DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Size: px
Start display at page:

Download "DC INVERTER SPLIT SYSTEM AIR CONDITIONER"

Transcription

1 AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No Outdoor Model No. CU-KS30NKUA CU-KS36NKUA Product Code No Indoor Unit Outdoor Unit CS-KS30NKU CS-KS36NKU CU-KS30NKUA CU-KS36NKUA IMPORTANT These air conditioners employ new refrigerant R40A. Pay special attention when servicing the unit. REFERENCE NO. SM700875

2 SAFETY PRECAUTIONS Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly. Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them. Symbol Indication : This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described. : This symbol indicates the item to be prohibited. In or close to this circle, a prohibited item is described. : This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described. After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user. Warning Before performing an overhaul, disconnect the power plug or power cable from the unit. Performing the work with the power supplied to the unit, may cause an electric shock. When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed, do not touch the charging section. Doing so may cause an electric shock. Prohibit For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock. Do not perform repair work on the electric sections with wet hands. Doing so may cause an electric shock. Do not start or stop the air conditioner by means of connecting or disconnecting the power plug. Doing so may cause an electric shock or fire. When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools. Incorrect or poor repair work may cause an electric shock or fire. Never modify the unit. Doing so may cause an electric shock or fire. Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit. Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire. Prohibit Prohibit Prohibit Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration. Failure to do so may cause an electric shock, overheating or fire. Make sure that there is no dust on or slack in the power plug and insert fully into the socket. Dust or incomplete connections may cause an electric shock or fire. Do not damage or process the power cord, as it may cause an electric shock or fire. Prohibit For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire. After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire. 2

3 Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." When the welded section of the compressor intake or discharge pipe is to be disconnected, perform it in a well-ventilated place after sufficiently recovering the refrigerant gas. Any residue gas may jet out refrigerant or refrigerating machine oil, which may cause an injury. Prohibit When the work is to be performed in a high place (About 2 meters or more), make sure to wear a safety helmet, gloves and safety belt. Insufficient safety gear may cause a serious injury in case of a fall. When the unit is to be relocated, confirm that the new installation location has sufficient strength for the weight of the unit. Insufficient strength of the installation location and incomplete installation work may cause an injury due to the unit falling. When the remote controller batteries are replaced, dispose of the old batteries out of the reach of children. If a child swallows a battery, make sure that the child gets immediate medical attention. Caution Do not wash the air conditioner with water, as this may cause an electric shock or fire. Prohibit For the repair work in places with high humidity or moisture, make sure to ground the unit. Failure to do so may cause an electric shock. Confirm that the component attachment position, wiring condition, soldering condition and connector connection are normal. If not, it may cause overheating or fire. Confirm that the temperature around the compressor is not too high, and then perform the repair work. Failure to do so may cause a burn. Perform welding work in a place with good ventilation. If the work is performed in a poorly ventilated area, it might cause a lack of oxygen. If the installation plate or attachment frame has deteriorated due to corrosion, etc., replace it. Failure to do so may cause an injury due to the unit falling. When the cleaning is to be performed, make sure to turn off the power and pull out the plug. Touching the fan that is rotating at high speed may result in an injury. When the indoor unit is to be removed, do not place it on an incline. Doing so may cause wet furniture because water left inside may trickle down. Prohibit Do not hold the sharp end of the unit or the aluminum fins, as it may cause an injury to your hand or finger. Prohibit After repairs, make sure to measure the insulation resistance and confirm that the value is Mohm or more. Any insulation error may cause an electric shock. After repairs, make sure to check the drainage of the indoor unit. Inappropriate drainage may cause wet furniture and floors due to water leakage. 3

4 Table of Contents SAFETY PRECAUTIONS... Page 2 TABLE OF CONTENTS. OPERATING RANGE SPECIFICATIONS 2-. Unit Specifications Major Component Specifications Other Component Specifications DIMENSIONAL DATA REFRIGERANT FLOW DIAGRAM 4-. Refrigerant Flow Diagram PERFORMANCE DATA 5-. Temperature Charts Cooling Capacity Cooling Capacity (Low Ambient) Air Throw Distance Charts ELECTRICAL DATA 6-. Electrical Characteristics 6-2. Electric Wiring Diagrams 7. FUNCTIONS 7-. Operation Functions 7-2. Protective Functions TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 8-. Precautions before Performing Inspection or Repair Method of Self-Diagnostics Checking the Indoor and Outdoor Units Trouble Diagnosis of Fan Motor Noise Malfunction and Electromagnetic Interference

5 Page 9. CHECKING ELECTRICAL COMPONENTS 9-. Measurement of Insulation Resistance Checking Continuity of Fuse on PCB Ass'y REFRIGERANT R40A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 0-. Characteristics of New Refrigerant R40A Checklist before Servicing Tools Specifically for R40A Tubing Installation Procedures In Case of Compressor Malfunction In Case Refrigerant is Leaking Charging Additional Refrigerant Retro-Fitting Existing Systems APPENDIX A Operating Instructions... A- APPENDIX B INSTALLAION INSTRUCTIONS... A-2 5

6 . OPERATING RANGE Cooling Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 F DB / 7 F WB 5 F DB Minimum 67 F DB / 57 F WB 0 F DB 6

7 2. SPECIFICATIONS 2-. Unit Specifications Indoor Unit Outdoor Unit Performance Electrical Rating Features Dimensions & Weight Voltage Rating CS-KS30NKU CU-KS30NKUA Total Capacity BTU/h kw 30, ( 0,900 to 30,600 ) ( 3.2 to 9.0 ) Sensible Capacity BTU/h 8,600 Latent Capacity BTU/h 2,000 Air Circulation (Hi/Me/Lo) ft 3 /min (m 3 /h) 630 (,070) / 530 (90) /42 (700) Moisture Removal (High) Pints/h 9.57 Available Voltage Range V 87 to 253 Running Amperes Power Input A W 6.5 3,290 ( 5.0 to 6.5 ) (,000 to 3,290 ) Power Factor % 87 EER BTU/h/W 9.30 SEER BTU/Wh 6.0 Compressor Locked Rotor Amperes A 3.0 Fuse or Circuit Breaker Capacity A 35 Controls / Temperature Control Microprocessor / I.C. Thermister Control Unit Wireless Remote Control Unit Timer 24-Hour ON or OFF Timer, -Hour OFF Timer Fan Speeds Indoor / Outdoor Auto and 3 steps / Auto (Hi, Me, Lo) Airflow Direction (Indoor) Horizontal Manual Vertical Auto Air Filter Compressor Washable, Anti-Mold DC Twin Rotary (Inverter) Refrigerant / Amount charged at shipment Ibs (g) R40A / 6.5 (2,950) Refrigerant Control Electric Expansion Valve Operation Sound (*Qt = Quiet mode) Indoor : Hi/Me/Lo/Qt* Outdoor : Hi db-a db-a 49 / 44 / 39 / Refrigerant Tubing Connections Flare Type Max. allowable tubing length at shipment ft (m) 64 (50) Refrigerant Narrow tube inch (mm) 3/8 (9.52) Tube Diameter Wide tube inch (mm) 5/8 (5.88) Refrigerant Tube Kit Optional Unit Dimensions Height Width Depth Package Dimensions Height Width Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m 3 ) Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F DB / 67 F WB Outdoor air temperature 95 F DB / 75 F WB Indoor Unit 2-7/ /8 4-3/32 (30,40 380) 32.0 (4.5) 39.7 (8.0) 4.59 (0.3) 230V Single-Phase 60Hz Cooling Outdoor Unit < 230V > -3/6 4-5/6 9-/6 35-3/6 37-/32 3-3/8 (300, ) ( ) 42-3/ /8 (,076,06 46) 83.0 (83.0) (93.0) 5.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 7

8 Indoor Unit Outdoor Unit Performance Electrical Rating Features Dimensions & Weight Voltage Rating CS-KS30NKU CU-KS30NKUA Total Capacity BTU/h kw Sensible Capacity BTU/h Latent Capacity BTU/h Air Circulation (Hi/Me/Lo) ft 3 /min (m 3 /h) Moisture Removal (High) Pints/h Available Voltage Range V Running Amperes A Power Input W Power Factor % EER BTU/h/W SEER BTU/Wh Compressor Locked Rotor Amperes A Fuse or Circuit Breaker Capacity A Controls / Temperature Control Control Unit Timer Fan Speeds Indoor / Outdoor Airflow Direction (Indoor) Horizontal Vertical Air Filter Compressor Refrigerant / Amount charged at shipment Ibs (g) Refrigerant Control Operation Sound (*Qt = Quiet mode) Indoor : Hi/Me/Lo/Qt* Outdoor : Hi db-a db-a Refrigerant Tubing Connections Max. allowable tubing length at shipment ft (m) Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tube Kit Unit Dimensions Height Width Depth Package Dimensions Height Width Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m 3 ) 208V Single-Phase 60Hz 30,600 ( 0,900 to 30,600 ) 9.0 ( 3.2 to 9.0 ) 8,600 2, (,070) / 530 (90) /42 (700) 8.0 3,290 Indoor Unit 2-7/ /8 4-3/32 (30,40 380) 32.0 (4.5) 39.7 (8.0) 4.59 (0.3) Cooling to 253 ( 5.0 to 8.0 ) (,000 to 3,290 ) Microprocessor / I.C. Thermister Wireless Remote Control Unit 24-Hour ON or OFF Timer, -Hour OFF Timer Auto and 3 steps / Auto (Hi, Me, Lo) Manual Auto Washable, Anti-Mold DC Twin Rotary (Inverter) R40A / 6.5 (2,950) Electric Expansion Valve 49 / 44 / 39 / Flare Type 64 (50) 3/8 (9.52) 5/8 (5.88) Optional Outdoor Unit < 208V > -3/6 4-5/6 9-/6 35-3/6 37-/32 3-3/8 (300, ) ( ) 42-3/ /8 (,076,06 46) 83.0 (83.0) (93.0) 5.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F DB / 67 F WB Outdoor air temperature 95 F DB / 75 F WB 8

9 Indoor Unit Outdoor Unit Performance Electrical Rating Features Dimensions & Weight Voltage Rating CS-KS36NKU CU-KS36NKUA Total Capacity BTU/h kw Sensible Capacity BTU/h Latent Capacity BTU/h Air Circulation (Hi/Me/Lo) ft 3 /min (m 3 /h) Moisture Removal (High) Pints/h Available Voltage Range V Running Amperes A Power Input W Power Factor % EER BTU/h/W SEER BTU/Wh Compressor Locked Rotor Amperes A Fuse or Circuit Breaker Capacity A Controls / Temperature Control Control Unit Timer Fan Speeds Indoor / Outdoor Airflow Direction (Indoor) Horizontal Vertical Air Filter Compressor Refrigerant / Amount charged at shipment Ibs (g) Refrigerant Control Operation Sound (*Qt = Quiet mode) Indoor : Hi/Me/Lo/Qt* Outdoor : Hi db-a db-a Refrigerant Tubing Connections Max. allowable tubing length at shipment ft (m) Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tube Kit Unit Dimensions Height Width Depth Package Dimensions Height Width Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m 3 ) 230V Single-Phase 60Hz 34,000 ( 0,900 to 34,000 ) 0.0 ( 3.2 to 0.0 ) 20,700 3, (,070) / 530 (90) /42 (700) ,000 Indoor Unit 2-7/ /8 4-3/32 (30,40 380) 32.0 (4.5) 39.7 (8.0) 4.59 (0.3) Cooling to 253 ( 5.0 to 20.0 ) (,000 to 4,000 ) Microprocessor / I.C. Thermister Wireless Remote Control Unit 24-Hour ON or OFF Timer, -Hour OFF Timer Auto and 3 steps / Auto (Hi, Me, Lo) Manual Auto Washable, Anti-Mold DC Twin Rotary (Inverter) R40A / 6.5 (2,950) Electric Expansion Valve 49 / 44 / 39 / Flare Type 64 (50) 3/8 (9.52) 5/8 (5.88) Optional Outdoor Unit < 230V > -3/6 4-5/6 9-/6 35-3/6 37-/32 3-3/8 (300, ) ( ) 42-3/ /8 (,076,06 46) 83.0 (83.0) (93.0) 5.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F DB / 67 F WB Outdoor air temperature 95 F DB / 75 F WB 9

10 Indoor Unit Outdoor Unit Performance Electrical Rating Features Dimensions & Weight Voltage Rating CS-KS36NKU CU-KS36NKUA Total Capacity BTU/h kw Sensible Capacity BTU/h Latent Capacity BTU/h Air Circulation (Hi/Me/Lo) ft 3 /min (m 3 /h) Moisture Removal (High) Pints/h Available Voltage Range V Running Amperes A Power Input W Power Factor % EER BTU/h/W SEER BTU/Wh Compressor Locked Rotor Amperes A Fuse or Circuit Breaker Capacity A Controls / Temperature Control Control Unit Timer Fan Speeds Indoor / Outdoor Airflow Direction (Indoor) Horizontal Vertical Air Filter Compressor Refrigerant / Amount charged at shipment Ibs (g) Refrigerant Control Operation Sound (*Qt = Quiet mode) Indoor : Hi/Me/Lo/Qt* Outdoor : Hi db-a db-a Refrigerant Tubing Connections Max. allowable tubing length at shipment ft (m) Refrigerant Narrow tube inch (mm) Tube Diameter Wide tube inch (mm) Refrigerant Tube Kit Unit Dimensions Height Width Depth Package Dimensions Height Width Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m 3 ) 208V Single-Phase 60Hz 34, ,000 Indoor Unit 2-7/ /8 4-3/32 (30,40 380) 32.0 (4.5) 39.7 (8.0) 4.59 (0.3) Cooling ( 0,900 to 34,000 ) ( 3.2 to 0.0 ) 20,700 3, (,070) / 530 (90) /42 (700) to 253 ( 5.0 to 2.9 ) (,000 to 4,000 ) Microprocessor / I.C. Thermister Wireless Remote Control Unit 24-Hour ON or OFF Timer, -Hour OFF Timer Auto and 3 steps / Auto (Hi, Me, Lo) Manual Auto Washable, Anti-Mold DC Twin Rotary (Inverter) R40A / 6.5 (2,950) Electric Expansion Valve 49 / 44 / 39 / Flare Type 64 (50) 3/8 (9.52) 5/8 (5.88) Optional Outdoor Unit < 208V > -3/6 4-5/6 9-/6 35-3/6 37-/32 3-3/8 (300, ) ( ) 42-3/ /8 (,076,06 46) 83.0 (83.0) (93.0) 5.88 (0.45) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: Rating conditions are: Cooling: Indoor air temperature 80 F DB / 67 F WB Outdoor air temperature 95 F DB / 75 F WB 0

11 2-2. Major Component Specifications Indoor Unit Indoor Unit CS-KS30NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-KS30NKU Microprocessor 250V 3A Fan Type Q'ty... Dia. and Length inch (mm) Cross-Flow... D3-5/6 / L32- (D00/L838) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (20 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 F (25 C)) Heat Exchanger Coil Coil Rows Fins Per inch Face Area W Ohm Micro F VAC Ohm ft 2 (m 2 ) DC Motor SIC-4CVJ-D , Internal Controller Yes Yes - - Stepping Motor 24BYJ DC 2V Each Pair of Terminal : 200 +/- 7% Aluminum Plate Fin / Copper Tube and (0.423) DATA SUBJECT TO CHANGE WITHOUT NOTICE.

12 Indoor Unit CS-KS36NKU Control PCB Part No. Controls Control Circuit Fuse CB-CS-KS36NKU Microprocessor 250V 3A Fan Type Q'ty... Dia. and Length inch (mm) Cross-Flow... D3-5/6 / L32- (D00/L838) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (20 C)) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Flap Motor Type Model Rating Coil Resistance (Ambient Temp. 77 F (25 C)) Heat Exchanger Coil Coil Rows Fins Per inch Face Area W Ohm Micro F VAC Ohm ft 2 (m 2 ) DC Motor SIC-4CVJ-D , Internal Controller Yes Yes - - Stepping Motor 24BYJ DC 2V Each Pair of Terminal : 200 +/- 7% Aluminum Plate Fin / Copper Tube and (0.423) DATA SUBJECT TO CHANGE WITHOUT NOTICE. 2

13 Outdoor Unit Outdoor Unit CU-KS30NKUA P.C.Board Part No. Controls Circuit Fuse Control P.C.B CR-C3082-F Microprocessor 400V 3.5A Noise Filer P.C.B POW-CH3082-B2-250V 25A H.I.C.Board HIC-CH3072R-C - - Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 77 F (25 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC DC Twin Rotary (Hermetic) C-9RVN273H0H / 2,250W FV68S (,400) T - R : 0.69 T - S : 0.69 R - S : 0.69 Yes Yes Yes CS-7L0 Open : 230 F (0 C), Close : 203 F (95 C) V 30W Fan Type Q'ty... Dia. inch (mm) Propeller... D9-9/32 (D490) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (20 C)) Safety Device Type Over- Current Protection Over- Heat Protection Run Capacitor W Ohm Micro F VAC DC Motor SIC-7FW-D820-4A Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube Face Area ft 2 (m 2 ) 8.05 (0.748) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 3

14 Outdoor Unit CU-KS36NKUA P.C.Board Part No. Controls Circuit Fuse Control P.C.B CR-C3682-F Microprocessor 400V 3.5A Noise Filer P.C.B POW-CH3082-B2-250V 25A H.I.C.Board HIC-CH3072R-C - - Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Pints (cc) Coil Resistance (Ambient Temp. 77 F (25 C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Crankcase Heater Micro F VAC DC Twin Rotary (Hermetic) C-9RVN273H0H / 2,500W FV68S (,400) T - R : 0.69 T - S : 0.69 R - S : 0.69 Yes Yes Yes CS-7L0 Open : 230 F (0 C), Close : 203 F (95 C) V 30W Fan Type Q'ty... Dia. inch (mm) Propeller... D9-9/32 (D490) Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 F (20 C)) Safety Device Type Over- Current Protection Over- Heat Protection Run Capacitor W Ohm Micro F VAC DC Motor SIC-7FW-D820-4A Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fins per inch Aluminum Plate Fin / Copper Tube Face Area ft 2 (m 2 ) 8.05 (0.748) External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 4

15 2-3. Other Component Specifications Indoor Unit CS-KS30NKU CS-KS36NKU Outdoor Unit CU-KS30NKUA CU-KS36NKUA Indoor air temp sensor (Model:KTEC ) Indoor heat exchanger sensor (Model:PTM-D5H-S6-) Compressor temp sensor (Model:TKS335B) Resistance (k ohm) (0) (5) (20) (25) (30) (35) (40) Temperature F ( C) Resistance (k ohm) (0) (0) (20) (30) (40) (50) (60) (70) (80) (90) Temperature F ( C) Outdoor air temp sensor (Model:TKS295B) Outdoor heat exchanger sensor (Model:TKS334B) Heat sink temp sensor (HIC Board) (Model:TKS36B) 40 Resistance (k ohm) (-20)(-5)(-0) (-5) (0) (5) (0) (5) (20) Temperature F ( C) 5

16 3. DIMENSIONAL DATA Indoor Unit CS-KS30NKU CS-KS36NKU 4-9/6-5/32 dia. 3-5/32 4-5/6 (065) 9-/6 (230) (3/32) 2-3/32 25/32-27/32-3/ /32 Wide tube dia. 5/8" (5.88) 5-27/32 Narrow tube dia. 3/8" (9.52) 5-/2 5-/8 7-23/32 9-3/32 3-3/4 3-3/4 7-7/8 2-/6 6-7/32 6-/32 7-5/6 9-9/6 5-3/6 6-/32 7-2/ /8 dia. 3-5/32-3/6 5/6 2-3/4-3/6 (300) -7/8 23/32 4-9/6-7/8 7-23/32 2-3/4 5-9/6-9/32 2-3/8 2-3/8 2-5/8 3-3/8 7/6 2-5/8 Unit: inch(mm) ( ) 6

17 Outdoor Unit CU-KS30NKUA CU-KS36NKUA -3/6 7/6 2-5/32 Unit: inch(mm) ( ) 3-9/32 4-/32 4-/ /32-5/6-27/32-3/6 6-23/32 9/32 4-3/4 3/32 2/32 6-/6 25-3/32 4-/32 4-/8 8-5/8 2-5/6 2-5/6 2-3/8 /2 /2 37-/32 (940) 3/4 2-3/8 2-ID:-/4 holes (holes for drain) Of the 4-ID:-/4 holes, use of 2 holes specified for drain use to install the port. Use rubber plugs to seal the remaining 3 holes. Refrigerant tubing joint (Liquid tube) Flare connection dia.3/8" (9.52) Refrigerant tubing joint (Gas tube) Flare connection dia.5/8" (5.88) 2-3/8 3-3/8 2-7/32 3/4 Wiring outlet (knock-out holes dia.-3/8, -3/32, 7/8, /2) 2-25/32-5/6 4-/32-27/32-3/6 Wiring outlet (knock-out holes dia.-3/8, -3/32, 7/8, /2) 2-5/32 2-7/32-3/32 -/ /6 (90) 23/32 3/32 3-3/8 (340) 4-3/32 6-5/32 7

18 4. REFRIGERANT FLOW DIAGRAM 4-. Refrigerant Flow Diagram Indoor Unit CS-KS30NKU CS-KS36NKU Outdoor Unit CU-KS30NKUA CU-KS36NKUA Indoor unit Outdoor unit Wide tube O.D 5/8" (5.88 mm) Wide tube service valve Muffler Sub Accumulator Main Accumulator High pressure switch H.P. Heat exchanger Heat exchanger Compressor Narrow tube Narrow tube service valve Electric expansion valve M Cooling cycle O.D. 3/8" (9.52 mm) Strainer 8

19 5. PERFORMANCE DATA 5-. Temperature Charts Indoor Unit CS-KS30NKU Outdoor Unit CU-KS30NKUA Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) () Low pressure performance chart Indoor discharge air temperature F( C) Low pressure at wide tube service valve Operating current (A) psig(mpag) 74 (.2) 59 (.) 45 (.0) 3 (0.9) 7 (0.8) 04 (0.7) -4 (-20) 5 (-5) 4 (-0) 23 (-5) (2) Operating current performance chart (-20) 5 (-5) 4 (-0) 23 (-5) (3) Indoor discharge air performance chart 64.4 (8) 60.8 (6) 57.2 (4) 53.6 (2) 50.0 (0) 46.4 (8) 42.8 (6) 32 (0) 32 (0) 4 (5) 50 (0) 59 (5) Outdoor inlet air DB temp. F( C) (5) (0) (5) Outdoor inlet air DB temp. F( C) 68 (20) 68 (20) Lo fan Indoor Air Temp.86 F (30 C) Lo fan Lo fan 80 F (27 C) 75 F (24 C) 77 (25) 77 (25) 86 (30) Indoor Air Temp.86 F (30 C) 80 F (27 C) 75 F (24 C) Indoor Air Temp.86 F (30 C) 80 F (27 C) 80 F (27 C) 75 F (24 C) 75 F (24 C) 86 (30) Hi Fan Hi Fan Hi Fan 95 (35) 95 (35) 04 (40) 04 (40) -4 (-20) 5 (-5) 4 (-0) 23 (-5) 32 (0) (5) (0) (5) Outdoor inlet air DB temp. F( C) 68 (20) 77 (25) 86 (30) 95 (35) 04 (40) NOTE Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. 9

20 Indoor Unit CS-KS36NKU Outdoor Unit CU-KS36NKUA Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) () Low pressure performance chart Indoor discharge air temperature F( C) Low pressure at wide tube service valve Operating current (A) psig(mpag) 74 (.2) 59 (.) 45 (.0) 3 (0.9) 7 (0.8) 04 (0.7) -4 (-20) 5 (-5) 4 (-0) 23 (-5) (2) Operating current performance chart (-20) 5 (-5) 4 (-0) 23 (-5) (3) Indoor discharge air performance chart 64.4 (8) 60.8 (6) 57.2 (4) 53.6 (2) 50.0 (0) 46.4 (8) 42.8 (6) 32 (0) 32 (0) 4 (5) 50 (0) 59 (5) Outdoor inlet air DB temp. F( C) (5) (0) (5) Outdoor inlet air DB temp. F( C) 68 (20) 68 (20) Lo fan Indoor Air Temp.86 F (30 C) Lo fan Lo fan 77 (25) 77 (25) 80 F (27 C) 80 F (27 C) 75 F (24 C) 80 F (27 C) Indoor Air Temp.86 F (30 C) 75 F (24 C) Indoor Air Temp.86 F (30 C) 80 F (27 C) 75 F (24 C) 86 (30) 86 (30) Hi Fan Hi Fan Hi Fan 95 (35) 95 (35) 04 (40) 04 (40) -4 (-20) 5 (-5) 4 (-0) 23 (-5) 32 (0) (5) (0) (5) Outdoor inlet air DB temp. F( C) 68 (20) 77 (25) 86 (30) 95 (35) 04 (40) NOTE Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. 20

21 5-2. Cooling Capacity Indoor Unit : CS-KS30NKU Outdoor Unit : CU-KS30NKUA Power Supply : 230V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 30,600 BTU/h AIR FLOW RATE: 630 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) WB DB (8.3) (23.9) (29.4) (35.0) (40.6) (46.) TC 26,540 27,20 27,70 27,90 24,890 7,30 CI (22.2) SHC 9,90 9,430 9,800 9,920 8,330 4, (24.4) SHC 2,50 2,880 22,20 22,250 20,660 6,990 (5.0) 80 (26.7) SHC 23,960 24,330 24,570 24,690 23,00 7,30 84 (28.9) SHC 26,280 26,650 26,890 27,020 24,890 7,30 88 (3.) SHC 26,540 27,20 27,70 27,90 24,890 7,30 TC 3,580 30,90 30,60 29,630 25,270 7,560 CI (22.2) SHC 8,330 7,970 7,600 7,360 5,50, (24.4) SHC 20,660 20,290 9,920 9,680 7,480 4,050 (7.2) 80 (26.7) SHC 23,00 22,740 22,370 22,20 20,050 6, (28.9) SHC 25,430 25,060 24,690 24,450 22,370 7, (3.) SHC 27,750 27,50 27,020 26,770 24,690 7,560 TC 32,420 3,780 3,050 # 30,600 25,550 7,760 CI (22.2) SHC 5,50 4,790 4,420 4,300 2,00 8, (24.4) SHC 7,480 7,0 6,870 6,620 4,420,240 (9.4) 80 (26.7) SHC 9,920 9,560 9,30 9,070 6,870 3, (28.9) SHC 22,250 22,000 2,640 2,390 9,90 6,00 88 (3.) SHC 24,570 24,330 23,960 23,70 2,50 7,760 TC 33,30 32,540 3,840 3,490 25,70 7,880 CI (22.2) SHC,730,480,20,000 8,670 5, (24.4) SHC 4,050 3,80 3,440 3,320,20 8,30 (2.7) 80 (26.7) SHC 6,500 6,250 5,890 5,770 3,560 0, (28.9) SHC 8,820 8,580 8,330 8,20 5,890 3, (3.) SHC 2,50 20,900 20,660 20,530 8,20 5,400 TC 33,630 33,090 32,430 32,90 25,730 7,900 CI (24.4) SHC 0,750 0,50 0,260 0,40 7,940 5,370 (23.9) 80 (26.7) SHC 3,200 2,950 2,70 2,590 0,380 7, (28.9) SHC 5,520 5,280 5,030 5,030 2,70 0,40 88 (3.) SHC 7,840 7,720 7,480 7,360 5,030 2,590 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (26.7 C) DB / 67 F (9.4 C) WB : Outdoor Ambient Temp. 95 F (35 C) DB 2. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 3. Above data represents the value when the operation frequency of a compressor is fixed. 2

22 Indoor Unit : Outdoor Unit : Power supply : CS-KS36NKU CU-KS36NKUA 230V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: 34,000 BTU/h AIR FLOW RATE: 630 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) WB DB (8.3) (23.9) (29.4) (35.0) (40.6) (46.) TC 27,450 28,40 28,840 29,040 24,650 6,770 CI (22.2) SHC 9,680 20,050 20,40 20,530 8,20 4, (24.4) SHC 22,000 22,370 22,740 22,860 20,530 6,740 (5.0) 80 (26.7) SHC 24,450 24,820 25,80 25,300 22,980 6, (28.9) SHC 26,770 27,40 27,50 27,630 24,650 6, (3.) SHC 27,450 28,40 28,840 29,040 24,650 6,770 TC 35,00 34,360 33,600 33,00 24,850 6,90 CI (22.2) SHC 20,70 9,800 9,30 9,070 5,030, (24.4) SHC 22,490 22,20 2,760 2,390 7,360 3,80 (7.2) 80 (26.7) SHC 24,940 24,570 24,200 23,840 9,800 6, (28.9) SHC 27,260 26,890 26,530 26,280 22,20 6,90 88 (3.) SHC 29,580 29,220 28,850 28,60 24,450 6,90 TC 35,720 35,20 34,400 # 34,000 24,930 6,970 CI (22.2) SHC 6,620 6,380 6,00 5,890,730 8, (24.4) SHC 9,070 8,700 8,330 8,20 4,80,000 (9.4) 80 (26.7) SHC 2,50 2,50 20,900 20,660 6,620 3, (28.9) SHC 23,840 23,590 23,230 22,980 8,940 5, (3.) SHC 26,60 25,920 25,550 25,300 2,270 6,970 TC 36,270 35,70 35,040 34,780 24,870 6,950 CI (22.2) SHC 3,070 2,830 2,460 2,340 8,430 5, (24.4) SHC 5,400 5,50 4,790 4,790 0,750 7,940 (2.7) 80 (26.7) SHC 7,840 7,600 7,360 7,230 3,200 0, (28.9) SHC 20,70 9,920 9,680 9,560 5,520 2,70 88 (3.) SHC 22,490 22,250 22,000 2,880 7,840 5,030 TC 36,560 36,070 35,450 34,630 24,680 6,830 CI (24.4) SHC,850,60,360,20 7,570 5,30 (23.9) 80 (26.7) SHC 4,300 4,050 3,80 3,560 0,020 7, (28.9) SHC 6,620 6,500 6,250 5,890 2,340 9, (3.) SHC 8,940 8,820 8,580 8,20 4,660 2,220 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 F (26.7 C) DB / 67 F (9.4 C) WB : Outdoor Ambient Temp. 95 F (35 C) DB 2. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 3. Above data represents the value when the operation frequency of a compressor is fixed. 22

23 5-3. Cooling Capacity (Low Ambient) Indoor Unit : Outdoor Unit : Power supply : CS-KS30NKU CU-KS30NKUA 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: 30,600 BTU/h AIR FLOW RATE: 630 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) WB DB (-7.8) (-5.0) (-9.4) (-3.9) (.7) (7.2) (2.8) TC 30,20 30,060 29,930 29,780 29,590 29,330 29,070 CI (22.2) SHC 2,50 2,50 2,020 23,230 20,780 20,660 20, (24.4) SHC 23,470 23,470 23,350 25,550 23,230 22,980 22,860 (5.0) 80 (26.7) SHC 25,920 25,920 25,790 27,870 25,670 25,430 25, (28.9) SHC 28,240 28,240 28,20 29,780 27,990 27,870 27, (3.) SHC 30,20 30,060 29,930 29,780 29,590 29,330 29,070 TC 30,390 30,360 30,270 30,70 30,040 29,820 29,60 CI (22.2) SHC 7,720 7,720 7,600 23,230 7,480 7,360 7, (24.4) SHC 20,050 20,050 9,920 25,550 9,800 9,800 9,680 (7.2) 80 (26.7) SHC 22,490 22,490 22,370 27,870 22,370 22,250 22,20 84 (28.9) SHC 24,820 24,820 24,820 30,70 24,690 24,570 24, (3.) SHC 27,40 27,40 27,40 30,70 27,020 26,890 26,770 TC 30,490 30,480 30,450 30,400 30,330 30,60 30,020 CI (22.2) SHC 4,80 4,80 4,80 23,230 4,80 4,050 4, (24.4) SHC 6,500 6,500 6,500 25,550 6,500 6,380 6,380 (9.4) 80 (26.7) SHC 9,070 8,940 8,940 27,870 8,940 8,820 8, (28.9) SHC 2,390 2,390 2,390 30,200 2,270 2,50 2,50 88 (3.) SHC 23,70 23,70 23,70 30,400 23,590 23,590 23,470 TC 30,370 30,380 30,40 30,430 30,420 30,30 30,250 CI (22.2) SHC 0,50 0,50 0,50 23,230 0,630 0,50 0, (24.4) SHC 2,950 2,950 2,950 25,550 2,950 2,830 2,830 (2.7) 80 (26.7) SHC 5,400 5,400 5,400 27,870 5,400 5,280 5, (28.9) SHC 7,720 7,720 7,720 30,200 7,720 7,720 7, (3.) SHC 20,050 20,050 20,050 30,430 20,050 20,050 20,050 TC 30,030 30,080 30,70 30,240 30,30 30,250 30,270 CI (24.4) SHC 9,40 9,40 9,40 25,550 9,530 9,530 9,530 (23.9) 80 (26.7) SHC,850,850,850 27,870,970,970, (28.9) SHC 4,80 4,80 4,300 30,200 4,300 4,300 4, (3.) SHC 6,500 6,620 6,620 30,240 6,620 6,620 6,620 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE. Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 2. Above data represents the value when the operation frequency of a compressor is fixed. 23

24 Indoor Unit : Outdoor Unit : Power supply : CS-KS36NKU CU-KS36NKUA 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > - RATING CAPACITY: 34,000 BTU/h AIR FLOW RATE: 630 CFM INDOOR OUTDOOR ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o C) WB DB (-7.8) (-5.0) (-9.4) (-3.9) (.7) (7.2) (2.8) TC 30,900 30,870 30,800 30,70 30,590 30,400 30,20 CI (22.2) SHC 2,50 2,50 2,50 23,230 2,390 2,270 2, (24.4) SHC 23,960 23,840 23,840 25,550 23,70 23,590 23,470 (5.0) 80 (26.7) SHC 26,400 26,400 26,280 27,870 26,60 26,040 25, (28.9) SHC 28,730 28,730 28,60 30,200 28,480 28,480 28, (3.) SHC 30,900 30,870 30,800 30,70 30,590 30,400 30,20 TC 3,00 3,00 30,990 30,950 30,890 30,750 30,620 CI (22.2) SHC 7,970 7,970 7,970 23,230 7,970 7,840 7, (24.4) SHC 20,40 20,40 20,290 25,550 20,290 20,70 20,70 (7.2) 80 (26.7) SHC 22,860 22,860 22,740 27,870 22,740 22,60 22,60 84 (28.9) SHC 25,80 25,80 25,80 30,200 25,060 25,060 24, (3.) SHC 27,50 27,50 27,50 30,950 27,380 27,380 27,260 TC 30,90 30,940 30,980 3,000 3,00 30,930 30,880 CI (22.2) SHC 4,420 4,420 4,420 23,230 4,420 4,420 4, (24.4) SHC 6,740 6,740 6,740 25,550 6,740 6,740 6,740 (9.4) 80 (26.7) SHC 9,90 9,90 9,90 27,870 9,90 9,90 9,90 84 (28.9) SHC 2,50 2,50 2,640 30,200 2,640 2,50 2,50 88 (3.) SHC 23,840 23,960 23,960 3,000 23,960 23,960 23,840 TC 30,570 30,620 30,730 30,820 30,90 30,900 30,930 CI (22.2) SHC 0,630 0,630 0,750 23,230 0,750 0,750 0, (24.4) SHC 2,950 2,950 3,070 25,550 3,070 3,070 3,070 (2.7) 80 (26.7) SHC 5,400 5,400 5,520 27,870 5,520 5,520 5, (28.9) SHC 7,720 7,840 7,840 30,200 7,970 7,970 7, (3.) SHC 20,70 20,70 20,70 30,820 20,290 20,290 20,290 TC 30,00 30,090 30,260 30,430 30,590 30,650 30,770 CI (24.4) SHC 9,40 9,40 9,530 25,550 9,650 9,650 9,650 (23.9) 80 (26.7) SHC,850,850,970 27,870 2,00 2,00 2,00 84 (28.9) SHC 4,80 4,80 4,300 30,200 4,420 4,420 4, (3.) SHC 6,500 6,620 6,620 30,430 6,740 6,740 6,870 TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) CI : Compressor Input (kw) NOTE Above data does not take freeze prevention protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 2 Above data represents the value when the operation frequency of a compressor is fixed. 24

25 5-4. Air Throw Distance Charts Indoor Unit CS-KS30NKU Cooling Room air temp. : 80 F (26.7 C) Fan speed : High Horizontal distance (ft.) Axis air velocity (ft./sec.) Vertical distance (ft.) : Flap angle 0, : Axis air velocity 0 : Flap angle 30, : Axis air velocity 30 25

26 Indoor Unit CS-KS36NKU Cooling Room air temp. : 80 F (26.7 C) Fan speed : High Horizontal distance (ft.) Axis air velocity (ft./sec.) Vertical distance (ft.) : Flap angle 0, : Axis air velocity 0 : Flap angle 30, : Axis air velocity 30 26

27 6. ELECTRICAL DATA 6-. Electrical Characteristics Indoor Unit CS-KS30NKU Outdoor Unit CU-KS30NKUA () Voltage:230V Cooling Indoor Fan Motor Performance at Rating conditions Running amp. A 0.4 Power input W 39 UnitOutdoor Unit Fan Motor + Compressor 230V Single-phase 60Hz 6. 3,25 < 230V > Complete Unit 6.5 3,290 Rating conditions: Indoor air temperature: 80 F (26.7 C) DB / 67 F (9.4 C) WB Outdoor air temperature: 95 F (35 C) DB (2) Voltage:208V Cooling Indoor Fan Motor Performance at Rating conditions Running amp. Power input A W Rating conditions: Indoor air temperature: 80 F (26.7 C) DB / 67 F (9.4 C) WB Outdoor air temperature: 95 F (35 C) DB UnitOutdoor Unit Fan Motor + Compressor 208V Single-phase 60Hz 7.6 3,25 < 208V > Complete Unit 8.0 3,290 27

28 Indoor Unit CS-KS36NKU Outdoor Unit CU-KS36NKUA () Voltage:230V Cooling Indoor Fan Motor Performance at Rating conditions Running amp. A 0.4 Power input W 39 UnitOutdoor Unit Fan Motor + Compressor 230V Single-phase 60Hz 9.6 3,96 < 230V > Complete Unit ,000 Rating conditions: Indoor air temperature: 80 F (26.7 C) DB / 67 F (9.4 C) WB Outdoor air temperature: 95 F (35 C) DB (2) Voltage:208V Cooling Indoor Fan Motor Performance at Rating conditions Running amp. Power input A W Rating conditions: Indoor air temperature: 80 F (26.7 C) DB / 67 F (9.4 C) WB Outdoor air temperature: 95 F (35 C) DB UnitOutdoor Unit Fan Motor + Compressor 208V Single-phase 60Hz 2.5 3,96 < 208V > Complete Unit 2.9 4,000 28

29 6-2. Electric Wiring Diagrams Indoor Unit CS-KS30NKU CS-KS36NKU EVAPORATOR M FLAP MOTOR PL ELEC J-B GRN/YEL RED ORG YEL PNK BLU GRN GND FLAP 5P (WHT) GND 2P (WHT) + + AC IN COM + BLK WHT RED SI LAMP 9P (WHT) CONTROLLER TERMINAL BASE 2 3 U U2 GND WHT BLK BLK BLK BLK BLK BLK BLK BLK TO OUTDOOR UNIT IND LAMP ASSY OPERATION SW M FAN MOTOR RED BLK WHT YEL BLU DCM 7P (WHT) S-LINK (RAC) 4P (BLU) T0 6P (BLU) COIL 2P (WHT) ROOM/UV 4P (WHT) BLK BLK BLK BLK COIL THERMISTOR ROOM THERMISTOR 8FA

30 Outdoor Unit CU-KS30NKUA CU-KS36NKUA 8FA CONTROL P.C.BOARD NOISE FILTER P.C. BOARD HIC BOARD + + HIC- W T S R V U HIC+ + L + L2 + DC- TH0 (YEL) TH + + M 3 COMPRESSOR MOTOR BLU WHT RED HIC (WHT) CN0 (WHT) WHT BLK BLK BLK BLK BLK BLK BLK BLK BLK HIC2 (WHT) CN02 (WHT) BLK BLK BLK BLK BLK BLK BLK BLK (WHT) MV (WHT) TEST/MV MAGNETIC COIL HEAT SINK (RADIATOR) BRIDGE DIODE ORG RED YEL BLK GRY 2 2 (BLK) COIL YEL YEL COIL THERMISTOR 2 2 (GRN) PRY BLK WHT (WHT) DCOUT BLK WHT (ORG) ACOUT BLK WHT (BRN) (GRN) (WHT) (ORG) (BRN) CT PRY DCIN ACIN CT WHT WHT 2 2 INDOOR UNIT POWER SUPPLY GND TERMINAL (5P) FM2 (RED) RED BLU BRN WHT ORG FM (RED) FAN MOTOR REACTOR C w E2 w E YEL YEL BLU w CH2 CRANKCASE HEATER WHT WHT WHT DC+ YEL GRY YEL + + AC2 w AC IN2 w AC IN WHT + + AC BLK M M 2 2 (WHT) COMP BLK BLK COMPRESSOR THERMISTOR 2 2 (YEL) OUTDOOR BLK BLK OUTDOOR THERMISTOR GRN/YEL 2 2 (BLK) HP-SW RED RED HIGH PRESSURE SW 2 2 (RED) OLR WHT WHT OVER LOAD RELAY BLK WHT + L3 + L4 BLK WHT + C + C2 + HIC+ + HIC- BLK WHT w w CH SI w S-COM WHT BLK WHT RED WHT BLK WHT GRN GRN 30

31 7. FUNCTIONS 7-. Operation Functions Emergency operation Emergency operation is available when the remote controller malfunctions, has been lost, or otherwise cannot be used. To operate the system, press the OPERATION button, which is also used as the receiver, below the unit display. Each time this button is pressed, the OPERATION lamp changes color to indicate the type of operation. Select the desired type of operation. SENSOR DRY During DRY operation, the system adjusts the room temperature and fan speed according to the conditions in the room, in order to maintain a comfortable room environment. SENSOR DRY operation DRY operation is as shown in the figure below. Load COOL (GREEN) STOP (Lamp Off) COOL zone A zone The set temperature is 4 F(2 C) below the detected room temperature in the case of cooling operation. B zone Conditions are monitored at all times when the room temperature is below 59 F(5 C). DRY A The compressor operation frequency varies. The indoor fan operates with /f fluctuation. DRY B The compressor operates at a low operating frequency. The indoor fan operates with /f fluctuation. Monitor Monitoring operation takes place when the room temperature is below 59 F(5 C), or more than 5 F(3 C) below the set temperature. When the monitoring range is entered, the compressor stops, and the indoor fan operates with /f fluctuation. NOTE The Sensor Dry operation during the Low Ambient Cooling Mode (outside air temperature : 59 F(5 C) or lower) is as follows. DRY A and DRY B When room temperature rises above the set temperature, the compressor turns ON. When room temperature falls below the set temperature, the compressor turns OFF. 3

32 HIGH POWER This function acts to raise the power but keeps the AC system in the same operating mode. This function is set with the HIGH POWER button on the remote controller. (It can be set regardless of the temperature and fan speed settings.) HIGH POWER operation from remote controller The unit operates at maximum output for 30 minutes, regardless of the desired temperature. The fan speed is step above "High." Frequency MAX NIGHT SETBACK When NIGHT SETBACK operation is set, the temperature and fan speed settings will be adjusted automatically to allow comfortable sleep. When NIGHT SETBACK operation is set, " mark" appears on the remote controller. The main unit display lamp also becomes dimmer. COOL and DRY modes When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 F( C) when 30 minutes have passed after the selection was made, and then another 2 F( C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed min. 5 min. Time Setting temperature 2 F( C) 2 F( C) NOTE Start End When HIGH POWER operation ends, the unit operates at low Hz for 5 minutes, regardless of the thermostat OFF conditions. When in DRY mode, operation is in the cooling zone. Press the NIGHT SETBACK button 30 min. 30 min. Time Lamp colors OPERATION lamp DRY operation COOL operation FAN operation TIMER lamp Orange Green Green Green Timer backup Operation stops if there are no operator controls for 25 hours or longer after unit operation switched from OFF to ON by use of ON timer operation. 32

33 Noise Reducing Control (Outdoor Unit) The noise reducing control is the function used for silent operation of the air conditioner by means of setting the dip switch on the outdoor unit P.C.Board to control the fan and compressor's motor speed. NOTE When this function is used, the cooling ability is slightly degraded. Therefore, when this function is to be enabled, make sure to receive the approval of the client. <Operation Sound> Noise Reducing Control Specifications (Fan's motor speed : 500rpm) Cooling Cooling 55 db-a 47 db-a Outdoor Air Temp. F( C) <In Cooling Operation> Normal Operation 9(33) 82(28) Normal Operation or Noise Reducing Operation is kept. (Initial setting is the normal operation.) Noise Reducing Operation NOTE. In the test operation, high-power operation, defrost operation or low ambient cooling operation (to be cancelled at the outside temperature of 57 F(4 C) or less, or 63 F(7 C) or more), the noise reducing control is not available. 2. In the noise reducing operation, the fan's maximum motor speed is limited to 500rpm. Also, the maximum frequency (Hz) is controlled in the cooling (30Hz) or heating operation (30Hz). <Switching Procedure to Noise Reducing Control> () Remove the 3 screws fixing the inspection panel and remove the inspection panel. (Fig. 2) (2) When the switch No. of the dip switch (SW0) on the control P.C.Board is turned ON, the noise reducing control is enabled. (Fig. 3) Power lamp Control P.C.Board ON Inspection panel 2 Dip switch (SW0) Slide downward SW0 Fig.3 Control P.C.Board Fig.2 View from front 33

34 Maximum Current Value Change Function The maximum current value is changed to 4A (for CU-KS30NKUA) or 7A (for CU-KS36NKUA) to prevent power breaker tripping. (It is set to 24A when the unit is delivered from the factory.) NOTE. When the high load is given (Outside temperature is high in the cooling operation), the capacity is reduced. When the maximum current value change function is to be enabled, make sure to receive the approval of the client. 2. The maximum capacity for cooling operation is about as much as the rated capacity. Description of function Frequency Current Target frequency Example of operation Frequency Stops operation Approx.3 minutes Power Point C Point B Point A Operates at the target frequency at Point A and below. Stops increases to the frequency between Points A and B. Reduces the frequency by Hz per 0.5 seconds when Point B is exceeded. Stops operation, and restarts it appoximately 5 minutes later, if Point C is exceeded. (May operate when sudden voltage fluctuations occur. Indicates trouble.) < CU-KS30NKUA > Current Value on the Point C Current Value on the Point B Current Value on the Point A < CU-KS36NKUA > Current Value on the Point C Current Value on the Point B Current Value on the Point A In cooling operation (25.0) In cooling operation (25.0) <Maximum Current Value Change Procedure> () Remove the inspection panel. Refer to Fig. 2 in " Noise Reducing Control" for details. (2) When the switch No.2 of the dip switch (SW0) on the control P.C.Board is turned ON, the maximum current value change. (Fig. 4) Power lamp Dip Switch (SW0) Switch No.2 ON OFF Max. Current Value CU-KS30NKUA CU-KS36NKUA 4.0A 7.0A 22.0A 24.0A ON 2 Dip switch (SW0) SW0 Fig.4 Control P.C.Board 34

35 7-2. Protective Functions Freeze prevention During COOL or DRY operation, freezing is detected and operation is stopped when the temperature of the indoor heat exchanger matches the conditions below.. Freeze-prevention operation is engaged when the temperature of the indoor heat exchanger is below 4 F(5 C). 2. Restart after freeze-prevention operation occurs when the temperature of the indoor heat exchanger reaches 46 F(8 C) or above. Indoor heat exchanger temperature F( C) 46 (8) 4 (5) 36 (2) * A a b c d a. Area: Automatic capacity control b. When the temperature drops below Point A, the operation frequency is reduced by a certain proportion. c. Area: Frequency increase is prohibited. d. When the temperature reaches Point C or above, freezing prevention is ended and control is the same as in the a area. * When the temperature drops to below 36 F(2 C) (continuously for 2 minutes or longer), the compressor stops. Once the freeze condition is detected, the air conditioner will work less than the maximum frequency until it is turned off. B C Compressor discharge temperature control This function controls the operation frequency to prevent the compressor discharge temperature from rising more than a specified temperature. Compressor discharge temperature F( C) Approx. 24 (0) Approx. 20 (94) A a b c d a. Area: Automatic capacity control. b. When the temperature rises above Point A, the operation frequency is reduced at a specified rate. c. Area: Further frequency increase is prohibited. d. When the temperature falls below Point B, prevention of a rise in frequency is released and the air conditioner operates as in a area. * The compressor will stop if the temperature of the compressor discharge exceeds 248 F(20 C) due to shortage of gas or other reason. CT (Peak current cut-off control) This function prevents the circuit breaker or fuse from operating to open the circuit. This function works when electrical current has increased due to an increase in the cooling load, or to a decrease in the power supply voltage. In these cases, operation frequency is reduced or operation is interrupted automatically to control the electrical current for operation. When the cause of the increase in electrical current is rectified, the system will resume operation in the original mode. < CS-KS30NKU > (A) Cooling Dry Peak current cut-off trips 25.0 Hz down 22.0 B < CS-KS36NKU> Cooling Dry Peak current cut-off trips 25.0 Hz down 24.0 (A) 35

36 8. TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) 8-. Precautions before Performing Inspection or Repair After checking the self-diagnostics monitor, turn the power OFF before starting inspection or repair. High-capacity electrolytic capacitors are used inside the outdoor unit controller (inverter). They retain an electrical charge (charging voltage DC 30V) even after the power is turned OFF, and some time is required for the charge to dissipate. Be careful not to touch any electrified parts before the controller LED (red) turns OFF. If the outdoor controller is normal, approximately 30 seconds will be required for the charge to dissipate. However, allow at least 5 minutes for the charge to dissipate if there is thought to be any trouble with the outdoor controller Method of Self-Diagnostics Follow the procedure below to perform detailed trouble diagnostics. NOTE < Clock display > Test run mode Deletion of self-diagnostics report mode Self-diagnostics mode : If the operation lamp blinks every 0.5 seconds immediately when the power is turned ON, there is an external ROM (OTP data) failure on the indoor circuit board, or a ROM socket insertion problem, or the ROM has not been installed. 2: The failure mode is stored in memory even when the power is not ON. Follow the procedure below to perform diagnostics. PROCEDURE After turning on power to the air conditioner, use the remote controller and follow the steps below to execute self-diagnostics. Step : Press and hold the remote controller QUIET button and HR TIMER button. Then, press and hold the ACL (reset) button with a pointed object such as the tip of a pen. After 5 seconds, release ACL button first, then release QUIET and HR TIMER buttons, "op-" (test run) appears, blinking in the remote controller clock display area. Step 2: Next, press the HR TIMER button twice to change the display from "op-" to "op-2" and "op-3" (self-diagnostics). (The display continues to blink.) Step 3: Finally press the ON/OFF button to engage self-diagnostics mode. The self-diagnostics function utilizes the 3 indicator lamps on the main unit, in combinations of ON lamps, blinking lamps, and OFF lamps, to report the existence of sensor trouble or a protective operation. (The lamps blink or remain ON for 5 seconds, then turn OFF for 2 seconds.) Self-diagnostics is completed when the buzzer sounds 3 short beeps. A maximum of 3 self-diagnostics reports are displayed, for 5 seconds each, beginning with the most recent report. Following this display the lamps turn OFF. In order to view the self-diagnostics results again, press the ON/OFF button again. The 3 lamps remain OFF if no trouble has occurred. <IMPORTANT> After self-diagnostics is completed, be sure to press the ACL (reset) button to return to normal mode. The air conditioner will not operate if this is not done. QUIET button ON/OFF operation button HR. TIMER button ACL (Reset) button 36

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS0971 + C0971 + CL0971 KS1271 + C1271 + CL1271 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS0971 KS1271 Product

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL MCAF88R5I + GRF86R5I MCAF48R5I + GRF46R5I FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. MCAF88R5I MCAF88R5IAA

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : KMS0772 FILE NO. KMS0972 KMS1272 KMS1872 KMS2472 Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL MCAF94R5IAA + GRF97R5I MCAF124R5IAA + GRF127R5I FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. MCAF94R5IAA

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : MCAF78MR5I MCAF98MR5I MCAF128MR5I MCAF188R5I MCAF248R5I FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : MPAF90MRI MPAF0MRI MPAF80RI MPAF0RI DC INVERTER MULTISYSTEM AIR CONDITIONER Capacity Indoor Model No..6 kw.0 kw. kw 7.0 kw MPAF90MRI MPAF0MRI MPAF80RI MPAF0RI Wall

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : SAP-CMRVEH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 0.0kW Outdoor Model No. SAP-CMRVEH-F Product Code No. 8 8 SAP-CMRVEH

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL TECHNICAL & SERVICE MANUAL INDOOR UNIT: MCAF94MR5IAA MCAF124MR5IAA MCAF184MR5IAA MCAF244MR5IAA NOV.2003 Destination: General area (50Hz) Europe (50Hz) Australia (50Hz) General area (60Hz) DC INVERTER MULTI-SYSTEM

More information

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A TECHNICAL & SERVICE MANUAL SAP K181A SAP K241A + SAP C181A + SAP C241A FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K181A S 1 852 068 06 SAP K241A

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: ASR609CL ASR612CL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. ASR609CL 387006970 ASR612CL 387006971 0.8180.250.0 05/2002 IMPORTANT! Please read

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE726SCL AE752SCL AE71SCL3 AE735SCL AE752SCL3 AE100SCL3 AE764SCL3 AE125SCL3 SPLIT SYSTEM AIR CONDITIONER Model No. AE726SCL AE735SCL AE752SCL AE752SCL3 AE764SCL3

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT:. TRIAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.102. 0.8180.611.02 09/2012 IMPORTANT! Please read before installation This air conditioning

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL AWR222CLE - AER222SC AWR222CLE - AER222SC3 SPLIT SYSTEM AIR CONDITIONER 0.8180.076.0 03/00 Important! Please Read Before Starting This air conditioning system meets strict safety

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA

More information

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL HEAT PUMP MODELS INDOOR UNIT: MPAF188R5TAA MPAF228R5TAA COOLING MODELS MPAF188C5TAA MPAF228C5TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MPAF188R5TAA 38.7104.033

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF94R5 CAF124R5 SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. CAF94R5 387106979 CAF124R5 387106980 0.8180.361.0 07/2005 IMPORTANT! Please read before

More information

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH

More information

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to

More information

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.

More information

SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MRAF99R5IAA MRAF129R5IAA MPAF99R5IAA MPAF129R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MRAF99R5IAA 38.7104.065 MRAF129R5IAA 38.7104.062 MPAF99R5IAA

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications

More information

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO. TECHNICAL & SERVICE MANUAL SAP K301AH + SAP C301AH FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K301AH S 1 852 071 34 Outdoor Model No. Product Code

More information

INVERTER SPLIT SYSTEM AIR CONDITIONER

INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP-KRV91EH + SAP-CRV91EH FILE NO. INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. Destination SAP-KRV91EH 1 852 065

More information

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER TECHNICAL DATA & SERVICE MANUAL Outdoor Unit GR54M2C Indoor Unit MCA27MC (X2) MULTI-SPLIT SYSTEM AIR CONDITIONER Indoor Unit Outdoor Unit MCA27MC GR54M2C 0.8180.195.0 04/2001 IMPORTANT! Please Read Before

More information

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B

More information

7-5. Remove the Grille to Install the Indoor Unit

7-5. Remove the Grille to Install the Indoor Unit 7-5. Remove the Grille to Install the Indoor Unit Basically, these models can be installed and wired without removing the grille. If access to any internal part is needed, follow the steps as given below.

More information

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW22AL 387030005 AW28AL 387030006 AW38AL 387030007 AW42AL 387030094 0.8180.467.0

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA- TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA- SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MCAF72R5TA- 387104015 MCAF92R5TA- 387104016 MCAF122R5TA- 387104017

More information

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1 SERVICE MANUAL Inverter Wall Mounted Single Split MODELS Cooling Only FTKB09AXVJU FTKB12AXVJU FTKB18AXVJU FTKB24AXVJU FTKN09AXVJU FTKN12AXVJU FTKN18AXVJU FTKN24AXVJU Heatpump FTXB09AXVJU FTXB12AXVJU FTXB18AXVJU

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K303A + SAP C303A FILE NO. Destination: Australia SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. SAP K303A A 1 852 098 83 Outdoor Model No.

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product

More information

MULTI-SPLIT SYSTEM AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP KM97AHA ( 2) + SAP CM1827AHA FILE NO. Destination: Australia MULTI-SPLIT SYSTEM AIR CDITIER Indoor Model No Product Code No. Outdoor Model No. Product Code No. SAP KM97AHA

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F. Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AE22AH 387031006 AE28AH 387031007 AE38AH 387031008

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2 Order No: MAC008C Room Air Conditioner CS-E9BKP CU-E9BKP5 CS-EBKP CU-EBKP5 CONTENTS Page Page Features Functions Product Specifications 6 Dimensions 0 5 Refrigeration Cycle Diagram 6 Block Diagram 7 Wiring

More information

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA

TECHNICAL & SERVICE MANUAL WIRED REMOTE CONTROLLER STK-RCS-7TWSUA FILE NO. Product Code No Model No. STK-RCS-7TWSUA TECHNICAL & SERVICE MANUAL STK-RCS-7TWSUA FILE NO. Destination: North America WIRED REMOTE CONTROLLER Model No. STK-RCS-7TWSUA Product Code No. 1 852 353 85 REFERENCE NO. SM700799 Important! Please Read

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245SCH2O( I ) Cooling only model ARGO 235HPH2O( I ) Heat pump model 0.8180.519.1 11 / 2007 Table of contents Page A SPECIFICATIONS 1) Unit specifications

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS*G09LTCB AS*GLTCB AS*G4LTCB AO*G09LTCN AO*GLTCN AO*G4LTCN R40A CONTENTS. DESCRIPTION OF EACH

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU9RLS ASURLS ASU5RLS AOU9RLSH AOURLSH AOU5RLSH R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: DUAL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. 38.7107.098 38.7107.103 38.7107.106 0.8180.597.03 09/2012 IMPORTANT! Please read before installation

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G09LMCA AO G12LMCA AO G14LMCA 1. INDOOR UNIT : AS G07LMCA AS G09LMCA

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL XH7R / CH7R, C7R XH7R / CH7R, C7R XH7R / CH7R, C7R TH7R / CH7R, C7R TH7R / CH7R, C7R TH7R / CH7R, C7R THH7R / CH7R THH7R / CH7R FILE NO. KH7R / CH7R, C7R KH07R / CH07R,

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02

More information

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1 Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Using the Remote Control Unit

Using the Remote Control Unit Remote Control Unit (continued) SENSOR button Temperature Display Selector button Time Display Selector button ACL button (ALL CLEAR) When you press this button (use a small-tipped object such as a ballpoint

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE

More information

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models

SERVICE MANUAL MSC-A07YV - (WH) MSC-A09YV - (WH) MSC-A12YV - (WH) HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MSC-A07YV - (WH) E MSC-A09YV - (WH) E MSC-AYV - (WH) HFC utilized R40A. OB39 CONTENTS Indication

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

C&H NORDIC Commercial 4 SERVICE MANUAL

C&H NORDIC Commercial 4 SERVICE MANUAL C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...

More information

Fast Track Troubleshooting

Fast Track Troubleshooting Fast Track Troubleshooting Models Covered: RF266AD**/XAA French Door Refrigeration IMPORTANT SAFETY NOTICE For Technicians Only This service data sheet is intended for use by persons having electrical,

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

SERVICE MANUAL. Wall Mounted Type ON/OFF T-Series HSU-07HUN103/R2-P WARNING. Haier Group Version V1 Date

SERVICE MANUAL. Wall Mounted Type ON/OFF T-Series HSU-07HUN103/R2-P WARNING. Haier Group Version V1 Date SERVICE MANUAL Wall Mounted Type ON/OFF T-Series Model No.1U07OR4EAA HSU-07HUN103/R2-P WARNING This service information is designed for experienced repair technicians only and is not designed for use by

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC Revision G: Errors in TROUBLESHOOTING have been corrected. Please void OB455 REVISED EDITION-F. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB455 REVISED EDITION-G Models MUZ-GB50VA - E1 MUZ-GB50VA

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information