VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)

Size: px
Start display at page:

Download "VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)"

Transcription

1 Engineering Manual R47C Data VK 3-3 Tons Vertical Comfort Cooling A/C s & Heat Pumps Features & Benefits 3 to 3 Ton Capacities Comfort Applications - General Office Spaces - Retail Stores - Restuarants - Factories & Warehouses Compact Vertical Floor Mounted SCAV Self-Contained & Split DX Air, Water & Glycol Cooled, Heat Pumps & Economizers Energy Saving Options - Variable Frequency Drives for VAV Applications - Air Side Economizers - Water Side Economizers 3 to 3 Tons Floor Mounted Comfort A/C s (Modular for Rigging Purposes!) Modular for Rigging Purposes &... More! VK MEA229-6-E Approved VK Veritical Cooling Comfort air conditioners (AVK-R7-L25) 1

2 AboveAir Air INTRODUCTION - VK Vertical SCAV Air VK vertical floor mounted air conditioners are the reliable solution to your comfort cooling control needs. Available in a wide variety of cooling methods and cabinet configurations including a full range of options, AboveAir Air A/C s are a step above! R47c or Optional R41a Refrigerant Modular For Rigging Purposes Packaged & Split Systems Top or Front Evap Air Discharge Variety of cooling methods Air Side and Water-Glycol Economizers VAV / VFD Application Option Flexible options and accessories Energy efficient operation Top Air Discharge Contents Introduction... 2 Features and Benefits... 3 Performance Data Electrical Data Guide Specifications Unit Dimensional Data Glycol Drycoolers Front Air Discharge Model Nomenclature Introduction

3 FEATURES & BENEFITS - VK Vertical SCAV AboveAir VK vertical comfort cooling SCAV A/C s are designed to meet your unique application dependent requirements. Select from a wide range of options and configurations: 3 to 3 Tons Splittable For Rigging VAV Option Package Hot Water Heat Electric Heat Steam Heat... and more!! MODULAR FOR RIGGING PURPOSES DX - AIR, WATER, GLYCOL COOLED plus HEAT PUMP & ECONOMIZERS Standard & Optional Features: Scroll Compressors (R47C) Adjustable Belt-Drive DWDI Blowers High Efficiency Air Filtration Low Ambient Head Pressure Control 2 & 3-way psig or 35 psig Water/ Glycol Cooled Regulating Valves Electric, Hot Water or Steam Heat Air, Water-Glycol Source Heat Pump Hot Gas Bypass Variable Frequency Drives (VFD) for VAV Accessories: Air Side Economizers w/ Enthalpy Controls Water-Glcyol Side Economizers Pumps Main Power Electrical Disconnects Firestats Smoke Detectors Remote Water-Leak Detectors Compressor Sound Jackets Glycol Pump Packages & Drycoolers... and more! MEA229-6-E Features & Benefits 3

4 Performance Data (VK-Vertical) - DX 4 To 1 Tons (R47C Data) Nominal Size 4 Tons 5 Tons 6 Tons 8 Tons 1 Tons Air Cooled Model VKA/KE/KH-48 VKA/KE/KH-6 VKA/KE/KH-72 VKA/KE/KH-96 VKA/KE/KH-12 AIR COOLED DX 8 F DB / 67 F WB, 5% RH Total 52,1 63,5 76,2 94,2 125, Sensible 36,4 45,3 55,5 7,7 94, 75 F DB / 62.5 F WB, 5% RH Total 47,8 58,6 7, 86,6 1, Sensible 36,2 45,1 55,4 7,5 92, Water Cooled Model VKW-48 VKW-6 VKW-72 VKW-96 VKW-12 WATER COOLED DX 8 F DB / 67 F WB, 5% RH Total 56,7 69, 87,9 17,6 132, Sensible 39,3 48,8 62,1 77,2 97,6 75 F DB / 62.5 F WB, 5% RH Total 51,4 63,8 8,1 97,7 126,8 Sensible 38,7 46,4 61, 75,7 13,4 Glycol Cooled Model VKG-48 VKG-6 VKG-72 VKG-96 VKG-12 GLYCOL COOLED DX 8 F DB / 67 F WB, 5% RH Total 49,1 6,1 75,7 92,7 1,8 Sensible 36,4 45,2 57,1 71,4 85,6 75 F DB / 62.5 F WB, 5% RH Total 44,5 54,8 68,4 83,9 15,3 Sensible 35,5 44,2 55,9 69,9 83,9 ALL DX MODELS GENERAL SHARED DATA Electric Heater (Duct Mounted, Separately Powered) - includes evaporator motor heat, (Optional) Capacity 52,9 53,49 54,63 55,78 75,135 KW Stages NO Blower / Motor - Belt Drive, DWDI Centrifugal Airflow Rate CFM 1,6 2, 2,4 3,2 4, E.S.P. IN WG Blower Motor HP 3/ Blower Diameter IN 12 X 9 12 X 9 12 X 9 X 1 X 1 Coil - Aluminum Fin, Copper Tube Rows NO Face Area FT Filters - 3% Dust Spot Efficient Nominal Size (NO) IN (2) 16 x 24 x 2 (2) 16 x 24 x 2 (2) 16 x 24 x 2 (3) 16 x 25 x 2 (3) 16 x 25 x 2 Compressor - Heat Pump Duty Hermetic Qty., Horespower (NO) HP (1) 4. (1) 5. (1) 6. (2) 4. (2) 5. Connection Sizes Drain FPT IN 3/4 3/4 3/4 3/4 3/4 Approximate Unit Weights VKA-( ) LBS ,2 1,225 VKE-( ) LBS ,5 1,75 VKH-( ) LBS VKW & VKG-( ) LBS ,1 1,125 4 Performance Data

5 Performance Data (VK-Vertical) - DX 4 To 1 Tons (R47C Data) Heat Rejection Data Nominal Size 4 Tons 5 Tons 6 Tons 8 Tons 1 Tons Model Size AIR COOLED DX WATER COOLED DX GLYCOL COOLED DX DX - AIR COOLED CONDENSER DATA Packaged or Split Horizontal & Vertical Indoor (Optional Outdoor), Centrifugal Blower Air Cooled Condensing Unit Data Model VKA-48 & XCU/VCU-48 VKA-6 & XCU/VCU-6 VKA-72 & XCU/VCU-72 VKA-96 & XCU/VCU-96 VKA-12 & XCU/VCU-12 Air Flow Rate CFM 2,5 3,2 3,9 4, 6,5 IN ESP Blower Motor HP 1 1-1/ Blower Diameter IN 12 x x x 12 x x Blower Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Coil Face Area FT Rows NO DX - WATER COOLED CONDENSER DATA Water Cooled Data - % Glycol Solution, THR & GPM at 8 F DB/67 F WB Cooling Capacity Model VKW & VWU-48 VKW & VWU-6 VKW & VWU-72 VKW & VWU-96 VKW & VWU-12 Total Heat of Rej. 68,77 84,36 111,68 131,76 162, F EWT GPM Water Press. Drop FT WG Water Reg. Valve 2-Way, psig - factory installed, (3-way & High Pressure Valves are Optional) DX - GLYCOL COOLED CONDENSER DATA Glycol Cooled Data 4% Ethylene Glycol, THR & GPM at 8 F DB/67 F WB Cooling Capacity Model VKG & VGU-48 VKG & VGU-6 VKG & VGU-72 VKG & VGU-96 VKG & VGU-12 Total Heat of Rej. 64,5 79,21 15,2 122,73 4,6 11 F EGT GPM Glycol Press. Drop FT WG Glycol Reg. Valve 2-Way, psig - factory installed, (3-way & High Pressure Valves are Optional) Connection Data Nominal Size 4 Tons 5 Tons 6 Tons 8 Tons 1 Tons Model Size AIR COOLED WATER COOLED DX - AIR COOLED REFRIGERANT (R47C) CONNECTION DATA DX Air Handling Units - (VKH models) Liquid Line OD IN (1) 3/8 (1) 3/8 (1) 1/2 (2) 3/8 (2) 3/8 Suction Line OD IN (1) 7/8 (1) 7/8 (1) 7/8 (2) 7/8 (2) 7/8 Indoor / Outdoor Horizontal & Vertical, Centrifugal Blower Remote Air Cooled Condensing Units - (XCU & XVU models) Liquid Line OD IN (1) 3/8 (1) 3/8 (1) 1/2 (2) 3/8 (2) 3/8 Suction Line OD IN (1) 7/8 (1) 7/8 (1) 7/8 (2) 7/8 (2) 7/8 DX - WATER COOLED CONDENSER CONNECTION DATA Water Cooled Data % Glycol Solution, (VKW & VWU models) Water IN/OUT OD IN 7/8 7/8 1 1/8 1 1/8 1 1/8 GLYCOL COOLED DX - GLYCOL COOLED CONDENSER CONNECTION DATA Glycol Cooled Data 4% Ethylene Glycol, (VKG & VGU models) Glycol IN/OUT OD IN 7/8 7/8 1 1/8 1 1/8 1 1/8 Performance Data 5

6 Performance Data (VK-Vertical) - DX 12 To 25 Tons (R47C Data) Nominal Size 12 Tons Tons 2 Tons 25 Tons AIR COOLED DX WATER COOLED DX GLYCOL COOLED DX Air Cooled Model VKA/KE/KH-144 VKA/KE/KH-18 VKA/KE/KH-24 VKA/KE/KH-3 8 F DB / 67 F WB, 5% RH Total Sensible 75 F DB / 62.5 F WB, 5% RH Total Sensible 9,6 194, 244,3 36,7 112, 135,9 175,1 22,8 145, 175,9 221,9 278,6 114, 134,1 172,7 217,4 Water Cooled Model VKW-144 VKW-18 VKW-24 VKW-3 8 F DB / 67 F WB, 5% RH Total Sensible 75 F DB / 62.5 F WB, 5% RH Total Sensible 169,2 211,4 266,2 334,3 116,4 144, 185,5 233,5 4,6 193,3 244,3 36,4 114, 14,8 18,1 228,6 Glycol Cooled Model VKG-144 VKG-18 VKG-24 VKG-3 8 F DB / 67 F WB, 5% RH Total Sensible 75 F DB / 62.5 F WB, 5% RH Total Sensible 3, 189,4 239, 299,3 19,2 133,8 172,2 217,2 142,6 171,7 216,5 271,8 112,6 132,1 17,1 214,2 ALL DX MODELS GENERAL SHARED DATA E lectric Heater (Duct Mounted, Separately Powered) - includes evaporator motor heat, (Optional) Capacity Stages Blowers / Motors Airflow Rate E.S.P. Blower Motor Blower Dia., (Qty.) Coil Rows Face Area Filters - Nominal Size Compressors - 75,135 79,72 79,72 119,58 KW NO Belt Drive, DWDI Centrifuga l CFM 4,8 6, 8, 1, IN WG HP I N X, (2) X, (2) X, (2) X, (2) Aluminum Fin, Copper Tub e 3% Dust Spot Efficient Qty., Horespower Connection Sizes Drain Approximate Unit Weights VKA-( ) VKH-( ) VKW & VKG-( ) - NO FT ( NO) IN ( 4) 2 x 3 x 2 ( 4) 2 x 3 x 2 ( 4) 2 x 3 x 2 (8) 16 x 25 x 2 Heat Pump Duty SCROLL ( NO) HP ( 2) 6. ( 2) 7. 5 ( 2) 1. (2) FPT IN LBS 1,85 1,9 2,1 2,5 LBS 1, 1,2 1,2 1,5 LBS 1,75 1,75 1,75 2,35 6 Performance Data

7 Performance Data (VK-Vertical) - DX 12 To 25 Tons (R47C Data) Nominal Size Heat Rejection Data 12 Tons Tons 2 Tons 25 Tons Model Size AIR COOLED DX WATER COOLED DX GLYCOL COOLED DX DX - AIR COOLED CONDENSING UNIT DATA Packaged or Split Vertical Indoor (Opt Outdoor), Centrifugal Blower Air Cooled Condensing Unit Data Model VKA & VCU-144 VKA & VCU-18 VKA & VCU-24 VKA & VCU-3 Air Flow Rate Blower Motor Blower Dia., (Qty.) Blower Type Coil Face Area Rows Water Cooled Data CFM 7,2 9, 13,, IN ESP HP I N NO x, (2) x, (2) x, (2) x, (2) Centrifuga l Centrifuga l Centrifuga l Centrifuga l FT NO DX - WATER COOLED CONDENSER DATA % Glycol Solution, THR & GPM at 8 F DB/67 F WB Cooling Capacity Model VKW & VWU-144 VKW & VWU-18 VKW & VWU-24 VKW & VWU-3 Total Heat of Rej. 85 F EWT Water Press. Drop 211,8 266,68 332,45 419,96 GPM FT WG W ater Reg. Valve 2 -Way, psig - factory installed, (3-way & High Pressure Valves are Optional) Glycol Cooled Data DX - GLYCOL COOLED CONDENSER DATA 4% Enthylene Glycol, THR & GPM at 8 F DB/67 F WB Cooling Capacity Model VKG & VGU-144 VKG & VGU-18 VKG & VGU-24 VKG & VGU-3 Total Heat of Rej. 11 F EGT Glycol Press. Drop 27,65 26, ,625 49,275 GPM FT WG G lycol Reg. Valve 2 -Way, psig - factory installed, (3-way & High Pressure Valves are Optional) Connection Data Nominal Size 12 Tons Tons 2 Tons 25 Tons Model Size AIR COOLED SPLIT WATER COOLED DX - AIR COOLED REFRIGERANT (R47C) CONNECTION DATA DX Air Handling Units - (VKH models) Liquid Line, (Qty.) OD IN 1/2, (2) 1/2, (2) 1/2, (2) 5/8, (2) Suction Line, (Qty.) OD IN 7/8, (2) 1-1/8, (2) 1-3/8, (2) 1-5/8, (2) Indoor / Outdoor, Centrifugal Blower Remote Air Cooled Condensing Units - (VCU models) Liquid Line, (Qty.) OD IN 1/2, (2) 1/2, (2) 1/2, (2) 5/8, (2) Suction Line, (Qty.) OD IN 7/8, (2) 1-1/8, (2) 1-3/8, (2) 1-5/8, (2) DX - WATER COOLED CONDENSER CONNECTION DATA Water Cooled Data - % Glycol Solutions, (VKW & VWU models) Water IN/OUT OD IN 1-3/8 1-5/8 2-1/8 2-1/8 GLYCOL COOLED DX - GLYCOL COOLED CONDENSER CONNECTION DATA Glycol Cooled Data 4% Ethylene Glycol (VKG & VGU models) Glycol IN/OUT OD IN 1-3/8 1-5/8 2-1/8 2-1/8 Performance Data 7

8 Performance Data (VK-Vertical) - Free-Cooling Tons Nominal Unit Size FE Free-Cool H2O Model: 4 Tons 5 Tons 6 Tons 8 Tons 1 Tons 12 Tons Tons 2 Tons 25 Tons VKW-48-FE VKW-6-FE VKW-72-FE VKW-96-FE VKW-12-FE VKW-144-FE VKW-18-FE VKW-24-FE VKW-3-FE Free-Cooling Coil Capacity w/ DX Water Cooled Systems 8 F DB / 67 F WB, 5% RH Total Sensible 75 F DB / 62.5 F WB, 5% RH Total Sensible 45 F EWT, % Glycol Solution 69,6 83,4 98,5 117,2 139,6 188,9 224,5 269,9 358,7 46,2 56, 66,2 81,5 98,2 13,1 7,1 195,9 254,2 54,2 65, 76,7 91,6 19,4 148, 176,4 214, 282,6 41,4 5,3 59,5 73,9 89,3 117,8 141,2 179,9 232, Flow Rate Coil Press. Drop GPM FT WG FE Free-Cool Glycol Model: VKG-48-FE VKG-6-FE VKG-72-FE VKG-96-FE VKG-12-FE VKG-144-FE VKG-18-FE VKG-24-FE VKG-3-FE Free-Cooling Coil Capacity w/ DX Glycol Cooled Systems 8 F DB / 67 F WB, 5% RH Total Sensible 75 F DB / 62.5 F WB, 5% RH Total Sensible 45 F EGT, 4% Ethylene Glycol Solution 53,5 65,8 81, 79, 99,8 144,3 178,9 22,8 33,1 39,7 48,9 59,2 66,7 82,8 112,5 139,1 177, 232,4 42,6 52,4 64,3 64,6 81,5 116,1 144, 179,7 243,4 36,6 45,1 54,4 62,9 78, 14,7 129,5 166, 2,9 Flow Rate Coil Press. Drop GPM FT WG Blower / Motor Airflow Rate E.S.P. Blower Motor Blower Dia., (Qty.) FE Free-Cooling Economizer Coil Rows Face Area FE Free-Cooling Control Valve Standard Valve Valve Size, (Cv) Max Opr Press Connection Sizes Free-Cool Water Drain - COMPONENT DATA: Belt Drive, DWDI Centrifuga l FREE-COOLING ECONOMIZER SYSTEMS CFM 1,6 2, 2,4 3,2 4, 4,8 6, 8, 1, IN WG HP 1 1-1/ I N 12 X 9, (1) 12 X 9, (1) 12 X 9, (1) X 1, (1) X 1 (1) X, (2) X, (2) X, (2) X, (2) - Aluminum Fin, Copper Tub e NO FT Field Installed 2-Way 2-Way 2-Way 2-Way 2-Way 2-Way 2-Way 2-Way 2-Way I N 1, (8.) 1, (8.) 1, (8.) 1, (8.) 1, (8.) 1-1/4, (8.) 1-1/4, (8.) 2, (14.) 2, (14.) PSIG OD IN 1-1/ 8 1-1/ 8 1-1/ 8 1-3/ 8 1-3/ 8 1-5/ 8 1-5/ 8 1-5/ 8 2 FPT IN 3/ 4 3/ 4 3/ 4 3/ 4 3/ Performance Data

9 Electrical Data (VK-Vertical) - DX 4 To 25 Tons Electrical Data ( = Full Load Amps / = Min Circuit Amps / = Max Overcurrent Protection) Nominal Tons 4 Tons 5 Tons 6 Tons 8 Tons 1 Tons VKA, Air Cooled Packaged Model Size /3/ /3/ VKH, DX Air Handling Unit 28/3/ /3/ VKE, Split Air Cooled Evap 28/3/ /3/ VKW & VKG, Water/Glycol Cooled Packaged 28/3/ /3/ VKW/G-FE, Water/Glycol Cooled w/ Free-Cooling 28/3/ /3/ Nominal Tons 12 Tons Tons 2 Tons 25 Tons VKA, Air Cooled Packaged Model Size /3/ /3/ VKH, DX Air Handling Unit 28/3/ /3/ VKE, Split Air Cooled Evap 28/3/ /3/ VKW & VKG, Water/Glycol Cooled Packaged 28/3/ /3/ VKW/G-FE, Water/Glycol Cooled w/ Free-Cooling 28/3/ /3/ Electrical Data 9

10 Electrical Data (VK-Vertical) - Remote s / ing Centrifugal Blower - DX Split - Air Cooled, Remote Condensing Units * see notes 1-3 below ( = Full Load Amps / = Min Circuit Amps / = Max Overcurrent Protection) VCU - Vertical, Indoor (Outdoor) Centrifugal Blower Air Cooled Remote Condensing Units XCU - Horizontal, Indoor (Outdoor) Centrifugal Blower Air Cooled Remote Condensing Units Power Supply 28/3/6 46/3/6 Power Supply 28/3/6 46/3/6 VCU-48 XCU VCU-6 XCU VCU-72 XCU VCU-96 XCU VCU-12 XCU VCU-144 XCU VCU-18 XCU VCU VCU Electrical Data

11 Electrical Data (VK-Vertical) - DX 4 To 25 Tons Propeller Fan - Remote Air Cooled s & Condensing Units XP1 & XP2 - Single & Dual Circuit, Outdoor Propeller Fan DX Air Cooled Remote s XPU - Outdoor Propeller Fan Air Cooled Remote Condensing Units Power Supply 28/1/6 277/1/6 28/3/6 46/3/6 Power Supply 28/1/6 277/1/6 28/3/6 46/3/6 Power Supply 28/3/6 46/3/6 XP1-6 XP2-18, 192, 24 & 264 XPU MFS MFS 2 MFS 2 XP1-96 XP2-3, 336, 372 & 432 XPU N/A N/ A MFS MFS 25 MFS 3 XP2-12 & 144 XPU MFS MFS 4 Notes: 1) = Full Load Amps; = Min Circuit Amps; MFS = Max Fuse Size 2) 277V provided via field installed step down transformer Qty. one XPU condensing unit is provided per circuit: VKH-48 units are provided with qty. 1 x XPU-48 units VKH-6 units are provided with qty. 1 x XPU-6 units VKH-72 units are provided with qty. 2 x XPU-36 units VKH-96 units are provided with qty. 2 x XPU-48 units VKH-12 units are provided with qty. 2 x XPU-6 units VKH-144 units are provided with qty. 2 x XPU-72 units VKH-18 units are provided with qty. 2 x XPU-96 units VKH-24 units are provided with qty. 2 x XPU-12 units XPU MFS XPU MFS XPU MFS 6 3 Approximate Unit Ship Weights (lbs.) UNIT SIZE VK TM Vertical s & Indoor Condensing Units VKA VKH VKE Approximate Unit Weight (LBS) VCU XCU XPU VKE VKW/VKG VKW/G-FE x , x , , 9 1, x 2 1,5 1,1 1, ,2 9 1, x 2 1,5 1,1 1, , , x 2 1,75 1,125 1, ,85 1,2 1,65 1, x 2 1,65 1,75 2, ,9 1,2 1,65 1, x 2 1,65 1,75 2, ,1 1,25 1,75 1, x 2 1,75 1,85 2,45 3 2,5 1,5 23 1, ,3 2,35 3, Remote Outdoor Air Cooled s Model Approx. Ship Wt. (LBS.) XP XP XP XP XP XP XP XP XP XP XP XP Electrical Data / Ship Wts 11

12 Guide Specifications - VK Vertical A/C s (4-25 Tons) 1. General 1.1 Summary 1.4 Quality Assurance The system shall be factory run tested prior to shipment. Testing shall include, but shall not be limited to: HiPot Test (2 times rated voltage plus 1 volts, per UL 1995 testing requirements). The system shall be designed and manufactured according to world class quality standards. 2. Products Overflow Safety Float Switches: The system shall be provided with a factory installed float type condensate overflow safety switches. The circuit shall be designed to shut down all system water producing operations in the event of an overflow condition Air Distribution These specifications describe the requirements for a comfort cooling vertical floor mounted packaged (or split) air conditioner. The system shall be designed to control space temperature and humidity. The air conditioning manufacturer shall design and furnish all equipment in the quantities and configurations shown on the project plans and specifications. The system shall be provided by AboveAir Technologies in Frederick, Maryland, USA. The system shall be listed by Intertek (ETL Semko), Inc. to conform with UL Std 1995 and be certified to CAN/CSA Std C22.2 No. 236 (Control No ). The system shall be NYC MEA229-6-E and Chicago Code Approved. The system model number shall be. 1.2 Design Requirements The system shall be an AboveAir Technologies VK-Vertical brand factory assembled and tested. The system shall be designed for indoor installation. The system shall have a total cooling capacity of BTU/H, and a sensible cooling capacity of BTU/H, based on an entering air condition of F DB, and F WB, % RH. The evaporator section shall be designed for Volt, Phase, Hertz main power supply. The remote condensing unit section (if applicable) shall be designed for Volt, Phase, Hertz main power supply. 1.3 Submittals Submittals shall be provided after manufacturer s receipt of a written purchase order and shall include: Detailed Performance and Electrical Data; Guide Specifications; and Dimensional Drawings. 12 Guide Specifications 2.1 Standard Features / All Systems Cabinet The cabinet chassis and access panels shall be powder-coat painted heavy gauge galvanneal steel for decor matching and corrosion resistance. Cabinet access panels shall rest in recessed pockets designed for minimum air leakage. The cabinet and access panels shall be lined with 2 lb/ft 2 high density sound and thermal insulation and sealed with self-extinguishing gasketing conforming to NFPA 9A and 9B. Splittable for Ease of Rigging: The cabinet shall be modular in design to allow for easy field break-down and reassembly of top evaporator and bottom condensing unit sections for rigging purposes. As a standard, the system shall ship from the factory as a one piece unit. (Note: VKA-144 thru 3 system ship in two sections from the factory for field assembly after rigging.) Component Access The unit shall be serviceable through front and side access panels with quickrelease quarter-turn fasteners Electrical System General: The electrical system shall conform to National Electric Code (NEC) requirements according to UL The control circuit shall be a 24 VAC low voltage circuit. The electrical system shall include, but not be limited to the following factory installed items: main power distribution block; grounding lug; 24 VAC control transformer; terminal connections; and motor controllers with start protection and circuit breakers for blower motors, compressors and each electric heater stage (if applicable). The system air distribution shall be configured for a draw-through air pattern to provide even air distribution and maximum coil performance Blowers / Motors The blower shall be the belt-driven centrifugal type, double width double inlet (DWDI), and statically and dynamically balanced to a minimum vibration level. The shaft shall be heavy duty steel with self-aligning ball bearings sized for an average 1, hours of service life. The blower motor shall be Hp at 1725 RPM (or 345 RPM) and mounted on an adjustable base. Belts shall be sized for 2% of the motor horsepower rating. Motors shall have overload protection and a minimum NEMA service factor of 1.. Blowers: The evaporator blower assembly shall be designed for inches external static pressure (e.s.p.) Blowers: (DX Air Cooled) The evaporator blower assembly shall be designed for inches external static pressure (e.s.p.) Air Patterns Top Discharge Front Discharge (standard) (optional) Top Evap Air Discharge: (standard) The evaporator shall be designed for free

13 Guide Specifications - VK Vertical A/C s (4-25 Tons) or ducted rear-unit return air inlet and top ducted air discharge. Air inlet and outlet connections shall include factory provided turned-out duct flanges for each of field duct connection. Front Evap Air Discharge: (optional) The evaporator shall be designed for free or ducted rear-unit return air inlet and front ducted air discharge. Air inlet and outlet connections shall include factory provided turned-out duct flanges for each of field duct connection. Packaged Air Cooled s: The integral air cooled condenser shall be designed for rear-unit ducted same-face air distribution. Air inlet and outlet connections shall include factory provided turned-out duct flanges for each of field duct connection Air Filtration The filter(s) shall be 2 inch thick pleated and rated for 3% dust spot efficiency (based on ASHRAE 52.1). The filter(s) shall be serviceable through a side access without shutting down the system. 2.2 Direct Expansion Systems DX - Coils Each compressor shall be the high efficiency, low sound Scroll type mounted on vibration isolators and located in a separate compartment out of the evaporator air stream to facilitate servicing while equipment is operating. Each compressor shall be complete with reversible positive oil pump, charging and service ports, internal spring isolation, and discharge gas vibration eliminator DX - Refrigeration Circuits Each refrigeration circuit shall be prepiped with type L refrigerant copper tubing. The refrigeration system shall include but not be limited to: expansion valve with external equalizer and rapid bleed-through capacity. Features shall include filter dryer, sight glass, pressure fittings and high pressure/low pressure safety cutouts. 2.3 Standard Features / Individual Systems DX - Air Cooled Systems DX - Air Cooled (Self-Contained Systems) Models: VKA-( ) DX - Air Handling Unit (Split, DX Air Handling Unit) Models: VKH-( ) The system shall be a split indoor vertical floor mounted dx air handling unit designed for field connection to the specified remote condensing unit (air, water or glycol cooled). The air handling unit shall include, but not be limited to: evaporator coil; centrifugal belt-driven blower and blower motor; thermal expansion valve with rapid bleed port, shraeder service valves; main power distribution block; grounding lug; 24 Vac control transformer; individual blower motor contactors; and terminal strip. The air handling unit shall ship from the factory with a dry-nitrogen holding charge for field sweat (copper) connection and refrigerant charging DX - Air Cooled Remote Condensing Unit (Indoor/Outdoor Centrifugal Blower Configuration) XCU - Horizontal XVU - Vertical The system shall be an indoor horizontal ceiling mounted (opt. outdoor horizontal) or vertical floor mounted remote air cooled belt-driven centrifugal blower condensing unit. The remote condensing unit shall include, but not be limited to: condenser coil; centrifugal belt-driven blower and blower motor; compressor; sight glass; shraeder service valves; high & low refrigerant pressure switches; main power distribution block; grounding lug; 24 Vac control transformer; individual blower motor and compressor starters/ contactors; and terminal strip. The DX evaporator coil shall be constructed of copper tubes and aluminum fins. The system shall be designed for a draw-through air pattern for maximum heat transfer. Coil end-plates shall be hot dipped galvanized. The evaporator coil shall be mounted in an insulated stainless steel condensate drain pan Scroll Compressors The system shall be a self-contained, vertical floor mounted air conditioner with factory mounted integral dx air cooled condensing unit with belt-driven centrifugal blower. The condensing unit shall be sized for full heat of rejection at 95 F ambient and be capable of operation to F low ambient air temperature The system shall require only single point main power supply and ship from the factory with a full operating refrigerant charge. (Note-1: Low Ambient Control is Optional - see options for more detail.) The condensing unit shall be sized for full heat of rejection at 95 F ambient and be capable of operation to F low ambient air temperature. The condensing unit shall ship from the factory with a dry-nitrogen holding charge for field sweat (copper) connection. Guide Specifications 13

14 Guide Specifications - VK Vertical A/C s (4-25 Tons) DX - Air Cooled (Split Systems) Models: VKE-( ) The system shall be a split dx, vertical floor mounted evaporator section for connection to a remote air cooled condenser. The compressor(s) shall be located in the evaporator section. The evaporator shall included, but not be limited to: evaporator coil; centrifugal beltdriven blower and blower motor; thermal expansion valve with rapid bleed port, shraeder service valves; compressor(s), refrigerant filter-drier and sight-glass; main power distribution block; grounding lug; 24 Vac control transformer; individual blower motor contactors; and terminal strip. The system shall require only single point main power supply and ship from the factory with a dry-nitrogen holding charge for field sweat (copper) connection and refrigerant charging DX - Air Cooled Remote Condensing Unit (Outdoor Propeller Fan) XP_-( ) pressure control as application requires - see options for more detail.) DX - Water Cooled Systems DX - Water Cooled (Self-Contained Systems) Models: VKW-( ) The system shall be a self-contained, vertical floor mounted air conditioner with integral dx water cooled condensing unit. The system shall include a water cooled tube-in-tube coaxial condenser and factory installed head pressure controlling 2-way water regulating valve rated for psi w.w.p. The water cooled condenser shall be designed to provide the total required system heat of rejection at 85 F entering water temperature and 95 F leaving water temperature. Source water shall be provided by a remote water source (by others). The system shall require only single point main power supply and ship from the factory with a full operating refrigerant charge. (Note: Higher pressure and 3-way valves are optionally available, see option ) DX - Glycol Cooled Systems shall be provided by a remote glycol drycooler source (see AboveAir Technologies FluidCool drycoolers). The system shall require only single point main power supply and ship from the factory with a full operating refrigerant charge. (Note: Higher pressure and 3-way valves are optionally available, see option ) Glycol Pump Packages & Drycoolers FC_-( ) / PA-( ) Glycol condenser source shall be provided by a FluidCool brand remote air cooled glycol drycooler and Pump- All brand pump package. The glycol drycooler shall be the outdoor mounted propeller fan type complete with factory installed aquastat fan cycling controls, motor starters with overload protection and non-fused disconnect switch. The glycol pump package shall be a (single or dual) pump package designed for outdoor installation complete with individual pump motor starters. Dual glycol pump packages shall be provided with manual lead-lag switch and field installed flow switch for automatic switchover to backup pump upon loss of flow. An expansion tank and AirTrol air bleed fitting shall be factory provided for field installation. The system shall be an outdoor mounted remote air cooled direct-driven propeller fan(s) condenser. The remote condensing unit shall include, but not be limited to: condenser coil; direct drive propeller fan(s) and fan motor(s); close-meshed steel wire with vinyl coating fan guards; shraeder service valves; main power distribution block; grounding lug; drycontact interlock for evaporator 24 Vac control signal; fan motor starters/ contactors; and terminal strip. The condenser shall be sized for full heat of rejection at 95 F ambient and be capable of operation to F low ambient air temperature. The condenser shall ship from the factory with a dry-nitrogen holding charge for field sweat (copper) connection. (Note-1: Select F Fan Cycling or -2 F Variable Speed Fan Low Ambient head 14 Guide Specifications DX - Glycol Cooled (Self-Contained Systems) Models: VKG-( ) The system shall be a self-contained, vertical floor mounted air conditioner with integral dx glycol cooled condensing unit. The system shall include a glycol cooled tube-in-tube coaxial condenser and factory installed head pressure controlling 2-way glycol regulating valve rated for psi w.w.p. The condenser shall be designed to provide the total required system heat of rejection at 11 F entering glycol temperature and 12 F leaving glycol temperature based on 4% ethylene glycol solution. Source glycol The drycooler shall provide total heat rejection at a flow rate of GPM with F EGT and F LGT at F ambient air temperature. Each pump shall be Hp and shall be sized to provide Ft. w.g. total system head. The glycol solution shall be % (ethylene or propylene) by volume. The drycooler and pump package shall be designed for Volt, Phase, Hertz main power supply. (Note: See AboveAir Technologies Fluid- Cool indoor & outdoor glycol drycooler and PumpAll glycol pump packages engineering manuals for more information.)

15 Guide Specifications - VK Vertical A/C s (4-25 Tons) 2.4 Options Air Cooled - Low Ambient Control water / glycol regulating valve rated for psig w.w.p CONTROL OPTIONS MC-2, Advanced Microprocessor T/H Controller w/ Alarms F Ambient - Modulating Variable Spd Head Pressure Control (Centrifugal s) DT-21, 22 & 23 - Digital H/C Thermostat (7-day programmable) The system shall be provided with a MC- 2 advanced microprocessor based temperature and humidity controller with alarms. VFD Control Variable fan speed head pressure controls shall be factory installed for low ambient control to -2 F ambient. The variable fan speed control shall include, but not be limited to: motor Variable Frequency Drive (VFD); analog and digital refrigerant pressure transducers; compressor crankcase heaters; and cold-start time delay relay F Ambient - Fan Cycling (Propeller Fan s) Fan cycling controls shall be factory installed to the propeller fan condensing unit to allow for low ambient operation to F F Ambient - Variable Speed Fan (Propeller Fan s) Variable fan speed head pressure controls shall be factory installed to the direct-driven condenser blower motor to allow for low ambient operation to -2 F. Compressor cold start time delay relay and crankcase heater shall be factory installed with the -2 F low ambient control feature DX - Water/Glycol Cooled Reg. Valves 2-Way, psig Reg. Valve 3-Way, psig Reg. Valve 2-Way, 35 psig Reg. Valve 3-Way, 35 psig Reg. Valve System head pressure shall be controlled by a factory provided -way A remote wall mounted deluxe 7-day programmable heat pump ready thermostat with digital display shall be factory provided for field installation. The thermostat shall include FAN AUTO-ON, COOL-OFF-HEAT-EM (emergency heat), SET and PROG/MAN selector switches. (Note: 21 = 1-Stg H/C; 22 = 2-Stg H/C; 23 = 3-Stg H/2-Stg C.) MC-1 - Micro T/H Controller with Alarms The system shall be provided with a MC- 1 microprocessor based Temperature and Humidity controller with Alarms. Centered in the controller shall be a graphic LCD display with characters to show the operating mode, time, set points and actual readings. The temperature and humidity sensors shall be internal to the remote display. The controller shall be capable of three different set points: normal, temporary and night per day, 7 days per week. The controller shall include the following visual and audible alarm indications (if applicable): High and Low Temperature High and Low Humidity Dirty Filter Sensor Failure Common Alarm Failure The controller shall include the following system operations (if applicable): Fan - continuous or on demand Auto-restart upon power loss Remote stop/start connection Short cycle protection Cold start time delay Heat pump operation with aux. heat Guide Specifications Select Features/Benefits: 4x2 Character Liquid Crystal Alpha-numerical Display User Configurable Run-Time Hours Current Unit Mode Status Alarm Status Digital & Analog Inputs / Outputs Temperature Anticipation Remote Stop / Start Contact Summary Alarm Contact Automatic or Manual (selectable) Restart After Power Loss Sequential Load After Restart Recovery Delay Compressor Short Cycle Timers Cold Start Time Delay Security Password Access Self-Diagnostics Service Mode Unit Status Display The control system shall display current unit functions and room status (if applicable): Current Dry Bulb Temp Set Point Current Relative Humidity Set Point System ON/OFF Cooling Heating Humidifying Dehumidifying Reheating Actual Room DB Temperature Actual Room Relative Humidity Alarm Conditions: Alarm conditions activate an audible and visual indicator plus close a summary alarm dry contact connection. The control system shall alert to the following alarm conditions (if applicable): High Temperature Low Temperature High Humidity Low Humidity Sensor Failure Summary Failure Loss of Air Flow Dirty Filter High Head Press Smoke Detection Firestat Leak Detection Sensor Failure Loss of Power

16 Guide Specifications - VK Vertical A/C s (4-25 Tons) Digital & Analog Control Inputs / Outputs: The control system shall be capable of both digital (ON/OFF) and analog (proportional integral, PI) input and output control. Select MC-2 Options: Multi-Unit N+1 Sequencing BMS Communications Interface: ModBus RS485 Serial Connection BACnet over MS/TP (RS485 Serial) BACnet Over IP (Ethernet / EIA485) LonWorks FTT1 (RS485 Serial) HEAT OPTIONS Electric Duct Heater An electric duct mounted heater shall be factory provided for field installation. The duct heater shall be the open wire nichrome element type complete with individual heater stage starter/contactor, air flow switch and overheat safeties. The duct heater shall require a separate main power supply from the unit. The electric heat shall have a capacity of BTU/HR and a KW rating of KW, controlled in stages SCR Fired Electric Duct Heater The electric heat shall be controlled through a zero firing silicon control rectifier (SCR) with an extruded aluminum heat sink and solid state logic system to provide close dry bulb temperature control of the leaving conditioned air temperature. The electric heat shall have a capacity of BTU/HR and a KW rating of KW Steam Heat A Steam Heat system shall be provided complete with a factory installed aluminum fin, copper tube steam coil and field installed 2-way motorized steam control valve. Steam piping specialties shall be field provided. Steam shall be provided by a remote source at the specified temperature and pressure. The steam heat system shall have a rated capacity of psig saturated steam Hot Water Heat A Hot Water Heat system shall be provided complete with a factory installed aluminum fin, copper tube hot water coil and field installed 2-way motorized steam control valve. Hot water shall be provided by a remote source at the specified flow rate and temperature. The hot water heat system shall have a rated capacity of GPM, F EWT Heat Pump Option The system shall include a factory installed heat pump heating cycle including reversing valve and automatic defrost cycle (if appl.). The heat pump mode heating capacity shall be BTU/HR. 2.5 Accessories Pump A condensate pump shall be factory provided for field installation. The condensate pump shall be provided with dual internal float switches: one for pump operation initiation and the other for pump reservoir overflow safety. The pump shall be powered through an A/C unit main power fused terminal connection Hot Gas Bypass Systems Hot Gas Bypass To Inlet Each refrigerant circuit shall be provided with a factory installed hot gas (discharge) bypass valve. The hot gas bypass valve shall be designed to supply hot gas to evaporator inlet as required to provide coil freeze-protection and capacity modulation under low load conditions. (Note: 3 rd Line - Each circuit of a Split DX system with compressor located in condensing unit shall require a field installed copper hot gas bypass refrigerant line between the evaporator and condensing unit sections.) Hot Gas Bypass To Suction Line with Quench Valve (3 rd Line Not Required!) Each refrigerant circuit of the Split DX system shall be provided with a factory installed hot gas bypass system to include: hot gas (discharge) bypass; desuperheating quench; and hot gas & quench solenoid valves. The hot gas bypass system shall be designed to supply hot gas and liquid refrigerant to the suction line as required to provide coil freeze-protection and capacity modulation under low load conditions. All hot gas bypass components shall be factory installed and shall not require additional field refrigerant lines on split DX systems Suction-Line Accumulators Each refrigerant circuit shall be provided with a factory installed Suction-Line Accumulator to prevent liquid slugging of the compressor and excessive refrigerant dilution of the compressor oil during low load conditions. The accumulator shall return refrigerant and oil to the compressor at a sufficient rate to maintain both system operating efficiency and proper oil level. The accumulators shall be wrapped with a 1/2 closed-cell neoprene insulation to prevent sweating. 16 Guide Specifications

17 Guide Specifications - VK Vertical A/C s (4-25 Tons) Main Power, Non-Fused Disconnect A main power non-fused disconnect shall be factory provided for field installation. The disconnect shall be NEMA rated for indoor or outdoor installation as required Firestat A Firestat shall be factory provided for field installation in the return air duct and wired to the A/C unit electrical control panel. The Firestat shall shut-down all A/ C system operations upon sensing a high return air temperature condition Smoke Detector shall be provided to automatically vary system evaporator air volume based on a signal from the factory provided field installed static air pressure transducer. The A/C system shall be designed to maintain a constant leaving air temperature based on user adjustable set point temperature (eg.: 6 F DB). A/C system cooling capacity shall modulate via a factory installed modulating (-1 Vdc) hot gas bypass on the primary or lead refrigerant circuit. A field installed supply air temperature sensor shall provide input value signal to the MC-2 microprocessor controller for automatic modulating control of the hot gas bypass valve. Dual compressor/circuit systems shall also include a factory installed snap-acting type pressure regulating hot gas bypass system for capacity modulation and evaporator freezeprotection on the circuit DX Water/Glycol Cooled with Free Cooling Cycle VKW/G-( )-FE economizer shall be energized. The outdoor air control shall determine whether the outdoor air is suitable for free/economizer-cooling. If the outdoor air is suitable, mechanical cooling shall be locked out by the outdoor enthalpy control. The motor actuator shall be energized, operating the outdoor air and the return air dampers. The motor actuator shall be regulated by the mixed air sensor to maintain proper discharge air temperature. When outdoor air is not suitable for free/ economizer-cooling, the Economizer shall be locked out and the outdoor air damper shall maintain minimum position while the indoor fan is operating. Upon unit shutdown or power loss, the spring return motor actuator shall close the outdoor air damper. The Economizer shall be automatically locked out during the heat mode (if applicable). The Air Side Economizer shall include: prewired modulating spring return motor actuator, compressor lockout, minimum position potentiometer, outdoor air control (enthalpy), mixed air sensor, multi-tap transformer and damper linkage. A Smoke Detector shall be factory provided for field installation in the return air duct and wired to the A/C unit electrical control panel. The Smoke Detector shall shut-down all A/C system operations upon activation Remote Water Detector A remote water-leak detector shall be factory provided for field installation. The remote water-leak detector shall be wired to shut down all A/C unit water producing functions upon sensing a water leak. The system shall include a factory installed water/glycol free cooling cycle complete with economizer cooling coil, aquastat, automatic control logic and field installed 3-way control valve. The FE coil shall be capable of providing rated sensible capacity without compressor operation when entering water/glycol fluid temperatures are 45 F or below. (Note: 2-way DX/FE valve configurations are optionally available.) Air Side Economizer All Model Types The Air-Side Economizer and Controls shall ship separately from the unit for field installation Compressor Acoustic / Sound Jackets Each compressor shall be provided with a factory installed compressor sound jacket with snap closure system for ease of removal and reinstallation. Sound jackets shall have a noise reduction coefficient (NRC) of 85 per ASTM and C- 423 and a sound transmission lost (STC) of 11 per ASTM E VAV Supply Air Control (VFD w/ Modulating HGBP) VFD Control The system shall be designed for Variable Air Volume (VAV) application. A factory installed evaporator blower motor Variable Frequency Drive (VFD) with Proportional-Integral (PI) capabilities The system shall be provided with an Air- Side Economizer to include factory provided and field installed air side economizer mixing box and controls per the following sequence of control: On a call for cooling by the indoor space thermostat, the indoor fan and the Guide Specifications 17

18 Dimensional Data - DX Air Cooled, Vertical SCAV (4-6 Tons) DX - Air Cooled, Self-Contained - Top Evap Discharge Models: VKA-48, 6 & 72 (Single Compressor) 31." 16.".47" 16." 1." 4.34" 24.9" 4.6" 31.5" 1.69" 79." 14.7" 48." Evap Drain (3/4" FPT) Cond Drain (3/4" FPT) - Optional 1.18" 29.23" 36." 32." 32.13" (1." Duct Flange) 1.94" DX - Air Cooled, Self-Contained - Front Evap Discharge Models: VKA-48, 6 & 72 (Single Compressor).38" 4.34" 79." 31." 16." 1." 16." 4.6" 24.9" 14.7" 31.5" 1.69" 48." Evap Drain (3/4" FPT) Cond Drain (3/4" FPT) - Optional 1.18" 29.23" 36." 32." 32.13" (1." Duct Flange) 1.94" 18 Dimensional Data

19 Dimensional Data - DX Air Cooled, Vertical SCAV (6-1 Tons) DX - Air Cooled, Self-Contained - Top Evap Discharge Models: VKA-72, 96 & 12 (Dual Compressors) 18.25" 18.25" 2.88" 59.5" 79." 31." 48.".19" 3.34" 1.18" Drain (1" FPT) 3.16" 17.38" 26.7".25" 6." 32." 56.63" (1." Duct Flange) 1.69" DX - Air Cooled, Self-Contained - Front Evap Discharge Models: VKA-72, 96 & 12 (Dual Compressors) 79." 31." 48." 1.25" 18.75" 2.88" 18.25" 3.34" Drain (1" FPT) 3.16" 17.38" 1.18" 26.7" 59.5".25" 6." 32." 56.63" (1." Duct Flange) 1.69" Dimensional Data 19

20 Dimensional Data - DX Air Cooled, Vertical SCAV (12- Tons) DX - Air Cooled, Self-Contained - Top Evap Discharge Models: VKA-144 & " 21.75" 11.88" 21.75" 31." 3.16" 78.5" 16.81" 83." 52." 82." 3.34" 1.19" Drain (1" FPT) Drain (1" FPT) - Heat Pump Only.38" 32.7" 78.63" (1." Duct Flange) 1.75" 32." 1.69" DX - Air Cooled, Self-Contained - Front Evap Discharge Models: VKA-144 & " 83." 31." 52." 19." 21.75" 11.88" 21.75" 9.81" 3.34" 1.19" Drain (1" FPT) 3.16".38" 32.7" 78.5" 1.75" 82." 78.63" (1." Duct Flange) 32." 1.69" 2 Dimensional Data

21 Dimensional Data - DX Air Cooled, Vertical SCAV (2 Tons) DX - Air Cooled, Self-Contained - Top Evap Discharge (Ships Split w/ Dry-Nitrogen Holding Charge For Rigging Purposes!) Models: VKA " 21.25" 12.38" 21.25" 34." 3.28" 79.75" 17.56" 86." 52." 3.34" 1.19".38".19" Drain (1" FPT) 32.7" 82." 78.63" (1." Duct Flange) 32." 1.69" DX - Air Cooled, Self-Contained - Front Evap Discharge (Ships Split w/ Dry-Nitrogen Holding Charge For Rigging Purposes!) Models: VKA " 21.25" 34." 19." 12.38" 21.25" 3.28" 79.75" 86." 52." 9.56" 3.34" 1.19".38".19" Drain (1" FPT) 32.7" 82." 78.63" (1." Duct Flange) 32." 1.69" Dimensional Data 21

22 Dimensional Data - DX Air Cooled, Vertical SCAV (25 Tons) DX - Air Cooled, Self-Contained - Top Evap Discharge (Ships Split w/ Dry-Nitrogen Holding Charge For Rigging Purposes!) Models: VKA-3 19." 21.25" 9.38" 21.25" 4." 4.1" 82." 21.56" 14." 64." 2.28" 1.18" 17.8" 3." Drain (1" FPT) 41.75" 88." 84.63" (1." Duct Flange) 34." 1.69" DX - Air Cooled, Self-Contained - Front Evap Discharge (Ships Split w/ Dry-Nitrogen Holding Charge For Rigging Purposes!) Models: VKA " 21.25" 4." 19." 9.38" 21.25" 4.1" 82." 14." 64." 14.56" 2.28" 1.18" 17.8" 3." Drain (1" FPT) 41.75" 88." 84.63" (1." Duct Flange) 34." 1.69" 22 Dimensional Data

23 Dimensional Data - Vertical, DX Water/Glycol & Split Air Cooled (4-6T) DX - Water/Glycol Cooled & Split Air Cooled Evaps - Top Evap Discharge Models: VKW, VKG, VKE & VKH-48, 6 & 72 (Single Compressor) 16." 4.34" 16." 1." 31.5" 62." 31.".47" 24.9" 1.69" 31." Drain (3/4" FPT) Water/Glycol, or DX Refrigerant 36." 32." DX - Water/Glycol Cooled & Split Air Cooled Evaps - Front Evap Discharge Models: VKW, VKG, VKE & VKH-48, 6 & 72 (Single Compressor) 4.34".38" 62." 31." 31." 16." 1." 16." 24.9" Drain (3/4" FPT) Water/Glycol, or DX Refrigerant 31.5" 1.69" 36." 32." Dimensional Data 23

24 Dimensional Data - Vertical, DX Water/Glycol & Split Air Cooled (6-1T) DX - Water/Glycol Cooled & Split Air Cooled Evaps - Top Evap Discharge Models: VKW, VKG, VKE & VKH-72, 96 & 12 (Dual Compressors) 18.25" 18.25" 2.88" 59.5" 79." 31.".19" 3.16".25" 48." Drain (1" FPT) Water/Glycol, or DX Refrigerant 6." 32." DX - Water/Glycol Cooled & Split Air Cooled Evaps - Front Evap Discharge Models: VKW, VKG, VKE & VKH-72, 96 & 12 (Dual Compressors) 1.25" 18.25" 59.5" 79." 31." 2.88" 18.25" 3.16".25" 48." Drain (1" FPT) Water/Glycol, or DX Refrigerant 6." 32." 24 Dimensional Data

25 Dimensional Data - Vertical, DX Water/Glycol & Split Air Cooled (12-2T) DX - Water/Glycol Cooled & Split Air Cooled Evaps - Top Evap Discharge Models: VKW, VKG, VKE & VKH-144, 18 & 24 (Dual Compressors) 19." 21.25" 12.38" 21.25" 34." 3.28" 79.75" 17.56" 74." 4.".19" Drain (1" FPT) 82." Water/Glycol, or DX Refrigerant 34." DX - Water/Glycol Cooled & Split Air Cooled Evaps - Front Evap Discharge Models: VKW, VKG, VKE & VKH-144, 18 & 24 (Dual Compressors) 1.44" 74." 34." 19." 21.25" 12.38" 21.25" 9.56" 3.28" 79.75".19" 4." Drain (1" FPT) 82." Water/Glycol, or DX Refrigerant 34." Dimensional Data 25

26 Dimensional Data - Vertical, DX Water/Glycol Cooled & Split Evaps (25 Tons) DX - Water/Glycol Cooled & Split Air Cooled Evaps - Top Evap Discharge Model: VKW, VKG, VKE & VKH-3 (Dual Compressors/Circuits) 19." 21.25" 9.38" 21.25" 4." 4.1" 82." 21.56" 8." 4." 3." Drain (1" FPT) 88." Water/Glycol, or DX Refrigerant 34." DX - Water/Glycol Cooled & Split Air Cooled Evaps - Front Evap Discharge Model: VKW, VKG, VKE & VKH-3 (Dual Compressors/Circuits) 1.44" 8." 4." 19." 21.25" 9.38" 21.25" 14.56" 4.1" 82." 3." 4." Drain (1" FPT) 88." Water/Glycol, or DX Refrigerant 34." 26 Dimensional Data

27 Dimensional Data - Vertical, Free-Cooling Water/Glycol Economizer Box FE - Free-Cooling Water/Glycol Economizer Box - 4 to 25 Tons Models: VKW/VKG-48 thru 3-FE Dimensional Data 27

28 Dimensional Data - Air Side Economizer / Mixing Box Air Side Economizer / Mixing Box Models: VK( )-48 thru 3-( ) Vertical SCAV Systems E B 1.5" 1." " Filter Access C E D A 1.56" AboveAir VK TM Model Size VK( )-48/72 (Single Compressor) VK( )-72/12 (Dual Compressors) Air Side Economizer / Mixing Box - Dimensions A B C D E 3.13" 37.94" 29." 27." 26." 54.13" 37.94" 29." 51." 26." VK( )-144/ " 37.94" 29." 73." 26." VK( ) " 4.94" 32." 73." 29." VK( ) " 46.94" 38." 79." 35." Features: 1. Galvanized Steel Construction 2. Fully Insulated 3. Parallel Blade Dampers with Bronze Bushings 4. Damper Linkage and Hardware 5. Access Doors on Both Sides 6. Economizer Enthalpy Control Systems - field installed 28 Dimensional Data

29 Dimensional Data - Remote Centrifugal Condensing Units 2-Side Access: on Left & Right Sides! W X U DX - Air Cooled, Indoor Horizontal Centrifugal Blower, Remote Condensing Units Models: XCU-48, 72, 96, 12, 144 & 18 V S T P Q B R C Refrigerant E Y AA AB 4 X 9/16" (Hanger Holes) AE AF (Overall to Outside of Hanging Rails) / TOP / BOTTOM DIMENSIONS(inches) XCU-( ) Model No. B C E P Q R S T U V W X Y AA AB AE AF 48, 6, 72 & / / /8 1-5/ /2 6 12, 144 & /4 14-1/ / /8 2-7/ /2 8 DX - Air Cooled Remote Condensing Unit Vertical Floor Mounted, Indoor Centrifugal Blower Models: VCU-48, 6 & 72 (Single Compressor) 4.6" 14.7" 48." Cond Drain (3/4" FPT) - Optional 1.18" 29.23" 36." 32." 32.13" (1." Duct Flange) 1.94" Dimensional Data 29

30 Dimensional Data - Remote Centrifugal Condensing Units (6-2T) DX - Air Cooled Remote Condensing Unit Vertical Floor Mounted, Indoor Centrifugal Blower Models: VCU-72, 96, 12, 144 & 18 (Dual Compressor) 48." 17.38" 1.18" 26.7" 6." 32." Refrigerant 56.63" (1." Duct Flange) DX - Air Cooled Remote Condensing Unit Vertical Floor Mounted, Indoor Centrifugal Blower Models: VCU-144, 18 & 24.38" 1.19" 52." 82." Refrigerant 32.7" 78.63" (1." Duct Flange) 32." 3 Dimensional Data

31 Dimensional Data - Remote Centrifugal Condensing Units (12-25T) DX - Air Cooled Remote Condensing Unit Vertical Floor Mounted, Indoor Centrifugal Blower Models: VCU " 17.8" 64." 88." Refrigerant 41.75" 84.63" (1." Duct Flange) 34." 1.69" Dimensional Data 31

32 Dimensional Data - Outdoor, Remote Air Cooled s Remote Outdoor Propeller Fan Air Cooled s XP1-6 4" Max 33" Lifting Holes 9/16" Dia (4) Control Panel 33 1/8" (Overall) 32" 3 9/16" 9/16" Dia (4) Mounting Holes 3/4" " 31 5/8" XP1/XP2-96,-12 & " 29 3/8" 32" 11/16" 64 5/8" XP2-18, 192, 24, 264, 3, 336, 372 & 432 6" 98.25" Control Panel Return Bend Cover 48." 45." 1.13" 18.25" Lifting Holes 1.5" Dia (Typ.) 96." 42.75" 32 Dimensional Data

33 Blank Page 33

34 VK-Vertical TM Comfort A/C Series 34 VK-Series

35 Model Nomenclature - VK TM Vertical Series Model Nomenclature Packaged Systems & Split s VK W E1 H - FE - A a b - c - d - e f - g - h i a: VK - VertiKul (VK) Comfort Vertical Floor Mounted Series VC - VertiKul-MissionCritical Vertical Floor Mounted Series b: A - DX, Air Cooled C - Chilled Water E - DX, with Compressor G - DX, Glycol Cooled H - DX, Air Handling Unit W - DX, Water Cooled c: 12 = 1 Ton; 18 = 1.5 Tons; 24 = 2. Tons; 3 = 2.5 Tons; 36 = 3. Tons; 42 = 3.5 Tons; 48 = 4. Tons; 6 = 5. Tons; 72 = 6. Tons; 9 = 7.5 Tons; 96 = 8. Tons; 12 = 1. Tons; 144 = 12. Tons; 18 =. Tons; 199 = 16.6 Tons; 216 = 18 Tons; 24 = 2 Tons; 3 = 25 Tons; 36 = 3 Tons d: V / 1 Ph / 6 Hz V / 3 Ph / 6 Hz V / 3 Ph / 6 Hz 5-575V / 3 Ph / 6 Hz 7-277V / 1 Ph / 6 Hz e: - No Heat E1 - Electric Heat 1-Stage E2 - Electric Heat 2-Stages ES - SCR Fired Electric Heat HE - Heat Pump with Auxiliary Electric Heat HG - Hot Gas Reheat HP - Heat Pump w/o Auxiliary Electric Heat HW - Hot Water Heat ES - SCR Fired Electric Heat ST - Steam Heat f: - No Humidifier H - Electrode Canister Humidifier g: - No Economizer AE - Air Side Economizer DC - Dual Cool / Alternate Water Source FE - Water/Glycol Side Free Cooling Economizer h: - None OA - 1% Outside-Air System i: A - Top Air Discharge B - Front Air Discharge C - Top Air Discharge with Plenum Discharge Box a: V - VertiKul (VK) Remote Heat Exchanger X - Exchange TM, Remote Heat Exchanger b: C - DX, Air Cooled, Centrifugal Blower Type G - DX, Glycol Cooled P - DX, Air Cooled, Propeller Fan Type W - DX, Water Cooled c: 1 - Single Circuit, DX 2 - Dual Circuit, DX U - DX Condensing Unit X - DX d: 12 = 1 Ton; 18 = 1.5 Tons; 24 = 2. Tons; 3 = 2.5 Tons; 36 = 3. Tons; 42 = 3.5 Tons; 48 = 4. Tons; 6 = 5. Tons; 72 = 6. Tons; 9 = 7.5 Tons; 96 = 8. Tons; 12 = 1. Tons; 144 = 12. Tons; 18 =. Tons; 199 = 16.6 Tons; 216 = 18 Tons; 24 = 2 Tons; 3 = 25 Tons; 36 = 3 Tons e: V / 1 Ph / 6 Hz V / 3 Ph / 6 Hz V / 3 Ph / 6 Hz 5-575V / 3 Ph / 6 Hz 7-277V / 1 Ph / 6 Hz f: - None HP - Heat Pump Remote Condensing Units V C U a b c - d - e - f - g g: - None OA - 1% Outside-Air System Model Nomenclature 35

36 Innovative HVAC Solutions Ceiling Air Conditioners SpotCool Cool Cool - 2x4 T-Bar Spot-Cooler Comfort & Precision Ceiling Mounted A/C s HK Horizontal ontal ontal - Hi-Static Ducted Same- Face Comfort & Precision Ceiling Mounted A/C s HK-O -O -OA - Horizontal Up to 1% DOAS High- Percentage Outside Air Ceiling Mounted A/C s Floor Air Conditioners 2x4 Spot-Cooler Ceiling Mounted A/C s (1 to 3 Tons) Ducted Same-Face Ceiling Mounted A/C s (1 to 3 Tons) VK Ver ertical tical tical - SCAV, Vertical Floor Mounted Self-Contained & Split Comfort Constant Air Volume and Variable Air Volume (VAV) A/C s & Heat Pumps VK-O -O -OA - Vertical Up to 1% DOAS High- Percentage Outside Air Vertical Floor Mounted A/C s MissionCritical - Precision Vertical Floor Mounted Computer Room A/C s VK Console Console - Vertical Floor Console Mounted Self-Contained & Split A/C s & Heat Pumps Remote Heat t Rejection Comfort - Packaged & Split Vertical Floor Mounted Air Conditioners (1 to 3 Tons) Precision - Vertical Floor Mounted Computer Room Air Conditioners (1 to 3 Tons) VK-Console TM - Up-Flow & Down-Flow Floor Console Mounted Air Conditioners (1 to 5 Tons) FluidCool Cool Cool - Indoor & Outdoor Remote Glycol Drycoolers PumpAll - Single, Dual & Triplex Standard & Variable (VFD) Speed Glycol Pump Packages Remote Air Cooled s, Condensing Units & Glycol Drycoolers (1 to 18 Tons of THR) Single, Dual & Triplex Glycol Pump Packages (1/2 to 5 HP) boveair eair.com Mountville Road Frederick, Maryland 2173, U.S.A. Phone: , Facsimile: sales@aboveair.com Copyright 5/1 Form: AVK-R7-L25 Specifications are subject to change without notice.

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22) Engineering Manual R407c & R410a SC SpotCool 2 x 4 Packaged & Split Ceiling Mounted A/C s (DX & CW Systems) Features & Benefits 1 to 3 Ton Capacities Comfort Applications - General Office Spaces - Conference

More information

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual Engineering Manual From 1 to 3 Tons MC-2x2-2x2 MissionCritical Vertical Floor Mounted A/C s (Single Circuit DX & CW) R407C & R410a Data ta 1 to 3 Tons Compact 24 W x 24 D Footprint Features & Benefits

More information

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual Indoor Cooling Perimeter STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol Self-contained Precision Air Conditioner Utilizing EC Fan Technology

More information

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

Environmental Control

Environmental Control engineering manual Environmental Control mini-might Environmental Ceiling A/C s 1, 1-1/2, 2 and 3 Ton Capacities Perfect for Telecom, ATM & Server Room Applications T-Bar Ceiling Mounted - Ductless Spot

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler

More information

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing

More information

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) with refrigerant Product Description Performance and Electrical Data Dimensional Data Guide

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data Engineering Manual ABOUT STULZ STULZ is a privately owned, global manufacturer of highly efficient temperature and humidity management

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 8 Guide Specification 60 Hz S8-GS-602017.doc 2014 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 8 Guide Specification-60

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Back in the late

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 6 Guide Specification 60 Hz S6-GS-602017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 6 Guide Specification-60

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

CoolSpot Engineering Guide

CoolSpot Engineering Guide Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

RT-OA TM Rooftop Outdoor-Air (DOAS)

RT-OA TM Rooftop Outdoor-Air (DOAS) RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!

More information

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool. Maxi-Kool RTU Roof Top Units 8 30 Ton www.compu-aire.com MK A-3 034 -RTU Maxi-Kool Type Air Cooled - A Chilled Water Cooled - C Glycol Cooled - G Water Cooled - W Nominal Tonnage 8 30 Ton Voltage 2-208

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data â NetworkAIR TM CM Series Precision Air-Conditioning Units 60 Hz Technical Data Contents Available Models................................. 1 Spot-cooled 1 Ducted 1 System Configurations.............................

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

Computer Room Air-Conditioning 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data TM Computer Room Air-Conditioning 60 Hz 10 kw (3 tons) Technical Data Contents Overview.............................................................. 1 Standard Features.......................................................

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Guide Specifications for InRow Direct Expansion

Guide Specifications for InRow Direct Expansion Guide Specifications Guide Specifications for InRow Direct Expansion THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST

More information

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL MODEL DESCRIPTION Table of Contents The LAYTON Advantage... Total Protection----------------------------------------------------------

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Guide Specifications PART 1 GENERAL 1.01 SUMMARY Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Series PS6, Vertical Floor-Mount Units

Series PS6, Vertical Floor-Mount Units Series PS6, Vertical Floor-Mount Units Technical Data 60 Hz sps6em6ea.doc Dec-12 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Table of Contents Table of Contents...

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Data Aire Series Chilled Water 7 through 50 ton

Data Aire Series Chilled Water 7 through 50 ton Data Aire Series Chilled Water 7 through 50 ton ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system

More information

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern Contents Overview.............................................................. 1 Standard Features....................................................... 2 Optional Features.......................................................

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data NetworkAIR Precision Air-Conditioning Units 60 Hz TM AFX Series Technical Data Contents Available Models................................. 1 Downflow 1 Upflow front-return 1 Upflow rear-return 1 Indoor

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

CEILAiR. Engineering Manual. Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems

CEILAiR. Engineering Manual. Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems CEILAiR Engineering Manual Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems Stulz SATS is dedicated to providing innovative solutions for critical temperature

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits 1 Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

SSL & SBS Engineering Guide

SSL & SBS Engineering Guide REDUCED-FOOTPRINT VERTICAL BLOWER COIL UNITS SSL & SBS Engineering Guide SO TOUGH, WE GUARANTEE IT. SSL SBS Table of Contents Features and Benefits... 3 Construction Features... 4 Features and Options...

More information

Direct Gas-Fired Make-Up Air Models DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5

More information

Liebert PDX and PCW Thermal Management Systems

Liebert PDX and PCW Thermal Management Systems Liebert PDX and PCW Thermal Management Systems 3 to 8 Ton (11 to 29 kw) Nominal Capacity, Upflow and Downflow, 60 Hz, Air-, Water-, Glycoland Chilled-water-cooled Models System Design Catalog Technical

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information