EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

Size: px
Start display at page:

Download "EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada."

Transcription

1 EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

2 The First Fan The first chimney fan - a first worldwide and the foundation of EXHAUSTO s existence

3 A 50-year Old Company Founded in ,000+ sq.ft. of manufacturing and administration High-tech ISO 9001 certified manufacturing facilities

4 Certifications

5 Mechanical Draft Systems

6 Products RSV Fan Capacity: 6,000 MBH on CAT I Appliances 10,000 MBH on CAT IV Appliances 3/16 Cast aluminum housing Hinged for easy service and cleaning Direct drive Class H insulated motor Maintenance free 482 ºF Continuous Duty 575 ºF Intermittent Duty UL 378 Draft Equipment

7 Products RSV Fan The RSV fan can vent all appliance categories with or without barometric dampers Up to 6,000-10,000 MBH High temperature motor eliminates the need for secondary fan cooling Simple design with few components reduces the risk of failure and simplifies service

8 CASI Chimney Automation System

9 RSIB Power Venter Capacity: 8,000 MBH on CAT I Appliances 15,000 MBH on CAT IV Appliances SS316 construction Removable access door Direct drive Class A insulated motor - eliminates the need for secondary fan cooling Maintenance free Up to 575 ºF Duty The RSIB fan can vent category I, II, III & IV appliances Simple design with few components reduces the risk of failure and simplifies service RSIB is of Type B, Spark Resistant Construction UL 378 Draft Equipment

10 RSIF Power Venter Capacity: 1,800 MBH on CAT I Appliances Rated to 400 F non-condensing applications Forward inclined impeller. Statically and dynamically balanced. Insulated housing in galvanized steel Hinged fan housing easily opens to provide easy access to duct and impeller Direct drive, variable speed, TEFC motor located outside housing for easy access.

11 Modulating Overdraft Damper System

12 Controls EBC30 Modulating Pressure Control

13 Controls EBC30 Features 100% microprocessor based control Plug-and-Play initialization process Integrated PDS function with adjustable time delay Intermittent or continuous operation for all fans Field-adjustable PID loop Priority Operation function Bearing Cycle function Rotation Check for three-phase fans

14 Controls PDS Proven Draft Switch Differential pressure transducer Ensures proper draft before and during appliance operation Probe included Range: 0.04 to 0.60 W.C.

15 Controls VFD Variable Frequency Drive Pre-programmed from the factory 1 5 HP in 200 Volt Class input 1 7. All wiring is done externally conduits and wires are pre-installed Quick-menu for field adjustable Parameters NEMA 1 rating

16 Products Accessories SCA Steel Chimney Adapter Steel chimney adapter Used as transition between a round stack and the fan Made of 304 stainless steel

17 Products Accessories BBF Balancing Baffle Balancing baffle with flange connections For positive pressure stacks For balancing pressure drops on systems with multiple appliances

18 CASV Applications Stack Downsizing Hazen High School Renton, WA Soldier Field - Chicago, IL

19 CASV Applications - Aesthetics Getty Center Los Angeles Rigel San Francisco

20 MCAS Mechanical Combustion Air Supply Systems

21 MCAS Modulating Combustion Air Supply System

22 MCAS Components SFTA Fan Seven Models 1,500 30,000 cfm Fan can be mounted indoors Impeller cast aluminum. Housing in steel Direct drive, variable speed, TEFC motor located outside housing for easy access. Variable Frequency Drive is used on three phase models (VFD should be located inside the building).

23 MCAS Components BESF/BESB Fan Seven Models cfm Fan can be mounted indoors or outdoors. Impeller - statically and dynamically balanced. Insulated housing in galvanized steel Hinged fan housing easily opens to provide easy access to duct and impeller Direct drive, variable speed, TEFC motor located outside housing for easy access. Variable Frequency Drive is used on three phase models In-door or out-door installations (VFD should be located inside the building).

24 EBC30 Modulating Control Modulating Combustion Air Supply System Chimney Automation System

25 SBC Center San Antonio, TX Two 16 inch ducted combustion air inlets Instead of Two 10 foot high by 15 foot long Louvers

26 Lifetime Fitness Savage, MN

27 Marriott Waterfront Annapolis, MD One 24 inch ducted combustion air inlet Instead of One 90 ft.² louver

28 MDVS Mechanical Dryer Venting Systems

29 MDVS Mechanical Dryer Venting System

30 MDVS Components - BESB Fan Four Models cfm ETL Listed to UL705 :"The product (BESB/MDVS) covered by this report is a modulating air exhaust system. The product consists of a box ventilator and a modulating control for permanent installation. Its intended use is exhausting of lint-laden air from single or multiple type I and type II residential and commercial clothes dryers whether electric or gasfired, exhausting commercial hoods, or for providing make-up air for laundries or mechanical rooms. The box ventilator can be installed indoors or outdoors."

31 MEC 18 Control Monitor draft in multi-story building exhaust applications Controls RSV, EFH, BESF and BESB EBC12 functions UL 508 and CSA C22.2 Standard for Industrial Control Equipment

32 Kitchen and Dryer Exhaust Madigral Lofts, MD

33 Applications Sports Arenas Hotels Hospitals Schools Fitness Facilities Apartments / Condominiums

34 Appliance Categorization Atmospheric Fan Assisted Forced Draft Scotch Marine Draft Hood Draft Diverter I III Negative Fan Assisted (high efficiency) II IV Condensing Positive

35 Z (Venting of equipment) 12.1 Minimum Safe Performance A venting system shall be designed and constructed so as to develop a positive flow adequate to remove flue or vent gases to the outside atmosphere Equipment Draft Requirement A venting system shall satisfy the draft requirement of the equipment in accordance with the manufacturer s instructions.

36 Common Code Violations (NFPA 54) Z (Venting of Equipment) (NFPA 54) Z (Sizing of Venting Systems)

37 Common Code Violations 3" 4" 5" 6" 7" 8" 9" 10" 12" 14" 16" 7" 10" 12" 14" 18" 22" 22" 26" 30" 36" 42" (NFPA 54) Z223 Sizing Tables (NFPA 54) Z (Sizing of Venting Systems)

38 Mechanical Draft Systems Defined Z Standard for Venting of Equipment Mechanical draft systems shall be listed and shall be installed in accordance with the terms of their listing and both the appliance and the mechanical draft system manufacturer s instructions Appliances requiring venting shall be permitted to be vented by means of mechanical draft systems of either forced or induced draft design. Exception: Incinerators Where a mechanical draft system is employed, provision shall be made to prevent flow of gas to the main burners when the draft system is not performing so as to satisfy the operating requirements of the equipment for safe performance

39 Commercial Laundry Radisson, Orlando, FL

40 Responsibility Reduce Emissions Environmentally friendly Low Energy Recyclable Materials Demand-Controlled

41 And Still Going Strong... Reliable Disney Allstar Resorts Orlando, Florida 60 RSV installed 2 RSV replaced The White House Washington D.C 12 RSV installed Sample 3 xx RSV installed

42 Eliminates Potential Risks Seismological Safe

43 Eliminates Potential Risks Seismological Safe

44 Case: CBS Studio, Hollywood, CA Boiler replacement. Must meet air quality requirements and eliminate need for substantial stack work. Solution: Four condensing boilers installed in a modular system using a single common stack and a CASV system for venting. Benefits: Simple and Aesthetically pleasing Limited stack work using existing chase

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards Venting- on-demand Minimizing Energy Loss through the Exhaust Ventilation Systems in order to meet Sustainable Design Standards Approach Controlled Venting Versus Natural Venting Controlled Air Supply

More information

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications. 3913017 03.15 Submittal Data MDVS 250-500 Tag: DF-1, DF-2 Job Name: Parkside Memory Cottage ALF Representative: Tom Barrow Company Job Location: Port Charlotte, FL Job #: 80036 Architect/Engineer: Contractor:

More information

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems 23 51 13/EXH BuyLine 8599 Chimney Automation Systems Multistory Fireplace Exhaust Systems Mechanical Dryer Venting Systems

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications

Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications ASHRAE Qatar Oryx Chapter 10 th November 2012 Presenter: Steen Hagensen Make the unimaginable

More information

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer: Installation & Operating Manual RSV Chimney Fan USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

RSIB Power Venter

RSIB Power Venter Installation & Operating Manual RSIB 300-500 Power Venter USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

ENERVEX RSV CHIMNEY FAN

ENERVEX RSV CHIMNEY FAN ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual RSIF Power Venter USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3002239 09.03 USA CAN RSIF Power Venter READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries TRUE GREEN SOLUTIONS NEW For Commercial and industrial Baking Oven Systems Variable Speed and Direct Drive Natural Gas, LP Gas and

More information

EBC 12 Modulating Fan Control

EBC 12 Modulating Fan Control Installation & Operating Manual EBC 12 Modulating Fan Control USA CAN Product Information... Chapters 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual EBC 10 Fan Control USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

ENERVEX IPVB INLINE POWER VENTER

ENERVEX IPVB INLINE POWER VENTER ENERVEX IPVB 300-500 INLINE POWER VENTER 3002600 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ETL514733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P:

More information

IPVB EC inline power venter

IPVB EC inline power venter Installation and operation manual IPVB 300-500 EC inline power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation Chapter

More information

MEC 18 Mechanical Exhaust Control

MEC 18 Mechanical Exhaust Control Installation & Operating Manual MEC 18 Mechanical Exhaust Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX Boiler Venting Definitions, Theory and Applications Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX Gas Appliance Listings ANSI Z21 - Categorized Appliances Gas fired low

More information

Venting Modern Heating Appliances

Venting Modern Heating Appliances Venting Modern Heating Appliances by Michael Beisheim VentBOM Visual Vent Michael has more than 25 years of experience with Venting. This includes development of patented Draft Controls. His Design Software

More information

CONDENSING HIGH EFFICIENCY BOILERS

CONDENSING HIGH EFFICIENCY BOILERS Built by 3I Innovative Industrial Inc. ABS Series CONDENSING HIGH EFFICIENCY BOILERS ABS 1500-2000-2500-3000-4000MBH Cast aluminum heat exchanger 10 to 1 turndown ratio Honeywell Sola boiler control system

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS AHRI Certified up to 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS Harsco Industrial Patterson-Kelley delivers premium quality boilers that consistently produce the ROI customers demand.

More information

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3001806 03.02 USA CAN BESF Box Ventilator READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016 Forced Draft Boiler Flue Gas Venting: Problems & Solutions Presented by Steve Connor and Patrice Gouin January 27, 2016 What Will We Be Covering Today? Pressurized Non-condensing Vent Systems Venting s

More information

Multistory Fireplace & Exhaust System

Multistory Fireplace & Exhaust System Optimize Your Venting Designs Multistory Fireplace & Exhaust System From the leaders in venting and fireplace systems EXHAUSTO and Isokern Fireplaces & Chimney Systems Build the perfect fire with the perfect

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007 Draft D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007 Draft For proper operation and efficient fuel consumption in oil, gas, and/or coal-fired heating appliances,

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

Tjernlund Side Wall Venting Products

Tjernlund Side Wall Venting Products Tjernlund Side Wall Venting Products Any non-condensing gas or oil fired heater that can be vented by natural draft can be Side Wall Vented with a Tjernlund Power Venter. Power Venters are available in

More information

THE ULTIMATE VENTING SYSTEM

THE ULTIMATE VENTING SYSTEM THE ULTIMATE VENTING SYSTEM INTEGRATED CHIMNEY VENTING SOLUTION FOR BOILERS & WATER HEATERS NEW CHIMNEY SYSTEM Photo COMBUSTION AIR SUPPLY SYSTEM MECHANICAL DRAFT SYSTEM WASTE HEAT RECOVERY SYSTEM T: +1

More information

Draft Controls. When to use a Draft Control

Draft Controls. When to use a Draft Control Draft s For proper operation and efficient fuel consumption in oil, gas and/or coal-fired heating appliances, draft must remain constant. When it is, combustion is more complete, fuels are utilized efficiently,

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL TRIIUMPH SERIIES AIIR SUPPLY AND VENTIING GUIIDE C.S.A Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam & Hot Water Boilers ASME Code Section IV C.S.A Design-Certified Complies

More information

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer without Boiler Replacement TRUE GREEN SOLUTIONS NEW Patent Pending EcoFlex + System Modulating Fan-Powered Economizer EcoFlex + System Because They Are Your Btus EcoFlex + System - a packaged modulating

More information

Multistory Fireplace & Exhaust System

Multistory Fireplace & Exhaust System Optimize Your Venting Designs Multistory Fireplace & Exhaust System From the leaders in venting and fireplace systems ENERVEX and Isokern Fireplaces & Chimney Systems Build the perfect fire with the perfect

More information

FIELD DRAFT CONTROLS

FIELD DRAFT CONTROLS INDEX TYPE M... 7-7 TYPE MG-1... 7-8 TYPE M+MG2... 7-9 TYPE RC... 7-6 INTRODUCTION... 7-2 7-5 Expert Service. Quality Products. Since 1960. www.eccosupply.ca 7-1 For proper operation and efficient fuel

More information

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS Tradition, Knowledge and Innovation are the three pillars that support all we do at Harsco Industrial Patterson-Kelley. Tradition Building on more than 10 years

More information

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

ENERVEX VHX VORTEX HEAT RECOVERY CENTER ENERVEX VORTEX HEAT RECOVERY CENTER 3002603 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F:

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS WHITEPAPER Decades of evolving codes have led to much confusion over how dampers can and cannot be used. Contrary to popular belief, manual

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

fans & heaters SIMPLE, ROBUST AND RELIABLE

fans & heaters SIMPLE, ROBUST AND RELIABLE FANS & HEATERS fans & heaters SIMPLE, ROBUST AND RELIABLE For over 50 years, NECO has specialized in agricultural equipment engineering and manufacturing. NECO produces market leading grain dryers and

More information

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* *Vented appliances refer to natural draft appliances equipped with a barometric draft regulator or Category I appliances equipped with a draft

More information

ENERVEX GSV GREASE FAN

ENERVEX GSV GREASE FAN ENERVEX GSV 200-450 GREASE FAN 3001391 12.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

ADC150 Automatic Draft Control

ADC150 Automatic Draft Control Installation & Operating Manual ADC150 Automatic Draft Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Boiler Technical Specifications (2013)

Boiler Technical Specifications (2013) ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)

More information

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions R-Series Oil Burners Maximum Performance. Minimum Maintenance. Oil Riello Burners a world of experience in every burner we sell Across North America and the world over, Riello sets the standard in reliable,

More information

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances Boiler: Project and Design Support exodraft solutions are so much more than just products and systems.

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

LARGE CAPACITY HEATERS

LARGE CAPACITY HEATERS 250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS

More information

ENERVEX ADC100 DRAFT CONTROL

ENERVEX ADC100 DRAFT CONTROL ENERVEX ADC100 DRAFT CONTROL 3916067 04.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. GQVC-12 HVAC EQUIPMENT GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. 80% thermal efficiency. Heat Exchangers have a tough job to do. It's no

More information

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 20-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS s superior ability to absorb and transfer heat makes it the ideal choice for comfortable and efficient heating systems. Since 11 Bradford White Corporation has been dedicated to building the highest quality,

More information

DOM-5. Domestic Hot Water Heaters & Boilers

DOM-5. Domestic Hot Water Heaters & Boilers DOM-5 Domestic Hot Water Heaters & Boilers Unlike other manufacturers, which rely solely on achieving high operating efficiency, the Dominator Series is designed for total efficiency based on operating

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN Installation & Operating Manual 3000270 10.01 USA CAN RS Chimney Fan For Gas & Oil Applications 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731 info@exhausto.com

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

GB Condensing Gas Boiler

GB Condensing Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB162/100 wall-hung condensing hot water boiler(s), suitable for

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage R ISO 9001 COMMERCIAL DOMESTIC HOT WATER GENERATOR Gas, Oil or Combination Gas/Oil 199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage NOW AVAILABLE WITH... NO TANK LINING REQUIRED NO ANODES REQUIRED

More information

Air and technology System solutions with a perspective... System solu

Air and technology System solutions with a perspective... System solu Air and technology System solu solutions with a perspective... Two business sectors beneficial to the indoor climate The key goal for EXHAUSTO is to create a healthy, well-functioning indoor climate. It

More information

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS XVERS TYPE H - MODELS 0856-3006 SUGGESTED SPECIFICATIONS Catalog No.: 2000.84A Effective: 06/22/18 Replaces: 3/15/18 DIVISION 23 52 33.13 FIRE-TUBE STAINLESS STEEL HEATING BOILERS - GENERAL 1.1 SUMMARY

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating cod. Doc-0079191 rev. 3 12/2017 High efficiency commercial heating RTC Stainless Steel Condensing Floor Standing Boilers Technical data sheet High water content 3-pass stainless steel (316Ti) condensing

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications Installation & Operating Manual RS Chimney Fan for Solid Fuel Applications USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com HybridSeries WOOD & Combination FUEL Furnaces Continental s Hybrid Multi Fuel Combination Furnaces are extremely clean burning

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

DACC Health Sciences Building Air Handler Assessment/Study

DACC Health Sciences Building Air Handler Assessment/Study DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information

Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)

Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below) CALIFORNIA MECANICAL CODE MATRIX ADOPTION TABLE CAPTER CIMNEY AND VENTS Adopting Agency BSC SFM CD DSA OSPD 1 1/AC AC SS SS/CC 1 4 Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended

More information

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty. R C ONQUEST TM Condensing Water Heater UP TO 97% THERMAL EFFICIENCY AT FULL RATE FROM 40 F TO 140 F TANK AND HEAT EXCHANGER MADE FROM AquaPLEX ENGINEERED DUPLEX STAINLESS STEEL ALLOY Featuring... SEAMLESS

More information

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: Date: A. Supply and install modulating and condensing boiler(s)/water heater(s)

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com Hybrid 100 For heating requirements up to 1400 sq. ft. the Hybrid100 is up to the task. It can be connected to a new or existing

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g

More information

DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired

DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired INDUSTRIAL DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired 201 Hot Water Boilers THE PARKER DESIGN A time proven product backed by one of the largest and

More information

Concrete Applications

Concrete Applications Concrete Applications Sioux Industrial Water Heaters Sioux has been a leading supplier of water heaters to the concrete industry since the 1960s. Sioux offers standard units for any size operation, ranging

More information