1 Heat recovery units -W-450 Dimensions Elementy dachowe Description The -W-450 heat recovery unit is designed for single-family houses up to 200 m 2 in usable floor area Key performance features: Maximum heat recovery ratio 90.5%, tested as per EN 308 by TÜV SÜD Plastic counter-flow heat exchanger Automatic air flow bypass Freeze protection Modbus connectivity: all unit control functions can be managed via a PC or a central automation system Preheater and secondary heater control connectivity Programmable week control timer Filter clogging indicator Class EU4 filters in standard (class F7 filters available on request) Supported sensor typees: CO 2, RH, and a pressure switch Wall-mounted or free-standing Various duct connection versions available: EA, SA, OA, RA Metal duct connections with EPDM gaskets for air tightness class D EBM PAPST energy-efficient fans Control * All All measurement dimensions are values in mm. are mm. When ordering, specify the control type. There are two versions of control available - wired and wireless: -W with a wired controller -W-450W - with Wi-Fi control 1 Control 1 Air supply & exhaust filters Bypass Counter-flow heat exchanger Housing Air supply & exhaust fan ALNOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone. 685

2 Heat recovery units -W-450 Technical specifications -W-450 Air flow rate (m 3 /h) * 470 Rated power supply (V/Hz/Ph) 230 / 50 / Maximum power consumption (W) 180 Maximum current consumption (A) 1.54 Maximum sound pressure level (db (A)) ** 48 Weight (kg) 41 Filters * The static pressure is 0 Pa. ** Measured at 1.5 m away from the unit. Class G4 filter as per EN 779 (class F filter available on request) The total power consumption is measured as the consumption by two (air supply and air exhaust) fans. The Specific Fan Power is expressed in kw/m 3 /s as per EN (Ventilation for non-residential buildings). SFP: Specific Fan Power Performance curve Total SFP = Całkowity powet consumption pobór mocy (kw) Przepływ Airflow powietrza (m 3 /s) (m 3 /s) Static External pressure Pressure (Pa) (Pa) Low speed Speed Medium speed Speed High speed Speed Boost Air flow rate (m 3 /h) Air Volume (m 3 /h)

3 Heat recovery units -W-450 Technical specifications Sound level chart Speed Octave Sound Pressure Level (db: Overall A Scale ) db(a) Sound pressure Hz Speed boost High speed Medium speed Low speed Octave sound pressure level (db: general A) NR10 NR Hz Central Frequency (Cycle per Second) Low Speed Low speed Medium Speed Medium speed NR20 NR30 NR50 NR40 High Speed Boost Medium speed Boost 687

4 Heat recovery units -W-450 Technical specifications Air tightness test The nominal air flow rate of the unit is 400m 3 /h. The following table lists the internal and external air leak rates and percentage vs. the overall air flow rate: Test No. P stst (Pa) Air leak rate (m 3 /h) Inner air leak Percentage ratio (%) Air leak rate (m 3 /h) Outer air leak Percentage ratio (%) Thermodynamic test The following temperature coefficients were measured for the -W-450 heat recovery unit: Air supply rate [m 3 /h] Air exhaust rate [m 3 /h] Temp. coeff. (air supply) eta tsup [%] Humidity coeff. (air supply) eta tsup [%] Temp. coeff. (air exhaust) eta teha [%] Humidity coeff. (air exhaust) eta teha [%] Mean temp. coefficient eta tepb [%]

5 Heat recovery units -W-450 Energy class -W-450 A 57 db 450 m 3 /h ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI /

6 Heat recovery unit controller manual controller HRU-MinistCONT-Man Function Description Availability Fan speed control Fan speed boost Filter clogging indicator Automatic air flow bypass Electric heater control Sensor (VOD) Sensor (Humidity) Freeze protection Preheater control BMS connectivity Modbus connectivity Programmable week control timer Air supply and air exhaust fans are provided with a 3-speed control system. This function increases the fan speed: Option 1: Press the BOOST button on the control panel Option 2: Activated with an external dry relay input or an external 230 V input (activated e.g. by a lamp switch in the kitchen, bathroom, etc.) on the controller s PCB. Two filter clogging indicator options: Option 1: The filter clogging indicator counts down the unit's operating time to a preset value. When the preset value is reached, a filter change request indicator is activated on the control panel. Option 2: Filter clogging can be monitored with a pressure switch. When the filter reaches the clogging limit, the pressure switch activates a filter change request indicator on the control panel. The filtered fresh air is supplied indoors, bypassing the heat exchanger. The interfaced electric heater can have the output automatically switched between a maximum of 2 levels the selection of which depends on the desired temperature setting and the actual indoor temperature. The fans are operated continuously by the control output of a CO2 sensor or an air quality sensor. The fans are operated continuously by the control output of an indoor air humidity sensor. If the outdoor temperature is low, the freeze protection function is activated to protect the heat exchanger from freezing. If the outdoor temperature is low, the fresh air supply is treated by a preheater upstream of the unit. This function protects the heat exchanger from freezing. IN: The unit can be turned on and off using an external control panel. OUT 1: Unit status output OUT 2: Unit fault alarm output This feature allows operating all controls of the unit via a PC or a central automation system. The unit can be programmed to operate at specific hours in a weekly cycle. 3 speeds (all fans) (High / Medium / Low) Optional Optional Optional Data logging This function allows logging all available operating options of the unit. Fire mode This function activates a special operating status in the case of a fire alarm. Alarms - Filter change required - Fan failure - Preheater failure - Heater failure (Error code display) Child lock Locks the control keypad to prevent inadvertent operation. 690

7 Heat recovery unit controller HRU-MinistCONT-WiFi controller Kontroler HRU-MinistCONT-WiFi umożliwia zdalne starowanie centralami rekuperacyjnymi z serii HRU-MinistAIR - oznacza to, że z dowolnego miejsca na świecie możesz wybrać rodzaj trybu pracy centrali rekuperacyjnej odpowiadający Twoim aktualnym potrzebom w zakresie jej funkcjonowania. Wraz z zakupem centali, dokupując HRU-MinistCONT-WiFi otrzymujesz zainstalowaną puszkę sterującą wraz z adresem internetowym oraz danymi do zalogowania się i obsługiwania zdalnie Twojej centrali. Function Description Availability Fan speed control Fan speed boost Filter clogging indicator Automatic air flow bypass Electric heater control Sensor (VOD) Sensor (Humidity) Freeze protection Preheater control BMS connectivity Modbus connectivity Programmable week control timer Air supply and air exhaust fans are provided with a 3-speed control system. This function increases the fan speed: Option 1: Press the BOOST button on the control panel Option 2: Activated with an external dry relay input or an external 230 V input (activated e.g. by a lamp switch in the kitchen, bathroom, etc.) on the controller s PCB. Two filter clogging indicator options: Option 1: The filter clogging indicator counts down the unit's operating time to a preset value. When the preset value is reached, a filter change request indicator is activated on the control panel. Option 2: Filter clogging can be monitored with a pressure switch. When the filter reaches the clogging limit, the pressure switch activates a filter change request indicator on the control panel. The filtered fresh air is supplied indoors, bypassing the heat exchanger. The interfaced electric heater can have the output automatically switched between a maximum of 2 levels the selection of which depends on the desired temperature setting and the actual indoor temperature. The fans are operated continuously by the control output of a CO2 sensor or an air quality sensor. The fans are operated continuously by the control output of an indoor air humidity sensor. If the outdoor temperature is low, the freeze protection function is activated to protect the heat exchanger from freezing. If the outdoor temperature is low, the fresh air supply is treated by a preheater upstream of the unit. This function protects the heat exchanger from freezing. IN: The unit can be turned on and off using an external control panel. OUT 1: Unit status output OUT 2: Unit fault alarm output This feature allows operating all controls of the unit via a PC or a central automation system. The unit can be programmed to operate at specific hours in a weekly cycle. 3 speeds (all fans) (High / Medium / Low) Optional Optional Optional Data logging This function allows logging all available operating options of the unit. Fire mode This function activates a special operating status in the case of a fire alarm. Alarms - Filter change required - Fan failure - Preheater failure - Heater failure (Error code display) Child lock Locks the control keypad to prevent inadvertent operation. 691

8 Heat recovery unit controller HRU-MinistCONT-Wifi Controller Login panel: All users receive their personal user names and passwords for remote access to the device they purchase. Alnor ventilation controller configuration pane: The wizard's steps guide the user through the commissioning and local network configuration of the device. Heat recovery unit start and stop: ON / OFF 692

9 Heat recovery unit controller HRU-MinistCONT-Wifi Controller Heat recovery unit work mode selection: adjust the continuous operation of the unit to your needs, or use the predefined options as follows: STANDARD MODE: continuous air change. Enables work mode selection for the AIR SUPPLY fan and the AIR EXHAUST fan. AIR EXHAUST MODE: controls the air exhaust fan only. Fan work modes: speed 1, 2, 3 or OFF. Start the function to extract stale air from the area and return to the air change mode by selecting STANDARD. 693

10 Heat recovery unit controller HRU-MinistCONT-Wifi Controller AIR SUPPLY MODE: controls the air supply fan only. Fan work modes: speed 1, 2, 3 or OFF. Start the function to supply fresh air indoors and return to the air change mode by selecting STANDARD. VOD MODE: in the Ventilation On Demand mode, the air supply and air exhaust rates depend on the humidity readout from the optional indoor air humidity sensor connected to the heat recovery unit. The sensor is sold separately. Remote temperature setting: choose the indoor temperature for the room. Indoor air temperature: shows the actual temperature of the air exhausted from the area, which is changed by the controller via the heat recovery system to match the remote temperature setting. The outdoor air intake temperature. The temperature of the air supplied by the heat recovery unit to the area. 694 Alarm code: displays the error code of the heat recovery unit. (See the error code definitions in the User Manual.) BY-PASS FUNCTION: the heat recovery unit supplies fresh and filtered outdoor air bypassing the heat exchanger. When this indicator is checked, the By-Pass Mode is running. ONLINE: shows the status of the data connection between the controller and the heat recovery unit. When this indicator is lit, the data connection is correct.

11 Heat recovery unit accessories F7 filter EU4 filter EU7 (F7) filter elements are fine filters with the rated separation efficiency at 80 90% for 0,4 µm particulates. Product code Filter class Dimensions (mm) HRF-Mair-250-F7 F7 150x360x30 HRF-Mair-400-F7 F7 215x605x45 Product code Filter class Dimensions (mm) HRF-Mair-250-EU4 EU4 150x360 HRF-Mair-400-EU4 EU4 215x605 Humidity sensors An air humidity sensor can operate a heat recovery unit by regulating the air fan speed via its output signals. The air fan is switched between three 3 speeds which correspond to air humidity presets. H7015B1060 duct air humidity sensor Maintenance-free and automatic humidity and temperature measurement Power supply Humidity measurement range Output signal Temperature measurement range Protection rating Wiring length 24 V 0 to 100% RH 1 to 10 V 0 to +50 C IP m 695

12 Heat recovery unit accessories T7560C1006 room air humidity sensor CO 2 sensors Automatic humidity and temperature measurement Power supply Humidity measurement range Output signal Temperature measurement range Protection rating Sensor typee CO 2 (carbon dioxide) sensors allow regulating -W-450 heat recovery units according to the indoor or duct CO 2 concentration levels (depending on where the sensor is installed). 24 V 10 to 95% RH 1 to 10 V +6 to +40 C IP30 20 kω NTC AQS71-KAM-T duct CO 2 sensor Maintenance and calibration free Power supply Test Measurement accuracy Temperature measurement range Output signal 24 V 0 to 2000 ppm +/- 50 ppm 0 to +50 C 1 to 10 V C7110D1009A room CO 2 sensor Automatic humidity and temperature measurement Self-calibration algorithm Power supply Test Measurement accuracy Temperature measurement range Output signal Sensor typee 24 V 0 to 3000 ppm +/- 50 ppm 0 to +50 C 1 to 10 V 20 kω NTC 696

HRU-MinistAir-W-250. Equipment & accessories. Heat recovery units. Dimensions. Description

HRU-MinistAir-W-250. Equipment & accessories.   Heat recovery units. Dimensions. Description Heat recovery units Description www.alnor.com.pl Dimensions Ø 125 600 660 702 Podręcznik użytkownika rekuperatorów is the smallest heat recovery unit in the range of MinistAIR products. With a total air

More information

Auxiliary Equipment and Accessories

Auxiliary Equipment and Accessories http://www.ventilation-alnor.co.uk/index/products_en/heat-recovery-%e2%80%93-air-handling-units/ Description is recommended for use in residential houses with max. area of 200m2. The most important key

More information

Heat and energy recovery ventilators

Heat and energy recovery ventilators Description is recommended for use in residential houses with max. area of 200m2. The most important key features of : Heat recovery up to 95% according to EN 308 - TUV SUD Plastic counterflow heat exchanger

More information

User manual for HRU-MinistAir-W-450 heat recovery units. Wi-Fi control for the HRU-MinistAir-W-450 heat recovery unit

User manual for HRU-MinistAir-W-450 heat recovery units. Wi-Fi control for the HRU-MinistAir-W-450 heat recovery unit User manual Wi-Fi User manual for HRU-MinistAir-W-450 heat recovery units Wi-Fi control for the HRU-MinistAir-W-450 heat recovery unit HRU-MinistCONT-WiFi 1 500 450 400 350 300 250 200 150 100 50 0 0

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION Swegon CASA W130 Ventilation unit with counter-flow plate heat exchanger Ventilation unit for residential houses under 250 m². The unit has counter-flow plate heat exchanger. Suitable also for renovation

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h PRODUCT DATA COMFORT 302 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 345 m 3 /h COMFORT 302 TOP Product description The Comfort 302 Top is an energy efficient

More information

Energy recovery unit. Projection documents

Energy recovery unit. Projection documents Energy recovery unit Projection documents 1. Technical charakteristics 1.1. Function and uses The energy recovery unit Futura is a device designed for controlled ventilation and interior adjustment of

More information

TSEK VHR EC HEAT RECOVERY UNITS

TSEK VHR EC HEAT RECOVERY UNITS TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

TEVHR. Heat Recovery Ventilator

TEVHR. Heat Recovery Ventilator TEVHR Heat Recovery Ventilator Contents Teknogen Who we are, what we do? TEVHR... 1 Unit Specifications... 2 Performance Data... 3 Technical Specification... 5 Components... 6 Dimensions... 7 Duct Connection

More information

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION

More information

Manual. Document ENG

Manual. Document ENG Models Vallox TSK Multi 50 MV Vallox TSK Multi 50 MV EH Vallox TSK Multi 80 MV Vallox TSK Multi 80 MV EH Vallox TSK Multi 80 MV EHX (EH = post-heating) (EHX= post-heating and additional heating) Document

More information

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25 Residential Heat Recovery Ventilation REHVA European Guidebook No 25 REHVA European Guidebook No 25 2 Limited to mechanical supply and exhaust ventilation Targeted to engineers, HVAC consultants and contractors

More information

MODEL: BV400 Part No:

MODEL: BV400 Part No: MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...

More information

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation 300/400/450 180 Renovent Excellent 180, 300, 400 and 450 Silent and energy-efficient ventilation Central ventilation The Renovent Excellent is a mechanical

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Sentinel Demand Energy Recovery Ventilation

Sentinel Demand Energy Recovery Ventilation Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

Residential-Use Lossnay

Residential-Use Lossnay HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation

More information

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

Healthy, comfortable and energy-efficient ventilation

Healthy, comfortable and energy-efficient ventilation Healthy, comfortable and energy-efficient ventilation partner Renovent Excellent 180, 300 and 400 Silent and energy-efficient ventilation 300/400 180 Central ventilation The Renovent Excellent is a mechanical

More information

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production COMPACT S Product description

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment...

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system Comfort air conditioning 56/58 Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system 58 3 0 - simplified illustration Automatically selects the most economical

More information

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger Ceiling-mounted ventilation unit with plate heat exchanger Ventilation unit with plate heat exchanger for commercial applications. Well-suited for both newly constructed buildings and renovation projects

More information

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018 New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department

More information

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent

More information

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM VENTILATION. for schools and public spaces SINGLE-ROOM VENTILATION for schools and public spaces Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated,

More information

Heat recovery unit. Installation Manual

Heat recovery unit. Installation Manual Heat recovery unit Installation Manual TABLE OF CONTENTS Introduction... 2 1. Identification and application... 2 2. Safety instructions... 2 3. Technical specifications...3 4. Installation...4 4.1. Connection

More information

Heat Recovery Ventilation

Heat Recovery Ventilation Service Manual Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM 350FAVE VAM 500FAVE VAM 650FAVE VAM 800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE Heat Recovery Ventilation VAM 150FAVE VAM 250FAVE VAM

More information

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation DEMAND-CONTROLLED HOME VENTILATION No more worrying about the indoor climate The indoor climate must be taken seriously

More information

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 62 26 01 - simplified illustration Automatically selects the most economical operating mode! 62 and 66 AIR OLUME FLOW:

More information

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R85 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 170 m 2. The unit is equipped with rotary heat exchanger.

More information

HRV Brochure. Heat Recovery Ventilation

HRV Brochure. Heat Recovery Ventilation HRV Brochure Heat Recovery Ventilation The Importance of Ventilation In todays hi tech world, ventilation is more important than ever before. Gone are the days when we relied on natural ventilation with

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş. FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit is a registered trademark of Doğu İklimlendirme A.Ş. Plastic Spigot F7 Filter Counter Flow Heat Recovery Exchanger Control Box Plastic Spigot

More information

Ventilation Unit Zehnder ComfoAir 350

Ventilation Unit Zehnder ComfoAir 350 Use The ComfoAir 350 ventilation unit was developed for residential and small commercial buildings. It combines maximum comfort, simple operation and very high efficiency. The CA350 moves up to 218 cfm

More information

Package Hygienic Air Handling Units. PHK Series

Package Hygienic Air Handling Units. PHK Series Package Hygienic Air Handling Units PHK Series 1 PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

PRODUCT RANGE: ROOFTOP PACKAGE

PRODUCT RANGE: ROOFTOP PACKAGE Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They

More information

Indirect Evaporative Air Conditioning

Indirect Evaporative Air Conditioning Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient

More information

Technical Information HXV - HRV Ventilation

Technical Information HXV - HRV Ventilation Technical Information HXV - HRV Ventilation General description Technical data Accessories VENTILATION HXV 5 1 General description 1.01-1.02 2 Technical data 2.01-2.02 3 Accessories 3.01-3.03 HRV 5 4 General

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific

More information

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0 Residential/commercial units selection program: http://salda.lt/en/selection/ahu AmberAir Compact units selection program VentMaster: http://salda.lt/en/pros/category/download_page/ WWW.SALDA.LT Rotor

More information

Indirect Evaporative Air Conditioning

Indirect Evaporative Air Conditioning Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient

More information

VENTILATION WITH HEAT RECOVERY

VENTILATION WITH HEAT RECOVERY H C V 3 0 0-4 0 0-5 0 0-7 0 0 & H CC 2 TA K E C O N T R O L O F T H E I N D O O R C L I M AT E W I T H M E C H A N I C A L V E N T I L AT I O N W I T H H E AT R E C O V E R Y VENTILATION WITH HEAT RECOVERY

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

250mm dia straight pipe length SP4 SP3. Air volume

250mm dia straight pipe length SP4 SP3. Air volume MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material

More information

CI/SfB (57.7) 2nd edition

CI/SfB (57.7) 2nd edition CI/SfB (57.7) 2nd edition Sentinel Totus D-ERV Range Following on from the highly successful award winning Sentinel demand ventilation system, Vent-Axia has taken the next step by incorporating the Sentinel

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units. AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and

More information

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m Swegon CASA R120 Instructions for installation, operation and maintenance R120_h_EN-m Content Instructions for Use For the user Important information... 3 Control from a Premium control panel... 4 Control

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT... 3 Performance Data... 4 Performance Table... 5 General description... 6 Fan Chart-explanation

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units C2 and UNI 2, 3,4 Flexit handling units C2 and UNI 2, 3,4 energy efficient ventilation for a healthy indoor environment A FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit C2 and UNI 2, 3, 4 The handling

More information

R E P O R T D I N E N

R E P O R T D I N E N R E P O R T W R G 3 9 6 D I N E N 1 3 1 4 1-7 Test laboratory Test object Customer Scope of assignment TÜV SÜD Industrie Service GmbH Center of Competence for Refrigeration and Air Conditioning Air Conditioning

More information

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger.

More information

Flexit air handling units UNI 2, 3 og 4

Flexit air handling units UNI 2, 3 og 4 Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Control System Structure

Control System Structure Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient

More information

Whole Home Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay

More information

The new Xcell EC High Efficiency Range Fresh air pure and simple

The new Xcell EC High Efficiency Range Fresh air pure and simple The new Xcell EC High Efficiency Range Fresh air pure and simple The new Xpelair saving energy, saving money 2 www.xpelair.co.uk Introducing the NEW Xpelair Xcell EC High Efficiency range. The Xcell EC

More information

Heat Recovery Air Handling Units

Heat Recovery Air Handling Units Heat Recovery ir Handling Units OMEKT Heat recovery air handling Units OMEKT 1 KOMFOVENT OMEKT ir Handling Units Komfovent ir Handling units are made to create healthy indoor climate and ensure efficient

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 15 TOP M2 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 400 m 3 /h Comfort heating Comfort cooling VPL 15 TOP M2 Product description VPL 15 Top

More information

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h VENTILATION equipment VENTILATION equipment content DOMEKT Residential ventilation units 50 1 000 m³/h 15 VERSO Non residential ventilation units 1000 34 000 m³/h 61 Domekt R 17 Domekt R 200 V 19 Domekt

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073Q.doc Sentinel Kinetic MVHR and Kinetic Plus MVHR Operation & Monitoring Stock Ref. N 438222 Kinetic B 438222A Kinetic BS 443319 Kinetic

More information

Ventilation Product range ADVANCE ECO 4 ECO 2

Ventilation Product range ADVANCE ECO 4 ECO 2 Product range ADVANCE ECO 4 ECO 2 Air, we breathe it without thinking. Keeping it that way in the modern, airtight homes calls for class-leading ventilation performance and you will find this with the

More information

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW BSK 1/5 RIGHT VIEW TOP VIEW GENERAL SPECIFICATIONS Supply Air Flow Return Air Flow Frame Dimensions (mm) 6,000 m³/h 6,000 m³/h 25 steel profile A2608 x H2723 x L4789 Supply Air Velocity Return Air Velocity

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

Sentinel Kinetic MVHR RANGE

Sentinel Kinetic MVHR RANGE V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073 W.doc Sentinel Kinetic MVHR RANGE User Instructions Stock Ref. N 438342 Kinetic V 438222 Kinetic B Right 438222L Kinetic B Left 443319 Kinetic

More information