Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017
|
|
- Mae McCarthy
- 6 years ago
- Views:
Transcription
1 Replacement Parts List No Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call or visit
2 Contents Parts List Revision History Nomenclature Serial Number... 5 Model Number Electrical Legend... 7 Blower Fan Assembly... 8 Refrigeration Circuit- Compressor, Condenser, Evaporator, Switch & Valves Diagrams... 9 Components Control Box MicroTech III Controls MTIII Control Board Label Location Field Installed Accessories Critical Parts List... CPL1 WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 2
3 Parts List Revision History Rev. Date Description NEW 05/09 NEW A 10/09 Page 22- Add retrofit kit p/n and retrofit kit p/n B 07/10 Title page- Add unit size 007. Change Nomenclature to Code Index AAA. Page 6- Delete Ball Valves and Motorized Valves chart and add new chart. Page 8- Replace page with revised charts. Pages Add footnote (*) for color-specific p/ns. Pages Add unit size 007 p/ns. Page 22- Add new descriptions for p/ns , , , Add p/ns and Change Bub #750 to Bub #140. Pages 23, 25 Add size 007 p/ns. Add control box and stand off descriptions. Add Conn H1-9. C 03/12 Page 6- Change Ball Valve, 10 pack p/n to Add Motorized Valve Kits p/ns , , Add Motorized Valve Wire Harness Kit p/n Page 12-Ref#100 Add Antique Ivory p/n for Low Sill. Ref#145 Add Antique Ivory p/n for High & Low Sill. Ref#160 Add Antique Ivory p/n for High & Low Sill. Ref#170 Add Antique Ivory p/n for High & Low Sill. Ref#195 Add Antique Ivory p/n for High & Low Sill. Page 13- Ref #565 Change panel-front p/n to Page 25- Ref#53 Added sensor,suction line temperature (SLTS) p/n Ref #24 Change Standoff PC Board p/n to & Qty to 6. Change Standoff Edge-holder p/n to CPL1- Add Critical Parts List. D 04/12 Brand Change. Page 4- Update serial Number to current format. Page 16- Change 208/230V motor p/n to Change 265V motor p/n to & 115V motor p/n to CPL1- Change 208/230V motor p/n to Change motor p/ns. E 04/13 All Pages updated CS6, dwgs and numerous changes done(sheet metal parts deleted). Pages 4-5 Nomenclature changes- C05= F; C11=Y(1st digit); C24= G-N, Y & 1-4 added. Page 6- Add page for Electrical Legend. Pages 7-9 Field Installed Accessories- Delete Motorized Valve p/n Add numerous Thermostats, Sensors and Wall Plate (p/ns from IM/OM). Add Consle Damper, Comm. Module Kit and Subbase Kit. Add page & arrange to fit. Pages Delete all sheet metal for cabinet and chassis components. Footnote 1 added to Controls (pg18) to contact McQuay Parts for sheet metal p/ns. Ref #205 Change Scroll fan p/n to Page 12- Add Digrams for Refrigeration Circuit. Page 13- Change sleeve p/n to CPL1- Change Scroll Fan p/n to Change Rev Valve p/n to and Solenoid p/n to F 09/13 Page 8- Add right hand subbase kit p/ns & G 11/13 Rebrand Daikin. Page 25- Change MTIII I/O Exp p/n to Change MTIII LonWorks p/n to and BACnet p/n to CPL1- Change MTIII I/O Exp, MTIII LonWorks & BACnet. H 07/14 Page 20- Change High Pressure Switch p/n to I 03/05 Delete cabinet & chassis sheet metal. Numerous changes. Page 9, Delete OA Damper, Basic Unit Layout, sheet metal cabinet/chassis components. Page 10- Add motor capacitor p/ns & Add Cabinet/Chassis Components and footnote 1. Page 11- Change compressor mounting detail drawing. Change Ref#s for Line Weight, condenser, compressor, plug assy, pressure valve & line weight. Page 12- Change Overload p/n to Pages Delete & combine controls pages Add MTIII diagrams for V & 265V. Change Capacitor, relay DPST, SLTS & transformer p/ns. Pages Field Installed Accessories moved from pages 7-9. CPL1- Delete comm cards & expansion valves. Add SLTS. J 10/15 Update to Daikin Format. Page 13- Add I/O Board until 08/12 p/n Add footnote for MTIII label location. Page 14- Add MTIII Controls Label Location table and footnote. CPL1- Update to Daikin Format. Daikin Applied,13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 3
4 Parts List Revision History Rev. Date Description K 04/16 Title Page add Design 2 for V. Numerous changes. Page 5- Code 2, Add Design 2= 2 (Size V only). Page 8- Change indoor motor 115V p/n to fan assy, rework p/n Change motor V p/n to fan assy, rework p/n Change motor 265V motor p/n to fan assy, rework p/n Page 10- Change mount-vib p/n to Page 13- Add LUI keypad thermostat programmable p/n & thermistor p/n for TStat Retrofit Kits p/ns & Page Add numerous updates to field Installed accessories. CPL1- Change motors p/n to fan assy, rework p/ns CPL2-Add Design 2 (unit size 009, 265V). L 12/16 Page 8- Change Ref # 280 fan p/n to Ref#100 Motors- Add footnote #2. Change motor 115V rework p/n to p/n Change motor V rework p/n to p/n Change motor 265V rework p/n to p/n CPL1-CPL2- Update motors. M 11/17 A new RPL was created for Design 2 components. Page 11- Change High Pressure Switch p/n to Change reversing valve p/n to CPL1- Update revision. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 4
5 Nomenclature Plant Identification AUB = Auburn SLP= San Luis Potosi U= Unit Serial Number AUB U Year of Manufacture 09= = 2010 etc. Serial Number (build sequence) Week of Manufacture Model Number WMHC C E H B T 01 F2 E C Y YY Code L RPL YYY YYY A D YYY H S Y Code Code 01= Unit Type W= Water Source Heat Pump Code 02= Product Identifier MHC= Wall Mounted Console WSHP, Standard Range MHW= Wall Mounted Console WSHP, Geothermal Range Code 03= Design Series 1= Design 1 Code 04= Unit Size 007= 7000 BtuH Nominal Cooling 009= 9000 BtuH Nominal Cooling 012= BtuH Nominal Cooling Code 05= Controls B= MicroTech III Unit Controller C= MicroTech III Unit Controller w/ LonWorks D= MicroTech III Unit Controller w/ BACnet F= MicroTech III Unit Controller w/ BACnet-WSHP System Code 06= Voltage A= E= /60/1 J= Code 07= Cabinet Height H= High Sill L= Low Sill Code 08= Return Air B= Bottom Return Air (High Sill) F= Front Return Air (Low Sill) Code 09= Discharge Air T= Top Discharge Code 10= Blower Motor 01= Standard Code 11= Cabinet Type /Discharge Grille 1st Digit- Cabinet Type A= Flat Top w/12 Extended End Pocket (High Sill) B= Slope Top w/12 Extended End Pocket (High Sill) F= Flat Top S= Slope Top 2nd Digit- Discharge Grille C= Chassis only (no extended end pocket) 1= Bargrille (Anodized Extruded Aluminum) 2= Standard Stamped Louver 3= Multi-Directional Grille 4= Double-Deflection Adjustable Grille (Plastic) Code 12= Cabinet Construction Type A= Fiberglass Insul w/1 Filter Rack- Std E= Indoor Air Quality (IAQ) w/1 Filter RacK Code 13= Water to Refrigerant Heat Exchanger C= Copper Inner Tube/ Steel Outer Tube S= Cupro Nickel Inner Tube/ Steel Outer Tube Code 14= Heating Options 2= 2.5 kw Electric Heat Y= None Code 15= Dehumidification YY= None Code 16= Piping Hand L= Left Hand R= Right Hand Continued on the next page. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 5
6 Nomenclature Continued Code 17= Thermostat Control YYY= None R N L Options L= Low Limit Control M= Low Limit Control & Unit-mounted NSB Override Switch P= NSB Override Switch R= Remote Sensor Y= None Programmability N= Non- Programmable P= 7- Day Programmable w/lcd Display Y= None Controls R= Remote S= Wall Mounted Space Sensor w/nsb Override U= Unit Mounted T stat w/lcd Display W= Wall Mounted T stat w/fan Speed Switch Y= None Code 18= Always YYY Code 19= Always YYY Code 20= Refrigerant A= R410a Code 21= Power Connection C= Unit Mounted 20A Plug & Cord D= Unit Mounted 20A Plug & Cord w/ 15A Fused Disconnect Sw E= Unit Mounted 20A Plug & Cord w/ Non-Fused Disconnect Sw Y= None Code 22= Cabinet Electrical 75V= 75VA Transformer YYY= None Code 23= Water Flow Control H= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. P= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. & Supply, Return, Bypass Hand Valves & Measureflow Devices R= ½ Supply, Return & Bypass Valves Only W= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. & Supply, Return & Bypass Hand Valves Y= None Code 24= Color Y= None Cabinet Grille Subbase S= Antique Ivory Oxford Brown Oxford Brown T= Antique Ivory Antique Ivory Oxford Brown B= Antique Ivory Antique Ivory Antique Ivory D= Cupola White Oxford Brown Oxford Brown P= Cupola White Cupola White Oxford Brown E= Cupola White Cupola White Cupola White G= Off White Oxford Brown Oxford Brown F= Off White Off White Oxford Brown H= Off White Off White Off White K= Putty Beige Oxford Brown Oxford Brown R= Putty Beige Putty Beige Oxford Brown L= Putty Beige Putty Beige Putty Beige V= Soft Grey Oxford Brown Oxford Brown J= Soft Grey Soft Grey Oxford Brown N= Soft Grey Soft Grey Soft Grey Cabinet Subbase 1= Antique Ivory Oxford Brown 2= Antique Ivory Antique Ivory 3= Cupola White Oxford Brown 4= Cupola White Cupola White Code 25= Outside Air Y= None Code 26= Agency Type Code 27= Packaging Code 28= Extended Warranty Code 29= Product Style 1= Style 1 WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 6
7 Electrical Legend Schematic Sym. BNM C1 C2 CC CM COS CR DAT DPG EWT FHS FSR FSS HP IOEXP LED1 LED2 LWT MIII OVL R1 R2 RAT RV SLTS T1 TB1 UMT X1 Description BACnet Module Capacitor- Compressor Capacitor- Fan Contactor- Compressor Compressor Motor Sensor- Condensate Overflow Relay- Compressor Sensor- Discharge Air Drain Pan Ground Sensor- Entering Water Relay- Fan High Speed Relay- Fan Speed Switch- Fan Speed Switch- High Pressure I/O Expansion Board/Harness LED Annunciator/Harness LED Annunciator/Harness Sensor- Leaving Waters MicroTech III Main Board Compressor Overload Protector Relay- Fan Motor Relay- Electric Heat Sensor- Room Air Valve- Reversing Sensor- Suction Line Temperature EG2UCP Terminal Strip Power Terminal Block Thermostat- Unit Mounted Transformer WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 7
8 Blower Fan Assembly Motor, Wheel, Fan Housing Cabinet/Chassis components Ref. No. Part Description Part Number / / / Motor Motor Motor N/S Capacitor, 4.0 MFD 370V Capacitor, 1.5 MFD 370V Bracket, Motor Mount Fan Housing, Scroll Fan, Tangential Bearing Plate N/S Drain Pan N/S Cabinet/Chassis components N/S= Not Shown. 1 Please contact Daikin Applied with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Each motor has six (6) terminal pins p/n and one (1) Plug Housing p/n 4EFA9389. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 8
9 Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Diagrams Evaporator Coil/ TXV Detail Condenser Detail Compressor 137 Reversing Valve Piping Coremax Valve Assy Compressor Mounting Detail TXV Bulb Coremax Valve Assembly Detail Low Temperature Sensor Bulb 151A 151B 151C WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 9
10 Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components Unit Size Ref Part Part No. Description Number 57 Sleeve, Compressor Mount Nut, Compressor Mount (until 11/15) Nut, Compressor Mount (11/15 & later) Grommet, Compressor Mount Compressor 7000 BTUH Compressor 7000 BTUH Compressor 7000 BTUH Compressor 8000 BTUH Compressor 8000 BTUH Compressor 8000 BTUH Compressor BTUH Compressor BTUH Compressor BTUH N/S Overload, Compressor until 3/ Overload, Compressor 3/13 & later Overload, Compressor Overload, Compressor Overload, Compressor Overload, Compressor Overload, Compressor Overload, Compressor Overload, Compressor Overload, Compressor N/S Plate, Compressor Plate, Compressor Condenser- Coax Copper Inner Tube Condenser- Coax Copper Inner Tube Condenser- Coax Copper Inner Tube Condenser- Coax CUNI Inner Tube Condenser- Coax CUNI Inner Tube Condenser- Coax CUNI Inner Tube Evaporator Coil until 02/ Evaporator Coil 02/10 & later Evaporator Coil, LH until 02/ Evaporator Coil, LH 02/10 to 10/ Evaporator Coil, LH 10/14 & later Evaporator Coil, RH until 02/ Evaporator Coil, RH 02/10 to 10/ Evaporator Coil, RH 10/14 & later N/S= Not Shown. 208/230/60/1 208/230/60/ /230/60/1 Continued on next page. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 10
11 Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components, Continued Unit Size Ref Part Part No. Description Number 110 Reversing Valve until 3/ Reversing Valve 3/11 to 11/ Reversing Valve 11/17 & later Reversing Valve until 3/ Reversing Valve 3/11 to 5/ Reversing Valve 5/14 & later N/S Solenoid-Reversing Valve until 3/ Solenoid-Reversing Valve 3/11 to 5/ Solenoid-Reversing Valve 5/14 to 11/ Solenoid-Reversing Valve 11/17 & later Solenoid-Reversing Valve 5/14 & later High Pressure Switch until 7/ High Pressure Switch 7/11 to 03/ High Pressure Switch 03/16 & later A Seat, Fitting B Core, Valve C Cap, Valve Fusible Plug Assy Plug Only 283 F Valve, Expansion- 1/2 Ton Valve, Expansion- 3/4 Ton Valve, Expansion- 1 Ton Line Weight Line Weight Line Weight N/S Electric Heater- 2.5KW C14= N/S= Not Shown. 208/230/60/1 208/230/60/ /230/60/1 WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 11
12 Control Box MicroTech III Controls Components V Units 265V Units Ref. No. Part Description Part Number /60/ /60/ /60/1 N/S Bracket, Capacitor N/S Capacitor, Compressor, 50MFD 440V (until 04/12) Capacitor, Compressor, 50MFD 440V (04/12 & later) Capacitor, Compressor, 20MFD 440V (until 04/12) Capacitor, Compressor, 20MFD 440V (until 04/12) Capacitor, Compressor, 20MFD 440V (04/12 & later) Capacitor, Compressor, 55MFD 440V (until 04/12) Capacitor, Compressor, 55MFD 440V (04/12 & later) Capacitor, Compressor, 25MFD 440V (until 04/12) Capacitor, Compressor, 25MFD 440V (04/12 & later) Capacitor, Compressor, 30MFD 440V (until 04/12) Capacitor, Compressor, 30MFD 440V (04/12 & later) Main Controller, MicroTech III * N/S I/O Expansion Board Assy (until 08/12) * I/O Expansion Board Assy (08/12 & later) * LED Annunciator Assy N/S Stand Off- PC Board Stand Off- Comm. Card Relay, Fan, 24V, 3PDT N/S= Not shown on diagram. * When ordering this board, please provide the software part number printed on the board s label. See photo on Control Board Label Locations page. Continued on next page. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 12
13 Control Box MicroTech III Controls Components, Continued Ref. No. Part Description Part Number /60/ /60/ /60/1 200 Relay, 24V, 30A (until 04/13) Relay, 24V, 30A (04/13 & later) Transformer, 50VA (until 04/11) Transformer, 50VA (04/11 & later) Transformer, 50VA (until 04/11) Transformer, 50VA (04/11 & later) Transformer, 50VA (until 04/11) Transformer, 50VA (04/11 & later) Transformer, 75VA (until 04/11) Transformer, 75VA (04/11 & later) Transformer, 75VA (until 04/11) Transformer, 75VA (04/11 & later) Transformer, 75VA (until 04/11) Transformer, 75VA (04/11 & later) N/S Rocker Switch N/S Switch, Momentary, N.O TStat Retrofit Kit, 7-Day Programmable, Unit Mnt LUI Keypad Thermostat Programmable Thermistor N/S TStat Retrofit Kit, Non-Programmable, Unit Mnt LUI Keypad Thermostat Programmable Thermistor N/S Control Temperature, Low Limit, +48 /+54 F Control Temperature, Low Limit, +28 /+38 F N/S Suction Line Temp (SLT) N/S Air Temp Sensor (DAT) N/S Water Temp Sensor (LWT) N/S= Not shown on diagram. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 13
14 Control Box MicroTech III Controls MTIII Control Board Label Locations Label Label Label Label NOTE: When ordering the control board, please provide the software part number printed on the board s label. See above for label locations. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 14
15 Field Installed Accessories Filters Description 12 pack Part Number Filter X High Sill Units Filter X Low Sill Units Ball Valves, Motorized Valves & Relays Description Part Number Ball Valve, 1/2 (Box of 2) Ball Valve, 1/2 (Box of 10) Motorized Valve Kit 1/2 2-Way Valve, Normally Closed (NC), 25 PSi Close-Off Pressure Motorized Valve Kit 1/2 2-Way Valve, Normally Closed (NC), 30 PSi Close-Off Pressure Motorized Valve Kit 1/2 2-Way Valve, Normally Open (NO), 25 PSi Close-Off Pressure MicroTech III, H-8 Output Wire Harness Assy MicroTech III to Mark IV Daisy Chain Adaptation for E and U Thermostats & Sensors Description Part Number Remote ENF Temp Sensor for , Wall, Stat- AC/DC, ACO, 7 Day Programmable, 2 Heat/2 Cool with Wall Plate Wall, Stat- AC/DC, ACO, Non-Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate Wall Sensor for & Wireless Thermostats Description Part Number TStat, Wireless, 7 Day Programmable, Hi/Low Fan Speed TStat, Wireless, Non-Programmable, Hi/Low Fan Speed Field Programming Transfer Cable Description Part Number Field Programming Transfer Cable MicroTech III Communication Modules Description Part Number LonWorks Comm Module BacNet Comm Module * Kit includes comm module card, sensors, mounting tabs, and IM. Continued on next page. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 15
16 Field Installed Accessories Continued Hoses Description Specification Part Number Hose Assy, Fire Rated Condensate 3/4" NPT X 2' /4" NPT X 3' Hose Assy, Fire Rated Supply/Return 1/2" NPT X /2" NPT X /2 NPT X /2 NPT X Hose Assy, Plastic Condensate 3/4" NPT X 30" /4" NPT X 36" Outdoor Air Dampers for High Sill Units* Description Part Number Manual O.A. Damper Kit Motorized O.A. Damper Kit, 24V * See IM Subbase Kit Description Right Hand Left hand 3.5 Hi-Sill Hi-Sill Low-Sill Straight Adapter & Elbow Kits Description Part Number 90 Elbow Kit 2 Pack Elbow Kit 10 Pack Elbow Kit 20 Pack Elbow Only Straight Adapter Kit 2 Pack Straight Adapter Kit 10 Pack Straight Adapter Kit 20 Pack Adapter Only-.625 x.500 FPT Fused Disconnect Kit Description Kit Fuse P/N Fuse, 265V, 7A EHG7750 Fuse, 265V, 10A EHG7795 Fuse, 208/230V, 7A EHG7750 Fuse, 208/230V, 10A EHG7795 Fuse, 115V, 15A Fuse, 115V, 20A Continued on next page. WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 16
17 Field Installed Accessories Continued MicroTech III Temperature Sensors Part Kit Tenant Set Point Status LED Fan & Number Override Adjustment Mode Switches Yes No No No Yes 55 to 95 F (12 to 35 C) Yes Yes Yes -3 to +3 F (-1.5 to 1.5 C) No Yes Note: Can only be used in conjunction with a Communication (Comm.) card. See OM 931 for required jumper settings. Description Part Number ** Multiple Unit Control Panel: Allows a master unit controlled by a T'Stat, to operate up to 3 secondary units Not Recommeended for use with a Boilerless System Kit Boilerless System Kit with I/O Expansion Board Boilerless System Kit without I/O Expansion Board ** Kit components listed below MicroTech III Unit Control Accessories Multiple Unit Control Panel Kit Ref. Description Part Qty. No. Number 310 Cover- Control Box Circuit Board Stand Off- Circuit Board Box WSHP, WMHC/WMHW , Design 1 Rev. M 11/17 RPL / Page 17
18 Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Enfinity WSHP Console McQuay Enfinity WSHP Console WMHC, WMHW 007, 009, 012 Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL Compressor Compressor Compressor /60/ Compressor Compressor Compressor /60/ Compressor Compressor Compressor /60/ Compressor Blower Fan Assy Motor ALL Motor ALL /60/ Motor ALL Fan Housing & Wheel Fan Housing ALL N/A Wheel, Tangential ALL N/A Sensor Line Temp Sensor (SLTS) ALL N/A Air Temp Sensor (DAT, RAT) ALL N/A Water Temp Sensor (LWT) ALL N/A Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To or Call PARTS Rev. M 11/2017 CPL Page 1 of 1
Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017
Replacement Parts List No. 700013100 Revision O 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018
Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017
Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationMcQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018
Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000
Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787
More informationMcQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)
Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design
More informationAAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016
Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationMcQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993
Replacement s List No. 55209100 Revision E 10/2015 McQuay Console Water Source Heat Pump WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor,
More informationMcQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationMcQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995
Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationMcQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)
Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationMcQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)
Replacement Parts List No. 057117200 Revision G 08/2016 McQuay Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E WCDD, WCDE, WCMG 019-060 Design A (1) WCDD, WCDE 019-060 Design B (2) To find
More informationDaikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017
Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationMcQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994
Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988
Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin
More informationMcQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018
Replacement Parts List No. 700051500 Revision D 08/2018 McQuay Self-Contained Unit Ventilator UAZQ, UAZR, UAZU 024-054 Design G (7) To find your Daikin Applied parts distributor, call 1-800-377-2787 or
More informationEnfinity Console Water Source Heat Pumps 1/2 to 1½ Ton
Enfinity Console Water Source Heat Pumps 1/2 to 1½ Ton R-410A Models MHC Standard Range & MHW Extended Range Unit Sizes 007-018 Catalog 1104-11 Contents Model Nomenclature... 3 AHRI Performance Data....
More informationMcQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008
Replacement Parts List No. 055237900 Revision R 12/2017 McQuay Seasonmaker ThinLine Horizontal Fan Coil TSH, TSC 031-121 Vintage F FTSH, FTSC 03-12 Designs A(1), B(2) Last Manufactured: 2008 To find your
More informationAir Cooled Scroll Compressor Condensing Unit
Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature
More informationCCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW
Operation & Maintenance Manual OM 931-6 Group: WSHP Part Number: 910157590 Date: September 2014 MicroTech III Unit Controller for Water Source Heat Pump Units Used with Enfinity Models CCH/CCW, VFC/VFW,
More informationConsole Water Source Heat Pumps
Installation & Maintenance Data IM 985 Group: WSHP Part Number: 107225604 Date: April 2009 Console Water Source Heat Pumps R-410A Models MHC Standard Range & MHW Geothermal Range Flat Top & Slope Top Unit
More informationConsole Water Source Heat Pumps
Installation & Maintenance Data IM 985-2 Group: WSHP Part Number: 669479302 Date: November 2011 Console Water Source Heat Pumps R-410A Models MHC Standard Range & MHW Geothermal Range Flat Top & Slope
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationDaikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3
Replacement Parts List No. 70002700 Revision G 02/204 Daikin McQuay Applied PTAC Air Conditioner and Heat Pump PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF 007-07 Design 3 To find your Daikin Applied parts
More informationMcQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1
Replacement Parts List No. 700008800 Revision M 02/2014 McQuay Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF 007-017 PDHP, PDHA, PDHE, PDHF 007-015 Design 1 To find your Daikin
More informationMcQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016
Replacement Parts List No. 7000900 Revision E 04/06 McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage A To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationDaikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017
Replacement Parts List No. 7000800 Revision F /07 Daikin McQuay Templifier Scroll Compressor Water Heater TGZ 040-90 Vintage B To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
More informationClimate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982
Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call
More informationMcQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978
Replacement Parts List No. 055224800 Revision C 10/2017 McQuay Aircon Air Cooled Condenser AMB, APB 020-140 AMD, APD 008-030 Vintage A Last Manufacture: 1978 To find your Daikin Applied parts distributor,
More informationMcQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007
Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied
More informationMcQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998
Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E
Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,
More informationMcQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018
Replacement Parts List No. 700014900 Revision J 02/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 020, 025 Vintage E To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationMcQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012
Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More informationMcQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)
Replacement Parts List No. 700022700 Revision H 02/208 McQuay Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV 024-054 Designs D (4), E (5) To find your Daikin
More informationInstallation and Maintenance Manual OM
Installation and Maintenance Manual OM 1149-3 Group: WSHP Document PN: 910208203 Date: April 2017 MicroTech III SmartSource Unit Controller with I/O Expansion Module for Single and Two Stage Water Source
More informationMcQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018
Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-(
More information(EE1500, EE2000, EE2500, EE3000)
EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor
More informationSpare Parts Catalogue MV1006
Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO
More informationEngineered for flexibility and performance
Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant Vertical Models LVC Standard Range & LVW Geothermal Range Unit Sizes 072 290 (6 to 25 Tons) R-410A Refrigerant Catalog 1109-5 Engineered
More informationOperation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps
Operation and Maintenance Manual OM 239 Group: WSHP Document PN: 906530 Date: July 205 MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps Large Capacity
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER W0AA-A W0AA-B W0AA-C W0AA-D W0AA-F WAA-A WAA-B WAA-C WAA-D WAA-E WAA-F Models: W0AADA W0AADB W0AADC WAADA WAADB WAADC Contents Description
More informationCatalog Enfinity Large Horizontal Water Source Heat Pumps with R-410A Refrigerant
Catalog 1112-4 Enfinity Large Horizontal Water Source Heat Pumps with R-410A Refrigerant Horizontal Models CCH Standard Range & CCW Geothermal Range Unit Sizes 072 120 (6 to 10 Tons) R-410A Refrigerant
More informationCHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION
CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION PART NUMBER BY CAPACITY 9/12 15 18/24 30 36/42 48 1 1 FRONT PANEL W/LOUVER 550-373 550-373 550-374 550-374 550-388
More informationCU0415, CU0715 and CU0920 Service Parts
CU0, CU0 and CU00 Service Parts This is the illustrated parts list for the CU0, CU0 and CU00. The CUR0, CUR0 and CUR00 are - (0-0/0/) versions of the matching models. There are voltages, /0/, 0-0/0/ and
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL W0HA-A W0HA-B W0HA-C WALL MUNTED PACKAGED HEAT PUMP WHA-A WHA-B WHA-C Models: W0HADA W0HADB W0HADC WHADA WHADB WHADC Contents Description Page Cabinet Components Exploded View...
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGE AIR CONDITIONER Models: W7A W8A WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of
More informationApplied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat
Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More information1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA
PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air
More informationSCE170 SERVICE PARTS
This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in
More informationCatalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps
SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps GTH - Horizontal Ceiling GTV - Vertical Floor Unit Sizes 026 072 R-410A Refrigerant Catalog 1114-8 Contents Model Nomenclature... 4
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT WRV-S WRV-T Models: WLV-S WLV-T Contents Description Page Cabinet Components Right (Extreme Duty Door) Exploded View...
More informationtechnical guide Water-Cooled Self-Contained Units
technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................
More informationParts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-340MAJ, MWJ hoshizakiamerica.com Number: 71389 Issued: 10-23-2017 Revised: 6-12-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationRepair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationPARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG
PARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG 1900 Wellworth Ave. Jackson, MI 49203 www.heatcontroller.com 517-787-2100 01/07 Part # Compressors HR PARTS LIST (rev. A & B) Item Description
More informationDaikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)
Replacement Parts List No. 700026200 Revision E 05/2017 Daikin McQuay Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit AWS 400-550 Vintage B Unit Revision 0B (Code 62) To find your Daikin Applied
More informationDaikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A
Replacement Parts List No. 700014100 Revision P 05/2017 Daikin McQuay Pathfinder Air Cooled Chiller Screw Compressor Two Circuit AWS 150-405 Vintage A For units built after 8/1/11, contact Daikin Applied
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationEnfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant
Installation & Maintenance Data IM 1059-2 Group: WSHP Part Number: 669479102 Date: November 2011 Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant Vertical Models LVC Standard Range
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationWater Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL
Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationSpaceKeeper Console (SKC)
SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper
More informationWHIRLPOOL REFRIGERADOR GS2SHGXLQ01
CABINET, LITERATURE 1 CABINET, LITERATURE 1 LIT2220425 LITERATURE PARTS (Energy Label) 1 LIT2220699 LITERATURE PARTS (Owner`s Manual) 1 LIT2255381 LITERATURE PARTS (Service & Wiring Sheet) 1 LIT628370
More informationParts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationVertical V*B Series Fan Coil Technical Catalog
Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with
More informationUNIVERSAL 750 PRE-MIX DISPENSER
Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0 MODEL NO. xxx xxx Universal 0 of Control Code A Manual Part No. 00 -- Revised: -- ªIMI Cornelius Co., - Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0
More informationProduct Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons
Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationParts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1100MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71392 Issued: 12-12-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationProduct Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic
Product Data Aquazone 0RHE006-060 Water Source Heat Pumps Horizontal Unit 0 Hz, CE Mark R-407C 1.to13.7NominalkW(Cooling) 1.8 to 16. 8 Nominal kw (Heating) TM Copyright 2004 Carrier Corporation Single-Package
More information9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners
PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,
More informationREPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)
REPAIR PARTS LIST Model No.(s) REFRIGERATOR 106.51182112 (White) 106.51183112 (Stainless Steel) 106.51189112 (Black) The model number of your refrigerator is found on the serial plate located inside, on
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationCatalog SmartSource Compact Vertical Water Source Heat Pumps. Model GCV - Vertical Unit Sizes (1/2 thru 6 tons)
Catalog 1116-8 SmartSource Compact Vertical Water Source Heat Pumps Model GCV - Vertical Unit Sizes 007 070 (1/2 thru 6 tons) Contents Model Nomenclature... 3 AHRI Performance Data.... 4 Compact model
More informationWiring Diagrams DIAGRAM INDEX
50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationSCCG50 & SCCP50 Service Parts
SCCG0 & SCCP0 Service Parts This is the illustrated parts list for the SCCG0M and the SCCP0M Residential Ice Machines hen ordering a service part, always refer to the complete model number of the equipment
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationSERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305
SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains
More informationMARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)
EXTERIOR SHEET METAL (OUTER PANELS) 1 COMPAC AVP72/AVPA72 PARTS LIST, 03/09 EXTERIOR SHEET METAL (OUTER PANELS) AVP72AC AVPA72AC 1 Panel, Back (Galvanized) M/04443SP 2 Right Side Panel, ComPac II M/04465XXSP
More information15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING
SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant
More informationICEU 36 SPARE PARTS LIST REV. 07/2016
ICEU 36 ~ SPARE PARTS LIST REV. 07/2016 ICEU 36 1 UNIT PANELS UP TO S.N. 02594 2 UNIT PANELS FROM S.N. 02595 3 REFRIGERANT SYSTEM AIR COOLED UP TO S.N. 02413 4 REFRIGERANT SYSTEM AIR COOLED - FROM S.N.
More informationMaverick II Commercial Rooftop Systems 15 to 75 tons
Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for
More informationCMS1402 SERVICE PARTS
This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz