Single and Two-Stage Packaged Geothermal Heat Pump

Size: px
Start display at page:

Download "Single and Two-Stage Packaged Geothermal Heat Pump"

Transcription

1 Single and Two-Stage Packaged Geothermal Heat Pump Installation & Operating Instructions Models: TVA/TVT-*** Application Forced air Geo source installation Equipped for optional AUX EL strip heat (controller included) Dual Heat, LMC (load management control), etc. add option TT-INT Tested to UL Standards 1995 and CSA Standards C Phase Models Also see and use GI102 Domestic Water Heater, Desuperheater Energy Star promotes the desuperheater and it is offered as an optional item for all TTHERM GEO heat pumps. Our exclusive GEO Logic control system optimizes the operation of a desuperheater, operating the systems only when there is adequate energy available to provide heat to the domestic hot water. However, to maximize the times the desuperheater aides in providing domestic hot water, a hot water preheat tank is suggested. Note The GEO Logic control board has various required setup adjustments, see Field Setup section. TTHERM GEO heat pumps leave the factory setup to operate on an open loop. See Open Loop Solenoid section. DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN. Important information Model Number: Serial Number: Installing Contractor: 12/06/2012 GI202

2 Table of Contents Introduction 1 Safety Considerations 2 TTHERM GEO Heat Pump Configurator (GC002) 3 Mechanical Specifications 4 Electrical Data 6 Duct System and Blower 7 Duct Sizing Chart 8 Product Dimensions 9 Installation Requirements 10 Mechanical Installation Overview 11 Mechanical Installation Source Water 12 Antifreeze 15 Open Loop Solenoid 16 Converting to Right Hand Return 18 Optional Electric Strip Heat (AUX EL) 19 Desuperheater, Domestic Hot Water (SWH) 20 Condensate Drain 22 Electrical Installation 23 GEO Logic Controller 24 Add-On Option and Accessories 25 Field Setup Overview 27 Dual Fuel/Utility Control 29 Operation Indicators 30 Power On, Start Up 35 Operational Tips 37 Preventative Maintenance 40 TVT & TVA Operating Conditions Tables 41 Troubleshooting 45 Drawing GR201 p1 Water to Air Heating Mode refrigerant circuit 48 Drawing GR201 p2 Water to Air Cooling Mode refrigerant circuit 49 Drawing UAW553 Electrical Diagram 50 Warranty Information GX /06/2012 GI202

3 Introduction Geothermal heat pumps are able to heat and cool spaces with efficiencies exceeding 350% by taking advantage of solar heat stored in the earth s crust and the earth s relatively stable temperatures. In the winter time, heat is moved from the earth into the home and concentrated using a refrigeration system. Since the heat already exists in the soil, the cost of operation of the geothermal heat pump is, in effect transportation cost for the free heat. In the summer, heat is removed from the home by reversing the refrigeration process and sending heat back out into the earth. A geothermal system consists of an earth source (either open loop or earth loop heat exchanger), a geothermal heat pump containing the refrigeration system and a ductwork system for delivering the conditioned air to the individual rooms. To learn more about geothermal heating, please visit our web site at This is a prewired package system with the necessary controls for various forced air heating applications. The GEO Logic control uses a standard, multi-wire heat pump room thermostat to initiate and terminate all heat/cool functions. There are various temperature sensors, pressure sensors, water flow switch, etc. which continuously monitor the heat pump system. The interaction of these sensing components, room thermostat requests, and the various heat pump refrigeration components plus optional AUX electric element heater are all controlled by an integrated microprocessor system (GEO Logic). The various setup conditions for this microprocessor based controller determine the application and geo product series. These setups are initially programmed by the factory, but special PC software and cable are available for reprogramming as required for controller replacement and/or other options which may apply to the specific installation. See Additional Equipment Concerns, Field Setup or Programming, Operation Indicators, User Instructions, Control Sequence, and Troubleshooting sections within this manual for further details on the GEO Logic control. An optional T2-TT-INT-1 plug-in module is available to properly handle other applications with utility load control, backup furnace, backup boiler, dual fuel, etc. In addition to the compressor and AUX heater, proper operation of the forced blower and control of the external pumps are also operated with this optional module. Moving and Storage Units should be stored in original packaging in a clean dry area. Store and move units in normal upright position. Do not stack units. Transport in vertical position only. Initial Inspection Be certain to inspect all cartons and crates as units are received before signing the freight bill. Verify that all items received have no physical damage. Report any damages or shortages on the freight bill. The purchaser is responsible for filing the necessary claims with the carrier. Concealed or hidden damages not discovered until removing packaging must be reported to the carrier within 15 days of receipt. Unit Location and Mounting Locate the unit in an indoor area where the ambient temperature will remain above 45 F [8 C]. TTHERM GEO provides 3 removable panels for ease of servicing; front (2), right and left bottom. This unit is zero clearance rated; however, allow enough room to remove panels for service and maintenance. We suggest setting the unit on a sound vibration pad, see accessories price sheet, part # E Water supply should not be hard plumbed directly with copper or PVC pipe as this could transfer any vibration to living space. Consider using Hose Kit part # L3-0015B to minimize transferred vibration. Please read and understand conditions associated with proper installation, unauthorized changes, and POWER ON procedures. Warranty Statement See the last page of this manual for detailed limited warranty coverage explanation. 12/06/ GI202

4 Safety Considerations WARNING BEFORE PERFORMING SERVICE OR MAINTENANCE OPERATIONS ON A SYSTEM, TURN OFF MAIN POWER SWITCHES TO THE INDOOR UNIT. IF APPLICABLE, TURN OFF THE ACCESSORY HEATER POWER SWITCH. ELECTRICAL SHOCK COULD CAUSE PERSONAL INJURY. Installing and servicing heating and air conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair or service heating and air conditioning equipment. Untrained personnel can perform the basic maintenance functions of cleaning coils and cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating and air conditioning equipment, observe precautions in the literature, tags and labels attached to the unit and other safety precautions that may apply, such as the following safety measures: Follow all safety codes. Wear safety glasses and work gloves. Use a quenching cloth for brazing operations. Have a fire extinguisher available for all brazing operations. Warnings, Cautions, and Notes Throughout this manual there are warnings, cautions and notes containing various levels of important information. Read all of these items carefully before performing any installation, servicing or troubleshooting of the system. Warnings are for any item which MUST be followed and failure to do so could result in serious injury or even death and/or serious damage to the equipment. Cautions relate to potentially hazardous situations or important practices which if ignored could cause minor to moderate injury or cause equipment damage or performance problems. Notes are used to indicate items of high importance but are not related to a hazardous situation. 12/06/ GI202

5 TTHERM GEO Heat Pump Configurator T V T C L D X 1 - X X Model Number Digits TVT-048-1CLDX1-XX TTHERM GEO (1) Unit Style (2) C = Combo H = Hydronic S = Split V = Vertical Unit Type (3) A = Single Stage T = Two Stage Nominal Tonnage (4, 5, 6) 024 = 2-ton 036 = 3-ton 042 = 3.5-ton 048 = 4-ton 060 = 5-ton 072 = 6-ton 096 = 8-ton 120 = 10-ton 144 = 12-ton Voltage Option (7) 1 = 208/230V, 1 Ph 2 = 208/230V, 3 Ph 3 = 460/480V, 3 Ph Auxiliary kw Option* (13, 14) 05 = 4.8 kw 10 = 9.6 kw 15 = 14.4 kw 20 = 19.2 kw XX = None *Can be factory or field installed Vintage (12) 1 Miscellaneous Kits (11) A = Soft Start Kit (Installed) X = None Desuperheater Option (10) D = Desuperheater w/factory Installed Pump X = None Configuration Option (9) L = Left Return (Standard)* R = Right Return C = Split Air Coil X = N/A or No Split Air Coil *Left return can be field converted to right return Heat Exchanger Option (8) C = Copper N = Cupronickel M = Copper (Load) & Cupronickel (Source) S = Stainless (THT only) 10/12/2012 GC002

6 TVT - Mechanical Specifications R410A Two-Stage Compressor MODEL TVT-024 TVT-036 TVT-042 TVT-048 TVT-060 (2 ton) (3 ton) (3.5 ton) (4 ton) (5 ton) Coax & Piping Water Volume gal Source Temperature F (min/max) 20 / / / / /120 Nominal source differential* F (H/C) 3/12 9/11 10/11 6/11 6/10 Factory Charge R410A 2 lbs. 14 oz. 4 lbs. 8 oz. 4 lbs. 8 oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Static Pressure Nominal Static Pressure Design Air Filter 7/8 X 21 7/8 7/8 X 28 7/8 7/8 X 28 7/8 7/8 X 27 1/2 7/8 X 27 1/2 X 27 1/2 X 27 1/2 X 27 1/2 X 37 7/8 X 37 7/8 Weight Packaged (lbs) HEAT EXCHANGER PRESSURE DROP TABLE Water-to-Air (Source Side, Pure 68 F) Model GPM PSID Model GPM PSID Model GPM PSID (ref) ton (ref) ton 5-ton (ref) (ref) (ref) ton (ref) ton (ref) (ref) PRESSURE DROP MULTIPLIERS Freeze Point ( F) 20 F 25 F 30 F 35 F 40 F Pure Water Multiplier Methanol 12.5%* Multiplier Propylene Glycol 20%* Multiplier Ethanol 20%* Multiplier *By volume Feet of Head = PSI x 2.31 Model TVT-024 TVT-036 TVT-042 TVT-048 TVT-060 TVT - HEATING ISO SPECIFICATION ENERGY STAR Stage Source GPM GWHP Ground Water GLHP Ground Loop 50 F 68 F 32 F/41 F 68 F Capacity Blower Temp Capacity Blower Temp COP COP Btu/h CFM Rise Btu/h CFM Rise FL PL FL PL FL PL FL PL FL PL Model TVT-024 TVT-036 TVT-042 TVT-048 TVT-060 TVT - COOLING ISO SPECIFICATION ENERGY STAR Stage Source GPM GWHP Ground Water GLHP Ground Loop 59 F 80.6 F 77 F/68 F 80.6 F Capacity Blower Temp Capacity Blower Temp EER EER Btu/h CFM Drop Btu/h CFM Drop FL PL FL PL FL PL FL PL FL PL Capacities are based on temperatures shown in headin source is left group, return air right group. 2. Stated Btu/h is the ISO formula adjusted, actual HP supply energy delivered is 2% greater. 3. Temp rise is based on sensible only. 4. All ratings based upon operation at lower voltage of dual voltage rated models. 5. Ground Loop Heat Pump ratings based on 15% antifreeze solution. 12/06/ GI202

7 TVA Mechanical Specifications R410A Single Stage Compressor MODEL TVA-036 TVA-048 TVA-060 (3 ton) (4 ton) (5 ton) Coax & Piping Water Volume gal Source Temperature F (min/max) 20 / / /120 Nominal source differential* F (H/C) 9/11 6/11 6/10 Factory Charge R410A 4 lbs. 8 oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Static Pressure Nominal Static Pressure Design Air Filter 7/8 X 28 7/8 7/8 X 27 1/2 7/8 X 27 1/2 X 27 1/2 X 37 7/8 X 37 7/8 Weight Packaged (lbs) HEAT EXCHANGER PRESSURE DROP TABLE Water-to-Air (Source Side, Pure 68 F) Model GPM PSID Model GPM PSID Model GPM PSID (ref) ton (ref) ton 5-ton (ref) (ref) PRESSURE DROP MULTIPLIERS Freeze Point ( F) 20 F 25 F 30 F 35 F 40 F Pure Water Multiplier Methanol 12.5%* Multiplier Propylene Glycol 20%* Multiplier Ethanol 20%* Multiplier *By volume Feet of Head = PSI x 2.31 Model TVA HEATING ISO SPECIFICATION ENERGY STAR Source GPM GWHP Ground Water GLHP Ground Loop 50 F 68 F 32 F 68 F Capacity Blower Temp Capacity Blower Temp COP Btu/h CFM Rise Btu/h CFM Rise TVA TVA TVA Model TVA COOLING ISO SPECIFICATION ENERGY STAR Source GPM GWHP Ground Water GLHP Ground Loop 59 F 80.6 F 77 F 80.6 F Capacity Blower Temp Capacity Blower Temp EER EER Btu/h CFM Drop Btu/h CFM Drop TVA TVA TVA Capacities are based on temperatures shown in heading, source is left group, return air is right group. 2. Stated Btu/h is the ISO formula adjusted, actual HP supply energy delivered is 2% greater. 3. Temp rise is based on sensible only. 4. All ratings based upon operation at lower voltage of dual voltage rated models. 5. Ground Loop Heat Pump ratings based on 15% antifreeze solution. COP 12/06/ GI202

8 Model TVT - Electrical Data Single Phase Voltage Compressor Blower Desup. Pump Loop Pump (Ext) Total Min. (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. TVT / TVT / TVT / TVT / TVT / Model TVT - Electrical Data Three-Phase Voltage Compressor Blower Desup. Pump Loop Pump (Ext) (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. TVT-024 NOT AVAILABLE TVT / TVT / TVT / TVT-060 NOT AVAILABLE Total Min. Max. Fuse/ HAC R Max. Fuse/ HAC R Model TVA Electrical Data Single Phase Voltage Compressor Blower Desup. Pump Loop Pump (Ext) Total Min. (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. Max. Fuse/ HACR TVA / TVA / TVA / Model TVA Electrical Data Three-Phase Voltage Compressor Blower Desup. Pump Loop Pump (Ext) Total Min. Max. Fuse/ HACR (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. TVA / TVA / TVA / /06/ GI202

9 Duct System and Blower Metal ductwork should be used, and flexible connectors are required for supply and return air duct connections. All TVA & TVT THERM GEO units have flanges for connecting your supply plenum and return ductwork. If the duct system is installed in an uninsulated space, the metal ductwork should be insulated on the outside to prevent heat loss, absorb noise, and prevent condensation during cooling. If the TTHERM GEO is connected to existing ductwork, the ductwork must have the capacity to handle the air volume required to unload the heat pump. Undersized ductwork will cause noisy operation due to high air velocity, and poor operating efficiencies. Check the Duct Sizing Chart provided. The TTHERM GEO heat pumps use a variable speed ECM blower motor. The GEO Logic controller determines the speed of the motor based on mode and operation sequence. The blower speed can be fine-tuned to each installation with the tweak switches described below. The blower will not operate properly if ductwork is not attached. The ductwork provides static pressure to give the blower motor a load to work against. All blower compartment covers must be in place for the heat pump to operate correctly. TVT - Blower CFM Two Stage Compressor Model G Cool Y Heat Y Cool Y2 Heat Y2 Cool Y 2 Heat + W2 E TVT TVT TVT TVT TVT CFM Rounded Y2 can be field fine-tuned or tweaked with a 4 position switch. The 4 positions are 0%, -6%, +6%, +12% G can be field fine-tuned or tweaked with a 4position switch. The 4 positions are 0%, -6%, +6%, +12% See figure 8 for location of 4 position switch TVA - Blower CFM Single Stage Compressor Model G Cool Y Heat Y Cool Y Heat + W2 E TVA TVA TVA CFM Rounded Y can be field fine-tuned or tweaked with a 4 position switch. The 4 positions are 0%, -6%, +6%, +12% G can be field fine-tuned or tweaked with a 4position switch. The 4 positions are 0%, -6%, +6%, +12% See figure 8 for location of 4 position switch The Y tweak switch is the 2 nd switch below the 10 pin thermostat socket. The G tweak switch is the 3 rd switch below the 10 pin thermostat socket. Be very sure the tweak switches are set in their position indents. 12/06/ GI202

10 Duct Sizing Chart Acceptable Branch Duct Sizes Acceptable Main or Trunk Duct Sizes CFM ROUND Rectangular Round Rectangular x8, 4x x10, 5x8, 6x x10, 6/8,4x14,7x x10, 8x8, 4x x14, 8x10, 7x x20, 6x16. 9x x18, 10x10, 9x x20, 7x10, 6x12, 8x x20, 8x14, 9x12, 10x x20, 6x16, 9x10, 8x x10,6x8, 8x12, 7x x10, 7x18, 8x16, 10x x18, 9x15, 10x14, 12x x18, 12x14, 8x x20, 12x18, 14x x25, 12x20, 14x18, 15x x30, 15x18, 14x x35, 15,20, 16x19, 12x30, 14x x40, 12x30, 15x25, 18x x40, 15x25, 20x x40, 16x25, 20x20 Table calculated for 0.05 to 0.10 inches of water friction per 100 of duct. At these duct design conditions, along with the pressure drop through the filter, the total design external static is 0.20 inches of water. 12/06/ GI202

11 Product Dimensions 12/06/ GI202

12 Installation Requirements 1. All installation work must be performed by trained, qualified contractors or technicians. TTHERM GEO sponsors installation and service schools to assist the installer. Contact TTHERM GEO at for upcoming dealer training events. WARNING ALL ELECTRICAL WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND LOCAL ELECTRIC CODES, ORDINANCES, AND REGULATIONS. WARNING OBSERVE ELECTRIC POLARITY AND WIRING COLORS. FAILURE TO OBSERVE COULD CAUSE ELECTRIC SHOCK AND/OR DAMAGE TO THE EQUIPMENT. CAUTION This unit can only be used for its intended purpose as described in this manual. Any internal wiring changes, modifications to the circuit board, modifications or bypass of any controls, or installation practices not according to the details of this manual will void the product warranty, the safety certification label, and manufacturer product liability. TTHERM GEO cannot be held responsible for field modifications, incorrect installations, and conditions which may bypass or compromise the built-in safety features and controls. 2. If this is a Dual Fuel system, this product relates only to the addition to the furnace ducting system external to the gas or oil force air furnace. The owner/installer assumes all responsibility and/or liability associated with any needed installation of the gas/oil furnace, fuel system, flue, chimney, etc. Any instructions or comments made within this manual (or factory phone assistance) relating to the gas/oil furnace are provided as comments of assistance and helps only. CAUTION This unit shall not be operated (either heating section or blower) until the interior of the structure is completed and cleaned. This also means all duct work must be complete with filter, etc. Manufacturer s warranty is void if this unit is operated during structure construction. CAUTION Hazards or unsafe practices could result in property damage, product damage, severe personal injury and/or death. 3. All removed or discharged refrigerant must be recovered In accordance with local and federal statutes. Should a compressor need replacing, the compressor oil is to remain with the compressor. Refrigerant lines on the compressor must be capped during service. 4. Remember, safety is the installer s responsibility and the installer must know this product well enough to instruct the end user on its safe use. At TTHERM GEO the safety of the installer and the end user is of highest priority. Remember, safety is the installer s responsibility and the installer must know this product well enough to instruct the end user on its safe use. Professional installers should be trained and experienced in the areas of handling electrical components, sheet metal products, and material handling processes. 12/06/ GI202

13 Mechanical Installation Overview This TTHERM GEO series unit cannot correct airflow problems inherent within the duct work system. The following items should be carefully considered and properly followed for all installations: Examination of the existing forced air furnace Prior to starting this installation, examine the total furnace system and make necessary comments or recommendations to the homeowner. Remember, if a marginal condition exists within the existing duct work system, the installation of a geothermal heat pump will not cure PRE-EXISTING conditions. Consider such items as adequate cold air return and supply duct. Inspect and count supply and return registers for size and number. Heating capacity Size the geothermal heat pump according to the normal heating requirements as the building exists today. Do not necessarily match to the existing furnace nameplate because it may be oversized. The geothermal heat pump should be properly sized for the heat loss of the house. Heat loss and heat gain audits should be done to determine proper equipment sizing. Flexible duct connections Flex duct connections are required for both the supply and return duct connections and metal duct systems. Other plenum equipment Auxiliary equipment such as humidifiers, zone plenum dampers, etc., located within the plenum which may cause a non-uniform airflow issues may have to be removed if they cause to great reduction to system airflow. Comment zone dampers cause back pressure on the blower and overall reduced airflow. Reduced airflow can cause the geothermal unit to perform poorly or in some cases cause icing or freeze ups in the air coil. If the smallest zone cannot handle the minimum CFM requirements of the heat pump a dump zone and/or allow air flow to bypass to other zones. Insufficient cold air return capacity Installation experience indicates this is a major concern. In fact, it could represent a problem in as many as 60% of the installations, especially if there is a requirement to increase airflow when the existing cold air return capacity is already undersized or restricted. Check the static pressure within the return cabinet or the suction at the filter cabinet door. Do not assume because there is a register on the wall, the hole behind the register or the passageways are equal to this register. Sharp offsets and transitions in the cold air return system often cause severe restrictions. Expect to add additional registers or a relief register in the main cold air return duct. Best practice would include both high and low return registers. Closed Loop Applications Closed loop system re-circulates the same water/antifreeze solution through a closed system of underground high-density polyethylene pipe. As the solution passes Horizontal Closed Loop through the pipe it collects heat (in the heating mode) that is being transferred from the relatively warm surrounding soil through the pipe and into the relatively cold solution. The solution is circulated back to the heat pump that extracts its heat and then returns to the ground to absorb more heat from the earth. Earth loops must be sized properly for each particular geographic area and individual capacity requirements. The TTHERM GEO series heat pumps are designed to operate on either vertical Figure 1 or horizontal closed loop applications. (Figures 1 & 2) Vertical loops are typically installed with a well drilling rig up to 200 feet (61 meters) deep or more. Horizontal systems are typically installed with excavating or trenching equipment approximately six to eight feet ( meters) deep, depending on geographic location and length of pipe used. Horizontal bored loops are typically installed 15 feet deep. Vertical Closed Loop Lake or Pond Loops Closed loop systems may also be used in lakes or rivers to supply a heat source to the heat pump. Typically a loop consisting of geothermal pipe can be designed and placed in an area at least 12ft (3.7 meters) with some water currents present. In any lake or pond, municipal and local codes must be observed in regards to a lake or pond loop. The use of an environmentally friendly loop fluid like Propylene Glycol should be considered in the event damage should ever occur to the loop. Consult sales at TTHERM GEO or an IGSHPA or CGC certified installer for proper Figure 2 loop design and installation. State and local codes apply. 12/06/ GI202

14 Mechanical Installation Source Water WARNING LOOP DESIGN IS EXTREMELY IMPORTANT FOR PROPER HEAT PUMP OPERATION. INCORRECT LOOP DESIGN WILL REDUCE HEAT PUMP EFFICIENCY, CAUSE POOR PERFORMANCE OR MAY RENDER THE SYSTEM UNUSABLE. IF YOU LACK EXPERIENCE DESIGNING LOOP FIELDS, CONTACT AN IGSHPA OR CGC CERTIFIED GEOTHERMAL LOOP CONTRACTOR FOR PROPER INSTALLATIONS. Water Connections General The following pages outline typical piping arrangements for the most common source water connection options, as well as flushing and filling procedures and antifreeze requirements for closed loop systems. TTHERM GEO recommends hose kits for the source water connection points at the heat pump. This will provide a flexible connection to reduce and isolate vibrations transmitting from the compressor into other parts of the system. Hose kits also provide P/T ports for monitoring pressure and temperature (see below). Note TTHERM GEO heat pumps are factory set for open loop. J11 must be removed for proper operation on an antifreeze protected closed loop. See figure on page 26 for the location of J11. Once closed loops are completed, they must be pressure tested to at least 60 PSI to ensure integrity. Once pressure is tested, loop must be purged of all foreign debris and filled with fluid. All air must be removed at this time by flushing the system. (Page 11, Table 2) shows approximate fluid volumes. P/T Adapter Pressure/Temperature (P/T) plugs Should be installed in the adaptor elbow on the entering and leaving water line of the heat pump on a closed system. (Figure 3) A thermometer can be inserted into the P/T ports to check entering and leaving water temperatures. A pressure gauge can also be inserted into these P/T ports to determine the pressure differential between the entering and leaving water. This pressure differential can then be compared to the engineering specifications data to determine the flow rate of the system. Non Pressurized Loops require an Figure 3 air separator/stand pipe to eliminate air and to hold enough fluid to compensate for the expansion and contraction of the loop pipe and fluid. Purge and fill valves should be placed between the loop manifold valves and the insulated pump pack. A Flow Meter is an important part of the system. It provides a visual indicator of loop flow in GPM. A flow meter can be installed on either side of the pump pack, but must be installed per manufacture recommendations so it reads accurately. Non Pressurized Loops require an air separator/stand pipe to eliminate air and to hold enough fluid to compensate for the expansion and contraction of the loop pipe and fluid. Purge and fill valves should be placed between the loop manifold valves and the insulated pump pack. See figure 4. 12/06/ GI202

15 Pressurized Loops do not require an air separator. They require purge and fill ports between the loop manifold valves and the insulated pump pack. After purging a pressurized loop, it should maintain 45 to 60 psi static pressure. The Geothermal Loop Pipe stretches under pressure so may need to be pressurized above the desired pressure several times to achieve the recommended static pressure. Pressurized loops must maintain enough static pressure to compensate for the expansion and contraction of the loop pipe and fluid. Loop Pump Selection Select a loop circulation pump based upon the GPM required and total system pressure drop. See specification, page 4. Geothermal heat pump Btu/h capacity and efficiency are directly related to the GPM flow through the unit. Vibration pad We recommend setting the unit on a sound vibration pad, available from most distributors or accessories price sheet E Water quality Models with standard copper heat exchanger coils require the installer to evaluate water quality and meet minimum water properties. ph < 7.5 Calcium hardness < 100 PPM Iron fouling < 0.2 PPM (Ferrous) < 0.5 PPM of oxygen Hydrogen sulfide (H 2 S) < 0.5 PPM Chloride levels < 20 PPM Erosion/clogging < 10 PPM, particles Filter, if required < 800 micron size Softened water is recommended along with 2 oz of common house chlorine bleach for every 10 gallons of water. 12/06/ GI202

16 Figure 4 Non-Pressurized Closed Loop with Flow Center Typical piping diagram. Figure 5 Pressurized Closed Loop with Flow Center Typical piping arrangement. 12/06/ GI202

17 Antifreeze When considering the earth loop solution, water quality is very important. TTHERM GEO recommends a minimum of soft water (not well water) treated with 2 oz. of household chlorine bleach for each 10 gallons of total volume. TTHERM GEO s recommended antifreeze concentration is 22% which will yield a freeze protection of 18 F. This concentration of glycol requires additional additives to protect the system. TTHERM GEO recommends Enviro-Guard HD propylene glycol for this reason. Over antifreeze protecting a loop field decreases pumping capacity when the loop gets cold and reduces thermal transfer. Under protecting a loop field will cause the THERM GEO heat pump to take action protecting itself from damage. This action will result in a loss of geothermal capacity, and AUX heat may be required to maintain the temperature in the home. Table 2 Approximate Fluid Volume (gal) per 100ft Pipe Size Volume Pipe Size Volume ¾ IPS SDR Rubber Hose 1 IPS SDR Polyethylene 1-1/4 IPS SDR Copper 1-1/2 IPS SDR Type M 2 IPS SDR WARNING PREVENTING FREEZE-UP IS INSTALLER/USER RESPONSIBILITY. DAMAGE CAUSED BY FREEZE-UP IS NOT COVERED BY WARRANTY. CAUTION Softened water is recommended along with 2 oz of common household chlorine bleach for every 10 gallons of water. WARNING NOT ALL GLYCOLS PROVIDE THE SAME LEVEL OF CONCENTRATION. MOST GLYCOLS DO NOT CONTAIN ENOUGH INHIBITORS FOR THE RECOMMENDED CONCENTRATION LEVELS.FOR GEOTHERMAL SYSTEMS.. Open Loop An open system gets its name from the open discharge of water after it has been used by the heat pump. A well pump and well must be available that can supply all of the water requirements of the heat pump along with any other water requirements drawing off that same well. The well must be capable of supplying the heat pumps required flow rated for up to 24 hours per day for the coldest winter day. Figure 6 shows the necessary components for water piping of an open system. First a bladder type pressure tank with a draw down of at least 1-1/2 to 2 times the well pump capacity must be installed on the supply side of the heat pump to prevent short cycling the well pump. Constant pressure well pumps need to deliver the GPM flow rate of the TTHERM GEO heat pump and other possible consecutive demands. Shut off valves and boiler drains on the entering and leaving water lines are necessary for future maintenance. A screen strainer is placed on the supply line with a mesh size of 40 to 60 and enough surface area to allow for particle buildup between cleanings. Hose kits are installed between the heat pump and ridged plumbing to reduce vibration transfer. Hose kits have pressure temperature (P/T) plugs placed in the supply and discharge hydrant elbows so that 12/06/ GI202

18 thermometers or pressure gauges can be inserted into the water stream. On the well water discharge side of the heat pump a flow meter is installed to provide a visual indicator of open loop flow in GPM. The water solenoid valve must be installed to control water flow through the unit. After the water solenoid a flow control valve is installed to limit maximum flow through the heat pump. The ball valve installed in the leaving water line can be used to create a small amount of back pressure to quiet the flow control valve if needed. Discharge water temperature should not drop below 39 at any time during the units operation. Remove handle on the entering and leaving water ball valves to prevent accidental change of flow.. The solenoid valve is then wired to two leads (brown/yellow and gray) provided. This valve will open when the unit is running and close when the unit stops. The visual flow meter will allow visual inspection of the flow requirements, and can be useful in determining when maintenance is required. Schedule 40 PVC piping, copper tubing, polyethylene or rubber hose can be used for supply and discharge water lines. Make sure line sizes are large enough to supply the required flow with a reasonable pressure drop (generally 1.00 diameter). Water discharge is generally made to a drain field, stream, pond, surface discharge, tile line, or storm sewer. Solenoid Valve Wiring (for Open Loop Systems) Inside the cabinet, tie-wrapped to the OUT water pipe, are two leads (brn/yel and gray) for direct connection to a 24VAC solenoid. CAUTION Using a drain field requires soil conditions and adequate sizing to assure rapid percolation or the required flow rates will not be achieved. Consult local codes and ordinances to assure compliance. Do not discharge water to a septic system. The heat pump should never be operated with flow rates (GPM) less than specified. Discharge water should never be lower than 39 F. Operation of the unit with less than required flow rate or no flow may result in freezing water in the water to refrigerant heat exchanger. This will cause the unit to shut down on lowpressure lockout. If the unit locks out Low pressure, verify that the unit has the required flow and reset the unit by shutting off power to the unit for one minute. Do not continually reset the unit; if the unit locks out more than once call your service professional. Continued reset of the unit can freeze water inside the water coil to the point of rupturing the water coil (no warranty for freeze ruptured coils). 12/06/ GI202

19 Figure 6: Open Loop Typical piping diagram. Note TTHERM GEO heat pumps are factory set for open loop operation. Open Loop Operation TTHERM GEO heat pumps are factory set for open loop operation. Open or Closed loop operation is set with jumper J11 on the left side of the GEO Logic controller. The jumper must be in place on J11 if the unit is operated on an open loop. The GEO Logic controller protects the heat exchanger from freezing by causing the compressor to shut down when the leaving water temperature reaches 39 F. The compressor will remain off for 2 Anti-Cycle-Delay s, and the EARTH LOOP FLOW/ SOURCE WATER LIMIT & HP STAGE 1 LED s will pulse, while the water runs and warms up. The compressor will then restart again providing heat until the LWT again reaches 39 F. If this routine continues the heat pump may not be able to maintain the temperature in the house and the backup heat will come on. Possible causes would include: 1. Supply water filter that needs cleaning 2. Inadequate water supply 3. Water discharge line that is plugging up 4. Entering water temperature less than 50 degrees Water Coil Maintenance Water quality is a major concern for open systems. Problems can occur from scaling, particle buildup, suspended solids, corrosion, ph levels outside the 7-9 ranges, or biological growth. A cupronickel heat exchanger is recommended for open loop applications. If poor water quality is known to exist in your area a closed loop system may be the best alternative. Water coil cleaning on an open loop system may be necessary on a regular basis. 12/06/ GI202

20 Converting to Right Hand Return Converting to Right Hand Return One of the unique features of your TTHERM GEO series heat pump is the ability to quickly and easily convert the unit from the factory-shipped left-hand return air configuration to a configuration where return air enters the unit from the right-hand side. This is accomplished by moving the access doors and GEO Logic control box from the front of the cabinet to the rear of the cabinet and rotating the heat pump First, make certain that power is disconnected from the heat pump and remove the front, rear, and side panels opposite of the air coil and filter. 2. Disconnect the two blower motor wire harnesses at the blower motor. 3. Using a Phillips screwdriver, remove the control box and hinged access doors. The attached wiring harnesses are sufficiently long enough to allow for the relocation of the control box and door without rewiring these components. Be sure the refrigerant manifold distribution lines do not rest against the u-bends of the coil or the relocated control box. 4. Relocate and secure the control box and doors on the opposite side of the cabinet. 5. If you are not installing electric strip heat reattach the blower motor cables, front, rear and side panels. Your TTHERM GEO has now been converted to right-hand return. 6. If you are installing an optional electric strip heat module (KN-XX-T) observe the steps below. Step #1 Remove (4) blower retaining screws and the retaining bracket keeping the blower from sliding. Remove blower assembly from the cabinet. Step #2 Remove the electrical box and heating element/s from the electric heater s plenum. See Auxiliary Strip Heat Installation Instructions. Step #3 Invert the heater s electrical box and reinstall in the heater s plenum. This will keep the strip heat elements in the blower s air stream. Step #4 Install the electric strip heater to the blower with the electrical box opposite the blower motor, and secure assembly with sheet metal screws through the holes provided. Step #5 Install the electric strip heat/ blower assembly from the new back of the cabinet, securing the assembly to the cabinet with the screws removed during blower removal. Step #6 Finish the installation as described in the electric strip heat installation instructions. Step #7 Route and secure the electric strip heat low voltage control wires so they do not come in contact with the refrigerant manifold distribution line. 7. Reattach the blower motor cables, front, rear and side panels. Your TTHERM GEO has now been converted to right-hand return with electric strip heat. 12/06/ GI202

21 Optional Electric Strip Heat (AUX EL) Electric Resistance Heat (optional) TTHERM GEO series heat pumps may be ordered with optional electric resistance heat. This feature is installed for various reasons. Most commonly, particularly in northern climates where extremely low temperatures are found, geothermal heat pumps are often intentionally undersized for the coldest days of the year. In situations where the heat pump is undersized, the KN series auxiliary electric heating unit (AUX EL) can be installed in the heat pump to meet your additional heating demands during these extremely cold days. Additionally, the AUX EL feature can be utilized for emergency heat if your heat pump should malfunction for any reason. Although these units utilize 100% efficient electric energy, AUX EL can never approach the energy efficiency of your TTHERM GEO geothermal heat pump alone. For this reason, your TTHERM GEO series heat pump will attempt to utilize geothermal heating as much as possible. When heating demands reach a level where geothermal heating cannot keep up, the exclusive thermostat and the GEO Logic control will add just enough resistance heating to meet your heating demands. An optional AUX EL Strip Heat Kit can be installed in your TTHERM GEO heat pump at any time. AUX EL kits in various sizes are available from TTHERM GEO. The addition of one of these kits should only be performed by trained professionals who are familiar with this product. Not all of the AUX EL units can be paired with every TTHERM GEO heat pump. Please refer to the table below to determine which resistance heat unit can be used with your heat pump. Models Available AUX EL Models Nominal T2-KN-05-1-T T2-KN-10-1-T T2-KN-15-1-T T2-KN-20-1-T Ton 5 kw 10 kw 15 kw 20 kw TVT OK OK TVA-036/TVT OK OK OK TVT OK OK OK TVA-048/TVT OK OK OK TVA-060/TVT OK OK OK OK 12/06/ GI202

22 Desuperheater, Domestic Hot Water General TTHERM GEO series units may be equipped with a double wall desuperheater and an integrated circulating pump (can be a price deduct) that can provide Supplemental Domestic hot Water (SDW). This is done by stripping heat from the superheated gas leaving the compressor. Fuses the desuperheater pump is fed from the pump s 10-amp fuses. The fuses are located on the pump relay board in the line voltage control box. At the pump relay board top, moving the blk/red wire from the P tab to the SWH tab (or vice versa) provides a switch. General Plumbing and Installation Suggestions 1. Insulated ½ copper piping should be used from the hot water tank to the desuperheater connections on the left side of the unit. The copper tubing should be straight to maintain good water velocity and prevent air pockets from forming at the pump inlet. WARNING NEVER USE PEX TUBING WHEN CONNECTING A DESUPERHEATER TO THE DOMESTIC WATER SYSTEM. NORMAL CYCLING OF THE DESUPERHEATER PUMP CAN CAUSE THE DISCHARGE WATER TEMPERATURE TO EXCEED THE RATED TEMPERATURE OF THE PEX CAUSING THE PEX TO FAIL. THIS HAS CAUSED FLOODING IN BASEMENTS. DESUPERHEATER MUST BE PLUMBED IN COPPER. 2. Shut off valves should also be used to service the desuperheater pump without draining the entire hot water tank. Note: Always be sure these valves are open when pump is running. 3. Pump problems develop by running the pump dry or with air in the system. All air must be purged from the desuperheater plumbing before the pump is engaged. 4. To purge the air from the desuperheater lines close the ball valve between the desuperheater return, boiler drain, and the bottom port of the water heater. Open the boiler drain allowing water to flow through the complete desuperheater circuit purging out the air. When all the air is purged, close the boiler drain and open the ball valve to the bottom of the water heater. 5. Never operate the system without the high temperature switch (normally factory installed) as tank temperatures could become dangerously high. 6. Poor water quality may reduce the effectiveness of the desuperheater pump or not allow the pump to circulate. 7. Desuperheater maintenance includes periodically opening the drain on the hot water tank to remove any deposits. Hard water may cause scale buildup in the desuperheater coil reducing its effectiveness. 8. The temperature difference between the water entering and leaving the desuperheater will depend on the desuperheater entering water temperature. The desuperheater will make less hot water in cooling. 9. For the maximum efficiency from the provided desuperheater module, TTHERM GEO suggests a water heater preheat tank as shown in Figure 7. The Figure 7A single tank plumbing and application is shown for information only. There are a number of ways the desuperheater/pump can be plumbed into the building/household water heater tank. However, many common methods used are not very effective because they simply circulate already heated water from the water heater tank through the desuperheater. The heat pump desuperheater cannot effectively produce hot water energy if the temperature of the water entering the desuperheater is close to or beyond the compressor gas capability to transfer energy into this circulated water typically 110 F to 130 F. In TTHERM GEO heat pumps the desuperheater is automatically disabled when it is unable to add additional hot water energy to the water heater or preheat tank. TTHERM GEO units have the option of the desuperheater operating whenever the compressor runs or it can be disabled in cooling only by removing jumper J14 on the GEO Logic controller board. 12/06/ GI202

23 Figure 7 Desuperheater Piping, Preheat Tank This is the most effective and efficient arrangement for high hot water needs. This is also the recommended method when using a gas water heater with a desuperheater. The preheat tank need not be as big as the standard water heater; 40- gallon size can be very effective. With this two tank system the desuperheater will always act as a city/well water pre-heater and the standard water heater (electric elements or gas) only requires tempering energy which is a very small percentage of domestic water heater energy required. Figure 7 Figure 7A Desuperheater, Single Tank Concept The water flow is from the top tee, through the desuperheater, pushing the heated water into the water heater bottom. The ball valve at the water heater bottom (between drain valve and tank) is to allow shut-off and an easy method of purging the desuperheater piping with city/well water forcing through the system and out the hose bib drain. Note: Both ball valves must be open whenever the desuperheater electrical source power wire is plugged into the SWH tab at the control box, upper right, relay board. Inspect the dip tube in the water heater cold inlet for a check valve. If a check valve is present it must be removed or damage to the desuperheater circulator will occur. Before restoring electrical supply to the water heater, adjust the temperature setting on the tank. On tanks with both upper and lower elements, the lower element should be turned down to the lowest setting, approximately 100 F. The upper element should be adjusted to 120 F to 130 F. Depending upon the specific needs of the customer, you may want to adjust the upper element differently. On tanks with a single element, lower the thermostat setting to 120 F. Figure 7A CAUTION Do not run desuperheater pump without supply from water heater. This will damage the pump. 12/06/ GI202

24 Condensate Drain In the cooling season, condensation is collected in a drip pan and exits the heat pump through the labeled hole outfitted with a ¾ FPT fitting. The condensation drain is trapped internally, so generally, no external p-trap is required. A drain vent in the condensate line is required to ensure proper water flow. Terminate the condensation line into a nearby floor drain. If a floor drain is not nearby, a condensate drain pump may be used. 12/06/ GI202

25 Electrical Installation 3-phase models (both 208 and 480) also see and use GI102. WARNING DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR SERVICING THE UNIT. FAILURE TO DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THIS PRODUCT CAN CREATE A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Line Voltage The nameplate and/or Installation and Operating Manual specification page provides RLA, LRA, and total amps requirement. Select the proper wire size to comply with your type of wire routing and NEC field wiring requirements. If this unit includes AUX EL module, its own nameplate provides kw and current/voltage requirement. Power service for the AUX EL module is connected directly within this unit. The field power supply connection is at the compressor contactor, at the end of the line voltage control box. Disconnect field provided external safety disconnect is required, see nameplate max amps. Loop pumps control box, upper right, is the pump relay board with field terminal block connection for the source loop pump station and where applicable the 2 nd loop pump (load pump output applies only to water to water series). These outputs are controlled by GEO Logic, but protected with 10-amp fusing. Grounding route and install the proper size ground conductor between the ground lug above the compressor contactor and the building service entrance panel ground bus. This must be a conductor wire size according to NEC code for the total amp rating of the installed model. The conduit is not sufficient ground conductor. WARNING USE ONLY COPPER WIRE FOR CONNECTION TO THE CIRCUIT BREAKER TERMINALS AND INSIDE THIS PRODUCT S CABINET. WARNING TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH, WIRING TO THE UNIT MUST BE PROPERLY GROUNDED. FAILURE TO PROPERLY GROUND THE UNIT CAN RESULT IN A HAZARD LEADING TO PERSONAL INJURY OR DEATH. 12/06/ GI202

26 GEO Logic Controller GEO Logic Features The GEO Logic controller has a control strategy that will maximize the capabilities of the heat pump. The LED information lights on the front will communicate the THERM GEOs current stage and mode of operation. GEO Logic also has the capability to communicate diagnostic information so it can be kept running at maximum efficiency. Application The GEO Logic controller is standard on all TTHERM GEO Heat Pump models. The GEO Logic controller is designed to run under different operating modes. Basic water to air packaged unit Basic water to air packaged unit with Electro Industries strip heat Basic water to air packaged unit with added gas furnace using the LMT/INT option Basic water to air split unit, using the LMT/INT option Basic water to water packaged unit Abbreviations used in the section: ACD anti-cycle delay timer (factory 3minutes) AUX strip heat module, an option installed within the TTHERM GEO cabinet CC compressor contactor CDT compressor refrigerant discharge temperature CFM cubic feet per minute airflow COMP compressor CSL compressor safety logic subset, separate processor and power supply which monitors and controls the major compressor protection sensors DDT desuperheater refrigerant discharge temperature ECM - electronically commutated blower motor Hard Lockout the CSL has completed a sequence and shut down the compressor. The GEO Logic processes this status, forwards this status to various connections/indicators lights, and provides AUX backup heat from stat-y. This operating state is only cleared by a power reset. HUM a stat terminal relating to a humidistat function to increase cooling dehumidification. Factory default for this terminal is at 24 volts, assumes the stat is normally high and goes low when dehumidification is desired. Thus there is a peg jumper (J12) which must be removed when a stat HUM wire is connected. INT the monitor line from the LMC/SB option box indicating a declared interrupt. LED light emitting diode LMC utility load management control (off-peak = NC), identifying the device with blue and blu/wht 2-wire connection to interrupt electric usage and/or transfer the heating energy function to a standard gas/oil thermostat type terminal block. LWT source leaving water temperature RPM revolutions per minute SB standby furnace or equivalent heating unit or mode Soft Lockout reference CSL limit conditions, there is a set number of retries once lockout has been declared. When the system is operating in this retry range, for communication purposes this is considered soft lockout. ST- supply temperature (output air or water) sensor STG stage 1, 2 or 3 of electric heat WARNING TYPE OF ROOM THERMOSTAT REQUIRED USE A HEAT PUMP THERMOSTAT WITH AN O SIGNAL FOR COOLING, AND A COMPRESSOR SIGNAL Y FOR HEAT/COOL. THE THERMOSTAT NEEDS TO PROVIDE A Y2 SIGNAL IF THE UNIT IS EQUIPPED WITH TWO COMPRESSOR STAGES. THE THERMOSTAT WILL ALSO NEED TO SUPPLY A W2 SIGNAL FOR AUX HEAT WHICH MAY BE ELECTRIC OR GAS. 12/06/ GI202

27 NOTE If a programmable Thermostat is used, it is recommended that the program be set to disable. In programmable mode, the heating system must be oversized in order to recover from the setback. Since heat pumps are not typically oversized, they require a longer time to recover from the setback period. During this recovery period the system will likely call for electric heat to decrease the recovery time, resulting in lower efficiency. A closed loop performs best when the connected heat pump is allowed to cycle on and off. This cycling allows the closed loop to absorb more heat from the earth and move it into the home. The installer must be familiar with the manufacturer s low voltage wiring terminology, screw terminal terminology/colors, etc. This manufacturer s terminology must be related to TTHERM GEO heat pump s screw terminal identification within this controller. The intent of this instruction manual is not to train each installer on the terminology related to the specific product (thermostat) you are installing. ADDITIONAL OPTION: LMC/INT/SB option this is a separately mounted box with a pigtail cable that plugs into the main GEO Logic controller. It contains all the functions and wiring hookup for the utility load control receiver, gas furnace, air handler split unit, gas furnace split unit, gas boiler, thermostat E function override, and thermostat W2 function for dual fuel. In addition there are four LED s to assist in operation and troubleshooting. The design includes adequate relays for R voltage isolation between furnace/air handler and the GEO Logic Controller. Accessories/Options Part Number LMC/INT Option T2-TT-INT-1 Fuse source loop pump, 10A T9-UFUSE6670 Internal Strip Heater T2-KN-**-T PC Software and Cable (Windows 95-7) T2-ET-SOFT-GL1 Hand Held GEO Logic scan tool T2- Thermostat Simulator w/acd override T2-TT-CS-1 30 x 38 Air Pad E /06/ GI202

28 Figure 8 GEO Logic Board Assignment WARNING ANY CHANGES MADE TO SWITCH SETTIINGS, JUMPERS, OR ACCESSORIES CONNECTED TO THE GEO LOGIC CONTROLLER WILL REQUIRE THE GEO LOGIC CONTROLLER TO BE POWER CYCLED FOR THE CHANGES TO TAKE EFFECT. 12/06/ GI202

29 Field Setup Overview Thermostat Connect all the standard heat pump connections. This will require 10 conductor thermostat cable. This thermostat wire should be routed through the knockout in the top of the cabinet, in the corner above the box containing the GEO Logic controller using the proper strain relief. Terminals are as follows: E emergency/auxiliary heat R 24 volt ac power from TTERM GEO heat pump G constant fan O Activates the reversing valve for cooling mode Y 1 st stage compressor W2- starts the auxiliary heat sequence of operation Y2 2 nd stage compressor C/X 24 volt ac common from TTHERM GEO heat pump L Hard Lockout signal from TTHERM GEO heat pump HUM stat terminal relating to a thermostat with humidistat function (see definition in abbreviations, see previous page). The GEO Logic controller requires the thermostat to open a continuous 24 volt signal to activate the HUM terminal for dehumidification. Jumper J12 must be removed for this HUM function to operate. NOTE Temperature Sensors Temperature sensors installed in TTHERM GEO heat pumps are NOT thermisters. They are digital devices calibrated at the manufacturer. They are polarity sensitive. Be sure to connect the red and white wires in their correct shared terminals. The black wire is the data stream wire and will have its own screw terminal. WARNING THE DUCT SENSOR (ST) MUST BE INSTALLED ON ALL FORCED AIR MODELS. Duct Sensor (ST) install in the Geo supply air plenum, at least 24 inches (61cm) above the strip heat element (airflow inches). The ST sensor does not have an end cap; the small black electronic part just within the tube end is the actual temperature sensor. It is desirable for the air coming out of the coil to pass as close as possible to the black tip without warm-up or dampening delay. For best results, the sensor should be positioned in the maximum air stream. Other Sensor Related Comments If additional cable length is required, you must use the following rules for extending the cable. Use unshielded (low capacitance, preferred twisted) 3 or 4-wire low voltage cable. Do not, under any circumstances, use leftover wires within the normal thermostat cable. Route the sensor cable making sure you do not crimp, cut, staple, or damage the cable in any way. Keep sensor cables at least 12 (30.5cm) away from any line voltage wiring, romex, etc. If you must cross line voltage, the lines must cross at a 90 angle. Tip when working with the plug-in sensor terminal block and a cable (example, ST), start with black wire. This can help hold the cable when working with the double white and red s. The sensor has polarity, is sensitive to incorrect voltage, and must be protected from static voltage. Do not cross connect or inadvertently short out sensor wires with power on. Permanent sensor damage may result. 12/06/ GI202

30 Open or Closed Loop Jumper NOTE Open or Closed Loop Jumper J11 This jumper comes from the factory shorting the pins and is configured for open loop. For closed loop operation jumper J11 must be disabled/open. Open Loop Water Solenoid Connections The optional water solenoid 24 volt connections are located inside the cabinet near the source water out connection. The cabinet has a knock out provided for these wires. Optional Electric Heat The TTHERM GEO forced air units can be equipped with AUX electric heat. The amount of electric heat that can be installed is subject to the CFM capability of the unit. The table on page 14 (Available AUX EL Models) should be used to determine the resistance heat unit that can be used with your heat pump. To install the electric heat module the blower will need to be removed. The electric heat module will then be installed in place of the blower. The blower will be installed in the slides provided on the bottom of the electric heat module. The KN-**-T electric heat module will need high voltage connected directly from the service panel. The low voltage control consists of an 8 wire pigtail cable which plugs into the J 1 connector on the GEO Logic board. Staging is controlled through this plug-in cable from sequence drivers on the GEO Logic control board. This control cable connection enters the control board compartment through a hole in the bottom. Sequence Stat E all stages step in, 5 seconds Stat-W2 (AUX) staging delays - 1 st stage on call, 2 nd stage after 10 minutes, & 3 rd stage 10 minutes after stage 2 is initiated. All stages will remain on until the stat is satisfied Hard lockout - staging delays - 1 st stage on call, 2 nd stage after 10 minutes, & 3 rd stage 10 minutes after stage 2 is initiated. All stages will remain on until the stat is satisfied Electric Heat activated by low LWT When in heating mode and in closed loop operation, the GEO Logic controller will activate the electric heat staging if the earth loop reaches LWT set point (19 F default). The electric heat will help satisfy the stat, thus giving the earth loop a break. When the system restarts GEO Logic will not activate electric heat until the earth loop fluid again reaches19 F. Desuperheater Pump Activation The desuperheater will operate under GEO Logic control in both heat and cool modes with jumper J14 on. If jumper J14 is removed the desuperheater will only operate in heat mode. Observe the pump relay board, high voltage compartment upper right corner, there is tagged black/red wire connected to a parking tab just above the row of small relays. In this position the desuperheater pump is not active and this position acts as a manually operated switch for the desuperheater pump. After installation is complete with proper water circulation from the water heater, this tagged wire can be moved from its P tab to the SWH tab (should be open from the factory) outlined by a rectangular box. Anytime in the future there is a need to deactivate the desuperheater pump, again pull off this tagged wire and move it to the P tab (directly above the row of small relays). When plumbing the desuperheater, refer to the diagrams provided in the Desuperheater, Domestic Hot Water (SWH) section. 12/06/ GI202

31 WARNING NEVER USE PEX TUBING WHEN CONNECTING A DESUPERHEATER TO THE DOMESTIC WATER SYSTEM. NORMAL CYCLING OF THE DESUPERHEATER PUMP CAN CAUSE THE DISCHARGE WATER TEMPERATURE TO EXCEED THE RATED TEMPERATURE OF THE PEX CAUSING THE PEX TO FAIL. THIS HAS CAUSED FLOODING IN BASEMENTS. DESUPERHEATER MUST BE PLUMBED IN COPPER. WARNING THE DESUPERHEATER MOTOR SHALL NEVER BE ACTIVATED OR RUN UNTIL THERE IS PROPER CONNECTION TO THE WATER HEATER AND THE AIR HAS BEEN PURGED OUT OF THIS WATER CONNECTION. DAMAGE WILL RESULT TO THE DESUPERHEATER PUMP IF IT IS RUN DRY. Grounding The 24 volt transformer and GEO Logic board common are connected to the equipment ground terminal. The high voltage source ground (green) must be connected to the equipment ground terminal. High Voltage Wiring The TTHERM GEO heat pumps will require at least one high voltage circuit. The Electrical Data tables on page 5 will provide the information necessary to determine the correct size circuit. The high voltage wires should be routed through the knockout(s) in the top of the cabinet (in the corner above the high voltage box) or for lefthand return cabinets the power wiring can come through a side knockout and be fed straight through into the control box. WARNING HIGH VOLTAGE WIRES SHALL NEVER BE ROUTED THROUGH THE LOW VOLTAGE COMPARTMENT. The KN-**-T electric heat options will also require a separate high voltage circuit. Be sure to check the electric unit nameplate and/or manual supplied with the heater being installed for circuit requirements. Dual Fuel/Utility Control T2-TT-INT-1 option this separately mounted box with pigtail cable, plugs into the main GEO Logic controller. Applies to dual heat/dual fuel application and Split models. The enclosure is 6 W x 10 L x 3 D with 8- foot cable for plugging into GeoLogic board (J4, top center). In addition to the traditional Utility Receiver 2 blue wires, there are 5 LED s (R, status-lmc/-l/-e, backup heat, blower-y, stat-w2). This module also has the basic 6-position gas/oil furnace terminal block (R, W, G, C, Y, Y2). This design includes proper 24-volt isolation from the gas furnace transformer R. When utility interrupt applies via the T2-TT-INT-1 options box, the normal default is to interrupt both the compressor and AUX elements. However, there are utility programs where the utility only wants to interrupt the AUX elements and allow the compressor to be uninterruptible. In this later case pulling the J10 peg jumper on the GEO Logic controller will set the system up for utility interrupt of AUX elements only. 12/06/ GI202

32 Operational Indicators Front Panel LEDs: POWER ON (Green LED) ON Solid Normal Pulsing Bad sensor 1 blinks every 2 seconds - Bad ST sensor 2 blinks every 2 seconds - Bad DDT sensor 3 blinks every 2 seconds - Bad LWT sensor 4 blinks every 2 seconds - Bad CDT sensor HP STAGE 1 (Bicolor LED) RED - Heating Mode: ON Solid - Stat Y input is active. Pulsing - ACD is timing. (anti-cycle delay timer) Normal compressor delay at start up or a delay to allow refrigerant pressures or temperature sensors to reach a normal starting pressure or operating temperature range. GREEN - Cooling Mode: ON Solid - Stat Y input is active. Pulsing - ACD is timing. (anti-cycle delay timer) Normal compressor delay at start up or a delay to allow refrigerant pressures or temperature sensors to reach a normal starting pressure or operating temperature range. HP STAGE 2 (Yellow LED) ON Solid - HP-Y2 is running. Not functional on TVA models AUX HEAT (Yellow LED) ON Solid - AUX is ON. Comment three AUX LEDs on the inside of the board indicate how many stages of electric heat have been activated. Pulsing - Open safety limit. The primary high temp limit has opened in the electric heat module. 12/06/ GI202

33 EARTH LOOP FLOW/SOURCE WATER LIMIT (Red LED) ON Solid - No source flow lockout Pulsing: Open Loop - LWT < 'Open Loop, Source LWT Warning (Heat)' Closed Loop - LWT < 'Closed Loop, Source LWT Warning (Heat)'. If LWT is less than this value a shutdown with 2 x ACD s (6 min) is performed This will NOT cause a hard lockout; it is simply a warning and a pause in the system for possible system correction or notification for further service action. LO PRESSURE/LOW TEMP LIMIT (Red LED) ON Solid - Low pressure lockout Pulsing Load side discharge temperature too cold. Air - ST < 'Lo Press. Air ST Warning (Cool)' If ST is less than this value a shutdown with 2 x ACD s (6 min) is performed. This will NOT cause a hard lockout; it is simply a warning and a pause in the system for possible system correction or notification for further service action. HI PRESSURE/HIGH TEMP LIMIT (Red LED) ON Solid - High pressure lockout Pulsing Load side discharge temperature too hot. Air - ST > 'Hi Press. Air ST Warning (Heat)' If ST is greater than this value a shutdown with 2 x ACD s (6 min) is performed. This will NOT cause a hard lockout; it is simply a warning and a pause in the system for possible system correction or notification for further service action. HOT GAS/BLOWER FAILURE (Red LED) ON Solid - CDT > 'Compressor Discharge Temperature Lockout If CDT is greater than this value a soft lockout with 2 x ACD s (6 min) is performed. The 4th time this happens in the same heating or cooling cycle the unit will go into a hard lockout. Pulsing - Hard Lockout caused by ECM fault ECM fault codes are read from ECM STATUS & ECM RPM LED s on the inside of this board (see information below) 12/06/ GI202

34 Back of Circuit Board LED s STG 1-3 (Red LED s) ON when AUX stages are ON. 1 LED = 5 KW of electric heat 2 LED s = 10 KW of electric heat 3 LED s = 15 or 20 KW of electric depending on unit configuration CC (Green LED) ON when the compressor contactor (CC) is ON. ECM STATUS (Green LED) Normally ON (only if configuration is Air) ON Solid with ECM RPM LED - Model size (SW1) does not correspond to ECM motor HP read at power-up Fast Pulsing - Motor fault, ECM RPM LED will blink the fault code Pulsing in time with ECM RPM LED - Invalid Horse Power read from ECM motor on power-up (program halts) Alternating ON/OFF with ECM RPM LED: On power-up - No response from ECM motor (program halts). After power-up - Communications error ECM RPM (Yellow LED) Normally OFF Every 30 seconds blinks once for every 100 RPM of motor speed. ON Solid with ECM STATUS LED - Model size (SW1) does not correspond to ECM motor HP read at power-up Pulsing in time with ECM STATUS LED - Invalid Horse Power read from ECM motor on powerup (program halts). Alternating ON/OFF with ECM STATUS LED: On power-up - No response from ECM motor (program halts). After power-up - Communications error. Pulsing while ECM STATUS LED is blinking fast red LED counts out the fault code every 15 sec. (see Fault Codes) 12/06/ GI202

35 ECM FAULT CODES, GENTEQ 3.0 (ECM RPM LED) 1 Pulse = Control temperature above threshold 2 Pulses = Risk Addressed State (RAS), motor locked out 3 Pulses = Start procedure failed or speed too low 4 Pulses = Brownout supply voltage too low 5 Pulses = Start not successful 6 Pulses = RPM = 0 Service Tips 1. If experiencing both pulsing at same time or both solid ECM LED s and the program goes to halt, check: a. ECM motor power cable b. ECM control cable c. Motor size dial switch setting d. Correct motor for the unit model number/type 2. The LED indicated program halt condition requires power-down/power-up reset to clear. 3. Fault codes 2 and 6 cause an immediate hard lockout. 4. Fault codes 1, 3, 4, 5 or no motor data cable communication response will cause a soft lockout as described in the CSL section. 5. The ECM 3.0 motor has an internal safety function which should overcome potential software communication problems. a. Will continue at its present operating point. b. If in idle (after stop and no start command) it will stay in idle. c. If running, it will continue running at CFM established by last good data transfer. d. Above mode is set until loss of power or new successful data transfer. FAULT COUNT (Red LED, left side next to model size dial switch) Normally OFF Counts out a code for the current fault (see Fault Codes) PROGRAM FAULT CODES (FAULT COUNT LED): 1 Pulse = Lost Source Flow 2 Pulses = Refrigerant High Pressure Limit (550 psi) 3 Pulses = Refrigerant Low Pressure Limit (40 psi) 4 Pulses = Loss of refrigerant charge 5 Pulses = Under Voltage detect (source voltage less than 195 volts) 6 Pulses = CDT Safety Limit (230 degrees) 7 Pulses = See ECM Motor Fault section 8 Pulses = Lost load water flow (THA & THT units only) 9 Pulses = Leaving source water or load freeze limit 12/06/ GI202

36 High and Low Pressure Switches The heat pump is equipped with both high and low pressure switches that shut the unit off if the refrigerant pressure exceeds 550 PSI or goes below 40 PSI. Do not reset a system in the heating mode without first verifying water flow. WARNING DO NOT RESET THE SYSTEM MORE THAN ONCE REPEATED RESETTING OF THE LOCKOUT CAN CAUSE SERIOUS DAMAGE. IF A REPEAT LOCKOUT OCCURS CONTACT YOUR SERVICE DEALER IMMEDIATELY. User Visual Warnings Various front panel LED s have pulsing indication when certain key temperature parameters reach a point where system corrective action is advised. GEO Logic has default points where the manufacturer feels notification should be made. When any one of these temperature points is reached the compressor is shut down for 2 x ACD s (6 min.). At the end of this shutdown delay the compressor will again be activated as an automatic reset type function. This does not lead to a lockout, it is simply a warning and a pause in the system for possible system correction or notification for further service action. These LED s will be pulsing during the 2 x ACD (6 min.) shutdown/auto reset cycle. Default Air Trip Point Function Sensor Differential Values Increase Decrease Lo pressure ST 35 3 Hi pressure ST Loop temp. LWT 39 open, 20 closed - AUX HL Internal Fixed 20 12/06/ GI202

37 Power On Startup Before applying power to the heat pump, check the following items: 1. All plumbing and ductwork to the heat pump is complete and operational. 2. Low voltage wiring of the thermostat and any additional control wiring is complete. 3. Set thermostat to the OFF position. 4. All high voltage wiring is correct including disconnect and wire sizes. 5. The heat pump is located in a warm area above 50 F [10 C]. Starting the system with low ambient temperature conditions is more difficult. 6. You may now apply power to the unit. A 3 minute delay on power up is programmed into the GEO Logic board before the compressor will operate. This delay prevents short cycling of the unit. Note there may be additional time delays caused by the thermostat. 7. Verify source water flow specification page. Open loop systems - manually open water solenoid valve on well system to check flow. Closed loop systems operate earth loop pumps to verify flow of antifreeze protected loop fluid. The following steps will assure that your system is heating and cooling properly. After the initial time delay is completed the heat pump is now ready for operation. It is during these steps the information is collected to complete the Forced Air Heat Pump Operational Statistics sheet. This sheet is the top page of this manual. It should be removed, filled out and kept with the manual for future reference. 1. Do not connect refrigerant gauges to this unit unless the data collected indicates there is a problem. 2. Place the thermostat to the HEAT position. Turn the thermostat up to activate a 1 st stage call for heat. Pumps have an initial purge cycle, then compressor and blower will start. Check and record source water flow rate in GPM, see specification chart at the beginning of this manual for minimum water flow requirement. Check and record antifreeze protection level. 3. After the unit has run for about 3 minutes. Check and record the source side supply and return water temperatures. Check and record the supply and return air temperatures. Check and record the running voltage. Check and record the total amp draw. Check and record the compressor amp draw. 4. Raise the thermostat only enough to call 2 nd stage (if applicable). Again wait 3 minutes. Check and record the source side supply and return water temperatures. Check and record the supply and return air temperatures. Check and record the running voltage. Check and record the total amp draw. Check and record the compressor amp draw. 5. Raise the thermostat to call for AUX electric heat. Wait 3 minutes. Check and record the supply and return air temperatures Check and record the amp draw on the electric module. 6. Turn the thermostat to the off position. The compressor will shut down in a few seconds. Blower will continue to the end of the purge cycle. 12/06/ GI202

38 7. Place the thermostat in the COOL position. Turn the thermostat down to activate a 1 st stage call for cooling. The compressor will start after a 3 minute ACD period from its last shutdown. The compressor and blower will start. 8. After the unit has run about 3 minutes. Check and record the source side supply and return water temperatures. Check and record the supply and return air temperatures. Check and record the running voltage. Check and record the total amp draw. Check and record the compressor amp draw. 9. Raise the thermostat only enough to call 2 nd stage (if applicable) Check and record the source side supply and return water temperatures. Check and record the supply and return air temperatures. Check and record the running voltage. Check and record the total amp draw. Check and record the compressor amp draw. 10. Be sure all operational data has been collected and recorded on the FA Heat Pump Operational Statistics sheet. 11. Reset the thermostat to normal mode and temperature settings for the season. 12. Instruct the owner on correct operation of the thermostat and heat pump system. 12/06/ GI202

39 Operational Tips GEO Logic - The GEO Logic board performs the functions controlling the compressor operation, system lockout, compressor anti-short cycle, and a three minute delay after power is applied. Review Operational Indicator section on page 30 of this manual before proceeding. Pump/Blower Purge a stat Y call starts the blower motor, loop source pump, open loop solenoid, and desuperheater pump. The stat-y call to CSL is delayed by 5 seconds. These four items allow for circulation before the compressor is turned on. The blower motor has a 45-second turn on ramp thus it will not be noticeable during this 5-second start purge. After the time delay expires, the compressor contactor will be energized as long as the high and low pressure switches are closed. If either switch is open after the delay expires, the compressor will not energize. If either switch opens while the compressor is energized, it will de-energize immediately and begin the anti-short cycle delay. The compressor will not be allowed to turn on again until the 2 X ACD (6 minutes) expires and both pressure switches are closed. If the GEO Logic controller experiences three high pressure, low pressure soft lockouts in a single thermostat call period, it will hard lock out the compressor. During both hard and soft lockouts the fault codes are displayed. The flow switch has a bypass timer in which the GEO Logic board will ignore an open flow switch for the first 15 seconds. If the flow switch opens the GEO Logic controller will de-energize the compressor and initiate a single soft lockout. If the GEO Logic controller experiences a second flow switch fault during a single thermostat call period, it will hard lock out the compressor. NOTE This is a fluid flow limit switch; it is not a GPM sensor for determining adequate flow. It is only a flow indicator, and cannot be used to determine minimum required flow. A manual reset of power will be required to reset any hard lockout condition. At stat-y call end, loop source pump, desuperheater pump, and solenoid turn off immediately. Blower continues for 30 seconds (after the 30 seconds the blower will start its 45 second ramp down). Problems that could cause a lockout situation include: 1. Water flow problems 2. Air flow problems 3. Internal heat pump operation problems 4. Excessive cold water temperature conditions, source and load 5. Excessive hot water temperature conditions, source and load 6. Under Voltage (source voltage less than 195 volts) The GEO Logic control has a CSL Fault Count LED to indicate which type of fault or lockout has occurred. The ACD function puts a time-out period of 3 minutes on the compressor before re-starting on a normal cycle.. This function protects the compressor from repeated on/off operation in the event of a loose wire or faulty thermostat. 12/06/ GI202

40 ECM Blower Motor Hardware and Sequence GEO-Logic is equipped and programmed to operate with a Modbus/RS485 ECM motor. Each size motor is characterized to its assigned blower wheel/housing for CFM. ECM motor start is coincident with stat-y, W2, E. Programmed within the ECM motor is a 45-second ramp-up and ramp-down. The Y2 CFM becomes the reference point. There is a heat and cool Y2 CFM recorded within the GEO- LOGIC board. An 8-position dial switch selects the Y2 CFM relating to applicable installed model size. All model sizes do not have to be available or active; this is an assignment relating to the dial switch. Model Size Switch is directly below the 10 terminal thermostat block. Dial Y2 Heat Model Size ECM HP Switch CFM Y2 Cool CFM 0 TVT-024 ¾ TVA/TVT-036 ¾ TVT-042 ¾ TVA/TVT-048 ¾ TVA/TVT The thermostat wired functions have an assigned CFM related to the above. Also, the Y2/Y1 CFM can be further modified by the thermostat functions. Stat FL Comp PL/FL Comp Modifier Remarks O Determines heat/cool Y X 1.00 X 0.75 Y2 X 1.00 G X 0.40 X 0.40 W2 +15% PCC-20 E X 1.00 X % PCC-22 HUM -15% PCC-21 Y1 and Y2 can be fine-tuned or tweaked with a 4-position dial switch. This relates to both the Y1 and Y2 CFM for the selected model size dial switch. The 4-positions are 0%, -6%, +6%, +12%. The Y1 and Y2 tweak switch is found directly below the Model Size Switch. Note: This table is to show example calculations for Y and Y2 in COOLING Model Size 0% -6% +6% +12% Y Y2 Y Y2 Y Y2 Y Y2 TVT TVT TVT TVT TVT CFM Rounded 12/06/ GI202

41 The G CFM also has a fine tune or tweak 4-position dial switch, the same 0%, -6%, +6%, +12%. The G CFM tweak switch is located directly below the Y1 & Y2 tweak switch Note: This table is to show example calculations for G Model Size 0% -6% +6% +12% TVT TVT TVT TVT TVT CFM Rounded Heat or cool mode determines where the dial set percentage is applied. Power down/up is required after the model size dial switch, but the two tweak dial switches can be changed at any time. High and Low Pressure Switches The heat pump is equipped with both high and low pressure switches that shut the unit off if the refrigerant pressure exceeds 550 PSI or goes below 40 PSI. Do not reset a system in the heating mode without first verifying water flow. WARNING DO NOT RESET THE SYSTEM MORE THAN ONCE REPEATED RESETTING OF THE LOCKOUT CAN CAUSE SERIOUS DAMAGE. IF A REPEAT LOCKOUT OCCURS CONTACT YOUR SERVICE DEALER IMMEDIATELY. Pressure Switch Settings Pressure Cut Out Cut In Switch Pressure Pressure Fault Code LED Low Pressure 40 PSI 65 PSI Low Pressure ON Solid High Pressure 550 PSI 420 PSI Hi Pressure ON Solid Open Loop Freeze Protection Open loop freeze protection is accomplished by monitoring the LWT and Source Water Flow. If the LWT drops below 36 F the GEO Logic controller will de-energize the compressor and establish a LWT low temp Warning. The GEO Logic controller will continue to cycle on LWT soft lockout until the condition is corrected. The flow switch has a bypass timer in which the GEO Logic board will ignore an open flow switch for the first 15 seconds. If the flow switch opens the GEO Logic controller will de-energize the compressor and initiate a single soft lockout. If the GEO Logic controller experiences a second flow switch fault during a single thermostat call period, it will hard lock out the compressor. A manual reset of power will be required to reset any hard lockout condition. WARNING IF THE TTHERM GEO HEAT PUMP IS IN A HARD LOCKOUT WITH THE EARTH LOOP FLOW/ SOURCE WATER LED ON SOLID, DO NOT RESET THE POWER TO THIS HEAT PUMP UNTIL EARTH LOOP FLOW HAS BEEN ESTABLISHED. IF THE COMPRESSOR IS OPERATED IN HEATING MODE WITHOUT WATER FLOW, THE EARTH LOOP HEAT EXCHANGER COULD FREEZE RUPTURE. FREEZE RUPTURE IS NOT COVERED UNDER WARRANTY. 12/06/ GI202

42 Preventive Maintenance Air Filter Maintenance The Dust Free air filter in your TTHERM GEO is designed for optimum performance and long life. However, a dirty filter will result in lower efficiency and performance. Periodically, the filter should be thoroughly pressure washed in the opposite direction of airflow. Under normal operating conditions, a monthly cleaning should be satisfactory. Water Coil Maintenance In closed loop systems, water coil maintenance is generally not needed. However, if a dirty installation or deterioration of the piping has caused debris to accumulate in the system, the water coil should be cleaned using standard cleaning procedures. For open loop systems installed in areas with a high mineral content, it is best to schedule regular periodic maintenance to inspect and clean the coil if necessary. Should cleaning become necessary, do so using the following standard cleaning procedure: Chlorine Cleaning (Bacterial Growth) 1. Turn thermostat to Off position. 2. Connect a circulating pump to hose bibs on entering water and leaving waterside of heat exchanger. 3. Using a five-gallon pail of water add chlorine bleach mixture. The chlorine should be strong enough to kill the bacteria. Suggested initial mixture is 1 part chlorine bleach to 4 parts water. 4. Close shut off valves upstream and downstream of heat exchanger. 5. Open hose bibs to allow circulation of bleach solution. 6. Start pump and circulate solution through heat exchanger for 15 minutes to one hour. Solution should change color to indicate the chlorine is killing the bacteria and removing it from the heat exchanger. 7. Flush used solution down the drain by adding fresh water supply. Flush until leaving water is clear. 8. Repeat procedure until solution runs clear through the chlorine circulation process. 9. Flush entire heat pump system with water. This procedure can be repeated annually, semiannually, or as often as it takes to keep bacteria out of the heat exchanger, or when bacteria appears in a visual flow meter to the point the flow cannot be read. Muriatic Acid Cleaning - (Difficult Scaling and Particle Buildup Problems) Consult installer due to dangerous nature of acids. Iron out solutions and de-scaling products are also useful. Condensate Drip Pan and Drain Inspection and cleaning of the condensate drain system during the cooling season will help prevent the system from plugging up, potentially causing water damage to your structure and floor coverings. Inspect the flexible P-trap to make certain it remains clear of obstructions. In some areas, airborne bacteria can cause algae to grow in the drip pan. In these areas, it may be necessary to treat the drain pan with an algae inhibiting chemical, as this algae together with lint and dust could plug the drain piping. Blower Motors All TTHERM GEO s are equipped with factory sealed bearing blower motors. These motors never need additional lubrication for the life of the motor. Oiling is not recommended, as excess oil will attract lint and dust. Air Coil In order to keep your TTHERM GEO operation at peak efficiency, the air coil should be inspected and cleaned when necessary. If the coil is excessively dirty, the coil can be cleaned with a household vacuum cleaner and a soft brush. The aluminum fins are fragile and bend easily, so take great care not to damage the fins, and remember, these fins are sharp, so take the needed safety precautions. 12/06/ GI202

43 Model Stage Source Temp Source temp Δ GPM Air temp Δ Unit Operating Conditions - Heat Amps 240 Blower AMPS CFM Discharge 68 return air Discharge gas temp Sub cool at TXV Suction pressure Suction temp at bulb TVT TVT TVT TVT TVT Superheat at bulb 12/06/ GI202

44 Model Stage Source Temp Source temp GPM Air temp Δ Dry bulb Unit Operating Conditions - Cool Amps 240 Blower AMPS CFM Discharge pressure at 80 return air Discharge gas temp Sub-cool at TXV Suction pressure Suction temp at bulb Super-heat at bulb TVT TVT TVT TVT TVT /06/ GI202

45 Unit Operating Conditions - Heat Model TVA-036 TVA-048 TVA-060 Source Temp Source temp Δ GPM Air temp Δ Amps 240 Blower AMPS CFM Discharge pressure at 68 deg A-RT Discharge temp Sub cool at TXV Suction pressure at bulb Suction temp at bulb Superheat at bulb 12/06/ GI202

46 Unit Operating Conditions - Cool Model Source Temp Source temp GPM Air temp Δ Dry bulb Amps 240 Blower AMPS Nominal CFM Discharge pressure at 80 deg A- RT Discharge temp Sub-cool at TXV Suction pressure at bulb Suction temp at bulb Super-heat at bulb TVA-036 TVA-048 TVA /06/ GI202

47 Troubleshooting GEO Logic Control Sensor Temperature Calibration all four remote sensors are digital electronic and factory calibrated. Normally these do not require field calibration or verification. However, if sensor temperature error is determined, use special PC software and PC USB port cable. The PC screen has direct readout of the four monitored temperatures, it allows a visual determination of temperature settings, and can be used to offset the temperature sensors for troubleshooting and demonstration purposes. NOTE Temperature Sensors Temperature sensors installed in TTHERM GEO heat pumps are NOT thermisters. They are digital devices calibrated at the manufacturer. They are polarity sensitive. Be sure to connect the red and white wires in their correct shared terminals. The black wire is the data stream wire and will have its own screw terminal. Bad sensor, safety if the internal logic detects open sensor wire, a shorted sensor wires, or an incorrectly wired sensor; the green POWER LED reverts to a pulsing mode. Bad sensor, operating default condition the detection of bad sensor forces the controller to a fixed stage operation. Software declared bad sensor default ST = 70 F, LWT (heating) = 32 F, LWT (cooling) = 77 F, CDT = 200 F, DDT = 190 F. Check the GEO Logic Controller section of this manual for in depth description of the diagnostic information available by observing the LED s. Internal fuses the source loop, hydronic loop pumps, and desuperheater pump are fused on the high voltage pump relay board. The pump hookup decal provides the fuse size and details. Troubleshooting/Repair Helps 1. This GEO Logic controller contains several interference suppression components, but as an electronic logic product, unpredictable and unusual transients or interferences may sometimes cause strange results. If the GEO Logic controller is acting strange, one immediate step would be power down reset. Simply turn off the 240 volt source power. When the green POWER LED goes out, count to 10, and re-energize power supply. 2. The terminal blocks for control wire hook-up are designed for a wire insertion and screw clamp down. If there is no wire connected and the screw is loose, the screw may not necessarily make a good electrical contact to the inside components. Example if you jumper the thermostat terminals without thermostat wire connection or if you are attempting to measure voltage on the screw head, you may get erroneous or unpredictable results if the screw is not tightened down. 3. Use general heating/heat pump system logic information and basic understanding of the terminal block wiring functions when measuring voltage to determine proper operation. Open/Closed Loop Operation TTHERM GEO heat pumps are factory set for open loop operation. Open/Closed loop operation is set with Jumper J 11 on the left side of the GEO Logic controller. The jumper must be in place on J11 if the unit is operated on an open loop. The GEO Logic controller protects the heat exchanger from freezing by causing the compressor to shut down when the leaving water temperature reaches 38 F open loop and 20 F closed loop. The compressor will remain off for 2 ACD s, and the EARTH LOOP FLOW/ SOURCE WATER LIMIT & HP STAGE 1 LED s will pulse, while the water runs and warms up. The compressor will then restart again providing heat until the LWT again reaches 38 F open loop and 20 F closed loop. If this routine continues the heat pump will not be able to maintain the temperature in the house and the backup heat will come on. Possible causes would include: Open Loop Closed Loop 1. Supply water filter that needs cleaning 1. Inadequate source water flow 2. Inadequate source water flow 2. Antifreeze protection inadequate 3. Water discharge line that is plugging up 3. Heat exchanger needs to be cleaned 4. Entering water temperature less than 50 degrees 5. Heat exchanger needs to be cleaned 12/06/ GI202

48 WARNING IF THE TTHERM GEO HEAT PUMP IS IN A HARD LOCKOUT WITH THE EARTH LOOP FLOW/ SOURCE WATER LED ON SOLID, DO NOT RESET THE POWER TO THIS HEAT PUMP UNTIL EARTH LOOP FLOW HAS BE ESTABLISHED. IF THE COMPRESSOR IS OPERATED IN HEATING MODE WITHOUT WATER, FLOW THE EARTH LOOP HEAT EXCHANGER COULD FREEZE RUPTURE. FREEZE RUPTURE IS NOT COVERED UNDER WARRANTY. Troubleshooting the Relay board The relay board has 4 LED s which display which relay is closed. Yellow is on when open loop water solenoid is energized. Green is on when the source loop pump is running. Red is on when the desuperheater pump relay has SWH red wire at L2 voltage. Blue is on when the 2 nd source loop pump is running. The relay board has 2 10 amp fuses providing power for source loop, hydronic, and the desuperheater pumps. These fuses are 10 Amp type GSF. Checking the high voltage input terminals The high voltage enters the relay board on the upper left side, terminals W1 & W2. This high voltage comes from the source side of the contactor L1 is connected to W1 and L2 is connected to W2. WARNING DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR SERVICING THE UNIT. FAILURE TO DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THIS PRODUCT CAN CREATE A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Checking the high voltage output terminals The high voltage leaves the relay board in 2 locations. 1. Terminal Block (TB1) is located in the upper right side of the relay board. See the decal located to the right of the TB1 to determine wiring. High voltage should be present at the respective terminals when the corresponding LED is on Load pump terminals will be hot at the same time as source pump terminals. Tip if source voltage is present on the board one of the LEDs is on and high voltage is not present at the corresponding terminals the switching relay is bad and the board will need to be replaced. 2. One of the desuperheater terminals (SWH) is located between the fuses and the other SHW terminal is below the fuses. These terminals carry High Voltage. To determine if the desuperheater pump has power measure across these two terminals. If a desuperheater pump needs to be disabled be sure the high voltage to the TTHERM GEO heat pump is disabled. Remove the SHW wire from between the fuses and place it on the parking tab (P) above the relays. The relay board has one low voltage output for the 24 volt AC water solenoid. The 24VAC common wire is gray and is connected to terminal T7 on the right side of the relay board. The 24VAC hot wire is brown/yellow and is connected to terminal T4. Tip if the yellow LED #4 is on and the low voltage is not present at the water solenoid terminals, the switching relay is bad and the board will need to be replaced. 12/06/ GI202

49 Troubleshooting General WARNING Refrigerant Evacuation WHEN REFRIGERANT IS EVACUATED FROM A UNIT WITHOUT ANTIFREEZE IN THE WATER TO REFRIGERANT HEAT EXCHANGERS, WATER IN THE UNPROTECTED HEAT EXCHANGER MUST BE REMOVED OR CONTINUOUSLY FLOWING TO AVOID A POTENTIAL HEAT EXCHANGER FAILURE CAUSED BY FREEZE RUPTURE. FLOWING WATER THROUGH THE HEAT EXCHANGERS EVEN IF ANTIFREEZE PROTECTED WILL SPEED THE EVACUATION PROCESS. Troubleshooting Guide for Water-to-Air Geothermal Heating Head pressure Subcool Suction pressure Superheat Compressor Amp Draw Air temp differential Source temp differential Undercharged system Low Low Low High Low Low Low Overcharged system High High High Low High High High Low air flow High Low High High High High Low High air flow Low Low High High High Low High Low source flow Low High Low Low Low Low High High source flow High Low High High High High Low Low return air Low High Low Low Low High High temperature High return air High Low High High High Low Low temperature Scaled source coil Low High Low Low Low Low Low Restricted filter/drier Low High Low High Low Low Low Bad TXV / No Bulb charge Low High Low High Low Low Low Troubleshooting Guide for Water-to-Air Geothermal Cooling Head pressure Subcool Suction pressure Superheat Compressor Amp Draw Air temp differential Source temp differential Undercharged system Low Low Low High Low Low Low Overcharged system High High High Low High Low Low Low air flow Low High Low Low Low High Low High air flow Low Low High High High Low High Low source flow High Low High High High Low High High source flow Low High Low Low Low High Low Low return air Low High Low Low Low Low Low temperature High return air High Low High High High Low High temperature/humidity Scaled source coil High Low High High High Low Low Restricted filter/drier Low High Low High Low Low Low Bad TXV / No Bulb charge Low High Low High Low Low Low 12/06/ GI202

50 WATER-TO-AIR - HEATING MODE T-3A TXV 1/2-C T-3 AIR COIL - COND T-2A BL 7/8-B 1 RV SWH-RT P SWH COIL SWH-ST 1/2-A 140 LIMIT COMP HL LL PT SWH COIL SWH-ST SWH-RT RV AIR COIL BL TXV F/D LOOP COIL FL EWT LWT P T Name Compressor Pressure high limit Pressure low limit Pressure test port Supplementary heat exchanger Ref: WH supply Ref: WH return Reversing valve Air heat exchanger Ref: Blower Expansion valve Filter/dryer Source heat exchanger Flow switch Loop entering Loop leaving Ref: Loop pump Temperature test point T-4 F/D BULB LL PT-2 HL LOOP COIL 1/2-D 1/4-G 1 7/8-F PT-1 COMP EVAP LWT FL EWT 7/8-E 1 P P GEO LOOP FIELD TM NOTES: TON TO 6.0 TON UNITS USE 7/8 PIPE, 1.5 TON TO 3.0 TON USE 3/4 PIPE. GR201 P1 Rev. A

51 WATER-TO-AIR - COOLING MODE T-3A TXV 1/2-C T-3 AIR COIL - EVAP T-2A BL 7/8-B 1 RV SWH-RT P SWH COIL SWH-ST 1/2-A 140 LIMIT COMP HL LL PT SWH COIL SWH-ST SWH-RT RV AIR COIL BL TXV F/D LOOP COIL FL EWT LWT P T Name Compressor Pressure high limit Pressure low limit Pressure test port Supplementary heat exchanger Ref: WH supply Ref: WH return Reversing valve Air heat exchanger Ref: Blower Expansion valve Filter/dryer Source heat exchanger Flow switch Loop entering Loop leaving Ref: Loop pump Temperature test point T-4 F/D BULB LL PT-2 HL LOOP COIL 1/2-D 1/4-G 1 7/8-F PT-1 COMP COND LWT FL EWT 7/8-E 1 P P GEO LOOP FIELD TM NOTES: TON TO 6.0 TON UNITS USE 7/8 PIPE, 1.5 TON TO 3.0 TON USE 3/4 PIPE. GR201 P2 Rev. A

52

53 TTHERM GEO Residential Limited Product Warranty Effective February 1, 2012 TTHERM GEO warrants to the owner, at the original installation site, for a period of three (3) years from date of original purchase, that the product and product parts manufactured by TTHERM GEO are free from manufacturing defects in materials and workmanship, when used under normal conditions and when such product has not been modified or changed in any manner after leaving the manufacturing plant. If any product or product parts manufactured by TTHERM GEO are found to have manufacturing defects in materials or workmanship, such will be repaired or replaced by TTHERM GEO. TTHERM GEO shall have the opportunity to directly, or through its authorized representative, examine and inspect the alleged defective product or product parts. TTHERM GEO may request that the materials be returned to TTHERM GEO at owner s expense for factory inspection. The determination as to whether product or product parts shall be repaired, or in the alternative, replaced, shall be made by TTHERM GEO or its authorized representative. TEN YEAR (10) LIMITED WARRANTY ON REFRIGERATION COMPONENTS TTHERM GEO warrants that the compressor, reversing valve, expansion valve and heat exchanger(s) of its products are free from defects in materials and workmanship through the tenth year following date of original purchase. If any compressor, reversing valve, expansion valve or heat exchanger(s) are found to have a manufacturing defect in materials or workmanship, TTHERM GEO will repair or replace them at their discretion. LIFETIME LIMITED WARRANTY ON UNIT CABINET TTHERM GEO warrants that the cabinet to be free from defects in materials and workmanship for the life of the unit. If any panel fails TTHERM GEO will repair or replace them at their discretion. TTHERM GEO shall cover labor costs according to the Repair / Replacement Labor Allowance Schedule for a period of three (3) years from the date of original purchase, at the original installation site on all parts excluding the compressor, reversing valve, expansion valve, and heat exchanger(s). TTHERM GEO shall cover labor costs according to the Repair / Replacement Labor Allowance Schedule for a period of ten (10) years from the date of original purchase, at the original installation site, on parts including the compressor, reversing valve, expansion valve, and heat exchanger(s). The Repair / Replacement Labor Allowance is designed to reduce the cost of repairs. This Repair / Replacement Labor Allowance may not cover the entire labor fee charged by your dealer / contractor. TTHERM GEO TTHERMGEO.COM sales@tthermgeo.com P: F: Page 1 of 2 GX002

Water to Water Geothermal Heat Pump

Water to Water Geothermal Heat Pump Water to Water Geothermal Heat Pump Installation & Operating Instructions Model: THA/THT-*** Application Geo source closed loop or ground water Hydronic water heat/cool output Air handler, water coil,

More information

Combo Geothermal Heat Pump

Combo Geothermal Heat Pump Combo Geothermal Heat Pump Installation & Operating Instructions Model: RU-VE* Application Geo source, loop or ground water fluid Forced air vertical cabinet output Standard left ducting return, easily

More information

Two-Stage Split Geothermal Heat Pump Installation & Operating Instructions Model: (RT-SE*)

Two-Stage Split Geothermal Heat Pump Installation & Operating Instructions Model: (RT-SE*) Two-Stage Split Geothermal Heat Pump Installation & Operating Instructions Model: (RT-SE*) Application Retrofit existing forced air installations Dual Heat combine this geothermal unit and A-coil with

More information

Water to Water Geothermal Heat Pump

Water to Water Geothermal Heat Pump Application Water to Water Geothermal Heat Pump Installation & Operating Instructions Model: RA-WE* Geo source loop or ground water fluid Hydronic water heat/cool output Low temperature boiler, radiant

More information

*20D082-05NN* 20D082-05NN

*20D082-05NN* 20D082-05NN 2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

INSTALLATION NORTHERN HEAT PUMP. XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TERRA SERIES

INSTALLATION NORTHERN HEAT PUMP. XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TERRA SERIES NORTHERN HEAT PUMP TERRA SERIES ENERGY EXTRACTION SYSTEM INSTALLATION And Maintenance Manual XTERRA SERIES Horizontal and Vertical, Single and Dual Stage Geothermal Heat Pumps: FORCAIR AQUA2 SOURC3 TABLE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data...

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data... Table of Contents I. Key & Legend... 4 Key to Model Numbers... 4 Legend for Tables... 4 II. Warnings & Cautions... 5 III. General Information... 5 Inspection... 5 Storage 5 Protection... 5 Pre- Installation

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical

More information

Installation & Operation Manual Hydronic

Installation & Operation Manual Hydronic Installation & Operation Manual Hydronic Installation & Operation Manual Engineering Specifications GeoSource Hydronic Models RGS-W036 RGS-W120 This Page Intentionally Left Blank Table of Contents I. Key

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

Reinventing Energy Efficiency

Reinventing Energy Efficiency Commercial WATER2AIR EC LARGE SERIES Reinventing Energy Efficiency www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction in our

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Installation & Operation Manual Forced Air

Installation & Operation Manual Forced Air Installation & Operation Manual Forced Air Installation & Operation Manual Engineering Specifications ECONAR ColdClimate Series Forced Air Models REC-V036 REC-V060 Table of Contents I. Key & Legend...

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Antifreeze Protection 14 Electrical

More information

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit A Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit Installation, Operation & Maintenance Instructions 97B0080N01 B Table of Contents Model Nomenclature Example 3 Description and

More information

CH250 AND CH251 CHILLERS

CH250 AND CH251 CHILLERS CH250 AND CH251 CHILLERS Operator s & Installation Manual Release Date: April 19, 2004 Publication Number: 620914801 Revision Date: May 15, 2015 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The

More information

G Series. G Series 7-25 Tons Installation Manual. Water Source/Geothermal Heat Pump Commercial 7-25 Tons. Installation Information

G Series. G Series 7-25 Tons Installation Manual. Water Source/Geothermal Heat Pump Commercial 7-25 Tons. Installation Information G Series Water Source/Geothermal Heat Pump Commercial 7-25 Tons Installation Information Water Piping Connections Electrical Connections G Series 7-25 Tons Installation Manual Startup Procedures Preventive

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons Installation and Maintenance Manual Rev. 09/17/2016 Table of Contents SAFETY... 3 GENERAL DESCRIPTION... 4 MOVING AND STORAGE... 4 INITIAL

More information

AHWG Remote Mount Hot Water Generator Module

AHWG Remote Mount Hot Water Generator Module A Remote Mount Hot Water Generator Module For GT-PE (50YPS) Series Outdoor Split Unit Installation, Operation & Maintenance Instructions 97B0080N02 B Model Nomenclature Example 3 Description and Installation

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 6 System Application Options 12 Antifreeze Protection 13 Electrical

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Air Cooled Condensers 8-2016 Rev 0 Table of Contents General Safety Information 2 Inspection 2 Installation 2 6 Rigging and Assembly 2 Unit Location

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR AQUECOIL HYDRONIC HEATING UNITS GENERAL INFORMATION The AQUECOIL Hydronic Heating Unit is offered in many different capacities and physical configurations in order to match

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH 33-44-50 CAH 49-54-70 CAH VARIABLE SPEED AIR HANDLERS DIMENSIONS... 3 TECHNICAL SPECS... 4 INSTALLATION DON TS... 5 INSTALLATION DO S... 6 FREEZE STAT REQUIRED

More information

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL HOMEADVANTAGE II HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical

More information

GEOTHERMAL: THE SMARTER CHOICE

GEOTHERMAL: THE SMARTER CHOICE GEOTHERMAL: THE SMARTER CHOICE CONSUMER LITERATURE Heating and Cooling Products WHY TEMPSTAR HEATING AND COOLING PRODUCTS? Throughout the historic legacy of Tempstar Heating and Cooling Products, the company

More information

INSTALLATION MB SERIES MANUAL TABLE OF CONTENTS MB SERIES ( INSTALLATION ) UNIT DESCRIPTION. FHP MB series are available in two models: VH CABINET:

INSTALLATION MB SERIES MANUAL TABLE OF CONTENTS MB SERIES ( INSTALLATION ) UNIT DESCRIPTION. FHP MB series are available in two models: VH CABINET: MB SERIES ( INSTALLATION ) INSTALLATION MANUAL MB SERIES TABLE OF CONTENTS Unit Description...1 Installation...2 General...2 Safety Considerations...2 Moving and Storage...3 Location...3 Acoustical Considerations...3

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

EC SERIES MODEL NOMENCLATURE

EC SERIES MODEL NOMENCLATURE EC SERIES Table of Contents Model Nomenclature...1 Introduction...2 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE: INSTALLATION INSTRUCTIONS DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System Model: DORGPT-1 NOTE: This guide provides the installer with instructions specific to the Bard Double O-Ring Geo-Prime

More information

DXair Pool Dehumidifiers

DXair Pool Dehumidifiers DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Desuperheater Kit 15 Antifreeze

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

R-410A AFFINITY SERIES DEX DEY Ton

R-410A AFFINITY SERIES DEX DEY Ton R-410A AFFINITY SERIES 024-048 DEY060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations......................................

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

INSTALLATION INSTRUCTIONS WARRANTY

INSTALLATION INSTRUCTIONS WARRANTY QT FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. Low Head Pump Center Flow Chart Fig. 2. High Head Pump Center Flow Chart NOTE: Read the entire instruction manual before starting the installation. WARRANTY

More information

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Daikin Water Cooling, Heating, and High Capacity Booster Coils Installation and Maintenance Manual IM 900 Daikin Water Cooling, Heating, and High Capacity Booster Coils Group: Applied Air Part Number: IM 900 Date: February 2008 Types HI-F5, E-F5 2008 Daikin International

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

Geothermal. Comfort Systems

Geothermal. Comfort Systems Geothermal Comfort Systems As an ENERGY STAR partner, Carrier Corporation has determined that the Geothermal Comfort System meets ENERGY STAR guidelines for energy efficiency. The Carrier Geothermal Advantage

More information

FORCED AIR + HYDRONIC

FORCED AIR + HYDRONIC FORCED AIR + HYDRONIC The WaterFurnace Synergy3D series provides forced air heating & cooling and hydronic heat for radiant floors in one convenient package. It was engineered with leading edge components,

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

Versatec Ultra Series Installation Manual

Versatec Ultra Series Installation Manual Commercial Geothermal/Water Source Heat Pump R-410A Refrigerant 0.75-6 Tons Installation Information Water Piping Connections Hot Water Connections Electrical Startup Procedures Versatec Ultra Series Installation

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

AP SERIES VOLTAGE DESIGNATION: 1-208/1/60 & 230/1/60 CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW

AP SERIES VOLTAGE DESIGNATION: 1-208/1/60 & 230/1/60 CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW Table of Contents Model Nomenclature...1 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate Drain...3 Duct System...3

More information

Installation and Operating Instructions. GeoSource DualTEK. Vertical and Horizontal Forced Air/Hydronic GV/GH 36 Thru 67 Series

Installation and Operating Instructions. GeoSource DualTEK. Vertical and Horizontal Forced Air/Hydronic GV/GH 36 Thru 67 Series 1 Installation and Operating Instructions GeoSource DualTEK Vertical and Horizontal Forced Air/Hydronic GV/GH 36 Thru 67 Series GeoSource DualTEK Vertical Unit Air Filter Blower Air Coil Contactor Transformer

More information

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER 1103 N HIGH CROSS RD URBANA, IL 61802 1-773-492-1893 INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER REV 1.0 The Geo-Boost system consists of the Geo-Boost heat exchanger and a relay controller

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: TSU TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

Installation and Service Manual

Installation and Service Manual Installation and Service Manual W-Series Liquid to Water Geothermal Heat Pump Two-Stage R410a Model Sizes 25-80 Maritime Geothermal Ltd. P.O. Box 2555 Petitcodiac, NB E4Z 6H4 (506) 756-8135 Email: info@nordicghp.com

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

Owner s Information Manual

Owner s Information Manual 50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

SM Field Installed Electric Heat Kit

SM Field Installed Electric Heat Kit SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation

More information

EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions

EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Desuperheater Kit 15 Anti-Freeze

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

COMMON WATERSIDE ECONOMIZER APPLICATIONS: APPLICATION MANUAL WATERSIDE ECONOMIZER TABLE OF CONTENTS Safety Approvals...1 Common Waterside Economizer Applications...1 Sequence of Operation (Single)...1 Cooling Mode...2 Heating Mode...2 Sequence

More information

Geothermal Comfort Systems

Geothermal Comfort Systems Geothermal Comfort Systems The Bryant Geothermal Advantage Throughout Bryant's historic 100-year legacy, the company has provided millions of homeowners with the finest comfort systems available. Using

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HB Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 042, 048, 060 TE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE. SAFETY

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

GS SERIES. Table of Contents CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW

GS SERIES. Table of Contents CABINET CONFIGURATION: VT - VERTICAL HZ - HORIZONTAL CF - COUNTERFLOW Table of Contents Model Nomenclature...1 Initial Inspection...2 General Description...2 Moving and Storage...2 Safety Considerations...2 Location...2 Installation...2 Condensate Drain...3 Duct System...3

More information

Commercial Water Source Heat Pump Water Heater Operations and Installation Manual

Commercial Water Source Heat Pump Water Heater Operations and Installation Manual GEYSER C-250W Commercial Water Source Heat Pump Water Heater Operations and Installation Manual Geyser 250W Manual Version 2.2 Nyle Systems 12 Stevens Rd Brewer, ME 04412 www.nyle.com info@nyle.com 800-777-6953

More information

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater. Duct Heaters Synheat duct heaters come in various sizes and dimensions to fit any compartment. There are three types of duct heaters available: open coil, tubular element or finned tubular heating elements

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information