1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS September 4 TECHNICAL DATA BOOK <Indoor unit> [Model Name] INVERTER PLA-SP BA PEAD-SP JA PEAD-SP JAL RA No. OCS <Outdoor unit> [Model Name] PUHZ-SP/5/VHA PUHZ-SP/5/YHA CTENTS. REFERENCE MANUAL.... SPECIFICATIS.... OUTLINES AND DIMENSIS WIRING DIAGRAM REFRIGERANT SYSTEM DIAGRAM PERFORMANCE CURVES CORRECTI FACTORS APPLICABLE EXTENSI PIPE FOR EACH MODEL AIR FLOW DATA NOISE CRITERI CURVES.... OPTIAL PARTS... 8 kw Model

2 REFERENCE MANUAL For information on service, please refer to the service manual as follows. -. INDOOR UNIT SERVICE MANUAL Model Name PLA-SP/5/BA PEAD-SP/5/JA PEAD-SP/5/JAL Service Ref. PLA-SP/5/BA.UK PEAD-SP/5/JA.UK PEAD-SP/5/JAL.UK Service Manual No. OCH565 OCB565 HWE BWE8 -. OUTDOOR UNIT Model Name PUHZ-SP/5/VHA PUHZ-SP/5/YHA Service Ref. PUHZ-SP/5/VHA.UK PUHZ-SP/5/YHA.UK Service Manual No. OCH566 OCB566 OCS

3 SPECIFICATIS -. CEILING CASSETTE TYPE Model Name Indoor unit PLA-SPBA PLA-SP5BA PLA-SPBA Outodoor unit PUHZ-SPVHA PUHZ-SP5VHA PUHZ-SPVHA Cooling Capacity BTU/h, 4, 46, kw 9.4 ( ). (5.5.). (5.5 4.) Total input kw EER..6 Energy label class B D SHF Design load kw 9.4 Annual electricity consumption* kw h/a 644 SEER 5. Energy efficiency class A Heating Capacity BTU/h 8, 47,8 54, kw. (4.5.5).5 (5. 5.) 5.5 (5. 7.) Total input kw COP.4. Energy label class B C Design load kw 8. Decrared capacity at reference design temperature 6. ( :) at bivalent temperature 7. ( 7:) at operation limit temperature 5. ( 5:) Backup heating capacity.7 Annual electricity consumption* kw h/a 945 SCOP.8 Energy efficiency class A Power supply Phase { Cycle Hz Voltage V Breaker size A Indoor unit Air flow CMM (-Medium-Medium-) CFM External pressure Pa Sound level db(a) (-Medium-Medium-) External finish (Panel) White Munsell 6.4Y 8.9/.4 Unit (Panel) Dimension Notes:. Rating conditions (ISO T) Cooling Indoor : D.B. 7: (8 F) W.B. 9: (66 F) Outdoor : D.B. 5: (95 F) W.B. 4: (75 F) Heating Indoor : D.B. : (68 F) Outdoor : D.B. 7: (45 F) W.B. 6: (4 F) Refrigerant piping length (one way) : 5 m (6 ft.). Guaranteed operating range W: mm 8 (9) D: mm 8 (9) H: mm 98 (5) W: in -/6 (7-/8) D: in -/6 (7-/8) H: in -/4 (-/8) Unit (Panel)Weight kg 5 (6) 5 (6) 7 (6) lb 55 () 55 () () Field drain pipe O.D. mm in -/4 Outdoor Air flow CMM unit CFM,,5 Sound level at cooling db(a) 5 5 Sound level at heating db(a) External finish Ivory Munsell Y 7.8/. Dimension W: mm 9 D: mm + H: mm 94 W: in 7-/8 D: in + -/6 H: in 7-/8 5-/8 Weight kg lb 65 8 Refrigerant Gas side O.D. mm 5.88 pipe size in 5/8 Liquid side O.D. mm 9.5 in /8 Refrigerant Height difference m Maximum pipe length Length m Maximum Maximum *Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. Indoor Outdoor Cooling Upper limit D.B. 5 C, W.B..5 C D.B. 46: er limit D.B. 9 C, W.B. 5 C D.B. 5:** Heating Upper limit D.B. 8 C D.B. :, W.B. 5: er limit D.B. 7 C D.B. 5:, W.B. 5:. Guaranteed voltage V, Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase V, Hz Outdoor unit Single phase V, Hz **If optional air protect guide is installed, D.B. 5: OCS

4 Model Name Indoor unit PLA-SPBA PLA-SP5BA PLA-SPBA Outodoor unit PUHZ-SPYHA PUHZ-SP5YHA PUHZ-SPYHA Cooling Capacity BTU/h, 4, 46, kw 9.4 ( ). (5.5.). (5.5 4.) Total input kw EER..6 Energy label class B D SHF Design load kw 9.4 Annual electricity consumption* kw h/a 644 SEER 5. Energy efficiency class A Heating Capacity BTU/h 8, 47,8 54, kw. (4.5.5).5 (5. 5.) 5.5 (5. 7.) Total input kw COP.4. Energy label class B C Design load kw 8. Decrared capacity at reference design temperature 6. ( :) at bivalent temperature 7. ( 7:) at operation limit temperature 5. ( 5:) Backup heating capacity.7 Annual electricity consumption* kw h/a 945 SCOP.8 Energy efficiency class A Power supply Phase { Cycle Hz Voltage V Breaker size A 6 Indoor unit Air flow CMM (-Medium-Medium-) CFM External pressure Pa Sound level db(a) (-Medium-Medium-) External finish (Panel) White Munsell 6.4Y 8.9/.4 Unit (Panel) Dimension W: mm 8 (9) D: mm 8 (9) H: mm 98 (5) W: in -/6 (7-/8) D: in -/6 (7-/8) H: in -/4 (-/8) Unit (Panel)Weight kg 5 (6) 5 (6) 7 (6) lb 55 () 55 () () Field drain pipe O.D. mm in -/4 Outdoor Air flow CMM unit CFM,,5 Sound level at cooling db(a) 5 5 Sound level at heating db(a) External finish Ivory Munsell Y 7.8/. Dimension W: mm 9 D: mm + H: mm 94 W: in 7-/8 D: in + -/6 H: in 7-/8 5-/8 Weight kg 77 lb 69 Refrigerant Gas side O.D. mm 5.88 pipe size in 5/8 Liquid side O.D. mm 9.5 in /8 Refrigerant Height difference m Maximum pipe length Length m Maximum Maximum *Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. Notes:. Rating conditions (ISO T) Cooling Indoor : D.B. 7: (8 F) W.B. 9: (66 F) Outdoor : D.B. 5: (95 F) W.B. 4: (75 F) Heating Indoor : D.B. : (68 F) Outdoor : D.B. 7: (45 F) W.B. 6: (4 F) Refrigerant piping length (one way) : 5m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor unit V, Hz Indoor Outdoor Outdoor unit V, Hz Cooling Upper limit D.B. 5 C, W.B..5 C D.B. 46 C 4. Above data are based on the indicated voltage. er limit D.B. 9 C, W.B. 5 C D.B. 5 C** Indoor unit Single phase V, Hz Heating Upper limit D.B. 8 C D.B. C, W.B. 5 C Outdoor unit phase V, Hz er limit D.B. 7 C D.B. 5 C, W.B. 5 C **If optional air protect guide installed, D.B. 5: OCS 4

5 -. CEILING-CCEALED TYPE Model Name Indoor unit PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) Outodoor unit PUHZ-SPVHA PUHZ-SP5VHA PUHZ-SPVHA Cooling Capacity BTU/h, 4, 46, kw 9.4 ( ). (5.5.). (5.5 4.) Total input kw EER.8. Energy label class C B SHF Design load kw 9.4 Annual electricity consumption* kw h/a 7 SEER 4.6 Energy efficiency class B Heating Capacity BTU/h 8, 47,8 54, kw. (4.5.5).5 (5. 5.) 5.5 (5. 7.) Total input kw COP.6.4 Energy label class A A Design load kw 8. Decrared capacity at reference design temperature 6. ( :) at bivalent temperature 7. ( 7:) at operation limit temperature 5. ( 5:) Backup heating capacity.7 Annual electricity consumption* kw h/a 945 SCOP.8 Energy efficiency class A Power supply Phase { Cycle Hz Voltage V Breaker size A Indoor unit Outdoor unit Refrigerant pipe size Refrigerant pipe length Air flow (-Medium-Medium-) External pressure Pa 5/ / / / *Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. Notes:. Rating conditions (ISO T) Cooling Indoor : D.B. 7: (8 F) W.B. 9: (66 F) Outdoor : D.B. 5: (95 F) W.B. 4: (75 F) Heating Indoor : D.B. : (68 F) Outdoor : D.B. 7: (45 F) W.B. 6: (4 F) OCS Refrigerant piping length (one way) : 5 m (6 ft.). Guaranteed operating range CMM CFM Sound level db(a) (-Medium-Medium-) External finish (Panel) Galvanized sheets Dimension W: mm D: mm 7 H: mm W: in 55-/8 6 D: in 8-7/8 H: in 9-7/8 Weight kg 4 () 4 (4) 47 (46) lb 9 (89) 95 (9) 4 () Field drain pipe O.D. mm in -/4 Air flow CMM CFM,,5 Sound level at cooling db(a) 5 5 Sound level at heating db(a) External finish Ivory Munsell Y 7.8/. Dimension W: mm 9 D: mm (+) H: mm 94 W: in 7-/8 D: in + -/6 H: in 7-/8 5-/8 Weight kg lb 65 8 Gas side O.D. mm 5.88 in 5/8 Liquid side O.D. mm 9.5 in /8 Height difference m Maximum Length m Maximum Maximum Indoor Outdoor Cooling Upper limit D.B. 5 C, W.B..5 C D.B. 46: er limit D.B. 9 C, W.B. 5 C D.B. 5:** Heating Upper limit D.B. 8 C D.B. :, W.B. 5: er limit D.B. 7 C D.B. 5:, W.B. 5: 5. Guaranteed voltage V, Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase V, Hz Outdoor unit Single phase V, Hz **If optional air protect guide is installed, D.B. 5:

6 Model Name Indoor unit PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) Outodoor unit PUHZ-SPYHA PUHZ-SP5YHA PUHZ-SPYHA Cooling Capacity BTU/h, 4, 46, kw 9.4 ( ). (5.5.). (5.5 4.) Total input kw EER.8. Energy label class C B SHF Design load kw 9.4 Annual electricity consumption* kw h/a 7 SEER 4.6 Energy eficiency class B Heating Capacity BTU/h 8, 47,8 54, kw. (4.5.5).5 (5. 5.) 5.5 (5. 7.) Total input kw COP.6.4 Energy label class A A Design load kw 8. Decrared capacity at reference design temperature 6. ( :) at bivalent temperature 7. ( 7:) at operation limit temperature 5. ( 5:) Backup heating capacity.7 Annual electricity consumption* kw h/a 945 SCOP.8 Energy eficiency class A Power supply Phase { Cycle Hz Voltage V Breaker size A 6 Indoor unit Air flow (-Medium-Medium-) External pressure Pa 5/ / / / CMM CFM Sound level db(a) (-Medium-Medium-) External finish (Panel) Galvanized sheets Dimension W: mm D: mm 7 H: mm W: in 55-/8 6 D: in 8-7/8 H: in 9-7/8 Weight kg 4 () 4 (4) 47 (46) lb 9 (89) 95 (9) 4 () Field drain pipe O.D. mm in -/4 Outdoor Air flow CMM unit CFM,,5 Sound level at cooling db(a) 5 5 Sound level at heating db(a) External finish Ivory Munsell Y 7.8/. Dimension W: mm 9 D: mm (+) H: mm 94 W: in 7-/8 D: in + -/6 H: in 7-/8 5-/8 Weight kg 77 lb 69 Refrigerant Gas side O.D. mm 5.88 pipe size in 5/8 Liquid side O.D. mm 9.5 in /8 Refrigerant Height difference m Maximum pipe length Length m Maximum Maximum *Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. Notes:. Rating conditions (ISO T) Cooling Indoor : D.B. 7: (8 F) W.B. 9: (66 F) Outdoor : D.B. 5: (95 F) W.B. 4: (75 F) Heating Indoor : D.B. : (68 F) Outdoor : D.B. 7: (45 F) W.B. 6: (4 F) Refrigerant piping length (one way) : 5 m (6 ft.). Guaranteed operating range. Guaranteed voltage Indoor unit V, Hz Indoor Outdoor Outdoor unit V, Hz Cooling Upper limit D.B. 5 C, W.B..5 C D.B. 46 C 4. Above data are based on the indicated voltage. er limit D.B. 9 C, W.B. 5 C D.B. 5 C** Indoor unit Single phase V, Hz Heating Upper limit D.B. 8 C D.B. C, W.B. 5 C Outdoor unit phase V, Hz er limit D.B. 7 C D.B. 5 C, W.B. 5 C **If optional air protect guide installed, D.B. 5: OCS 6

7 OUTLINES AND DIMENSIS -. INDOOR UNIT PLA-SPBA PLA-SP5BA PLA-SPBA Ceiling hole ~45 8~9 ~45 8 Fresh air intake hole Suspension bolt pitch ~45 Unit : mm Detail connecting of branch duct(both aspects) 9 9 Cut out hole (7.5) 8 Air intake grille Branch duct hole 9 C D Suspension bolt M or W/8 Suspension bolt lower edge Ceiling Grille mm or more 9 * * Air outlet hole 8 6 ~ * Indoor unit mm or more Obstacle Control wire entry M Remote controller terminal block Indoor unit/outdoor unit connecting terminal block 87.5 Indoor power supply terminal block(optional parts) Drain pipe Connected the attached connected to VP-5 ( flexible pipe or socket. ) M 8 Power supply wire, Indoor unit/outdoor unit connecting wire entry 597 Air intake hole mm or more Floor Air outlet hole 9 M Indoor unit M 4 Ceiling Grille 8 6 Drain hole Drain pump clean hole and Drain emergency drainage hole 597 Air intake hole Suspension bolt pitch (7.5) * mm or more from floor For high attachment * Vane motor 9 * 7 +5 Auto vane (Air outlet) 8~9 Ceiling hole ~45 * 5 Model PLA-SPBA PLA-SP5BA PLA-SPBA A B Branch duct hole Keep approximately to 5mm space between unit ceiling and ceiling slab. Receiver {75 Burring hole pitch 58 Burring hole -[.8 DEFROST/STAND BY lamp Operation lamp Cut out hole [ Ceiling In case of standard grille : PLP-6BA / PLP-6BAMD In case of auto-grille : PLP-6BAJ In case of wireless remote controller : PLP-6BALM Emergency operation switch<cooling>and Emergency Up/Down switch<up> Emergency operation switch<heating>and Emergency Up/Down switch<down> [ Cut out hole Burring hole pitch [5 4-[.8 Burring hole Detail drawing of fresh air intake hole * Refrigerant pipe Refrigerant pipe [9.5 [5.88 Flared connection Flared connection /8 inch 5/8 inch L.L Filter Auto grille Air intake grille up/down distance A B C D E 8 Air intake grille Ceiling Note. Please choose the grille from a standard grille, auto-grille.. As for drain pipe, please use VP-5(O.D. [ PVC TUBE). Drain pump is included. Max. lifting height is 8mm from the ceiling.. As for suspension bolt, please use M or W/8. (Procured at local site) 4. Electrical box may be removed for the service purpose. Make sure to slack the electrical wire little bit for control/power wires connection. 5. The height of the indoor unit is able to be adjusted with the grille attached. 6. For the installation of the optional high efficiency filter or optional multi-functional casement. ) Requires E or more space between transom and ceiling for the installation. ) Add 5 mm to the dimensions * marked on the figure. ) The optional high efficiency filter must be used jointly with the optional multi-functional casement. 7. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. (It becomes the cause of dew drops/water dew.) 8. As for necessary installation/service space, please refer to the left figure * * Max. 4.m OCS 7

8 PEAD-SPJA PEAD-SP5JA PEAD-SPJA xe-[.9 5 Suspension bolt hole 4-4x Slot 8 Unit : mm 58 x(e-)=f 57 D (Duct) Air outlet (Suspension bolt pitch) Air inlet A B(Suspension bolt pitch) C G Air Filter Refrigerant piping Flare connection (liquid) -[.9 78 (Duct) Refrigerant piping Flare connection (gas) 7 8 Drain pipe (O.D.[) Drain pump 4 Drain pipe(o.d.[) (Spontaneous draining) Terminal block (Remote controller transmission line) 7 Control box Terminal block (Indoor/Outdoor connecting line) 75±5mm (Actual length) Less than mm Less than mm Drain hose (I.D.[) <accessory> NOTE. Use M screw for the Suspension bolt (field supply).. Keep the service space for the maintenance at the bottom.. This chart indicates for PEAD-SP 5 JA models,which have fans. 4. In case that the inlet duct is used, remove the air filter (supplied with the unit), then install the filter (field supply) at suction side. Model A B C D E F G PEAD-SP/5JA PEAD-SPJA Gas pipe Liquid pipe [ 5.88 [ 9.5 More than mm More than mm N-[.9 Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. 6 P J K Q Kx(L-)=M Qx(R-)=S J 777 Access door Model PEAD-SP/5JA PEAD-SPJA H J K L M N P Q R S H Note 4 ~ 4 More than Required space for service and maintenance OCS 8

9 PEAD-SPJA PEAD-SP5JAL PEAD-SPJAL xe-[.9 5 Suspension bolt hole 4-4x Slot 8 Unit : mm x(e-)=f 57 D (Duct) Air outlet Air inlet A B(Suspension bolt pitch) C G Air Filter (Suspension bolt pitch) Refrigerant piping Flare connection (liquid) -[.9 78 (Duct) Refrigerant piping Flare connection (gas) Drain pipe(o.d.[) 7 Terminal block (Remote controller transmission line) 75±5mm (Actual length) Control box Terminal block (Indoor/Outdoor connecting line) Drain hose (I.D.[) <accessory> NOTE. Use M screw for the Suspension bolt (field supply).. Keep the service space for the maintenance at the bottom.. This chart indicates for PEAD-SP 5 JAL models,which have fans. 4. In case of the inlet duct is used,remove the air filter (supplied with the unit), then install the filter (field supply) at suction side. Model A B C D E F G PEAD-SP/5JAL PEAD-SPJAL Gas pipe Liquid pipe [ 5.88 [ 9.5 More than mm More than mm N-[.9 Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. 6 P J K Q Kx(L-)=M Qx(R-)=S J Model PEAD-SP/5JAL PEAD-SPJAL H J K L M N P Q R S Access door H Note 4 ~ 4 More than OCS Required space for service and maintenance 9

10 -. OUTDOOR UNIT PUHZ-SPVHA PUHZ-SPYHA Unit : mm (9) Rear Air Intake 75 Installation Feet Side Air Intake o6 oval holes (Foundation Bolt M) Air Discharge -U Shaped notched holes (Foundation Bolt M) Over Less than FREE SPACE (Around the unit) The diagram below shows a basic example. Explanation of particular details is given in the installation manuals etc. SERVICE SPACE Dimensions of space needed for service access are shown in the below diagram. FOUNDATI BOLTS Please secure the unit firmly with 4 foundation (M) bolts. (Bolts and washers must be purchased locally.) 4 PIPING-WIRING DIRECTIS Piping and wiring connections can be made from 4 directions: front, right rear and below. Over <Foundation bolt height> over mm over mm Over Service space Over Example of Notes Refrigerant GAS pipe connection (FLARE){5.88(5/8 inch) Refrigerant LIQUID pipe connection (FLARE){ 9.5(/8 inch) w Indication of STOP VALVE connection location. Side Air Intake Handle for moving Piping Knockout Hole Details Front piping cover Rear piping cover Rear Air Intake Handle for moving Handle for moving Air Intake 9 Handle for moving Earth terminal Terminal Connections Left Power supply wiring Right Indoor/Outdoor wiring Service panel Handle for moving Bottom piping hole (Knockout) Drain hole (5-{) w 4 w 447 SPVHA:6 SPYHA:589 FOUNDATI over mm over mm Front trunking hole (Knockout) Power supply wiring hole (-{7Knockout) 45 Right piping hole (Knockout) 75 Power supply wiring hole (-{7Knockout) Right trunking hole (Knockout) 45 Power supply wiring hole (-{7Knockout) Rear trunking hole (Knockout) {9 { {9 Front piping hole (Knockout) Rear piping hole (Knockout) FREE OCS

11 Ov m m m m 5 Over Service space Example of Notes er Ov er Ov Over Front piping hole (Knockout) 9 {9 65 Power supply wiring hole (-{7Knockout) Front trunking hole 45 (Knockout) Right piping hole (Knockout) Piping Knockout Hole Details 55 {9 Air intake Handle for moving w Indication of STOP VALVE connection location. Refrigerant GAS pipe connection (FLARE){5.88(5/8 inch) Refrigerant LIQUID pipe connection (FLARE){ 9.5(/8 inch) m m m m er er 55 7 Ov Right trunking hole (Knockout) 9 {9 FOUNDATI Handle for moving Handle for moving Rear piping hole (Knockout) Rear trunking hole (Knockout) Side Air Intake Rear Air Intake Piping and wiring connections can be made from 4 directions: front, right, rear and below. 4 PIPING-WIRING DIRECTIS Power supply wiring hole (-{7Knockout) <Foundation bolt height> Please secure the unit firmly with 4 foundation (M) bolts. (Bolts and washers must be purchased locally.) FOUNDATI BOLTS Power supply wiring hole (-{7Knockout) Dimensions of space needed for service access are shown in the below diagram. Over Over The diagram below shows a basic example. Explanation of particular details is given in the installation manuals etc. FREE SERVICE SPACE Handle for moving Side Air Intake FREE SPACE (Around the unit) Less than Earth terminal 9 Air Discharge Installation Feet Rear Air Intake 4 Drain hole (5-{) 7 Handle for moving Service panel Terminal connection Left Power supply wiring Right Indoor/Outdoor wiring - x 6 Oval holes (Foundation Bolt M) U Shaped notched holes (Foundation Bolt M) (9) Front piping cover Rear piping cover Bottom piping hole (Knockout) w 447 w 4 OCS SP5/VHA: 76 SP5/YHA: 994 PUHZ-SP5VHA PUHZ-SP5YHA PUHZ-SPVHA PUHZ-SPYHA Unit : mm

12 -. WIRED REMOTE CTROLLER PAR-MAA/MAA 9 PAC-YT5CRA 4.5 OCS

13 -4. WIRELESS REMOTE CTROLLER OCS

14 4 WIRING DIAGRAM 4-. INDOOR UNIT PLA-SPBA PLA-SP5BA PLA-SPBA [LEGEND] SYMBOL NAME I.B INDOOR CTROLLER BOARD CNL CNECTOR (LOSSNAY) CN CNECTOR (REMOTE SWITCH) CN4 CNECTOR (HA TERMINAL-A) CN5 CNECTOR (CENTRALLY CTROL) FUSE FUSE (T6.ALV) LED POWER SUPPLY (I.B) LED POWER SUPPLY (R.B) LED TRANSMISSI (INDOOR-OUTDOOR) SW SWITCH (MODEL SELECTI) See table SW SWITCH (CAPACITY CODE) See table SWE CNECTOR (EMERGENCY OPERATI) X RELAY (DRAIN PUMP) DCL REACTOR DP DRAIN PUMP FS DRAIN FLOAT SWITCH SYMBOL MF MV TB TB4 TB5,TB6 NAME FAN MOTOR VANE MOTOR TERMINAL BLOCK (Indoor unit Power (option)) TERMINAL BLOCK (INDOOR/OUTDOOR CNECTING LINE) TERMINAL BLOCK (REMOTE CTROLLER TRANSMISSI LINE) TH ROOM TEMP. THERMISTOR ( C / 5kΩ, 5 C / 5. 4kΩ DETECT) TH PIPE TEMP. THERMISTOR/LIQUID ( C / 5kΩ, 5 C / 5. 4kΩ DETECT) TH5 CD. / EVA. TEMP. THERMISTOR ( C / 5kΩ, 5 C / 5. 4kΩ DETECT) OPTI PART W.B PCB FOR WIRELESS REMOTE CTROLLER BZ BUZZER LED LED (OPERATI INDICATI : GREEN) LED LED (PREPARATI FOR HEATING : ORANGE) RU RECEIVING UNIT SW SW EMERGENCY OPERATI (HEAT / DOWN) EMERGENCY OPERATI (COOL / UP) <Table > SW (MODEL SELECTI) SW MODELS Manufacture/Service PLA-SP 4 5 /5BA 4 5 PLA-SPBA <Table > SW (CAPACITY CODE) SW MODELS Manufacture/Service 4 5 PLA-SPBA 4 5 PLA-SP5BA PLA-SPBA 4 5 The black square ( ) indicates a switch position. I.B VANE CNV AUTO GRILLE CNG () WIRELESS CN9 4 9 SW Refer to tables and SW LED LED LED I-SEE SENSOR CN4Y 4 TB6 R.B J4 J4 Pair No. CNL I-SEE SENSOR MOTOR CN6Y (RED) 6 TRANSMISSI WIRES DCV CN CN5 5 CN4 4 SWE CN5 5 TB5 FLOAT SW CN4F OUTDOOR CN () 5 INDOOR/OUTDOOR COMMUNICATI CNC (BLU) DC5V REMOC CN (BLU) RECTIFICATI LIQUID/PIPE CN44 INTAKE CN (RED) FAN D.U.M CNMF CNP (BLU) YLW FUSE DCL AUTO GRILLE X POWER CNAC YLW ORN ORN BRN TB4 YLW S ORN S S TO OUTDOOR UNIT M M M M MV MV MV MV GRILLE CNB SW SW RU BZ LED LED W.B I-SEE SENSOR M MT I-SEE SENSOR CORNER PANEL (OPTI PART) FS U.B 5 CNG CNA AUTOMATIC FILTER ELEVATI PANEL (OPTI PART) t t t TH TH5 TH MS ~ MF M ~ DP Be sure to turn off the source power and then disconnect fan motor connector. (Failure to do so will cause trouble in fan motor) Notes:. SymboIs used in wiring diagram above are, :Connector, : Terminal (block).. Indoor and outdoor connecting wires are made with poiarities, make wiring matching terminal numbers (S, S, S).. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of V), adopting superimposed system of power and signal. When work to Supply power separately to indoor and outdoor units was applied, refer to Fig *. For power supply system of this unit, refer to the caution label located near this diagram. *Fig. CN () 5 CNC (BLU) I.B YLW ORN RED BLU GRN/YLW TB L N YLW TB4 ORN S ORN S BRN S INDOOR/OUTDOOR COMMUNICATI POWER SUPPLY ~(PHASE) V Hz TO OUTDOOR UNIT Please set the voltage using the remote controller. For the setting method,please refer to the indoor unit Installation Manual. OCS 4

15 PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) INSIDE SECTI OF CTROL BOX TB5 TO MA REMOTE CTROLLER CN9 LED CNC (Blue) CN SW SW SW5 CN4F SW6 SWE (Red) CN 4 CN4 CN4F A CN (Red) CNL CN5 t TH LED CNXB CNXC CN5 (Red) CNA (Black) CN (Blue) LED I.B. (Blue) CNXA 4 (Blue) CNP U CNXB 4 5 ZNR X DSA 5 ZNR U CNXC F (Blue) CNXA CND (Red) X 4 P.B. DC8-V Rectifier circuit CNMF ACL TB4 S S S A TO OUTDOOR UNIT <Table > SW (MODEL SELECTI) MODELS PEAD-SP JA(L) <Table > SW (CAPACITY CODE) SW CAPACITY SETTING SW 4 5 SW5 4 5 The black square ( ) indicates a switch position SW6 t t TH TH5 FS FOR PEAD-RP JA REFER TO "A" FOR PEAD-RP JAL I.B. Indoor controller board I.B. Connector (-V Analog input) Connector (Lossnay) Connector (Remote switch) Connector (HA terminal-a) Connector (Centrally control) P.B. CNA CNL CN CN4 CN5 CN9 CN5 LED LED LED Connector (Wireless) Connector (IT terminal) LED(Power supply) LED(Remote controller supply) LED(Transmission indoor-outdoor) SW SW SW5 SW6 SWE F ZNR, DSA X X Indoor controller board Switch (for model selection) Switch (for capacity code) Switch (for model selection) Switch (for model selection) Connector (emergency operation) Power supply board Fuse ACV 6.A Varistor Arrester Aux. relay Aux. relay M ~ Drainpump TH TH TH5 ACL FS TB4 TB5 LY FOR PEAD-RP JAL SYMBOL NAME SYMBOL NAME SYMBOL NAME SYMBOL EXPLANATI MS ~ Fan motor Intake air temp. Thermistor Pipe temp. Thermistor/liquid Cond./eva.temp. Thermistor AC reactor (Power factor improvement) Float switch Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) NOTE:. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing.. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S,S,S).. Symbols used in wiring diagram above are, terminal block, connector. TO CND < A> (IN CASE OF CNECT ACL THE REPLACEMENT WIRING) TO CNC L N S S S POWER SUPPLY ~ (PHASE) -V Hz TO OUTDOOR UNIT OCS 5

16 4-. OUTDOOR UNIT PUHZ-SPVHA PUHZ-SP5VHA PUHZ-SPVHA SYMBOL NAME SYMBOL NAME SYMBOL NAME TB MC MF, MF S4 6H Terminal Block <Power Supply, Indoor/Outdoor> Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) Pressure Switch P.B. U/V/W LI NI DCL, DCL Power Circuit Board Connection Terminal <U/V/W-Phase> Connection Terminal <L-Phase> Connection Terminal <N-Phase> Connection Terminal <Reactor> SW9 SWP CN SS CNDM Switch <Function Switch> Switch <Pump Down> TH TH6 TH7 Thermistor <Liquid> Thermistor <-Phase Pipe> Thermistor <Ambient> IGBT EI, E, E, E4 C.B. Power Module Connection Terminal <Ground> Controller Circuit Board CNM LED, LED F, F, F, F4 Fuse <T6.ALV> TH8 Thermistor (internal) <Heat Sink> SW X5, X5, X54, X55 Relay TH LEV-A DCL CB CY, CY SV CH Thermistor <Comp. Surface> Linear Expansion Valve Reactor Main Smoothing Capacitor Capacitor Solenoid Valve (Bypass Valve) Crankcase Heater SW4 SW5 SW6 SW7 SW8 Switch <Manual Defrost, Defect History, Record Reset, Refrigerant Address> Switch <Test Operation> Switch <Function Switch, Model Select> Switch <Model Select> Switch <Function Switch> Switch <Function Switch> Connector <Emergency Operation> Connector <Connection for Option> Connector <Connection for Option> Connector <Connection for Option> LED <Operation Inspection Indicators> When M-NET adapter is connected MS ~ MF MS ~ MF * C. B. CNF 7 CNF 7 CNDC (PNK) F CNS F TH TH7 TH6 TH TRANS CNAC t TH () 4 t t t 4 TH7/6 (RED) TH 7 CN F F4 7 6H 6H (YLW) X5 LED LED CN4 LEV-A M LEV-A X55 6 X CNVMNT CNMNT CN5C (RED) CNM X5 S4 SV SV SS (GRN) (BLU) /CH (GRY) 4 SW5 SW8 SW4 SWP * SW6 SW * CN SW7 SW9 CNDM CN5 5 5 A B 5 CN5 M-NET ADAPTER CNM S TB7 M-NET CND S4 SV CH * * 7 P. B. CN4 CN 7 CN5C (RED) 5C CB WHT RED t TH8 N P CNDC (PNK) IGBT E4 5C E E CNAC (RED) CNAC BRN ORN RED WHT W V U DCL DCL EI NI LI WHT RED W V U MS ~ MC DCL WHT RED BLU GRN/YLW YLW ORN BRN L N S S S CY CY TB * MODEL SELECT The black square ( ) indicates a switch position. MODEL SW6 SW5-6 * V 5V POWER SUPPLY ~/N V Hz INDOOR UNIT V * SW5 - to 5 : Function Switch * SP5/ only OCS 6

17 PUHZ-SPYHA SYMBOL NAME SYMBOL NAME SYMBOL NAME TB Terminal Block <Power Supply> RS Rush Current Protect Resistor SW4 Switch <Test Operation> TB Terminal Block <Indoor/Outdoor> CY, CY Capacitor SW5 Switch <Function Switch, Model Select> MC Motor for Compressor P.B. Power Circuit Board SW6 Switch <Model Select> MF Fan Motor TB-U/V/W Connection Terminal <U/V/W-Phase> SW7 Switch <Function Switch> S4 Solenoid Valve (Four-Way Valve) TB-L/L/L Connection Terminal <L/L/L-Power Supply> SW8 Switch <Function Switch> 6H Pressure Switch TB-P/P Connection Terminal SW9 Switch <Function Switch> TH Thermistor <Liquid> X5CA/B 5C Relay SWP Switch <Pump Down> TH6 Thermistor <-Phase Pipe> N.F. Noise Filter Circuit Board CN Connector <Emergency Operation> TH7 Thermistor <Ambient> LI/LI/LI/NI Connection Terminal <L/L/L/N-Power Supply> SS Connector <Connection for Option> TH8 Thermistor <Heat Sink> LO/LO/LO Connection Terminal <L/L/L-Power Supply> CNDM Connector <Connection for Option> TH Thermistor <Comp. Surface> GD, GD Connection Terminal <Ground> CNM Connector <Connection for Option> LEV-A Linear Expansion Valve C.B. Controller Circuit Board LED, LED LED <Operation Inspection Indicators> DCL Reactor SW Switch <Manual Defrost, Defect History, F, F, F, F4 Fuse <T6.ALV> ACL4 Reactor Record Reset, Refrigerant Address> X5, X5, X54, X55 Relay MF MS ~ CNS TH TH7 TH6 TH C.B. t t t t CNF 4 7 TH TH7/6 TH () (RED) CNDC (PNK) F F TRANS CNAC 4 CN F F4 6H 6H (YLW) 7 7 LED LEV-A M 6 LEV-A LED X5 S4 (GRN) 5 CNVMNT CNMNT CNM 4 X55 CN4 SV (BLU) 5 X54 SV /CH (GRY) SW5 SW8 SW4 SWP * SW6 SW X5 * SS CN5 CNDM SW9 SW7 CN 5 When M-NET adapter is connected 5 5 CN5 A B S TB7 M-NET ADAPTER CNM M-NET CND S4 TH8 P.B. t 7 7 CN6 CN5 CN CN4 (RED) LOUT TB-L X5CB CY CY LIN TB-L WHT X5CA + RED RED RS RED TB-L INDOOR UNIT TB S S S YLW ORN BRN TB-U TB-V TB-W RED WHT V W U MS ~ TB-P TB-P DCL MC TB RED L LI CNAC CNCT (RED) CNAC (RED) LO RED POWER SUPPLY N~ V Hz L L N WHT BLU LI LI NI LO LO WHT GRN/YLW N.F. GD GD CNDC (PNK) + WHT WHT + - CNL (BLU) ACL4 * MODEL SELECT The black square ( ) indicates a switch position. MODEL Y SW * SW5 - to 5 : Function Switch SW5-6 * M-NET ADAPTER SYMBOL NAME TB7 Terminal Block <M-NET connection> CN5 Connector <Transmission> CND Connector <Power Supply> CNM Connector <M-NET communication> OCS 7

18 PUHZ-SP5YHA PUHZ-SPYHA SYMBOL NAME SYMBOL NAME SYMBOL NAME TB Terminal Block<Power Supply > CY,CY Capacitor SW5 Switch<Function Switch, Model Select> TB Terminal Block<Indoor/Outdoor > P.B. Power Circuit Board SW6 Switch<Model Select> MC Motor for Compressor TB-U/V/W Connection Terminal<U/V/W-Phase> SW7 Switch<Function Switch> MF, MF Fan Motor TB-L/L/L Connection Terminal<L/L/L-Power Supply> SW8 Switch<Function Switch> S4 Solenoid Valve (Four-Way Valve) TB-P Connection Terminal SW9 Switch<Function Switch> SV Solenoid Valve (Bypass Valve) TB-P Connection Terminal SWP Switch<Pump Down> CH Crankcase Heater TB-C Connection Terminal CN Connector<Emergency Operation> 6H Pressure Switch TB-N Connection Terminal SS Connector<Connection for Option> TH Thermistor<Liquid> X5A 5C Relay CNDM Connector<Connection for Option> TH6 Thermistor<-Phase Pipe> N.F. Noise Filter Circuit Board CNM Connector<Connection for Option> TH7 Thermistor<Ambient> LI/LI/LI/NI Connection Terminal<L/L/L/N-Power Supply> LED,LED LED<Operatiion Inspection Indicators> TH8 Thermistor (internal) <Heat Sink> LO/LO/LO Connection Terminal<L/L/L/N-Power Supply> F,F,F,F4 FUSE<T6.ALV> TH Thermistor<Comp. Surface> GD, GD Connection Terminal<Ground> X5,X5,X54,X55 Relay LEV-A ACL4 Electronic Expansion Valve Reactor C.B. SW Controller Circuit Board Switch<Manual Defrost, Defect History, Record DCL Reactor Reset, Refrigerant Address> CB, CB Main Smoothing Capacitor SW4 Switch<Test Operation> RS Rush Current Protect Resistor 6H TH TH7 TH6 TH LEV-A When M-NET adapter is connected M 5 5 MS C.B. t t t t ~ 5 CNF * * MF TH TH7/6 TH LEV-A CNVMNT CNMNT () (RED) MS ~ MF CNS CNF 7 CNDC (PNK) F F TRANS CNAC 4 CN F F4 6H (YLW) 7 7 LED LED X5 S4 (GRN) CNM 4 X55 CN4 SV (BLU) X54 SW5 SW8 SW4 SWP SW6 SW X5 CN5 CNDM SW9 SW7 CN SV /CH SS (GRY) 5 A B S CN5 TB7 M-NET ADAPTER CNM M-NET CND S4 SV CH P.B. 7 INDOOR UNIT CY TB S S S CY BRN ORN YLW RS RED CN4 CN5 (RED) X5A TB-P DCL CN RED TB-P TH8 t CB WHT TB-C + CB TB-V TB-N TB-W TB-U TB-L TB-L TB-L WHT RED WHT RED W MC V MS U ~ TB RED L LI CNAC CNCT (RED) CNAC (RED) LO RED POWER SUPPLY N~ V Hz L L N WHT BLU LI LI NI LO LO WHT GRN/YLW N.F. GD GD CNDC (PNK) + WHT WHT + -- CNL (BLU) ACL4 * MODEL SELECT is the switch position MODEL SW6 5Y Y SW5-6 * * SW5 - to 5 : Function Switch M-NET ADAPTER SYMBOL NAME TB7 Terminal Block <M-NET connection> CN5 Connector <Transmission> CND Connector <Power Supply> CNM Connector <M-NET communication> OCS 8

19 5 REFRIGERANT SYSTEM DIAGRAM 5-. INDOOR UNIT PLA-SP BA PEAD-SP JA(L) Heat exchanger Thermistor TH5 (Cond./Eva. temperature) Strainer(#) Refrigerant GAS pipe connection (Flare) Refrigerant flow in cooling Refrigerant flow in heating Distributor Thermistor TH with strainer(#) Pipe temperature (Liquid) Thermistor TH (Room temperature) Strainer(#) Refrigerant LIQUID pipe connection (Flare) OCS 9

20 5-. OUTDOOR UNIT Unit : mm PUHZ-SPVHA PUHZ-SPYHA Refrigerant flow in cooling Refrigerant flow in heating Refrigerant GAS pipe 5.88mm([5/8) Stop valve (#) Strainer 4-way valve Service port (check) pressure protect switch Outdoor heat exchanger Thermistor (TH6) Service port (check) Accumulator Muffler Thermistor (TH) Thermistor (TH) Distributor Refrigerant LIQUID pipe 9.5mm([/8) Strainer (#) Stop valve (with service port) Compressor (#) Strainer (#) Strainer Linear expansion valve PUHZ-SP5VHA PUHZ-SP5YHA PUHZ-SPVHA PUHZ-SPYHA Refrigerant GAS pipe 5.88mm([5/8) Stop valve (#) Strainer Service port (check) 4-way valve Bypass valve Service port (check) pressure protect switch Thermistor (TH6) Muffler Thermistor (TH) Distributor Thermistor (TH) Capillary tube ([4.o[.o-L)o Refrigerant LIQUID pipe 9.5mm([/8) Strainer (#) Stop valve (with service port) Accumulator Compressor Strainer (#) Strainer (#) Linear expansion valve OCS

21 6 PERFORMANCE CURVES FOR THE COMBINATI OF OUTDOOR UNIT PUHZ-SP/5/VHA PUHZ-SP/5/YHA Cooling capacity.4 Indoor intake air wet-bulb temperature <W.B. :> Cooling capacity ratio Outdoor intake air dry-bulb temperature <D.B. :> Cooling input. 8 6 Cooling input ratio..8.6 Indoor intake air wet-bulb temperature <W.B. :> Outdoor intake air dry-bulb temperature <D.B. :> Note : These diagrams show the case where the operation frequency of a compressor is fixed. OCS

22 Heating capacity Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Heating input Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Note : These diagrams show the case where the operation frequency of a compressor is fixed. OCS

23 7 CORRECTI FACTORS PUHZ-SP/5/VHA PUHZ-SP/5/YHA Cooling capacity correction factors Refrigerant piping length (one way) Outdoor unit 5 m m m m PUHZ-SPYHA m PUHZ-SP5YHA PUHZ-SPYHA Heating capacity correction factors Refrigerant piping length (one way) Outdoor unit 5 m m m m PUHZ-SPYHA m PUHZ-SP5YHA PUHZ-SPYHA OCS

24 8 APPLICABLE EXTENSI PIPE FOR EACH MODEL 8-. PIPE LENGTH : SYSTEM <Table > Maximum pipe length Liquid pipe (mm) Gas pipe (mm) SP OD Thickness OD Thickness SP5, SP ø.7 t.8 ø9.5 t.8 ø5.88 t. Standard size m [ m] Standard size m [ m] ø9.5 t. m [ m] m [ m] ø5.88 t. 5 m [ m] m [ m] ø.7 t.8 ø9.5 t. 5 m [ m] m [ m] <Marks in the table> m [ m] : It can be used. : Cooling capacity is lowered. : Additional refrigerant charge is required when the pipe length exceeds m(sp ). The maximum pipe length Charge-less pipe length 8-. ADJUSTING THE AMOUNT OF REFRIGERANT Check additional refrigerant charging amount referring to table 5, 6 when liquid pipe is one size larger than standard diameter. <Table > Required additional charge when the liquid pipe is one size larger than the standard diameter (: SYSTEM) Liquid pipe dia. Chargeless Max. pipe length Refrigerant amount to be added SP SP5/ [.7 [.7 m m 5 m m g per m longer than m g per m longer than m If the calculation produces a negative number ( W [ ), additional charging is not necessary. <Table > Additional refrigerant charging amount for pipe of standard diameter Outdoor unit Max. pipe length Amount of unit filling refrigerant (kg) Additional refrigerant charging amount for pipe length exceeding m (kg) m m PUHZ-SPYHA m. kg.6 kg PUHZ-SP5YHA m 4.5 kg.6kg PUHZ-SPYHA m 4.5 kg.6kg 8-. CAPACITY CURVE PUHZ-SP/5/VHA, PUHZ-SP/5/YHA <Standard size> P- Capacity ratio [%] Cooling Heating P P5 P Corrected pipe length [m] OCS 4

25 9 AIR FLOW DATA 9-. OUTLET AIR SPEED AND COVERAGE RANGE PLA-SPBA PLA-SP5BA PLA-SPBA Airflow m /min. Air speed m/sec Coverage range m Note: The air coverage range is the distance to which the.5 m/sec air can reach, when air blows out horizontally from the unit at the notch position. The coverage range should be used only as a general guideline since it varies according to the size of the room and the furniture inside the room. 9-. PLA-SP BA 9-- FRESH AIR INTAKE AND BRANCH DUCT. Branch duct hole and fresh air intake hole (Fig. ) At the time of i nstallation, use the duct holes ( cut out) located at the positions shown in Fig., as and when required. A fresh air intake hole for the optional multi function casement can also be made. Note: The figure marked with * in the drawing represent the dimensions of the main unit excluding those of the optional multi function casement. When installing the optional multi function casement, add 5 mm to the dimensions marked on the figure. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. Unit : mm Fresh air intake hole A Branch duct hole Fresh air intake hole diagram -[.8 burring hole [5 burring hole pitch A Indoor unit A *58 [ cut out hole Drain pipe Ceiling Refrigerant pipe Branch duct hole diagram (view from either side) 9 9 *55 *67 [75 burring hole pitch Fig. 4-[.8 burring hole [ cut out hole OCS 5

26 . Fresh air intake volume & static pressure characteristics PLA-SP/5/BA At using multi-function casement, standard filter Static pressure[pa] - - inlet inlet Airflow rate [m /min] Direct intake to unit At using multi-function casement, high efficiency filter Static pressure[pa] Static pressure[pa] inlet Airflow rate [m /min] - - inlet Airflow rate [m /min] OCS 6

27 4. Change of outlet numbers [The optional air outlet is necessary.] To change the air outlet number to -, or -way outlet, the outlet number should be closed with the operational air outlet shutter. Indoor unit (When the air outlets are closed, close the vane by removing the vane connector.) Button Vane motor Up/down vanes Outlet concave portion Connector Vane motor Air outlet shutter plate (Option) Connector Button 5. Branch duct and change of outlet numbers <4- way air flow and branch duct> Branch duct should be connected to one of the branch duct holes on the main unit. Branch duct Air intake Air outlet <- way air flow and branch duct> Close the outlet on the side of branch duct and air flows in directions. Branch duct Air outlet closed position Air intake Air outlet <- way air flow and branch duct> Close the outlet on the side of branch duct and one of the other outlets. Air flows in directions. Branch duct Air Air outlet closed position Air intake Air outlet closed position OCS 7

28 9-. PLA-SP5BA 4-way airflow (horizontal vane) Round duct 4-way airflow (horizontal vane) Rectangular duct Duct Duct Static pressure [Pa] Static pressure [Pa] Airflow rate [m /min] 8 -way airflow (horizontal vane) Round duct Airflow rate [m /min] -way airflow (horizontal vane) Rectangular duct 8 Duct Duct Close Close Static pressure [Pa] Static pressure [Pa] Airflow rate [m /min] -way airflow (horizontal vane) Round duct Airflow rate [m /min] -way airflow (horizontal vane) Rectangular duct Duct Close 8 Duct Close Close Close Static pressure [Pa] Static pressure [Pa] Airflow rate [m /min] Airflow rate [m /min] Use of the duct holes on the indoor unit. Airflow rate of PLA-SPBA, PLA-SPBA can be calculated from the airflow rate based on the characteristic of the duct for PLA-SP5BA. Use the optional air outlet shutter plate (PAC-SH5SP-E) for -way and -way airflow. OCS 8

29 9-4. PEAD-SP JA(L) Fan performance External static pressure (Pa) PEAD-SPJA(L) (External static pressure 5Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz External static pressure (Pa) PEAD-SPJA(L) (External static pressure Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz External static pressure (Pa) Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz Limit Rated point External static pressure (Pa) Limit Rated point Airflow rate(m /min) External static pressure (Pa) 9 8 Limit Rated point Airflow rate(m /min) OCS 9

30 External static pressure (Pa) External static pressure (Pa) External static pressure (Pa) PEAD-SP5JA(L) (External static pressure 5Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SP5JA(L) (External static pressure Pa) V, Hz 9 8 Limit Rated point Airflow rate(m /min) PEAD-SP5JA(L) (External static pressure Pa) V, Hz Limit 9 8 Rated point Airflow rate(m /min) External static pressure (Pa) PEAD-SP5JA(L) (External static pressure Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SP5JA(L) (External static pressure Pa) V, Hz External static pressure (Pa) Limit Rated point Airflow rate(m /min) OCS

31 External static pressure (Pa) PEAD-SPJA(L) (External static pressure 5Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz External static pressure (Pa) PEAD-SPJA(L) (External static pressure Pa) V, Hz Limit Rated point Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz External static pressure (Pa) External static pressure (Pa) 9 8 Limit Rated point Airflow rate(m /min) PEAD-SPJA(L) (External static pressure Pa) V, Hz Limit 9 8 Rated point Airflow rate(m /min) External static pressure (Pa) Limit Rated point Airflow rate(m /min) OCS

32 NOISE CRITERI CURVES -. INDOOR UNIT PLA-SPBA NOTCH SPL(dB) LINE Medium 7 Medium 4 PLA-SP5BA NOTCH SPL(dB) LINE 4 Medium 9 Medium OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE NC- NC- NC- NC- NC- NC- PLA-SPBA NOTCH SPL(dB) LINE 44 Medium 4 Medium OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE NC- NC- NC- NC- NC- NC- CEILING.5m MICROPHE UNIT OCS

33 PEAD-SP JA(L) Ceiling concealed m Aux.duct m.5m Measurement location Noise level at anechoic room (--) Unit: db(a) Model Exrernal static pressure 5Pa Pa Pa Pa Pa PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) OCS

34 PEAD-SPJA(L) External static pressure 5Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC OCS 4

35 PEAD-SP5JA(L) External static pressure 5Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC OCS 5

36 PEAD-SPJA(L) External static pressure 5Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC- OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC External static pressure Pa 8 OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) Approximate minimum audible limit on continuous noise NC- NC- NC- NC- NC- NC OCS 6

37 -. OUTDOOR UNIT PUHZ-SPVHA PUHZ-SPYHA OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 9 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE MODE SPL(dB) COOLING HEATING LINE NC- NC- NC- NC- NC- NC- PUHZ-SP5VHA PUHZ-SP5YHA OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 9 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE MODE SPL(dB) COOLING 5 HEATING 55 LINE NC- NC- NC- NC- NC- NC- PUHZ-SPVHA PUHZ-SPYHA OCTAVE BAND SOUND PRESSURE LEVEL, db ( db =. µbar) 9 8 APPROXIMATE THRESHOLD OF HEARING FOR CTINUOUS NOISE MODE SPL(dB) COOLING 5 HEATING 56 LINE NC- NC- NC- NC- NC- NC- MICROPHE m.5m UNIT GROUND OCS 7

38 OPTIAL PARTS -. INDOOR UNIT Parts Name Model Name Applicable model Remote sensor PAC-SE4TS-E All models Remote operation adapter PAC-SFRM-E All models and wireless remote controller use model Multiple remote controller adapter PAC-SA88HA-E (pc.) PAC-75AD (pcs.) All models Remote on/off adapter PAC-SE55RA-E L/N/Earth PAC-SH5HR-E PLA-SP BA L/N PAC-SG97HR-E PEAD-SP JA(L) Decoration panel PLP-6BA Decoration panel with Wireless remote controller PLP-6BALM Decoration panel with Wired remote controller PLP-6BAMD Automatic filter elevation panel PLP-6BAJ i-see sensor corner panel PAC-SAME-E Wireless signal receiver PAR-SA9FA-E PLA-SP BA Space panel PAC-SH48AS-E Air outlet shutter plate PAC-SH5SP-E Multi-function casement PAC-SH5TM-E Flange for fresh air intake PAC-SH65OF-E -efficiency filter element PAC-SH59KF-E (PAC-SH5TM-E is needed.) Filter box PAC-KE94TB-E PEAD-SP, 5JA(L) PAC-KE95TB-E PEAD-SPJA(L) -. OUTDOOR UNIT Parts Name Model Name Applicable model M-NET adapter PAC-SF8MA-E PUHZ-SP A-control service tool PAC-SK5ST PUHZ-SP Drain socket PAC-SG6DS-E PUHZ-SP Air outlet guide (SP5 need pieces.) PAC-SG59SG-E PUHZ-SP Air protect guide (SP5 need pieces.) PAC-SG57AG-E PUHZ-SP Drain pan PAC-SG64DP-E PUHZ-SP Filter dryer ([9.5) PAC-SG8DR-E PUHZ-SP Joint pipe (Unit Extension pipe) ([5.88 [9.5) PAC-SG75RJ-E PUHZ-SP HEAD ICE : TOKYO BLDG., -7-, MARUNOUCHI, CHIYODA-KU, TOKYO -8, JAPAN CCopyright 4 MITSUBISHI ELECTRIC CORPORATI Distributed in Sep. 4 No.OCS Made in Japan New publication, effective Sep. 4 Specifications are subject to change without notice. 8

SERVICE MANUAL R410A PUHZ-SP100VHA.UK PUHZ-SP125VHA.UK PUHZ-SP125VHA PUHZ-SP140VHA.UK PUHZ-SP140VHA PUHZ-SP100YHA.UK PUHZ-SP100YHA PUHZ-SP125YHA.

SERVICE MANUAL R410A PUHZ-SP100VHA.UK PUHZ-SP125VHA.UK PUHZ-SP125VHA PUHZ-SP140VHA.UK PUHZ-SP140VHA PUHZ-SP100YHA.UK PUHZ-SP100YHA PUHZ-SP125YHA. SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL R40A January 05 No. OCH566 REVISED EDITI-A Outdoor unit [Model Name] PUHZ-SP00VHA PUHZ-SP5VHA PUHZ-SP40VHA PUHZ-SP00YHA PUHZ-SP5YHA PUHZ-SP40YHA [Service

More information

SERVICE MANUAL R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December No.OCH415 REVISED EDITION-F

SERVICE MANUAL R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December No.OCH415 REVISED EDITION-F SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL Outdoor unit [Model names] PUHZ-P00VHA PUHZ-P5VHA PUHZ-P40VHA PUHZ-P00VHA3 PUHZ-P5VHA3 PUHZ-P40VHA3 PUHZ-P00VHA4 PUHZ-P00YHA PUHZ-P00YHA PUHZ-P5YHA PUHZ-P40YHA

More information

SERVICE MANUAL R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. May No.OCH425 REVISED EDITION-F. Outdoor unit [Model names]

SERVICE MANUAL R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. May No.OCH425 REVISED EDITION-F. Outdoor unit [Model names] SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL Outdoor unit [Model names] PUHZ-HRP7VHA PUHZ-HRP00VHA PUHZ-HRP00YHA PUHZ-HRP5YHA PUHZ-HRP7VHA PUHZ-HRP00VHA PUHZ-HRP00YHA PUHZ-HRP5YHA PUHZ-HRP7VHA PUHZ-HRP00VHA

More information

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA

AA PLA-RP AA2 PEAD-RP EA PEAD-RP EA2 PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP HA PSA-RP GA SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL DATA BOOK [Model names] [Model names] PLA-RP AA PLA-RP AA PEAD-RP EA PEAD-RP EA PEAD-RP GA PKA-RP GAL PKA-RP FAL PCA-RP GA PCA-RP

More information

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK T AVAILABLE C AMPM AMPM SPLIT-TYPE, HEAT PUM PAIR CDITIERS No. OC REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PLH Indoor unit [Model names] PLH-3AK PLH-3AKH PLH-AKS PLH-AKHS PLH-5AKS PLH-5AKHS PLH-6AKS

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. OC0 TECHNICAL & SERVICE MANUAL Series SLZ Ceiling Cassettes R0A Indoor unit [Model names] SLZ-A09AR SLZ-AAR SLZ-A8AR [Service Ref.] SLZ-A09AR.TH SLZ-AAR.TH

More information

SERVICE MANUAL. R410A Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December 2013

SERVICE MANUAL. R410A Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December 2013 SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL R40A Outdoor unit [Model Name] PUHZ-SHW80VHA PUHZ-SHWVHA PUHZ-SHWYHA PUHZ-SHW40YHA Salt proof model PUHZ-SHW80VHA-BS PUHZ-SHWVHA-BS PUHZ-SHWYHA-BS PUHZ-SHW40YHA-BS

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

SERVICE MANUAL PUHZ-RP35VHA PUHZ-RP50VHA PUHZ-RP60VHA PUHZ-RP71VHA PUHZ-RP100VHA PUHZ-RP125VHA PUHZ-RP140VHA PUHZ-RP100YHA PUHZ-RP125YHA PUHZ-RP140YHA

SERVICE MANUAL PUHZ-RP35VHA PUHZ-RP50VHA PUHZ-RP60VHA PUHZ-RP71VHA PUHZ-RP100VHA PUHZ-RP125VHA PUHZ-RP140VHA PUHZ-RP100YHA PUHZ-RP125YHA PUHZ-RP140YHA SPLIT-TYPE, HEAT PUMP AIR CDITIERS June 005 No.OC334 SERVICE MANUAL R40A Outdoor unit [model names] PUHZ-RP35VHA PUHZ-RP50VHA PUHZ-RP60VHA PUHZ-RP7VHA PUHZ-RP00VHA PUHZ-RP5VHA PUHZ-RP40VHA PUHZ-RP00YHA

More information

R410A PUHZ-SW75VHA-BS.UK PUHZ-SW75VHAR3-BS.UK PUHZ-SW75VHAR4-BS.UK PUHZ-SW100VHA-BS.UK PUHZ-SW100VHAR3-BS.UK

R410A PUHZ-SW75VHA-BS.UK PUHZ-SW75VHAR3-BS.UK PUHZ-SW75VHAR4-BS.UK PUHZ-SW100VHA-BS.UK PUHZ-SW100VHAR3-BS.UK SPLIT-TYPE, AIR TO WATER HEAT PUMP SERVICE MANUAL Outdoor unit [Model Name] PUHZ-SW75VHA PUHZ-SW00VHA PUHZ-SW00YHA PUHZ-SW0VHA PUHZ-SW0YHA Salt proof model PUHZ-SW75VHA-BS PUHZ-SW00VHA-BS PUHZ-SW00YHA-BS

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit>

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-SP100JA(L) PEAD-SP125JA(L) PEAD-SP140JA(L) Models PEAD-SP71JA(L) <indoor unit> SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 4 SERVICE MANUAL Series PEAD R4A Models PEAD-SP7JA(L) PEAD-SPJA(L) PEAD-SP5JA(L) PEAD-SPJA(L) NOTE: This manual describes only service data of the indoor

More information

Outdoor unit SERVICE MANUAL

Outdoor unit SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS SPLIT-TYPE, AIR CDITIERS Outdoor unit SERVICE MANUAL R40A November 007 No.OCH49 [model names] PUZ-A8NHA PUZ-A4NHA PUZ-A30NHA PUZ-A36NHA PUZ-A4NHA PUZ-A8NHA-BS PUZ-A4NHA-BS

More information

PUHZ-SHW230YKA SERVICE MANUAL R410A. September 2012 SPLIT-TYPE, AIR TO WATER HEAT PUMP. No. OCH534. [Service Ref.] [Model name] CONTENTS

PUHZ-SHW230YKA SERVICE MANUAL R410A. September 2012 SPLIT-TYPE, AIR TO WATER HEAT PUMP. No. OCH534. [Service Ref.] [Model name] CONTENTS SPLIT-TYPE, AIR TO WATER HEAT PUMP September 202 No. SERVICE MANUAL R40A [Model name] PUHZ-SHW230YKA [Service Ref.] PUHZ-SHW230YKA Note: This manual describes only service data of the outdoor unit. Refer

More information

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A12EA7 PUZ-A12NKA7 PUZ-A12NKA7-BS INDOOR

More information

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7 P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive

More information

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7 P-SERIES SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A24EA7 PUY-A24NHA7 PUY-A24NHA7-BS INDOOR

More information

SERVICE MANUAL PUHZ-ZRP250YKA3.UK R410A. No. OCH680. November 2017 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. Outdoor unit [Model Name]

SERVICE MANUAL PUHZ-ZRP250YKA3.UK R410A. No. OCH680. November 2017 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL R40A November 07 No. Outdoor unit [Model Name] PUHZ-ZRP00YKA3 PUHZ-ZRP50YKA3 [Service Ref.] PUHZ-ZRP00YKA3.UK PUHZ-ZRP50YKA3.UK Note: This manual describes

More information

Outdoor unit SERVICE MANUAL

Outdoor unit SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS SPLIT-TYPE, AIR CDITIERS Outdoor unit SERVICE MANUAL R40A June 007 No.OC367 REVISED EDITI-C [model names] PUZ-A8NHA PUZ-A4NHA PUZ-A30NHA PUZ-A36NHA PUZ-A4NHA PUZ-A8NHA-BS

More information

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7 P-SERIES SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A36EA7 PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR

More information

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS

More information

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7 P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS

More information

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM Job Name: System Reference: : Date: : PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Unobtrusive ceiling-concealed

More information

SERVICE MANUAL. R410A [Model Name]

SERVICE MANUAL. R410A [Model Name] AIR TO WATER HEAT PUMP SERVICE MANUAL R40A [Model Name] PUHZ-W85VHA PUHZ-W85VHA-BS [Service Ref.] PUHZ-W85VHA.UK PUHZ-W85VHAR.UK PUHZ-W85VHAR3.UK PUHZ-W85VHAR4.UK PUHZ-W85VHAR5.UK PUHZ-W85VHA-BS.UK PUHZ-W85VHAR-BS.UK

More information

SERVICE MANUAL. R410A Outdoor unit [Model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. September No.OCH526

SERVICE MANUAL. R410A Outdoor unit [Model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. September No.OCH526 SPLIT-TYPE, HEAT PUMP AIR CDITIERS September 0 No. SERVICE MANUAL R40A Outdoor unit [Model names] PUHZ-SHW80VHA PUHZ-SHWVHA PUHZ-SHWYHA PUHZ-SHW40YHA www.zubadan.ro [Service Ref.] PUHZ-SHW80VHA PUHZ-SHWVHA

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 12 TECHNICAL & SERVICE MANUAL Series SEZ Model name SEZ-KD25VA(L) SEZ-KD35VA(L) SEZ-KDVA(L) SEZ-KDVA(L) SEZ-KD71VA(L) INDOOR UNIT ON/OFF TEMP TEMP.

More information

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1

PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P20VBM-ER1 PKFY-P25VBM-E PKFY-P25VBM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS November No. OCH REVISED EDITI-A TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVBM-E PKFY-PVBM-E PKFY-PVBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-E

More information

SERVICE MANUAL R410A. September 2008 AIR TO WATER HEAT PUMP. No. OCH439 REVISED EDITION-A. [Service Ref.] [model name]

SERVICE MANUAL R410A. September 2008 AIR TO WATER HEAT PUMP. No. OCH439 REVISED EDITION-A. [Service Ref.] [model name] AIR TO WATER HEAT PUMP September 2008 No. OCH439 REVISED EDITI-A SERVICE MANUAL R40A [model name] PUHZ-W50VHA PUHZ-W50VHA-BS PUHZ-W85VHA PUHZ-W85VHA-BS PUHZ-HW2YHA PUHZ-HW2YHA-BS PUHZ-HW40VHA PUHZ-HW40VHA-BS

More information

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. February 2008

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. February 2008 SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE MANUAL R40A Outdoor unit [model names] PUHZ-RPVHA PUHZ-RPVHA PUHZ-RP0VHA PUHZ-RP0VHA PUHZ-RP60VHA PUHZ-RP60VHA PUHZ-RP7VHA PUHZ-RP7VHA PUHZ-RP00VHA PUHZ-RP00VHA

More information

PUHZ-P200YHA PUHZ-P250YHA PUHZ-P200YHA3 PUHZ-P250YHA3

PUHZ-P200YHA PUHZ-P250YHA PUHZ-P200YHA3 PUHZ-P250YHA3 SPLIT-TYPE, HEAT PUMP AIR CDITIERS February 009 No.OCH44 REVISED EDITI-A SERVICE MANUAL R40A Outdoor unit [model names] PUHZ-P00YHA PUHZ-P50YHA PUHZ-P00YHA3 PUHZ-P50YHA3 [Service Ref.] PUHZ-P00YHA PUHZ-P50YHA

More information

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL December No.HWE0 REVISED EDITION-B Indoor unit [Model names] SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KDVAQ SEZ-KDVAQ SEZ-KD71VAQ [Service Ref.] SEZ-KD25VAQ.TH

More information

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK AIR CDITIERS MODELS PQHY-P6YSHM-A PQHY-P700YSHM-A PQHY-P7YSHM-A PQHY-P800YSHM-A PQHY-P8YSHM-A PQHY-P900YSHM-A DATA BOOK WY SERIES DATA G7 HEAT SOURCE UNITS I.WY SERIES. SPECIFICATIS... 2 2. EXTERNAL DIMENSIS...

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL RA December 22 No. OCH REVISED EDITI-C Indoor unit [Model names] PKFY-PVBM-E PKFY-P2VBM-E PKFY-P2VBM-E [Service Ref.] PKFY-PVBM-E PKFY-PVBM-ER2

More information

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L)

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L) SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 2018 SERVICE MANUAL Series PEAD R32/R4A Models PEAD-SM71JA(L) PEAD-SM0JA(L) PEAD-SM125JA(L) PEAD-SM1JA(L) NOTE: This manual describes only service data

More information

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes

TECHNICAL & SERVICE MANUAL. Ceiling Cassettes RESET RESET SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SLH/SL Indoor unit [Model names] SLH-AR SLH-.6AR SLH-AR SL-AR SL-.6AR SL-AR Ceiling Cassettes

More information

SERVICE MANUAL R410A. June 2014 AIR TO WATER HEAT PUMP. No. OCH562. Outdoor unit [Model Name] [Service Ref.] PUHZ-W112VHA PUHZ-W112VHA-BS CONTENTS

SERVICE MANUAL R410A. June 2014 AIR TO WATER HEAT PUMP. No. OCH562. Outdoor unit [Model Name] [Service Ref.] PUHZ-W112VHA PUHZ-W112VHA-BS CONTENTS AIR TO WATER HEAT PUMP June 204 No. SERVICE MANUAL R40A Outdoor unit [Model Name] PUHZ-W2VHA Salt proof model PUHZ-W2VHA-BS [Service Ref.] PUHZ-W2VHA PUHZ-W2VHA-BS Note: This manual describes service data

More information

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

TECHNICAL & SERVICE MANUAL. Wall Mounted. Series PKFY PKFY-P20VAM-A PKFY-P25VAM-A R407C R22 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CDITIERS 00 No. OC TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R07C R Indoor unit [Model names] PKFY-P0VAM-A [Service Ref.] PKFY-P0VAM-A CTENTS INDOOR UNIT. SAFETY PRECAUTI.

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS 005 SERVICE MANUAL Series PEAD R7C/RA Service ref. Models RP35EA() RP50EA RPEA RP7EA RP00EA() RP5EA RPEA NOTE: This manual describes only service data

More information

SERVICE TECHNICAL GUIDE

SERVICE TECHNICAL GUIDE SPLIT-TYPE, HEAT PUMP AIR CDITIERS SERVICE TECHNICAL GUIDE [Model names] PLA-RP AA PKA-RP GAL PKA-RP FAL PCA-RP GA PEA-RP EA PEAD-RP EA PEAD-RP GA [Model names] PUHZ-RP VHA

More information

PUHZ-SHW140YHA PUHZ-SHW230YKA

PUHZ-SHW140YHA PUHZ-SHW230YKA 1 Specifications Model Name PUHZ-SHW1YHA PUHZ-SHWYKA Power supply (phase, cycle, voltage) 3φ, 0V, Hz 3φ, 0V, Hz Max. current A 13.0 6.0 Breaker size A 16 3 Outer casing Galvanized plate Galvanized plate

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC Revision G: Errors in TROUBLESHOOTING have been corrected. Please void OB455 REVISED EDITION-F. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-G Models MUZ-GB50VA - E1 MUZ-GB50VA

More information

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1

Floor Standing PFFY-P20VKM-E PFFY-P20VKM-ER1 PFFY-P25VKM-E PFFY-P25VKM-ER1 PFFY-P32VKM-E PFFY-P32VKM-ER1 PFFY-P40VKM-E PFFY-P40VKM-ER1 SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL November 008 No. OC0 REVISED EDITI-A Series PFFY Indoor unit [Model names] PFFY-P0VKM-E PFFY-PVKM-E PFFY-PVKM-E PFFY-P0VKM-E Floor Standing

More information

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7 P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS

More information

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 2011 No. OCH452 REVISED EDITION-A Indoor unit [Model names] PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL [Service Ref.] PKA-RP60KAL.TH

More information

MUH-24RV - MSH-30RV -

MUH-24RV - MSH-30RV - SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.

More information

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS December No. OCH7 REVISED EDITI-B TECHNICAL & SERVICE MANUAL RA R7C R Indoor unit [Model names] PKFY-PVKM-E PKFY-PVKM-E [Service Ref.] PKFY-PVKM-E.TH PKFY-PVKM-ER.TH

More information

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH

SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH SLZ-KF60VA.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 205 No. Indoor unit [Model Name] SLZ-KF25VA SLZ-KF35VA SLZ-KF50VA SLZ-KF60VA [Service Ref.] SLZ-KF25VA.TH SLZ-KF35VA.TH SLZ-KF50VA.TH

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

PKA-RP35HAL PKA-RP50HAL

PKA-RP35HAL PKA-RP50HAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS March 2009 No. OCH453 SERVICE MANUAL Indoor unit [Model names] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP50HAL NOTE: This

More information

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision : A MXZ-A5/A7VA- MXZ-A0/A5VA- Please void OB77 E E has been added. has been added. OUTDOOR UNIT SERVICE MANUAL HFC utilized R0A No. OB77 REVISED EDITION-A

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7 P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS SUBMITTAL DATA: SLZ-KA9NA......... 9, BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction

More information

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH

PLFY-P15VCM-E3.TH PLFY-P20VCM-E3.TH PLFY-P25VCM-E3.TH PLFY-P32VCM-E3.TH PLFY-P40VCM-E3.TH SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL June 04 No. Indoor unit [Model Name] PLFY-PVCM-E PLFY-P0VCM-E PLFY-PVCM-E PLFY-PVCM-E PLFY-P40VCM-E R40A [Service Ref.] PLFY-PVCM-E.TH PLFY-P0VCM-E.TH

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A Revision E: MUZ-GB50VA- E3 has been added. Please void OB455 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-E Wireless type Models MUZ-GB50VA - E1 MUZ-GB50VA -

More information

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7 P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER

PKA-RP35HAL PKA-RP35HALR1 PKA-RP35HALR1-ER PKA-RP50HAL PKA-RP50HALR1 PKA-RP50HALR1-ER SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL July 2014 No. OCH453 REVISED EDITION-A Indoor unit [Model Name] PKA-RP35HAL PKA-RP50HAL [Service Ref.] PKA-RP35HAL PKA-RP35HALR1

More information

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008

SERVICE MANUAL PCH-P50GAH PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH. May 2008 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS SERVICE MANUAL May 008 No. OC8 REVISED EDITION-B Indoor unit [Model names] [Service Ref.] PCA-RP0A PCA-RP0A PCA-RP0A# PCA-RP0A PCA-RP0A

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

SUZ-A09VR.TH SUZ-A12VR.TH SUZ-A18VR.TH SUZ-A24VR.TH

SUZ-A09VR.TH SUZ-A12VR.TH SUZ-A18VR.TH SUZ-A24VR.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS.OC4 REVISED EDITION-A TECHNICAL & SERVICE MANUAL R40A [model names] SUZ-A09VR SUZ-A2VR SUZ-AVR SUZ-AVR [Service Ref.] SUZ-A09VR.TH SUZ-A2VR.TH SUZ-AVR.TH SUZ-AVR.TH

More information

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV -

SERVICE MANUAL MUX-A22WV - E1 HFC. Multi system type Model SPLIT-TYPE, AIR CONDITIONER. No. OB318 R410A CONTENTS. Revision A: MUX-A22WV - SPLIT-TYPE, AIR CDITIER Revision A: MUX-AWV - E can be connected to MSC-A07/AYV - E. PARTS LIST has partially modified. Please void OB8. SERVICE MANUAL Multi system type Model HFC utilized R40A. OB8 REVISED

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL AIR CONDITIONERS 0 TECHNICAL & SERVICE MANUAL Models P0VMA(L)-E, P5VMA(L)-E, PVMA(L)-E, P40VMA(L)-E, P50VMA(L)-E, P6VMA(L)-E P7VMA(L)-E P80VMA(L)-E P00VMA(L)-E P5VMA(L)-E P40VMA(L)-E Safety Precautions

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) 6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH

PKA-RP60FAL PKA-RP71FAL PKA-RP100FAL PKH-P60FALH PKH-P71FALH PKH-P100FALH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS May 005 No.OC33 SERVICE MANUAL Indoor unit [Model names] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL [Service Ref.] PKA-RP60FAL PKA-RP7FAL PKA-RP00FAL

More information

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Inverter-controlled multi system Models E MXZ-A8WV - E MXZ-A6WV - MXZ-AWV - E HFC utilized R40A No. OB9 Indication of model name MXZ-A8WV - E CONTENTS.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS 004 TECHNICAL & SERVICE MANUAL R40A Outdoor unit [model names] PUHZ-RP.6VHA PUHZ-RPVHA PUHZ-RP.5VHA PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA [Service Ref.] PUHZ-RP.6VHA

More information

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E

PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E SPLIT-TYPE, HEAT PUMP AIR CDITIERS July 00 No. OC0 REVISED EDITI-A TECHNICAL & SERVICE MANUAL Series PKFY Wall Mounted R0A R0C R [Model names] PKFY-PVGM-E PKFY-P0VGM-E PKFY-P0VGM-E [Service

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS April 2007

SERVICE MANUAL. R410A Outdoor unit [model names] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS April 2007 SPLIT-TYPE, HEAT PUMP AIR CDITIERS SPLIT-TYPE, AIR CDITIERS April 007 No.OC379 REVISED EDITI-C SERVICE MANUAL R0A Outdoor unit [model names] PU-P7VHA PU-P7YHA PU-P00VHA PU-P00YHA PU-P5YHA PU-P0YHA PUH-P7VHA

More information

SERVICE MANUAL. Series PEA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS CONTENTS

SERVICE MANUAL. Series PEA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS CONTENTS SPLIT-TYPE, HEAT PUMP AIR CDITIERS 0 SERVICE MANUAL Series PEA Model name PEA-RP00GAQ PEA-RP0GAQ PEA-RP00GAQ PEA-RP00GAQ This manual describes only service data of the indoor units. CTENTS

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SPLIT-TYPE, AIR CONDITIONERS TECHNICAL & SERVICE MANUAL R07C Outdoor unit [model names] No.OC6 REVISED EDITION-B PUH-PVGAA PUH-P.6VGAA PUH-P.6YGAA PUH-PVGAA PUH-PYGAA

More information

AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A

AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A AIR CONDITIONING SYSTEMS MODEL CMH-WM-V-A CONTENTS CMH-WM-V-A 1. SPECIFICATIONS... 2 2. EXTERNAL DIMENSIONS... 5 3. CENTER OF GRAVITY... 7 4. ELECTRICAL WIRING DIAGRAMS... 8 5. SOUND LEVELS... 9 5-1. Sound

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE,HEAT PUMP AIR CDITIERS 1997 No. OC135 TECHNICAL & SERVICE MANUAL Series PCH Ceiling Suspended Indoor unit [Models names] [Service Ref.] PCH-2GKHA PCH-2.5GKHA PCH-3GKHA PCH-4GKHSA PCH-5GKHSA

More information

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) AIR CONDITIONING SYSTEMS MODEL PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F) DATA BOOK Contents!. General Cautions. Indoor Unit Line-up. Temperature range. Notes on selecting equipments () Notes on using the Fresh

More information

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type 11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P32VMS-E, PEFY-P63VMS-E

PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P32VMS-E, PEFY-P63VMS-E 2006 Air-Conditioners TECHNICAL & SERVICE MANUAL Models PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P2VMS-E, PEFY-P6VMS-E For use with R40A, R407C, & R22 Safety Precautions Read before

More information

Compact 4-way Cassette ( ) Type

Compact 4-way Cassette ( ) Type E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference

More information