How To Make Lando Water Chillers? Leading the way of innovation. Here is the instruction to know more us how to

Size: px
Start display at page:

Download "How To Make Lando Water Chillers? Leading the way of innovation. Here is the instruction to know more us how to"

Transcription

1 How To Make Lando Water Chillers? Leading the way of innovation Here is the instruction to know more us how to make hydroponic water chillers, aquarium water chillers, industrial water chillers. 2014/1/8 1

2 . How To Make Lando Water Chillers? Specializing in water chillers, Shenzhen Lando Technology Industrial Co., Ltd has been a leader in producing hydroponic Water Chillers, Aquarium Water Chillers, Laser Industrial Water Chillers and Water Chilled Air Condition Here is the entire production process of Lando Water Chiller as follows: 1. The first thing that is done is to check the titanium tube. The tube is then cleaned, bent, and then welded into a coil shape. The tube is then placed into a barrel and a clamp on the titanium tube is placed and it is tested for leaks. Then it is tested for evaporation of the barrel as well as detected for paste. A plastic bottle is placed in the insulated cotton and the evaporation bottle is covered with paste with Wan Neng jiao.

3 2. The wire is cut to the required length. It is very easy to put together and the wire is then bent and a protective cover is placed on it. 3. Then the thermostat button is pressed to see whether the button is sensitive enough. The wire for the thermostat is then set into the glass tube. The fan blades are attached to the motor and later locked into place. 4. The return pipe has a size for production that has been previously decided. The sizes for the return pipe, exhaust pipe, condenser, and evaporator are all pre-determined. However there are certain rules which have to be followed, such as the bend should be at a 90 degree angle and the copper tube should be strained instead of being flattened.

4 5. There is the filter, reservoir irrigation, condenser, four-way solenoid valve, and take over welding; there is a monopoly over the tube welding process. The other length of 150MMφ9.52 copper tube has 3 filters in one and the other one is used for interface and welding. The liquid storage for the welding has a capacity of 405MMφ9.52, which takes over the other end. The electronic valve was made into a 4 way valve, with the condenser take over, the return pipe as well as the exhaust pipe and evaporative barrel. All of these were welded, then the tube is heated until it s a golden color ( ). Then solder is added so that all the gaps are filled. 6. The Lando water chiller has a front made from silk and a Lando logo on the bottom, which is four feet away from the end. The compressor itself is attached to the base, and the evaporation barrel itself is on the base. The compressor is then condensed and installed to the base. The two electrical boxes are screwed into the floor and to the nut lock as well. 7. Machine tube welding: first the assembled electromagnetic four way valve is attached to the base of the tube docking. Then the three-way collection tube, as well as the liquid irrigation, is welded and then the condenser takes over the exhaust pipe. The welding for the return pipe is good. The welding for the solder is required to be very smooth. There should be no rough edges.

5 8. Machine inflatable test: the first of the filter tube is connected to the nitrogen gas which is then tested, then soap bubbles are used to test out the entire tube system to see if there are any leaks. An insulation tube is used to check the evaporator in the barrel titanium tube. After this, the tube will be pressed to so the insulation can be tightened even closer to the copper tube. This will then be loaded to the base of the fan, then the fan will be tested to see if the condensation happens. 9. Machine connection: the fan ground, compressor ground, and the power ground all culminate at the same location in the electrical box on the same power line with a blue control panel to denote it. The panel has a black line, the fan has a white line, and the solenoid valve has a blue line. The wiring is assembled into the electrical box cover. 10. Vacuum: the nitrogen is removed from the tube. Then the switch of the vacuum is started. The vacuum time is 40 minutes or more on average. This is to ensure that the vacuum is below 20PA.

6 11. Installing the temperature probe: there is a circle of cotton placed around the temperature sensor probe so that the hot liquid, which is a result of melting, does not hit the titanium tube bottom. Then the middle of the titanium tube is sealed up with a hot glue gun. The nozzle is also fixed with the hot glue gun. 12. Refilling the refrigerant: before the refrigerator is calibrated, the refrigerant is refilled. This is done through the filter process tube quick connector and the refrigerant connector s docking. If it is not 20Pa after the vacuum connection, then it will automatically re-vacuum itself as the refrigerant is refilled. 13. Installing the shell: the first place which has to be shelled is the base, following which, the screw hole is locked. Since it will be dealing with water, the shell on the cover will safeguard it. The thermostat will be installed after this. Once this is done, the panel will be inserted into the house, using the M4 * 6 crosshead screw with the φ4 gasket with the screw-hole to lock the panel of the housing.

7 14. Once the production process is finished, the finished product is checked for quality assurance. Its appearance is tested first, after which, it is connected to an outlet and tested for operation. It is seen whether the temperature displayed on the screen is 2 degrees different from the current temperature. After three minutes of being turned on, it should be stable and heat or cool as required. There should be no noise coming from the compression, the copper tube, the shell, fan collision, or any other part. The machine running light sound however is to be expected and is normal. The water machine s thermostat shows that it is adjusted to about 25 degrees, and when the parameters are specified, the chiller, however, should not affect the plastic handles on both of its sides as well as the connector and nut fittings. Once all of this is ensured, put the chiller in a white plastic bag which is then placed in a box which can be shipped to anywhere in the world.

8 Shenzhen Lando Technology Industrial Co.,ltd Address : Longgang Shenzhen, Guangdong, China. Mobile: (WhatsApp available ) sales@cnlando.com

Troubleshooting(TC32G)

Troubleshooting(TC32G) Troubleshooting(TC32G) tools: Tool description (Note: Most of the repairing is same as VT60 s, so we use VT60 s picture) (1) the wine cellar does not get cold at all. 1 Check to ensure the power plug is

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

OIL COOLER INSTRUCTION HANDBOOK

OIL COOLER INSTRUCTION HANDBOOK OIL COOLER INSTRUCTION HANDBOOK INDEX 1. GENERALITY 2 1.1 OPERATING RANGE 1.2 IMPORTANT 2. INSTALLATION 3 2.1 TRANSPORTATION 2.2 INSTALLATION LOCATION 2.3 PIPING 2.4 WIRING (see the electrical diagram

More information

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600

More information

REFRIGERANT PIPING

REFRIGERANT PIPING SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

Ratio Architects, Inc. Section Refrigerant Piping

Ratio Architects, Inc. Section Refrigerant Piping SECTION 232300 - REFRIGERANT PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant pipes and fittings. 2. Refrigerant piping valves and specialties. 3. Refrigerants. 1.2 ACTION SUBMITTALS

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

HeatPro HEAT PUMP REPLACEMENT PARTS

HeatPro HEAT PUMP REPLACEMENT PARTS Parts Diagram: HP20654T, HP20654BT, HP20854BT, HP20854T, HP21104T, HP21104TC Parts Listing: HP20654T, HP20654BT, HP20854T, HP20854BT, HP21104T, HP21104TC Ref. No. Part No. Description 1 HPX01023502 Fan

More information

Chilller Arctic Instruction Manual

Chilller Arctic Instruction Manual Chilller Arctic 1200 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that

More information

Service Manual. Air Conditional

Service Manual. Air Conditional Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30CM -3 - CONTENTS SPECIFICATION...

More information

PROJ. NO SECTION REFRIGERANT PIPING

PROJ. NO SECTION REFRIGERANT PIPING SECTION 23 23 00 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160. No.: HMRSM03-011 Service Manual Solar Direct Drive Vaccine refrigerator Model:HTC-60H & HTCD-160 Pictures: HTC-60H HTCD-160 Haier Medical and Laboratory Products Co,.Ltd Contents 1. Model definition...

More information

Spare Parts Catalogue MV1006

Spare Parts Catalogue MV1006 Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates

More information

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

Marine Heat Exchangers SALES SERVICE REPAIR

Marine Heat Exchangers SALES SERVICE REPAIR Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL

More information

Heat Transfer Equipment

Heat Transfer Equipment Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet

More information

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model

More information

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL Ideal for ponic System Reservoirs 1/2 HP 53-317 GALLONS (200 TO 1200L) AACH50 INSTRUCTION MANUAL Before operating this appliance, please read the instruction manual thoroughly and keep on file for future

More information

INSTALLATION & MAINTENANCE MANUAL

INSTALLATION & MAINTENANCE MANUAL MICOCHANNEL HEAT EXCHANGE INSTALLATION & MAINTENANCE MANUAL Version1.1 三花丹佛斯 ( 杭州 ) 微通道换热器有限公司 DANFOSS SANHUA (HANGZHOU) MICO CHANNEL HEAT EXCHANGE CO., LTD. MAKING LIVES MOE COMFOTABLE THU INNOVATION

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)

More information

SERVICE MANUAL FOR MODEL RM-10

SERVICE MANUAL FOR MODEL RM-10 SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER

More information

REFRIGERATION PRODUCTS

REFRIGERATION PRODUCTS REFRIGERATION PRODUCTS Product Catalog REFRIGERATION PRODUCTS PAUL MUELLER COMPANY Table of Contents 3 x 5 Falling Film Chiller.................................... 1 4 x 8 Falling Film Chiller...................................

More information

Service Manual. Air Conditional

Service Manual. Air Conditional Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30HM -3 - CONTENTS SPECIFICATION...

More information

Parts introduction FRONT BACK

Parts introduction FRONT BACK Lando Industrial Water Chillers installation instructions Thank you for using the machine from Shenzhen Lando Technology Industrial Co.,Ltd.. Please read the installation instructions carefully before

More information

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER BIGGER-H SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional R&D

More information

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP. DISTRIBUTED BY

INSTRUCTIONS WATER CHILLERS. Active Aqua Chiller, 1/10 HP. Active Aqua Chiller, 1/4 HP.  DISTRIBUTED BY WATER CHILLERS Active Aqua Chiller, 1/10 HP Active Aqua Chiller, 1/4 HP DISTRIBUTED BY CHILLER 1/10 HP (13-50 GALLON) Control box Circuit board Back cover of circuit board Top cover Water inlet & outlet

More information

SERVICE MANUAL FOR MODEL RM-49

SERVICE MANUAL FOR MODEL RM-49 SERVICE MANUAL FOR MODEL RM-49 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED

More information

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT Central Chiller Plant (with Cooling Tower and Chilled Water distribution) The other AC configuration is called a Chilled Water or Larger Cooler system. It

More information

Public Services Building 155 N First Avenue Hillsboro, OR March 2012

Public Services Building 155 N First Avenue Hillsboro, OR March 2012 Public Services Building 155 N First Avenue Hillsboro, OR 97124 March 2012 Tests and report done by: Joel Klobas Emerging Energy Solutions Technical Director joelk@eeswest.com Contents Introduction...

More information

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains

More information

Refrigeration Technology in Building Services Engineering

Refrigeration Technology in Building Services Engineering Unit 70: Unit code: T/600/0459 QCF Level: 3 Credit value: 10 Guided learning hours: 60 Unit aim Refrigeration Technology in Building Services Engineering This unit develops an understanding of the principles,

More information

SB Series Brazed Plate Heat Exchanger Installation Manual

SB Series Brazed Plate Heat Exchanger Installation Manual SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual

More information

TROUBLESHOOTING VANGUARD

TROUBLESHOOTING VANGUARD TROUBLESHOOTING VANGUARD IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring. WARNING: Disconnect electrical power to the Unit to prevent personal injury

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. SECTION 23 23 00 (15530) - REFRIGERANT PIPING 3. Joining Materials. 4. Specialties. B. Related Sections: 1.02 REFERENCES 1. Section

More information

Air Cross 21 Installation and User Manual

Air Cross 21 Installation and User Manual Air Cross 21 Installation and User Manual 1 Introduction AirCross BPHE is a stainless steel cross flow plate heat exchange which is vacuume brazed with pure copper or nickel based material as the brazing

More information

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting

More information

DESIGN STANDARDS SECTION 15600

DESIGN STANDARDS SECTION 15600 PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating

More information

an ISO 9001:2015 Registered Company

an ISO 9001:2015 Registered Company an ISO 9001:2015 Registered Company Mark IV (672001-VHY) 18865 Goll St. San Antonio, TX 78266 Phone: 800-862-6658 Sales: sales@vintageair.com Tech Support: tech@vintageair.com www.vintageair.com 902001-VHY

More information

Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283

Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283 Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283 2 / 18 This is a service guideline for possible failure and repair. Warning: before attempting any cleaning or maintenance

More information

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current Fengwangdong Zhang On behalf of CMS Pixel Collaboration The 9th International Workshop on Semiconductor

More information

Beverage Air IMPORTANT

Beverage Air IMPORTANT Beverage Air IMPORTANT INFORMATION FOR CT96 MODEL This cooler has passed the QUALITY CONTROL INSPECTION And meets the high standards for Beverage-Air Refrigeration products IMPORTANT PLEASE RETAIN FOR

More information

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL an ISO 9001:2008 Registered Company 18865 GOLL ST. - SAN ANTONIO, TX. - 78266 - ph.210-654-7171 - fax 210-654-3113 MINI SPACE SAVER HEAT /COOL 01000-QUX-A 01000-VUX-A 900101-VUX-A REV C 3/5/14, MINI SPACE

More information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table

More information

Model Illustrated DZ400A

Model Illustrated DZ400A User Manual SINGLE CHAMBER VACUUM PACKING MACHINE DZ300A and DZ400A Model Illustrated DZ400A INDEX 1. SUMMARY. 2. USAGE. 3. FEATURES. 4. TECHNICAL SPECIFICATIONS. 5. STRUCTURE AND PRINCIPLE. 6. PANEL OPERATATION

More information

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5 GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5 CONTENTS Key features...p.1 Product contents...p.1 Safety information...p.2 Maintenance...p.2 How it works...p.5

More information

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers What Sets Delta T Systems Chillers Apart? Variable Speed Compressor The compressors used

More information

Instruction Sheet

Instruction Sheet Instruction 16027095 Sheet Description: Side-by-Side Frost Kit Repair Part Number: 12002756, 12002692 Kit includes: 67005901 High Pitched Blade 67006135 Heat Shrink 61001586 Fan (2) Permagum (Butyl) 61003828

More information

MINI SLIMLINE COOL VUY-A VUY-A

MINI SLIMLINE COOL VUY-A VUY-A an ISO 900:2008 Registered Company MINI SLIMLINE COOL 030-VUY-A 040-VUY-A 8865 GOLL ST. - SAN ANTONIO, TX. - 78266 ph.20-654-77 - fax 20-654-33 900302 REV D 0/28/4, MINI SLIMLINE COOL PG OF Table of Contents

More information

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................

More information

Heat exchanger plates

Heat exchanger plates The heat exchanger plate has the function to enable the transfer of heat between two fluids with different chemical-physical features, with no mixing between them. These, are preferred compared to shell

More information

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water. Temperature Control Units Water & Oil 0-00 F Portable Chillers ir & Water-Cooled 0-70 F Central Chillers ir & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-0 gallons

More information

HEATING AND VENTILATION

HEATING AND VENTILATION SECTION 14-102.04 14-102.04/ 1 2007OC19 DESCRIPTION The heating, ventilation and air conditioning (HVAC) system is designed to optimize passenger comfort. The system regulates interior vehicle atmosphere,

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING

More information

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE SAWAFUJI ELECTRIC CO., LTD. GENERAL: This appliance is designed to convert

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions.   Up to Foodservice Solutions Refrigeration solutions to lower energy costs and reduce environmental impact Up to 50% energy savings; direct benefit to the bottom line www.danfoss.com Elevating Your Offering Energy

More information

FALLING FILM CHILLERS

FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Paul Mueller Company s Other applications include

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

DCE33 SERVICE PARTS TABLE OF CONTENTS CABINET...PAGE 2 MAJOR ASSEMBLIES...PAGE 3 DRAIN PUMP PARTS...PAGE 4 CONDENSING UNIT...

DCE33 SERVICE PARTS TABLE OF CONTENTS CABINET...PAGE 2 MAJOR ASSEMBLIES...PAGE 3 DRAIN PUMP PARTS...PAGE 4 CONDENSING UNIT... The section contains the parts list for the DCE33. The DCE33 has been manufactured in either a White or a Black finish. Please check the part description before ordering any part. TABLE OF CONTENTS CABINET...PAGE

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

A. Set-Up with gravel

A. Set-Up with gravel A. Set-Up with gravel Set-up tank 10 days before eggs arrive to condition the water and ensure all equipment is working. 1 Gravel Dust-free epoxy-coated gravel is recommended. For 20 gallon tanks use 5kg

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

CABINET PARTS For Models: KSBP25FKSS01 (Stainless Steel)

CABINET PARTS For Models: KSBP25FKSS01 (Stainless Steel) CABINET PARTS REFRIGERATOR 8 03 Litho In U.S.A. (kdj) 1 Part No. Rev. B LITERATURE PARTS 1 LIT2221516 Use & Care Guide LIT2214447 Service & Wiring Sheet LIT2220332 Energy Label LIT628370 Modular Icemaker

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

AIR-COOLED SCREW CHILLER

AIR-COOLED SCREW CHILLER IR-COOLED SCREW CHILLER TRUST IR CONDITIONING EQUIPMENT CO. Prepared y: Engineering & R & D Department. Shiraz- UG 015 Maintenance and Commissioning 1. Commissioning 1.1 Electrical System Connection Inspection

More information

Refrigeration System with a Capillary Tube and a Thermostat

Refrigeration System with a Capillary Tube and a Thermostat Exercise 2-1 Refrigeration System with a Capillary Tube Part A: REFRIGERATION CIRCUIT OBJECTIVE When you have completed this part, a refrigeration circuit using a capillary tube as a metering device will

More information

Air Conditioning Components

Air Conditioning Components Air Conditioning Components Agenda AC Components Compressor & Clutch Condenser Receiver-drier or Accumulator Expansion Valve or Orifice Tube Evaporator Compressor 2 primary purposes Increase pressure &

More information

CABINET PARTS For Models: KSCS25FKSS00 (Stainless Steel)

CABINET PARTS For Models: KSCS25FKSS00 (Stainless Steel) CABINET PARTS REFRIGERATOR 8 03 Litho In U.S.A. (kdj) 1 Part No. Rev. C CABINET PARTS LITERATURE PARTS 1 LIT2254909 Use & Care Guide LIT2214447 Service & Wiring Sheet LIT2220332 Energy Label LIT628370

More information

Upright Chiller & Freezer Service, Installation and Care Manual

Upright Chiller & Freezer Service, Installation and Care Manual Upright Chiller & Freezer Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim 2 2174748 Front Roller (2) 3 489456 Screw 4 981122 Roller (Rear) (2) 5 489427 Screw 6 2155013 Clip, Grille 7 489478 Screw 9 2156056 Shim 12 2196046 Hinge Top (2) 13 2196048 Shim, Hinge Top 14 489284 Screw

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel)

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel) CABINET PARTS 42" BUILT IN REFRIGERATOR 10 11 Litho In U.S.A. (jdc)(psw) 1 Part No. Rev. A 1 Literature Parts W10161714 Use & Care Guide W10164072 Energy Guide W10159832 Service & Wiring Sheet 2306424

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel)

SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel) SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel) 03/21/2018 2018 Whirlpool Corporation Part No. W11157383 Rev. B

More information

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units) Distributed By: Commercial Refrigeration Service, Inc. WWW.866IceMakers.COM 866-IceMakers 623-869-8881

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

CABINET PARTS For Model: KSSC48QVS02 (Stainless Steel)

CABINET PARTS For Model: KSSC48QVS02 (Stainless Steel) CABINET PARTS 48" BUILT IN REFRIGERATOR 2 10 Litho In U.S.A. (mjb) (psw) 1 Part No. Rev. A CABINET PARTS 1 Literature Parts W10161714 Use & Care Guide W10205644 Energy Guide W10159832 Service & Wiring

More information

Elevating Your Offering

Elevating Your Offering Elevating Your Offering Energy Efficiency Electronic or mechanical expansion valves regulate with greater speed and precision than capillary tubes, ensuring your system always runs at peak performance

More information

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR REPAIR PARTS LIST Model Nos. 106.50202993 (White On White) 106.50204993 (Bisque) 106.50209993 (Black) 106.50203993 (Graphite) REFRIGERATOR The model number of your refrigerator is found on the serial plate

More information

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION INSTRUCTION MANUAL FOR Freeze Dry Systems FDL-10N-50 series PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-04.10

More information

VANGUARD 245 POST-MIX DISPENSER

VANGUARD 245 POST-MIX DISPENSER Anoka, MN. 0-. VANGUARD POST-MIX DISPENSER PART NO. 170xxxxx 1708xxxxx 7708xxxxx 771xxxxx 7718xxxxx 970xxxxx 9708xxxxx 971xxxxx 9718xxxxx VANGUARD (POST-MIX) 1 of 1 Anoka, MN. 0- VANGUARD POST-MIX DISPENSER

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are: Technical Review of a Remote Condenser Cuber with Enhanced Refrigeration and Water Systems using CM 3 Technology models included are: CME1356 shown on BH900 CME456, CME1056, CME1356, CME1656 and CME2006

More information

Installation Manual BCS2000/3000

Installation Manual BCS2000/3000 Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for

More information

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

Refrigerated Compressed Air Dryer

Refrigerated Compressed Air Dryer Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED

More information