Level I Chapter 1 Worksheet

Size: px
Start display at page:

Download "Level I Chapter 1 Worksheet"

Transcription

1 Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the Plumbing Code shall apply to: a. installations b. alterations and repairs c. replacements d. all of the above 3. The provisions of the Plumbing Code shall NOT apply to: a. Gas-fired water heaters b. Water heater venting systems c. Fuel gas piping d. All of the above 2012 NC Plumbing Code Level 1 Page 1 of 33 Revised: 10/2016

2 Chapter 1 Answer Key 1. C D D NC Plumbing Code Level 1 Page 2 of 33 Revised: 10/2016

3 Chapter 2 Worksheet 1. means having direct access without the need of removing any panel, door or similar covering of the item described, and without requiring the use of portable ladders, chairs, etc. a. Access To b. Direct Vent c. Durham System d. Ready Access 2. A is the drain from the trap of a fixture to the junction of that drain with any other drain pipe. a. Horizontal Branch b. Fixture Drain c. Combination Fixture d. Building Drain 3. is a vertical vent pipe installed primarily for the purpose of providing circulation of air to and from any part of the drainage system. a. Durham System b. Stack Vent c. Vent Stack d. Soil Probe 4. is a device which prevents back-siphonage of water by admitting atmospheric pressure through ports to the discharge side of the device. a. Trap b. Flushometer Value c. Interceptor d. Vacuum Breaker 2012 NC Plumbing Code Level 1 Page 3 of 33 Revised: 10/2016

4 5. is that part of the lowest piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of the building and conveys it to the building sewer 10 ft. outside the building wall. a. Building Sewer b. Building Drain c. Building Stack d. Building Trap 6. is the length of a pipe along the center line of the pipe and fittings. a. Determined Length b. Developed Length c. Desired Length d. Center Length 7. is any pipe or fittings which makes an angle of more than 45 degrees with the vertical. a. Horizontal Pipe b. Vertical Pipe c. Inclined Pipe d. Offset Pipe 8. is the pipe from the water main, water meter, water supply system or other approved source of water supply, to the building or structure served. a. Water Service Pipe b. Water Distribution Pipe c. Water Supply Pipe d. Water Outlet 2012 NC Plumbing Code Level 1 Page 4 of 33 Revised: 10/2016

5 Chapter 2 Answer Key 1. D 2. B 3. C 4. D 5. B 6. B 7. A 8. A 2012 NC Plumbing Code Level 1 Page 5 of 33 Revised: 10/2016

6 Chapter 3 Worksheet 1. The joints at the roof and around vent pipes shall be made watertight by. a. Sealants b. Listed Sealant Materials c. Lead, copper, galvanized steel, aluminum, plastic, or other approved flashing materials. d. None of the above 2. Waste and soil pipes leaving a building shall have an earth cover of inches. a. 12 b. 18 c. 6 d A manhole in a flood-hazard zone (A Zone) shall be sealed unless. a. The manhole has a vent b. The manhole has an air admittance valve c. The manhole is inaccessible d. The manhole is elevated above base flood elevation 4. Temporary toilet facilities need not be on site for crews on a job site for no more than which of the following? a. 2 hours b. one day c. one week d. 2 days 5. Strainer plates on drain inlets shall be designed with openings not greater than. a. 0.5 inch b inch c inch d inch 6. A sleeve passing through a wall to protect piping shall be which of the following? 2012 NC Plumbing Code Level 1 Page 6 of 33 Revised: 10/2016

7 a. A relieving sleeve b. A metal sleeve larger than the pipe c. Two pipe diameters greater than the pipe d. A minimum of two inches larger than the pipe 7. All plastic pipe, fittings and components shall be third party certified as conforming with which of the following? a. NSF 15 b NSF 18 c. NSF 16 d. NSF All openings around pipes, tubing, wiring, conduit, etc. shall be firestopped according to which of the following? a. Building Code b. Fire Code c. Electrical Code d. Mechanical Code 9. The top of water pipes, installed below grade outside the building, shall be: a. Above the frost line b. Minimum 12 feet below finished grade c. Maximum 12 inches below finished grade d. Below the frost line or minimum of 12 inches below finished grade whichever is greater. 10. Water piping installed in an unconditioned area shall be insulated with a minimum R factor of: a b c d Trenches installed parallel to footings shall not extend below the bearing plane of the footing: a. 40 degrees b. 45 degrees c. 50 degrees d. 55 degrees 12. Exterior wall openings shall be made which of the following? a. gas tight b. rain tight c. sealed tight 2012 NC Plumbing Code Level 1 Page 7 of 33 Revised: 10/2016

8 d. water tight 13. Notches on the ends of joints shall not exceed: a. 1/4 the depth b. 1/3 the depth c. 1/2 the depth d. 3/4 the depth 14. The edge of a bored hole in a stud shall be no closer to the edge than: a. 3/8" b. 1/2" c. 5/8" d. 3/4" 15. Protective shield plates shall extend at least which of the following above the sole plate? a inches b. 1.5 inches c. 3 inches d. 2 inches 16. When backfilling above a pipe is complete, which of the following is the proper depth above the crown of the pipe? a. 6 inches b. 8 inches c. 12 inches d. 18 inches 17. When testing the water distribution system which of the following shall be used when testing plastic piping? a. air b. air or water c. air and water d. water 18. In toilet rooms used by five year olds, which of the following may be omitted? a. Toilet stall enclosures b. Toilet stall doors c. Partitions between toilets d. All of the above 2012 NC Plumbing Code Level 1 Page 8 of 33 Revised: 10/2016

9 19. One inch copper tube shall be supported vertically at intervals not exceeding: a. 4 feet b. 6 feet c. 8 feet d. 10 feet 20. CPVC 1" pipe shall be supported horizontally at intervals no more than: a. 2 feet b. 3 feet c. 4 feet d. 5 feet 21. All the piping of the plumbing system shall be tested with: a. Water b. Air c. Soap d. Water or air 22. Drainage piping when tested with water shall be subjected to which of the following? a. 5 feet head of water b. 10 feet head of water c. 15 feet head of water d. 20 feet head of water 2012 NC Plumbing Code Level 1 Page 9 of 33 Revised: 10/2016

10 Chapter 3 Answer Key 1. C D D #6 4. B A C D A D C B D A 307.2, F C 307.2,F101.3 CONVERT TO INCHES 15. D C D D EXCEPTIONS 19. D T B T D B NC Plumbing Code Level 1 Page 10 of 33 Revised: 10/2016

11 Chapter 4 Worksheet 1. When calculating occupant load for teachers and staff, fixtures provided for teachers and staff shall be determined by multiplying the number of classrooms by: a b c d Drinking fountains may be installed in which of the following rooms? a. Foyers, bathrooms or bedrooms b. Kitchens, bedrooms or offices c. Storage rooms, offices or bathrooms d. Bathrooms, closets or bedrooms 3. Toilet rooms may be omitted in a modular classroom building when facilities of sufficient capacity for the additional occupants are provided in an adjacent building and located within of horizontal travel distance from the modular classroom. a. 200 feet b. 400 feet c. 500 feet d feet 4. Each compartment of a laundry tray shall have a waste outlet not less than? a. 1 ½ b. 1 ¼ c. 2 d In a group washup, every of rim space shall be considered as a lavatory a. 18 b. 20 c. 22 d NC Plumbing Code Level 1 Page 11 of 33 Revised: 10/2016

12 6. Without using exception the pan in a school shower compartment shall turn up on sides at least inches. a. 2, 3 b. 3, 2 c. 2, 4 d. 3, 4 7. Shower receptacle waste outlets shall be not less than 2 inches in diameter and shall have a strainer. a. plastic b. copper c. galvanized d. removable 8. Water closets for public use shall be of the type. a. public b. open front c. elongated d. commercial 9. There shall be at least clearance in front of the water closet to any wall, fixture, or door. a. 15 inches b. 21 inches c. 30 inches d. 60 inches 10. What would be the minimum number of water closets required in a retail store of no more than 20 people? a. 1 b. 4 c. 2 d A restaurant has a maximum capacity of 80 people. What would be the minimum number of required water closets? a.1 water closets men and 1 water closets women b.4 water closets men and 4 water closets women c. 2 water closets men and 2 water closets women d. 2 water closets men and 3 water closets women 2012 NC Plumbing Code Level 1 Page 12 of 33 Revised: 10/2016

13 12. In a covered mall, what is the maximum travel distance to toilet facilities? a. 100 feet b. 300 feet c. 500 feet d. 200 feet 2012 NC Plumbing Code Level 1 Page 13 of 33 Revised: 10/2016

14 Chapter 4 Answer Key 1. C B A A B B D C B A (2) 11. A AND AND TABLE B NC Plumbing Code Level 1 Page 14 of 33 Revised: 10/2016

15 Chapter 5 Worksheet 1. What standard must a relief valve for an electric residential water heater comply with? a. ANSI Z21.22 b. ANSI Z c. FS W-H d. FS W-H What is the minimum size of the indirect waste pipe from the safety pan under a water heater in an attic? a. ½ inch b. ¾ inch c. 1 inch d. 1 ¼ inch 3. How close does the water cut-off need to be to the water heater? a. 6 feet b. 1 foot c. 3 feet d. 18 inches 4. Gas water heaters installed in a garage shall be installed so that all burners or ignition device are not less than inches above the floor with an exception of listed flammable vapor ignition resistant: a. 6 inches b. 12 inches c. 18 inches d. 24 inches 5. A gas water heater, with the exception of those having direct vent systems, shall not be installed in a(n). a. attic b. bathroom c. kitchen d. crawl space 2012 NC Plumbing Code Level 1 Page 15 of 33 Revised: 10/2016

16 Chapter 5 Answer Key 1. A C C C B NC Plumbing Code Level 1 Page 16 of 33 Revised: 10/2016

17 Chapter 6 Worksheet 1. What is the correct pressure to test the water distribution system? a. 10 psi for 10 minutes b. 100 psi c. 25 psi above working pressure of operation d. not less than working pressure 2. Hot water supply to any fixture unless otherwise specified by manufacture shall be on the right side. a. True b. False 3. Reclaimed and rain water pipe and outlets shall be color coded in what color? a. Yellow b. Red c. Purple d. Blue 4. What is the minimum pressure at the fixture supply outlet for a bathtub? a. 50 psi b. 20psi c. 10 psi d. 5 psi 5. If a water line is located in the same trench, on the same level as the sewer, what must the sewer line be made of? a. PVC b. ABS c. Cast Iron d. All of the Above 6. Minimum working pressure for plastic hot and cold piping material shall be 100 psi at 180 (82 c ) for which material listed below? a. Water service pipe b. Acid waste c. Water distribution pipe d. None of the above 2012 NC Plumbing Code Level 1 Page 17 of 33 Revised: 10/2016

18 Chapter 6 Answer Key 1. B 601.4, B C B TABLE BASED ON FIXTURES SERVED 5. D #2, TABLE C NC Plumbing Code Level 1 Page 18 of 33 Revised: 10/2016

19 Chapter 7 Worksheet 1. What is the minimum size of a building sewer? a. 3 inches b. 4 inches c. 2 inches d. 6 inches 2. Minimum fall shall be not less than per foot or a 2 pipe or per foot for a 4 pipe. a. 1/4 inch : 1/4 inch b. 1/4 inch : 1/8 inch c. 1/8 inch : 1/4 inch d. 1/8 inch : 1/8 inch 3. A pipe or a fitting which makes an angle of not more than 45 with the vertical is considered a. a. Vertical pipe b. Horizontal pipe c. Vertical and Horizontal pipe d. 90 angle 4. Cleanouts in 4 inch building sewer shall be located not more than apart. a. 50 ft. b. 75 ft. c. 80 ft. d. 100 ft. 5. Size of cleanouts for a 4 inch pipe or larger may be served by a cleanout. a. 4 inch b. 2 inch c. size of pipe d. 3 inch 2012 NC Plumbing Code Level 1 Page 19 of 33 Revised: 10/2016

20 6. Cleanouts for less than a 4 inch pipe shall be. a. 4 inch b. 2 inch c. size of pipe d. 3 inch 7. Man holes are required in 8 inch lines at intervals not more than. a. 100 ft. b. 200 ft. c. 300 ft. d. 400 ft. 8. For the purpose of rodding, cleanout clearance shall be for 8 inch pipe or larger and for 6 inches and smaller. a. 36 inches : 18 inches b. 12 inches : 18 inches c. 18 inches : 12 inches d. 18 inches : 18 inches 9. How many fixture units does a 3 inch trap have? a. 5 b. 3 c. 6 d Fixture units for a shower, a private water closet, and lavatory equals. a. 7 b. 8 c. 6 d Figure Fixture Units for : 3 lavatories, 4 water closets( flushometer tank) and 3 wall urinals (> 1 gal/flush). a. 27 b. 34 c. 31 d What is the minimum size Building Drain for 3 public water closets at ¼ fall? a. 3 inch b. 4 inch c. 5 inch d. 2 1/2 inch 2012 NC Plumbing Code Level 1 Page 20 of 33 Revised: 10/2016

21 13. For 3 flushometer water closets and 4 lavatories, what is the minimum size pipe at 1/4 fall? a. 4 inch b. 3 inch c. 2 inch d. 5 inch 14. What is the maximum number of fixture units that can be put on a two inch branch with ¼ /ft drop and connected to the building drain? a. 10 b. 6 c. 21 d What size horizontal fixture branch is needed to serve 3 water closets (flushometer)? a. 3 b. 4 c. 2 1/2 d For question # 16, how many fixture units? a. 13 b. 12 c. 17 d A total of 7 water closets in a 4 story building, what is the size of the pipe for the stack? a. 2 1/2 b. 3 c. 4 d Waste water from a sump or ejector when discharged into the building drainage system shall be a temperature not higher than. a. 120 F b. 130 F c. 110 F d. 140 F 2012 NC Plumbing Code Level 1 Page 21 of 33 Revised: 10/2016

22 19. What is the minimum size discharge for a grinder pump that receives discharge from water closets? a 2 b. 1 ¼ c. 1 ½ d NC Plumbing Code Level 1 Page 22 of 33 Revised: 10/2016

23 Chapter 7 Answer Key 1. B T (1)B 2. B A D A C D A A TABLE C TABLE C TABLE A TABLE 710.1(1) (C) 13. B TABLE 710.1(1) (C) 14. C TABLE & TABLE (1) 15. A TABLE 710.1(2) (G) 16. B TABLE B TABLE 710.1(2) (G) 18. D B (EXCEPTION1) 2012 NC Plumbing Code Level 1 Page 23 of 33 Revised: 10/2016

24 Chapter 9 Worksheet 1. An open vent pipe extending through a roof shall terminate at least above the roof when the roof is used for weather protection only. a. 6 b. 12 c. 2 d What is the minimum size of a main vent stack or stack vent that must be installed in all buildings containing more plumbing than just a washing machine or laundry tray? a. 1 1/2 b. 2 c. 3 d It would be acceptable to install an individual vent for a kitchen sink in the horizontal position before it rises 6 inches above the floor level rim of the sink, since there is normally a window over this sink. a. True b. False 4. The maximum distance from the trap weir to the vent fitting for a fixture with a 1 1/2 inch drain, a 1 1/2 inch trap, and a 1/4 inch fall per foot is. a. 3 6 b. 5 c. 6 d What is the minimum size individual vent for one water closet? a. 1 1/4 b. 1 1/2 c. 2 d. 2 1/2 6. A combination waste and vent system may be used for a hand sink. a. True b. False 2012 NC Plumbing Code Level 1 Page 24 of 33 Revised: 10/2016

25 7. What is the minimum diameter of a 60 foot long vent stack serving a 3 inch soil stack with 35 fixture units? a. 2 c. 3 b. 1/2 d What is the maximum length of a 3 inch stack vent serving a 4 inch waste stack with 90 fixture units? a. 100 b. 200 c. 260 d What is the standard used to govern air admittance valves? a. ANSI/ASSE 1051 b. ASTM C 1053 c. ASTM P2665 d. ANSI B According to the drawing, what size pipe is required for the section marked A? a. 1 1/4 b. 1 1/2 c. 2 d. 2 1/ NC Plumbing Code Level 1 Page 25 of 33 Revised: 10/2016

26 11. According to the drawing, what is the least distance the vents can terminate above the roof? Roof is used for weather protection only. Parapet A B Roof is used as a sun deck. Flat Roof a. A:6 B:4 b. A:5 B:6 c. A:4 B:6 d. A:6 B:7 12. You may have a total of fixture units on a 2 wet vent? a. 6 b. 4 c. 12 d On a three inch waste stack the stack vent must be. a. 2 b. 1.5 c. 3 d If an air test is performed on the vent system, it must be tested at psi for minutes. a. 10 for 10 b. 10 for 5 c. 5 for 15 d. 5 for NC Plumbing Code Level 1 Page 26 of 33 Revised: 10/2016

27 15. A horizontal branch vent shall be at least inches above the flood level rim of the highest fixture served. a. 2 b. 4 c. 6 d A 2 trap with a 2 drain, the vent must be no further than inches from the trap weir. a. 60 b. 72 c. 84 d The maximum of fixtures connected to a horizontal fixture branch drain shall be permitted to be circuit vented. a. 8 b. 12 c. 20 d Air admittance valves shall conform to standard. a. ANSI/ASSE 1051 b. ANSI/ASSE 1001 c. ANSI/ASSE 1001 d. ANSI/ASSE NC Plumbing Code Level 1 Page 27 of 33 Revised: 10/2016

28 Chapter 9 Answer Key 1. A B B C T B A A T B T A B D B C C C D A A NC Plumbing Code Level 1 Page 28 of 33 Revised: 10/2016

29 Chapter 10 Worksheet 1. What is the maximum center line distance between 3 single compartment sinks served by 1 trap? a. 24 b. 30 c. 60 d What is the maximum vertical distance from the fixture outlet to trap weir for a kitchen sink? a. 48 b. 12 c. 24 d Where food waste grinders are installed, the waste from those units shall discharge directly into the Building drainage system after passing through a solids interceptor and grease interceptor. a. True b. False 4. A fixture shall not be double trapped. a. True b. False 5. Traps shall be set level with respect to their water seals. a. True b. False 2012 NC Plumbing Code Level 1 Page 29 of 33 Revised: 10/2016

30 Chapter 10 Answer Key 1. B EXCEPTION #2 2. C B A A NC Plumbing Code Level 1 Page 30 of 33 Revised: 10/2016

31 Chapter 11 Worksheet 1. When roof drains are provided they shall have strainers extending not less than inches above the surface of the roof immediately adjacent to the drain. a. 3 b. 4 c. 5 d What is the maximum projected roof area that a 4 inch vertical leader can handle with a 4 inches per hour rainfall? a. 18,400 square feet b. 9,200 square feet c. 6,130 square feet d. 4,600 square feet 3. A roof has an area of 4,600 square feet. What is the minimum size horizontal drain required if it has 1/4 per foot fall and 4 inches per hour rainfall? a. 4 b. 5 c. 6 d Secondary roof drain systems are sized according to what rain flow rate? a. 100 year, 15 minute precipitation b. 100 year, 60 minute precipitation c. 60 year, 15 minute precipitation d. 60 year, 60 minute precipitation 5. The sump pit shall not be less than inches deep and inches in diameter unless otherwise approved. a. 18,20 b. 12, 24 c. 20, 10 d. 24, NC Plumbing Code Level 1 Page 31 of 33 Revised: 10/2016

32 6. Which of the following shall not be connected to a storm drain? a. Roof leaders b. Floor drains c. Area drains d. Roof conductors 2012 NC Plumbing Code Level 1 Page 32 of 33 Revised: 10/2016

33 Chapter 11 Answer Key 1. A D (1) 3. B A F (A) 5. D B NC Plumbing Code Level 1 Page 33 of 33 Revised: 10/2016

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

MATERIALS Traps TRAPS. No. IPC IRC Description

MATERIALS Traps TRAPS. No. IPC IRC Description MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016 Ohio Administrative Code Rule Number OPC Section IPC origin Reason for proposed 4101:3-2-01 Alternate on-site 2015 Added definition

More information

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof. CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern

More information

Building Utilities 1 Plumbing and Sanitary Systems

Building Utilities 1 Plumbing and Sanitary Systems Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

1 Exam Prep Plumbing State Contractors Practice Exam 2

1 Exam Prep Plumbing State Contractors Practice Exam 2 1 Exam Prep Plumbing State Contractors Practice Exam 2 1 According to Chapter 64E-6, when sizing a grease interceptor used in a restaurant, the correct formula is. A. (S) x (EW 12) x (LF) B. (S) x (GS)

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. The minimum air gap for a fixture with an effective open of 1/2", located away from a

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING Test Code: 5924 Version: 01 Specific competencies and skills tested in this assessment: Safety Follow rules for fire safety Follow rules for housekeeping

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION................1 101.0 Title, Scope, and General...........1 101.1 Title............................1 101.2 Purpose.........................1 101.3 Plans Required...................1

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS PLUMBING REQUIREMENTS This handout is a compilation of the standard requirements based on the State Plumbing Code and City Ordinance for projects of this type. This information sheet does not contain all

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

CHAPTER VI BUILDING PLUMBING

CHAPTER VI BUILDING PLUMBING CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

ENERGY MARKETING SERVICES

ENERGY MARKETING SERVICES 1 IMPORTANT STUFF This manual has been designed as a supplemental aid for students preparing to take the Plumbing Exam based on the international codes. It is not intended to replace any manuals or material

More information

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.0 General. 2015 UPC CODE - CHAPTER 8 INDIRECT WASTES 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Test Code: 8117 / Version 1

Test Code: 8117 / Version 1 Pennsylvania Customized Assessment Blueprint Plumbing Technology/Plumber PA Test Code: 8117 / Version 1 Copyright 2012. All Rights Reserved. General Assessment Information Plumbing Technology/Plumber PA

More information

2009 IPC ,IMC Q &A ANDIFGC

2009 IPC ,IMC Q &A ANDIFGC 2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Denotes a new question! Denotes a revised/revisited question. September 2009 General: General: 1) (Q) What does a contractor/permit holder have to supply for an inspection? (A) Section 107.2 of the NC Administrative Code states that it is the duty of the permit holder to provide access

More information

TABLE OF CONTENTS. Part I Administrative... 1

TABLE OF CONTENTS. Part I Administrative... 1 Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

Chapter 4: Fixtures, Faucets & Fittings:

Chapter 4: Fixtures, Faucets & Fittings: Table of Contents Chapter 1 Administration 0 Chapter 2 Definitions 0 Chapter 3 General Regulations 0 Chapter 4 Fixtures, Fau & Fit. 12 Chapter 5 Water Heaters 14 Chapter 6 Water Supply & Dist. 10 Chapter

More information

APPENDIX L ALTERNATE PLUMBING SYSTEMS

APPENDIX L ALTERNATE PLUMBING SYSTEMS ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate

More information

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock. Plumbing Plumbing may be defined as practice, materials, and fixtures used in the installation, maintenance, and alteration of all piping, fixtures, appliances, and appurtenances in connection with sanitary

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General... TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

PLUMBING FIXTURES Reserved

PLUMBING FIXTURES Reserved CHAPTER 27 PLUMBING FIXTURES Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 395R This page left intentionally blank. 396R 2003 INTERNATIONAL RESIDENTIAL CODE SECTION P2708 SHOWERS P2708.1 General. Shower

More information

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures 4. SANITARY PLUMBING FULLY VENTED SYSTEM On completion of this module, the student should be able to: Design, install and develop bills of quantities for a fully vented modified system for commercial and

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DOMESTIC WATER PACKAGED BOOSTER PUMPS DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot

More information

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire Suppression Systems; and Chapter 34-National Electric

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC People Helping People Build a Safer World Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC Installation, Flexibility and Opportunity for Savings Lee Clifton, Senior Director of PMG Resources,

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION.............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training 2012 Virginia Plumbing Code & VRC (Plumbing) Update Training ----------------------------- Henrico County Department of Building Construction and Inspections Introduction This presentation was prepared

More information

Plumbing Technology/Plumber CIP Task Grid

Plumbing Technology/Plumber CIP Task Grid 1 Secondary Task List 100 DEMONSTRATE PERSONAL SAFETY IN THE TRAINING LABORATORY 101 Follow rules for fire safety. 102 Follow rules for housekeeping safety. 103 Follow shop rules. 104 Follow rules for

More information

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

CHAPTER 2 DEFINITIONS

CHAPTER 2 DEFINITIONS CHAPTER 2 DEFINITIONS 201 GENERAL 201.1 Scope For the purpose of this code, certain abbreviations, terms, phrases, words and their derivatives shall be construed as set forth in this chapter or the chapter

More information

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia Pro Vent TM Guide to Design and Usage Provent Single System Handling Installation Corrosion Ease Simplicity Resistance IPMO Copyright (c) 2014, Pro Vent Systems Inc., plus *2016 Revisions ll Rights Reserved

More information

2. Sanitary Plumbing General Installation Requirements

2. Sanitary Plumbing General Installation Requirements 2. Sanitary Plumbing General Installation Requirements On completion of this section, students should be able to: Identify and describe sanitary plumbing installations requirements in accordance with the

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION PC 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.

More information

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT DATE OF AUTHORIZATION June 28, 2001 BMEC REFERENCE BMEC # 01-07-259 BMEC APPLICATION # BMEC #A 2001-10 OATEY CANADA INC. SURE-VENT AND

More information

FEATURES. Other Fed-Flush Arrangements

FEATURES. Other Fed-Flush Arrangements Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags

More information

A GUIDE TO PASSING THE PLUMBING EXAM

A GUIDE TO PASSING THE PLUMBING EXAM A GUIDE TO PASSING THE PLUMBING EXAM BASED ON THE INTERNATIONAL PLUMBING AND FUEL GAS CODES WRITTEN BY JOHN WHITE REVISED 2014 2007-2014 This manual is the sole property of Energy Marketing Services. No

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office

More information

PLAN REVIEW SUBMITTAL GUIDE

PLAN REVIEW SUBMITTAL GUIDE PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide

More information

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what This practice exam will require you to have a calculator, pencil, scrap paper, a copy of the 2005 National Plumbing Code and will contain many similar questions as the current Plumbing Red Seal trade certification.

More information

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. You can complete the test by printing a hard copy, or

More information

Code verification sign-off

Code verification sign-off Code verification sign-off Following is a list of the most common manufactured home code non-compliant items found in used or altered manufactured homes. These are only the most commonly found items and

More information

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS City of Redwood City Community Development Department Building and Inspection Department 1017 Middlefield Road Redwood City, CA 94063 Phone (650) 780-7350 2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY

More information

2015 MPC, MMC and IFGC Significant Changes

2015 MPC, MMC and IFGC Significant Changes 2015 MPC, MMC and IFGC Significant Changes Based on the 2015 Michigan Plumbing Code, (MPC), the 2015 Michigan Mechanical Code (MMC) and the 2015 International Fuel GaS Code (IFGC) Purpose This program

More information

Plumbing Guidelines 2012 IBC/ANSI A

Plumbing Guidelines 2012 IBC/ANSI A Plumbing Guidelines 2012 IBC/ANSI A117.1-2009 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms and bathing facilities. It is not intended to replace

More information

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

WATER HAMMER ARRESTORS & MISC. SPECIALTIES TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations

More information

Inspection Checklist Mechanical Final

Inspection Checklist Mechanical Final Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and

More information

DEFINITIONS CHAPTER 2

DEFINITIONS CHAPTER 2 CHAPTER 2 DEFINITIONS SECTION 201 GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. 201.2

More information

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

INSPECTION OF COMMERCIAL KITCHEN PLUMBING INSPECTION OF COMMERCIAL KITCHEN PLUMBING 801.1 SCOPE Food-handling establishments 2 - by John Williams, Jr. Plumbing Control Supervisor Onondaga County Water Environment Protection Commercial Kitchens

More information

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA AMERICAN PLUMBING INSTITUTE 2015 33 CONTINUING EDUCATION PO Box 31131 Spokane, WA 99223-3018 www.apiceu.com 2009 UPC Definitions Code Course 4 hours Course # ID09143 (CODE) DISCLAIMER NOTE: This course

More information

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition 2015 SCHEDULE COMMUNITY DEVELOPMENT DEPT. ENGINEERING PLAN REVIEW Single Family New Construction All Other Plan Reviews Minimum Engineering Fee Planned Unit Development - PUD: Step #1: Step #2: See Site

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space? NEW CASTLE COUNTY DEPARTMENT OF LAND USE FAQ (Frequently Asked Questions) What is required to convert my unfinished basement to finished space? 1. To convert an unfinished basement to finished space, at

More information

2015 IPC, IMC and IFGC Significant Changes

2015 IPC, IMC and IFGC Significant Changes Accreditation 2015 IPC, IMC and IFGC Significant Changes Based on the International Plumbing Code (IPC ), the International Mechanical Code (IMC ) and the International Fuel Gas Code (IFGC ) The International

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18 NAVFAC PTS-D20 (February 2018) ------------------------------ Preparing Activity: NAVFAC SUPERSEDING PTS-D20 (September 2016) PERFORMANCE TECHNICAL SPECIFICATION SECTION D20 PLUMBING 02/18 NOTE: This section

More information

2012 UPC Chapter 5 Water Heaters RV

2012 UPC Chapter 5 Water Heaters RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

How To Size A Big Dipper Unit

How To Size A Big Dipper Unit Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size

More information

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code ProVent Systems Plumbing Fundamentals Educational Literature Comparison of ProVent Design Rules and The International Plumbing Code Guide to Contents Topics and Descriptions Page Interior views of the

More information

LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION

LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION CHAPTER 23.25 LOCAL AMENDMENTS TO THE UNIFORM PLUMBING CODE 2012 EDITION Sections 23.25.100 Local amendments to the Uniform Plumbing Code, 2012 Edition. 2 23.25.102-103 Delete.... 3 23.25. 204.0 "B" definitions....

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub. CHAPTER 2 DEFINITIONS 201.0 General. For the purpose of this code, the following terms have the meanings indicated in this chapter. No attempt is made to define ordinary words which are used in accordance

More information

Schedule of Fees Schedule B

Schedule of Fees Schedule B Schedule of Fees Schedule B BUILDING DEPARTMENT 2. Building Permit* $65.00 for value or valuation up to $1,000. After $1,000 of value $8.00 per $1,000. After $1,000,000 of value $6 per $1,000 3. Demolition

More information

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod Journeyman and Master Common Exam 2 1 The grounding terminal of a grounding-type receptacle installed in a metal box shall be? A. Connected to the equipment ground B. Bonded to the box C. Connected to

More information

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products. Wastewater Guidelines for Sizing Features These guidelines cover the steps which need to be taken to accurately select the correct sewage pump and applicable systems to use in sewage ejectors. Work through

More information

REQUIREMENTS & GUIDELINES

REQUIREMENTS & GUIDELINES SMALL CENTERS IN A RESIDENCE (6-12 Children) REQUIREMENTS & GUIDELINES Mecklenburg County Code Enforcement and the North Carolina Department of Health and Human Services Division of Child Development are

More information

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER E LAA limited alteration application - FILING GUIDE information you need to know Bill de Blasio, MAYOR build safe live safe Rick D. Chandler P.E., COMMISSIONER FIXTURES COMMENTS efile Backflow Preventer

More information

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division These Notes are intended to assist in issuing simple remodel permits. It provides information on the most common requirements relating to the construction or remodeling of kitchens, bathrooms and bedrooms.

More information

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors. You can complete the test by printing a hard copy, or

More information