SCREW PLUG IMMERSION HEATERS

Size: px
Start display at page:

Download "SCREW PLUG IMMERSION HEATERS"

Transcription

1 SCREW PLUG IMMERSION HEATERS ELECTRIC PROCESS HEATER SOLUTIONS BEGIN HERE... Electric heaters are our only business. We are specialists in designing, engineering, and manufacturing both standard and custom Electric Process Heaters. WARREN ELECTRIC CORPORATION 36 Franklin Street, PO Box 86, USA Toll Free: HEAT (4328) Tel: Fax: ASME ACCREDITED

2 ELECTRIC PROCESS HEATER SOLUTIONS BEGIN HERE! Warren Electric Corporation has over 40 years of experience in the design and manufacture of high-quality electric process heaters. This knowledge is put to work to provide long-lasting and trouble-free immersion heaters. We welcome and appreciate the opportunity to assist you with selecting, quoting, and supplying your electric heater requirements. You will appreciate: A wide selection of standard and custom screw plug, flanged, circulation, and over-the-side electric immersion heaters from a large parts inventory. Prompt quotations and detailed order acknowledgements. Reliable shipping schedule performance. Ease of expediting as our inventory and shipping schedules are monitored continuously by computer. High Quality Products at competitive pricing. Custom designs from standard parts. Replacements for most brands of electric immersion heaters. Prompt and individual attention to your particular heater needs. A 15 month warranty period. Terminal enclosures available in many different types for all applications including standard heavy-duty terminal enclosures to protect integral thermostats and electrical connections from hazards. The Quality Policy at Warren Electric Corporation, throughout the organization, is to meet or exceed the expectations of our customers, satisfy our obligations to the standards for which we are accredited, and to continously strive for excellence. STANDARD OR CUSTOM HEATERS. QUALITY HEATERS FOR TROUBLE- FREE OPERATION. Quality Commitment Warren Electric Corporation heaters must pass vigourous inspections prior to shipment. Each indivudual heating element is checked for electrical leakage and breakdown at high voltage before assembly. All heaters are 100% hydrostatically pressure tested to insure braze or weld attaching the element to the screw plug is free of all leaks. We also electrically test 100% of heaters to ensure they meet the wattage/voltgage specifications of the order. 100% of our heaters are also subject to testing for moisture content and hipot testing. Every heater that Warren Electric Corporation has ever manufactured is identified with a serial number prior to shipment. These serial numbers are kept on file indefinetly and can be used to identify back to the original inspection sheet and purchase order. Third party certifications and inspections, as described on the back cover of this catalog, inlcuding UL and ISO, and over 40 years of manufacturing excellence makes Warren Electric Corporation the quality manufacturer and supplier of choice for QUALITY ELECTRIC IMMERSION HEATERS. WHAT YOU NEED. WHEN YOU NEED IT. HELP FROM PEOPLE WHO KNOW HEATERS INSIDE AND OUT. How to Order, PLEASE: Call the HEAT SOURCE Hot Line: HEAT (4328) Toll Free Fax Us: Us: wec@warrenonline.com Download a WEC Quick Quote form at Online Fill out a Quick Quote Online Page 2

3 SCREW PLUG HEATER CATALOG TABLE OF CONTENTS Introduction About WEC Page 2 Table of Contents Page 3 About Screw Plug Heaters Pages 4-6 Screw Plug Immersion Heaters Misc. Copper Sheathed Elements Pages 7-9 1" and 1¼" NPT Page 7 2" NPT Page 8 2½" NPT Page 9 3" NPT Page 9 Steel Sheathed Elements WSI Pages " NPT Page 10 2½" and 3" NPT - Page 11 Steel Sheathed Elements WSI Pages " NPT Page 12 2½" and 3" NPT - Page 13 Steel Sheathed Elements WSI Pages " and 1¼" NPT Page 14 2" NPT Pages 15 2½" and 3" NPT Page 16 Incoloy Sheathed Elements WSI Pages " NPT Page 17 2½" and 3" NPT - Page 18 Incoloy Sheathed Elements WSI Pages " and 1¼" NPT Page 19 2" NPT Page 20 2½" and 3" NPT Page 21 Incoloy Sheathed Elements WSI Pages " NPT Page 22 2½" and 3" NPT - Page 23 Stainless Steel Sheathed Elements WSI Pages " NPT Page 24 2½" and 3" NPT - Page 25 Thermostat/Thermowell Information... Page 26 Thermocouples, RTD s... Page 26 Casings... Page 27 Terminal Enclosures... Pages Model Designation... Page 30 Screw Plug Heater Quick Quote... Page 31 Certifications and Compliances... Back Cover Whether it be STANDARD or CUSTOM, a REPLACEMENT or NEW DESIGN... please turn to us for COMPETITIVE PRICING and QUICK DELIVERY on your next Electric Heater application. Page 3

4 Screw Plug Immersion Heaters Standard Features Warren Electric Corporation has been manufacturing QUALITY Industrial Screw Plug Electric Heaters since WEC Screw Plug Heaters consist of tubular elements that are brazed or welded to a screw plug and provided with or without Thermostat, and with Terminal Enclosures suited for your application. Screw Plug sizes up to 3" NPT in Brass, Bronze, Carbon, and Stainless Steels are available. Screw Plug Heaters are screwed directly into a tank wall or through a matching pipe coupling. Terminal Enclosures are either general purpose, weather and/or explosion resistant. The selection of terminal enclosure should be determined by the most extreme operating environment at the heater terminal area. For more information, please turn to pages in this catalog. Most heaters listed in this catalog are available with or without Thermostats, Thermocouples, and/or RTD s. Information is located on page 26 of this catalog or consult factory. We are dedicated to meeting and exceeding the needs and expectations of our customers for INNOVATIVE and RELIABLE heating solutions. Screw Plug Heater Specifications: Wattage: 0.25 to 100 kilowatts Voltage: Up to 600 volts, Single or 3 phase Screw plug size: 1" to 3" NPT Pressure rating: Up to 300 PSIG Screw Plug Material: Carbon Steel, Various Stainless Steels, Brass, Bronze Immersed length: Up to 130 inches Sheath Materials: Steel, Copper, Stainless Steel(s), and Incoloy Our Applications Engineers and Technical Sales people are available to assist you. Please call our toll free Heat Source Hotline HEAT (4328) or us. Features/Options that are available in the manufacture of WEC Screw Plug Heaters include: Element Sheath Materials Passivation or Electropolishing Screw Plug Materials High-Temperature Applications Welded or Brazed Construction Thermostats, Thermocouples, RTD s, etc... Temperature Control Options UL listing Terminal Enclosures ASME Certification Element Supports and Baffles CE Conformance for Export Compact Designs Immersion lengths to meet your WSI requirements Multiple Circuits Casings & Assemblies with options of your choice Thermowell standard Ground lug standard to insure NEC requirements Page 4

5 Screw Plug Immersion Heaters Applications Typical applications for Screw Plug Heaters include, but are not limited to, process water heating, freeze protection, and the heating of oils, and heat transfer mediums. Warren Electric Corporation Screw Plug Immersion Heaters are used to heat: Water: Clean, Potable, Industrial water rinse tanks Deionized, Process, Vapor degreasers Demineralized Degreasing solutions Oils: Asphalt, Fuels, Cooking, Air and gas flow Heat Transfer, Crude, Caustic solutions Hydraulic Chemical baths Lubricating oils at API specified Anti-freeze (glycol) solutions watt densities Paraffin or wax Mild acids Electroplating Freeze Protection...and more! Heater Selection Heater selection determination includes a lot of factors including: 1. Final temperature desired. 2. Medium being heated, all specifications including corrosiveness, heat density. 3. Watt Density allowed. 4. Sheath Material required. 5. Screw Plug Material required. 6. Power Requirements. 7. Heater environment for Terminal Enclosure determination. 8. Maximum length and/or size restrictions. For assistance on your heater selection and/or power requirements, please refer to our Screw Plug Quick Quote Form on the back inside cover of this catalog or call our technical staff for assistance. Typical Installation The heated portion of the heater elements must remain completely immersed and completely flooded whenever energized. The cold section of the heater should be extended completely into the fluid being heated. The heater may overheat, damage the elements, tank, or fluid being heated, and/or create a possible safey hazard due to high sheath temperatures. Elements Tubular heating elements are constructed using only the highest quality component materials. The outer metal sheath material used is determined by the specific application. Warren Electric Corporation uses only high purity magnesium oxide insulation to insure good dielectric resistance between the resistance wire and the outer metal sheath. The internal nichrome resistance wire is carefully selected and coiled to meet stringent design criteria based upon individual heater specifications. The resistance wire is coiled and then welded to a terminal pin to assure positive connection. The coil is then centered in the metal sheath and insulated with the highest quality magnesium oxide which is then highly compacted and acts as an electrical insulator. The elements are bent in a U-bend configuration and the U-bends are repressed to remove air gaps which ensure good dieletric strength. Each individual heating element is checked for electrical leakage and breakdown at high voltage before assembly. Standard sheath materials available are: Copper, Steel, Stainless 321, Stainless 316L, and Incoloy 840. Sheath selection is determined by the user s knowledge of the chemical composition of the medium being heated, corrosiveness, contaminants, and controls. Page 5

6 Screw Plug Immersion Heaters 1" NPT Plug 1¼" NPT Plug Thermostats/RTD Models listed on these pages are available with or without thermostats, (various temperature ranges), thermocouples, or RTD s. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. For detailed information, please refer to Thermostats, Thermocouples, & RTD s on page 26. 2" NPT Plug 2½" NPT Plug Terminal Enclosures Heavy duty general purpose terminal enclosures are standard with Warren Electric Corporation Screw Plug Heaters. Warren Electric s general purpose terminal enclosure provides superior mechanical protection for your heater s wiring, terminals, and thermostat. Our general purpose terminal enclosure is constructed from heavy gauge cast aluminum, as opposed to a drawn tin can style often seen with other brands. 3" NPT Plug Specifications and dimensions are subject to change. Consult Factory. Models listed in this catalog are without thermostats and have low profile terminal enclosures, but all models listed on these pages are available with various terminal enclosures including Economy, General Purpose, Weather and/or Explosion- Resistant. For dimensional and information on other terminal enclosures, see Terminal Enclosures section on pages Page 6

7 Screw Plug Heaters - Copper Sheathed Elements Typical Applications for Copper Sheathed Elements Clean Water Freeze Protection of Aqueous Solutions Other Aqueous Solutions not corrosive to Copper Sheath. 1" NPT BRASS Plug 0.5 to W/in 2 U.L. Listed 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (140) 55 (8.5) XFS C XFS C XFS C 1 3 (2) (172) 63 (9.8) XFS C XFS C XFS C 1 3 (2) (172) 84 (13) XFS C XFS C XFS C 1 3 (2) (242) 88 (13.6) XFS C XFS C XFS C 1 3 (2) (318) 86 (13.3) XFS C XFS C XFS C 1 3 (2) (381) 89 (13.8) XFS C XFS C XFS C 1 3 (2) 3 17 (432) 93 (14.4) XFS C XFS C XFS C 1 3 (2) 4 21 (534) 99 (15.3) XFS C XFS C XFS C 1 4 (2) 1¼" NPT BRASS Plug 0.5 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. U.L. Listed 120, 208, 240, & 480 Volt, Single Phase Immersion Watt Density 120V 208V 240V 480V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase 1 Phase Ele lb (kg) (140) 55 (8.5) XGS C XGS C XGS C 1 3 (2) (166) 63 (9.8) XGS C XGS C XGS C 1 3 (2) (140) 55 (8.5) XGS C XGS C XGS C 2 3 (2) (166) 68 (10.5) XGS C XGS C XGS C XGS C 2 4 (2) (166) 84 (13) XGS C XGS C XGS C XGS C 2 4 (2) (267) 65 (10.1) XGS C XGS C XGS C XGS C 2 4 (2) (242) 88 (13.6) XGS C XGS C XGS C XGS C 2 4 (2) 3 12 (305) 68 (10.5) XGS C XGS C XGS C XGS C 2 4 (2) (318) 86 (13.3) XGS C XGS C XGS C XGS C 2 4 (2) 4 15 (381) 70 (10.9) XGS C XGS C XGS C XGS C 2 5 (3) 5 15 (381) 89 (13.8) XGS C XGS C XGS C XGS C 2 4 (2) (470) 70 (10.9) XGS C XGS C XGS C XGS C 2 5 (3) 6 17 (432) 93 (14.4) XGS C XGS C XGS C XGS C 2 5 (3) 6 21 (534) 74 (11.5) XGS C XGS C XGS C XGS C 2 5 (3) Copper Sheathed Elements Page 7

8 Screw Plug Heaters - Copper Sheathed Elements 2" NPT BRONZE Plug U.L. Listed 1.5 to W/in 120 Volt, Single Phase (280) 61 (9.5) XPS C XPS C 1 4 (2) 2 8 (204) 61 (9.5) XPS-2-1-8C XPS C 2 4 (2) (242) 58 (9) XPS C XPS C 2 5 (3) 3 8 (204) 61 (9.5) XPS-3-1-8C XPS C XPS C*3 3 5 (3) 3 11 (280) 61 (9.5) XPS C XPS C 2 5 (3) 4 15 (381) 56 (8.7) XPS C XPS C 2 5 (3) (280) 61 (9.5) XPS C XPS C XPS C*3 3 5 (3) 5 18 (458) 57 (8.8) XPS C XPS C 2 5 (3) 6 15 (381) 56 (8.7) XPS C XPS C*3 3 6 (3) 6 21 (534) 58 (9) XPS C 2 6 (3) 7 25 (635) 60 (9.3) XPS C 2 6 (3) (458) 57 (8.8) XPS C XPS C*3 3 6 (3) 8 27 (686) 61 (9.5) XPS C 2 6 (3) 9 21 (534) 58 (9) XPS C XPS C*3 3 7 (4) (813) 61 (9.5) XPS C 2 7 (4) (686) 61 (9.5) XPS C*3 3 8 (4) (813) 61 (9.5) XPS C*3 3 9 (5) (280) 61 (9.5) XPS C XPS C 1 4 (2) 2 8 (204) 61 (9.5) XPS-2-2-8C XPS-2-4-8C 2 4 (2) (242) 58 (9) XPS C XPS C 2 5 (3) 3 8 (204) 61 (9.5) XPS-3-2-8C XPS-3-2-8C*3 XPS-3-4-8C XPS-3-4-8C*3 3 5 (3) 3 11 (280) 61 (9.5) XPS C XPS C 2 5 (3) 4 15 (381) 56 (8.7) XPS C XPS C 2 5 (3) (280) 61 (9.5) XPS C XPS C*3 XPS C XPS C*3 3 5 (3) 5 18 (458) 57 (8.8) XPS C XPS C 2 5 (3) 6 15 (381) 56 (8.7) XPS C XPS C*3 XPS C XPS C*3 3 6 (3) 6 21 (534) 58 (9) XPS C XPS C 2 6 (3) 7 25 (635) 60 (9.3) XPS C XPS C 2 6 (3) (458) 57 (8.8) XPS C XPS C*3 XPS C XPS C*3 3 6 (3) 8 27 (686) 61 (9.5) XPS C XPS C 2 6 (3) 9 21 (534) 58 (9) XPS C XPS C*3 XPS C XPS C*3 3 7 (4) (813) 61 (9.5) XPS C XPS C 2 7 (4) (686) 61 (9.5) XPS C*3 XPS C XPS C*3 3 8 (4) (966) 67 (10.4) XPS C+2 XPS C 2 7 (4) (813) 61 (9.5) XPS C*3 XPS C XPS C*3 3 9 (5) (966) 67 (10.4) XPS C*3 XPS C XPS C*3 3 9 (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 8

9 WARRE ARREN EL EC T RIC CO RP POR ATION Screw Plug Heaters - Copper Sheathed Elements 2½" NPT BRONZE Plug 3 to W/in (204) 61 (9.5) XRS-3-1-8C XRS C XRS C*3 3 5 (3) (280) 61 (9.5) XRS C XRS C XRS C*3 3 6 (3) 6 15 (381) 56 (8.7) XRS C XRS C*3 3 6 (3) (458) 57 (8.8) XRS C XRS C*3 3 7 (4) 9 21 (534) 58 (9) XRS C XRS C*3 3 7 (4) (686) 61 (9.5) XRS C*3 3 8 (4) (813) 61 (9.5) XRS C*3 3 9 (5) 3 8 (204) 61 (9.5) XRS-3-2-8C XRS-3-2-8C*3 XRS-3-4-8C XRS-3-4-8C*3 3 5 (3) (280) 61 (9.5) XRS C XRS C*3 XRS C XRS C*3 3 6 (3) 6 15 (381) 56 (8.7) XRS C XRS C*3 XRS C XRS C*3 3 6 (3) (458) 57 (8.8) XRS C XRS C*3 XRS C XRS C*3 3 7 (4) 9 21 (534) 58 (9) XRS C XRS C*3 XRS C XRS C*3 3 7 (4) (686) 61 (9.5) XRS C*3 XRS C XRS C*3 3 8 (4) (813) 61 (9.5) XRS C*3 XRS C XRS C*3 3 9 (5) (966) 67 (10.4) XRS C*3 XRS C XRS C* (5) 3" NPT STEEL Plug 6 to W/in 2 U.L. Listed 120 Volt, Single Phase U.L. Listed 120 Volt, Single Phase 6 8 (204) 61 (9.5) XCS-6-1-8C+2 XCS C XCS C* (5) 9 11 (280) 61 (9.5) XCS C+2 XCS C XCS C* (5) (381) 56 (8.7) XCS C+2 XCS C* (6) (458) 57 (8.8) XCS C+2 XCS C* (6) (534) 58 (9) XCS C+2 XCS C* (7) (661) 61 (9.5) XCS C* (7) (813) 61 (9.5) XCS C* (8) 6 8 (204) 61 (9.5) XCS-6-2-8C XCS-6-2-8C*3 XCS-6-4-8C XCS-6-4-8C* (5) 9 11 (280) 61 (9.5) XCS C XCS C*3 XCS C XCS C* (5) (381) 56 (8.7) XCS C XCS C*3 XCS C XCS C* (6) (458) 57 (8.8) XCS C+2 XCS C*3 XCS C XCS C* (6) (534) 58 (9) XCS C+2 XCS C*3 XCS C XCS C* (7) (661) 61 (9.5) XCS C+2 XCS C*3+2 XCS C+2 XCS C* (7) (813) 61 (9.5) XCS C*3+2 XCS C+2 XCS C* (8) (966) 67 (10.4) XCS C*3+2 XCS C+2 XCS C* (9) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 9 Copper Sheathed Elements

10 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements 6-11 WSI Residual Fuel Oils (Bunker C and #6) Asphalt Heavy Weight Lubrication Oils Static Heat Transfer Oils Hydraulic Fluids The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 2" NPT STEEL Plug 0.5 to 5 Low Watt Density 6-11 WSI 6-11 W/in Volt, Single Phase (305) 9 (1.4) XPS XPS (3) (305) 6 (0.9) XPS *3 3 6 (3) 1 18 (458) 8 (1.2) XPS XPS XPS *3 3 7 (4) (712) 9 (1.4) XPS XPS (4) (508) 10 (1.6) XPS XPS *3 3 7 (4) 2 28 (712) 9 (1.4) XPS XPS *3 3 8 (4) (762) 11 (1.7) XPS XPS *3 3 9 (5) 3 38 (966) 10 (1.6) XPS XPS * (5) 4 54 (1372) 9 (1.4) XPS XPS * (5) (305) 9 (1.4) XPS XPS (3) (305) 6 (0.9) XPS *3 XPS *3 3 6 (3) 1 18 (458) 8 (1.2) XPS XPS *3 XPS XPS *3 3 7 (4) (712) 9 (1.4) XPS XPS (4) (508) 10 (1.6) XPS XPS *3 XPS XPS *3 3 7 (4) 2 28 (712) 9 (1.4) XPS XPS *3 XPS XPS *3 3 8 (4) (762) 11 (1.7) XPS XPS *3 XPS XPS *3 3 9 (5) 3 38 (966) 10 (1.6) XPS XPS *3 XPS XPS * (5) 4 51 (1296) 9 (1.4) XPS XPS *3 XPS XPS * (5) 5 63 (1601) 10 (1.6) XPS XPS *3 XPS XPS * (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 10

11 Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug 0.5 to 5 Low Watt Density 6-11 WSI 6-11 W/in Volt, Single Phase (305) 6 (0.9) XRS XRS *3 3 7 (4) (305) 9 (1.4) XRS XRS XRS *3 3 7 (4) 1 18 (458) 8 (1.2) XRS XRS *3 3 8 (4) (508) 10 (1.6) XRS XRS *3 3 8 (4) 2 28 (712) 9 (1.4) XRS XRS *3 3 9 (5) (762) 11 (1.7) XRS XRS * (5) 3 38 (966) 10 (1.6) XRS XRS * (5) 4 54 (1372) 9 (1.4) XRS XRS * (6) (305) 6 (0.9) XRS XRS *3 XRS XRS *3 3 7 (4) (305) 9 (1.4) XRS XRS *3 XRS XRS *3 3 7 (4) 1 18 (458) 8 (1.2) XRS XRS *3 XRS XRS *3 3 8 (4) (508) 10 (1.6) XRS XRS *3 XRS XRS *3 3 8 (4) 2 28 (712) 9 (1.4) XRS XRS *3 XRS XRS *3 3 9 (5) (762) 11 (1.7) XRS XRS *3 XRS XRS * (5) 3 38 (966) 10 (1.6) XRS XRS *3 XRS XRS * (5) 4 51 (1296) 9 (1.4) XRS XRS *3 XRS XRS * (6) 5 63 (1601) 10 (1.6) XRS XRS *3 XRS XRS * (7) Steel Sheathed Elements WSI 3" NPT STEEL Plug 1.5 to W/in Volt, Single Phase (293) 9 (1.4) XCS XCS XCS * (5) 2 17 (432) 8 (1.2) XCS XCS XCS * (6) 3 20 (508) 10 (1.6) XCS XCS * (6) 4 28 (712) 9 (1.4) XCS XCS * (8) 5 30 (762) 11 (1.7) XCS XCS * (8) 6 38 (966) 10 (1.6) XCS XCS * (9) 8 54 (1372) 9 (1.4) XCS XCS * (11) (1677) 9 (1.4) XCS XCS * (13) (1982) 10 (1.6) XCS * (15) (293) 9 (1.4) XCS XCS *3 XCS (5) 2 17 (432) 8 (1.2) XCS XCS *3 XCS XCS * (6) 3 20 (508) 10 (1.6) XCS XCS *3 XCS XCS * (6) 4 28 (712) 9 (1.4) XCS XCS *3 XCS XCS * (8) 5 30 (762) 11 (1.7) XCS XCS *3 XCS XCS * (8) 6 38 (966) 10 (1.6) XCS XCS *3 XCS XCS * (9) 8 54 (1372) 9 (1.4) XCS XCS *3 XCS XCS * (11) (1677) 9 (1.4) XCS XCS *3 XCS XCS * (13) (1982) 10 (1.6) XCS XCS *3 XCS XCS * (15) Page 11

12 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements WSI Hydraulic Fluid Applications Medium Weight Oils Liquid Paraffin #4 and #5 Fuel Oils Heat Transfer Fluids 2" NPT STEEL Plug The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 1.5 to W/in Volt, Single Phase (331) 16 (2.5) XPS XPS XPS *3 3 6 (3) 2 25 (635) 16 (2.5) XPS XPS (4) (813) 16 (2.5) XPS XPS (4) 3 25 (635) 16 (2.5) XPS XPS XPS *3 3 8 (4) (1016) 16 (2.5) XPS XPS (4) 4 48 (1220) 16 (2.5) XPS (5) 4 32 (813) 16 (2.5) XPS XPS *3 3 9 (5) 5 57 (1448) 17 (2.6) XPS (5) 5 40 (1016) 16 (2.5) XPS XPS * (5) 6 68 (1728) 17 (2.6) XPS (5) 6 48 (1220) 16 (2.5) XPS XPS * (5) (1448) 17 (2.6) XPS XPS * (6) 9 68 (1728) 17 (2.6) XPS XPS * (7) (331) 16 (2.5) XPS XPS *3 XPS XPS *3 3 6 (3) 2 25 (635) 16 (2.5) XPS XPS (4) (813) 16 (2.5) XPS XPS (4) 3 25 (635) 16 (2.5) XPS XPS *3 XPS XPS *3 3 8 (4) (1016) 16 (2.5) XPS XPS (4) 4 48 (1220) 16 (2.5) XPS XPS (5) 4 32 (813) 16 (2.5) XPS XPS *3 XPS XPS *3 3 9 (5) 5 57 (1448) 17 (2.6) XPS XPS (5) 5 40 (1016) 16 (2.5) XPS XPS *3 XPS XPS * (5) 6 68 (1728) 17 (2.6) XPS XPS (5) 6 48 (1220) 16 (2.5) XPS XPS *3 XPS XPS * (5) (1448) 17 (2.6) XPS XPS *3 XPS XPS * (6) 9 68 (1728) 17 (2.6) XPS XPS *3 XPS XPS * (7) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 12

13 WARREN ELECTRIC CORPORATION War arren, en, Rho hode e Islan and Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug Watt Density WSI 120 Volt, Single Phase (331) 16 (2.5) XRS XRS XRS *3 3 7 (4) 2 17 (432) 16 (2.5) XRS XRS XRS *3 3 8 (4) (508) 17 (2.6) XRS XRS XRS *3 3 8 (4) 3 25 (635) 16 (2.5) XRS XRS XRS *3 3 9 (5) 4 32 (813) 16 (2.5) XRS XRS * (5) 5 40 (1016) 16 (2.5) XRS XRS * (5) 6 48 (1220) 16 (2.5) XRS XRS * (6) (331) 16 (2.5) XRS XRS *3 XRS XRS *3 3 5 (3) 2 17 (432) 16 (2.5) XRS XRS *3 XRS XRS *3 3 5 (3) (508) 17 (2.6) XRS XRS *3 XRS XRS *3 3 5 (3) 3 25 (635) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 4 32 (813) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 5 40 (1016) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) 6 48 (1220) 16 (2.5) XRS XRS *3 XRS XRS *3 3 6 (3) (1448) 17 (2.6) XRS XRS *3 XRS XRS *3 3 7 (4) 9 68 (1728) 17 (2.6) XRS XRS *3 XRS XRS *3 3 7 (4) 3" NPT STEEL Plug 1.5 to W/in 2 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 13 (331) 16 (2.5) XCS XCS XCS * (5) 4 17 (432) 16 (2.5) XCS XCS XCS * (6) 5 20 (508) 17 (2.6) XCS XCS XCS * (6) 6 25 (635) 16 (2.5) XCS XCS XCS * (7) 8 32 (813) 16 (2.5) XCS XCS * (8) (1016) 16 (2.5) XCS XCS * (9) (1220) 16 (2.5) XCS XCS * (10) 3 13 (331) 16 (2.5) XCS XCS *3 XCS XCS * (5) 4 17 (432) 16 (2.5) XCS XCS *3 XCS XCS * (6) 5 20 (508) 17 (2.6) XCS XCS *3 XCS XCS * (6) 6 25 (635) 16 (2.5) XCS XCS *3 XCS XCS * (7) 8 32 (813) 16 (2.5) XCS XCS *3 XCS XCS * (8) (1016) 16 (2.5) XCS XCS *3 XCS XCS * (9) (1220) 16 (2.5) XCS XCS *3 XCS XCS * (10) (1448) 17 (2.6) XCS XCS *3 XCS XCS * (11) (1728) 17 (2.6) XCS XCS *3 XCS XCS * (13) Page 13 Steel Sheathed Elements WSI

14 Screw Plug Heaters - Steel Sheathed Elements Typical Applications for Steel Sheathed Elements WSI Degreasing Solutions Mineral Oils Light Lubrication Oils Flowing Hydraulic Fluids Flowing HeatTransfer Fluids The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 1-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 1" NPT STEEL Plug Watt Density 23 WSI 0.25 to W/in 2 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (166) 23 (3.6) XFS (2) (242) 23 (3.6) XFS XFS XFS (2) (305) 23 (3.6) XFS XFS XFS (2) (458) 23 (3.6) XFS XFS XFS (2) 1 23 (585) 23 (3.6) XFS XFS XFS (2) (864) 23 (3.6) XFS XFS XFS (2) 1¼" NPT STEEL Plug 0.5 to 3 Watt Density 23 WSI 23 W/in 2 120, 208, & 240 Volt, Single Phase Immersion Watt Density 120V 208V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 1 Phase Ele lb (kg) (166) 23 (3.6) XGS XGS XGS (2) (242) 23 (3.6) XGS XGS XGS (2) 1 12 (305) 23 (3.6) XGS XGS XGS (2) (458) 23 (3.6) XGS XGS XGS (3) 2 23 (585) 23 (3.6) XGS XGS XGS (3) 3 34 (864) 23 (3.6) XGS XGS XGS (4) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 14

15 Screw Plug Heaters - Steel Sheathed Elements 2" NPT STEEL Plug 2" NPT STEEL Plug 1.5 to 12.5 Watt Density WSI W/in Volt, Single Phase (305) 27 (4.2) XPS XPS (3) 2 18 (458) 24 (3.7) XPS XPS (3) (508) 25 (3.9) XPS XPS (3) 3 25 (635) 24 (3.7) XPS XPS (4) 3 18 (458) 24 (3.7) XPS XPS XPS *3 3 7 (4) (826) 24 (3.7) XPS XPS (4) (635) 24 (3.7) XPS XPS XPS *3 3 8 (4) (1207) 24 (3.7) XPS (5) (826) 24 (3.7) XPS XPS *3 3 9 (5) (1016) 24 (3.7) XPS XPS * (5) (1207) 24 (3.7) XPS XPS * (5) (1626) 24 (3.7) XPS * (7) 1.5 to 12.5 Watt Density WSI W/in (305) 27 (4.2) XPS XPS (3) 2 18 (458) 24 (3.7) XPS XPS (3) (508) 25 (3.9) XPS XPS (3) 3 25 (635) 24 (3.7) XPS XPS (4) 3 18 (458) 24 (3.7) XPS XPS *3 XPS XPS *3 3 7 (4) (826) 24 (3.7) XPS XPS (4) (635) 24 (3.7) XPS XPS *3 XPS XPS *3 3 8 (4) 5 40 (1016) 24 (3.7) XPS XPS (4) (1207) 24 (3.7) XPS XPS (5) (826) 24 (3.7) XPS XPS *3 XPS XPS *3 3 9 (5) (1016) 24 (3.7) XPS XPS *3 XPS XPS * (5) (1207) 24 (3.7) XPS XPS *3 XPS XPS * (5) (1626) 24 (3.7) XPS XPS *3 XPS XPS * (7) Steel Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 15

16 Screw Plug Heaters - Steel Sheathed Elements 2½" NPT STEEL Plug 3" NPT STEEL Plug 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 18 (458) 24 (3.7) XRS XRS XRS *3 3 8 (4) (635) 24 (3.7) XRS XRS XRS *3 3 9 (5) (826) 24 (3.7) XRS XRS * (5) (1016) 24 (3.7) XRS XRS * (5) (1207) 24 (3.7) XRS XRS * (6) (1626) 24 (3.7) XRS * (7) 3 18 (458) 24 (3.7) XRS XRS *3 XRS XRS *3 3 8 (4) (635) 24 (3.7) XRS XRS *3 XRS XRS *3 3 9 (5) (826) 24 (3.7) XRS XRS *3 XRS XRS * (5) (1016) 24 (3.7) XRS XRS *3 XRS XRS * (5) (1207) 24 (3.7) XRS XRS *3 XRS XRS * (6) (1626) 24 (3.7) XRS *3 XRS XRS * (7) (1931) 25 (3.9) XRS *3 XRS XRS * (8) 6 to 30 Watt Density WSI W/in Volt, Single & Three Phase Immersion Watt Density 208V 208V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 3 Phase Ele lb (kg) 6 18 (458) 24 (3.7) XCS XCS * (6) 9 25 (635) 24 (3.7) XCS XCS * (7) (826) 24 (3.7) XCS * (8) (1016) 24 (3.7) XCS * (9) 6 18 (458) 24 (3.7) XCS XCS *3 XCS XCS * (6) 9 25 (635) 24 (3.7) XCS XCS *3 XCS XCS * (7) (826) 24 (3.7) XCS XCS *3 XCS XCS * (8) (1016) 24 (3.7) XCS XCS *3 XCS XCS * (9) (1207) 24 (3.7) XCS XCS *3 XCS XCS * (10) (1626) 24 (3.7) XCS *3+2 XCS XCS * (12) (1931) 25 (3.9) XCS *3+2 XCS XCS * (14) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 16

17 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Citric-Based Fluids Flowing Steam and many Highlky Corrosive Chemical Solutions 2" NPT S.S. Plug The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 2 to W/in Volt, Single Phase 2 25 (635) 16 (2.5) XPS IC XPS IC 2 7 (4) 3 25 (635) 16 (2.5) XPS IC XPS IC XPS IC*3 3 8 (4) (1016) 16 (2.5) XPS IC XPS IC 2 8 (4) 4 48 (1220) 16 (2.5) XPS IC XPS IC 2 9 (5) 5 56 (1423) 17 (2.6) XPS IC XPS IC 2 10 (5) 5 40 (1016) 16 (2.5) XPS IC XPS IC XPS IC* (5) 6 67 (1702) 17 (2.6) XPS IC 2 11 (5) 6 48 (1220) 16 (2.5) XPS IC XPS IC* (5) (1423) 17 (2.6) XPS IC XPS IC* (6) 9 67 (1702) 17 (2.6) XPS IC XPS IC* (7) 2 25 (635) 16 (2.5) XPS IC XPS IC 2 7 (4) 3 25 (635) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) (1016) 16 (2.5) XPS IC XPS IC 2 8 (4) 4 48 (1220) 16 (2.5) XPS IC XPS IC 2 9 (5) 5 56 (1423) 17 (2.6) XPS IC XPS IC 2 10 (5) 5 40 (1016) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC* (5) 6 67 (1702) 17 (2.6) XPS IC XPS IC 2 11 (5) 6 48 (1220) 16 (2.5) XPS IC XPS IC*3 XPS IC XPS IC* (5) (1423) 17 (2.6) XPS IC XPS IC*3 XPS IC XPS IC* (6) 9 67 (1702) 17 (2.6) XPS IC XPS IC*3 XPS IC XPS IC* (7) Incoloy Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 17

18 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to 9 Watt Density WSI W/in Volt, Single Phase 3 25 (635) 16 (2.5) XRS IC XRS IC XRS IC*3 3 9 (5) 4 32 (813) 16 (2.5) XRS IC XRS IC XRS IC* (5) 5 40 (1016) 16 (2.5) XRS IC XRS IC* (5) 6 48 (1220) 16 (2.5) XRS IC XRS IC* (6) (1423) 17 (2.6) XRS IC XRS IC* (7) 9 67 (1702) 17 (2.6) XRS IC XRS IC* (8) 3 25 (635) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) 4 32 (813) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (5) 5 40 (1016) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (5) 6 48 (1220) 16 (2.5) XRS IC XRS IC*3 XRS IC XRS IC* (6) (1423) 17 (2.6) XRS IC XRS IC*3 XRS IC XRS IC* (7) 9 67 (1702) 17 (2.6) XRS IC XRS IC*3 XRS IC XRS IC* (8) 3" NPT S.S. Plug 6 to 18 Watt Density WSI W/in Volt, Single Phase 6 25 (635) 16 (2.5) XCS IC+2 XCS IC XCS IC* (7) 8 32 (813) 16 (2.5) XCS IC+2 XCS IC XCS IC* (8) (1016) 16 (2.5) XCS IC XCS IC* (10) (1220) 16 (2.5) XCS IC+2 XCS IC* (10) (1423) 17 (2.6) XCS IC+2 XCS IC* (12) (1702) 17 (2.6) XCS IC+2 XCS IC* (13) 6 25 (635) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (7) 8 32 (813) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (8) (1016) 16 (2.5) XCS IC XCS IC*3 XCS IC XCS IC* (10) (1220) 16 (2.5) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1423) 17 (2.6) XCS IC+2 XCS IC*3 XCS IC XCS IC* (12) (1702) 17 (2.6) XCS IC+2 XCS IC*3 XCS IC XCS IC* (13) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 18

19 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Forced Air & Gases Vegetable Oils Ethylene Glycol Causic Solutions and many Mildly Corrosive Chemical Solutions 1" NPT S.S. Plug Watt Density WSI to W/in 2 Immersion Watt Density 120V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase Ele lb (kg) (242) 22 (3.4) XFS IC XFS IC 1 3 (2) (305) 23 (3.6) XFS IC XFS IC 1 3 (2) (458) 22 (3.4) XFS IC XFS IC 1 4 (2) 1 23 (585) 23 (3.6) XFS IC XFS IC 1 4 (2) 1¼" NPT S.S. Plug 0.75 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. 120 & 240 Volt, Single Phase 120 & 240 Volt, Single Phase Incoloy Sheathed Elements WSI Immersion Watt Density 120V 240V No. Est Weight in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase Ele lb (kg) (242) 22 (3.4) XGS IC XGS IC 2 4 (2) 1 12 (305) 23 (3.6) XGS IC XGS IC 2 4 (2) (458) 22 (3.4) XGS IC XGS IC 2 5 (3) 2 23 (585) 23 (3.6) XGS IC XGS IC 2 5 (3) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 19

20 Screw Plug Heaters - Incoloy Sheathed Elements 2" NPT S.S. Plug 2 to 15 Watt Density WSI W/in Volt, Single Phase 18 (458) 23 (3.6) XPS IC XPS IC 2 6 (3) 25 (635) 24 (3.7) XPS IC-Y XPS IC-Y 2 7 (4) 18 (458) 24 (3.7) XPS IC XPS IC XPS IC*3 3 7 (4) 33 (839) 24 (3.7) XPS IC XPS IC 2 7 (4) 25 (635) 24 (3.7) XPS IC XPS IC XPS IC*3 3 8 (4) 40 (1016) 24 (3.7) XPS IC XPS IC 2 8 (4) 48 (1220) 24 (3.7) XPS IC 2 9 (5) 33 (839) 24 (3.7) XPS IC XPS IC*3 3 9 (5) 40 (1016) 24 (3.7) XPS IC XPS IC* (5) 48 (1220) 24 (3.7) XPS IC XPS IC* (5) 64 (1626) 24 (3.7) XPS IC* (7) 2 18 (458) 23 (3.6) XPS IC XPS IC 2 6 (3) 3 25 (635) 24 (3.7) XPS IC XPS IC 2 7 (4) 3 18 (458) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) 4 33 (839) 24 (3.7) XPS IC XPS IC 2 7 (4) (635) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) 5 40 (1016) 24 (3.7) XPS IC XPS IC 2 8 (4) 6 48 (1220) 24 (3.7) XPS IC XPS IC 2 9 (5) 6 33 (839) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC*3 3 9 (5) (1016) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC* (5) 9 48 (1220) 24 (3.7) XPS IC XPS IC*3 XPS IC XPS IC* (5) (1626) 24 (3.7) XPS IC*3 XPS IC XPS IC* (7) (2007) 24 (3.7) XPS IC*3 XPS IC XPS IC* (8) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 20

21 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to W/in 2 Watt Density WSI 120 Volt, Single Phase 3 18 (458) 23 (3.6) XRS IC XRS IC XRS IC*3 3 8 (4) (635) 24 (3.7) XRS IC XRS IC XRS IC*3 3 9 (5) 6 33 (839) 24 (3.7) XRS IC XRS IC* (5) (1016) 24 (3.7) XRS IC XRS IC* (5) 9 48 (1220) 24 (3.7) XRS IC XRS IC* (6) (1626) 24 (3.7) XRS IC* (7) 3 18 (458) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) (635) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) 6 33 (839) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (5) (1016) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (5) 9 48 (1220) 24 (3.7) XRS IC XRS IC*3 XRS IC XRS IC* (6) (1626) 24 (3.7) XRS IC*3 XRS IC XRS IC* (7) (2007) 24 (3.7) XRS IC*3 XRS IC XRS IC* (8) 3" NPT S.S. Plug 6 to 30 Watt Density WSI W/in Volt, Single Phase 6 18 (458) 23 (3.6) XCS IC+2 XCS IC XCS IC* (6) 9 25 (635) 24 (3.7) XCS IC+2 XCS IC XCS IC* (7) (839) 24 (3.7) XCS IC+2 XCS IC* (8) (1016) 24 (3.7) XCS IC+2 XCS IC* (10) (1220) 24 (3.7) XCS IC+2 XCS IC* (10) 6 18 (458) 23 (3.6) XCS IC XCS IC*3 XCS IC XCS IC* (6) 9 25 (635) 24 (3.7) XCS IC XCS IC*3 XCS IC XCS IC* (7) (839) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (8) (1016) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1220) 24 (3.7) XCS IC+2 XCS IC*3 XCS IC XCS IC* (10) (1626) 24 (3.7) XCS IC*3+2 XCS IC+2 XCS IC* (13) (2007) 24 (3.7) XCS IC*3+2 XCS IC+2 XCS IC* (15) Incoloy Sheathed Elements WSI For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 21

22 Screw Plug Heaters - Incoloy Sheathed Elements Typical Applications for Incoloy Sheathed Elements WSI Process Water Deionized Water (Passivated) Potable Water 2" NPT S.S. Plug 2 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 120 Volt, Single Phase 2 9 (229) 51 (7.9) XPS-2-1-9IC XPS IC 2 5 (3) 3 13 (331) 49 (7.6) XPS IC XPS IC 2 5 (3) 3 9 (229) 51 (7.9) XPS-3-1-9IC XPS IC XPS IC*3 3 6 (3) (445) 47 (7.3) XPS IC XPS IC 2 6 (3) (331) 49 (7.6) XPS IC XPS IC XPS IC*3 3 6 (3) 5 20 (508) 51 (7.9) XPS IC XPS IC 2 6 (3) 6 25 (635) 48 (7.4) XPS IC 2 7 (4) (445) 47 (7.3) XPS IC XPS IC*3 3 7 (4) (508) 51 (7.9) XPS IC XPS IC*3 3 7 (4) 8 32 (813) 49 (7.6) XPS IC 2 7 (4) 9 25 (635) 48 (7.4) XPS IC XPS IC*3 3 8 (4) (813) 49 (7.6) XPS IC*3 3 9 (5) (1016) 48 (7.4) XPS IC* (5) 2 9 (229) 51 (7.9) XPS-2-2-9IC XPS-2-4-9IC 2 5 (3) 3 13 (331) 49 (7.6) XPS IC XPS IC 2 5 (3) 3 9 (229) 51 (7.9) XPS-3-2-9IC XPS-3-2-9IC*3 XPS-3-4-9IC XPS-3-4-9IC*3 3 6 (3) (445) 47 (7.3) XPS IC XPS IC 2 6 (3) (331) 49 (7.6) XPS IC XPS IC*3 XPS IC XPS IC*3 3 6 (3) 5 20 (508) 51 (7.9) XPS IC XPS IC 2 6 (3) 6 25 (635) 48 (7.4) XPS IC XPS IC 2 7 (4) (445) 47 (7.3) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) (508) 51 (7.9) XPS IC XPS IC*3 XPS IC XPS IC*3 3 7 (4) 8 32 (813) 49 (7.6) XPS IC XPS IC 2 7 (4) 9 25 (635) 48 (7.4) XPS IC XPS IC*3 XPS IC XPS IC*3 3 8 (4) (1016) 48 (7.4) XPS IC XPS IC 2 8 (4) (1220) 48 (7.4) XPS IC 2 9 (5) (813) 49 (7.6) XPS IC*3 XPS IC XPS IC*3 3 9 (5) (1016) 48 (7.4) XPS IC*3 XPS IC XPS IC* (5) (1220) 48 (7.4) XPS IC*3 XPS IC XPS IC* (5) For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Page 22

23 Screw Plug Heaters - Incoloy Sheathed Elements 2½" NPT S.S. Plug 3 to 18 Watt Density WSI W/in Volt, Single Phase 3 9 (229) 51 (7.9) XRS-3-1-9IC XRS IC XRS IC*3 3 7 (4) (331) 49 (7.6) XRS IC XRS IC XRS IC*3 3 7 (4) (445) 47 (7.3) XRS IC XRS IC*3 3 8 (4) (508) 51 (7.9) XRS IC XRS IC*3 3 8 (4) 9 25 (635) 48 (7.4) XRS IC XRS IC*3 3 9 (5) (813) 49 (7.6) XRS IC* (5) (1016) 48 (7.4) XRS IC* (5) 3 9 (229) 51 (7.9) XRS-3-2-9IC XRS-3-2-9IC*3 XRS-3-4-9IC XRS-3-4-9IC*3 3 7 (4) (331) 49 (7.6) XRS IC XRS IC*3 XRS IC XRS IC*3 3 7 (4) (445) 47 (7.3) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) (508) 51 (7.9) XRS IC XRS IC*3 XRS IC XRS IC*3 3 8 (4) 9 25 (635) 48 (7.4) XRS IC XRS IC*3 XRS IC XRS IC*3 3 9 (5) (813) 49 (7.6) XRS IC*3 XRS IC XRS IC* (5) (1016) 48 (7.4) XRS IC*3 XRS IC XRS IC* (5) (1220) 48 (7.4) XRS IC*3 XRS IC XRS IC* (6) 3" NPT S.S. Plug 6 to 36 Watt Density WSI W/in Volt, Single Phase 6 9 (229) 51 (7.9) XCS-6-1-9IC+2 XCS IC XCS IC* (5) 9 13 (331) 49 (7.6) XCS IC+2 XCS IC XCS IC* (5) (445) 47 (7.3) XCS IC+2 XCS IC* (6) (508) 51 (7.9) XCS IC+2 XCS IC* (7) (635) 48 (7.4) XCS IC+2 XCS IC* (7) (813) 49 (7.6) XCS IC* (8) (1016) 48 (7.4) XCS IC* (10) 6 9 (229) 55 (8.5) XCS-6-2-9IC XCS-6-2-9IC*3 XCS-6-4-9IC XCS-6-4-9IC* (5) 9 13 (331) 52 (8.1) XCS IC XCS IC*3 XCS IC XCS IC* (5) (445) 47 (7.3) XCS IC+2 XCS IC*3 XCS IC XCS IC* (6) (508) 50 (7.8) XCS IC+2 XCS IC*3 XCS IC XCS IC* (7) (635) 47 (7.3) XCS IC+2 XCS IC*3 XCS IC XCS IC* (7) (813) 49 (7.6) XCS IC*3+2 XCS IC+2 XCS IC* (8) (1016) 48 (7.4) XCS IC*3+2 XCS IC+2 XCS IC* (10) 36For models 48 (1220) or options 48 not (7.4) listed, please refer to our XCS IC*3+2 Quick Quote XCS IC+2 on the back inside XCS IC*3 cover or consult 6factory. 22 (10) Page 23 Incoloy Sheathed Elements WSI

24 Screw Plug Heaters - Stainless Sheathed Elements Typical Applications for Stainless Sheathed Elements WSI Deionized Water (Passivated) Mild Alkaline Solutions 2" NPT S.S. Plug 2 to W/in 2 The models listed on these pages do not have thermostats, but are available with thermostats. A thermowell is standard in the design of the heaters listed in this catalog to allow for a thermostat/temperature sensing device. To add a thermostat with a F range, replace: X in model number with 2-. A heater ordered with a thermostat will be supplied with a high profile terminal enclosure. Watt Density WSI 120 Volt, Single Phase Immersion Watt Density 120V 208V 208V No. in (mm) W/in 2 (W/cm 2 ) 1 Phase 1 Phase 3 Phase Ele 2 9 (229) 51 (7.9) XPS-2-1-9SS XPS SS (331) 49 (7.6) XPS SS XPS SS (229) 51 (7.9) XPS-3-1-9SS XPS SS XPS SS* (445) 47 (7.3) XPS SS XPS SS (331) 49 (7.6) XPS SS XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS (635) 48 (7.4) XPS SS (445) 47 (7.3) XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS* (813) 49 (7.6) XPS SS (635) 48 (7.4) XPS SS XPS SS* (813) 49 (7.6) XPS SS* (1016) 48 (7.4) XPS SS* V 240V 480V 480V No. in (mm) W/in 2 (W/cm 2 ) 1 Phase 3 Phase 1 Phase 3 Phase Ele 2 9 (229) 51 (7.9) XPS-2-2-9SS XPS-2-4-9SS (331) 49 (7.6) XPS SS XPS SS (229) 51 (7.9) XPS-3-2-9SS XPS-3-2-9SS*3 XPS-3-4-9SS XPS-3-4-9SS* (445) 47 (7.3) XPS SS XPS SS (331) 49 (7.6) XPS SS XPS SS*3 XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS (635) 48 (7.4) XPS SS XPS SS (445) 47 (7.3) XPS SS XPS SS*3 XPS SS XPS SS* (508) 51 (7.9) XPS SS XPS SS*3 XPS SS XPS SS* (813) 49 (7.6) XPS SS XPS SS (635) 48 (7.4) XPS SS XPS SS*3 XPS SS XPS SS* (1016) 48 (7.4) XPS SS XPS SS (1220) 48 (7.4) XPS SS (813) 49 (7.6) XPS SS*3 XPS SS XPS SS* (1016) 48 (7.4) XPS SS*3 XPS SS XPS SS* (1220) 48 (7.4) XPS SS*3 XPS SS XPS SS*3 3 For models or options not listed, please refer to our Quick Quote on the back inside cover or consult factory. Immersion Watt Density Page 24

25 Screw Plug Heaters - Stainless Sheathed Elements 2½" NPT S.S. Plug 3 to 18 Watt Density WSI W/in Volt, Single Phase 3 9 (229) 51 (7.9) XRS-3-1-9SS XRS SS XRS SS*3 3 7 (4) (331) 49 (7.6) XRS SS XRS SS XRS SS*3 3 7 (4) (445) 47 (7.3) XRS SS XRS SS*3 3 8 (4) (508) 51 (7.9) XRS SS XRS SS*3 3 8 (4) 9 25 (635) 48 (7.4) XRS SS XRS SS*3 3 9 (5) (813) 49 (7.6) XRS SS* (5) (1016) 48 (7.4) XRS SS* (5) 3 9 (229) 51 (7.9) XRS-3-2-9SS XRS-3-2-9SS*3 XRS-3-4-9SS XRS-3-4-9SS*3 3 7 (4) (331) 49 (7.6) XRS SS XRS SS*3 XRS SS XRS SS*3 3 7 (4) (445) 47 (7.3) XRS SS XRS SS*3 XRS SS XRS SS*3 3 8 (4) (508) 51 (7.9) XRS SS XRS SS*3 XRS SS XRS SS*3 3 8 (4) 9 25 (635) 48 (7.4) XRS SS XRS SS*3 XRS SS XRS SS*3 3 9 (5) (813) 49 (7.6) XRS SS*3 XRS SS XRS SS* (5) (1016) 48 (7.4) XRS SS*3 XRS SS XRS SS* (5) (1220) 48 (7.4) XRS SS*3 XRS SS XRS SS* (6) 3" NPT S.S. Plug 6 to 30 Watt Density WSI W/in Volt, Single Phase 6 9 (229) 51 (7.9) XCS-6-1-9SS+2 XCS SS XCS SS* (5) 9 13 (331) 49 (7.6) XCS SS+2 XCS SS XCS SS* (5) (445) 47 (7.3) XCS SS+2 XCS SS* (6) (508) 51 (7.9) XCS SS+2 XCS SS* (7) (635) 48 (7.4) XCS SS+2 XCS SS* (7) (813) 49 (7.6) XCS SS* (8) (1016) 48 (7.4) XCS SS* (10) 6 9 (229) 51 (7.9) XCS-6-2-9SS XCS-6-2-9SS*3 XCS-6-4-9SS XCS-6-4-9SS* (5) 9 13 (331) 49 (7.6) XCS SS XCS SS*3 XCS SS XCS SS* (5) (445) 47 (7.3) XCS SS+2 XCS SS*3 XCS SS XCS SS* (6) (508) 51 (7.9) XCS SS+2 XCS SS*3 XCS SS XCS SS* (7) (635) 48 (7.4) XCS SS+2 XCS SS*3 XCS SS XCS SS* (7) (813) 49 (7.6) XCS SS*3+2 XCS SS+2 XCS SS* (8) (1016) 48 (7.4) XCS SS*3+2 XCS SS+2 XCS SS* (10) (1220) 48 (7.4) XCS SS*3+2 XCS SS+2 XCS SS* (10) Page 25 Stainl ainless s She heathe hed Element ements s WSI

26 Thermostat/Thermowell Information A specific wiring instruction sheet is provided with each heater. All heaters listed in this catalog are shown without thermostats, but do have integral thermowells. All heaters without thermostats and/or thermocouples are provided with low profile terminal enclosures unless otherwise requested. However, all heaters are available with our standard SPST Thermostats. Other ranges and DPST thermostats are also available. Please advise factory of your request. Remote mount thermostats with thermowells also are available, as well as manual reset cutouts, thermocouples, pilot lights, and RTD s. Specify enclosure type, minimum capillary length, and thermowell material and length when ordering. Please consult our Applications Engineers for further information. Please note: Thermostats are not a fail safe device. Users should install To Add Thermostat: adequate controls or safety devices to control failure. Replace existing prefix X in our model number and add prefix: 1- for F range F Range SPST Thermostat ( C) 2- for F range F Range SPST Thermostat ( C) 3- for F range F Range SPST Thermostat ( C) For exmaple Thermocouples For applications that require a more accurate temperature sensing device than a thermostat, a built in thermocouple such as Type J or K can be provided. A thermocouple only senses temperature and must be used in conjunction with a controller (provided by another source). A thermocouple can be purchased with either a grounded or ungrounded junction and you need to inform us which type you need for your controller. Warren Electric uses the ungrounded type thermocouples as a standard. When using a thermocouple you need to have a separate conduit opening for the thermocouple wires. The Type J thermocouples are conductors of iron and constantan with a maximum operating temperature of 1400 F (normally used for applications up to 800 F). It is normally used in liquid applications. The Type K thermocouples are conductors of alumel and chromel with a maximum operating temperature of 2300 F (normally used for applications over 800 F). It is normally used in gas applications To Add Thermocouple RTD S 1-GS C is a model with a SPST thermostat with F range Replace existing prefix X and add prefix 5- for Thermocouple For example: 5-GS C is a model with a thermocouple To Add RTD For even more accurate temperature sensing than a thermocouple, a RTD is recommended. RTD s are available with two, Replace existing prefix X and add prefix three and four wires for different types of applications. For 7- for RTD further information, feel free to contact our Application Engineers. e.g. 7-GS C is a model with a RTD An integral thermostat, if provided, is designed for temperature control service only. A thermostat is not fail safe. It should not be used for temperature limiting duty. The system designer is responsible to install adequate back-up controls and safety devices. Where the consequences of failure could result in bodily or property injury, back-up controls are essential. Page 26

27 Casings & Assemblies Standard and custom design casings are available for all screw plug models. All casings can be manufactured with virtually any type and size of inlet, outlet, drain, and/or vent to suit your application. Pressure ratings for casings for screw plug heaters from 150 to 1500 PSIG (including ASME certification) are available. High temperature insulation and jacketing are also available for all casing models as requested. Please submit details to our Applications Engineer for quote. Max. Heater Imm. Length (in.) 2" NPT Casings 2-1/2" NPT Casings 3" NPT Casings Casing Model Number "A" (in.) Max. Heater Imm. Length (in.) Casing Model Number Max. Heater Imm. Length (in.) Casing Model Number 6 SP-S-6 7 1/2 6 SP-R SP-C SP-S-8 9 1/2 8 SP-R SP-C SP-S /2 10 SP-R SP-C SP-S /2 12 SP-R SP-C SP-S /2 14 SP-R SP-C SP-S /2 16 SP-R SP-C SP-S /2 18 SP-R SP-C SP-S /2 20 SP-R SP-C SP-S /2 22 SP-R SP-C SP-S /2 24 SP-R SP-C SP-S /2 26 SP-R SP-C SP-S /2 28 SP-R SP-C SP-S /2 30 SP-R SP-C SP-S /2 32 SP-R SP-C SP-S /2 34 SP-R SP-C SP-S /2 36 SP-R SP-C SP-S /2 38 SP-R SP-C SP-S /2 40 SP-R SP-C SP-S /2 42 SP-R SP-C SP-S /2 44 SP-R SP-C SP-S /2 46 SP-R SP-C SP-S /2 48 SP-R SP-C SP-S /2 50 SP-R SP-C SP-S /2 52 SP-R SP-C SP-S /2 54 SP-R SP-C SP-S /2 56 SP-R SP-C SP-S /2 58 SP-R SP-C SP-S /2 60 SP-R SP-C SP-S /2 62 SP-R SP-C SP-S /2 64 SP-R SP-C SP-S /2 66 SP-R SP-C SP-S /2 68 SP-R SP-C SP-S /2 70 SP-R SP-C SP-S /2 72 SP-R SP-C SP-S /2 74 SP-R SP-C SP-S /2 76 SP-R SP-C SP-S /2 78 SP-R SP-C SP-S /2 80 SP-R SP-C "A" (in.) "A" (in.) Insulated and Jacketed Casing Assemblies All Warren Electric casings are available insulated and jacketed for high temperature applications where process heat losses are to be kept at a minimum. Casings are furnished with calcium silicate insulation and steel jackets. Page 27

Immersion Heaters. Screw Plug Immersion Heater

Immersion Heaters. Screw Plug Immersion Heater Screw plug immersion heaters are ideal for direct immersion heating of liquids, including all types of oils and heat transfer solutions. Available in a variety of sizes, screw plug immersion heaters feature

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Overview consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. are screwed directly through a threaded opening in

More information

Tubular Industrial Process

Tubular Industrial Process are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating type heaters, to a pipe. See

More information

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately

More information

Differences Among Screw Plug Immersion Heaters

Differences Among Screw Plug Immersion Heaters PDS QUALITY Differences Among Screw Plug Immersion Heaters On first impression, various manufacturers of screw plug immersion heaters appear to be all alike; but when you take a closer look at screw plug

More information

Tubular Industrial Process

Tubular Industrial Process Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round

More information

Tubular Industrial Process

Tubular Industrial Process consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call  2-1/2 Pipe Thread Heaters Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. 1 2-1/2 Pipe Thread Heaters Construction Features 1" 2-1/2" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging of hex, thread and riser assures reliability. Element

More information

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire? PDS QUALITY On first impression, various manufacturers of screw plug immersion heaters appear to be all alike; but when you take a closer look at screw plug immersion heaters, it becomes evident that considerable

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Checklist Selecting the Proper Flanged Heater

Checklist Selecting the Proper Flanged Heater are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating type heaters, to a pipe. See

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

STRAIGHT & FORMED TUBULAR HEATERS

STRAIGHT & FORMED TUBULAR HEATERS STRAIGHT & FORMED TUBULAR HEATERS Applications: FORMING MACHINES HEATING MOLDS & PLATENS IMMERSION INTO LIQUIDS RADIANT & CONVECTION HEATING EMBEDDED OR CAST INTO METAL Tubular heaters are the main heating

More information

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX Heaters - CX Heaters CX Application heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating

More information

Screw plug immersion heaters

Screw plug immersion heaters Screw plug HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE The screw plug by CETAL are designed and manufactured as a standard range or according to customer specifications. Reliability

More information

( )

( ) (1-800-492-8826) FANGE HEATERS OVERVIEW WATTCO flange heaters are made using hairpin or bugle type tubular elements using incoloy sheathed elements that are welded or silver-brazed into a pipe or steel

More information

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation. DH & DHT Series ir Duct Heaters 5-300 kw 240 and 480 Volt, Three Phase (Up to 600V vailable) DH Typical Installation DHT Typical Installation INCOLOY Sheath Elements 800 F Max. Outlet ir Temp. (DH) 1200

More information

( )

( ) (1-800-492-8826) OVERVIEW WATTCO over-the-side are made of sidemounted tubular elements. Perfectly designed for freeze protection, for heating viscous solutions, water, oils, solvents, salts, and acids.

More information

Strip/Clamp-On Heaters

Strip/Clamp-On Heaters Max. Operating Typical Max. Temperatures Watt Densities Strip/Clamp-On Heaters Sheath Materials F C W/in 2 W/cm 2 Page Mineral Insulated (MI) 304 stainless steel 1400 760 140 21.7 477 375 High-Temperature

More information

OVER-THE-SIDE HEATERS. immersion heaters

OVER-THE-SIDE HEATERS. immersion heaters OVER-THE-SIDE HEATERS OVERVIEW WATTCO over-the-side are made of sidemounted tubular elements. Perfectly designed for freeze protection, for heating viscous solutions, water, oils, solvents, salts, and

More information

SCREWPLUG HEATERS. immersion heaters

SCREWPLUG HEATERS. immersion heaters SCREWPLUG HETERS SCREWPLUG HETERS OVERVIEW WTTCO screwplug heaters are comprised of hairpin tubular elements that are brazed or welded into a machined pipe thread fitting, which are then screwed directly

More information

Flange Heaters Type CX

Flange Heaters Type CX pplication Flange heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating element watt density.

More information

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating Process air duct heaters are used for tempering forced air in many industrial processes. Heater wattage is dependent on air outlet temperature (up to 1200 F [650 C]) and air velocity. Smaller duct heaters

More information

Cartridge Heaters. Components. Application Guidelines

Cartridge Heaters. Components. Application Guidelines Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters

More information

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation

More information

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

Technical Information

Technical Information Watt Density & Heater Selection - Guidelines Understanding Watt Density Watt density (W/in ) is the heat flux emanating from each square inch of the effective heating area (heated surface) of the element.

More information

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018 Installation and Operation Instructions Versa TM Screw Plug Oil & Water Immersion Heater 1 PD449-2 161-306451-003 January 2018 B 6" 1-13/16 Cold (Ref.) 9-1/8" 2-3/4 Min. Hole Size 6" 7-7/8" Thermowell

More information

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION EHB Series STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55

More information

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product Shown with optional bulkhead fittings Shown with optional mounting flange at end of sheath Design Features Copper brazed steel fins on steel sheath standard. Aluminum based protective coating available.

More information

Industrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM)

Industrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM) Company Presentation Dipl.-Ing. Wolfgang Vogler (GM) 1 Main Competence is recognised as a professional and competitive company in design and manufacture of electric process heaters and assosiated thyristor

More information

Flange immersion heaters

Flange immersion heaters Flange immersion heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS MAINTAINING A CONTINUOUS TEMPERATURE CETAL flange immersion heaters are designed and manufactured

More information

Industrial Flanged Immersion Heaters

Industrial Flanged Immersion Heaters Industrial Flanged Immersion Heaters Installation, Operation, and Maintenance Instructions 1.0 Handling 1.1 Unpack and handle with care to avoid damage to heater and components. Elements may come in contact

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

10-14 SECTION TUBULAR HEATERS

10-14 SECTION TUBULAR HEATERS Tubular Heater Specifications...10-2 Tubular Heater Terminations...10-4 Tubular Heater Mounting...10-5 Tubular Heater Moisture Seals...10-7 Standard Sizes and atings...10-8 Typical Bend Formations...10-10

More information

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH Dimensions (Inches) Rotatable Terminal Cover 1" Conduit Opening Outlet 1" FNPT Inlet 1" FNPT 1" FNPT Pipe Plug (or Inlet) Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION 6" 4" E1 4 (Supersedes

More information

Tubular Heaters. Table Of Contents

Tubular Heaters. Table Of Contents Table Of Contents Pictorial Index....................... A-24 Tubular Heater Introduction and Specifications..................... 10-2 Tubular Heater Terminations........... 10-4 Tubular Heater Mounting

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product Table Of Contents Pictorial Index....................... A-24 Tubular Heater Introduction and Specifications..................... 10-2 Tubular Heater Terminations........... 10-4 Tubular Heater Mounting

More information

W A T L O W. Straight Resistance Wire. Welded End Cap

W A T L O W. Straight Resistance Wire. Welded End Cap W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily

More information

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics

More information

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users. CAST-X 1 Circulation Heater With optional built-in controls, CAST-X 1 is a straightforward solution, perfect for OEMs and end users. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X Circulation

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

Installation, Operation and. Maintenance Instructions

Installation, Operation and. Maintenance Instructions Installation, Operation and Maintenance Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE (Supersedes Ogden Manual 35) JULY, 2004 K Series: Tubular Style Elements Industrial Flanged Immersion

More information

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage

More information

W A T L O W. Straight Resistance Wire. Welded End Cap

W A T L O W. Straight Resistance Wire. Welded End Cap W A T L O W The versatile Watlow cable heater can be formed to a variety of shapes as dictated by its many applications. Cable heaters are small diameter, high performance units, fully annealed and readily

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

WATLOW ELECTRIC MANUFACTURING COMPANY

WATLOW ELECTRIC MANUFACTURING COMPANY I&M MANUAL No: 316-42-8-1 Page: 1 General Statement The purpose of this product manual (the Manual ) is for Watlow Electric Manufacturing Company ( Watlow ) to convey certain recommendations, advisories,

More information

WATLOW ELECTRIC MANUFACTURING COMPANY

WATLOW ELECTRIC MANUFACTURING COMPANY I&M MANUAL No: 316-42-10-1 Page: 1 General Statement The purpose of this product manual (the Manual ) is for Watlow Electric Manufacturing Company ( Watlow ) to convey certain recommendations, advisories,

More information

Circulation Heaters - EX

Circulation Heaters - EX pplication irculation Heaters - RMOVL LN HTR SKT aloritech circulation heaters are suitable for use in forced flow and natural flow heating loops where a safe, lean, reliable, and efficient heating source

More information

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

! The Caution Symbol (exclamation point) alerts you to a CAUTION, a safety or I&M NUMBER: 316-42-10-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS MEGAWAT high-density cartridges are round tubular heaters with electrical terminations on one side. These dependable heaters are made to withstand tough industrial

More information

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications Temperatures up to 800 F (982 C) Precise temperature control Choice of lead orientation Built-in type J or K Thermocouple Round, square and rectangular cable Rugged, durable construction MIGHTYBAND The

More information

HotRod CARTRIDGE HEATERS

HotRod CARTRIDGE HEATERS HotRod CARTRIDGE HEATERS C A R T R I D G E H E A T E R S Same day shipment on 1000 s of models! TODAY HEA T E RS Made in USA ÂÂCONSTRUCTION...3 ÂÂStandard specifications...3 ÂÂWatt Density...4 ÂÂsheath

More information

Packaged Steam Fired Water Heater

Packaged Steam Fired Water Heater MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

Tubular Heaters and Heating Elements

Tubular Heaters and Heating Elements Tubular Heaters and Heating Elements Tubular Heaters Formed Tubular Heating Elements provide an economical, robust, and versatile heat source. Tubular Heating Elements are commonly used to fit into milled

More information

Nuclear Electric Heating

Nuclear Electric Heating Nuclear Electric Heating Caloritech has exceeded the most demanding nuclear heating requirements for over 30 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear

More information

W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS

W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS W A T L O W MULTICELL HEATERS MEET YOUR HIGHEST DEMANDS MULTICELL HEATERS......................... UNIQUE ADVANTAGES FOR DEMANDING OPERATIONS Sheath Temperature MULTICELL HEATERS: THE HIGH TEMPERATURE

More information

electric immersion heaters

electric immersion heaters C70-7 electric immersion heaters electric heating and controls Table Contents Selection Guide... - Quick Ship Pipe Thread Heaters... - Construction Features... Pipe Thread Heaters... -/ Pipe Thread Heaters...

More information

Cartridge Heaters. temperatures up to 450 C. heaters in difficult applications. 2. High impact ceramic cap retards HotRods are available in a wide

Cartridge Heaters. temperatures up to 450 C. heaters in difficult applications. 2. High impact ceramic cap retards HotRods are available in a wide HotRod Cartridge Heaters STANDARD The engineers at Marathon Heater have developed a cartridge heater that exceeds the performance and durability of other cartridge HOTROD heaters. Through refinements in

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SH and H HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659

More information

( )

( ) (1-800-492-8826) www.wattco.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies two types

More information

(770) wwww.southgateprocess.com

(770) wwww.southgateprocess.com (770) 345-0010 wwww.southgateprocess.com OVERVIEW WATTCO duct heaters are composed of open coil, tubular or finned tubular heating elements that are either flanged or inserted in the duct. WATTCO supplies

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters

Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters Coil Heaters Square, Mini Coil Heaters, Formable/Flexible Tubular Heaters National Plastic Heater, Sensor and Control Inc., is a leading

More information

electric immersion heaters

electric immersion heaters C70- electric immersion heaters electric heating and controls Introduction INDEECO designs and manufactures commercial and industrial electric heating and control systems that set the industry standard

More information

Finned Tubular Heaters

Finned Tubular Heaters Finned Tubular Heaters Finned Tubular Heating Elements Finned Tubular Heaters Finned Tubular Heating Elements are the most versatile, dependable and rugged of any heat generating device. These qualities

More information

COIL AND CABLE HEATERS. Mightyband Cable Heaters Tempco-Pak Cable Heaters

COIL AND CABLE HEATERS. Mightyband Cable Heaters Tempco-Pak Cable Heaters Mightyband Cable Heaters...5-2 Tempco-Pak Cable Heaters...5-0 Tempco Replacement Heaters for OEM Runnerless Molding Systems...5-4 SECTION COIL AND CABLE HEATERS Design Features Temperatures up to 800 F

More information

Tubular Heaters Series

Tubular Heaters Series Tubular Heaters Series Immersion Heaters, Tubular Heaters, Ribbed Tubular Heaters Screw-in Immersion Heater Standard sizes for application in water Power (W) 2000 000 4500 6000 7500 Input Voltage (V) 20

More information

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Tubular Industrial Process

Tubular Industrial Process Tubular Industrial Process Tubular Heater See Page 11-115 Silicone Rubber Heater Cabinet Tempco enclosure heaters are the answer to all your enclosure heater needs. Our heaters are designed to help electric,

More information

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers Sioux EN-Series All-Electric Steam Cleaners and Pressure Washers Sioux EN-Series All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers Model EN-270-H4-3000-XP When Performance and

More information

The CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater.

The CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater. CAST-X 25 Circulation Heater The CAST-X 25 is our most compact dual-tube model, a powerful and versatile mid-sized heater. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X heaters are

More information

Screwplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard

Screwplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard Screwplug Heaters Screwplug Heaters pplication Screwplug heaters are primarily used to heat liquids in tanks or vessels. To do so safely and reliably requires that the heating elements remain fully immersed

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

C1N & C2N SERIES Fluid heating for light industrial applications

C1N & C2N SERIES Fluid heating for light industrial applications Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options. CAST-X 2 Circulation Heater CAST-X 2 is a very versatile heater, with multiple housing, standoff, control and enclosure options. Designed and manufactured by Cast Aluminum Solutions (CAS), CAST-X Circulation

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Machining: Moderate to Extensive. Pattern Shop

Machining: Moderate to Extensive. Pattern Shop Casting Process: Low Pressure Used for large volume quantities. Specifically suited for intricate and challenging geometric shapes, producing quality castings with consistent dimensional accuracy and superior

More information