Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual

Size: px
Start display at page:

Download "Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual"

Transcription

1 FOR YOUR SFETY If you smell gas: 1. Open windows. 2. O NOT try to light any appliance. 3. O NOT use electrical switches. 4. O NOT use any telephone in your building. 5. Leave the building. 6. Immediately call your local gas supplier after leaving the building. Follow the gas supplier s instructions. 7. If you cannot reach your gas supplier, call the Fire epartment. O NOT store or use petrol or other flammable vapors and liquids in the vicinity of this or any other appliance. lackheat Vacuum ssisted Linear & U-Tube Gas Fired Radiant Heating Systems Installation, Operation & Service Manual WRNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the installation, operation and service manual thoroughly before installing or servicing this equipment. Installation must be done by a contractor qualified in the installation and service of gas-fired heating equipment. Installer Please take the time to read and understand these instructions prior to any installation. Installer must give a copy of this manual to the owner. Owner Keep this manual in a safe place to provide your serviceman with information should it become necessary. Hurll Nu-Way Pty Ltd 14 ristoc Road GLEN WVERLEY VI 3150 Telephone: Fax: UNZ Rev. 2 4/03

2 TLE OF ONTENTS Note: Pages 2,16,17,18,23,32,35,46,54,55 have been deleted as not relevant. SETION 1: Heater Safety...1 SETION 12: Venting...42 SETION 2: Installer Responsibility Flue Installation Low Level User Instructions Flueless Installation (U.K. Only) Halogenated Hydrocarbons Ventilation Requirements National Standards and pplicable odes Outside ombustion ir Supply...43 SETION 3: ritical onsiderations ommon uct Minimum Required learances to ombustibles...3 SETION 13: Gas Piping learance ata - Linear...4 SETION 14: Wiring learance ata -U Tube LKHET Typical External Wiring iagram SETION 4: Specifications... 8 (Linear or U Tube) Material Specifications Heater Specifications Venting Specifications Suspension Specifications ontrols Specifications Linear Heater LKHET Internal Wiring iagram U-Tube Heater...9 SETION 15: Operation urner Specifications Heater Lockout Indication (Optional)...48 SETION 5: Major omponent escriptions Testing...48 SETION 6: General Suspension etails ommisioning Suspension etails System hecks...49 SETION 7: Linear Heater Installation User Instructions Linear Standard Parts List...13 SETION 16: Servicing Instructions nnual Procedure urner Tube Installation omponent Removal oupling and Tube ssembly...19 SETION 17: Troubleshooting Tube lamp Package Installation Troubleshooting Flow hart (Linear and 7.6 Installation U-Tube)...52 SETION 8: U-Tube Heater Installation U-Tube Standard Parts List ritical Hanger Placement urner Tube and Fan Tube Installation U-Tube Support racket ssembly Installation oupling and Tube ssembly Tube Installation U-Tube Installation Installation Manifold Gas Pressure Setting...56 SETION 18: Replacement Parts...57 SETION 10: urner & Fan Installation urner Installation Fan ssembly Linear & U-Tube Fan Installation...34 SETION 11: Optional Heater ccessories Side Extension Installation ecorative Grille Installation Protective Grille Installation Sports Hall Guard Installation Universal Shield Installation Undershield Installation ll rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Roberts-Gordon.

3 TLE OF FIGURES Figure 1: eleted Figure 2: Linear Horizontal Mounts...4 Figure 3: Linear, One Side...4 Figure 4: Linear, Two Side s...4 Figure 5: Linear, 45 Mount...4 Figure 6: Linear, 1 Foot and 2 Foot eco Grille... 5 Figure 7: Linear, Protective Grille...5 Figure 8: Linear, Venting...5 Figure 9: U-Tube, Horizontal Mount... 6 Figure 10: U-Tube, One Side... 6 Figure 11: U-Tube, Two Side s... 6 Figure 12: U-Tube, Full 45 Mount...6 Figure 13: U-Tube, Opposite 45 Tilt... 7 Figure 14: U-Tube, Protective Grille... 7 Figure 15: U-Tube, Venting... 7 Figure 16: LKHET Linear and U-Tube...10 Figure 17: LKHET Linear General ssembly Overview Figure 18: LKHET Linear Layout Overviews...15 Figure 19: eleted Figure 20: eleted Figure 21: Overlap etail Figure 22: LKHET UT ssembly Overview...25 Figure 23: LKHET U-Tube Layout Overviews...26 Figure 24: eleted Figure 25: Typical Manifold Layout (Linear and U-Tube onfiguration) Figure 26: Individual Flue onnection etail...42 Figure 27: Fresh ir Intake Spigot Figure 28: ir Supply with Flue onfigurations...43 Figure 29: Gas onnection with Stainless Steel Flex onnector...44 Figure 30: Sequence of Operation hart...48 Figure 31: urner up Position... 50

4 SETION 1: HETER SFETY SETION 1: HETER SFETY Your Safety is Important to Us! This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and following the warnings in these sections. WRNING Installation, Service and nnual Inspection of heater must be done by a contractor qualified in the installation and service of gas-fired heating equipment. Read this manual carefully before installation, operation, or service of this equipment. Failure to follow these instructions can result in death, injury or property damage. wall tag is supplied with the LKHET heater as a permanent reminder of the safety instructions and the importance of the minimum required clearances to combustibles. copy of the wall tag is illustrated on Page 2, Figure 1. Peel off the backing of the adhesive strips on the rear surface of the tag and position the tag on a wall near the LKHET heater (e.g. thermostat or ROERTS GORON Z Microprocessor ontroller). 2.2 Halogenated Hydrocarbons UTION o not use heater in an area containing corrosive chemicals. void the use of corrosive chemicals to ensure a longer life of the burner, tubing and other parts. Failure to follow these instructions can result in property damage. This heater is designed for heating non-residential indoor spaces. o not install in residential spaces. These instructions, layouts, S5601/G 601,local codes and ordinances, and applicable standards that apply to gas piping, electrical wiring, venting, etc., must be thoroughly understood before proceeding with the installation. SETION 2: INSTLLER RESPONSIILITY To install the heater, as well as the gas and electrical supplies, in accordance with applicable specifications and codes. Roberts-Gordon recommends the installer contact a local building inspector or Fire Marshal for guidance. To use the information given in a layout drawing and in the manual together with the cited codes and regulations to perform the installation. To install the heater in accordance with the learances to ombustibles. To furnish all needed materials not furnished as standard equipment. To plan location of supports. To provide access to burners for servicing on all sides, for burner removal. To provide the owner with a copy of this installation, operation and service manual. To never use heater as support for ladder or other access equipment and never hang or suspend anything from heater. 2.1 Low Level User Instructions In all situations, clearances to combustibles must be maintained. Failure to observe clearances to combustibles can result in death, severe injury or property damage. Signs should be posted in storage areas to specify the maximum stacking height of items placed below heater to maintain required clearances to combustibles. Minimum clearances must be maintained from vehicles parked below the heater. aution should be used when running the system near combustible materials such as wood, paper, rubber, etc. onsideration should be given to partitions, storage racks, hoists, building construction,etc. Roberts-Gordon cannot be responsible for ensuring that all appropriate safety measures are undertaken prior to installation; this is entirely the responsibility of the installer. It is essential that the contractor, the subcontractor, or the owner identifies the presence of combustible materials or halogenated hydrocarbons* anywhere in the premises. * Halogenated Hydrocarbons are a family of chemical compounds characterized by the presence of halogen elements (flourine, chlorine, bromine, etc.). These compounds are frequently used in refrigerants, cleaning agents, solvents, etc. If these compounds enter the air supply of the burner, the lifespan of the heater components will be greatly reduced. n outside air supply must be provided to the burners whenever the presence of these compounds is suspected. Warranty will be invalid if the heater is exposed to halogenated hydrocarbons. 2.3 National Standards and pplicable odes ll ppliances must be installed in accordance with the latest revision of S5601/G 601 and other relevant codes. This refers also to the electric, gas and venting installation. Note: dditional standards for installations in Public Garages, ircraft Hangars, etc. may be applicable. 1

5 SETION 3: RITIL ONSIERTIONS SETION 3: RITIL ONSIERTIONS WRNING Fire Hazard Some objects will catch fire or explode when placed close to heater. Keep all flammable objects, liquids and vapors the minimum required clearances to combustibles away from heater. Failure to follow these instructions can result in death or injury. urn Hazard Keep all persons, especially children, away from heater. o not touch any part of the heater. Heater is very hot. Failure to follow these instructions can result in severe injury. 3.1 Minimum Required learances to ombustibles learances are the required distances that combustible objects must be kept away from the heater to prevent serious fire hazards. ombustibles are materials, which may catch on fire and include common items such as wood, paper, rubber, fabric, etc. Maintain clearances to combustibles at all times for your safety. learances for all heater models are located on Page 4, Figure 2 through Page 7, Figure 15 in this manual. heck the clearances on each burner for the model heater being installed to make sure the product is suitable for your application and the clearances are maintained. Read and follow the safety guidelines below: Keep petrol or other combustible materials including flammable objects, liquids, dust or vapours away from this heater or any other appliance. Maintain clearances from heat sensitive material, equipment and workstations. Maintain clearances from vehicles parked below the heater. Maintain clearances from swinging doors, overhead cranes, vehicle lifts, partitions, storage racks, hoists, etc. In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to the combustibles. Signs must be posted adjacent to the heater thermostat. In the absence of a thermostat, signs must be posted in a conspicuous location. onsult local uilding Inspector, Fire Insurance arrier or other authorities for approval of proposed installation when there is a possibility of exposure to combustible airborne materials or vapours. Hang heater in accordance to the minimum suspension requirements on Page 9, Section 4.6 through Page 9, Section 4.8. If the radiant tubes must pass through the building structure, be sure that adequate sleeving and fire stop is installed to prevent scorching and/or fire hazard. 3

6 LKHET INSTLLTION OPERTION N SERVIE MNUL 3.2 learance ata - NOTE: 1. ll dimensions are from the Tube surface. 2. learances, and can be reduced by 50% after 7 m of tubing downstream from the burner. 3. ll measurements are in Millimeters. FIGURE 2: LINER, HORIZONTL MOUNTS FIGURE 3: LINER, ONE SIE REFLETOR FIGURE 4: LINER, TWO SIE REFLETORS FIGURE 5: LINER, 45 MOUNT

7 SETION 3: RITIL ONSIERTIONS NOTE: 1. ll dimensions are from the Tube surface. 2. learances, and can be reduced by 50% after 7 m of tubing downstream from the burner. 3. ll measurements are in Millimeters. FIGURE 6: LINER, 1 FOOT N 2 FOOT EO GRILLE FIGURE 7: LINER, PROTETIVE GRILLE FIGURE 8: LINER, VENTING Unvented Radiant tubes Vented E F Fan E F

8 LKHET INSTLLTION OPERTION N SERVIE MNUL 3.3 learance ata -U Tube NOTE: 1. ll dimensions are from the Tube surface. 2. learances, and can be reduced by 50% after 7 m of tubing downstream from the burner. 3. ll measurements are in Millimeters.. FIGURE 9: U-TUE, HORIZONTL MOUNT FIGURE 10: U-TUE, ONE SIE REFLETOR FIGURE 11: U-TUE, TWO SIE REFLETORS FIGURE 12: U-TUE, FULL 45 MOUNT

9 SETION 3: RITIL ONSIERTIONS NOTE: 1. ll dimensions are from the Tube surface. 2. learances, and can be reduced by 50% after 7 m of tubing downstream from the burner. 3. ll measurements are in Millimeters. FIGURE 13: U-TUE, OPPOSITE 45 TILT FIGURE 14: U-TUE, PROTETIVE GRILLE FIGURE 15: U-TUE, VENTING Unvented Radiant tubes Vented E F Fan E F

10 LKHET INSTLLTION OPERTION N SERVIE MNUL SETION 4: SPEIFITIONS 4.1 Material Specifications ombustion and Tubes First 3 meters LUMI-THERM steel tubing. Remaining tube 100 mm dia. 16 gauge heat treated aluminised mild steel s NS3 H14 aluminium or R stainless steel (option) 4.2 Heater Specifications Sequence ontroller Fully automatic single try direct spark 100% shut off ignition flame rectification module Electrical Rating: 230V, 50 Hz, single phase, 1 amp onnection: 3 pin moulded plug Gas Supply onnection: Rc1/2 (1/2" SP int) Natural : Nominal - Inlet 1.13kPa Maximum - Inlet 5.0 kpa 4.3 Venting Specifications Fans H-15, 20, 25, : Torin SF H-35, 40, : Torin S H : Magnetek JF1G onsult the manufacturer for availability of alternate fans Flue When fitted, the flue must be 100 mm, or greater in diameter, and must conform to S5601/G 601. The flue must be self supporting. Inlet must be 100 mm diameter. 4.4 Suspension Specifications Galvanised straight link welded chain. Working load of 340 kg (750 lbs) 4.5 ontrols Specifications Time switches, thermostats, etc. can be wired into the electrical supply. External controls supplied as an optional extra. ULPG Gas (Propane or Propane/utane mix): Nominal - Inlet 2.75 kpa Maximum - Inlet 5.00 kpa 8

11 SETION 4: Specifications Linear Heater ST ST ST ST ST ST ST ST Input kw Input MJ Tube Length mm Overall Heater Length - mm Weight kg Heated rea m Minimum Installation Height* m Recommended Installation Height* m U-Tube Heater UT UT UT UT UT UT UT UT Input kw Input MJ Tube Length mm Overall Heater Length - mm Weight kg Heated rea m Minimum Installation Height* m Recommended Installation Height* m *Heights quoted are from ground level to bottom face of firing tube. NOTE:- Factory recommended mounting heights are listed above as a guideline. If infra-red heaters are mounted too low, they may result in heat discomfort. It is generally recommended to observe the recommended mounting heights to optimize comfort conditions. However, certain applications such as spot heating, freeze protection, outdoor patio heating or very high ceilings may result in the heaters being mounted outside of the factory recommended mounting heights. learances to combustibles must always be maintained.

12 LKHET INSTLLTION OPERTION N SERVIE MNUL 4.9 urner Specifications Figure 16: LKHET Linear and U-Tube 171 mm End View Plan View 100 mm Swirler* Fan urner Tube Heat Exchanger Length 317 mm Side View amper 273 mm Plan View Fan 100 mm Heat Exchanger Length urner Tube U-Tube Internal Swirler* Fan Tube amper *Swirler must always be located in Fan Tube urner ir Plate Marking Jet Marking Natural # mm # mm #9 #3 #1 Propane/utane # mm #37 # mm 3.3 mm #29 # Gas onsumption Natural [MJ/hr] ULPG MJ/hr as Natural Gas. pproximate kg/h consumption as below for reference only. [kg/h] [1.07] [1.43] [1.79] [2.15] [2.50] [2.86] [3.22] [3.58] Governor Pressure ULPG ll s 2.60 kpa Natural Gas ll s 0.75 kpa 10

13 SETION 5: MJOR OMPONENT ESRIPTIONS SETION 5: MJOR OMPONENT ESRIPTIONS urner (shown with Tube Gasket) Must be installed with the flame observation window facing down. (luminium or Stainless Steel) lternate overlap as shown on overview. Minimum overlap is 18 cm. urner Tube Supplied in 3m lengths. urner tube is always the first tube after the burner. Tube Heat Treated luminized Tube Supplied in 3m lengths. Fan Tube with Internal Swirler Fan tube is always the last tube on the heater where the fan is attached. Tube and Hanger with Tube lamp Package Position this hanger no more than 20cm away from the burner assembly. Recommended 100mm. Tube and Hanger Suspend system from these hangers. Support Strap, Wire Form & #8 x 3/4 (3.9 x 19mm) oupling ssembly with Lock End ap Punch out center section to accommodate heat exchanger tube. Fan ssembly (Includes Flange) Fan ssembly is attached to the last section of heat exchanger tubing (Fan Tube). Flex Gas Line amper Flange ssembly For use on Multiburner Systems. Tee ssembly Fan Flange ssembly and s Turnbuckle djuster U-Tube ssembly U-Tube Support racket ow Shackle 11

14 LKHET INSTLLTION OPERTION N SERVIE MNUL SETION 6: GENERL SUSPENSION ETILS WRNING Suspension Hazard Hang heater with general purpose welded link steel chain, 4 mm or larger in diameter, with working load of 340 Kg. Failure of the supports can result in death, injury or property damage. Step 6.1 Suspension etails Typical Suspension etails I-eam eam lamp I-eam oncrete eam nchor Hook min. 10 mm Washer Locknut 60 cm minimum* Turnbuckle (not included) 10 mm Rod 30 cm minimum* ow Shackle Washer Wood eam * llows for thermal expansion of system Side View ow Shackle Hanger Hanger 100 mm Max. Front View 45 ngle escription Part Number urner Tube ow Shackle E Tube/ Hanger

15 SETION 7: LINER HETER INSTLLTION SETION 7: LINER HETER INSTLLTION The figures in this section provide a general overview of component placement in a LKHET Linear system. The location of some components such as supports and couplings is crucial for proper installation. ssemble the heater components as shown on Page 14, Figure Linear Standard Parts List For optional reflector configurations for Linear heaters See Page 4, Figure 2 through Page 5, Figure 8. Install appropriate suspension hardware, beam clamps, chain or rod at predetermined locations. djustments of chain length will provide uniform pitch. If any step is unclear, please contact Roberts-Gordon at + 61 [3] [Hurll Nu-Way Pty Ltd] Part No. escription LKHET urner ssembly (Input and Fuel Varies) Fan Package XP Fan Package XP Fan Package XP urner Tube, 100 mm x 3048 mm Tube, 100 mm x 3048 mm S5127W Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler S5134W Fan Tube, 100 mm x 3048 mm with 2134 mm Swirler Standard oupling ssembly oupling Lock , luminium, 2439 mm S5163W, Stainless Steel, 2439 mm (Optional)* End ap, luminium End ap, Stainless (Optional)* Tube and Hanger Tube lamp Package (including Nut, Washer & olt) Wire Form #8 x 3/4 (3.9 x 19mm), (goes with ) Support Strap E ow Shackle U-lip Package (20 Pieces) * PV coating must be removed prior to installation. 13

16 LKHET INSTLLTION OPERTION N SERVIE MNUL Figure 17: LKHET Linear General ssembly Overview End ap urner Tube lamp Package urner Tube Tube and Hanger oupling Support Fan Tube Internal Swirler U-lips Fan ssembly (For Single Heater) amper ssembly (Required for Multiburner) 14

17 SETION 7: LINER HETER INSTLLTION Figure 18: LKHET Linear Layout Overviews -[H55 Not vailable] g b c d e c b LEGEN ST f urner ox g b c d e e c b Tube Tube/ Hanger Support ST ST f oupling ssembly g b c d e e e c b Fan ssembly amper ssembly ST ST ST f g b c d e e e e c b ST ST f g b c d e e e e e b c s - loosened 2 mm (1/16") to allow slippage. H55ST f a = reflector width (not shown) b = end cap to burner/fan c = end cap to hanger d = distance first hanger e = distance typical between hangers f = burner height g = burner length Overlap (approx.) a b c d e f g 700 mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 250 mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 530 mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 330 mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm H mm 365 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 15

18 SETION 7: LINER HETER INSTLLTION Step 7.3 urner Tube Installation NOTE: Tubing requires a downward slope of 13 mm per 6 m away from burner. End View Offset mounting hole must be to the top ow Shackle Hanger urner Tube Weld Seam ottom of Tube 229 cm ± 25cm escription Part Number urner Tube ow Shackle E Tube/ Hanger Step 7.4 oupling and Tube ssembly lose coupling with tab Tab Start Slidebar/oupling Lock onto coupling Slidebar Open 8 cm to 10 cm Wide end oupling losed Insert tubes into coupling en coupling to join tubes Tube Orient coupling so that the impact block is in the 2:00 or 10:00 o clock positions Tube Slidebar escription Part Number oupling Slidebar/oupling Lock Tube oupling Tube 19

19 LKHET INSTLLTION OPERTION N SERVIE MNUL Step oupling and Tube ssembly (ontinued) WRNING en slidebar as shown below. Tubes will fall down if slidebar is incorrect. Failure to follow these instructions can result in death, injury or property damage. rive Slidebar until tight. End of slidebar should be within tolerance listed below. orrect slidebar dimensions ± 5 cm Incorrect slidebar position Repeat Step until all tubes are assembled, See Page 20, Section shown below. Step oupling and Tube ssembly (ontinued) Heat Exchanger Number Overall Tubing Length (m) of Tubes cm ± 25 cm 305 cm Typ ± 25 cm Total Overall Tube Length 20

20 SETION 7: LINER HETER INSTLLTION Step 7.5 Tube lamp Package Installation Tube lamp olt Nut (Torque Nm 120 in lb) Flat Washer escription Part Number Tube lamp olt Flat Washer Nut Step 7.6 Installation Hanger urner Tube escription Part Number Tube/ Hanger urner Tube

21 LKHET INSTLLTION OPERTION N SERVIE MNUL Step Installation (ontinued) End ap Wire Form Sheet Metal U-lips Support Strap Tube escription Part Number Support Package Wire Form Support Strap #8 x 3/4 (3.9 x 19mm) U-lip Package End ap XX U-lip (2 clips per alternate overlaps per sidesee Figure 21) Figure 21: Overlap etail Loose screws loosened 2 mm (1/16") to allow slippage. screws No U-lips screws Install U-lips Loose screws No U-lips Install U-lips Install one reflector support per reflector as needed. 18 cm (7") Minimum 18 cm (7") Minimum 22

22 LKHET INSTLLTION OPERTION N SERVIE MNUL SETION 8: U-TUE HETER INSTLLTION The figures in this section provide a general overview of component placement in a LKHET U-Tube system. The location of some components such as supports and couplings is crucial for proper installation. ssemble the heater components as shown on Page 14, Figure 17. For optional reflector configurations for U-tube heaters See Page 6, Figure 9 through Page 7, Figure 15. Install 8.1 U-Tube Standard Parts List appropriate suspension hardware, beam clamps, chain or rod at predetermined locations. djustments of chain length will provide uniform pitch. If any step is unclear, please contact Roberts-Gordon at +44 (0) or +61 [3] Part No. escription LKHET urner ssembly (Input and Fuel Varies) Fan Package XP Fan Package XP Fan Package XP urner Tube, 100 mm x 3048 mm Tube, 100 mm x 3048 mm Tube, 100 mm x 1524 mm S5127W Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler S5134W Fan Tube, 100 mm x 3048 mm with 2134 mm Swirler U-end Standard oupling ssembly oupling Lock , luminium, 2439 mm S5134W, Stainless Steel, 2439 mm (Optional)* End ap, luminium End ap, Stainless (Optional)* Tube and Hanger Tube lamp Package (including Nut, Washer & olt) Wire Form Support Strap U-end Support racket E ow Shackle U-lip Package (20 Pieces) U-olt M Nut M Lockwasher 6mm #8 x 3/4 (3.9 x 19mm), (goes with ) S7199K amper Flange ssembly (For use on Multiburner Systems) 1 Per Heater *PV coating must be removed prior to installation. 24

23 SETION 8: U-TUE HETER INSTLLTION Figure 22: LKHET UT ssembly Overview Fan ssembly (For Single Heater) amper ssembly (Required for Multiburner) urner Tube lamp Package 20cm Maximum U-Tube Support racket urner Tube oupling Support Internal Swirler Fan Tube U-lips End aps 180 U-Tube 457 mm enter to enter 25

24 LKHET INSTLLTION OPERTION N SERVIE MNUL Figure 23: LKHET U-Tube Layout Overviews g b c d LEGEN urner ox h Tube g b c d f Tube/ Hanger Support oupling ssembly h U-Tube g b c d e h g b c d e f s - loosened 2 mm (1/16") to allow slippage. h a = overall width (not shown) b = end cap to burner/fan c = end cap to hanger d = distance first hanger e = distance typical between hangers f = distance between last full tube hanger and half tube hanger g = burner length h = burner height Overlap (approx.) a b c d e f g 1780 mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 250 mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 580 mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 690 mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm mm 850 mm 50 mm 50 mm 2290 mm 3050 mm 366 mm 291 mm 26

25 SETION 8: U-TUE HETER INSTLLTION Step 8.2 ritical Hanger Placement ow Shackle Spreader ar NOTE: Spreader bar must be used on single suspension point installations. o not hang heater from spreader bar. Threaded ar Suspension hain ow Shackle Washers olt (Torque: 13.5 Nm 129 in lb) Suspension hain Tube and Hanger Optional Hanging onfiguration Tube and Hanger First Tube and Hanger 229 cm ± 25cm escription ow Shackle Tube/ Hanger Spreader ar Part Number E See ssembly rawing Step 8.3 urner Tube and Fan Tube Installation End View Offset mounting hole must be to the top Fan Tube Weld ottom of Tube urner Tube escription urner Tube Fan Tube Part Number S5127W 27

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Blackheat. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. Installation, Operation & Service Manual WARNING

Blackheat. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. Installation, Operation & Service Manual WARNING FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

Gas-Fired, Low Intensity Unitary Heater

Gas-Fired, Low Intensity Unitary Heater FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your uilding. 5. Leave the uilding. 6. Immediately

More information

GordonRay BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual WARNING BH-40 BH-60 BH-80 BH-100 BH-115

GordonRay BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual WARNING BH-40 BH-60 BH-80 BH-100 BH-115 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Low-Intensity, Infrared Heating Systems Submittal: HE Series

Low-Intensity, Infrared Heating Systems Submittal: HE Series Low-Intensity, Infrared Heating Systems Submittal: HE Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT

More information

The Economical, Unitary Infrared Heater Submittal: BH Series

The Economical, Unitary Infrared Heater Submittal: BH Series Blackheat BH The Economical, Unitary Infrared Heater Submittal: BH Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO.

More information

Fuel Conversion Kit Instructions

Fuel Conversion Kit Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters Submittal ata Model M ow Intensity daptive Modulating Infrared Heaters Project Engineer ontractor Model # ate: Submitted by: pproved by: General Specification Fuel Type (heck one) Natural Gas PG Heat Exchanger

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: ADU5, ADU30, ADU35, ADU40, ADU45, ADL5, ADL30, ADL35, ADL40, ADL45 Single Stage Pull Through System (Negative Pressure) 0086

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

System Control. Installation, Operation & Service Manual WARNING. Installer

System Control. Installation, Operation & Service Manual WARNING. Installer System Control Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Vantage EV. Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200

Vantage EV. Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200 Vantage EV Installation, Operation & Service Manual EV-80 EV-110 EV-140 EV-170 EV-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches.

More information

Installation, Operation, Maintenance and Parts Manual

Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual 7DC27 thru 7DC32 Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel

More information

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY GordonRay DF Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO T try to light any appliance. 3. DO T use electrical

More information

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater INSTALLATION / OPERATION / MAINTENANCE Applies to: Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater OWNERS MANUAL WARNING: Improper installation, adjustment, alteration,

More information

Vantage TF. The Twin Fire Unitary Infrared Heater. Installation, Operation & Service Manual TF-160. Quality in Any Language

Vantage TF. The Twin Fire Unitary Infrared Heater. Installation, Operation & Service Manual TF-160. Quality in Any Language FOR YOUR SAFETY If you smell gas: 1.Open windows. 2.DO NOT try to light any appliance. 3.DO NOT use electrical switches. 4.DO NOT use any telephone in your building. 5.Leave the building. 6.Immediately

More information

EP-200 Series Pump. Installation, Operation & Service Manual. Quality in Any Language

EP-200 Series Pump. Installation, Operation & Service Manual. Quality in Any Language EP-200 Series Pump Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the installation,

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

OUH Suspended Oil Unit Heater

OUH Suspended Oil Unit Heater OUH Suspended Oil Unit Heater Industrial & ommercial Heating Systems. www.powrmatic.co.uk HATIN // VNTILATION // AIR ONDITIONIN // O PRODUTS OUH Overview odels Available OUH - reeblowing Oil Unit Heater

More information

BENSON.... Variante3 Fired Unit Heaters...

BENSON.... Variante3 Fired Unit Heaters... NSON Variante3 as ired Unit Heaters 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial

More information

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range Elite Unit Heaters Installation and Commissioning Manual Tubular Unit Heaters Elite Range 40-115 Unit 20 Red Mill Trading Estate, Rigby Street Wednesbury, West Midlands, WS10 0NP Tel: +44(0)121 5067700

More information

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant ... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to

More information

Tube Heater General Manual

Tube Heater General Manual Detroit Radiant Products Co. Tube Heater General Manual To be used in conjunction with Series 2 insert manuals. WARNING Improper installation, adjustment, alteration, service, or maintenance can cause

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual OPTIM RDINT TUBE HETING SYSTEMS Operation, maintenance and servicing manual CONTENTS GENERL INSTRUCTIONS Section Title Page 1. Preparing the Installation 4 2. Checking the Installation rea 5 3. Flue Connection

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you smell gas: 1. Open windows 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5.

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: LRU5, LRU5, LRU0, LRU5, LRU0, LRU5, LRL5, LRL5, LRL0, LRL5, LRL0, LRL5 Single Stage Pull Through System (Negative Pressure)

More information

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER RBDS-1 RBD SERIES CERAMIC HEATERS NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Parabolic Extension: Gas Shut-Off Valve: Reverb

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL ultraschwank Models: UHE & InfraSave Ultimate Models: EIH HIGH RADIANT OUTPUT LOW INTENSITY TUBE TYPE INFRA RED HEATER INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration,

More information

ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL

ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL mwarning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation,

More information

EP-100 Pump. Installation, Operation & Service Manual

EP-100 Pump. Installation, Operation & Service Manual EP-100 Pump Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by litter, dust, feathers or other matter.

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by litter, dust, feathers or other matter. INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT IP55 POULTRY TUBE HEATER Single Stage Pull Through System (Negative Pressure) Models: SRLP (30, 35, 40, 45) IP55 0086 OWNER / INSTALLER: For your

More information

Reflect-O-Ray Oil Fired EDS 3.5

Reflect-O-Ray Oil Fired EDS 3.5 COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you have a Fuel Oil leak: 1. Open windows 2. DO NOT try to light any appliance. 3. DO NOT use electrical equipment. 4. Shut off Fuel Oil supply. 5. Leave

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications Ideal for industrial and commercial applications arge range of heat outputs and burner options Easy installation with a factory fitted bolt-on burner Durable long life stainless steel combustion chamber

More information

DX SERIES TUBE HEATER

DX SERIES TUBE HEATER DX SERIES TUBE HEATER INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open windows. 2. Do not touch electrical switches. 3.

More information

EHL Series Installation, Operation, Maintenance, and Parts Manual

EHL Series Installation, Operation, Maintenance, and Parts Manual Installation, Operation, Maintenance, and Parts Manual 230V-50Hz. [G20 (C14), G25 (C15) and G31 (C16)] Infrared Tube Heater. The EHL Series Infrared Tube Heater is a positive pressure, two-stage radiant

More information

INSTRUCTIONS APPLY TO: Installation Operation Maintenance

INSTRUCTIONS APPLY TO: Installation Operation Maintenance 9-508.3 5H080135 June, 2012 INSTLLTION ND SERVIE MNUL High Intensity Gas Fired Infrared Unit Heaters Model MHR, ontrol odes 47, 48, 97, 98, 27, 67, 38 and 88 INSTRUTIONS PPLY TO: Installation Operation

More information

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity OUH Oil Unit Heater Range ontrolling your working environment heating ventilation integrity 1 Product Overview Benefits Installer riendly ompact Stainless steel combustion chamber/heat exchanger as standard

More information

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual Installation, Operation, Maintenance, and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully

More information

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45 INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45 Single Stage Pull Through System (Negative Pressure)

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater tungsten Smart-heat electric heater BY BROMIC Installation, instruction and service manual SUITABLE FOR electric HEATER MODELS: tungsten 2000w, 3000W, 4000W- AND tungsten 6000w Version 1.5 USA! IMPORTANT

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL TUNGSTEN SMART-HEAT ELECTRIC HEATER BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS: TUNGSTEN 2000W, 3000W, 4000W- AND TUNGSTEN 6000W Version 1.7 USA! IMPORTANT

More information

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater tungsten Smart-heat electric heater BY BROMIC Installation, instruction and service manual SUITABLE FOR electric HEATER MODELS: tungsten 2000w, 3000W, 4000W- AND tungsten 6000w Version 1.4 USA! IMPORTANT

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you smell gas: 1. Open windows 2. DO T try to light any appliance. 3. DO T use electrical switches. 4. DO T use any telephone in your building. 5. Leave

More information

COMMERCIAL Heating and Cooling. Heating, Cooling and Ventilation

COMMERCIAL Heating and Cooling. Heating, Cooling and Ventilation OMMERIL Heating and ooling Heating, ooling and Ventilation World leading climate control solutions Seeley International is ustralia s largest air conditioning manufacturer and a global leader in developing

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail SECTION 7: OPTIONAL HEATER ACCESSORIES Step 7.2.4 Reflector Joint Installation Cut away contour with tin snips. Punch/drill six 3/32" (2 mm) holes. Step 7.2.5 Reflector Joint Detail Install reflector end

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

SERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage

SERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage Installation, Operation and Service Instructions INFRARED HEATER SERIES EvenTube Model ETS Infrared Patio Heater Two-Stage WARNING: FOR OUTDOOR USE ONLY WARNING Improper installation, adjustment, alteration,

More information

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety

PH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety Detroit Radiant Products Co. PH Series Manual Installation, Operation, Maintenance and Parts All persons involved with the installation, operation and maintenance of the heater system must read and understand

More information

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

Heating safely with gas-fired infrared heaters

Heating safely with gas-fired infrared heaters Heating safely with gas-fired infrared heaters Patio Heaters F RO M TH E High Intensity Ceramic Heaters I N F R AR E D H EATE R SAF ET Y CO U N C I L Low Intensity Tube Heaters An AHRI Initiative Construction

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Series RE Infrared Heater

Series RE Infrared Heater Series RE Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,

More information

940ESO Tankless Water Heater

940ESO Tankless Water Heater ngineering Submittal Sheet Overview and ertifications LOW-L U P US Massachusetts Plumbing oard pproved ngineering Specifications Water heater shall be a Model Therm 940 SO for outdoor installation. Plant

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY! DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open Windows. 2. Do not touch electrical switches. 3.

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. MILLIVOLT

More information

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:

More information

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual RETIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Part # 461006 MODEL PVF INDIRECT GS FIRED FURNCES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual Model PVF, Indirect Gas Furnace,

More information

EHL Series Installation, Operation, Maintenance and Parts Manual

EHL Series Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual CE Certified 230V-50Hz. [G20(C5), G25(C6), G31(C7)] Infrared Tube Heater. The EHL Series Infrared Tube Heater is a positive pressure, two-stage radiant

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

Patio Heater Model No. GM and GM

Patio Heater Model No. GM and GM Patio Heater Model No. GM124-003 and GM124-004 FEATURES: The ideal solution for extending the season for outdoor entertaining Maximum output 39.6 MJ/hr Direct ignition Adjustable heat output Safety tip-over

More information

Installation / Assembly

Installation / Assembly Cabinet Cut-out Dimensions...4 Gas Requirements and Connection...5 Leak Testing Procedure....6 LP Gas...7 Natural Gas...9 Installing Side Burner with a Grill...10 Save these instructions! Copyright 2009-2010

More information

COMBUSTION RESEARCH CORPORATION

COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION FOR YOUR SAFTEY If you smell gas:. Open windows 2. DO T try to light any appliance 3. DO T use electrical switches 4. DO T use any telephone in your building 5. Leave the

More information

EP-300 Series. Installation, Operation & Service Manual

EP-300 Series. Installation, Operation & Service Manual EP-300 Series Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation,

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boiler WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions

Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions Series TA/TX/TXR Infrared Heater Installation, Operation and Service Instructions FOR YOUR SAFETY If you smell gas: 1. Open windows 2. Don t touch electrical switches 3. Extinguish any open flame 4. Immediately

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

User s Information Manual Models: 45, ,000 Btu/hr

User s Information Manual Models: 45, ,000 Btu/hr SBR-USER_100161678_2000017137_Rev C User s Information Manual Models: 45,000-260,000 Btu/hr If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

LEGACY AUTHENTICITY CONTENTS

LEGACY AUTHENTICITY CONTENTS I N S T L L T I O N M N U L ONTENTS! EFORE YOU EGIN SFETY & PREUTIONS 2-3 FN PLEMENT 4 MINTENNE 5 IN THE OX 6 TOOLS NEEDED 7 INSTLLTION STEP 1: MOUNTING 8 STEP 2: RETENTION SYSTEM 9 STEP 3: MOTOR SSEMLY

More information

Area Heater AH100 Series

Area Heater AH100 Series Area Heater AH100 Series FEATURES: The ideal solution for extending the season for outdoor entertaining Creates a stylish and attractive ambience Casts an approximate 3 to 5 metre circle of radiant sun-like

More information

INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS Form SQ-IOM-7 6000 SQS/U SYSTEMS GAS-FIRED LOW-INTENSITY INFRARED TUBE HEATERS SERIES: A, B, MB, and C INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS! WARNING! Improper installation, adjustment, alteration,

More information

1 Rev. 1 Row Scoreboard

1 Rev. 1 Row Scoreboard Row Scoreboard imensions must be increased by an amount equal to the additional column length when installation consists additional display components above the scoreboard. (Includes dimensions for welded

More information

Installation Instructions. Warming Drawer

Installation Instructions. Warming Drawer Warming Drawer Models: Installation Instructions ERWD30, EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MRWD27, MRWD30, MWDH27, MWDH30, MWDV27, MWDV30, OWD24, PWD27, PWD30 Part No. 102345 Rev. J All

More information