This parts list is current as of the above revision date. See for the current revision.

Size: px
Start display at page:

Download "This parts list is current as of the above revision date. See for the current revision."

Transcription

1 URM- Parts List This parts list is current as of the above revision date. See for the current revision. Package Gas-Electric

2 Table of Contents Model Explanation Page 3 Parts Numbers Drawings/Photographs Panels - Miscellaneous Page 4 Panels - Miscellaneous Page 5 Electrical Group Page 6 Fan Group Page 7 Blower Group Page 7 Coil Parts Page 8 Compressor Group Page 8 Heat Exchanger-Burner Group Page 9 Gas Controls Page 9 ccessories Page 10 Orifice Selection Chart Page 11 Exploded View Page 12 Control Box ssembly Page 13 Blower ssembly Page 14 Evaporator Coil ssembly Page 15 Evaporator Coils Baffles Page 15 Condenser Coil Group Page 16 Heat Exchanger ssembly Page 17 Burner ssembly Page 18 Notes Page 19 Page 2 of URM-

3 MODEL NUMBER EXPLNTION * R M K 1 0 E (1) TRDENME IDENTIFICTION (7) ELECTRICL DESIGNTION = 208/230V -1 PH - 60 HZ. (2) PRODUCT CLSSIFICTION C = 208/230V -3 PH - 60 HZ. R = ROOFTOP (8) DRIVE PCKGE (3) EFFICIENCY DESIGNTION K = DIRECT DRIVE (4) DESIGN SERIES (9) HETING CPCITY - (MBH) = FIRST DESIGN 04 = 40, = 60,000 (5) TECHNICL VRITIONS 08 = 80, = 100,000 (6) COOLING CPCITY (BTU/HR) 018 = 18, = 42,000 (10) IGNITION SYSTEM 024 = 24, = 48,000 E = ELECTRIC 030 = 30,000 X = ELECTRIC NOX 036 = 36,000 (11) OPTION CODES SERIL NUMBER EXPLNTION 1 R D F (1) GS CODE (7) TECHNOLOGY VRITIONS (2) BLOWER CONTROL BORD (8) PLNT F = FORT SMITH, R (3) COMPRESSOR IDENTIFICTION NUMBER (9) WEEK (4) IGNITION DEVICE (10) YER (5) INDUCER BLOWER (11) PRODUCTION NUMBER (6) HET EXCHNGER Page 3 of URM-

4 MODEL No. Notes TECHNICL VRITION COOLING CPCITY PNELS, MISCELLNEOUS PRTS 1 Front Base Pan - Before F3405 S S S Front Base Pan - fter F3405 S S S Base Rail (2) E E E Back Base Pan - Before F3605 S S S Back Base Pan - fter F3605 S S S Blower Shelf S S S Blower Shelf Transition S S S Divider Panel S S S Bulkhead ssembly S S S Exhaust Hood S S S Corner Post S S S Blower ccess Panel S S S End Panel S S S Supply Cover - Downflow S S S Supply Cover - Side Option S S S Return Cover - Downflow S S S Return Cover - Side Option S S S Top Panel S S S Grille S S S Fan Motor See Fan Group 17 Fan Blade See Fan Group 18 Venturi E E E Filter ccess Panel S S S Condenser Louver Panel S S S Center Post E E E Control ccess Panel S S S Compressor See Compressor Group 24 Heat Exchanger See Heat Exchanger Group 24d Collector Box See Heat Exchanger Group 25 Induced Draft Blower w/gasket See Electrical Group 26 Control Box (w/o components) E E E Control Box Cover E E E Furnace Shelf S S S Burner Floor E E E Exhaust Transition S S S Burner ssembly See Burner Group Combustion ir Inlet Hood E E E Bulkhead Valve (2) Bulkhead Valve Locknut (2) Bulkhead Valve Cap (2) Heat Exchanger Tube Support E E E Grommet - Gas Supply Piping URM- 018 URM- 024 URM- 030 Page 4 of URM-

5 MODEL No. Notes TECHNICL VRITION COOLING CPCITY PNELS, MISCELLNEOUS PRTS 1 Front Base Pan - Before F3405 S S S Front Base Pan - fter F3405 S S S Base Rail (2) E E E Back Base Pan - Before F3605 S S S Back Base Pan - fter F3605 S S S Blower Shelf S S S Blower Shelf Transition S S S Divider Panel S S S Bulkhead ssembly S S S Exhaust Hood S S S Corner Post S S S Blower ccess Panel S S S End Panel S S S Supply Cover - Pictured S S S Supply Cover - Side Option S S S Return Cover - Pictured S S S Return Cover - Side Option S S S Top Panel S S S Grille S S S Fan Motor See Fan Group 17 Fan Blade See Fan Group 18 Venturi E E E Filter ccess Panel S S S Condenser Louver Panel S S S Center Post E E E Control ccess Panel S S S Compressor See Compressor Group 24 Heat Exchanger See Heat Exchanger Group 24d Collector Box See Heat Exchanger Group 25 Induced Draft Blower w/gasket See Electrical Group 26 Control Box (w/o components) E E E Control Box Cover E E E Furnace Shelf S S S Burner Floor E E E Exhaust Transition S S S Burner ssembly See Burner Group Combustion ir Inlet Hood E E E Bulkhead Valve (2) Bulkhead Valve Locknut (2) Bulkhead Valve Cap (2) Heat Exchanger Tube Support E E E Grommet - Gas Supply Piping URM- 036 URM- 042 URM- 048 Page 5 of URM-

6 MODEL URM- URM- URM- URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION ELECTRICL GROUP 25 Stk Induced Draft Blower w/gasket Gasket - Induced Draft Blower Stk Contactor Stk Pressure Switch Integrated Furnace Control Board (IFC) See Gas Controls 35 Stk Transformer Capacitor - Blower Motor See Blower Group 37 Capacitor - Compressor/Fan See Compressor Group 37 Capacitor - Fan Only See Fan Group 51 Limit Control - Flame Roll-Out See the Heat Exchanger/Burner Group Stk Compressor Time Delay Control Stk Blower Control Board Time Delay Relay N/ Limit Control (On Blower Shelf) See the Heat Exchanger/Burner Group Wiring Harness - 9 pin to 6 pin and 4 flag terminals (6 pin to Fan Board) S S S S S S Wiring Harness - 9 pin to 9 terminals S S S S S S Leadwire - from Flame Sensor to 9 pin Wiring Harness Plug Capacitor daptor Plate (2 in. round capacitor) E E E E E E Capacitor daptor Plate (2 in. X 1-1/4 in. oval capacitor) E E E E E E MODEL URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION C C C ELECTRICL GROUP 25 Stk Induced Draft Blower w/gasket Gasket - Induced Draft Blower Contactor Stk Pressure Switch Integrated Furnace Control Board (IFC) See Gas Controls 35 Stk Transformer Capacitor - Blower Motor See Blower Group 37 Capacitor - Compressor/Fan See Compressor Group 37 Capacitor - Fan Only See Fan Group 51 Limit Control - Flame Roll-Out See the Heat Exchanger/Burner Group Stk Compressor Time Delay Control Stk Blower Control Board Time Delay Relay N/ Limit Control (On Blower Shelf) See the Heat Exchanger/Burner Group Wiring Harness - 9 pin to 6 pin and 4 flag terminals (6 pin to Fan Board) S S S Wiring Harness - 9 pin to 9 terminals S S S Leadwire - from Flame Sensor to 9 pin Wiring Harness Plug Capacitor daptor Plate (2 in. round capacitor) E E E Capacitor daptor Plate (2 in. X 1-1/4 in. oval capacitor) E E E Page 6 of URM-

7 MODEL URM- URM- URM- URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION FN GROUP 16 Stk Fan Motor Stk Fan Blade Capacitor - Compressor/Fan See Compressor Group MODEL URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION C C C FN GROUP 16 Stk Fan Motor Stk Fan Blade Stk Capacitor - Fan Motor MODEL No. Notes TECHNICL VRITION COOLING CPCITY URM- 018 URM- 024 BLOWER GROUP Stk Blower ssembly (Includes items 36-41) S S S S S S Stk Capacitor - Blower Motor a Housing S S S S S S b Cut-Off E E E E E E Stk Blower Motor Motor Mounting Bracket ssembly (includes items 40a, 40b) S S S S S S a Motor rm ssembly (3) b Motor Band Stk Blower Wheel URM- 030 URM- 036 URM- 042 URM- 048 Page 7 of URM-

8 MODEL No. Notes TECHNICL VRITION COOLING CPCITY URM- 018 COIL GROUP CONDENSER COIL: 52 Stk Condenser Coil S S S S S S Distributor - 1/2 in. to 3/8 in. two way N/ N/ N/ Distributor - 3/8 in. to 3/8 in. three way N/ N/ N/ N/ N/ Distributor - 3/8 in. to 3/8 in. four way N/ N/ N/ N/ Distributor - 5/8 in. to 3/8 in. four way N/ N/ N/ N/ ccess Valve Body (2) ccess Valve Core (2) ccess Valve Cap (2) EVPORTOR COIL: 53 Drain Trap (ttached to Drain Pan) Stk Evaporator Coil S S S S S S Drain Pan Grommet Stk Drain Pan S S S S S S uxiliary Drain Pipe E E E E E E Evaporator Coil ir Baffle (4) N/ N/ N/ N/ E E Distributor (w/o Piston) S Stk Flowcheck Piston Kit N/ Stk TXV Condensate Barrier E E E E E E URM- 024 URM- 030 URM- 036 URM- 042 URM- 048 MODEL URM- URM- URM- URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION COMPRESSOR GROUP Compressor ID: Stk Compressor S S S S S S 37 Stk Capacitor - Compressor/Fan Grommet dapter - Reducing Coupling N/ N/ N/ N/ Compressor ID: Stk Compressor S S 37 Stk Capacitor - Compressor/Fan Grommet dapter - Reducing Coupling N/ N/ N/ N/ N/ Compressor ID: Stk Compressor S Stk Capacitor - Compressor/Fan Grommet MODEL URM- URM- URM- TECHNICL VRITION No. Notes COOLING CPCITY ELECTRICL DESIGNTION C C C COMPRESSOR GROUP Compressor ID: Stk Compressor S S S dapter - Reducing Coupling N/ N/ Grommet Compressor ID: Stk Compressor S S S dapter - Reducing Coupling N/ Grommet Page 8 of URM-

9 MODEL No. Notes TECHNICL VRITION HETING CPCITY HET EXCHNGER / BURNER GROUP 24 Stk Heat Exchanger - Includes Center Panel and Turbulators S S S S a Turbulators E E E E (2) (3) (4) (5) 24b NOX Insert ssembly (2) (3) (4) (5) 24c Lower Burner Shield (NOX models) E E E E Collector Box Gasket d Collector Box E E E E Stk Limit Control (On Blower Shelf) - Cooling Capacity 018/ Stk Limit Control (On Blower Shelf) - Cooling Capacity Burner Floor See Panels Group 42 Radiation Shield E E E E Stk Burner Tube w/shield (2) (3) (4) (5) Stk,3 One-piece Burner Retrofit Kit - See Note 3 S S S S Burner Support Bracket (2) E E E E Stk Manifold (w/o Orifices) Burner Orifice - Natural Gas See Orifice Selection Chart 47 Burner Orifice - LP See Orifice Selection Chart 47 Number of Orifices (2) (3) (4) (5) 48 Stk Flame Sensor Stk Ignitor w/cable Burner Support - (Holds Burners between the Burner Support Brackets) E E E E Stk,1 Limit - Manual Reset (Burner Compartment) - Before F2501 (See Note) Stk,1 Limit - Manual Reset (Burner Compartment) - fter F2501 (See Note) Square Head Plug - (Used on Manifold to plug extra holes) (3) (2) (1) N/ URM- 04 URM- 06 URM- 08 URM- 10 MODEL No. Notes TECHNICL VRITION GS CODE GS CONTROLS Stk Furnace Control Board Stk Fan Board Stk Gas Valve - Natural Gas Stk,2 Gas Valve - LP See Note 2 See Note 2 See Note 2 See Note 2 Stk LP Conversion Kit EP-85H EP-85H EP-84W EP-84W URM- 1 URM- 1C URM- 1D URM- 1F MODEL No. Notes TECHNICL VRITION GS CODE URM- 1TF GS CONTROLS Stk Furnace Control Board Stk Fan Board Stk Gas Valve - Natural Gas Stk,2 Gas Valve - LP See Note 2 Stk LP Conversion Kit EP-84W MODEL No. Notes TECHNICL VRITION GS CODE GS CONTROLS 34 Stk Integrated Furnace Control Board (IFC) Stk Gas Valve - Natural Gas Stk,2 Gas Valve - LP See Note 2 See Note 2 See Note 2 See Note 2 Stk LP Conversion Kit EP-85H EP-84W EP-84W EP-84W URM- 1R URM- 1S URM- 1X URM- 2 MODEL No. Notes TECHNICL VRITION GS CODE URM- 2G GS CONTROLS 34 Stk Integrated Furnace Control Board (IFC) Stk Gas Valve - Natural Gas Stk,2 Gas Valve - LP See Note 2 Stk LP Conversion Kit EP-85H Page 9 of URM-

10 MODEL No. Notes TECHNICL VRITION COOLING CPCITY Economizer - 3 Position Economizer - Modulating Fresh ir Damper - 3 Position Fresh ir Damper - Fixed 35% Low mbient Control High Pressure Control Low Pressure Control OPTIONS ND CCESORIES URM- LL RXRE-C30 RXRD-CM10 RXRF-FB1 RXRF-F1 RXRZ-18 RXB-02 RXC-02 Page 10 of URM-

11 PCKGE EQUIPMENT - ORIFICE SELECTION CHRT - NTURL GS CUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) ltitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CN B CUTION: This information is provided for replacement purposes only. Conversion for operation at High ltitude must be done using the kit specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is based on a Natural Gas heating value of 1075 BTU/cu. ft and a pressure setting of 3.5 in. water column. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of ft. Canadian High Elevation (ft.) Furnace Number ltitude Derated Country Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. Canada Canada 40,000 36, ,000 54, ,000 N/ N/ 80,000 72, ,000 N/ N/ 100,000 90, , , , , , , ,000 N/ N/ 210,000 N/ N/ 210,000 N/ N/ 225, , , , , , ,000 N/ N/ 290,000 N/ N/ 300, , ,000 N/ N/ 350, , , , PCKGE EQUIPMENT - ORIFICE SELECTION CHRT - LP CUTION: Selection of the correct LP Orifice requires the following information for the specific installation: 1) Furnace Input Rating (BTU/HR) 2) Number of Burners 2) ltitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CN B CUTION: This information is provided for replacement purposes only. Conversion to LP or for operation at High ltitude should be done using the kit(s) specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and CNB NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on a heating value of 2500 BTU/cu. ft. and an elevation of ft. Canadian High Elevation (ft.) Furnace Number ltitude Derated Country Input of Input Rating (BTU/HR) Burners (BTU/HR) U.S. U.S. U.S. U.S. Canada Canada 40,000 36, ,000 54, ,000 N/ N/ 80,000 72, ,000 N/ N/ 100,000 90, , , , , , , ,000 N/ N/ 210,000 N/ N/ 210,000 N/ N/ 225, , , , , , ,000 N/ N/ 290,000 N/ N/ 300, , ,000 N/ N/ 350, , , , Page 11 of URM-

12 Exploded View Page 12 of URM-

13 Control Box ssembly Page 13 of URM-

14 Blower ssembly Page 14 of URM-

15 Evaporator Coil ssembly Evaporator Coils Baffles Page 15 of URM-

16 Condenser Coil Group Page 16 of URM-

17 Heat Exchanger ssembly Page 17 of URM-

18 Burner ssembly Page 18 of URM-

19 NOTES Stk It is recommended that stock be maintained for this part. N/ Not pplicable 1 The Flame Roll-Out Limit Control on these models was changed on the date code shown to a higher-rated switch. This change was made in order to reduce nuisance tripping. It is recommended that the higher-rated switch be used for replacement. 2 Order Gas Valve for Natural Gas along with LP Conversion Kit. 3 This kit includes all necessary items to retrofit units using individual burner tubes with the later one-piece burner design. P.O. Box Fort Smith, R

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List Form No. 92-42800- This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Package ir Conditioners Table of Contents

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List 19-ugust-2015 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 80% Gas Furnaces Table of Contents odel xplanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. - Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800--.pdf for the current revision. Package Air onditioners Table of ontents Model Explanation...................................................................................................................

More information

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE

More information

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.

More information

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16

More information

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41

More information

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001

More information

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001

More information

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11

More information

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM

More information

PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)

PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)

More information

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31

More information

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13

More information

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG

More information

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35

More information

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE

More information

UHKA. Air Handlers. Parts List 02-June-2015

UHKA. Air Handlers. Parts List 02-June-2015 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Air Handlers Table of Contents Model Explanation...................................................................................................................

More information

GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)

GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING

More information

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

RH1P. Air Handlers. Parts List 09-May-2014

RH1P. Air Handlers. Parts List 09-May-2014 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-800-.pdf for the current revision. Air Handlers Table of Contents Model Explanation...................................................................................................................

More information

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8

More information

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,

More information

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF A Series 15 SEER Models REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper repair

More information

Spare Parts Catalogue MV1006

Spare Parts Catalogue MV1006 Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO

More information

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14

More information

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44

More information

FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)

FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) www.source1parts.com HVAC SERVICE PARTS Supersedes: 650.75-RP1U (1199) 035-17790-001 Rev. A (1102) 1 of 8 13 5 9 8 61 6 10 4 2 11 12 7 3 16 1 14 15

More information

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS) See unit nameplate for manufacturer and address. 506003 01 5/2009 Supersedes 1/2008 TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS) TGA090, 102, 120, 150, TGA120 SHOWN (7

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,

More information

PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES

PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.

More information

GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal

GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal

More information

FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)

FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)

2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) 2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure

More information

Rheem Classic Plus Series Multi position Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Multi position Gas Furnaces R95T- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency

More information

2 STAGE UPFLOW NATURAL GAS FURNACES (94+)

2 STAGE UPFLOW NATURAL GAS FURNACES (94+) 2 STAGE UPFLOW NATURAL GAS FURNACES (94+) HVAC SERVICE PARTS Supersedes: 035-17482-000 Rev. E (1102) 035-17482-000 Rev. F (0304) 1 of 8 Figure 1: 2-STAGE UPFLOW NATURAL GAS FURNACES (94+) P1XUB12N05501

More information

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above) FORM NO. G66-480 Supersedes Form No. G66-480 Rev. 0 90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel

More information

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS) See unit nameplate for manufacturer and address. 504,875M 1/2006 Supersedes 1/2004 LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

More information

Ruud Achiever Series Multi position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: S96VA Multi-Position Gas Furnaces FORM NO. GSC-540 REV. 5 Sure Comfort S96VA 96% A.F.U.E. Two-Stage Variable Speed Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: 181-401, 182-400 CATALOG NO. 9300.203 Effective: 01-01-19 Replaces: 06-15-16 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 182, 260, 330, 400 ATMOSPHERIC 181, 261, 331, 401 LOW NOx MODEL

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Rheem Classic Series Downflow/ Horizontal Gas Furnaces Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

UPFLOW NATURAL GAS FURNACES - 90%

UPFLOW NATURAL GAS FURNACES - 90% Y W R G C UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-17489-000 Rev. C (1201) 035-17489-000 Rev. D (302) 1 of 8 13 5 8 10 4 2 9 6 14 11 1 COOL HEAT CIR 12

More information

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B E N G I N E E R I N G D T G S F U R N C E S ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 June 20 Supersedes May 20 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

Effective october 14, 2014

Effective october 14, 2014 COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET DS-07 COMPRESSORS 1 1 Compressor, H20J403DBLA 015-03652-001 2 - - 1 1 Compressor, H20J403DBEA 015-03682-001-2 - 1 1 Compressor,

More information

Replacement Parts List For Models COS-20G

Replacement Parts List For Models COS-20G Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Models: Contents. Cabinet Components. Functional Components  Exploded View... 3  Usage List Control Panel. Blower Assembly REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA0, WA7 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

C-Spa XI Models

C-Spa XI Models C-Spa XI Models. -. - HEATER REPLACEMENT PARTS Parts Diagram 9 9 6 0 3 6 8 3 0 8 6 3 HAYWARD C-Spa XI Models. -. - HEATER REPLACEMENT PARTS Parts Listing Ref. No. Part No. Description Ref. No. Part No.

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace R802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) EXTERIOR SHEET METAL (OUTER PANELS) 1 COMPAC AVP72/AVPA72 PARTS LIST, 03/09 EXTERIOR SHEET METAL (OUTER PANELS) AVP72AC AVPA72AC 1 Panel, Back (Galvanized) M/04443SP 2 Right Side Panel, ComPac II M/04465XXSP

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/

More information

ML 1 80 UH 070 X E 36 B

ML 1 80 UH 070 X E 36 B PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces Gas Furnaces Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces R98V- Series 98% A.F.U.E. Input Rates from 60 to 115 kbtu [11.57 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] All Models except R96VA085

More information

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-498 Supersedes Form No. P66-765 Rev. 3 90TS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 February 208 Supersedes November 207 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] All Models except R96VA085

More information

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

MARVAIR MODPAC TM AIR CONDITIONERS MODELS AVPA EXPLODED VIEW PARTS ID

MARVAIR MODPAC TM AIR CONDITIONERS MODELS AVPA EXPLODED VIEW PARTS ID MODELS AVPA -8-0 EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 0 8 5 AVAP AVPA8 AVPA0 Panel, Back (Galvanized) M/0-SP Door, Front Top M/0-XXSP Door, Front Bottom M/080-XXSP Fresh Air Hood

More information

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICTIONS GS FURNCES EL80UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 20660 February 208 Supersedes January 208 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information