GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal

Size: px
Start display at page:

Download "GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal"

Transcription

1 REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal Furnace GUH92A Upflow / Horizontal Furnace GUH95A Upflow / Horizontal Furnace GDD80A Downflow Furnace GDD92A Downflow Furnace GDD95A Downflow Furnace 80+ AFUE 92.1% & 95.0% AFUE GUH80A Upflow / Horizontal Replacement Parts List... Page 2 GDD80A Downflow Replacement Parts List... Page 3 Upflow / Horizontal Component Location... Page 4 Downflow Component Location... Page 5 GUH92A Upflow / Horizontal Replacement Parts List... Page 6 GDD92A Downflow Replacement Parts List... Page 7 GUH95A Upflow / Horizontal Replacement Parts List... Page 8 GDD95A Downflow Replacement Parts List... Page 9 Upflow / Horizontal Component Location... Page 10 Downflow Component Location... Page 11

2 GUH80A UPFLOW / HORIZONTAL NON-CONDENSING GAS FURNACE - 80% + AFUE ITEM DESCRIPTION 045A3XE 054A3XE 072B4XE 090B4XE 072C5XE 090C5XE 108C5XE 126D5XE 1 Door Set Y Y Y Y Y Y Y Y 2 Top Panel R R R R R R R R 3 Collector Pan with gasket Inducer Motor Inducer Gasket (Not Shown) R R R R R R R R 6 Transformer Control Board Fuse Pressure Switch R R R R R R R 10 Heat Exchanger Main Air Limit R Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R R R 15 Inshot Burner Manifold, Burner Tube R R R R R R R Orifice, Main Burner, Nat. Gas R R R R R R R R 18 Flame Sensor R R R R R R R R 19 Gas Valve Roll-Out Switch Door Switch R R R R R R R R 22 Blower Assembly Blower Housing Assembly R R R R R R R R 24 Capacitor Motor, Blower Wheel, Blower R R R R R R 27 Blower Limit Repl. Motor Mount Kit N/A N/A Hose, High Temp (Not Shown) R R R R R R R R 30 Set of Wires (Not Shown) M R M R M R M R M R M R M R M R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 4. 2

3 GDD80A DOWNFLOW NON-CONDENSING GAS FURNACE - 80% + AFUE ITEM DESCRIPTION 054A3XE 072B4XE 090B4XE 108C5XE 126D5XE 1 Door Set Y Y Y Y Y 2 Top Panel R R R R R 3 Collector Pan With Gasket Inducer Motor Inducer Gasket (Not Shown) R R R R R 6 Combustion Tube Transformer Control Board Fuse Pressure Switch R R R R R 11 Heat Exchanger Main Air Limit Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R 16 Inshot Burner Manifold, Burner Tube R R R R R 18 Orifice, Main Burner, Natural Gas R R R R R 19 Flame Sensor R R R R R 20 Gas Valve Roll-out Switch Door Switch R R R R R 23 Blower Assembly Blower Housing Assembly R R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit Repl. Motor Mount Kit N/A Hose, High Temperature (Not Shown) R R R R R 31 Set of Wires (Not Shown) M R M R M R M R M R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 5. 3

4 GUH80A 80% + UPFLOW / HORIZONTAL COMPONENT LOCATION

5 GDD80A 80% + DOWNFLOW COMPONENT LOCATION

6 GUH92A UPFLOW / HORIZONTAL CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 038A3XE 054B4XE 072B4XE 072C5XE 090C5XE 108D5XE 120D5XE 1 Door Set Y Y Y Y Y Y Y 2 Top Panel 2B3551R 2B3552R 2B3552R 2B3553R 2B3553R 2B3554R 2B3554R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R R 6 Inshot Burner Manifold, Burner Tube R R R R R R R 8 Orifice, Main Burner, Nat. Gas R R R R R R R 9 Flame Sensor R R R R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R R R Not Used Not Used 18 Inducer Limit Outlet Header Box Pressure Switch (condensate) Pressure Switch (inducer) R R R R R R 22 Transformer Door Switch R R R R R R R 24 Blower Assembly Blower Housing Assembly R R R R R R R 26 Capacitor Motor, Blower Wheel, Blower R R R R R R 29 Blower Limit Repl. Motor Mount Kit N/A In-Line Drain Assembly R R R R R R R 32 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R R R R 34 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 6.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R R R R 37 Set of Wires (Not Shown) M M R M R M R M R M R M R 38 Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 10. 6

7 GDD92A DOWNFLOW CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 054B4XE 072B4XE 090C5XE 120D5XE 1 Door Set Y Y Y Y 2 Top Panel 2B3562R 2B3562R 2B3563R 2B3564R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R 6 Inshot Burner Manifold, Burner Tube R R R R 8 Orifice, Main Burner, Natural Gas R R R R 9 Flame Sensor R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R Not Used 18 Inducer Limit Outlet Header Box Pressure Switch (inducer) R R R R 21 Transformer Door Switch R R R R 23 Blower Assembly Blower Housing Assembly R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit/Blower Deck Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R 31 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R 33 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 5.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R 36 Set of Wires (Not Shown) M M M M Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 11. 7

8 GUH95A UPFLOW / HORIZONTAL CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 038B4XE 054B4XE 072C5XE 090C5XE 108D5XE 120D5XE 1 Door Set Y Y Y Y Y Y 2 Top Panel 2A9512R 2A9512R 2A9513R 2A9513R 2A9514R 2A9514R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R 6 Inshot Burner Manifold, Burner Tube R R R R 8 Orifice, Main Burner, Nat. Gas R R R R R R 9 Flame Sensor R R R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit R R R R 16 Inducer Motor Inducer Orifice R R R R R 18 Inducer Limit Outlet Header Box Pressure Switch (Condensate) R R 21 Pressure Switch (Inducer) R R R Transformer Door Switch R R R R R R 24 Blower Assembly Blower Housing Assembly R R R R R R 26 Capacitor Motor, Blower Wheel, Blower R R R R R R 29 Blower Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R R R 32 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R R R 34 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 6.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R R R 37 Set of Wires (Not Shown) M R M R M R M R M R M R 38 Finish Flange, Inlet Air PVC Trap (Not Shown) R R R R R R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 10. 8

9 GDD95A DOWNFLOW CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 054B4XE 072C5XE 090C5XE 118D5XE 1 Door Set Y Y Y Y 2 Top Panel 2B3562R 2B3563R 2B3563R 2B3564R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R 6 Inshot Burner Manifold, Burner Tube Orifice, Main Burner, Natural Gas R R R R 9 Flame Sensor R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R R 18 Inducer Limit Outlet Header Box Pressure Switch (Inducer) R R R Transformer Door Switch R R R R 23 Blower Assembly Blower Housing Assembly R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit/Blower Deck Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R 31 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R 33 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 5.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R 36 Set of Wires (Not Shown) M M M M Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 11. 9

10 GUH92A & GUH95A UPFLOW / HORIZONTAL COMPONENT LOCATION 14 GUH92A Models GUH95A Models

11 GDD92A & GDD95A DOWNFLOW COMPONENT LOCATION GDD92A Models GDD95A Models 11

12 Specifications & illustrations subject to change without notice or incurring obligations (11/13) B (Replaces A)

GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)

GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING

More information

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41

More information

FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)

FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) www.source1parts.com HVAC SERVICE PARTS Supersedes: 650.75-RP1U (1199) 035-17790-001 Rev. A (1102) 1 of 8 13 5 9 8 61 6 10 4 2 11 12 7 3 16 1 14 15

More information

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF A Series 15 SEER Models REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper repair

More information

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE

More information

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11

More information

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13

More information

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16

More information

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM

More information

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE

More information

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31

More information

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG

More information

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8

More information

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35

More information

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001

More information

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.

More information

2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)

2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) 2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure

More information

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44

More information

UPFLOW NATURAL GAS FURNACES - 90%

UPFLOW NATURAL GAS FURNACES - 90% Y W R G C UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-17489-000 Rev. C (1201) 035-17489-000 Rev. D (302) 1 of 8 13 5 8 10 4 2 9 6 14 11 1 COOL HEAT CIR 12

More information

REPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace GCVC80603BXBC GCVC80803BXBC GCVC80805CXBC GCVC81005CXBC This manual is to be used by qualified technicians only. 2016 Goodman Manufacturing

More information

PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES

PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8

More information

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44

More information

2 STAGE UPFLOW NATURAL GAS FURNACES (94+)

2 STAGE UPFLOW NATURAL GAS FURNACES (94+) 2 STAGE UPFLOW NATURAL GAS FURNACES (94+) HVAC SERVICE PARTS Supersedes: 035-17482-000 Rev. E (1102) 035-17482-000 Rev. F (0304) 1 of 8 Figure 1: 2-STAGE UPFLOW NATURAL GAS FURNACES (94+) P1XUB12N05501

More information

PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)

PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS GMPN Multi-Positional Gas Furnace GMPN040-3 GMPN060-3 GMPN080-4 GMPN100-4 GMPN120-5 nufacturing Company, L.P. San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to be

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)

FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure

More information

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2. P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

P3HU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) (STYLES A & B, INCLUDING LOW NOX)

P3HU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) (STYLES A & B, INCLUDING LOW NOX) www.source1parts.com HVAC SERVICE PARTS PHU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (0%) (STYLES A & B, INCLUDING LOW NOX) Supersedes: 0-1-000 Rev. C (06) 0-1-000 Rev. D (0) 1 of 1 1 1 1 1 6,0 Figure

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001

More information

Energy Saving. Space Saving.

Energy Saving. Space Saving. Energy Saving. Space Saving. An Unbeatable Combination! 92% Gas Furnace Comfort, efficiency, and dependability make an unbeatable combination in the 92% gas furnace! Energy Savings Two heat exchangers

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE MULTIPOISE CONDENSING GAS Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

FSB Series II Gas-Fired Hot Water Induced Draft Boilers FSB Series II Gas-Fired Hot Water Induced Draft Boilers Models FSB- FSB-3 FSB-4 FSB-5 FSB-6 FSB-7 REPAIR PARTS AND OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When ordering

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

Comfort, Quality and Efficiency.

Comfort, Quality and Efficiency. Comfort, Quality and Efficiency. An Unbeatable Combination! 80% Gas Furnace This low profile gas furnace stands tall in features and fuel economy Models are available in upflow/horizontal and downflow

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG: Submittal Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH Downflow Only S9V2C100D4PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10 General

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: S96VA Multi-Position Gas Furnaces FORM NO. GSC-540 REV. 5 Sure Comfort S96VA 96% A.F.U.E. Two-Stage Variable Speed Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72

More information

Installation Instructions

Installation Instructions Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev. 036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

GV Series 4 Section Assembly

GV Series 4 Section Assembly GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel

More information

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

Ruud Achiever Series Multi position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS MULTIPOISE CONDENSING GAS FURCE Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................

More information

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,

More information

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX2B060A9362A, TUX2B080A922A, TUX2C100A982A, TUX2D1A9602A, TDX2B060A9362A, TDX2B080A922A, TDX2C100A982A,

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information