Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02
|
|
- Reynard Shaw
- 6 years ago
- Views:
Transcription
1 Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02
2 Contents Notes... 3 Safety and handling... 4 Operation... 5 Technical data... 6 Pipe installation... 8 System principle Expansion vessel Safety valve Filling - bleeding Flow - bypass valve Circulation pump Pump capacity Display Indication Pump operation Electrical installation Power supply The boiler can be connected as follows: 1.5 kw / 230 V~ / 6.5 A 2.25 kw / 400 V 2N~ / 5.6 A 3.0 kw / 400 V 2N~ / 7.5 A 4.5 kw / 400 V 3N~ / 6.5 A External block/room thermostat Connecting the UTK 2000, accessory Wiring diagram Operation and care Control panel Temperature settings Safety valve Overheating protection If there is a risk of freezing Thermometer Expansion vessel Water pressure in the system Bleeding Draining Troubleshooting Components
3 Notes To be completed when the MP 4 is installed! Serial number:... Installation date:... Installer:... Tel:... Connection: 1,5 kw /230V~ 2,25 kw / 400V 2N~ 3,0 kw /400V 2N~ 4,5 kw / 400V 3N~ Other:
4 Safety and handling Read these instructions carefully before installation, adjustment or service is carried out. Keep the instructions close to the boiler. Check that the delivery is complete. All installation must be performed by an authorised person in accordance with the existing regulations. Only authorised persons may work on the system. Correct installation in combination with correct adjustment and continuous service will produce high operational reliability and good heating economy. Use only original spare parts. Spare parts that do not meet Värmebaronen's specifications may have an impact on safety. Always contact your installation engineer for service. The type and serial number of the boiler must always be specified when ordering spare parts. See the rating plate. This product is not designed to be used by persons with reduced physical or mental capacity or a lack of experience and knowledge unless they are supervised or instructed by a person with responsibility for their safety. Children must be instructed/supervised to ensure that they never play with the product. Värmebaronen AB reserves the right to change the specification, in accordance with its policy of continuous improvement and development, without prior notice. Subject to amendments and printing and proofreading errors. The following icons are used in these instructions to indicate important information: Information that is important for optimum operation. Tells you what you should or should not do to avoid personal injury. Tells you what you should or should not do to avoid the product, a component, a process or the environment from being damaged. The boiler must not be modified, changed or converted in any way. Electrical hazard! Never disable the safety equipment! Before service and maintenance work are started, the system must be disconnected from the main power supply. 4
5 Operation Compact MP 4 is small in size, with a discreet cover making it easy to find a space for. Many possible uses MP 4 is a wall-mounted electric boiler with a stainless steel container. The boiler has many possible uses for example underfloor heating in extensions or conservatories, or an easy way to heat your holiday cottage or detached garage. The MP 4 can also be used for portacabins, holiday chalets and on camp sites. The possible applications are endless. Separate systems are better If you have underfloor heating, it is better to have separate systems for heating and hot water. This means that the temperature of the hot water is independent of the temperature of the underfloor heating system (usually 25-40ºC). Powerful The boiler has the power to meet the heating requirement for a domestic surface area of 100 m², subject to insulation and ventilation. Depending on how it is connected, the boiler can supply 1.5, 2.25, 3 or 4.5 kw. The boiler is controlled by an onboard thermostat. Complete The MP 4 is supplied complete. Once the water and electricity are connected, it is ready to use. The boiler is equipped with: - thermostat - overheating protection - indicators showing power on and overheat protection triggered - control switch - circulation pump - expansion vessel - pressure gauge - thermometer - safety valve, 2.5 bar - automatic bleed valve - bypass valve Accessories UTK 2000: outdoor temperature compensation to adjust the boiler depending on the outdoor temperature, product no. 1920, RSK Room thermostat, 7-30 C product no
6 Technical data MP 4 product no: 2037 Power options kw Voltage V~ Phases 1+N 2+N 2+N 3+N Current A Fuses 10 2 x 10 2 x 10 3 x 10 A Protection class IP x1 Power, circulationpump 2-34 W Volume, boiler 5.5 litre Volume, expansionvessel 2 litre Design pressure 2.5 bar Test pressure 3.6 bar Safety valve 2.5 bar Design temperature 80 C Temperature range C Weight 17 kg Manufactured to AFS 1999:4 8 97/23/ECArticle 3 Without cover With cover
7 Technical data Circulation pump 15. Flow pipe, R20 ext. 16. Return pipe, R20 ext. 17. Bypass with shut-off valves. 18. Safety valve. 19. Expansion vessel. 20. Bleed valve. 21. Stainless steel container, insulated, with immersion heater. 22. Protective cover for immersion heater wiring. 23. Cable penetrations. 24. Knockout for cables if they lead from the wall. 25. Collecting vessel, waste water from safety valve. 26. Sensor clip, thermometer bulb. 27. Protective cover. 7
8 Pipe installation The installation must comply with the applicable regulations and standards. The boiler is designed for indoor use, fixed to the wall or similar support with the pipes connected underneath. The ambient temperature must not exceed 30 C. The clearance underneath the boiler must be at least 300 mm to allow the immersion heater to be changed if necessary. Hard water with a high mineral content is not suitable for HVAC applications. To avoid corrosion, the ph value should not be too low. The venting pipe from the boiler safety valve leads to a drip collector within the boiler. The applicable regulations state that an installation inspection must be carried out on a system with a sealed expansion vessel, before it is put into operation. The inspection must be carried out by a person qualified for the task. A further inspection is required if any parts or the expansion vessel are replaced. Clamps must be used when the connections are made to prevent damage to the internal pipework. System principle The diagram below illustrates the system principle the actual system must be designed according to the applicable regulations and standards. Expansion vessel Expansion vessel: 2 litres, pressured on delivery to 1.5 bar. The expansion vessel can handle a heating system volume of 70 litres at 60 C and a static head of 5 metres. If the static head or the temperature is lower, the expansion vessel can handle a larger volume. If glycol is added, the capacity of the expansion vessel falls in relation to the quantity of added glycol. Safety valve The safety valve, 2.5 bar, is fitted to the boiler and the venting pipe leads to a drip collector within the boiler. Filling - bleeding The heating system must be filled with water to a pressure that is higher that the initial pressure of the expansion vessel, 1.5 bar. 2 bar is recommended. When the system is filled with water, it must be bled at the electric boiler and at the pipe manifold. Flow - bypass valve A reliable flow must be guaranteed, the boiler require a flow of 6.5 liters / min which gives a t at most 10 C. The bypass valve should be open between turns. If the valve is: - Too little open, the pump may be damaged and the risk increases to overheat protection should trip. - Too much open, the circulation in the heating system become too small. D A Adjusting valve, unscrew the protective cover for access. C B A. MP 4 electric boiler, including: safety valve, expansion vessel, circulation pump, pressure gauge, bleed valve, and bypass with shut-off valves. B. Filling/drain valve. C. Shut-off/flow control valves. D. Underfloor heating system. Shut-off valves, flow and return to boiler. 8
9 Pipe installation Circulation pump Delivery setting: Constant pressure curve 1. If parts of the heating system does not get hot, this may need to be changed to Constant pressure curve 2. Election of a higher curve increases energy consumption and operating cost. Push bottom LED indications When the pump is running, LED 1 is green. The four yellow LEDs indicate the current power consumption as shown below % If LED 1 is red, it indicates alarm or warning. Display Indication Pump operation Rotor is blocked. Red + one yellow Red + one yellow Red + one yellow (LED 3) Supply voltage too low. Electrical error. Trying to start again every 1.5 Only warning, pump runs. Pump is stopped because of low supply voltage or serious failure. Counter action Wait or deblock the shaft. Control the supply voltage. Control the supply voltage /Exchange the pump % % % Pressing the push button shows which mode controls the pump. After 2 seconds, the display switches back to performance view. Key lock function If you press the key lock for more than 10 seconds, you can toggle between enabling/disabling the key lock function. When doing so, all LEDs, except for the red LED, will flash for a second indicating that lock is toggled. Pump capacity PROP. PRESS.: CURVE 1 PROP. PRESS.: CURVE 2 PROP. PRESS.: CURVE 3 p [kpa] H [m] CONST. PRESS.: CURVE 1 CONST. PRESS.: CURVE 2 CONST. PRESS.: CURVE 3 CONST. CURVE: CURVE 1 CONST. CURVE: CURVE 2 CONST. CURVE: CURVE Q [m³/h] 0.0 P Q [l/s] [W] Q [m³/h] CONST. CURVE: CURVE 4 Pressing the button for 2 seconds switches to "setting selection". You can change the settings as they appear. The settings appear in a particular order in a closed loop. When releaseing the button, the user interface switches back to the performance view and the last setting is stored. 9
10 Electrical installation Electrical installation must be in accordance with the applicable regulations, under the supervision of an authorised installer.stallatör kw / 400 V 2N~ / 5.6 A Supply cable: 4 x 1.5 mm 2 Fuse: 2 x 10 A The boiler must not be connected to the power supply before it is filled with water. An all-pole circuit breaker must be installed ahead of the boiler. The ambient temperature must not exceed 30 C. 1 3 P X N N L3 L2 L1 Power supply Terminal block Protective cover 3.0 kw / 400 V 2N~ / 7.5 A Supply cable: 4 x 1.5 mm 2 Fuse: 2 x 10 A Jumper: N - X The boiler has two power settings: 1.5 and 3 kw. 1 3 P X N N L3 L2 L1 Knockout (cables from wall Cable penetrations In a single or two phase connection, the boiler will not act on all the main fuses. Other large consumers should therefore be connected to the phases that are not acted on by the boiler. 4.5 kw / 400 V 3N~ / 6.5 A Supply cable: 5 x 1.5 mm 2 Fuse: 3 x 10 A The boiler has two power settings: 2.25 and 4.5 kw. At 2.25 kw, only phases L1 and L2 (5.6 A) are loaded. 1 3 P X N N L3 L2 L1 The boiler can be connected as follows: 1.5 kw / 230 V~ / 6.5 A Supply cable: 3 x 1.5 mm 2 Fuse: 10 A Jumper: N - X 1 3 P X N N L3 L2 L1 External block/room thermostat The boiler can be blocked by an external device, for example a room thermostat with a voltage-free contact. There is normally a jumper between terminals 1-3 in the terminal block, 230 V~ P X N N L3 L2 L1 10
11 Electrical installation Connecting the UTK 2000, accessory For more details, refer to the instructions for the UTK MP P X N N L3 L2 L1 UTK 2000 Wiring diagram 6 80 C T C T 41 7 L4 T kw L3 T L1 L1 T2 T1 3 4 N 5 N A1 Alarm LARM N DRIFT 10 N Operation A2 N N 1 3 P X N N L3 L2 L External block. 2. Jumper setting for 1.5 and 3 kw connection. 3. Terminal block. 4. Protective capacitor. 5. Circulation pump. 6. Overheating protection. 7. Thermostat. 8. Immersion heater. 9. Control switch. 10. Alarm indicator, overheat protection triggered. 11. On/off indicator, lights up when the boiler connected to the mains. 12. Contactor. Interventions requiring tools can only be carried out under the supervision of an authorised installer. Electrical hazard! 11
12 Operation and care Control panel Temperature settings Set the thermostat to a suitable temperature. The maximum temperature for a concrete floor is about 30 C and for a wooden floor it is about 40 C. The temperature requirement varies according to the time of year Min. 0,5 Bar Max. 2,5 Bar 6 10 Safety valve The safety valve must be exercised regularly in order to maintain the safety function C 9 Tillse att pannan är vattenfylld innan den startas Boiler must be filled with water before start 6. Overheating protection reset. 7. Thermostat/temperature setting. 9. Control switch. 10. Indicator showing triggered overheating protection. 11. On/off indicator, lights up when the boiler connected to the mains. 13. Manometer. 14. Thermometer. After installation, check with the installer that the system is in perfect working order. Ask the installer to demonstrate how to operate and care for the system. The boiler and the heating system must be filled with water before the switch is set to on. The boiler cover must be fitted while the boiler is running. Overheating protection The overheating protection in the boiler is triggered when the boiler temperature exceeds 80 C. You can reset the device from the control panel after the boiler temperature has fallen to below 65 C. Call the installer. If there is a risk of freezing If the system will be turned off for an extended period, think about the risk of freezing. All the water in the system must be drained if there is a risk of freezing, and the power supply to the boiler must be cut. Alternatively, the correct quantity of antifreeze can be added to the heating system. The boiler must not be put into operation if any part of the heating system is suspected of being frozen. Call the installer. Always check the reason for overheating. Thermometer The thermometer shows the temperature on the flow side of the boiler. Expansion vessel The initial pressure of the expansion vessel must be checked annually, see the data plate on the expansion vessel. Regularly check the amount of water in the drip collector for the waste water from the safety valve. Important in a new system. Water pressure in the system The boiler cover has to be removed in order to check the pressure. The pressure gauge shows the pressure in the heating system. Regularly check that there is sufficient water in the system. 12
13 Operation and care The pressure gauge must read bar. The volume of water changes with the temperature, and this affects the pressure. The higher the temperature the greater the volume and the higher the pressure. The expansion vessel takes up the changes in volume. Check the water pressure in the system regularly. Bleeding Air may remain in the system for a while after installation, so water may need to be added. Draining Before the water is drained from the system, the electric boiler must be switched off. Always disconnect the power supply to the boiler before: draining the boiler water accessing the automation cabinet or units powered by the boiler 13
14 Troubleshooting Problem Possible cause Solution On/off indicator off, no heat in No power to electric boiler. Check the fuses. heating system. Switch set to off. Check that the main and control switch are set to on. Boiler externally blocked. Check whether the immersion heater is being blocked by an external block/room thermostat. Alarm indicator on. Overheating protection triggered. If the overheating protection is triggered, you must check the operation of the circulation pump and valves. To reset, press the button on the overheating protection after the boiler temperature has fallen to below 65 C. Always check the reason why the overheating protection triggered call the installer. No heat or not enough heat. The valves in the heating system Check and adjust. or boiler thermostat are set too low. Incorrectly adjusted bypass Check and adjust. valve. Group fuses for the boiler triggered. Immersion heater faulty. Check the immersion heater by doing an insulation test. Take measurements between the outgoing side of the contactor and earth. Call the installer. Interventions requiring tools can only be carried out under the supervision of an authorised installer. 14
15 Components Ref. Prod.no. Name Qty Immersion heater 4.5 kw Cable entry Ø17.5 mm Cable entry 16 mm Klingersil gasket R Nut G Housing 2 x G20, 2 x G15, 1 x G Bleed valve Hose fitting, swivel H-Bypass Safety valve 2.5 bar Circulation pump Expansion vessel Insulation O-ring, immersion heater Plastic plug, blue Plastic plug, red Collecting vessel /2" hose, coupling Velcro strip Flow pipe Return pipe End gasket Electrical cabinet, complete Thermostat knob Overheating protection Thermostat,10-60 C Switch 1 Ref. Prod.no. Name Qty Cable entry Ø35 mm Set of cables, complete Terminal block, 12-pole End plate for terminal block Jumper, 2-pole Jumper, 3-pole Contactor LED, orange LED, red Plastic lock plug Manometer, 0-4 bar Thermometer C Protective capacitor X Panel overlay Installation plate Sensor clip Support 18 mm Container Holder for expansion vessel Lower support Pipe holder, front Cover Base plate Pipe holder, upper Cover, immersion heater Protective cover 1 15
16 Masterwatt Reeweg AP Hendrik-Ido-Ambacht T: +31 (0)
LK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More informationInstallation, operation and care. Pellmax UB. Burner not included Replaces:
Installation, operation and care Burner not included 2011-11-11 ver: Replaces: Contents 11.11 otes...3 General...4 Function...4 Technical data...5 System principle Pellmax with radiator and tank-in-tank
More informationTechnical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw
Technical Guide Installation, Operation and Care EP E series 7 step electric boilers 26 and 42 kw Arkelstorpsvägen 88, 291 94 KRISTIANSTAD Tel +46 44-22 63 20, Telefax +46 44-22 63 58 e-mail: info@varmebaronen.se
More informationGB24 & GB30. User Manual
GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features
Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The
More informationInstallation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:
Installation, operation and maintenance Accumulator tank Acc-tank 500 CU 2010-11-2 ver: Supersedes: Acc-tank General information 1011 Read through these instructions carefully before carrying out installation,
More informationCROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15
CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm
More informationSIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A
cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationSolar station DKP 6-8 / DKP Installation and Service Manual C
EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationInstaller manual ELK 213 Immersion heater
Installer manual ELK 213 LEK IHB GB 1535-3 031403 Table of Contents 1 English, IHB - ELK 213 General Component positions Pipe connections 2 2 3 5 Disturbances in comfort Accessories Technical data Electrical
More informationInstallation, operation and care Firewood boiler Vedolux 40 UB
Installation, operation and care Firewood boiler Vedolux 40 UB 2008-09-23 Ver 2 Replaces: 05-11 VEDOLUX 40 UB Notes 0809 To be completed when the Vedolux 40 UB is installed Serial number:... Installation
More informationLogic+ Combi
USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use
More informationFIL-SPL Flow-through heater for central heating USER MANUAL
FIL-SPL Flow-through heater for central heating with 0-10 V EP 15-30 control unit USER MANUAL Kaukora LTD. D106159 r3.0 Contents 1. Important information... 5 Safety information... 5 General... 5 Marking...
More informationBOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration
in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation
More informationZip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water
Installation and Operating Instructions Zip Hydroboil Filtered instant boiling water 01552 Zip Hydroboil 1.5 Litre White 01551 Zip Hydroboil 1.5 Litre Stainless Steel 03552 Zip Hydroboil 3 Litre White
More informationInstallation, operation and maintenance instructions. HRi Y1300-A
Installation, operation and maintance instructions HRi 321-601 - 800 Table of contts Geral Recommdations...4 User's Guide...5 Control Panel... 5 Appliance Description...6 Models - HRi 321 601-800... 6
More informationZip Autoboil Installation and Operating Instructions
Zip Autoboil Installation and Operating Instructions 315052 Zip Autoboil 15 Litre White 313051 Zip Autoboil 15 Litre Stainless Steel 325052 Zip Autoboil 25 Litre White 325051 Zip Autoboil 25 Litre Stainless
More informationAGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water
Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is
More informationFITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS
TRIANCO Electric System Boiler KM 59690 FITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS To be retained by the householder HEALTH AND SAFETY INFORMATION FOR THE INSTALLER AND SERVICE ENGINEERS
More informationUnvented Electric Water Heater 10/15 litre Undersink
Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9
More informationELECTRIC BOILERS FOR CENTRAL HEATING
ELECTRIC BOILERS FOR CENTRAL HEATING TermoMax INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations WE ARE NOT LIABLE FOR DAMAGES RESULTING FROM NON- OBSERVING
More informationMULTI ELEC. Electric Boilers TECHNICAL MANUAL
MULTI ELEC Electric Boilers TECHNICAL MANUAL PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) 161 621 5960 Fax +44. (0) 161 621 5966 info@atlantic2000.co.uk www.atlanticboilers.com 2 CONTENTS DESCRIPTION....
More informationADVANCE ECB ELECTRIC COMBINATION BOILER
ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationUSERS GUIDE. LOGIC+ Combi 24, 30, 35
USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use
More informationTECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:
TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS,
EN INSTALLATION, OPERATION AND MAINTENANCE INSTCTIONS, for the User and the Installer HR i 320-600 - 800 A1002237-661Y1300 B EN EN TABLE OF CONTENTS GENERAL RECOMMENDATIONS...3 PRODUCT INFORMATION...4
More informationINSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15
INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 01 CONTENTS Special information 2 General information 3 Safety 5 Appliance description, cleaning, care & maintenance 7 Appliance
More informationMIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS
TCHNICAL SPCIFICATION DSCRIPTION Thermostatic mixing kit with micrometric valve with thermostatic option, circulation pump (rp Ready 641/2009/C - 622/2012/C), balancing lockshield and couple of manifolds
More informationSEALED THERMAL STORE
ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL
More informationInstallation and User Instructions HS10U, HS15U.
Installation and User Instructions HS10U, HS15U. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation PACK CONTENTS
More informationSATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE
780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of
More informationInstallation and Maintenance Manual Please retain this manual for future reference.
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters
More informationComponents for solar heating systems
solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised
More informationInstallation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump
Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality
More informationCombi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER
Combi C30 & C35 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER When replacing any part on this appliance, use only spare parts that you can be assured confirm
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS, for the User and the Installer. SMART Line. Smart ME A Y2000 B
INSTALLATION, OPERATION AND MAINTENANCE INSTCTIONS, for the User and the Installer SMART Line Smart ME 00-300 - 400-600 - 800 A00859-66Y000 B TABLE OF CONTENTS GENERAL RECOMMENDATIONS...4 PRODUCT INFORMATION...5
More informationSMART Line Smart E
INSTALLATION, OPERATION AND MAINTENANCE INSTCTIONS, for the User and the Installer SMART Line 30-60 - 20-240 - 300 Plus 20-240 - 300 A002858-66Y200 B TABLE OF CONTENTS GENERAL RECOMMENDATIONS...4 PRODUCT
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationUSER GUIDE VOGUE MAX SYSTEM
USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationUSER GUIDE LOGIC HEAT H
USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationInstallation, Operating and Servicing Instructions
ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions
More informationEDENA CLASSIC E. Model : kw INTALLATION AND SERVICING INSTRUCTIONS. Gas Fired Floor Standing Boiler. Réf. : CH I EN 09/05
INTALLATION AND SERVICING INSTRUCTIONS EDENA CLASSIC E Model : 35-43 - 53-64 kw Gas Fired Floor Standing Boiler N04266.DSF Réf. : CH - 1254 - I - 0 - EN 09/05 1 Réf. : CH - 1254 - I - 0 - EN Contents 1.0
More informationAlpha CombiMax 350 and 600
Installation and Servicing Instructions Alpha CombiMax 350 and 600 Unvented Hot Water Store for use with the Alpha 240/280 Range of Gas Fired Combination Boilers For Technical help or for Service call...
More informationDIGITAL MODULATING BOILERS
DIGITAL MODULATING BOILERS FOR HEATING AND SANITARY HOT WATER CMX15 CMX18 CM15 CM18 INSTALLATI INSTRUCTIS AND USER GUIDE Please read these instructions before installing or using this appliance for the
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationUSER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book
USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationUSERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book
USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationSamsung EHS Heat Pump Test
Samsung EHS Heat Pump Test The following questionnaire is designed for installers who have experience with heat pumps, are currently MCS accredited, and who want to fast track their Samsung accreditation
More informationHEAT ONLY & COMBI BOILER
Spare Parts Catalog Riva Plus HEAT ONLY & COMBI BOILER M135.30 CM / M135.30 CR Prepared by: QHT, Inc. Portsmouth, NH 603-334-6400 phone www.qhtinc.com Rev: 06.23.09 1 06/09 2 06/09 TABLE OF CONTENTS Description
More informationZip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.
Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens. 103592 Zip Econoboil 3.0 litre White HS503 105592 Zip Econoboil 5.0 litre White HS505
More informationInstallation, Operating and Servicing Instructions
EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards
More informationIMPORTANT SAFETY INSTRUCTIONS
User Manual INDEX IMPORTANT SAFETY INSTRUCTIONS... 1 FEATURES... 2 SPECIFICATIONS...2 PRODUCT DESCRIPTION... 3 THE CONTROL PANEL... 4 UNIT SETUP... 5 TO OPERATE SAFELY... 5 OPERATING INSTRUCTIONS... 6-10
More informationFRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE
FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE Introduction Thank you for purchasing this Franke product, which has been designed and manufactured to the highest quality standards.
More informationInstallation & Technical Guide. Domestic & Commercial.
Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower
More informationMulti-Elec COMPACTE BOILER
Multi-Elec COMPACTE BOILER TECHNICAL MANUAL 03/2013 CODE: 560956 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) FOR TECHNICAL HELP/ADVICE Call 0161 621 5960 or email info@atlanticboilers.com
More informationUSERS GUIDE 24, 30. For installation guide see reverse of book
USERS GUIDE 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification
More informationFHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P
FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure
More informationSolar heating systems
03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back
More informationSwedish design and manufacture since 1967
Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationSEISCO APPLICATIONS & DIAGRAMS
ALICATIONS & DIAGRS A. Seisco Selection Criteria B. Residential Floor lan Diagrams 1. Standard One Story Home Options 2. Standard Two Story Home Options 3. One Story Booster for Quicker Response C. Application
More informationSystem s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER
System s30 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER When replacing any part on this appliance, use only spare parts that you can be assured conform to the
More informationRecirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual
Recirculating Chiller RC350G-RC400G RC1400G-RC3000G Operating Manual Part No 09931/Issue 10 Page 2 April 2010 CONTENTS 1 Safety 4 2 Installation 5 2.1 Connection for closed loop circulation 6 2.2 Connection
More informationInstallation and User Guide Please leave this guide with the end user (for future reference)
Contact and Commissioning Details Installer Contact Name and Address : Model N : Serial N : Date Installed : Installation and User Guide Please leave this guide with the end user (for future reference)
More informationMercury Mixing Kit (Code: ME1053)
Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or
More informationAQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide
AQUA PREMIER ELECTRONIC ELECTRIC SHOWER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration CONTENTS Section Page Section Page Introduction.......................
More informationSPECIFICATIONS - NIKE
Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks
More informationPowermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage
User s Instructions Quick Guide to the Controls When the Powermax was installed, the Installer should have - left or given you these and other instructions including the Benchmark Log Book and Potterton
More informationSolar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.
Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material
More informationADVANCE ELECTRIC THERMAL STORE
ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal
More informationOPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"
OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationNIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication
NIBE VVM 300 all in one indoor unit Intelligent hot water VVM 300 is designed for connection and communication with outdoor heat pump F20XX of 6 kw, 8 kw and 10 kw. Water volume 280 litres, of which 155
More informationHIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler
HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55
More informationElectronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user
Electronically controlled instantaneous water heater CEX 9 CEX9: 27900-50 C models Instructions for the user For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498.
More informationUSER GUIDE VOGUE COMBI GEN2 C26 C32 C40
USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationInstallation and Operating Instructions. Budget priced instant boiling water heater for beverages.
Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water heater for beverages. Model No. Description Reg.No. Part No. HS503 Zip Econoboil 3.0 litre White EB003 103592 HS505
More informationCooler Manual XRC-3012-WA 3000 Watt water to air cooler
Industrial X-Ray Cooler Manual XRC-3012-WA 3000 Watt water to air cooler XRC-3012-WA, Doc.-No. 50005645 Page 1 of 13 Document history Version Date Author Amendment(s) Status 12/15/2008 St. Haferl released
More informationWall hung combination boiler PROTHERM 23 BTVE
Wall hung combination boiler PROTHERM 23 BTVE User, Installation and Servicing Instructions 6187 The boiler serial number is marked on the label attached to the inside of the drop down door. Refer to the
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS,
INSTALLATION, OPERATION AND MAINTENANCE INSTCTIONS, for the User and the Installer EN SMART Line SL 320-420 - 420 Duplex - 600 A002875-66Y300 A EN TABLE OF CONTENTS GENERAL RECOMMENDATIONS...4 Energy labelling...
More informationSATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production
SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface
More informationOWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.
OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat
More informationHEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater
HEATRAE SADIA The quality name in water heating Installation and User Instructions for the UTC Undersink Vented Water Heater UTC 15 Please read and understand these instructions before starting work. Please
More informationOperating instructions Oil condensing boiler
Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet:
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS R8215343-02EN - Edition 02-01/04/2007 Domestic Gas Boilers MICROGENUS PLUS 537814 MICROGENUS PLUS 24 MET...... 3300078 MICROGENUS PLUS 21
More informationPowerstock Storage Tank
Powerstock Storage Tank Models ST300, ST500, ST750 & ST1000 INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS THE POWERSTOCK STORAGE TANK IS INTENDED FOR USE AS A COMMERCIAL APPLIANCE. PUBLICATION
More informationUSERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC
keeping your home safe and clean USERS MANUAL Desiccant Dehumidifier Model: ECO DD322FW CLASSIC Read This Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationSpare Parts Guide & Price List
Spare Parts Guide & Price List October 0 www.zipheaters.co.uk Contents On Wall Instant Boiling Water Zip Hydroboil HG00 HG00 Zip Hydroboil HS00 HS00 Zip Hydroboil Plus HS0 HS0, HS0 HS0 Zip Hydroboil Plus
More informationServicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use
GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents
More informationDescription of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
More informationElectrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)
Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?
More informationHeat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER
Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions
More information