SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.
|
|
- Merry Clarke
- 6 years ago
- Views:
Transcription
1 SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_ Products that provide lasting solutions.
2
3 Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse Coolers or Freezers to Fit a Wide Range of Capacities n Ruggedly constructed fan cabinet hung by hanger rods from the ceiling. n Efficient air drawthru design with 30 diameter aluminum fans for uniform air distribution; air throw is approximately 50 to 60 feet. n 1 HP high efficiency 3phase, 850 RPM fan motors are permanently lubricated. n Air defrost for medium temperature rooms. n Electric or hot gas defrost for medium and low temperature rooms. n Adjustable defrost termination and fan delay thermostat installed with electric defrost. n Bypass tee installed with hot gas defrost. Check valve provided shipped loose. n Mill galvanized drain pan and fan cabinet. n Drain pan is insulated for electric or hot gas defrost applications. n Drain pan and fan cabinet end panels are hinged for easy access and cleaning. n 4, 5, 6, and 7 fins per inch spacing. n Coated, corrosionresistant wire fan guards. n Compartmental fan sections. n 3phase, ball bearing motors 230/460V or 575V. n Suction Schrader valve for easy suction pressure/ temperature measurement. Optional Features n Cooler can be used with fluid applications. n Brine and heat reclaim circuiting. n Stainless steel housing and drain pan. n Insulated drain pan cover for air defrost models. n ElectroFin/Heresite coated coil for air defrost and hot gas models. n Painted housing. n Copper fins. Optional Accessories n Long throw air boosters (air throw approx. 100 feet). n Room thermostat. n Thermostatic expansion valve. n Liquid line solenoid valve. n Suction liquid heat exchanger. SV SERIES Designed to Deliver Low Temperature Air at ExtraHigh Velocity in Freezers n Ruggedly constructed fan cabinet hung by hanger rods from the ceiling. n Wide capacity range. n Efficient air drawthru design with 30 diameter aluminum fans for uniform air distribution; air throw is approximately 60 to 80 feet. n 1.5 HP high efficiency 3phase, 1140 RPM fan motors are permanently lubricated. n Electric or hot gas defrost for low temperature rooms. n Adjustable defrost termination and fan delay thermostat installed. n Mill galvanized drain pan and fan cabinet. n Insulated drain pan. n Drain pan and fan cabinet end panels are hinged for easy access and cleaning. n 4, 5, and 6 fins per inch spacing. n Coated, corrosionresistant wire fan guards. n Compartmental fan sections. n 3phase, ball bearing motors 230/460V or 575V. n Suction Schrader valve for easy suction pressure/ temperature measurement. Optional Features n Stainless steel housing and drain pan. n ElectroFin/Heresite coated coil for hot gas defrost models. n Painted housing. n Copper fins. Optional Accessories n Long throw air boosters (air throw approx. 120 feet). n Room thermostat. n Thermostatic expansion valve. n Liquid line solenoid valve. n Suction liquid heat exchanger. 1
4 Ordering Information Specify When Ordering All Models n Complete model number. n Refrigerant R404A, R407A, R407C, R407F, R507, and R448A / R449A. n Room temperature. n Saturated suction temperature. n Liquid refrigerant temperature. n 230/3, 460/3 or 575/3 motor and heater voltage. n Optional features. n Optional accessories. Model Key SM 2 5 E 842 C K K Heater Voltage Unit Type SM = Space Master SV = High Velocity SM Number of Fans Fin Spacing 4 FPI 5 FPI 6 FPI 7 FPI K=208203/3/60 M= 460/3/60 P=575/3/60 U= 380/3/50 (not UL) L=380/3/60 Motor Voltage K=208203/3/60 M= 460/3/60 P=575/3/60 U= 380/3/50 (not UL) L=380/3/60 Motor Type Type of Defrost A = Air B = Brine E = Electric with Electric Pan G = 3 Pipe Hot Gas with Hot Gas Drain Pan H = 3 Pipe Hot Gas with Electric Drain Pan K = 2 Pipe Kool Gas with Kool Gas Drain Pan P = 2 Pipe Kool Gas with Electric Drain Pan R = Heat Reclaim U L C C=3Phase Motors Inverter Duty Suitable Motor (Standard for 230 and 460 voltages) U L BTU/h in Hundreds (00) 2
5 Air Defrost High Profile MODEL SM14A314 SM16A378 SM17A410 SM14A403 SM16A463 SM17A503 SM14A469 SM16A538 SM17A585 SM14A526 SM16A604 SM17A657 SM24A619 SM26A746 SM27A811 SM24A797 SM26A915 SM27A995 SM24A882 SM26A1063 SM27A1155 SM24A1038 SM26A1192 SM27A1296 SM34A1123 SM36A1289 SM37A1402 SM34A1243 SM36A1498 SM37A1628 SM34A1463 SM36A1678 SM37A1824 SM44A1532 SM46A1846 SM47A1920 SM44A1829 SM46A2204 SM47A2281 SM44A2015 SM46A2428 SM47A2581 CAPACITY 10 F TD 31,400 37,800 41,000 40,300 46,300 50,300 46,900 53,800 58,500 52,600 60,400 65,700 61,900 74,600 81,100 79,700 91,500 99,500 88, , , , , , , , , , , , , , , , , , , , , , , F TD 47,100 56,700 61,500 60,450 69,450 75,450 70,350 80,700 87,750 78,900 90,600 98,550 92, , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,150 AIR FLOW (CFM) 9,860 8,980 8,550 9,690 8,810 8,390 9,510 8,480 8,100 9,330 8,400 8,000 19,700 17,900 17,100 19,380 17,600 16,800 18,890 16,900 16,100 18,400 16,800 15,900 28,600 24,900 24,700 28,000 24,600 23,700 27,400 24,400 23,500 33,900 33,200 32,930 33,400 32,800 31,600 33,000 32,530 31,330 MEDIUM TEMPERATURE FAN MOTOR AMPS / /3/50 380/3/60 460/3 L DIMENSIONS (IN) W H SHIPPING WGT. (LBS) ,070 1,090 1,034 1,156 1,175 1,100 1,235 1,255 1,280 1,430 1,455 1,380 1,540 1,565 1,470 1,645 1,670 Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTUH per fan to room load for SM units, or 6600 BTUH per fan to room load for SV units. Derate 12% for 50 Hertz (0.88 multiplier) or increase TD to compensate for lower fan RPM. 575/3 3
6 Electric Defrost High Profile SM MODEL SM14E384 SM15E426 SM16E440 SM14E501 SM15E556 SM16E574 SM24E759 SM25E842 SM26E869 SM24E989 SM25E1097 SM26E1132 SM34E1070 SM35E1186 SM36E1225 SM34E1393 SM35E1544 SM36E1594 *SM44E1465 *SM45E1523 *SM46E1754 *SM44E1769 *SM45E1985 *SM46E2307 SV14E422 SV15E468 SV16E664 SV14E550 SV15E611 CAPACITY 10 F 20 SST 38,400 42,600 44,000 50,100 55,600 57,400 75,900 84,200 86,900 98, , , , , , , , , , , , , , ,700 42,200 46,800 66,400 55,000 61,100 40,300 44,700 46,300 52,600 58,400 60,400 79,700 88,400 91, , , , , , , , , , , , , , , ,800 SV MODEL Low Temperature Only Below +30 F Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTUH per fan to room load for SM units, or 6600 BTUH per fan to room load for SV units. Derate 12% for 50 Hertz (0.88 multiplier) or increase TD to compensate for lower fan RPM. Insulated drain pan standard on Electric Defrost and Gas Defrost. *NOTE: Four fan SM/SV for low temperature requires two TEVs. LOW / MEDIUM TEMPERATURE AIR FLOW FAN MOTOR AMPS (CFM) /3 380/3/50 380/3/60 460/3 9,690 9,250 8,810 9,330 8,900 8,400 19,380 18,500 17,600 18,400 17,600 16,800 28,600 27,300 24,900 27,400 26,100 25,800 38,130 36,400 33,200 36,530 34,800 32,530 11,250 11,125 11,000 11,250 11, DIMENSIONS (IN) L W H SHIPPING WGT. (LBS) SV16E684 68,400 11, SV24E834 SV25E926 SV26E1005 SV24E1088 SV25E1206 SV26E1311 SV34E1177 SV35E1304 SV36E1418 SV34E1530 SV35E1698 SV36E1843 *SV44E1699 *SV45E1883 *SV46E2047 *SV44E2052 *SV45E2274 *SV46E ,400 92, , , , , , , , , , , , , , , , ,200 24,225 23,125 22,800 23,000 22,000 21,550 35,750 34,125 33,400 34,250 32,625 32,000 47,650 45,500 44,500 45,650 43,600 42, ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1, / ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1,
7 Hot Gas Defrost High Profile MODEL SM14( )384 SM15( )426 SM16( )440 SM14( )501 SM15( )556 SM16( )574 SM24( )759 SM25( )842 SM26( )869 SM24( )989 SM25( )1097 SM26( )1132 SM34( )1070 SM35( )1186 SM36( )1225 SM34( )1393 SM35( )1544 SM36( )1594 SM44( )1465 SM45( )1523 SM46( )1754 SM44( )1769 SM45( )1985 SM46( )2307 CAP. 10 F TD 20 SST 38,400 42,600 44,000 50,100 55,600 57,400 75,900 84,200 86,900 98, , , , , , , , , , , , , , , SST 40,300 44,700 46,300 52,600 58,400 60,400 79,700 88,400 91, , , , , , , , , , , , , , , ,800 LOW / MEDIUM TEMPERATURE AIR FLOW (CFM) 9,690 9,250 8,810 9,330 8,900 8,400 19,380 18,500 17,600 18,400 17,600 16,800 28,600 27,300 24,900 27,400 26,100 25,800 38,130 36,400 33,200 36,530 34,800 32,530 FAN MOTOR AMPS /3 380/3/50 380/3/60 460/ /3 DIMENSIONS (IN) L W H SHIPPING WGT. (LBS) ,030 1,050 1,060 1,195 1,215 1,240 1,370 1,340 1,400 1,469 1,540 1,600 NOTE: Available Types of Defrost: (P) KGE 2 Pipe Kool Gas with Electric Pan, (K) KGG 2 Pipe Kool Gas with Kool Gas Pan, (H) HGE 3 Pipe Hot Gas with Electric Pan, (G) HGG 3 Pipe Hot Gas with Hot Gas Pan. Insulated drain pan standard on electric defrost and gas defrost models. *NOTE: Four fan SM/SV for low temperature requires two TEVs. 5
8 Electric Defrost Heater Data MODEL COIL AND PAN E 230/3 380/3 AMPS KW AMPS KW 460/3 AMPS KW 575/3 AMPS KW 1 FAN 384, 426, 440, 501, 556, FAN 422, 468, 550, 611, 664, FAN 759, 842, 869, 989, 1097, FAN 834, 926, 1005, 1088, 1206, @42.2 1@ @16.8 1@ FAN 1070, 1186, 1225, 1177, 1304, FAN 1393, 1544, 1594, 1530, 1698, @42.2 1@3 1@16.8 1@ FAN 1465, 1523, 1754, 1699, 1883, FAN 1769, 1985, 2307, 2052, 2274, @40.7 1@14.3 2@16.2 1@5.7 1@32.8 1@2 1@21.6 1@ NOTE: Electric Defrost data shown as one circuit AMP draw, unless shown with two circuits (1@ and 1@) or three circuits (2@ and 1@) in the same space. MODEL PAN ONLY H AND P 230/3 380/3 AMPS KW AMPS KW 460/3 AMPS KW 575/3 AMPS KW 1 FAN 384, 426, 440, 501, 556, 574, 550, 611, 664, FAN 759, 842, 869, 989, 1097, 1132, 834, 926, 1005, 1088, 1206, FAN 1070, 1186, 1225, 1177, 1304, , 1544, 1594, 1530, 1698, FAN 1465, 1523, 1754, 1699, 1883, , 1985, 2307, 2052, 2274,
9 4 FINS PER INCH 4 FINS PER INCH 6 FINS PER INCH REFRIG. CHARGE MODEL SUCT. ODS (LBS) SM14* SM14* SM14* SM14* SM24* SM24* SM24* SM24* SM34* SM34* SM34* SM44* SM44* SM44* DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SM14** SM14** SM24** SM24** SM34** SM34** SM44** x x SM44** x x DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SM15** SM15** SM25** SM25** SM35** SM35** SM45** x x SM45** x x SM MEDIUM TEMPERATURE ROOM AIR DEFROST SM LOW TEMPERATURE ROOM ELECTRIC OR HOT GAS DEFROST 5 FINS PER INCH REFRIG. CHARGE MODEL SUCT. ODS (LBS) SM16* SM16* SM16* SM16* SM26* SM26* SM26* SM26* SM36* SM36* SM36*167A SM46* SM46* SM46* FINS PER INCH REFRIG. CHARGE MODEL SUCT. ODS (LBS) SM17* SM17* SM17* SM17* SM27* SM27* SM27* SM27* SM37* SM37* SM37* SM47* SM47* SM47* FINS PER INCH * A DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SM16** SM16** SM26** SM26** SM36** SM36** SM46** x x SM46** x x FINS PER INCH SV LOW TEMPERATURE ROOM ELECTRIC OR HOT GAS DEFROST 5 FINS PER INCH 6 FINS PER INCH DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SV14E SV14E SV24E SV24E SV34E SV34E SV44E x x SV44E x x DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SV15E SV15E SV25E SV25E SV35E SV35E SV45E x x SV45E x x DEFR. GAS REFRIG. F,G,H,K,M,P, CHARGE MODEL SUCT. ODS INLET (ODS) (LBS) SV16E SV16E SV26E SV26E SV36E SV36E SV46E x x SV46E x x "2x" indicates two connections per unit. ** E, G, H, K, or P. 7
10 Wiring Diagrams A, B, G, K, or R DEFROST H DEFROST (THREE PIPE HOT GAS DEFROST WITH ELECTRIC DRAIN PAN) EVAPORATOR FAN MOTORS EVAPORATOR FAN MOTORS DRAIN PAN HEATERS HEATER SAFETY THERMOSTAT HEATER CONTACTOR DEFROST DURATION FAN DELAY THERMOSTAT FAN MOTOR CONTACTOR TRANSFORMER (IF REQUIRED) MOTOR POWER SUPPLY POWER SUPPLY FACTORY WIRING FIELD WIRING P DEFROST (TWO PIPE KOOLGAS DEFROST WITH ELECTRIC DRAIN PAN) E DEFROST (ELECTRIC DEFROST) EVAPORATOR FAN MOTORS EVAPORATOR FAN MOTORS DEFROST HEATERS DRAIN PAN HEATERS DRAIN PAN HEATERS (IF E UNIT) MOTOR POWER SUPPLY HEATER CIRCUIT POWER SUPPLY MOTOR POWER SUPPLY HEATER HEATER CIRCUIT #1 CIRCUIT #2 POWER POWER SUPPLY SUPPLY (IF REQ D) DEFROST DURATION FAN DELAY THERMOSTAT 8
11 Dimensional Data 11/16 DIA. MOUNTING HOLES ACCESS DOOR (BOTH SIDES) ELECTRICAL KNOCKOUTS STANDARD FAN GUARD DISTRIBUTOR INLET CONN. OPTIONAL AIR THROW BOOSTER AIR FLOW DRAIN PAN 1.25 FPT DRAIN CONNECTION SUCTION CONN. UNIT DIMENSIONS SIZE A B C D E 1 FAN @ FAN @ FAN @ FAN @ Note: Dimensions in inches. 9
12 Use your QR reader to reference current document version on Krack, a Hussmann Corporation brand 890 Remington Boulevard Bolingbrook, Illinois Ph: Printed in U.S.A Krack, a Hussmann Corporation brand SMSV_005_040517
SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse
More informationMS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.
MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.
H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions. H and GH/G SERIES UNIT COOERS H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height,
More informationKR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.
KR Series COMPACT UNIT COOERS Technical Bulletin: KRUC_00_07 Products that provide lasting solutions. Provides Excellent Design Innovations That Enhance Overall Refrigeration Performance The KR Compact
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationLevitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)
Levitor II AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications) Technical Bulletin: LEVE_002_103116 Products that provide lasting solutions. Table
More informationLow Profile Unit Coolers
CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits
More informationLOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,
CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More informationLow Profile Unit Coolers
BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...
More informationSM/SV-Space Master Unit Coolers (E R.0)
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008 R.0) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationLow Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.
LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationSlim Contour Unit Cooler
Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim
More informationKTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationSM/SV Series Space Master Unit Coolers Operating and Installation Manual
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008_G) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationBTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature
More informationLow Flow Unit Coolers
BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3
More informationBN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide
BN-HGDTB June 2017 Replaces BN-HGDTB, March 2011 Mohave Technical Guide Table of Contents Overview... 2 System Features... 3 Condensing Unit... 4-18 Mohave Hot Gas Defrost Quick Reference... 5 AWEF Ratings...11
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationLow Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional
Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000
More informationKTL Two-Way Low Profile Unit Coolers
PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical
More informationCompak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)
Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now
More informationSPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION
SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationToday s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.
Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features
More informationKR Electrical Defrost Unit Coolers (PN E108318_E)
KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN
More informationToday s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.
Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features
More informationTLV Low Velocity Evaporators
PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature
More informationReach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June
LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3
More informationAir-Cooled Condensers
CH-RACCTB APR 2015 Replaces CH-RACCTB April 2011 Air-Cooled Condensers Technical Guide Models WSS Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional Data...5
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationCR1 Series Triton Corrosion Resistant Washdown Heaters
CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging
More informationCHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS
550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.
More informationTECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT
TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationIndustrial Unit Coolers
HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and
More informationPage ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018
` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationPage ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18
` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationUnit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products
PRUCT CATALOG Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products peerlessofamerica.com Welcome to Peerless of America II Peerless of America II Inc. was founded in 1912
More informationRefrigeration Systems by. Cool You Can Count On!
Refrigeration Systems by Cool You Can Count On! www.ref-sys.com Keeping Storage Cool... Refrigeration Systems (RSI) has provided engineered cooling systems to agricultural refrigeration markets and vegetable
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationLK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.
LK-TSSTB July 2009 FPO 5-30 HP Two Stage Condensing Units and Systems Technical Guide with Bitzer s www.larkinproducts.com Table of Contents Standard Features... 2 Nomenclature... 2 Condensing Unit Capacity...
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationCONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00
BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from
More informationAir-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV
LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationRLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES
` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationUnit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60
Unit Dimension Unit Nomenclature DEHUMIDIFIER NOMENCLATURE R K D A - 0050 - C Z - M 4-8 UNIT VOLTAGE: 2: 240/1/60 5: 208-240/3/60 9: 480/3/60 8: 600/3/60 REFRIGEREANT R-404a MEDIUM TEMPERATURE SCROLL COMPRESSOR
More informationKramersaver Air Cooled Condensing Units
Catalog KM-KSX-0613A Kramersaver Series Kramersaver Air Cooled Condensing Units Models C & KS 4 through 70 HP Kramer C and KS model condensing units are available in 4 to 70 HP. While the basic C model
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationNH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN
NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin K40-THERM-PDI-15 Part # 1069130 PRODUCT SUPPORT web: k-rp.com/ts email: mdcu-lgcu@k-rp.com
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More informationKR Series Air Defrost Unit Coolers Operating and Installation Manual
KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING
More informationAir-Cooled Condensers
BN-RACCTB Sept. 2016 Replaces BN-RACCTB April 2015 Air-Cooled Condensers Technical Guide Models DVT Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationFX5 Series Explosion-Proof Electric Air Heaters
FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationcommercial refrigeration products
commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationSTC Series Twin Unit Coolers (E329630_A)
STC Series Twin Unit Coolers Operating and Installation Manual STC Series Twin Unit Coolers (E329630_A) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING CHARGE 3 2 ASSEMBLY
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationSPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES
AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationModel PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,
AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA-
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationSubmittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:
Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationDT/DTX Series Unit Coolers (R0 E316013)
DT/DTX Series Unit Coolers Operating and Installation Manual DT/DTX Series Unit Coolers (R0 E316013) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING CHARGE 3 2 ASSEMBLY
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More information