1 SOS Multi-Horsepower Outdoor Condenser Fan Motor Slim Stack # Wizard fits many 1/3 HP installations that will not accept competitor s motors. Wide range motor that will run at any fan load from 1/6 to 1/3 HP at a nominal 1075 RPM. RPM HP Voltage Amps A B C /3, 1/4, 1/5, 1/6 208/ / /3, 1/4, 1/5, 1/6 208/ /2 Reversible rotation 5 1/2 Diameter Vertical Condenser Fan Motors Designed for either vertical shaft up or shaft down applications. Shell and end shields are enclosed for weather protection. Suitable for air conditioning or heat pump applications. Revesibile rotation, 208/230 Volts, single speed, 1075 RPM Sleeve Bearing Dimensions HP Amps Cap Req. A B C / / / / / / / / / / / / / / /2 Ball Bearing: / / / / / / / / / / / /2

2 5 1/2 Diameter PSC Furnace Blower Motor Designed for use as direct drive furnace blower motors. All are electrically reversibile and include 2 ¼ resilient rings for base mounting. Bases are sold separately. Three speed, 1075 RPM, reversibile rotation Dimensions HP Volt. Amps Cap.Req. A B C / / / /4 208/ / / / / /3 208/ / / / / / /2 208/ / / / / /4 208/ / /2 5 1/2 Diameter Split Phase Belted Fan and Blower Motors All angle sleeve or ball bearing Resilient base mounted 1/2 Shaft diameter 5/8 adapter with key 1725 RPM Reversible Rotation Dimensions HP Volts Fla A B C / / * 1/ * 3/ *Ball Bearing Rotation viewed end opposite shaft

3 Unit Bearing Motors 35 and 50 Watt Output RPM Speeds Volts Amps Rotation Shaft Dia W CWLE THD W CWLE THD W CWLE THD W CWLE 3 8 x , 6, 9, and 16 Watt 3 1/2 Inch diameter 51 frame unit bearing cast iron motors. Used on refrigerators, freezers, food and beverage coolers, vending machines, display cases and many other fan duty applications RPM - - 1/4-20 threaded shafts Cast Iron Single Mount GE # Watts Rot. Volts Amps 5KSP51 OSE CW AL511 4 CW AL513 4 CCW AL512 4 CW AL514 4 CCW CL501 6 CW CL502 6 CCW ECL551 9 CW ECL553 9 CCW ECL552 9 CW ECL554 9 CCW GL581T 16 CW GL583T 16 CCW GL582T 16 CW GL584T 16 CCW Double Mount: UB05CWL2F 5 CW 115 UB09CWLA2F 9 CW 115 Aluminum Single Mount UB06CWLA 6 CW 115 UB09CWLA 9 CW 115

4 A.O. SMITH 3.3 Diam. General Purpose Motors replace many O.E.M s For use in evaporator fans, exhaust fans, Space heaters, air over fan duty. Shaded pole, single speed Open ventilation Rotation viewed by looking at shaft end # 9721 HP Volts RPM Amps Rot. Shaft 9721 * 1/12 208/ CCW 5/16 x 2 5/8 * Includes 4M/370V Capacitor HP Volts RPM Amps Rot. Shaft 30 1/ CW 5/16 x 2 1/4 31 1/ CCW 5/16 x 2 1/ / CCW 5/16 x 2 1/ / CW 5/16 x 2 1/4 26 1/ CW 5/16 x 2 1/4 Same as above - totally enclosed 692 1/ CW 1/4 x 2 1/ / CCW 1/4 x 2 1/4 Refrigeration Unit Heaters Space Heaters 5 Diameter Motors Mechanically Reversible HP RPM Speeds Volts Amps Length Rotation Dim / / x CWSE / / x CCWSE / / x CWSE / / x CWSE / / x CWSE / / x CCWSE 4-3 4

5 One-On-One Direct Replacement Motors Rotation viewed from back of motor Speeds Dimensions Diam. Volt HP RPM Rot. Amps A B C / /5 1075/1 CW /2 Replaces Copeland # and /2" 230 1/3 825/1 CW /2 Replaces Copeland # and / /4 1625/1 CW /2 Replaces Copeland # and A 5 ½ 208/230 ½ 1625/1 CW ½ Replaces Fasco D / /3 1625/1 CW /2 Replaces Hussman - Fasco #D801, Hill # PP3955B Includes bracket / /6 1550/1 CW /2 Replaces Hussman # S3057, Fasco D807, Universal # / /2 1725/1 CW /2 Replaces Hussman #Emerson 644, Gk55hxctp-9963, Includes capacitor

6 Bohn Evaporator Motors (Rotation viewed shaft end) HP Volt Amps Rot RPM Shaft 5008SS 1/ CWSE / TS 1/ CWSE / LS 1/ CWSE / MS 1/ CWSE / SS 1/ CWSE / TS 1/ CWSE / SS 1/ CWSE /4 5021SS 1/ CWSE 3000 (Box type) 5008SS 5008TS 5034LS 5034MS 5036 SS 5036TS 5025SS Tecumseh O.E.M. Motors HP Volt Amps Rot RPM Shaft / CW /16 Replaces # 810G037A48, 810E026A74 (Rotation opposite shaft end) TFM 372 1/ CWLE 1300/1500 5/16 Replaces # 810E037A69, # 810E037A84 TFM 502 1/ CCWLE 1300/1500 5/16 Replaces # 810E050A85 TFM / CWLE 1300/1625 5/16 Replaces # 810E186A TFM372 TFM1862 TFM502

7 TECUMSEH Evaporative Condensate Unit Fan Assembly Replacement Kit : Rat Number Description XFBGS-109 Fan Motor, Blade, Guard & Shroud Assay 9W 115V Replacement motors only: 6W115 6W230 6W 115V 9W 230V DAYTON Square Motor used in many HVACR applications 4WCT45 A/C Axial fan motor and blade - SQUARE Utility Motor Kits Versatile replacement for all C frame motors Used on reach-in, and walk-in evaporators, exhaust fans, Ventilator fans, range hoods, electric unit heaters, Forced air heaters. Volts RPM Rotation Shaft (Reversible) SM CW/CCW 3/16 X 1 1/4 SM / CW/CCW 3/16 X 2 3/8 Includes hardware kit, fan blades, mounting bracket, hub adapter, 1/4 and 5/16 shaft adapter. Motor Rotation as viewed facing shaft.

8 Although we stock a large number of standard and O.E.M. motors, quite often a motor cannot be identified through the original equipment manufacturer s model number. By following a procedure that answers specific questions about the old motor, a correct replacement can be selected. Provide as much information as possible; we will comb all of our resources to find a replacement. 1. If possible, bring the old motor into the store. 2. What is the application? 3. What type of motor is it? 4. What ventilation does it have? 5. How is it mounted? 6. What is the direction of rotation? 7. How many speeds does it have? 8. What is the horsepower, RPM and voltage? 9. What is the shaft length and diameter? 10. Does the motor have any special features? 11. What type of bearings does it have? 12. What is the O.E.M. part number on it?

9 Tecumseh O.E.M. Fan Blades Blades 5/16 Hub, CW, 14 dia. Bohn O.E. M. Blades 5132C 10 CW 40 pitch 5/16 Shaft 5 Blade Blade Bore 1/4 CW 7 3/4 dia Blades Bore 1/4 CW 9 dia. ( 5 Blade 5/16 Shaft ) 5140C 12 CW 23 pitch 5110E 12 CCW 23⁰ pitch Blade Bore 1/4 CW 10.8 dia. 5 Wing Hubless Fan Blades a Aluminum Blade Bore 5/16 CW, 14 dia. Plastic Blades: Rot. Blade Dia. Pitch CW CCW CW CCW CW CCW CW 10 30⁰ CCW 10 30⁰ 5 Wing FB402 4 CW 3/16 Shaft FB /16 CCW 31/6 Shaft FB502 5 CW 1/4 Shaft FB501 5 CW 3/16 Shaft FB504 5 CCW 3/16 Shaft

10 3 and 4 Wing Heavy Duty Condenser Blades: Typical applications: Air Cooled Condensers, Residential Air Conditioners, Heat pumps, Roof Top A/C s, Power Roof Ventilators, Fan coil Units. Dia. Pitch Rotation Dia. Pitch Rotation 4 Blades: 3 Blades: CW CW CCW CCW CW CW CCW CCW CW CW CCW CCW CW CW CCW CCW CW CCW CW CCW CW UNIVERSAL HEX HUBS CCW CW / CCW / CCW / CCW / CW / CCW /4" CW CCW CW CCW CW CCW FAN PULLER CW CCW REMOVES FAN BLADES AND CW BLOWER WHEELS THAT ARE CCW FROZEN TO THE SHAFT/ CW CW CCW FBP 100

for Refrigeration Applications

for Refrigeration Applications A Regal Brand for Refrigeration Applications Direct Drop-In Replacement Supermarket Case Evaporator Fan Motor Advanced ECM Design Cast Iron 15 Leads Lyall Plug UL/CUL approved E128044 Up to 65% Efficiency

More information

Replacement Fractional Horsepower Motors

Replacement Fractional Horsepower Motors TOTALINE UNIVERSAL AFTERMARKET MOTORS Replacement Fractional Horsepower Motors for the HVAC/R Industry TRUST TOTALINE ON YOUR TRUCK DIRECT DRIVE BLOWER MOTORS Totaline Direct Drive Blower Motors are three

More information

SELECTING A MOTOR MOTORS

SELECTING A MOTOR MOTORS SELECTING A MOTOR Although selecting a replacement motor isn t a science, there are rules, and rules of thumb, that will provide you with a suitable replacement motor. It should be mentioned that the best

More information

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631) Digi-Motor Azure Direct Drive Motor Azure Condenser Fan Motor Azure 3.3" Commercial Refrigeration Evaporator Fan Motor ECM for Commercial Refrigeration Fan/Motor System Made in USA Case Motor IP55 Rated

More information

Fan Blades & Accessories

Fan Blades & Accessories D46 WHEN SHOULD YOU REPLACE A PROPELLER? HERE ARE A COUPLE OCCASIONS: Propeller balance is very sensitive. All Lau props are balanced AFTER the label has been applied to the blade. Balance is subject to

More information

Replacement Fractional Horsepower Motors for the HVAC/R Industry

Replacement Fractional Horsepower Motors for the HVAC/R Industry Motors Replacement Fractional Horsepower Motors for the HVAC/R Industry MOTORS Table of Contents Motors Page No. HVAC Motors: Azure Digi-Motor, Direct Drive...M-3 Azure Digi-Motor, Condenser Fan...M-3

More information

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX.

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX. OEM: Admiral-Emerson Single Phase, PSC Replaces Fasco No. D853 3 lug mounting 1/3 1300/3 230 48Y BALL X204 48A17O126 $162 F1 2.5 10 4 3/8 2 1/8 x 1/2 x 4 7/8 16 OEM: Amana/Rheem/Luxaire/Rooftop Package

More information

ACME MIAMI. Product Catalog

ACME MIAMI.   Product Catalog ACME www.acmemiami.com Product Catalog Contents Defrost Heaters... 1 Flexible Bend-to-Fit for Coils & Condensate Pans 700 Series and Ball Bearing Motor Kits... 2 & 3 Commercial Refrigeration Motor Kits

More information

A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING

A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING KRYO FORTRESS RESS MOTORS/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 AND IP67 RATING BUILT TO PROTECT The KRYO FORTRESS motor is an energy-efficient, unit bearing style ECM

More information

KRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING

KRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING KRYO FORTRESS MOTOR/FAN PACKS A HIGH- ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING motor BUILT TO PROTECT The KRYO FORTRESS motor is an energy-efficient, unit bearing style ECM motor built to withstand

More information

INTERLINK PARTS RECOMMENDED STOCKING LIST 2018

INTERLINK PARTS RECOMMENDED STOCKING LIST 2018 INTERLINK PARTS RECOMMENDED STOCKING LIST 2018 BLADES 2291030 BLADE 10 DIA 31 DEG 5/16 CCW HF 5B 2291031 BLADE 10 DIA 31 DEG 5/16 CW HB 2292625 BLADE 26 DIA 28 DEG 1/2B CW HF 4BL 2293030 FAN 30 DIA 30

More information

The Replacement Motor & Fan Specialists

The Replacement Motor & Fan Specialists The Replacement Motor & Fan Specialists Residential Commercial Electric Motors Fans & Blowers Hydronic Pumps Accessories www.soperssupply.com Industrial Soper s Supply Ltd. Proud Distributor of the Following

More information

NM1850 SERVICE PARTS

NM1850 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor... This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source! Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also

More information

Gas Furnace Limits and Plenum Thermostats

Gas Furnace Limits and Plenum Thermostats New! Gas Furnace Limits and Plenum Thermostats Direct OEM Replacements Economical Use 36T Electrical Ratings Carrier Goodman Lennox Rheem Trane York BDP Janitrol Air-Ease Corsair GE Borg-Warner Bryant

More information

FM1500 SERVICE PARTS

FM1500 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing the parts to be certain that this is the correct parts list. FM00 SERVICE PARTS

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232,

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232, PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F0267 115,137,215, 232, 237 43.15 Bearing, Motor,Frt.Coupling F0427 113,117,127,217

More information

High Efficiency Motors

High Efficiency Motors High Efficiency Motors HVAC Commercial Refrigeration REV 2/11/14 ECM Table for of HVAC Contents SERIES 950 Table of Contents ECM for HVAC Accessories for Azure Digi-Motor...4 Azure Digi-Motor...3 ECM Speed

More information

Marley Ultra Quiet Fan

Marley Ultra Quiet Fan USER MANUAL Marley Ultra Quiet Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2012-1165 ISSUED 8/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE USER MANUAL ultra quiet fan INSTALLATION OPERATION MAINTENANCE Z0414808 rev A ISSUED 02/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and handling Safety Warning

More information

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016 Shelleybasic Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 0 Contents Condensing Unit Assembly, / HP, Ra... Condensing Unit Assembly, / HP, R0a... Condensing

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

Dean Pump High Temperature Chemical Process Inline Pumps

Dean Pump High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump High Temperature Chemical Process Inline Pumps Series DL Dean Pump Series DL High Temperature Chemical Process Inline Pumps Capacities to 600 GPM (182 m 3 /hr) Heads to 0 feet

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS USER MANUAL Marley X7 Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2010-1234A ISSUED 3/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. Fan Components 1

More information

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing

More information

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Smart Comfort Solutions HIGH VELOCITY DRUM FANS Smart Comfort Solutions HIGH VELOCITY DRUM FANS Direct Drive Drum Fans Direct Drive drum fans are great for heavy duty air circulation in light duty commercial applications where an economical solution

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................

More information

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE UEE Electrotechnology Training ackage UEEEEJ07A Air conditioning and refrigeration systems, major components and associated Learner Workbook Version Training and Education Support Industry Skills Unit

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

361 RFD DOORS 2 \ Item # Part # - - Description. Description. Item # Part #

361 RFD DOORS 2 \ Item # Part # - - Description. Description. Item # Part # 361 RFD DOORS 2 \ I -24 4-5- -6 6- Item # Part # - - Description Item # Part # - - Description 0-17052-0 2-2126-01 6-20-004-0 3-21-013-0 3-42-026-0 6-20-041-0 2-2182-11 3-60-022-2 2-8066-01 11 6-20-039-0

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I Page 90. Date January, 004 Supersedes //95 B4JRMBH Packing Construction 3 9 3 8 Volute Impeller B/M No. Rotation Case Impeller Diameter B3 CW H03843 L059 3.50 B33 CCW H03848 L0594 3.50 8 00 095 3 See Supplement

More information

Centrifugal Blower. Backward/Aerofoil Curved.

Centrifugal Blower. Backward/Aerofoil Curved. Centrifugal Blower Backward/Aerofoil Curved www.humidin.com Centrifugal Blower Backward/Aerofoil Curved When Quality Speaks For Itself As a leading manufacturer of Centrifugal Blower Backward/Aerofoil

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Evaluation Report 509

Evaluation Report 509 Printed: June 1987 Tested at: Lethbridge ISSN 0383-3445 Group 5i Evaluation Report 509 Prairie Pride TR-36 Series Ventilation Fans A Co-operative Program Between ALBERTA FARM MACHINERY RESEARCH CENTRE

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Smart Comfort Solutions HIGH VELOCITY DRUM FANS Smart Comfort Solutions HIGH VELOCITY DRUM FANS Direct Drive Drum Fans Direct Drive drum fans are great for heavy duty air circulation in light duty commercial applications where an economical solution

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Chapter 39 Cooling System Fundamentals Test

Chapter 39 Cooling System Fundamentals Test TERRY FOX AUTOMOTIVE Chapter 39 Cooling System Fundamentals Test When you are done this test guess what you think you will receive for a mark below. If you are within 2 of your actual score you will receive

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS *s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT

More information

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material 1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

Braemar Wall Furnace D-12 Fan FB Gas Glo Drum Fan FB Gas Glo Axial Fan AX Vulcan 20 Series Fan FD

Braemar Wall Furnace D-12 Fan FB Gas Glo Drum Fan FB Gas Glo Axial Fan AX Vulcan 20 Series Fan FD GAS AND FUEL FANS All Prices are GST Inclusive Braemar Wall Furnace D-12 Fan FB-96-316-01 Gas Glo Drum Fan FB-126-374-01 Gas Glo Axial Fan AX-150-375-01 Vulcan 20 Series Fan FD-96-3 72-01 Vulcan Burwood

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6 This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing parts to be sure that this is the correct parts list. There have been several

More information

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER: MK-00 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS CAUTION: Read all safety and operating instructions before using this equipment Enter the Serial Number of your new saw in the space

More information

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers RED DOT UNITS R-1630 Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL The R-1630 combines powerful heating and cooling with the compact profile you need for tight spaces. It easily

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM The GH Series The GH is Carver s horizontal, end suction pump series for handling water, oils, and chemicals in marine, process, and general

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL www.mkdiamond.com OWNER S MANUAL & PARTS MANUAL Revision 106 03.2019 Manual Part No. 166894 Caution: Read all safety and operating instructions before using this equipment. This manual MUST accompany the

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

Self-Contained Reverse Cycle Air Conditioners

Self-Contained Reverse Cycle Air Conditioners Self-Contained Reverse Cycle Air Conditioners Models MA 07-10-12-16-24 General Description Marvair's water source self-contained reverse cycle air conditioners are designed for use in either fresh or salt

More information

FAN MOTOR CHINA ELECTRIC MOTOR ASSOCIATION GUANGDONG M&C ELECTRIC POWER CO.,LTD

FAN MOTOR CHINA ELECTRIC MOTOR ASSOCIATION GUANGDONG M&C ELECTRIC POWER CO.,LTD FAN MOTOR CHINA ELECTRIC MOTOR ASSOCIATION GUANGDONG M&C ELECTRIC POWER CO.,LTD Shape Pole Motor Capacitor Running Motor 1 58 SERIES SHADED POLE MOTORS Main Features 1. Rated voltage and frequency can

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS

THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS THE PREMIUM QUALITY LINE FROM HEAVY DUTY, INDUSTRIAL AND COMMERCIAL AIR CIRCULATORS Visit our website at: www.marleymep.com AUTOMOTIVE AIR CIRCULATOR Safety yellow motor, guards, and mounts Hinged guards

More information

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet 3020/3120 Series Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet A Crane Co. Company DEMING PUMPS Introducting Deming 3020/3120 Series End-Suction

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

June 8, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306)

June 8, Davies Supply Calgary (800) Lethbridge (877) Saskatoon (877) (403) (403) (306) June 8, 2018 Terms & Conditions Prices only available to customers with a current Davies Account that is in good standing Limited quantities, availability may vary by branch Quantity listed may not be

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

CME1056 Service Parts. Table of Contents

CME1056 Service Parts. Table of Contents This is the parts list for the CME0 ice machine. The CME0 was manufactured in A, D, E and F series, as well as single phase 0 Hz, single phase 0 Hz, and three phase. The E series change was to side panels

More information

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

burner head porting crescents Used on 30" ranges burner head porting crescents 3-1/8" 3-5 8" Used on 30" ranges burner head porting crescents

burner head porting crescents Used on 30 ranges burner head porting crescents 3-1/8 3-5 8 Used on 30 ranges burner head porting crescents electrolux athens - frigidaire - gibson - kelvinator - tappan Gas range parts 316039002 Burner, Front 3-1/8" 7-5/8" burner head porting crescents 13-3/4" 3-5/8" 316039003 Burner, Rear Used on 30" ranges

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

40 RM/RMS Packaged Air-Handling Units

40 RM/RMS Packaged Air-Handling Units ConcepcionCarrier Air conditioning Company Philippines 40 RM/RMS 008034 Packaged AirHandling Units INSTALLATION MANUAL, STARTUP & SERVICE INSTRUCTIONS Contents Page Page Safety Considerations 1 40RM Physical

More information

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION INDEX Introduction....................................... 3 Checking Product Received.......................... 3 Standard Unit Features.............................. 3 Unit Dimensions...................................

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service Vortex End Suction SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service WIDE RANGE OF APPLICATIONS: Food Processing Solids Waste Water Treatment Pollution Control Slurries Industrial Process

More information

AFE400 SERVICE PARTS

AFE400 SERVICE PARTS This is the parts list for the AFE00. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured

More information

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998 Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5 Section V COOLING SYSTEM CONTENTS Fluid Fan Drive (Silent Flite) 3 Water Pump 4 Radiator 5 Water Temperature Gauge 6 Thermostat 7 Radiator Pressure Cap 7 Service Diagnosis 7 DATA AND SPECIFICATIONS COOLING

More information

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT WRV-S WRV-T Models: WLV-S WLV-T Contents Description Page Cabinet Components Right (Extreme Duty Door) Exploded View...

More information

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450 1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside

More information

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost. LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of

More information

2016 INDUSTRIAL FAN CATALOG

2016 INDUSTRIAL FAN CATALOG 2016 INDUSTRIAL FAN CATALOG airkinglimited.com TABLE OF CONTENTS Introduction 2 Industrial Grade Quiet Floor Fans 3 Industrial Grade Quiet Pedestal Fans 4 Industrial Grade Quiet Wall Mount Fans 5 1/3 HP

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information