Min. Mount Height. Min. Mount Height. Length Weight

Size: px
Start display at page:

Download "Min. Mount Height. Min. Mount Height. Length Weight"

Transcription

1 *! ARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. Protect yourself and others by observing all safety information. Retain instructions for future reference. LS Series * For complete installation instructions, see Generic IOM this piece was inserted within. Also available at Project: Date: Location: City: State: Zip: Customer Name: Local Representative: Contractor: Engineer: Address: City: State: Zip: Phone#: Install Date: Serial#: Notes: Table of Contents Page Models 1 arnings 2 Clearances to Combustibles 2 Product Summary 3 Mechanical Instructions 3 Heater Requirements 4 Theory of Operation 4 iring Diagrams 5-7 Flowchart 8-9 Parts Listing Series Kit Contents 12 Commercial Models (Approved for commercial use) Qty. Model # Residential Models (Approved for both commercial and residential use) arranty registration options: 1. Register online at 2. Fill out this page and fax to Detroit Radiant Products Co. 3. Fill out this page and mail a copy to Detroit Radiant Products Co. Min. Mount Height Gas Type U-Tube Combustion Radiant Emitter "Type" Tube Pkg (circle one) BTU's Length Length eight Chamber Tube #1 LS N or LP 25,000 12'-3" N/A 70# 8 ft. Titanium Coated N/A 10-3 Titanium 3 LS N or LP 30,000 12'-3" N/A 70# 8 ft. Titanium Coated N/A 10-3 Titanium 3 LS N or LP 40,000 12'-3" N/A 70# 10 ft. Titanium Coated N/A 10-3 Titanium 3 LS N or LP 40,000 17'-0" N/A 85# 8 ft. Titanium Coated Aluminized 15-3 Titanium 3 LS N or LP 50,000 17'-0" N/A 85# 10 ft. Titanium Coated Aluminized 15-3 Titanium 3 LS N or LP 40,000 22'-0" 13'-0" 100# 8 ft. Titanium Coated Aluminized 20-3 Titanium 3 LS N or LP 50,000 22'-0" 13"-0" 100# 9 ft. Titanium Coated Aluminized 20-3 Titanium 3 LS N or LP 50,000 31'-3" *17'-8" 120# 9 ft. Titanium Coated Aluminized 30-3 Titanium 3 Min. Mount Height Qty. Model # Gas Type (circle one) BTU's Length U-Tube Length eight Combustion Chamber Radiant Emitter Tube "Type" Tube Pkg #1 LS N or LP 25,000 12'-3" N/A 70# 8 ft. Titanium Coated N/A 10-3 Titanium 3 LS N or LP 30,000 12'-3" N/A 70# 8 ft. Titanium Coated N/A 10-3 Titanium 3 LS N or LP 15,000 17'-0" N/A 85# 8 ft. Titanium Coated Aluminized 15-3 Titanium 3 LS N or LP 40,000 22'-0" 13'-0" 100# 8 ft. Titanium Coated Aluminized 20-3 Titanium 3 LS N or LP 50,000 31'-3" *17'-8" 120# 9ft. Titanium Coated Aluminized 30-3 Titanium 3 *Model requires 5EA-Sub accessory package. Printed in U.S.A Detroit Radiant Products Hoover Rd., arren, MI T. (586) F. (586) Form# LIOLS-1M-3/04 (LES) Replaces Form# LIOLS-2M-10/02 Baffle Pieces Baffle Pieces

2 LS Series arnings and Clearances to Combustibles! ARNING! Only certain models are for residential use. Certified under American Gas Association (AGA) requirement for residential radaint tube heaters No Do not use in the home or sleeping quarters.! ARNING! This heater must be installed and serviced by trained gas installation and service personnel only. Read and understand these instructions thoroughly before attempting to install, operate or service this heater. Failure to comply could result in personal injury, asphyxiation, death, fire, and/or property damage. Retain these instructions for future reference.! ARNING! This is not an explosion-proof heater. here there is the possibility of exposure to flammable vapors, consult the local fire marshal, the fire insurance carrier and other authorities for approval of the proposed installation. LS CLEARANCES TO COMBUSTIBLES (IN.) * MODEL. MOUNTING ANGLE SIDE FRONT BEHIND TOP LS (10) - 25,30 0º º /1 side shield 0º /2 side shields 0º ft from burner 0º NA NA NA NA LS (10,15,20) º º /1 side shield 0º /2 side shields 0º ft from burner 0º NA NA NA NA LS (15) º º /1 side shield 0º /2 side shields 0º ft from burner 0º NA NA NA NA LS (20,30) º º /1 side shield 0º /2 side shields 0º ft from burner 0º *See cover page for models certified for residential use. BELO! ARNING! In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats in a conspicuous location.! ARNING! Failure to comply with the stated clearances to combustibles could result in personal injury, death and/or property damage. TOP SIDE SIDE BELO 0º MOUNTING ANGLE TOP FRONT BEHIND TOP FRONT BEHIND BELO 0º /1 SIDE SHIELD TOP SIDE SIDE! ARNING! This heater should be installed so that the minimum clearances to vehicles, as marked on the heater, will be maintained. If vehicle lifts are present, ensure that these clearances will be maintained from the highest raised vehicle. BELO 45º MOUNTING ANGLE BELO 0º /2 SIDE SHIELDS 2

3 LS Series Mechanical Instructions This supplement is designed to address the specifics of the LS Series - See page 12 for specific product features. Product Summary LS Series commercial/residential tube heaters are available from 10 to 30 foot, 25,000 through 50,000 BTU s, natural or LP gas. LS Series are positive pressure, single stage heaters and feature aluminized steel for it s radiant pipes. Specific Mechanical Instructions LS MODELS 25,000 thru 50,000 BTUH IMPORTANT APPROVED VENT PACKAGES Figure 1 3-DSK RTVP-3 Be sure to identify the titanium combustion chamber and place as the first tube section. Do not use the aluminized steel radiant tubing as the first tube (combustion chamber). Radiant Tube Reflector For residential installations it is required that the appliance be vented. Venting must be 3 in. diameter (4 in. diameter for common venting). Refer to the flue venting guidelines, figure 1 and on page 19 of the General Manual. For residential installations mounted below 8 feet, it is required that Protective Guards (part # PG) are installed on heater (see figure 2). Protective Guard (part # PG) Figure 2 LS BAFFLE INSTRUCTIONS ITH TURBULATOR FINS Insert assembled baffles with HEAT Baffle preceeding the PRESSURE Baffles (fig. 1). Allow for turbulator fins so that the key hole is inserted first. All baffles must be placed vertically in the last radiant tube/heat exchanger (fig.2). Figure 1 If the heater is installed with a U or Elbow fitting all baffle must still remain. There may be some instances where the baffle will be cut into two sections. Place as much baffle as possible downstream of the U or Elbow and the remainder of the baffle just before the U or Elbow fitting. 1st 2nd 3rd Key Hole HEAT BAFFLE PRESSURE BAFFLE 3' Figure 2 IMPORTANT: TE FIN DIRECTION & BAFFLE ASSEMBLY 100º 80º TOP VIE LAST RADIANT TUBE Key Hole HEAT BAFFLE Turbulator fins PRESSURE BAFFLE END VIE SIDE VIE CROSS SECTION ITH BAFFLE Figure 3 3

4 LS Series Electrical Requirements 120 Volt - 60 HZ. Hot surface ignition. Starting Current 4.8 Amps. Running Current 1.1 Amps. 24V controls optional (24VAO). Gas Requirements Manifold Pressure Nat. 3.5 LP Minimum Inlet Pressure Nat. 5.0 LP Maximum Inlet Nat LP Ventilation Requirements Residential models must be vented. Consult the generic supplement for venting instructions and unvented operation. For unvented operation (commercial use only), there must be a positive air displacement of at least 4.0 CFM per 1000 BTU/H for natural gas or 4.5 CFM per 1000 BTU/H for LP gas. VE-4 termination cap must also be used. Maximum vent length for all models is 20 ft. Approved & Required Vent Caps Sidewall Single 3 Duravent sidewall vent kit (3-DSK). 3 Vent terminal (SD-3). Sidewall Dual (Sharing common t-stat) 4 Duravent sidewall vent kit (4-DSK). 4 Vent terminal (SD-4). Theory of Operation Starting Circuit hen voltage is applied to L1 and L2 (see diagram on right), a circuit is completed from L1 via the blower motor to L2. The blower fan is mounted in the control box and rated to supply sufficient air for combustion. Air pressure generated by the blower will cause the normally open burner pressure switch No. 1 to close. Another circuit is completed from L1 to the module ignition control and back to L2. There is a five second delay, then the glo-bar is powered. After the glo-bar has been powered for 45 seconds, the control module causes the gas valve to open and initiates the ignition trial. Power to the glo-bar is shut off during the last two or three seconds of the ignition trial. Running Circuit After ignition, the flame rod monitors the flame. As long as a flame is present, the valve is held open. If the flame is lost, the control acts to close the valve within one second, and a new trial sequence identical to that at start-up is initiated. If proof of flame is not established within 8.5 seconds, the unit will lock out. If lockout occurs, the control can be reset by briefly interrupting the power source. Roof Single Approved 3 rooftop raincap (RTVP-3). Roof Dual (Sharing common t-stat) Approved 4 rooftop raincap (RTVP-4). Important: Do not use sidewall caps for roof venting and do not use roof caps for sidewall venting. 4

5 Internal iring Diagrams LADDER DIAGRAM - MARK17DU-117 ITH THERMO L1 120VAC L2 BLOER INDICATOR LIGHTS THERMO SITCH GAS VALVE PRESSURE SITCHES O R IGNITOR BR PROBE SIC1 LINE1 TH NEUT VALVE NEUT GND G IGNITION MODULE IF ANY OF THE ORIGINAL IRE AS SUPPLIED ITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED ITH IRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. BLOCK DIAGRAM - MARK17DU-117 ITH THERMO TERMINAL BLOCK PRESSURE SITCHES BURNER L1 INDICATOR LIGHTS O THERMO SITCH IGNITOR BR FLAME ROD 120VAC L2 BLOER M 1 C 2 P 3 M 1 C 2 P 3 R MARK 17DU-117 IGNITION MODULE PROBE SIC1 LINE1 TH NEUT VALVE NEUT GND G GAS VALVE 5

6 LS Series Field iring Diagrams G R Common required for thermostats that require constant power. HEATER L2 L1 115V HITE TO HEATER BRANCH #1 VIOLET 24V 24V BY OTHERS HITE 115V TO HEATER BRANCH #2 HEATER HEATER BLACK TE: This Transformer Relay will handle up to 3 tube heaters per branch (6 tube heaters total) or up to 8 DR heaters per branch (16 DR heaters total) POLE #2 POLE #1 G Y RED/YELLO RED COIL R C B L2 L1 115V TE: Brown and Yellow wires on the R8285 transformer relay are normally not used. R 8285 Transformer Relay - Used in conjunction with any low voltage T-stat (i.e. XL411, T8600) when wiring tube heaters or line voltage DR heaters 24V T-Stat & Connection - Relay Tranformer Required FIELD IRING INSTRUCTIONS T-stat HEATER TE: Up to 4 line voltage tube heaters can be wired to most T-stats. Heaters on same vent must share the same t-stat. GRD NC COM HEATER HEATER L1 L2 120V Connection(s) FIELD IRING FOR MULTIPLE LINE VOLTAGE HEATERS 6

7 Alternative iring Diagrams MARK17DU-117 ITH THERMO TERMINAL BLOCK PRESSURE SITCHES BURNER T-STAT TERMINAL 24V L1 INDICATOR LIGHTS O THERMO SITCH IGNITOR BR FLAME ROD 120VAC L2 BLOER M 1 C 2 P 3 M 1 C 2 P 3 R MARK 17DU-117 IGNITION MODULE PROBE SIC1 LINE1 TH NEUT VALVE NEUT GND G GAS VALVE BLOCK DIAGRAM FOR INTERNAL RELAY OPTION THE INTERNAL RELAY ALLOS FOR LO VOLTAGE T-STAT OPERATION OF LINE VOLTAGE HEATERS COMMON REQUIRED FOR THEMOSTATS THAT REQUIRE CONSTANT POER. COMMON C N 24v ITH INTERNAL RELAY OPTION R 24v DIGITAL T-STAT EXTERNAL TRANSFORMER 24V N 24v ITH INTERNAL RELAY OPTION 120 V EXTERNAL TRANSFORMER IS NEEDED HEN USING THE INTERNAL RELAY OPTION. A 40VA TRANSFORMER IS SUFFICIENT TO OPERATE 10 APPLIANCES L2 L1 N 24v ITH INTERNAL RELAY OPTION FIELD IRING FOR INTERNAL RELAY OPTION 7

8 LS Series Troubleshooting Flow Chart Turn up thermostat Does the fan turn on? Does the switch light energize? Does the ignitor warm up and glow red? Does valve light come on? Is the light burnt out? If so, replace. Is the power at the heater 120V? Find the source of the electrical problem. Is the ignitor physically damaged? Is the inlet or the outlet of the unit obstructed (i.e. ice, birds nest, dirt)? Remove obstruction. Replace ignitor. Does burner ignite at all? Is the blower obstructed? Remove obstruction & lubricate fan. Check voltage at ignitor during ignition sequence (usually seconds after power to the heater). Is it 120V? Replace circuit board. Check for loose wiring or resistance in hose connection to pressure switch. Are they ok? Is there 120V coming to the fan? Correct wiring. The circuit board and/or wiring harness may be faulty and need to be replaced. Repair wiring. Is resistance through the ignitor S. Replace ignitor. Replace faulty light. The fan is faulty and must be replaced. Replace burned out light. Replace thermal fuse. The heater is equipped with 2 safety pressure switches. The burner switch in the blower compartment is a normally open switch and the exhaust switch in the gas valve compartment is a normally closed switch. Temporarily place jumpers across the terminals of each switch, one at a time. (Be sure to reinstall the cover.) Does the light energize? Temporarily place jumpers across the thermal fuse (be sure to reinstall the cover). Does the light energize? Replace the appropriate switch after verifying the following: * Baffle(s) is in the tube(s) farthest from the burner. * Heater, fan blower, squirrel cage, intake and exhaust are clean and free from dirt and obstructions. * The 4 air intake pipe does not exceed 20 feet and/or 2 elbows. * There is not a negative pressure experienced at the area of air intake (i.e. attic space, high-winds, very tight building). Does valve open? Check to make sure pressure is within min. & max. inputs as indicated on AGA burner rating label. Are both ok? Correct problem. Replace valve. 8

9 After ignitor is warmed up, does gas valve open? Test for 120V at valve during valve opening period (usually seconds after power to the heater). Is there 120V to valve? Check to make sure gas pressure is within minimum and maximum inputs, as indicated on AGA burner rating label. Is gas pressure ok? Possibly, the circuit board and/or wiring harness is faulty. These should be replaced. Correct problem. Replace gas valve. * ARNING: By-passing any pressure switch is for testing purposes only. Do not leave switch by-passed during normal operation or heater s built-in safety mechanisms will be compromised. Does the burner ignite? Is the gas cock in an ON position? Check to make sure gas pressure is within minimum and maximum inputs, as indicated on AGA burner rating label. Is gas pressure ok? Correct problem. Make sure gas lines were purged of air. Does the burner stay on? Does heater stay on until call for heat ends? The following can cause the heater to shut down: * Improper grounding. * High winds. * Taking combustion air from the attic. * Dirty environment. * Baffle not located properly. * Fluctuating gas pressure. Troubleshooting ends. Does the burner stay on for approx. 8 seconds and then shut off? Does the burner come on and then turn off immediately (1 or 2 seconds). Is the heater properly grounded? Is the heater s polarity correct? Check to make sure that the pressure is within minimum and maximum inputs as indicated on the AGA burner rating label. Is gas pressure ok? Correct problem. Correct problem. Exhaust pressure switch may be faulty or there is a restriction in the exhaust. Certain models have a separate glo-bar ignitor and flame rod sensor located next to the glo-bar. Other models have a glo-bar ignitor only, which acts as both an ignitor and flame sensor. Does model in question have glo-bar ignitor only? Consult factory for proper parts. ith voltmeter, check DC voltage at flame rod. Is it greater than 30 Volts DC? Sensing rod is faulty or flame is weak. Check to make sure heater is operating at proper gas pressure as indicated on AGA burner rating label and then replace sensing rod if needed. Check to make sure flame sensor wire is ok and then replace circuit board. 9

10 D 264E 1064B 264F A B A 31B 68A 55A B P F 1060D A LS Series - 3 Tube Heater Installation, Operation, Maintenance and Parts Manual LS Series Parts Breakdown Emitter Tube Combustion Tube C 10

11 Basic Parts List LS SERIES PARTS LISTING TP# ITEM TP# ITEM TP-1 CONTROL BOX COVER TP-264D N.O. BURNER PRESS. SITCH (30MBTU/H) TP-5 FLANGE GASKET TP-264E N.O. BURNER PRESS. SITCH (25MBTU/H) TP-9 CONDUIT COUPLING TP-264F N.O. BURNER PRESS. SITCH (40 MBTU/H) TP-10 CONDUIT 4" X 1/2" TP-301 DIVIDER PANEL / P.S. MOUNTING TABS TP-11 GLO-BAR IGNITOR BOX TP V INDICATOR LIGHT TP-12 GLO-BAR IGNITOR BOX COVER TP-329 1/4" NEUTRAL TERMINAL BLOCK TP-17 SIGHT GLASS KIT TP-330 DIVIDER GROMMET TP-20C 120" ALUMINUM REFLECTOR TP-331 GREEN SELF TAP GROUND SCRE TP-31B CONTROL BOX BRACKET TP-333 3' BLACK 120V PLUG TP-33B 1/2" GAS COCK TP-334 YELLO 24V CONTROL IRE TP-44 AIR ORIFICE /SCREEN - CONSULT FACTORY TP-351A MARK 17DU-117 POTTED CIRCUIT BOARD TP-50 GLO-BAR IGNITOR TP-352A LONG IRING HARNESS FOR 17DU-117 TP-55A FAN BLOER (40, 50, 60 MBTU/H) TP-1002 LEFT END PANEL / LIGHT HOLES TP-68A STRAIN RELIEF BUSHING TP-1003 RIGHT END PANELS - HOLES TP-70 CONTROL BOX COVER GASKET (PER FOOT**) TP-1004 CONTROL BOX TP-76 RUBBER GROMMET TP-1015 FAN BLOER (25, 30 MBTU/H) TP-83 STAINLESS STEEL FLEX CONNECTOR TP-1033 THERMAL FUSE TP-105 REFLECTOR END CAP TP-1060D EXHAUST PRESS. SITCH (25,30 MBTU/H) TP-106 REFLECTOR CLIP TP-1060F EXHAUST PRESS. SITCH (40,50 MBTU/H) TP-112 5' REFLECTOR TP-1064B N.O. BURNER PRESS. SITCH (50 MBTU/H) TP-122 GASKET FOR AIR ORIFICE & AIR COLLAR TP-1062 EXHAUST PRESSURE TUBE (VINYL) TP-204 GAS ORIFICE - CONSULT FACTORY TP /4" ATMOSPHERIC & PRESSURE TUBES (VINYL) TP-205 GLO-BAR HOLDER TP-1070 BURNER (25 TO 50 MBTU/H) TP-208 "Z" MOUNTING BRACKET TP-1077 TUBE CLAMP TP E36A-246 GAS VALVE - NAT GAS ASSY TP-1078 REFLECTOR CENTER SUPPORT TP-209P 36E36A-240 GAS VALVE - LP GAS ASSY TP-1079 IRE HANGER / SPRING CLIP TP-212 1/2" X 3" PIPE NIPPLE TP '' BURNER TUBE ITH FLANGE TP-217 PRESSURE BARB FITTING TP FT. TITANIUM COMBUSTION TUBE TP-221 GLO-BAR HOLDER GASKET TP FT. STAINLESS RADIANT TUBE TP-222 FLAME ROD TP " S.S. INTERLOCKING 33" PRESSURE BAFFLE ITH TABS TP-222A FLAME ROD IRE TP " S.S. INTERLOCKING 33" HEAT BAFFLE SECTION TP-223 GAS MANIFOLD ** 6 TOTAL NEEDED TO COVER OUTER EDGES OF A (TP-70). 11

12 KIT CONTENTS AND PRODUCT FEATURES Kit contents for the LS Series are shown below. Reference the proper column for your particular models length. FILLED BY: LS SERIES KIT CONTENTS TP# DESCRIPTION 10 FOOT 15 FOOT 20 FOOT 30 FOOT TP " TUBE CLAMPS TP " HANGERS TP " REFL. CNTR. SPRT TP-105 REFL. ENDCAPS TP-106 REFL. ENDCAP CLIPS TP-33B 1/2" GAS COCK TP-83 24" SS FLEX LINE IOM INSTALL / OP MANUAL Reflector Center Support TP SS Flex Connect TP-83 3 Hanger TP Butt Clamp TP /2 Gas Cock TP-33B Reflector End Caps TP- 105 Bag of Reflector endcap clips TP-106 General IOM (LIOGT) AND Series Insert (LIOLS) Product Features APPROVALS IAS, CGA, AGA, CSA. Certain models are residentially certified to AGA No Outdoor Approval with OD-KIT. BURNER SIGHT GLASS For burner inspection. COMBUSTION AIR INLET & VENT 4 air inlet duct. 3 vent duct. CONTROLS 100% safety shut off. Moisture and corrosion resistant ignition module. Dual differential pressure switches. Silicon carbide hot surface igniter. Flame rod sensing. Pre-purge controls. Indicator lights. ENAMELED CONTROL BOX Outside air collar (4 ) attached. Totally enclosed components. EMMITER & COMBUSTION TUBES 16ga. 3 O.D. titanium coated combustion chamber. 16ga. 3 O.D. aluminized steel radiant tubes. OPTIONAL FEATURES 24VAO - Used when operating heater with 24V thermostat. Includes internal relay, power cord and indicator lights. External transformer required. GAS CONNECTION 1/2 gas cock included. 24 x 1/2 flex connector included. RADIANT SURFACE AREA (SQ. FT.) 10 models models models ARRANTY* 1 year - Burner box components. 3 years-combustion and radiant tubes. 5 years-stainless steel burner. * See cover for warranty registration information. OTHER One reflector center support per reflector. Stainless steel turbulator baffle included. Stainless steel upgrades (burner box and reflectors only) are available. Silicone sealed control box available. Made in U.S.A. Visit for additional information & parts. 12

Typical Mount Height. Combustion Chamber

Typical Mount Height. Combustion Chamber ! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Typical Mount Height. Combustion Chamber(s)

Typical Mount Height. Combustion Chamber(s) XTS Series - 4-4 Tube Tube Heater Heater Installation, Installation, Operation, Operation, Maintenance Maintenance and Parts and Manual Parts Manual! ARNIN: This heater must be installed and serviced by

More information

DX2 Series. Models V.6/03

DX2 Series. Models V.6/03 ! ARNIN: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

For complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual.

For complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual. Insert Manual For complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual. The Infrared Tube Heater is a positive pressure, single-stage radiant

More information

Insert Manual. DES Series WARNING. For Your Safety

Insert Manual. DES Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infra-Red Tube Heater is a positive pressure, single-stage radiant

More information

Insert Manual. SV Series WARNING. For Your Safety

Insert Manual. SV Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a negative pressure, single-stage radiant

More information

Insert Manual. DX3 Series WARNING. For Your Safety

Insert Manual. DX3 Series WARNING. For Your Safety DX3 Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The DX3 Series Infrared Tube Heater is a positive pressure, single-stage

More information

Insert Manual. DET3 Series WARNING. For Your Safety

Insert Manual. DET3 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infra-Red Tube Heater is a positive pressure, two-stage radiant

More information

Insert Manual. XTS3 Series WARNING. For Your Safety. For complete installation instructions, see the General Manual that accompanies this insert.

Insert Manual. XTS3 Series WARNING. For Your Safety. For complete installation instructions, see the General Manual that accompanies this insert. Insert Manual For complete installation instructions, see the General Manual that accompanies this insert. The Infrared Tube Heater is a positive pressure, single-stage radiant heater system. This insert

More information

Insert Manual. RHT Series WARNING. For Your Safety

Insert Manual. RHT Series WARNING. For Your Safety RHT Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The RHT Series Infrared Tube Heater is a positive pressure,

More information

Insert Manual. RVA2 Series WARNING. For Your Safety

Insert Manual. RVA2 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater

More information

Insert Manual. DES3 Series WARNING. For Your Safety

Insert Manual. DES3 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, single-stage radiant

More information

Insert Manual. DX3 Series WARNING. For Your Safety

Insert Manual. DX3 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The Infrared Tube Heater is a positive pressure, single-stage radiant heater

More information

TUBE HEATER TROUBLESHOOTING GUIDE

TUBE HEATER TROUBLESHOOTING GUIDE TUBE HEATER TROUBLESHOOTING GUIDE MODELS: DTH(S) Series Tube Heaterer THESE HEATERS MUST BE INSTALLED AND SERVICED BY TRAINED GAS INSTALLATION AND SERVICE PERSONNEL ONLY. READ AND UNDERSTAND ALL INSTRUCTIONS

More information

Insert Manual. DX3L Series WARNING. For Your Safety

Insert Manual. DX3L Series WARNING. For Your Safety DX3L Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The DX3L Series Infrared Tube Heater is a positive pressure, single-stage

More information

* For complete installation instructions, see General IOM this piece was inserted within. Also available at Min. Mtg.

* For complete installation instructions, see General IOM this piece was inserted within. Also available at  Min. Mtg. *! ANIN: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters. 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in

More information

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls TM SERIES Available with 40,000 to 200,000 BTU/Hr. inputs and tube lengths from 10 feet to 70 feet. Aircraft Hangars Auto Dealerships Farm Buildings Fire Stations Body Shops Car Washes Sports Facilities

More information

CLEARANCES TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape

More information

DX SERIES TUBE HEATER

DX SERIES TUBE HEATER DX SERIES TUBE HEATER INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open windows. 2. Do not touch electrical switches. 3.

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all

More information

TUBE HEATER TROUBLESHOOTING GUIDE

TUBE HEATER TROUBLESHOOTING GUIDE TUBE HEATE TOUESHOOTING GUIDE MODELS: HLV Series Tube Heaterer THESE HEATES MUST BE INSTALLED AND SEVICED B TAINED GAS INSTALLATION AND SEVICE PESONNEL ONL. EAD AND UNDESTAND ALL INSTUCTIONS THOOUGHL BEFOE

More information

Service Manual Model 3163

Service Manual Model 3163 Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................

More information

Power Direct Vent PDV(S&T) Models

Power Direct Vent PDV(S&T) Models COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) 100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) WARNING If the information in these instructions is not followed exactly, a

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........

More information

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!

DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY! DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open Windows. 2. Do not touch electrical switches. 3.

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

Insert Manual. HL3 Series WARNING. For Your Safety

Insert Manual. HL3 Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-51012-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest w ater heaters on

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

CSD-1 COMMERCIAL BOILER CONTROLS

CSD-1 COMMERCIAL BOILER CONTROLS SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock

More information

Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater INSTALLATION / OPERATION / MAINTENANCE Applies to: Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater Model VPT High/Low Burner/Control Box with 20-70 ft Tube/Reflector Length

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

LS Series Installation Manual

LS Series Installation Manual Installation Manual The Infrared Tube Heater is a positive pressure, single stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater)

Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) Form RH-IOM-11 210080 Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) MODEL IDENTIFICATION Record the information

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

SERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage

SERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage Installation, Operation and Service Instructions INFRARED HEATER SERIES EvenTube Model ETS Infrared Patio Heater Two-Stage WARNING: FOR OUTDOOR USE ONLY WARNING Improper installation, adjustment, alteration,

More information

Installation, Operation, Maintenance and Parts Manual

Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual 7DC27 thru 7DC32 Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

MICRO 60U24 CONTROL Micro-Processor Based Control

MICRO 60U24 CONTROL Micro-Processor Based Control HL-2 SERIES TUBE HEATER - VERSION 9/00 MICRO 60U24 CONTROL Micro-Processor Based Control INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual Installation, Operation, Maintenance, and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully

More information

Tube Heater General Manual

Tube Heater General Manual Detroit Radiant Products Co. Tube Heater General Manual To be used in conjunction with Series 2 insert manuals. WARNING Improper installation, adjustment, alteration, service, or maintenance can cause

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater)

Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) Form RH-IOM-15 11222016 Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) MODEL IDENTIFICATION Record the information

More information

tio-pal PH Series Gas-Fired High Intensity Infra-Red Patio Heater ! WARNING! WARNING! WARNING! WARNING! FOR YOUR SAFETY FOR YOUR SAFETY

tio-pal PH Series Gas-Fired High Intensity Infra-Red Patio Heater ! WARNING! WARNING! WARNING! WARNING! FOR YOUR SAFETY FOR YOUR SAFETY Patio-Pal PH Series Patio Heater Installation, Operation, Maintenance and Parts Manual! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper

More information

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail SECTION 7: OPTIONAL HEATER ACCESSORIES Step 7.2.4 Reflector Joint Installation Cut away contour with tin snips. Punch/drill six 3/32" (2 mm) holes. Step 7.2.5 Reflector Joint Detail Install reflector end

More information

Insert Manual. CL Series WARNING. For Your Safety

Insert Manual. CL Series WARNING. For Your Safety Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater

More information

Cumberland Heating Systems

Cumberland Heating Systems Cumberland Heating Systems Cumberland "Radiant" Brooder Clean Burning...Fuel Efficient Maintaining proper in-house temperature is critical in climate control. A consistent, stressfree environment promotes

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

PE MODEL WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

PE MODEL WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! PE MODEL ATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today!

More information

Effective october 14, 2014

Effective october 14, 2014 COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified

More information

Quad Tube Heaters WARNING WARNING. Installation, Operation, Maintenance and Parts Manual

Quad Tube Heaters WARNING WARNING. Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only Read carefully

More information

MASTERTEMP HEATER REPLACEMENT PARTS

MASTERTEMP HEATER REPLACEMENT PARTS 0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin Boilers Water Heaters CB CW 987-2067 52 21 18

More information

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS.  Page 1 PROJECT: ENGINEER: CONTRACTOR: SUBMITTAL DATA & U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: www.schwankgroup.com Page

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS

Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

LD Series Installation Manual

LD Series Installation Manual Installation Manual The Infrared Tube Heater is a positive pressure, two stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED

More information

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html 1 2 3 4 5 Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity.

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTS 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

Series RE Infrared Heater

Series RE Infrared Heater Series RE Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,

More information

EHL Series Installation, Operation, Maintenance and Parts Manual

EHL Series Installation, Operation, Maintenance and Parts Manual Installation, Operation, Maintenance and Parts Manual CE Certified 230V-50Hz. [G20(C5), G25(C6), G31(C7)] Infrared Tube Heater. The EHL Series Infrared Tube Heater is a positive pressure, two-stage radiant

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

Suburban RV FURNACES SERVICE MANUAL

Suburban RV FURNACES SERVICE MANUAL Suburban RV FURNACES SERVICE MANUAL DD-17DSI DD-17DSIW NT-12S/SE NT-16S/SE NT-20S/SE NT-24SP NT-30SP NT-34SP NT-40 P-30S/40 SF-20 SF-25 SF-30 SF-35 SF-42 SF-20F SF-25F SF-30F SF-35F SF-42F SH-35 SH-42

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-474 & 50A55-571 Integrated Furnace Controls INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

BGH Series Hot Surface Ignition Control

BGH Series Hot Surface Ignition Control Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor

More information

Installation & Operation Manual NCB-E Condensing Combi-Boilers

Installation & Operation Manual NCB-E Condensing Combi-Boilers Installation & Operation Manual NCB-E Condensing Combi-Boilers Model NCB-210E NCB-240E H NSF/ANSI 72 Keep this manual near this boiler for future reference whenever maintenance or service is required.

More information