HORIZONTAL LOW PROFILE FAN COIL IN ROOM HORIZONTAL LOW PROFILE FAN COIL UNITS IN ROOM

Size: px
Start display at page:

Download "HORIZONTAL LOW PROFILE FAN COIL IN ROOM HORIZONTAL LOW PROFILE FAN COIL UNITS IN ROOM"

Transcription

1 HORIZONTAL LOW PROFILE FAN OIL IN ROOM HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM

2 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Low Profile, Blow-through Design Sloped drain pan Galvanized or Stainless Steel 8 gauge galvanized steel casing Blower/Motor assembly; isolated from fan housing -speed EM or PS Motor(s) Electric heat Hanger Brackets (Typ. 4) /8" () Dia. Filter " (25) throwaway MERV 8 pleated Hinged door controls enclosure HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Multiple coil options up to 6 rows Louvered Return Grille 8 gauge galvanized steel casing with appliance white coated finish 4HT - Telecoping Telescoping return air grille Optional secondary drain outlet Primary drain outlet 4HF - Free Return 4HX - Exposed 4HP - with Plenum 2

3 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Low Profile Horizontal Fan oil Units The Engineered omfort Low Profile 4H Series fan coil units are designed for hotels, schools, apartments and residential condominiums which occupy a minimum of space and minimize field installation time and cost. The Low Profile Horizontal Fan oil Units 4H Series provides the following benefits: Airflow capacities from 5 FM ( 78 l/s). ompact blow through design. -speed EM or PS motor(s). Single point electrical connections. Blower/motor assembly isolated from fan housing with vibration isolators. AHRI certified units available as: 2-pipe system: Type W: or 2 row coil for heating only. Type Z: or 4 row coil for cooling or heating. 4-pipe system: Type ZW: or 4 row cooling coil and or 2 row heating coil (Either as reheat or preheat). Standard and Features ONSTRUTION ETL Listed. onstructed in compliance with ANSI/ UL Standard. 8 gauge galvanized steel casing. " (25) Throwaway filter. /2" () dual density insulation, exposed edges coated to prevent air erosion. Meets the requirements of NFPA 9A and UL 8. Single point electrical connection. Discharge collar for duct connection. Standard controls enclosure is mounted on side opposite coil connections. FAN/MOTOR ASSEMBLIES Forward urved, DWDI, direct driven blowers. Blower/motor assembly isolated from fan housing with vibration isolators. Motor power leads with quick disconnect brought into an external hinged door starter-control enclosure. Energy efficient -speed PS fan motor(s) with thermal overload protection. 2, 28, 24 and 277 volt single phase motor. OILS /2" (2.7) copper tubes with aluminum ripple fins. ooling coils include a foam insulated, galvanized steel sloped drain pan with 7/8" (22.2) O.D. primary drain connection. Field reversible. Left hand coil unit/connection (looking in direction of airflow) is standard. Right hand is opposite. Manual air vent(s). Sweat onnections: All 5/8" (5.9) O.D. male solder except size 5 three and four row: 7/8" (22.2) O.D. male solder. DRAIN PANS Positively sloped galvanized steel drain pan. Externally insulated with fiber-free foam. PAINTED FINISH All painted cabinet exterior panels shall be finished with a durable and aesthetically attractive Appliance White Powder oated finish. Options and Accessories ONSTRUTION Ultra-energy efficient -Speed EM Motor(s) with thermal overload protection. Outside air Inlet (4HP). " (25) Throwaway filter with spare. " (25) MERV 8. " (25) MERV 8 with spare. OILS Automatic air vent(s). oil asing 2 ga. (.) stainless steel drain pan externally insulated with fiber-free foam. Stainless steel coil casing. Increased tube wall thickness.25" (.65). DRAIN PANS Galvanized with secondary drain pan connection. Stainless steel drain pan. Stainless steel drain pan with secondary connection. INSULATION /2" () Dual density fiberglass liner. /2" () Foil face fiberglass liner. losed cell foam liner. ONTROL PAKAGES Toggle disconnect switch. Door interlocking disconnect switch. Main unit fusing. Drain pan float switch (24V). 24V transformer and fan relay packages. Factory installed controls provided by others. VALVE-PIPING PAKAGES Shipped loose on the models 4HT, 4HP and 4HF for field installation. Factory assembled and installed in an enclosure or shipped loose on model 4HX for field installation. /2" or /4" ( or 9) 2 or way valves. On/Off, 24V, modulating vdc. Ball valves, Unions, P/T ports and Shut-off valves. Strainers and Strainer with hose bib valve. P/T ports and Bypass balancing valve. OTHER OPTIONS LH or RH control/coil connection. Dust tight controls enclosure. ondensate pump. Auxiliary drip pan, galvanized or stainless steel. PAINTED FINISH All painted cabinet exterior panels shall be finished with an optional Wood Grain Finishes in order to complement the architectural décor. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM

4 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Free Return 2 or 4 Pipe ooling/heating Model 4HF Unit Sizes 5 TYPE Z TYPE ZW hilled/hot Water (2-pipe). hilled & Hot Water (4-pipe). 6" (52) 2" (5) FLEXIBLE ONDUIT D (HANGER HOLES) HANGER BRAKETS (TYP. 4) /8" () DIA. 5 /2" (4) 7 /4" (84) DRAIN PAN OUTLET HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 6 /4" (7) /2" (8) "J" BOX 4 x 4 "J" BOX (LINE VOLTAGE ONTROL ONLY) OR ONTROLS ENLOSURE AS REQUIRED (FIELD REMOTE MOUNTABLE) Dimensional Data Unit Size Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN A B D () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 4 /4" (2) 2" (55) MAX. OPTIONAL AUX. DRIP PAN HILLED / HOT WATER SUPPLY RETURN ONNETIONS " (25) /2" () 6 5/8" " (68) (254) OPTIONAL SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET 24 7/8" (62) 7" (42) FAN OPTIONAL BOTTOM MOUNT ONTROLS ENLOSURE WITH HINGED DOOR 9" (229) LEARANE REQUIRED 4

5 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Free Return 2 Pipe ooling/heating & Electric Heat Model: 4HF Unit Sizes 5 TYPE ZE hilled/hot Water (2-pipe) and Electric Heat D (HANGER HOLES) 7 /4" (84) HANGER BRAKETS (TYP. 4) /8" () DIA. /2" (8) Dimensional Data Unit Size Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN A B D 5" (27) 2" (55) MAX. OPTIONAL AUX. DRIP PAN () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) DRAIN PAN OUTLET HILLED / HOT WATER SUPPLY RETURN ONNETIONS " (25) 24 7/8" (62) /2" 7" (42) () 6 5/8" " (68) (254) OPTIONAL SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET ELETRI HEAT FAN HINGED DOOR ONTROLS ENLOSURE 9" (229) LEARANE REQUIRED HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 5

6 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H With Plenum 2 or 4 Pipe ooling/heating Model: 4HP Unit Sizes 5 TYPE Z TYPE ZW hilled/hot Water (2-pipe). hilled & Hot Water (4-pipe). D (HANGER HOLES) - 2" (5) HANGER BRAKETS (TYP. 4) /8" () DIA. 5 /2" (4) 6" (52) 2" (5) 7 /4" (48) DRAIN PAN OUTLET HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 6 /4" (7) /2" (8) "J" BOX 4 x 4 "J" BOX (LINE VOLTAGE ONLY) OR ONTROLS ENLOSURE AS REQUIRED (FIELD REMOTE MOUNTABLE) Dimensional Data Unit Size Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN 4 /4" (2) 2" (55) MAX. OPTIONAL AUX. DRIP PAN A B D HILLED / HOT WATER SUPPLY RETURN ONNETIONS 6 5/8" (68) /2" () OPTIONAL SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET Filter Size Width x Height () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 2 x (58 x 254) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 25 x (65 x 254) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) x (762 x 254) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2@ 2 x (58 x 254) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 2@ 25 x (65 x 254) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 2@ x (762 x 254) " (25) 28" (7) " (25) THROWAWAY FILTER FAN 2 /8" (54) RETURN AIR " (254) OPTIONAL OPTIONAL BOTTOM BOTTOM RETURN MOUNT ONTROLS ENLOSURE, 9" (229) LEARANE REQUIRED 6

7 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H With Plenum 2 Pipe ooling/heating & Electric Heat Model: 4HP Unit Sizes 5 TYPE ZE hilled Water and Electric Heat D (HANGER HOLES) - 2" (5) HANGER BRAKETS (TYP. 4) /8" () DIA. 7 /4" (48) /2" (8) Dimensional Data Unit Size Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN 4 /4" (2) 2" (55) MAX. OPTIONAL AUX. DRIP PAN A B D DRAIN PAN OUTLET HILLED / HOT WATER SUPPLY RETURN ONNETIONS 6 5/8" (68) /2" () OPTIONAL SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET " (25) Filter Size Width x Height () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 2 x (58 x 254) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 25 x (65 x 254) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) x (762 x 254) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2@ 2 x (58 x 254) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 2@ 25 x (65 x 254) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 2@ x (762 x 254) 28" (7) ELETRI HEAT FAN " (25) THROWAWAY FILTER 2 /8" (54) RETURN AIR " (254) OPTIONAL BOTTOM BOTTOM RETURN MOUNT ONTROLS ENLOSURE, 9" (229) LEARANE REQUIRED HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 7

8 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H With Plenum 2-pipe Heating Only Model: 4HP Unit Sizes 5 TYPE W Hot Water Only (2-pipe). D (HANGER HOLES) - 2" (5) HANGER BRAKETS (TYP. 4) /8" () DIA. 5 /2" (4) 6" (52) 2" (5) 7 /4" (48) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 6 /4" (7) "J" BOX 4 x 4 "J" BOX (LINE VOLTAGE ONLY) OR ONTROLS ENLOSURE AS REQUIRED (FIELD REMOTE MOUNTABLE) Dimensional Data Unit Size Nominal FM (l/s) A (DISHARGE OLLAR) A B D HOT WATER SUPPLY RETURN ONNETIONS /2" () 6 5/8" (68) " (25) Filter Size Width x Height () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 2 x (58 x 254) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 25 x (65 x 254) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) x (762 x 254) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2@ 2 x (58 x 254) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 2@ 25 x (65 x 254) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 2@ x (762 x 254) 28" (7) " (25) THROWAWAY FILTER FAN 2 /8" (54) RETURN AIR " (254) OPTIONAL OPTIONAL BOTTOM BOTTOM RETURN MOUNT ONTROLS ENLOSURE, 9" (229) LEARANE REQUIRED 8

9 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Telescoping 2 or 4 Pipe ooling/heating Model: 4HT Unit Sizes 5 TYPE Z TYPE ZW hilled/hot Water (2-pipe). hilled & Hot Water (4-pipe). D (HANGER HOLES) HANGER BRAKETS (TYP. 4) /8" () DIA. 5 /2" (4) 6" (52) 2" (5) 7 /4" (48) 6 /4" (7) /2" (8) "J" BOX 4 x 4 "J" BOX (LINE VOLTAGE ONTROL ONLY) OR ONTROLS ENLOSURE AS REQUIRED Dimensional Data Unit Size Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN 4 /4" (2) 2" (55) MAX. OPTIONAL AUX. DRIP PAN A B D DRAIN PAN OUTLET HILLED / HOT WATER SUPPLY RETURN ONNETIONS () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 (575) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 6 5/8" (68) /2" () OPT. SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET " (25) OPTIONAL BOTTOM MOUNTED HINGED DOOR ONTROLS ENLOSURE 9" (229) LEARANE REQUIRED 28" (7) FAN HINGED " (254) /2" (89) MIN. TO 5 /2" (4) MAX. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 9

10 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Telescoping 2 or 4 Pipe ooling/heating Model: 4HT Unit Sizes 5 (continued) TYPE Z TYPE ZW hilled/hot Water (2-pipe). hilled & Hot Water (4-pipe). BOTTOM PANEL ASSEMBLY A 7/8" (22) 6 5/8" (68) FAN " (254) F E OPTIONAL BOTTOM MOUNTED HINGED DOOR ONTROLS ENLOSURE 9" (229) LEARANE REQUIRED TELESOPING SKIRT /2" (85) 29 /4" (756) /2" (89) MIN. TO 5 /2" (4) MAX. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Dimensional Data Unit Size /2" (85) " (279) /2" (89) " (254) E F G Filter Size Width x Height 9 /4 () 4 /2 (5) 2 (58) 2 x (58 x 254) 4 44 /4 (7) 48 /2 (22) 25 (65) 25 x (65 x 254) 6 49 /4 (264) 5 /2 (59) (762) x (762 x 254) 8 59 /4 (58) 6 /2 (6) 4 (6) 2@ 2 x (58 x 254) 2 69 /4 (772) 7 /2 (867) 5 (27) 2@ 25 x (65 x 254) 5 79 /4 (226) 8 /2 (22) 6 (524) 2@ x (762 x 254) G F /4 TURN FASTENERS 45 LOUVERED RETURN GRILLE WITH " (25) THROWAWAY FILTER Note:. Left hand unit as shown, right hand unit is built as mirror image. 2. Telescoping skirt and collar assembly must be field adjusted to assure a proper fit between filter frame and louvered inlet panel assembly. In the event the louvered return grille is larger/smaller or does not align with the telescoping skirt, additional field modifications may be needed to prevent ceiling plenum air from being entrained into return plenum.. /4-turn tabs. (2) Qty. for sizes and 4, () Qty. for sizes 6 and 8, (4) qty. for sizes 2 and Minimum ceiling drywall opening should be cut as Panel Assembly neck dimension E x 29 /4" (756) plus /4" (6).

11 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Telescoping 2 Pipe ooling and Electric Heat Model: 4HT Unit Sizes 5 TYPE ZE hilled/hot Water (2-pipe) & Electric Heat. D (HANGER HOLES) HANGER BRAKETS (TYP. 4) /8" () DIA. 7 /4" (48) Dimensional Data Unit Size /2" (8) Nominal FM (l/s) A B A (DISHARGE OLLAR) SLOPED DRAIN PAN 4 /4" (2) 2" (55) MAX. OPTIONAL AUX. DRIP PAN A B D DRAIN PAN OUTLET HILLED WATER SUPPLY RETURN ONNETIONS () 2 (58) 26 /2 (67) 2 /8 (58) 22 5/8 575) 4 4 () 25 (66) /2 (8) 25 /8 (645) 27 5/8 (72) 6 6 (28) (762) 6 /2 (927) /8 (772) 2 5/8 (829) 8 8 (78) 4 (6) 46 /2 (8) 4 /8 (26) 42 5/8 (8) 2 2 (566) 5 (27) 56 /2 (45) 5 /8 (286) 52 5/8 (7) 5 5 (78) 6 (524) 66 /2 (689) 6 /8 (54) 62 5/8 (59) 6 5/8" (68) /2" () OPT. SEONDARY DRAIN OUTLET PRIMARY DRAIN OUTLET " (25) BOTTOM MOUNTED HINGED DOOR ONTROLS ENLOSURE 9" (229) LEARANE REQUIRED 28" (7) ELETRI HEAT FAN HINGED " (254) /2" (89) MIN. 5 /2" (4) MAX. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM

12 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Telescoping 2 Pipe ooling and Electric Heat Model: 4HT Unit Sizes 5 (continued) TYPE ZE hilled/hot Water (2-pipe) and Electric Heat. BOTTOM PANEL ASSEMBLY A ELETRI HEAT 7/8" (22) 6 5/8" (68) FAN " (254) F E BOTTOM MOUNTED HINGED DOOR ONTROLS ENLOSURE 9" (229) LEARANE REQUIRED /2" (85) 29 /4" (756) TELESOPING SKIRT /2" (89) MIN. TO 5 /2" (4) MAX. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Dimensional Data Unit Size /2" (85) " (279) /2" (89) " (254) E F G Filter Size Width x Height 9 /4 () 4 /2 (5) 2 (58) 2 x (58 x 254) 4 44 /4 (7) 48 /2 (22) 25 (65) 25 x (65 x 254) 6 49 /4 (264) 5 /2 (59) (762) x (762 x 254) 8 59 /4 (58) 6 /2 (6) 4 (6) 2@ 2 x (58 x 254) 2 69 /4 (772) 7 /2 (867) 5 (27) 2@ 25 x (65 x 254) 5 79 /4 (226) 8 /2 (22) 6 (524) 2@ x (762 x 254) G F /4 TURN FASTENERS 45 LOUVERED RETURN GRILLE WITH " (25) THROWAWAY FILTER Note:. Left hand unit as shown, right hand unit is built as mirror image. 2. Telescoping skirt and collar assembly must be field adjusted to assure a proper fit between filter frame and louvered inlet panel assembly. In the event the louvered return grille is larger/smaller or does not align with the telescoping skirt, additional field modifications may be needed to prevent ceiling plenum air from being entrained into return plenum.. /4-turn tabs. (2) Qty. for sizes and 4, () Qty. for sizes 6 and 8, (4) qty. for sizes 2 and Minimum ceiling drywall opening should be cut as Panel Assembly neck dimension E x 29 /4" (756) plus /4" (6). 2

13 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Exposed abinet 2 or 4 Pipe ooling or/and Heating Front Supply & Bottom Return Grille Model: 4HX Unit Sizes 5 TYPE Z TYPE ZW hilled/hot Water (2-pipe). hilled & Hot Water (4-pipe). /2" (25) D - HANGER HOLES E 8 /2" (26) /8"() DIA. HANGER ROD HOLES WITH RESILIENT GROMMETS Dimensional Data Unit Size " (787) 27" (686) 2" (5) 2" (5) 7" (78) Nominal FM (l/s) 4 x 4 "J" BOX (LINE VOLTAGE ONTROL ONLY) OR ONTROLS ENLOSURE AS REQUIRED OPTIONAL AUXILIARY DRIP PAN PRIMARY DRAIN OUTLET OPTIONAL SEONDARY DRAIN OUTLET A SUPPLY GRILLE B " (787) (SINGLE DEFLETION) FIXED 45 RETURN GRILLE AND FILTER FILTER SIZE: E x 8 /2" (26) 6 /2" (65) A B D /4 TURN FASTENER () 9 (99) 2 (58) 6 (94) 25 (65) 4 4 () 44 (8) 25 (65) 4 (4) (762) 6 6 (28) 49 (245) (762) 46 (68) 5 (889) 8 8 (78) 59 (499) 4 (6) 56 (2) 45 (4) 2 2 (566) 69 (75) 5 (27) 66 (676) 55 (97) 5 5 (78) 79 (27) 6 (524) 76 (9) 65 (65) 5/8" (4) /8" (29) DIA. DRAIN K.O. /6" (97) 7/8" (22) DIA. ELE. K.O. 7/8" (48) " (76) REAR VIEW OPTIONAL BOTTOM MOUNT HINGED DOOR ONTROLS ENLOSURE 7/8" (22) DIA. ELE. K.O. FAN 8 /2" (26) /4" (95) /2" (89) 2" (5) 2 /2" (64) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM

14 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Exposed abinet 2 Pipe ooling & Electric Heat Front Supply & Bottom Return Grille Model: 4HX Unit Sizes 5 TYPE ZE hilled/hot Water (2-pipe) and Electric Heat. /2" (25) D - HANGER HOLES E 8 /2" (26) /8"() DIA. HANGER ROD HOLES WITH RESILIENT GROMMETS HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM " (787) 27" (686) 2" (5) 2" (5) 7" (78) Dimensional Data Unit Size Nominal FM (l/s) FIXED 45 RETURN GRILLE AND FILTER FILTER SIZE: E x 8 /2" (26) OPTIONAL AUXILIARY DRIP PAN 6 /2" (65) 5/8" (4) /4 TURN FASTENER /8" (29) DIA. DRAIN K.O. 7/8" (22) DIA. ELE. K.O. BOTTOM MOUNT HINGED DOOR ONTROLS ENLOSURE 7/8" (22) DIA. ELE. K.O. 7/8" (48) /6" " (97) (76) REAR VIEW PRIMARY DRAIN OUTLET OPTIONAL SEONDARY A DRAIN OUTLET B SUPPLY GRILLE " (787) (SINGLE DEFLETION) ELETRI HEAT A B D () 9 (99) 2 (58) 6 (94) 25 (65) 4 4 () 44 (8) 25 (65) 4 (4) (762) 6 6 (28) 49 (245) (762) 46 (68) 5 (889) 8 8 (78) 59 (499) 4 (6) 56 (2) 45 (4) 2 2 (566) 69 (75) 5 (27) 66 (676) 55 (97) 5 5 (78) 79 (27) 6 (524) 76 (9) 65 (65) FAN 8 /2" (26) /4" (95) /2" (89) 2" (5) 2 /2" (64) 4

15 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model 4HF Free Return PS Motor Fan Performance urves Airflow vs. External Static Pressure l/s FM 5 65 Unit Size l/s FM 6 28 Unit Size 4 l/s FM 8 78 Unit Size l/s FM Unit Size "w.g Pa EXTERNAL STATI PRESSURE "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 4 2 l/s FM Unit Size "w.g Pa EXTERNAL STATI PRESSURE "w.g Pa EXTERNAL STATI PRESSURE HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM PS Motor Fan Notes:. Permanent split capacitor (PS) motors are of the three speed type with separate taps (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost. 2. All fan curves shown are for 2 volt single phase, -speed PS motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and filters, adjust performance curves based on pressure losses or use Selectworks. 4. Filter pressure drops table shown on page 2. 5

16 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Models 4HP Plenum & 4HT Telescoping PS Motor Fan Performance urves Airflow vs. External Static Pressure l/s FM 65 5 Unit Size l/s FM 6 28 Unit Size 4 l/s FM 8 78 Unit Size HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 2 l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 4 2 l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE PS Motor Fan Notes:. Permanent split capacitor (PS) motors are of the three speed type with separate taps (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost All fan curves shown are for 2 volt single phase, -speed PS motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and filters, adjust performance curves based on pressure losses or use Selectworks. 4. Filter pressure drops table shown on page 2.

17 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model 4HX Exposed abinet PS Motor Fan Performance urves Airflow vs. External Static Pressure l/s FM 5 65 Unit Size l/s FM 5 26 Unit Size 4 l/s FM 7 Unit Size l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 4 2 l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM PS Motor Fan Notes:. Permanent split capacitor (PS) motors are of the three speed type with separate taps (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost. 2. All fan curves shown are for 2 volt single phase, -speed PS motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and filters, adjust performance curves based on pressure losses or use Selectworks. 4. Filter pressure drops table shown on page 2. 7

18 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model 4HF Free Return -Speed EM Fan Performance urves Airflow vs. External Static Pressure l/s FM 5 65 Unit Size l/s FM 6 28 Unit Size 4 l/s FM 8 78 Unit Size HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 8 -Speed EM Motor Fan Notes:. Fan coil units equipped with -speed EM Motors have discrete inputs (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/ or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost. 2. Fan curves are applicable to all models. All fan curves shown are for 2 volt single phase, -speed EM Motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and addition of a filter, adjust performance curves based on pressure losses or use Selectworks. 4. Area within shaded area not predictable. 5. Filter pressure drops table shown on page 2.

19 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Models 4HP Plenum & 4HT Telescoping -Speed EM Fan Performance urves Airflow vs. External Static Pressure l/s FM 65 5 Unit Size l/s FM 28 6 Unit Size 4 l/s FM 78 8 Unit Size l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM -Speed EM Motor Fan Notes:. Fan coil units equipped with -speed EM Motors have discrete inputs (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/ or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost. 2. Fan curves are applicable to all models. All fan curves shown are for 2 volt single phase, -speed EM Motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and addition of a filter, adjust performance curves based on pressure losses or use Selectworks. 4. Area within shaded area not predictable. 5. Filter pressure drops table shown on page 2. 9

20 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model 4HX Exposed abinet -Speed EM Fan Performance urves Airflow vs. External Static Pressure l/s FM 5 65 Unit Size l/s FM 6 28 Unit Size 4 l/s FM 8 78 Unit Size HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE l/s FM "w.g Pa EXTERNAL STATI PRESSURE Unit Size "w.g Pa EXTERNAL STATI PRESSURE 2 -Speed EM Motor Fan Notes:. Fan coil units equipped with -speed EM Motors have discrete inputs (High, Medium and Low) which provide variable horsepower outputs. ommonly, units are selected and sized on a conservative basis and actual airflow and/ or external static pressure requirements are lower than specified. When this is the case, the unit fan motor can be run at low or medium speed, reducing power consumption and operating cost. 2. Fan curves are applicable to all models. All fan curves shown are for 2 volt single phase, -speed EM Motors and include internal losses for cabinet, electric heater and or 4 row water coil.. For other coil combinations and addition of a filter, adjust performance curves based on pressure losses or use Selectworks. 4. Area within shaded area not predictable. 5. Filter pressure drops table shown on page 2.

21 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Performance Data Electrical Motor haracteristics No. of -Speed PS Motor -Speed EM Unit Size Voltage Fans/ Full Load Full Load Motors HP FLA HP FLA Watts Watts 2 / /.4.8 / 89 /8 2 / / / /.8.4 /5 59 /8 2 / / / /.9.5 / 24 /8 2 2/ / / /..9 /6 29 /4 2 2/ /..6 2 / / /6 & /5 6 /8 & /4 2 / / / /2 2.. /6 4 /4 2 4/ / The FLA and watts are shown at the maximum setting for selected motor type and unit size. Refer to SelectWorks selection software for application specific data. Electric Heating Selection Unit Electric Heat Kilowatts Range Size 2V 28V 24V 277V HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM NOTES:. Electric heat voltage must be the same as motor voltage. 2. A minimum airflow of 7 cfm per kw is required across the coil during heating. Available in the above kw s only. kw x 6 T = FM Do not size heaters with leaving air temperature greater than 5 F (4 ).. oils are wired to the control panel for a single point electrical connection. 4. The coils listed are restricted to a maximum of 48 amps (with motor) and do not require circuit fusing to meet NE requirements. 5. Basic electric coils include: Automatic reset high limits and magnetic contactor for one stage control. 6. The basic list price does not include a disconnect switch. See control power package options for coil accessories. 2

22 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Filter Pressure Drop Adjustments (in w.g.) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Unit Size NOTES: Airflow Velocity Filter Type FM l/s FPM m/s " (25) Throwaway " (25) MERV Filter Size x 2 (254 x 58) x 25 (254 x 65) x (254 x 762) x 2 (254 x 58) x 25 (254 x 65) x (254 x 762). Pressure drop based on clean filters. Using any type of filter will lower unit airflow. 2. To determine fan airflow with the addition of a filter, add the filter pressure drop to the external static pressure on the fan curve or use Selectworks. Front: " (25) Throwaway Back: " (25) MERV 8 22

23 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Low Profile Performance Data Sound Data Unit Size Fan Speed Airflow Sound Power Levels Octave Bands FM l/s 2/25 /25 4/5 5/ 6/2 7/4 8/8 High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low Performance Notes:. Sound power levels in decibels, db re -2 watts. 2. All sound data listed by octave band is raw data without any corrections for room absorption or duct attenuation.. Total sound level data based on model 4HP with airflow at corresponding motor tap with 2 volt single phase, -speed PS motor, row coil, no filter and." external static pressure. dba 4. Data derived from independent tests conducted in accordance with AHRI Standard 5. HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 2

24 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Performance Data AHRI Standard Ratings ooling apacity HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Unit Size Water oil ooling apacity Water Power Airflow FM Input (Dry Flow) Flow Rate Rows onn. QT (BTUH) QS (BTUH) WPD ft. w.g. (GPM) (Watts) MODEL: 4HF FREE RETURN MODELS: 4HP PLENUM, 4HT TELESOPING MODEL: 4HX EXPOSED ABINET NOTES: Based on 8 F DB and 67 F WB EAT, 45 F EWT, F water temperature rise, high fan speed. Motor type is -speed PS, 2 volt single phase. Airflow under dry conditions. Models 4HF and 4HP tested at.5" w.g. external static pressure. Model 4HX tested at." w.g. external static pressure with filter. 24

25 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Performance Data Heating apacity Unit Size NOTES: Water oil Rows onn. Airflow FM MODEL: 4HF FREE RETURN Heating apacity (MBH) Based on 7 F DB EAT, 8 F EWT, 4 F water temperature drop, high fan speed. Models 4HF and 4HP tested at.5" w.g. external static pressure. Model 4HX tested at." w.g. external static pressure with filter. LAT ( F) Water Flow Rate WPD ft. w.g. (GPM) Power Input (Watts) MODELS: 4HP PLENUM, 4HT TELESOPING MODEL: 4HX EXPOSED ABINET HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 25

26 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H hilled Water oil Performance Data Unit Size Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water Row (Total MBH) 4 Row (Total MBH) GPM GPM 2 GPM 2 GPM 8 GPM 8 GPM TMBH 6 TMBH HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM FM 7 8 l/s Row (Sensible MBH) FM 7 8 l/s 4 Row (Sensible MBH) Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder. 26

27 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H hilled Water oil Performance Data Unit Size 4 Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water Row (Total MBH) 4 Row (Total MBH) 6.5 GPM 4 GPM TMBH GPM FM l/s Row (Sensible MBH) 4 Row (Sensible MBH) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder. 27

28 HORIZONTAL LOW PROFILE FAN OIL IN ROOM hilled Water oil Performance Data Unit Size 6 Model Series 4H Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water 25 Row (Total MBH) 4 Row (Total MBH) GPM GPM GPM 2 GPM 5 TMBH.5 GPM TMBH 5.5 GPM 5 5 HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM FM l/s Row (Sensible MBH) FM l/s 4 Row (Sensible MBH) Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder. 28

29 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H hilled Water oil Performance Data Unit Size 8 Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water Row (Total MBH) 4 Row (Total MBH) GPM 5.5 GPM 2 4 GPM 25 4 GPM 2 GPM 2 TMBH 5 TMBH 5.5 GPM FM l/s Row (Sensible MBH) FM l/s 4 Row (Sensible MBH) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder. 29

30 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H hilled Water oil Performance Data Unit Size 2 Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water Row (Total MBH) 4 Row (Total MBH) GPM 5 GPM TMBH GPM 5 5 HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM FM l/s Row (Sensible MBH) 4 Row (Sensible MBH) Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder.

31 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H hilled Water oil Performance Data Unit Size 5 Data Based on 8 F DB, 67 F WB Entering Air & 45 F Entering Water Row (Total MBH) 4 Row (Total MBH) SMBH Row (Sensible MBH) 9.5 GPM 6 GPM 4 GPM GPM FM l/s SMBH Row (Sensible MBH) 9.5 GPM 6 GPM 4 GPM GPM FM l/s HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Altitude orrection Factors Altitude (ft.) Air Density (lb./cu. ft) Total apacity Sensible apacity Static Pressure NOTES:. apacity and static pressure will be affected for applications above sea level. To apply correction factors, multiply the coil capacity or fan curve data by the tabulated correction factor. 2. onnections: and 4 Row 7/8" (22.2) O.D. male solder.

32 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Hot Water oil Performance Data Unit Size Data Based on 7 F DB Entering Air & 8 F Entering Water Row (Total MBH) 2 Row (Total MBH) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Unit Size 4 Row (Total MBH) NOTES:. apacities are in MBH (kw), thousands of Btu per hour (kilowatts). 2. MBH (kw) values are based on a t (temperature difference) of F (6 ) between entering air and entering water. For other t's; multiply the MBH (kw) values by the factors below. orrection factors at other entering conditions: 2 Row (Total MBH). Air Temperature Rise. ATR ( F) = 927 x MBH, ATR ( ) = 829 x kw FM l/s 4. Water Temp. Drop. WTD ( F) = 2.4 x MBH, WTD ( ) =.224 x kw GPM l/s 5. onnections: Size and size 4, one and two row 5/8" (6) O.D. male solder. Altitude orrection Factors: Altitude ft. (m) () 2 (6) (94) 4 (29) 5 (524) 6 (829) 7 (24) Sensible Heat Factor t F ( ) 5 (28) 6 () 7 (9) 8 (44) 9 (5) (56) (6) 2 (67) (72) 4 (78) 5 (8) Factor.455 (.459).545 (.54).66 (.69).727 (.72).88 (.82).99 (.98). (.).9 (.).8 (.8).27 (.28).6 (.6) 2

33 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Hot Water oil Performance Data Unit Size 6 Data Based on 7 F DB Entering Air & 8 F Entering Water Row (Total MBH) 2 Row (Total MBH) Unit Size 8 Row (Total MBH) NOTES:. apacities are in MBH (kw), thousands of Btu per hour (kilowatts). 2. MBH (kw) values are based on a t (temperature difference) of F (6 ) between entering air and entering water. For other t's; multiply the MBH (kw) values by the factors below. orrection factors at other entering conditions: 2 Row (Total MBH). Air Temperature Rise. ATR ( F) = 927 x MBH, ATR ( ) = 829 x kw FM l/s 4. Water Temp. Drop. WTD ( F) = 2.4 x MBH, WTD ( ) =.224 x kw GPM l/s 5. onnections: Size 6 and size 8, one and two row 5/8" (6) O.D. male solder. Altitude orrection Factors: Altitude ft. (m) () 2 (6) (94) 4 (29) 5 (524) 6 (829) 7 (24) Sensible Heat Factor t F ( ) 5 (28) 6 () 7 (9) 8 (44) 9 (5) (56) (6) 2 (67) (72) 4 (78) 5 (8) Factor.455 (.459).545 (.54).66 (.69).727 (.72).88 (.82).99 (.98). (.).9 (.).8 (.8).27 (.28).6 (.6) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM

34 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Hot Water oil Performance Data Unit Size 2 Data Based on 7 F DB Entering Air & 8 F Entering Water Row (Total MBH) 2 Row (Total MBH) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM 4 Unit Size 5 Row (Total MBH) NOTES:. apacities are in MBH (kw), thousands of Btu per hour (kilowatts). 2. MBH (kw) values are based on a t (temperature difference) of F (6 ) between entering air and entering water. For other t's; multiply the MBH (kw) values by the factors below. orrection factors at other entering conditions: 2 Row (Total MBH). Air Temperature Rise. ATR ( F) = 927 x MBH, ATR ( ) = 829 x kw FM l/s 4. Water Temp. Drop. WTD ( F) = 2.4 x MBH, WTD ( ) =.224 x kw GPM l/s 5. onnections: Size 2 and size 5, one and two row 5/8" (6) O.D. male solder. Altitude orrection Factors: Altitude ft. (m) () 2 (6) (94) 4 (29) 5 (524) 6 (829) 7 (24) Sensible Heat Factor t F ( ) 5 (28) 6 () 7 (9) 8 (44) 9 (5) (56) (6) 2 (67) (72) 4 (78) 5 (8) Factor.455 (.459).545 (.54).66 (.69).727 (.72).88 (.82).99 (.98). (.).9 (.).8 (.8).27 (.28).6 (.6)

35 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H oil Performance Data Pressure Drop Unit Size hilled Water Pressure Drop Hot Water Pressure Drop hilled and Hot Water Air Pressure Drop HEAD LOSS (WATER PRESSURE DROP), F.T. WATER 2 HEAD LOSS (WATER PRESSURE DROP), F.T. WATER ROW ROW AIR PRESSURE DROP, INHES W.G (OOL) (OOL) 2 ROW (HOT) ROW (HOT) HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Unit Size 4 hilled Water Pressure Drop WATER FLOW, GPM HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Hot Water Pressure Drop ,5 2 ROW ROW WATER FLOW, GPM , FM hilled and Hot Water Air Pressure Drop AIR PRESSURE DROP, INHES W.G , FM (OOL) (OOL) 2 ROW (HOT) ROW (HOT) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Metric onversion Factors:. Water Flow (liters per second) l/s = gpm x Water Head Loss (kilopascals): kpa = ft. w.g. x Airflow Volume (liters per second) l/s = FM x.2 4. Air Pressure Drop (Pascals): Pa = in. w.g. x Heat (kilowatts): kw = Mbh x Air Temperature Rise. ATR = 927 x Mbh FM 7. Water Temp. Drop. WTD = 2.4 x Mbh GPM 5

36 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H oil Performance Data Pressure Drop Unit Size 6 hilled Water Pressure Drop 2 Hot Water Pressure Drop 4. hilled and Hot Water Air Pressure Drop.45 HEAD LOSS (WATER PRESSURE DROP), F.T. WATER HEAD LOSS (WATER PRESSURE DROP), F.T. WATER ,5 2 ROW ROW AIR PRESSURE DROP, INHES W.G (OOL) (OOL) 2 ROW (HOT) ROW (HOT) HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Unit Size 8 hilled Water Pressure Drop WATER FLOW, GPM HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Hot Water Pressure Drop ,5 ROW 2 ROW WATER FLOW, GPM AIR PRESSURE DROP, INHES W.G , FM hilled and Hot Water Air Pressure Drop 2 ROW (HOT) ROW (HOT) , FM (OOL) (OOL) 6 Metric onversion Factors:. Water Flow (liters per second) l/s = gpm x Water Head Loss (kilopascals): kpa = ft. w.g. x Airflow Volume (liters per second) l/s = FM x.2 4. Air Pressure Drop (Pascals): Pa = in. w.g. x Heat (kilowatts): kw = Mbh x Air Temperature Rise. ATR = 927 x Mbh FM 7. Water Temp. Drop. WTD = 2.4 x Mbh GPM

37 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H oil Performance Data Pressure Drop Unit Size 2 hilled Water Pressure Drop Hot Water Pressure Drop hilled and Hot Water Air Pressure Drop HEAD LOSS (WATER PRESSURE DROP), F.T. WATER HEAD LOSS (WATER PRESSURE DROP), F.T. WATER ROW 2 ROW AIR PRESSURE DROP, INHES W.G (OOL) (OOL) 2 ROW (HOT) ROW (HOT) HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Unit Size 5 hilled Water Pressure Drop WATER FLOW, GPM HEAD LOSS (WATER PRESSURE DROP), F.T. WATER WATER FLOW, GPM Hot Water Pressure Drop ROW 2 ROW WATER FLOW, GPM , FM hilled and Hot Water Air Pressure Drop AIR PRESSURE DROP, INHES W.G (OOL) (OOL) 2 ROW (HOT) ROW (HOT) , FM HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM Metric onversion Factors:. Water Flow (liters per second) l/s = gpm x Water Head Loss (kilopascals): kpa = ft. w.g. x Airflow Volume (liters per second) l/s = FM x.2 4. Air Pressure Drop (Pascals): Pa = in. w.g. x Heat (kilowatts): kw = Mbh x Air Temperature Rise. ATR = 927 x Mbh FM 7. Water Temp. Drop. WTD = 2.4 x Mbh GPM 7

38 HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model Series 4H Suggested Specifications HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM. General Furnish and install Engineered omfort Model 4H Series Low Profile Horizontal Fan oil Units where indicated on the plans and in the specifications. 2. onstriction a. All units shall be Direct Drive Blow Through configuration and completely factory assembled, tested and shipped as one piece. All units shall be capable of meeting or exceeding the scheduled capacities for cooling, heating and air delivery. All unit dimensions, for each model and size, shall be considered maximums. Units shall be UL or ETL, listed in compliance with UL/ANSI Standard, and be certified as complying with the latest edition of AHRI Standard 44 and meets the requirements of NFPA 9A and UL 8. b. All unit chassis shall be fabricated of heavy gauge galvanized steel panels able to meet 25 hour salt spray test per ASTM B-7. 8 ga. (.) galvanized steel channel frame. All panels shall be insulated with /2" () thick closed cell Fiber-free/ foam and rated for air velocity of 6 FPM Insulation must meet all requirements of ASTM 7 (including 665), UL 8 for erosion, and carry a 25/5 rating for flame spread/smoke developed per ASTM E-84, UL 72 and NFPA 9A. c. Unit cabinet shall have side and bottom full size access panels (if applicable) on 4H for ease of maintenance and service and motor blower removal. Access panels shall be attached to casing with screws. Optional Aluminum foil-faced insulation (steri-liner), meets ASTM Standards -665 and -6 for biological growth in insulation. All exposed edges shall be sealed to prevent any fibers from reaching the air stream. lose cell fiber-free liner. Insulation shall conform to UL 8 for erosion and NFPA 9A for fire, smoke and melting, and comply with a 25/5 Flame Spread and Smoke Developed Index per ASTM E-84 or UL 72. Additionally, insulation shall comply with Antimicrobial Performance Rating of, no observed growth, per ASTM G-2. d. Unit shall be blow through type with fan dynamically balanced, forwardly curved; DWDI centrifugal type constructed of 8 (.) gauge zinc coated galvanized steel for corrosion resistance. The fan assembly shall be removable for servicing the motor and blower at, or away from the unit. 5. Motor Motor shall be direct drive, isolated from blower and fan housing in two locations with rubber isolators to eliminate any motor vibration being transmitted to the fan housing and duct. Motors shall be high efficiency, permanently lubricated sleeve bearing. Motor wires shall be brought into external hinged door starter- control enclosure to facilitate wiring and service. Motors shall of the Permanent Split apacitor type with UL and SA listed automatic reset thermal overload protection and three separate horsepower taps. 6. Sound Units shall have discharge and radiated sound power levels published and tested in accordance with AHRI Standard oils All water coils shall be AHRI 4 certified and tagged with an AHRI 4 label. All coils shall be pressure tested under water at.5 times the working pressure classification indicated in the ontract Documents, but the test pressure in no case shall be less than psig. oils shall have /2" () O.D. seamless copper tubes, and collared and corrugated aluminum fins. Tube wall thickness of.6 to be standard. oil frames shall be constructed of minimum G-9 galvanized steel. Water velocity in the tubes shall not exceed eight (8) feet per second and the coil face velocity shall not exceed 5 fpm. For 4 pipe system a separate heating coil shall be furnished in the reheat position as standard. Optional For 4 pipe system, a separate heating coil shall be furnished in the preheat position. oil tube wall thickness shall be.25 in All coils without piping packages shall be provided with a manual air vent fitting to reduce potential air locks within coil. All coils shall be provided with an auto air vent fitting to allow for coil venting. 8. Primary condensate drain pans shall be heavy gauge galvanized steel, and extend under the entire cooling coil. Drain pans shall be of one-piece construction, have at least " (25) height side and be positively sloped for condensate removal. The drain pan shall be externally insulated with minimum /8" thick fire retardant, closed cell foam insulation. The insulation shall carry no more than a 25/5 Flame Spread and Smoke Developed Rating per ASTM E-84 and UL 72 and an Antimicrobial Performance Rating of "", no observed growth, per ASTM G-2. Optional Provide a primary drain pan constructed entirely of heavy gauge stainless steel for superior corrosion resistance. Stainless steel drain pans shall be externally insulated and meet or exceed the requirements stated above. Provide a secondary drain connection on the primary drain pan for condensate overflow. Provide a condensate overflow switch in the primary drain pan for condensate overflow. 9. Standard units can be ordered without filters (4HF excluded). Optional Filter: Unit to be furnished with a minimum " (25) nominal glass fiber throwaway filter. Filters shall be tight fitting to prevent air bypass. Provide unit with " (25) or 2" (5) pleated filters rated at 25-% efficiency and MERV 8 based on ASHRAE Electrical Units shall be furnished with a hinged door starter-control enclosure and wired single point power connection. All power and control wiring shall conform to National Electric ode Standards. Within the control enclosure it shall include all required devices, including but not limited to, service switch, relay, control power transformers and control packages, low voltage remote shutdown relays, etc. Optional 4" x 4" (2 x 2) junction box or controls enclosure (field remote mountable).. Electric heat a. Furnish an electric resistance heating assembly as an integral part of the fan coil unit, with the heating capacity, voltage and kilowatts scheduled. The heater assembly shall be designed and rated for installation on the fan coil unit without the use of duct extensions or transitions, and be located in the unit as to not expose the fan assembly to excessive leaving air temperatures that could affect motor performance. b. The heater and unit assembly shall be listed for zero clearance and meet all NE requirements, and be ETL listed with the unit as an assembly in compliance with UL/ANSI Standard. A NEMA enclosure with hinges shall be placed at the side of the fan coil to provide easy access. All motor wiring and heater terminates in the enclosure for single point electrical connection. c. All heating elements shall be open coil type high grade lass A 8/2 nickel/chrome wire mounted in ceramic insulators and located in an insulated heavy gauge galvanized steel housing. All elements shall terminate in a machine staked stainless steel terminal secured with stainless steel hardware for corrosion resistance. The element support brackets shall be spaced no greater than -/2" (9) on center. All internal wiring shall be rated for 22 F (5 ) minimum. All heaters shall include over temperature protection consisting of an automatic reset primary 8

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

engineering guide FH Fan-Coil Units Low-Profile, Horizontal engineering guide FH Fan-Coil Units Low-Profile, Horizontal FORM 115.26-EG7 (908) Table of contents FH Fan-Coil Units Low-Profile, Horizontal Features and Benefits... Construction Features... Standard

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at Horizontal and Vertical DIRECT DRIVE BER COIL UNITS Rating and selection at www.enviro-tec.com CDH/CDV TABLE OF CONTENTS Construction Features...3 Fan Assembly...4 Optional Construction...5 Electric Heat...6

More information

catalog CDV Fan-Coil Units High-Performance, Vertical

catalog CDV Fan-Coil Units High-Performance, Vertical catalog CDV Fan-Coil Units High-Performance, Vertical Catalog: ET115.26-EG8 (415) TABLE OF CONTENTS CDV Fan-Coil Units High-Performance, Vertical Features and Benefits... 3 Construction Features... 4 Standard

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

engineering guide FN Fan-Coil Units High-Performance, Horizontal

engineering guide FN Fan-Coil Units High-Performance, Horizontal engineering guide FN Fan-Coil Units High-Performance, Horizontal Form 115.26-EG3 (909) TABLE OF CONTENTS High-Performance, Horizontal Fan-Coil Units Features and Benefits...3 Unit Arrangements...4 Construction

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

PRODUCT CATALOG BLOWER COILS.

PRODUCT CATALOG BLOWER COILS. 2016 PRODUCT CATALOG BLOWER COILS www.superiorrex.com SBH / SBV Series Design Features DESIGNED FOR MAXIMUM FLEXIBILITY Both Horizontal and Vertical Belt Drive Blower Coils are designed to maximize flexibility

More information

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32

More information

SSL & SBS Engineering Guide

SSL & SBS Engineering Guide REDUCED-FOOTPRINT VERTICAL BLOWER COIL UNITS SSL & SBS Engineering Guide SO TOUGH, WE GUARANTEE IT. SSL SBS Table of Contents Features and Benefits... 3 Construction Features... 4 Features and Options...

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SO TOUGH, WE GUARANTEE IT. SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SSL SBS www.superiorrex.com SSL / SBS Series: BIG ON FEATURES; SMALL IN SIZE Contractors All SSL/SBS model blower-coil

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

RAV Engineering Guide

RAV Engineering Guide VERTICAL HIGH-RISE FAN COIL UNITS RAV Engineering Guide SO TOUGH, WE GUARANTEE IT. RAVM RAVL RAVE RAVS RARM RARS RARP Table of Contents Features and Benefits... 3 Construction Features... 4 Standard and

More information

SECTION FAN COIL UNITS

SECTION FAN COIL UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

Vertical V*B Series Fan Coil Technical Catalog

Vertical V*B Series Fan Coil Technical Catalog Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with

More information

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog HiLine Vertical Stacking Fan Coils Type FHSS and FHSK Catalog 770-17 Table of Contents Introduction.... 3 Daikin Applied HiLine Fan-Coil Units...3 Nomenclature...3 Introduction.... 4 Low CFM design (300

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models Large Capacity Fan Coil Units Catalog 735-12 Belt-Drive and Direct-Drive Cabinet and Hideaway Models Table of Contents Agency Listing and Nomenclature... 3 Overview....................................

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway Catalog C: 735-7 Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway Direct Drive CUL Listed McQuay Large Capacity Fan Coil Units Page 2 / Catalog 735 Direct drive hideaway unit The

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC

VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC VAV TABLE OF CONTENTS FS/ rueger models FS and fan powered terminal units were designed for optimal performance in noise sensitive applications. These series and parallel fan terminals utilize built-in

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE MANUAL INSTALLATION, OPERATION, & MAINTENANCE Vertical Concealed Fan Coil FCVC Series v100 Issue Date: 12/21/15 2015 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG BUILD YOUR REPUTATION ON OURS Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG TABLE OF CONTENTS 2 Table of Contents 3 Universal Modular Hi-Rise Family 4 Features and benefits 5 Product Application

More information

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any

More information

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration Destiny Indoor Air Handler Models 002 030 Catalog 580-8 Horizontal Configuration Vertical Configuration Table of Contents Introduction.... 2 Certification...2 Smoke Control and Management Systems...2 Features

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

Electric Coils. Blower Coils. Product Information

Electric Coils. Blower Coils. Product Information Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact

More information