DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Size: px
Start display at page:

Download "DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower"

Transcription

1 PRODUCT SPECIFICATIONS GAS FURNACES SL80DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 060 November 07 Supersedes August 05 MODEL NUMBER IDENTIFICATION SL 80 DF 070 X V 36 A AFUE - 80% Input - 66,000 to 0,000 Btuh Nominal Add-on - to 5 Tons Unit Type SL = Dave Lennox Signature Collection Stages = Two-Stage AFUE 80 = 80% Configuration DF = Downflow Nominal Gas Heat Input 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh Cabinet Width A = 4-/ in. B = 7-/ in. C = in. Nominal Add-On Capacity 36 = -3 tons 48 = 3-4 tons 60 = tons Blower V = Variable Blower Motor Low NO x X = Units meet California Nitrogen Oxides Standard (40ng/J) Downflow indoor coils with the same letter designation will physically match the furnace supply air opening.

2 FEATURES CONTENTS H K Blower Data... 3 Dimensions - Accessories... Dimensions - Unit... 0 I Features... J Gas Heat Accessories... 9 Altitude Derate... 9 Installation Clearances... 9 L Model Number Identification... Optional Accessories... 8 Specifications... 8 B F G M C E D NOTE - SL80DFV FURNACES ARE NOT AVAILABLE IN CANADA! WARRANTY Duralok Aluminized Steel Heat Exchanger - Limited twenty year warranty in residential applications, ten years in non-residential applications. All other covered components - Limited ten year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are certified by AHRI. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. ISO 900 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. SL80DFV / Page APPLICATIONS Input capacities of 66,000, 88,000 and 0,000 Btuh. Energy efficiency (AFUE) of 80%. Compact cabinet for utility room, alcove or closet or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. NOTE - FURNACES CANNOT BE TWINNED! Zoning Applications The SL80DFV furnace can be used with the Lennox iharmony Zoning System with the icomfort Communicating Thermostat. The iharmony Zoning System provides direct feedback to the furnace, controlling both airflow and heat output to match the comfort requirements for up to four zones.

3 B C D E F FEATURES HEATING SYSTEM SilentComfort Technology Patent pending burner sound enclosure and extra cabinet insulation reduces operating sound levels. Lennox Duralok Heat Exchanger Assembly Heavy gauge aluminized steel heat exchanger. Crimped seam clamshell type design. Designed for normal expansion and contraction. Minimum resistance to air flow. Heat exchanger has been laboratory life cycle tested in excess of industry standards. Compact size of heat exchanger permits low overall design of furnace cabinet. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. 0 volt. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Two-Stage Gas Control Valve 4 volt redundant combination two-stage gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Two- Combustion Air Inducer Heavy duty, permanent split capacitor (PSC) two-speed blower prepurges heat exchanger and safely vents flue products. Dual pressure switches (low fire/high fire) prove blower operation before allowing gas valve to open. Operates only during heating cycle. G H I Flame Rollout Switch Manual reset switch is factory installed on burner box. Switch provides protection from abnormal operating conditions. Limit Controls Automatic reset, primary and secondary limits are accurately located. Primary limit factory installed on vestibule panel on all units, secondary limit factory installed on blower housing. Optional Accessories Altitude Pressure Switch Kit Required on most units for proper unit operation at altitudes from 450 to 0,000 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. BLOWER Variable Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on the furnace control. See Blower Performance tables. Blower assembly easily removed for servicing. Variable Blower Motor Variable speed motor maintains specified air volume from 0 though 0.8 in. w.g. (heating) and 0 through.0 in. w.g. () static range. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by furnace control. Motor is resiliently mounted. When furnaces are used with the iharmony Zoning System and the icomfort Communicating Thermostat, the blower motor operates from predetermined minimum - maximum air volumes to satisfy zone requirements. SL80DFV / Page 3

4 FEATURES J CONTROLS SureLight Control (icomfort Communicating) Advanced control communicates information about various operating parameters in the furnace to the optional icomfort Communicating Thermostat to constantly maintain the highest level of comfort and performance available. Auto Configuration - On startup the control automatically sends a description of the unit to the optional icomfort Communicating Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the control. Control also features Innovative AirFlex technology allows custom blower settings based on the application. Thermostat Control - For optimal performance, the use of a high-quality, digital two-stage thermostat with adjustable settings for first stage/second stage, on/off differentials and adjustable stage timers is recommended. Furnace Input Staging Options Thermostat Type Input Staging Available icomfort Communicating Thermostat Two-Stage (Conventional) Single-Stage (Conventional) Two-Stage (65 and 00%) Safety Controls - Flame sensor utilizes flame rectification for safe and reliable operation. Should flame fail to ignite, control will initiate 4 reattempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. Select Thermostat used - Single-Stage or Two-Stage. Two selectable second stage recognition times (7 and minutes) are available on the control when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Heating s - A combination of DIP switch settings allow the following motor speed selection settings within the heating speed selected for fine tuning air volume: Factory default 6%, %, 8% or 4% increase 6%, % or 8% decrease See Blower Performance tables. s - A combination of DIP switch settings allow the following motor speed selection settings within the cooling speed selected for fine tuning air volume: Factory default 0% increase 0% decrease See Blower Performance tables. Blower Ramping ( Mode) - DIP switch settings allow one of four blower speed profiles during cooling operation. Profile A (factory setting) - Motor runs at 50% for 30 seconds, then at 8% for 7-/ minutes, then at 00% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B - Motor runs at 8% for 7-/ minutes and then at 00% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C - Motor runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for 60 seconds, then ramps down to stop. Profile D - Motor runs at 00% until demand is satisfied. Once demand is met, motor ramps down to stop. Dehumidification (Active or Humiditrol Option) - A jumper on the control control must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system. After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. SL80DFV / Page 4

5 FEATURES CONTROLS (continued) Dual-Fuel Operation - A jumper on the control must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two-Stage Compressor Operation - A jumper on the control must be clipped to enable operation with a two-stage compressor. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation (communicating mode). Blower On/Off Time (Heating) - Blower on time is fixed at 30 seconds, blower off time is adjustable from 60, 90, 0 and 80 seconds (factory setting - 90 seconds). Blower On/Off Time () - For air-conditioning applications, blower on time is seconds following thermostat demand for cooling. See Blower Ramping ( Mode) profiles for various blower off details. Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units when used with the icomfort Communicating Thermostat or the ComfortSense 7500 Thermostat. Continuous Blower - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 8%, 38% (default setting), 70% and 00%. Accessory Terminal - One accessory terminal furnished for additional power supply requirements for 0 volt (less than amp) powered air cleaners. One unpowered pair of contacts are provided for humidifier connections and may be connected to 4V or 0V. Control is factory installed in the unit control box. 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-Up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. Optional Accessories icomfort S30 Ultra-Smart Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S30 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or . Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Works with Amazon Alexa-enabled products. Easy to read 7 in. high definition color display (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort S30 Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S30 Thermostat Product Specifications bulletin in the Controls section for more information. SL80DFV / Page 5

6 FEATURES CONTROLS (continued) Optional Accessories icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Service alerts and reminders sent via text message or . Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort Wi-Fi Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort Communicating Thermostat and ComfortSense 7500 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for Humiditrol applications. NOTE - The outdoor sensor is furnished as standard with icomfort Communicating outdoor units, optional for conventional units. Thermostat Thermostat (icomfort Communicating Thermostat or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Optional Accessories Night Service Kit Contains most commonly used service parts: Furnace control Ignitor Flame sensor Gas valve Transformer SL80DFV / Page 6

7 FEATURES K L M CONTROLS (continued) Universal Service Kit - Switches Kit contains: Primary limits (for each model) Pressure switches (for each model) Flame rollout switches (for each model) Secondary limits (for each model) CABINET Low-profile, narrow width cabinet allows easy installation in downflow applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on return air opening for ease of plenum connection. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Cabinet door can be removed without any tools Complete service access. Safety interlock switch automatically shuts off power to unit when inner blower compartment access panel is removed. Gas piping and electrical inlets are provided in both sides of cabinet. FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Downflow Filter Cabinet Filter cabinet mounts directly on top of furnace. A width cabinet includes one filter. B and C width cabinets include two filters. Filter rails are furnished. Front access for servicing. Cleanable filter(s) are furnished. Coil Match-Up All Lennox downflow indoor coils will physically match the furnace supply air opening with the same letter designation (A, B, C, D) as in the furnace model number. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard Method of Test for Determining the Air Tightness of HVAC Equipment. Optional Accessories Downflow Combustible Flooring Base Required for heating only units installed on combustible flooring. Not required in add-on cooling applications. See Dimension drawing. SL80DFV / Page 7

8 SPECIFICATIONS Gas Heating Performance Low Model No. SL80DF070V36A SL80DF090V48B SL80DF090V60C SL80DF0V60C AFUE 80% 80% 80% 80% Input - Btuh 66,000 88,000 88,000 0,000 Output - Btuh 5,000 69,000 70,000 87,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane 3.5 / / / / 0.0 Input - Btuh 43,000 57,000 57,000 7,000 Output - Btuh 35,000 46,000 46,000 59,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / / / / 4.9 static - in. w.g. Heating Connections in. Indoor Blower Electrical Data Flue connection - in. round Gas pipe size IPS / / / / Wheel nominal diameter x width - in. 0 x 8 x 9 x 0 x 0 Motor output - hp / Tons of add-on cooling Air Volume Range - cfm Voltage 0 volts - 60 hertz - phase Blower motor full load amps Maximum overcurrent protection Shipping Data lbs. - package NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE - FURNACES CANNOT BE TWINNED! CABINET ACCESSORIES A Width Models B Width Models C Width Models Downflow Combustible Flooring Base M59 M60 M6 CONTROLS icomfort S30 Thermostat U67 U67 U67 icomfort Wi-Fi Thermostat 0F8 0F8 0F8 Remote Outdoor Air Temperature Sensor (for dual fuel and Humiditrol ) X658 X658 X658 Discharge Air Temperature Sensor 88K38 88K38 88K38 ComfortSense 7500 Thermostat 3H4 3H4 3H4 3 Remote Outdoor Temperature Sensor (for dual fuel and Humiditrol) DOWNFLOW FILTER KITS X658 X658 X658 4 Downflow Filter Cabinet 5W06 5W07 5W08 NIGHT SERVICE KIT No. and Size of filter - in. () 0 x 0 x () 6 x 0 x () 6 x 0 x Night Service Kit 4C98 4C98 4C98 Universal Safety Kit - Switches 89W9 89W9 89W9 Remote Outdoor Temperature Sensor is used with conventional (non-icomfort Communicating) outdoor units (sensor is furnished with icomfort Communicating outdoor units). Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. Optional for service diagnostics. 3 Remote Outdoor Temperature Sensor for ComfortSense 7500 Thermostat must be connected directly to the thermostat, Do not connect it to the SureLight control. 4 Cleanable polyurethane, frame-type filter. SL80DFV / Page 8

9 GAS HEAT ACCESSORIES Input Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas Altitude Orifice Kit LPG/Propane Altitude Orifice Kit ft ft ,000 ft ft ft ,000 ft ,000 ft. 070 No Change No Change 73W36 K5 77W09 73W37 77W 090 No Change No Change 73W36 K5 77W09 73W37 77W 0 No Change No Change 73W35 K5 77W09 73W37 77W HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 4500 ft. above sea level without any modifications. At altitudes above 4500 ft. units must be derated to match information in the shaded area shown below. NOTE - This is the only permissible derate for these units. Input Gas Manifold Pressure (Outlet) in. w.g Feet Feet 750-0,000 ft. Natural Gas LPG/Propane Natural Gas LPG/Propane Natural Gas LPG/Propane Low Low Low Natural Gas Alitude Orifice Kit required. Low Low Low INSTALLATION CLEARANCES - INCHES (MM) Vent Type Type B Type C Sides 0 inches (0 mm) 0 inches (0 mm) Rear 0 inches (0 mm) 0 inches (0 mm) Top inch (5 mm) inch (5 mm) Front -/4 inches (57 mm) -/4 inches (57 mm) Front (alcove) 4 inches (60 mm) 4 inches (60 mm) Front (service) 4 inches (60 mm) 4 inches (60 mm) Floor Combustible Combustible Flue inch (5 mm) 6 inches (5 mm) NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z3.). NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI-Z3.) or applicable provisions of local building codes. Left side requires 4 in. clearance if single wall vent is used on 4-/ in. A width cabinets, and in. clearance on 7-/ in. B width cabinets. Clearance for installation on combustible floor if optional Downflow Combustible Flooring Base is installed between furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z3.. SL80DFV / Page 9

10 DIMENSIONS - UNIT - INCHES (MM) 3-/8 (79) 9/6 (4) D FLUE OUTLET (Top) B RETURN AIR OPENING 9-7/6 (494) 9/6 (4) 9/6 (4) TOP VIEW A B 9/6 (4) -/ (38) Front Panel 7-3/4 (705) 9-7/6 (494) 9/6 (4) AIR FLOW 33 (838) 5-3/8 (37) Right -3/6 (56) Left ELECTRICAL INLET (Either Side) GAS PIPING INLET (Either Side) 6-5/8 (68) Right 7-/8 (8) Left 3/4 (9) C Supply Air 3/4 (9) 9-/4 (489) Supply Air 3/4 (9) FRONT VIEW SIDE VIEW Model No. A B C D in. mm in. mm in. mm in. mm SL80DF070V36A 4-/ / /4 SL80DF090V48B 7-/ / /4 59 SL80DF090V60C SL80DF0V60C / / SL80DFV / Page 0

11 DIMENSIONS - ACCESSORIES - INCHES (MM) DOWNFLOW FILTER CABINET A WIDTH FURNACES (Single Filter) B AND C WIDTH FURNACES (Two Filters) 0-/ (5) 4-/ (368) 0-/ (5) 7-/ (445) B Box (533) C Box FILTER () (533) FILTERS () 7-/ (445) 54 (37) 50-/ (83 ) 33 (838) 33 (838) FILTER ACCESS DOOR FURNACE FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening (W x D) A Box 3-/ x 9-5/8 (343 x 498) B Box 6-/ x 9-5/8 (49 x 498) C Box 0 x 9-5/8 (508 x 498) SL80DFV / Page

12 DIMENSIONS - ACCESSORIES - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE -/ (38) SUPPLY AIR OPENING DOWN FLOW FURNACE -/ (38) B 9-3/6 (503) -/ (38) 7-/4 (69) -3/6 (554) Front Of Furnace A -/ (38) TOP VIEW SIDE VIEW DOWNFLOW COMBUSTIBLE FLOORING BASE FLOOR OPENING Cabinet Width Catalog Number A B C in. mm in. mm in. mm A M59 6-9/ / /4 400 B M60 9-9/ / /4 476 C M6 3-/ /6 50 -/4 565 (559) C DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS Furnace Width 33 (838) Coil Height Overall Height Model Number Coil Width Furnace Width Coil Height Overall Height in. mm in. mm in. mm in. mm CR33-8A-F 7-/ / / /8 97 CR33-4A-F 7-/ / / /8 97 CR33-4B-F 7-/ / / /8 97 CR33-30/36A-F 7-/ / / /8 48 CR33-30/36B-F 7-/ / / /8 48 CR33-30/36C-F / /8 48 CR33-48B-F / CR33-48C-F CR33-50/60C-F 4-/ / /8 76 Coil Width SL80DFV / Page

13 BLOWER DATA SL80DF070V36A BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% % % % Factory Default % % % First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium Factory Default and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 50 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 50 cfm. SL80DF070V36A BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Various External Static Pressures - in. wg. Second Stage Low Med-low Med Low Med-low Med Low Med-low Med SL80DFV / Page 3

14 BLOWER DATA SL80DF090V48B BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% % % % Factory Default % % % First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium Factory Default , and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 380 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 380 cfm. SL80DF090V48B BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Various External Static Pressures - in. wg. Second Stage Low Med-low Med Low Med-low Med Low Med-low Med SL80DFV / Page 4

15 BLOWER DATA SL80DF090V60C BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% % % % Factory Default % % % 00 0 First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium Factory Default , and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. SL80DF090V60C BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Various External Static Pressures - in. wg. Second Stage Low Med-low Med Low Med-low Med Low Med-low Med SL80DFV / Page 5

16 BLOWER DATA SL80DF0V60C BLOWER PERFORMANCE (less filter) 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. () External Static Pressure Range Heating First Stage Heating - cfm HEATING Second Stage Heating - cfm +4% % % % Factory Default % % % First Stage - cfm COOLING Second Stage - cfm Low Medium-Low Medium- Low Medium-Low Medium Factory Default and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 38%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. SL80DF0V60C BLOWER MOTOR WATTS (COOLING) + Setting Factory Default Setting First Stage Motor Various External Static Pressures - in. wg. Second Stage Low Med-low Med Low Med-low Med Low Med-low Med SL80DFV / Page 6

17

18

19

20 REVISIONS Sections Document Description of Change Revised icomfort -enabled to icomfort Communicating. icomfort -enabled no longer means communicating with the advent of the E30 and M30 thermostats. Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 07 Lennox Industries, Inc.

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Blower Bulletin No. 0600 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML9DF MERIT SERIES Downflow Bulletin No. 0589 March 09 Supersedes September 08 AFUE - 9% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL NUMBER

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SLP98UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower Bulletin No. 20577 March 208 Supersedes February 208 MODEL

More information

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES EL96DFV ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower Bulletin No. 060 March 09 Supersedes September 08 MODEL NUMBER IDENTIFICATION EL 96 DF 070

More information

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2. P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

DuralokPlus Aluminized Steel Heat Exchanger G 32 V ENGINEERING DATA GAS FURNACES G32V DAVE LENNOX SIGNATURE COLLECTION Up Flow Two Stage Heat Variable Speed Blower AFUE up to 94.2% Input 75,000 to 125,000 Btuh (22.0 to 36.6 kw) Add on Cooling 2 to 5 Tons

More information

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBA8MV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 080 August 08 Supersedes March 08 Nominal Capacity -. to Tons Optional

More information

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower PRODUCT SPECIFICATIONS OIL FURNACES sl085bv DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower Bulletin No. 0677 August 05 Supersedes September 04 AFUE - Up to 87% Heating Input - 79,000 to

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems PRODUCT SPECIFICATIONS ZONING IHARMONY Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems Bulletin No. 20663 November 207 Supersedes August 205 COMPONENTS AND EQUIPMENT

More information

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

icomfort Residential Communicating Control System Equipment Interface Module (EIM) PRODUCT SPECIFICATIONS CONTROLS EIM icomfort Residential Communicating Control System Equipment Interface Module (EIM) Bulletin No. 20662 November 207 Supersedes August 205 The Equipment Interface Module

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 February 08 Supersedes November 07 Nominal Capacity -. to + Tons Optional

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICATIONS GAS FURNACES ML95UH MERIT SERIES Upflow / Horizontal Bulletin No. 059 March 08 Supersedes February 08 AFUE - 95% Input - 44,000 to,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B E N G I N E E R I N G D T G S F U R N C E S ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 June 20 Supersedes May 20 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh PA C KA G E D G A S / E L E C T R I C LRP14GE Residential - R-410A Bulletin No. 210720 November 2016 P R O D U C T S P E C I F I C AT I O N S Supersedes June 2016 SEER - 14.00 AFUE - 81% 2 to 5 Tons Cooling

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL95UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 065 March 08 Supersedes February 08 AFUE - 95% Input - 0,000 to,000 Btuh Nominal

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System PRODUCT SPECIFICATIONS INDOOR AIR QUALITY EDA DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System Bulletin No. 210430 November 2017 Supersedes April 2017 NOTE - EDA is not applicable

More information

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION PA C KA G E D H E AT P U M P LRP4DF Dual-Fuel Residential - R-40A Bulletin No. 20722 November 206 P R O D U C T S P E C I F I C AT I O N S Supersedes October 206 SEER - 4.00 HSPF - 8.00 AFUE - 8% 2 to

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

ML 1 80 UH 070 X E 36 B

ML 1 80 UH 070 X E 36 B PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX0UHV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 March 0 Supersedes September 0 Nominal Capacity - to Tons Optional

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 February 208 Supersedes November 207 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICTIONS GS FURNCES EL80UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 20660 February 208 Supersedes January 208 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

CB X 32 mv

CB X 32 mv PRODUCT SPECIFICATIONS AIR HANDLERS CBXMV DAVE LENNOX SIGNATURE COLLECTION R-0A Ready - Multi-Position - Variable Speed Bulletin No. 0 October 0 Supersedes July 0 Nominal Capacity -. to + Tons Optional

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

ELITE SERIES Upflow / Horizontal - Two-Stage Heat PRODUCT SPECIFICTIONS GS FURNCES EL280UH ELITE SERIES Upflow / Horizontal - Two-Stage Heat ulletin No. 2063 June 205 Supersedes January 205 FUE - 80% Input - 66,000 to 32,000 tuh Nominal dd-on Cooling

More information

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System PRO SPECIFICATIONS INDOOR AIR QUALITY PCO3S DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System Bulletin No. 210857 April 2018 * icomfort S30 Ultra Smart Thermostat * Not furnished - Order

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat C O N T R O L S icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat P R O D U C T S P E C I F I C AT I O N S Bulletin No. 210538 March 2012 Supersedes October 2011

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120 P R O D U C T S P E C I F I C AT I O N S O I L F U R N A C E S OHR23 ELITE SERIES Horizontal/Downflow ulletin No. 20097 February 20 Supersedes October 200 AFUE - Up to 83.5% Input - 05,000 to 54,000 tuh

More information

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0211 L3 Revised 09 2006 G60DFV(X) G60DFV(X) SERIES UNITS G60DFV series units are mid efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency lower Motor ulletin No. 20825 July 208 Supersedes February 208 FUE - 80% Input - 44,000 to 32,000 tuh Nominal

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A PA C KA G E D E L E C T R I C / E L E C T R I C LRP4AC Residential - R-40A Bulletin No. 079 July 08 P R O D U C T S P E C I F I C AT I O N S Supersedes Janury 08 SEER - 4.00 to 5 Tons Cooling Capacity

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17. PRODUCT SPECIFICTIONS GS FURNCES ML80UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ ulletin Number 49060 June 205 Supersedes June 203 Net Input - 7.4 to 34.8 kw Nominal dd-on Cooling - 0.6 to 7.6 kw MODEL

More information

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016 PA C KA G E D H E AT P U M P LRP4HP Residential - R-40A Bulletin No. 07 November 06 P R O D U C T S P E C I F I C AT I O N S Supersedes October 06 SEER - 4.00 HSPF - 8.00 to 5 Tons Cooling Capacity -,600

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS XP25 DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology Bulletin No. 210854 January 2018 Supersedes Bulletin No. 210659 * icomfort

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

ELITE Series Variable Capacity

ELITE Series Variable Capacity AIR CONDITIONERS XC20 ELITE Series Variable Capacity Bulletin No. 210732 November 2017 P R O D U C T S P E C I F I C AT I O N S Supersedes August 2017 * icomfort S30 Thermostat SEER up to 20.00 2 to 5

More information

GHR32Q/V SERIES UNITS

GHR32Q/V SERIES UNITS Service Literature GHR32Q/V Corp. 0001 L2 Revised 08 2004 This manual contains information pertaining to GHR32 1 through 6 model units. GHR32 series units are high efficiency horizontal or down flow gas

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort

More information

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System Gas Furnaces Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2 System RGJF- Series Up to 94.8% A.F.U.E. Input Rates from 60 to 120 kbtu [17.58 to 35.16 kw] With

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

G32V. Service Literature G32V SERIES UNITS

G32V. Service Literature G32V SERIES UNITS Service Literature G32V SERIES UNITS G32V series units are high efficiency upflow gas furnaces manufactured with DuralokPlus aluminized steel clamshell-type heat exchangers. G32V units are available in

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND FORM NO. G11-500 REV. 1 Supersedes Form No. G11-500 GAS FURNACES RGGE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (U.S. & Canadian Models) Equipped with Comfort Control

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace R802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Corp L12 Revised G24M SERIES UNITS

Corp L12 Revised G24M SERIES UNITS Service Literature G24M series units are mid efficiency gas furnaces manufactured with tubular steel heat exchangers formed of aluminized steel. G24M units are available in heating capacities of 45,000

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER PRPDF6 PRODUCT SPECIFICATIONS SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER FORM NO. PRPDF6-00 (08/207) MODEL NUMBER PRP DF 6 36-090 P - - A PRODUCT TYPE PRP = PREMIUM RESIDENTIAL PACKAGED

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS ML4XC MERIT Series R-40A Bulletin No. 20834 March 209 Supersedes March 208 SEER up to 7.00.5 to 5 Tons Cooling Capacity - 8,000 to 60,000 Btuh MODEL NUMBER IDENTIFICATION

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E. FORM NO. G11-468 REV. 13 Supersedes Form No. G11-468 Rev. 12 GAS FURNACES RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Modulating

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information