1 www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety Information Attention/Caution Pressurized Equipment: Never exceed the maximum working pressure indicated on the dryer data tag. Ensure dryer is fully depressurized and all electrical power is disconnected before working on the dryer. Electrical: Always install dryers in accordance with local electrical codes and standards. This dryer is not NEMA 4 or 7 rated and should not be installed in unprotected or potentially explosive areas. Air for Respiration: The air treated by this dryer should not be used for human respiration (breathing air) without approved monitoring controls and may require further additional and or specific air purification and treatment. Consult the OSHA norm regarding the necessary quality of compressed air for respiration or contact NewGate Technologies, Inc. for breathing air applications SW 7 th Road, Ocala, FL 34474, USA Tel: (352) Fax: (352)

2 Warranty This equipment is warranted for a period of 12 months from date of installation or 18 months from date of shipment (whichever occurs first) against defects in materials and workmanship. Call NewGate Technologies prior to performing all warranty work for authorization or return of product. This warranty covers all components of the dryer, with the following exceptions: - Electrical components (motor, fans, pressure switches, etc.) are covered for 6 months. - Electronic circuits including lamps and fuses are covered for 3 months. - Field adjustments to dryers to meet local conditions and which are different from standard factory settings is considered normal maintenance and not covered by warranty. The warranty is void if or for the following reasons: - Dryer identification data tag is removed or altered. - Repair or maintenance is performed without prior authorization by NewGate Technologies, and/or by unqualified personal. - If installation and maintenance procedures are not strictly adhered to and as specifically outlined in this operations manual. In the case of a manufacturing defect, call NewGate Technologies Inc. or your authorized dealer for repair or replacement. If authorization is given to return the product to NewGate Technologies Inc, the customer must pay the freight, whereas NewGate Technologies Inc will pay the return freight. If the dryer is not covered by warranty, or no warranty related defect is found, all freight costs are the responsibility of the customer. Total liability is limited to the total cost of the dryer only. This warranty covers the replacement or repair of the equipment only. Any other incurred costs or losses associated whether directly or indirectly with a defect in the dryer, are not covered by this warranty. NewGate Technologies, Inc. dryers are manufactured to meet or exceed ISO-7183-B international standards. Page 2 of 16

3 1.0 DESCRIPTION 1.1 How it works 1.2 Air circuit Refrigerant circuit Evaporator control Condenser control 1.4 Electrical circuit 2.0 INSTALLATION 2.1 Inspection, Damage and Handling 2.2 Location and Installation 2.3 Electrical connection 2.4 Condensate drain connection 3.0 OPERATION 3.1 Start up 3.2 During operation 4.0 MAINTENANCE 4.1 Condensers & Coolers 4.2 Internal Cold coalescing filter 4.3 Drain system 4.4 Electrical system 4.5 Trouble shooting guide 5.0 GENERAL ARRANGEMENT DRAWING 6.0 ELECTRICAL SCHEMATIC 7.0 FLOWCHART 8.0 TABLES Index 8.1 Capacity correction table 8.2 Control parameters table 8.3 Power Consumption, Amperage & Water Consumption table 9.0 MICROPROCESSOR CONTROLLER 9.1 Analog Controller Page 3 of 16

4 1.0 DESCRIPTION 1.1 How it works Compressed air leaving the compressor is very hot and is completely saturated (RH 100%). It therefore contains a large quantity of water in the form of vapor. As the air flows in the pipeline, its temperature continues to drop, and condensation in the form of liquid water occurs. A mechanical or coalescing condensate separator or filter must now remove this water, else it will cause problems to components downstream. However, none of these devices can remove the water vapor that is still present in the air. For most applications this is an unacceptable condition and the air needs to be dried. The most common form of drying is through the process of refrigeration. This procedure involves further cooling of the compressed air to a lowest possible temperature of about 38º F and then separating the resultant liquid condensate. Subsequently, the dry but cold air is re-heated by the incoming hot air, and is delivered to the plant. The mechanical separation of the liquid condensate from the air is a critical function and is accomplished in NewGate s dryers with a our G Series cold coalescing filter rather than by relying on inexpensive and inefficient mechanical separation methods. The removal of liquid oil, which also drops out of vapor state along with the water, is also accomplished most efficiently at this stage by the coalescing filter. This is a significant benefit to our customers, and guarantees no further condensation of oil vapors will occur further down in the plant air stream. The air is now considered oil free for all practical purposes. All NewGate Technologies dryers are designed to International ISO standard 7183-B. 1.2 Air circuit (see also 7.0) In the Synergy High Inlet Temperature dryers, cooling of the air is done in three stages. In the 1 st stage, the compressed air is cooled in the air-cooled aftercooler, where the air temperature is brought down to about 110 ºF. The air is then processed in the integrated coalescing filter/separator, where all of the liquid water condensed in the afttercooler is separated and removed via an electronic drain valve. The air is now ready to proceed to the refrigerated dryer section of the package. In the refrigerated dryer section, the cooling of the air is done in two stages. In the 1 st stage air-to-air heat exchanger (pre-cooler/re-heater), the temperature of the hot incoming air is reduced by the cold outgoing air, which is at the same time re-heated during the heat exchange process. The incoming air then enters the 2 nd stage air-to-refrigerant exchanger (evaporator), where the air temperature is further reduced to about 38ºF dew point. At this point, the maximum amount of water and oil is condensed and removed through the cold coalescing filter electronic drain valve. The dry air now re enters the air-to-air heat exchanger and is reheated to about 80ºF before exiting the dryer to the plant. 1.3 Refrigerant circuit (see also 7.0) After compression the refrigerant is a high pressure and high temperature gas. The refrigerant gas then enters the water or air cooled condenser where it changes to a liquid at high pressure. This liquid refrigerant then passes through a drying filter and through an expansion valve where the high pressure liquid is allowed to expand back to a gaseous state. It is then directed into the air-to-refrigerant heat exchanger (evaporator) at a temperature of approximately 28ºF. In the evaporator, the entire liquid refrigerant converts back into a low pressure gas and returned to the refrigerant compressor inlet. This cycle repeats itself. NewGate Technologies, Inc. uses only EPA approved R22, R134a and R404 refrigerants. Page 4 of 16

5 1.3.1 Evaporator control When a reduction of the thermal load occurs (because of reduction of incoming airflow or air temperature), the refrigerant temperature and pressure in the evaporator will also reduce, and this could lead to a potential freezing of the liquid water on the air side of the evaporator in the dryer system. To avoid this potential to freeze, a hot gas by-pass valve is utilized. This valve deviates hot gas from the compressor hot discharge directly into the evaporator (by-passing the condenser), resulting in an increase in the thermal load and effectively preventing freezing. This valve can be adjusted to attain the parameters of table 8.2, or to compensate for actual field conditions that may differ from factory set standards Condenser control In certain circumstances, if low ambient temperatures or low thermal loads occur, there is a tendency for the refrigerant discharge pressure (downstream of the condenser) to be reduced too much. In certain dryer models this reduction in the discharge pressure could compromise the functions of the expansion and hot gas by-pass valves. These models are therefore equipped with an additional control device. In dryers equipped with water-cooled condensers, this device consists of a valve installed at the water intake along with a refrigerant discharge pressure sensor. The valve turns on and off based on a pre-determined discharge pressure value. With the water off, the condenser cooling is reduced. This in turn increases the discharge pressure. A constant refrigerant discharge pressure is thus maintained. Air-cooled models are equipped with a pressure switch that controls the condenser cooling fan. Again, by turning the cooling fan on and off, a constant refrigerant discharge pressure is maintained. 1.4 Electrical circuit SYNERGY Dryer Models 025 to 080 are 115/1/60 models and are equipped with a standard power cord with a molded and grounded plug. SYNERGY Dryer Models 100 and 125 are 230/1/60 models, requiring electrical hook-up by a qualified electrician. An internal junction box is provided for this connection. The user is responsible for providing a fused electrical circuit with a capacity as outlined in Table 8.3. Once the electrical power connected to the dryer, the dryer system can be turned on by pressing the Power-On button located on the front panel. The entire system comes on live, including the refrigerant compressor, fans, automatic drain etc. In certain models, the start up of the compressor is assisted by a capacitor and start relay. All models have a thermal overload protection switch in the event of high temperatures and electrical overload conditions. If actuated, it can take up to 2 hours for this protection device to reset. The condenser fan is automatically switched on when the dryer is started. The automatic drain consists of an electronic circuit that actuates a solenoid valve at intervals that can be adjusted. 2.0 INSTALLATION 2.1 Inspection, Damage and Handling It is the sole responsibility of the customer to fully inspect all merchandise prior to accepting the products from the freight company and to immediately make a claim with the freight company for any damages found. NewGate Technologies, Inc. cannot accept any responsibility for any freight damage once the unit has left our facility. Page 5 of 16

6 Unless otherwise specified, dryer models SYNERGY 025 to SYNERGY 125 are packed in corrugated cardboard boxes. Units should be unloaded with a forklift or an appropriate device. 2.2 Location and Installation Location The installation area must be well ventilated in order to avoid elevated ambient temperatures, which will negatively effect the performance of the dryer, especially the air-cooled models. All dryers must be permanently covered from the elements and from freezing temperatures at all time. Only equipment specially designed for outside installation can be placed outdoors without protection. Enclosed compressor rooms are natural dryer installation sites, but be cautious and ensure that these areas are properly ventilated and have ambient temperatures not exceeding 80ºF. The unit should be installed on a firm, level base or floor. Tall units should be bolted permanently to the floor or base utilizing the bolt holes provided. Connecting piping should be free of vibration. Where vibration exists, special flexible connections should be used and installed. Always leave adequate space around the unit for proper operation, maintenance and cooling. Insure adequate cross flow ventilation at all times. It is a good practice to install a bypass around the dryer to allow for routine maintenance without interrupting the process airflow. Any by-pass valves utilized ideally should have a special device to avoid the accidental opening of it Install the dryer in following sequence: Air compressor Air receiver NewGate G Series Filter NewGate SYNERGY Dryer 2.3 Electrical connection Dryer models come in different amperage ratings and should be supplied with a dedicated and properly fused power supply. Follow all local electrical codes and utilize a qualified electrician for all electrical connections. Verify the electrical requirements for each dryer against the electrical diagram in this manual and as indicated on the data tags on every dryer. Proper electrical grounding is a must in order to prevent electrical shock that could result in death or serious injury. 2.4 Condensate & Drain system On all units, the automatic drain valve comes with a plastic tube for piping away liquid condensate. This condensate will contain coalesced oils and should be treated based on local and state codes for condensate discharge. It is critically important that liquid condensate is properly and freely removed from the dryer, else re-entrainment will occur. Therefore, continuously inspect and monitor dryer for proper electronic drain valve operation and for clogged or damaged/bent discharge piping. Page 6 of 16

7 3.1 Start up 3.0 OPERATION On initial start-up on all Synergy dryers, allow the unit to warm up for at least 10 minutes prior to allowing airflow through the unit. When opening or closing the compressed air valves, always do so slowly, in order to avoid shock or damage to the heat exchangers and coalescing filters, and piping system. Failure to follow these instructions immediately voids dryer warranty. 3.2 During Operation Regularly check the automatic drain valve(s) operation and ensure that condensate is being discharged normally. Since there is generally a fairly large amount of water being discharged on a continuous basis, watch this operation. On models with a condenser control device, the fans start and stop suddenly during normal operation. During very hot days they may operate constantly. Use caution when in and around these dryers during normal operation. 4.0 MAINTENANCE Your dryer will require very little maintenance, however, it is recommended you inspect them at least once a day. An authorized NewGate Technologies serviceman must carry out more comprehensive maintenance. Ensure that on air-cooled models the condensers are kept clean and free from debris or become blocked. This is the most common and most serious form of dryer failure and is easily preventable. 4.1 Coolers & Condensers CAUTION! Fans start automatically Disconnect power before any maintenance/service. Always disconnect the dryer from the power supply before working on the dryer, and to avoid injury from rotating fan blades. Inspect and clean the coolers and condensers and free any debris from the coils. Be sure not to bend the aluminum fins on the cooler and condenser coils. Caution: If it is necessary to remove the fan blade, be sure to mark its direction and position so that you can reinstall it to the original factory settings. Reversed fan blades will cause serious performance problems and reduce the life of the unit. Page 7 of 16

8 4.2 Internal Cold Coalescing Filter All SYNERGY dryers come equipped with an internally installed Coalescing Separator/pre-filter and a Cold Coalescing Filter as standard. The first element replacement should be made within the first 900 hours of operation. Subsequently, replace the elements every hours or when the filter change out indicator on the control panel located on the front of the dryer lights up. Considering the possible chemical degradation of the filter element components, it is always advisable to change out the element at least once a year. Other considerations: Filter elements become progressively blocked over time, and therefore require more compressor energy to drive the air through them. A simple calculation based on your cost of energy per kilowatt-hour can help determine the right time to change filter elements in your compressed air system. NewGate Technologies s engineering staff can assist with this analysis, and help you save valuable energy costs. 4.3 Drain system The electronic drain should be inspected once a week. If it does not drain correctly, it might be blocked with dirt. Dismantle the solenoid valve and clean it with compressed air or water. CAUTION! The dryer is under pressure Before dismantling the solenoid valve close the ball valve. CAUTION! Always disconnect the power supply before any maintenance or electrical work is performed. Page 8 of 16

9 4.4 Filter Change-out All Synergy dryers have an LED readout located on the control panel, indicating when the cold coalescing filter should be changed. The very high cost of pressure drop should also be considered in determining when filters should be changed out. Typically, the ideal time to change is when the cost of pressure drop exceeds the cost of the replacement filter element. This will vary depending on location and energy costs in your area. Contact NewGate technologies, Inc. for assistance and guidance. See illustration on next page. Filter element replacement for models SYNERGY 010 to SYNERGY 125: Page 9 of 16

10 4.5 Troubleshooting Guide High pressure drop across dryer Water in compressed air, High dew point Dryer design capacity exceeded 1 Saturated coalescing Filter 5 A. SYNERGY dryer is cooling properly B. SYNERGY dryer is not cooling properly Internal freeze up 6 Low inlet air pressure 25 Capacity too high 1 Refrigerant compressor is running Refrigerant compressor is not running Pulsating flow 3 Drain not functioning 4 Low refrigerant 11 Broken compressor 14 Coalescing filter by-passed 7 Cooling flow blocked 9 Thermal protection activated 15 Incorrectly adjusted hot gas Blown control fuse 16 by-pass valve 12 Broken/loose wiring 18 Air flow too high 1 High inlet air temperature 8 Dirty condenser 10 Expansion valve damaged 13 Dirty filter(s) 24 Ambient temperature too high 2 Refrigerant compressor does not run Refrigerant compressor has no power Pressure switch A/B closed Pressure switch A/B open Pressure switch A/B open (Possible Reason for A/B open) Blown control fuse 16 Power switch off 17 Loss of refrigerant 20 Reset pressure switch Broken electrical circuit 18 Adjust pressure switch 21 If the problem repeats: Broken switch 17 Fan(s) stopped Fan(s) running Broken fan motor(s) 22 High ambient temp. 2 Adjust pressure switch 23 High air inlet temp. 8 Broken electrical circuit 18 High Inlet air flow rate 1 Blocked ventilation 9 Dirty condenser 10 Page 10 of 16

11 1. High inlet air flow rate (Capacity too high) Check the actual flow conditions against rated capacity. See Correction factors in Table High ambient temperature Make sure temperatures are not above 100/110 F. See Correction factors in Table Pulsating flow If the use of air is very inconsistent and fluctuates, an air receiver of adequate size should be installed after the SYNERGY dryer. 4. Drain is not operating Check timer or the solenoid valve. If the coil is energized, the problem could be inside the valve. Disassemble the valve and clean it internally with compressed air or water. 5. Coalescing filters saturated Replace coalescing filter element, using OEM approved elements only. 6. Internal freeze-up Call NewGate Technologies or authorized dealer for technical assistance. 7. Air by-passing the coalescing filters The filter elements may be damaged or incorrectly installed. Check, reposition or replace. 8. High compressed air temperature Check if the compressed air temperature is above 250 F. 9. Condensers air flow blocked The Synergy dryer should be installed in such a way that the inlet and outlet of both cooling airflows are not obstructed. The inlet should receive clean and fresh air. If necessary, relocate the dryer. 10. Dirty After-Cooler/Condenser Clean the condenser as explained in Chapter Low refrigerant pressure Call NewGate Technologies or authorized dealer for assistance. 12. By-pass valve out of adjustment Call NewGate Technologies or authorized dealer for assistance. 13. Damaged expansion valve Call NewGate Technologies or authorized dealer for assistance. 14. Compressor failure Call NewGate Technologies or authorized dealer for assistance. 15. Thermal protection/overload actuated Wait for up to 2 hours. Try to restart. If the compressor terminals are energized and the compressor does not start, it is probably broken/seized. Call NewGate Technologies or authorized dealer for assistance. 16. Control fuse blown Replace control fuse. If fuse repeats to blow, look for a short circuit in the control system (drain, temp. indicator, alert lights, etc.). 17. Power On/Off switch not working The power On/Off switch may be switched off or interrupted. If off, switch it on. If faulty, replace the switch. 18. Electric short circuit There could be a short or loose wire/connector in the wiring control circuit. Check and repair. 20. Refrigerant low or out Call NewGate Technologies or authorized dealer for assistance. Also check for signs of refrigeration compressor oil leaks that indicate location of leak. 21. Pressure switch needs adjusting Call NewGate Technologies or authorized dealer for assistance. 22. Broken fan motor If the fan receives power but does not rotate, replace motor. 23. Pressure switch for condenser control defective Call NewGate Technologies or authorized dealer for assistance. 24. Refrigerant filter/dryer ice up If the filter/dryer shows signs of icing, it may be blocked with dirt from a contaminated refrigerant system. Call NewGate Technologies or authorized dealer for assistance. 25. Low operating pressure Inlet pressure to the SYNERGY dryer is below nominal and design conditions. Increase pressure at the inlet to the dryer. Page 11 of 16

12 5.0 GENERAL ARRANGEMENT DRAWING Models SYNERGY 025 to 125 Page 12 of 16

13 6.0 ELECTRICAL SCHEMATIC Models SYNERGY 025 to 125 Page 13 of 16

14 7.0 FLOWCHART Models SYNERGY 025 to SYNERGY 125 Page 14 of 16

15 8.0 TABLES 8.1 CAPACITY CORRECTION TABLES AMBIENT TEMPERATURE Temp. F F A INLET AIR TEMPERATURE Temp. F F I OPERATING PRESSURE Press. Psig F P C F = Corrected Flow N F = Nominal Dryer Flow C F = N F x F A x F I x F P 8.2 CONTROL PARAMETERS TABLE Parameter SYNERGY-025 to SYNERGY-080 SYNERGY-100 and SYNERGY-125 Refrigerant Suction pressure (PSIG) 58 to to 60 Suction superheat ( F) 5 to 11 5 to 11 Refrigerant R134a R22/R404a 8.3 POWER CONSUMPTION & AMPERAGE TABLE MODEL 100 psig POWER CONSUPTION (WATTS) AMPERAGE (AMPS) (SCFM) 115/1/60 230/1/60 SYNERGY SYNERGY SYNERGY SYNERGY SYNERGY SYNERGY Page 15 of 16

16 9. MICROPROCESSOR CONTROLLER 9.1 ANALOG CONTROLLER (All Synergy Models) How it functions: The panel consists of 3 LEDs indicating the operation of the dryer and 1 test button for the drain system. The first LED (red) indicates if the equipment is switched on (lighted) or off. The second LED (green) indicates if the drain is activated or not. Each time the drain opens, this LED will light up. The third LED (red) indicates that the internal filter is saturated. For proper operation of the dryer it is necessary to replace the filter element when this lights up, as shown in 4.2. The Analog panel is illustrated below: Page 16 of 16

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact: 7610.724.11B 10/01 INSTRUCTION MANUAL Contents 1.0 INSTALLATION... 2 2.0 OPERATION... 3 3.0 MAINTENANCE... 4 TROUBLESHOOTING GUIDE... 6 SPECIFICATIONS... 7-8 ELECTRICAL SCHEMATICS... 9 DIMENSIONS AND WEIGHTS...

More information

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250 MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Refrigerated Air Dryers

Refrigerated Air Dryers WRD Series Innovative Compressed Air Products Refrigerated Air Dryers. Innovative, High Quality, and Cost Effective Refrigerated Air Dryers Leading Edge Technology CORPORATION DEW POINT 0 10 15 C 32 50

More information

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 500 NORTH OAKWOOD RD LAKE ZURICH, IL,60047 PHONE # (847)

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

PDF Created with deskpdf PDF Writer - Trial ::

PDF Created with deskpdf PDF Writer - Trial :: Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights

More information

ClimaGuard Outdoor Heat Exchanger All Models

ClimaGuard Outdoor Heat Exchanger All Models INSTRUCTION MANUAL ClimaGuard Outdoor Heat Exchanger All Models Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200 www.mcleanparts.net

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

RPI Industries, Inc.

RPI Industries, Inc. RPI Industries, Inc. AIR SCREEN and SELF-SERVE OPERATION AND SERVICE MANUAL WARRANTY INFORMATION For Models Stratus SCRFC48R-SSI SCRFC60R-SSI SCRFC72R-SSI SCRFC48R-SSII SCRFC72R-SSII SCRFC48R-SSIII SCRFC72R-SSIII

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS AquaArctic Remote Water Chiller A9100080 -A TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894

More information

CPC PRODUCT DESCRIPTION

CPC PRODUCT DESCRIPTION CPC 40 60 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPC 40-60 compressor is a quiet, complete and readyfor-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO

More information

A Division of Numatics. 201 Series Refrigerated Air Dryer. Models UA through UA Installation, Operating, & Maintenance Manual

A Division of Numatics. 201 Series Refrigerated Air Dryer. Models UA through UA Installation, Operating, & Maintenance Manual A Division of Numatics 201 Series Refrigerated Air Dryer Models UA201-10 through UA201-2000 Installation, Operating, & Maintenance Manual Introduction This manual contains information and recommendations

More information

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES ADVANTAGE RP55 SERIES Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY

More information

Refrigerated Compressed Air Dryer

Refrigerated Compressed Air Dryer Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 10 SEER Standard Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with

More information

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page 600-10,000 scfm AES Series AES Series Energy Saving Refrigerated Air Dryer 600-10,000 scfm Front Page 1 AES Series Energy Saving Refrigerated Air Dryer 600-10,000 scfm Since 1994, Aircel has been delivering

More information

HEATLESS REGENERATIVE DRYERS

HEATLESS REGENERATIVE DRYERS HEATLESS REGENERATIVE DRYERS PHL SERIES Pioneer Air Systems Inc. 210, Flatfork Road, Wartburg, TN - 37887 Tel. : (423) 346-6693 Fax : (423) 346-3865, (423) 346-7522 Email : sales@pioneerair.com Internet

More information

CH750, CH751 & CH951 CHILLERS

CH750, CH751 & CH951 CHILLERS CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com

More information

PROAIR Air Conditioner

PROAIR Air Conditioner INSTRUCTION MANUAL PROAIR Air Conditioner CR29 Protecting Electronics. Exceeding Expectations. Pentair Technical Products Rev. D 2011 Pentair Technical Products P/N 10-1008-121 89055732 TABLE OF CONTENTS

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department

More information

REFRIGERATED AIR DRYERS

REFRIGERATED AIR DRYERS QUINcy qpcd series CYCLING QUINcy qpnc series NON-CYCLING REFRIGERATED AIR DRYERS QPCD CYCLING DRYER, QPNC NON-CYCLING Cycling and non-cycling designs for maximum system efficiency Balanced refrigeration

More information

Refrigerated & Desiccant Compressed Air Dryer Product Selector

Refrigerated & Desiccant Compressed Air Dryer Product Selector Refrigerated & Desiccant Compressed Air Dryer Product Selector ASD and HTD Series Refrigerated Dryer Units DD Series Desiccant Dryer Units Service Parts For faster service and to avoid errors, please use

More information

Glass Door Refrigerators

Glass Door Refrigerators To better help you obtain assistance or service should you ever need it, write down the following information about the product. This information is on the identification label located on the left hand

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Models INSTRUCTION MANUAL Rev. I 2017 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS Warranty and Return Policy...2

More information

THERMAL SYSTEMS, INC. Installation and Operation Manual

THERMAL SYSTEMS, INC. Installation and Operation Manual THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm INSTRUCTION MANUAL DHW Series Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm FORM NO.: 3215738 REVISION: 07/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870 Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870 Table of Contents Troubleshooting Diagnostic Codes... 2 E1... 2 E2, E3... 3 E4.4 E5, E6... 7 E7, E8... 8 E9.9 Verifying Capacity...

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner NPT SERIES K_A6C_NPT47L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner NPT SERIES K_A6C_NPT47L NPT SERIES K_A6C_NPT47L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER

More information

CPF PRODUCT DESCRIPTION

CPF PRODUCT DESCRIPTION CPF 175 340 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPF 175-340 compressor is a quiet, complete and ready-for-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO

More information

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS Installation, Operation and Maintenance Manual MODELS DAP500, DAP1000 & DAP2000 Model Number

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L GUARDIAN SERIES K2NA6C14DP50L Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ

More information

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850 Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850 Table of Contents Troubleshooting Diagnostic Codes... 2 E1, E2... 2 E3, E4... 3 E5, E6 & E7... 7 E8... 8 E9 9 Verifying Capacity... 10 Water

More information

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WWW.BREEZAIRE.COM WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling

More information

B10TVSD-II & B10TDVSD-II Rotary Screw Air Compressor Units Installation And Start-up Data

B10TVSD-II & B10TDVSD-II Rotary Screw Air Compressor Units Installation And Start-up Data B10TVSD-II & B10TDVSD-II Rotary Screw Air Compressor Units - - - Installation And Start-up Data Contents: Page: Quick Start... 2 Safety Precautions 4 Unpacking and Inspection... 5 Installation Mechanical.

More information

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm Refrigerated Dryers Cycling; Non-Cycling; High Pressure; High Temperature 20 30,000 scfm The Importance of Clean, Dry Compressed Air How much water is too much? Any amount of water is too much. Water jeopardizes

More information

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions

More information

GENESIS AIR CONDITIONERS

GENESIS AIR CONDITIONERS INSTRUCTION MANUAL FOR: GENESIS AIR CONDITIONERS McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 W W W. M C L E A N T H E R M A L. C O M 1 10-1008-170

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm Refrigerated Dryers Cycling; Non-Cycling; High Pressure; High Temperature 20 30,000 scfm The Importance of Clean, Dry Compressed Air How much water is too much? Any amount of water is too much. Water jeopardizes

More information

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...

More information

CWS AIR-CONDITIONERS

CWS AIR-CONDITIONERS CWS AIR-CONDITIONERS MODUL & MODUL XL INSTALLATION, OPERATION AND MAINTENANCE MANUAL MODUL_GB_2007.doc page 1 of 28 10/04/07 CWS air-conditioners 1 - Installation CONTENTS 1 Installation 2 Commissioning

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP More Than 145 Years of Compressed Air Innovation Ingersoll Rand introduced its first air compressor in 1872. Over the next 145 years, we have continued to

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Utopian Split A/C. Thank you for purchasing this quality Split A/C system! Utopian Split A/C Thank you for purchasing this quality Split A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any operation

More information

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D User Manual Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D Commercial Reach-In Freezers: FZ-1D, FZ-2D This manual contains important information about your new Admiral Craft refrigerated unit.

More information

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com

More information

RPI Industries, Inc.

RPI Industries, Inc. IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales CONFECTIONERY USE & SERVICE MANUAL WARRANTY INFORMATION For Models Bradford

More information

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10

More information

KM-630MAH KM-630MWH KM-630MRH

KM-630MAH KM-630MWH KM-630MRH NO.: ISSUED: 73114 JUNE 23, 2004 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-630MAH KM-630MWH KM-630MRH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain this

More information

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS TABLE OF CONTENTS I. General Information.................................................. 2 II. Standard Ceiling Plenum

More information

AIR CONDITIONER OPERATOR'S MANUAL

AIR CONDITIONER OPERATOR'S MANUAL Model KAC4P777R AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT INSTALLATION INSTRUCTIONS (DOCUMENT NUMBER 900-090-00) SHIPPED WITH THE

More information

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel Model Number: JC-88 MODEL# : BR-125SD Instruction Manual Thank you for your purchase of this WHYNTER product. Please read this Instruction

More information

ACT Cartridge Dust Collector

ACT Cartridge Dust Collector IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions

More information

REFRIGERATED AIR DRYERS

REFRIGERATED AIR DRYERS QUINcy qpnc series NON-CYCLING Quincy QRHT Series High temp REFRIGERATED AIR DRYERS Non-cycling designs for maximum system efficiency NON-CYCLING DRYERS 10 to 3000 CFM Quincy refrigerated air dryers are

More information

Nirvana Cycling Refrigerated Dryers

Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Ingersoll Rand s Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class: reliability that you can

More information

ACT REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air - Water Cooled CANADA 7425MUM182_EN_

ACT REFRIGERATING AIR DRYER USER S MAINTENANCE AND SPARE PARTS MANUAL. Air - Water Cooled CANADA 7425MUM182_EN_ ACT 20-500 REFRIGERATING AIR DRYER EN USER S MAINTENANCE AND SPARE PARTS MANUAL Air - Water Cooled 7425MUM182_EN_2012-02 CANADA -EN EN- ACT 20-500 Dear Customer, thank you for choosing our product. In

More information

EN Installation and Operation Manual

EN Installation and Operation Manual EN Installation and Operation Manual Heatless Regenerated Dryer DRYPOINT XC Premium Series XCp models 80 to 800 with BEKOTOUCH Controller READ MANUAL FIRST BEFORE INSTALLATION AND OPERATION Contents 1.

More information

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US Please read this manual carefully before use and keep in a safe place for future reference. IMPORTANT SAFETY INSTRUCTIONS WARNING To

More information

DRIZAIR 110 REFRIGERANT DEHUMIDIFIER

DRIZAIR 110 REFRIGERANT DEHUMIDIFIER OWNER'S MANUAL WARRANTY OPERATING INSTRUCTIONS SAFETY MAINTENANCE SPECIFICATIONS PARTS LIST DRIZAIR 110 REFRIGERANT DEHUMIDIFIER This manual has important safety warnings and operating information. Please

More information

DGH Series Global Air Treatment

DGH Series Global Air Treatment DGH Series Global Air Treatment 2 DGH Desiccant Dryers Customizable Performance Gardner Denver DGH Series Heatless Desiccant Dryers were designed to help you meet your goals. Customizable performance technology

More information

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W Energy- Saving Mode Window AC 12000BTU MODEL: 12000BTU 11.2 Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers Refrigerated Air Dryers Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. 107 W. Main St. Worthington, Pennsylvania 16262 Phone: (724) 297 3416

More information

Delta P Control. Installation and Operation Manual. Installation, Operation, and Service Information. English Master Language

Delta P Control. Installation and Operation Manual. Installation, Operation, and Service Information. English Master Language Delta P Control Installation and Operation Manual Installation, Operation, and Service Information This manual is property of the owner. Leave with the collector when set-up and start-up are complete.

More information

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify

More information

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U INSTRUCTION MANUAL UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U To ensure proper use of this appliance and your safety, please read the following instructions completely before

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series High-Capacity Cycling Refrigerated Compressed Air Dryer RTM Series ié~çáåö íüé t~ó áå ^áê mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Aircel has built

More information

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT GREAT LAKES AIR ANDARD ELECTRONIC DRAIN STANDARD ELECTRONIC 5 -YEAR WARRANTY 35-39 F PRESSURE DEWPOIN SS EXPANSION VALVE STANDARD ELECTRONIC DRAIN 35-39 F PRESSURE DEWPOINT GTX Series Thermal Xchange Cycling

More information

16 OUTDOOR MISTING FAN

16 OUTDOOR MISTING FAN 16 OUTDOOR MISTING FAN Model: SF-1670M READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USE IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to

More information

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency. Energy saving refrigeration dryers 10-1000 SCFM Purifying your compressed air, increasing your efficiency. Refrigeration dryers with Energy Saving Pulse Technology and Thermal Mass With the introduction

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series 7.5 AND 10 TON HEAT PUMPS 7.5 TO 10 TONS 506148 01 10/2011 Supersedes 06/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean

More information

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax: INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Vandal Resistant Refrigerated Universal Bi-Level AquaAccess Barrier Free, Wall Mounted Water Cooler OR Alternate Configuration A112408B/S-VR-UBL TECHNICAL

More information

Installation and Operation Guide For

Installation and Operation Guide For Installation and Operation Guide For S23R, S49R, S23F, S49F S23RG, S49RG Refrigerator S23R S49R Freezer S23F S49F Refrigerator S23RG S49RG CONTENTS 1. SPECIFICATIONS 2. SERIAL

More information

Owner s Manual Models: TC-12B - TC-60B4, Digital Thermostat

Owner s Manual Models: TC-12B - TC-60B4, Digital Thermostat Owner s Manual Models: TC-12B - TC-60B4, Digital Thermostat 1-800-836-7432 Warning! Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Please read

More information

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS ENERGY CONSUMPTION HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS Introduction Those in charge of specifying and purchasing equipment for industrial compressed air systems have many

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW22AL 387030005 AW28AL 387030006 AW38AL 387030007 AW42AL 387030094 0.8180.467.0

More information

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how

More information

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how to install,

More information

SH3020 USER INSTRUCTIONS

SH3020 USER INSTRUCTIONS DEHUMIDIFIER SH3020 USER INSTRUCTIONS GUARANTEE This product is guaranteed for 2 years from the date of original purchase. If any defect arises due to faulty materials or workmanship, the unit will, either

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

Service Manual Models CPH2 & CPH3

Service Manual Models CPH2 & CPH3 Plate Heater Service Manual Models CPH2 & CPH3 888-892-2213 alluserv.com Plate Heater Service Manual Models CPH2 & CPH3 Table of Contents Introduction...................................................2

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS CAUTION RISK OF INJURY! READ MANUAL BEFORE OPERATING! This manual is an important part of the Corona Discharge Ozone Generator and must remain

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure

More information

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04 OWNERS MANUAL Installation Operation Specifications Features Maintenance Warranty 65-00087-004 REV 02_04 FA SP-ENG OM - 02_04 INTRODUCTION CONTENTS Congratulations, you have purchased one of the most effective,

More information

Glass Door Undercounter and Countertop Freezers

Glass Door Undercounter and Countertop Freezers To better help you obtain assistance or service should you ever need it, write down the following information about the product. This information is on the identification label located on the left hand

More information