1 AI HANDLE -0A efrigerant - Tons Submittal Data English Language/IP Units SD00HN 0/

2 ontractor: ENVISIN AI HANDLE - Tons Model Nomenclature NAH 0 * 00 0 Model NAH Envision Series Air Handler Unit apacity efrigeration (DX) Models with Nominal FM 0 MBTUH 00 0 MBTUH 00 MBTUH 0 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH 0 Hydronic Models with Nominal FM 0 MBTUH 0 MBTUH 0 MBTUH 00 MBTUH 0 Vintage * = Factory Use nly Air oil efrigerant H - Hydronic Motor EM 0-0/0/ Disconnect 0 No Breaker Installed (only on k & 0k Heaters) Breaker Installed (only on k & 0k Heaters) Electric Heat 00 None 0 k (0 0 only) 0 0k (00 00 only) k (0 00 only) 0 0k (00 only) ev.: 0 April 0D TE: To field convert the NAH0-00 to bottomflow air discharge, the NAHB kit must be ordered. ompatibility Air Handler Sizing Selection The Envision Air Handlers are designed for -0A refrigerant and should be matched with Series Split compressor section according to the table below. Air Handler Indoor Split Model (Single) Indoor Split Model (Dual apacity) utdoor Split Model (Dual apacity) Airflow(FM) Electric Heat (k) NAH0B*** NSZ0-00 NAH0B*** - NDZ0 NDS0 NAH00B*** NSZ , 0 NAH0B*** NSZ0 - -, 0 NAH0B*** - NDZ0 NDS0, 0 NAH0B*** NSZ , NAH0B*** NSZ , NAH0B*** - NDZ0 NDS0 0, NAH00B*** NSZ ,, 0 NAH00B*** - NDZ0 NDS0 0 0,, 0 NAH00B*** NSZ ,, 0 NAH00B*** - NDZ0 NDS0 0 0,, 0 //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

3 ontractor: ENVISIN AI HANDLE - Tons eneral Specifications efrigerant Air oil Designed for -0A refrigerant. onfigured as an A coil, rifled copper tubes and enhanced corrugated lanced aluminum fins to provide high efficiencies at low face velocities. Exclusive FormiShield TM coating for added protection. Hydronic Air oil Designed for hydronic applications. onfigured as an A coil, smooth copper tubes and enhanced corrugated lanced aluminum fins that provide increased performance. Exclusive FormiShield TM coating for added protection. Filter ack Integral filter rack holds in. or in. filters (field changeable). in. MEV disposable filter included. abinet (Encased Models) abinets are designed for upflow, horizontal, and bottomflow applications. onstructed of heavy gauge environmentally-responsible galvanized steel and finished with corrosion-resistant powder coating which meets ASTM B (,000 hour salt spray). Front access panel for ease of service. Insulation (Encased Models) The interior surfaces shall be lined with thick multidensity, cleanable aluminum foil coated glass fiber which meets NFPA 0A requirements, air erosion and mold growth limits of UL-, stringent fungal resistance test per ASTM-0 and ASTM, and zero level bacteria growth per ASTM. ontrols volt VA transformer, EM interface board allows for blower speed selection and thermostat inputs. Auxiliary/Emergency Heat ptional factory installed electric heat. k and 0 k heaters include circuit breakers. Drain Pans Two e-coated galvanized steel drain pans included, one for vertical and one for horizontal applications. The pans come equipped with primary and secondary drain connections. Expansion Device Factory installed TXV with internal check valve. The TXV is inside the cabinet on the encased models. efrigerant onnections Suction and liquid lines have sweat connections extended outside the cabinet on encased models for ease of connection. Hydronic onnections ater in and water out lines have sweat connections extended outside the cabinet on encased models for ease of connection. aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

4 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - DX Air Handlers Top Flow/Horizontal Unit onfiguration DD EE FF D HH II E K J L AA BB N M F JJ P Q S H I B LL MM T U V A Topflow/ verall abinet efrigerant/ater onnections Horizontal D E F onfiguration A B /" cond /" cond eturn H I J K L M N P Q S Power Low Air Duct Suction / Liquid / idth Depth Height Supply Voltage Flange ater ut ater In in cm HH II S T U V X Y Z AA BB DD EE FF " cond /" cond JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D. tube Discharge flange is field installed and extends " (. mm) from cabinet ev: // aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

5 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - DX Air Handlers Bottom Flow Unit onfiguration A X I B JJ T V U 0. F S KK LL MM H Y DD EE J K FF AA BB N M L D E P HH II Z Q verall abinet efrigerant/ater onnections Bottomflow D E F onfiguration A B /" cond " cond eturn H I J K L M N P Q 0-00 idth Depth Height Low Voltage Power Supply Air Duct Flange Suction / ater ut Liquid / ater In in cm DD EE S T U V X Y Z AA BB " cond /" cond FF HH II JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D. tube ev: // Discharge flange is field installed and extends " (. mm) from cabinet aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

6 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - Hydronic Air Handler Top Flow/Horizontal Unit onfiguration DD EE FF D HH II E K J L AA BB N M F JJ P Q S H I B LL MM T U V A Topflow/ verall abinet efrigerant/ater onnections Horizontal D E F onfiguration A B /" cond /" cond eturn H I J K L M N P Q S Power Low Air Duct Suction / Liquid / idth Depth Height Supply Voltage Flange ater ut ater In in cm HH II S T U V X Y Z AA BB DD EE FF " cond /" cond JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D Discharge flange is field installed and extends " (. mm) from cabinet ev: // aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

7 ontractor: ENVISIN AI HANDLE - Tons Dimensional Data - Hydronic Air Handler Bottom Flow Unit onfiguration A X I B JJ T U V 0. F S KK LL MM H Y DD EE J K FF AA BB N M L D E P HH II Z Q verall abinet efrigerant/ater onnections Bottomflow D E F onfiguration A B /" cond " cond eturn H I J K L M N P Q 0-00 idth Depth Height Low Voltage Power Supply Air Duct Flange Suction / ater ut Liquid / ater In in cm DD EE S T U V X Y Z AA BB " cond /" cond FF HH II JJ KK LL MM Power Supply Low Voltage ondensate is stainless steel /".D ev: // Discharge flange is field installed and extends " (. mm) from cabinet aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

8 ontractor: ENVISIN AI HANDLE - Tons Pressure Drop ater Pressure Drop - Hydronic oil Flow Pressure Drop (PSI) gpm 0 F 0 F 0 F 00 F 0 F 0 F 0 F Blower Performance Blower Performance Variable Speed EM Model Max ESP (wg) Blower Motor (hp) HP FM Setting Normal Mode Htg & lg Dehumidification Mode lg Aux FM Setting Aux Emerg S S Stg Stg Blower S Stg Stg Blower S S Mode 0.0 / n n ff 00 0 n n / ff n ff ff n / n ff 00 0 ff 00 0 n ff 0.0 / ff ff ff ff / n n ff 0 00 n n / ff n ff 0 0 ff n / n ff 00 ff 0 0 n ff 0.0 / ff ff 0 00 ff ff 0.0 / n n ff 00 n n / ff n ff 0 00 ff n / n ff ff n ff 0.0 / ff ff 00 0 ff ff / n n ff 0 0 n n / ff n 0 ff 0 0 ff n / n ff ff n ff 0.0 / ff ff ff ff n n ff n n ff n 00 0 ff ff n 0 0. n ff 00 ff n ff ff ff 0 0 ff ff 0. n n ff n n ff n 0 ff 0 0 ff n 0 0. n ff ff n ff 0. ff ff ff ff n n 0 0 ff 0 0 n n ff n 0 00 ff ff n 0 0. n ff 0 0 ff 00 0 n ff 0. ff ff 0 ff ff 00 Factory FM settings are in boldface //0 FM is controlled within % up to maximum ESP S Maximum ESP includes allowance for wet coil and standard filter ff n DIP switch must be 'FF' to select dehumidification mode 0 Heating and ooling Auxiliary Heating Dehumidification aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

9 ontractor: ENVISIN AI HANDLE - Tons Physical haracteristics Air Handler Model Number (efrigerant) Air oil Total Face Area, ft [m] Tube outside diameter - in. [mm] Evaporator Number of rows oil Fins per inch Suction line connection - in. [mm] sweat Liquid line connection - in. [mm] sweat efrigerant NAH0 NAH0 NAH00 NAH0 NAH0 NAH0 NAH00. [0.] / [.] / [.] / [.] / [.] -0a Nominal cooling capacity - tons [k]. [.]. [.]. [.] [0.]. [.0] [.0] [.] ondensate drain connection - (.D.) in. [mm] / [.0] Blower heel Size (Dia x ), in. [mm] Blower motor type/speeds x 0 [ x ] Variable Speed EM Blower motor output - hp [] / [] [] Filter Standard - " [mm] MEV disposable, in. [mm] Electrical characteristics (0hz) 0 x [0 x ] 0/0 - ph Shipping weight - lbs. [kg] perating weight - lbs. [kg] [.] [.] 0 [.] 00 [0.] // Air Handler Model Number (Hydronic) NAH0 NAH0 NAH0 NAH00 Air oil Total Face Area, ft [m] Tube outside diameter - in. [mm]. [0.] / [.] Hydronic oil Number of rows Fins per inch ater In connection - in. [mm] sweat ater ut connection - in. [mm] sweat / [.] / [.] Nominal cooling capacity - tons [k]. [.] [0.] [.0] [.] ondensate drain connection - (.D) in. [mm] Blower heel Size (Dia x ), in. [mm] Blower motor type/speeds / [.0] x 0 [ x ] Variable Speed EM Blower motor output - hp [] / [] [] Filter Standard - " [mm] MEV disposable, in. [mm] Electrical characteristics (0hz) Shipping weight - lbs. [kg] perating weight - lbs. [kg] 0 x [0 x ] 0/0 - ph 0 [.] 00 [0.] TE: ater connection dimensions are.d. //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

10 ontractor: ENVISIN AI HANDLE - Tons Electrical Data Model Electric Heat apacity Aux. Heat Supply Minimum ated Voltage Voltage Heater Minimum ircuit Maximum Fuse/ Blower Total Unit FLA Ampacity Ampacity HA K BTUH ircuit Min/Max Motor FLA FM 0v 0v 0v 0v 0v 0v 0v 0v 0v 0v , single , single , single , single , single , single , single , single , L/L, /0/ / L/L , single , single , L/L, L/L , single , single , L/L, L/L ,0 single ,0 //0 L/L, L/L ated Voltage of 0/0/0/ HA circuit breaker in USA only Low Voltage Point to Point iring To Air Handler From Thermostat To ompressor Section Y Y Y Y Y Y L L Air Handler transformer must be VA. //0 aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ 0 Page of

11 ontractor: ENVISIN AI HANDLE - Tons iring Schematics Air Handler iring Schematic - 0-0/0/ P-0 TS L Factory Low voltage wiring Factory Line voltage wiring Field low voltage wiring Field line voltage wiring ptional block D Voltage PB traces Internal junction Quick connect terminal Thermal Limit Switch Field wire lug round N.., N.. E to E - Aux heat stage relays Legend P Notes: To operate in 0V mode replace the blue transformer wire connected to PB-L with red transformer wire. Jumper wires are Factory Installed, and are needed for electric heat operation. Dip switches are used to select the air flow. Use manufacturer s part number P-0 (jumper bar assembly) when single source power is required. Low voltage wiring LASS. EH EH PB - S - HE - Light emitting diode - reen 0-0V elay coil Electric Heat ontactor Polarized connector Power block DIP package 0 position Heater element Breaker Dual Power Supply onnections If two separate circuits are used to supply power to the auxiliary heat kit, the Installer will need to verify that each leg of the auxiliary heat circuit breakers are wired from the power supply correctly in order for the electric heat kit to operate properly. This can be done by measuring the supply side voltage of the auxiliary heat circuit breakers. Put a voltmeter on the L side of ircuit Breaker ne and on the L side of ircuit Breaker Two. The voltmeter should read approximately 0 volts. If the meter reads high voltage, the auxiliary heat breakers need to be rewired so that breakers in the auxiliary heat kit match the wiring of the Disconnect Panel breakers. Meaning, L and L from one breaker in the disconnect panel must connect to L and L at one of the auxiliary heat circuit breakers and L and L from the other breaker in the disconnect panel must connect to L and L of the other auxiliary heat circuit breaker, making sure that the L and L from each disconnect breaker matches the L and L at each of the auxiliary heat breakers. Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black Blue ed TE Note 0 S n 0-0/0/ L LED Air Handler No Electric Heat PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range 0 rn PM grnd PM BK L ADJUST HEAT DELAY Y Y /Y n/ff / EM / EM Blower Motor aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

12 ontractor: ENVISIN AI HANDLE - Tons iring Schematics cont. 0-0/0/ PB Transformer Black L L ry() ry() Yel V Blk/h ed TE Blue Brown range rn rn() Thermostat Y Y rn/yel() XFM SE P DD Y Y LED Note 0 S n P 0 Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () 0 PM grnd PM L ADJUST HEAT DELAY BK Y Y /Y n/ff / EM / ray E E TE P E E P ry() ry() HE TS /B EM Blower Motor ht() Air Handler k Electric Heat rn() Electric Heat 0-0/0/ Yel V Transformer Blk/h Black ed TE Blue L PB L Brown range ry() Yel() rn ry() Yel() rn() Thermostat Y Y rn/yel() XFM SE P DD Y Y /B LED Note 0 S n P 0 Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () 0 PM BK n/ff PM grnd L ADJUST HEAT DELAY Y Y /Y / EM / EM Blower Motor TE P ht(0) Blu() ray E E E E P ry() HE ry() Yel() HE Yel() TS TS ht() TD Air Handler 0k Electric Heat rn() Electric Heat aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

13 ontractor: ENVISIN AI HANDLE - Tons iring Schematics cont. 0-0/0/ ircuit 0-0/0/ ircuit Note L L L L rn() Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black ed TE Blue L Note 0 S n LED PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range ed () Black() Air Handler w/ k Electric Heat 0 rn PM grnd PM L ADJUST HEAT DELAY BK Y Y /Y n/ff / EM / EM Blower Motor ht() rn() P TE TD BK Blk() Yel() ht(0) BK ry() ray E ry() Blu EH E Blu() E E P Blk() ry(0) Yel() Blk() Yel() Blu HE HE HE EH TS TS TS Electric Heat ry() Blk() Yel() 0-0/0/ ircuit 0-0/0/ ircuit Note L L L L rn() Yel Thermostat Y Y rn/yel() V Transformer Blk/h XFM SE P DD Y Y /B Black ed TE Blue L LED Note 0 S n PB L 0 P Black () Black () Black () Black () Black () Black () Black () Black () Black () Black (0) Black () Black () Black () Black () Black () Black () Brown range ed () Black() Air Handler w/ 0k Electric Heat 0 rn PM BK PM grnd L ADJUST HEAT DELAY Y Y /Y n/ff / EM / EM Blower Motor ht() rn() P TE TD BK Blk() Yel() Pnk() ht(0) Blu() BK P Blk() ry(0) Yel() Pnk() ry() ray E ry() Blu EH E E E Blk() Yel() Blu Pnk() HE HE HE HE EH TS TS TS TS Electric Heat ry() Blk() Yel() PNK() aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

14 ontractor: ENVISIN AI HANDLE - Tons Engineering uide Specifications eneral The air handler shall provide vertical upflow, downflow, or horizontal configurations in one package. Units shall be listed by a nationally recognized safety-testing laboratory or agency, such as Underwriter s Laboratory (UL) or Environmental Testing Laboratories (Intertek-ETL). The air handler units shall be designed and AHI performance listed to operate with the Series geothermal split condensing units as provided by aterfurnace, International of Fort ayne, Indiana. Each unit shall be pallet mounted and shipped using dense cardboard corners/top and stretch wrap for easy shipping damage inspection. asing and abinet The cabinet shall be fabricated from heavy-gauge galvanized steel and polyester powder coat paint to withstand 000 hours of salt spray testing. The interior shall be insulated with in. thick, multi-density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges to prevent the introduction of glass fibers into the discharge air. ne large blower compartment access panel shall be provided and shall be removable with supply and return ductwork in place. The internal components layout shall provide for major service with the unit in-place for restricted access installations. The blower assembly access shall be slide-out serviceable via a works-in-a-drawer design. The cabinet shall be convertible to horizontal or downflow applications by reconfiguring the cabinet using only a nut driver. The unit shall be zero clearance approved on any of its surfaces. The cabinet shall be divided into two cubes to facilitate easy transport up attic ladders when needed. Standard-size MEV in. filters shall be provided with each unit. Blower Motor and Assembly The blower shall be an oversized direct drive centrifugal type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low outlet velocity operation and of galvanized or galvalume steel construction. Tight blower housing geometry shall not be permitted. The blower housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the blower motor through a works-in-a-drawer design. The high efficiency blower motor shall be a variable speed EM type. The blower motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated ball bearings and have thermal overload protection. Electrical A solid state electronic control module shall be provided for the control of the blower and each stage of electric heat. Single or dual circuit line voltage terminal blocks shall be provided for the air handler power supply. Fuse protection shall be provided for the VA control transformer. Units shall have knockouts for entrance of the low and line voltage wiring. The blower motor shall incorporate a harness plug-connection for easy removal. An integral circuit breaker shall be provided on all units employing or 0k electric heat. The control shall maintain the blower operation 0 seconds after the compressor or electric heat have shut off to improve efficiency. Piping efrigerant connections shall be made using sweat copper joints. The condensate connections shall be a / in..d. tube. efrigeration ircuit All units shall provide a fin tube air-to-refrigerant heat exchanger of the A coil design. The finned tube coil shall be sized for low-face velocity and constructed of lanced aluminum fins bonded to rifled copper tubes in a staggered pattern. The coil shall include an integral corrosion resistant e-coated galvanized drain pan. The thermal expansion valve shall be factory installed and provide proper superheat over the entire liquid temperature range with minimal hunting. The valve shall operate in the cooling mode through the use of an internal check valve. aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

15 ontractor: ENVISIN AI HANDLE - Tons evision uide Pages: Description: Date: By: - Updated iring Schematics 0 April 0 MA -, Updated Hydronic Data Aug 0 MA,,, Updated Drain Pan 0 May 0 DS/MA All Updated Dimensional Data for New Vertical ondensate Drain 0 May 0 DS All Updated Nomenclature For New EM Motor 0 Feb 0 DS Added evision uide 0 Feb 0 DS aterfurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact aterfurnace at --- for latest design and SD00HN 0/ Page of

Envision Air Handler Specification Catalog

Envision Air Handler Specification Catalog Air Handler Design Features Factory ptions Accessories Dimensional Data Physical Data Performance Data Engineering uide Specifications Envision Air Handler Specification atalog S00HN 0/ ENVISIN AI HANDLE

More information

SPECIFICATION CATALOG

SPECIFICATION CATALOG SPEIFIATIN ATAL ETHEMAL HEAT PUMPS AFFDABLE ENEWABLE LEAN ASTN SEIES AI HANDLE ASTN SEIES AI HANDLE SPEIFIATIN ATAL Table of ontents Air Handler Nomenclature...........................................................

More information

NAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections

NAH Series. NAH Series Hydronic Air Handler Installation Manual. Air Handler. Installation Information. Water Piping Connections NAH Series Air Handler Installation Information Water Piping onnections Electrical onnections Startup Procedures Preventive Maintenance NAH Series Hydronic Air Handler Installation Manual IM0H 0/ NAH

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List Technical Data Manual Model Nos. and pricing: see Price List Viessmann AirflowPLUS AH2A series Hydronic forced air handler Viessmann AirflowPLUS Product may not be exactly as shown Viessmann AirflowPLUS

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEH3F18B1000A 2/4TEH3F24B1000A 2/4TEH3F30B1000A 2/4TEH3F36B1000A 2/4TEH3F42C1000A 2/4TEH3F48B1000A 2/4TEH3F60B1000A 1½ 5 Ton PUB. NO. 22-1777-10 Features and

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are

More information

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A4018-24C/30-060B 2009 American Standard Heating & Air Conditioning PUB.. 12-1173-04 April 2009 Features and Benefits Duration compressor Efficiency

More information

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGB SERIES 3thru5Ton 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Premier Installation Manual

Premier Installation Manual eothermal/ater Source Heat s / thru on Installation Information Premier Installation Manual ater Piping onnections Desuperheater onnections Electrical Startup Procedures roubleshooting Preventive Maintenance

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD

More information

HORIZONTAL LOW PROFILE FAN COIL IN ROOM HORIZONTAL LOW PROFILE FAN COIL UNITS IN ROOM

HORIZONTAL LOW PROFILE FAN COIL IN ROOM HORIZONTAL LOW PROFILE FAN COIL UNITS IN ROOM HORIZONTAL LOW PROFILE FAN OIL IN ROOM HORIZONTAL LOW PROFILE FAN OIL UNITS IN ROOM HORIZONTAL LOW PROFILE FAN OIL IN ROOM Model series 4H Low Profile, Blow-through Design Sloped drain pan Galvanized or

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended

More information

HydroZone Installation Manual

HydroZone Installation Manual Hydronic omfort Zoning System 4, 8, and 12 Zone apacity Installation Information HydroZone Installation Manual Thermostat Installation Electrical Startup rocedures Wiring Schematics IM1550EW 11/10 HDZNE

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

ARBOR BASE SERIES COMMERCIAL. Arbor Base Series Installation ti Manual. Water Source/Geothermal Heat Pump R-410A Refrigerant Commercial 0.

ARBOR BASE SERIES COMMERCIAL. Arbor Base Series Installation ti Manual. Water Source/Geothermal Heat Pump R-410A Refrigerant Commercial 0. ABO BASE SEIES OMMEIAL Water Source/eothermal Heat Pump -410A efrigerant ommercial 0.75-6 Ton Installation Information Water Piping onnections Hot Water onnections Arbor Base Series Installation ti Manual

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers Black Epoxy Coil GAM5B0A18M11EA GAM5B0A24M21EA GAM5B0B30M21EA GAM5B0B36M31EA GAM5B0C42M31EA GAM5B0C48M41EA GAM5B0C60M51EA Standard Coil GAM5B0A18M11SB GAM5B0A24M21SB

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

Legend Series Installation Manual

Legend Series Installation Manual ESIDENTIAL Geothermal/Water Source Heat Pump -410A efrigerant 2-6 Tons Installation Information Water Piping onnections Hot Water Generator onnections Legend Series Installation Manual Electrical Startup

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

catalog CDV Fan-Coil Units High-Performance, Vertical

catalog CDV Fan-Coil Units High-Performance, Vertical catalog CDV Fan-Coil Units High-Performance, Vertical Catalog: ET115.26-EG8 (415) TABLE OF CONTENTS CDV Fan-Coil Units High-Performance, Vertical Features and Benefits... 3 Construction Features... 4 Standard

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers Modular Multi-position Air Handlers GAM5A0A18M11SA GAM5A0A24M21SA GAM5A0B30M21SA GAM5A0B36M31SA GAM5A0C42M31SA GAM5A0C48M41SA GAM5A0C60M51SA PUB. NO. 22-1845-08 Features and Benefits Unique Cabinet Design

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

5 Series 500R11 Installation Manual

5 Series 500R11 Installation Manual 50011 Indoor Split eothermal Heat Pump -410A efrigerant 2, 2.5, 3, 3.5, 4, 5, 6 Ton Single Speed 2, 3, 4, 5, 6 Ton Dual apacity Installation Information Water Piping onnections Hot Water eneration onnections

More information

SPECIFICATION CATALOG. Commercial 3 to 6 Ton. Water Source/Geothermal Heat Pump

SPECIFICATION CATALOG. Commercial 3 to 6 Ton. Water Source/Geothermal Heat Pump SPEIFIATION ATALOG ommercial 3 to 6 Ton Water Source/Geothermal Heat Pump Table of ontents Model Nomenclature.............................................................. 4 Electrical Availability..............................................................

More information

Air-Cooled Condensers

Air-Cooled Condensers CH-RACCTB APR 2015 Replaces CH-RACCTB April 2011 Air-Cooled Condensers Technical Guide Models WSS Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional Data...5

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

SPECIFICATION CATALOG. Commercial 10 to 15 Ton. Water Source/Geothermal Heat Pump

SPECIFICATION CATALOG. Commercial 10 to 15 Ton. Water Source/Geothermal Heat Pump SPEIFIATION ATALOG ommercial 10 to 15 Ton Water Source/Geothermal Heat Pump Table of ontents Model Nomenclature.............................................................. 4 Electrical Availability..............................................................

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com boschheatingandcooling.com 1 Greensource iseries Water Source Heat Pumps SV Model Made in Florida boschheatingandcooling.com 1 Replacement Water Source Heat Pump About the Bosch Group The Bosch Group has

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XL 15i 4TWX5 1½ 5 Tons PUB. NO. 22-1800-15 Features and Benefits Climatuff compressor Efficiency up to 16.25 SEER and 9.7 HSPF All aluminum Spine Fin coil WeatherGuard II

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL20i 4TTZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1825-08 Features and Benefits Two CLIMATUFF compressors deliver 50% and

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-10 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

INSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES OUTDOOR SPLIT HEATING COOLING HOT WATER.

INSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES OUTDOOR SPLIT HEATING COOLING HOT WATER. INSTALLATION MANUAL HEATIN OOLIN HOT WATE www.geostar-geo.com AFFODABLE ENEWABLE LEAN ASTON SEIES OUTDOO SPLIT ASTON DUAL-APAITY OUTDOO SPLIT SEIES INSTALLATION MANUAL Table of ontents Model Nomenclature..............................................................

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL20i 4TTZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1825-09 Features and Benefits Two CLIMATUFF compressors deliver 50% and

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XL18i 4TTX8024, 036, 048 & 060 2, 3, 4 & 5 Tons PUB. NO. 22-1885-02 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB16 4TTB6 1 1 / 2-5 Tons PUB. NO. 22-1888-01 Features and Benefits Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners QUICK-SESS cabinet, service

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

Commercial Thermostat

Commercial Thermostat ommercial Thermostat Submittal Data *204* 204 ev.: November 18, 2016 limatemaster works continually to improve its products. As a result, the design and specifications of each product at the time of order

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006 Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

AMERICAN STANDARD 14 MODELS 4A7B E

AMERICAN STANDARD 14 MODELS 4A7B E SPLIT SYSTEM COOLING 1 1 / 2 5 ton AMERICAN STANDARD 14 MODELS 4A7B4018-60E PUB. NO. 12-1290-02 June 2009 Features and Benefits DURaTION compressor Efficiency up to 16.0 SEER All aluminum Spine Fin coil

More information

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG: 4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB14 4TTB4 1 1 / 2-5 Tons (018E - 061E) PUB. NO. 22-1833-10 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD

More information

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8 SERVICE UNIT INFORMATION Corp. 9121 L7 CHA16 2 5 TON UNITS Litho U.S.A. CHA16 series units in the 2 5 ton sizes were introduced in the spring of 1990. The single package cooling units may be used in both

More information

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3 DIRECT EXPANSION FAN COIL MODEL FK4C Sizes 001 thru 006 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

INSTALLATION ACCESSORIES

INSTALLATION ACCESSORIES INSTALLATIN CESSIES oom Thermostats The heem Thermostat line includes temperature control solutions for all heem residential and commercial HV equipment Service Valves The service valve kits available

More information

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL

More information

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006 Product Data FK4D Direct Expansion Variable Speed Fan Coil Sizes 001 thru 006 A02332 FK4D Premium Air Handling Technology The FK4D is the latest in air handling technology. It is the perfect unit when

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-1215A Low Profile Unit Cooler Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk - Ins Coolers

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

WALL-MOUNT HEAT PUMPS - (60HZ)