Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting

Size: px
Start display at page:

Download "Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting"

Transcription

1 FP Series s BECKETT OEM OIL BURNER CONFIGURATION Burner Model ATC Head Type Head setting/ firing pin Nozzle or Gas Orifice Size Air Pump or Manifold Pressure Baffle Solenoid Valve Flange Flange Insertion depth Flange Pitch Flange Rotation FP 24 Oil AFII HLX5HB 6-slot 4.65 X 6 o B (H) 4. 16(psig) None /8 1 o o FP 24 Oil AFII HLX5HB 6-slot 6.85 X 45 o B (H) (psig) None /8 1 o o FP 24 Oil AFII 15 HLX5HB 6-slot 4.85 X 45 o B (H) (psig) None None /8 1 o o FP 24 Oil AFII 15 HLX5HB 6-slot 6 1. X 45 o B (H) 5. 16(psig) None None /8 1 o o Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

2 SPECIFICATIONS FOR DYNATHERM FPB MODELS 24 & 36 WITH CARLIN SERIES 99CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 99-48CRD BURNER FPB MODELS 24 & 36 WITH CARLIN SERIES CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 11-48CRD BURNER RECOMMENDED SETTINGS FOR 99 CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS BLANK AIR SHUTTER RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 48 FPB BOILER OPEN AIR SHUTTER Air Band % Air Band %.85 1/ / / / / / / / /16 6 RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS WITH DELAY OIL VALVE RECOMMENDED SETTINGS FOR CRD MODEL 48 FPB WITH 5-1/16" DIA. BLOWER WHEEL NO DELAY OIL VALVE Air Shutter Air Band Air Shutter Air Band.85 Min. 1/8 Max. 1/4 1. Min. 3/16 Max. 5/ Min. 3/32 Max. 1/ Min. 7/16 Max. 9/ / / Min. 7/16 Max. 9/ Min. 7/16 Max. 5/8 5 2 NOZZLE SPECIFICATIONS MODEL 99 CRD AND CRD MODEL CRD AND CRD 45 o semi-solid Hago 45 o Steinen Q 45 o Monarch R 45 o Monarch AR 45 o Steinen S

3 RATINGS & DATA Gross Output MBH D.O.E. A.F.U.E. Efficiency % Nozzle Size Gross Stack Temperature F Net Hot Water MBH Net Hot Water Sq.Ft. 24A B C A B C A B C FP/B MODEL WEIGHTS AND DIMENSIONS LENGTH SHIPPING INSTALLATION CLEARANCE WEIGHT CRATED VERTICAL SIDE FRONT REAR BARE BOILER SKID JACKET BURNER WIDTH HEIGHT 24 23" 35" 33" 13" 19" 34" 555 6" 12" 18" 24" 36 35" 47" 44" 13" 19" 34" 665 6" 12" 18" 24" 48 47" 59" 56" 13" 19" 34" 775 6" 12" 18" 24" DOMESTIC WATER OUTPUT Standard Equipment MODEL Intermittent G.P.M. Continuous G.P.H. Flame Retention Oil Burner Flush Jacket Insulation 24A Primary Control Dual Connections for Temperature & Vent & Return Piping 24B Pressure Gauge Oil Valve 24C Water Features Tankless Coil 36A Combination High Limit/Low Limit Operating Control and Circulator Relay 36B 4 29 Steam Features 36C Low Water Cutoff Operating Control Safety Valve Water Gauge 48A 5 24 Pressure Control Compound Gauge 48B 5 26 Optional Equipment Two-Stage Fuel Unit Tankheater Coil 48C 5 27 Dual Tankless Coil Jacket Extension 43 E CHERRY RD, QUAKERTOWN PA (215) FAX: (215) VISIT OUR WEB SITE AT WWW. DYNATHERMBOILER.COM

4 DYNATHERM FP Series s CARLIN OEM GAS BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Pre/Post Purge Natural Gas orifice Natural Gas Air Propane Orifice Propane Air FP 18 Gas EZ-GAS 91 MBH 13/64 15% 9/64 12% FP 18 Gas EZ-GAS 15 MBH #3 (.213 ) 22% 9/64 23% FP 18 Gas EZ-GAS 119 MBH 15/64 32% 11/64 33% FP 18 DV EZ-GAS 91 MBH DV 13/64 5% 9/64 6% FP 18 DV EZ-GAS 15 MBH DV #3 (.213 ) 8% #21 (.159) 8% FP 18 DV EZ-GAS 119 MBH DV 15/64 11% 11/64 12% FP 24 Gas EZ-GAS 119 MBH 15/64 41% 11/64 42% FP 24 Gas EZ-GAS 14 MBH 17/64 6% 13/64 6% FP 24 Gas EZ-GAS 175 MBH 5/16 9% B (.238 ) 9% FP 24 DV EZ-GAS 119 MBH DV 15/64 8% 11/64 11% FP 24 DV EZ-GAS 15 MBH DV 17/64 18% 13/64 18% FP 24 DV EZ-GAS 119 MBH DV 5/16 37% B (.238 ) 28% FP 36 Gas EZ-GAS 175 MBH 5/16 5% B (.238 ) 4% FP 36 Gas EZ-GAS 189 MBH Q (.332 ) 6% F (.257 ) 53% FP 36 Gas EZ-GAS 21 MBH 3/8 83% J (.277 ) 67% FP 36 DV EZ-GAS 175 MBH DV 5/16 37% B (.238 ) 32% FP 36 DV EZ-GAS 189 MBH DV Q (.332 ) 43% F (.257 ) 42% FP 36 DV EZ-GAS 21 MBH DV 3/8 75% J (.277 ) 85% A) 3 ½ Water Column Manifold Pressure B) 4 long orificed nipple used, orifice toward gas valve DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

5 DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Pump or Flange Control Nozzle Size Air Band/ Manifold Insertion Burner Model Head Bar Pre/Post Purge Air Boot Pressure depth FP 18 Oil EZ-1 PRO 622 1/1.55 X 45 o B (psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.65 X 45 o B.65.6/.65 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.75 X 45 o B (psig) 3. to flange FP 18 DV EZ-1 PRO /12.55 X 45 o B.45.6/.65 15(psig) 3. to flange FP 18 DV EZ-1 PRO /12.65 X 45 o B (psig) 3. to flange FP 18 DV EZ-1 PRO /12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.75 X 45 o B (psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.85 X 45 o B.85.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B / (psig) 3. to flange FP 24 DV EZ-1 PRO /12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 DV EZ-1 PRO /12.85 X 45 o B / (psig) 3. to flange FP 24 DV EZ-1 PRO / X 45 o B / (psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1. X 45 o B / 1. 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B / (psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/ X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO /12 1. X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO / X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO / X 45 o B (psig) 3. to flange A) All B oil burner nozzles listed above for EZ-1 Pro Oil burner are Hago or Delavan B) All Air tubes for above burners are 7 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

6 DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement EZ-1/ 99FRD Burner Model Control Nozzle or Gas Orifice Size Air Turbulator or Head setting Pump or Manifold Pressure Flange Insertion depth FP 24 Oil EZ-1HP 62 1/1.75 X 45 o B (psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1 1.1 X 45 o B /1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.75 X 45 o B (psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/ X 45 o B / (psig) 2.75 to flange FP 18 99FRD X 45Q 15%. (psig) 3. to flange FP 18 99FRD X 45Q 25% 1. (psig) 3. to flange FP 18 99FRD X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD X 45Q 25% 1. (psig) 3. to flange FP 24 99FRD X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD X 45Q 55% 2. (psig) 3. to flange FP 36 99FRD X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD X 45Q 75% 3. (psig) 3. to flange FP 42 99FRD X 45Q 8% 3. (psig) 3. to flange C) All B oil burner nozzles listed in above setup chart for EZ-1 Oil burner are Hago or Delavan D) All Q oil burner nozzles listed in above setup chart for 99FRD Oil burner are Steinen E) All Air tubes for above burners are 5 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

7 Nozzle Interchange Chart Spray Angles 3 o through 9 o HAGO/SID HARVEY H A SS (up to 2.) SS SS (over 2.) A or W ES/P B* B B* MONARCH NS/PL A R/AR (up to 2.) R-D/AR-D R/AR (over 2.) A/A or W PLP B* DANFOSS AS W or B AH A *The original B Nozzle

8 Burner Manufacturer s Recommendations* Manufacturer Model Delavan Nozzle F-AFC 8 o W, A or B HF-US 8 o W, A or B Aero Burner HF-AFC 8 o W, A or B SV-SSV 7 o or 8 o B AF/FG (F) 6 o, 7 o or 8 o A or B (-15 PSI) R.W. AF/AFG (M) 6 o or 7 o A or B (-15 PSI) Beckett AFII (FB) 45 o, 6 o or 7 o A, W or B (14-2 PSI) AFII (HLX) 45 o, 6 o or 7 o A, W or B (14-2 PSI) 99 FRD (Std.) GPH 6 o A GPH 45 o A, 6 o A or B CRD (Std.) GPH 6 o A GPH 45 o A, 6 o A or B The Carlin Co. Riello Burners Intertherm Wayne Home Equipment Weil-McLain GPH 6 o Elite EZ GPH 7 o A GPH 6 o SS GPH 6 o or 7 o Elite (EZ-2,3) All Flow s 6 o A, B or SS Mectron 3M 6 o W, B, or Del-O-Flo A 5M (Up to.85 GPH) F3, F GPH 6 o or 8 o W or A F GPH 6 o W or B F15, F GPH 45 o or 6 o W or B R35.3, R GPH 6 o or 8 o W or B Press Series GPH 6 o or 45 o B or W MAC 1265 P/N or.55 GPH 9 o W or.579 MH MSH o A MSH o A P.5 1. GPH 6 o, 7 o, or 8 o A or B EHASR GPH 8 o, 7 o, or 6 o ** MSR GPH 8 o, 7 o, or 6 o ** HS GPH 8 o, 7 o, or 6 o ** HS.5 3. GPH 8 o, 7 o, or 6 o B EG GPH 8 o, 7 o, or 6 o ** **Under 1. GPH use A; above 1. use B QB18 (15 PSI) GPH 45 o, 6 o, 7 o, 8 o A or B QB18 (14 PSI) GPH 45 o, 6 o, 7 o, 8 o B *Effective November Subject to updating by burner manufacturers. For s not listed, contact burner manufacturer. Always follow the appliance manufacturer s instructions for the correct nozzle specification. For more current information, please visit our website at NOTE: Information on this chart is to be used as a general guide only.

9 Recommended Nozzle Sizes for s MODEL BURNER BRAND GPH DEGREE SPRAY RIELLO or 6 SOLID BECKETT AFII 15 HAGO SOLID.85 CARLIN HAGO/ SOLID RIELLO BECKETT AFII 15 CARLIN HAGO HAGO/ or 6 SOLID 45 SOLID 45 SOLID 36 RIELLO BECKETT AFII 15 CARLIN HAGO HAGO/ or 6 SOLID 45 SOLID 45 SOLID 42 RIELLO CARLIN HAGO/ SOLID 45 SOLID 48 RIELLO CARLIN HAGO/ SOLID 45 SOLID

10 DYNATHERM BOILERS DYNATHERM FP Series s RIELLO OEM OIL BURNER CONFIGURATION Appliance Venting arrangement rate input Nozzle or Pump or Flange Burner Model value US Gas Orifice Air Gate Turbulator or Manifold Insertion gph or BTU/Hr. Size Head setting Pressure depth FP 24 Oil 4 F5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 Oil 4 F5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 Oil 4 F5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt X 8 o B (psig) 2.5 to flange FP 24 gas 4 G2 w/sbt 119, 2.mm o w.c. Fixed FP 24 gas 4 G2 w/sbt 14, 2.mm o w.c. Fixed FP 24 gas 4 G2 w/sbt 175, 2.mm o w.c. Fixed FP 48 Oil 4 F1 w/lbt X 3 o B (psig) 2.5 to flange FP 48 Oil 4 F1 w/lbt X 3 o B (psig) 2.5 to flange FP 48 Oil 4 F1 w/lbt X 3 o B (psig) 2.5 to flange FP 48 gas 4 G2 (see note C ) 231, FP 48 gas 4 G2 (see note C ) 28, FP 48 gas 4 G2 (see note C ) 315, NO DATA AVAILABLE A) All oil burner nozzles listed in above setup chart = Delavan B) FP 48 boiler with F1 oil burner utilized a OEM specific milled aluminum type turbulator disk see OEM part number below C) FP 48 boiler with 4 G4 gas burner: No application data available D) All Gas burner installations must have a minimum of 6 of gas supply pressure measured at the inlet of gas valve during a firing cycle to obtain proper input value. E) All chimney applications must utilize a draft regulator (single acting oil) & (double acting gas) and draft pressure in breech to be -.2 to.4 WC F) All OEM configurations and settings listed above are a starting point only. OEM spare parts list 4 F3 4 F5 4 F1 4 G2 4 G4 Flange C6841 C6841 C6841 C6841 N/A Gasket C68819 C68819 C68819 C68819 N/A part # C6563

11 SPECIFICATIONS FOR DYNATHERM FPB MODELS 24 & 36 WITH CARLIN SERIES 99CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 99-48CRD BURNER FPB MODELS 24 & 36 WITH CARLIN SERIES CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 11-48CRD BURNER RECOMMENDED SETTINGS FOR 99 CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS BLANK AIR SHUTTER RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 48 FPB BOILER OPEN AIR SHUTTER Air Band % Air Band %.85 1/ / / / / / / / /16 6 RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS WITH DELAY OIL VALVE RECOMMENDED SETTINGS FOR CRD MODEL 48 FPB WITH 5-1/16" DIA. BLOWER WHEEL NO DELAY OIL VALVE Air Shutter Air Band Air Shutter Air Band.85 Min. 1/8 Max. 1/4 1. Min. 3/16 Max. 5/ Min. 3/32 Max. 1/ Min. 7/16 Max. 9/ / / Min. 7/16 Max. 9/ Min. 7/16 Max. 5/8 5 2 NOZZLE SPECIFICATIONS MODEL 99 CRD AND CRD MODEL CRD AND CRD 45 o semi-solid Hago 45 o Steinen Q 45 o Monarch R 45 o Monarch AR 45 o Steinen S

12 RATINGS & DATA Gross Output MBH D.O.E. A.F.U.E. Efficiency % Nozzle Size Gross Stack Temperature F Net Hot Water MBH Net Hot Water Sq.Ft. 24A B C A B C A B C FP/B MODEL WEIGHTS AND DIMENSIONS LENGTH SHIPPING INSTALLATION CLEARANCE WEIGHT CRATED VERTICAL SIDE FRONT REAR BARE BOILER SKID JACKET BURNER WIDTH HEIGHT 24 23" 35" 33" 13" 19" 34" 555 6" 12" 18" 24" 36 35" 47" 44" 13" 19" 34" 665 6" 12" 18" 24" 48 47" 59" 56" 13" 19" 34" 775 6" 12" 18" 24" DOMESTIC WATER OUTPUT Standard Equipment MODEL Intermittent G.P.M. Continuous G.P.H. Flame Retention Oil Burner Flush Jacket Insulation 24A Primary Control Dual Connections for Temperature & Vent & Return Piping 24B Pressure Gauge Oil Valve 24C Water Features Tankless Coil 36A Combination High Limit/Low Limit Operating Control and Circulator Relay 36B 4 29 Steam Features 36C Low Water Cutoff Operating Control Safety Valve Water Gauge 48A 5 24 Pressure Control Compound Gauge 48B 5 26 Optional Equipment Two-Stage Fuel Unit Tankheater Coil 48C 5 27 Dual Tankless Coil Jacket Extension 43 E CHERRY RD, QUAKERTOWN PA (215) FAX: (215) VISIT OUR WEB SITE AT WWW. DYNATHERMBOILER.COM

13 FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Nozzle or Gas Orifice Size Air Turbulator or Head setting Pump or Manifold Pressure Flange Insertion depth FP 24 Oil EZ-1HP 62 1/1.75 X 45 o B (psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1 1.1 X 45 o B /1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.75 X 45 o B (psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/ X 45 o B / (psig) 2.75 to flange FP 18 99FRD X 45Q 15%. (psig) 3. to flange FP 18 99FRD X 45Q 25% 1. (psig) 3. to flange FP 18 99FRD X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD X 45Q 25% 1. (psig) 3. to flange FP 24 99FRD X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD X 45Q 55% 2. (psig) 3. to flange FP 36 99FRD X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD X 45Q 75% 3. (psig) 3. to flange FP 42 99FRD X 45Q 8% 3. (psig) 3. to flange A) All B oil burner nozzles listed in above setup chart for EZ-1 Oil burner are Hago or Delavan B) All Q oil burner nozzles listed in above setup chart for 99FRD Oil burner are Steinen C) All Air tubes for above burners are 5 in length Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

14 DYNATHERM FP Series s CARLIN OEM GAS BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Pre/Post Purge Natural Gas orifice Natural Gas Air Propane Orifice Propane Air FP 18 Gas EZ-GAS 91 MBH 13/64 15% 9/64 12% FP 18 Gas EZ-GAS 15 MBH #3 (.213 ) 22% 9/64 23% FP 18 Gas EZ-GAS 119 MBH 15/64 32% 11/64 33% FP 18 DV EZ-GAS 91 MBH DV 13/64 5% 9/64 6% FP 18 DV EZ-GAS 15 MBH DV #3 (.213 ) 8% #21 (.159) 8% FP 18 DV EZ-GAS 119 MBH DV 15/64 11% 11/64 12% FP 24 Gas EZ-GAS 119 MBH 15/64 41% 11/64 42% FP 24 Gas EZ-GAS 14 MBH 17/64 6% 13/64 6% FP 24 Gas EZ-GAS 175 MBH 5/16 9% B (.238 ) 9% FP 24 DV EZ-GAS 119 MBH DV 15/64 8% 11/64 11% FP 24 DV EZ-GAS 15 MBH DV 17/64 18% 13/64 18% FP 24 DV EZ-GAS 119 MBH DV 5/16 37% B (.238 ) 28% FP 36 Gas EZ-GAS 175 MBH 5/16 5% B (.238 ) 4% FP 36 Gas EZ-GAS 189 MBH Q (.332 ) 6% F (.257 ) 53% FP 36 Gas EZ-GAS 21 MBH 3/8 83% J (.277 ) 67% FP 36 DV EZ-GAS 175 MBH DV 5/16 37% B (.238 ) 32% FP 36 DV EZ-GAS 189 MBH DV Q (.332 ) 43% F (.257 ) 42% FP 36 DV EZ-GAS 21 MBH DV 3/8 75% J (.277 ) 85% FP 48 Gas 21 Gas 259 MBH 3.3 WC 4% 3.5 WC 4% FP 48 Gas 21 Gas 28 MBH 3.7 WC 5% Let WC 5% FP 48 Gas 21 Gas 3 MBH 3.2 WC 75% Let WC 75% A) 3 ½ Water Column Manifold Pressure FP 18, 24, 36 B) 4 long orificed nipple used, orifice toward gas valve DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

15 DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Pump or Flange Control Nozzle Size Air Band/ Manifold Insertion Burner Model Head Bar Pre/Post Purge Air Boot Pressure depth FP 18 Oil EZ-1 PRO 622 1/1.55 X 45 o B (psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.65 X 45 o B.65.6/.65 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.75 X 45 o B (psig) 3. to flange FP 18 DV EZ-1 PRO /12.55 X 45 o B.45.6/.65 15(psig) 3. to flange FP 18 DV EZ-1 PRO /12.65 X 45 o B (psig) 3. to flange FP 18 DV EZ-1 PRO /12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.75 X 45 o B (psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.85 X 45 o B.85.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B / (psig) 3. to flange FP 24 DV EZ-1 PRO /12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 DV EZ-1 PRO /12.85 X 45 o B / (psig) 3. to flange FP 24 DV EZ-1 PRO / X 45 o B / (psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1. X 45 o B / 1. 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B / (psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/ X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO /12 1. X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO / X 45 o B / (psig) 3. to flange FP 36 DV EZ-1 PRO / X 45 o B (psig) 3. to flange FP 48 OIL EZ /3 1.5 x 3ºB 8% (psig) 3. to flange FP 48 OIL EZ / x 3ºB % (psig) 3. to flange A) All B oil burner nozzles listed above for EZ Oil burner are Hago or Delavan B) Air tubes for FP 18,24,36 burners are 7 in length C) Air Tube for FP48 Burner is 11 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA (215) Fax: (215)

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils OIL-FIRED Series Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Standard Equipment: Cast Iron Sections - Factory Tested and

More information

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3 OIL-FIRED Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Rear or Top Flue Convertibility Standard Equipment: Cast Iron - Factory

More information

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 OIL-FIRED CAST IRON HOT WATER BOILER Parts and Optional Accessories Ordering Instructions Order Parts through your

More information

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 OIL-FIRED CAST IRON HOT WATER BOILER Parts and Optional Accessories EMPIRE II SERIES 3 Ordering Instructions Order Parts through your

More information

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 19A. mith PRESSURIZED WET BASE SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09] High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS P/N# 240007518, Rev. C [01/09] JACKET 3 5 8 10 7 9 4 6 1 11 Key Description 4 section 5 section 6 section 7 section Complete Jacket

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil EC/ECT Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION CLEARANCE.............1 B. SPECIAL ATTENTION BOXES............1

More information

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WBV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual TABLE

More information

Replacement parts EG/PEG

Replacement parts EG/PEG Replacement parts EG/PEG Table 13 EG/PEG replacement parts A B Left hand end section with heater opening (Pattern No. 1814) Left end section without heater opening(pattern No. 1813) Right hand end section

More information

G615/11 Cast Iron Boiler

G615/11 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G615-11 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

G315/6 Cast Iron Boiler

G315/6 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

G315/5 Cast Iron Boiler

G315/5 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil WBV/WV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that certain firing rates of this product meet the ENERGY STAR guidelines for energy efficiency. Installation, Operation

More information

G515/7 Cast Iron Boiler

G515/7 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview Engineering Specifications There shall be provided and installed G515-7 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing with

More information

SLANT/FIN BOILERS TRADE PRICE BOOK

SLANT/FIN BOILERS TRADE PRICE BOOK SLANT/FIN BOILERS Residential Gas, Oil, Electric & High Efficiency Commercial Gas & Oil Commercial High Efficiency TRADE PRICE BOOK EFFECTIVE: April 15, 2019 price books intended for wholesaler use only.

More information

WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WBV/WV Boilers Plastic Jacket As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance

More information

Beckett Oil Burner Parts

Beckett Oil Burner Parts 28/07/17 A110 Beckett Oil Burner Parts Oil Primary Controls - Interrupted Ignition Electronic Igniters With Baseplate Communications port enables the control to communicate with service instruments, security

More information

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WBV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual TABLE

More information

EUTECTIC EC-10 INSTALLATION AND OPERATING INSTRUCTIONS SERVICE COMPANY OIL-FIRED WATER BOILERS/NO. 2 OIL. Name Address. Telephone Model # Serial #

EUTECTIC EC-10 INSTALLATION AND OPERATING INSTRUCTIONS SERVICE COMPANY OIL-FIRED WATER BOILERS/NO. 2 OIL. Name Address. Telephone Model # Serial # EUTECTIC EC-10 OIL-FIRED WATER BOILERS/NO. 2 OIL INSTALLATION AND OPERATING INSTRUCTIONS SAFETY WARNING: KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM- MABLE VAPORS

More information

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS EXCELSIOR Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS Ordering Instructions

More information

About Carlin. Visit our website, or call us at to learn more about this authentic Made-in-America company.

About Carlin. Visit our website,  or call us at to learn more about this authentic Made-in-America company. B U R N E R S I G N I T O R S C O N T R O L S www.carlincom About Carlin Since its founding in 1949, Carlin Combustion Technology, Inc. has been a consistent leader in the heating industry. Producing oil

More information

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil WV-DV Boilers Installation, Operation & Maintenance Manual NOTICE Sidewall Venting The Peerless WV-DV is designed and built to be vented through a side wall of a building using a stainless steel

More information

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Fall Heating Specials SEPT - DEC 2017 Consistent Competitive Pricing on Heating Parts (800) 992-3682 Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

More information

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 TRIFIRE SERIES II High Efficiency Oil Fired Hot Water Boiler Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 REPAIR PARTS & OPTIONAL KITS Ordering

More information

PEERLESS BOILER PRODUCT REVIEW

PEERLESS BOILER PRODUCT REVIEW PEERLESS Series MI/MIH II/ MI 85 PC-160 Combi Cast 92 PureFire Series PSC II Series DE Series 63 & 64 Series GM Peerless Partner PEERLESS Series WB90 Series WBV Premium Jacket Series WBV Classic Jacket

More information

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON Mills 00A mith Mills 00A Smith CAST IRON OIL, GAS OR COMBITION GAS/OIL COMMERCIAL BOILER/BURNER 00AR STEAM GAUGE OPERATING CONTROL MODULATING CONTROL HI LIMIT PRESSURE CONTROL 0" STEAM DRUM TEST COCK /"

More information

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75

More information

Unmatched high efficiency product selection

Unmatched high efficiency product selection Full Line Catalog Unmatched high efficiency product selection Weil-McLain has a full product line to satisfy every application need. Evergreen: Premium Stainless Steel Award-winning stainless steel with

More information

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters High to Mid-Efficiency Residential & Commercial Heating Solutions Innovative. Efficient. Dependable. Dunkirk. Boilers and Indirect Water Heaters Helix VLT Series Gas-Fired Condensing Boiler UP TO 95 %

More information

OIL-FIRED CENTRAL FURNACE

OIL-FIRED CENTRAL FURNACE OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: CSHB60-90XE CSHB60-90XP c WARNING: Do NOT store or use gasoline or other flammable vapors and

More information

Price - $ /12

Price - $ /12 INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V8H SERIES OIL - FIRED BOILER As an ENERGY STAR Partner, U.S. Boiler Company has determined that the V8H3S, V8H3W, V8H4S, V8H4W, V8H5S, V8H5W, V8H6S,

More information

INSTALLATION, OPERATING and SERVICE MANUAL

INSTALLATION, OPERATING and SERVICE MANUAL INSTALLATION, OPERATING and SERVICE MANUAL THE INSTALLATION OF THE UNIT SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. OIL-FIRED BOILER MODEL: NBR-200 NBR-2002 HEAD

More information

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON Mills 300A mith Mills 300A Smith CAST IRON 300A3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER COMBUSTION CHAMBER DETAILS SIDE VIEW GAS FIRED FRONT VIEW WATER SIDE VIEW NATURAL DRAFT WATER

More information

Keeping Families Comfortable For More Than 60 Years

Keeping Families Comfortable For More Than 60 Years Oil Furnaces Keeping Families Comfortable For More Than 60 Years Reliable, Efficient Home Oil Furnaces Variable Speed Technology 87.5% Efficiency Optional Cooling 5 Tons Proudly Built in the USA Olsen

More information

Indiana WX Oil Furnace Inspection Guide

Indiana WX Oil Furnace Inspection Guide Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:

More information

Keeping Families Comfortable For More Than 60 Years

Keeping Families Comfortable For More Than 60 Years Oil Furnaces Keeping Families Comfortable For More Than 60 Years Reliable, Efficient Home Oil Furnaces Variable Speed Technology 87.5% Efficiency Optional Cooling 5 Tons Olsen Provides The Best Value In

More information

MAX. Installation, Operation and Maintenance Instructions. Residential Oil-Fired Boiler

MAX. Installation, Operation and Maintenance Instructions. Residential Oil-Fired Boiler Installation, Operation and Maintenance Instructions Document 1106C Installation, Operation and Maintenance Instructions for MAX Residential Oil-Fired Boiler Models (D) MAX 75 (D) MAX 100 (D) MAX 120 (D)

More information

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING PREMIUM OIL Furnaces LOWBOY SERIES UNIVERSAL SERIES FEATURING Variable Speed Option 87.5% Efficiency Optional Cooling High-Grade Stainless Steel Heat Exchanger olsenhvac.com Proudly Built in the USA PN

More information

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Series 8H. Cast Iron Gas Fired Commercial Water Boiler Series 8H Cast Iron Gas Fired Commercial Water Boiler to 0 MBH Input Over 8% Efficient 0 or 0 PSI Cast Iron Sectional Design Atmospheric Vent Modular/Multiple Boiler Configurations Available Series 8H

More information

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Description Model Weil-McLain part number. Vent Termination Kit for 3 Stainless Steel All Replacement parts Figure 96 Miscellaneous parts Description Model Weil-McLain part number Vent Termination Kit for 3" PVC All 383-500-397 Vent Termination Kit for 3" Stainless Steel All 382-200-430 Vent

More information

DOMESTIC WATER HEATER OIL FIRED

DOMESTIC WATER HEATER OIL FIRED DOMESTIC WATER HEATER OIL FIRED Models : CMO32-II CMO32-II-R CMO50-II CMO32-II & CMO32-II-R INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

WARNING. Keep area around vent terminal free of snow, ice, and debris.

WARNING. Keep area around vent terminal free of snow, ice, and debris. Information contained in this manual pertains to direct vent boilers equipped with manufacturer installed blocked vent safety control system (pressure switch).! WARNING Installations of venting shall be

More information

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS s superior ability to absorb and transfer heat makes it the ideal choice for comfortable and efficient heating systems. Since 11 Bradford White Corporation has been dedicated to building the highest quality,

More information

XL-2000 INSTALLATION AND OPERATING INSTRUCTIONS OIL-FIRED WATER BOILERS/NO. 2 OIL SERVICE COMPANY. Name Address. Telephone Model # Serial #

XL-2000 INSTALLATION AND OPERATING INSTRUCTIONS OIL-FIRED WATER BOILERS/NO. 2 OIL SERVICE COMPANY. Name Address. Telephone Model # Serial # XL-2000 OIL-FIRED WATER BOILERS/NO. 2 OIL INSTALLATION AND OPERATING INSTRUCTIONS SAFETY WARNING: KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM- MABLE VAPORS AND

More information

RETROFIT APPLICATIONS ONLY

RETROFIT APPLICATIONS ONLY Installation & Operating Manual Single stage operation oil burners RETROFIT APPLICATIONS ONLY If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow the

More information

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Models BC3095 BC4100 BC4115 BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Maximum Allowable Working Pressure 30 psi. Manufactured by: ECR

More information

99FRD 102CRD EZ-66. Instruction Manual. Advanced Oil Burners. 0.5 to 4.5 GPH. Contents. Ratings

99FRD 102CRD EZ-66. Instruction Manual. Advanced Oil Burners. 0.5 to 4.5 GPH. Contents. Ratings Models 99FRD 102CRD EZ-66 Advanced Oil Burners 0.5 to 4.5 GPH Instruction Manual Ratings Input: Fuels: Fuel unit: Electrical: Ignition: Control: Agencies: 99FRD, EZ-66...0.50 to 3.00 GPH 102CRD (2 5 /8"

More information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS Price - $3.00 As an ENERGY STAR Partner, Burnham Corporation has determined that the V73WR

More information

AFII. FII Oil. Instruction Manual MODEL. Burner. AFII 85, AFII 100, AFII 150 Types HLX & FBX air tube combinations Voltage: 120 Vac / 60 Hz

AFII. FII Oil. Instruction Manual MODEL. Burner. AFII 85, AFII 100, AFII 150 Types HLX & FBX air tube combinations Voltage: 120 Vac / 60 Hz MODEL A FII Oil Burner Instruction Manual AFII AFII 85, AFII 100, AFII 150 Types HLX & FBX air tube combinations Voltage: 120 Vac / 60 Hz AFII burner with type HLX air tube Type FBX air tube combinations

More information

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers BUDERUS BUDERUS G1 1 1 G1 G1 G1Boilers Cast Iron Commercial High Efficiency Combustion Efficiencies Up to 88.2% 0 to,982 MBH Output Thermostream Design Eliminates Thermal Shock Superior Equipment by Design

More information

Product Catalog Burners Ignitors Controls

Product Catalog Burners Ignitors Controls Product Catalog Burners Ignitors Controls About Carlin Since its inception in 1949, Carlin Combustion Technology, Inc. has been a consistent leader in the heating industry. Producing oil and gas residential

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

Instruction manual. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Ph Fx

Instruction manual. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Ph Fx Instruction manual Except where specifically stated otherwise, this manual must be used only by a qualified service technician. In the state of Massachusetts, this product must be installed by a licensed

More information

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED Models: CMO32 CMO50 DNS-1102 Rev. A DNS-0413 Rev. A CMO32 CMO50 INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF

More information

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual KLF-100 85% + EFFICIENCY OIL FIRED LOWBOY FURNACE INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual

More information

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual Series Oil, Gas & LC Gas/Oil Boilers Water Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL A. INSTRUCTION MANUALS............... B. SPECIAL ATTENTION

More information

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility Gas-fired water boilers Featuring Flexibility Boiler Manual This manual must only be used by a qualified heating installer/service technician. Read all instructions, including this manual and all other

More information

SCS SCS

SCS SCS Models: SCS-5-08-3 SCS-5-20-3 Manufactured by: DNS-0474 Rev A UTC Canada Corporation Division ICP 3400, Industrial Boulevard Sherbrooke, Quebec J1L 1V8 SEALED COMBUSTION SYSTEM OIL FIRED Save these instructions

More information

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE: www.weil-mclain.com COMMERCIAL GAS OILER Series Gas Water or Steam MH: 400-,860 Efficiency 85.% Net Load Range: Hot Water 80-, MH / Steam 975-7,40 Sq. Ft. COMMERCIAL GAS OILER APPLICATIONS INCLUDE: Apartment

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE

More information

TC II. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual

TC II. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual Series Oil, Gas & TC II Gas/Oil Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. MANUAL ORGANIZATION..............1 B. SPECIAL ATTENTION BOXES............1

More information

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave! Fall Heating Specials AUG - DEC 2016 Consistent Competitive Pricing on Heating Parts (800) 992-3682 Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

More information

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES. VICTORYII Cast-iron, power vent gas boiler VHS SERIES are available in a sealed combustion model VSPH VICTORY BOILERS AN IDEAL REPLACEMENT BOILER FOR OLDER HOMES. A PERFECT BOILER FOR NEW CONSTRUCTION.

More information

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual 342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction

More information

Peerless Boilers. Series MI. Residential Gas Boilers

Peerless Boilers. Series MI. Residential Gas Boilers Peerless Boilers Series MI Residential Gas Boilers Hard work and dedication by skilled employees have made us one of today s top cast iron boiler manufacturers. From the beginning, our main priority has

More information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER As an ENERGY STAR Partner, New Yorker Boiler Co., Inc. has determined that the CL3-091, CL3-105, CL4-126 and CL5-168

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MODEL NUMBERS: KSB0365, KSB3100, KSB4125, KSB4150, KSB5175, KSB5200, KSB6225, KSB7275 PENNCO BOILERS 85 Middle Rd. Dunkirk, NY 14048 Ph: (716) 366-5500 Fax:

More information

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable LOW --- BOY OIL FURNACE INPUT CAPACITIES: 77,000 THRU 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10232 The models OBL and OVL combine high efficiency and quiet operation with oil heating

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

G215 G315 Cast Iron Residential Boilers

G215 G315 Cast Iron Residential Boilers G215 G315 Cast Iron Residential Boilers Design Advantage Superior Heating Ø High Efficiency - AFUEs Above 86% Thermostream Design Eliminates Thermal Shock Flexible, Corrosion Resistant GL-180M Cast Iron

More information

INSTALLATION, OPERATING and SERVICE MANUAL

INSTALLATION, OPERATING and SERVICE MANUAL INSTALLATION, OPERATING and SERVICE MANUAL THE INSTALLATION OF THE UNIT SHALL BE IN ACCORDANCE WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. OIL-FIRED HI-BOY HEAVY DUTY FURNACES MODELS:

More information

Instruction manual. Ratings. Contents. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Phone Fax

Instruction manual. Ratings. Contents. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Phone Fax Instruction manual Ratings Input: EZ-1, EZ-1-HP...0.50 to 1.65 GPH EZ-2, EZ-2-HP... 1.50 to 2.25 GPH EZ-3, EZ-3-HP... 2.00 to 2.60 GPH Fuels: No. 1 or No. 2 heating oil (ASTM D396) Fuel unit: Suntec EZ-1,-2

More information

oil furnaces BCL, BFL, BML, BMLV 60, ,000 BTU HML, HMLV, HTL, HTLV 60, ,000 BTU Multiposition WML, WMLV, MPL 60, ,000 BTU

oil furnaces BCL, BFL, BML, BMLV 60, ,000 BTU HML, HMLV, HTL, HTLV 60, ,000 BTU Multiposition WML, WMLV, MPL 60, ,000 BTU oil furnaces Lowboy BCL, BFL, BML, BMLV 60,000 224,000 BTU Highboy HML, HMLV, HTL, HTLV 60,000 140,000 BTU Multiposition WML, WMLV, MPL 60,000 123,000 BTU keeping families warm for more than 60 years Higher

More information

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual KLR / KLF series 85% + EFFICIENCY OIL FIRED LOWBOY FURNACE KLR-100 KLR-200 KLF-200 KLR-100 Illustration KLF-200 INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL

More information

PROFIRE -E SERIES BURNERS

PROFIRE -E SERIES BURNERS PROFIRE -E SERIES BURNERS 8.4-42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements Integration Starts with the Burner Suitable for firetube, firebox and watertube

More information

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER Information contained in this manual pertains to direct vent boilers equipped with manufacturer installed

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

BOCK RESIDENTIAL OIL-FIRED WATER HEATERS

BOCK RESIDENTIAL OIL-FIRED WATER HEATERS TO THE INSTALLER: Please attach these instructions next to the water heater. TO THE CONSUMER: Read these and all component instructions. Please keep for future reference. Please remember to return the

More information

STARFIRE IV WATER OIL FIRED CAST IRON BOILER

STARFIRE IV WATER OIL FIRED CAST IRON BOILER Models SFH-305 SFH-300 SFH-400 SFH-45 SFH-445 SFH-560 SFH-55 SFH-675 SFH-60 STARFIRE IV WATER OIL FIRED CAST IRON BOILER PARTS AND OPTIONAL ACCESSORIES Ordering Instructions: Order Parts through your nearest

More information

QHT Manual for: SU-2A Gas Burner

QHT Manual for: SU-2A Gas Burner 1 QHT Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS. Warning: If the following instructions are not followed exactly, a fire or explosion

More information

SB615/310 Stainless Steel Condensing Boiler

SB615/310 Stainless Steel Condensing Boiler Stainless Steel Condensing Boiler Engineering Submittal Sheet Boiler Components R Engineering Specifications The boiler(s) shall have a full three pass fire tube design to allow complete combustion of

More information

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler VICTORYVSPH VICTORY VSPH Cast-iron sealed combustion, direct vent gas boiler Cast-iron sealed combustion, direct vent gas boiler THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION, RELIABILITY AND ECONOMY.

More information

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section SPECIFICATION SHEETS Steam Sample Specification Water Sample Specification MOHICAN SPECIFICATION SHEET The following sample specifications are provided by Superior Boiler Works to assist you in providing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PRODUCT LITERATURE Lennox Industries Inc. Dallas, Texas INSTALLATION INSTRUCTIONS COWB3 OIL FIRED BOILER RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE These instructions must be affixed on or adjacent

More information

Keeping Families Comfortable For More Than 60 Years

Keeping Families Comfortable For More Than 60 Years Oil Furnaces Keeping Families Comfortable For More Than 60 Years Reliable, Efficient Home Oil Furnaces Variable Speed Technology 87.2% Efficiency Optional Cooling 5 Tons PN 240011832 Rev. 2/12/19 Olsen

More information

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON mith Mills Mills 00A OIL OR GAS CAST IRON BOILER/BURNER Smith CAST IRON 00A- - Gas I=B=R Ratings: Gross Output 7,19 to 1, FRONT VIEW WITH INDUS COMB BURNER SIDE VIEW WITH INDUS COMB BURNER SIDE VIEW -

More information

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS MPO IQ 87% AFUE Oil-Fired, High Efficiency, 3-Pass Water Boiler control system Features Burnham IQ Control System True Plug & Play Controls Utilizing Burnham IQ Option Cards; Outdoor Reset (with Domestic

More information