1 SCREW PLUG IMMERSION HEATERS ELECTRIC PROCESS HEATER SOLUTIONS BEGIN HERE... Electric heaters are our only business. We are specialists in designing, engineering, and manufacturing both standard and custom Electric Process Heaters. WARREN ELECTRIC CORPORATION 36 Franklin Street, PO Box 86, USA Toll Free: HEAT (4328) Tel: Fax: ASME ACCREDITED
2 ELECTRIC PROCESS HEATER SOLUTIONS BEGIN HERE! Warren Electric Corporation has over 40 years of experience in the design and manufacture of high-quality electric process heaters. This knowledge is put to work to provide long-lasting and trouble-free immersion heaters. We welcome and appreciate the opportunity to assist you with selecting, quoting, and supplying your electric heater requirements. You will appreciate: A wide selection of standard and custom screw plug, flanged, circulation, and over-the-side electric immersion heaters from a large parts inventory. Prompt quotations and detailed order acknowledgements. Reliable shipping schedule performance. Ease of expediting as our inventory and shipping schedules are monitored continuously by computer. High Quality Products at competitive pricing. Custom designs from standard parts. Replacements for most brands of electric immersion heaters. Prompt and individual attention to your particular heater needs. A 15 month warranty period. Terminal enclosures available in many different types for all applications including standard heavy-duty terminal enclosures to protect integral thermostats and electrical connections from hazards. The Quality Policy at Warren Electric Corporation, throughout the organization, is to meet or exceed the expectations of our customers, satisfy our obligations to the standards for which we are accredited, and to continously strive for excellence. STANDARD OR CUSTOM HEATERS. QUALITY HEATERS FOR TROUBLE- FREE OPERATION. Quality Commitment Warren Electric Corporation heaters must pass vigourous inspections prior to shipment. Each indivudual heating element is checked for electrical leakage and breakdown at high voltage before assembly. All heaters are 100% hydrostatically pressure tested to insure braze or weld attaching the element to the screw plug is free of all leaks. We also electrically test 100% of heaters to ensure they meet the wattage/voltgage specifications of the order. 100% of our heaters are also subject to testing for moisture content and hipot testing. Every heater that Warren Electric Corporation has ever manufactured is identified with a serial number prior to shipment. These serial numbers are kept on file indefinetly and can be used to identify back to the original inspection sheet and purchase order. Third party certifications and inspections, as described on the back cover of this catalog, inlcuding UL and ISO, and over 40 years of manufacturing excellence makes Warren Electric Corporation the quality manufacturer and supplier of choice for QUALITY ELECTRIC IMMERSION HEATERS. WHAT YOU NEED. WHEN YOU NEED IT. HELP FROM PEOPLE WHO KNOW HEATERS INSIDE AND OUT. How to Order, PLEASE: Call the HEAT SOURCE Hot Line: HEAT (4328) Toll Free Fax Us: Us: wec@warrenonline.com Download a WEC Quick Quote form at Online Fill out a Quick Quote Online Page 2
3 SCREW PLUG HEATER CATALOG TABLE OF CONTENTS Introduction About WEC Page 2 Table of Contents Page 3 About Screw Plug Heaters Pages 4-6 Screw Plug Immersion Heaters Misc. Copper Sheathed Elements Pages 7-9 1" and 1¼" NPT Page 7 2" NPT Page 8 2½" NPT Page 9 3" NPT Page 9 Steel Sheathed Elements WSI Pages " NPT Page 10 2½" and 3" NPT - Page 11 Steel Sheathed Elements WSI Pages " NPT Page 12 2½" and 3" NPT - Page 13 Steel Sheathed Elements WSI Pages " and 1¼" NPT Page 14 2" NPT Pages 15 2½" and 3" NPT Page 16 Incoloy Sheathed Elements WSI Pages " NPT Page 17 2½" and 3" NPT - Page 18 Incoloy Sheathed Elements WSI Pages " and 1¼" NPT Page 19 2" NPT Page 20 2½" and 3" NPT Page 21 Incoloy Sheathed Elements WSI Pages " NPT Page 22 2½" and 3" NPT - Page 23 Stainless Steel Sheathed Elements WSI Pages " NPT Page 24 2½" and 3" NPT - Page 25 Thermostat/Thermowell Information... Page 26 Thermocouples, RTD s... Page 26 Casings... Page 27 Terminal Enclosures... Pages Model Designation... Page 30 Screw Plug Heater Quick Quote... Page 31 Certifications and Compliances... Back Cover Whether it be STANDARD or CUSTOM, a REPLACEMENT or NEW DESIGN... please turn to us for COMPETITIVE PRICING and QUICK DELIVERY on your next Electric Heater application. Page 3
4 Screw Plug Immersion Heaters Standard Features Warren Electric Corporation has been manufacturing QUALITY Industrial Screw Plug Electric Heaters since WEC Screw Plug Heaters consist of tubular elements that are brazed or welded to a screw plug and provided with or without Thermostat, and with Terminal Enclosures suited for your application. Screw Plug sizes up to 3" NPT in Brass, Bronze, Carbon, and Stainless Steels are available. Screw Plug Heaters are screwed directly into a tank wall or through a matching pipe coupling. Terminal Enclosures are either general purpose, weather and/or explosion resistant. The selection of terminal enclosure should be determined by the most extreme operating environment at the heater terminal area. For more information, please turn to pages in this catalog. Most heaters listed in this catalog are available with or without Thermostats, Thermocouples, and/or RTD s. Information is located on page 26 of this catalog or consult factory. We are dedicated to meeting and exceeding the needs and expectations of our customers for INNOVATIVE and RELIABLE heating solutions. Screw Plug Heater Specifications: Wattage: 0.25 to 100 kilowatts Voltage: Up to 600 volts, Single or 3 phase Screw plug size: 1" to 3" NPT Pressure rating: Up to 300 PSIG Screw Plug Material: Carbon Steel, Various Stainless Steels, Brass, Bronze Immersed length: Up to 130 inches Sheath Materials: Steel, Copper, Stainless Steel(s), and Incoloy Our Applications Engineers and Technical Sales people are available to assist you. Please call our toll free Heat Source Hotline HEAT (4328) or us. Features/Options that are available in the manufacture of WEC Screw Plug Heaters include: Element Sheath Materials Passivation or Electropolishing Screw Plug Materials High-Temperature Applications Welded or Brazed Construction Thermostats, Thermocouples, RTD s, etc... Temperature Control Options UL listing Terminal Enclosures ASME Certification Element Supports and Baffles CE Conformance for Export Compact Designs Immersion lengths to meet your WSI requirements Multiple Circuits Casings & Assemblies with options of your choice Thermowell standard Ground lug standard to insure NEC requirements Page 4
5 Screw Plug Immersion Heaters Applications Typical applications for Screw Plug Heaters include, but are not limited to, process water heating, freeze protection, and the heating of oils, and heat transfer mediums. Warren Electric Corporation Screw Plug Immersion Heaters are used to heat: Water: Clean, Potable, Industrial water rinse tanks Deionized, Process, Vapor degreasers Demineralized Degreasing solutions Oils: Asphalt, Fuels, Cooking, Air and gas flow Heat Transfer, Crude, Caustic solutions Hydraulic Chemical baths Lubricating oils at API specified Anti-freeze (glycol) solutions watt densities Paraffin or wax Mild acids Electroplating Freeze Protection...and more! Heater Selection Heater selection determination includes a lot of factors including: 1. Final temperature desired. 2. Medium being heated, all specifications including corrosiveness, heat density. 3. Watt Density allowed. 4. Sheath Material required. 5. Screw Plug Material required. 6. Power Requirements. 7. Heater environment for Terminal Enclosure determination. 8. Maximum length and/or size restrictions. For assistance on your heater selection and/or power requirements, please refer to our Screw Plug Quick Quote Form on the back inside cover of this catalog or call our technical staff for assistance. Typical Installation The heated portion of the heater elements must remain completely immersed and completely flooded whenever energized. The cold section of the heater should be extended completely into the fluid being heated. The heater may overheat, damage the elements, tank, or fluid being heated, and/or create a possible safey hazard due to high sheath temperatures. Elements Tubular heating elements are constructed using only the highest quality component materials. The outer metal sheath material used is determined by the specific application. Warren Electric Corporation uses only high purity magnesium oxide insulation to insure good dielectric resistance between the resistance wire and the outer metal sheath. The internal nichrome resistance wire is carefully selected and coiled to meet stringent design criteria based upon individual heater specifications. The resistance wire is coiled and then welded to a terminal pin to assure positive connection. The coil is then centered in the metal sheath and insulated with the highest quality magnesium oxide which is then highly compacted and acts as an electrical insulator. The elements are bent in a U-bend configuration and the U-bends are repressed to remove air gaps which ensure good dieletric strength. Each individual heating element is checked for electrical leakage and breakdown at high voltage before assembly. Standard sheath materials available are: Copper, Steel, Stainless 321, Stainless 316L, and Incoloy 840. Sheath selection is determined by the user s knowledge of the chemical composition of the medium being heated, corrosiveness, contaminants, and controls. Page 5
6 Screw Plug Immersion Heaters 1" NPT Plug 1¼" NPT Plug Thermostats/RTD Models listed on these pages are available with or without thermostats, (various temperature ranges), thermocouples, or RTD s. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. For detailed information, please refer to Thermostats, Thermocouples, & RTD s on page 26. 2" NPT Plug 2½" NPT Plug Terminal Enclosures Heavy duty general purpose terminal enclosures are standard with Warren Electric Corporation Screw Plug Heaters. Warren Electric s general purpose terminal enclosure provides superior mechanical protection for your heater s wiring, terminals, and thermostat. Our general purpose terminal enclosure is constructed from heavy gauge cast aluminum, as opposed to a drawn tin can style often seen with other brands. 3" NPT Plug Specifications and dimensions are subject to change. Consult Factory. Models listed in this catalog are without thermostats and have low profile terminal enclosures, but all models listed on these pages are available with various terminal enclosures including Economy, General Purpose, Weather and/or Explosion- Resistant. For dimensional and information on other terminal enclosures, see Terminal Enclosures section on pages Page 6
7 Screw Plug Heaters - Copper Sheathed Elements Typical Applications for Copper Sheathed Elements Clean Water Freeze Protection of Aqueous Solutions Other Aqueous Solutions not corrosive to Copper Sheath. 1" NPT BRASS Plug 0.5 to W/in 2 U.L. Listed 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (140) 55 (8.5) XFS C XFS C XFS C 1 3 (2) (172) 63 (9.8) XFS C XFS C XFS C 1 3 (2) (172) 84 (13) XFS C XFS C XFS C 1 3 (2) (242) 88 (13.6) XFS C XFS C XFS C 1 3 (2) (318) 86 (13.3) XFS C XFS C XFS C 1 3 (2) (381) 89 (13.8) XFS C XFS C XFS C 1 3 (2) 3 17 (432) 93 (14.4) XFS C XFS C XFS C 1 3 (2) 4 21 (534) 99 (15.3) XFS C XFS C XFS C 1 4 (2) 1¼" NPT BRASS Plug 0.5 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. U.L. Listed 120, 208, 240, & 480 Volt, Single Phase Immersion Watt Density 120V 208V 240V 480V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase 1 Phase Ele lb (kg) (140) 55 (8.5) XGS C XGS C XGS C 1 3 (2) (166) 63 (9.8) XGS C XGS C XGS C 1 3 (2) (140) 55 (8.5) XGS C XGS C XGS C 2 3 (2) (166) 68 (10.5) XGS C XGS C XGS C XGS C 2 4 (2) (166) 84 (13) XGS C XGS C XGS C XGS C 2 4 (2) (267) 65 (10.1) XGS C XGS C XGS C XGS C 2 4 (2) (242) 88 (13.6) XGS C XGS C XGS C XGS C 2 4 (2) 3 12 (305) 68 (10.5) XGS C XGS C XGS C XGS C 2 4 (2) (318) 86 (13.3) XGS C XGS C XGS C XGS C 2 4 (2) 4 15 (381) 70 (10.9) XGS C XGS C XGS C XGS C 2 5 (3) 5 15 (381) 89 (13.8) XGS C XGS C XGS C XGS C 2 4 (2) (470) 70 (10.9) XGS C XGS C XGS C XGS C 2 5 (3) 6 17 (432) 93 (14.4) XGS C XGS C XGS C XGS C 2 5 (3) 6 21 (534) 74 (11.5) XGS C XGS C XGS C XGS C 2 5 (3) Copper Sheathed Elements Page 7
8 Screw Plug Heaters - Copper Sheathed Elements 2" NPT BRONZE Plug U.L. Listed 1.5 to W/in 120 Volt, Single Phase (280) 61 (9.5) XPS C XPS C 1 4 (2) 2 8 (204) 61 (9.5) XPS-2-1-8C XPS C 2 4 (2) (242) 58 (9) XPS C XPS C 2 5 (3) 3 8 (204) 61 (9.5) XPS-3-1-8C XPS C XPS C*3 3 5 (3) 3 11 (280) 61 (9.5) XPS C XPS C 2 5 (3) 4 15 (381) 56 (8.7) XPS C XPS C 2 5 (3) (280) 61 (9.5) XPS C XPS C XPS C*3 3 5 (3) 5 18 (458) 57 (8.8) XPS C XPS C 2 5 (3) 6 15 (381) 56 (8.7) XPS C XPS C*3 3 6 (3) 6 21 (534) 58 (9) XPS C 2 6 (3) 7 25 (635) 60 (9.3) XPS C 2 6 (3) (458) 57 (8.8) XPS C XPS C*3 3 6 (3) 8 27 (686) 61 (9.5) XPS C 2 6 (3) 9 21 (534) 58 (9) XPS C XPS C*3 3 7 (4) (813) 61 (9.5) XPS C 2 7 (4) (686) 61 (9.5) XPS C*3 3 8 (4) (813) 61 (9.5) XPS C*3 3 9 (5) (280) 61 (9.5) XPS C XPS C 1 4 (2) 2 8 (204) 61 (9.5) XPS-2-2-8C XPS-2-4-8C 2 4 (2) (242) 58 (9) XPS C XPS C 2 5 (3) 3 8 (204) 61 (9.5) XPS-3-2-8C XPS-3-2-8C*3 XPS-3-4-8C XPS-3-4-8C*3 3 5 (3) 3 11 (280) 61 (9.5) XPS C XPS C 2 5 (3) 4 15 (381) 56 (8.7) XPS C XPS C 2 5 (3) (280) 61 (9.5) XPS C XPS C*3 XPS C XPS C*3 3 5 (3) 5 18 (458) 57 (8.8) XPS C XPS C 2 5 (3) 6 15 (381) 56 (8.7) XPS C XPS C*3 XPS C XPS C*3 3 6 (3) 6 21 (534) 58 (9) XPS C XPS C 2 6 (3) 7 25 (635) 60 (9.3) XPS C XPS C 2 6 (3) (458) 57 (8.8) XPS C XPS C*3 XPS C XPS C*3 3 6 (3) 8 27 (686) 61 (9.5) XPS C XPS C 2 6 (3) 9 21 (534) 58 (9) XPS C XPS C*3 XPS C XPS C*3 3 7 (4) (813) 61 (9.5) XPS C XPS C 2 7 (4) (686) 61 (9.5) XPS C*3 XPS C XPS C*3 3 8 (4) (966) 67 (10.4) XPS C+2 XPS C 2 7 (4) (813) 61 (9.5) XPS C*3 XPS C XPS C*3 3 9 (5) (966) 67 (10.4) XPS C*3 XPS C XPS C*3 3 9 (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 8
9 WARRE ARREN EL EC T RIC CO RP POR ATION Screw Plug Heaters - Copper Sheathed Elements 2½" NPT BRONZE Plug 3 to W/in (204) 61 (9.5) XRS-3-1-8C XRS C XRS C*3 3 5 (3) (280) 61 (9.5) XRS C XRS C XRS C*3 3 6 (3) 6 15 (381) 56 (8.7) XRS C XRS C*3 3 6 (3) (458) 57 (8.8) XRS C XRS C*3 3 7 (4) 9 21 (534) 58 (9) XRS C XRS C*3 3 7 (4) (686) 61 (9.5) XRS C*3 3 8 (4) (813) 61 (9.5) XRS C*3 3 9 (5) 3 8 (204) 61 (9.5) XRS-3-2-8C XRS-3-2-8C*3 XRS-3-4-8C XRS-3-4-8C*3 3 5 (3) (280) 61 (9.5) XRS C XRS C*3 XRS C XRS C*3 3 6 (3) 6 15 (381) 56 (8.7) XRS C XRS C*3 XRS C XRS C*3 3 6 (3) (458) 57 (8.8) XRS C XRS C*3 XRS C XRS C*3 3 7 (4) 9 21 (534) 58 (9) XRS C XRS C*3 XRS C XRS C*3 3 7 (4) (686) 61 (9.5) XRS C*3 XRS C XRS C*3 3 8 (4) (813) 61 (9.5) XRS C*3 XRS C XRS C*3 3 9 (5) (966) 67 (10.4) XRS C*3 XRS C XRS C* (5) 3" NPT STEEL Plug 6 to W/in 2 U.L. Listed 120 Volt, Single Phase U.L. Listed 120 Volt, Single Phase 6 8 (204) 61 (9.5) XCS-6-1-8C+2 XCS C XCS C* (5) 9 11 (280) 61 (9.5) XCS C+2 XCS C XCS C* (5) (381) 56 (8.7) XCS C+2 XCS C* (6) (458) 57 (8.8) XCS C+2 XCS C* (6) (534) 58 (9) XCS C+2 XCS C* (7) (661) 61 (9.5) XCS C* (7) (813) 61 (9.5) XCS C* (8) 6 8 (204) 61 (9.5) XCS-6-2-8C XCS-6-2-8C*3 XCS-6-4-8C XCS-6-4-8C* (5) 9 11 (280) 61 (9.5) XCS C XCS C*3 XCS C XCS C* (5) (381) 56 (8.7) XCS C XCS C*3 XCS C XCS C* (6) (458) 57 (8.8) XCS C+2 XCS C*3 XCS C XCS C* (6) (534) 58 (9) XCS C+2 XCS C*3 XCS C XCS C* (7) (661) 61 (9.5) XCS C+2 XCS C*3+2 XCS C+2 XCS C* (7) (813) 61 (9.5) XCS C*3+2 XCS C+2 XCS C* (8) (966) 67 (10.4) XCS C*3+2 XCS C+2 XCS C* (9) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 9 Copper Sheathed Elements
10 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements 6-11 WSI Residual Fuel Oils (Bunker C and #6) Asphalt Heavy Weight Lubrication Oils Static Heat Transfer Oils Hydraulic Fluids The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 2" NPT STEEL Plug 0.5 to 5 Low Watt Density 6-11 WSI 6-11 W/in Volt, Single Phase (305) 9 (1.4) XPS XPS (3) (305) 6 (0.9) XPS *3 3 6 (3) 1 18 (458) 8 (1.2) XPS XPS XPS *3 3 7 (4) (712) 9 (1.4) XPS XPS (4) (508) 10 (1.6) XPS XPS *3 3 7 (4) 2 28 (712) 9 (1.4) XPS XPS *3 3 8 (4) (762) 11 (1.7) XPS XPS *3 3 9 (5) 3 38 (966) 10 (1.6) XPS XPS * (5) 4 54 (1372) 9 (1.4) XPS XPS * (5) (305) 9 (1.4) XPS XPS (3) (305) 6 (0.9) XPS *3 XPS *3 3 6 (3) 1 18 (458) 8 (1.2) XPS XPS *3 XPS XPS *3 3 7 (4) (712) 9 (1.4) XPS XPS (4) (508) 10 (1.6) XPS XPS *3 XPS XPS *3 3 7 (4) 2 28 (712) 9 (1.4) XPS XPS *3 XPS XPS *3 3 8 (4) (762) 11 (1.7) XPS XPS *3 XPS XPS *3 3 9 (5) 3 38 (966) 10 (1.6) XPS XPS *3 XPS XPS * (5) 4 51 (1296) 9 (1.4) XPS XPS *3 XPS XPS * (5) 5 63 (1601) 10 (1.6) XPS XPS *3 XPS XPS * (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 10
11 Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug 0.5 to 5 Low Watt Density 6-11 WSI 6-11 W/in Volt, Single Phase (305) 6 (0.9) XRS XRS *3 3 7 (4) (305) 9 (1.4) XRS XRS XRS *3 3 7 (4) 1 18 (458) 8 (1.2) XRS XRS *3 3 8 (4) (508) 10 (1.6) XRS XRS *3 3 8 (4) 2 28 (712) 9 (1.4) XRS XRS *3 3 9 (5) (762) 11 (1.7) XRS XRS * (5) 3 38 (966) 10 (1.6) XRS XRS * (5) 4 54 (1372) 9 (1.4) XRS XRS * (6) (305) 6 (0.9) XRS XRS *3 XRS XRS *3 3 7 (4) (305) 9 (1.4) XRS XRS *3 XRS XRS *3 3 7 (4) 1 18 (458) 8 (1.2) XRS XRS *3 XRS XRS *3 3 8 (4) (508) 10 (1.6) XRS XRS *3 XRS XRS *3 3 8 (4) 2 28 (712) 9 (1.4) XRS XRS *3 XRS XRS *3 3 9 (5) (762) 11 (1.7) XRS XRS *3 XRS XRS * (5) 3 38 (966) 10 (1.6) XRS XRS *3 XRS XRS * (5) 4 51 (1296) 9 (1.4) XRS XRS *3 XRS XRS * (6) 5 63 (1601) 10 (1.6) XRS XRS *3 XRS XRS * (7) Steel Sheathed Elements WSI 3" NPT STEEL Plug 1.5 to W/in Volt, Single Phase (293) 9 (1.4) XCS XCS XCS * (5) 2 17 (432) 8 (1.2) XCS XCS XCS * (6) 3 20 (508) 10 (1.6) XCS XCS * (6) 4 28 (712) 9 (1.4) XCS XCS * (8) 5 30 (762) 11 (1.7) XCS XCS * (8) 6 38 (966) 10 (1.6) XCS XCS * (9) 8 54 (1372) 9 (1.4) XCS XCS * (11) (1677) 9 (1.4) XCS XCS * (13) (1982) 10 (1.6) XCS * (15) (293) 9 (1.4) XCS XCS *3 XCS (5) 2 17 (432) 8 (1.2) XCS XCS *3 XCS XCS * (6) 3 20 (508) 10 (1.6) XCS XCS *3 XCS XCS * (6) 4 28 (712) 9 (1.4) XCS XCS *3 XCS XCS * (8) 5 30 (762) 11 (1.7) XCS XCS *3 XCS XCS * (8) 6 38 (966) 10 (1.6) XCS XCS *3 XCS XCS * (9) 8 54 (1372) 9 (1.4) XCS XCS *3 XCS XCS * (11) (1677) 9 (1.4) XCS XCS *3 XCS XCS * (13) (1982) 10 (1.6) XCS XCS *3 XCS XCS * (15) Page 11
12 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements WSI Hydraulic Fluid Applications Medium Weight Oils Liquid Paraffin #4 and #5 Fuel Oils Heat Transfer Fluids 2" NPT STEEL Plug The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 1.5 to W/in Volt, Single Phase (331) 16 (2.5) XPS XPS XPS *3 3 6 (3) 2 25 (635) 16 (2.5) XPS XPS (4) (813) 16 (2.5) XPS XPS (4) 3 25 (635) 16 (2.5) XPS XPS XPS *3 3 8 (4) (1016) 16 (2.5) XPS XPS (4) 4 48 (1220) 16 (2.5) XPS (5) 4 32 (813) 16 (2.5) XPS XPS *3 3 9 (5) 5 57 (1448) 17 (2.6) XPS (5) 5 40 (1016) 16 (2.5) XPS XPS * (5) 6 68 (1728) 17 (2.6) XPS (5) 6 48 (1220) 16 (2.5) XPS XPS * (5) (1448) 17 (2.6) XPS XPS * (6) 9 68 (1728) 17 (2.6) XPS XPS * (7) (331) 16 (2.5) XPS XPS *3 XPS XPS *3 3 6 (3) 2 25 (635) 16 (2.5) XPS XPS (4) (813) 16 (2.5) XPS XPS (4) 3 25 (635) 16 (2.5) XPS XPS *3 XPS XPS *3 3 8 (4) (1016) 16 (2.5) XPS XPS (4) 4 48 (1220) 16 (2.5) XPS XPS (5) 4 32 (813) 16 (2.5) XPS XPS *3 XPS XPS *3 3 9 (5) 5 57 (1448) 17 (2.6) XPS XPS (5) 5 40 (1016) 16 (2.5) XPS XPS *3 XPS XPS * (5) 6 68 (1728) 17 (2.6) XPS XPS (5) 6 48 (1220) 16 (2.5) XPS XPS *3 XPS XPS * (5) (1448) 17 (2.6) XPS XPS *3 XPS XPS * (6) 9 68 (1728) 17 (2.6) XPS XPS *3 XPS XPS * (7) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 12
13 WARREN ELECTRIC CORPORATION War arren, en, Rho hode e Islan and Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug Watt Density WSI 120 Volt, Single Phase (331) 16 (2.5) XRS XRS XRS *3 3 7 (4) 2 17 (432) 16 (2.5) XRS XRS XRS *3 3 8 (4) (508) 17 (2.6) XRS XRS XRS *3 3 8 (4) 3 25 (635) 16 (2.5) XRS XRS XRS *3 3 9 (5) 4 32 (813) 16 (2.5) XRS XRS * (5) 5 40 (1016) 16 (2.5) XRS XRS * (5) 6 48 (1220) 16 (2.5) XRS XRS * (6) (331) 16 (2.5) XRS XRS *3 XRS XRS *3 3 5 (3) 2 17 (432) 16 (2.5) XRS XRS *3 XRS XRS *3 3 5 (3) (508) 17 (2.6) XRS XRS *3 XRS XRS *3 3 5 (3) 3 25 (635) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 4 32 (813) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 5 40 (1016) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 6 48 (1220) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) (1448) 17 (2.6) XRS XRS *3 XRS XRS *3 3 7 (4) 9 68 (1728) 17 (2.6) XRS XRS *3 XRS XRS *3 3 7 (4) 3" NPT STEEL Plug 1.5 to W/in 2 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 13 (331) 16 (2.5) XCS XCS XCS * (5) 4 17 (432) 16 (2.5) XCS XCS XCS * (6) 5 20 (508) 17 (2.6) XCS XCS XCS * (6) 6 25 (635) 16 (2.5) XCS XCS XCS * (7) 8 32 (813) 16 (2.5) XCS XCS * (8) (1016) 16 (2.5) XCS XCS * (9) (1220) 16 (2.5) XCS XCS * (10) 3 13 (331) 16 (2.5) XCS XCS *3 XCS XCS * (5) 4 17 (432) 16 (2.5) XCS XCS *3 XCS XCS * (6) 5 20 (508) 17 (2.6) XCS XCS *3 XCS XCS * (6) 6 25 (635) 16 (2.5) XCS XCS *3 XCS XCS * (7) 8 32 (813) 16 (2.5) XCS XCS *3 XCS XCS * (8) (1016) 16 (2.5) XCS XCS *3 XCS XCS * (9) (1220) 16 (2.5) XCS XCS *3 XCS XCS * (10) (1448) 17 (2.6) XCS XCS *3 XCS XCS * (11) (1728) 17 (2.6) XCS XCS *3 XCS XCS * (13) Page 13 Steel Sheathed Elements WSI
14 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements WSI Degreasing Solutions Mineral Oils Light Lubrication Oils Flowing Hydraulic Fluids Flowing HeatTransfer Fluids The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 1" NPT STEEL Plug Watt Density 23 WSI 0.25 to W/in 2 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (166) 23 (3.6) XFS (2) (242) 23 (3.6) XFS XFS XFS (2) (305) 23 (3.6) XFS XFS XFS (2) (458) 23 (3.6) XFS XFS XFS (2) 1 23 (585) 23 (3.6) XFS XFS XFS (2) (864) 23 (3.6) XFS XFS XFS (2) 1¼" NPT STEEL Plug 0.5 to 3 Watt Density 23 WSI 23 W/in 2 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (166) 23 (3.6) XGS XGS XGS (2) (242) 23 (3.6) XGS XGS XGS (2) 1 12 (305) 23 (3.6) XGS XGS XGS (2) (458) 23 (3.6) XGS XGS XGS (3) 2 23 (585) 23 (3.6) XGS XGS XGS (3) 3 34 (864) 23 (3.6) XGS XGS XGS (4) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 14
15 Screw Plug Heaters - Steel Sheathed Elements 2" NPT STEEL Plug 2" NPT STEEL Plug 1.5 to 12.5 Watt Density WSI W/in Volt, Single Phase (305) 27 (4.2) XPS XPS (3) 2 18 (458) 24 (3.7) XPS XPS (3) (508) 25 (3.9) XPS XPS (3) 3 25 (635) 24 (3.7) XPS XPS (4) 3 18 (458) 24 (3.7) XPS XPS XPS *3 3 7 (4) (826) 24 (3.7) XPS XPS (4) (635) 24 (3.7) XPS XPS XPS *3 3 8 (4) (1207) 24 (3.7) XPS (5) (826) 24 (3.7) XPS XPS *3 3 9 (5) (1016) 24 (3.7) XPS XPS * (5) (1207) 24 (3.7) XPS XPS * (5) (1626) 24 (3.7) XPS * (7) 1.5 to 12.5 Watt Density WSI W/in (305) 27 (4.2) XPS XPS (3) 2 18 (458) 24 (3.7) XPS XPS (3) (508) 25 (3.9) XPS XPS (3) 3 25 (635) 24 (3.7) XPS XPS (4) 3 18 (458) 24 (3.7) XPS XPS *3 XPS XPS *3 3 7 (4) (826) 24 (3.7) XPS XPS (4) (635) 24 (3.7) XPS XPS *3 XPS XPS *3 3 8 (4) 5 40 (1016) 24 (3.7) XPS XPS (4) (1207) 24 (3.7) XPS XPS (5) (826) 24 (3.7) XPS XPS *3 XPS XPS *3 3 9 (5) (1016) 24 (3.7) XPS XPS *3 XPS XPS * (5) (1207) 24 (3.7) XPS XPS *3 XPS XPS * (5) (1626) 24 (3.7) XPS XPS *3 XPS XPS * (7) Steel Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 15
16 Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug 3" NPT STEEL Plug 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 18 (458) 24 (3.7) XRS XRS XRS *3 3 8 (4) (635) 24 (3.7) XRS XRS XRS *3 3 9 (5) (826) 24 (3.7) XRS XRS * (5) (1016) 24 (3.7) XRS XRS * (5) (1207) 24 (3.7) XRS XRS * (6) (1626) 24 (3.7) XRS * (7) 3 18 (458) 24 (3.7) XRS XRS *3 XRS XRS *3 3 8 (4) (635) 24 (3.7) XRS XRS *3 XRS XRS *3 3 9 (5) (826) 24 (3.7) XRS XRS *3 XRS XRS * (5) (1016) 24 (3.7) XRS XRS *3 XRS XRS * (5) (1207) 24 (3.7) XRS XRS *3 XRS XRS * (6) (1626) 24 (3.7) XRS *3 XRS XRS * (7) (1931) 25 (3.9) XRS *3 XRS XRS * (8) 6 to 30 Watt Density WSI W/in Volt, Single & Three Phase Immersion Watt Density 208V 208V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 3 Phase Ele lb (kg) 6 18 (458) 24 (3.7) XCS XCS * (6) 9 25 (635) 24 (3.7) XCS XCS * (7) (826) 24 (3.7) XCS * (8) (1016) 24 (3.7) XCS * (9) 6 18 (458) 24 (3.7) XCS XCS *3 XCS XCS * (6) 9 25 (635) 24 (3.7) XCS XCS *3 XCS XCS * (7) (826) 24 (3.7) XCS XCS *3 XCS XCS * (8) (1016) 24 (3.7) XCS XCS *3 XCS XCS * (9) (1207) 24 (3.7) XCS XCS *3 XCS XCS * (10) (1626) 24 (3.7) XCS *3+2 XCS XCS * (12) (1931) 25 (3.9) XCS *3+2 XCS XCS * (14) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 16
17 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Citric-Based Fluids Flowing Steam and many Highlky Corrosive Chemical Solutions 2" NPT S.S. Plug The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 2 to W/in Volt, Single Phase 2 25 (635) 16 (2.5) XPS IC XPS IC 2 7 (4) 3 25 (635) 16 (2.5) XPS IC XPS IC XPS IC*3 3 8 (4) (1016) 16 (2.5) XPS IC XPS IC 2 8 (4) 4 48 (1220) 16 (2.5) XPS IC XPS IC 2 9 (5) 5 56 (1423) 17 (2.6) XPS IC XPS IC 2 10 (5) 5 40 (1016) 16 (2.5) XPS IC XPS IC XPS IC* (5) 6 67 (1702) 17 (2.6) XPS IC 2 11 (5) 6 48 (1220) 16 (2.5) XPS IC XPS IC* (5) (1423) 17 (2.6) XPS IC XPS IC* (6) 9 67 (1702) 17 (2.6) XPS IC XPS IC* (7) 2 25 (635) 16 (2.5) XPS IC XPS IC 2 7 (4) 3 25 (635) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) (1016) 16 (2.5) XPS IC XPS IC 2 8 (4) 4 48 (1220) 16 (2.5) XPS IC XPS IC 2 9 (5) 5 56 (1423) 17 (2.6) XPS IC XPS IC 2 10 (5) 5 40 (1016) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC* (5) 6 67 (1702) 17 (2.6) XPS IC XPS IC 2 11 (5) 6 48 (1220) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC* (5) (1423) 17 (2.6) XPS IC XPS IC*3 XPS IC XPS IC* (6) 9 67 (1702) 17 (2.6) XPS IC XPS IC*3 XPS IC XPS IC* (7) Incoloy Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 17
18 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to 9 Watt Density WSI W/in Volt, Single Phase 3 25 (635) 16 (2.5) XRS IC XRS IC XRS IC*3 3 9 (5) 4 32 (813) 16 (2.5) XRS IC XRS IC XRS IC* (5) 5 40 (1016) 16 (2.5) XRS IC XRS IC* (5) 6 48 (1220) 16 (2.5) XRS IC XRS IC* (6) (1423) 17 (2.6) XRS IC XRS IC* (7) 9 67 (1702) 17 (2.6) XRS IC XRS IC* (8) 3 25 (635) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) 4 32 (813) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (5) 5 40 (1016) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (5) 6 48 (1220) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (6) (1423) 17 (2.6) XRS IC XRS IC*3 XRS IC XRS IC* (7) 9 67 (1702) 17 (2.6) XRS IC XRS IC*3 XRS IC XRS IC* (8) 3" NPT S.S. Plug 6 to 18 Watt Density WSI W/in Volt, Single Phase 6 25 (635) 16 (2.5) XCS IC+2 XCS IC XCS IC* (7) 8 32 (813) 16 (2.5) XCS IC+2 XCS IC XCS IC* (8) (1016) 16 (2.5) XCS IC XCS IC* (10) (1220) 16 (2.5) XCS IC+2 XCS IC* (10) (1423) 17 (2.6) XCS IC+2 XCS IC* (12) (1702) 17 (2.6) XCS IC+2 XCS IC* (13) 6 25 (635) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (7) 8 32 (813) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (8) (1016) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (10) (1220) 16 (2.5) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1423) 17 (2.6) XCS IC+2 XCS IC*3 XCS IC XCS IC* (12) (1702) 17 (2.6) XCS IC+2 XCS IC*3 XCS IC XCS IC* (13) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 18
19 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Forced Air & Gases Vegetable Oils Ethylene Glycol Causic Solutions and many Mildly Corrosive Chemical Solutions 1" NPT S.S. Plug Watt Density WSI to W/in 2 Immersion Watt Density 120V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase Ele lb (kg) (242) 22 (3.4) XFS IC XFS IC 1 3 (2) (305) 23 (3.6) XFS IC XFS IC 1 3 (2) (458) 22 (3.4) XFS IC XFS IC 1 4 (2) 1 23 (585) 23 (3.6) XFS IC XFS IC 1 4 (2) 1¼" NPT S.S. Plug 0.75 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 120 & 240 Volt, Single Phase 120 & 240 Volt, Single Phase Incoloy Sheathed Elements WSI Immersion Watt Density 120V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase Ele lb (kg) (242) 22 (3.4) XGS IC XGS IC 2 4 (2) 1 12 (305) 23 (3.6) XGS IC XGS IC 2 4 (2) (458) 22 (3.4) XGS IC XGS IC 2 5 (3) 2 23 (585) 23 (3.6) XGS IC XGS IC 2 5 (3) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 19
20 Screw Plug Heaters - Incoloy Sheathed Elements 2" NPT S.S. Plug 2 to 15 Watt Density WSI W/in Volt, Single Phase 18 (458) 23 (3.6) XPS IC XPS IC 2 6 (3) 25 (635) 24 (3.7) XPS IC-Y XPS IC-Y 2 7 (4) 18 (458) 24 (3.7) XPS IC XPS IC XPS IC*3 3 7 (4) 33 (839) 24 (3.7) XPS IC XPS IC 2 7 (4) 25 (635) 24 (3.7) XPS IC XPS IC XPS IC*3 3 8 (4) 40 (1016) 24 (3.7) XPS IC XPS IC 2 8 (4) 48 (1220) 24 (3.7) XPS IC 2 9 (5) 33 (839) 24 (3.7) XPS IC XPS IC*3 3 9 (5) 40 (1016) 24 (3.7) XPS IC XPS IC* (5) 48 (1220) 24 (3.7) XPS IC XPS IC* (5) 64 (1626) 24 (3.7) XPS IC* (7) 2 18 (458) 23 (3.6) XPS IC XPS IC 2 6 (3) 3 25 (635) 24 (3.7) XPS IC XPS IC 2 7 (4) 3 18 (458) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) 4 33 (839) 24 (3.7) XPS IC XPS IC 2 7 (4) (635) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) 5 40 (1016) 24 (3.7) XPS IC XPS IC 2 8 (4) 6 48 (1220) 24 (3.7) XPS IC XPS IC 2 9 (5) 6 33 (839) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 9 (5) (1016) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC* (5) 9 48 (1220) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC* (5) (1626) 24 (3.7) XPS IC*3 XPS IC XPS IC* (7) (2007) 24 (3.7) XPS IC*3 XPS IC XPS IC* (8) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 20
21 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 18 (458) 23 (3.6) XRS IC XRS IC XRS IC*3 3 8 (4) (635) 24 (3.7) XRS IC XRS IC XRS IC*3 3 9 (5) 6 33 (839) 24 (3.7) XRS IC XRS IC* (5) (1016) 24 (3.7) XRS IC XRS IC* (5) 9 48 (1220) 24 (3.7) XRS IC XRS IC* (6) (1626) 24 (3.7) XRS IC* (7) 3 18 (458) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) (635) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) 6 33 (839) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (5) (1016) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (5) 9 48 (1220) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (6) (1626) 24 (3.7) XRS IC*3 XRS IC XRS IC* (7) (2007) 24 (3.7) XRS IC*3 XRS IC XRS IC* (8) 3" NPT S.S. Plug 6 to 30 Watt Density WSI W/in Volt, Single Phase 6 18 (458) 23 (3.6) XCS IC+2 XCS IC XCS IC* (6) 9 25 (635) 24 (3.7) XCS IC+2 XCS IC XCS IC* (7) (839) 24 (3.7) XCS IC+2 XCS IC* (8) (1016) 24 (3.7) XCS IC+2 XCS IC* (10) (1220) 24 (3.7) XCS IC+2 XCS IC* (10) 6 18 (458) 23 (3.6) XCS IC XCS IC*3 XCS IC XCS IC* (6) 9 25 (635) 24 (3.7) XCS IC XCS IC*3 XCS IC XCS IC* (7) (839) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (8) (1016) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1220) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1626) 24 (3.7) XCS IC*3+2 XCS IC+2 XCS IC* (13) (2007) 24 (3.7) XCS IC*3+2 XCS IC+2 XCS IC* (15) Incoloy Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 21
22 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Process Water Deionized Water (Passivated) Potable Water 2" NPT S.S. Plug 2 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 120 Volt, Single Phase 2 9 (229) 51 (7.9) XPS-2-1-9IC XPS IC 2 5 (3) 3 13 (331) 49 (7.6) XPS IC XPS IC 2 5 (3) 3 9 (229) 51 (7.9) XPS-3-1-9IC XPS IC XPS IC*3 3 6 (3) (445) 47 (7.3) XPS IC XPS IC 2 6 (3) (331) 49 (7.6) XPS IC XPS IC XPS IC*3 3 6 (3) 5 20 (508) 51 (7.9) XPS IC XPS IC 2 6 (3) 6 25 (635) 48 (7.4) XPS IC 2 7 (4) (445) 47 (7.3) XPS IC XPS IC*3 3 7 (4) (508) 51 (7.9) XPS IC XPS IC*3 3 7 (4) 8 32 (813) 49 (7.6) XPS IC 2 7 (4) 9 25 (635) 48 (7.4) XPS IC XPS IC*3 3 8 (4) (813) 49 (7.6) XPS IC*3 3 9 (5) (1016) 48 (7.4) XPS IC* (5) 2 9 (229) 51 (7.9) XPS-2-2-9IC XPS-2-4-9IC 2 5 (3) 3 13 (331) 49 (7.6) XPS IC XPS IC 2 5 (3) 3 9 (229) 51 (7.9) XPS-3-2-9IC XPS-3-2-9IC*3 XPS-3-4-9IC XPS-3-4-9IC*3 3 6 (3) (445) 47 (7.3) XPS IC XPS IC 2 6 (3) (331) 49 (7.6) XPS IC XPS IC*3 XPS IC XPS IC*3 3 6 (3) 5 20 (508) 51 (7.9) XPS IC XPS IC 2 6 (3) 6 25 (635) 48 (7.4) XPS IC XPS IC 2 7 (4) (445) 47 (7.3) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) (508) 51 (7.9) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) 8 32 (813) 49 (7.6) XPS IC XPS IC 2 7 (4) 9 25 (635) 48 (7.4) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) (1016) 48 (7.4) XPS IC XPS IC 2 8 (4) (1220) 48 (7.4) XPS IC 2 9 (5) (813) 49 (7.6) XPS IC*3 XPS IC XPS IC*3 3 9 (5) (1016) 48 (7.4) XPS IC*3 XPS IC XPS IC* (5) (1220) 48 (7.4) XPS IC*3 XPS IC XPS IC* (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 22
23 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to 18 Watt Density WSI W/in Volt, Single Phase 3 9 (229) 51 (7.9) XRS-3-1-9IC XRS IC XRS IC*3 3 7 (4) (331) 49 (7.6) XRS IC XRS IC XRS IC*3 3 7 (4) (445) 47 (7.3) XRS IC XRS IC*3 3 8 (4) (508) 51 (7.9) XRS IC XRS IC*3 3 8 (4) 9 25 (635) 48 (7.4) XRS IC XRS IC*3 3 9 (5) (813) 49 (7.6) XRS IC* (5) (1016) 48 (7.4) XRS IC* (5) 3 9 (229) 51 (7.9) XRS-3-2-9IC XRS-3-2-9IC*3 XRS-3-4-9IC XRS-3-4-9IC*3 3 7 (4) (331) 49 (7.6) XRS IC XRS IC*3 XRS IC XRS IC*3 3 7 (4) (445) 47 (7.3) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) (508) 51 (7.9) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) 9 25 (635) 48 (7.4) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) (813) 49 (7.6) XRS IC*3 XRS IC XRS IC* (5) (1016) 48 (7.4) XRS IC*3 XRS IC XRS IC* (5) (1220) 48 (7.4) XRS IC*3 XRS IC XRS IC* (6) 3" NPT S.S. Plug 6 to 36 Watt Density WSI W/in Volt, Single Phase 6 9 (229) 51 (7.9) XCS-6-1-9IC+2 XCS IC XCS IC* (5) 9 13 (331) 49 (7.6) XCS IC+2 XCS IC XCS IC* (5) (445) 47 (7.3) XCS IC+2 XCS IC* (6) (508) 51 (7.9) XCS IC+2 XCS IC* (7) (635) 48 (7.4) XCS IC+2 XCS IC* (7) (813) 49 (7.6) XCS IC* (8) (1016) 48 (7.4) XCS IC* (10) 6 9 (229) 55 (8.5) XCS-6-2-9IC XCS-6-2-9IC*3 XCS-6-4-9IC XCS-6-4-9IC* (5) 9 13 (331) 52 (8.1) XCS IC XCS IC*3 XCS IC XCS IC* (5) (445) 47 (7.3) XCS IC+2 XCS IC*3 XCS IC XCS IC* (6) (508) 50 (7.8) XCS IC+2 XCS IC*3 XCS IC XCS IC* (7) (635) 47 (7.3) XCS IC+2 XCS IC*3 XCS IC XCS IC* (7) (813) 49 (7.6) XCS IC*3+2 XCS IC+2 XCS IC* (8) (1016) 48 (7.4) XCS IC*3+2 XCS IC+2 XCS IC* (10) 36For models 48 (1220) or options 48 not (7.4) listed, please refer to our XCS IC*3+2 Quick Quote XCS IC+2 on the back inside XCS IC*3 cover or consult 6factory. 22 (10) Page 23 Incoloy Sheathed Elements WSI
24 Screw Plug Heaters - Stainless Sheathed Elements Typical Applications for Stainless Sheathed Elements WSI Deionized Water (Passivated) Mild Alkaline Solutions 2" NPT S.S. Plug 2 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 120 Volt, Single Phase Immersion Watt Density 120V 208V 208V No. in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 3 Phase Ele 2 9 (229) 51 (7.9) XPS-2-1-9SS XPS SS (331) 49 (7.6) XPS SS XPS SS (229) 51 (7.9) XPS-3-1-9SS XPS SS XPS SS* (445) 47 (7.3) XPS SS XPS SS (331) 49 (7.6) XPS SS XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS (635) 48 (7.4) XPS SS (445) 47 (7.3) XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS* (813) 49 (7.6) XPS SS (635) 48 (7.4) XPS SS XPS SS* (813) 49 (7.6) XPS SS* (1016) 48 (7.4) XPS SS* V 240V 480V 480V No. in (mm) W/in 2 (W/cm 2 ) 1 Phase 3 Phase 1 Phase 3 Phase Ele 2 9 (229) 51 (7.9) XPS-2-2-9SS XPS-2-4-9SS (331) 49 (7.6) XPS SS XPS SS (229) 51 (7.9) XPS-3-2-9SS XPS-3-2-9SS*3 XPS-3-4-9SS XPS-3-4-9SS* (445) 47 (7.3) XPS SS XPS SS (331) 49 (7.6) XPS SS XPS SS*3 XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS (635) 48 (7.4) XPS SS XPS SS (445) 47 (7.3) XPS SS XPS SS*3 XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS*3 XPS SS XPS SS* (813) 49 (7.6) XPS SS XPS SS (635) 48 (7.4) XPS SS XPS SS*3 XPS SS XPS SS* (1016) 48 (7.4) XPS SS XPS SS (1220) 48 (7.4) XPS SS (813) 49 (7.6) XPS SS*3 XPS SS XPS SS* (1016) 48 (7.4) XPS SS*3 XPS SS XPS SS* (1220) 48 (7.4) XPS SS*3 XPS SS XPS SS*3 3 For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Immersion Watt Density Page 24
25 Screw Plug Heaters - Stainless Sheathed Elements 2½" NPT S.S. Plug 3 to 18 Watt Density WSI W/in Volt, Single Phase 3 9 (229) 51 (7.9) XRS-3-1-9SS XRS SS XRS SS*3 3 7 (4) (331) 49 (7.6) XRS SS XRS SS XRS SS*3 3 7 (4) (445) 47 (7.3) XRS SS XRS SS*3 3 8 (4) (508) 51 (7.9) XRS SS XRS SS*3 3 8 (4) 9 25 (635) 48 (7.4) XRS SS XRS SS*3 3 9 (5) (813) 49 (7.6) XRS SS* (5) (1016) 48 (7.4) XRS SS* (5) 3 9 (229) 51 (7.9) XRS-3-2-9SS XRS-3-2-9SS*3 XRS-3-4-9SS XRS-3-4-9SS*3 3 7 (4) (331) 49 (7.6) XRS SS XRS SS*3 XRS SS XRS SS*3 3 7 (4) (445) 47 (7.3) XRS SS XRS SS*3 XRS SS XRS SS*3 3 8 (4) (508) 51 (7.9) XRS SS XRS SS*3 XRS SS XRS SS*3 3 8 (4) 9 25 (635) 48 (7.4) XRS SS XRS SS*3 XRS SS XRS SS*3 3 9 (5) (813) 49 (7.6) XRS SS*3 XRS SS XRS SS* (5) (1016) 48 (7.4) XRS SS*3 XRS SS XRS SS* (5) (1220) 48 (7.4) XRS SS*3 XRS SS XRS SS* (6) 3" NPT S.S. Plug 6 to 30 Watt Density WSI W/in Volt, Single Phase 6 9 (229) 51 (7.9) XCS-6-1-9SS+2 XCS SS XCS SS* (5) 9 13 (331) 49 (7.6) XCS SS+2 XCS SS XCS SS* (5) (445) 47 (7.3) XCS SS+2 XCS SS* (6) (508) 51 (7.9) XCS SS+2 XCS SS* (7) (635) 48 (7.4) XCS SS+2 XCS SS* (7) (813) 49 (7.6) XCS SS* (8) (1016) 48 (7.4) XCS SS* (10) 6 9 (229) 51 (7.9) XCS-6-2-9SS XCS-6-2-9SS*3 XCS-6-4-9SS XCS-6-4-9SS* (5) 9 13 (331) 49 (7.6) XCS SS XCS SS*3 XCS SS XCS SS* (5) (445) 47 (7.3) XCS SS+2 XCS SS*3 XCS SS XCS SS* (6) (508) 51 (7.9) XCS SS+2 XCS SS*3 XCS SS XCS SS* (7) (635) 48 (7.4) XCS SS+2 XCS SS*3 XCS SS XCS SS* (7) (813) 49 (7.6) XCS SS*3+2 XCS SS+2 XCS SS* (8) (1016) 48 (7.4) XCS SS*3+2 XCS SS+2 XCS SS* (10) (1220) 48 (7.4) XCS SS*3+2 XCS SS+2 XCS SS* (10) Page 25 Stainl ainless s She heathe hed Element ements s WSI
26 Thermostat/Thermowell Information A specific wiring instruction sheet is provided with each heater. All heaters listed in this catalog are shown without thermostats, but do have integral thermowells. All heaters without thermostats and/or thermocouples are provided with low profile terminal enclosures unless otherwise requested. However, all heaters are available with our standard SPST Thermostats. Other ranges and DPST thermostats are also available. Please advise factory of your request. Remote mount thermostats with thermowells also are available, as well as manual reset cutouts, thermocouples, pilot lights, and RTD s. Specify enclosure type, minimum capillary length, and thermowell material and length when ordering. Please consult our Applications Engineers for further information. Please note: Thermostats are not a fail safe device. Users should install To Add Thermostat: adequate controls or safety devices to control failure. Replace existing prefix X in our model number and add prefix: 1- for F range F Range SPST Thermostat ( C) 2- for F range F Range SPST Thermostat ( C) 3- for F range F Range SPST Thermostat ( C) For exmaple Thermocouples For applications that require a more accurate temperature sensing device than a thermostat, a built in thermocouple such as Type J or K can be provided. A thermocouple only senses temperature and must be used in conjunction with a controller (provided by another source). A thermocouple can be purchased with either a grounded or ungrounded junction and you need to inform us which type you need for your controller. Warren Electric uses the ungrounded type thermocouples as a standard. When using a thermocouple you need to have a separate conduit opening for the thermocouple wires. The Type J thermocouples are conductors of iron and constantan with a maximum operating temperature of 1400 F (normally used for applications up to 800 F). It is normally used in liquid applications. The Type K thermocouples are conductors of alumel and chromel with a maximum operating temperature of 2300 F (normally used for applications over 800 F). It is normally used in gas applications To Add Thermocouple RTD S 1-GS C is a model with a SPST thermostat with F range Replace existing prefix X and add prefix 5- for Thermocouple For example: 5-GS C is a model with a thermocouple To Add RTD For even more accurate temperature sensing than a thermocouple, a RTD is recommended. RTD s are available with two, Replace existing prefix X and add prefix three and four wires for different types of applications. For 7- for RTD further information, feel free to contact our Application Engineers. e.g. 7-GS C is a model with a RTD An integral thermostat, if provided, is designed for temperature control service only. A thermostat is not fail safe. It should not be used for temperature limiting duty. The system designer is responsible to install adequate back-up controls and safety devices. Where the consequences of failure could result in bodily or property injury, back-up controls are essential. Page 26
27 Casings & Assemblies Standard and custom design casings are available for all screw plug models. All casings can be manufactured with virtually any type and size of inlet, outlet, drain, and/or vent to suit your application. Pressure ratings for casings for screw plug heaters from 150 to 1500 PSIG (including ASME certification) are available. High temperature insulation and jacketing are also available for all casing models as requested. Please submit details to our Applications Engineer for quote. Max. Heater Imm. Length (in.) 2" NPT Casings 2-1/2" NPT Casings 3" NPT Casings Casing Model Number "A" (in.) Max. Heater Imm. Length (in.) Casing Model Number Max. Heater Imm. Length (in.) Casing Model Number 6 SP-S-6 7 1/2 6 SP-R SP-C SP-S-8 9 1/2 8 SP-R SP-C SP-S /2 10 SP-R SP-C SP-S /2 12 SP-R SP-C SP-S /2 14 SP-R SP-C SP-S /2 16 SP-R SP-C SP-S /2 18 SP-R SP-C SP-S /2 20 SP-R SP-C SP-S /2 22 SP-R SP-C SP-S /2 24 SP-R SP-C SP-S /2 26 SP-R SP-C SP-S /2 28 SP-R SP-C SP-S /2 30 SP-R SP-C SP-S /2 32 SP-R SP-C SP-S /2 34 SP-R SP-C SP-S /2 36 SP-R SP-C SP-S /2 38 SP-R SP-C SP-S /2 40 SP-R SP-C SP-S /2 42 SP-R SP-C SP-S /2 44 SP-R SP-C SP-S /2 46 SP-R SP-C SP-S /2 48 SP-R SP-C SP-S /2 50 SP-R SP-C SP-S /2 52 SP-R SP-C SP-S /2 54 SP-R SP-C SP-S /2 56 SP-R SP-C SP-S /2 58 SP-R SP-C SP-S /2 60 SP-R SP-C SP-S /2 62 SP-R SP-C SP-S /2 64 SP-R SP-C SP-S /2 66 SP-R SP-C SP-S /2 68 SP-R SP-C SP-S /2 70 SP-R SP-C SP-S /2 72 SP-R SP-C SP-S /2 74 SP-R SP-C SP-S /2 76 SP-R SP-C SP-S /2 78 SP-R SP-C SP-S /2 80 SP-R SP-C "A" (in.) "A" (in.) Insulated and Jacketed Casing Assemblies All Warren Electric casings are available insulated and jacketed for high temperature applications where process heat losses are to be kept at a minimum. Casings are furnished with calcium silicate insulation and steel jackets. Page 27
Immersion Heaters. Screw Plug Immersion Heater
Screw plug immersion heaters are ideal for direct immersion heating of liquids, including all types of oils and heat transfer solutions. Available in a variety of sizes, screw plug immersion heaters feature
More informationScrew Plug Immersion Heaters
Overview consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. are screwed directly through a threaded opening in
More informationTubular Industrial Process
are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating type heaters, to a pipe. See
More informationC D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product
Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately
More informationDifferences Among Screw Plug Immersion Heaters
PDS QUALITY Differences Among Screw Plug Immersion Heaters On first impression, various manufacturers of screw plug immersion heaters appear to be all alike; but when you take a closer look at screw plug
More informationTubular Industrial Process
Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round
More informationTubular Industrial Process
consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationPipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters
Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationPipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters
Construction Features 1" 2-1/2" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging of hex, thread and riser assures reliability. Element
More informationHow 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?
PDS QUALITY On first impression, various manufacturers of screw plug immersion heaters appear to be all alike; but when you take a closer look at screw plug immersion heaters, it becomes evident that considerable
More informationFlanged Immersion Heaters
Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating
More informationChecklist Selecting the Proper Flanged Heater
are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating type heaters, to a pipe. See
More informationCirculation Heaters. To order, call or shop online at omega.com SM. CHF Series
CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationSTRAIGHT & FORMED TUBULAR HEATERS
STRAIGHT & FORMED TUBULAR HEATERS Applications: FORMING MACHINES HEATING MOLDS & PLATENS IMMERSION INTO LIQUIDS RADIANT & CONVECTION HEATING EMBEDDED OR CAST INTO METAL Tubular heaters are the main heating
More informationFlange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX
Heaters - CX Heaters CX Application heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating
More informationScrew plug immersion heaters
Screw plug HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE The screw plug by CETAL are designed and manufactured as a standard range or according to customer specifications. Reliability
More information( )
(1-800-492-8826) FANGE HEATERS OVERVIEW WATTCO flange heaters are made using hairpin or bugle type tubular elements using incoloy sheathed elements that are welded or silver-brazed into a pipe or steel
More informationThermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.
DH & DHT Series ir Duct Heaters 5-300 kw 240 and 480 Volt, Three Phase (Up to 600V vailable) DH Typical Installation DHT Typical Installation INCOLOY Sheath Elements 800 F Max. Outlet ir Temp. (DH) 1200
More information( )
(1-800-492-8826) OVERVIEW WATTCO over-the-side are made of sidemounted tubular elements. Perfectly designed for freeze protection, for heating viscous solutions, water, oils, solvents, salts, and acids.
More informationStrip/Clamp-On Heaters
Max. Operating Typical Max. Temperatures Watt Densities Strip/Clamp-On Heaters Sheath Materials F C W/in 2 W/cm 2 Page Mineral Insulated (MI) 304 stainless steel 1400 760 140 21.7 477 375 High-Temperature
More informationOVER-THE-SIDE HEATERS. immersion heaters
OVER-THE-SIDE HEATERS OVERVIEW WATTCO over-the-side are made of sidemounted tubular elements. Perfectly designed for freeze protection, for heating viscous solutions, water, oils, solvents, salts, and
More informationSCREWPLUG HEATERS. immersion heaters
SCREWPLUG HETERS SCREWPLUG HETERS OVERVIEW WTTCO screwplug heaters are comprised of hairpin tubular elements that are brazed or welded into a machined pipe thread fitting, which are then screwed directly
More informationFlange Heaters Type CX
pplication Flange heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating element watt density.
More informationPackaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase
Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free
More informationASME Packaged Electric Water Heater
MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long
More informationTypical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating
Process air duct heaters are used for tempering forced air in many industrial processes. Heater wattage is dependent on air outlet temperature (up to 1200 F [650 C]) and air velocity. Smaller duct heaters
More informationCartridge Heaters. Components. Application Guidelines
Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters
More informationCartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data
W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation
More informationELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY
ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS
INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.
More informationTechnical Information
Watt Density & Heater Selection - Guidelines Understanding Watt Density Watt density (W/in ) is the heat flux emanating from each square inch of the effective heating area (heated surface) of the element.
More informationInstallation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018
Installation and Operation Instructions Versa TM Screw Plug Oil & Water Immersion Heater 1 PD449-2 161-306451-003 January 2018 B 6" 1-13/16 Cold (Ref.) 9-1/8" 2-3/4 Min. Hole Size 6" 7-7/8" Thermowell
More informationEHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION
EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55
More informationTubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product
Shown with optional bulkhead fittings Shown with optional mounting flange at end of sheath Design Features Copper brazed steel fins on steel sheath standard. Aluminum based protective coating available.
More informationIndustrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM)
Company Presentation Dipl.-Ing. Wolfgang Vogler (GM) 1 Main Competence is recognised as a professional and competitive company in design and manufacture of electric process heaters and assosiated thyristor
More informationFlange immersion heaters
Flange immersion heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE CETAL flange immersion heaters are designed and manufactured
More informationIndustrial Flanged Immersion Heaters
Industrial Flanged Immersion Heaters Installation, Operation, and Maintenance Instructions 1.0 Handling 1.1 Unpack and handle with care to avoid damage to heater and components. Elements may come in contact
More informationFX5 Series Explosion-Proof Electric Air Heaters
FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial
More informationDesign and Construction Standards SECTION PLUMBING EQUIPMENT
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES
More information10-14 SECTION TUBULAR HEATERS
Tubular Heater Specifications...10-2 Tubular Heater Terminations...10-4 Tubular Heater Mounting...10-5 Tubular Heater Moisture Seals...10-7 Standard Sizes and atings...10-8 Typical Bend Formations...10-10
More informationChromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH
Dimensions (Inches) Rotatable Terminal Cover 1" Conduit Opening Outlet 1" FNPT Inlet 1" FNPT 1" FNPT Pipe Plug (or Inlet) Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION 6" 4" E1 4 (Supersedes
More informationTubular Heaters. Table Of Contents
Table Of Contents Pictorial Index....................... A-24 Tubular Heater Introduction and Specifications..................... 10-2 Tubular Heater Terminations........... 10-4 Tubular Heater Mounting
More informationOPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D
OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:
More informationTubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product
Table Of Contents Pictorial Index....................... A-24 Tubular Heater Introduction and Specifications..................... 10-2 Tubular Heater Terminations........... 10-4 Tubular Heater Mounting
More informationW A T L O W. Straight Resistance Wire. Welded End Cap
W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily
More informationThermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment
Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics
More informationCAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.
CAST-X 1 Circulation Heater With optional built-in controls, CAST-X 1 is a straightforward solution, perfect for OEMs and end users. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X Circulation
More informationIndirect Fired Water Heater
Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite
More informationInstallation, Operation and. Maintenance Instructions
Installation, Operation and Maintenance Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE (Supersedes Ogden Manual 35) JULY, 2004 K Series: Tubular Style Elements Industrial Flanged Immersion
More informationELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY
ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage
More informationW A T L O W. Straight Resistance Wire. Welded End Cap
W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily
More informationSECTION PLUMBING EQUIPMENT
PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT
More informationWATLOW ELECTRIC MANUFACTURING COMPANY
I&M MANUAL No: 316-42-8-1 Page: 1 General Statement The purpose of this product manual (the Manual ) is for Watlow Electric Manufacturing Company ( Watlow ) to convey certain recommendations, advisories,
More informationWATLOW ELECTRIC MANUFACTURING COMPANY
I&M MANUAL No: 316-42-10-1 Page: 1 General Statement The purpose of this product manual (the Manual ) is for Watlow Electric Manufacturing Company ( Watlow ) to convey certain recommendations, advisories,
More informationCirculation Heaters - EX
pplication irculation Heaters - RMOVL LN HTR SKT aloritech circulation heaters are suitable for use in forced flow and natural flow heating loops where a safe, lean, reliable, and efficient heating source
More information! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or
I&M NUMBER: 316-42-10-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationMEGAWAT * HIGH DENSITY CARTRIDGE HEATERS
MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS MEGAWAT high-density cartridges are round tubular heaters with electrical terminations on one side. These dependable heaters are made to withstand tough industrial
More informationUnheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications
Temperatures up to 800 F (982 C) Precise temperature control Choice of lead orientation Built-in type J or K Thermocouple Round, square and rectangular cable Rugged, durable construction MIGHTYBAND The
More informationHotRod CARTRIDGE HEATERS
HotRod CARTRIDGE HEATERS C A R T R I D G E H E A T E R S Same day shipment on 1000 s of models! TODAY HEA T E RS Made in USA ÂÂCONSTRUCTION...3 ÂÂStandard specifications...3 ÂÂWatt Density...4 ÂÂsheath
More informationPackaged Steam Fired Water Heater
MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction
More informationCF1 ProVector Explosion-Proof Heaters
CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations
More informationTubular Heaters and Heating Elements
Tubular Heaters and Heating Elements Tubular Heaters Formed Tubular Heating Elements provide an economical, robust, and versatile heat source. Tubular Heating Elements are commonly used to fit into milled
More informationNuclear Electric Heating
Nuclear Electric Heating Caloritech has exceeded the most demanding nuclear heating requirements for over 30 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear
More informationW A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS
W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS MULTICELL HEATERS......................... UNIQUE ADVANTAGES FOR DEMANDING OPERATIONS Sheath Temperature MULTICELL HEATERS: THE HIGH TEMPERATURE
More informationelectric immersion heaters
C70-7 electric immersion heaters electric heating and controls Table Contents Selection Guide... - Quick Ship Pipe Thread Heaters... - Construction Features... Pipe Thread Heaters... -/ Pipe Thread Heaters...
More informationCartridge Heaters. temperatures up to 450 C. heaters in difficult applications. 2. High impact ceramic cap retards HotRods are available in a wide
HotRod Cartridge Heaters STANDARD The engineers at Marathon Heater have developed a cartridge heater that exceeds the performance and durability of other cartridge HOTROD heaters. Through refinements in
More informationULTRA-SAFE Explosion-proof Duct Heaters
Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer
More informationOPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H
OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SH and H HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659
More information( )
(1-800-492-8826) www.wattco.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types
More information(770) wwww.southgateprocess.com
(770) 345-0010 wwww.southgateprocess.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies
More informationSECTION DOMESTIC WATER HEATERS
SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationCoil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters
Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters Coil Heaters Square, Mini Coil Heaters, Formable/Flexible Tubular Heaters National Plastic Heater, Sensor and Control Inc., is a leading
More informationelectric immersion heaters
C70- electric immersion heaters electric heating and controls Introduction INDEECO designs and manufactures commercial and industrial electric heating and control systems that set the industry standard
More informationFinned Tubular Heaters
Finned Tubular Heaters Finned Tubular Heating Elements Finned Tubular Heaters Finned Tubular Heating Elements are the most versatile, dependable and rugged of any heat generating device. These qualities
More informationCOIL AND CABLE HEATERS. Mightyband Cable Heaters Tempco-Pak Cable Heaters
Mightyband Cable Heaters...5-2 Tempco-Pak Cable Heaters...5-0 Tempco Replacement Heaters for OEM Runnerless Molding Systems...5-4 SECTION COIL AND CABLE HEATERS Design Features Temperatures up to 800 F
More informationTubular Heaters Series
Tubular Heaters Series Immersion Heaters, Tubular Heaters, Ribbed Tubular Heaters Screw-in Immersion Heater Standard sizes for application in water Power (W) 2000 000 4500 6000 7500 Input Voltage (V) 20
More informationWATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationTubular Industrial Process
Tubular Industrial Process Tubular Heater See Page 11-115 Silicone Rubber Heater Cabinet Tempco enclosure heaters are the answer to all your enclosure heater needs. Our heaters are designed to help electric,
More informationSioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers
Sioux EN-Series All-Electric Steam Cleaners and Pressure Washers Sioux EN-Series All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers Model EN-270-H4-3000-XP When Performance and
More informationThe CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater.
CAST-X 25 Circulation Heater The CAST-X 25 is our most compact dual-tube model, a powerful and versatile mid-sized heater. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X heaters are
More informationScrewplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard
Screwplug Heaters Screwplug Heaters pplication Screwplug heaters are primarily used to heat liquids in tanks or vessels. To do so safely and reliably requires that the heating elements remain fully immersed
More informationSNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions
Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationBrasch Hazardous Location Unit Heaters
Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain
More informationDescription. Applications
CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW
More informationC1N & C2N SERIES Fluid heating for light industrial applications
Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationCAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.
CAST-X 2 Circulation Heater CAST-X 2 is a very versatile heater, with multiple housing, standoff, control and enclosure options. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X Circulation
More informationBand Heaters W A T L O W. Special Mica Barrel and Nozzle
W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationMachining: Moderate to Extensive. Pattern Shop
Casting Process: Low Pressure Used for large volume quantities. Specifically suited for intricate and challenging geometric shapes, producing quality castings with consistent dimensional accuracy and superior
More information