GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal"

Transcription

1 REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal Furnace GUH92A Upflow / Horizontal Furnace GUH95A Upflow / Horizontal Furnace GDD80A Downflow Furnace GDD92A Downflow Furnace GDD95A Downflow Furnace 80+ AFUE 92.1% & 95.0% AFUE GUH80A Upflow / Horizontal Replacement Parts List... Page 2 GDD80A Downflow Replacement Parts List... Page 3 Upflow / Horizontal Component Location... Page 4 Downflow Component Location... Page 5 GUH92A Upflow / Horizontal Replacement Parts List... Page 6 GDD92A Downflow Replacement Parts List... Page 7 GUH95A Upflow / Horizontal Replacement Parts List... Page 8 GDD95A Downflow Replacement Parts List... Page 9 Upflow / Horizontal Component Location... Page 10 Downflow Component Location... Page 11

2 GUH80A UPFLOW / HORIZONTAL NON-CONDENSING GAS FURNACE - 80% + AFUE ITEM DESCRIPTION 045A3XE 054A3XE 072B4XE 090B4XE 072C5XE 090C5XE 108C5XE 126D5XE 1 Door Set Y Y Y Y Y Y Y Y 2 Top Panel R R R R R R R R 3 Collector Pan with gasket Inducer Motor Inducer Gasket (Not Shown) R R R R R R R R 6 Transformer Control Board Fuse Pressure Switch R R R R R R R 10 Heat Exchanger Main Air Limit R Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R R R 15 Inshot Burner Manifold, Burner Tube R R R R R R R Orifice, Main Burner, Nat. Gas R R R R R R R R 18 Flame Sensor R R R R R R R R 19 Gas Valve Roll-Out Switch Door Switch R R R R R R R R 22 Blower Assembly Blower Housing Assembly R R R R R R R R 24 Capacitor Motor, Blower Wheel, Blower R R R R R R 27 Blower Limit Repl. Motor Mount Kit N/A N/A Hose, High Temp (Not Shown) R R R R R R R R 30 Set of Wires (Not Shown) M R M R M R M R M R M R M R M R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 4. 2

3 GDD80A DOWNFLOW NON-CONDENSING GAS FURNACE - 80% + AFUE ITEM DESCRIPTION 054A3XE 072B4XE 090B4XE 108C5XE 126D5XE 1 Door Set Y Y Y Y Y 2 Top Panel R R R R R 3 Collector Pan With Gasket Inducer Motor Inducer Gasket (Not Shown) R R R R R 6 Combustion Tube Transformer Control Board Fuse Pressure Switch R R R R R 11 Heat Exchanger Main Air Limit Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R 16 Inshot Burner Manifold, Burner Tube R R R R R 18 Orifice, Main Burner, Natural Gas R R R R R 19 Flame Sensor R R R R R 20 Gas Valve Roll-out Switch Door Switch R R R R R 23 Blower Assembly Blower Housing Assembly R R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit Repl. Motor Mount Kit N/A Hose, High Temperature (Not Shown) R R R R R 31 Set of Wires (Not Shown) M R M R M R M R M R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 5. 3

4 GUH80A 80% + UPFLOW / HORIZONTAL COMPONENT LOCATION

5 GDD80A 80% + DOWNFLOW COMPONENT LOCATION

6 GUH92A UPFLOW / HORIZONTAL CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 038A3XE 054B4XE 072B4XE 072C5XE 090C5XE 108D5XE 120D5XE 1 Door Set Y Y Y Y Y Y Y 2 Top Panel 2B3551R 2B3552R 2B3552R 2B3553R 2B3553R 2B3554R 2B3554R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R R 6 Inshot Burner Manifold, Burner Tube R R R R R R R 8 Orifice, Main Burner, Nat. Gas R R R R R R R 9 Flame Sensor R R R R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R R R Not Used Not Used 18 Inducer Limit Outlet Header Box Pressure Switch (condensate) Pressure Switch (inducer) R R R R R R 22 Transformer Door Switch R R R R R R R 24 Blower Assembly Blower Housing Assembly R R R R R R R 26 Capacitor Motor, Blower Wheel, Blower R R R R R R 29 Blower Limit Repl. Motor Mount Kit N/A In-Line Drain Assembly R R R R R R R 32 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R R R R 34 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 6.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R R R R 37 Set of Wires (Not Shown) M M R M R M R M R M R M R 38 Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 10. 6

7 GDD92A DOWNFLOW CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 054B4XE 072B4XE 090C5XE 120D5XE 1 Door Set Y Y Y Y 2 Top Panel 2B3562R 2B3562R 2B3563R 2B3564R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R 6 Inshot Burner Manifold, Burner Tube R R R R 8 Orifice, Main Burner, Natural Gas R R R R 9 Flame Sensor R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R Not Used 18 Inducer Limit Outlet Header Box Pressure Switch (inducer) R R R R 21 Transformer Door Switch R R R R 23 Blower Assembly Blower Housing Assembly R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit/Blower Deck Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R 31 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R 33 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 5.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R 36 Set of Wires (Not Shown) M M M M Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 11. 7

8 GUH95A UPFLOW / HORIZONTAL CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 038B4XE 054B4XE 072C5XE 090C5XE 108D5XE 120D5XE 1 Door Set Y Y Y Y Y Y 2 Top Panel 2A9512R 2A9512R 2A9513R 2A9513R 2A9514R 2A9514R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R R R 6 Inshot Burner Manifold, Burner Tube R R R R 8 Orifice, Main Burner, Nat. Gas R R R R R R 9 Flame Sensor R R R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit R R R R 16 Inducer Motor Inducer Orifice R R R R R 18 Inducer Limit Outlet Header Box Pressure Switch (Condensate) R R 21 Pressure Switch (Inducer) R R R Transformer Door Switch R R R R R R 24 Blower Assembly Blower Housing Assembly R R R R R R 26 Capacitor Motor, Blower Wheel, Blower R R R R R R 29 Blower Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R R R 32 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R R R 34 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 6.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R R R 37 Set of Wires (Not Shown) M R M R M R M R M R M R 38 Finish Flange, Inlet Air PVC Trap (Not Shown) R R R R R R Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 10. 8

9 GDD95A DOWNFLOW CONDENSING GAS FURNACE % AFUE ITEM DESCRIPTION 054B4XE 072C5XE 090C5XE 118D5XE 1 Door Set Y Y Y Y 2 Top Panel 2B3562R 2B3563R 2B3563R 2B3564R 3 Burner Assembly Ignitor Assembly - Nitride Igniter Bracket (Not Shown) R R R R 6 Inshot Burner Manifold, Burner Tube Orifice, Main Burner, Natural Gas R R R R 9 Flame Sensor R R R R 10 Gas Valve Roll-Out Switch Control Board Fuse Heat Exchanger Main Air Limit Inducer Motor Inducer Orifice R R R R 18 Inducer Limit Outlet Header Box Pressure Switch (Inducer) R R R Transformer Door Switch R R R R 23 Blower Assembly Blower Housing Assembly R R R R 25 Capacitor Motor, Blower Wheel, Blower R R R R 28 Blower Limit/Blower Deck Limit Repl. Motor Mount Kit In-Line Drain Assembly R R R R 31 Drain Tube, Soft, 23 (Not Shown) Drain Tube, Hard J (Not Shown) R R R R 33 Drain Tube, Soft, J 30 (Not Shown) Tube, Soft, 5.5 (Not Shown) Hose, High Temperature (Not Shown) R R R R 36 Set of Wires (Not Shown) M M M M Finish Flange, Inlet Air Please specify the correct Model No., Serial No, and part number(s) when ordering parts from the nearest authorized dealer or service center. FOR COMPONENT LOCATIONS, SEE PAGE 11. 9

10 GUH92A & GUH95A UPFLOW / HORIZONTAL COMPONENT LOCATION 14 GUH92A Models GUH95A Models

11 GDD92A & GDD95A DOWNFLOW COMPONENT LOCATION GDD92A Models GDD95A Models 11

12 Specifications & illustrations subject to change without notice or incurring obligations (11/13) B (Replaces A)

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13

More information

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16

More information

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM

More information

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES

More information

REPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only. REPAIR PARTS GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace GCVC80603BXBC GCVC80803BXBC GCVC80805CXBC GCVC81005CXBC This manual is to be used by qualified technicians only. 2016 Goodman Manufacturing

More information

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)

TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite 500 REPAIR PARTS GMPN Multi-Positional Gas Furnace GMPN040-3 GMPN060-3 GMPN080-4 GMPN100-4 GMPN120-5 nufacturing Company, L.P. San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to be

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS

TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

Installation Instructions

Installation Instructions Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

GV Series 4 Section Assembly

GV Series 4 Section Assembly GV Series 4 Section Assembly 192 Current Service Parts GV Series 4 Section Assembly Fig. No. Part No. Description Size Notes 1 322-200-280 Section Assembly, GV-3 (Repair Kit Required) 3 1 322-200-281 Section

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX2B060A9362A, TUX2B080A922A, TUX2C100A982A, TUX2D1A9602A, TDX2B060A9362A, TDX2B080A922A, TDX2C100A982A,

More information

Propane & Gas Heating

Propane & Gas Heating Propane & Gas Heating High Efficiency Furnaces CHX/CDX, CHB/CDB Series Built Tough for Lifetime Comfort Built for Your Comfort Thermo Products, makers of Thermo Pride heating and cooling equipment, listens

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel

More information

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh *High Efficiency and Flexibility Designed to Meet the Needs of New Homes

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

Installation Instructions

Installation Instructions Condensing Heat Exchanger Kit Cancels: IIK 8A-- IIK 8A--7 -- Installation Instructions Part No. 171-7 through -7 NOTE: Read the entire instruction before starting the installation. INTRODUCTION This instruction

More information

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh HEATING & COOLING Product Data 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh 4-way Multipoise Design Allows More Applications...

More information

Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts.

Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts. NEOTHERM Boilers and Water Heaters Page 77 Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts. 12.1 General Information To order or purchase parts for the LAARS NeoTherm, contact your

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

REPLACEMENT PARTS LIST O4 Series Oil Furnace

REPLACEMENT PARTS LIST O4 Series Oil Furnace R REPLACEMENT PARTS LIST O4 Series Oil Furnace Low Boy High Boy Downflow/Horizontal shown with optional front vestibule Model O4HD 2 Model O4HD Horizontal Oil Furnaces O4HD O4HD ITEM DESCRIPTION 091A-12F

More information

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number from data plate on

More information

MASTERTEMP HEATER REPLACEMENT PARTS

MASTERTEMP HEATER REPLACEMENT PARTS 0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available

More information

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* TM 59TP5A Performance Boost Two---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59TP5A Two -stage Multipoise Performance Boost Condensing Gas Furnace features two

More information

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING 2015 Lennox Industries Inc. Dallas, Texas, USA 506443-01 01/2015 Supersedes 08/2012 SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can

More information

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. CONDENSING GAS FURNACE Owner s Manual NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based

More information

/13 Price - $5.00

/13 Price - $5.00 INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR ALPINE CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT WATER BOILER 9700609 As an ENERGY STAR Partner, U.S. Boiler Company has determined that

More information

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING 2012 Lennox Industries Inc. Dallas, Texas, USA 506737-01 12/2012 Supersedes 06/2011 EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUDA00A92B, TUDA00A930B, TUDA060A92B, TUDA060A936B, TUDB060A936B, TUDB080A92B, TUDB080A936B, TUDB080A98B, TUDC080A960B,

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

EL296UHV SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING 2011 Lennox Industries Inc. Dallas, Texas, USA 506769 01 08/2012 Supersedes 10/2011 EL296UHV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property

More information

Installation Instructions

Installation Instructions Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before

More information

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* 59TN6A InfinityR Two---Stage, Variable Speed 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59TN6A Multipoise Variable-Speed Condensing Gas Furnace features the two -stage

More information

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Models BWBBAN00005 BWBBAN000070 BWBBAN00006 BWBBAN0000 BWBBAN0005 BWBBAN00070 BWBBAN0005 BWBBAN0005 BWBBAN0005 Ordering Instructions

More information

MLG35 Parts Manual Phase 8

MLG35 Parts Manual Phase 8 MLG35 Parts Manual Phase 8 For Internal Use Only RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Whirlpool Corporation Commercial Laundry Benton Harbor, MI 49022 1-800-662-3587 Part No.

More information

EL195UH SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* TM 59SP5A Performance Boost, Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59SP5A Multipoise Performance Boost Condensing Gas Furnace features SEER -boosting

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 060 November 07 Supersedes August 05 MODEL NUMBER IDENTIFICATION SL

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Description Model Weil-McLain part number. Vent Termination Kit for 3 Stainless Steel All Replacement parts Figure 96 Miscellaneous parts Description Model Weil-McLain part number Vent Termination Kit for 3" PVC All 383-500-397 Vent Termination Kit for 3" Stainless Steel All 382-200-430 Vent

More information

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9X2B040U2PSAA S9X2B040U3PSAA S9X2B060U3PSAA S9X2B060U4PSAA

More information

15B Cast Iron Gas Fired Boilers For Forced Hot Water

15B Cast Iron Gas Fired Boilers For Forced Hot Water Models 5B05FE 5B070FE 5B0FE 5B0FE 5B5FE 5B70FE 5B5FE 5B5FE 5B5FE 5B Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest

More information

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. CONDENSING GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

More information

Ultra Boiler Series 1 & 2 Jacket Parts

Ultra Boiler Series 1 & 2 Jacket Parts GAS Ultra Boiler Series 1 & 2 Jacket Parts 9 10 8 6 7 1 5 2 3 Fig. Part Description Model Mfr. 1 383-500-135 Jacket Front Door 595-000-000 595-000-001 595-000-002 595-000-003 Panel Door Jacket Plastic

More information

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 4 --- WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier s QuieTecht

More information

40 Residential Gas Furnace Operation

40 Residential Gas Furnace Operation 40 Residential Gas Furnace Operation Model Evolution/Nomenclature Heating Sequence of Operation Schematics Ignition Systems Service/Troubleshooting American Standard Inc. 999 Preface Air Conditioning and

More information

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA UH2P-SF-1B Gas Furnace Direct Vent Condensing Two Stage Heat Models: * - First letter may be A or T *UH2B060A936VA *UH2B080A942VA *UH2C100A948VA *UH2D120A960VA *DH2B060A936VA *DH2B080A942VA *DH2C100A948VA

More information

Product Data STANDARD FEATURES

Product Data STANDARD FEATURES PERFORMANCE 80 TWO---STAGE VARIABLE --- SPEED 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Series 100 Product Data A10249 THE PERFORMANCE 80 GAS FURNACE

More information

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace Series 121 Input Capacities: 4, thru 12, Btuh U L T R A H I G H E F F I C I E N C Y G A S F U R N A N C E Variable capacity,

More information

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Models BWBAAN0000 BWBAAN000070 BWBAAN0000 BWBAAN0000 BWBAAN000 BWBAAN00070 BWBAAN000 BWBAAN000 BWBAAN000 Ordering Instructions

More information

USER S INFORMATION MANUAL SLP98UHV SERIES

USER S INFORMATION MANUAL SLP98UHV SERIES 2017 Lennox Industries Inc. Dallas, Texas, USA 506443-01 04/2017 Supersedes 10/2015 USER S INFORMATION MANUAL SLP98UHV SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration,

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace GAS URNACE User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas urnace NOTE: This manual must be left with the equipment user. MODEL GB1AAV UPLOW URNACE WARNING: If

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDDA00A92A, TDDA060A92A, TDDA060A936A, TDDB060A936A, TDDB080A936A, TDDB080A95A TDDB00A95A, TDDC00A98A, TDDC00A95A TDDCA95A,

More information

355MAV Sizes 040 thru 120 Series E

355MAV Sizes 040 thru 120 Series E DELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Sizes 040 thru 120 Series E HIGH EFFICIENCY GAS FURNACE VARIABLE CAPACITY SYSTEM THE INTELLIGENT ING MACHINE Building

More information

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies

More information

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Cased Aluminum Coils Dedicated Upflow / Downflow Convertible to horizontal with separately purchased kit 18-AD32D1-3 Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit Upflow models: 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA 4PXCBU36BS3HAA

More information

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces Gas Furnaces Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces R98V- Series 98% A.F.U.E. Input Rates from 60 to 115 kbtu [11.57 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

G61MPV SERIES GAS FURNACE WARNING

G61MPV SERIES GAS FURNACE WARNING 2003 Lennox Industries Inc. Dallas, Texas, USA 504,809M 03/2009 Supersedes 06/2003 G61MPV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER

More information

Roll Heated Flatwork Finisher

Roll Heated Flatwork Finisher Roll Heated Flatwork Finisher 20 Inch (500 mm) Roll Heated Models Refer to Page 3 for Model Numbers Parts FWF1N_1300577 www.alliancelaundry.com Part No. 1300577R14 January 2018 Table of Contents Title

More information

Installation Instructions

Installation Instructions Heat Exchanger Cell Replacement Kit Cancels: IIK 373L-35-14 IIK 373L-35-17 3-97 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.

More information

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE MULTIPOISE, CONDENSING 8MCA, 8MVP, 8MXA HEATING & COOLING USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE

More information

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G22-473 REV. 3 Supersedes Form No. G22-473 Rev. 2 GAS FURNACES UGPL- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR [15 to 37 kw] (U.S. & Canadian Models) Annual Fuel

More information

GHR26. Service Literature GHR26 SERIES UNITS DOWN FLOW POSITION HORIZONTAL POSITION

GHR26. Service Literature GHR26 SERIES UNITS DOWN FLOW POSITION HORIZONTAL POSITION Service Literature GHR26 Corp. 9722 L11 Revised 07/2001 GHR26 SERIES UNITS GHR26 series units are high efficiency horizontal or down flow gas furnaces manufactured with Lennox DuralokPlus aluminized and

More information

Product Data. 926TA PREFERREDt TWO -STAGE 4 -WAY MULTIPOISE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A

Product Data. 926TA PREFERREDt TWO -STAGE 4 -WAY MULTIPOISE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A PREFERREDt TWO -STAGE 4 -WAY MULTIPOISE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A A11264 The Multipoise Variable-Speed Condensing Gas Furnace features the two -stage Preferredt Series System. The

More information

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CLA Low-Boy Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CLA combines high efficiency and quiet operation with oil heating

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort

More information

T9MPV SmartComfort VS90 Product Specifications

T9MPV SmartComfort VS90 Product Specifications 90+ Variable Speed Two -Stage Heating Furnace FLEXIBILITY Supports two--stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40 high with wider cabinets, for ease of installation

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET DS-07 COMPRESSORS 1 1 Compressor, H20J403DBLA 015-03652-001 2 - - 1 1 Compressor, H20J403DBEA 015-03682-001-2 - 1 1 Compressor,

More information

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-503 REV. 1 Supersedes Form No. G11-503 GAS FURNACES Visit www.rheem.com for complete details. RGRC- SERIES Model with Input Rates from 45,000 to 105,000 BTU/HR [13.19 to 30.77 kw] (All Models

More information

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A Product Data A11264 The Multipoise SEER Boost Condensing Gas Furnace features the single -stage Preferred System. The Boost

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace TDD-D- XB 80 TUEA00A92A, TUEA060A92A, TUEA060A936A TUEB060A936A, TUEB080A936A, TUEB080A98A TUEB00A936A, TUEC00A98A, TUEC00A960A

More information

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation

More information

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated, affordable home that is a smart choice

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/

More information

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-450 REV. 13 Supersedes Form No. G11-450 Rev. 12 GAS FURNACES /RGRB- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND FORM NO. G11-500 REV. 1 Supersedes Form No. G11-500 GAS FURNACES RGGE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (U.S. & Canadian Models) Equipped with Comfort Control

More information

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration CONDENSING GAS FURNACE Product Data A11300 The model is an efficient and robust 4 way multipoise condensing furnace with features including singlestage heating and a rugged PSC blower motor. The builds

More information