1 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () Heating capacity () High Efficiency, Powerful Heating and Cooling

2 7/8/HP Models Lined Up for Coercial & Residential Application New Model Outdoor Unit Dramatically Reduces the Installation Space The installation space for each outdoor unit, including service space, has been reduced to 0.65m 2. Quiet Operation The low operating noise of the newly designed outdoor units (8/HP) marks the industry leading level. Noise level (db) New model (Cooling/Heating) Previous model PUH-7MYF 59/59 65 PUH-8MYF 59/59 65 PUH-MYF 59/60 65 Saltproof Fin Treatment of Outdoor Unit Meets Various Installations Wide Operation Range Newly developed Fan Controller expands the operating ambient temperature. Outdoor Unit New MYF model 1180 Standard Finguard at Air Intake Side Enhances the Product Safety Cooling 550 Operating ambient temp. (Outdoor) Heating Enable to Change Fan Speed(7/8HP) 7 8 External static pressure (Pa) Noise level (db : at Lo-notch) Indoor Unit By introducing new 2-stage Fan Motor in the indoor unit, the fan speed can be changed (Hi/Lo) by the controller for extra comfort. (PEH- Fan speed is preset at high speed.) Affordable External Static Pressure To provide flexibility for duct extension, branching and outlet configuration. Automatic Cooling/Heating Changeover Operation for More Comfort Extra Quiet Operation Along with the innovative noise suppression features found on other Mitsubishi Electric air conditioners, the PEH Series incorporates an improved sirrocco fan to reduce noise. Limitations on Piping Length Indoor H L 50m H m L Outdoor Indoor L 50m H m L Outdoor H

3 Enhanced System Control and Operation Ease Wiring Needs Halved Remarkable SavinginCostandLabor Interactive system management, incorporated using an original technology we call "A-Control," is provided by a single 3-wire power/control cable connecting system components. In addition, a non-polarized, dual core wire employed for the remote control line further facilitates installation work. Full System Diagnosis "A-Control" interactivity between indoor and outdoor units enables the system's self-diagnostic function to be used for examining the entire system; even abnormalities in the outdoor unit will be shown on the remote controller display. Imporvements in display details make more accurate and timely responses for maintenance and repair possible. Remote display alternately shows error code and corresponding model number Power supply wiring to outdoor unit (3-phase) 3-core transmission cable Power supply wiring to indoor unit Remote controller Transmission line (2-core) PEH-7, 8 : Single phase PEH- : 3-phase Flexible Function Setting from Remote Controllers Prepared as Standard Remote Controllers can now be used for the selection and setting of functions such as fan speed, air outlets, etc. which were previously set from the indoor unit base board. Setting changes can also be made very easily at the installation stage. LED CLOCK ERROR CODE OA UNIT ADDRESS NOT AVAILABLE Error code CHECK MODE Self diagnostic target unit address Alternate display Error delection article Building Management System Compatibility "A-Control" technology offers compatibility so that systems of the series can operate as part of the MELANS building air conditioning management system. Once connected by a special adapter (optional), the systems respond to coands given from the MELANS control center. The remote controller can also be used for general system control. M-NET (MELANS) connection Man machine interface (G-50A) Power supply unit PAC-SC50KUA (optional) City Multi Y outdoor unit Local remote controller CLOCK Local remote controller ERROR CODE OA UNIT ADDRESS NOT AVAILABLE CHECK MODE Corresponding model number Set temperature display Room temperature display Adapter PAC-SF48MA-E (optional) Outdoor unit A-cotrol remote controller Operation mode switch Operation lamp Filter sign reset switch Test run switch Check switch Ventilation (Lossnay) mode setting switch (Control linked operation with Lossnay) Wired remote controller < PAR-MAA-E > Efficient Lossnay Ventilation Management The Lossnay ventilation system can be easily connected to and controlled by the interactive "A-Control" system using an adapter. The combined interlocking system offers the ability to remove unclean air from indoor environments while adding 25% savings in operating costs for ventilation compared to conventional systems. Independent control of the Lossnay is also possible. Lossnay operation managed by "A-Control" Use of Two Remote Controllers per Group Thanks to the employment of "A-Control", the remote controller can be installed up to two sets per system. This greatly upgrades operability in residential and coercial application. PZ-53ADF-E LGH-++RS 2 Lossnay connecting cable (PZ-53ADF-E Accessories) Remote controller

4 Specifications Model name Service reference Power supply Indoor Outdoor Total cooling capacity (Gross) BTU/h Sensible cooling capacity (Gross) BTU/h Total cooling capacity (Net) BTU/h Total heating capacity (Net) BTU/h Capacity step % Refrigerant Refrigerant charge kg Refrigerant control Model name Service reference External finish Height Dimension Width Depth Net weight kg Indoor coil Indoor fan Indoor fan motor No. x Motor output CMM Indoor fan airflow (Lo-Hi) CFM L/S External static pressure Aq Pa Sound pressure level db(a) Drain connection Outdoor unit Model name Service reference External finish Color Height Dimension Width Depth Net weight kg Compressor No. x Motor output Outdoor coil Outdoor fan Outdoor fan motor No. x Motor output CMM Outdoor fan airflow CFM L/S Sound pressure level (Cooling/Heating) db(a) Protection devices PEH-7MYB PEH-8MYB PEH-MYB PEH-7MYB-EU PEH-8MYB-EU PEH-MYB-EU ~ 2~2V 50Hz 3N~ 380~415V 50Hz 3N~ 380~415V 50Hz ,0 75,0 98,0 16,0 19,000 24, ,0 63,800 84,600 14,000 16,0 21, ,800 72,000 94,500 15,600 18,0 23, ,600 75,0 93,800 17,0 19,000 24, R Capillary tube PEH-7MYB PEH-8MYB PEH-MYB PEH-7MYB-EU PEH-8MYB-EU PEH-MYB-EU Galvanized steel 428 1,380 1, Cross fin coil Centrifugal (plastic) Direct drive 1-pahse induction motor 3-phase induction motor 1x0.21 1x0.4 1x1.0 48/60 56/ ,695/2,119 1,978/2,472 3, /1, /1,167 1, PUH-7MYF PUH-8MYF PUH-MYF PUH-7MYF-EUS PUH-8MYF-EUS PUH-MYF-EUS Acrylic resin coating MUNSELL 5Y 8/1 1,480 1, (642) 188 (193) *5 221 (226) *5 Hermetic line start 1x5.0 1x5.5 1x7.5 Cross fin coil (Saltproof treatment) Propeller-direct drive 3-phase induction motor 2 x x ,898 6,711 2,783 3,167 59/59 59/60 High pressure switch, Freeze & frost protection fuse, Overcurrent relay (compressor& indoor fan), Internal thermostat (compressor, indoor fan & outdoor fan) Note : 1. Cooling and heating capacities are based on the following conditions; Cooling : Indoor: 27 CDB, 19 CWB, Outdoor: 35 CDB Heating : Indoor: CDB, Outdoor: 7 CDB, 6 CWB Cooling and heating capacities are based on 5m pipe length. 2. Refrigerant charge volumes are factory charged (at 5m piping length). Refrigerant is enclosed in the outdoor unit. 3. The measuring point of the sound pressure level is 1m from the unit surface. 4. Specifications subject to change without notice. 5. Figure in ( ) indicates the dimension with built-in air outlet guide.

5 Outline Dimensions (Unit : ) Model PEH-7, 8MYB holes duct flange Model PEH-MYB holes duct flange 0 0 Control box holes (1 braze) (5/8 braze) sensor Drain : Rc duct flange Controller ( side) Connect wire (PEH-PUH) ( side) Duct earth point (Both duct side) Power supply ( side) holes (For hanging bolt M) Control box holes 131 Refrigerant pipe 28.6 (1 braze) (5/8 braze) sensor 562 Drain : Rc Controller ( side) Connect wire (PEH-PUH) ( side) 5 duct flange Duct earth point (Both duct side) Power supply ( side) holes (For hanging bolt M) Model PUH-7, 8, MYF (1212) (490) (490) (1212) Detail A Detail B 4-15 holes (Hanging) 4-x holes (For mounting anchor bolt M8) 490 (Bolt pitch) A 1212 (Bolt pitch) B Control box (5/8 flare) 7, 8MYF : 25.4(1 flange) MYF : 28.6(1-1/8 flange) 142 Wiring hole

6 Outline Dimensions Model PUH-7, 8, MYF (with optional air outlet guide) (Unit : ) (490) (1212) 4-15 holes (Hanging) 4-x holes (For mounting anchor bolt M8) 490 (Bolt pitch) A B 1212 (Bolt pitch) Detail A (490) (1212) Detail B Control box (5/8 flare) 7, 8MYF : 25.4(1 flange) MYF : 28.6(1-1/8 flange) 142 Wiring hole Accessory pipe (with flange) Main Optional Parts Model PAR-MAA-E PAC-SF48MA PAC-YT32PTA PAC-SE41TS-E PAC-SFRM-E PAC-SE55RA-E Description Standard remote controller M-A transmission converter Program timer Remote sensor Remote operation adapter Remote ON/OFF adapter Guaranteed Operation Range Outdoor temp. ( CDB) Cooling Indoor temp. ( CWB) Range for continuous operation Outdoor temp. ( CWB) Heating Indoor temp. ( CDB) Range for continuous operation Note: As an applicable humidity outside standard for both indoors and outdoors, we recoend use within a range of 35-80% relative humidity. However, it is a condition that there is no be dewy in surfaces of electric parts. HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 0-83, JAPAN P 03 E-1 Prepared in Japan (KMC) New publication, effective July 03 Specifications subject to change without notice.

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7 P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM Job Name: System Reference: : Date: : PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Unobtrusive ceiling-concealed

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7 P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11 M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

Кондиционеры Mitsubishi Heavy

Кондиционеры Mitsubishi Heavy Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL

More information

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

Residential-Use Lossnay

Residential-Use Lossnay HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G09LTCB AS G12LTCB AS G14LTCB OUTDOOR AO G09LTCN AO G12LTCN AO G14LTCN 1. INDOOR UNIT : AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01

More information

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Wall Mounted Split Systems

Wall Mounted Split Systems MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control... R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor

More information

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A12EA7 PUZ-A12NKA7 PUZ-A12NKA7-BS INDOOR

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

6. DUCT TYPE AR 60FUAK, AR 60UUAK

6. DUCT TYPE AR 60FUAK, AR 60UUAK R410A 6. AR 60FUAK, AR 60UUAK ART60UUAK D2D_AR010E/04 2006.05.30 - (06-01) - 6-1. FEATURE MODELS : AR 60FUAK / AO 60FMAYT AR 60UUAK / AO 60UMAYT ART60UUAK / AOT60UMAYT FEATURES Universal design indoor

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7 P-SERIES SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A36EA7 PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR

More information

MITSUBISHI ELECTRIC AIR CONDITIONERS

MITSUBISHI ELECTRIC AIR CONDITIONERS MITSUBISHI ELECTRIC AIR CONDITIONERS OPERATION MANUAL Cooling only Model PRC- 8MYA PRC-10MYA PRC-12MYA PRC-15MYA PRC-20MYA PRC-24MYA PRC-32MYA Service ref. PRC- 8MYA(-03) PRC-10MYA(-03) PRC-12MYA(-03)

More information

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type 11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

DUCTED REVERSE CYCLE AIR CONDITIONING. The Ultimate Comfort Experience... All Year Round.

DUCTED REVERSE CYCLE AIR CONDITIONING. The Ultimate Comfort Experience... All Year Round. DUCTED REVERSE CYCLE AIR CONDITIONING The Ultimate Comfort Experience... All Year Round. Why Ducted Reverse Cycle Air Conditioning? Ducted Reverse Cycle Air Conditioning Whether you live in the tropical

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR G24LMLA OUTDOOR AO G24LALA 1. INDOOR UNIT : DTR_AR063E_01 2013.02.28 - (3) - 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER...

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) 6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1

More information

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7 P-SERIES SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A24EA7 PUY-A24NHA7 PUY-A24NHA7-BS INDOOR

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL . INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8 . INDOOR UNIT CONTENTS.

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire. Multi Split provides comfort in a variety of situations from home to office and store. 00 0 0 08 0 0 ALL TYPE LINEUP & ROOMS MULTI 8 ROOMS MULTI SPECIFICATIONS OF ALL INDOOR UNITS OPTIONAL PARTS FOR SPLIT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G18LFCA AS G24LFCA AS G30LFCA OUTDOOR AO G18LFC AO G24LFL AO G30LFT 1. INDOOR UNIT : AS G18LFCA AS G24LFCA AS G30LFCA DTR_AS052E_01

More information

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Cassette type DESIGN & TECHNICAL MANUAL SINGLE INDOOR AU GLVLB AU G4LVLB AU G8LVLB AU G4LVLA OUTDOOR AO GLALL AO G4LALL AO G8LALL AO G4LALA . INDOOR UNIT : AU GLVLB AU G4LVLB AU G8LVLB

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

1. Safety Precautions Operation Care and cleaning Troubleshooting Specifications... 8

1. Safety Precautions Operation Care and cleaning Troubleshooting Specifications... 8 Contents. Safety Precautions.... Operation... 3 3. Care and cleaning... 5 4. Troubleshooting... 7 5. Specifications... 8. Safety Precautions s Before installing the unit, make sure you read all the Safety

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh

More information

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18. Refrigerant R407C X 1200 - X 1900 Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) 12.3 to 18.0kW 1500 to 3800 m 3 /h X 1200 / X 1900 1 Product Codes Models AR

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

Ducted Air Conditioning

Ducted Air Conditioning Ducted Air Conditioning Why Choose Mitsubishi Electric? Whether it is consistent heating and cooling for the home or office, Mitsubishi Electric offers you state-of-the-art technology that is quiet, simple

More information

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a

More information

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions 1509876HC8301 Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions Energy Recovery Ventilator MODELS: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E Operating Instructions (For the user)

More information