WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.
|
|
- Hannah Gray
- 6 years ago
- Views:
Transcription
1 WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX. 2016
2
3 Energy efficiency classes/general notes Simply individual times over. Energy efficiency classes for heat pumps Y IJA IE IA Energy label The ErP directive (Energy related Products) for room heating/combi heating devices, domestic hot water preparation devices and domestic hot water cylinders comes into force on 26/09/2015. It outlines the design and labelling of energy-efficient products. Consumers will recognise the energy label with the distinctive bars in red, yellow and green, which have been in use for household appliances for years. A similar label will now also be introduced for all heat generators with a nominal heat output of up to 70. From September 2015, this label must be visible for the consumer in advertising, in quotations and on delivery. There are 3 versions of the label: Product label Used for the heat pump in pure heating operation. According to the capacity of the heat generator, an efficiency is shown at a flow temperature of 35 C and 55 C. Combi label Used for heat pumps which are supplied with domestic hot water preparation. The efficiency in heating operation is only shown for high temperature (55 C). The efficiency of the heat generator in combination with the domestic hot water cylinder is also shown. Integrated system label During marketing (to the end customer), the integrated system label must be clearly visible as early as the quotation phase and the additionaldata sheet for the integrated system calculation must be filled out correctly and provided. The informationrequired for this must be provided by the manufacturer. The specified energy efficiency classes show the seasonal energy efficiency of the heat pump system in heating operation at low temperature (35 C) or high temperature (55 C) based on the label directive (2010/30/EU) and the eco-design directive (2009/125/EC) for a climate region with an outside temperature of -10 C. Dimplex A ++ A + A B C D E F G 58dB LA 18S-TU 55 C 35 C A ++ A db /2013 The following table shows the classification of the efficiency classes based on the required primary energy needs. With an efficiency value over 100%, the heat pump provides the building with more energy than is used to generate the required operating current. The higher the efficiency value, the higher the proportion of environmental energy used with the heat pump. Energy efficiency classes A++ A+ 35 C from 150 % 123 up to 150 % 55 C from 125 % 98 up to 125 % Example: A heat pump with efficiency class A++ provides at least 50% more heating energy than the amount of primary energy used for the power production in a heating system with a max. flow temperature of 35 C. General note Dimplex heat pumps for heating purposes are designed for use in a residential environment and correspond to the Low-voltage Directive. They are therefore also intended for use by layman for heating shops, offices, hotels and other similar working environments, in agricultural businesses or other residential buildings
4 Air-to-water heat pump for outdoor installation Heating and domestic hot water preparation package High-efficiency heat pump and Hydro-tower HPL 6TUW Heat output A7/W35 HPL TUW HPL 6TUW Heating package consisting of a high efficiency air-to-water heat pump for outdoor installation and Hydro-tower with integrated heat pump manager. Heat pump Extremely quiet thanks to sound-optimised casing and sound-insulated compressor housing High efficiency thanks to high-performance evaporator, EC fan and COP booster Integration of intelligent room temperature controllers (Smart RTC) enables a further increase in system efficiency Flexible expansion options via 2 mixer outputs for bivalent operation and/or the control of mixed heating circuits Use of load-variable tariffs (SG Ready) Hydro-tower Minimal installation effort thanks to the space-optimised combination of buffer tank and domestic hot water cylinder Simple coissioning with integrated heat pump manager and optimally coordinated hydraulic components Demand-based supplementary heating via switchable pipe heater (2/4/6 ) The electrical connection cable EVL.. UE between the heat pump and Hydro-tower must be ordered separately. HPL 6TUW Energy efficiency class / Energy efficiency (35 ) 158 % Energy efficiency class / Energy efficiency (55 ) 114 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 35 Heat output A-7/W35 / COP / 4.0 / 2.9 Heat output A2/W35 / COP / 5.1 / 3.8 Heat output A7/W35 / COP / 6.4 / 4.6 Sound power level db (A) 56 Sound pressure level in 10 m db (A) 28 Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.1 / 9500 Rated voltage 3/N/PE ~400 V, 50 Hz Heat output and coefficient of performance (COP) according to EN at A7/W35 (A7 = air intake temp. +7 C, W35 = heating water outlet temp. +35 C) For heating water connection cables with a length over 10 m, the free compressions listed in the device information must be observed (minimum pipe diameter for volume flows over 1.5 m³/h: DN 32)!
5 Air-to-water heat pump for outdoor installation Heating and domestic hot water preparation package High-efficiency heat pump and Hydro-tower Heat output A7/W35 HPL 9S-TUW HPL 12S-TUW HPL 18S-TUW (1 converter) HPL S-TUW 12S-TUW 9S-TUW NEUHEIT Heating package consisting of a high efficiency air-to-water heat pump for outdoor installation and Hydro-tower with integrated heat pump manager. Heat pump Simple hydraulic connection via the flexible connection kit (VS ) provided Extremely quiet thanks to sound-optimised casing and sound-insulated compressor housing High efficiency thanks to high-performance evaporator, EC fan and COP booster Integration of intelligent room temperature controllers (Smart RTC) enables a further increase in system efficiency Flexible expansion options via 2 mixer outputs for bivalent operation and/or the control of mixed heating circuits Hydro-tower Minimal installation effort thanks to the space-optimised combination of buffer tank and domestic hot water cylinder Simple coissioning with integrated heat pump manager and optimally coordinated hydraulic components Demand-based supplementary heating via switchable pipe heater (2/4/6 ) HPL...S-TUW HPL 9S-TUW HPL 12S-TUW HPL 18S-TUW Energy efficiency class / Energy efficiency (35 ) 177 % 173 % 182 % Energy efficiency class / Energy efficiency (55 ) 125 % 127 % 132 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 35 Heat output max. A-7/W35 / COP / 5.4 / / / 3.0 Heat output max. A2/W35 / COP / 7.0 / / / 3.9 Heat output A2/W35 / COP / 7.2 / / / 4.1 Heat output A7/W35 / COP / 8.4 / / / 4.8 (1 converter) Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.5 / / / 9700 Rated voltage 3/N/PE ~400 V, 50 Hz Universal design Heat output and coefficient of performance (COP) according to EN at A7/W35 (A7 = air intake temp. +7 C, W35 = heating water outlet temp. +35 C) LA 18S-TU and LA 9,12,18S-TUR available from June The values provided are preliminary data, which may still change before the start of series production!
6 Air-to-water heat pump for outdoor installation Heating, cooling and domestic hot water preparation package High-efficiency heat pump and Hydro-tower Heat output A7/W35 HPL 9S-TURW HPL 12S-TURW HPL 18S-TURW (1 converter) 7.5 (Teillast) HPL S-TURW 12S-TURW 18S-TURW NEUHEIT Cooling capacity A27/W18 HPL...S-TURW Package for heating and cooling consisting of a high efficiency air-to-water heat pump for outdoor installation and Hydro-tower with integrated heat pump manager. Heat pump Simple hydraulic connection via the flexible connection kit (VS ) provided Extremely quiet thanks to sound-optimised casing and sound-insulated compressor housing High efficiency thanks to high-performance evaporator, EC fan and COP booster Flexible expansion options via 2 mixer outputs for bivalent operation and/or the control of mixed heating circuits Hydro-tower Minimal installation effort thanks to the space-optimised combination of buffer tank and domestic hot water cylinder Simple coissioning with integrated heat pump manager and optimally coordinated hydraulic components Demand-based supplementary heating via switchable pipe heater (2/4/6 ) Silent cooling via panel heating/cooling systems requires the use of the room temperature controller with humidity sensor (RTM Econ) and a mixed heating circuit to regulate the flow temperature on the basis of the air temperature and humidity of a room. HPL 9S-TURW HPL 12S-TURW HPL 18S-TURW Energy efficiency class / Energy efficiency (35 ) 177 % 173 % 182 % Energy efficiency class / Energy efficiency (55 ) 125 % 127 % 132 % Energy efficiency class, XL / Energy efficiency (hot water preparation) 100 % 96 % 100 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 35 Lower / upper operating limit (cooling operation) C 15 / 40 Heat output max. A-7/W35 / COP / 5.4 / / / 2.9 Heat output max. A2/W35 / COP / 7.0 / 4.1 / / 3.8 Heat output A2/W35 / COP / 3.5 / / / 4.0 Heat output A7/W35 / COP / 8.2 / / / 4.7 Cooling capacity A27/W18 / EER / 7.9 / / / 3.8 (1 converter) Cooling capacity A35/W8 / EER / Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.5 / / / 9700 Rated voltage 3/N/PE ~400 V, 50 Hz Universal design reversible Heat output and coefficient of performance (COP) according to EN at A7/W35 (A7 = air intake temp. +7 C, W35 = heating water outlet temp. +35 C) The technical data for the heat pump can be found on the following pages. LA 18S-TU and LA 9,12,18S-TUR available from June The values provided are preliminary data, which may still change before the start of series production!
7 Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump For installation close to walls LA 6TU Heat output A7/W LA 6TU Heat pump for heating purposes for outdoor installation with wall-mounted WPM Econ5Plus heat pump manager. Sound-optimised through the use of slow-running owl s wing EC fans with a low natural sounding noise, an encapsulated compressor housing with swivelling compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator, electronic expansion valve and compliance with the requirements of EN for larger volume flows on the heat consumption side. High operational safety through sensor monitoring of the refrigeration circuit with demand-based defrosting; integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the heat pump manager). The minimum clearance from the wall is only 50 cm on the air intake side, which allows installation close to walls. Universal design for low-temperature heating systems with flexible expansion options for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs (SG Ready) At an external temperature of -10 C, the maximum flow temperature that can be achieved is 56 C. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. Dirt trap and flow rate switch built in. Electrical connection cable EVL.. UE between heat pump and heat pump manager must be ordered separately. LA 6TU LA 6TU Energy efficiency class / Energy efficiency (35 ) 155 % Energy efficiency class / Energy efficiency (55 ) 111 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -20 / 35 Heat output A-7/W35 / COP / 4.0 / 2.9 Heat output A2/W35 / COP / 5.1 / 3.8 Heat output A7/W35 / COP / 6.4 / 4.6 Sound power level db (A) 56 Sound pressure level in 10 m db (A) 28 Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.1 / 9500 Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1350 x 940 x 600 Gross weight 165 Universal design Heat output and coefficient of performance (COP) according to EN In snowy areas, the foundation must be of a sufficient height to guarantee a free air intake
8 Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump Heating with flexible expansion options LA 9S-TU LA 12S-TU Heat output A7/W35 LA 18S-TU (1 converter) LA S-TU 12S-TU 9S-TU NEUHEIT LA..S-TU Heat pump for heating purposes for outdoor installation with wall-mounted WPM Econ5S heat pump manager. Sound-optimised through flow-optimised air circuit with encapsulated compressor housing, axial fan for low natural sounding noise and free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) thanks to high-performance evaporator, COP booster, electronic expansion valve, EC fan for adjusting the air volume flow and self-optimising output control. Increased system efficiency (integrated system) can be achieved through combination with the Hydro-tower and room temperature control available as accessories. Maximum operational safety via sensor monitoring of the refrigeration circuit with self-optimising defrosting. This enables the downtimes in cycle operation to be used for natural defrosting; integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the heat pump manager). Quick and easy installation via installation close to walls with a minimal distance from the wall of 0. 5m on the intake side and a casing concept optimised for outdoor installation. Universal design with flexible expansion options for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs (SG Ready) At an external temperature of -10 C, the maximum flow temperature that can be achieved is 56 C. Dirt trap and sensor flow rate measurement integrated to safeguard the minimum heating water flow rate. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. The electrical connection between the control to be mounted in the building and the outdoor unit takes place via a shielded 2-wire data cable (e. g. LiYY; cross-section 0. 6 ²) not included in the scope of supply. The hydraulic connection can take place both at the bottom or on the side via the flexible connecting hoses available as accessories. Side panels light grey (similar to RAL 7035), front panels white (similar to RAL 9016), more colours available on request. LA 9S-TU LA 12S-TU LA 18S-TU Energy efficiency class / Energy efficiency (35 ) 172 % 167 % 176 % Energy efficiency class / Energy efficiency (55 ) 123 % 125 % 130 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 35 Heat output max. A-7/W35 / COP / 10.2 / 2.9 Heat output max. A2/W35 / COP / 13.0 / 3.8 Heat output A2/W35 / COP / 7.2 / / / 4.0 Heat output A7/W35 / COP / 8.4 / / / 4.7 (1 converter) Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.5 / / / 9700 Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 910 x 1650 x 750 Gross weight Universal design Heat output according to EN at A7/W35 (A7 = air intake temp. +7 C, W35 = heating water outlet temp. +35 C) LA 18S-TU and LA 9,12,18S-TUR available from June The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out. If this is not possible, a weather-proof protective cover must be mounted! The values provided are preliminary data, which may still change before the start of series production!
9 Air-to-water heat pump for outdoor installation Reversible high-efficiency air-to-water heat pump Heating and cooling with flexible expansion options Heat output A7/W35 Cooling capacity A27/W18 LA 9S-TUR LA 12S-TUR LA 18S-TUR (1 converter) 7.5 (Teillast) LA S-TUR 12S-TUR 9S-TUR NEUHEIT Reversible heat pump for heating purposes for outdoor installation for heating and cooling with wall-mounted heat pump manager WPM Econ5S. Sound-optimised through flow-optimised air circuit with encapsulated compressor housing, axial fan for low natural sounding noise and free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) thanks to high-performance evaporator, COP booster, electronic expansion valve, EC fan for adjusting the air volume flow and self-optimising output control. Maximum operational safety via sensor monitoring of the refrigeration circuit with self-optimising defrosting. This enables the downtimes in cycle operation to be used for natural defrosting; integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the heat pump manager). Quick and easy installation via installation close to walls with a minimal distance from the wall of 0. 5m on the intake side and a casing concept optimised for outdoor installation. Universal design with flexible expansion options for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs (SG Ready) At an external temperature of -10 C, the maximum flow temperature that can be achieved is 56 C. Silent cooling via panel heating/cooling systems requires the use of the room temperature controller with humidity sensor (RTM Econ) and a mixed heating circuit to regulate the flow temperature on the basis of the air temperature and humidity of a room. Dirt trap and sensor flow rate measurement integrated to safeguard the minimum heating water flow rate. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. The electrical connection between the control to be mounted in the building and the outdoor unit takes place via a shielded 2-wire data cable (e. g. LiYY; cross-section 0. 6 ²) not included in the scope of supply. Side panels light grey (similar to RAL 7035), front panels white (similar to RAL 9016), more colours available on request. LA..S-TUR LA 9S-TUR LA 12S-TUR LA 18S-TUR Energy efficiency class / Energy efficiency (35 ) 172 % 167 % 176 % Energy efficiency class / Energy efficiency (55 ) 123 % 125 % 130 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 35 Lower / upper operating limit (cooling operation) C 15 / 45 Heat output max. A-7/W35 / COP / 10.2 / 2.9 Heat output max. A2/W35 / COP / 13.0 / 3.8 Heat output A2/W35 / COP / 7.2 / / / 4.0 Heat output A7/W35 / COP / 8.4 / / / 4.7 (1 converter) Cooling capacity A27/W18 / EER / 7.9 / / / 3.8 (Teillast) Cooling capacity A35/W8 / EER / Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.5 / / / 9700 Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 910 x 1650 x 750 Gross weight Universal design reversible Heating, cooling capacity and coefficients of performance (COP/EER) according to EN LA 18S-TU and LA 9,12,18S-TUR available from June The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out. If this is not possible, a weather-proof protective cover must be mounted! The values provided are preliminary data, which may still change before the start of series production!
10 Air-to-water heat pump for outdoor installation Low temperature air-to-water heat pump For installation close to walls Heat output A7/W35 LA 11MAS LA 16MAS LA 11MAS LA MAS 16MAS Air-to-water heat pump for outdoor installation with outside temperature controlled WPM 2006 plus heat pump manager. Sound-optimised through the use of low-noise owl s wing fan blades. Energy-efficient defrosting by reverse circulation. High coefficients of performance (COP) thanks to compliance with EN for larger volume flows on the heat consumption side. Universal design with optional domestic hot water preparation and flexible expansion possibilities for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits The minimum clearances must be observed for installation close to walls. Integrated flow sensor and soft starter; return sensor and outside temperature sensor included in the scope of supply. The EVL... electric cable for connecting the heat pump and the heat pump manager, must be ordered separately. LA 11MAS LA 16MAS Energy efficiency class / Energy efficiency (35 ) 138 % 131 % Energy efficiency class / Energy efficiency (55 ) 113 % 103 % Max. flow temperature C 55 Lower / upper operating limit (heating operation) C -25 / 35 Heat output A-7/W35 / COP / 5.7 / / 2.6 Heat output A2/W35 / COP / 7.9 / / 3.1 Heat output A7/W35 / COP / 9.5 / / 3.7 Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.7 / / Rated voltage 1/N/PE ~230 V, 50 Hz Dimensions (W x H x D) 1050 x 1340 x x 1550 x 852 Gross weight Universal design Heat output and coefficient of performance (COP) according to EN The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out
11 Air-to-water heat pump for outdoor installation Air-to-water heat pump For installation close to walls Heat output A7/W35 LA 11TAS RG2 LA 16TAS RG LA TAS 11TAS RG Price in Air-to-water heat pump for outdoor installation with outside temperature controlled WPM 2006 plus heat pump manager. Sound-optimised through the use of low-noise owl s wing fan blades. Energy-efficient defrosting by reverse circulation. High coefficients of performance (COP) thanks to compliance with EN for larger volume flows on the heat consumption side. Universal design with optional domestic hot water preparation and flexible expansion possibilities for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits The minimum clearances must be observed for installation close to walls. Integrated flow sensor and soft starter; return sensor and outside temperature sensor included in the scope of supply. The EVL... electric cable for connecting the heat pump and the heat pump manager, must be ordered separately. LA..TAS LA 11TAS LA 16TAS Energy efficiency class / Energy efficiency (35 ) 148 % 130 % Energy efficiency class / Energy efficiency (55 ) 106 % 104 % Max. flow temperature C 58 Lower / upper operating limit (heating operation) C -25 / 35 Heat output A-7/W35 / COP / 7.2 / / 2.7 Heat output A2/W35 / COP / 8.6 / / 3.2 Heat output A7/W35 / COP / 10.2 / / 3.7 Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 1.9 / / Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1050 x 1340 x x 1550 x 852 Gross weight Universal design Heat output and coefficient of performance (COP) according to EN The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out
12 Air-to-water heat pump for outdoor installation Air-to-water heat pump With two performance levels LA 22TBS LA 28TBS Heat output A7/W35 / Heat output max. A7/W LA TBS 28TBS LA 28TBS Heat pump for heating purposes for outdoor installation with wall-mounted heat pump manager WPM Econ and two compressors for output regulation when operating at partial load. Sound-optimised through flow-optimised, tapering casing with encapsulated compressor housing, axial fan for low natural sounding noise and free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator and EC fan for COP-optimised adaptation of the air volume flow. FWO function for more efficient domestic hot water preparation with increased domestic hot water temperatures and volumes of water to be drawn through optimised tank charging. High operational reliability through sensor monitoring of the refrigeration circuit with demand-based defrosting via reverse circulation and integrated thermal energy metering (display of the calculated quantity of thermal energy for heating, domestic hot water and swiing pool water preparation on the heat pump manager). Universal design with optional domestic hot water preparation and flexible expansion possibilities for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs At an external temperature of -10 C, the maximum flow temperature that can be achieved is 60 C. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. Dirt trap and flow rate switch built in. The electrical connection between the control to be mounted in the building and the outdoor unit takes place via a shielded 2-wire data cable (e. g. LiYY; cross-section 0. 6 ²) not included in the scope of supply. LA 22TBS LA 28TBS Energy efficiency class / Energy efficiency (35 ) 153 % 154 % Energy efficiency class / Energy efficiency (55 ) 117 % 121 % Max. flow temperature C 65 Lower / upper operating limit (heating operation) C -22 / 35 Heat output max. A-7/W35 / COP / 12.0 / / 2.9 Heat output max. A2/W35 / COP / 14.7 / / 3.4 Heat output A2/W35 / COP / 8.6 / / 3.5 Heat output A7/W35 / COP / 10.6 / / 4.2 Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 3.3 / / Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1065 x 1855 x 775 Gross weight Universal design Heat output and coefficient of performance (COP) according to EN The higher flow temperatures are available for domestic hot water preparation all year round. The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out
13 Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump With two performance levels LA 25TU LA 40TU LA TU 25TU Heat output A7/W35 / Heat output max. A7/W35 Heat pump for heating purposes for outdoor installation, with wall-mounted WPM Econ5Plus heat pump manager and two compressors for output control during partial load operation. Sound-optimised through the use of slow-running owl s wing fans with a low natural sounding noise, an encapsulated compressor housing with free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator and compliance with the requirements of EN for larger volume flows on the heat consumption side. High operational safety through sensor monitoring of the refrigeration circuit with demand-based defrosting; integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the heat pump manager). Access for service work on the outlet side; the minimum clearances must be observed for installation close to walls. Universal design with two compressors for modulating operation, optional domestic hot water preparation and flexible expansion options for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs (SG Ready) Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. Dirt trap included in the scope of supply. Electrical connection cable EVL.. U between heat pump and heat pump manager must be ordered separately. LA 25TU LA 40TU LA 25TU LA 40TU Energy efficiency class / Energy efficiency (35 ) 175 % 179 % Energy efficiency class / Energy efficiency (55 ) 126 % 127 % Max. flow temperature C 58 Lower / upper operating limit (heating operation) C -25 / 35 Heat output max. A-7/W35 / COP / 16.7 / / 3.0 Heat output max. A2/W35 / COP / 19.6 / / 3.8 Heat output A2/W35 / COP / 11.3 / / 3.9 Heat output A7/W35 / COP / 13.9 / / 4.6 Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 4.5 / / 3900 Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1600 x 1940 x x 2100 x 952 Gross weight Universal design Heat output and coefficient of performance (COP) according to EN The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out. If this is not possible, a weather-proof protective cover must be mounted!
14 Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump With two performance levels LA 60TU LA TU Heat output A7/W35 / Heat output max. A7/W35 LA 60TU Heat pump for heating purposes for outdoor installation, with wall-mounted WPM Econ5Plus heat pump manager and two compressors for output control during partial load operation. Sound-optimised through the use of two slow-running EC-3D fans, an encapsulated compressor housing and a free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator, electronic expansion valve and compliance with the requirements of EN for larger volume flows on the heat consumption side. High operational safety through sensor monitoring of the refrigeration circuit with demand-based defrosting; integrated thermal energy metering (display of the calculated quantity of thermal energy for heating and domestic hot water preparation on the heat pump manager). Access for service work on the outlet side; the minimum clearances must be observed for installation close to walls. Can be easily transported with a lift truck (accessible from underneath) or lifting lugs. Universal design with two compressors for modulating operation, optional domestic hot water preparation and flexible expansion options for: Bivalent or bivalent-renewable operating mode Distribution systems with unmixed and mixed heating circuits Use of load-variable tariffs (SG Ready) At an external temperature of -10 C, the maximum flow temperature that can be achieved is 60 C. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. Dirt trap and flow rate switch built in. Electrical connection cable EVL.. UE between heat pump and heat pump manager must be ordered separately. LA 60TU Energy efficiency class / Energy efficiency (35 ) 160 % Energy efficiency class / Energy efficiency (55 ) 126 % Max. flow temperature C 65 Lower / upper operating limit (heating operation) C -22 / 35 Heat output max. A-7/W35 / COP / 39.2 / 2.9 Heat output max. A2/W35 / COP / 50.0 / 3.6 Heat output A2/W35 / COP / 26.4 / 3.7 Heat output A7/W35 / COP / 31.9 / 4.3 Sound power level db (A) 74 Sound pressure level in 10 m db (A) 50 Heating water flow rate / pressure drop acc. EN m³/h / Pa 10.4 / 8300 Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1900 x 2300 x 1000 Gross weight 915 Universal design Heat output and coefficient of performance (COP) according to EN The flow temperatures that can be achieved depending on the heat source temperature can be derived from the operating limits diagram
15 Air-to-water heat pump for outdoor installation Reversible high-efficiency air-to-water heat pump Optimised for heating and cooling LA TUR+ 35TUR Heat output A7/W35 / Heat output max. A7/W35 LA 35TUR LA 60TUR Cooling capacity A27/W18 / Cooling capacity 2 compressor Heat pump for heating and cooling purposes for outdoor installation with wall-mounted heat pump manager and two compressors for output control in partial load operation. Sound-optimised by electronically controlled fans and an encapsulated compressor housing with free-swinging compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through high-performance evaporator and compliance with the requirements of EN for larger volume flows on the heat consumption side. Optimised heating and cooling operation via an external four-way reversing valve which is activated by the controller (special accessory). High operational safety through sensor monitoring of the refrigeration circuit for demand-based defrosting; integrated thermal energy metering (display of the thermal energy volume for heating and domestic hot water preparation on the WPM EconR heat pump manager). Reversible refrigeration circuit with additional heat exchanger for higher domestic hot water temperatures in heating operation and waste heat recovery in cooling operation. Access for service work on the outlet side; the minimum clearances must be observed for installation close to walls. Can be easily transported with a lift truck (accessible from underneath) or lifting lugs. Universal design with flexible expansion options for: Bivalent or bivalent-renewable operating mode Unmixed and mixed heating and cooling circuit At an external temperature of -10 C, the maximum flow temperature that can be achieved is 56 C. Silent cooling via panel heating/cooling systems requires the use of the room climate station (special accessory) to regulate the flow temperature on the basis of the air temperature and humidity of a room. Flow and return sensor integrated; external sensor (standard NTC-2) in the scope of supply. Dirt trap included with LA 35TUR+; LA 60TUR+ with built-in flow rate switch and dirt trap. Electrical connection cable EVL.. U between heat pump and heat pump manager must be ordered separately. LA 60TUR+ LA 35TUR+ LA 60TUR+ Energy efficiency class / Energy efficiency (35 ) 176 % 153 % Energy efficiency class / Energy efficiency (55 ) 127 % 122 % Max. flow temperature C 60 Lower / upper operating limit (heating operation) C -22 / 40 Lower / upper operating limit (cooling operation) C 10 / 45 Heat output max. A-7/W35 / COP / 17.6 / / 3.0 Heat output max. A2/W35 / COP / 23.6 / / 3.4 Heat output A2/W35 / COP / 13.6 / / 3.5 Heat output A7/W35 / COP / 17.3 / / 4.2 Cooling capacity A27/W18 / EER / 19.1 / / 4.0 Cooling capacity A35/W8 / EER / 24.9 / / 2.3 Sound power level db (A) Sound pressure level in 10 m db (A) Heating water flow rate / pressure drop acc. EN m³/h / Pa 5.2 / / Rated voltage 3/N/PE ~400 V, 50 Hz Dimensions (W x H x D) 1735 x 2100 x x 2300 x 1000 Gross weight Universal design reversible Heating, cooling capacity and coefficients of performance (COP/EER) according to EN The performance levels stated can only be achieved in combination with the external four-way valve available as a special accessory. When installing an optional residual-current circuit-breaker, an RCD type B must be used, which detects AC and pulsating DC residual currents, as well as smooth DC residual currents
16 Air-to-water heat pump for outdoor installation Smart RTC+ intelligent room temperature control RTM Econ U A RTM Econ U The Smart RTC+ is used for room temperature control. Up to 10 rooms per heating circuit can be equipped with one controller each. The room regulation in several rooms achieves the highest efficiency with maximum comfort. The controller can be used for heat pumps with heat pump manager WPM Econ5, WPM Econ5S and WPM Econ5Plus from software version L22.- Power supply ~230 V (2-wire)- Bus connection (2-wire shielded)- Digital switching output for controlling actuators (230 V)Functions:- Can be used for heating and silent cooling- Room temperature and humidity recorded and displayed- Adjustment of the room set temperature- Adjustment of the operating modes Auto Cooling Quick-heat function For device type Width x Height x Depth RTM Econ U LA..S-TU Flush-mounting version 86 x 86 x 28 LA..S-TUR RTM Econ A LIK 12TU Surface-mounting version 143 x 86 x 36 Coissioning by the after-sales service is required for room temperature control of up to 10 rooms (smart RTC+). Electric connection line heat pump heat pump manager Essential accessories EVL 10U 20U 30U 40U Two separate control cables between heat pump manager WPM Econ5Plus / EconR and the high efficiency air-to-water heat pump for outdoor installation. Ready for use with coded plug connections (confusion-proof through identical plug connections on both cable ends) for laying in a protection tube (pipe Ø at least 70 ). EVL..U For device type Length m EVL 10U LA 25 40TU EVL 20U LA 35TUR EVL 30U EVL 40U Essential accessory for high-efficiency air-to-water heat pumps. The laying should take place separately from the mains cable. An extension of the control cable on-site is not permitted and will result in a loss of warranty on the heat pump! The max. length of the hydraulic connection should not exceed 30 m. Electric connection line heat pump heat pump manager Essential accessory for heat pumps with electronic expansion valve EVL 10UE 20UE 30UE 40UE EVL 10UE Three separate control cables between heat pump manager WPM Econ5Plus and the high efficiency air-to-water heat pump with electronic expansion valve for outdoor installation. Ready for use with coded plug connections (confusion-proof through identical plug connections on both cable ends) for laying in a protection tube (pipe Ø at least 70 ). For device type Length m EVL 10UE LA 6TU EVL 20UE LA 60TU LA 60TUR EVL 30UE EVL 40UE Essential accessory for high-efficiency air-to-water heat pumps. The laying should take place separately from the mains cable. An extension of the control cable on-site is not permitted and will result in a loss of warranty on the heat pump! The max. length of the hydraulic connection should not exceed 30 m
17 Air-to-water heat pump for outdoor installation Electric connection line heat pump heat pump manager EVL Control cable between the heat pump manager and the air-to-water heat pump for outdoor installation. Made ready for connection with coded plug connections on both ends for laying in a protection tube (diameter min. 70, unmistakable: round plugs for connection to the heat pump). For device type Length m EVL LA..TAS/MAS EVL EVL EVL EVL... The laying should take place separately from the mains cable. An extension of the control cable on-site is not permitted and will result in a loss of warranty on the heat pump! The max. length of the hydraulic connection should not exceed 30 m. Pipe assembly for air-to-water heat pumps LA...S-TU VS Wellflex hose set, bent, for connecting an air-to-water heat pump from the LA...S-TU series to the heating system. Consisting of two DN 25 insulated stainless steel Wellflex pipes with cap nuts 1¼" internal thread. For device type Connection heating " VS LA...S-TU 1¼ Pipe assembly for LA...TU air-to-water heat pumps For connection from the side 6U 25U 40U 40ZWT UR RBS 60ZWT The pipe assembly which can be screwed directly into the heat pump consists of two specially bent pipes adapted to the high-efficiency air-to-water heat pump with couplings for the heating water connection. For installation close to external walls, above-ground feed into the building is possible with these pipe assemblies (base frame air outlet side, on the right below the fan, on the left with LA 6TU) running out of the side of the heat pump (thermal insulation for frost protection required). This removes the need for the standard underground pipework feed used for feeding into cellars. For device type Connection heating " RBS 6U LA 6TU RBS 25U LA 25TU 1½ 2.7 RBS 40U LA 40TU LA 35TUR+ RBS 40ZWT Additional heat exchanger LA 35TUR+ RBS 60U LA 60TU RBS 60UR LA 60TUR+ RBS 60ZWT Additional heat exchanger LA 60TUR+ 1¼ RBS..U When planning the heat pump foundation, observe the insulation thickness for flow and return, the wall clearance and the pipe slope
18 Air-to-water heat pump for outdoor installation Weather-proof protective cover for LA...TU air-to-water heat pumps WSH Design weather-proof protective cover for retrofitting high-efficiency air-to-water heat pumps; required for uncovered outdoor installation, when the air intake or the air outlet side is exposed to strong winds. WSH 40 For device type Width x Height x Depth WSH LA 9 18S-TU 855 x 849 x WSH LA 25TU 1600 x 1225 x WSH LA 40TU LA 35TUR x 1385 x Weather protection hood WSH 18 available from June 2015 Weather-proof protective cover for LA...TBS air-to-water heat pump WSH Design weather-proof protective cover for retrofitting on air-to-water heat pumps from the TBS series in outdoor installation; required for uncovered outdoor installation, when the air intake or the air outlet side is exposed to strong winds. WSH 800 For device type Width x Height x Depth WSH LA 22TBS LA 28TBS 797 x 866 x Flow rate switch DFS DFS Flow rate switch for installation in the generator circuit of an air-to-water heat pump, to guarantee the water flow prior to the compressor start and during defrosting. Installation length 200! For device type Switch point m³/h Connection heating " DFS LA..TAS/MAS 1.3 1¼ 2.0 DFS LA 25TU 1.7 1½ 2.5 DFS LA 40TU 2.2 When installing electronically controlled circulating pumps in the generator circuit of an air-to-water heat pump with defrosting by reverse circulation, a flow rate switch is required, which blocks the heat pump when the required minimum heating water flow rate is not reached. Exception: UPH pump series with activated temperature difference measurement Condensate drain heater KAH KAH 150 Self-regulating band heater for heating the condensate drain hose of air-to-water heat pumps. Pre-installed cooling conductor for connecting to the power supply of the heat pump. For installation in the condensate drain hose (heated length 1.5 m). Delivery including installation material for parallel operation with the nozzle ring heater. Length m Rated power W Rated voltage KAH /N/PE ~230 V, 50 Hz Recoended accessories if frost-free condensate drain cannot be ensured outside of the heat pump (for example, in colder regions with long frost periods)
19 Air-to-water heat pump for outdoor installation Heating water connection cable, heat pump heating system Optimised for connection to a heat pump HVL Buriable insulated 2-pipe system with ready-to-use 90 bend (bend radius 200 ) for vertical connection of a heat pump in outdoor installation. Suitable for heat pumps for heating and cooling; max. operating temperature 95 C; max. operating pressure 6 bar (at 65 C 9 bar); load class SWL 60 (33 kn/m 2 ). Consisting of PE-Xa medium pipes with EVOH oxygen diffusion blocking layer, closed-cell linked PE foam and a highly flexible corrugated PE-HD cover pipe; including a connection pipe pre-assembled in the 90 angle with a length of 1.2 m for quick and easy connection to the heat pump, incl. two PE end caps, warning tape Warning district heating and four screw connections, each with two 1¼" internal and external threads. HVL.. Connection heating " HVL ¼ Length 5 m m connection pipe 2x32/2.9 Ø cover pipe HVL Length 7.5 m m connection pipe 2x32/2.9 Ø cover pipe HVL Length 10 m m connection pipe 2x32/2.9 Ø cover pipe HVL Length 15 m m connection pipe 2x32/2.9 Ø cover pipe For high-efficiency heat pumps, additional transitional screw connections are required, from 1¼" thread-sealing to 1½" flat-sealing. The pressure drops required for the pump dimensioning must be taken from the installation manual. Connection heat pump heating water connection cable Optimised for connection to a heat pump VSF Flexible hose connection set, length 250, for quick and easy connection of an air-to-water heat pump in outdoor installation to a buried heating water connection cable. Consisting of two insulated stainless steel Wellflex pipes with cap nuts and screw connections. VSF.. For device type Connection heating " VSF LA...TBS 1¼ Stainless steel Wellflex DN VSF LA 25TU Stainless steel Wellflex DN 32 Due to the increased risk of dirt deposits coming loose from flexible connections, a dirt trap must be installed in front of the heat pump! House infeeds for heating water connection cable For pressuring and non-pressuring water MDM MDF House infeeds as an accessory for HVL 25 heating water connection cables. The MDM sealing collars, consisting of a protection tube with shrink hose, are suitable for non-pressuring water (rain water, surface water and leakage water). The MDF sealing flange (stainless steel V2A) is suitable for pressuring water (slope water, ground water, plain tracts and water veins). Short text MDM Wall-sealing collar (protection tube with shrink hose) MDF Wall-sealing flange (stainless steel V2A) Sealing collar for HVL 25 (cover Ø 145 ) as a house infeed (recoended drilling Ø 220 ) through brickwork Wall-sealing flange for HVL 25 (cover Ø 145 ), sealing width 80, recoended drilling Ø 250 In brick walls:the house infeeds must be sealed against penetrating water with a bituminous protective coating. To seal against pressuring water, the house infeed (MDF) must also be stabilised with a scabbard tube MDM.. MDF
20 Air-to-water heat pump for outdoor installation General installation material for connecting the heat pump to the heating system SMF AS SCHT TUE SMF.. AS... TUE... Short text Connection heating " SMF DN 25 dirt trap 1 Mesh size SMF DN 32 dirt trap 1¼ Mesh size 0.6 e.g. LA 17PS 1.21 AS Connecting hose 1" (25 x 4.5 ) AS Connection hose 1¼" (32 x 5.5 ) SCHT " external thread hose nozzle for 1" connecting hose SCHT ¼" external thread hose nozzle for 1" connecting hose SCHT ¼" external thread hose nozzle for 1¼" connecting hose 1 Flexible, compression-proof hose for connecting 7.0 the heat pump to the heating system, max. 1¼ permissible temperature 80 C, length 10 m, can be cut to length, without insulation Hose nozzle with external thread and hose 0.2 clip for connecting hose (for connection to the 1¼ heating system e.g. compact manifold). 0.3 TUE " nozzle for 1" connecting hose 1 Nozzle with cap nut (internal thread) for connecting 0.2 TUE ¼" nozzle for 1¼" connecting hose 1¼ hose (for connection to heat pump). 0.3 Their allocation to heat pumps and further information concerning the recoended use of the expansion joints can be found in the product section on heat pump distribution systems. Due to the increased risk of dirt deposits coming loose from flexible connections, a dirt trap must be installed in front of the heat pump! SCHT... Four-way reversing valve for reversible heat pumps Special hydraulic accessories for cooling VWU 32E 40E 50E The 4-way reversing valve (1¼", 1½" or 2" internal thread) for integration in the flow allows optimised operation for heating and cooling. Switching takes place via an electromotive actuator (1/N/PE ~230 V, 50 Hz) which is activated by the heat pump manager. VWU..E For device type Maximum volume flow m³/h VWU 32E LA 35TUR+ 8 Four-way reversing valve DN 32 with actuator Rp 1¼" k VS VWU 40E LA 35TUR+ SI 30TER+ VWU 50E LA 35TUR+ LA 60TUR+ SI 75TER+ 10 Four-way reversing valve DN 40 with actuator Rp 1½" k VS Four-way reversing valve DN 50 with actuator Rp 2" k VS 40 Energy-efficient circulating pumps for the heat generator circuit UPH 80-40F High-efficiency heat circulating pumps to guarantee the minimum heating water flow rate through the heat pump, delivery height 7 m at a volume flow of 8.0 m 3 /h, fixed speeds saved, pump can be controlled with 0 10 V input signal, inside micrometer 220, connection flange DN 40; incl. thermal insulation Yesckets; connection voltage 1/N/PE ~230 V, 50 Hz; relay for decoupling controller and circulating pump in scope of supply. UPH 80-40F For device type Nominal width UPH 80-40F LA 60TU LA 60TUR+ 40 Delivery height 7 m with a volume flow of 8.0 m 3 /h; fixed speeds, control types Δp-c and Δp-v saved, control with 0-10 V input signal possible, flange connection DN 40, delivery incl. thermal insulation Yesckets! 18.1 Available from June
Product Range. Overview 2015.
Product Range. Overview 2015. Simply More Efficiency Simply individual. The Dimplex colour concept. Surface finish: Choose from 1625 colours. Air-to-water heat pumps are designed for outdoor installation
More informationProduct Range Overview 2010
Product Range Overview Renewable Energies Heat Pumps Solar Thermal Systems Domestic Heating Products Heatpumps Solar Thermal Systems Domestic Heating Systems Contents Heat pump for heating purposes air
More informationStarting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)
Data sheet LA 16MS Air-to-water heat pump with deflector hoods Max. flow temperature: 58 C Casing colour: White aluminium (similar to RAL 9006) Air-to-water heat pump for outdoor installation with external
More informationStarting current with soft starter Fuse protection
Data sheet LIH 26TE High temperature air-to-water heat pump Max. flow temperature: 75 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for
More informationDimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference
Data sheet LI 9TU High efficiency air-to-water heat pump for indoor installation. Max. flow temperature: 60 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for
More informationStarting current with soft starter Fuse protection. Heat source connection
Data sheet SI 17TE Brine-to-water heat pump max. flow temperature: 58 C Casing colour: white Brown-red design screen (RAL 3011) Heat pump for indoor installation with integrated regulation WPM 2007 plus.
More informationTechnical data LA 60TUR+
Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors
More informationStarting current with soft starter Fuse protection
Data sheet SI 14ME Brine-to-water heat pump Max. flow temperature: 58 C Casing colour: White (similar to RAL 9003) Brown-red design screen (RAL 3011) Heat pump for heating purposes for indoor installation
More informationPRODUCT DATA SHEETS HEAT PUMPS
PRODUCT DATA SHEETS HEAT PUMPS HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIERSAL DESIGN - MAX. FLOW TEMPERATURE 70 C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE
More informationTechnical data LA 60TU
Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationTechnical data LA 9S-TU
Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationTechnical data LA 28TBS
Technical data LA 28TBS Device information LA 28TBS Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance
More informationData sheet SI 24TE. Brine-to-water heat pump with two performance levels
Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes
More informationA Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser
Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,
More informationAir / Water Heat Pump - Compact Design Modulating 8 18 kw
Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More informationVIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O
VIESMANN VITOCAL Air/water heat pumps Technical guide VITOCAL 300-A Type AWC-I and AW-O Up to 60 C flow temperature Modulating output range 3 to 9 kw Reversible air source heat pump with electric drive
More informationStainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW
Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents
More informationA-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.
A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat
More informationTechnical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages
Technical Data Sheet Air Ground Water Brine Cooling PV-ready Modulation Brine/Water Heat Pumps 8 12kW - single phase 230V Heliotherm Basic Comfort A fully modulating Brine/Water heat pump with leading-edge
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationAIR GOLF MAXI PLUS. Heat Source Air. Technical data: High-efficiency air/water heat pumps. for tfl. max. 65 C
24 Heat Source Air AIR GOLF MAXI PLUS High-efficiency air/water heat pumps for tfl. max. 65 C Series HEATING HEATING/COOLING Dimensions LxWxH [mm] 1150 x 400 x 650 1150 x 600 x 650 Model GMLW 5 plus GMLW
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationFlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality
FlexLine Steam humidifier New flexibility in award-winning quality A series of units with a wide performance range for every area of application Individual confi guration Easy operation Highest quality
More informationAdconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h
Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationPRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.
PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION
More informationThermostatic valves with radiator connection systems
Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator
More informationInstallation and operating instructions. DK energy storage and DK energy buffer
Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The
More informationE-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems
E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationControl valves for floor heating systems. Floor Heating Manifolds
Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control
More informationAluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support
Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of
More informationResolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h
Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:
More informationMODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33
Inverter-driven air source heat pump systems Dimplex Air-Eau is an exciting new range of inverter-driven air source heat pumps designed to match output to varying heating demand. With achievable CoPs of
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationAdsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system
Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical
More informationPAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED
PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationA w rld of new product innovation new product launches
A w rld of new product innovation 2011 new product launches Welcome to our w rld Dimplex is proud to announce a set of new product ranges that significantly enhance our portfolio of renewable energy technologies.
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationCalypso exact. Thermostatic Radiator Valves With stepless precision presetting
Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are
More informationAir to water Heat Pump System
Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a
More informationAir Conditioner. user installation & manual manual. imagine the possibilities
ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationInstallation Instructions
38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes
More informationHPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501
HPWH 300 HPWH 300HE Installation and Operating Instructions Hot Water Heat Pump for Outdoor Installation FD 9501 Table of contents 1 Please read immediately... EN-2 1.1 Important notes... EN-2 1.2 Intended
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationPro heat station brine
Pro heat station brine PWZS / overview 3~400V type overview 3~400V heating capacity at kw at B0/W35 COP at B0/W35 PWZS 42H3S 4,7 4,7 PWZS 62H3S 6,0 4,8 PWZS 82H3S 7,7 4,9 PWZS 102H3S 9,5 5,0 PWZS 122H3S
More informationAluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support
Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of
More informationPRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.
PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationQAF64.2-J QAF64.6-J. Frost detector. for use on the air side
s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage
More informationFor a future without oil and gas.
For a future without oil and gas. Heat pumps make you independent. Heat pumps for utilising the air, the ground and ground water as heat sources Heat pumps for new buildings and modernisation Heat pumps
More informationMachine needle shut-off nozzle Type SHP (high performance) spring operated
Machine needle shut-off nozzle Type SHP (high performance) spring operated Applications: thermoplastics (not applicable for PVC) Shot-off mechanism: Operated with one high performance spring Index of contents
More informationAir/water - Heat pumps
Air/water - Heat pumps Installation of a NIBE air/water heat pump can lead to your energy consumption for heating being reduced by up to 50%, in comparison to conventional heating systems. Areas of Use
More informationPlanning guide. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationPress. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity
Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity What s new at a glance: - This year, Viessmann is launching a whole new series of innovative air/water heat pumps
More informationAMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.
AMONUM chillers Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.de INTRO AMONUM chillers are efficient, compact and natural Ammonia is
More informationAIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round
AIR TO WATER HEAT PUMPS Hot water and comfortable ambient temperature all year round HEAT PUMP PRINCIPLE CARRIER. A UNITED TECHNOLOGIES COMPANY Whether you need air conditioning for a new building or a
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationA/C-HEATER SYSTEM - MANUAL
A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationCold water HD 9/18-4 ST
Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationEclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic
More informationREMKO Comfort-WP The versatile heat pump
REMKO Comfort-WP The versatile heat pump Issue 2012 Independent from oil and gas Cosy heat in the winter A pleasant climate in the summer CMF Series 1-2014 Quality with systems REMKO THE CUSTOMER-ORIENTED
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationFan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions
Fan-and-filter units Features Fan-and-filter units are ideal for dissipating heat loads costeffectively. The pre-requisite is that the ambient air must be relatively clean and with a temperature below
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationyour comfort. our world. Altherma Flex Type Renewable heat pump system for every environment
your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma
More informationHeat pump systems and Chillers
PRODUCT OVERVIEW Heat pump systems and Chillers HIdROS was formed in 1993 as a distribution company operating in the humidification and dehumidification sector of the air conditioning market. The expansion
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY
Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water
More informationThermostatic valve bodies
Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single
More informationWZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0
WZS 4(H)(K)M WZS 6(H)(K)M WZS 8(H)(K)M WZS (H)(K)M WZS 1(H)(K)M 0 I 60-5 5 B0W65 1 4 I I I -1 50 (58) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1 55 (6) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1
More informationKüba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing
High-performance air cooler for blast chilling and shock freezing engineering for a better world GEA Heat Exchangers High-performance air cooler for blast chilling and shock freezing Large fin spacing
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationEclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic
More informationcondensate pumps For air conditioning and refrigeration technology eckerle.com
condensate pumps For air conditioning and refrigeration technology eckerle.com Condensate pumps in air conditioning technology Condensation is the change of state of the physical state of matter from gas
More informationFor reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting
For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed
More informationNABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.
NABILATON PRO NABILATON PRO KIT The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton. INVERTER TECHNOLOGY Increasing the compressor motor rotation
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationRoth fixed-value control set with high-efficiency pump
Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical
More informationDanfoss Air Heating Surfaces
MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationThermostatic valve bodies
Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents
More informationELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual
www.elektra.eu ELEKTRA HEATING MATS Designed to be installed under laminate flooring and/or engineered wood Installation manual Instrukcja montażu Èíñòðóêöèÿ ïî ìîíòàæó UK PL RU Purpose The ELEKTRA WoodTec
More informationV-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting
V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve
More informationHeat Pumps. Compact. Device Information. Operating manual supplement. LWC Series
Device Information UK Air/Water Operating manual supplement Compact Heat Pumps LWC Series Please read first The Special Version Device Information is a component of the product. It complements the operating
More information