AIR HANDLER DESIGN WORK SHEET

Size: px
Start display at page:

Download "AIR HANDLER DESIGN WORK SHEET"

Transcription

1 AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD] CURB: BY OTHERS BY THERMAL CURB STYLE: STD DWL W/ INS SEISMIC (OUTSOURCED) CURB HEIGHT: UNIT CONSTRUCTION: CF-SERIES (WELDED & FORMED FRAME, NO THERMAL BREAK) F-SERIES (SCREWED & FORMED FRAME, THERMAL BREAK) T-SERIES (WELDED & STRUCTURAL FRAME, THERMAL BREAK) TS-SERIES (SCREWED & EXTRUDED FRAME, 100% THERMAL BREAK) D-SERIES (LIMITED SCREWS ON EXTERIOR, FORMED FRAME, THERMAL BREAK) SPECIAL (EXPLAIN) EXTERIOR PANEL: 18 GA. 16 GA. 14 GA. OTHER EXTERIOR METAL TYPE: G90 GALV. [ STAINLESS STEEL: ] ALUMINUM INSULATION: R VALUE INCHES THICK TYPE: [ FIBERGLASS: 1.5# 3#] FOAM NONE FLOOR: MIN GA STEEL CHECKER PLATE ALUMINUM CHECKER PLATE OTHER LINER: NONE (CF-SERIES ONLY) SOLID (20 GA) LOCATION (SECTION) PERF. (20 GA) LOCATION EXTERIOR PAINT FINISH: NONE EPOXY POLYURETHANE OTHER SPECIAL COLOR INTERNAL PAINT FINISH: NONE EPOXY POLYURETHANE OTHER SPECIAL COLOR INLET/OUTLETS SUPPLY AIR DISCHARGE: UNIT END FLOOR TOP/ROOF OTHER RETURN AIR INLET: UNIT END FLOOR TOP/ROOF SIDE OTHER Page 1 of 6

2 EXHAUST AIR DISCHARGE: UNIT END FLOOR TOP/ROOF SIDE OTHER OUTSIDE AIR INLET: UNIT END FLOOR TOP/ROOF SIDE OTHER AIR BLENDER ACCESS DOORS NOTE: MINIUM DOOR WIDTH FOR VIEW WINDOW IS xx, ALL DOORS SMALLER THEN THIS WILL NOT GET A WINDOW. (AIRSIDE) LIFT OFF HINGED HANDLES: CAMLOCKS STD TOOL OPERATED KEY OPERATED WINDOWS (SIDE LOADING FILTER ACCESS DOORS CANNOT HAVE WINDOWS) (SERVICE) (ELEC./GAS) LIFT OFF HINGED HANDLES: CAMLOCKS STD TOOL OPERATED KEY OPERATED WINDOWS OTHER BLOWER S/A BLOWER: VOLUME SCFM ESP W.C. BLOWER ACCESS: R.H.S. L.H.S. TYPE: FC BI AF BELT DRIVE PLEN DIRECT DRIVE PLEN FAN ARRAY EBM EC (SELECT SIZE BELOW) SIZE QTY CLASS SCREENS: INLET OUTLET MOTOR: HP ODP TEFC EXP PROOF SHAFT GROUNDING RING OTHER VOLTAGE: PHASE: HZ: VFD: ENCLOSURE: NEMA 1 NEMA 3R DRIVE TYPE: DRIVE ONLY W/ DISCONNECT W/ DISC. & BYPASS DISCONNECT OPTIONS: CIRCUIT BREAKER BYPASS OPTIONS: 2 CONTACTOR 3 CONTACTOR NEMA 3R OPTIONS: SURGE PROTECTOR SPACE HEATER COMMUNICATION OPTIONS: MODBUS BACNET APOGEE METSYS ETHERNET/IP LONWORKS Page 2 of 6

3 EXTENDED WARRANTY (VFD ONLY): TOTAL YEARS (FIVE YEARS MAX, STD ONE YEAR) ON SITE START UP (VFD ONLY) R/A BLOWER: VOLUME SCFM ESP W.C. BLOWER ACCESS: R.H.S. L.H.S. TYPE: FC BI AF BELT DRIVE PLEN DIRECT DRIVE PLEN FAN ARRAY EBM EC (SELECT SIZE BELOW) SIZE QTY CLASS SCREENS: INLET OUTLET MOTOR: HP ODP TEFC EXP PROOF SHAFT GROUNDING RING OTHER VOLTAGE: PHASE: HZ: VFD: ENCLOSURE: NEMA 1 NEMA 3R DRIVE TYPE: DRIVE ONLY W/ DISCONNECT W/ DISC. & BYPASS DISCONNECT OPTIONS: CIRCUIT BREAKER BYPASS OPTIONS: 2 CONTACTOR 3 CONTACTOR NEMA 3R OPTIONS: SURGE PROTECTOR SPACE HEATER COMMUNICATION OPTIONS: MODBUS BACNET APOGEE METSYS ETHERNET/IP LONWORKS EXTENDED WARRANTY (VFD ONLY): TOTAL YEARS (FIVE YEARS MAX, STD ONE YEAR) ON SITE START UP (VFD ONLY) ISOLATED BASE OPTIONS: ISOLATION: NONE INTERNAL SEISMIC SPECIAL INERTIA BASE(S) DETAIL S/A R/A DRIVES: STD. SPECIAL SERVICE FACTOR BELT GUARD: STD. OSHA BEARINGS: STD. OTHER EXT. LUBE LINES: NONE TO ACCESS SIDE OTHER DFILTERSD PRE: MERV ANGLE FLAT SIDE LOAD FACE LOAD METAL FRAME FILTER GAUGE SPARE SET(S) QUANTITY S/A R/A FINAL: MERV ANGLE FLAT SIDE LOAD FACE LOAD METAL FRAME BOLT LOCK CRANK LOCK FILTER GAUGE SPARE SET(S) QUANTITY S/A R/A HEATING PREHEAT COIL CFM: MAX FACE VEL: SPECIFIED COND. EA F DB LA F DB MBH FLUID: WATER GLYCOL [ ETHYLENE PROPYLENE] % EWT: F LWT: F MAX GPM: MAX WATER PRESSURE DROP: STEAM: DISTRIBUTING (TUBE IN TUBE DESIGN) NON-DISTRIBUTING PSI: Page 3 of 6

4 TUBE MATL: CU SS TUBE SIZE: 1/2 5/8 1 (FOR DISTRIBUTING COILS ONLY) TUBE WALL: NOTE: TUBE WALL VARIES BASED ON TUBE SIZE FIN MATERIAL: AL CU SS FIN THICKNESS: MAX FPI: CONNECTIONS: THREADED FLANGED VICTAULIC SWEAT COATING: NONE HERESITE ELECTROFIN OTHER: REHEAT COIL CFM: MAX FACE VEL: SPECIFIED COND. EA F DB LA F DB MBH FLUID: WATER GLYCOL [ ETHYLENE PROPYLENE] % EWT: F LWT: F MAX GPM: MAX WATER PRESSURE DROP: STEAM: DISTRIBUTING (TUBE IN TUBE DESIGN) NON-DISTRIBUTING PSI: TUBE MATL: CU SS TUBE SIZE: 1/2 5/8 1 (FOR DISTRIBUTING COILS ONLY) TUBE WALL: NOTE: TUBE WALL VARIES BASED ON TUBE SIZE FIN MATERIAL: AL CU SS FIN THICKNESS: MAX FPI: CONNECTIONS: THREADED FLANGED VICTAULIC SWEAT COATING: NONE HERESITE ELECTROFIN OTHER: ELECTRIC HEATER ELECTRIC HEATER KW: POWER: VOLTAGE: PH: HZ: CONTROL TYPE: STAGED: # OF STAGES: SCR: [ 0-10VDC 4-20MA] OTHER NOTES: COOLING COOLING COIL CFM: MAX FACE VEL: SPECIFIED COND. EA F DB/WB LA F DB/WB MBH FLUID: WATER GLYCOL [ ETHYLENE PROPYLENE] % EWT: F LWT: F MAX GPM: MAX WATER PRESSURE DROP: DX (EVAPORATOR) REFRIGERANT: SUPER HEAT TEMP: F SUCTION TEMP: F LIQUID TEMP: F TUBE MATL: CU SS TUBE SIZE: 1/2 5/8 TUBE WALL: NOTE: TUBE WALL VARIES BASED ON TUBE SIZE FIN MATERIAL: AL CU SS FIN THICKNESS: MAX FPI: CONNECTIONS: THREADED FLANGED VICTAULIC SWEAT (DX ONLY HAS SWEAT TYPE CONNECTIONS) Page 4 of 6

5 COATING: NONE HERESITE ELECTROFIN OTHER: GAS HEAT INDIRECT GAS HEATER: 304 SS TUBES STD CONTROL BOX TYPICALLY EXTERIOR TO UNIT FUEL: NAT. GAS PROPANE PRESSURE W.C. TEMP. RISE F BTUH IN BTUH OUT TURNDOWN REQ. ENERGY/HEAT RECOVERY HEATPIPE HEATWHEEL PLATE HEAT EXCHANGER OTHER: WINTER COND.: SUPPLY AIR EAT DB/WB F LAT DB/WB F OR RH % EXHAUST AIR EAT DB/WB F LAT DB/WB F OR RH % TOTAL/SENSIBLE MBH RECOVERED WINTER COND.: SUPPLY AIR EAT DB/WB F LAT DB/WB F OR RH % EXHAUST AIR EAT DB/WB F LAT DB/WB F OR RH % STEAM HUMIDIFIER TOTAL/SENSIBLE MBH RECOVERED HUMIDIFIER GRID (DISPERSION TUBE) DRAIN PAN DESIRED SECTION LENGTH INSULATED GRID STRAINER TRAP VALVE W/ ACTUATOR: SPECIFY TYPE (2 POS./MOD./SPRING RTN/PWR VOLT/CNTR VOLT) STEAM BY OTHERS ELEC. STEAM GENERATOR GAS STEAM GEN STEAM TO STEAM GEN (EXGR TYPE) ELECTRICAL PRIMARY SUPPLY (BROUGHT TO UNIT) VOLTAGE: PHASE: HZ: SECOND POINT SUPPLY (BROUGHT TO UNIT) VOLTAGE: PHASE: HZ: SINGLE POINT POWER (STEP DOWN TRANSFORMER FOR 120V) UNIT DISCONNECT CONVENIENCE LIGHTS AND RECEPTACLES WIRED BY FACTORY TO SINGLE POINT CONVENIENCE OUTLETS: UNIT EXT. UNIT INT. MARINE LIGHTS (STD ONE SWITCH AT FAN DOOR) QTY SWITCH PER LIGHT WITH PILOT LIGHT NOTES: ACCESSORIES AIR MONITOR STATION TYPE: Page 5 of 6

6 SOUND REQUIREMENTS: SOUND TEST: LEAK TEST: DEFLECTION REQUIREMENT: LABLING: UNIT FUNCTION: (DESCRIBE THE CONTROL SEQUENCE OF BLOWERS, DAMPERS, HEAT, COOLING, SET-BACK INTERLOCKS, ECT.) MISCELLANEOUS COMMENTS: Page 6 of 6

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model DXH Custom, packaged, roof mounted or indoor mounted unit with cooling (DX or Chilled Water) and an air-to-air aluminum flat plate exchanger designed to provide pre-cooling and reheat. The DXH is

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

RT-OA TM Rooftop Outdoor-Air (DOAS)

RT-OA TM Rooftop Outdoor-Air (DOAS) RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS (DX - Air Source Data) Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels,

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

Multi-Path RTU-TYPE 2

Multi-Path RTU-TYPE 2 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 2 (RTU1) CESMPU025RHVAV2 Date: February 17, 201 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV2 Unit features include: 25 Ton MultiPath

More information

Item Title No. of Copies

Item Title No. of Copies 110-400 Fort Whyte Way, Oak Bluff, MB, R4G 0B1 TEL. (204) 231-1094 FAX. (204) 231-1661 E-mail: sveto@ambassadormechanical.com 0BTRANSMITTAL SHEET To: Saher Kilada Project: Southeast Collegiate Con-Pro

More information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing April 2016 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Architecture - Engineering - Planning

Architecture - Engineering - Planning Architecture - Engineering - Planning www.mkcinc.com Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 9-55-0 - phone 0-6-887 - phone 70-657-0 - phone 9-55-8 - fax 0--075 - fax 70-657-77 - fax SHOP DRAWING

More information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing April 2012 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete

More information

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration Destiny Indoor Air Handler Models 002 030 Catalog 580-8 Horizontal Configuration Vertical Configuration Table of Contents Introduction.... 2 Certification...2 Smoke Control and Management Systems...2 Features

More information

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing March 2010 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Tulsa, OK Longview, TX

Tulsa, OK Longview, TX Tulsa, OK Longview, TX An Overview, presented by: Custom Air & Power Официальный дистрибьютор в России - Компания ООО «Альфа Инвест Инжиниринг» 109052, г.москва, ул. Нижегородская, д. 50 Сайт: www.ai-engineering.ru

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

CoolSpot Engineering Guide

CoolSpot Engineering Guide Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

LETTER OF TRANSMITTAL

LETTER OF TRANSMITTAL LETTER OF TRANSMITTAL FRANK A. ANZALONE Date: FAA Job No. 157 GENERAL CONTRACTOR Attention: Mr. Brent Guilbeau - Coleman Partners 1401 Derek Drive, Suite B Hammond, LA 70403 3377 North Boulevard Phone:

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

FAS Fresh Air Supply Units

FAS Fresh Air Supply Units TGFAS-2 FAS Fresh Air Supply Units TECHNICAL GUIDE STEAM AND HOT WATER MAKE-UP AIR HEATERS WITH INTEGRAL FACE AND BYPASS COILS FOR EFFECTIVE TEMPERATURE CONTROL Since 1875, the L.J. Wing Company has been

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

DES CHAMPS PRODUCTS 85% 4,400 CFM

DES CHAMPS PRODUCTS 85% 4,400 CFM DES CHAMPS PRODUCTS Saves up to 85% of the heat from exhaust airstream Removes pollutants before they accumulate Transfers heat energy in winter/cool energy in summer Low cost Capacities up to 4,400 CFM

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual Engineering Manual From 1 to 3 Tons MC-2x2-2x2 MissionCritical Vertical Floor Mounted A/C s (Single Circuit DX & CW) R407C & R410a Data ta 1 to 3 Tons Compact 24 W x 24 D Footprint Features & Benefits

More information

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm) Heat Recovery Units AIR HANDLING UNIT No. SERVICE AREA MANUFACTURER MODEL HRU-3 & HRU-4 B-Section Low Rate Ventilation Tempeff RG 16000 (9500) SUPPLY FAN - SIZE/TYPE AIRFLOW RATE (cfm) (l/s) TOTAL STATIC

More information

THE ULTIMATE ROOFTOP SOLUTION

THE ULTIMATE ROOFTOP SOLUTION Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22) Engineering Manual R407c & R410a SC SpotCool 2 x 4 Packaged & Split Ceiling Mounted A/C s (DX & CW Systems) Features & Benefits 1 to 3 Ton Capacities Comfort Applications - General Office Spaces - Conference

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE

SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE Fresh Access Pro http://freshaccesspro.com/erep/ This guide is intended for use by qualified professionals to assist in properly

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler

More information

Technical Development Program

Technical Development Program Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

PRODUCT CATALOG BLOWER COILS.

PRODUCT CATALOG BLOWER COILS. 2016 PRODUCT CATALOG BLOWER COILS www.superiorrex.com SBH / SBV Series Design Features DESIGNED FOR MAXIMUM FLEXIBILITY Both Horizontal and Vertical Belt Drive Blower Coils are designed to maximize flexibility

More information

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

Convectors Steam / Hot Water November, 2009

Convectors Steam / Hot Water November, 2009 Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.

More information

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual Liebert Mini-Mate2 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz Technical Data Manual Technical Support Site If you encounter any installation or operational issues with

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 9/16/2011 Reference

More information

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant

More information

Now In Production JULY 2008

Now In Production JULY 2008 Now In Production JULY 2008 OptiSolar, McClellan, CA Nine (9) Custom new single-zone units with 135 tons of DX cooling, air cooled condensing sections and direct drive supply air blowers. Ambient design

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-532 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant RHGM- 090 & 120 SERIES NOMINAL SIZES 7.5 & 10, TONS [26 & 35 kw] TABLE OF CONTENTS Unit Features...3

More information

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms SKY-COM HI-CAP SERIES Precise Environmental Control SKY-COM 15 & 20 TON Series Suited for Telecommunications, Laboratories and Computer Rooms GENERAL MECHANICAL SPECIFICATIONS AIRFLOW CONFIGURATION Units

More information

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons Product Data 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial

More information

SAS Steadyair Make-Up Air Units Technical Guide

SAS Steadyair Make-Up Air Units Technical Guide TGSAS-3 SAS Steadyair Make-Up Air Units Technical Guide A COMPLETE AIR TEMPERING PACKAGE FOR COMMERCIAL, INSTITUTIONAL, AND INDUSTRIAL APPLICATIONS S ince 1875, the L.J. Wing Company has been a leader

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SO TOUGH, WE GUARANTEE IT. SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SSL SBS www.superiorrex.com SSL / SBS Series: BIG ON FEATURES; SMALL IN SIZE Contractors All SSL/SBS model blower-coil

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RQ SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RN SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

SSL & SBS Engineering Guide

SSL & SBS Engineering Guide REDUCED-FOOTPRINT VERTICAL BLOWER COIL UNITS SSL & SBS Engineering Guide SO TOUGH, WE GUARANTEE IT. SSL SBS Table of Contents Features and Benefits... 3 Construction Features... 4 Features and Options...

More information

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank A C P S C STACT Model Designations Model Number: STACT8S6 ST AC T ST = Portable Scroll Chiller AC = Air Cooled WC = Water Cooled T = With Process Tank 8 8 = Model Size* S 6 XP / LT S = Single Refrigeration

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils Energy Efficient Easy to Install Extended Service Life Engineered to save our customers money Eliminate the belt and pulleys Energy efficient EC Motor Improve indoor air quality Nominal CFM range of 00

More information

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual Indoor Cooling Perimeter STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol Self-contained Precision Air Conditioner Utilizing EC Fan Technology

More information

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL MODEL DESCRIPTION Table of Contents The LAYTON Advantage... Total Protection----------------------------------------------------------

More information

Direct Gas-Fired Make-Up Air Models DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING RN SERIES Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units Installation, Operation, & Maintenance WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 - TABLE OF CONTENTS Page No Introduction... 2 Nomenclature... 2 Components... 3 Standard Features... 3 Optional Accessories... 5 Cooling and Heating Portfolio... 5 Physical Specifications... 6 System Cooling

More information

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018 ` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with

More information