saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet
|
|
- Annice Hunter
- 6 years ago
- Views:
Transcription
1 Notes: 1 Square = Foot/Feet saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. Revision C 2/14/2013 Titan Controls
2 Warnings & Cautions Saturn 5 Digital Environmental Controller with CO 2 Timer Instructions for Operation Troubleshooting Tips Saturn 5 2 Controller Specifications Installation Example Warranty Information Service and Repair Program Warnings & Cautions Read all instructions before operating controller. Do not put your controller in an area where it can get wet or sprayed. Mount your controller securely to the wall. When using bug bombs in area, cover controller completely to avoid corrosion. There are no serviceable parts in controller. Do not attempt to repair the unit. Breaking tamper proof seal will void your warranty. Do not put paper clips, tools, etc. into unit. Possible electrocution may occur. Plug controller into surge protector to avoid potential damage to the unit. Confirm that your power source is 120 Volts/15 Amps prior to plugging controller into outlet. Check that all equipment that will be activated by this controller is the proper voltage(s). Verify that the equipment you are controlling does not exceed a total of 14.5 Amps. This controller is designed for inside use only. Avoid placing the controller near heat generating sources such as a CO 2 Generator. Use caution if operating controller in extremely humid environments (90% and above). Do not use controller for purposes other than the unit was designed to function. Use controller within defined environmental specifications. Ask your Dealer for tips and techniques regarding the use of this controller. Be conscientious when disposing of any products. Enjoy your Titan Controls environmental controller for years to come. CAUTION: DO NOT install your controller near electronic/digital ballasts, ozone generators and other devices that emit large amounts of electromagnetic interference (EMI) & radio frequency interference (RFI), it will disable the controller. Maintain a minimum distance of 8 feet between the controller & sensor, and all high EMI/RFI devices. WARRANTY SERVICE: Please read warranty information first If after reviewing the troubleshooting tips the unit will still not work, you should return it to the Dealer where you purchased it. They may be able to further evaluate the unit and test its various components and quite possibly will be able to identify and/or fix any problems. If the Dealer is unable to fix the unit, they will return it to us for factory repair. If there are no Dealers in your area, you may contact us directly for technical support. If we cannot help you resolve the problem over the phone, we will issue you a Return Merchandise Authorization (RMA) number authorizing you to return the unit to us for factory reconditioning (if the controller is currently under warranty). Contact the number below for a RMA number and shipping address. Please complete the form below and include it with your unit, and write the RMA number clearly on the outside of the box. Please package the unit in its original packaging. If it is damaged in shipment we cannot be held responsible. Insuring the parcel is recommended. Once we receive the unit back, we will repair it within 48 hours (business) and return it to you freight prepaid via UPS ground shipment. Include the following if returning directly to Titan Controls Proof of purchase This completed form RMA # on the outside of the box Return Merchandise Authorization Number (Required): Dealer/Customer Name: Dealer/Customer Contact Name: Shipping Address: Phone #: address: What is the nature of the problem? Please provide as much information as possible. Shipping address will be given when the RMA # is issued. For technical assistance call TITAN or
3 Warranty Information Titan Controls warrants the original purchase of this product against defects in material and workmanship under normal use for three (3) years from the date of purchase. During the warranty period, Titan Controls will, at our option, and without charge, repair or replace this product if the controller or any of its components fail or malfunction. All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) number prior to any service of the product. This warranty is in lieu of all other warranties, expressed or implied, including the warranties of merchantability and fitness for use, and of all other obligations or liabilities on the part of the seller. This warranty shall not apply to this product or any part thereof which had been damaged by accident, abuse, misuse, modification, negligence, alteration or misapplication. Controllers with serial numbers or date tags that have been removed, altered or obliterated; broken seals that show evidence of tampering; or nonconforming parts, are excluded from coverage. Titan Controls makes no warranty whatsoever in respect to accessories or parts not supplied by Titan Controls. Monetary refunds of the warranty will not be given. The Buyer assumes all responsibility regarding the proper use & installation of this controller. All warranty service is provided through the Titan Controls factory. This warranty shall apply only to the United States, including Alaska, Hawaii and territories of the United States and Canada Defective controllers are required to be returned with the proof of purchase/ receipt for warranty coverage. For additional warranty information, contact the Titan Controls Technical Service Representative at or your local Dealer. NOTE: Titan Controls is a Manufacturer of environmental, timing, lighting, ventilation and CO 2 controls. All sales offerings to the public are done through a nationwide group of Dealers. No sales offerings will be made directly to the general public. Service & Repair Program For all service and repairs, please contact by our Technical Service Representative for troubleshooting your gear and attaining a Return Merchandise Authorization (RMA) number, if applicable. All factory service & repairs will be completed within 48 hours of receipt of controller at the factory. Titan Controls will, at its discretion, repair or replace the controller. Factory calibration services are available for all Titan Controls. Returning Units: Please contact your retail store for information regarding returns. 10 Saturn 5 Digital Environmental Controller with CO 2 Timer The Saturn 5 is a digitally based environmental controller featuring a short cycle timer for CO 2 enrichment. It utilizes a 15 foot remote sensor to operate your temperature, humidity, CO 2 system and nighttime gear. This controller gives you the ability to set day and night temperature levels. The Saturn 5 has an LCD display and color coded push buttons for easy programming. This device also offers min/max data logging capabilities for temperature and humidity. Operation Instructions 1. Securely mount your Saturn 5 in your grow area and away from any moisture, spray, pesticides or other materials that could harm the unit. 2. Verify that when the Saturn 5 s is mounted in your grow room the PHOTOCELL is exposed to your grow lights and not shaded or covered. 3. Ensure that all of the devices being connected to the controller are 120 Volt only and will not exceed the maximum amperage rating for the Saturn Connect your gear (exhaust fan, CO 2 controller, night circulation fan, dehumidifier, etc.) to the Saturn The sensor has a quick connect cord set to easily connect or move the sensor. Secure the quick connect cord to the Saturn 5 by plugging it in and securing the QD screw to the unit. 6. Place the sensor in an area with good air movement, preferably plant height. Avoid placing the sensor in direct sunlight or under direct HID lighting. NOTE: Do not place sensor anywhere it might get wet. SENSOR IS NOT WATER PROOF. 7. Plug the power coble into a standard 120 Volt wall outlet. 8. Using the buttons, select the TEMP, HUMID & CO 2 parameters to program the Saturn The Saturn 5 should now activate and deactivate your equipment based on the preferred settings you selected. COOLING OUTPUT: This outlet is intended to active an exhaust fan to ventilate the garden due to high temperature conditions. Do not exceed 5 Amps when using this output. CO 2 OUTPUT: This outlet is for a CO 2 device and powers ON during the daytime period only. It will deactivate when the Cooling Output is activated. By achieving this, you are not ventilating the CO 2 as you re enriching your grow area and wasting your CO 2. NIGHTTIME OUTPUT: The outlet can be used for a variety of devices that only require power at night. This outlet activates only during the nighttime period. 3
4 HUMIDITY OUTPUT: This output is for use with a humidifier or dehumidifier. Do not exceed 5 Amps when using this output. Installation Example FAHRENHEIT - CELSIUS: To change the temperature from F to C, press and hold the UP & DOWN buttons for 2 to 3 seconds at the same time. PHOTOCELL SENSITIVITY: By pressing and holding the ENTER/RESET and UP buttons for 3 seconds, you can change the sensitivity of the photocell. The current photocell setting will appear on the LCD. Press the DOWN button to decrease the sensitivity of the photocell (will require more light to activate the photocell. Press the UP button to increase the sensitivity of the photocell (will require less light to activate the photocell). Temperature & Humidity Sensor There are 15 buttons located on the front face plate of the unit that control all functions. Pressing each button will display a function and/or current setting(s) in the green LCD window. Some buttons are programmed to perform more than one function. The small green LED lights or status indicators located on the front panel will light up to show the selected function when certain buttons are pushed. UP Press this button to increase setting. DOWN Press this button to decrease setting. ENTER/RESET Press button, hold for 3 seconds to enter new setting and to reset the Min/Max range. TEMPERATURE BUTTONS DAYTIME SETTING Press button to set day cooling set point. Press ENTER/ RESET to accept setting. NIGHTTIME SETTING Press button to set night cooling set point. Press EN- TER/RESET to accept setting. TEMP DEADBAND Press button to set the cooling deadband range. Press ENTER/RESET to accept setting. This button is used to determine the number of degrees above/below for when the cooling outputs will activate. Example: If your cooling function is set at 85 F and the deadband is 3 F, the output will activate your exhaust fan when the temperature is above 85 F and deactivate your exhaust fan when the temperature is below 82 F. CO2 Regulator HUMIDITY BUTTONS HUMIDITY SETTING Press button to set Day and Night Humidity settings. HUMIDITY MODE - Press button to select humidification (rh Incr) function or dehumidification (rh decr) function. 4 9
5 Troubleshooting Tips 1. The Saturn 5 has no power? Verify power source is providing 120 Volts A/C. Reset the circuit breaker on the Saturn 5 by turning OFF the unit, than turn ON. 2. What if the CO 2 timer is not keeping the right time? The CR Volt Lithium battery, located on the internal circuit board that is connected to the inside of the front faceplate, may need to be replaced. The normal lifespan of the batteries is approximately 5 years. 3. Why are the Error LED s on the front lit? The sensor or connected device are malfunctioning. See ERROR LED s section for more information. 4. Why is the display showing, Err SEn? The remote sensor is not connected or not communicating with the Saturn 5. Verify that the cable is not compromised and that the remote sensor has power. 5. Does the humidity and temperature sensor need to be calibrated? No. The humidity and temperature sensor is digital and there is no need for calibration. 6. Why is my temperature is reading quite high? Verify that the sensor is not in a location with direct exposure to intense light and that there is air circulating freely around it. Controller Specifications Size = 9 H x 7 W x 3 ¾ D Input voltage = 120 Volts A/C Output voltage =120 Volts A/C Maximum amperage = 14.5 Amps Remote probe cable length = 15 feet Temperature control range = 41 F to 113 F Temperature accuracy = +/- 2% F Temperature deadband (hysteresis) = Adjustable Humidity control range = 5% to 95% rh (non-condensing) Humidity accuracy = +/- 3% rh Humidity deadband (hysteresis) = Adjustable CO 2 ON time = 1 second to 12 hours CO 2 OFF time = 1 second to 96 hours HUMID DEADBAND Press button to set the humidity deadband setting. This humidity dead band determines when the humidity output will function based on how many percentage points above or below the set point that the humidity will be. Example: If the Saturn 5 is set to dehumidify and your deadband is 5%rH, the output will activate your equipment at 50% and deactivate your equipment at 45%. CO 2 BUTTONS CO 2 MODE Press button to change the CO 2 Mode from daylock to dayfree. Select daylock to disable the CO 2 OUTPUT when the COOLING OUTPUT is activated. Choose this mode when you are using exhaust fans to cool your garden. Or you may select dayfree to allow the CO 2 OUTPUT and COOLING OUTPUT to be activated at the same time. Use the dayfree mode in sealed room situations or when using an air conditioner to cool your grow room. CO 2 ON TIME Press this button to determine the amount of time that the CO 2 OUTPUT will be activated to enrich your garden. CO 2 OFF TIME Press this button to determine the amount of time that the CO 2 OUTPUT will be de-activated and NOT providing CO 2 to your garden. NOTE: The CO 2 ON TIME and CO 2 OFF TIME can be used as a daytime recycle timer (dayfree mode) to run a pump,etc. if you choose not to use CO 2 in your garden. SPECIAL BUTTONS TEMP & HUMID LOCK The temperature and humidity may be set to operate in locked (connect) or split (SPLit) modes. This button allows you to run your temperature and humidity gear either at the same time or independently. MIN/MAX TEMP Press this button to recall the stored high and low recorded temperature levels. Press and hold the ENTER/RESET button while this setting is displayed to reset them. MIN/MAX HUMID Press this button to recall the stored high and low recorded humidity levels. Press and hold the ENTER/RESET button while this setting is displayed to reset them. ADJUSTING THE SETTINGS: Your Saturn 5 has been pre-set at the factory with the following settings: TEMP DAY SETTING = 80 F TEMP NIGHT SETTING = 70 F TEMP DEADBAND = 3 F DAY/NIGHT HUMID SETTING = 50% rh HUMID MODE = DECREASE (rh decr) HUMID DEADBAND = 5% rh 8 5
6 CO 2 MODE = Dayfree (dayfree) CO 2 ON TIME = 1 minute CO 2 OFF TIME = 30 minutes TEMP & HUMID LOCK = Split (SPLit) If you ever want to return to the factory settings do the following: Press and hold the ENTER/RESET & DOWN buttons at the same time until the LED reads (f.set). Press the ENTER/RESET button again to restore the Saturn 5 to the factory settings. Once the Saturn 5 reset is complete, the LED screen will read (done). To adjust your Saturn 5 to your own customized settings, do the following: TEMP DAY setting = Press TEMP DAY button and the LCD will display COOL_F. To adjust the daytime temperature use the UP and DOWN buttons. Press ENTER/RESET to lock in the new setting. TEMP NIGHT setting = Press the TEMP NIGHT button and the LCD will display COOL_F. To adjust the nighttime temperature use the UP and DOWN buttons. Press ENTER/RESET to lock in the new setting. DAY/NIGHT HUMID setting = Press the DAY/NIGHT HUMID button one time and the LCD will display day_rh. To adjust the daytime humidity use the UP and DOWN buttons. Press ENTER/RESET to lock in the new setting. DAY/NIGHT HUMID setting = Press the DAY/NIGHT HUMID button two times and the LCD will display nit_rh. To adjust the nighttime humidity use the UP and DOWN buttons. Press ENTER/RESET to lock in the new setting. HUMID DEADBAND setting = Press the HUMID DEADBAND button to display the current humidity deadband setting. To adjust the setting use the UP and DOWN buttons then press ENTER/RESET to lock in the new setting. CO 2 MODE setting = Press the CO 2 MODE button and the LCD will display the current mode, either daylock or dayfree. To adjust the CO 2 MODE use the UP and DOWN buttons. Press ENTER/RESET to lock in the new setting. CO 2 ON TIME = Press the CO 2 ON TIME button to display the current setting. The first two digits (hours) will blink. To adjust the hours, use the UP and DOWN buttons to set how many hours the CO 2 OUTPUT will be activated. Then press the ENTER/RESET button to lock in the new setting. Now the middle two digits (minutes) will be blinking. To adjust the minutes, use the UP and DOWN buttons to set how many minutes the CO 2 OUTPUT will be activated. Press the ENTER/RESET button to lock in the new setting. Finally, the last two digits (seconds) will blink. To adjust the seconds, use the UP and DOWN buttons to set how many seconds the CO 2 OUTPUT will be activated. Press the ENTER/RESET button to lock in the new setting. CO 2 OFF TIME = Press the CO 2 OFF TIME button to display the current setting. The first two digits (hours) will blink. To adjust the hours, use the UP and DOWN buttons to set how many hours the CO 2 OUTPUT will be deactivated. Then press the ENTER/RESET button to lock in the new setting. Now the middle two digits (minutes) will be blinking. To adjust the minutes, use the UP and DOWN buttons to set how many minutes the CO 2 OUTPUT will be deactivated. Press the ENTER/RESET button to lock in the new setting. Finally, the last two digits (seconds) will blink. To adjust the seconds, use the UP and DOWN buttons to set how many seconds the CO 2 OUTPUT will be deactivated. Press the ENTER/RESET button to lock in the new setting. TEMP & HUMIDITY LOCK = Press TEMP & HUMIDITY LOCK to display the current setting. Use the UP and DOWN buttons to select the new setting. Press ENTER/RESET to confirm the new setting. 1. To operate in the locked mode, select connect and use an exhaust fan for cooling or dehumidifying your garden. The exhaust fan will activate when heat or humidity exceeds your pre-set levels and deactivate when both the temperature and humidity are under your pre-set levels. 2. To operate in the split mode, select SPLit and use an exhaust fan for cooling and a dehumidifier to reduce your humidity level. The exhaust fan will activate when the temperature exceeds your pre-set level and deactivate when the temperature is under your pre-set level. The dehumidifier will activate when the humidity exceeds your pre-set level and deactivate when the humidity is under your pre-set level. NOTE: Select split mode (SPLit) if using a exhaust fan or AC unit to cool and a humidifier to increase humidity in your grow area. The cooling device will turn ON when the temperature rises above the set point and the humidifier will turn ON when the humidity drops below the set point. ERROR LED s The Saturn 5 regularly monitors the temperature and humidity levels and will alert the grower if there is an issue. If the Saturn 5 does not detect a slight change in the temperature or humidity in your grow area in one hour, it will deactivate the OUTPUT and the associated green LED will be blinking to acknowledge the possible problem. This safety feature is critical to eliminate runaway conditions that could result in crop damage or other serious issues. If you have a blinking LED, stop and check that your equipment is running properly and verify that the remote sensor has not been compromised. ERROR LED RESET To reset an ERROR LED, simply press the ENTER/RE- SET button. 6 7
saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual Notes: 1 Square = Foot/Feet
Notes: 1 Square = Foot/Feet saturn 5 Digital Environmental Controller with CO 2 Timer Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. www.titancontrols.net Revision E 6/14/2013
More informationHades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet
Notes: 1 Square = Foot/Feet Hades 2 Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. www.titancontrols.net Revision
More informationEOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #
EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part # 702603 www.titancontrols.net 120V High Amperage Digital Humidity Controller Warnings and Cautions Factory Settings Eos 120V
More informationwww.titancontrols.net Warnings & Cautions Zephyr 3 - Heating/Cooling Controller Instructions for Operation Troubleshooting Tips Controller Specifications Installation Example Warranty Information Service
More informationNotes: 1 Square = 1 Foot
Notes: 1 Square = 1 Foot Kronus 4TM Temperature, Humidity, CO2, Day and Night Controller Instruction Manual VANCOUVER, WASHINGTON U.S.A. VANCOUVER, WASHINGTON U.S.A. Warnings & Cautions Kronus 4 Kronus
More informationDDAC-1 deluxe digital atmosphere controller
Page 1 DDAC-1 DDAC-1 deluxe digital atmosphere controller Specs 1 Basic Description 1 Installation 2 Button Functions 3-4 Error LEDs 5 Factory Settings 6 Overview 7 How to customize settings 8-12 Photocell
More informationTsunami 6 Site Ebb & Flow Gro System Instruction Manual
Notes: 1 Square = Foot / Feet Hydrogardening Bucket Systems Tsunami 6 Site Ebb & Flow Gro System Instruction Manual Featuring Titan Controls Oceanus 3 Controller VANCOUVER, WASHINGTON U.S.A. www.flo-n-gro.net
More informationInstruction Manual EVC-2
Troubleshooting & Specs EVC-2 Amps / Volts requirements 15 amps @ 120 volts Min / Max operating temperature 32 to 120 F Temperature Accuracy +/- 1 F Temperature Mode Heat or Cool Min / Max Humidity 0-99%
More informationInstruction Manual CHHC-1
Troubleshooting & Specs CHHC-1 Amps / Volts requirements 15 amps @ 120 volts Remote sensor cable length 16ft (can be up to 100 ) Min / Max operating temperature 32 to 120 F Min / Max operating Humidity
More informationfailure is not an option
failure is not an option ABOUT US Based in the Pacific Northwest, Titan Controls is a manufacturer of environmental controllers, precision timers, lighting controllers, CO 2 equipment, and growing systems.
More informationUSER MANUAL. REVOLVE F20 (Repeat Cycle and Light Combo Timer ) AutopilotControllers.com APE2200
USER MANUAL REVOLVE F20 (Repeat Cycle and Light Combo Timer ) APE2200 AutopilotControllers.com AutopilotControllers.com 2 TABLE OF CONTENTS OVERVIEW 4 PARTS LIST - (WHAT S IN THE BOX) 5 LED DISPLAY & CONTROL
More information36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included
F3610G FMI PRODUCTS, LLC 36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included FMI Products, LLC TABLE OF CONTENTS Safety Information... 3 Operating Instructions...
More informationVX SERIES Wireless Thermostat with Occupancy Sensor
VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat
More informationMaxLite LED High Bay Fixtures
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationMODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN
CONVECTION OVEN 1/4 SIZE PAN MODEL 620 Convection is the ideal way to cook convenience foods and this compact oven can bake it all. Heated, circulating air throughout the oven penetrates food quickly.
More informationSunleaves Air Conditioner
Sunleaves Air Conditioner Thank you for purchasing this quality Sunleaves Air Conditioner! Please read through this manual completely, and keep it in case you need to reference the information in the future.
More informationELECTRIC FIREPLACE OWNER S MANUAL
ELECTRIC FIREPLACE OWNER S MANUAL MODELS EL1346C 4001358 WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury
More informationOwner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM
Owner s Manual Model S1-THEH21P5S HVAC SERVICE PARTS TM Heat Pump 5+2 Programmable Digital T h e rm ostats t a t BACKLIT DISPLAY Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool Control up
More information5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08
Digital Thermostat residential THERMOSTAT 5+2 DAY PROGRAMMABLE up to 1-heat & 1-cool PUMP Stages: 1-Heat, 1-Cool Battery or System Powered Back-Lit Digital Display Fahrenheit or Celsius Service Filter
More informationMODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET
FOOD WARMING/ MERCHANDISING CABINET MODEL 925W This warmer/merchandiser provides heated circulating air to keep foods fresh and evenly warmed. It is constructed of stainless steel and tempered glass for
More informationAPCETHD. Specs 1. Basic Description 1. Installation 2. Photocell sensitivity 2. Button Functions 3-4. Error LEDs 5. Factory Settings 6.
Specs 1 Basic Description 1 Installation 2 Photocell sensitivity 2 Button Functions 3-4 Error LEDs 5 Factory Settings 6 Overview 7 How to customize settings 8-10 Q & A 11 Warning 12 Warranty 15 Page 1
More informationOWNER S MANUAL 1-2 PERSON SAUNA
Rev. 9/5, Ver. 5 OWNER S MANUAL -2 PERSON SAUNA WITH CARBON HEATERS SA2402 TABLE OF CONTENTS ASSEMBLY TIPS & WARNINGS PARTS IDENTIFIER ASSEMBLY INSTRUCTIONS OPERATION INSTRUCTIONS ENJOYING YOUR SAUNA HEALTH
More informationThermometer with Probe model 00891A
Instruction Manual Thermometer with Probe model 00891A CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Temperature Units... 4 Placement
More informationOwner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool
Owner s Manual Model S1-THEH21NS HVAC SERVICE PARTS TM Heat Pump Non- Programmable Digital T h e rm ostats t a t Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool Control up to 2-Heat & 1-Cool
More informationMold Alert... Operation Manual P0270
Mold Alert... Operation Manual P0270 introduction Congratulations on your purchase of the P0270 Mold Alert! Mold is as old as the Earth and it s everywhere. Under the right set of conditions, it can actually
More information5) Do not start or stop the unit by inserting or pulling out the power plug.
3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance
More informationHumidity Monitor model 01080
Instruction Manual Humidity Monitor model 01080 Features & Benefits 19 18 1 2 3 4 12 11 10 17 16 5 9 RECORDS ºC/ºF 15 14 FRONT 6 7 8 1. Humidity Level Indicator Indicates a high, low or ideal humidity
More informationCarrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad
Carrier Heating & Cooling TSTATCCNB00 NON-PROGRAMMABLE DIGITAL THERMOSTAT USER INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW THERMOSTAT NON-PROGRAMMABLE DIGITAL THERMOSTAT AUTO 74 Dual
More informationPRACTICAL USER S GUIDE FOR THE contempra ef STOVE
PRACTICAL USER S GUIDE FOR THE contempra ef STOVE Quality checked by: Valued Customer, We are pleased that you have chosen to purchase an electric stove manufactured by Dimplex North America Limited. 7205040100REV05
More informationPORTABLE AIR CONDITIONER OWNER S MANUAL
PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 JHS-A018-14KRH SKU#: 130009 WARNING: Read and follow all warnings
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model DF2000L DF2000CR 6908890459 6908890559 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model DF2500L 6908920359 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings
More informationOWNER'S MANUAL T0140. Contents Page #
Digital Thermostat residential THERMOSTAT T0140 NON- PROGRAMMABLE up to 2-heat & 1-cool PUMP Stages: 2-Heat, 1-Cool Battery or System Powered Auxiliary Heat Indicator Fahrenheit or Celsius Bi-Color LED
More informationAPCETHD. Specs 1. Basic Description 1. Installation 2. Photocell sensitivity 2. Button Functions 3-4. Error LEDs 5. Factory Settings 6.
Specs 1 Basic Description 1 Installation 2 Photocell sensitivity 2 Button Functions 3-4 Error LEDs 5 Factory Settings 6 Overview 7 How to customize settings 8-10 Q & A 11 Warning 12 Warranty 15 Page 1
More informationElectric Fireplace Instruction Manual MODELS : 18EF023GRA, 18EF023SRA, 23EF023GRA, 23EF023SRA, 25EF023GRA, 26EF023GRA, 26EF023SRA, 28EF023GRA, 28EF023SRA, 32EF023GRA, 32EF023SRA, 33EF023GRA, 33EF023SRA
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model DS7420 DS7425DLX IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this stove. For your safety, always comply with all warnings and safety
More informationPRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE
PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE MODEL NUMBERS: 23 Electric Stove Quality checked by: Valued Customer, We are pleased that you have chosen to purchase an electric stove manufactured by Dimplex
More informationInstruction Manual Refrigerated Counter Top Displays
Instruction Manual Refrigerated Counter Top Displays This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
More informationXC Portable Air Conditioning
PORTABLE AIR CONDITIONERS XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents
More informationPortable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU
Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.
More information6-SITE SUPER-FLOW SYSTEM Instruction Manual
6-SITE SUPER-FLOW SYSTEM Instruction Manual oxygenpotsystems.com 1-888-XL-YIELD Globally Sourced Components, Fabricated and Assembled in Southern California, U.S.A. Neither Oxygen Pot Systems, Inc. nor
More informationMODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL
USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. AUTO Heat Pump & Heat Cool Dual Setpoint
More informationUtopian Portable A/C
Utopian Portable A/C Thank you for purchasing this quality Portable A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any
More informationINSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1400 3 Heating and 2 Cooling with Humidification and De-humdification
More informationMICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L
MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER Installation and Operation Manual MICROtrac Warranty Pulsafeeder, Inc. warrants MICROtrac control systems (including the conductivity sensor) of
More informationINSTRUCTION MANUAL. Full Size Gas Convection Oven
INSTRUCTION MANUAL Full Size Gas Convection Oven This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
More informationTECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.
ORKA TECHNOLOGY CORP. Taking a bite out of energy costs Instruction Manual for the ORKA Remote Thermostat/Humidity Controller Model # RFTH-100 Thank you for your purchase of Orka Technology s RFTH-100
More informationPRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205
PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205 Serial Number Quality checked by: Model Number CAT Number Valued Customer, We are pleased that you have chosen to purchase an electric
More informationARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL
ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL 1 INTRODUCTION Thank you and congratulations for choosing Hamilton products. For over 20 years Hamilton has been providing aquarium lighting and leads the
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationPlease Keep This Manual For Future Reference REV.01
CS-25IR-BLK CS-25IR-CRM CS-25IR-BRZ CS-25IR-GM 1-855-571-1044 Please Keep This Manual For Future Reference REV.01 M PACKAGE CONTENTS A C B PART DESCRIPTION QUANTITY A Body 1 B Leg 4 C Remote Control 1
More information1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24
OWNER'S MANUAL P/N P374-1000FM 1 For All Programmable or Non-Programmable Switchable Digital Thermostat 72 74 Am AUTO 70 Mounts Flush to the Wall 1 Day Programmable or Non-Programmable 4 Time Periods per
More informationPORTABLE AIR CONDITIONER OWNER S MANUAL
PORTABLE AIR CONDITIONER OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS MODELS: JHS-A018-10KR SKU#: 130004 JHS-A018-12KRH SKU#: 130005 WARNING: Read and follow all warnings and instructions in this
More information11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International
11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.
More informationRoom Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.
Instruction Manual Room Monitor model 00276RM CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Placement Guidelines... 5 Using the
More informationModel No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions
Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable
More informationPortable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions
Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions 3092402 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner
More informationMANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier
MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250
More information5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08
Digital Thermostat residential THERMOSTAT 5+2 DAY PROGRAMMABLE up to 2-heat & 1-cool HEAT PUMP Stages: 2-Heat, 1-Cool Battery or System Powered Auxiliary Heat Indicator Back-Lit Digital Display Fahrenheit
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model DF2524L DF2524G 6908921359 6908921459 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Models CS4416 CS3311 CS2307 CS3311 Pictured IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this stove. For your safety, always comply with
More information13500 BTU RV Air Conditioner Installation and Operating Instructions
13500 BTU RV Air Conditioner Installation and Operating Instructions Model No.:HCB-R135-A-ID HCB-R135-A-OD 3092402 V140804 Thank you for choosing a Soleus Air RV Air Conditioner. This owner s manual will
More informationThermometer model 02059
Instruction Manual Thermometer model 02059 pm CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensor... 2 Features & Benefits: Display... 3 Setup...
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationThe Portable Baptistry TM. Electric Heater
The Portable Baptistry TM Electric Heater Specifications and Safety Information 120V / 240V Convertible Thermostat controlled GFCI Protected (120V) 120V = 1500 W/12.5A 240V = 6000W/25A The Portable Baptistry
More informationCR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions
OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com
More informationPOLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL
POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page
More informationMIGHTY PRO 1/4 HP CHILLER
1 MIGHTY PRO 1/4 HP CHILLER FOR TANKS UP TO 170 GALLONS TOP QUALITY & HIGHLY EFFICIENT INTEGRATED DUAL STAGE THERMOSTAT 2 ASSEMBLY PARTS FRONT TOP VIEW BACK 3 SET UP INSTRUCTIONS 1. Remove chiller and
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model DF2024L DF2024CR 6908891459 6908891559 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply
More informationModel No.: PS08-01 PS10-01 Ref: KY80 KY100
8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable
More informationWATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector
WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL
More informationNon-Programmable Digital Thermostat
OWNER'S MANUAL MODEL P474-0140 Non-Programmable Digital Thermostat HEAT PUMP THERMOSTAT 2 HEAT, 1 COOL emergency aux. heat normal energy save Fan On Fan Auto Millivolt Compatible Battery or System Powered
More informationI2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL
USERS INFORMATION MANUAL Heating & Cooling Systems L TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. Mo 72 74 AUTO HEAT 70 Heat Pump &
More informationBlade Series Heat Exchanger Operation and Installation
Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information
More informationMGC Dock User s Manual
Operator s Manual Contents Warnings Statements/Avertisseement... 3 READ FIRST BEFORE OPERATION... 3 Basic Operation... 4 Clip Dock Components... 4 LEDs... 4 Operation... 5 Turning the Clip Dock On and
More informationThermometer with Wired Sensor
Instruction Manual Thermometer with Wired Sensor model 02042 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Setup... 4 Temperature Units...
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM D-tect Systems 11814 South Election Road, Suite 200 Draper, UT 84020 www.dtectsystems.com 1 Introduction The mini
More informationHoneywell Temperature & Humidity Sensor with LCD
Honeywell Temperature & Humidity Sensor with LCD TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 BEFORE YOU BEGIN 5 BATTERY INSTALLATION 7 LOW BATTERY WARNING 7 PLACEMENT OF THE REMOTE SENSOR 7 GETTING
More informationInstruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W
Energy- Saving Mode Window AC 12000BTU MODEL: 12000BTU 11.2 Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction
More informationSingle Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3
Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:
More informationOWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference
3100 Premier Series Non-Programmable 2 Heat / 2Cool & Heat / Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages
More informationOwner s Manual. Filterless UV Air Purifier. This Manual Includes:
Filterless UV Air Purifier Item No. 203758 Owner s Manual This Manual Includes: Warranty Safety Warnings Operating Instructions Replacement Directions Troubleshooting Tips Cleaning and Maintenance Tips
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual before
More informationPRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE
PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE Serial Number Quality checked by: Model Number CAT Number Valued Customer, We are pleased that you have chosen to purchase an electric fireplace
More informationFan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.
Mode 0F Cool Dry Temp Fan Speed Timer 0n/0ff Money Saver Mode 0F hr Fan Cool Only Dry Temp Auto Swing Power Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power For inner cleaning, contact
More informationMODEL (Single Door) MODEL (2 Door pass through)
FOOD WARMING/MERCHANDISING CABINET MODEL 680-1 (Single Door) MODEL 680-2 (2 Door pass through) This warmer provides bottom heat to keep crusts crisp. The illuminated shelves are thermostatically controlled
More informationINSTRUCTION MANUAL P Heating and 1 Cooling
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:
More informationOWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference
3000 Premier Series Non-Programmable Single Stage /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationDocument No
CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Revillusion Built-in Electric Firebox Model RBF30 (6909780100) Model RBF36 (6909790100) Model RBF36P (6909790200) Model RBF42 (6909800100) IMPORTANT SAFETY INFORMATION: Read this manual
More informationTL-105 COLUMN HEATER
TL-105 COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com
More information240 ASSEMBLY & OPERATION MANUAL
WineKoolRTM 240 Read the "USE and CARE" guide before you start! LOCATING YOUR WINE CELLAR Provide 2 1/2 Never locate your wine cellar outdoors or in an area with extremes of temperature and humidity. These
More informationHDS-1000W Hot Dog Steamer
HDS-1000W Hot Dog Steamer This manual contains important information regarding your Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure
More informationPortable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217
Portable Air Conditioner with Heat Pump Technology Operating Instructions 3092402 Model No.: HCB-P13HP-D Reference No.: BPD13HP V140217 Thank you for choosing a Soleus Air Portable Air Conditioner with
More informationProjection Alarm Clock USER GUIDE
Projection Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME, Warnings
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationPlease Keep This Manual For Future Reference REV.01
ELCG347 ELCG240 1-855-571-1044 Please Keep This Manual For Future Reference REV.01 IMPORTANT INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk
More informationOwner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00
Owner s Manual Electric Umbrella Heater Model Number: PUH1500 Quality checked by: Model Number Part Number 7209650100R00 CONTENTS PAGE 1 PAGE 2 PAGE 5 PAGE 6 PAGE 6 Important Instructions Unpacking and
More information