ASPEN CANADA. Available From:

Size: px
Start display at page:

Download "ASPEN CANADA. Available From:"

Transcription

1 Available From: ASPEN CANADA Aspen Canada 7 Meridene Cr, London, ON NX M Tel:..8 Fax: matthew@aspencanada.com

2 Back of Minisplit. Front of Minisplit. Back of Minisplit. Aspen Pump Kits - Five Pump Styles. Mini Aqua. Mini Blanc. Mini / Maxi Orange. Mini / Maxi Lime. Peristaltic ASPEN CANADA Pump Selector UNIVERSAL PERISTALTIC MECHANICAL MK STANDARD COMPRESSOR SENSOR HI-FLOW.L HI-FLOW L HI-FLOW L HI-LIFT L TANK HI-LIFT L HEAVY DUTY m HEAVY DUTY m HOT WATER ECONOMY HOT WATER HEAVY MINI LIME MAXI LIME MINI ORANGE MINI MAXI ORANGE MINI BLANC MINI AQUA LOW PROFILE ERRP SUPERMARKET MACERATOR L COLD CABINET ERRP MACERATOR L CASSETTE WALL MOUNT SYSTEM TYPE DUCTED UNDER CEILING DE-HUMIDIFIER DAIRY CASE FLOOR TYPE CHILLERS MAX FLOW IN (L/HR) DUTY MAX HEAD (M) LIFT (M) TRUNKING MOUNTING IN UNIT REMOTELY BELOW UNIT BTU S (KW) of Cooling =.l to.7l per hour of condensate. Dependant on relative humidity Example:, BTU ( ton) of cooling =. to.7l per hour of condensate.

3 AQUA Mini Pump Kits Mini - No Suction Lift NO GREATER THAN 8m HEAD Mini - Constant m Suction Lift NO GREATER THAN 8m HEAD FALSE CEILING EVAPORATOR COIL CONDENSATE DRAIN TRAY A B A B EXAMPLE POSITIONS INSIDE EVAPORATOR INSIDE LINESET COVER VINYL TUBE LINESET COVER Mini Kit Includes: Duty Cycle: Capacity: Maximum Head: Suction Lift: Sound Level: Pump Dimensions: 7 Cross Section Actual Size

4 BLANC Mini Pump Kits Mini - No Suction Lift WE RECOMMEND USING THIS PUMP FOR NO GREATER THAN m HEAD EVAPORATOR COIL Mini Kit Includes: CONDENSATE DRAIN TRAY Duty Cycle: Capacity: Maximum Head: Sound Level: Pump Dimensions:

5 Mini - No Suction Lift Mini - Constant Suction Lift ORANGE Mini & Maxi Pump Kits FLOW IN LITRES/HOUR NO GREATER THAN m HEAD (WITH m SUCTION LIFT) Maxi - No Suction Lift WE RECOMMEND USING THIS PUMP FOR NO GREATER THAN m HEAD (WITH m SUCTION LIFT) FLOW IN LITRES/HOUR NO GREATER THAN m HEAD (WITH m SUCTION LIFT) Maxi - Constant Suction Lift WE RECOMMEND USING THIS PUMP FOR NO GREATER THAN m HEAD (WITH m SUCTION LIFT) Kit Includes: EVAPORATOR COIL FALSE CEILING C B A B C EXAMPLE POSITIONS A ABOVE CEILING INSIDE LINESET COVER BEHIND EVAPORATOR LINESET COVER Duty Cycle: Mini Maxi CONDENSATE DRAIN TRAY VINYL TUBE Capacity: Mini Maxi Maximum Head: Mini Maxi 7 Suction Lift: Sound Level: Mini Maxi Pump Dimensions:

6 LIME Mini & Maxi Pump Kits Mini Maxi NO GREATER THAN m HEAD NO GREATER THAN m HEAD EVAPORATOR COIL CONDENSATE DRAIN TRAY Kit Includes: OEM Kit (no ducting) Includes: Duty Cycle: Capacity: 7 Maximum Head: Sound Level: 8 Pump Dimensions:

7 Peristaltic Mini & Maxi Pump Kits FLOW IN LITRES/HOUR Mechanical FLOW IN LITRES/HOUR Standard FALSE CEILING EVAPORATOR COIL CONDENSATE DRAIN TRAY Universal Kit Includes: Mechanical Kit Includes: Duty Cycle: Capacity: 7 Maximum Head: Maximum Water Temp: Suction Lift: Sound Level: Pump Dimensions:

8 Situation: Correct: INTAKE HOSE INTAKE HOSE INTAKE HOSE INTAKE HOSE - drain pan fills with condensate - condensate flows into reservoir - intake hose between reservoir and pump empty - condensate level raises float, activates pump - pump self primes, sucks water up from reservoir (in this period pump operates dry and will click loudly) - intake hose purged of air - water enters pump and cools and lubricates - pump runs at low hum - water flows through pump and out discharge hose - water has been discharged from step - air gap equalizes atmospheric pressure - siphoning effect cannot occur - intake hose remains filled with water - drain pan fills up with condensate - intake hose already filled with water - pump immediately cooled and lubricated - pump runs quite immediately - no clicking noise occurs - The pump is operating within the proper parameters and there is no danger of overheating. (note: this is only for instances where the drain hose runs below the drain pan in the evaporator) Incorrect: INTAKE HOSE - water has been discharged from step - weight of the water in discharge hose plus atmospheric pressure at drain pan outlet forces water remaining in the intake hose to flow out through pump - intake is once again full of air INTAKE HOSE - we begin back at step - drain pan fills with condensate - condensate flows into reservoir - intake hose between reservoir and pump empty the cycle will keep repeating itself and eventually destroy the pump - The problem with this situation is every time the pump has to prime itself and purge the air from the intake hose (runs dry- see step ) it sustains a small amount of damage which wears out the pump. - Each time the pump runs dry it takes longer for it to suction the water to cool itself and eliminate the loud clicking noise. - This will destroy the pump! See steps & for proper installation. Guidelines for proper discharge: In order to fully understand the operation of these pumps it is necessary to understand some of their basic principles of operation: All Aspen mini pumps share common characteristics: - They are self priming - They are water cooled - They are water lubricated This means that when they are activated, they will self prime, however during this initial period they will suck in air and while this is happening they will be running both hot and dry. Because of this, they will emit a clicking noise which is entirely normal during the initial start up phase only, (usually around seconds or less) and this will stop when all of the air in the pump intake has been purged and the pump becomes cooled and lubricated by the water flowing through it. If the clicking noise is heard while the pump is operating after the initial start up has been completed, this is an abnormal situation and indicates that there is a problem in that the pump is running without cooling or lubrication and is overheating. This usually occurs in a split pump because the intake hose (the / clear hose between the reservoir and the pump) has emptied itself due to a siphoning effect created by atmospheric pressure. Therefore, it is vital that the intake hose is kept full of water at all times so that no air is present for the pump to suck in when it starts operation. As long as the intake hose remains full of water, every time the pump starts up it is immediately cooled and lubricated by the water flowing through it and will operate as designed, with minimal noise. Each pump is fitted with a thermal overload protector which will deactivate it in case of overheating. However, once it cools down it will begin to operate again, and if the pump is allowed to continue to operate for a sustained period of time in this condition, it will overheat, seize up and destroy itself. In some applications, the vertical distance between the reservoir and the pump can be up to m ( feet) and obviously, the longer this distance, the longer the pump will have to operate hot and dry before it evacuates the air from the intake tube. Therefore, the longer time it will have in which to damage itself. If the discharge hose is run below the level of the drain pain in the evaporator, the weight of the water in the discharge hose, plus atmospheric pressure on the water in the drain pan will cause the water to continue flowing - even after the pump has switched itself off; until all the water in the system has evacuated itself. This is similar to the siphon effect one creates when sucking gas out of a tank in a car, i.e. once you start the initial siphoning effect by sucking on the hose the contents of the tank will continue to flow out as long as the discharge end is lower than the fluid level in the tank. The flow will continue until the tank is empty or until the end of the discharge hose is lifted up higher than the fluid in the tank. At which point the atmospheric pressure equalizes and the siphoning effect stops.

9 Mini Pumps - Technical Summary Mini pumps are not designed to run dry. They are water cooled and lubricated by the condensate flowing through them. They require a float switch to detect the presence of water in the drain pan and activate the pump only when the water is present. Mini pumps always consist of two elements:. Pump body - includes an electronic PCB and the pump motor.. Reservoir - contains the filter and the switching mechanism to activate the pump. This must always be kept level and clean for proper operation of the float switch. The filter must be cleaned regularly. Mini Pump Styles:. Split type - (Orange and Aqua series) are designed with separate pump and reservoir.. Mono bloc type - (Lime or Blanc series) are designed with both the pump and reservoir as one integral unit sharing a common body. Mini pumps have two cable connections:. Power supply cable - colour coded for different voltages. Conductors for volt pumps are white, black and green. Conductors for volt pumps are red, black and green. (V models have grey wires). Overflow switch cable - designed to break the communication wire between the condenser and the evaporator in case the water level in the reservoir rises to an unacceptable level. This cable has conductors: grey (common), purple (normally closed) and orange (normally open). This colour coding is identical for all pump models except the mini Blanc which has grey and purple only. During overflow condition, the pump will continue to operate. Connection of the overflow switch is imperative for safe operation. Correct pump wiring: Mini and Maxi models are available in several voltages. Power supply to the pump should always be connected to the incoming power terminal block on the evaporator (not a separate circuit) to ensure that the pump is powered whenever the evaporator is powered. Some building codes may require a separate circuit for a pump which will override our power wiring instructions Building codes may also require a disconnect switch for the evaporator. The pump must be connected to the load terminals to isolate both the pump and evaporator. PUMP V N L G CORRECT POWER WIRING FOR PUMP IF DISCONNECT IS REQUIRED BY LOCAL CODE EVAPORATOR V WHITE BLACK GREEN DISCONNECT DO NOT WIRE PUMP FROM INCOMING SIDE OF DISCONNECT NEUTRAL Why a breather tube is required: When the pump begins sucking water out of the reservoir, an air lock will be created - unless an air intake opening is provided on top of the reservoir. The reservoir relies on gravity, so it must always be below the drain pan. DRAIN PAN CONDENSATE INLET FILTER WIRE TO PUMP AIR INTAKE PREVENTS VACUUM BREATHER TUBE PUMP INTAKE TUBE Effect of a dirty filter: If the filter is clogged, the condensate cannot pass through to raise the float. If the float does not rise, the magnet will not activate the pump and the condensate will back up until it overflows the drain pan. DRAIN PAN LIVE GROUND CONDENSATE INLET PUMP V WIRE TO PUMP FILTER L L G EVAPORATOR V RED BLACK GREEN DISCONNECT LINE LINE DO NOT WIRE PUMP FROM INCOMING SIDE VOLTS OF DISCONNECT VOLTS GROUND BREATHER TUBE PUMP INTAKE TUBE Operating Sequence of a Mini Pump. Pump is in Standby Mode: Pump is off, float rests on bottom of reservoir, overflow switch status is normal so contacts across grey and purple wires are closed and communication wire from condenser to evaporator remains energized.. Pump Enters Operation Mode: The evaporator condenses water which flows into the drain pan and through the drain hose into the reservoir lifting the float / activating the pump. The pump empties the reservoir, lowering the float, causing the pump to switch off. (A small amount of water will remain in the reservoir) The pump returns to standby mode. Overflow switch status is normal, wires are closed and communication wire from condenser to evaporator remains energized. Cycle repeats indefinitely as long as water level remains within normal limits.. Pump Enters Alarm Mode: The pump enters operation mode. Water level continues to rise due to pump failure, blockage or an undersized pump. The water level reaches /. The overflow switch activates changing the status to abnormal. The pump continues to run but contacts across the grey and purple wire open, breaking the communication circuit to the evaporator, preventing it from producing any more condensate, and shutting down the system. When occupant notices AC is not running they will contact a service technician to investigate and service.. Pump reverts to standby mode: Once the reason for the high water level has been diagnosed and corrected, the pump reverts to standby mode. CONDENSATE INLET PURPLE PURPLE CONDENSATE INLET FILTER WIRE TO PUMP FLOAT FLOAT MAGNET MAGNET BREATHER TUBE PUMP INTAKE GRAY OVERFLOW SWITCH GRAY OVERFLOW SWITCH FILTER Note: The reservoir must always be set level to permit proper movement of magnetic float. FLOAT WIRE TO PUMP FLOAT MAGNET MAGNET WATER LEVEL / WATER LEVEL / BREATHER TUBE PUMP INTAKE FROM DRAIN PAN Peristaltic Pumps - Technical Summary Three Major benefits of a peristaltic pumps:. The ability to run wet or dry enables intermittent operation with a reservoir and float switch, or continuous with the evaporator.. The capability to pump contaminated water from an evaporator coil during condensate production.. High level of suction enables remote mounting up to feet away from the evaporator. Peristaltic pump design: Peristaltic pumps operate using a rotor wheel which is electrically turned at a slow speed and has two or more roller wheels spaced at points along its perimeter. These rollers compress a rubber tube, INLET pinching it closed at each roller location. As the rotor turns, fluid inside the tubing is forced to flow in the same direction as the rotor. Before the pinch point is released, another roller pinches the starting point, preventing any back flow of liquid. This peristaltic action produces a high level of suction, but has a limited volume. Peristaltic Styles: Mechanical - uses a float inside a reservoir which is mounted below the drain pan within the evaporator enclosure. Like a mini pumps, the reservoir requires a breather tube to prevent air lock. The pump assembly can be remotely mounted up to feet away and is connected to the reservoir with / id tubing as well as a communication cable. Condensate water entering the reservoir raises the float, sending a signal which starts the pump. The mechanical type peristaltic pump includes the added benefit of an overflow switch similar to the mini pumps, however, the pump comes with a pin plug and the cable to connect the overflow switch to the evaporator must be field supplied. Universal - For installations where a reservoir is not practical or distant remote mounting is required. This pump incorporates a twin lead sensor cable with tips, red and blue, each of which are clipped onto a refrigeration component such as the hot liquid line and the cold gas line of the refrigeration circuit. When a preset temperature differential is detected between the tips, the pump begins to operate and removes any condensate as it is produced. When the temperature differential subsides the pump switches off. This pump does not incorporate an overflow switch for the evaporator. MECHANICAL OVERFLOW Cable not provided POWER FROM DRAIN PAN UNIVERSAL BLUE (COLD) RED (WARM) POWER OUTLET

10 ...to support building services & access equipment on a flat roof

product guide The most complete range of ancillary essentials designed specifically for the HVAC/R industry

product guide The most complete range of ancillary essentials designed specifically for the HVAC/R industry EN product guide The most complete range of ancillary essentials designed specifically for the HVAC/R industry Pump range & selector 4-5 i 4 PUMPS Micro-v i 4 6-7 SILENT+ PUMPS Silent+ Mini Orange 9 Silent+

More information

EVAPORATIVE COOLER PUMPS

EVAPORATIVE COOLER PUMPS EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm

More information

Technical Specification l Peristaltic Pumps Standard Part No: FP2081/2

Technical Specification l Peristaltic Pumps Standard Part No: FP2081/2 Standard Part No: FP281/2 ASPEN-5/ 1mm 15mm 77mm 1.5kg.25ltrs/hour at m head metres discharge head Horizontal: In excess of 1m Pump rating:.2a, 2V AC Black: Switched live from signal Operates on hard-wired

More information

Refrigeration pumps FOR THE RETAIL INDUSTRY

Refrigeration pumps FOR THE RETAIL INDUSTRY Refrigeration pumps FOR THE RETAIL INDUSTRY UK MANUFACTURED CONDENSATE REMOVAL PUMPS FOR USE WITH REFRIGERATION DISPLAY UNITS HIGHLY ADVANTAGEOUS FROM A HYGIENE ASPECT QUICK AND EASY TO INSTALL EXCEPTIONALLY

More information

condensate pumps For air conditioning and refrigeration technology eckerle.com

condensate pumps For air conditioning and refrigeration technology eckerle.com condensate pumps For air conditioning and refrigeration technology eckerle.com Condensate pumps in air conditioning technology Condensation is the change of state of the physical state of matter from gas

More information

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section COMMERCIAL SERIES Commercial Series Commercial Series Power switch & Nameplate location: NAMEPLATE: Single and Dual Section Must reach over behind Front Panel to access: Single and Dual Section Commercial

More information

Condensate water pumps

Condensate water pumps Condensate water pumps Welcome! If reliability is your main concern, then you finally have the right document in your hand. Among our big range of condensate pumps you will certainly find the one matching

More information

Contour TM Screw Compressors

Contour TM Screw Compressors Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for

More information

Technical Specification l Tank Pumps Hi-flow 1L & 2L Part No: 1L FP2096 / 2L FP2122

Technical Specification l Tank Pumps Hi-flow 1L & 2L Part No: 1L FP2096 / 2L FP2122 Hi-flow 1L & 2L Part No: 1L FP296 / 2L FP2122 ASPEN-5/9 Hi-flow 1L Hi-flow 2L 14mm 235mm 14mm 1.7kg 17mm 235mm 14mm 1.75kg Pump rating:.6a, 23V AC Tank capacity: 1 litre or 2 litres Inline valve to prevent

More information

OPERATING INSTRUCTIONS AND PART MANUAL. 9 Litre MANUAL & PNEUMATIC FLUID EXTRACTOR

OPERATING INSTRUCTIONS AND PART MANUAL. 9 Litre MANUAL & PNEUMATIC FLUID EXTRACTOR OPERATING INSTRUCTIONS AND PART MANUAL 9 Litre MANUAL & PNEUMATIC FLUID EXTRACTOR CT2366 CAREFULLY READ THIS MANUAL BEFORE OPERATING THE UNIT WARNING: Please read all instructions and warnings carefully

More information

A/C-HEATER SYSTEM - MANUAL

A/C-HEATER SYSTEM - MANUAL A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,

More information

WineZone Ceiling Mount Ductless Split 15

WineZone Ceiling Mount Ductless Split 15 WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS AquaArctic Remote Water Chiller A9100080 -A TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Commercial Refrigerators & Freezers Models RR28A RR55A RF28A RF55A A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73139 Issued: 8-31-2006 IMPORTANT Only

More information

Mini Condensate Pumps

Mini Condensate Pumps Mini Condensate Pumps Sauermann SI30 & SI33 The Sauermann SI30 & SI33 pumps are specifically designed to be installed on: Wall mounted units Fan coil unit Ceiling suspended units Ducted units These pumps

More information

PANTHER. Condensate removal pump Installation and operating guide

PANTHER. Condensate removal pump Installation and operating guide PANTHER Condensate removal pump Installation and operating guide The PANTHER is a self-contained condensate removal system for use directly inside trunking and highwall-mount air conditioners.the small

More information

SI 1082 o Monobloc pump for air conditioners up to 10 kw

SI 1082 o Monobloc pump for air conditioners up to 10 kw SI 1082 o Monobloc pump for air conditioners up to 10 kw Anti-vibration mount included Integral quick / connector plug AIR CONDITIONING Maximum recommended discharge height Max flow rate 8 l/h 6 m 10 W

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

INTELLIGENT SUCTION. Upgrade-AtoB

INTELLIGENT SUCTION.  Upgrade-AtoB is a variable speed suction system, that automatically adapts to the clinic s requirements; lift a suction tip and the unit responds by increasing its speed, hang up the tip and the Turbo Smart slows down.

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start Mokon Troubleshooting Guide Model 311 Process pump will not start Process pump shuts down during operation Pump seal leak Tank overflows or will not fill on systems with autofill option (water makeup valve)

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

Gobi II. English. Condensate Pump Instruction manual Gobi II

Gobi II. English. Condensate Pump Instruction manual Gobi II Instruction manual Gobi II Gobi II Condensate Pump 004045 1 Contents Introduction 0 General information 0 Important safety notice 0 Technical data 0 Product description 04 Transport and storage 06 Commissioning

More information

condensate removal pumps

condensate removal pumps BlueDiamond Condensate Removal Pumps The small condensate pump that works and works 23 ft head 6.5 ft suction lift Fit smart, fit fast, made to last 3.7 g 23 ft head 6.5 ft suction lift All the reliability

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WWW.BREEZAIRE.COM WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Commercial Refrigerators & Freezers Models SafeTemp A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73096 Issued: 10-9-2000 Revised: 3-7-2007 IMPORTANT

More information

PDF Created with deskpdf PDF Writer - Trial ::

PDF Created with deskpdf PDF Writer - Trial :: Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Safe-T-Switch 13 EZ Trap 17 AquaGuard 20 Condensate Pans & Risers 29. Acid-Detector 40 Acid-Detector for POE 40 Oil-ID 40 Turbo-Kleen 41

Safe-T-Switch 13 EZ Trap 17 AquaGuard 20 Condensate Pans & Risers 29. Acid-Detector 40 Acid-Detector for POE 40 Oil-ID 40 Turbo-Kleen 41 Condensate Covers Lineset Caps Misc. Condensate Condensate Aspen Pumps 4 Mighty Bracket 11 Drain Hose 12 Safe-T-Switch 13 EZ Trap 17 AquaGuard 20 Condensate Pans & Risers 29 Drain Line Cleaners 35 Mighty

More information

Series 6, Vertical Floor-Mount Units

Series 6, Vertical Floor-Mount Units MISSION CRITICAL Air Conditioning Systems Series 6, Vertical Floor-Mount Units Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02 Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE

More information

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

FLAKER/DCM SEQUENCE OF OPERATION

FLAKER/DCM SEQUENCE OF OPERATION FLAKER/DCM SEQUENCE OF OPERATION H O S H I Z A K I A M E R I C A The Flaker and DCM series of ice machines use a completely different ice making process than the cuber style of icemaker. The Flaker has

More information

USERS INFORMATION MANUAL

USERS INFORMATION MANUAL MODULAR DX OR CHILLED WATER COOLING WITH ELECTRIC OR HOT WATER HEATING MODELS: US, UM SERIES USERS INFORMATION MANUAL For Installation In: 1. Modular Homes & Buildings 2. Residential Homes LIST OF SECTIONS

More information

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...

More information

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N PROAIR Air Conditioner CR43 Model INSTRUCTION MANUAL Rev. H P/N 10-1008-130 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Evaporators. Direct Expansion Flooded Recirculated Over Feed Evaporators Purpose: Liquid Refrigerant is Boiled from a Low Pressure Liquid to a Low Pressure Gas by Absorbing Heat from the Medium that is being Cooled Types: Direct Expansion Flooded Recirculated Over

More information

Installation Manual BCS 1000/1500

Installation Manual BCS 1000/1500 Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120V 15A

More information

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22 Table of contents Table of contents 1 Thank you 2 Energy saving tips 2 Notes 2 Specifications 3 Safety precautions 3 Parts 5 Front view 5 Rear view 5 Accessories 6 Installation 7 Installing the exhaust

More information

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter

More information

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Remote Water Chiller, 8 GPH A9100080-A / A9100080-A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360 Technical Assistance Fax: 1.626.855.4894 NOTES TO INSTALLER: 1. Please leave this

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions PHOENIX 200 MAX LOW GRAIN REFRIGERANT HIGH CAPACITY DEHUMIDIFIER Table of Contents Therma-Stor Products Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Phoenix 200 Max Operation

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Air Conditioning Operation and Troubleshooting Matt Dunham

Air Conditioning Operation and Troubleshooting Matt Dunham Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering

More information

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners Operation Manual PortaPac 5-, 8 and 10-ton Portable Air Conditioners A AirPac, Incorporated AirPac Technology Park 888 Shenandoah Shores Road Front Royal, Virginia 22630 U.S.A. Toll Free 888-324-7722 Web:

More information

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment. Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 7 Class 7: Refrigeration Fundamentals The Vapor-compression cycle

More information

Series 6, Vertical Floor-Mount Units

Series 6, Vertical Floor-Mount Units MISSION CRITICAL Air Conditioning Systems Series 6, Vertical Floor-Mount Units Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

The Design Flaw in HVAC

The Design Flaw in HVAC The Design Flaw in HVAC www.powertronglobal.com The Design Flaw in HVAC You may know that HVAC accounts for up to 70% of a total power bill for any building. What you may not know is there is a design

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

RMF SYSTEMS PURE POWER

RMF SYSTEMS PURE POWER RMF SYSTEMS PURE POWER VACUUM DEHYDRATION UNITS Vacuum Dehydration Units THE RMF VACUUM DEHYDRATION UNITS ARE DESIGNATED OIL PURIFICATION UNITS WHICH CAN BE APPLIED DIRECTLY TO VARIOUS TYPES OF MACHINE

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

Models Series Series

Models Series Series Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Mode Temp Room Air Conditioner Service and Parts Manual 0F Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power CP10 CP12 CP10 - CP12 (06/14) 93011402_04 CONTENTS 1. PREFACE 1.1 SAFETY

More information

Models Series Series

Models Series Series Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload

More information

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz Greenleaf 100 Macerator Toilet Pump System Grey Water Capable Introduction The Greenleaf 100 toilet

More information

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the control sequence for an air-conditioning system. Explain the function

More information

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the control sequence for an air-conditioning system. Explain the function

More information

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial Product Catalog Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories Wastewater Water Systems HVAC Industrial Engineered Products hat s New! Dozens of solutions for a world of applications

More information

Instructions manual DEHUMID HP50

Instructions manual DEHUMID HP50 Instructions manual DEHUMID HP50 Table of contents 1. Unpacking 3 2. Intended use 3 3. Disposal 3 4. Safety instructions 3 5. Functional principle 4 6. Automatic defrosting system 4 7. Set up and transportation

More information

Chilled Water system

Chilled Water system Chilled Water system Introduction For large installations the Condenser, Evaporator, Compressor and Expansion device can be purchased as a package unit, known as a Chiller. The usual package consists of

More information

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S Polar Air Dryer R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S PDRCF1150029 PDRCF4602000 Instructions Manual TABLE OF CONTENTS 1. Important safety notes - Please read... 1 1.1. Transportation...

More information

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING Room Air Conditioner Service & Parts Manual 2014-2015 EP08 & EP12 Chill 115 Volts-EP08 230 Volts-EP12 THE EXPERTS IN ROOM AIR CONDITIONING 93011407_00 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

Installation Manual BCS2000/3000

Installation Manual BCS2000/3000 Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

USER AND MAINTENANCE MANUAL

USER AND MAINTENANCE MANUAL FDNF96 DEHUMIDIFIER USER AND MAINTENANCE MANUAL INFORMATION FOR USERS For the purpose and effect of Directives 2002/95/CE, 2002/96/CE and 2003/108/CE, relative to the reduction of the use of hazardous

More information

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2. HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION Page 1. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model SG153BG3GC 2.2

More information

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual Instructions Manual 1. Important safety notes - Please read... 1 1.1. Transportation... 1 1.2 Positioning... 1 1.3 Installation... 1 1.4 Before operating... 1 1.5 Maintenance by an engineer... 1 1.6 Maintenance

More information

Manual. WilTec 3/1 Macerator Toilet Pump System Article 50741

Manual. WilTec 3/1 Macerator Toilet Pump System Article 50741 Manual WilTec 3/1 Macerator Toilet Pump System Article 50741 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further

More information

Service Step by Step Trouble-Shooting Check-List

Service Step by Step Trouble-Shooting Check-List WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

Prodigy Plus - D Series Cuber Technical Review

Prodigy Plus - D Series Cuber Technical Review Prodigy Plus - D Series Cuber Technical Review Water Distributor Control Panel Air Filter ice Thickness Sensor Lower Light and Switch Panel Water Pump Water Level Sensor & Guard Curtain Switch and Magnet

More information

an ISO 9001:2008 Registered Company MINI SPACE SAVER HEAT /COOL/DEFROST QUZ-A VUZ-A

an ISO 9001:2008 Registered Company MINI SPACE SAVER HEAT /COOL/DEFROST QUZ-A VUZ-A an ISO 900:2008 Registered Company MINI SPACE SAVER HEAT /COOL/DEFROST 0000-QUZ-A 0000-VUZ-A 8865 GOLL ST. - SAN ANTONIO, TX. - 78266 - ph.20-654-77 - fax 20-654-33 90000-VUZ-A REV E 3/5/4, MINI SPACE

More information

HVAC Water chiller selection and optimisation of operation

HVAC Water chiller selection and optimisation of operation HVAC Water chiller selection and optimisation of operation Introduction Water-chiller is a broad term describing an overall package that includes an electrical control panel, refrigeration plant, water

More information

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide AQUA PREMIER ELECTRONIC ELECTRIC SHOWER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration CONTENTS Section Page Section Page Introduction.......................

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION Congratulations on the purchase of your Crysalli system. The Crysalli CP-JR-SW Still Water chiller, with CR-12FC Water Filter System are a configuration designed

More information

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C)

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C) NO: 73099 ISSUED: AUG. 29, 2001 REVISED: DEC. 16, 2003 HOSHIZAKI MODULAR FLAKER MODEL F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C) SERVICE MANUAL IMPORTANT Only qualified service technicians

More information

Greenleaf 600 Macerator Toilet Waste Pump

Greenleaf 600 Macerator Toilet Waste Pump Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.

More information

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City) BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION Business Name Site physical address (Street, Suburb, City) Nature of site / business operation Electricity Supplier Power factor

More information

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1. Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration

More information

OPERATION & MAINTENANCE MANUAL TC670

OPERATION & MAINTENANCE MANUAL TC670 OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE

More information

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T50 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-203 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL an ISO 9001:2008 Registered Company 18865 GOLL ST. - SAN ANTONIO, TX. - 78266 - ph.210-654-7171 - fax 210-654-3113 MINI SPACE SAVER HEAT /COOL 01000-QUX-A 01000-VUX-A 900101-VUX-A REV C 3/5/14, MINI SPACE

More information

Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple

Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple Welcome to the Ice-O-Matic on-line training modules. Ice. Pure and Simple DIAGSING FREEZE-UP ISSUES This module will help in diagnosis of a freeze up should it occur on various models of ICE Series Cubers.

More information

A Series Inertia Compressor Applications. Application Bulletin 115

A Series Inertia Compressor Applications. Application Bulletin 115 A Series Inertia Compressor Applications Application Bulletin 115 Application Bulletin Subject: A Series Inertia Compressor Applications Number: 115 Release EN: 006X04 Date: 1/6/92 Revision EN: Z27301

More information

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL NO.: 73067 ISSUED: JUNE 23, 1998 REVISED: DEC. 15, 2003 HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt to service or maintain

More information