Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Size: px
Start display at page:

Download "Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A"

Transcription

1 Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ 5 Ton R22/R410A 2/4YCX3018A through 2/4YCX3060A Mar. 03, American Standard inc. All Rights Reserved Pub. No

2 It's Hard to Stop a Trane. Single Package Electric Heat Pump System Trane offers a complete family of electric heat pump heating and cooling systems, designed to keep you comfortable all year long, regardless of the weather, while keeping your operating costs as low as possible. A heat pump operates efficiently as both an air conditioner and a heater. In the summer, the heat pump cools your home just like any other air conditioner by pulling the heat from the inside and releasing it outdoors. In the winter, it captures the heat that is always present in the outdoor air and transfers it indoors. Introducing the new TRANE Single Package Electric Heat Pump System. Single Package Electric Heat Pump Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane package heat pump system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control and air distribution ducts, you have a highly efficient, total home comfort system. Single Package Electric Heat Pump Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed adn manufactured for maximum service. Every Climatuff compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability. Single Package Electric Heat Pump Systems provide better performance. Our single package cooling/heating units offer cooling/heating efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition. 2

3 Contents Optional Equipment Listing 4 General Data 5 Heater Data 9 SPEK Data 10 Performance Data Cooling 11 Heating Indoor Fan 19 Typical Wiring 23 Optional Equipment 26 Dimensional Data 31 Mechanical Specifications 35 3

4 Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ] indicates accessories included) Roof Curb Full Perimeter (2/4WCC301836A) 3... BAYCURB050A[ ] Roof Curb Full Perimeter (2/4WCC304260A) 3... BAYCURB051A[ ] Roof Curb Utility Extension Kit (BAYCURB050A)... BAYUTIL101A[ ] Roof Curb Utility Extension Kit (BAYCURB051A)... BAYUTIL102A[ ] 025% Manual Fresh Air Damper (2/4WCC301836A) BAYOSAH001A[ ] 025% Manual Fresh Air Damper (2/4WCC304260A) BAYOSAH002A[ ] Motorized Fresh Air Damper (2/4WCC301836A) BAYDMPR101A[ ] Motorized Fresh Air Damper (2/4WCC304260A) BAYDMPR102A[ ] 16" Round Duct Adapter (2 per box) (2/4WCC301836A) 6... BAYSQRD001A[ ] 18" Round Duct Adapter (2 per box) (2/4WCC304260A) 6... BAYSQRD002A[ ] 0100% Mod Economizer w/baro. Relief (2/4WCC301836A) BAYECON101A[ ] 0100% Mod. Economizer w/baro. Relief (2/4WCC04260A) BAYECON102A[ ] 0100% Horizontal Economizer (2/4WCC301836A) BAYECON200A[ ] 0100% Horizontal Economizer (2/4WCC304260A) BAYECON201A[ ] Economizer Relay Kit (required for Heat Pump applications)... BAYRLAY004A[ ] Enthalpy Control for Economizer (solid state).... BAYENTH001A[ ] Remote Potentiometer (AllBAYECON***A)... BAYSTAT023[ ] 1"2" Filter Frame (2/4WCC301836A) (20 x 20 filter not included) BAYFLTR101A[ ] 1"2" Filter Frame (2/4WCC304260A) (20 x 20,20X18 filter not included) BAYFLTR201A[ ] Evaporator Defrost Control (Low Ambient Cooling) Kit BAYLOAM011A[ ] Head Pressure Control (Low Ambient Cool) (208/240v) Kit BAYLOAM105A[ ] Quick Start Kit (2/4WCC3A1)... BAYKSKT300A[ ] Crankcase Heater Recip (2WCC3024,30,42,48A1, 4WCC3018A1)(230v) BAYCCHT003A[ ] Crankcase Heater Scroll(2WCC3036A1, 4WCC3036,48,60A1/3)(230v) BAYCCHT202A[ ] Crankcase Heater (4WCC3036,48,60A4)(460v) BAYCCHT203A[ ] Adapter Curb 2/4WCC A to BAYCURB030,38... BAYADAP050A[ ] Adapter Curb 2/4WCC A to BAYCURB BAYADAP051A[ ] Adapter Curb 2/4WCC A to BAYCURB030,38... BAYADAP052A[ ] Adapter Curb 2/4WCC A to BAYCURB BAYADAP053A[ ] Adapter Curb 2/4WCC A to BAYCURB BAYADAP054A[ ] 12" Duct Shroud Covers Horizontal *WCC A7.... BAYCOVR112A[ ] 18" Duct Shroud Covers Horizontal *WCC A BAYCOVR118A[ ] Extreme Condition Mounting Kit All BAYCURB & BAYADAP... BAYEXMK001A[ ] Extreme Condition Mounting Kit All BAYUTIL... BAYEXMK002A[ ] Extreme Condition Mounting Kit All Slab Mounts... BAYEXMK003A[ ] Lifting Lug Kit... BAYLlFT002B[ ] SUPPLEMENTARY HEATERS (1 PHASE) 3.76/5.0 KW Heater (208/240V 1PH) (*WCC A1)... BAYHTRV105A[ ] 7.50/10.0 KW Heater (208/240V 1PH) (*WCC A1)... BAYHTRV110A[ ] 11.27/.00 KW Heater (208/240V 1PH) (*WCC A1)... BAYHTRV1A[ ].0/20.0 KW Heater (208/240V 1PH) (*WCC A1)... BAYHTRV120A[ ] SUPPLEMENTARY HEATERS (3 PHASE) 3.76/5.0 KW Heater (208/240V 3PH) (*WCC A3)... BAYHTRV305A[ ] 7.50/10.0 KW Heater (208/240V 3PH) (*WCC A3)... BAYHTRV310A[ ] 11.27/.00 KW Heater (208/240V 3PH) (*WCC A3)... BAYHTRV3A[ ].00/20.0 KW Heater (208/240V 3PH) (*WCC A3)... BAYHTRV320A[ ] 3.76/5.0 KW Heater (460V 3PH) (*WCC A4)... BAYHTRV405A[ ] 7.50/10.0 KW Heater (460V 3PH)*WCC A4)... BAYHTRV410A[ ] 11.27/.00 KW Heater (460V 3PH) (*WCC A4)... BAYHTRV4A[ ].00/20.0 KW Heater (460V 3PH) (*WCC A4)... BAYHTRV420A[ ] Single Power Entry Kit BAYSPEK060A[ ] Single Power Entry Kit BAYSPEK061A[ ] Single Power Entry Kit BAYSPEK062A[ ] Single Power Entry Kit BAYSPEK063A[ ] Single Power Entry Kit BAYSPEK064A[ ] Single Power Entry Kit BAYSPEK065A[ ] NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHTA). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications. 8 See table on page 8 for matching kit with units and heaters. 4

5 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOL) 1BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.)6 Sound Rating No. 2 RATINGS (HEAT) 1 (High Temp.) BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / WattHr.) 6 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. (Amps) Fuse Size Recmd. (Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds 0.0 in. w.g. 4 Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area7 (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4WCC3018A1000A / /1/ SPINE FIN 2 / PLATE FIN 3 / /4 FEMALE NPT PROPELLER 23 DIRECT/ /12 / /1/ /.95 CENTRIFUGAL 11 X 10 DIRECT/2 1/8 / /1/60 1 /1.5 NO Throwaway 2.0 (R410A) 6.4 H X W X D X 44.5 X /348 2WCC3024A1000A / /1/ SPINE FIN 2 / PLATE FIN 3 / /4 FEMALE NPT PROPELLER 23 DIRECT / /5/ /1/ CENTRIFUGAL 11 X 10 DIRECT / 2 1/4 / /1/60 1.4/2.8 NO THROWAWAY 2.7 (R22) 6.5 H X W X D X 44.5 X /357 2WCC3030A1000A / /1/ SPINE FIN 2 / PLATE FIN 3 / /4 FEMALE NPT PROPELLER 23 DIRECT / / 5 / /1/ CENTRIFUGAL 10 X 10 DIRECT / 3 1/2 / /1/60 2 /4.4 NO THROWAWAY 3.3 (R22) 6.2 H X W X D X 44.5 X /358 2WCC3036A1000A / SPINE FIN 2 / PLATE FIN 4 / /4 FEMALE NPT PROPELLER 23 DIRECT / /5 / /1/ / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 3 1/2 / /1/ /5.8 NO THROWAWAY 4.0 (R22) 7 H X W X D X 44.5 X /372 4WCC3036A1000A / SPINE FIN 2 / PLATE FIN 4 / /4 FEMALE NPT PROPELLER 23 DIRECT / /5 / /1/ / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 3 1/2 / /1/ /5.8 NO THROWAWAY 4.0 (R410A) 7.25 H X W X D X 44.5 X /372 1 Certified in accordance with the Unitary AirConditioner Equipment certification program, which is based on ARI Standard 210/ Calculated in accordance with A.R.I. Standard Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 5

6 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOL) 1BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.)6 Sound Rating No. 2 RATINGS (HEAT) 1 (High Temp.) BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / WattHr.) 6 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. (Amps) Fuse Size Recmd. (Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds 0.0 in. w.g. 4 Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area7 (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4WCC3036A3000A /3/ / /3/ /3/ SPINE FIN 2 / PLATE FIN 4 / /4 FEMALE NPT PROPELLER 23 DIRECT / /5 / /1/ CENTRIFUGAL 10 X 10 DIRECT / 3 1/2 / /1/ / 5.8 NO THROWAWAY 4.0 (R410A) 7.25 H X W X D X 44.5 X /372 4WCC3036A4000A 460/3/ / /3/ /3/ SPINE FIN 2 / PLATE FIN 4 / /4 FEMALE NPT PROPELLER 23 DIRECT / /5 / /1/ CENTRIFUGAL 10 X 10 DIRECT / 2 1/2 / /1/ / 3.12 NO THROWAWAY 4.0 (R410A) 7.25 H X W X D X 44.5 X /372 2WCC3042A1000A / /95 SPINE FIN 2/ PLATE FIN 3/ 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT/ / /1/60 1.4/3.1 CENTRIFUGAL 10 x 10 DIRECT/3 1/2/ /1/60 2.5/3.2 NO THROWAWAY 4.7 (R22) 7.65 H X W X D 47.86X47.4X /401 2WCC3048A1000A / /1/ /93.4 SPINE FIN 2/ PLATE FIN 4/ 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT/ / /1/60 1.4/3.1 CENTRIFUGAL 10 x 10 DIRECT/3 3/4/ /1/60 4/8.4 NO THROWAWAY 5.3 (R22) 7.25 H X W X D 47.86X47.4X /425 4WCC3048A1000A / /1/ /109 SPINE FIN 2/ PLATE FIN 4/ 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT/ / /1/60 1.4/3.1 CENTRIFUGAL 10 x 10 DIRECT/3 3/4/ /1/60 4/8.4 NO THROWAWAY 5.3 (R410A) 7.75 H X W X D 47.86X47.4X /425 1 Certified in accordance with the Unitary AirConditioner Equipment certification program, which is based on ARI Standard 210/ Calculated in accordance with A.R.I. Standard Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 6

7 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOL) 1BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.)6 Sound Rating No. 2 RATINGS (HEAT) 1 (High Temp.) BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / WattHr.) 6 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. (Amps) Fuse Size Recmd. (Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds 0.0 in. w.g. 4 Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area7 (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4WCC3048A3000A /3/ / /3/ /1/ SPINE FIN 2 / PLATE FIN 3 / 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / /4 / /1/ / 3.1 CENTRIFUGAL 10 X 10 DIRECT / 3 3/4 / /1/60 4 / 8.4 NO THROWAWAY 5.3 (R410A) 7.75 H X W X D X 47.4 X /425 4WCC3048A4000A 460/3/ / /3/ /3/ SPINE FIN 2 / PLATE FIN 3 / 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / /4 / /1/60.74 / 1.6 CENTRIFUGAL 10 X 10 DIRECT / 2 3/4 / /1/ / 4.36 NO THROWAWAY 5.3 (R410A) 7.75 H X W X D X 47.4 X /425 2WCC3060A1000A / SPINE FIN 2 / PLATE FIN 4 / 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / /4 / /1/ / 3.6 CENTRIFUGAL 11 X 10 DIRECT / 3 1 / / 7.6 NO THROWAWAY 6.7 (R22) 9.7 H X W X D X 47.4 X /495 4WCC3060A1000A / SPINE FIN 2 / PLATE FIN 4 / 5 3/4 FEMALE NPT PROPELLER 23 DIRECT / /4 / /1/ / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 3 1/2 / / 7.6 NO THROWAWAY 4.73 (R410A) H X W X D X 47.4 X /490 4WCC3060A3000A /3/ / /3/ /3/ SPINE FIN 2 / PLATE FIN 4 / 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / /4 / /1/ / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 2 1/2 / / 7.6 NO THROWAWAY 6.7 (R410) H X W X D X 47.4 X /490 1 Certified in accordance with the Unitary AirConditioner Equipment certification program, which is based on ARI Standard 210/ Calculated in accordance with A.R.I. Standard Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 7

8 General Data MODEL RATED Volts/Ph/Hz RATINGS (COOL) 1BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/WattHr.)6 Sound Rating No. 2 RATINGS (HEAT) 1 (High Temp.) BTUH Power Input (KW) (Low Temp.) BTUH Power Input (KW) HSPF (BTU / WattHr.) 6 POWER CONN. V/Ph/Hz Min. Brch. Cir. Ampacity 3 Fuse Size Max. (Amps) Fuse Size Recmd. (Amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds 0.0 in. w.g. 4 Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive / No. Speeds Motor HP / R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps FILTER / FURNISHED? Type Recommended Min. Face Area7 (sq. ft.) REFRIGERANT Charge (lbs.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4WCC3060A4000A 460/3/ / /3/ /3/ SPINE FIN 2 / PLATE FIN 4 / 5 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / /4 / /1/60.74 / 1.6 CENTRIFUGAL 11 X 10 DIRECT / 3 1/2 / / 7.6 NO THROWAWAY 6.7 (R410A) H X W X D X 47.4 X /490 1 Certified in accordance with the Unitary AirConditioner Equipment certification program, which is based on ARI Standard 210/ Calculated in accordance with A.R.I. Standard Calculated in accordance with currently prevailing Nat'l Electrical Code. 4 Standard Air Dry Coil Outdoor. 5 Standard Air Wet Coil Indoor. 6 Rated in accordance with D.O.E. test procedure. 7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C. 8

9 Heater Data 2/4WCC3018A to 2/4WCC3060A Heater Data UNIT MODEL ELECTRIC HEATER MODEL RATED VOLTAGE PHASE AMPS HEATER CAPACITY KW NO. OF STAGES KW / STAGE BTUH 1 2 MCA (2) MAX. FUSE OR HQCR CKT BKR SIZE (4) CANADA ONLY MAX. CKT BKR SIZE (5) ^W/TC*3018A1 ^W/TC*3024A1 ^W/TC*3030A1 ^W/TC*3036A1 ^W/TC*3042A1 ^W/TC*3048A1 ^W/TC*3060A1 ^W/TC*3036A3 ^W/TC*3048A3 ^W/TC*3060A3 ^W/TC*3036A4 ^W/TC*3048A4 ^W/TC*3060A4 BAYHTRV105A 208/ / / / / /26 25/30 25/30 BAYHTRV105A 208/ / / / / /26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV105A 208/ / / / / /26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV1A* 208/ / / / / / /78 70/80 70/80 BAYHTRV105A 208/ / / / / /26 25/30 25/30 BAYHTRV110A 208/ / / / / /52 45/60 45/60 BAYHTRV1A* 208/ / / / / / /78 70/80 70/80 BAYHTRV120A* 208/ /83.00/ / / / /104 90/110 90/110 BAYHTRV305A 208/ / / / / / / / BAYHTRV310A 208/ / / / / /30 30/30 30/30 BAYHTRV3A 208/ / / / / / /45 40/45 40/45 BAYHTRV305A 208/ / / / / / / / BAYHTRV310A 208/ / / / / /30 30/30 30/30 BAYHTRV3A 208/ / / / / / /45 40/45 40/45 BAYHTRV320A 208/ /48.00/ / / / /60 60/60 60/60 BAYHTRV405A BAYHTRV410A BAYHTRV4A BAYHTRV405A BAYHTRV410A BAYHTRV4A BAYHTRV420A NOTES: 1. Any power supply and circuits must be wired and protected in accordance with local electrical codes. (2) The MCA values listed are for electric heater only. 3. Field wire must be rated at least 75 C (4) The HACR circuit breaker is for U.S.A. installations only. (5) For Canada installation reference only. * Heater uses fuses. 9

10 SPEK 2/4WCC3024A to 2/4WCC3060A Single Power Entry Kit Data SINGLE POWER ENTRY KIT BAYSPEK060A BAYSPEK061A SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION HEATER MODEL BAYHTRV105A BAYHTRV305A BAYHTRV310A BAYHTRV405A BAYHTRV410A BAYHTRV4A BAYHTRV420A BAYHTRV105A UNIT MODEL MIN CKT AMP MAX OVER CURRENT DEVICE 2WC*3024A SINGLE POWER ENTRY KIT HEATER MODEL UNIT MODEL MIN CKT AMP MAX OVER CURRENT DEVICE 2WC*3030A WC*3030A WC*3036A WC*3036A WC*3036A WC*3042A WC*3048A WC*3018A WC*3036A WC*3042A BAYHTRV1A 6 2WC*3048A WC*3048A BAYSPEK063A # 6 2WC*3060A WC*3036A WC*3060A WC*3048A WC*3048A WC*3060A WC*3048A BAYHTRV120A 2WC*3060A WC*3036A WC*3060A WC*3048A WC*3036A WC*3036A BAYHTRV3A 4WC*3048A WC*3048A BAYSPEK064A # 4WC*3060A WC*3060A WC*3036A WC*3048A BAYSPEK065A # 4WC*3060A WC*3036A WC*3048A WC*3060A WC*3048A WC*3060A WC*3048A WC*3060A WC*3060A WC*3048A BAYHTRV320A 2 4WC*3060A BAYHTRV310A 4WC*3060A BAYSPEK062A # BAYHTRV110A 2WC*3024A WC*3030A WC*3036A WC*3036A WC*3042A WC*3048A WC*3048A WC*3060A WC*3060A # Single Circuit Power fuses are supplied if required for unit and/or heater. From Dwg. 21C P01& 2 10

11 Performance Data Cooling 2WCC3024A AT 800 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 725 CFM COMPRESSOR POWER = 1691 WATTS I.D. FAN POWER = 190 WATTS O.D. FAN POWER = 210 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 2WCC3030A AT 1000 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1025 CFM COMPRESSOR POWER = 1991 WATTS I.D. FAN POWER = 334 WATTS O.D. FAN POWER = 220 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 2WCC3036A AT 1200 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 2520 WATTS I.D. FAN POWER = 425 WATTS O.D. FAN POWER = 237 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 11

12 Performance Data Cooling 2WCC3042A AT 1400 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1401 CFM COMPRESSOR POWER = 2856 WATTS I.D. FAN POWER = 5 WATTS O.D. FAN POWER = 265 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 2WCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1700 CFM COMPRESSOR POWER = 3321 WATTS I.D. FAN POWER = 599 WATTS O.D. FAN POWER = 307 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 2WCC3060A AT 2000 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1850 CFM COMPRESSOR POWER = 4358 WATTS I.D. FAN POWER = 559 WATTS O.D. FAN POWER = 356 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 12

13 Performance Data Cooling 4WCC3018A AT 600 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 675 CFM COMPRESSOR POWER = 1313 WATTS I.D. FAN POWER = 219 WATTS O.D. FAN POWER = 104 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4WCC3036A AT 1200 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 2507 WATTS I.D. FAN POWER = 446 WATTS O.D. FAN POWER = 229 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 4WCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1601 CFM COMPRESSOR POWER = 3418 WATTS I.D. FAN POWER = 595 WATTS O.D. FAN POWER = 313 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 13

14 Performance Data Cooling 4WCC3060A AT 2000 CFM (CAPACITIES ARE NET IN BTUH/1000INDOOR FAN HEAT DEDUCTED) O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP KW CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = BTUH AIRFLOW = 1850 CFM COMPRESSOR POWER = 4495 WATTS I.D. FAN POWER = 550 WATTS O.D. FAN POWER = 301 WATTS S.E.E.R. = BTUH/WATT E.E.R = BTUH/WATT ALL TEMPERATURES IN DEGREES F. 14

15 Performance Data Heating 2WCC3024A AT 800 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 800 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 800 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = 100 BTUH COMPR. POWER (HIGH TEMP.) = 1813 WATTS COMPR. POWER (LOW TEMP.) = 18 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.62 COEFF. OF PERF. (LOW TEMP.) = 2.22 OUTDOOR FAN POWER = 210 WATTS INDOOR FAN POWER = 190 WATTS 2WCC3030A AT 1000 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1000 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1000 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = 700 BTUH COMPR. POWER (HIGH TEMP.) = 2360 WATTS COMPR. POWER (LOW TEMP.) = 1957 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.55 COEFF. OF PERF. (LOW TEMP.) = 2.35 OUTDOOR FAN POWER = 220 WATTS INDOOR FAN POWER = 334 WATTS 2WCC3036A AT 1200 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1200 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1200 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 3070 WATTS COMPR. POWER (LOW TEMP.) = 2798 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.55 COEFF. OF PERF. (LOW TEMP.) = 2.45 OUTDOOR FAN POWER = 237 WATTS INDOOR FAN POWER = 425 WATTS

16 Performance Data Heating 2WCC3042A AT 1400 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1400 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1400 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 3211 WATTS COMPR. POWER (LOW TEMP.) = 2967 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.65 COEFF. OF PERF. (LOW TEMP.) = 2.35 OUTDOOR FAN POWER = 265 WATTS INDOOR FAN POWER = 5 WATTS 2WCC3048A AT 1600 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1600 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1600 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 3539 WATTS COMPR. POWER (LOW TEMP.) = 2930 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.85 COEFF. OF PERF. (LOW TEMP.) = 2.40 OUTDOOR FAN POWER = 307 WATTS INDOOR FAN POWER = 599 WATTS 2WCC3060A AT 2000 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 2000 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 2000 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 4593 WATTS COMPR. POWER (LOW TEMP.) = 41 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.70 COEFF. OF PERF. (LOW TEMP.) = 2.40 OUTDOOR FAN POWER = 356 WATTS INDOOR FAN POWER = 559 WATTS 16

17 Performance Data Heating 4WCC3018A AT 600 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 600 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 600 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = 6000 BTUH COMPR. POWER (HIGH TEMP.) = 1489 WATTS COMPR. POWER (LOW TEMP.) = 858 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.70 COEFF. OF PERF. (LOW TEMP.) = 2.05 OUTDOOR FAN POWER = 104 WATTS INDOOR FAN POWER = 219 WATTS 4WCC3036A AT 1200 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1200 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1200 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 39 WATTS COMPR. POWER (LOW TEMP.) = 2990 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.45 COEFF. OF PERF. (LOW TEMP.) = 1.95 OUTDOOR FAN POWER = 229 WATTS INDOOR FAN POWER = 446 WATTS 4WCC3048A AT 1600 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 1600 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 1600 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 3935 WATTS COMPR. POWER (LOW TEMP.) = 3672 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.50 COEFF. OF PERF. (LOW TEMP.) = 2.25 OUTDOOR FAN POWER = 313 WATTS INDOOR FAN POWER = 595 WATTS 17

18 Performance Data Heating 4WCC3060A AT 2000 CFM O.D. HEATING CAPACITY (BTUH/1000) AT TOTAL POWER IN KILOWATTS AT TEMP. INDICATED INDOOR DRY BULB TEMP. INDICATED INDOOR DRY BULB TEMP. F CORRECTION FACTORS FOR OTHER AIRFLOWS (VALUE AT 2000 CFM TIMES CORR. FACTOR = VALUE AT NEW AIRFLOW) AIRFLOW HEATING CAP. X X COMPR. KW X X VALUES AT ARI RATING CONDITIONS OF: 70&47/43 (HIGH TEMP. POINT) 70&17/ (LOW TEMP. POINT) AIRFLOW = 2000 CFM HEATING CAP. (HIGH TEMP.) = BTUH HEATING CAP. (LOW TEMP.) = BTUH COMPR. POWER (HIGH TEMP.) = 5204 WATTS COMPR. POWER (LOW TEMP.) = 3143 WATTS HSPF (MIN DHR ZONE 4) = 7.70 COEFF. OF PERF. (HIGH TEMP.) = 3.35 COEFF. OF PERF. (LOW TEMP.) = 2.20 OUTDOOR FAN POWER = 301 WATTS INDOOR FAN POWER = 550 WATTS 18

19 Indoor Fan Performance 2/4WCC3018A1 Horizontal Airflow 2/4WC*3018A1 HOR Down Airflow 2/4WC*3018A1 DOWN Indoor Blower Performance EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW HIGH EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW HIGH WATTS CFM WATTS CFM WATTS CFM WATTS CFM Indoor Fan Performance 2/4WCC024A1 Horizontal Airflow 2/4WC*3024A1HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM HIGH WATTS CFM Down Airflow 2/4WC*3024A1DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM HIGH WATTS CFM

20 Indoor Fan Performance 2/4WCC3030A1 Horizontal Airflow Indoor Blower Performance 2/4WC*3030A1HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MEDIUM WATTS CFM HIGH WATTS CFM Down Airflow 2/4WC*3030A1DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED WATTS LOW CFM WATTS MEDIUM CFM WATTS HIGH CFM Indoor Fan Performance 2/4WCC3036A Horizontal Airflow 2/4WC*3036AHOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MEDIUM WATTS CFM HIGH WATTS CFM Down Airflow 2 /4WC*3036ADOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MEDIUM WATTS CFM HIGH WATTS CFM

21 Indoor Fan Performance 2/4WCC3042A1 Horizontal Airflow Indoor Blower Performance 2WC*3042A1HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED WATTS LOW CFM WATTS MEDIUM CFM WATTS HIGH CFM Down Airflow 2 /4WC*3042A1DWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED WATTS LOW CFM WATTS MEDIUM CFM WATTS HIGH CFM Indoor Fan Performance 2/4WCC3048A Horizontal Airflow 2 /4WC*3048A1 HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MED WATTS CFM HIGH WATTS CFM Down Airflow 2 /4WC*3048A1 DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MED WATTS CFM HIGH WATTS CFM

22 Indoor Fan Performance 2/4WCC3060A Horizontal Airflow Indoor Blower Performance 2/4WC*3060A1HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MEDIUM WATTS CFM HIGH WATTS CFM Down Airflow 2/4WC*3060A1DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED LOW WATTS CFM MEDIUM WATTS CFM HIGH WATTS CFM

23 Field Wiring Diagram GROUND WIRE 1 PH POWER 1 PH POWER 3 PH 3 PH POWER POWER UNIT HEATER NOTE 1,8 UNIT CONTROL BOX TYPICAL THERMOSTAT UNIT HEATER AREA FACTORY PROVIDED FIELD CONNECTED WIRES UNIT CONTROL BOX UNIT LOW VOLTAGE AREA B G Y W1 W2 O T R POLARIZED PLUG COMMON FAN COMPRSSOR 1ST STAGE ELECTRIC HEAT 2ND STAGE ELECTRIC HEAT SWITCHOVER VALVE UNIT HEATER AREA DEFROST CONTROL 'T' SIGNAL 24 VOLTS (BL) (YL) ELECTRIC HEATER CONTROL BOX FIG. 1 SINGLE POWER ENTRY ACCESSORY CONNECTIONS FIG. 2 ECONOMIZER ACCESSORY CONNECTIONS TO COMPR. CONTACTOR ELECTRIC HEATER CONTROL BOX TO ECONOMIZER FACTORY PROVIDED FIELD INSTALLED WIRES NOTE 9 (NOT APPLICABLE TO THE WCMF MODELS) (BL) NOTES: 1. FUSED DISCONNECT SIZE, POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH CODES. 2. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT AND HEATER NAMEPLATE. 3. LOW VOLTAGE WIRING TO BE 18 AWG MINIMUM CONDUCTOR. 4. SEE HEATER NAMEPLATE FOR CURRENT RATING OF HEATER USED. 5. SEE UNIT AND HEATER DIAGRAM FOR ELECTRICAL CONNECTION DETAILS. 6. IF ELECTRIC HEATER ACCESSORY IS NOT INSTALLED OMIT THE ELECTRIC HEATER, ASSOCIATED POWER WIRES AND THE W AND X2 THERMOSTAT WIRES. 7. FIG. 3 DEMONSTRATES CONNECTION OF THE OUTDOOR THERMOSTAT ACCESSORY ONLY. FOR FURTHER UNIT CONNECTION DETAILS REFER TO THE OTHER FIGURES. 8. THE 41A(BR) WIRE IS FIRST STAGE ELECTRIC HEAT. IF THE ELECTRIC HEATER ACCESSORY HAS TWO HEATING STAGES THE 41C(BR) WIRE IS SECOND STAGE ELECTRIC HEAT. 9. WHEN THE BAYECON054A OR 055A ECONOMIZER IS INSTALLED THE BAYRLAY003 RELAY ACCESSORY KIT IS REQUIRED TO INTERFACE THE ECONOMIZER TO THE HEAT PUMP FOR PROPER SYSTEM OPERATION. WHEN THE BAYECON054B OR 055B OR 073A ECONOMIZER IS INSTALLED, THE BAYRLAY004A RELAY ACCESSORY KIT IS REQUIRED TO INTERFACE THE ECONOMIZER TO THE HEAT PUMP FOR PROPER SYSTEM OPERATION. 10. THE BAYSTAT033A OUTDOOR THERMOSTAT ACCESSORY KIT CONTAINS A THERMOSTAT AND A RELAY. THE RELAY IS NOT REQUIRED TO BE USED IN THIS APPLICATION. B 1 PH POWER 3 PH POWER SINGLE POWR ENTRY UNIT LOW VOLTAGE AREA GROUND WIRE SPE ACCESSORY KIT UNIT FUSES HEATER FUSES SEE SPEK INSTALLER'S GUIDE FOR ALL OTHER EXAMPLES UNIT LOW VOLTAGE AREA (GR) (PR) TYPICAL 2STAGE THERMOSTAT (OR) (OR) (GR) G (YL) Y (WH) W1 (WH) W2 (OR) O (BR) T (RD) R FIG. 3 OUTDOOR THERMOSTAT ACCESSORY CONNECTIONS UNIT LOW VOLTAGE AREA HEATER SECOND STAGE AMBIENT TEMPERATURE LOCKOUT NOTE 7,8 (WH) W1 (WH) W2 UNIT LOW VOLTAGE AREA HEATER AMBIENT TEMPERATURE LOCKOUT NOTE 7,8 (WH) W1 (WH) W2 OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A NOTE 10 OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A NOTE 10 TYPICAL THERMOSTAT TYPICAL THERMOSTAT 23

24 Typical Wiring 24

25 Typical Wiring From Dwg. 21D P02 WARNING: Do NOT connect 24 VAC to T1 terminal. ODSB thermister WILL BE BLOWN. 25

26 Optional Equipment BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR *****018036A /2 SUPPLY /2 RETURN 14 13/ /2 1 1/ /2 D A WOOD NAILER SUPPLY AIR C RETURN AIR B CHANNEL END CHANNEL SIDE HOLE IN ROOF SERVICE CLEARANCE DIMENSIONS A B C D 42" 36" 12"* 42" 22 *42 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY BAYCURB050A 26

27 Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042060A /2 SUPPLY / RETURN 14 13/16 1 1/2 1 1/ /2 D A WOOD NAILER SUPPLY AIR C RETURN AIR B CHANNEL SIDE CHANNEL END HOLE IN ROOF SERVICE CLEARANCE DIMENSIONS A B C D 42" 36" 12"* 42" *42 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY BAYCURB051A 22 27

28 BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Optional Equipment A Economizer rain hood Mist eliminator Outside air dampers Return air dampers Required filter kit, order separately Economizer BAYECON101A BAYECON102A Unit ApplicationM odels 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A A " " Relief damper Roofcurb Return Duct BAYCON200,201A Horizontal Economizer and Rain Hood Economizer A B C Gaskets (2) Duct Rain Hood Economizer Unit Application Models A B C BAYECON200AA BAYECON201AA 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A 22.00" 20.00" 16.87" 24.00" 22.65" 19.00" 28

29 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) A FULLY OPEN D C 2/3 1/3 B FULLY CLOSED Manual Fresh Air Model BAYOSAH001 BAYOSAH002 Unit Application Models 2/4YC,WC A 4TC* A 2/4YC,WC A 4TC* A A B C D 22 7/16" 20 11/16" 12 " 9 3/16" 25 3/16" 20 11/16" 12 " 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C B E D BAYDMPR101A BAYDMPR102A Unit Application Models 2/4YC,WC A 4TC A 2/4YC,WC A 4TC A A B C D E 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4" 18 3/16" 1/8" 10 1/4" 11 1/2" 12 1/4" 29

30 Optional Equipment BAYFLTR101, 201A, 1" 2" Filter Rack (Mounts in Filter/Coil Section) Filter 30

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006 Product Data 22-1782-01 4TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A Mar. 03, 2006 2006 American Standard inc. All Rights Reserved Pub. No. 22-1782-01 It's Hard

More information

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08 Product Data 22-1782-05 4TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 2008 Trane Pub. No. 22-1782-05 07/08 Single Packaged Cooling System Trane offers a complete

More information

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No. Product Data 22-1789-06 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A 2007 Trane Pub. No. 22-1789-06 Single Packaged Electric Heat Pump System Trane offers a

More information

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A Product Data 22-1807-09 4WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 06/14 2014 Trane Pub. No. 22-1807-09 It's Hard to Stop a Trane. Single Packaged Electric

More information

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014 Product Data Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton 4WCC4024A1000A 4WCC4030A1000A 4WCC4036A1000A 4WCC4042A1000A 4WCC4048A1000A 4WCC4060A1000A Note: Graphics in this document are for representation

More information

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12 Product Data 22-1780-11 4WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12 2012 Trane Pub. No. 22-1780-11 It's Hard to Stop a Trane. Single Packaged Electric

More information

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A Product Data 4DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, 75-120 KBTU R-410A 2008 Trane Pub. No. Single Packaged Convertible Dual Fuel System Trane offers a complete

More information

SEER 1½

SEER 1½ Product Data 22-1782-13 4TCC3018 through 4TCC3060 Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 2013 Trane Pub. No. 22-1782-13 07/13 It's Hard to Stop a Trane. Single Packaged Cooling System

More information

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No. Product Data 22179614 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2 5 Ton R410A 2013 Trane Pub. No. 22179614 It's Hard to Stop a Trane. Single Packaged Cooling System Trane offers

More information

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A Product Data 22-1799-20-EN 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, 60-120 MBTU R-410A 2014Trane Pub. No. 22-1799-20-EN It's Hard to Stop a Trane. Packaged Convertible

More information

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A Product Data 4DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, 75-120 MBTU R-410A 2012 Trane Pub. No. It's Hard to Stop a Trane. Single Packaged Convertible Dual Fuel

More information

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ / YCC30A-SPEC-1D TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING SPECIFICATIONS 2/4YCC30A1096/120A PRODUCT SPECIFICATIONS MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power Input

More information

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ / YCC3036A-SPEC-1E TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3036A1064/75/96A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

4YCC3048A3096A /3/ /

4YCC3048A3096A /3/ / YCC3048A-SPEC-3A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS SPECIFICATIONS 4YCC3048A3075/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A Product Data 22-1808-11 4YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, 75-120 MBTU R-410A 2011 Trane Pub. No. 22-1808-11 It's Hard to Stop a Trane. Single Packaged

More information

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ / YCC3048-SPEC-1B TAG: SPECIFICATIONS SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2/4YCC3048A107/96/120A MODEL RATED Volts/PH/Hz Performance Cooling BTUH Indoor Airflow (CFM) Power

More information

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG: Submittal Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified

More information

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG: 4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

4YCC3036A1075B /1/ / YCC3036A1064B /1/ / 4YCC3036A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG: Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A1060A SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing

More information

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG: Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR

More information

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG: Submittal Split System Cooling 5.0 Ton 4A7A3060D1000P SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION Service Facts Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION 4TTB6-SF-3 UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED.

More information

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8 Service Facts Split System Cooling 4TTR3060D1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6024A1000B 4TTR6024A1000B 208/230/1/60 18 20 CLIMATUFF - SCROLL 1-2 208/230/1/60 13.0-52 PROPELLER 27.6-1 DIRECT - 1 3200 1-1/8 835 208/230/1/60 0.74 SPINE FIN 1-24

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG: Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING Service Facts Split System Cooling 4TTR6048A1000A 4TTR6048A1000A 208/230/1/60 28 45 CLIMATUFF - SCROLL 1-2 208/230/1/60 21.2-104 PROPELLER 27.6-1 DIRECT - 1 4260 1-1/5 825 208/230/1/60 1.0 SPINE FIN 1-24

More information

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT Service Facts Split System Cooling 4TTR6036B1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES Service Facts Split System Cooling 4TTB18E1000A, 4TTB24E1000A 4TTBD1000B, 4TTB36D1000B 4TTB3-SF-1B CAUTION UNIT CONTAINS R-410A REFRIGERANT R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel 65/8 TAG: M4PH4024A1000A SUBMITTAL 2.0 Ton Heat Pump Package Units M4PH4024A1000A Front 2413/16 89/16 23/8 181/2 219/16 52 311/16 1211/16 65/8 Hi./Lo. pressure service port 1/4 SAE 65/8 45/16 19/16 57/8

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data 2TTB0030-060A 2½ 5 Tons 22-1739-04 General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems represent a product that is

More information

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8 Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/ Service Facts Split System Heat Pump 4TWB4024E1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG: Submittal 5 Ton Convertible Air Handler TEM3A0C60S51SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES Service Facts Split System Heat Pump 4A6H5049E1000B IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit.

More information

Split System Cooling Product Data XB 1000

Split System Cooling Product Data XB 1000 Split System Cooling Product TTB-D-7 XB 1000 TTB012-060C PUB. NO. 22-1689-02-797 (EN) General Features Split System Cooling Units... Designed With Your Needs In Mind. TTB Split systems represent a new

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT Service Facts Split System Heat Pump 4A6H5042G1000A CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this

More information

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG: Submittal 1 1/2 Ton Convertible Air Handler SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG: Submittal 2 Ton Convertible Air Handler TEM3A0B24S21SA SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A Service Facts Split System Cooling 3.0 Ton 4A7A6036J1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING Only qualified personnel should

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4 Product catalog Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4 Features and Benefits Outdoor unit 4TTB Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Hyperion TM Split Systems

Hyperion TM Split Systems Hyperion TM Split Systems Split Systems Air Conditioning (Ducted Type) 3.0-5.0 Tons - R410a - 50Hz Indoor Units GAF2A0A36S3ASA GAT2A0C48S4ASA GAT2A0C60S5ASA GAM2A0C48S4ASB GAM2A0C60S5ASB Outdoor Units

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data Three Phase 2TTA3048-060A3 4 5 Tons PUB. NO. 22-1770-03 Features and Benefits All aluminum Spine Fin coil Durable base, fast complete drain, weather proof

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-13 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product XR15 4TWR5 1 1 /2-5 Tons PUB. NO. 22-1832-10 Features and Benefits CLIMATUFF compressor Efficiency up to 17.0 SEER and 9.0 HSPF All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

Product Data. Split System Cooling A. November 2013

Product Data. Split System Cooling A. November 2013 Product Data Split System Cooling 4TTR3018G1000A 4TTR3024G1000A 4TTR3030G1000A 4TTR3036E1000A 4TTR3042D1000A 4TTR3048D1000A 4TTR3060D1000A November 2013 22-1842-8A Product Specifications Model No. (a)

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump D-EN. February 2016 Product Data Split System Heat Pump 4A6H6018H1000A 4A6H6024H1000A 4A6H6030H1000A 4A6H6036H1000A 4A6H6042H1000A 4A6H6048H1000A 4A6H6060H1000A Note: Graphics in this document are for representation only.

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XB14 4TTB4 1 1 /2-5 Tons (018E - 061E) PUB. NO. 22-1833-08 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Unit Features & Benefits RQPM/RQRM Series

Unit Features & Benefits RQPM/RQRM Series 2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable

More information

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump A-EN. March 2016 Product Data Split System Heat Pump 4A6H4018G1000A 4A6H4024G1000A 4A6H4030G1000A 4A6H4036D1000A 4A6H4042G1000A 4A6H4048G1000A 4A6H4060G1000A Note: Graphics in this document are for representation only.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COMBINATION HEATING AND COOLING ROOFTOP UNITS RKKB SERIES 7.5, 8.5, 10, 12.5 & 15 TON [26.4, 29.9, 35.2 44 & 52.8 kw] RKMB SERIES 7.5, 8.5, 10 & 12.5 TON [26.4, 29.9, 35.2

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017 Product Catalog Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz June 2017 RT-PRC079B-EN Introduction Packaged Rooftop Air Conditioners Copyright Through the years, Trane

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Product Data Split System Cooling

Product Data Split System Cooling Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N 4TTR3042E1000N 4TTR3043A1000N 4TTR3048E1000N 4TTR3049A1000N 4TTR3060D1000N August 2017 22-1842-8H-EN Outline

More information

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES 50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XB14 4TTB4 1 1 / 2-5 Tons (018E - 061E) PUB. NO. 22-1833-10 Features and Benefits CLIMATUFF compressor Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD

More information

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 5 Ton Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These

More information

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H3018-060A 2008 American Standard Heating & Air Conditioning PUB. NO. 12-1216-02 June 2008 Features and Benefits Duration compressor Efficiency up

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Illusion Split System

Illusion Split System Illusion Split System 50 Hz/R410A Range:1-5 Tons Indoor Units MCDA18DB MCDA24DB MCDA30DB MCDA36DB MCDB42DB MCDB48DB MCDB60DB Outdoor Units 4TTB3018AA 4TTB3024AA 4TTB3030AA 4TTB3036AA 4TTA3030AD 4TTA3036AD

More information

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling H-EN. January 2017 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000B 4TTR4025L1000B 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A Product Data Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A Note: Graphics in this document are for representation only.

More information