1 boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 00 to 0kW. DHW output to,00 litres per hour.

2 Where quality and reliability cannot be compromised, select the space-saving Cosmo Combination. With over fifty years experience, Hoval can supply a combination boiler to suit every application.

3 General The Hoval Cosmo Combination boiler couples the tried and tested technology of the Cosmo boiler with that of the Hoval CT-plus and Modul-plus (A type) calorifiers. Mounted above the boiler, the calorifier combines with the boiler to provide a fully integrated package. This includes DHW temperature control, pressure-jet burner suitable for firing on gas, oil or dual fuel and optional primary loading pump. Application Its compact design and flexibility are fundamental to the Cosmo Combination boiler, which is ideal for plantrooms with limited floor space or where there is a policy of decentralising boiler plant to point of use. But first and foremost the combination succeeds where there are peak demands for DHW e.g. hotels, leisure centres, canteens and military accommodation. It is here that the Cosmo Combination comes into its own, offering low cost installation in conjunction with optimum energy efficiency. Mix & Match Tailored, special combination packages, as for example, in the case of dedicated DHW generation, are available through Hoval Mix & Match packages. For mixed heating and DHW applications, please refer to technical data. Secondary outlet Primary inlet Design Both the Modul-plus and CT-plus calorifiers used in the construction of the Cosmo-Combination have high grade stainless steel inner vessel(s) with a rippled wall, surrounded by a mild steel primary water jacket. The CT-plus has one single cylinder whereas the Modul-plus is made from a series of interconnected cylinders. The cylinders are wrapped in an insulation blanket within the Cosmo Combination casing. For DHW generation, the Hoval patented rippled heat transfer surface:- gives rapid regeneration of secondary water tempertures even after complete draw off. provides an extended heat transfer surface within the compact cylinder. creates turbulence on both the primary and secondary water sides to enhance heat transfer and prevents dead legs. provides a low intensity, large heat transfer surface, which reduces scale formation. The inside wall self descales due to the expansion and contraction movement of the rippled surface. strengthens the inner cylinder, thus allowing it to run on unvented systems at pressures up to bar g as standard & 0 bar g for high pressure models. Modul-plus cylinder Primary outlet Secondary inlet Optional A listed primary pumps Energy efficient A listed primary pumps are available on request. A rated pumps consume up to % less energy than traditional pumps. Boiler Key Benefits No minimum water flow rate is required due to a large boiler water content. Unique third pass tube design for improved heat transfer rate on boiler. Boiler quality steel chamber and shell construction with heavy grade tubes. Standing losses typically 0.%. Hinged boiler door and bolt-on smoke box provides easy access for cleaning and maintenance. Suitable for use with a range of matched burners for firing on gas, oil or dual fuel. Extremely reliable offering both high efficiency performance together with low NOx emissions. Operating temperatures up to 00 C. Working pressure bar as standard. bar model available on request (only with A type calorifiers). Efficiency to 9% net. Controls All Cosmo Combinations are supplied with an integral control panel, which is mounted on the front of the unit where practical. Side-mounted control panels are avalable on request. Optional TopTronic control Alternatively Hoval TopTronic controller(s) can be specified, providing a simple user friendly operating platform that controls individual heating and hot water systems and optimises energy consumption. (See Separate leaflet for more details).

4 The space-saving Hoval Cosmo Combination offers an ideal solution to meet the heating and hot water demands of any hotel, sports centre, school, hospital or care home. Insulation litres DHW storage in each modul cylinder. High grade stainless steel rippled heat transfer surface Contra-flow of primary and secondary water for increased heat transfer. Carbon steel primary water jacket surrounding the DHW cylinder Each cylinder has an inspection opening for easy cleaning. Rotating turbulent flow stream increases heat transfer Generous water volume permits no minimum water flow rate Combustion chamber sight glass Pressure jet burner suitable for gas, oil or dual fuel. Large combustion chamber helps reduce NOx emissions Dimpled tubes reduce laminar flow and increase efficiency Fully insulated combustion chamber for minimal standing losses Doors can be hinged on either side. Picture shows Cosmo boiler with Modul-plus (A) calorifier. Hot water on tap. From large houses to luxury hotels the Cosmo Combination can efficiently produce both domestic hot water and heating from one space saving unit. With over fifty years experience producing the calorifiers and combination boilers, during which time Hoval have refined the design to make it extremely reliable and easy to maintain. The design is significantly more resistant to scaling than conventional calorifiers due to the large heat transfer surface area and subsequently low intensity across it. Helps protect against legionella or bacteria. All Cosmo Combination calorifiers work on the primary water jacket principle. Whereby the stainless steel cylinder containing the domestic hot water is surrounded by hot primary water from the Cosmo boiler. Thus, the temperatures at the inner wall of the stainless steel cylinder are only marginally lower than the primary medium temperature. So as the kill-time for micro-organism above 0 o C is instantaneous, the cultivation of a bio-film in which legionella or bacteria growth can occur is significantly reduced. With full turbulant flow and low hydraulic resistance through the unit there are no dead legs, this makes the Cosmo Combination the ideal solution for hospitals, homes for the aged, schools and health resorts, where the very highest levels of domestic hot water hygiene are required. Design. Central to the calorifier design is the rippled stainless steel DHW cylinder. The rippled cylinder increases heat transfer across the primary and secondary mediums. It also adds strength, so with a maximum secondary working pressure of bar g (as standard) makes it ideal for unvented DHW systems. In addition as the domestic hot water passes through the stainless steel cylinder the rippled surface promotes turbulence and so naturally destratifies the hot water (no dead legs). The low hydraulic resistance through both the primary and secondary sides of the calorifier also allows the water to circulate through the unit more freely.

5 Technical Data Cosmo Combination Cosmo Combination Boiler Model () Nominal output () kw Minimum output kw Boiler input at nominal output kw Boiler input at minimum output kw Maximum boiler operating temperature C Minimum return temperature (oil/gas) C 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ Minimum flue gas temperature C Maximum working pressure / test pressure () bar /9 /9 /9 /9 /9 /9 /9 /9 /9 /9 /9 /9 /9 Boiler efficiency net () at 00%PN % at 0%PN % Standing losses qb at 0 C (9) Watt Insulation thickness mm Fuel Consumption at nominal output Nat Gas () m /hr seconds oil () litres/hr Hydraulic resistance through the boiler () z-factor Hydraulic resistance with K T m bar Hydraulic resistance with 0 K T m bar Water Flow rate with K T m / h Water Flow rate with 0 K T m / h Boiler water content litres Dry Weight (without burner) () kg Connections: Flow/Return # PN DN DN DN DN0 DN0 DN0 DN DN DN DN0 DN0 DN0 DN0 Flue (o/dia) mm Cosmo Combination Calorifier Model () CT0 CT0 CT0 A A A A Water content Secondary (DHW) litres Primary (calorifier only) litres Max working pressure Secondary (DHW) bar g Primary () bar g... Test pressure Secondary (DHW) bar g Primary () bar g DHW output () Peak (litres/0 mins) Continuous (litres/ hour) Calorifier primary load () kw Primary flow rate l/s Primary resistance mbar Secondary flow rate l/s Secondary resistance mbar Calorifier Weight Dry () kg Fully Flooded () kg Calorifier Standing 0 C (9) W 0 0 Maximum chloride content in DHW (0) mg/litre Connections: Primary inlet and outlet # BSP/PN R./ ײ R./ ײ R./ ײ DN0 DN DN DN DHW Cold feed # BSP R./ ײ R./ ײ R./ ײ R ײ R ײ R ײ DN DHW flow # BSP R./ ײ R./ ײ R./ ײ R ײ R ײ R ײ DN DHW return BSP R./ ײ R./ ײ R./ ײ R ײ R ײ R ײ R ײ # All flanges on bar version will be PN. (Only suitable for high pressure A type calorifiers). () All boiler / calorifier combinations are available except where the calorifier primary load exceeds the nominal boiler output. () Refers to all standard Cosmo boilers, (maximum primary pressure is governed by the calorifier), a higher pressure version is available on request only with the A type calorifier, ( bar maximum primary operating pressure / bar test and 0 bar maximum secondary operating pressure bar test). () Boiler efficiencies at 00% load are based on a mean operating temperature of 0 o C. At 0%, efficiencies are based on a mean temperature of 0 o C. () Based on gross CV. MJ/m. () Hydraulic resistance (mbar) = (Flow rate (m /h)) x z () Dry weights based on the bar boiler, to calculate the weight of an bar version add 0%. For total dry weight add boiler to calorifier weight. () For total standing losses add boiler standing losses to that of the calorifier. (9) Chloride content up to 00mg/litre acceptable with the use of sacrificial anodes. (0) Outputs based on o C primary inlet, 0 o C cold feed and 0 o C DHW flow temps. () Based on gross CV. MJ/kg and specific gravity 0.. Model Example. The Model for the combination with a Cosmo and a CT0 is: Cosmo/CT0. Please refer to selection table for matching options. Model Example. The Model for the combination with a Cosmo 0 and a A is: Cosmo0/A. Please refer to selection table for matching options.

6 Dimensions and Technical Information Cosmo Combination boiler (models -0 with C type calorifiers) Where calorifier is longer than boiler, it will overhang at the front. 0 Burner & Flue C L d 0 a (calorifier) a (boiler) i 00 d k j b Calorifier primary pump, stool piece and pipework optional Left or right hand side mounted control panel optional. 0 c* 9 0 c* Boiler & calorifier are the same width. A drain valve should be installed in the DHW cold feed pipework between the unit and the isolation valve to facilitate draining down. For model options please refer to the separate selection table. e f h 0 g g 0 Flow Return Hydraulic drain Flue outlet Condensate drain R/ ײ Note: Automatic air vent G/ ײ Std control panel position Plugged vent connection 9. DHW flow 0. DHW cold feed. DHW return. Calorifier primary inlet. Calorifier primary outlet. Primary vent. Primary pump (Optional). Non-return valve (Optional). Flexible pipework (Optional). Flow/return stool pieces (Optional) 0. DHW thermostat/thermometer box. T&P valve connection (unvented) The installer must fit a safety valve in the flow pipework before any isolation valve. The installer must ensure the automatic air vent () is fitted. The installer must also ensure the condensate drain connection () is piped to drain via a drain trap to prevent flue gases escaping. Do not fit an isolation valve in this pipework. It is recommended that a DHW drain is fitted to the cold feed adjacent to the calorifier to facilitate draining the calorifier. A single phase 0V supply is required for the control panel operation. Single phase burners and pumps are electrically supplied via the control panel. Three phase burners and pumps require a seperate three phase isolated supply (by the installer) direct to the burner / pump. The supply to the burner should be flexible to allow for boiler / burner door opening. In this case control cables fitted with wieland plug/sockets will still run between the control panel and the burner. Cosmo Boiler Dimensions: a (boiler) (mm) b (mm) c (mm) d (mm) e (mm) f (mm) 0 0 g (mm) h (mm) i (mm) j (mm) Cosmo Boiler connections: Flow (PN) DN DN DN DN0 DN0 DN0 DN DN DN DN0 DN0 DN0 DN0 Return (PN) DN DN DN DN0 DN0 DN0 DN DN DN DN0 DN0 DN0 DN0 Drain (BSP) G./ ײ G./ ײ G./ ײ G./ ײ G./ ײ G./ ײ G ײ G ײ G ײ G ײ G ײ G ײ G ײ Flue O/Dia (mm) C type Calorifier dimensions: CT0 CT0 CT0 a (calorifier) (mm) k (mm) C type Calorifier connections: Primary inlet & outlet (BSP) R./ ײ R./ ײ R./ ײ DHW flow (BSP) R./ ײ R./ ײ R./ ײ DHW cold feed (BSP) R./ ײ R./ ײ R./ ײ DHW return (BSP) R ײ R ײ R ײ

7 Dimensions and Technical Information Cosmo Combination boiler (models 0-0 with A-type calorifiers) a (calorifier) Calorifier primary pump, stool piece and pipework optional A, A & A A c c 0 0 Where calorifier is longer than boiler, it will overhang at the front. k 9b 9a Burner & Flue C L d a (boiler) i 00 d j b e f h 0 g g 0 g g 0 Flow Return Hydraulic drain Flue outlet Condensate drain R/ ײ Note: Automatic air vent G/ ײ Std control panel position Plugged vent connection 9. DHW flow, (9a A & A, 9b A) 0. DHW cold feed. DHW return. Calorifier primary inlet. Calorifier primary outlet. Primary vent. Primary pump (Optional). Non-return valve (Optional). Flexible pipework (Optional). Flow/return stool pieces (Optional) 0. DHW thermostat/thermometer box. T&P valve connection(s) (unvented) The installer must fit a safety valve in the flow pipework before any isolation valve. For Model options please refer to separate selection table. The installer must ensure the automatic air vent () is fitted. The installer must also ensure the condensate drain connection () is piped to drain via a drain trap to prevent flue gases escaping. Do not fit an isolation valve in this pipework. It is recommended that a DHW drain is fitted to the cold feed adjacent to the calorifier to facilitate draining the calorifier. # All flanged connections PN as standard, PN on bar version. A single phase 0V supply is required for the control panel operation. Single phase burners and pumps are electrically supplied via the control panel. Three phase burners and pumps require a seperate three phase isolated supply (by the installer) direct to the burner / pump. The supply to the burner should be flexible to allow for boiler / burner door opening. In this case control cables fitted with wieland plug/sockets will still run between the control panel and the burner. Cosmo Boiler Dimensions: a (boiler) (mm) b (mm) c (mm) d (mm) e (mm) f (mm) 0 g (mm) h (mm) i (mm) j (mm) Cosmo Boiler connections: Flow (PN) # DN DN DN0 DN0 DN0 DN DN DN DN0 DN0 DN0 DN0 Return (PN) # DN DN DN0 DN0 DN0 DN DN DN DN0 DN0 DN0 DN0 Drain (BSP) G./ ײ G./ ײ G./ ײ G./ ײ G./ ײ G ײ G ײ G ײ G ײ G ײ G ײ G ײ Flue O/Dia (mm) A type Calorifier dimensions: A A A A a (calorifier) (mm) k (mm) A type Calorifier connections: Primary inlet & outlet (PN) # DN0 DN DN DN DHW flow (BSP/PN) # R ײ R ײ R ײ DN DHW cold feed (BSP/PN) # R ײ R ײ R ײ DN DHW return (BSP) R ײ R ײ R ײ R ײ

8 Product Specification Selection chart Cosmo Boiler: Calorifier CT0 CT0 CT0 A A A A The above table indicates the boiler / calorifier combinations available. Standard Specification The Cosmo Combination is supplied with the following as standard: Cosmo boiler complete with rear flow and return, flue, hydraulic and condensate drain connections. Right hand hinged (left hand optional) boiler door with sight glass. Bolt-on smoke box with clean out door. Open vented CT or A type calorifier. Mineral wool insulation matress. Steel casings finished in red and orange. Control panel containing: Burner control thermostat, Burner high/low thermostat, On/off switch, Excess temperature, burner run, burner lockout, and high fire indicators, Boiler thermometer. Calorifier control stat and thermometer box. Fully matched high/low pressure jet burner with wiring harness. Tommy bar. Cleaning brush with rod. Installation, Operation and Maintenance instructions. Optional Specification The following options are available on request: Modulating burner with controller in boiler control panel. Modulation of burner via 0-0 volt signal. Calorifier immersion heater. up to No..kW per modul cylinder. kw, 9kW and kw on CT calorifiers. Separate isolated power supply by installer. Calorifier primary loading pump with non return valve, isolation valves, primary -port valve (only on unvented DHW systems), and pump starter panel (if required), all for connection from main system header(s) by others. Calorifier primary loading pump and pipework kit for fitting to boiler by installer, and comprising: Primary inline circulating pump, Non return valve, Pump isolation valves, Boiler flow and return stool pieces, Flexibles (where appropriate), Pump starter panel (where required). Primary -port valve (unvented DHW systems only). Optional Specification Continued... Boiler safety valve, altitude gauge, drain valve, gas boosters and shrouds. Calorifier high temperature limit thermostat (hand reset type). Volt-free contacts for boiler run, burner lock out, and boiler high temperature lockout signals. Volt-free contact for calorifier high temperature lockout signal. Calorifier suitable for unvented system and complete with temperature and pressure relief valve connection(s), calorifier hand reset limit thermostat, temperature and pressure relief valve(s). Unvented system kit comprising: Strainer, Pressure reducing valve with gauge, Double check valve, Expansion vessel, Combined lock shield / drain valve, Expansion relief valve with tundish. Calorifier magnesium anode. Calorifier primary pump and pipework (Optional) (open vented units detailed) Cosmo / CT0-CT0 Cosmo / A, A & A Cosmo / A. Primary loading pump.. Non-return valve.. Pump isolation valves.. Flexible hose (where practical).. Rigid pipework.. Boiler return stool piece,. Boiler flow stool piece.. Pump starter panel. Note. All items are sent as a kit for the installer to assemble. Wiring to and from the primary loading pump and -port valve (where required) is by the installer. All ph pumps and large ph pumps will require a pump starter. The pump starter is supplied in a small enclosure for mounting and site wiring by the installer.

9 System Design Primary systems Integral primary pump & pipework The Cosmo Combination can be supplied complete with an optional fully matched calorifier primary loading pump, valves and pipework kit for site assembly and wiring by the installer. Calorifier primary loading pump and pipework. Vented Unvented Primary system key.. Boiler flow. Boiler return. Primary inlet. Primary outlet. Check valve. Isolation valve Secondary systems The Cosmo Combination can be used on both vented and unvented systems. The installer must fit a secondary drain connection in the cold feed between the unit and the isolation For applications where some degree of standby is necessary, the installer should consider either fitting an immersion heater or where DHW outputs are crucial, two or more units should be installed as shown on the right. These schematics are for guidance only and do not constitute system design.. Primary pump. -Port valve 9. System pump(s) 0. -Port valve. Heating circuits Summer Operation The use of boiler plant for all year round operation makes best use of capital investment. Using a combination boiler, illustrates this point with the close matching of the boiler output to the calorifier output. In the summer, for example, the DHW load (and possibly a small heating load) will be required. Where two or more combination boilers are installed it is therefore desirable for all calorifiers to be served by a matching boiler output, usually from just one boiler. The above can be achieved using one of the following typical schemes: Primary connections via low loss header. () -port valve on unvented calorifiers 9 only. Heating the calorifier primaries via a low loss header is one way of providing both heating and DHW standby. If no heating is required during the summer, isolate the header from the heating system(s). Twin primary pumps () available on request. Primary connections via main flow and return headers. Connecting the calorifier primary pumps and pipework to the main flow and return headers. If no heating is required during the summer, isolate the flow and return headers from the heating system. Primary connections via main flow and return headers. A -way valve can be used to control the flow of primary water to the calorifier. # Where the main heating pump has sufficient head this can be used to charge the calorifier, otherwise a separate pump () is required. Optional -port valve () mandatory on unvented DHW systems. valve. An anti-thermal dip should be fitted in the cold feed to prevent natural circulation back up the cold feed pipe. This pipe should not be oversized as this may cause thermal circulation. 9 0 () -port valve on unvented calorifiers only. # See note below () -port valve on unvented calorifiers only. 9 Secondary connections Unvented system. Secondary connections Vented system.. DHW flow. DHW return. DHW cold feed. Cold water mains. Strainer. Pressure reducing valve. Double check valve. Lock shield valve 9. Drain 0. Expansion vessel. Isolation valve. Expansion relief valve. T&P relief valve. Secondary recirculating pump.. Anti-thermal dip Cosmo / CT Combination shown.. DHW flow. DHW return. DHW cold feed. Cold water mains. F & E tank. Isolation valve. Secondary recirculating pump. Vent pipe 9. Anti-thermal dip 0. Drain Cosmo / CT Combination shown. 9 0

10 Installation Information Delivery and assembly All Cosmo combination boilers are delivered with calorifier, burner, insulation, casings, control panel and (where ordered) pump kits packed separately for fitting by the installer. Any ancilliary items such as safety valves, immersion heaters, altitude gauges, drain valves, gas boosters etc will also be supplied separately for fitting and wiring (where appropriate) by the installer. As standard, the boiler and calorifier will be supplied as two separate units for the installer the mount on site. It may be possible to do this in our factory prior to delivery, please consult Hoval Technical to discuss. Before mounting the burner, the front casing must be fitted. Likewise before connecting the flue, the rear casing must be fitted. Boiler shipment dimensions and weights H W L Lifting shackle Cosmo Boiler Model Boiler Dimensions: L (mm) W (mm) H (mm) Weight: (kg) 0 0 Casings Box Dimensions: L (mm) W (mm) H (mm) Weight (kg) Calorifier Shipment dimensions and weights C type Calorifiers Lifting eye A type Calorifiers H H Lifting lugs W L W L Cosmo Calorifier Model CT0 CT0 CT0 A A A A Calorifier Dimensions: L (mm) W (mm) = boiler width = boiler width = boiler width = boiler width H (mm) Weight: (max) (kg) Casings Box Dimensions: L (mm) W (mm) H (mm) Weight (max) (kg)

11 Installation Information K Minimum Access L W T Plantroom Layout. Wherever possible, space should be left around the boiler to enable all parts to be examined and the cubicle casings to be fi tted or removed easily. Front clearance: Space for the burner and the servicing of the equipment, must be accommodated. Ideally, front clearance should equate to the length of the boiler. This will permit the cleaning and removal of boiler tubes and also the extraction of DHW immersion heaters and where required sacifi cial anodes. The installer is advised to avoid creating obstructions which may hinder opening the boiler door, or the fi tting of an acoustic shroud. These obstructions include; other plant, extended boiler plinths, extensive gas pipework, and rigid oil lines / burner power supplies. Boiler plinth should not obstruct the shroud. K = (W T) x L T = (W K) x L T = Door opening K = Corridor width W = Boiler width L = Boiler length Hoval recommend the boiler plinth does not project beyond the front of the boiler as this will prevent a wheel-over type shroud from encapsulating the burner. Also, in some circumstances a plinth may be necessary to increase the firing height of the boiler to accomodate a particular burner. The installer must avoid, wherever practicable, the fi tting of pipework within the swing of the boiler door. If this is not possible, a removeable stool piece with a shut off valve upstream must be fi tted. Side Clearance: Generally a minimum clearance of 00mm is required at the side of the boiler to fi t and remove the side casings. Space to one side of the boiler is required to swing the boiler door with the burner fi tted, (standard to the right, optional to left), whereby when the door is open 90 o, the length of the burner+0mm will be at the side of the boiler. Normally the same access for the burner swing can also be Typical Plan View If ph burners are fi tted, the installer should ensure that the power supply to the burner is fl exible to allow the boiler door to fully open. used for getting to the back of the boiler. Where gas burners are fi tted consideration should be given to the gas train (and booster if specifi ed). Normally the gas pipe mains are run either from high or low level. In both cases an elbow has to be fi tted off the gas train to connect back to the header. Where gas trains fall within the width of the boiler this elbow has to be taken into account. Rear clearance: is required for the fl ue and system connections and access to the cleaning door. Consideration for the fl ue and calorifi er connections should be made to ensure these do not clash. Top clearance: is required above the unit to fit safety valves, automatic air vents and to access the calorifi er. Shorter clearances are possible subject to cleaning methods and plantroom layout. Please consult Hoval technical. Unvented systems: Where the DHW system is unvented, an unvented system kit must be installed. Unvented systems can be fed either directly from the mains or through a cold water booster set. Both require an unvented system kit. Hoval s standard kits are sized to suit the calorifi er. Where balanced hot and cold water services are required, valves sizes may have to be increased. In addition to the unvented system kit, a hand reset limit stat and primary -port valve must be fi tted. Mains fed unvented system kit: With a mains fed unvented system kit Hoval supply the following:- - Strainer. - Pressure reducing valve with gauge. - Double check valve. - Expansion vessel with combined lock shield / drain valve. - Expansion relief valve with tundish. - Temperature and pressure relief valve. Boosted unvented system kit: With a boosted unvented system kit Hoval supply the following:- - Double check valve. - Expansion vessel with combined lock shield / drain valve. - Expansion relief valve with tundish. - Temperature and pressure relief valve. - Pressure reducing valve with gauge (not necessary on systems with inverter controlled booster sets or where this is part of the booster package). Space should be allocated for siting the expansion vessel off the cold feed pipework. It is recommended that a lock shield / drain valve should be installed in the leg to the expansion vessel. The pipework to the expansion vessel should be kept to a minimum to avoid an unnecessary dead-leg. Common unvented system kit: Where two or more Cosmo Combinations are installed it is possible to fi t a common unvented system kit in the main cold feed prior to teeing off to the calorifi ers. The following items are sized to suit the output of all the units and the total system volume including the cylinder volume: - Strainer, - Pressure reducing valve with gauge, - Double check valve, - Expansion vessel with combined lock shield / drain valve. The following safety valves must be fi tted to each calorifi er: - Expansion relief valve and tundish - Temperature and pressure relief valve(s). There should be no means of isolating the expansion relief valve and the temperature and pressure relief valve(s) from the calorifi er.

12 Other associated products Uno- The Uno- boiler couples high efficiency with low NOx emissions. These dual goals are achieved with the special -pass design which incorporates the unique Hoval thermolytic heat exchanger. Available as heating only units or with a calorifier as a combination unit, with ratings between 0 and 0 kw and DHW up to 0 litres per hour. Plate heat exchangers At the heart of Hoval s plate heat heat exchanger programme is the Hoval UltraPlate, which is available in two basic models; the UP-g gasketted and the UP-b brazed plate heat exchanger. The UltraFlow plate heat exchanger packages and UltraStore plate heat exchanger / buffer vessel packages embrace the advantages of the UltraPlate and provide the installer with an economic solution to meet their DHW needs. Cosmo heating only and heatpack The Cosmo heating only boilers are available with outputs up to 00kW and heatpack boilers up to 900kW. Suitable for firing on gas, oil and dual fuel with a fully matched and packaged pressure jet burner. The Cosmo-plus boiler combines with a suitable TC-AF ThermoCondensor for additional efficiency gains PressVal Micron The PressVal Micron range of pressurization units are compact microprocessor controlled units. Covering all system ouputs from small commercial heating and chilled water systems, through to the very largest district heating schemes. Both single and twin pump units are available in wall hung, free standing, skid mounted, or cabinet housed configuations. Volt free contacts for BMS interface provide as standard. April 00 By Appointment to Her Majesty the Queen Boiler Manufacturers & Engineers Hoval Ltd Newark. Conservation of energy - protection of the environment Hoval follows a policy of continued improvement and reserves the right to change specifications without notice.

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW. Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to bar. Heatpack boilers to 2900kW. Whether your application is for single, multiple or space saving heatpack boilers, Hoval always

More information

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar Hoval SR-plus heating boilers Outputs from 30 to 4000kW Working pressures to 8 bar ...built in the UK where high quality and reliability have been a way of life for generations. Hoval SR-plus Simplicity

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame

More information

High-output calorifier Modul-plus

High-output calorifier Modul-plus High-output calorifier Modul-plus Favourite choice für refined domestic hot water convenience. 1 Modul-plus. Advantages at a glance It is the favourite choice for refined hot water convenience in renowned

More information

Hoval Solar Equipment. The complete solution for domestic hot water, space heating support and swimming pool heating.

Hoval Solar Equipment. The complete solution for domestic hot water, space heating support and swimming pool heating. Hoval Solar Equipment. The complete solution for domestic hot water, space heating support and swimming pool heating. Clean and in abundance, in fact several billion years worth still remaining. What better

More information

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment Max-3 plus Steel Shell Boiler Responsibility for energy and environment Output range 420 to 2700 kw Now with new TopTronic E control 1 Why choose Max-3 plus? The Hoval Max-3 plus boiler delivers market-leading

More information

Max-3 Steel Shell Boiler

Max-3 Steel Shell Boiler Max-3 Steel Shell Boiler Responsibility for energy and environment Output range 500 to 3000 kw 1 Why choose Max-3? The Hoval Max-3 boiler delivers market-leading efficiency and cost effective heating performance.

More information

Installation, Operating and Maintenance Manual for F Modul plus Calorifiers

Installation, Operating and Maintenance Manual for F Modul plus Calorifiers Installation, Operating and Maintenance Manual for F Modul plus Calorifiers By Appointment to Her Majesty the Queen Boiler Manufacturers & Engineers Hoval Ltd Newark Revision No.2 Dated: November 2015

More information

Hoval Modul-plus High-output calorifier 640 to 17,500 l/h

Hoval Modul-plus High-output calorifier 640 to 17,500 l/h Hoval Modul-plus High-output calorifier 640 to 17,500 l/h It is the favourite choice for refined hot water convenience in renowned hotels around the world. It easily covers peak outputs in sports facilities

More information

Operating and Installation Instructions for the SR-plus hot water boiler

Operating and Installation Instructions for the SR-plus hot water boiler Operating and Installation Instructions for the SR-plus hot water boiler 0558 4 214 296-04 Issued By TECHNICAL DEPT Dated: May 2016 Approved KS 2 Contents Introduction Gas Safety (Installation and Use)

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I

More information

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary HT-Breeze Instantaneous Water Heaters Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary Contents HT-Breeze pages 2-7 When space is tight and hot water needs

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

Copper-Fin GAS-FIRED WATER HEATERS

Copper-Fin GAS-FIRED WATER HEATERS Copper-Fin GAS-FIRED Lochinvar Corporation has been designing, manufacturing and distributing water heating products in USA since 1919 and has built an enviable reputation for reliable, efficient and cost

More information

S-AF Floor Standing Condensing Boiler kW

S-AF Floor Standing Condensing Boiler kW Clean Heating Naturally STREBEL MMERCIAL BOILERS S-AF Floor Standing Condensing 11-620 Why choose Strebel? S-AF Floor Standing Condensing Strebel Ltd has been supplying, installing and servicing coercial

More information

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw 90 kw Clyde Alkon 90 LP Gas Floor standing condensing boilers Natural Gas 90 kw Contents General information Dimensions and Data Installation requirements Boiler wiring diagram Hydraulic systems Page Fully

More information

Steel Shell Boilers. Max-3 plus kw. Max-3 E & Max-3 condens E kw. CompactGas kw. SR-plus and SR-H plus kw

Steel Shell Boilers. Max-3 plus kw. Max-3 E & Max-3 condens E kw. CompactGas kw. SR-plus and SR-H plus kw Steel Shell Boilers Max-3 plus 420-2700 kw Description 194 Technical Data and Dimensions 198 Typical Hydraulic Schematic 204 Engineering 205 Max-3 E & Max-3 condens E 3000-6839 kw Description 207 Technical

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Euron Compact Wall Mounted as Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Compact, Efficient & Easy to Install & Maintain The Euron range of wall mounted gas fired condensing boilers

More information

Powerstock Storage Tank

Powerstock Storage Tank Powerstock Storage Tank Models ST300, ST500, ST750 & ST1000 INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE. PUBLICATION

More information

Cast Iron Boilers. G Series ( kW)

Cast Iron Boilers. G Series ( kW) Cast Iron Boilers G Series (320-1017kW) Mikrotherm G Series Cast Iron Boilers The Mikrotherm G Series of cast iron sectional boilers offer all the advantages of cast iron durability and longevity coupled

More information

FASTflo. Working towards a cleaner future

FASTflo. Working towards a cleaner future NOW INCLUDES FASTflo PLUS Condensing Model FASTflo Continuous Flow Wall Hung range Balanced Flue Water Heaters Working towards a cleaner future FASTflo Continuous Flow Wall Hung Balanced Flue Water Heaters,

More information

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM S Y S T E M S THE SOURCE OF SUPERIOR SYSTEMS The new Sirrus Radiant wall hung boiler from Sirrus Systems offers good looks, comprehensive safety features and

More information

MAXIMISER Semi-Storage Calorifiers

MAXIMISER Semi-Storage Calorifiers MAXIMISER Semi-Storage Calorifiers Introduction THE RYCROFT MAXIMISER HAS BEEN DEVELOPED TO MEET TODAY S NEED FOR A COMPACT CALORIFIER WHICH WILL RESPOND TO HIGH PEAK LOADS WITH MINIMAL DEMAND FOR BOILER

More information

Broag Pressurisation equipment

Broag Pressurisation equipment Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate

More information

Stored Water District Heating Interface Units. Heat Interface Units

Stored Water District Heating Interface Units. Heat Interface Units Stored Water District Heating Interface Units Heat Interface Units Why choose Elson Elson are a Heatrae Sadia company, the UK s leading manufacturer of hot water solutions utilising thermal store technology

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.

More information

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges 2 The new GT Condenser provides higher efficiencies and low running costs from the Ideal range of pressurised gas boilers. Extracting

More information

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY Hamworthy Fleet Horizontal Floor Standing Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY Fleet H Floor Standing Horizontal Boilers The Fleet range of commercial boilers

More information

BOILER HOUSE PRODUCTS GMS

BOILER HOUSE PRODUCTS GMS GMS BOILER HOUSE PRODUCTS Contents Page 2 Introduction 3 Condensate Pumpsets 6 Blowdown Vessels 8 Boiler Feed Tanks Page 10 Chemical Dosing Pots 11 Vent Heads 11 De-Aerator Heads Introduction to Boiler

More information

LBF RANGE BALANCED FLUED WATER HEATERS

LBF RANGE BALANCED FLUED WATER HEATERS LBF RANGE BALANCED FLUED WATER HEATERS WHY BALANCED FLUE? Lochinvar Corporation has been designing, manufacturing and distributing water heating products in USA since 1919 and has built an enviable reputation

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No. INTRODUCTION The Worcester Greenskies cylinder is a Stainless Steel Unvented Twin Coil Storage vessel specifically designed to be installed in conjunction with the Worcester Greenskies solar package. Should

More information

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers Ethos Range High Efficiency Domestic Boilers Combination Boilers Condensing Combination Boilers Condensing System Boilers From 1994, Mikrofill has been supplying high quality products to the commercial

More information

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW Hamworthy Melbury HE High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners Outputs 530 to 10000 Melbury HE High Efficiency Steel Shell Boilers Gas, Oil, Biofuel or Dual

More information

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES INTRODUCTION The HRSFUNKE Storage Calorifiers offer a high quality solution for domestic hot water (DHW) heating. The standard range is manufactured from

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

Series 1000 & Storage Water Heaters

Series 1000 & Storage Water Heaters Series 1000 & 2000 Storage Water Heaters 1000 Series Vented Water Heaters THE 1000 SERIES WATER HEATER IS SUPPLIED VIA A HEADER TANK AND IS SUITABLE FOR A WIDE RANGE OF COMMERCIAL AND INDUSTRIAL APPLICATIONS

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw atural gas Class D oil Dual Fuel 350 kw to 500 kw Clyde CK40 Cast Iron Boiler Contents Page General information Dimensions 3 Technical data 3 Installation requirements 4 & 5 Boiler control panel 6 Wiring

More information

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi cxi sxi ranges product specifications Product Range Type Model 12 15 18 24 30 38 cxi Combi 24cxi cxi Combi 30cxi cxi Combi 38cxi sxi System 18sxi sxi System 30sxi ppearance esthetic Casing dimensions (h

More information

High-output calorifier Modul-plus

High-output calorifier Modul-plus High-output calorifier Modul-plus Efficient, reliable and economical. The Modul-plus meets the highest standards in terms of continuous hot water production and water hygiene. Modul-plus. Advantages at

More information

Installation and Commissioning Manual

Installation and Commissioning Manual Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12 Contents Page Section Description Page 1... Safety

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Efficient DHW and heating solution with High-output calorifier Modul-plus

Efficient DHW and heating solution with High-output calorifier Modul-plus Efficient DHW and heating solution with High-output calorifier Modul-plus Vaduz, March 2013 Single Boiler with thermostatic control panel Double boiler cascade with digital control panel & Modul-plus Tripple

More information

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier OM004 Installation, Operation and Maintenance Instructions for Electric Storage Calorifier The operating and maintenance instructions contained within this package are for standard electric storage calorifiers

More information

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW Hamworthy Stratton Wall Hung Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW Stratton Wall Hung, Pre-mix Gas Fired Modular Boilers The new Stratton boiler from Hamworthy brings

More information

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09 I N S P I R E D E F F I C I E N C Y Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION Issue 11/09 Technical data Description Extreme 200 Extreme 300 Extreme 500 Weight (empty) kg 63 77

More information

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Gas-Fired Condensing Boilers A Green Start To Space & Water Heating Residential space and water heating boiler solutions with up to 98.7% efficiency and 57.2 to 151.6 MBH inputs. 1 New! Bosch residential

More information

Optimus Gas Absorption Heat Pump

Optimus Gas Absorption Heat Pump Optimus Gas Absorption Heat Pump Low carbon Renewable Technology Gas efficiencies up to 152 gross Low noise levels Low NOx emissions Continuous operation even in defrost mode Low electrical input Indoor

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

Light commercial products. High output boilers Cascade systems

Light commercial products. High output boilers Cascade systems Light commercial products High output boilers Cascade systems District heating FlowSmart Make Alpha your first choice Over the course of nearly 50 years, we have successfully met the heating requirements

More information

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation: A Guide to Commercial Hot Water from Hamworthy Introducing Hamworthy s Product Ranges for Hot Water Generation: Dorchester Direct-Fired Water Heaters Powerstock Indirect-Fired Calorifiers and Tanks Solar

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

Operating and Installation Instructions for the ST-plus hot water boiler

Operating and Installation Instructions for the ST-plus hot water boiler Operating and Installation Instructions for the ST-plus hot water boiler 0088 Issued By TECHNICAL DEPT Dated: Approved KS 2 Table of Contents Contents Introduction Gas Safety (Installation and Use) Regulations

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW Ultramax R600 High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW Delivering excellence with every feature The Ultramax R600 series of boilers is packed with features

More information

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

MAX O GAZ. Condensing water heater TECHNICAL MANUAL MAX O GAZ Condensing water heater TECHNICAL MANUAL 2 CONTENTS THE COMPONENTS OF THE MAX O GAZ.. 1 4 BALANCED FLUE AND CONVENTIONAL FLUE MAX O GAZ FEATURES. 3 6 INSTALLATION OF THE MAX O GAZ... 5 8 STANDARD

More information

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:

More information

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW Hamworthy Stratton Wall Hung Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW Stratton Wall Hung, Pre-mix Gas Fired Modular Boilers The new Stratton boiler from Hamworthy brings

More information

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

FEATURES AND BENEFITS. Up to 109.8% part load efficiency IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single

More information

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater Installation, Maintenance and User Instructions AquaFlo II Issue 3 December 2011 Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater Please leave

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw Subject to modification Contents 1. Important Information 4 1.1. Documentation 4 1.2. Guarantee

More information

Hamworthy Dorchester DR-FC Evo 98%

Hamworthy Dorchester DR-FC Evo 98% 98% Hamworthy Condensing, Room Sealed and Open Flue Direct Gas Fired Storage Water Heaters 30kW to 120kW Natural Gas or LPG Continuous outputs 600l/h to 2400l/h Condensing Direct Gas Fired Storage Water

More information

Pressure Boosting Solutions

Pressure Boosting Solutions GRUNDFOS Water Pressure Boosting Pressure Boosting Solutions 1 GRUNDFOS Water Pressure Boosting WHAT CAN CAUSE LOW WATER PRESSURE? Poor mains pressure Generally due to water companies reducing the supply

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres Hamworthy Powerstock Calorifiers and Storage Tanks Single and Twin s Capacities 160 litres to 995 litres 1 Powerstock Calorifiers and Storage Tanks The efficient generation of hot water for use in commercial

More information

The world s most advanced direct electric water cylinder

The world s most advanced direct electric water cylinder Unvented Hot Water Cylinders Introducing the water cylinder Tried. Tested. Trusted. The world s most advanced direct electric water cylinder Quantum Energy System Unparalleled efficiency Amid a rapidly

More information

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager Hot Water Generation for Commercial and Industrial Applications Paul Marsden Specification Sales Manager Baxi and BDR Thermea Baxi is part of the BDR Thermea Group, a global manufacturer and distributor

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Quantum. Installation, User and Service Manual. Hot Spring

Quantum. Installation, User and Service Manual. Hot Spring Hot Spring Domestic Hot Water Cylinder Storage Capacities 90, 125, 150, 170, 200, 250 and 300 Litres 1 Important - This Manual should be left with the householder after installation Index Section Page

More information

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler Industrial Hot Water Boiler for Oil or Gasfiring Description Industrial Hot Water Boiler The Hoval high output hot water boilers are made of high quality steel and are distinguished by their solid, robust

More information

PROPAK THERMAL. Packaged Plate Heat Exchanger

PROPAK THERMAL. Packaged Plate Heat Exchanger PROPAK THERMAL Packaged Plate Heat Exchanger 2 PROPAK THERMAL Applications Care Homes Student Accommodation Sports & Leisure Hotels Restaurants Accommodation Accommodation Sport & Leisure Care Homes PROPAK

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Hot Water Supply Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong E-mail: cmhui@hku.hk Feb

More information

smart line E SLE

smart line E SLE smart line E SLE 130 300 INDEX INTRODUCTION 1 Intended users of these instructions 1 Warnings 1 1. Operation 2 2. Construction 3 3. Installation Domestic 4 Wiring the thermostats 5 Primary 5 Immersion

More information

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot water supply 4 Stainless steel unvented cylinders Mains

More information

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas DATA SHEET: TDS101.4F 10-625kW R-SERIES YEAR ROUND MAXIMUM CONDENSING BOILER burning diesel oil, kerosene, natural gas or liquid petroleum gas 92% to 99.5% GCV efficiencies throughout the year Modulating,

More information

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet: PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL Operation and Maintenance THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com Introduction The District Pandora Heat Bank provides hot

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Hamworthy. Purewell VariHeat

Hamworthy. Purewell VariHeat up to Seasonal efficiency (gross) Hamworthy Purewell VariHeat High Efficiency, Fully Modulating Boilers Condensing & Non Condensing Cast Iron, Pre-mix, Modular Gas Fired Single Boiler Outputs 65kW to 180kW

More information

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers 21-3500kW Commercial & Industrial Boilers the pressure jet range Contents Introduction

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

INDUSTRIAL / DOMESTIC WATER HEATERS

INDUSTRIAL / DOMESTIC WATER HEATERS INDUSTRIAL / DOMESTIC WATER HEATERS Military hospital Thessaloniki WATER HEATERS ARTEMIS boilers are suitable for use in DOMESTIC, COMMERCIAL and INDUSTRIAL applications for production and storage of the

More information

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW New Twin return connections Wide differential temperature up to Seasonal efficiency (gross) Hamworthy Varmax Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

TopGas Wall Hung Condensing Gas Boiler

TopGas Wall Hung Condensing Gas Boiler TopGas Wall Hung Condensing Gas Boiler Output range 30 to 80 kw Why choose TopGas? TopGas wall-hung boilers offer compact and advanced gas heating technology built to the high quality standards you would

More information

Power Direct Vent PDV(S&T) Models

Power Direct Vent PDV(S&T) Models COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Operating and Installation Instructions for the ST-plus hot water boiler

Operating and Installation Instructions for the ST-plus hot water boiler Operating and Installation Instructions for the ST-plus hot water boiler 0088 Issued By TECHNICAL DEPT Dated: Approved KS 2 Table of Contents Contents Introduction Gas Safety(Installation & Use) Sample

More information

Schuco SS-TC/SC Cylinders

Schuco SS-TC/SC Cylinders Cylinders Installation, User and Service Domestic Hot Water Cylinder Storage Capacities 90, 125, 150, 170, 200, 250 & 300, Litres Important -This should be left with the Cylinder after Installation Schueco

More information

ECONOBOOST EB II & EB III Compact Water Booster

ECONOBOOST EB II & EB III Compact Water Booster ECONOBOOST EB II & EB III Compact Water Booster The Stokvis EB II twin pump & EB III triple pump cold water booster units meet today s need for compact, reliable, high performance equipment with modest

More information