AIR HANDLER R-410A Refrigerant 2-5 Tons. Submittal Data English Language/IP Units SD1008HN 07/15
|
|
- Andra Moody
- 6 years ago
- Views:
Transcription
1 AI HANDLE -0A efrigerant - Tons Submittal Data English Language/IP Units SD00HN 0/
2 ontractor: ENVISIN AI HANDLE - Tons Model Nomenclature NAH 0 * 00 0 Model NAH Envision Series Air Handler Unit apacity efrigeration (DX) Models with Nominal FM 0 MBTUH 00 0 MBTUH 00 MBTUH 0 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH 0 Hydronic Models with Nominal FM 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH 0 Vintage * = Factory Use nly Air oil efrigerant H - Hydronic Motor EM 0-0/0/ Disconnect 0 No Breaker Installed (only on k & 0k Heaters) Breaker Installed (only on k & 0k Heaters) Electric Heat 00 None 0 k (0 0 only) 0 0k (00 00 only) k (0 00 only) 0 0k (00 only) ev.: 0 April 0D TE: To field convert the NAH0-00 to bottomflow air discharge, the NAHB kit must be ordered. ompatibility Air Handler Sizing Selection The Envision Air Handlers are designed for -0A refrigerant and should be matched with Series Split compressor section according to the table below. Air Handler Indoor Split Model (Single) Indoor Split Model (Dual apacity) utdoor Split Model (Dual apacity) Airflow(FM) Electric Heat (k) NAH0B*** NSZ0-00 NAH0B*** - NDZ0 NDS0 NAH00B*** NSZ , 0 NAH0B*** NSZ0 - -, 0 NAH0B*** - NDZ0 NDS0, 0 NAH0B*** NSZ , NAH0B*** NSZ , NAH0B*** - NDZ0 NDS0 0, NAH00B*** NSZ ,, 0 NAH00B*** - NDZ0 NDS0 0 0,, 0 NAH00B*** NSZ ,, 0 NAH00B*** - NDZ0 NDS0 0 0,, 0 //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
3 ontractor: ENVISIN AI HANDLE - Tons eneral Specifications efrigerant Air oil Designed for -0A refrigerant. onfigured as an A coil, rifled copper tubes and enhanced corrugated lanced aluminum fins to provide high efficiencies at low face velocities. Exclusive FormiShield TM coating for added protection. Hydronic Air oil Designed for hydronic applications. onfigured as an A coil, smooth copper tubes and enhanced corrugated lanced aluminum fins that provide increased performance. Exclusive FormiShield TM coating for added protection. Filter ack Integral filter rack holds in. or in. filters (field changeable). in. MEV disposable filter included. abinet (Encased Models) abinets are designed for upflow, horizontal, and bottomflow applications. onstructed of heavy gauge environmentally-responsible galvanized steel and finished with corrosion-resistant powder coating which meets ASTM B (,000 hour salt spray). Front access panel for ease of service. Insulation (Encased Models) The interior surfaces shall be lined with thick multidensity, cleanable aluminum foil coated glass fiber which meets NFPA 0A requirements, air erosion and mold growth limits of UL-, stringent fungal resistance test per ASTM-0 and ASTM, and zero level bacteria growth per ASTM. ontrols volt VA transformer, EM interface board allows for blower speed selection and thermostat inputs. Auxiliary/Emergency Heat ptional factory installed electric heat. k and 0 k heaters include circuit breakers. Drain Pans Two e-coated galvanized steel drain pans included, one for vertical and one for horizontal applications. The pans come equipped with primary and secondary drain connections. Expansion Device Factory installed TXV with internal check valve. The TXV is inside the cabinet on the encased models. efrigerant onnections Suction and liquid lines have sweat connections extended outside the cabinet on encased models for ease of connection. Hydronic onnections ater in and water out lines have sweat connections extended outside the cabinet on encased models for ease of connection. aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
4 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - DX Air Handlers Top Flow/Horizontal Unit onfiguration DD EE FF D HH II E K J L AA BB N M F JJ P Q S H I B LL MM T U V A Topflow/ verall abinet efrigerant/ater onnections Horizontal D E F onfiguration A B /" cond /" cond eturn H I J K L M N P Q S Power Low Air Duct Suction / Liquid / idth Depth Height Supply Voltage Flange ater ut ater In in cm HH II S T U V X Y Z AA BB DD EE FF " cond /" cond JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D. tube Discharge flange is field installed and extends " (. mm) from cabinet ev: // aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
5 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - DX Air Handlers Bottom Flow Unit onfiguration A X I B JJ T V U 0. F S KK LL MM H Y DD EE J K FF AA BB N M L D E P HH II Z Q verall abinet efrigerant/ater onnections Bottomflow D E F onfiguration A B /" cond " cond eturn H I J K L M N P Q 0-00 idth Depth Height Low Voltage Power Supply Air Duct Flange Suction / ater ut Liquid / ater In in cm DD EE S T U V X Y Z AA BB " cond /" cond FF HH II JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D. tube ev: // Discharge flange is field installed and extends " (. mm) from cabinet aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
6 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - Hydronic Air Handler Top Flow/Horizontal Unit onfiguration DD EE FF D HH II E K J L AA BB N M F JJ P Q S H I B LL MM T U V A Topflow/ verall abinet efrigerant/ater onnections Horizontal D E F onfiguration A B /" cond /" cond eturn H I J K L M N P Q S Power Low Air Duct Suction / Liquid / idth Depth Height Supply Voltage Flange ater ut ater In in cm HH II S T U V X Y Z AA BB DD EE FF " cond /" cond JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D Discharge flange is field installed and extends " (. mm) from cabinet ev: // aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
7 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - Hydronic Air Handler Bottom Flow Unit onfiguration A X I B JJ T U V 0. F S KK LL MM H Y DD EE J K FF AA BB N M L D E P HH II Z Q verall abinet efrigerant/ater onnections Bottomflow D E F onfiguration A B /" cond " cond eturn H I J K L M N P Q 0-00 idth Depth Height Low Voltage Power Supply Air Duct Flange Suction / ater ut Liquid / ater In in cm DD EE S T U V X Y Z AA BB " cond /" cond FF HH II JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D ev: // Discharge flange is field installed and extends " (. mm) from cabinet aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
8 ontractor: ENVISIN AI HANDLE - Tons Pressure Drop ater Pressure Drop - Hydronic oil Flow Pressure Drop (PSI) gpm 0 F 0 F 0 F 00 F 0 F 0 F 0 F Blower Performance Blower Performance Variable Speed EM Model Max ESP (wg) Blower Motor (hp) HP FM Setting Normal Mode Htg & lg Dehumidification Mode lg Aux FM Setting Aux Emerg S S Stg Stg Blower S Stg Stg Blower S S Mode 0.0 / n n ff 00 0 n n / ff n ff ff n / n ff 00 0 ff 00 0 n ff 0.0 / ff ff ff ff / n n ff 0 00 n n / ff n ff 0 0 ff n / n ff 00 ff 0 0 n ff 0.0 / ff ff 0 00 ff ff 0.0 / n n ff 00 n n / ff n ff 0 00 ff n / n ff ff n ff 0.0 / ff ff 00 0 ff ff / n n ff 0 0 n n / ff n 0 ff 0 0 ff n / n ff ff n ff 0.0 / ff ff ff ff n n ff n n ff n 00 0 ff ff n 0 0. n ff 00 ff n ff ff ff 0 0 ff ff 0. n n ff n n ff n 0 ff 0 0 ff n 0 0. n ff ff n ff 0. ff ff ff ff n n 0 0 ff 0 0 n n ff n 0 00 ff ff n 0 0. n ff 0 0 ff 00 0 n ff 0. ff ff 0 ff ff 00 Factory FM settings are in boldface //0 FM is controlled within % up to maximum ESP S Maximum ESP includes allowance for wet coil and standard filter ff n DIP switch must be 'FF' to select dehumidification mode 0 Heating and ooling Auxiliary Heating Dehumidification aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
9 ontractor: ENVISIN AI HANDLE - Tons Physical haracteristics Air Handler Model Number (efrigerant) Air oil Total Face Area, ft [m] Tube outside diameter - in. [mm] Evaporator Number of rows oil Fins per inch Suction line connection - in. [mm] sweat Liquid line connection - in. [mm] sweat efrigerant NAH0 NAH0 NAH00 NAH0 NAH0 NAH0 NAH00. [0.] / [.] / [.] / [.] / [.] -0a Nominal cooling capacity - tons [k]. [.]. [.]. [.] [0.]. [.0] [.0] [.] ondensate drain connection - (.D.) in. [mm] / [.0] Blower heel Size (Dia x ), in. [mm] Blower motor type/speeds x 0 [ x ] Variable Speed EM Blower motor output - hp [] / [] [] Filter Standard - " [mm] MEV disposable, in. [mm] Electrical characteristics (0hz) 0 x [0 x ] 0/0 - ph Shipping weight - lbs. [kg] perating weight - lbs. [kg] [.] [.] 0 [.] 00 [0.] // Air Handler Model Number (Hydronic) NAH0 NAH0 NAH0 NAH00 Air oil Total Face Area, ft [m] Tube outside diameter - in. [mm]. [0.] / [.] Hydronic oil Number of rows Fins per inch ater In connection - in. [mm] sweat ater ut connection - in. [mm] sweat / [.] / [.] Nominal cooling capacity - tons [k]. [.] [0.] [.0] [.] ondensate drain connection - (.D) in. [mm] Blower heel Size (Dia x ), in. [mm] Blower motor type/speeds / [.0] x 0 [ x ] Variable Speed EM Blower motor output - hp [] / [] [] Filter Standard - " [mm] MEV disposable, in. [mm] Electrical characteristics (0hz) Shipping weight - lbs. [kg] perating weight - lbs. [kg] 0 x [0 x ] 0/0 - ph 0 [.] 00 [0.] TE: ater connection dimensions are.d. //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
10 ontractor: ENVISIN AI HANDLE - Tons Electrical Data Model Electric Heat apacity Aux. Heat Supply Minimum ated Voltage Voltage Heater Minimum ircuit Maximum Fuse/ Blower Total Unit FLA Ampacity Ampacity HA K BTUH ircuit Min/Max Motor FLA FM 0v 0v 0v 0v 0v 0v 0v 0v 0v 0v , single , single , single , single , single , single , single , single , L/L, /0/ / L/L , single , single , L/L, L/L , single , single , L/L, L/L ,0 single ,0 //0 L/L, L/L ated Voltage of 0/0/0/ HA circuit breaker in USA only Low Voltage Point to Point iring To Air Handler From Thermostat To ompressor Section Y Y Y Y Y Y L L Air Handler transformer must be VA. //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ 0 Page of
11 ontractor: ENVISIN AI HANDLE - Tons iring Schematics Air Handler iring Schematic - 0-0/0/ P-0 TS L Factory Low voltage wiring Factory Line voltage wiring Field low voltage wiring Field line voltage wiring ptional block D Voltage PB traces Internal junction Quick connect terminal Thermal Limit Switch Field wire lug round N.., N.. E to E - Aux heat stage relays Legend P Notes: To operate in 0V mode replace the blue transformer wire connected to PB-L with red transformer wire. Jumper wires are Factory Installed, and are needed for electric heat operation. Dip switches are used to select the air flow. Use manufacturer s part number P-0 (jumper bar assembly) when single source power is required. Low voltage wiring LASS. EH EH PB - S - HE - Light emitting diode - reen 0-0V elay coil Electric Heat ontactor Polarized connector Power block DIP package 0 position Heater element Breaker Dual Power Supply onnections If two separate circuits are used to supply power to the auxiliary heat kit, the Installer will need to verify that each leg of the auxiliary heat circuit breakers are wired from the power supply correctly in order for the electric heat kit to operate properly. This can be done by measuring the supply side voltage of the auxiliary heat circuit breakers. Put a voltmeter on the L side of ircuit Breaker ne and on the L side of ircuit Breaker Two. The voltmeter should read approximately 0 volts. If the meter reads high voltage, the auxiliary heat breakers need to be rewired so that breakers in the auxiliary heat kit match the wiring of the Disconnect Panel breakers. Meaning, L and L from one breaker in the disconnect panel must connect to L and L at one of the auxiliary heat circuit breakers and L and L from the other breaker in the disconnect panel must connect to L and L of the other auxiliary heat circuit breaker, making sure that the L and L from each disconnect breaker matches the L and L at each of the auxiliary heat breakers. Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black Blue ed TE Note 0 S n 0-0/0/ L LED Air Handler No Electric Heat PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range 0 rn PM grnd PM BK L ADJUST HEAT DELAY Y Y /Y n/ff / EM / EM Blower Motor aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
12 ontractor: ENVISIN AI HANDLE - Tons iring Schematics cont. 0-0/0/ PB Transformer Black L L ry() ry() Yel V Blk/h ed TE Blue Brown range rn rn() Thermostat Y Y rn/yel() XFM SE P DD Y Y LED Note 0 S n P 0 Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () 0 PM grnd PM L ADJUST HEAT DELAY BK Y Y /Y n/ff / EM / ray E E TE P E E P ry() ry() HE TS /B EM Blower Motor ht() Air Handler k Electric Heat rn() Electric Heat 0-0/0/ Yel V Transformer Blk/h Black ed TE Blue L PB L Brown range ry() Yel() rn ry() Yel() rn() Thermostat Y Y rn/yel() XFM SE P DD Y Y /B LED Note 0 S n P 0 Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () 0 PM BK n/ff PM grnd L ADJUST HEAT DELAY Y Y /Y / EM / EM Blower Motor TE P ht(0) Blu() ray E E E E P ry() HE ry() Yel() HE Yel() TS TS ht() TD Air Handler 0k Electric Heat rn() Electric Heat aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
13 ontractor: ENVISIN AI HANDLE - Tons iring Schematics cont. 0-0/0/ ircuit 0-0/0/ ircuit Note L L L L rn() Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black ed TE Blue L Note 0 S n LED PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range ed () Black() Air Handler w/ k Electric Heat 0 rn PM grnd PM L ADJUST HEAT DELAY BK Y Y /Y n/ff / EM / EM Blower Motor ht() rn() P TE TD BK Blk() Yel() ht(0) BK ry() ray E ry() Blu EH E Blu() E E P Blk() ry(0) Yel() Blk() Yel() Blu HE HE HE EH TS TS TS Electric Heat ry() Blk() Yel() 0-0/0/ ircuit 0-0/0/ ircuit Note L L L L rn() Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black ed TE Blue L LED Note 0 S n PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range ed () Black() Air Handler w/ 0k Electric Heat 0 rn PM BK PM grnd L ADJUST HEAT DELAY Y Y /Y n/ff / EM / EM Blower Motor ht() rn() P TE TD BK Blk() Yel() Pnk() ht(0) Blu() BK P Blk() ry(0) Yel() Pnk() ry() ray E ry() Blu EH E E E Blk() Yel() Blu Pnk() HE HE HE HE EH TS TS TS TS Electric Heat ry() Blk() Yel() PNK() aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
14 ontractor: ENVISIN AI HANDLE - Tons Engineering uide Specifications eneral The air handler shall provide vertical upflow, downflow, or horizontal configurations in one package. Units shall be listed by a nationally recognized safety-testing laboratory or agency, such as Underwriter s Laboratory (UL) or Environmental Testing Laboratories (Intertek-ETL). The air handler units shall be designed and AHI performance listed to operate with the Series geothermal split condensing units as provided by aterfurnace, International of Fort ayne, Indiana. Each unit shall be pallet mounted and shipped using dense cardboard corners/top and stretch wrap for easy shipping damage inspection. asing and abinet The cabinet shall be fabricated from heavy-gauge galvanized steel and polyester powder coat paint to withstand 000 hours of salt spray testing. The interior shall be insulated with in. thick, multi-density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges to prevent the introduction of glass fibers into the discharge air. ne large blower compartment access panel shall be provided and shall be removable with supply and return ductwork in place. The internal components layout shall provide for major service with the unit in-place for restricted access installations. The blower assembly access shall be slide-out serviceable via a works-in-a-drawer design. The cabinet shall be convertible to horizontal or downflow applications by reconfiguring the cabinet using only a nut driver. The unit shall be zero clearance approved on any of its surfaces. The cabinet shall be divided into two cubes to facilitate easy transport up attic ladders when needed. Standard-size MEV in. filters shall be provided with each unit. Blower Motor and Assembly The blower shall be an oversized direct drive centrifugal type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low outlet velocity operation and of galvanized or galvalume steel construction. Tight blower housing geometry shall not be permitted. The blower housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the blower motor through a works-in-a-drawer design. The high efficiency blower motor shall be a variable speed EM type. The blower motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated ball bearings and have thermal overload protection. Electrical A solid state electronic control module shall be provided for the control of the blower and each stage of electric heat. Single or dual circuit line voltage terminal blocks shall be provided for the air handler power supply. Fuse protection shall be provided for the VA control transformer. Units shall have knockouts for entrance of the low and line voltage wiring. The blower motor shall incorporate a harness plug-connection for easy removal. An integral circuit breaker shall be provided on all units employing or 0k electric heat. The control shall maintain the blower operation 0 seconds after the compressor or electric heat have shut off to improve efficiency. Piping efrigerant connections shall be made using sweat copper joints. The condensate connections shall be a / in..d. tube. efrigeration ircuit All units shall provide a fin tube air-to-refrigerant heat exchanger of the A coil design. The finned tube coil shall be sized for low-face velocity and constructed of lanced aluminum fins bonded to rifled copper tubes in a staggered pattern. The coil shall include an integral corrosion resistant e-coated galvanized drain pan. The thermal expansion valve shall be factory installed and provide proper superheat over the entire liquid temperature range with minimal hunting. The valve shall operate in the cooling mode through the use of an internal check valve. aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
15 ontractor: ENVISIN AI HANDLE - Tons evision uide Pages: Description: Date: By: - Updated iring Schematics 0 April 0 MA -, Updated Hydronic Data Aug 0 MA,,, Updated Drain Pan 0 May 0 DS/MA All Updated Dimensional Data for New Vertical ondensate Drain 0 May 0 DS All Updated Nomenclature For New EM Motor 0 Feb 0 DS Added evision uide 0 Feb 0 DS aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of
NAH Series HYDRONIC AIR HANDLER 2 TO 5 TONS. Submittal Data English Language IP/Metric Units SD1028HG1 05/17
HYDNI AI HANDLE T TNS Submittal Data English Language IP/Metric Units SD0H 0/ ontractor: Model Nomenclature - Tons 0Hz - - - 0 NAH 0 * 00 0 H Model NAH Unit apacityacity 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH
More informationEnvision Air Handler Specification Catalog
Air Handler Design Features Factory ptions Accessories Dimensional Data Physical Data Performance Data Engineering uide Specifications Envision Air Handler Specification atalog S00HN 0/ ENVISIN AI HANDLE
More informationSPECIFICATION CATALOG
SPEIFIATIN ATAL ETHEMAL HEAT PUMPS AFFDABLE ENEWABLE LEAN ASTN SEIES AI HANDLE ASTN SEIES AI HANDLE SPEIFIATIN ATAL Table of ontents Air Handler Nomenclature...........................................................
More informationNAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections
NAH Series Air Handler Installation Information Water Piping onnections Electrical onnections Startup Procedures Preventive Maintenance NAH Series Hydronic Air Handler Installation Manual IM0H 0/ NAH
More informationINSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES AIR HANDLER GEOTHERMAL HEAT PUMPS
INSTALLATION MANUAL EOTHEMAL HEAT PUMPS AFFODABLE ENEWABLE LEAN ASTON SEIES AI HANDLE Table of ontents Model Nomenclature.............................................................. Initial Inspection..................................................................
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More information36,000-62,000 BTUH Nominal Capacity
36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationThe Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationCWA4 Chilled & Hot Water Fan Coil
CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump
More informationCWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH
CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal
More informationMX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat
SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationDH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil
DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationGEOTHERMAL/WATER SOURCE OUTDOOR SPLIT HEAT PUMP 2 TO 6 TONS DUAL CAPACITY SPECIFICATION CATALOG
GEOTHEMAL/WATE SOUE OUTDOO SPLIT HEAT PUMP TO 6 TONS DUAL APAITY SPEIFIATION ATALOG Table of ontents Model Nomenclature.... AHI Data... 6- Design Features... 8 NDS Split Features... 9 Physical Data...
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationT-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS
PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A 2/4TEC3F42C1000A 2/4TEC3F48B1000A 2/4TEC3F55B1000A 2/4TEC3F60B1000A 1½ 5 Ton PUB. NO. 22-1774-17
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationB24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)
ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400
More informationTECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)
TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More information2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½
Cooling/Heat Pump Convertible Air Handlers 2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½ 5 Ton Preliminary PUB. NO. 22-1777-04 Features and
More informationTechnical Data Manual Model Nos. and pricing: see Price List
Technical Data Manual Model Nos. and pricing: see Price List Viessmann AirflowPLUS AH2A series Hydronic forced air handler Viessmann AirflowPLUS Product may not be exactly as shown Viessmann AirflowPLUS
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile
More informationCROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25
More informationRuud Standard Efficiency Air Handler
Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationWH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3
FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides
More informationRuud Standard Efficiency Air Handler
Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS
DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationRheem High Efficiency Modulating EcoNet Enabled Air Handler
Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows
More informationCondensing Units & Air Handlers
Condensing Units & Air Handlers 13 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice. Copyright
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationEC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons
E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any
More informationTECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES
TP TECH GUIDE TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP 1200-2000 CFM BLOWERS 3-5 TON COILS OPTIONAL ELECTRIC HEATERS ISO 9001 Certified
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationRheem Standard Efficiency Air Handler
Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More information700A11. Geothermal Heat Pump 3-5 ton (variable speed) Submittal Data English Language/IP Units SD2700AN 12/17
700A eothermal Heat Pump -5 ton (variable speed) Submittal Data English Language/IP Units SD700AN /7 ontractor: 7 Series 700A Model Nomenclature -6 7 8 9 0 5 N V V 06 * 0 L 0 J 6 N Model N 7 series Water-to-Air
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal
More informationRheem High Efficiency Two-Stage EcoNet Enabled Air Handler
Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate
More informationGreensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com
Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationRheem High Efficiency Two-Stage EcoNet Enabled Air Handler
Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationGuide Specifications PART 1 GENERAL 1.01 SUMMARY
Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control
More informationAIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant
FORM NO. H11-527 REV. 5 Supersedes Form No. H11-527 Rev. 4 AIR HANDLERS (Model with Coil) AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant earth friendly
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationSPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning
SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationPGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT
PGB SERIES 3thru5Ton 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed
More informationSPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning
SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationPGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT
PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed
More informationRheem Air Handlers. RHML- Series X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6
More informationHIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER
FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationCFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH
CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationVersatec Base Series Installation Manual
ommercial 0.5 to 6 Ton eothermal/water Source Heat Pump Installation Information Water Piping onnections Electrical Startup Procedures Troubleshooting Versatec Base Series Installation Manual Preventive
More informationTECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series
Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used
More informationUpflow/Downflow A-Coil Specifications
June 2013 Upflow/Downflow A-Coil Specifications ADP Model # Width Depth Height Pallet Qty. Coil Weight (lbs) C36A142(*)126 14.25" 21" 16.5" 12 38 1200 386.36 C36A175(*)126 17.50" 21" 16.5" 8 40 1200 386.34
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BVA Product Specifications Data subject to change 12.2016 Bosch Thermotechnology Corp. Product Specifications
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Industry Standard R-410A Refrigerant also Suitable for R-22 Applications Models featuring Electric
More informationVertical Upflow Horizontal Left Air Handlers
Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with
More information