EDUCATIONAL TRAINING UNITS

Size: px
Start display at page:

Download "EDUCATIONAL TRAINING UNITS"

Transcription

1 S

2 OUR COMMITMENT TO QUALITY EDUCATION At Imperial Training we strongly believe in providing the HVAC/R student with the knowledge & training for the safe and efficient operation of all types of systems found in our industry. We also believe that prior to going out into the field, the student should fully understand the theory and operational or service techniques behind each specific system. Imperial Training has been providing the finest training units to the educational market for over thirty years. They can be found in high schools, colleges, and so on all over the world. The training units in this catalog represent a wide variety of subjects in the heating, refrigeration and air conditioning industries. The training units range from demonstrating simple concepts to illustrating advanced troubleshooting and servicing techniques. Our expertise certainly does not end here. We can custom design and build trainers to your exact specifications and needs. For custom requirements or applications, please give us a call at (888) Our company s goal is to provide top quality trainers at reasonable prices that fit our customers precise needs. We look forward to working with you. 2

3 MODEL TU-306 REFRIGERATION DIAGNOSTIC CENTER EDUCATIONAL TRAINING UNIT REFRIGERATION TRAINERS Refrigeration diagnostic center provides equipment and diagnostic tools needed to troubleshoot and analyze small refrigeration systems. Trainer includes: Non-conductive maple worktop Heavy-duty mechanic s vise Bench top power supply (115V/230V AC fused, single phase) Vacuum and charging manifold with gauges Two 5 lb. charging cylinders Torch kit Lockable cage for vacuum pump Switchable power supply for vacuum pump Small part storage cabinet Deep vacuum measuring meter Hermetic compressor analyzer VOM with components analyzer Digital thermometer Refrigeration hoses Rapid vapor charging device Manual Transparencies Overall Size: 73 W x 33 D x 65 H Electrical Requirements: 115/230V AC fused, single phase Shipping Weight: 350 lbs. 3

4 REFRIGERATION TRAINERS MODEL TU-420 FUNDAMENTALS OF REFRIGERATION This refrigeration demonstrator uses the 4 main parts of the refrigeration system (condenser, compressor, evaporator and control device) that demonstrate basic refrigeration principles. The components then work together to cool a small enclosed refrigerator compartment fully featured with an electronic temperature control device. Components arranged to illustrate the cycle nature of refrigeration 4 strategically located explosion proof sight glasses with moisture indicators and thermostat permit monitoring of the refrigerant as it circulates throughout the entire refrigeration system Comes completely assembled with fused main power switch, charged with refrigerant and ready to operate Operation manual included Overall Size: 35 W x 13 D x 30 H Electrical Requirements: 115V AC, 60 Hz, 15A Shipping Weight: 115 lbs. 4

5 REFRIGERATION TRAINERS MODEL TU-100 BASIC REFRIGERATION This training unit demonstrates domestic refrigerator and freezers, self-contained air conditioning units and reverse cycle or heat pump systems. Sight glass tubes at inlet and outlet of evaporator and condenser constructed of explosion proof, tie-bolt design Stainless steel drip pans with drains located under each evaporator and condenser Uses popular, brand name components Color-coded valves, gauges and hand valves to bypass various components and change from cooling to heating (heat pump operation) Conditions of refrigerant and oil can be observed under various methods of operation Pressure gauges located at each point in which pressure variation is likely to occur Refrigerant flow to evaporator metered either by capillary tube, automatic expansion valve (AXV), or thermostatic expansion valve (TXV) Evaporator has copper tube coils, aluminum fins, and variable speed blower Condenser with a variable-speed blower A combination low pressure control and high pressure cutout and a thermostatic control with a range of 30 F to 100 F furnished High pressure cutout in the circuit at all times to prevent damage to the compressor Includes a student lab manual and operation manual Compressor: 1 2 HP hermetically sealed reciprocating Refrigerant: HFC-134A Panels: 1 4 thick with 3 4 thick component shelf Overall Size: 36 W x 18 D x 73 H Electrical Requirements: 115V AC; 50/60 Hz; 10A 230 volt available upon request 5

6 REFRIGERATION TRAINERS MODEL TU-105 COMMERCIAL REFRIGERATION This commercial refrigeration trainer is an advanced unit used to train students in commercial refrigeration and air conditioning systems. Sight glass tubes at inlet and outlet of evaporator and condenser constructed of explosion proof, tie-bolt design Cut-out and by-pass valves Hand valves allow malfunctions to be simulated Many control changes are possible Combination low pressure control and high pressure cut-out Thermostatic control with an adjustable range of 30 F to 100 F 2 solenoid liquid line valves Compressor: Single phase, 1/2 HP semi-hermetic (bolted reciprocating-type) 115V AC, 60 Hz, 15 Amp Evaporators: Copper tube coils with aluminum fins and variable speed blower mounted on back of panel Condenser: A forced air-cooled condenser to match compressor capacity Refrigerant: HFC-134A Panels: 1 4 thick with 3 4 thick component shelf Overall Size: 72 W x 18 D x 72 H Electrical Requirements: 115V AC, 60 Hz 230 volt available upon request 6

7 REFRIGERATION TRAINERS MODEL TU-155 INDUSTRIAL REFRIGERATION This trainer enables students to learn principles of commercial and industrial refrigeration systems. Trainer: Self-contained and freestanding with storage space underneath Compressor: Semi-hermetic type with 2 HP capacity Crankcase heater with automatic control system 2 forced air type evaporators have 2 common types of defrost mechanisms complete with solenoids, timers, and associated equipment 2 standard types of water cooled condensers (tube-in-tube and shell-in-tube) supplied and piped to be used with city water and included water tower Hot gas by-pass system keeps operating pressures of the compressor constant regardless of the evaporator level Crankcase pressure regulator allows the compressor to start easily under high evaporator pressures Utility Requirements: city water, drain to water, and means of venting water tower Overall Size: 100 W x 27 D x 74 H Electrical Requirements: Single phase, 220V AC, 60 Hz, 40A (115 VAC, 60 Hz for water tower) Water Tower: 60 Hz, single phase, 60,000 BTU/hour. Shipping Weight: 1300 lbs. Installation and plumbing to city water not included 7

8 RESIDENTIAL TRAINERS MODEL TU-206 RESIDENTIAL AIR CONDITIONING Real world experience in troubleshooting wiring, piping and controls of a working whole house air conditioning unit. Fault insertion with two refrigerant faults and four electrical faults Provides numerous real world problems Refrigeration cycle can be observed Suction and high-pressure refrigeration tubing piped to sight glasses for direct observation of the fluid and gas stages of the refrigeration cycle Pressure, temperature and electrical readings can be made Wiring and piping is in full view as much as possible R-22 refrigerant can be pumped down Optional add-on equipment package provides all the professional tools necessary to complete service checks Trainer includes: Outside condenser fan unit to exhaust heat Inside blower unit with evaporator for cooling Metering device Manifold gauge set for connection to the built-in service valves 2 sets of pre-connected high and low pressure refrigeration gas/liquid gauges Operation Manual describing how the unit works as well as its faults 880-page book with lesson plans and chapter questions Electricals include: Necessary line and low voltage wiring Low voltage transformer and wiring Overall Size: 60 W x 48 D x 73 H Electrical Requirements: 230 VAC; 50/60 Hz; 15A Trainer can be purchased with frame assembled or in two parts. If ordered in two parts, the discharge and suction lines will need to be reconnected using the factory-supplied flare fittings and internal gaskets. 8

9 RESIDENTIAL TRAINERS MODEL TU-406 RESIDENTIAL HEAT PUMP Real world experience in troubleshooting wiring, piping and controls of a working whole house heat pump unit. Fault insertion with two refrigerant faults and four electrical faults Provides numerous real world problems Refrigeration heat pump cycle can be observed Suction and high-pressure refrigeration tubing piped to sight glasses for direct observation of the fluid and gas stages of the refrigeration cycle Pressure, temperature and electrical readings can be made Wiring and piping is in full view as much as possible R-22 refrigerant can be pumped down Optional add-on equipment package provides all the professional tools necessary to complete service checks Trainer includes: Outside blower unit with evaporator to exhaust cold air Inside condenser fan unit to provide heat Reversing valve that is operated through a digital thermostat Metering device Manifold gauge set for connection to the built-in service valves 2 sets of pre-connected high and low pressure refrigeration gas/liquid gauges Operation Manual describing how the unit works as well as its faults 360-page book with lesson plans, chapter questions, and a review section Electricals include: Necessary line and low voltage wiring Low voltage transfor mer and wiring Overall Size: 60 W x 48 D x 73 H Electrical Requirements: 230 VAC; 50/60 Hz; 15A Trainer can be purchased with frame assembled or in two parts. If ordered in two parts, the discharge and suction lines will need to be reconnected using the factory-supplied flare fittings and internal gaskets. 9

10 AFTERMARKET AUTOMOTIVE MODEL TU-103 & TU-203 AUTOMOTIVE AIR CONDITIONING SINGLE SPEED DRIVE MOTOR (MODEL TU-103) This aftermarket automotive trainer is designed to give the student a working understanding of the different components they will find on an automotive air conditioning system. Comes in two models. Standard aftermarket-type auto air conditioner: mounted on simulated auto chassis with firewall and panel modified to provide thermometer wells and pressure taps modified to permit the addition of operating devices Demonstrates installation and servicing 2 HP electric fan drives compressor and condenser 12 VDC power supply operates the compressor clutch and evaporator blowers Refrigerant: HFC-134A Electrical Requirements: 230 VAC, 1 phase VARIABLE SPEED DRIVE MOTOR ADD-ON (MODEL TU-203) Similar to above, but motor is mounted on a variable speed drive allowing an approximate speed ratio of 3 to 1. Permits demonstration of operation at various engine speeds Electric tachometer reads speeds of compressor mounted on a simulated instrument panel Refrigerant flowmeter measures the refrigerant flow in pounds per minute and allows comparison of refrigerating effects at various motor speeds Special purpose controls are installed to demonstrate different control systems Refrigerant: HFC-134A Overall Size: 35 W x 42 D x 43 H Electrical Requirements: 230 VAC, 1 phase 10

11 ELECTRIC MOTORS MODEL TU-503 ELECTRIC MOTOR TECHNOLOGY CENTER Hands on experience with different types of electric motors in various different types of circuits. Perfect for electric motor theory demonstrations. Investigates in detail the fractional horsepower electric motor Examine its theory, construction, proper wiring and maintenance 5 different types of motors: split phase, capacitor start, universal, shaded pole and hermetic compressors are provided with proper test equipment to determine their operating characteristics, performance, starting circuits and control, and their maintenance and troubleshooting The center consists of a cabinet with instrumentation backpanel Special motor mounting base and quick coupler shaft adapter allow for instant hookup of auxiliary motors Backpanel includes an instrumentation section of ammeter, voltmeter and wattmeter to show changing electrical performance under changing loads Also includes a control center that illustrates the function of magnetic contactors with control circuits, terminal board wiring, speed controllers, motor starting relays and short cycle protection Includes an instruction manual with 24 exercises in motor theory Experimental areas: Motor Basics-Universal Motor Magnetic Starters-Lock-Out Relays Motor Electrics-Volts, Amps, Watts Motor Power-Torque and Horsepower Wiring Diagrams for Motor Control The Shade-Pole Motor The Hermetic Compressor Starting Relays and Capacitors Pushbutton Controllers Low Voltage Magnetic Starters Overall Size: 44 W x 27 D x 60 H 11

12 HEATING TRAINERS MODEL TU-208 FORCED AIR & HYDRONIC HEATING The forced air and hydronic heating trainer provides demonstration and service practice with forced air and hydronic heating systems, including hot water heating systems. All components are full size, completely operational and are standard brands of equipment. A student experiment manual specially written for this equipment. Experiments include: Introduction of principles, References, Pre-lab questions, Lab procedure, Post-lab exercises Experiment topics include: Forced air heat pump, Circulation systems, Burner systems, Duct system, Air balancing, Flame safety devices, Temperature and humidity control, Heat transfer devices, Oil fired boiler and burner systems, Draft regulators and piping systems Trainer includes: Heat pump forced air system (gas furnace option available) Oil fired hydronic boiler Air conditioning via reverse heat pump operation Fuel tank sold separately Trainer can be custom built to meet your needs Installation Requirements: Trainer ships in 3 sections, must be assembled upon delivery. Sections include: Main unit, Heat pump unit and Duct Work Oil Supply Water supply required for humidifier (1/4 copper line) and boiler (standard garden hose) Drain required for humidifier Overall Size: 180 W x 48 D x 100 H Electrical Requirements: 100 Amp, 240V 1PH service Shipping Weight: 1,900 lbs TU-208E (shown) utilizes an electric boiler system 12

13 HEATING TRAINERS MODEL TU-701 TABLETOP HEAT PUMP TRAINER Real world experience in troubleshooting wiring, piping and controls on a working heat pump unit. The trainer is perfect for introduction to heat pump theory. Trainer pre-piped, pre-wired with all in complete view Refrigeration heat pump cycle can be observed Pressure, temperature and electrical readings can be made Optional add-on equipment package listed below provides all the professional tools and supplies to practice the skills hands-on Trainer includes: Blower unit with evaporator Condenser fan unit Pre-piped suction and high pressure refrigeration tubing is visible for direct observation of the fluid and gas stages of the refrigeration cycle 360-page book included with lesson plans, questions, and a review section Electricals include: All necessary line and low voltage wiring 120V AC circuit breaker box Overall Size: 32 W x D x 31 H Electrical Requirements: 115V AC; 50/60 Hz; 10A 13

14 HEATING TRAINERS MODEL TU-502 GAS FIRED HEATING CONTROL BOARD The control board contains a complete set of electrical controls of a furnace, with air conditioning, to demonstrate basic principles and provide electrical service experience. All components panel mounted and wires brought to terminals on the front panel Equipped for both thermocouple and thermopile systems Signal lamps show simulated operation of burner valves, circulating fan air and air conditioning compressor Overall Size: 35 W x 13 D x 30 H Electrical Requirements: 115V AC, single phase, 60 Hz Shipping Weight: 130 lbs. 14

15 HEATING TRAINERS MODEL TU-129 OIL FIRED HEATING CONTROL BOARD The oil-fired forced-air control board contains a complete set of electrical controls of a furnace with air conditioning to demonstrate basic principles and provide electrical service experience. Stack relay and cadmium-cell-type flame safety control Heating-cooling thermostat Fan, limit switch, fan relay Overall Size: 35 W x 13 D x 30 H Electrical Requirements: 115V AC, single phase, 60 Hz 15

16 HEATING TRAINERS MODEL TU-302 ELECTRIC HEATING CONTROL BOARD This trainer is perfect for students to learn the basics of electric heat control systems. Trainer includes: Complete set of operating controls of an electric furnace Wired 3 element furnace circuit Simulated heater elements operation shown by signal lamps Sequences Klixon limit switch Fusible link safety device Thermostat Transformer Fan delay control Board designed for use on a bench or table Overall Size: 35 W x 13 D x 30 H Electrical Requirements: 115V AC, single phase, 60 Hz Shipping Weight: 70 lbs. 16

17 MODEL TU-521 SINGLE PHASE COMPRESSOR CONTROL BOARD EDUCATIONAL TRAINING UNIT COMPRESSOR TRAINERS Consists of an actual single phase compressor with components necessary to demonstrate all common types of controls in refrigeration and air conditioning systems. Components are put into the system with patch cords Shut-off valves in suction and pressure lines allow pressures to be varied to operate the low pressure control and high pressure cutout PSC (permanent split capacitors) and running capacitors are supplied for capacitor (capacitive) start systems Overall Size: 35 W x 13 D x 30 H Electrical Requirements: 115V AC, single phase, 60 Hz 17

18 BUILD-UP TRAINERS MODEL TU-501 MOTORS, CONTROLS & CIRCUITS BUILD-UP TRAINER Designed for the student with a working knowledge of the theory of refrigeration electrical control systems. Using this trainer, students are required to design a system to match specifications of a particular situation. Components are quickly mounted on the backboard using wing nuts for maximum flexibility in arranging components. Connections between components are wired by the students. (Mounting hardware must be purchased locally). Trainer components include: Single phase disconnect 24V transformer Duplex receptacle Low voltage thermostat Defrost timer Low-pressure switch High-pressure switch Oil pressure switch Fan/limit switch Heating sequencer Motor starter Start/stop switch Current relay-potential relay Start capacitor-run capacitor Single-phase compressor Capacitor start motor-psc motor Experiment manual Explanations of the theory of operation Enclosed storage compartment Panels: 1 4 thick with 3 4 thick component shelf Overall Size: 36 W x 18 D x 73 H Electrical Requirements: 115/230 VAC, 1 Phase, 60 Hz 18

19 MODEL TU-101 DOMESTIC REFRIGERATION BUILD-UP TRAINER EDUCATIONAL TRAINING UNIT BUILD-UP TRAINERS Companion to the motors, controls and circuit trainer (Model TU-501) described on the previous page. Designed for the student that has a working knowledge of the theory of refrigeration. Using this trainer, students are asked to design a system to match specifications of a particular situation. Instruction kit and experiment manual provide set-up and assembly directions. The double evaporator simulates a dual evaporator system application that demonstrates basic principles and provides service experience. Trainer includes: 1 4 HP hermetic compressor with air-cooled condenser Domestic freezer static evaporator Finned high humidity evaporator Capillary tube Dehydrator Temperature control Hand valve to regulate temperature differences in evaporator Instruction kit and experiment manual Overall Size: 36 W x 18 D x 73 H Electrical Requirements: 115VAC, 50/60 Hz, 10 A Shipping Weight: 300 lbs. 19

20 EQUIPMENT PACKAGES MODEL EP400 RESIDENTIAL A/C AND HEAT PUMP EQUIPMENT PACKAGE Contains test equipment necessary for performing additional experiments and tests with the Residential Air Conditioning (TU-206) and Heat Pump (TU-406) Trainers. Equipment Package includes: CFM Vacuum Pump 2. Super Vak-Check (Model 14571) 3. Fieldpiece Multimeter with Temperature probe and clamp (Model No. TPI-275) 4. Hermeti-Check (Model 2001) 5. Halide Leak Detector Kit (HLD-1201) 6. 1/4in x 5/16in Service Wrench (Model 127-C) 5.0 CFM Vacuum Pump 127-C HLD-1201 TPI MODEL EP100 BASIC AUTOMOTIVE AIR CONDITIONING EQUIPMENT PACKAGE Contains minimum test equipment necessary for performing experiments and tests with auto air conditioning trainers (TU-103 & TU-203). Equipment Package includes: 1. Digital Thermometer (Model SDT-40) 2. Flexible PVC Covered Probe (Model D not pictured) 3. 2 Way Manifold for R22, R134A & R407C (Model 521-CA) 4. 5ft Hose Set & Adapters (3 hoses & 2 adapters - not pictured included with manifold Model 521-CA) 5. Isolation Valve (Model not pictured) 6. Valve Core Depressor (Model 7025) 7. Halogen Leak Detector Kit (Model HLD-1201) 8. Reversible Ratchet Wrench (Model 127-C) 9. ACME Adapter Set (Not pictured) 127-C SDT CA 521-CA HLD

21 MODEL TUE-100 ELECTRONIC WIRING SKILL PACKAGE EDUCATIONAL TRAINING UNIT RESIDENTIAL WIRING TRAINERS Contains test equipment necessary for performing basic electrical wiring for residential applicatons. Package includes: Two octagon boxes Two lamp sockets Two three-way switches Low voltage pushbuttons Low voltage transformer Low voltage buzzer Two duplex outlets Handy and junction boxes Electrical tape Wireless electrical connectors A supply of wire Fluorescent fixture and lamp Also included is a line cord, quantity of NM-B cable, and a copy of the National Electrical Code Book. The unit includes a plywood storage case with a removable cover on which students are able to construct the wiring circuits. Condensed Table of Contents: Introduction The Simple Switch The Single-Pole Double -Throw Switch Continuity Testing Switches Parallel Switches Series Loads Parallel Loads Three Way Switching Low Voltage Circuits Overall Size: 30 W x 24 H x 12 D Electrical Requirements: 120V AC Shipping Weight: 55 lbs. 21

22 RESIDENTIAL WIRING TRAINERS MODEL TUE-200 RESIDENTIAL WIRING DEMONSTRATOR Students gain a full understanding of National Electrical Code residential electrical circuits. Through actual practice, students attain a substantial beginning level skill and proficiency using tools of the electrical trade. Trainer includes: Casters, locking hardware, inter-connecting twist lock plugs and caps to connect the side panels National Electrical Code manual (latest edition) Wiring instruction practices text Test with blueprints on residential wiring Student manual with references Folds to occupy a minimum of floor space Sturdy construction and completely wired Trainer will provide 100-Amp service Typical wiring jobs include: 2 & 3-way switches Lights controlled from 1 or more locations Central distribution with circuit breakers EMT conduit, NM-B cable and greenfield wiring Old and new work practices In-wall and surface mounted wiring devices Low voltage signaling devices, 120 and 240V AC, 3-wire Edison wiring Control and installation-fluorescent lighting Control and installation-incandescent lighting Overall Size: 91 W x 64 D x 84 H Shipping Weight: 500 lbs Ships in two 64 x 84 sections 22

23 MODEL TUE-150 RESIDENTIAL WIRING TRAINER EDUCATIONAL TRAINING UNIT RESIDENTIAL WIRING TRAINERS This Trainer Panel is used to demonstrate electrical principles similar to those found in a residential dwelling. It also has provision for extensive switching and connection of lamps and outlets. The trainer has a 24 volt power supply that is used to wire and test all circuits After the instructor has approved wiring, 115 VAC can be applied using the key-lock circuit breaker control. The ability to use low voltage for testing and 115 VAC for final wiring is a valuable teaching aid. Trainer includes: Low voltage pushbutton doorbell switch Pilot light to indicate low voltage ON A low voltage buzzer Two standard duplex receptacles GFI duplex receptacles Two lamp sockets Pilot light to indicate 120 VAC is ON Two three-way toggle light switches Standard residential 4 circuit breaker panel Dual 24 VAC, 5 Amp pre-test panel with breaker Three wire grounding AC 120V cord Starter quantity of wire for trainer Condensed Table of Contents: Introduction The Simple Switch The Single-Pole Double-Throw Switch Continuity Testing The Breaker Panel Switches Parallel Switches Series Loads Parallel Loads Series-Parallel Loads The inclusion of the dual 24 VAC power supply makes this a very useful trainer for introductory classes, since all initial breadboarding and testing can be done at low voltage and then 115 VAC is only made available to the trainer after the instructor has used the key to turn on the Electro-Lock to apply 115 VAC. Students learn wiring as well as the proper electrical hookups from the manual that is included. All of the above components are mounted on a quality hardwood panel. Overall Size: 36 W x 30 D x 28 H Electrical Requirements: 115 VAC at 15 Amps, 50/60 Hz Shipping Weight: 65 lbs. 23

24 30333 Emerald Valley Parkway Glenwillow, Ohio USA 2015 Stride Tool Inc. Printed in U.S.A

TRAINING UNIT CATALOG

TRAINING UNIT CATALOG UNIT CATALOG Select Training Units now come with an imanifold and probes! TU-406C RESIDENTIAL HEAT PUMP TRAINER imanifold TU-701 TABLE-TOP HEAT PUMP TRAINER TU-100 BASIC REFRIGERATION TRAINER NOR TH PARK

More information

TRAINING UNIT CATALOG

TRAINING UNIT CATALOG UNIT CATALOG Select Training Units now come with an imanifold or iconnect kit! TU-406C RESIDENTIAL HEAT PUMP TRAINER imanifold NEW PRODUCT! TU-805 AIR CONDITIONING AND REFRIGERATION TRAINER TU-100 BASIC

More information

TRAINING UNIT CATALOG

TRAINING UNIT CATALOG UNIT CATALOG Select Training Units now come with an imanifold kit! TU-406C RESIDENTIAL HEAT PUMP TRAINER INCLUDED IMANIFOLD KIT WITH SUBSCRIPTION ALLOWS REAL-TIME PROJECTION IN THE CLASSROOM NEW PRODUCT!

More information

TRAINING UNIT CATALOG SPECIALIZING IN HVAC/R TRAINING

TRAINING UNIT CATALOG SPECIALIZING IN HVAC/R TRAINING UNIT CATALOG SPECIALIZING IN HVAC/R iconnect Select Training Units now come with an imanifold or iconnect kit! TU-406C RESIDENTIAL HEAT PUMP TRAINER INCLUDED IMANIFOLD KIT WITH SUBSCRIPTION ALLOWS REAL-TIME

More information

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs Lesson 1 - Trade Tools Explain the importance of using proper tools and test instruments. List the various types of wrenches and describe their use. Describe the proper procedures for bending, flaring,

More information

Refrigeration and Air Conditioning

Refrigeration and Air Conditioning Refrigeration and Air Conditioning Hampden: The Leader in Real-World Training Hampden Engineering Corporation has been designing and manufacturing educational training devices for engineering, technical,

More information

Air Distribution Systems

Air Distribution Systems Air Distribution Systems Bulletin 227-2B Purpose H-AP-2 Air Distribution System Trainer The Hampden Model H-AP-2 Air Distribution System Trainer is designed to acquaint the student with the fundamentals

More information

Refrigeration Training System

Refrigeration Training System 3401-20 Refrigeration Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals 3 Table

More information

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION REFRIGERATION AND AIR CONDITIONING CUSSONS LABORATORY RECOMMENDATION Cussons Refrigeration laboratories are offered to provide teaching to a range of different skill levels. In all the laboratories teaching

More information

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s) Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY Test Code: 5937 Version: 01 Specific competencies and skills tested in this assessment: Introduction to HVAC Identify HVAC systems Demonstrate

More information

Jr. Tech (JT-1, 2, 3) Knowledge Areas

Jr. Tech (JT-1, 2, 3) Knowledge Areas Jr. Tech (JT-1, 2, 3) Knowledge Areas The Jr. Tech Level includes technicians that are just entering the business and are in the beginning stages of their HVAC-R training and development. Over this period

More information

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12 Prentice Hall Fundamentals of HVAC/R 2010 Grades 9-12 C O R R E L A T E D T O HVACR High School ISBN's 9780132223676 SE / 9780132224055 IG Grades 9-12 A. SAFETY (1) Identify types, purposes, and operation

More information

3400-3A Refrigeration System Demonstrator

3400-3A Refrigeration System Demonstrator 3400-3A Refrigeration System Demonstrator LabVolt Series Datasheet Festo Didactic en 240 V - 50 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC) Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC) Test Code: 3080 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

DIABLO VALLEY COLLEGE CATALOG

DIABLO VALLEY COLLEGE CATALOG HEATING, VENTILATION, AIR CONDITIONING, REFRIGERATION - HVACR Open, Dean Workforce Development and Engineering Technologies Administration Building, Room 121 can earn awards at three levels of completion:

More information

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain

More information

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning Blueprint HVAC - Heating, Ventilation and Air Conditioning Test Code: 0144 / Version: 02 Specific Competencies and Skills Tested in this Assessment: Electricity Demonstrate understanding of basic AC/DC

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout c. All contestants are required to remain in the contest area until the contest has been torn down and excused by the Chairperson. Note: Your contest may also require a hard copy of your résumé as part

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid Unit/Standard Number High School Graduation Years 2016, 2017, and 2018 Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP 47.0201 Task Grid Secondary Competency

More information

Heating, Ventilation & Air Conditioning (HVAC)

Heating, Ventilation & Air Conditioning (HVAC) Job Ready Assessment Blueprint Heating, Ventilation & Air Conditioning (HVAC) Test Code: 3045 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Electricity

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016 This Table of Contents lists the complete contents of the RSES s (SAM) issued to date. Section 1 Refrigeration 620-05 Principles of Refrigeration Part 1 620-06 Principles of Refrigeration Part 2 620-67

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

Geothermal Training System

Geothermal Training System 46126-00 Geothermal Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 05/2018 Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4 Domestic

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High

More information

PART 3 Refrigeration & Air Condition System

PART 3 Refrigeration & Air Condition System PART 3 Refrigeration & Air Condition System ED-5850/5850GL ED-5851/5851GL ED-5852/5852GL ED-5853 ED-5854 ED-5855 ED-5856 ED-5858 ED-5859 BASIC REFRIGERATION SYSTEM BASIC REFRIGERATION & FREEZING SYSTEM

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00 BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from

More information

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge. Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

Geothermal Training System (46126-A0)

Geothermal Training System (46126-A0) Geothermal Training System 582385 (46126-A0) LabVolt Series Datasheet Festo Didactic en 220 V - 60 Hz 03/2019 Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4

More information

Heat Pump Training Course 128 hours, 128 NATE CEHs, 12.8 CEUs Volume Pages, Volume Pages

Heat Pump Training Course 128 hours, 128 NATE CEHs, 12.8 CEUs Volume Pages, Volume Pages Volume 1 Lesson 1 - Heat Pump Fundamentals Explain principles of physics that apply to heat transfer and the refrigeration cycle. Explain the relationship between heat quantity and heat intensity. Explain

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8 SERVICE UNIT INFORMATION Corp. 9121 L7 CHA16 2 5 TON UNITS Litho U.S.A. CHA16 series units in the 2 5 ton sizes were introduced in the spring of 1990. The single package cooling units may be used in both

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

Refrigeration and. Modern. Air Conditioning. Bracciano, BS, M.Ed., Ed. Sp. Alfred F. Andrew D. Althouse, BS, (ME), MA. Carl H. Tumquist, BS, (ME), MA

Refrigeration and. Modern. Air Conditioning. Bracciano, BS, M.Ed., Ed. Sp. Alfred F. Andrew D. Althouse, BS, (ME), MA. Carl H. Tumquist, BS, (ME), MA Modern Refrigeration and Air Conditioning by Andrew D. Althouse, BS, (ME), MA Technical-Vocational Education Consultant Life Member, American Society of Heating, Refrigeration, and Air-Conditioning Engineers

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

SERVICING S-15 CHECKING CAPACITOR

SERVICING S-15 CHECKING CAPACITOR S-15 CHECKING CAPACITOR The direct drive motors are of the permanent split capacitor design. A run capacitor is wired across the auxiliary and a portion of the main windings. The capacitors primary function

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers RED DOT UNITS R-1630 Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL The R-1630 combines powerful heating and cooling with the compact profile you need for tight spaces. It easily

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

CURRICULUM BREAKDOWN

CURRICULUM BREAKDOWN CURRICULUM BREAKDOWN TWO YEAR CURRICULUM - TECHNICAL COLLEGE FIRST YEAR FIRST SEMESTER Reading Blueprints Reading Schematics and Symbols Using Mathematics in the Plant Making Measurements Metals Non-Metals

More information

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE - SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Air Conditioning, refrigeration and Appliance Transformers

Air Conditioning, refrigeration and Appliance Transformers Air Conditioning, refrigeration and Appliance Transformers 10 Section An economical approach to changing world voltages to 115V for operation of air conditioners, refrigeration equipment, appliances, business

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series HEAT PUMPS 7.5 TO 10 TONS 506148 01 12/08 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act of 1990 bans the intentional

More information

SERVICE MANUAL FOR MODEL RM-49

SERVICE MANUAL FOR MODEL RM-49 SERVICE MANUAL FOR MODEL RM-49 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

OPERATION AND SERVICE for

OPERATION AND SERVICE for T-313 Manual OPERATION AND SERVICE for 68RM50-100/101 MICROMAX T-313 REV. 07/2012 2012 Mobile Climate Control SAFETY SUMMARY GENERAL SAFETY NOTICES The following general safety notices supplement the specific

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

Reach-In Refrigerators and Freezers Service Manual

Reach-In Refrigerators and Freezers Service Manual Reach-In Refrigerators and Freezers Service Manual Part No. 80-0899-3 Rev. A 11/96 Safety Notices As you work on the Reach-In, be sure to pay close attention to the safety notices in this manual. Disregarding

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-42 22 16.00 40 (August 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-42 22 16.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

Glass Door Merchandiser. Model RM-49

Glass Door Merchandiser. Model RM-49 Glass Door Merchandiser Model Number: Issued: 02-22-2017 Revised: 02-22-2017 2 TABLE OF CONTENTS UNIT FEATURES 4 Page CROSS SECTION VIEWS 5 EXPLODED VIEW 6, 7 REFRIGERATION SYSTEM 8, 9 CONDENSING UNIT

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Unit Objectives After studying this chapter, you should be able to: Describe hand tools used by the air-conditioning, heating,

More information

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment. Unit Objectives 3/1/2012. General Hand Tools (1 of 6)

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment. Unit Objectives 3/1/2012. General Hand Tools (1 of 6) Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment Unit Objectives After studying this chapter, you should be able to: Describe hand tools used by the air-conditioning, heating,

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information