DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

Size: px
Start display at page:

Download "DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629."

Transcription

1 DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629.

2 Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces; and appliances using wood, oil, gas, or coal. Materials and Construction Thermal Tech II insulation encased between inner and outer walls of stainless steel. Clearances 2 clearance to combustibles. Diameters 6-8 Listings Listed to UL 103HT and ULC S629 (143-P-03-2). UL 103 HT and ULC S629 System DuraPlus HTC DuraVent's Thermal Tech II lanket insulation in DuraPlus HTC is made of light-weight ceramic refractory material. This insulation will not shrink or cause gaps like competitors products made of mineral wool and other loose-fill insulations. No gaps mean no hot spots to trigger fires to exterior combustibles. Encased between two stainless steel walls, the insulation maintains a barrier that will not shift or settle. The 2 wall keeps the exterior cool, while ensuring high temperatures for optimum draft performance on the inside. Twist-lock feature allows you to assemble DuraPlus HTC quickly and precisely. No screws or rivets required and no locking bands needed either. The djustable Tee Support racket is reversible for installation above or below the tee, while ensuring a 2 clearance to combustibles (adjusts from 2 to 6 ). DuraPlus HTC offers 15, 30, and 45 degree elbows and allows double offsets. Chimney pipe comes in lengths from 6 inches up to 4 feet. Designed for normal, continuous operation at 1200 F (650 C) flue gas temperatures. DuraPlus HTC is subjected to rigorous and stringent requirements of the ULC S629 standard, including one hour at 1700 F (925 C), plus three thirty minute chimney fire tests at 2100 F (1150 C). 61 DuraVent

3 ll-fuel Chimney DuraPlus HTC Typical Installations Multi-Story Oil Furnace Cathedral Ceiling Roof Support ttic Offset Installation Key 1 DuraPlus HTC Chimney Pipe 12 Square Ceiling Support ox 2 Elbow 13 Roof Support 3 Elbow Strap 14 Roof Support Trim Collar (not shown) 4 Tee 15 Roof Flashing 5 Wall Thimble 16 Firestop Radiation Shield (not shown) 6 Tee Support racket 17 Roof Radiation Shield 7 DVL/Duralack Chimney dapter 18 ttic Insulation Shield 8 Chimney Cap 19 DVL or Duralack Stovepipe 9 Storm Collar 20 Stovetop dapter 10 Finishing Collar 21 DVL or Duralack Tee 11 Round Ceiling Support 22 DVL or Duralack Elbow Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. DVL/Duralack Chimney dapter must be used when connecting DVL or Duralack stovepipe to a Ceiling Support, Wall Thimble or Finishing Collar. Wall Thimble must be installed with an appropriate section of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls use a Wall Thimble Extension. n ttic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. If chimney is enclosed in a chase in the attic space, an attic insulation shield is not required. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a ceiling support. Roof Radiation Shield is required at the roof deck penetration. Chimney Cap Extended Roof racket Storm Collar Flashing Roof Radiation Shield Elbow Strap Elbow ttic Insulation Shield Firestop Radiation Shield djustable Wall Strap Second Floor Chase Ceiling Support DVL/Duralack Chimney dapter Duralack Stovepipe or DVL Close Clearance Connector Stovepipe Stove dapter Through-The-Wall Cathedral Ceiling w/support ox DuraVent 62

4 DuraPlus HTC ll-fuel Chimney Planning Your Installation 3 FT. MINIMUM HEIGHT FROM ROOF PENETRTION Figure 1 2 FT. MINIMUM OVE NY PORTION OF UILDING WITHIN 10 FT. 10' MINIMUM CHIMNEY HEIGHT REQUIREMENT The following recommendations are a general guideline to assist in the layout and selection of the chimney components needed for your installation. lways follow DuraVent Installation instructions before installing your chimney system (enclosed with the cap or support box). Installation instructions can be viewed online at under catalogs and instructions. The diameter of the chimney should match the outlet size of the appliance. n improperly sized chimney results in poor draft and excessive creosote formation. Measure the diameter of the appliance flue outlet. Select the chimney and either DVL or Duralack connector stovepipe with the same size diameter as the appliance flue outlet. For fireplace installations, refer to the sizing chart in the back of this catalog. Determine if the installation is a through-the-roof installation or a through-the-wall installation. through-the-wall installation will require additional components (Wall Thimble, Tee/Cap, Tee Support, and Wall Straps). Install the chimney in the interior of the structure whenever possible. cold exterior chimney will produce less draft and will generate more creosote. If possible avoid offsets that serve to restrict the natural draft. straight vertical installation is more efficient and less likely to develop creosote. If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. 15, 30 and 45 elbows are available. (Note: 45 elbows are only allowed in Canada. The maximum angle allowed in the U.S. is 30.) maximum of two offsets in a single installation are permitted. Refer to the offset table in the back of the section of this catalog. t least one Elbow Strap is required for each offset. Elbow Straps ensure adequate support. Determine the minimum chimney height above the roof line. uilding codes require a minimum of 3 above the roof penetration and at least 2 higher than any portion of a building within 10. See figure 1. The termination cap is installed above that point. If chimney is more than 4 above the roof penetration an Extended Roof racket is required. Measure the roof pitch. For example, a 6/12 pitch has a vertical rise of 6 over a horizontal distance of 12. Select the appropriate flashing. Determine the total length of chimney and stovepipe required for the installation. To calculate the installed per length of 6-8 DuraPlus HTC chimney pipe, subtract per joint. Subtract 1 ¼ per joint of Duralack stovepipe. Subtract 1 ½ per joint of DVL stovepipe. Minimum chimney height, at sea level of straight vertical chimney, is 10 to 15 above the appliance outlet. Higher elevations, or the use of elbows or a tee, will require approximately 30% to 60% more height to provide for an adequate draft. e fire safe. Maintain at least 2 clearance to combustibles. Follow local building codes and have your chimney inspected by a certified professional. 63 DuraVent

5 ll-fuel Chimney DuraPlus HTC DuraPlus HTC asic Kit Kit includes: DVL Chimney dapter w/trim, Reduced Square Ceiling Support ox w/ Trim, Chimney Cap, and Storm Collar. Pipe not included. Use for typical through-the-roof installations. Size 6 Stock # C9090 DuraPlus HTC Through-The-Wall Kit Kit includes: DVL Chimney dapter w/trim, Wall Thimble, Tee with Cap, (2) djustable Wall Strap, Tee Support racket, and Chimney Cap. Pipe not included. Use for through-the-wall installations. Size 6 Stock # C9088 Pipe Selection Chart Installed Chimney Height Chimney Sections Used Installed Chimney Height Chimney Sections Used 6 12" " ' ' ' ' ' ' ' ' ' ' ' DuraVent 64

6 DuraPlus HTC ll-fuel Chimney Chimney Pipe Ø Designed for appliances tested and listed for use in the U.S. and Canada with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas. To calculate the installed section of DuraPlus HTC chimney pipe, subtract from each section of chimney pipe. DuraPlus HTC pipe lengths are available with additional protective carton foam for shipping. vailable items have stock # s ending with (CF). Length Ø C9006SS C9106SS C9206SS 12 C9014SS C9114SS C9214SS 18 C9012SS C9112SS C9212SS 24 C9021SS C9121SS C9221SS 36 C9017SS C9117SS C9217SS 36 C9017SSCF C9013SS C9113SS C9213SS 48 C9013SSCF - - Elbow Kit Kit includes: Two Elbows and one Elbow Strap. Use for offsets around obstructions such as rafters, ridgepoles, or joists. May have two pairs of elbows, if needed. Elbows swivel 360 at base (angles are not adjustable). pair of elbows is required to return an offset chimney back to vertical. Made of stainless steel. (Note: 45 elbows are only allowed in Canada. The maximum angle allowed in the U.S. is 30.) 15 6 C9064SSKIT C9164SSKIT C9264SSKIT C9066SSKIT C9166SSKIT C9266SSKIT C9065SSKIT C9165SSKIT C9265SSKIT DuraVent

7 ll-fuel Chimney DuraPlus HTC Universal Elbow Strap 25 2 Use to prevent excessive weight on the elbows by supporting the weight of the chimney. Required to be installed between two elbows in offset installations. dapters included for 7 and 8 straps. Multiple elbow straps may be required for offset installations. Refer to installation instructions C9960 Extended Round Ceiling Support 24 Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Supports up to 40 of DuraPlus HTC Chimney. Use adapter to attach DVL to the support box. Painted black. Trim collar and DVL Chimney dapter w/trim included. dapts to DVL only. Ø C9037 C9137 C Square Ceiling Support ox 18¼ 14¼ Use with flat, vaulted, or cathedral ceilings. Square Ceiling Support ox is painted black. Includes square trim, DVL Chimney dapter w/trim and Insulation Collar. Refer to Ceiling Pitch table to determine size of support box needed. Supports up to 40 of DuraPlus HTC Chimney. Starter Section built in. (For adapters see DVL/Duralack section.) 24 &36 24 SUPPORT OX C9048 C9148 C SUPPORT OX C9048D C9148D C9248D CEILING PITCH DURLCK DVL USE 0/12-4/12 0/12-6/12 24 Support box 5/12-9/12 7/12-13/12 24 Support box 10/12-14/12 14/12-20/12 36 Support box DuraVent 66

8 DuraPlus HTC ll-fuel Chimney Reduced Clearance Square Ceiling Support ox C Use with flat, vaulted, or cathedral ceilings. Square Ceiling Support ox is painted black. Includes square trim and DVL Chimney dapter w/trim. Refer to Ceiling Pitch table above to determine size of support box needed. Supports up to 40 of DuraPlus HTC Chimney. Starter Section built in. Reduces the usual 2 clearance (per side) down to a 1 clearance (per side) for the 6 diameter only. Smaller width allows installation in partial or reduced-joist spaces. SIZE C 6 C C9036D Combustion ir Square Ceiling Support ox Use with Combustion ir System components. Delivers outdoor air as combustion air to the appliance. Operates as a direct vent system without requiring a second penetration to the building envelope. lack. Patent-pending. SIZE CS-CS24HTC 6" 36 6CS-CS36HTC CS-CS24HTC CS-CS36HTC Table ø C / / / /16 Universal Support ox Rails ttach to ouside of Square Ceiling Support ox to stabalize and level installation. One size fits 6, 7, 8 DuraPlus HTC support boxes. Simplifies installation SIZE 6-8 C9948S 67 DuraVent

9 ll-fuel Chimney DuraPlus HTC Roof Support Ø Designed to support the DuraPlus HTC Chimney and allows the chimney to pass through the roof and extend down from the ceiling. Ideal for cathedral ceilings and free-standing fireplace installations. Supports up to a maximum total chimney length of 30 (up to 20 of chimney below) Roof Support. djustable to different roof pitches. Use Finishing Collar and adapter to attach DVL or Duralack to the DuraPlus HTC chimney. Trim Collar not included C9073 C9173 C9273 Universal Roof Support Designed to support the DuraPlus HTC Chimney and allows the chimney to pass through the roof and extend down from the ceiling. Ideal for cathedral ceilings and free-standing fireplace installations. Supports up to a maximum total chimney length of 30 (up to 20 of chimney below) Roof Support. djustable to different roof pitches. Use Finishing Collar and adapter to attach DVL or Duralack to the DuraPlus HTC chimney. Trim Collar not included. dapters included for 7 and 8 Roof Support C9973 Trim Collar for Roof Support 20 Conceals gap between chimney pipe and ceiling cut out when used with Roof Support. Galvalume. Painted black. 19 0/12-12/12 PITCH C9042 C9142 C9242 Finishing Collar 4 Fits into the female end of the chimney pipe to provide a decorative finish. Use on chimney pipe that is suspended with the roof support system. Provides connection to black DVL or Duralack when used with an adapter. (For adapters see DVL/ Duralack section) C9055 C9155 C DuraVent 68

10 DuraPlus HTC ll-fuel Chimney Wall Thimble Ø14 djusts from a minimum of to a maximum of wall thickness, and fits between standard wall studs. If wall is over 11 thick, an Extension Shield must be used, adding up to an extra 16. Interior trim ring painted black. Must be installed with DuraPlus HTC chimney pipe horizontally within the Wall Thimble. Must extend minimum 2 into the room. 14⅛ 12⅜ 7¾ 8 6½ C9043 C9143 C9243 EXTENSION C9043-EXT WLL THICKNESS INSTLL PIPE SECTION Up to 3 One 6 section Two 6 section One 12 sections One 12 section and one 6 section Combustion ir Wall Thimble Ø Use with Combustion ir System components. Delivers outdoor air as combustion air to the appliance. Operates as a direct vent system without requiring a second penetration to the building envelope. lack. Patent-pending. SIZE CS-WTHTC 8CS-WTHTC Tee w/ Cap Use for through-the-wall chimney installations. The Tee Cap is removable for easy chimney cleaning or inspection. Tees are also available in kits. C C C9067SS C9167SS C9267SS 69 DuraVent

11 ll-fuel Chimney DuraPlus HTC djustable Tee Support racket Ø dj. 2"-6" C Required to support the Tee; suspended from a wall. Supports up to 25 of DuraPlus HTC Chimney. n additional Re-Support racket can be used for heights up to 50'. ttaches to pipe above or below tee. Triangular bracket may be inverted. djustable base provides 2-6 clearance to wall. Tee Support racket is included in Tee Kit C C9074 C9174 C9274 Re-Support racket 1" Can be used for a Tee or intermediate Re-Support system, or above and offset. Will support up to 25. djustable 2-6. dapters included for 7 and 8 chimney. 1" " C9979 Universal djustable Wall Strap 2 For use in interior or exterior installation to stabalize chimney while ensuring a 2 clearance. Wall straps are required every 8 on a vertical wall of the building. dapters included for 7 and 8 chimney C9968 Universal Extended Wall Support *new part* Use to provide an installation above the tee and will pass by obstructions or overhangs. Supports up to 25 of chimney and has an adjustment of 12. dapters included for 7 and 8 chimney C DuraVent 70

12 DuraPlus HTC ll-fuel Chimney Firestop Radiation Shield 17 14½ Use in ceiling/floor penetrations when a ceiling support is not used. Not required when passing through the roof. Fits on underside of ceiling and adjusts to cover framing. 3¾ Ø 17 14½ 16 SIZE C9144 C9244 Reduced Clearance Firestop Radiation Shield 16 1 min 16 Use in ceiling/floor penetrations when a ceiling support is not used. Required for use at ceiling levels in multi-story applications. Fits on underside of ceiling and adjusts to cover framing. SIZE 6 C ttic Insulation Shield C C 10"-24 Required in all installations that pass through an attic to prevent insulation and debris from accumulating near the chimney, unless chimney is enclosed in a chase. Consists of three parts: a collar, a base, and an adjustable sleeve. djusts from in height. Fits 6-8 diameters. SIZE , 11, ¼ C 20 C9946 DuraPlus ttic Insulation Shield Roof Radiation Shield Ø 15 Required where a chimney passes through the roof. Pre-punched holes for adjustment to roof pitch C9089 C9189 C9289 R OOF R DI TION SHIEL D 71 DuraVent

13 ll-fuel Chimney DuraPlus HTC Roof Flashing Use to weather proof the penetration of chimney pipe through the roof. Storm Collar required. Select roof flashing based on pitch of roof. For example, a 6/12 pitch has a vertical rise of 6 over a horizontal distance of 12. Made of galvalume. D FLT RooF C D C9051 C9151 C9251 C /12-6/12 PITCH C D C9049 C9149 C9249 7/12-12/12 C9050 C9150 C /12-18/12 C9081 C9181 C /12-24/12 C9052 C9152 C9252 DS Roof Flashings Use with metal or tile roofs. vailable in sizes 6 and 8 in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of dead soft aluminum. Refer to Roof Flashing table for dimensions. SIZE 6 8 FLT Roof C9051DS C9251DS 0/12-6/12 C9049DS C9249DS 7/12-12/12 C9050DS C9250DS Universal Extended Roof racket Use to support the chimney when it extends more than 4 above the roof. Provides stability to chimney against wind and snow. Mounting brackets and adjustable tubing included. dapters included for 7 and 8 chimney. PPROX. 60 djusts 67"-114" C DuraVent 72

14 DuraPlus HTC ll-fuel Chimney Storm Collar Required with DuraPlus HTC flashing to create a weather proof penetration through the roof line. Seal inner edge of the collar to the chimney pipe with non-hardening 500 F high-temperature sealant. Made of aluminum C9959 Universal Oversized Storm Collar 8 Ø Ø Use to provide cover for extreme weather conditions C9947 Chimney Cap Ø Required where pipe terminates above the roof line. Removable screws allow for cleaning of the chimney and spark arrestor screen. Made of stainless steel C9084 C9184 C9284 ase Plate Use ase Plate to connect DuraPlus HTC directly to a zeroclearance fireplace C9001 C9101 C /16 73 DuraVent

15 ll-fuel Chimney DuraPlus HTC Transition nchor Plate C Ø Ø D 17/16 Use Transition nchor Plate with DuraPlus HTC when extending or converting from DuraLiner to DuraPlus HTC in chimney restoration. Use with DuraLiner Slip Connector and Hanger. (See DuraLiner section.) SIZE C D 6 C C C9040D C C C9240D Soffit/Overhang Trim Plate C Ø Use when the chimney penetrates through an exterior eve or soffit. Trim Plate provides a clean installation through the underside of a soffit without the need for a field-fabricated cover. Not for use as a firestop C C9031 C911 C9231 Chase ir Intake w/ Rodent Guard llows required ventilation air into chase. Screen keeps rodents out. SIZE Snow Splitter Use to divert snow around chimney, vent, and roof flashing. Constructed of paintable galvanized material. Ships flat for easy assembly C DuraVent 74

16 DuraPlus HTC ll-fuel Chimney Offset Chart OFFSET RISE Elbow Degrees SIZE 6" DIMETER 7" DIMETER 8" DIMETER Chimney Section Offset Inches Rise Inches Offset Inches Rise Inches Offset Inches Rise Inches Chimney Sizing Chart For Fireplace Installations CHIMNEY HEIGHT (FEET) 50 T T FIREPLCE OPENING (INCHES) W WIDTH H HEIGHT 6 H W Dotted line represents sample problem. Example shows fireplace opening as 36 wide and 30 high, and the chimney height as 20. The correct flue size for the sample problem is 12 diameter pipe. 75 DuraVent

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to

More information

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604. DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60. DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation

More information

PelletVent Multi-fuel venting system. UL 641.

PelletVent Multi-fuel venting system. UL 641. PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441. PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.

More information

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent

More information

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA

More information

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

5x 8 DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION 5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting

More information

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson

More information

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation

More information

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED

More information

Bring In the Fresh Air

Bring In the Fresh Air ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the

More information

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions Shasta Vent Inc All-Fuel HT Chimney Installation Instructions August 2015 v1.02 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

BDM Direct Vent systems are for use with direct vent gas fired appliances.

BDM Direct Vent systems are for use with direct vent gas fired appliances. INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.

More information

ULC S636 System. PolyPro. PolyPro Flex. Terminations

ULC S636 System. PolyPro. PolyPro Flex. Terminations PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene

More information

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications

More information

VP Pellet Pipe. For pellet burning stoves. FEATURES

VP Pellet Pipe. For pellet burning stoves. FEATURES CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"

More information

Ventis Direct Vent. Installation Instructions

Ventis Direct Vent. Installation Instructions entis Direct ent Installation Instructions A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES), TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPRORTANCE THAT

More information

MODEL CF CEILING SUPPORTED CHIMNEY

MODEL CF CEILING SUPPORTED CHIMNEY Manufactured by Selkirk Canada Corp. - Hamilton, Ontario Installation Instructions for MODEL CF CEILING SUPPORTED CHIMNEY Round Top Storm Collar Flashing Attic Insulation Shield/Firestop Spacer Intermediate

More information

DURAVENT POLYPRO VENTING PRODUCTS

DURAVENT POLYPRO VENTING PRODUCTS DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12

More information

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications

More information

Pellet Stove. Flex Pipe. Appliance Connector

Pellet Stove. Flex Pipe. Appliance Connector Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel

More information

VENT SYSTEM COMPONENTS

VENT SYSTEM COMPONENTS Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances

More information

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. Malm Fireplaces, Inc. 368 Yolanda Avenue - Santa Rosa, Ca 95404 (707) 523-7755 - Fax: (707) 571-8036 info@malmfireplaces.com 34 Zircon Direct Vent Tested & Listed by LabTest Certified for use in USA &

More information

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness Venting Vent Material This unit is approved for installation using 4 x 6-5/8 in co-axial direct vent pipe and accessories manufactured by Simpson Dura-Vent. Follow the installation instructions supplied

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS DISTRIBUTED BY: SBI VENTING DIVISION 2100 insulated chimney All-Fuel Chimney System INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIRSPACES)

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

Mitchell Metal Products, Inc.

Mitchell Metal Products, Inc. Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the

More information

DuraTech. Installation Instructions. Combustion Air System

DuraTech. Installation Instructions. Combustion Air System Installation Instructions Combustion Air System Combustion Air System (CAS) brings in outside air for wood-burning appliances. Used with the DuraTech chimney system. DuraTech A MAJOR CAUSE OF CHIMNEY RELATED

More information

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY. CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN

More information

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP) Installation Instructions PelletVent Pro (PVP) PelletVent Factory-Built Chimney Relining A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition

More information

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro Installation Instructions Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13 Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

Type B Gas Vent. Installation Instructions

Type B Gas Vent. Installation Instructions Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type

More information

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system CTLOG Direct Vent System for PELLET STOVES Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system Direct-Temp for pellet stoves is the revolutionary, high-performance

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

Pellet Vent INSTALLATION INSTRUCTIONS

Pellet Vent INSTALLATION INSTRUCTIONS Pellet Vent INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS PELLET

More information

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 42" WOODBURNING FIREBOX Model C42EC2 Circulating (Louvered) INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,

More information

VERTICAL POWER VENT KIT

VERTICAL POWER VENT KIT INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas

More information

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.

More information

X-593 SOLID FUEL HEATING QUESTIONNAIRE

X-593 SOLID FUEL HEATING QUESTIONNAIRE X-593 SOLID FUEL HEATING QUESTIONNAIRE CLEAR PHOTOGRAPHS & QUESTIONNAIRE REQUIRED FOR EACH INSTALLATION (UNITS & VENTS) NAME ADDRESS PHONE NO POLICY NO BROKER INSPECTED BY DATE GENERAL INSTALLATION QUESTIONS

More information

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL SWB4I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL The SWB4I fireplace is an insulated radiant wood burning fireplace with a 6-inch wide front opening. It comes

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D. Typical Installations 0 8 9 Vertical Installation. Vertical Termination ap. Storm ollar. Flashing. Roof Support. Length. ttic Radiation Shield. Firestop 8. ecorative lack Plate 9. Length (lack) 0. Insulation

More information

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible

More information

Twin Wall Installation Instructions And Maintenance Guide

Twin Wall Installation Instructions And Maintenance Guide Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate

More information

Inspection Checklist Mechanical Final

Inspection Checklist Mechanical Final Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and

More information

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,

More information

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009. SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for

More information

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT

More information

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX flexible venting simply perfect cost efficient convenient durable Est. 1990 FLEX FREEDOM VENTING Introduction Freedom Flex Venting systems are top of the line when it comes to materials, cost efficiency

More information

Pellet Vent INSTALLATION INSTRUCTIONS

Pellet Vent INSTALLATION INSTRUCTIONS Pellet Vent INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS PELLET

More information

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 P Rev. C 06/2014 INSTALLATION INSTRUCTIONS FOR PIPE REDUCER AND ALL ASSOCIATED SV4 (4") SECURE VENT/DIRECT VENT COMPONENTS INCLUDING SV4CGV-1 VERTICAL

More information

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS Selkirk LLC Selkirk LLC Research & Development State Route 93 North & Sutton Road P.O. Box 631 Logan, OH 43138 9/21/2006 TO: Our Valued Customers FROM: Glen Edgar Director R&D SUBJECT: SELKIRK MODEL DT

More information

EUTECTIC EC-10DV Series

EUTECTIC EC-10DV Series EUTECTIC EC-10DV Series DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL VENTING INSTALLATION INSTRUCTIONS CONTENTS..........................................PAGE Basic Guidelines..........................................1

More information

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10 Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)

More information

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH Applies to: Form I-PDH-V Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Power-Vent Indoor Model PDH General

More information

Peninsula woodburning fireplace. Models (V)PN36-A

Peninsula woodburning fireplace. Models (V)PN36-A Peninsula woodburning fireplace OWNER S OPERATION AND INSTALLATION MANUAL ICC-ES #ESR-2542 Models (V)PN36-A SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain

More information

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS

More information

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...

More information

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.

This firebox meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions. 36" See Through Smooth Face wood burning fireplace OWNER S INSTALLATION MANUAL 368STM with Brushed Brass Finish Doors 368STM-1 with Platinum Finish Doors Includes Combustion Air Kit and Bi-Fold Doors CPFS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (V) (V)C36 36 smooth face (V)C36I 36 smooth face with insulation (V)C36H 36 smooth face with insulation & Herringbone refractory (V)C36L, CWC36C 36 circulating (V)C36LI 36 circulating with insulation (V)C36LH

More information

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Westport B Y : S H E R W O O D I N D U S T R

More information

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40 TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS PENINSULA MODEL VPN36 3-SIDED, WOODBURNING FIREBOX INSTALLATION AND OPERATING INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,

More information

SEPARATED COMBUSTION. General WARNING

SEPARATED COMBUSTION. General WARNING Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and

More information

P P Gas Fireplace. P See Thru

P P Gas Fireplace. P See Thru P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)

More information

SEPARATED COMBUSTION WARNING

SEPARATED COMBUSTION WARNING CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Form I-SDH-V (Version.5) Obsoletes I-SDH-V (Version.4) Vent Installation Applies to: Venting Requirements for PREEVA Separated-Combustion

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

36" and 42" WOOD BURNING FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS

36 and 42 WOOD BURNING FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS 6" and 4" WOOD BURNING FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS Glass Doors, Fan Assembly, and Outside Combustion Air Kit Available MODELS: BWB4A BWB4IA BWBC4A BWBC4IA BWB5A BWB5IA BWBC5A BWBC5IA

More information

ZC Kit AGP Pellet Insert

ZC Kit AGP Pellet Insert ZC Kit AGP Pellet Insert Compatibility AGP Pellet Insert Lopi AGP Pellet Insert Overview Packing List ZC Can Rear Panel ZC Can Top/Side Panel Bottom Panel (Fiber Board with Steel) (40) # 8 x 3/8 Type A

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (V) (V)C42 42 smooth face (V)C42I 42 smooth face with insulation (V)C42H 42 smooth face with insulation & Herringbone refractory (V)C42L, CWC42C 42 circulating (V)C42LI 42 circulating with insulation (V)C42LH

More information

FACTORY-BUILT FIREPLACE MODEL OWNER S MANUAL - INSTALLATION - OPERATION

FACTORY-BUILT FIREPLACE MODEL OWNER S MANUAL - INSTALLATION - OPERATION FACTORY-BUILT FIREPLACE MODEL OPUS Tested and certified by Intertek UL 127-1999 ULC-S610-M87 R-94 OWNER S MANUAL - INSTALLATION - OPERATION Keep these instructions for future use. Manufactured by: 3594

More information

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual RETIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Part # 461006 MODEL PVF INDIRECT GS FIRED FURNCES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual Model PVF, Indirect Gas Furnace,

More information

This wood burning fireplace complies with UL127- CAN/ULC-S610-M87 standard as a FACTORY BUILT APPLIANCE.

This wood burning fireplace complies with UL127- CAN/ULC-S610-M87 standard as a FACTORY BUILT APPLIANCE. RESIDENTIAL AND OUTDOOR WOOD BURNING FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS (V)S42 SERIES SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For

More information

CHIMNEY INSTALLATION. Technical Bulletin #1

CHIMNEY INSTALLATION. Technical Bulletin #1 Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe

More information

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

MODELS (V)C42, (V)C42I, (V)C42H, (V)C42L, (V)C42LI, (V)C42LH AND CWC42C

MODELS (V)C42, (V)C42I, (V)C42H, (V)C42L, (V)C42LI, (V)C42LH AND CWC42C WOOD BURNING FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS (V)C42, (V)C42I, (V)C42H, (V)C42L, (V)C42LI, (V)C42LH AND CWC42C SAVE THIS BOOK This book is valuable. In addition to instructing

More information

MODELS (V)C36, (V)C36I, (V)C36H, (V)C36L, (V)C36LI, (V)C36LH AND CWC36C

MODELS (V)C36, (V)C36I, (V)C36H, (V)C36L, (V)C36LI, (V)C36LH AND CWC36C WOOD BURNING FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS (V)C36, (V)C36I, (V)C36H, (V)C36L, (V)C36LI, (V)C36LH AND CWC36C SAVE THIS BOOK This book is valuable. In addition to instructing

More information

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Vertical Termination Part No: 3CGRVT 16 7/8 18 Vent Pipe Extension Part No: 3CG18 9 7/8 Wall Hanger Part No: 3CGWH 7 7/8 7 3/8 Corr/Guard Direct Vent Water Heater Vent/Air Intake System Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and

More information