1 Ron Blank and Associates, Inc Please note: you will need to complete the conclusion quiz online at ronblank.com to receive credit SUSTAINABLE BUILDING TECHNOLOGY REHAU s sustainable building technology provides solutions for heating, cooling, snow and ice melting, plumbing, water supply, fire protection, fresh air supply, and the building envelope Lance MacNevin REHAU Inc Edwards Ferry Rd. Leesburg, VA Lance.MacNevin@rehau.com
2 RADIANT HEATING DESIGN AND CONTROLS AN AIA CONTINUING EDUCATION PROGRAM Credit for this course is 1 AIA HSW CE Hour Course reh23c
3 AN AMERICAN INSTITUTE OF ARCHITECTS (AIA) CONTINUING EDUCATION PROGRAM Approved Promotional Statement: Ron Blank & Associates, Inc. is a registered provider with The American Institute of Architects Continuing Education System. Credit earned upon completion of this program will be reported to CES Records for AIA members. Certificates of Completion are available for all course participants upon completion of the course conclusion quiz with +80%. Please view the following slide for more information on Certificates of Completion through RBA This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA or Ron Blank & Associates, Inc. of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product.
4 AN AMERICAN INSTITUTE OF ARCHITECTS (AIA) CONTINUING EDUCATION PROGRAM Course Format: This is a structured, web-based, self study course with a final exam. Course Credit: 1 AIA Health Safety & Welfare (HSW) CE Hour Completion Certificate: A confirmation is sent to you by and you can print one upon successful completion of a course or from your RonBlank.com transcript. If you have any difficulties printing or receiving your Certificate please send requests to certificate@ronblank.com Design professionals, please remember to print or save your certificate of completion after successfully completing a course conclusion quiz. confirmations will be sent to the address you have provided in your RonBlank.com account. Please note: you will need to complete the conclusion quiz online at ronblank.com to receive credit
5 COURSE DESCRIPTION Thermal comfort through radiant floor heating will be the focus of this course. We will review applications and calculations of the design process for hydronic heating. Controls and zoning for an integrated system will be covered as well.
6 LEARNING OBJECTIVES UPON COMPLETION OF THIS COURSE THE DESIGN PROFESSIONAL WILL BE ABLE TO: Describe the advantages of using radiant floor heating (RFH) technology List several application options for RFH including residential, commercial, civic, industrial, and institutional applications Follow the design process for radiant heating systems to determine heat loss, floor temperatures, piping layouts, and fluid temperatures Explain the basic control systems incorporated in radiant heating systems
7 RADIANT FLOOR HEATING BENEFITS Thermal Comfort Control of temperatures Flexibility in applications and with heat sources Efficiency
8 THERMAL COMFORT RADIANT FLOOR HEATING ADDRESSES ALL THESE THERMAL COMFORT ISSUES: Inconsistent temperature from minute-to-minute (cycling) Inconsistent temperature from one room to another Inconsistent temperature within a room Drafts or wind blowing when the heat turns on Cold hard surface flooring need slippers! Restricted placement of furniture due to heat emitters Noisy fans or ticking baseboard Ugly air vents and return air grates Dusty air and heat emitters Dry air in wintertime
9 THERMAL COMFORT: A WARM FLOOR RADIANT FLOOR HEATING (RFH) IS: MAKES A WARM HOME Quiet, no fans, no noise Steady, with even temperatures throughout a room Invisible, with no holes in floor, no moving curtains Warm, with heat delivered through our feet
10 THERMAL COMFORT Radiant floor heating provides a more correct temperature profile in the space to deliver comfortable temperature distribution in the space 8 ft 8 ft 6 ft 6 ft 6 ft 6 in 6 in 6 in F F F Optimal Temperature Distribution Forced Air or other Convective Heating Radiant Floor Heating
11 THERMAL COMFORT When your feet are warm, your lower body is warm With RFH there is some warm air floating in lower portion of the room Still air means less heat loss from the human body to the air flow Eliminates that drafty feeling caused by forced air movement There is less hot air at the ceiling, less stratification Cooler air at head level is fresher, has more oxygen, is not as dry With RFH, the warmest air is at floor level 8 ft 6 ft 6 in F
12 THERMAL COMFORT Higher Mean Radiant Temperature (MRT) improves comfort in a space Surfaces are warmer than with forced air Bodies radiate less heat to walls and ceilings, therefore indoor air can be cooler and fresher Indoor air does not have to be so hot for comfort Use 68 F vs. 72 F indoor design temperature with radiant floors for most residential applications This delivers improved comfort, increased efficiency Pink Area is the approximate comfort zone
13 THERMAL COMFORT Cooler air has higher Relative Humidity (RH%) in winter as compared with forced hot air. May be less dry skin, fewer dry throats No ductwork is necessary Influence of dust/pollen/allergens may be minimized Hard surface flooring is comfortable and desirable Easier to eliminate carpet and rugs from indoor spaces
14 ROOM CONTROL: DELIVERING COMFORT AND EFFICIENCY In residential applications radiant layouts typically cover 250 ft 2 per circuit of pipe: The flow of water for each circuit is controlled by circuit valves built-in to the manifold That makes room-by-room zoning is easy Room-by-room temperature control optimizes comfort and efficiency Occupants may desire some rooms to be warmer than others Heat loads change with occupancy Typical radiant thermostat and distribution manifold
15 FLEXIBILITY: RADIANT HEATING GIVES CHOICES 1. FLEXIBILITY WITH APPLICATIONS: Use in floors, walls or ceilings Heat the entire building with RFH, or mix it with other hydronic emitters Radiant is zoneable 2. FLEXIBILITY WITH HEAT SOURCES: Almost any source of warm water can power a radiant system
16 PART 1: FLEXIBILITY WITH APPLICATIONS HEAT FLOORS, WALLS OR CEILING HEAT THE ENTIRE BUILDING OR PARTS OF IT: Radiant heating can be installed in almost any building panel Radiant heating may be used as the primary heating system, capable of 34 BTU/hr(ft 2 ) or more Radiant heating may also be used just for floor warming In tiled or hardwood areas, controlled with floor sensors in the floor
17 PART 2: FLEXIBILITY WITH HEAT SOURCES EXAMPLES OF SUITABLE HEAT SOURCES: Condensing boiler ( Mod/Con, for low temperature applications, high efficiency) Ground source heat pump (usually a perfect match of water temperatures) Electric boiler (easy to control and install) Non-condensing boiler (for mixed high temperature/low temperature applications) Solar collectors (with storage tanks and water temperature mixing control device) The first three are well-suited for radiant applications since low water temperatures can be easily controlled
18 EFFICIENCY: RADIANT HEATING CAN SAVE ENERGY 1. Lower average air temperature reduces heat loss: Lower indoor air temperature = less heat loss (68 F for RFH vs. 72 F for FA) 2. More efficient use of boiler or heat source: Condensing boilers operate in full condensing mode only with water return temperature less than 130 F, easily achieved with radiant floor heating Ground source heat pumps operate more efficiently when the temperature required for heat distribution is not much higher than the fluid temperature coming from the ground 3. It s more economical to move heat using water vs. air Hydronic circulators draw less power than furnace blower fan, potentially saving hundreds of dollars per year on heat distribution costs
19 EFFICIENCY: RADIANT HEATING CAN SAVE ENERGY SAVES COSTS AND REDUCES GREENHOUSE GAS EMISSIONS DUE TO THREE KEY REASONS: 1. Lower average air temperature reduces heat loss 2. More efficient use of boiler or heat source 3. It s more economical to move heat using water vs. air In addition: Not pressurizing rooms (no fans) reduces infiltration heat loss (reduced ACH) Zoning capability allows temperature reduction of rooms when not needed Total savings can be up to 30% or more!
20 RADIANT HEATING IS GREEN Thanks to high efficiency, comfortable environments, better air quality, compatibility with renewable energy sources, and use of sustainable products Leadership in Energy and Environmental Design (LEED) rating system recognizes the benefits of radiant heating.
21 RESIDENTIAL APPLICATIONS Basements Slab-on-grade pours Suspended floor overpour Garages Apartments Residential bathroom with overpour
22 COMMERCIAL/ INSTITUTIONAL APPLICATIONS SOME EXAMPLES: Hotels Offices Restaurants Warehouses Museums Day Care Facilities Retirement Homes Schools/Colleges Hospitals Prisons Milwaukee Museum of Art
23 INSTITUTIONAL APPLICATIONS SOME EXAMPLES: Day Care Facilities Retirement Homes Schools/Colleges Hospitals Prisons 11,000 square foot retirement home in Elliot Lake, ON. Each suite has its own thermostat and room control
24 INDUSTRIAL APPLICATIONS SOME EXAMPLES: Warehouses Garages Factories Hangars RFH in warehouses and factories eliminates overhead unit heaters and infrared tubes which could be damaged by forklifts
25 CIVIC APPLICATIONS SOME EXAMPLES: Fire Stations Bus Stations RFH in fire stations eliminates overhead unit heaters and infrared tubes and creates warm, dry floors for safety
26 SUMMARY EXPLAINING THE MAIN BENEFITS: Comfort Control Flexibility Efficiency Typical applications Radiant floor heating has advantages in all these applications
27 RADIANT HEATING DESIGN PROCESS A standard process using calculated values for accurate heating system design Sizing hydronic equipment always starts with the heat loss These equations apply to new construction, renovations and replacement work
28 THERMAL COMFORT ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy says: Thermal comfort is that condition of mind which expresses satisfaction with the thermal environment. Boundaries for thermal comfort according to Standard 55: -Operative temperature: - Summer period: F - Winter period: F -Range of the floor temperature: F -A good radiant design will stay within these limits
29 RADIANT HEATING DESIGN PROCESS Step 1 1a: Calculate Heat Loss of space (gives Heat Source size) 1b: Radiant Panel Heating Requirement (BTU per hour per ft²) 1c: Required Floor Temperature (how warm does the floor need to be?) Step 2: Radiant Panel Design: Determine PEX pipe size, pipe spacing, circuit lengths, and water temperature (designers will have several options) Step 3: Determine Flow Rates for circuits and the entire system Step 4: Determine Head Loss requirements Step 5: Choose Circulator (pump) to meet Flow Rate and Head Loss requirements
30 STEP 1a: HEAT LOSS OF SPACE BTU (BRITISH THERMAL UNIT) DEFINITION: The amount of (heat) energy required to raise one pound of water one degree Fahrenheit Common conversions: 1 kilowatt (kw) = 3,413 BTU/hr 100 W = 341 BTU/hr Ton of energy = 12,000 BTU/hr Historically, a Ton is the amount of cooling achieved by melting 2,000 pounds (1 ton) of ice in one day
31 HEAT LOSS OF THE SPACE Calculate both conductive and air infiltration heat loss according to relevant methods, based on the selected outside design temperature: ACCA Manual J ASHRAE Design the heating system to heat the building at Outside Design Temperature Outside Design Temperature (ODT) is the coldest outside temperature expected for a location for a normal heating season It is not the coldest temperature on record, but rather the lowest one recorded for a particular locale over a 3- to 5-year period - ODT s are published in ASHRAE Fundamentals, Chapter 14
32 CONDUCTIVE HEAT LOSS FORMULA: Conductive Heat Loss = Area (ft 2 ) x T #1 ( F) R-Value of material - The designer needs to calculate the convective heat loss through every exterior panel and every panel with a temperature difference - Example: Garage at 60 F, house at 68 F - There will be heat loss from the house to the garage (and heat gain to the garage)
33 CONDUCTIVE HEAT LOSS NOTE: - Heat loss from the floor through the ground is known as reverse loss - Reverse loss through heated slab edges (slab-on-grade) can be calculated when soil conditions are known, using special equations (not shown here) - Reverse loss through heated floors can be calculated when soil conditions are known, using special equations (not shown here)
34 AIR INFILTRATION HEAT LOSS BASED ON NUMBER OF AIR CHANGES PER HOUR : ACH = fraction of air volume changed in 1 hour Designer must predict or estimate this EXAMPLE: Volume = 1,000 ft 3, 300 ft 3 /hr air changed per hour = 0.3 ACH ACH is typical range for residential Some commercial buildings have multiple air changes per hour ( 1) ACH will be determined by construction quality, mechanical ventilation, code requirements for usage, etc.
35 AIR INFILTRATION HEAT LOSS FORMULA: Convective heat loss = BTU x Volume ft 3 x # ACH x T #1 ( F) ft 3 ( F) BTU is a constant value for air ft 3 ( F) how many ft 3 /hr of air changed each hour STEP 1a: Total heat loss Conduction loss + Air Infiltration loss = Total Heat design conditions We can use this value to size the heat source and the heat delivery system
36 STEP 1b: RADIANT PANEL HEATING REQUIREMENT FORMULA: Radiant Heating Requirement = Total Heat Loss Available ft 2 Note: Not all square footage is available for heating No pipe under walls, refrigerator, kitchen island, bookcase Available ft 2 is less than Total ft 2 (usually 90% - 95% of Total area) EXAMPLE: Heat loss is 50,000 BTU/hr for a building with 2,800 ft 2 total, and 2,500 ft 2 of available floor area 50,000 BTU/hr = 20 BTU/hr(ft 2 ) radiant panel heating requirement 2,500 ft 2
37 STEP 1c: REQUIRED FLOOR TEMPERATURE FORMULA: Floor Surface Temperature = Required Output + Indoor Air Temperature 2.0 EXAMPLE: 20 BTU/hr(ft 2 ) + 68ºF Air = 78ºF Floor Surface Temperature represents the combined Radiant/Convective Heat Transfer Coefficient (HTC) and is valid for typical residential indoor air temperatures
38 REQUIRED FLOOR TEMPERATURE APPROXIMATE HTC VALUES FOR HEATED PANELS: Radiant Floors: 2.0 BTU/hr 2 (35-40% heat is transferred via natural convection) 2.0 represents the combined Radiant/Convective Heat Transfer Coefficient (HTC) Radiant Walls: 1.8 BTU/hr 2 (less natural convection than floors) Radiant Ceiling: 1.6 BTU/hr 2 (very little natural convection) These values apply to standard room temperatures in range of F For colder rooms (like a 55 F warehouse) the HTC will be even higher thanks to greater natural convection For hotter rooms (like a 80 F greenhouse) the HTC may be lower
39 REQUIRED FLOOR TEMPERATURE FLOOR AREA TYPES AND TEMPERATURE LIMITS Floor Area Type Temperature Limit Heat Output (Max.) Perimeter 95ºF (35 C) 54 BTU/hr(ft 2 ) Occupied 85ºF (29 C) 34 BTU/hr(ft 2 ) Bathroom 91ºF (33 C) 46 BTU/hr(ft 2 ) Distribution 95ºF (35 C) 54 BTU/hr(ft 2 ) These temperatures can be considered as design upper limits These limits should not be exceeded without an engineer s approval This table is used to illustrate maximum radiant floor heat output for various floor types
40 REQUIRED FLOOR TEMPERATURE FLOOR AREA TYPES Perimeter 3-foot area near outside walls Occupied Living area inside perimeter area Distribution Hallways No Radiant Heating Under walls, kitchen islands, pantries, refrigerators and freezers, permanent cabinets, bookcases, etc.
41 STEP 2: RADIANT PANEL DESIGN STEPS First, determine panel construction type How will the floor be built? Thick or thin slab? Dry panel? Joist space? Next, research the floor coverings Bare concrete? Carpet? Tile? What R-values? Then the designer: Selects the pipe size 5 choices (3/8 to 1 ) Selects the pipe spacing Tighter spacing helps to avoid floor striping, requires low water temperature, ensures better response time, may even protect flooring against hot spots Calculates the water (fluid) temperature Less pipe density may require higher water temperature, may cause striping This step is done using software
42 RADIANT PANEL DESIGN STEPS First, determine panel construction type How will the floor be built? Thick or thin slab? Dry panel? Joist space?
43 RADIANT PANEL DESIGN STEPS SPECIAL CONSIDERATIONS FOR SUSPENDED SLABS 12 OC Side view of 6 thick slab with 3/4 PEX pipes 6 thick concrete slab 6 thick 3/4 PEX pipe 12 width AREA CALCULATION EXAMPLE: 6-Inch thick slab has 72 in 2 of concrete per foot length (6 x 12 = 72 in 2 ) Cross-sectional area of 3/4 PEX pipe = in 2 Area of 3/4 PEX pipe installed every 12 inch = in 2 pipe per 72 in 2 concrete Percentage of concrete displaced by PEX pipe = in 2 / 72 in 2 = 0.8%
44 RADIANT PANEL DESIGN STEPS Next, research the floor coverings Bare concrete? Carpet? Tile? What R-values?
45 RADIANT PANEL DESIGN STEPS Then the designer: Selects the pipe size 5 choices (3/8 to 1 ) Selects the pipe spacing Tighter spacing helps to avoid floor striping, requires lower water temperature, ensures better response time, may even protect sensitive flooring against hot spots Selects the maximum circuit lengths Calculates the water (fluid) temperature Less pipe density may require higher water temperature, may cause striping This step is done using software
46 RADIANT PANEL DESIGN: PIPE SIZE Pipe Size % Used Applications 3/8 10% Used in dry panel systems, joist-space, bathrooms 1/2 70% Most common for residential wet systems 5/8 9% Larger residential, small commercial wet systems 3/4 9% Most commercial, industrial systems 1 2% Very large commercial, industrial systems Table represents average usage of pipe diameters for radiant heating applications across North America
47 RADIANT PANEL DESIGN: PIPE SPACING Typical Pipe Spacing, using 3/8", 1/2" or 5/8" PEX pipes Residential Slab On Grade (thick pour) Residential Overpour (thin pour) Overpour with Tile Overpour with Carpet Overpour in Bathrooms Under Exterior Cabinets Under Interior Cabinets, Pantries Dry Panel Installation Joist-space installation Commercial Slab On Grade 6-8" Perimeter, 8-12" Occupied; 6 bathrooms See below: 6-9" spacing throughout to prevent striping 6-8" Perimeter, up to 12" Occupied, based on heat load (more pipe = more efficiency) 6" spacing throughout for high output 12" under all cold wall cabinets Usually no pipe here Usually 8" throughout 8 spacing throughout, with 16 joist centers Depends on heat loss, 12 typical (18 possible)
48 RADIANT PANEL DESIGN: CIRCUIT LENGTHS Typical Maximum* Circuit Lengths 3/8 : 250 feet 1/2 : 330 feet 5/8 : 400 feet 3/4 : 500 feet 1 : 500 feet *There is no absolute Maximum circuit length. The farther the fluid travels in the pipe, the colder it becomes The practical maximum circuit length depends on pipe diameter, heat loss for that circuit, and pump capability to keep the ΔT #3 within 20 F A faster flow rate or larger diameter pipe reduces the heatloss per foot of the fluid travelling through the pipe Larger pipe contains more fluid and more BTU s for each foot of pipe in the floor
49 STEP 3. HYDRONIC FLOW RATES CALCULATING THE FLOW RATE TO DELIVER THE REQUIRED BTU S Hydronic Flow Rate Formula: Units: BTU/hr FD x 60 x SH x T(fluid) = USGPM lb. x min x BTU x ºF gal hour lb x ºF F D = fluid density (of the mixture) S H = Specific heat of fluid (of the mixture) F D = 8.34 lb/gal for water, at 60 F S H = 1.0 BTU/lb( F) for water, by definition of a BTU T (fluid) = 20 F for most hydronic systems
50 HYDRONIC FLOW RATES Hydronic Flow Rate Formula (simplified for water): BTU/hr 8.34 x 60 x 1 x 500 x 20ºF = USGPM BTU/hr 10,000 = USGPM NOTE 1: US gallons are 3.8 l; Imperial gallons are 4.54 l, about 19% larger All hydronic tables and graphs are based on US Gallons (USGPM) NOTE 2: These values apply only to water systems. Antifreeze will change these calculations
51 Column height = 10 feet STEP 4: PIPE HEADLOSS How much pressure (head) is required to make the water flow at the required flow rate? Pressure is expressed in feet of water head CONVERSIONS: 10 foot head = 4.4 pounds per square inch (psi) 1 psi = feet of head System headloss values are found in tables and charts by the equipment manufacturers, such as: Pipes Heat sources Air eliminators Manifolds, etc.
52 STEP 4: PIPE HEADLOSS SAMPLE HEAD LOSS TABLE FOR PEX PIPES Flow Rate Flow Velocity 100 o F (38 o C) Water GPM ft/sec head loss/100 ft of pipe Pipe Size- 3/8" 1/2" 5/8" 3/4" 1" 3/8" 1/2" 5/8" 3/4" 1" Match flow rate with pipe size for headloss per 100 feet of pipe length
53 STEP 5: CHOOSING A CIRCULATOR INFORMATION NEEDED: Flow rate required (Step 3) Head loss to overcome at that flow rate (Step 4) PRINCIPLE: Select a circulator which meets or slightly exceeds the flow rate and headloss requirements of the hydronic system, without going under Avoid oversizing circulators by more than 10% over actual system needs
54 STEP 5: CHOOSING A CIRCULATOR - All circulators have tested performance curves available - Find intersection of x GPM and y feet of head loss to check if a given circulator is correct - See how the system curve matches circulator performance curve - System curve must fall to left of the circulator performance curve (inside) - Ideally, the system curve will be in the middle and to the left of the circulator curve
55 RADIANT HEATING DESIGN PROCESS Step 1 1a: Heat Loss of space (this also gives Heat Source sizing requirements) 1b: Radiant Panel Heating Requirement (BTU per hour per ft2) 1c: Required Floor Temperature (how warm does the floor need to be?) Step 2: Radiant Panel Design: Determine PEX pipe size, pipe spacing, circuit lengths, and water temperature (designers will have several options) Step 3: Determine Flow Rates for circuits and the entire system Step 4: Determine Head Loss requirements Step 5a: Choose Circulator (pump) to meet Flow Rate and Head Loss requirements 5b: Size Expansion tank for the volume of the system
56 NOTES ON SOLID HARDWOOD FLOORING OVER RFH POTENTIAL DESIGN ISSUE: With some species/brands of solid hardwood, the Maximum acceptable design temperature on the bottom of the board is as low as 85ºF This would produce a maximum floor surface temperature of 77ºF on the top of the hardwood board 77ºF Floor Temp. = 18 BTU/hr(ft 2 ) output This is a safe limit for design with solid hardwood over radiant floor heating, when the hardwood selected has a Maximum acceptable design temperature on the bottom of the board of 85ºF MOST HARDWOOD CONCERNS ARE BASED ON TWO ISSUES: Poorly design and controlled radiant systems with excessive water temperatures Hardwood floors installed when thermal mass is still wet, or before acclimation to the space
57 NOTES ON SOLID HARDWOOD FLOORING OVER RFH POTENTIAL SOLUTIONS: Installers can control the under-floor hardwood temperature with the programmable floor sensor thermostat and remote floor sensor set into the floor Program Max Floor Temp. = 85ºF Installer should use tighter pipe spacing to reduce localized hot spots Flooring contractor should use Quarter Sawn hardwood boards, Maximum 2 1/2 wide Flooring contractor must ensure that the hardwood acclimates to the space/relative humidity for 2+ weeks before installation (even longer with wet overpour) Add dry panel heating to walls or ceiling as supplemental heat source
58 NOTES ON SOLID HARDWOOD FLOORING OVER RFH POTENTIAL SOLUTIONS: specify flooring tolerant of the required temperatures, such as engineered hardwood floors Solid Hardwood Flooring Engineered Hardwood Flooring
59 NOTES ON CARPET AND UNDERPAD OVER RFH POTENTIAL DESIGN ISSUE: Thick carpet and inappropriate underpad insulate a heated floor, trapping the heat inside unless high water temperature is utilized. Inappropriate underpad may also fail prematurely over a heated floor POTENTIAL SOLUTIONS: Thinner carpet has lower R-value and conducts heat better Select the thinnest carpet which is acceptable to the customer Synthetic rubber (SBR*) underpad is recommended for use over radiant systems Be sure to select flat SBR underpad (not rippled) *Styrene Butadiene Rubber
60 NOTES ON CARPET AND UNDERPAD OVER RFH POTENTIAL SOLUTION: A high quality underpad is better for the carpet, is more comfortable underfoot and is a more efficient choice when working with a radiant floor SBR underpad is recommend for use over radiant systems Longer-lasting Conducts heat better Typical thickness is 7/16 Will handle the temperatures
61 RADIANT HEATING DESIGN FUNDAMENTALS REVIEW Step 1 1a: Calculate Heat Loss of space (gives Heat Source size) 1b: Radiant Panel Heating Requirement (BTU per hour per ft²) 1c: Required Floor Temperature - how warm does the floor need to be? Step 2: Radiant Panel Design: Determine PEX pipe size, pipe spacing, circuit lengths, and water temperature (designers have several options) Step 3: Determine Flow Rates for circuits and the entire system Step 4: Determine Head Loss requirements Step 5: Choose Circulator (pump) to meet Flow Rate and Head Loss requirements
62 RADIANT CONTROLS SELECTION Control theory Zoning components Thermostatic mixing Outdoor reset control Offer the most appropriate control for customer satisfaction and system performance. There are many choices...
63 RADIANT CONTROLS THEORY TYPE I: HEAT SOURCE CONTROLS THE FLUID TEMPERATURE 108 F Circulator Adjustable Temperature Heat Source (outdoor reset) Primary loop 88 F Load (s) at same water Temperature Zoning elements control the flow via manifold actuators or by the circulator No water temperature mixing devices: Heat source controls its own output temperature Fixed output temperature (set for highest annual demand) Integrated outdoor reset control Actuators or zone valves control flow
64 RADIANT CONTROLS THEORY TYPE II: HEAT SOURCE FLUID TEMPERATURE MUST BE REDUCED BEFORE THE FLOOR 180 F Circulator 108 F High Temperature Heat Source Primary loop Mixing Device Secondary loop Low Temperature Load Zoning elements control the flow via manifold actuators or by the circulator 140 F 88 F Water temperature mixing device options: 3-Way Thermostatic Mixing Valve (TMV) 2-Way Thermostatic Injection Valve Floating Action (motorized 3- or 4-Way) Mixing Valve Variable Speed Injection Pump Mixing
65 ABNA - NC RFH SY STEMS 40 / 99 24V 3 W ABNA - NC RFH SY STEMS 40 / 99 24V 3 W ABNA - NC RFH SY STEMS 40 / 99 24V 3 W ABNA - NC RFH SY STEMS 40 / 99 24V 3 W RADIANT CONTROLS THEORY FLOW CONTROL THROUGH ZONING T-Stats 24 V Actuators 24 V Zone Valves REHAU Zone Box or REHAU Outdoor Reset Control
66 RADIANT FLOW CONTROL - ZONING CONTROLS THERMOSTATS AND ACTUATORS: Allows control of each room or zone Allows different temperatures throughout rooms Accommodates solar gain or high occupancy Must use special radiant thermostats different calibration than air stats One thermostat is a zone Control flow through actuators on balancing manifolds Coordinate multiple thermostats and actuators in a zone control module
67 RADIANT FLOW CONTROL - ZONING CONTROLS ELECTRIC THERMAL MANIFOLD VALVE ACTUATOR: Wax melt thermal motor No solenoid, no motor or gears Normally Closed position Operates with 24 VAC power Blue-Brown are the power wires (24 VAC) Green-Green are the end switch wires Electrical circuit is completed when the actuator opens fully Will complete another electrical circuit to activate pump relay Red Tab holds actuator open to ease installation and is then thrown away
68 RADIANT ZONE CONTROL MODULE LOW-VOLTAGE 24 VAC WIRING BOX: Connect all thermostats and actuators into one box 4-zone Zone Control Module Low-voltage 24 VAC input/output Controls actuators based on input from up to 4 thermostats ( zones ) Mount nearby manifolds Run thermostat wire to the manifold location into the zone control module
69 RADIANT THERMOSTATIC TEMPERATURE CONTROL 3-WAY THERMOSTATIC MIXING VALVE APPROPRIATE ONLY FOR SMALL SYSTEMS, LESS THAN 30,000 BTU/HR: Valve blends supply and return water to provide fixed output temperature Simple and fairly accurate Fixed output temperature must be set manually Not weather-responsive Water temperature may be too warm or too cold Probably too warm for most days Limited flow capacity is based on low Cv ratings 3/4 Valve Cv Valve Cv 3.0 Exceeding the Cv rating increases headloss and possibility of noise Note: Cv = Controlled Volume = 1 psi loss
70 OUTDOOR RESET CONTROL WEATHER-RESPONSIVE CONTROL OF WATER TEMPERATURE FOR HYDRONIC SYSTEMS ADVANTAGES: Comfort: Fast response to changes in heat loss Prevent room temperature overshoot Steady room temperature Control: Can integrate with room zoning Boiler protection, floor protection You may need 2- or 3-temperature systems Flexibility: Can control high-temp. and low-temp systems simultaneously Efficiency: Reduced water temperatures Increased cycle times, better equipment life Reduced thermal expansion noise and cycling
71 OUTDOOR RESET CONTROL WEATHER-RESPONSIVE CONTROL OF WATER TEMPERATURE FOR HYDRONIC SYSTEMS FUNCTIONS: Outdoor reset control determines the Target Supply water temperature based on Outdoor Air temperature at that moment in time This is based on design information for that project: Outdoor design temperature Water supply temperature at design conditions Minimum/maximum water supply temperature Minimum boiler return water temperature (if applicable) Outdoor reset control ensures that the heat input matches heat loss at any moment in time Not too cold, not to hot, just right Reset Curve calculates the target water temperature Outdoor reset control also protects boiler against cold return temperatures Outdoor reset control also protects sensitive flooring against hot supply temperatures
72 OUTDOOR RESET CONTROL TWO VARIATIONS: Floating action output 3- or 4-way motorized valve output Motor floats the valve back-and-forth Motor is necessary to control valve Variable Speed Mixing Control Variable speed pump output operates an injection pump All use outdoor temperature sensors to reset system target water temperature
73 OUTDOOR RESET CONTROL- COMPLETE SYSTEM COMBINE WATER FLOW CONTROL AND WATER TEMPERATURE CONTROL FOR AN INTEGRATED SYSTEM: Components: Manifolds Mixing Valve Outdoor Reset Control Outdoor Sensor Pipe Temp. Sensors Thermostat
74 Course Summary NOW THE DESIGN PROFESSIONAL WILL BE ABLE TO: Describe the advantages of using radiant floor heating (RFH) technology List several application options for RFH including residential, commercial, civic, industrial, and institutional applications Follow the design process for radiant heating systems to determine heat loss, floor temperatures, piping layouts, and fluid temperatures Explain the basic control systems incorporated in radiant heating systems
75 RADIANT HEATING DESIGN AND CONTROLS AN AIA CONTINUING EDUCATION PROGRAM Credit for this course is 1 AIA HSW CE Hour Course reh23c
76 Ron Blank and Associates, Inc Please note: you will need to complete the conclusion quiz online at ronblank.com to receive credit SUSTAINABLE BUILDING TECHNOLOGY REHAU s sustainable building technology provides solutions for heating, cooling, snow and ice melting, plumbing, water supply, fire protection, fresh air supply, and the building envelope Lance MacNevin REHAU Inc Edwards Ferry Rd. Leesburg, VA Lance.MacNevin@rehau.com
Applications and Piping Strategies for Condensing Boilers - Introduction
Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control
More informationGETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS
GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual
More informationLOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC
LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER
More informationThe electrical wattage needed by the circulator is:
The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data
More informationbout your HOUSE Hydronic Radiant Floor Heating CE 4
A bout your HOUSE CE 4 Long ago, the Romans used radiant floor heating in their bathhouses. For centuries, the Koreans heated their royal palaces and traditional homes in this manner. Today, radiant heating
More information- Data Brochure Universal Reset Module 422
- Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationEASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How hydronic heating systems work Advantages Disadvantages Design alternatives Baseboard convectors Residential Hydronic Heating A residential
More informationREHAU Radiant Heating Systems. A warm welcome
REHAU Radiant Heating Systems A warm welcome A warm welcome REHAU Radiant Heating Systems Discover the comfort Your home provides an escape from this busy world. It s a place to build memories with family
More information- Data Brochure Universal Reset Module 423
- Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More information- Essay Control Functions and Benefits
- Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,
More informationRADIANT HEAT. Construction Automotive Industry
RADIANT HEAT A warm floor MAKES a warm home www.rehau.com Construction Automotive Industry Discover the comfort Your home provides an escape from this busy world. It s a place to build memories with family
More informationCirculators high efficiency ECM Circulators
Circulators high efficiency ECM Circulators Circulators high efficiency ECM Circulators Small ECM circulators now available in North America Grundfos Alpha: Provides constant and proportional differential
More information6 PIPING ARRANGEMENTS
6 PIPING ARRANGEMENTS The design of a panel radiator based heating system involves selection of a piping system, pipe sizes, overall design temperature drop, required flow rates and desired type of system
More informationAdvanced Hydronic Control Solutions for Geothermal heat pumps
Advanced Hydronic Control Solutions for Geothermal heat pumps Table of Contents HydroLogic Control Panels................................................................ 4 HydroLogic Control Panel Features.........................................................
More informationUNDERFLOOR HEATING GUIDE
UNDERFLOOR HEATING GUIDE Bringing you the best underfloor heating in South Australia for 30 years. Introduction to Underfloor Heating Due to its supreme level of comfort and great heating efficiency, underfloor
More information2.A MANIFOLD SHUNTS MINI SHUNTS
2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,
More informationRadiant Floor Heating
PHRC Webinar Series Tuesday, December 12th @ 1pm Radiant Floor Heating Chris Hine Housing and Land Development Specialist Pennsylvania Housing Research Center 206B Sackett Building University Park, PA
More informationUFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas
UFAD and Displacement Ventilation Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas UFAD and DV Systems, Objectives: Understand Differences between: Well Mixed, Partially Stratified and Fully
More informationAmbient (ºF) Temperature Rise Above
Spec-00488 Heat CPH FX (763) Dissipation 422-2600 422-2211 in Electrical Enclosures Technical Thermal Management Information Heat Dissipation in Sealed Electrical Enclosures The accumulation of heat in
More informationYou thoughtfully chose each color, each fabric, every detail, all to give your home a feeling of warmth.
Radiant floor heating You thoughtfully chose each color, each fabric, every detail, all to give your home a feeling of warmth. Only to find that real warmth is hidden beneath the floor. A warm and cozy
More informationexperience We carefully design each individual installation to optimise performance Good underfloor heating explained
2.7m 23 1.8m Good underfloor heating explained Radiator versus Underfloor Heating 2.7m 1.8m 21 Radiator System Underfloor Heating System Hot air rises. The hotter the air, the quicker it rises. Radiators
More informationHeating Installation Guide published by
Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September
More informationHeat loss: the Reason for Heating
Greenhouse Heating Heat loss: the Reason for Heating Greenhouses loose heat quickly Materials used that need to transmit light don t have very good insulative qualities Northern greenhouses can loose more
More informationHot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT
Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.com Gary Klein, 2012 Efficiency
More informationOutdoor Reset Control Theory FULL versus PARTIAL reset
Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.
More informationRadiant Heating. Systems
O p t i m i z i n g t h e P e r f o r m a n c e o f Radiant Heating Systems Minimizing costly mistakes and maximizing a radiant project s performance by focusing on building and system efficiency Radiant
More informationProRadiant Controls, Valves and Actuators
214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation
More information"Best Practices in Modern Hydronic Heating - THE DETAILS
"Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r
More informationAIR CONDITIONING. Carrier Corporation 2002 Cat. No
AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)
More informationAugust 15, 2013 Page 1 of 19
Section C401 Application Compliance with C402, C403, C404 and C405 AND (either C406.2, C406.3 or C406.4) Compliance with C402, C403, C404 or C405 Section C402 Building Envelope (Climate Zone 5A) Space-Conditioning
More informationRESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators
RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING www.b Unique, slim-design baseboard radiators The RESCOM 2100 system is unlike traditional baseboard heating systems. Smooth flat panels are easily secured
More informationBest Practices for Condensing Boilers
ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at www.cleaverbrooks.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For
More informationAdelaide Homes Design Guide 4 - Winter warming
Adelaide Homes Design Guide 4 - Winter warming Adelaide's temperate climate means home warming is required during winter. There are many efficient heating systems. The most economical method, however,
More informationRadiant Snap-In Formed Metal Panels
Radiant Snap-In Formed Metal Panels Energy Efficient Comfortable Clean Quiet 395 West 1100 North North Salt Lake, Utah 84054 T EL (801) 292-0493 FAX (801) 292-9908 WATER PRESSURE DROP HEATING PERFORMANCE
More informationASHRAE JOURNAL ON REHEAT
Page: 1 of 7 ASHRAE JOURNAL ON REHEAT Dan Int-Hout Chief Engineer Page: 2 of 7 Overhead Heating: A lost art. March 2007 ASHRAE Journal Article Dan Int-Hout Chief Engineer, Krueger VAV terminals provide
More informationUsing Embedded Tube Radiant Cooling Systems to Maximize LEED Points
San Joaquin ASHRAE Chapter Using Embedded Tube Radiant Cooling Systems to Maximize LEED Points Devin Abellon, P.E. Business Development Manager Uponor November 4, 2010 LEED v3 new construction LEED Topic
More informationThe Art of Building Science
The Art of Building Science What is Building Science? Building Science seeks to apply the scientific fundamentals of building dynamics to the functional relationships between the house s components and
More informationA: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.
A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance. Q: How likely am I to run into this imbalance problem? A: It all
More informationRadiant Heating & Cooling for Commercial Buildings
Radiant Heating & Cooling for Commercial Buildings Kaveesh Padiachy, PEng, PMP, LEED AP Business Development Manager Central Canada kaveesh.padiachy@uponor.com www.uponorpro.com/engineering Radiant Heating
More informationDear Hydronic Professional, Dear Hydronic Professional,
Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366
More informationHEAT EXCHANGER FORMULAS & EXAMPLE
Formulas for Heat Exchanger System using a Modulating Control Valve Definition of Terms and Units: E = Mean Heat Transfer Rate or Heat Load (Btu/hr) E D = Design Heat Load (Btu/hr) U = Overall Heat Transfer
More informationMascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing
Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,
More informationRadiant Lay-In Formed Metal Panels
Energy Efficient Comfortable Clean Quiet 395 West 1100 North North Salt Lake, Utah 84054 TEL (801) 292-0493 FAX (801) 292-9908 WATER PRESSURE DROP HEATING PERFORMANCE Head Loss in Head Loss in Feet of
More informationPRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division
INTRODUCTION PRESSURE-ENTHALPY CHARTS AND THEIR USE The refrigerant in a refrigeration system, regardless of type, is present in two different states. It is present as liquid and as vapor (or gas). During
More informationFundamentals of Hydronic Design
Radiant Based HVAC Systems Differential Pressure Fundamentals of Hydronic Design This educational material is copy written by Robert Bean, R.E.T., All Rights Reserved. If you wish to use this presentation
More informationCase Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx
Case Study: Furman University Charles H. Townes Center for Science Michael K. Mantai, PE, CCP President System WorCx AIA Quality Assurance Learning Objectives 1. Case study example of Chilled Beam technology
More informationDonʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted!
Donʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted! Hydronic heat emitters options for low energy use houses Most CONVENTIONAL
More informationA. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection
PAGE 238318-1 SECTION 238318 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationRadiant Heating & Snow Melting
Radiant Heating & Snow Melting Give Your Heroes the Comfort of Radiant WattsRadiant.com Radiant heating for comfort & efficiency Radiant heat provides numerous benefits, including improved comfort, reduced
More informationInDEX. A Technical Journal from Caleffi Hydronic Solutions
Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationEnergy Management and Controls
As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try
More informationDisplacement Ventilation
Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution
More informationUpdate Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South
3/5/2018 1 Update Dedicated Heat Recovery Chiller Technology Don Frye Gulf South Good design is an intentional act Begin with the end in mind Basic Bldg Tenants IAQ (low VOC & CO 2 ) Controlled Temp &
More informationA/C Cooling Load calculation and measurement
Testo Inc. 40 White Lake Rd. Sparta NJ 07871 (800) 227-0729 A/C Cooling Load calculation and measurement When we talk about sizing an air conditioning appliance (tons of cooling, BTU/h or KW), we are specifying
More information- Data Brochure Universal Reset Control 364
70 7 8 9 - Data Brochure Universal Reset Control 364 D 364 07/01 The Universal Reset Control 364 is designed to maximize the comfort and efficiency provided by a hydronic heating system. The control automatically
More informationASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee
ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC
More informationResidential Geothermal Technology. Eco-$mart, Inc. Distributed by: TOLL FREE:(888) FAX:(941)
Residential Geothermal Technology Geothermal Heating and Cooling Distributed by: Eco-$mart, Inc. TOLL FREE:(888)329-2705 FAX:(941)377-9460 info@eco-smart.com www.eco-smart.com 1 Residential Geothermal
More informationCONTROLLED CHILLED BEAM PUMP MODULE
FIRST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed pump uses a
More informationMaincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?
UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating (UFH) is not a new concept; it was brought to Britain about 2,000 years ago by the Romans. Their heating technique was to allow hot gasses from
More informationHydronic Product & Application Catalog
Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose
More informationViega Concrete System Installation Manual
Viega Concrete System Installation Manual The global leader in plumbing, heating and pipe joining systems Welcome By choosing to install a Viega Concrete System, you have joined the ranks of heating system
More informationSession: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island
Session: HVAC 101 HVAC 101 Steve Sain Sain Engineering Associates, Inc. August 9, 2016 Rhode Island Convention Center Providence, Rhode Island Why? 2 Acknowledgements 3 Disclaimer I m gonna shoot down
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationRadiant Cooling Nonresidential HVAC Stakeholder Meeting #2
1 Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program Abhijeet Pande Heschong Mahone Group, Inc. Kristin Heinemeier Western Cooling Efficiency
More information- Data Brochure Mixing Control 360
- Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The
More informationReinventing Energy Efficiency WARMNESS.
Residential WATER2WATER WT SERIES Reinventing Energy Efficiency WARMNESS www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction
More informationTHE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)
THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and
More informationEngineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.
VAV Diffusers lease refer to the rice Engineer s HVAC Handbook for more information on VAV Diffusers. Diffuser Types Ceiling Diffusers Conventional air distribution systems typically group several rooms
More informationSolar Thermal Planning Worksheet Date: / /
Solar Thermal Planning Worksheet Date: / / Preliminary Report By: Project Name Address Installation Location or City State Contractor or Agent: Address: Telephone / Fax: Email: Project: New Construction
More informationprestige Control Application Supplement - TriMax
prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions
More informationNET ENERGY WATER LOOPS A clear path to net zero energy buildings
Presents NET ENERGY WATER LOOPS A clear path to net zero energy buildings Alan Niles WaterFurnace International This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer
More informationWelcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018
Welcome High Performance Mechanicals for Houses That Work Energy Design Conference - Duluth, MN February 21 st, 2018 Local Sponsor EEBA National Education Partners CEU s 4 In accordance with the Department
More informationEco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps
(/) Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps The perfect combination for any heat pump or geothermal hydronic heating system. Eco Ultra is the only buffer storage tank that is also a fully
More informationScience 7. Unit 3. Heat and. Temperature
Science 7 Unit 3 Heat and Temperature Name:_ Class:_ TOPIC 1 REINFORMCEMENT Putting Thermal Energy to Work Goal Develop ways to classify natural and manufactured structures. BLM 3-1 When do you use thermal
More informationVentilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.
Ventilation ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce /NDCommerce /NDCommerce /NDCommerce /NDCommerce WHATS NEW IN ASHRAE 62.2 2016 Controls (Override) Shutoff for maintenance
More informationSUH-8 UNIT HEATERS. High Efficiency Heating Equipment
SUH-8 UNIT HEATERS High Efficiency Heating Equipment Efficient Heating Solutions for all Applications Sterling unit heaters provide efficient heating solutions for all residential and commercial applications.
More information17 Interior Climate Control
17 Interior Climate Control 17.1 Air is leaking through or around windows and/or exterior doors. Windows and doors shall be installed to minimize air leakage in accordance with the Alberta Building Code.
More informationFREQUENTLY ASKED QUESTIONS
HEAT PUMP INVERTER R-410A All-in-one, all year round heating, cooling and domestic hot water supply solution FREQUENTLY ASKED QUESTIONS WANT TO KNOW MORE? AVERAGE ANNUAL CO 2 EMISSIONS Daikin Altherma
More informationHVAC 101. The Basics of Heating, Ventilation and Air Conditioning
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning HVAC Heating, Ventilation and Air Conditioning Provides comfort for people Allows humans to exist under adverse conditions. Comfort Comfort
More informationA hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.
Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the
More informationSUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017
SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017 The Residential Energy Code Worksheet is a tool to help you plan your energy code needs for new or remodeled homes,
More informationHeat Pumps COMFORT NEED IT. When You
Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating
More informationQUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS
OIL-TO-AIR HEAT EXCHANGERS Description BUCR Series Oil-To-Air Heat Exchangers 1 BUCR Series Oil-To-Air Heat Exchangers He The BUCR Series heat exchangers are designed to stabilize the oil temperature and
More informationSAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.
Chapter 4 Variable-speed pumps. A variable-speed pump varies the flow rate by maintaining a constant pressure differential as zone valves open and close. A sensor measures the difference in pressure between
More informationAir-to-Water Heat Pumps + Boilers A Dynamic Duo
Authored by John Siegenthaler September 2016 Edition Air-to-Water Heat Pumps + Boilers A Dynamic Duo Electrically powered heat pumps, available in many varieties, will play an increasingly important role
More informationWelcome To. System Benefits With ECM PUMPS
Welcome To System Benefits With ECM PUMPS Hydronic System Efficiency Should we be focusing on more than just the heat source? 2 The hydronic heating industry has put there main focus on the heat source
More informationConstruction Automotive Industry
FOR IMMEDIATE RELEASE CONTACT: REHAU Communications Department Susanne Martin sue.martin@rehau.com Corrie Neukirchner cordula.neukirchner@rehau.com (703) 777-5255 REHAU Radiant Heating and Cooling, Plumbing
More informationRESNET HERS Rater Sample Test Questions 2
RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space
More informationIDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions
IDL20e (2 way discharge) IDS60e ( way discharge) Frequently Asked Questions UDI (vertical discharge) Inffusers INFFUSER FREQUENTLY ASKED QUESTIONS The following are frequently asked questions (FAQ s) on
More informationJim Aswegan Chief Engineer
Displacement Ventilation Jim Aswegan Chief Engineer Displacement Ventilation Systems Comfort & Contaminate Control DV Concepts & System Benefits Outlet Types and Air Patterns Example l Space Layouts Displacement
More informationHydronic & HVAC Control Systems
tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better
More informationBetter Design, Better Control, Better Systems.
Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning
More informationThermal Energy Worksheets
Thermal Energy Worksheets Say Thanks to the Authors Click http://www.ck12.org/saythanks (No sign in required) To access a customizable version of this book, as well as other interactive content, visit
More informationFundamentals of Hydronic Design
Radiant Based HVAC Systems www.healthyheating.com Dynamic Pressure www.healthyheating.com This educational material is copy written by Robert Bean, R.E.T., All Rights Reserved. If you wish to use this
More informationDisplacement Ventilation in Classrooms
TWO DIFFUSERS, THE WHITE COLUMNS ON EACH SIDE OF THE WHITEBOARD, PROVIDE COOL SUPPLY AIR TO THE DEMONSTRATION DV CLASSROOM. THE DV CLASSROOM DEMONSTRATION FEATURED A CUSTOMIZED ROOFTOP HVAC UNIT. Displacement
More informationModule 1: Introduction to Radiant Cooling. Pierre Jaboyedoff
Module 1: Introduction to Radiant Cooling Pierre Jaboyedoff Module 1: Introduction to Radiant Cooling Heat Transfer Basics Human Body Heat Exchange Radiant Cooling Basics Radiant Cooling Suitability? Radiant
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationGeothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal
Geothermal Heating and Cooling Using Ground Source Heat Pumps Prepared by: Steven Forrester, P.E. Principal A Little History on Geothermal and Heat Pumps Lord Kelvin came up with the idea for heat pumps
More informationCTI Sponsored Educational Program
Presented By: Kent Martens SPX Cooling Technologies, Inc. Slide No.: 1 CTI Mission Statement To advocate and promote the use of environmentally responsible Evaporative Heat Transfer Systems (EHTS) for