KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.
|
|
- Julius Goodwin
- 6 years ago
- Views:
Transcription
1 KR Series COMPACT UNIT COOERS Technical Bulletin: KRUC_00_07 Products that provide lasting solutions.
2 Provides Excellent Design Innovations That Enhance Overall Refrigeration Performance The KR Compact Unit Cooler is specially designed with a low sihouette that fits flush to the ceiling utilizing less than inches of headroom. This design gives you more usable storage space for every walk-in application. The KR Series is constructed for high efficiency and ease of maintenance. Standard Features n Swept Wing Fan Blade Design providing minimal noise and improved customer satisfaction. n Non-metallic fan guard. n Front access to refrigeration components for serviceability. n Electrical panel located behind front access hinged aluminum cover. n Standard EC fan motors for //0 and 08-0//0. n Die-formed patterned aluminum cabinet and drain pan with easy-to-clean radius corners. n Pressurized, sealed coils with heavy-walled copper tube and rippled full collar aluminum fins. n Superheat gauge fitting. n Electric defrost models feature efficient coil face heaters, drain pan heaters and defrost controls. Available heater voltages / (H&P Defrost only), 0/, 0/, and 0/ (E Defrost only). n Factory wired fan and defrost controls with convenient terminal strips. n Plug in motor leads. Optional Features and Accessories n These coils can be circuited for fluid or CO application. n PSC motors for //0 and 08-0//0. n Shaded pole motors for 0//0. n Installed TX valve. n Installed liquid solenoid valve. n Wire fan guard. KR SERIES COMPACT UNIT COOERS
3 Ordering Information n Complete model number. n Refrigerant R0A, R07A, R07C, R07F, R07 and R8A/R9A. n Room temperature. n Saturated suction temperature. Specify When Ordering All Models n iquid refrigerant temperature. n Motor and heater voltage. n Optional features. n Optional accessories. Model Key KR E E A K Heater Voltage Unit Type KR = Krack Compact Series A=0//0 B=//0 (For H&P Defrost) H= 0//0 (For E Defrost) K=0//0 Number of Fans Motor Voltage Fin Spacing FPI FPI A=08-0//0 B=//0 H= 0//0 Type of Defrost A = Air Defrost B = Brine E = Electric with Electric Pan G = Pipe Hot Gas with Hot Gas Drain Pan H = Pipe Hot Gas with Electric Drain Pan J = Brine with Electric Defrost (Coil & Pan) K = Pipe Kool Gas with Kool Gas Drain Pan P = Pipe Kool Gas with Electric Drain Pan Motor Type A=Shaded Pole Motors (0V only) B=PSC Motors (V & 0V) E = EC Motors (V & 0V) BTU/h in Hundreds (00) U C U KR SERIES COMPACT UNIT COOERS
4 Air Defrost ow Profile Electric Defrost ow Profile SHIPPING WGT. (BS) MODE KRA-00 KRA-0 KRA-00 KRA-07 KRA-089 KRA-0 KRA- KRA- KRA- KRA-9 KRA-70 KRA- KRA- KRA-0 KRA-0 KRA-08 KRA-09 KRA-7 KRA- KRA-7 KRA-9 KRA- KRA- KRA-8 AIR FOW (CFM) 8 8 8,,,,,,,,,80,,070,070 8,70,70,,,00,0,7, W H CAP. 0 F TD + SST,000,00,000 7,00 8,0 0,00,00,00,00,0 7,000,00,00,000,000,800 9,00,700,00 7,00 9,00,00 9,000,800 DIMENSIONS (IN) IQUID SUCTION HG REFRIGERATION CONNECTIONS # OF HANGERS CHARGE DATA BS OF R0A CAPACITY 0 F TD SHIPPING WGT. (BS) MODE KRE-07 KRE-0 KRE-0 KRE-0 KRE-0 KRE-07 KRE-07 KRE-07 KRE-0 KRE- KRE- KRE- KRE-8 KRE-0 KRE-80 KRE-8 KRE-9 KRE- KRE-0 KRE-0 KRE-70 AIR FOW (CFM) ,70,70,,,,,,,00,80,80,7,,0,0,070, W H DIMENSIONS (IN) -0 SST,700,00,00,00,00 7,00,700 7,00 9,000,00,00,00,800,000 8,000 8,00 9,00,00,000,000 7, SST,000,70,0,080 8,780 9,9 9,00 0,0,0,9 7,00 8,0 9,80,00,00,980, 8,70 9,700,00,0 IQUID SUCTION.... HG REFRIGERATION CONNECTIONS # OF HANGERS CHARGE DATA BS OF R0A
5 Hot Gas Defrost ow Profile MODE KR( )-07 KR( )-0 KR( )-0 KR( )-0 KR( )-0 KR( )-07 KR( )-07 KR( )-07 KR( )-0 KR( )- KR( )- KR( )- KR( )-8 KR( )-0 KR( )-80 KR( )-8 KR( )-9 KR( )- KR( )-0 KR( )-0 KR( )-70 CAPACITY 0 F TD -0 SST,700,00,00,00,00 7,00,700 7,00 9,000,00,00,00,800,000 8,000 8,00 9,00,00,000,000 7, SST,000,70,0,080 8,780 9,9 9,00 0,0,0,9 7,00 8,0 9,80,00,00,980, 8,70 9,700,00,0 AIR FOW (CFM) ,70,70,,,,,,,00,80,80,7,,0,0,070,070 REFRIGERATION CONNECTIONS IQUID SUCTION HG.... # OF HANGERS CHARGE DATA BS OF R-0A DIMENSIONS (IN) SHIPPING WGT. (BS) NOTE: Available Types of Defrost: (K) KGG - Pipe Kool Gas with Kool Gas Pan; (H) HGE - Pipe Hot Gas with Electric Pan; (G) HGG - Pipe Hot Gas with Hot Gas Pan; (P) KGE - Pipe Kool Gas with Electric Pan W H KR Motor Options MODE EC MOTORS STANDARD //0 08-0//0 PSC MOTORS OPTIONA //0 08-0//0 SHADED POE 0//0 FAN FAN FAN FAN FAN FAN NOTE: Information required for complete product Model Key Motor Type, Voltage Code, Heater Voltage Code. Refer to Model Key on page. KR SERIES COMPACT UNIT COOERS
6 Electric Defrost Heater Data MODE FAN 07, 0, 0, 0 FAN 0, 07, 07, 07, 0 FAN,, FAN 8, 0, 80 FAN 8, 9 FAN, 0, 0, 70 0//0 0//0 0// NOTE: Information required for complete product Model Key Motor Type, Voltage Code, Heater Voltage Code. Refer to Model Key on page. Hot Gas Defrost Drain Pan Heater Data MODE FAN 07, 0, 0, 0 FAN 0, 07, 07, 07, 0 FAN,, FAN 8, 0, 80 FAN 8, 9 FAN, 0, 0, 70 //0 0// NOTE: Information required for complete product Model Key Motor Type, Voltage Code, Heater Voltage Code. Refer to Model Key on page. KR SERIES COMPACT UNIT COOERS
7 Dimensional Data C.8 B.8 A.9.7 Electrical Knockouts Back and Top of Unit Slotted Hanger Holes ( x 0.7).9. Air Flow Distributor iquid Connection Suction Connection Removable Front Access Panel Electrical Connection End 0.70 F.P.T. Drain Connection Removable Front Access Panel Refrigerant Connection End D Note: All dimensions in inches. Allow clearance between rear of coil and wall for maximum efficiency and minimum noise level. left side clearance allows for optimum access to electrical connections. UNIT DIMENSIONS SIZE A B C D FAN FAN FAN -.0. FAN FAN FAN Typical System Wiring N H F X B S P 7 8 COI HEATERS COI HEATERS COI HEATERS KR SERIES COMPACT UNIT COOERS
8 Use your QR reader to reference current document version on Krack, a Hussmann Corporation brand 8 Remington Boulevard Bolingbrook, Illinois 00 Ph: Printed in U.S.A. 07 Krack, a Hussmann Corporation brand KRUC_00_07
LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.
H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions. H and GH/G SERIES UNIT COOERS H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height,
More informationMS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.
MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationLow Flow Unit Coolers
BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3
More informationLow Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.
LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationKR Electrical Defrost Unit Coolers (PN E108318_E)
KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN
More informationLow Profile Unit Coolers
CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationLOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,
CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2
More informationLow Profile Unit Coolers
BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...
More informationLevitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)
Levitor II AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications) Technical Bulletin: LEVE_002_103116 Products that provide lasting solutions. Table
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationKR Series Air Defrost Unit Coolers Operating and Installation Manual
KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationLow Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional
Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000
More informationKTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More informationReach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June
LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationBTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature
More informationSM/SV-Space Master Unit Coolers (E R.0)
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008 R.0) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationKTL Two-Way Low Profile Unit Coolers
PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical
More informationSlim Contour Unit Cooler
Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationCompak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)
Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now
More informationUnit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products
PRUCT CATALOG Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products peerlessofamerica.com Welcome to Peerless of America II Peerless of America II Inc. was founded in 1912
More informationHalf Round Evaporators
PRODUCT DATA & INSTALLATION Bullet T30-T-PDI-18 Part # 1047129 PRODUCT SUPPORT web: t-rp.com/truc email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Half Round Evaporators High Temperature Applications
More informationSM/SV Series Space Master Unit Coolers Operating and Installation Manual
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008_G) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationTLV Low Velocity Evaporators
PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature
More informationPage ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018
` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with
More informationBN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide
BN-HGDTB June 2017 Replaces BN-HGDTB, March 2011 Mohave Technical Guide Table of Contents Overview... 2 System Features... 3 Condensing Unit... 4-18 Mohave Hot Gas Defrost Quick Reference... 5 AWEF Ratings...11
More informationPage ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18
` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed
More informationcommercial refrigeration products
commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile
More informationRLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES
` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on
More informationEvaporator Coils. Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils. High Performance Mullion Coils
Evaporator Coils Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils High Performance Mullion Coils The AMCO High Performance Coils AMCO high performance direct expansion evaporator coils are designed
More informationIndustrial Unit Coolers
HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationMHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet
Air Conditioning and Heating SPECIFICATION sheet MHH 13 SEER High Efficiency R410a Split System Heat Pump Standard features: R410a system High efficiency compressor Compact design for easy installation
More informationTEC Coolers. GEA Heat Exchangers. GEA Searle
TEC Coolers GEA Heat Exchangers GEA Searle Quality and Performance making the difference Quality and Performance Eurovent Certification All applicable products are certified under the Eurovent CERTIFYALLprogram,
More informationINSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS SERIES MPA, HPA SERIES MPE, HPE & JPE SERIES MPG, HPG & JPG SERIES MPH, HPH & JPH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION
More informationCondensing Units & Air Handlers
Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright
More informationLK-PL Jan Price List
LK-PL Jan. 2018 Price List Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler
More informationCONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00
BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from
More informationPrice List. BN-PL Oct. 2017
Price BN-PL Oct. 2017 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page
More informationPrice List. BN-PL Jan. 2018
BN-PL Jan. 2018 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page 18
More informationPrice List. CC-PC-PL Jan. 2019
Price List CC-PC-PL Jan. 2019 Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 Low Profile Unit Cooler See page 18 11 14
More informationSPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS
SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS GENERAL Standard walk-in panels to be constructed of 4, 5", 6",8",10" or 12 thick prefabricated panels. PANEL CONSTRUCTION Panels consist of die-formed interior
More informationNext-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. CZ-CFH-0617A Replaces document CZ-CFH-0117A Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of Uni-Paks are Here! ColdZone s
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationRefrigeration Systems by. Cool You Can Count On!
Refrigeration Systems by Cool You Can Count On! www.ref-sys.com Keeping Storage Cool... Refrigeration Systems (RSI) has provided engineered cooling systems to agricultural refrigeration markets and vegetable
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationINSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER SERIES LPA SERIES LPE SERIES LPG SERIES LPH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More informationEngineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle
Engineered efficiency - no matter where or what KMe Coolers Fresh ideas from Searle GEA Searle GEA Searle - Commercial Air Coolers GEA Searle s wide range of commercial unit coolers guarantee the continued
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationAir-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV
LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationLOW PROFILE EVAPORATORS
PS SERIES & PSL SERIES LOW PROFILE EVAPORATORS MEDIUM & LOW TEMPERATURE EVAPORATORS ORIGINAL MANUFACTURED EQUIPMENT PS Series PSL Series HX-404-3 AUS Product Specifications The PS Series Low Line Evaporators
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationToday s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.
Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018
Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationToday s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.
Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More information13 SEER CONDENSING UNITS & AIR HANDLERS
13 SEER CONDENSING UNITS & AIR HANDLERS (GC201305-I) TTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CON TECHNICAL SALES GUIDE-60Hz CAPACITY RANGE:11/2~5
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationSeries PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection
Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment
More informationACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons
ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationC22FC Bulletin # October 1993 Supersedes May 1993
ENGINEERING DATA C22 FC SERIES FULL CASED EVAPORATOR UNITS UP-FLO AIR-CONDITIONING AND HEAT PUMP *13,000 to 63,000 Btuh (3.8 to 18.5 kw) Cooling Capacity *ARI Standard 210/240 Certified Ratings with Matching
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationB24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)
ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400
More informationC22 Bulletin # October 1993 Supersedes May 1993
ENGINEERING DATA H C22 SERIES EVAPORATOR UNITS UP-FLO AIR-CONDITIONING AND HEAT PUMP *12,100 to 73,000 Btuh (3.5 to 21.4 kw) Cooling Capacity *ARI Standard 210/240 Certified Ratings with Matching Outdoor
More informationRheem High Efficiency Modulating EcoNet Enabled Air Handler
Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin K40-THERM-PDI-15 Part # 1069130 PRODUCT SUPPORT web: k-rp.com/ts email: mdcu-lgcu@k-rp.com
More information