after operations stops. The LED will go out three minutes after it stops. Disconnect the power supply after confirming that the LED has gone out. *When the pump down operation is repeated, temporarily disconnect the power supply after opening the closed valves (both liquid and gas). Reconnect the power supply after - minutes and perform the pump down operation. *When the start of the operation after pump down operation has been completed, temporarily disconnect the power supply after opening the closed valves (both liquid and gas). Reconnect the power supply after - minutes and be sure to perform a test operation for cooling. -way valve (Liquid) SPECIAL INSTALLATION SETTING PUMP DOWN (Refrigerant collecting operation) Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.. When the product is stopped: -way valve (Gas) PUMP DOWN SW (SW) Press the PUMP DOWN switch on the outdoor unit. (The LED on the outdoor unit circuit board lights.) The pump down operation (cooling operation) begins right away. After oparation starts, close the three-way valve (liquid). After - minutes, operation stops. Close the threeway valve (gas) within one minute after operations stops. The LED will go out three minutes after it stops.disconnect the power supply after confirming that the LED has gone out. DANGER This part (Choke coil) generates high voltages. Never touch this part

24 A DISASSEMBLY ILLUSTRATION Models : AUU8RCLX AUURCLX AUU6RCLX AUURCLX

25 Models : AUU8RCLX AUURCLX

26 Models : AUU6RCLX AUURCLX

27 Models : AUU8RCLX AUURCLX AUU6RCLX AUURCLX

28 Models : AUU8RCLX AUURCLX

29 Model : AUU6RCLX

30 Model : AUURCLX

31 Models : AOU8RLX AOURLX AOU6RLX

32 Models : AOU8RLX AOURLX AOU6RLX

33 Models : AOU8RLX AOURLX AOU6RLX

34 Models : AOU8RLX AOURLX AOU6RLX

35 Model : AOURLX

36 Model : AOURLX

37 Model : AOURLX

38 Model : AOURLX

39 PARTS LIST INDOOR UNIT Ref. No. Description AUU8RCLX Part No. AUURCLX Ord. Q'ty Ref. No. Description AUU8RCLX Part No. AUURCLX Ord. Q'ty Control Box Assy Capacitor (Fan Motor) Decoration Plate Holder (Hook) Filter Holder (Louver Supporter) Drain Hose Separate wall RFM (Grille)-C RFM (Grille)-D RFM (Grille)-E Turbo Fan Assy Washer (Turbo Fan) Bellmouth-B Float Switch Insulation (Grille)-A Evaporator-A Assy Evaporator-B Assy Kit (Drain Pan Sub Assy) Motor, Induction Cabinet-E Thermistor Spring-A Clamp No Binder-C Insulation (Grille)-B Pump Unit Hook Hinge Wire (Grille) Drain Pan Plug Control Box Cover Joint Gear Terminal Base Wind Guide Board Clamp NK-N Control Box Motor Gear Room Temp. Thermistor Pipe Temp. Thermistor Controller PCB Assy (K0AL-050KHSE-C) (K0AL-05LHSE-C) 5- Terminal Cover Panel Base Holder (Panel Frame) Holder (Panel Base) Panel Frame Inner Box Evaporator Holder Assy Cord Bushing Remote Control Unit Pipe Cover Assy A Wire Assy Wire Clamp Metal Wire Cover RFM (Eva. )-A RFM (Eva. )-B Motor Holder Joint-A Joint Shaft Louver Assy Intake Grille Holder Distributor Assy Hook (Grille)-A Hook (Grille)-B Locking Spacer Spacer RFM (Drain Pan) Pump Cover-A Pump Cover-B Panel (Top) Assy Cabinet-A Assy Cabinet-B Assy Drain Pump Holder Cabinet-D Cabinet-C Terminal-P Terminal-P Cover (Wire)-A Cover (Wire)-B Cushion (Pump) Drain Port M0 Nut-A (Large) M0 Nut-B (Small) RFM (Grille)-A RFM (Grille)-B Louver Supporter Spring (Grille) Power Supply PCB Assy Motor, Step Coupling Pipe Assy When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.

40 INDOOR UNIT Ref. No. Description AUU6RCLX Parts No. AUURCLX Ord. Q'ty Ref. No. Description AUU6RCLX Parts No. AUURCLX Ord. Q'ty Control Box Assy Capacitor (Fan Motor) 6 Decoration Plate 7 Grille Hook Holder 9 Filter Rubber Support Holder 7 Drain Hose 8 Separate Wall Grille Reinforcement-T (C) Grille Reinforcement-T (D) Grille Reinforcement-T (E) Turbo Fan Assy Spacial Washer Bellmouth-B Float Switch Insulation (Grille)-A Evaporator-A Assy 6- Evaporator-B Assy 60 Kit (Drain Pan Assy) 6 Fan Motor Assy-IN 68 Cabinet-E 8- Thermistor Spring-A 87 Clamp No Clamp SKB Insulation (Grille)-B Pump Unit Hook Grille Hinge Wire Drain Pan Plug Control Box Cover Joint Gear Terminal Plate Wind Guide Board Clamp NK-N Control Box Motor Gear Room Temperature Thermistor Pipe Temperature Thermistor Controller PCB Assy (K0AL-050MHSE-C) (K0AL-050NHSE-C) 5- Terminal Cover Panel Base Panel Frame Holder Panel Base Holder Panel Frame Holder Inner Box Evaporator Holder Assy Cord Bushing Remote Control Unit Pipe Cover Assy A Wire Assy Reinforcement (Eva. )-A 7- Reinforcement (Eva. )-B 0- Wire Clamp Metal Wire Cover 8 Motor Holder Joint-A Joint Shaft Louver Assy Intake Grille Holder Distributor Assy Grille Hook-A Grille Hook-B Locking Spacer Spacer Reinforcement (Drain Pan) Pump Cover-A Pump Cover-B Top Cover Plate Cabinet-A Cabinet-B Pump Hook Bracket Cabinet-D Cabinet-C Terminal-P Terminal-P Wire Cover-A Wire Cover-B Cushion Rubber (Pump) Drain Port 68 Spacial Nut-A (Large) 69 Spacial Nut-B (Small) 7- Grille Reinforcement-T (A) Grille Reinforcement-T (B) Louver Supporter Grille Spring Power Supply PCB Assy Motor, Step Coupling Pipe Assy Rubber (Discharge Pipe) When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.

41 OUTDOOR UNIT Ref. Description No. AOU8RLX Part Number AOURLX AOU6RLX Ord. Q'ty Top Panel Sub Assy Front Panel Fan Guard Grip Side Service Panel Sub Assy Right Panel Emblem Rear Propeller Fan Assy Motor, Induction Condenser-A Assy Strainer Assy Separate Wall Assy Cap Foot Base Assy Way Valve Assy (/8) Way Valve Assy (/) Way Valve Assy (5/8) Way Valve Assy (/) Check Joint Assy Compressor Assy Way Valve Solenoid Pressure Switch Inlet Pipe Cond A Assy Inlet Pipe Cond B Assy Outlet Pipe Cond A Assy Expansion Valve Assy Coil (Expansion Valve) Distributor Discharge Pipe A Assy Terminal P Terminal 5P ACTPM Holder Thermo Inverter PCB Assy Power PCB Assy Motor Bracket Sub Assy Choke Coil Inverter Box A Inverter Box B Inverter Box C Inverter Box Duct 5 Inverter Box Cover Fuse.5A-50V Thermistor (Outdoor Temp.) Heat Exchanger Thermistor Thermistor (Discharge) Compressor Thermistor Thermistor Heatsink Thermistor Transformer Varistor Arrester Relay Relay Switch Push Switch Slide Drain Pipe Assy Drain Cap When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.

42 OUTDOOR UNIT Ref. No. Description Top Panel Sub Assy Front Panel X Fan Guard Grip Side 5 Service Panel Sub Assy 6 Right Panel Sub Assy 7 Valve Cover 9 Propeller Fan Assy 0 Motor DC Brushless Condenser A Assy Condenser B Assy Sepa Wall Cap Foot 5 Base Assy 7 -Way Valve Assy (/8) 8 -Way Valve Assy (8/8) 9 Compressor Assy 0 Accumulator Assy Solenoid Pressure Switch -Way Valve Check Valve Assy 5 Coil (Expansion Valve) 6 Strainer Assy 7 Inverter Box A 8 Inverter Box B 9 Inverter Box C 0 Inverter Box Duct Inverter Box Cover Heat Sink A Act Module Relay 5 Terminal 6 Posistor 7 Inverter PCB Assy 8 Power PCB Assy 9 Clamp (Cord) 0 Terminal --- Expansion Valve --- Thermistor (Dischage) --- Thermistor (Heat Exchange) --- Thermistor (Out Temp) --- Emblem-Rear --- Holder Thermo --- Fuse.5A-50V --- Heatsink Thermistor --- Varistor --- Arrester --- Relay --- Switch Slide --- Drain Pipe Assy Parts No. AOURLX Ord. Q'ty When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column.

43 STANDARD ACCESSORIES INDOOR UNIT ACCESSORIES Name and Shape Coupler heat insulation Q ty Application For indoor side pipe joint Tapping Screw (flush heads) For installing the remote controller Special nut A (large flange) For installing indoor unit Special nut B (small flange) For installing indoor unit Template For ceiling hole cutting Binder (small) For fixing the remote controller cord Blower cover insulation For discharged air Hook wire For installing intake grille Remote controller Remote controller cord For connecting the remote controller

44 WARNING For the air conditioner to operate satisfactorily. install it as outlined in this installation instruction sheet. Connect the indoor unit and outdoor unit with the room air conditioner piping and cords available standards parts. This installation instruction sheet describes the correct connections using the installation set available from our standard parts Installation work must be performed in accordance with national wiring standards by authorized personnel only. Also, do not use an extension cord. Do not turn on the power until all installation work is complete. Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation. There is not extra refrigerant in the outdoor unit for air purging. Use a vacuum pump for R0A exclusively. Using the same vacuum pump for different refrigerants may damage the vacuum pump or the unit. Use a clean gauge manifold and charging hose for R0A exclusively. If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant comes in contact with a flame, it produces a toxic gas. Be careful not to scratch the air conditioner when handling it. After installation, explain correct operation to the customer, using the operating manual. Let the customer keep this installation instruction sheet because it is used when the air conditioner is serviced or moved. STANDARD PARTS The following installation parts are furnished. Use them as required. Drain pipe Drain cap Name and Shape Q'ty Application 5 For outdoor unit drain piping work (May not be supplied, depending on the model.) CONNECTION PIPE REQUIREMENT CAUTION The maximum lengths of this product are shown in the following table. If the units are further apart than this, correct operation can not be guaranteed. Model Type Diameter Liquid Gas 8,000 BTU/h class 6.5 mm (/ in.).7 mm (/ in.),000 BTU/h class 9.5 mm (/8 in.) 5.88 mm (5/8 in.) 6,000 BTU/h class,000 BTU/h class 9.5 mm (/8 in.) 5.88 mm (5/8 in.) 9.5 mm (/8 in.) 5.88 mm (5/8 in.) Pipe length MAX. MIN. 50 m (65 ft) 5 m (6 ft) 50 m (65 ft) 5 m (6 ft) 50 m (65 ft) 5 m (6 ft) 70 m (0 ft) 5 m (6 ft) Maximum height (between indoor and outdoor) 0 m (66 ft) 0 m (66 ft) 0 m (98 ft) 0 m (98 ft) Use pipe with water-resistant heat insulation. CAUTION Install heat insulation around both the gas and liquid pipes. Failure to do so may cause water leaks. Use heat insulation with heat resistance above 8 F. (Reverse cycle model only) In addition, if the humidity level at the installation location of the refrigerant piping is expected to exceed 70%, install heat insulation around the refrigerant piping. If the expected humidity level is 70-80%, use heat insulation that is 5 mm (9/") or thicker and if the expected humidity exceeds 80%, use heat insulation that is 0 mm (/6") or thicker. If heat insulation is used that is not as thick as specified, condensation may form on the surface of the insulation. In addition, use heat insulation with heat conductivity of 0.05 W/(maK) or less (at 68 F)

45 05G977

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC ARG30ALC ARG30RLC ARY30ALC ARY30RLC ART30ALC ART30RLC AOG25ANBL AOG25RNBL

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8, Order No. MAC0605029C2 Air Conditioner CS-F18DTE5 CU-B34DBE5 CS-F18DTE5 CU-B34DBE8 CS-F24DTE5 CU-B43DBE8 CS-F28DTE5 CU-B50DBE8 Please file and use this manual together with the service manual for Model

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

Кондиционеры Mitsubishi Heavy

Кондиционеры Mitsubishi Heavy Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Rev 8/08 # This parts

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50HZ units Mile High Equipment 11100 East 45th Ave Denver, Colorado 80239 Print Date 03/03 * This parts list contains

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*R07LGC AO*R09LGC AO*R12LGC AO*R14LGC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*A07LGC AS*A09LGC AS*A2LGC AS*A4LGC AO*R07LGC AO*R09LGC AO*R2LGC AO*R4LGC R40A CONTENTS.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

6868 Ardmore Street Houston, Texas Toll Free Phone Fax

6868 Ardmore Street Houston, Texas Toll Free Phone Fax P-09 P-09 P-09A COMPONENT PART NO. COMPONENT PART NO. BASE PAN 67904000 AIR OUTTAKE 67809008 OUTDOOR CENTRIFUGAL FAN 67809032 TURNING WHEEL (CASTER) 67904001 (4) ERECT LOUVER ASSY 67809006 (5) OUTDOOR

More information

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering

More information

KE-436C Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function

KE-436C Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function KE436C Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function Specifications Stitch formation Maximum sewing speed Maximum pattern size (X x Y) Feed mechanism Stitch length No.

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K

More information

AIR CONDITIONER. Model : 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

AIR CONDITIONER. Model : 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5. SYSTEM AIR CONDITIONER Model : INDOOR UNIT AC012MNADCH/AA AC018MNADCH/AA AC024MNADCH/AA AC030MNTDCH/AA AC036MNTDCH/AA OUTDOOR UNIT AC012KXADCH/AA AC018JXADCH/AA AC024JXADCH/AA AC030JXADCH/AA AC036JXADCH/AA

More information

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1 Order No: MAC0512115C1 CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU Air Conditioner CONTENTS Page Page 1 Safety Precautions 3 2 Specification 5 2.1. CS-E18EKU CU-E18EKU 5 2.2. CS-E21EKU CU-E21EKU 7 3 Location

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

Commercial Refrigerator & Freezer Service Manual

Commercial Refrigerator & Freezer Service Manual Commercial Refrigerator & Freezer Service Manual Sandwich Salad Unit Under counter Refrigerator & Freezer Model No.: TUR-28SD TUR-48SD TST-28SD TST-48SD TUF-28SD TUF-48SD TABLE OF CONTENTS. FEATURE CHART

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Service Manual Indoor AW09ESVHA AWESVHA AW8ESVHA AWESVHA Outdoor U09ESVHA UESVHA U8ESVHA UESVHA Design may vary by model number. Please read this manual before using the

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL R07C Outdoor unit [model names] No.OC6 REVISED EDITION-B PUH-PVGAA PUH-P.6VGAA PUH-P.6YGAA PUH-PVGAA PUH-PYGAA

More information

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

Item RED=NLA-NR=No Longer Available-No Replacement Code Part Description Part Number GRP

Item RED=NLA-NR=No Longer Available-No Replacement Code Part Description Part Number GRP 5.0 CUBERS C136-C186 "B" SERIES AIR, WATER AND REMOTE Code Part Description Part Number GRP 136 186 AIR COOLED 5 Air Condenser 9141064-01 AC X 10 Fan Blade 10" 9131053-01 AC X 15 Fan Motor 35 watt 9161124-03

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No. 852 360 86

More information

SERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32

SERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32 OUTDOOR UNIT SERVICE MANUAL HFC utilized R32. Models MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 Indoor unit service manual MSZ-LN VGW/V/B/R

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE -(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3

More information

SERVICE MANUAL K LIGHT COMMERCIAL

SERVICE MANUAL K LIGHT COMMERCIAL SERVICE MANUAL 36 48 60K LIGHT COMMERCIAL Cassette indoor unit Under-ceiling indoor unit Ducted indoor unit 42QTD036DS* 42QTD048DS* 42QTD060DS* 42QZL036DS* 42QZL048DS* 42QZL060DS* 42QSM036DS* 42QSM048DS*

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS0971 + C0971 + CL0971 KS1271 + C1271 + CL1271 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS0971 KS1271 Product

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS TECHNICAL GUIDE PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS MODELS: DCPM/DHPM Due to continuous product improvement, specifications are

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Inverter-controlled multi system Models E MXZ-A8WV - E MXZ-A6WV - MXZ-AWV - E HFC utilized R40A No. OB9 Indication of model name MXZ-A8WV - E CONTENTS.

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

SERVICE MANUAL. Room Air Conditioner

SERVICE MANUAL. Room Air Conditioner SERVICE MANUAL Room Air Conditioner MODELS AF-S60FX AF-R80FX AF-S80FX AF-S85FX AF-R100FX AF-S100FX AF-R120FX AF-S120FX AF-S125FX In the interests of user-safety (Required by safety regulations in some

More information

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007 Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.

More information

CU0415, CU0715 and CU0920 Service Parts

CU0415, CU0715 and CU0920 Service Parts CU0, CU0 and CU00 Service Parts This is the illustrated parts list for the CU0, CU0 and CU00. The CUR0, CUR0 and CUR00 are - (0-0/0/) versions of the matching models. There are voltages, /0/, 0-0/0/ and

More information

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...

More information

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com Parts List Low-Profile Modular Crescent Cuber Models KML-325MAJ KML-325MWJ hoshizakiamerica.com Number: 71377 Issued: 4-7-2017 Revised: 9-8-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

(2) 325 tpd York Chlorine Liquefier Systems

(2) 325 tpd York Chlorine Liquefier Systems (2) 325 tpd York Chlorine Liquefier Systems The liquefier is a split bundle and serves as both the primary liquefier and the secondary liquefier. The total for each York system is 325 tons liquid Cl2,

More information

Lennox 8 Series Single Zone - R-410A

Lennox 8 Series Single Zone - R-410A PRODUCT SPECIFICATIONS MINI-SPLIT SYSTEMS MS8C/MS8H Lennox 8 Series Single Zone - R-410A Bulletin No. 210632 September 2016 Supersedes January 2016 MS8-CI Air Conditioner Indoor Unit MS8-HI Heat Pump Indoor

More information

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

INSTALLATION MANUAL For authorized service personnel only.

INSTALLATION MANUAL For authorized service personnel only. AIR CONDITIONER INDOOR UNIT Compact Cassette Type INSTALLATION MANUAL For authorized service personnel only. Contents. SAFETY PRES... 2.. IMPORTANT! Please read before starting... 2.2. SPECIAL PRES...

More information

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION HEAT PUMP OUTDOOR UNITS lps13dc DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 210637 June 2014 Supersedes June 2012 1.5 to 5 Tons MODEL NUMBER IDENTIFICATION L P S 13 DC - 036-230 - 2 Lennox Minor

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COMBINATION HEATING AND COOLING ROOFTOP UNITS RKKB SERIES 7.5, 8.5, 10, 12.5 & 15 TON [26.4, 29.9, 35.2 44 & 52.8 kw] RKMB SERIES 7.5, 8.5, 10 & 12.5 TON [26.4, 29.9, 35.2

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

1956 FORD F-100 TRUCK

1956 FORD F-100 TRUCK an ISO 9001:2008 Registered Company INSTALLATION INSTRUCTIONS FOR 1956 FORD F-100 TRUCK HEAT/COOL/DEFROST 75456-LFZ-A 18865 GOLL ST. - SAN ANTONIO, TX. - 78266 - ph.210-654-7171 - fax 210-654-3113 905456-LFZ-A

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT DocID: 00G00019E 2008 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts. CMA Dishmachines 1700 Knott Avenue Garden Grove, CA 981 Toll Free: 1- (800) 8-617 Fax: 1- (71) 89-11 Service Replacement Parts Undercounter High Temperature Dishwasher Model: UC6e M Machine Serial No.

More information

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions PHOENIX 200 MAX LOW GRAIN REFRIGERANT HIGH CAPACITY DEHUMIDIFIER Table of Contents Therma-Stor Products Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Phoenix 200 Max Operation

More information

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE Order No. PHAAM1103074C8 Indoor Unit CS-MRE7MKE CS-MRE9MKE CS-MRE12MKE Air Conditioner Outdoor Unit CU-2RE15MBE CU-2RE18MBE TABLE OF CONTENTS PAGE 1 Safety Precautions-----------------------------------------------

More information

SERVICE MANUAL OFFICE PRO 60. Unit Serial Number Range: 0407XXXX600 to Present (From April 2007 to Present)

SERVICE MANUAL OFFICE PRO 60. Unit Serial Number Range: 0407XXXX600 to Present (From April 2007 to Present) SERVICE MANUAL OFFICE PRO 60 Unit Serial Number Range: 0407XXXX600 to Present (From April 2007 to Present) SERIAL NUMBER LOCATION AND IDENTIFICATION Nameplate Label COOLING AMPS. WITH PUMP COMPR. OUTPUT

More information

(EE1500, EE2000, EE2500, EE3000)

(EE1500, EE2000, EE2500, EE3000) EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor

More information

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel)

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel) CABINET PARTS 42" BUILT IN REFRIGERATOR 10 11 Litho In U.S.A. (jdc)(psw) 1 Part No. Rev. A 1 Literature Parts W10161714 Use & Care Guide W10164072 Energy Guide W10159832 Service & Wiring Sheet 2306424

More information

1 L Rotary Vacuum Evaporator Instruction Manual

1 L Rotary Vacuum Evaporator Instruction Manual 1 L Rotary Vacuum Evaporator Instruction Manual Important This manual is designed for safe and optimal performance of this unit Please read manual carefully before operating this unit Keep this manual

More information

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) Distributed By: Commercial Refrigeration Service, Inc. WWW.866IceMakers.COM 866-IceMakers 623-869-8881

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model

More information

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models

More information

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models

More information

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat Electric (Modular) Heat Option 4.75 Kw, 7.5 kw, 9.5 kw, 14.25

More information

CONTROL BOARD PARTS For Model: KHHC2090SSS2 (Stainless Steel)

CONTROL BOARD PARTS For Model: KHHC2090SSS2 (Stainless Steel) CONTROL BOARD PARTS MICROWAVE HOOD COMBINATION 1 Literature Parts W10170438 Use & Care Guide W10132018 Tech Sheet W10131853 Quick Reference 2 8206039 Support, Cavity 3 8206040 Plate, Protection 4 Side

More information

KSSS42QDW05, KSSS42QDX05

KSSS42QDW05, KSSS42QDX05 CABINET PARTS 42" BUILT IN REFRIGERATOR 4 97 Litho In U.S.A. (mek) 1 Part No. CABINET PARTS 1 Cabinet (Not A Serviceable Part) 3 2005004 Grommet, Tube Crossover 4 1112023 Roller, Front & Rear (4) 5 Support,

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT. TFII-11 Beacon/Morris TWIN-FLOIII HEATER INSTALLATION INSTRUCTIONS TYPES K, W, & F ATTENTION: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE THE BEACON MORRIS TWIN-FLO

More information