Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Size: px
Start display at page:

Download "Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features"

Transcription

1 THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5 Btuh) Hz Green Refrigerant R-4A The Bard WA/L S Series features a multi-step capacity compressor with environmentally friendly non-ozone depleting refrigerant. The Bard Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between high and low capacity operations without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cycling for improved system life. Multi-Step Capacity Compressor: Copeland step-capacity scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. R-4A Refrigerant: Designed with R-4A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2 EPA requirements. ECM Indoor Blower Motor: Features a variable speed motor providing super-high efficiency, low sound levels and soft-start capabilities. The motor is selfadjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. All models feature variable speed blower motors providing automatic airflow adjustment for high static or free blow (non-ducted) operation at a very low sound level. Motor overload protection is standard on all models. Foil Faced Insulation: on all units. Start Kit: A PTCR compressor start assist (Positive Temperature Coefficient Resistor) is standard on all -A single-phase models to increase system reliability. This helps to insure compressor starts at adverse conditions by increasing the compressor starting torque. Compressor Control Module: Built-in off-delay timer adjustable from 3 seconds to 5 minutes. 2-minute on-delay if power interrupt. 2-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Liquid Line Filter Drier: on all units. Protects system against moisture. High & Low Pressure Switches are Auto-Reset: on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Crankcase Heaters: Factory installed crankcase heaters are standard on all models. This helps to insure ease of start at low temperatures and improves compressor life. Phase Rotation Monitor: on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per ASTM B7-3. Galvanized Gauge Zinc Coated Unit Base: The unit base is treated with the same paint coatings as the cabinet above, insuring years of service without visible corrosion. Drain Pan: The evaporator drain pan is constructed of stainless steel material for maximum corrosion resistance. Complies with efficiency requirements of ASHRAE/IESNA.-23. Certified to ANSI/ARI 3-23 for SPVU (Single Package Vertical Units). Intertek ETL Listed to for Safety Heating and Cooling Equipment ANSI/UL 5/CSA 22.2 No. 23-5, Fourth Edition. Commercial Product - Not intended for Residential application. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features line break automatic limit and dual backup safety controls. Heater packages can be factory or field installed for all models. Filter Service Door: Separate service door provides easy access for filter change. Two-Inch, Pleated Disposable Air Filters: Are standard equipment. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Circuit Breakers/Rotary Disconnect: on all versions of single (23/2 volt) and three phase (23/2 volt) equipment. Rotary disconnects are standard on all versions of three phase (4 volt) equipment. Slope Top: feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Top Rain Flashing: feature on all models. Bard is an ISO :2 Certified Manufacturer Form No. S Supersedes S Page of 2

2 Capacity and Efficiency Ratings Models Cooling Capacity BTUH, 2nd Stage Operation EER 2nd Stage Operation jk Rated CFM (Wet Coil) Cooling Capacity BTUH, st Stage Operation EER st Stage Operation k Rated CFM (Wet Coil) 35,2.4 24,4.7, ,.7 5, ,. 3 IPLV l Certified in accordance with ANSI/ARI 3-23 for single package vertical units. EER = Energy Efficiency Ratio - BTU/WATT efficiency. Integrated Part Load Value - BTU/WATT efficiency and certified in accordance with ANSI/ARI All capacity, efficiency and cost of operation information is based on operation with fresh air cover plate. Cover plate is recommended for use to obtain maximum energy efficiency where ventilation air is not required. Indoor Blower Performance - CFM (. through. H 2 O) Blower Only st Stage Cooling 2nd Stage Cooling 5- KW Electric Heat 5-2 KW Electric Heat These systems contain Variable Speed ECM Motor, which maintains airflow across static range at dry and wet coil conditions. Specifications 3 Ton through 5 Ton MODELS -A -A -B -B -C -C -A -A -B -B -C -C -A -A -B -B -C -C Cooling Capacity 35,2 35,2 35,2,5,5,5 5,5 5,5 5,5 Heating Capacity Electrical Rating Hz 23/2-23/ /2-23/ /2-23/ Operating Voltage Range Compressor Circuit A Voltage 23/2 23/2 4 23/2 23/2 4 23/2 23/2 4 Rated Load Amps 2.3/4..7/7. 3../../ /2. 5.5/. 7. Branch Circuit Selection Current Lock Rotor Amps 2 / 2 5 / 5 3 / / 4 / 23 / 23 2 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD / / / / / / / / Fan Motor--Amps / Fan--DIA/CFM 24" " " " " " " " " - 2 Blower Motor & Evap. Blower Motor--HP-RPM-SPD See Electric Heat Table /2-Variable /2-Variable /2-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable 3/4-Variable Blower Motor--Amps CFM Cooling & E.S.P Filter Size 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 Basic Unit Weight --LBS Blank-Off Plate Motorized Fresh Air Damper Commercial Room Ventilator Economizer Energy Recovery Ventilator Form No. S Supersedes S Page 2 of 2

3 Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a blank off plate as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BLANK OFF PLATE - BOP STANDARD A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. Motorized Fresh Air Damper MIS-35 NOTE: This vent system is intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Other building systems will govern actual amount of intake air. Commercial Room Ventilator Economizer Energy Recovery Ventilator MIS-3 MIS-3 MIS-37 COMMERCIAL ROOM VENTILATOR - CRVMP OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper with integral bug screen. Automatic control is integrated to maintain desired ventilation air at the various supply airflows. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is power open - spring return on power loss. Complies with ANSI/ ASHRAE 2. Ventilation for Acceptable Indoor Air Quality. ECONOMIZER - ECONWM-Series OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. ECONWMT Equipment Building versions have extended air intake hood to deliver up to % of cooling rated airflow. ECONWMS versions have 3 air intake hood to deliver up to % of cooling rated airflow. Features: Fully modulating Honeywell Direct Drive Hi-Torque Actuator No linkage required Simple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE 2.. The ERV allows from 2 to CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the WA/LS model wall-mount units. It can be built-in at the factory or field installed as an option. ERVF-*5 can be independently adjusted for intake and exhaust rates. Form No. S Supersedes S Page 3 of 2

4 CRVMP-5 WA3S/WL3S Ventilation Airflow 7 Ventilation Airflow (CFM) Stage #2 Operation Blower Only & Stage # Operation Vent Position CRVMP-5 WA4S/WL4S Ventilation Airflow 7 Ventilation Airflow (CFM) 5 4 Stage #2 Operation Stage # Operation Blower Only Vent Position CRVMP-5 WA5S/WL5S Ventilation Airflow 7 Ventilation Airflow (CFM) Stage #2 Operation Stage # Operation Blower Only 2 Form No. S Supersedes S Page 4 of Vent Position

5 Performance and Application Data- WERV-*5 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/2 WB) DB/ WB Ambient O.D. VENTILATION RATE -- CFM VENTILATION RATE -- 3 CFM VENTILATION RATE -- 3 CFM F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL Ambient O.D. WERV-*5 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE CFM 3 CFM 3 CFM DB/ F WVL WHR WVL WHR WVL WHR NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. S Supersedes S Page 5 of 2

6 Electrical Specifications MODEL -AZ -A5 -A -A -A5 -A2 Rated Volts & Phase 23/2- No. Field Power Circuits or 2 or 2 or 3 Minimum Circuit Ampacity Maximum External Fuse or Ckt. Brkr. 7 5 Single Circuit Multiple Circuit Field Power Wire Size 3 2 Ground Wire Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Field Power Wire Size Ground Wire Size Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C BZ -B -B -B5 23/ CZ -C -C -C AZ -A5 -A -A -A5 -A2 23/2- or 2 or 2 or BZ -B -B -B5 23/ CZ -C -C -C AZ -A5 -A -A -A5 -A2 23/2- or 2 or 2 or BZ -B -B -B5 23/ CZ -C -C -C Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Form No. S Supersedes S Page of 2

7 Electric Heat Table Nominal KW Kw At 24V () At 2V () At 4V (2) At 4V (2) -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh , , , , , , , , , ,3.. 3, , , , , , , , , ,5 () These electric heaters are available in 23/2V units only. (2) These electric heaters are available in 4V units only. Heater Packages - Field Installed WA3, WA4 & WA5S Designed for adding Electric Heat to KW Units Circuit Breaker on 23/2V Models Air Conditioner Models -A Models 23/2- ETL US & Canada Listed Toggle Disconnect on 4V Models -B Models 23/2-3 -C Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW EHWA4S-A5B EHWA5S-AB EHWA4S-AB EHWA4S-A5B EHWA4S-A2B EHWA3S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 EHWA4S-A5B EHWA5S-AB EHWA4S-AB EHWA4S-A5B EHWA4S-A2B EHWA5S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 EHWA5S-A5B EHWA5S-AB EHWA5S-AB EHWA5S-A5B EHWA5S-A2B EHWA5S-BB EHWA5S-BB EHWA5S-B5B 5 EHWA5S-C EHWA5S-C EHWA5S-C5 5 Heater Packages - Field Installed WL3, WL4 & WL5S Designed for adding Electric Heat to KW Units Circuit Breaker on 23/2V Models Air Conditioner Models -A Models 23/2- ETL US & Canada Listed Toggle Disconnect on 4V Models -B Models 23/2-3 -C Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW EHWA4S-A5LB EHWA5S-ALB EHWA4S-ALB EHWA4S-A5LB EHWA4S-A2LB EHWA3S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 EHWA4S-A5LB EHWA5S-ALB EHWA4S-ALB EHWA4S-A5LB EHWA4S-A2LB EHWA5S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 EHWA5S-A5LB EHWA5S-ALB EHWA5S-ALB EHWA5S-A5LB EHWA5S-A2LB EHWA5S-BLB EHWA5S-BLB EHWA5S-B5LB 5 EHWA5S-CL EHWA5S-CL EHWA5S-C5L 5 Form No. S Supersedes S Page 7 of 2

8 Acoustical Plenum WAPR Free Blow Acoustical Plenum WAPFB5 2 /4" 42 3/" 3 3/4" /2" 42 /4" 3 3/4" /2" 3/" 7/" 3 3/4" 34 /4" /2" 2 7/" /2" MIS-224 A 2 /" 7" MIS-22 A Optional Installation Accessories Description Model Color Acoustical Plenum Ducted Supply Air Acoustical Plenum Free Blow Supply Air Acoustical Plenum WAPR-X WAPR-4 Beige Buckeye Gray Shipping Weight (Lbs.) 25 WAPS5-G Galvanized 4 WAPFB5-X WAPFB5-4 Beige Buckeye Gray 7 Supply Air Acoustical Plenum WAPS5-G 44" 2" 5" 7/" 4" 5 3/4" 2 7/" 4" " MIS-24 2" DIA. HOLES FOR DUCT COLLARS. DUCT COLLARS FIELD SUPPLIED. Typical installation with isolation curb, free blow, supply air acoustical plenum & return air acoustical plenum. WMICF5 ISOLATION CURB WAPF5 FREE-BLOW SUPPLY AIR PLENUM WMICF5 ISOLATION CURB WAPF5 FREE-BLOW SUPPLY AIR PLENUM WAPR RETURN AIR ACCOUSTICAL PLENUM WAPR RETURN AIR ACCOUSTICAL PLENUM Patent Pending Form No. S Supersedes S Page of 2 MIS-24

9 Typical Sound Performance with Installation/Isolation s & Acoustical Plenums WA/L3S Sound Data Matrix feet) Unit Mounting Supply Air Treatment Treatment Blower Only Operation with CRV Compressor Stage Operation with CRV Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X WAPR-X Indoor Integrated dba Compressor Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. WA/L4S Sound Data Matrix feet) Unit Mounting Supply Air Treatment Treatment Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X Blower Only Operation Compressor Stage Operation Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation WAPR-X Indoor Integrated dba Compressor Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. WA/L5S Sound Data Matrix feet) Unit Mounting Supply Air Treatment Treatment Free Blow Configuration Direct Isolation WAPFB5 Free Blow Supply Air Plenum WAPR-X Direct Ducted Supply Configuration Direct Isolation Isolation WAPS5-G Supply Air WAPR-X Blower Only Operation Compressor Stage Operation Compressor Stage 2 Operation Compressor Stage 2 with ERV High Speed Operation WAPR-X Indoor Integrated dba Compressor Stage Outdoor Sound Level Note : dba is sound pressure measured feet in front of unit and 5 feet above floor. Note 2: Unit or isolation curb is mounted to frame construction. Note 3: Results may vary depending upon other factors such as room size, type of construction and acoustical variances. Form No. S Supersedes S Page of 2

10 2nd Stage Cooling Application Data - Outdoor Temperature Model D.B./W.B. k Cooling Capacity BTU/HR 5 F 55 F F 5 F 7 F F F 5 F F 5 F F 5 F F 5 F /2 44,25 42,5 4, 4,325 3,5 37, 3,55 35,3 34,5 32, 3,4 3,5 2,25 27,5 32,3 3,5 3,3 3,7 3,225 2,7 2,2 2,7 2,2 27,7 27,25 2,35 25, 25, /7 4,5 47, 4, 44, 43,2 4,7 4,25 3,55 3, 35,2 34,225 33, 3, 3, 32,3 3, 3,225 3,5 3, 2,5 2,4 2,3 27, 27, 2,25 2, 25, 25,3 5/72 53,5 5,7 5,25 4, 47,35, 44,4 43,5 4,25 4,2 3,5 37, 35,55 34, 32, 3,55 3,5 3,525 3,25 2,5 2, 2,5 2, 27,5 2,25 2,35 25,7 25,2 /2 5,25 53, 5,5 5,5 4,525 4,4 4,5,5 44,5 42, 4,7 3,5 37,25 35,3 4, 4, 3, 3,7 3,25 37,3 3,725 3,5 35,5 35, 34, 33, 32, 3, /7 2,725 5, 5, 55,5 53,325 53, 5,7 4, 47,,5 44,4 42,5 4,425 3, 4, 4,3 4,4 3,5 3, 37, 3,7 35, 34, 34, 33, 32, 32,35 3, 5/72,425,7 4, 2,, 5, 57, 5,5 54,25 52,2 5,3 4,55 4,725 44, 4,25 4,5 4,725 3,25 3,5 37, 37, 3,3 35,5 34,7 33, 33,25 32,525 3, /2,35 7,525 5,7 3, 2,,25 5,425 5,25 54,25 53, 5,5 4,3 47,, 4,5 4, 4, 47,325 4,5,, 44,325 43, 42,5 4, 4, 4,2 3,3 /7 74, 72,7 7,,,25 4,5 2,7, 5, 5,5 54,5 53,4 5,5 5,3 4,325 47,55 4,,, 44,4 43,5 42, 4,7 4, 4,4 4,5 3,25 3,5 5/72 7,3 77,5,5 74,225 72,525 7,,2 7,,225 4,7 2,25 5,7 57,325 54,5 4,425,,35 44,25 44,2 43, 43,2 42, 42,325 4,5 4, 4,325 3,5 3, st Stage Cooling Application Data - Outdoor Temperature Model D.B./W.B. k /2 /7 5/72 /2 /7 5/72 /2 /7 5/72 Cooling Capacity BTU/HR Below 5 F, unit requires a factory or field-installed low ambient control. Return air temperature F. 5 F 55 F F 5 F 7 F F F 5 F F 5 F F 5 F F 5 F 3,25 2,2 2,3 27,35 2,3 25,4 24, 23,5 22,55 2, 2,55,5, 7,4 22,7 22,3 2,25 2,35 2, 2,4,5,5,5,,25 7,,,3 34,3 33,5 32,25 3, 2, 2, 27, 2,3 25,5 24,4 22, 2, 2,7, 23, 22,5 22,5 2,525 2,25 2,5,,425,,35 7,25 7,4 7,5, 37, 3,7 35,525 34,35 33, 32, 3,25 2,5 2,4 27,3 2,25 24,25 23, 22,55 22,4 22, 2, 2,2 2, 2,4 2,25,5,2,,425 7,25 7,,5 4, 3, 3, 37,525 3,3 35,3 34,2 33, 32, 3, 2, 2,3 27, 25,7 2, 3, 2,4 2,25 2,4 27, 2,4 25,5 25,425 24, 24,325 23, 23, 22,,3 43,5 42,225 4,5 3, 3, 37, 3,5 35,25 34, 32,25 3,25 2, 2,5 2, 3, 2,55 2, 2, 27, 2,55 2, 25, 24, 24,35 23,7 23,225 22,5 5,2 4, 4,5, 43,725 43, 42,4 4, 3,4 37, 3, 35,3 34, 32,7 3,25 2, 2, 2,3 27, 27,4 2,725 2,25 25,35 24,5 24, 23,7 23,225 22, 5,3 4,5 47,725 4,4, 43, 42,55 4,35 4,5 3,5 37,5 35,325 33,525 3,7 37,25 3,5 3,5 35,525 35, 34, 33, 33,5 33,25 32,55 3,7 3,25 3,2 2,5 5,25 5, 54, 52, 5, 4,5 4,5 44,425 42,225 4, 3,7 37,55 3,325 35, 3, 3,4 35, 35,3 34,5 34,35 33, 32,525 3,25 3,7 3,25 32,25 34,5 35,5 2,55, 5,5 57,3 55,55 53, 52,5 5,2 4,525 4,,5 43,35 4,5 3,5 3,25 35,7 35,3 34,25 34,3 33, 33,4 33,25 32, 32,5 3, 3, 3,4 2, Clearances Required for Service Access and Adequate Condenser Airflow Intake MODELS LEFT SIDE RIGHT SIDE WA/L3S, WA/L4S, WA/L5S 2" 2" Minimum Clearances Required to Combustible Materials MODELS SUPPLY AIR DUCT FIRST THREE FEET CABINET WA/L3S, WA/L4S, WA/L5S /4" " Refer to the Installation Manual for more detailed information. Unit Charge Rates (R-4A) UNIT / - High Efficiency RH/LH Step Capacity A/C / - High Efficiency RH/LH Step Capacity A/C / - High Efficiency RH/LH Step Capacity A/C Std. Unit - Lbs Form No. S Supersedes S Page of 2

11 Dimensions of Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WIDTH (W) DEPTH (D) HEIGHT (H) SUPPLY RETURN All dimensions are in inches. Dimensional drawings are not to scale. A B C B E F G I J K L M N O P Q R S S2 T WA3-4-5S Models W Built In Rain Hood 4 Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for ERV and ECONWMS models only D 2.3 A I Side Wall Mounting Brackets (Built In) Top Rain Flashing Shipping Location E O Supply Air Opening B.44 R S S 5. F G Filter Access Panel Ventilation Air Condenser Air Outlet flush vent 3" door for non-erv/ Econ. models " Low Voltage Hood for Electrical ECONWMT Entrance models. High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Opening S S2 S2 T Front View Side View Drain N Q Back View Bottom Installation Bracket MIS-3234 R S S Built In Electric E Rain Hood Heat Heater O 4 Pitch Access.44 Panel D C. Breaker/ W 2.3 Disconnect Access Panel Side Wall Supply Air Opening (Lockable) Mounting A Brackets flush (Built In) vent door for B non-erv/econ. models Top Rain Flashing Shipping Location I.25 Hood used on ERV and ECONWMS only WL3-4-5S Models S Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air 5. F S2 S2 T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet Side View " Hood for ECONWMT models. Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View Not used when ECONWMT Economizers installed. Filter access is through the ECONWMT hood. G MIS-324 B Form No. S Supersedes S Page of 2

12 Air Conditioning Wall-Mount Model Nomenclature MODEL NUMBER WA Right Hand WL Left Hand CAPACITY 3S - 3 Ton 4S - 4 Ton 5S - 5 Ton WA 3S 3 A B P X X X X Ventilation Options REVISION WA 3 WL 2 VOLTS & PHASE A - 23/2// B - 23/2//3 C - 4//3 Models Description KW VENTILATION OPTIONS (See Chart Below) FILTER OPTIONS P - 2 inch Pleated MERV COLOR OPTIONS X - Beige () - White 4 - Buckeye Gray 5 - Desert Brown - Dark Bronze A - Aluminum S - Stainless Steel NOTE: For KW and circuit breakers (23/2 Volt) or rotary disconnect (4 Volt) applications, insert Z in the KW field of the model number. Factory Installed Code No. All Models Field Installed Part No. Blank-Off Plate B BOP-5 Motorized Fresh Air Damper M MFAD-5 Commercial Ventilator - Motorized w/exhaust V CRVMP-5 Economizer - Versions, Enthalpy m S ECONWMS-E5B* k Economizer - Equipment Building, Enthalpy n W ECONWMT-E5B* k Economizer - Equipment Building, DB Temp n T ECONWMT-T5B* k Energy Recovery Ventilator - 23 Volt l R ERVF-A5 j Energy Recovery Ventilator - 4 Volt l R ERVF-C5 j Door Kit for ERVF (Required) N/A WMDK5- l Intake and exhaust can be independently adjusted. Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.) WMDK Door Kit must be ordered in addition to ERVF Assembly and color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.) Partial Full Flow (% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood. Full Flow (% of Rated Cooling CFM). ALL ECONWMT versions have " deep intake hood. CONTROL MODULES (See Chart Below) COIL OPTIONS X - - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator & Condenser SUPPLY AIR OUTLET X - Front () Air Conditioning Control Modules AVAILABLE CONTROL OPTIONS ALL MODELS HPC LPC CCM LAC ALR SK DDC p Factory Installed Code Field Installed Part STD STD STD STD X N/A STD STD STD STD H CMA-2 STD STD STD STD J Factory Only STD STD STD STD V p Factory Only STD = equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. CCM. Compressor control module has adjustable 3-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to F. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. SK. Start kit standard on all -A single phase models only. Is not used or available for -B or -C three phase models. DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. Form No. S Supersedes S Page 2 of 2 Bard Manufacturing Company, Inc. Bryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S337 December 27 Supersedes S352-77

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Q/Tec TM QW-Series Water-to-Air Heat Pumps Heating Capacities: 6,4 to 45,5 BTUH Capacities:, to 53,5 BTUH : 3. to 3.5 : 3.4 to 6.6 Q/Tec TM QW-Series Water-to-Air Heat Pumps The Q/Tec series self contained packaged water-to-air heat pump is designed

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications .5 to 3 Ton 2V to 4V hz Air Conditioner Specifications EER WA Series WALL-MOUNT.5 to 3 Ton V to 4V EER hz AirWA Conditioner Specifications. TM Series WALL-MOUNT Wall-Mount Air Conditioner is a self nergy

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: W7A2-A WA2-A W24A2-A W24A2-B W24A2-C W24A2-D W24A2-F WA2-A WA2-B WA2-C WA2-D WA2-F WA2-A WA2-B WA2-C WA2-D WA2-E WA2-F W42A2-A W42A2-B

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification I-TEC I30AD-IAD 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification Cooling Capacities: 20,0 to 54,000 Btuh The Bard I-TEC Air Conditioner system is designed for classrooms

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Guide. Wallmount. Air Conditioners & Heat Pumps Product Guide Wallmount Air Conditioners & Heat Pumps Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS J7A2 J7L2 J24A2 J24L2 JA2 JL2 J3A2 J3L2 J42A2 J42L2 J4A2 J4L2 JA2 JL2 J70A2 J70L2 Manual : 0-5A Supersedes: 0-5 File: Volume III Tab

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3 WGERV-C3 WGERV-A5 WGERV-C5 BARD MANUFACTURING COMPANY Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual:

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use with Bard 3-1/2 Through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH84 WH242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 200-423C Supersedes: 200-423B

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-007 QWSERV 90-08 QWSERV with Intelligent Defrost For Use With Bard Through 5 Ton QW*S Series Bard Manufacturing Company, Inc. Bryan,

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR INSTALLATION INSTRUCTIONS Models: ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR For Use with Bard 2 Thru 5 Ton "P" Series Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan,

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner Bard High Sensible Cooling Systems HR36 Series 12.5 EER 2 to 3 Ton HR58 Series 11.0 EER 3.5 to 5 Ton The FUSION-TEC TM has been

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS WH W24H WH W3H W42H W4H W0H Bard Manufacturing Company, Inc. Bryan, Ohio 43 Since 94...Moving ahead just as planned. Manual : 20-5B Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS Models WH3 WH43 WH49 Bard Manufacturing Company, Inc. Bryan, Ohio 436 Since 94...Moving ahead just as planned. Manual : 20-342I Supersedes: 20-342H

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-09 QWSERV with Occupied Air Capabilities For Use With Bard Through Ton QW*S Series Bard Manufacturing Company, Inc. Bryan, Ohio

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A2B WERV-A3C WERV-C2B WERV-C3C For Use With Bard 1-1/2 Through 3 Ton Wall Mount Air Conditioners and Heat Pumps

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners Bard Manufacturing's revolutionary MEGA-TEC WALL-MOUNT sets the industry standard for flexibility. Engineered to cool virtually any equipment building

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc. INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual: 21-495 Supersedes:

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH184 WH242 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-423A Supersedes: 2100-423

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use With Bard 3-1/2 through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH42 WH43 WH2 BARD MANUFACTURING COMPANY Bryan, Ohio 4350 Since 94...Moving ahead, just as planned. Manual: 20-399 Supersedes: File: Volume

More information