1 Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail. Effects of moisture on equipment Malfunctioning of valves and actuators caused by dripping grease Decomposition of auto drain caused by rusting inside pipes Generation of water droplets Standard inlet air temperature type IDF le/f/d Series ir flow capacity: Increased by up to 40% (SM comparison) Power consumption: Reduced by up to 40% (SM comparison) Improved corrosion resistance with the stainless steel heat exchanger *1 Rated inlet condition pplicable air compressor [kw] IDF1E 0.75 IDF2E 1.5 Rc3/8 IDF3E 2.2 IDF4E 3.7 Rc1/2 IDF6E IDF8E 0.7 MPa 7.5 Rc3/4 IDF11E 11 IDF15E1 15 Rc1 IDF22E 22 R1 IDFlE IDF37E 37 R1 1/2 IDF55E IDF75E 0.7 MPa 75 R2 The air dryers (E or UL compliant) conforming to the international standards are separately available. *1 IDF4E to 75E/IDU3E to 75E Large size series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type mbient temperature 45 /Inlet air temperature 60 (IDF100F to 150F) Energy saving design Exhaust heat amount is reduced 25% to suppress the ambient temperature rise (air-cooled type) and reduce the facility water amount (water-cooled type) (IDF100F to 150F). Rated inlet condition pplicable air compressor [kw] 100 R2 IDF100F IDF125F (2 1/2B) Flange 40 IDF150F MPa 80 (3B) Flange IDF190D 190 IDF240D (4B) Flange 35 IDF370D 0.7 MPa (6B) Flange High inlet air temperature type IDU le Series Rated inlet pplicable air condition compressor [kw] IDU3E 2.2 Rc3/8 IDU4E 3.7 Rc1/2 IDU6E 5.5 IDU8E 7.5 Rc3/4 IDU11E IDU15E1 0.7 MPa 15 Rc1 IDU22E 22 R1 IDU37E 37 R1 1/2 IDU55E 55 IDU75E 75 R2 * IDF4E to 75E/IDU3E to 75E IDUlE ir-cooled type Water-cooled type IDFlF IDFlD IDF/IDU Series T.ES30-8J

2 Refrigerated ir Dryer IDF100F/125F/150F Series Tolerant of high temperature environment (ambient temperature 45 ), Energy saving design! ir-cooled type can be used at ambient temperature 45. Second re-heater helps the heat radiation of the condenser allow use at ambient temperature 45. New air dryer urrent air dryer ompressed Second re-heater cools air outlet the refrigerant and reduces the load to the condenser. It is warmed by the second re-heater, preventing condensation of the piping on the outlet side. It cannot radiate heat if the ambient temperature is excessive. ompressed air outlet ondenser Second re-heater ondenser ompressor for refrigeration ompressor for refrigeration Refrigerant Refrigerant ompressed air after removing humidity ompressed air after removing humidity Energy saving design: Reduces exhaust heat from air dryer by up to 25%. Suppresses ambient temperature increase (air-cooled type)/ Reduces amount of facility water (water-cooled type)! Second re-heater reduces the load to the condenser, and reduces exhaust heat from air dryer by up to 25%. (comparison with other SM products) Reduced exhaust heat achieves downsizing and energy saving operation of the air conditioner! Exhaust heat Exhaust heat Exhaust heat from air dryer ir conditioner ir conditioner Exhaust heat Exhaust heat 1 Indoor Outdoor Indoor 2 Reduced by 25% 9 kw 12 kw F type Exhaust heat from new air dryer 1 Exhaust heat from current air dryer 2 ondition: The IDF100F is operated with the rated condition of 60 Hz. 1 New air dryer (With second re-heater) urrent air dryer (Without second re-heater)

3 IDF100F/125F/150F Series Maintenance Dustproof filter provided as a standard accessory Only access from front side is required to check electrical equipment and dustproof filter. Dustproof filter Electrical equipment Selection of layout [ir-cooled type] Exhausting can be selected from four s!! uto drain tube can be connected in two s, left or right. [Water-cooled type] Facility water piping port can be selected from two s!! Left Top Rear Facility water outlet Facility water outlet Left Right Right Facility water inlet Facility water inlet Temperature control equipment void exhausting air onto adjacent equipment. HRS100/150 series Space saving Either the left or right can be installed flat against a wall! * 1 Installation space can be reduced by up to 1.5 m 2!! *1 For air-cooled type, leave a space of at least 600 mm between the heat exhausting surface and the wall. For water-cooled type, leave a space at least 600 mm between the facility water piping side and the wall. Leave at least 600 mm on the sides indicated with. Wall Installation space of the IDF100F (Example: Installed flat against the wall on the left) Installation space of the current type 2

4 omplies with F restrictions Refrigerated ir Dryers IDF/IDU Series ontents Standard Inlet ir Temperature Type IDFmE/F/D Series Rated inlet air temperature: 35, 40 IDF1E Rated inlet condition ir flow capacity [m 3 /min(nr)] 50 Hz 60 Hz pplicable air compressor [kw] Refrigerant Page IDF2E Rc3/8 IDF3E IDF4E Rc1/2 R134a (HF) IDF6E MPa IDF8E Rc3/4 p. 7 to 10 IDF11E IDF15E Rc1 IDF22E R1 IDF37E R1 1/2 IDF55E p. 11 to 13 IDF75E R2 Large size series IDF100F R407 IDF125F (2 1/2B) Flange 0.7 MPa (HF) IDF150F IDF190D (3B) Flange IDF240D (4B) Flange IDF370D MPa (6B) Flange p. 14 to 21 High Inlet ir Temperature Type IDUmE Series Rated inlet air temperature: 55 IDU3E Rated inlet condition ir flow capacity [m 3 /min(nr)] 50 Hz 60 Hz pplicable air compressor [kw] Refrigerant Page Rc3/8 IDU4E Rc1/2 IDU6E IDU8E R134a (HF) Rc3/4 p. 22 to 24 IDU11E IDU15E1 0.7 MPa Rc1 IDU22E R1 IDU37E IDU55E R407 (HF) R1 1/2 R2 IDU75E p. 25 to 27 3 Refer to the Web atalog for air dryer models conforming to international standards (E and UL).

5 Description pplicable model (Suffix: Option symbol) ool compressed air output IDF1E to 75E DFmE-m- IDF1E to 75E IDFmE-m- nti-corrosive treatment for copper tube IDF100F to 150F IDFmF-m- IDF190D to 370D IDFmD-m(-m)- IDU3E to 75E IDUmE-m- With hinese labels and IDF1E to 75E IDFmE-m-G a hinese operation manual IDU3E to 75E IDUmE-m-G p. 28, 29 IDF6E to 37E IDFmE-m-K Moderate pressure specification (up to 1.6 MPa) IDU3E to 15E1 IDUmE-m-K IDF100F to 150F IDFmF-m-K IDF4E to 75E IDFmE-m-L With a heavy-duty auto drain *1 (applicable to moderate pressure) IDF370D IDF370D-m-L IDU3E to 75E IDUmE-m-L With a motor type auto drain *2 IDF190D, 240D IDFmD-m(-m)-M p. 30 IDF4E to 75E IDFmE-m-M IDU3E to 75E IDUmE-m-M With a metal name plate IDF100F to 150F IDFmF-m-P p. 30 IDF4E to 75E IDFmE-m-R With an earth leakage breaker IDF100F to 150F IDFmF-m-R IDF190D to 370D IDFmD-3-R p. 31 IDU3E to 75E IDUmE-m-R Power supply terminal block connection IDF1E to 15E1-10 IDFmE-10-S IDU3E to 15E1-10 IDUmE-10-S With a terminal block for power supply, IDF4E to 75E IDFmE-m-T operating, and error signals *3 IDU3E to 75E IDUmE-m-T p. 32 With a timer controlled solenoid valve type auto drain IDU3E to 75E IDUmE-m-V (applicable to moderate pressure) IDF100F to 150F IDFmF-m-V IDF100F to 150F IDFmF-m-W Water-cooled type *2 IDF190D, 240D IDFmD-3-W p. 33 *1 The IDF100F to 150F, 190D, 240D standard types are equipped with a heavy-duty auto drain and a terminal block for remote operation, stop, operating, and error signal. *2 The IDF370D standard type is the water-cooled type with a motor type auto drain. *3 When switching from the previous air dryer and remote operation are required, select the Made to Order (IDF/UmE-m-X256) product. The IDF100F to 150F and 190D to 370D standard types are equipped with a terminal block for remote operation, stop, operating, and error signals. Optional ccessories Page Selection IDF F IDF D Description Separately installed power transformer Dedicated base for separately installed power transformer Dust-protecting filter set Bypass piping set Foundation bolt set Piping adapter Mounting base adapter onversion piping set onversion bypass piping set Page p. 34 to 43 4 Optional ccessories Specific Product Precautions

6 IDF/IDU Series Selection The corrected air flow capacity, which considers the user s operating conditions, is required for selecting air dryer. Select using the following procedures Read the correction factors. alculate the corrected air flow capacity. Obtain the corrected air flow capacity from the following formula. orrected air flow capacity = ir flow rate (orrection factor x B x x D) 5 Select the model. Select the model with air flow capacity which exceeds the corrected air flow capacity from the specification table. (For air flow capacity, refer to the data E on page 6.) Select the IDF or IDU. Obtain the correction factors to D suitable for your operating condition from the table on the next page. heck the coefficient. IDF Selection Example orrected air flow capacity = 0.3 m 3 /min (0.82 x 0.96 x 1 x 0.88) = 0.43 m 3 /min ccording to the corrected air flow capacity of 0.43 m 3 /min, the IDF4E will be selected which air flow capacity is 0.52 m 3 /min at 50 Hz. Refer to pages 28 to 33. Refer to pages 28 to 32. Finalize the model number. Select the optional accessories. Select the IDF or IDU from inlet air temperature used. Inlet air temperature 5 to 50 IDF (For IDF100F to 150F, up to 60 is allowed.) Inlet air temperature 50 to 80 IDU orrection factor = 0.82 x 0.96 x 1 x 0.88 = 0.69 Max. coefficient value is 1.5. orrection factor is 1.5 when the calculation result is 1.5 or greater. Refer to pages 7, 11, 14, 19. Refer to pages 34 to 43. IDU Selection Example ondition Data symbol orrection factor *1 ondition Data symbol orrection factor *1 Inlet air temperature Inlet air temperature mbient temperature 35 B 0.96 mbient temperature 35 B 0.93 Outlet air pressure dew point 10 1 Outlet air pressure dew point 10 1 Inlet air pressure 0.5 MPa D 0.88 Inlet air pressure 0.5 MPa D 0.88 ir flow rate 0.3 m 3 /min ir flow rate 0.4 m 3 /min Power supply frequency 50 Hz Power supply frequency 60 Hz *1 Values obtained from orrection Factors on page 6. *1 Values obtained from orrection Factors on page 6. orrection factor = 0.95 x 0.93 x 1 x 0.88 = 0.78 Max. coefficient value is 1.5. orrection factor is 1.5 when the calculation result is 1.5 or greater. orrected air flow capacity = 0.4 m 3 /min (0.95 x 0.93 x 1 x 0.88) = 0.51 m 3 /min ccording to the corrected air flow capacity of 0.51 m 3 /min, the IDU4E will be selected which air flow capacity is 0.57 m 3 /min at 60 Hz. Refer to pages 22 and 25. 5

7 Selection IDF/IDU Series orrection Factors Data : Inlet ir Temperature IDF Series IDF1E to 37E IDF55E, 75E, 190D to 240D IDF100F to 150F Inlet air temp. [ ] Data B: mbient Temperature * 1 IDF Series IDF1E to 75E Data : Outlet ir Pressure Dew Point IDF Series IDF1E to 75E, 190D to 370D IDF100F to 150F IDU Series IDU3E to IDU37E IDU55E, 75E Data E: ir Flow apacity IDF Series orrection factor 5 to mbient temp. [ ] orrection factor 2 to Outlet air pressure dew point [ ] orrection factor Outlet air pressure dew point [ ] orrection factor Inlet air temp. [ ] Outlet air pressure dew point [ ] orrection factor 5 to Inlet air temp. [ ] IDF370D Data D: Inlet ir Pressure * In the case of the Option (cool compressed air output), the air flow capacity is different. Refer to page 28 for details. IDU Series IDU3E to IDU37E IDU55E, 75E IDU Series IDF100F to 150F IDF190D to 240D IDU3E to IDU37E IDU55E, 75E mbient temp. [ ] orrection factor 2 to orrection factor Outlet air pressure dew point [ ] orrection factor IDF Series IDF1E to 75E orrection factor 5 to Inlet air orrection pressure [MPa] factor to Inlet air temp. [ ] IDF100F to 150F orrection factor 5 to mbient temp. [ ] orrection factor 2 to Inlet air orrection pressure [MPa] factor to *1 For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45. IDF190D to 370D Inlet air temp. [ ] orrection factor 5 to mbient temp. [ ] orrection factor 2 to Inlet air orrection pressure [MPa] factor Inlet air temp. [ ] orrection factor 5 to mbient temp. [ ] orrection factor 2 to IDU Series IDU3E to 37E IDU55E, 75E Inlet air pressure [MPa] orrection factor to Inlet air pressure [MPa] orrection factor to IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDF15E1 IDF22E IDF37E IDF55E IDF75E ir flow capacity 50 Hz [m 3 /min (NR)] 60 Hz ir flow capacity [m 3 /min (NR)] IDF100F IDF125F IDF150F IDF190D IDF240D IDF370D 50 Hz Hz Selection IDF F IDF D Optional ccessories IDU Series IDU3E IDU4E IDU6E IDU8E IDU11E IDU15E1 IDU22E IDU37E IDU55E IDU75E ir flow capacity 50 Hz [m 3 /min (NR)] 60 Hz Specific Product Precautions

8 Standard Inlet ir Temperature IDF le Series 1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1 (Inlet air temperature: 35, Outlet air pressure dew point: 10 ) How to Order Size Symbol ir compressor size *1 1E 0.75 kw 2E 1.5 kw 3E 2.2 kw 4E 3.7 kw 6E 5.5 kw 8E 7.5 kw 11E 11 kw 15E1 15 kw *1 Note that the above values are for reference only. heck the actual compressor capacity. IDF 8E 10 Nil G K L M R S T Symbol Voltage Single-phase 100 V (50Hz) 100/110 V (60Hz) Single-phase 200 V (50Hz) 200/220 V (60Hz) Voltage pplicable size 1E 2E 3E 4E 6E 8E 11E 15E1 V V V V V V V V V V V V V V Symbol *1 Nil G K L M R S T With hinese Moderate pressure With a heavy-duty With an Power supply With a terminal Description ool nti-corrosive labels and specification * None compressed treatment for auto drain With a earth terminal block block for power (applicable to motor type connection supply, a hinese uto drain bowl: Metal air output copper tube moderate leakage operation manual bowl with level gauge auto drain (Voltage symbol operating, and Size pressure) breaker 10 only) * 3 error signals * 4 1E V V V V V 2E V V V V V 3E V V V V V 4E V V V V V V V V V 6E V V V V V V V V V V 8E V V V V V V V V V V 11E V V V V V V V V V V 15E1 V V V V V V V V V V *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Voltage symbol 20 (200 V) is the terminal block connection as standard. The Option S cannot be chosen. Voltage symbol 10 (100 V) is the power cable with plug as standard. *4 To users who are considering switching from the previous air dryer: When switching from the previous air dryer and remote operation are required, select the Made to Order (IDFlE-l-X256) product. * Refer to pages 28 to 32 for further information on options. 7

9 Refrigerated ir Dryer IDF le Series Standard Specifications Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 7. *6 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *7 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. Replacement Parts IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDF15E1 uto drain replacement parts no. *8 D37 D38 D48 *8 The part number for the auto drain components only excluding the body part. Body Body part replacement is not possible. uto drain Humid, hot air coming into the air dryer will be cooled down by a cooler (heat exchanger). Water condensed at this time will be removed from the air by a drain separator (auto drain) and drained out automatically. ir separated from the water will be heated by a re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side. IDF1E Drain separator ompressed air inlet ooler Re-heater ondenser Pressure switch apillary tube Drain outlet Volume control valve ompressed air outlet ompressor for refrigeration Evaporation thermometer Fan motor Standard inlet air temperature Specifications IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDF15E1 Fluid ompressed air Inlet air temperature [ ] 5 to 50 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 40 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] 35 mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Operating range *3 Rated conditions *4 Electric specifications Power supply voltage (Frequency) *5 IDF2E, IDF3E ompressed air inlet ooler Drain outlet Drain separator ompressed air outlet Volume control valve Re-heater ondenser Fan motor ompressor for Pressure switch refrigeration apillary tube Evaporation thermometer Single-phase: 100 V (50 Hz), 100/110 V (60 Hz) *5 Single-phase: 200 V (50 Hz), 200/220 V (60 Hz) Power consumption Single-phase 100 V 180/ /202 50/60 Hz *6 [W] Single-phase 200 V 180/ / / / / /480 Operating current Single-phase 100 V 2.4/ / / / / / / /4.6 50/60 Hz *6 [] Single-phase 200 V 1.2/ / / / / /3.1 pplicable earth leakage 10 (100 V) breaker capacity *7 [] 10 (100 V), 5 (200 V) (Sensitivity of leak current of 30 m) 10 (200 V) ondenser ir-cooled Refrigerant R134a (HF) Refrigerant charge [kg] uto drain Float type (Normally closed) IDF4E, IDF6E IDF8E, IDF11E, IDF15E1 ompressed air inlet ompressed air outlet Evaporation thermometer Float type (Normally open) Rc3/8 Rc1/2 Rc3/4 Rc1 Weight [kg] oating color Body panel: White 1 Base: Gray 2 pplicable air compressor output [kw] (Reference) For screw type ompressor for refrigeration Drain outlet ondenser Heat exchanger Drain separator Volume control valve apillary tube Pressure switch Fan motor 8 Selection IDF F IDF D Optional ccessories Specific Product Precautions

10 IDF le Series IDF1E to 3E B Q E D Illuminated switch ompressed air inlet Evaporation thermometer Drain tube (O.D. ø10, length approx. 0.8 m) F G J ompressed air outlet air inlet IDF3E-20 only L P K N M [200 V specification] Power cable outlet (ø17) H [200 V specification] Terminal block [100 V specification] Power cable (Length: approx.1.9 m) IDF4E to 11E B Q E D Illuminated switch Evaporation thermometer air outlet F G ompressed air inlet ompressed air outlet L P K Drain tube (O.D. ø10, length approx. 0.8 m) 4 x ø13 N M J H [200 V specification] Terminal block [100 V specification] Power cable (Length: approx.1.9 m) [200 V specification] Power cable outlet (ø17) B D E F G H J K L M N P Q IDF1E IDF2E Rc3/ IDF3E IDF4E Rc1/ IDF6E IDF8E Rc3/ IDF11E 9

11 Refrigerated ir Dryer IDF le Series IDF15E Illuminated switch Evaporation thermometer Drain tube (O.D. ø10, length approx. 0.8 m) x ø air outlet [100 V specification] Power cable (Length: approx.1.9 m) ompressed air outlet Rc1 ompressed air inlet Rc1 [200 V specification] Terminal block [200 V specification] Power cable outlet (ø17) Selection Specific Product Precautions Optional ccessories IDF F IDF D 10

12 Standard Inlet ir Temperature IDF le Series 22E, 37E, 55E, 75E (Inlet air temperature: 35 (22E, 37E), 40 (55E, 75E), Outlet air pressure dew point: 10 ) How to Order IDF 55E 30 Size Symbol ir compressor size *1 22E 22 kw 37E 37 kw 55E 55 kw 75E 75 kw *1 Note that the above values are for reference only. heck the actual compressor capacity. Nil G K L M R T Symbol Voltage Single-phase 200 V (50 Hz) 200/220 V (60 Hz) Three-phase 200 V (50 Hz) 200/220 V (60 Hz) Voltage pplicable size 22E 37E 55E 75E V V V V V V Size Symbol *1 Description Nil G K L M R T None With hinese Moderate pressure With a heavy-duty With an With a terminal ool nti-corrosive labels and specification * compressed treatment for auto drain With a earth block for power (applicable to motor type supply, a hinese uto drain bowl: Metal air output copper tube moderate leakage operation manual bowl with level gauge auto drain operating, and error pressure) breaker signals * 4 22E V V V V V V V V V 37E V V V V V V V V V 55E V V V V *3 V V V V 75E V V V V *3 V V V V *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Select the Option L for the 55E and 75E which need moderate pressure. *4 To users who are considering switching from the previous air dryer: When switching from the previous air dryer and remote operation are required, select the Made to Order (IDFlE-l-X256) product. * Refer to pages 28 to 32 for further information on options. 11

13 Refrigerated ir Dryer IDF le Series Standard Specifications Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) Standard inlet air temperature Specifications IDF22E IDF37E IDF55E IDF75E Fluid ompressed air Inlet air temperature [ ] 5 to 50 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 40 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Operating range *3 Rated conditions *4 Electric specifications Power supply voltage (Frequency) *5 *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 11. *6 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *7 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. Replacement Parts IDF22E IDF37E IDF55E IDF75E uto drain replacement parts no. *8 D48 *8 The part number for the auto drain components only excluding the body part. Body part replacement is not possible. Body uto drain Single-phase/Three-phase: 200 V (50 Hz) *5 Single-phase/Three-phase: 200/220 V (60 Hz) Three-phase: 200 V (50 Hz) Three-phase: 200/220 V (60 Hz) Power consumption [W] Single-phase 200 V 810/ /940 50/60 Hz *6 Three-phase 200 V 850/ / / /2500 Operating current [] Single-phase 200 V 4.3/ /4.7 50/60 Hz *6 Three-phase 200 V 3.3/ / / /8.0 pplicable earth leakage breaker capacity *7 [] 10 (200 V) 15 (200 V) (Sensitivity of leak current of 30 m) ondenser ir-cooled Refrigerant R407 (HF) Single-phase 200 V Refrigerant charge [kg] Three-phase 200 V uto drain Float type (Normally open) R1 R1 1/2 R2 Weight [kg] oating color pplicable air compressor output (Reference) For screw type Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater (heat exchanger). Water condensed at this time will be removed from the air by an auto drain and drained out automatically. ir separated from the water will be heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side. [kw] Body panel: White 1 Base: Gray Selection IDF F IDF D IDF22E, IDF37E IDF55E, IDF75E Evaporation thermometer ompressed air inlet ompressed air outlet Volume control valve ooler re-heater (Heat exchanger) Ball valve uto drain Drain outlet Optional ccessories ccumulator (IDF22E, 37E, 55E only) ompressor for refrigeration ondenser Fan motor apillary tube High pressure switch (IDF55E, 75E only) Pressure switch 12 Specific Product Precautions

14 IDF le Series IDF22E, IDF37E G ompressed air outlet ompressed air inlet B E D Illuminated switch Evaporation thermometer Ball valve air outlet F Terminal block Drain tube (O.D. ø10, length approx. 0.8 m) J L P K H uto drain Power cable holder 4 x ø13 (Electric wire diameter ø9 to ø11) [opposite side] N M IDF55E, IDF75E R G Q ompressed air inlet ompressed air outlet B E D Illuminated switch Evaporation thermometer air outlet Ball valve Terminal block uto drain F L P K Drain tube (O.D. ø10, length approx. 1 m) J H N Power cable holder (Electric wire diameter ø9 to ø11) [opposite side] M 4 x ø13 B D E F G H J K L M N P Q R IDF22E R IDF37E R1 1/ IDF55E R IDF75E

15 IDF100F/125F/150F Series pplicable ompressor Size: 100 kw, 125 kw, 150 kw (Max. inlet air temperature: 60, Max. ambient temperature: 45 ) Selection ir-cooled Size Size ir compressor size *1 100F 100 kw 125F 125 kw 150F 150 kw IDF 100F 30 *1 Note that the above values are for reference only. heck the actual compressor capacity. Voltage Symbol Voltage Three-phase V (50 Hz) 200/220 V (60 Hz) Symbol *1 Description Nil None nti-corrosive treatment for copper tube G With hinese labels and a hinese operation manual K Moderate pressure specification (Up to 1.6 MPa) P With a metal name plate R With an earth leakage breaker V With a timer controlled solenoid valve type auto drain *1 When multiple options are combined, indicate symbols in alphabetical order. * terminal block for remote operation, stop, operating, and error signals is included as standard equipment. * Refer to pages 28 to 32 for further information on options. Water-cooled IDF 100F 30 Size Size ir compressor size *1 100F 100 kw 125F 125 kw 150F 150 kw *1 Note that the above values are for reference only. heck the actual compressor capacity. Voltage Symbol Voltage Three-phase V (50 Hz) 200/220 V (60 Hz) Option Symbol *1 Description Nil None nti-corrosive treatment for copper tube G With hinese labels and a hinese operation manual K Moderate pressure specification (Up to 1.6 MPa) P With a metal name plate R With an earth leakage breaker V With a timer controlled solenoid valve type auto drain *1 Enter alphabetically when multiple options are combined. * terminal block for remote operation, stop, operating, and error signals is included as standard equipment. * Refer to pages 28 to 32 for further information on options. How to Order Nil G K P R V Nil G K P R V Nil Heat exhausting Symbol Description Nil Heat exhaust from the rear 1 Heat exhaust from the right *1 2 Heat exhaust from the left *1 3 Heat exhaust from the top *1 *1 The combination of 1, 2 and 3 is not available. (Heat exhausting face can be specified on one side only.) W Left: Piping Symbol Description 4 Facility water piping : Right *1 5 Facility water piping : Left *1 *1 The combination of 4 and 5 is not available. (Piping can be specified on one side only.) Left: 5 Top: 3 ooling method Symbol ooling method W Water-cooled condenser Right: 1 Rear: Nil Right: 4 14 IDF F IDF D Optional ccessories Specific Product Precautions

16 IDF100F/125F/150F Series Standard Specifications: ir-cooled Type Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) Specifications IDF100F-30 IDF125F-30 IDF150F-30 Fluid ompressed air Inlet air temperature [ ] 5 to 60 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 45 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] 40 mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Exhaust heat from condenser (50/60 Hz) [kw] 8.0/ / /15.0 ir dryer outlet air temperature [ ] 37 Power supply voltage (Frequency) Three-phase 200 V (50 Hz), 200/220 V (60 Hz) Power consumption [kw] 50/60 Hz *5 2.9/ / /4.8 Operating current *5 [] 50/60 Hz 10.5/ / /16.0 Operating range *3 Rated conditions *4 Electric specifications pplicable earth leakage capacity *6 [] (Sensitivity of leak current of 30 m) 30 Refrigerant R407 (HF) Refrigerant charge [kg] uto drain Heavy-duty auto drain (Normally open) R2 JIS Flange 65 10K JIS Flange 80 10K Weight [kg] oating color Body panel: White 1 Base: Gray 2 pplicable air compressor output (Reference) For screw type [kw] *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *6 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. Replacement Parts ir dryer model IDF100F IDF125F IDF150F Heavy-duty auto drain replacement part no. *7 DH-E400 Dustproof filter set for condenser IDF-FL219 IDF-FL220 *7 Part number of only the exhaust mechanism replacement kit excluding the housing * terminal block for remote operation, stop, operating, and error signal is included as standard equipment. Exhaust mechanism replacement kit Housing (Use existing equipment.) Pressure switch High pressure switch ondensed pressure gauge Filter dryer apillary tube Evaporation thermometer 15 IDF100F, IDF125F, IDF150F ondenser Fan motor ir pressure gauge Low pressure switch ompressor for refrigeration ompressed air outlet ooler re-heater Volume control valve Drain outlet ompressed air inlet Second re-heater Ball valve uto drain Hot and humid air entering the air dryer is cooled down by the cooler re-heater (heat exchanger). The moisture which is condensed and separated is automatically exhausted by the auto drain. The air which has had its moisture removed is heated in two stages by the re-heater (heat exchanger) in the cooler reheater and by the second re-heater, and is supplied to the outlet side as warm and dry air. Second re-heater ompressed air from which drainage has been exhausted exchanges heat with refrigerant which has been compressed by the compressor for refrigeration, to give the following effects: 1. The outlet air temperature increases, preventing condensation of the piping on the outlet side. 2. The amount of heat exhausted from the condenser is reduced. 3. Energy saving operation of the air dryer is achieved by reducing the amount of heat exhausted from the condenser.

17 Refrigerated ir Dryer IDF100F/125F/150F Series Standard Specifications: Water-cooled Type Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) IDF100F-W IDF125F-W IDF150F-W High pressure switch ondensed pressure gauge apillary tube ompressor for refrigeration Evaporation thermometer Filter dryer Ball valve Low pressure switch ompressed air inlet ooler re-heater Pressure type water regulating valve Facility water outlet ir pressure gauge ondenser Facility water inlet Y-shaped strainer Volume control valve Ball valve uto drain Operating range *3 Rated conditions Electric specifications Drain outlet Specifications IDF100F-30-W IDF125F-30-W IDF150F-30-W Fluid ompressed air Inlet air temperature [ ] 5 to 60 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 45 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] 40 mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 ir dryer outlet air temperature [ ] 37 Facility water flow rate *4 (50/60 Hz) [m 3 /h] 1.29/ / /2.52 Facility water inlet temperature [ ] 32 Facility water pressure drop *5 (50/60 Hz) [MPa] 0.07/0.1 ooling tower capacity *6 [kw(rt)] 9 (2) 11.5 (2.5) 14.5 (3.2) Recommended chiller model *6 (made by SM) HRS100- HRS150- Power supply voltage (Frequency) Three-phase 200 V (50 Hz), 200/220 V (60 Hz) Power consumption [kw] 50/60 Hz *7 2.4/ / /3.3 Operating current [] 50/60 Hz *7 8.5/ / /11.5 Facility water pressure range [MPa] 0.2 to 0.98 Required facility water flow rate (50/60 Hz) [m 3 /h] 1.29/ / /2.52 Facility water inlet temperature range [ ] 5 to 40 Facility water port size R1/2 R3/4 Facility water amount adjusting equipment Pressure type water regulating valve ondenser Plate type pplicable earth leakage capacity *8 (Sensitivity of leak current of 30 m) [] Refrigerant R407 (HF) Refrigerant charge [kg] uto drain Heavy-duty auto drain (Normally open) R2 JIS Flange 65 10K JIS Flange 80 10K Weight [kg] oating color Body panel: White 1 Base: Gray 2 pplicable air compressor output [kw] (Reference) For screw type *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure] *3 The operation range does not guarantee the use with normal air flow capacity. Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *4 The facility water flow rate that satisfies the rated conditions with a facility water inlet temperature of 32 and an output temperature of 37 ( t = 5 ) *5 These values are obtained under rated conditions with a rated facility water flow rate and a facility water inlet pressure of 0.2 MPa. *6 These values are obtained under rated conditions (1 RT = kw). *7 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *8 Product other than the Option R is not equipped with an earth leakage breaker. Exhaust mechanism Purchase an appropriate earth leakage breaker separately. replacement kit Replacement Parts ir dryer model IDF100F-W IDF125F-W IDF150F-W Heavy-duty auto drain replacement part no. *9 DH-E400 Facility water piping strainer IDF-S0406 IDF-S0418 *9 Part number of only the exhaust mechanism replacement kit excluding the housing * terminal block for remote operation, stop, operating, and error signal is included as standard equipment. ompressed air outlet Second re-heater Housing (Use existing equipment.) Hot and humid air entering the air dryer is cooled down by the cooler re-heater (heat exchanger). The moisture which is condensed and separated is automatically exhausted by the auto drain. The air which has had its moisture removed is heated in two stages by the re-heater (heat exchanger) in the cooler re-heater and by the second re-heater, and is supplied to the outlet side as warm and dry air. Second re-heater ompressed air from which drainage has been exhausted exchanges heat with refrigerant which has been compressed by the compressor for refrigeration, to give the following effects: 1. The outlet air temperature increases, preventing condensation of the piping on the outlet side. 2. The amount of heat exhausted from the condenser is reduced. 3. Energy saving operation of the air dryer is achieved by reducing the amount of heat exhausted from the condenser. 16 Selection IDF F IDF D Optional ccessories Specific Product Precautions

18 IDF100F/125F/150F Series IDF100F: ir-cooled type (When symbol 3 is specified.) air inlet x Eye bolt I.D. 25 (When symbol 2 is specified.) (When symbol 1 is specified.) Terminal block for power supply Terminal block for signal (When no symbol is specified.) air outlet Drain tube (When no symbol is specified.) Ball valve 712 ± air inlet Power cable holder (Electric wire diameter ø14 to ø18) ±1 107 Signal cable outlet (Electric wire diameter ø17 or less) Grommet with membrane Drain tube for drain pan of condensed water Drain tube (O.D. ø10, Length approx. 2 m) (an also be connected on the other side.) Heavy-duty auto drain IDF100F-W: Water-cooled type 670 (143) 335 (50) x Eye bolt I.D Facility water outlet R1/2 (When symbol 5 is specified.) Terminal block for signal Facility water inlet R1/2 (When symbol 5 is specified.) 712 ± Facility water outlet R1/2 (When symbol 4 is specified.) Terminal block for power supply Y-shaped strainer 1/2 (ccessory) Facility water inlet R1/2 (When symbol 4 is specified.) ± Signal cable outlet (Electric wire diameter Power cable holder ø17 or less) (Electric wire diameter Grommet with ø14 to ø18) membrane Drain tube 107 Ball valve Drain tube (O.D. ø10, Length approx. 2 m) (an also be connected on the other side.) Heavy-duty auto drain Drain tube for drain pan of condensed water Operating Parts Top view (ir-cooled/water-cooled) 700 ± x ø20 ir-cooled type Water-cooled type 17 Illuminated switch ir pressure gauge Evaporation thermometer ondensed pressure gauge Operating time accumulator Reset switch Filter check lamp Illuminated switch ir pressure gauge Evaporation thermometer ondensed pressure gauge Operating time accumulator 335 ompressed air inlet R ±2 20 ompressed air outlet R2

19 Refrigerated ir Dryer IDF100F/125F/150F Series IDF125F/150F: ir-cooled type (When symbol 2 is specified.) IDF125F-W/150F-W: Water-cooled type Facility water outlet (When symbol-w5 is specified.) Terminal block for signal Facility water inlet (When symbol-w5 is specified.) K (When symbol 3 is specified.) air inlet ir-cooled type air inlet M Q M Q K Operating Parts Illuminated switch ir pressure gauge Evaporation thermometer ondensed pressure gauge Operating time accumulator Reset switch Filter check lamp (When symbol 1 is specified.) G Terminal block for power supply Terminal block for signal D Power cable holder (Electric wire diameter ø18 to ø23) U T Facility water outlet (When symbol-w4 is specified.) Terminal block for power supply Y-shaped strainer (ccessory) G Facility water inlet (When symbol-w4 is specified.) Power cable holder (Electric wire diameter ø18 to ø23) Water-cooled type Illuminated switch ir pressure gauge Evaporation thermometer ondensed pressure gauge Operating time accumulator Signal cable outlet (Electric wire diameter ø17 or less) Grommet with membrane D R S Drain tube for drain pan of condensed water (When no symbol is specified.) (When no symbol is specified.) Heavy-duty auto drain Drain tube (O.D. ø10, Length approx. 2 m) (an also be connected on the other side.) B D E F G K L M O P Q R S T U Facility water inlet/outlet IDF125F JIS Flange IDF125F-W 65 10K R1/2 IDF150F JIS Flange IDF150F-W 80 10K R3/ B B Signal cable outlet (Electric wire diameter ø17 or less) Grommet with membrane ompressed air inlet L 4 x ø20 P 4 x Eye bolt I.D. 25 Drain tube Drain tube Drain tube for drain pan of condensed water 4 x Eye bolt I.D. 25 Top view (ir-cooled/water-cooled) F E 935 O Ball valve Ball valve air outlet Heavy-duty auto drain Drain tube (O.D. ø10, Length approx. 2 m) (an also be connected on the other side.) ompressed air outlet 20 M 18 Selection IDF F IDF D Optional ccessories Specific Product Precautions

20 Standard Inlet ir Temperature IDF ld Series 190D, 240D, 370D (Inlet air temperature: 40 (190D, 240D), 35 (370D), Outlet air pressure dew point: 10 ) How to Order Refrigerant R407 IDF190D to IDF370D Symbol 190D 240D 370D IDF 190D Symbol 3 9 Size ompressor size 190 kw 240 kw 370 kw Voltage Three-phase 200 V (50 Hz) 200/220 V (60 Hz) Voltage Three-phase different voltage (Built-in transformer) V 240V 380V 400V 415V 440V Nil L M R W Symbol *1 Nil L M R W Description Size nti-corrosive With a With a With an Water-cooled None treatment for heavy-duty motor type earth leakage type copper tube auto drain auto drain breaker Voltage 190D 3 V V Standard V V V 9 V V Standard V *2 240D 3 V V Standard V V V 9 V V Standard V *2 370D 3 V V V Standard V Standard 9 V V V Standard *2 Standard *1 When multiple options are combined, indicate symbols in alphabetical order. *2 Purchase an appropriate earth leakage breaker suitable for the inlet voltage separately. * Refer to pages 28 to 33 for further information on options. * The standard type (Nil) is equipped with a terminal block for remote operation, stop, operating, and error signals. 19

21 Refrigerated ir Dryer IDF ld Series Standard Specifications Water-cooled ondenser (IDF370D) Standard inlet air temperature Specifications IDF190D IDF240D IDF370D Fluid ompressed air Inlet air temperature [ ] 5 to 50 Inlet air pressure [MPa] 0.15 to 0.97 mbient temperature (Humidity) [ ] 2 to 40 (Relative humidity 85% or less) 2 to 43 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 ompressor intake 50 Hz /min] condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Power supply voltage Three-phase: 200 V (50 Hz), Three-phase: 200 V (Frequency) *5 200/220 V (60 Hz) (50/60 Hz) Power consumption [kw] Three-phase /60 Hz *6 200 V Operating current [] Three-phase /60 Hz *6 200 V pplicable earth leakage capacity *7 [] (Sensitivity of leak current of 30 m) 50 ondenser ir-cooled Water-cooled ir re-heater/ir cooler lass 2 pressure vessel Refrigerant R407 (HF) Refrigerant charge [kg] uto drain DH DM *8 80 (3B) Flange 100 (4B) Flange 150 (6B) Flange Weight [kg] Operating range *3 Rated conditions *4 Electric specifications oating color onstruction (ir/refrigerant ircuit) *1 Value with rated load when cooling water inlet temperature is 32. *2 alculated at 1 RT = kw Motor Type uto Drain Symbol pplicable air compressor output [kw] (Reference) For screw type *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 19. *6 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *7 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. *8 JIS 10K FF is used as a flange. IDF190D IDF240D IDF370D ompressed air inlet ir pressure gauge ompressed air outlet Evaporation thermometer Low pressure switch ompressor for refrigeration ondenser Body panel: White Base: Black Fan motor q ir re-heater Pressure switch w ir cooler ompressed air inlet ompressed air outlet ompressor for refrigeration ccumulator Operating panel: Sky blue Other panel (except base): White Drain apillary tube e uto drain Volume control valve High pressure switch ondensed pressure gauge (IDF240D only) Volume control valve Temperature expansion valve ondenser Shell and tube type ooling water flow rate *1 6 m 3 /h ooling tower performance *2 10 RT Water flow regulator Pressure type automatic water supply valve for water side 1 1/4 union Operating cycle IDF370D 4 times per minute for 8 seconds every one minute Power supply Power consumption 200 V 50/60 Hz 4 W Refrigerated air dryer uto drain High temperature humid air from the air compressor passes through the air re-heater q and is pre-cooled by dehumidified cool air. Then, it is cooled to the specified temperature by the air cooler w using the evaporation heat of refrigerant. t this time, the oil mist and moisture generated by condensation are automatically exhausted by the auto drain e. The cooled and dehumidified air goes back to the air re-heater q and heat is exchanged with hot air that flows into the air re-heater. It is supplied as dry warm air without sweating in the piping system. Selection IDF F IDF D ondensed pressure gauge High pressure switch Optional ccessories q ir re-heater w ir cooler Low pressure switch Evaporation thermometer Drain utomatic water supply valve Water-cooled condenser e Motor type auto drain 20 Specific Product Precautions

22 IDF ld Series IDF190D, IDF240D (80) B 100 (JIS 10K FF) D air inlet ompressed air inlet Power connection Grommet with membrane (Pilot hole ø36) 200 J Drain outlet Rc1/2 E F ompressed air outlet G 4 x ø20 H I Inlet and outlet port B D E F G H I J IDF190D JIS 10K FF 80 (3B) Flange IDF240D JIS 10K FF 100 (4B) Flange The auto drain is enclosed in the same shipping package as the main body. ustomers are required to mount the auto drain to the air dryer. IDF370D ompressed air inlet ompressed air outlet (280) (310) (JIS 10K FF 150 (6B)) (400) Power cable outlet (250) (800) ooling water outlet (Rc1 1/4) ooling water inlet (Rc1 1/4) (90) (390) (190) (210) Drain outlet Rc3/8 4 x ø20 Power Transformer Integrated Type IDF370D The power transformer marked with the voltage symbol 9 is integrated into the refrigerated air dryer. IDF190D to 240D The power transformer marked with the voltage symbol 9 is built into the main body, and the outside dimensions are the same as those with the voltage symbol Power cable outlet (38 x 98) (440) 1700 ±3 (2240) 4 x ø20 (Hole for foundation bolt) 21

23 Size Symbol Size Symbol ir compressor size *1 3E 2.2 kw 4E 3.7 kw 6E 5.5 kw 8E 7.5 kw 11E 11 kw 15E1 15 kw *1 Note that the above values are for reference only. heck the actual compressor capacity. How to Order IDU 4E 10 Voltage pplicable size 3E 4E 6E 8E 11E 15E1 Symbol *1 Nil G K L M R S T V Description With hinese Moderate pressure With a heavy-duty With a motor type Power supply terminal nti-corrosive With an With a terminal With a timer controlled solenoid labels and specification *2 auto drain auto drain block connection block for power valve type auto drain None treatment for earth leakage a hinese uto drain bowl: Metal (applicable to (Voltage symbol (Voltage symbol supply, operating, (Voltage symbol 23 only) copper tube breaker operation manual bowl with level gauge moderate pressure) 10, 20 only) 10 only) *3 and error signals (applicable to moderate pressure) 3E V V V V V V V V V V 4E V V V V V V V V V *4 V 6E V V V V V V V V V *4 V 8E V V V V V V V V V *4 V 11E V V V V V V V V V *4 V 15E1 V V V V V V V V V *4 V *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) The combination of K, L, M and V is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Voltage symbol 20 (200 V) and 23 (230 V) are the terminal block connection as standard. The Option S cannot be chosen. Voltage symbol 10 (100 V) is the power cable with plug as standard. *4 To users who are considering switching from the previous air dryer: When switching from the previous air dryer and remote operation are required, select the Made to Order (IDUlE-l-X256) product. * Refer to pages 28 to 32 for further information on options. High Inlet ir Temperature IDUlE Series 3E, 4E, 6E, 8E, 11E, 15E1 (Inlet air temperature: 55, Outlet air pressure dew point: 10 ) Voltage Single-phase 100 V (50 Hz) 100/110 V (60 Hz) Single-phase 200 V (50 Hz) 200/220 V (60 Hz) Single-phase 230 V (50 Hz) V V V V V V V V V V V V V V V V V V Nil G K L M R S T V 22 Selection IDF F IDF D Optional ccessories Specific Product Precautions

24 IDU le Series Standard Specifications Symbol Refrigerated air dryer uto drain High inlet air temperature Specifications IDU3E IDU4E IDU6E IDU8E IDU11E IDU15E1 Fluid ompressed air Inlet air temperature [ ] 5 to 80 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 40 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] 55 mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Operating range *3 Rated conditions *4 Electric specifications Power supply voltage (Frequency) *5 Single-phase: 100 V (50 Hz), 100/110 V (60 Hz) *5 Single-phase: 200 V (50 Hz), 200/220 V (60 Hz) Single-phase: 230 V ±10% (50 Hz) Power Single-phase 100 V *7 *7 *7 180/ / / / / /530 consumption [W] Single-phase 200 V 50/60 Hz *6 Single-phase 230 V (50 Hz) Operating 100 V 2.4/ / / / / /4.9 current [] 200 V 1.2/ / / / / /3.4 50/60 Hz *6 230 V (50 Hz) pplicable earth leakage breaker 10 (100 V) capacity *8 [] 10 (100 V), 5 (200 V, 230 V) (Sensitivity of leak current of 30 m) 10 (200 V) Refrigerant R134a (HF) Single-phase 100 V Refrigerant charge [kg] Single-phase 200 V Single-phase 230 V uto drain Float type (Normally open) Rc3/8 Rc1/2 Rc3/4 Rc1 Weight [kg] oating color Body panel: White 1 Base: Gray 2 pplicable air compressor output [kw] (Reference) For screw type onstruction (ir/refrigerant ircuit) *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 When selecting a power supply voltage, refer to the How to Order on page 22. *6 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *7 For the IDU8E or larger models, cooling with the aftercooler helps save energy. *8 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. Replacement Parts IDU3E IDU4E IDU6E IDU8E IDU11E IDU15E1 uto drain replacement parts no. *9 D48 *9 The part number for the auto drain components only excluding the body part. Body Body part replacement is not possible. uto drain Humid, hot air coming into the air dryer will be cooled down by a heat exchanger. Water condensed at this time will be removed from the air by a drain separator and drained out automatically. ir separated from the water will be heated by a heat exchanger to obtain the dried air, which goes through to the outlet side. For models IDU8E to 15E1, the humid and hot air introduced to the air dryer will be cooled down by the aftercooler before being cooled down by the heat exchanger. IDU3E IDU4E IDU6E 23 ompressed air inlet ompressed air outlet Evaporation thermometer ompressor for refrigeration Drain outlet ondenser Fan motor Heat exchanger Drain separator Volume control valve apillary tube Pressure switch IDU8E IDU11E IDU15E1 ompressed air inlet ompressed air outlet Evaporation thermometer ompressor for refrigeration Drain outlet ondenser Fan motor ftercooler Fan motor Heat exchanger Drain separator Volume control valve apillary tube Pressure switch

25 Refrigerated ir Dryer IDU le Series IDU3E to IDU6E B Q E D Selection L P B D E F G H J K L M N P Q IDU3E Rc3/ IDU4E Rc1/ IDU6E Rc3/ IDU8E to IDU15E1 Illuminated switch Evaporation thermometer Drain tube (O.D. ø10, length approx. 0.8 m) K Illuminated switch Evaporation thermometer 4 x ø13 air outlet [100 V specification] Power cable (Length: approx. 1.9 m) N B M F G J [200 V specification] Power cable outlet (ø17) Q air outlet H E ompressed air inlet ompressed air outlet [200 V specification] Terminal block D ompressed air inlet IDF F IDF D G F ompressed air outlet [200 V specification] Terminal block 42 L 14 4 x ø13 N M P [100 V specification] Drain tube Power cable (O.D. ø10, length approx. 0.8 m) (Length: approx. 1.9 m) B D E F G H L M N P Q IDU8E 859 Rc3/ IDU11E 909 IDU15E1 Rc H [200 V specification] Power cable outlet (ø17) 24 Optional ccessories Specific Product Precautions

26 High Inlet ir Temperature IDUlE Series 22E, 37E, 55E, 75E (Inlet air temperature: 55, Outlet air pressure dew point: 10 ) How to Order IDU 22E 30 Size Symbol ir compressor size *1 22E 22 kw 37E 37 kw 55E 55 kw 75E 75 kw *1 Note that the above values are for reference only. heck the actual compressor capacity. Nil G L M R T V Symbol Voltage Voltage Single-phase 230 V (50 Hz) Three-phase 200 V (50 Hz) 200/220 V (60 Hz) Size Symbol *1 Description Nil G L M R T V None nti-corrosive treatment for copper tube With hinese labels and a hinese operation manual With a heavy-duty auto drain (applicable to moderate pressure *2 ) With a motor type auto drain (Voltage symbol 30 only) With an earth leakage breaker With a terminal block for power supply, operating, and error signals *3 With a timer controlled solenoid valve type auto drain (Voltage symbol 23 only) (applicable to moderate pressure *2 ) 22E V V V V V V V V 37E V V V V V V V V 55E V V V V V V V V 75E V V V V V V V V *1 When multiple options are combined, indicate symbols in alphabetical order. However, the following combinations are not possible. The combination of L, M and V is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 To users who are considering switching from the previous air dryer: When switching from the previous air dryer and remote operation are required, select the Made to Order (IDUlE-l-X256) product. * Refer to pages 28 to 32 for further information on options. 25

27 Refrigerated ir Dryer IDU le Series Standard Specifications Symbol Refrigerated air dryer uto drain onstruction (ir/refrigerant ircuit) IDU22E, IDU37E, IDU55E, IDU75E High pressure switch (IDU55E, 75E only) Evaporation thermometer Volume control valve ccumulator ompressor for refrigeration ompressed air inlet ondenser Fan motor High inlet air temperature Specifications IDU22E IDU37E IDU55E IDU75E Fluid ompressed air Inlet air temperature [ ] 5 to 80 Inlet air pressure [MPa] 0.15 to 1.0 mbient temperature (Humidity) [ ] 2 to 40 (Relative humidity 85% or less) Standard condition 50 Hz ir flow (NR) *1 60 Hz capacity [m 3 /min] ompressor intake 50 Hz condition *2 60 Hz Inlet air pressure [MPa] 0.7 Inlet air temperature [ ] 55 mbient temperature [ ] 32 Outlet air pressure dew point [ ] 10 Operating range *3 Rated conditions *4 Electric specifications Power supply voltage (Frequency) *1 ir flow capacity under the standard condition (NR) [20, tmospheric pressure, and 65% Relative humidity] *2 ir flow capacity converted by the compressor intake condition [32, tmospheric pressure, and 75% Relative humidity] *3 The operation range does not guarantee the use with normal air flow capacity. *4 Select the model in accordance with Selection (pages 5, 6) for models beyond the rated specifications. *5 These values are reference values under rated conditions, and are not guaranteed. Do not use these values for the thermal set values, etc. *6 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. Replacement Parts IDU22E IDU37E IDU55E IDU75E uto drain replacement parts no. *7 D48 *7 The part number for the auto drain components only excluding the body part. Body Body part replacement is not possible. uto drain Valve ftercooler Fan motor ompressed air outlet ooler re-heater (Heat exchanger) apillary tube Pressure switch uto drain Drain outlet High pressure switch (IDU55E, 75E only) Single-phase: 230 V ±10% (50 Hz) Three-phase: 200 V (50 Hz) Three-phase: 200/220 V (60 Hz) Power consumption Three-phase 200 V 1100/ / /2850 [W] 50/60 Hz *5 Single-phase 230 V (50 Hz) Operating current Three-phase 200 V 4.2/ / /9.3 [] 50/60 Hz *5 Single-phase 230 V (50 Hz) pplicable earth leakage Three-phase 200 V breaker capacity *6 [] (Sensitivity of leak current of 30 m) Single-phase 230 V (50 Hz) Refrigerant R407 (HF) Refrigerant charge [kg] uto drain Three-phase 200 V Single-phase 230 V Float type (Normally open) R1 R1 1/2 R2 Weight [kg] oating color pplicable air compressor output [kw] (Reference) For screw type Body panel: White 1 Base: Gray Humid, hot air coming into the air dryer will be cooled down by a heat exchanger. Water condensed at this time will be removed from the air by a drain separator and drained out automatically. ir separated from the water will be heated by a heat exchanger to obtain the dried air, which goes through to the outlet side. 26 Selection IDF F IDF D Optional ccessories Specific Product Precautions

28 IDU le Series IDU22E to 75E Evaporation thermometer G Illuminated switch ompressed air outlet B E ompressed air inlet (F) Ball valve air outlet (D) Terminal block Drain tube (O.D. ø10, length approx. 1 m) J L P 13 Power cable holder (Electric wire diameter ø9 to ø11) [opposite side] H N M 4 x ø13 B D E F G H J L M N P IDU22E R IDU37E R1 1/ IDU55E R IDU75E

29 IDF/IDU Series Refer to How to Order on pages 7, 11, 14, 19, 22, 25 for optional models. Option symbol ool compressed air output ool outlet air (10 ) can be supplied. The air flow with this option is smaller than that of the standard air dryer. (Refer to the table below.) If the air dryer is used out of the scope of the rated specifications or conditions, select a model according to pages 5 and 6 and apply the air flow capacity shown in the tables below to the data E. *1 Perform thermal insulation treatment for pipings and equipment installed after the dryer to prevent the formation of condensation. *2 The Option cannot be used for the IDF100F to 370D and the IDU series due to the construction of the heat exchanger unit. (Rated conditions): Inlet air pressure: 0.7 MPa, Inlet air temperature: 35 (IDF1E to 37E), 40 (IDF55E, 75E), Outlet air temperature: 10 Option symbol nti-corrosive treatment for copper tube This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. (orrosion cannot be completely prevented.) Special epoxy coating: opper tube and copper alloy parts. The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by the coating. orrosion is not covered under warranty. G K Option symbol With hinese labels and a hinese operation manual In addition, hinese labels are put on the external panels. hinese operation manual is also included. Option symbol Moderate pressure specification (uto drain bowl: Metal bowl with level gauge) The maximum operating pressure is 1.6 MPa. The auto drain is changed from the standard to the moderate pressure specification. metal bowl with a level gauge which can confirm the water level is used for the auto drain. Specifications 1. Maximum operating pressure: 1.6 MPa 2. same as standard products Replacement Parts uto drain replacement parts no. IDF1E to 75E ir Flow apacity IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDF15E1 IDF22E IDF37E IDF55E IDF75E ir flow capacity 50 Hz [m 3 /min (NR)] 60 Hz IDF6E to 37E IDU3E to 15E1 IDF-S0086 IDF, IDU all models IDF1E to 75E, IDU3E to 75E IDF6E to 37E, IDU3E to 15E1 Note ssembly of uto drain: D48-8-X2110, One-touch fitting: KQ2H10-02S, and Insulator Selection Optional ccessories IDF F IDF D 28 Specific Product Precautions

30 IDF/IDU Series K Option symbol Moderate pressure specification The maximum operating pressure is 1.6 MPa. The internal drain piping is changed from the nylon tube to the metal. Specifications 1. Maximum operating pressure: 1.6 MPa 2. same as standard products IDF100F to 150F L Option symbol With a heavy-duty auto drain (applicable to moderate pressure) Drainage including dust can also be exhausted. The float type auto drain used in the standard air dryer is replaced with a heavy-duty auto drain (DH ). * The IDF100F to 150F, 190D, 240D standard types are equipped with a heavy-duty auto drain. Max. operating pressure: 1.6 MPa IDF4E to 15E1 IDU3E to 15E1 (207) (157) Max. operating pressure: 0.97 MPa IDF370D IDF4E to 75E, IDF370D, IDU3E to 15E1, IDU22E to 75E Ball valve () Drain outlet Rc1/2 Heavy-duty auto drain (B) 168 * The heavy-duty auto drain and the ball valve are both enclosed in the same shipping package as the main body of the air dryer. ustomers are required to mount the parts to the air dryer. * ustomers will need to supply the fitting (KQ2L10-04S) and tubing (TU1065BU) for the drain piping. Drain outlet (2 locations) 2 x Rc3/8 (210) B IDF4E 55 IDF6E, IDU3E IDF8E, IDF11E 139 IDU4E, IDU6E 378 IDU8E, IDU11E 149 IDF15E IDU15E1 533 IDF22E to 75E, IDU22E to 75E Replacement Parts: Heavy-Duty uto Drain Part no. (Description) onfiguration IDF4E to 15E1 IDU3E to 15E1 IDF370D IDF22E to 75E IDU22E to 75E DH (Heavy-duty auto drain) DH-E400 (Exhaust mechanism replacement kit) Heavy-duty auto drain Exhaust mechanism replacement kit Housing (Use existing equipment.) Ball valve Drain tube: Length approx m (O.D. ø10) Heavy-duty auto drain (ssembled before shipment) IDF22E, 37E IDU22E, 37E pprox. 100 IDF55E, 75E IDU55E pprox. 120 IDU75E pprox

31 IDF/IDU Series M Option symbol With a motor type auto drain The float type auto drain used in the standard air dryer is replaced with a motor type auto drain (DM200). * The IDF370D standard type is equipped with a motor type auto drain. IDF4E to 75E, 190D, 240D IDF3E to 75E Selection ir Discharge Operating air pressure ir discharge without drainage 0.3 MPa m 3 per cycle (NR) 0.5 MPa m 3 per cycle (NR) 0.7 MPa m 3 per cycle (NR) The motor type auto drain actuates for 2 seconds per cycle. The operating cycle is as follows. IDF4E to 75E, IDU3E to 37E: Once per minute, IDU55E, 75E: Twice per minute, IDF190D to 370D: 4 times per minute. IDF4E to 15E1 IDU3E to 15E1 Drain outlet (B) Rc3/8 B D IDF4E IDF6E, IDU3E 166 IDF8E, 11E IDU4E, 6E IDU8E, 11E IDF15E IDU15E * The motor type auto drain and the ball valve are both enclosed in the same shipping package as the main body of the air dryer. ustomers are required to mount the auto drain to the air dryer. * ustomers will need to supply the fitting (KQ2L10-03S) and tubing (TU1065BU) for the drain piping. IDF22E to 75E IDU22E to 75E Ball valve (D) () () Ball valve Motor type auto drain Motor type auto drain (ssembled before shipment) Drain tube: Length approx m (O.D. ø10) IDF190D, 240D IDF190D 526 IDF240D 565 (131) (68) Replacement Parts: Motor Type uto Drain ssembly * 1 Part no. Note IDF4E to 15E1-10 IDU3E to 15E1-10 IDF4E to 37E-20 IDF22E to 75E-30 IDU3E to 15E1-20 IDU22E, 37E-30 IDU55E, 75E IDF190D, 240D IDF-S0087 IDF-S0090 IDF-S0510 IDF-S0511 *1 Including electric wire with connector on the end Motor type auto drain Drain outlet Rc3/8 () * The motor type auto drain is enclosed in the same shipping package as the main body of the air dryer. ustomers are required to mount the auto drain to the air dryer. ssembly of Motor type auto drain: DM , Plug housing assembly: , Receptacle: , Rubber plug: ssembly of Motor type auto drain: DM , Plug housing assembly: , Receptacle: , Rubber plug: ssembly of Motor type auto drain: DM , Plug housing assembly: , Receptacle: , Rubber plug: ssembly of Motor type auto drain: DM , Plug housing assembly: , Receptacle: , Rubber plug: IDF F IDF D * When a longer drain tube than the one attached is necessary, remove and replace it with a tube prepared by customers. (fter connection with a fitting, the drain may not flow due to a drop in pressure caused by the fitting.) P Option symbol With a metal name plate IDF100F to 150F The label identifying the model and specifications of the product is changed to a metal plate which has better endurance. 30 Optional ccessories Specific Product Precautions

32 IDF/IDU Series R Option symbol With an earth leakage breaker The air dryer is equipped with an earth leakage breaker, reducing the electrical wiring required during installation. (The IDF370D does not include the electrical leakage detection function.) IDF190D, 240D IDF4E to 15E1 IDU3E to 15E1 () 60 D 40 Earth leakage breaker Except IDF1E, 2E, 3E IDF370D () No-fuse breaker E B Power cable outlet (ø17) Grommet with membrane B D E IDF4E, 6E, 8E, 11E IDF15E IDU3E, 4E, 6E Earth leakage breaker IDU8E with cover IDU11E 75 IDU15E IDF22E to 75E IDF190D IDU22E to 75E IDF240D 95 IDF370D 156 Power connection ø35 B D Earth leakage breaker E Power cable outlet (ø17) F (Electric wire diameter ø9 to ø11) [opposite side] B D E F IDF22E IDF37E IDF22E IDF37E IDF55E IDF75E IDU22E IDU37E IDU55E IDU75E IDF100F to 150F Breaker apacity and Sensitivity of Leak urrent Voltage 100 V type 200 V type Breaker capacity IDF4E-10, IDF6E-10 IDF8E-10, IDF11E-10, IDF15E IDU3E-10, IDU4E-10, IDU6E-10 IDU8E-10, IDU11E-10, IDU15E1-10 IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 5 IDU3E-20, IDU4E-20 IDU6E-20, IDU8E-20, IDU11E-20 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 IDF75E-30, IDU75E IDF100F IDF125F 30 IDF150F IDF190D IDF240D 50 Sensitivity of leak current 30 m IDF370D B B IDF100F 434 IDF125F IDF150F

33 IDF/IDU Series S Power supply terminal block connection The option allows the connection of a power cable to a terminal block. This option is supplied with the 200 V model as a standard accessory. IDF1E-10 to 3E-10 B IDF4E, 6E, 8E, 11E IDF15E IDU3E, 4E, 6E IDU8E, 11E IDU15E T Option symbol Power outlet (ø17) Grommet with membrane (98) IDF4E-10 to 15E1-10 IDU3E-10 to 15E1-10 Power cable outlet (ø17) Grommet with membrane (33) Option symbol With a terminal block for power supply, operating, and error signals IDF1E-10 to 15E1-10, IDU3E-10 to 15E1-10 In addition to power supply connection, entry of operating and error signals is available. (No-voltage contact) dditionally, when using the remote operation, select the Made to Order (IDF8E to 15E1- -X256, IDU8E to 15E1- -X256) products. IDF4E to 15E1 IDU3E to 15E1 Terminal block B 53 Terminal block Terminal block IDF4E to 15E1, IDU3E to 15E1 Signal cable outlet (ø17) Grommet with membrane T In addition to power supply connection, entry of operating and error signals is available. (No-voltage contact) dditionally, when using the remote operation, select the Made to Order (IDF22E to 75E- -X256, IDU22E to 75E- -X256) products. IDF22E to 75E, IDU22E to 75E ontact capacity: Operating signal 220 V, 6 Error signal 250 V, 7 Minimum current value: 20 V, 5 m (/D) for operating and error signals B D IDF22E, 37E IDF55E, 75E IDU22E, 37E IDU55E IDU75E V Option symbol With a terminal block for power supply, operating, and error signals Power cable holder (Electric wire diameter ø9 to ø11) Option symbol B D Signal cable outlet (Electric wire diameter ø17) Grommet with membrane With a timer controlled solenoid valve type auto drain (applicable to moderate pressure) IDF22E to 75E, IDU22E to 75E IDU3E to 75E-23 IDF100F to 150F Drainage is discharged by controlling a solenoid valve with a timer. strainer for solenoid valve protection and a stop valve are also included. (The external dimensions are the same as the standard product.) Maximum operating pressure: 1.6 MPa (IDF100F to 150F: 1.0 MPa) Terminal block The timer controlled solenoid valve actuates once (for 0.5 seconds) every 30 seconds. Selection IDF F IDF D D B Power cable outlet (ø17) Grommet with membrane ontact capacity: Operating signal 220 V, 6 Error signal 250 V, 7 Minimum current value: 24 V, 5 m (/D) for operating and error signals * Be sure to confirm the electric circuits with the drawings or Operation Manual before using the operating and error signals. B D IDF4E, 6E, 8E, 11E IDF15E IDU3E, 4E, 6E IDU8E, 11E IDU15E Replacement Parts Part no. Note IDU3E to 37E-23 IDF-S0198 IDU55E, 75E-23 IDF-S V IDF100F to 150F IDF-S V 32 Optional ccessories Specific Product Precautions

34 IDF/IDU Series W Option symbol Water-cooled type IDF100F to 150F, 190D, 240D It can be used in a high temperature environment without decreasing air flow capacity. It can also be used in an enclosed environment without increasing the ambient temperature. This option is supplied with the IDF370D as a standard accessory. IDF100F IDF125F IDF150F IDF190D IDF240D ondenser Plate system Shell and coil system ooling water flow rate [m / / / / /5.4 /h] *1 50/60 Hz ooling tower performance [RT] *2 Water flow regulator Pressure type automatic water supply valve for water side R1/2 R3/4 R1 *1 Value with rated load when cooling water inlet temperature is 32. *2 alculated at 1 RT = 3300 kcal/h IDF100F to 150F B B IDF100F 384 IDF125F, 150F IDF190D, 240D B ooling water outlet ondensation pressure gauge E ooling water inlet D Drain plug Rc3/8 B D E IDF190D, 240D

35 IDF/IDU Series Optional ccessories Specifications Description Features Specifications pplicable air dryer Separately installed Max. ambient temperature IDF1E-10 to IDF15E1-10, IDF22E-20/30 power transformer *1, 2 Power supply and voltage for those IDF37E-20/30, IDF55E-30, IDF75E other than the standard. IDU3E-10 to 15E1-10, IDU22E to 75E-30 (Relative humidity 85% or less) IDF100F to 150F, IDF190D to 370D-3 p. 36, 37 Dedicated base for separately installed power transformer *2 Dust-protecting filter set * 3 Bypass piping set Foundation bolt set Piping adapter Mounting base adapter onversion piping set onversion bypass piping set *1 When using a power transformer for the IDF1E to 15E1 and IDU3E to 15E1, select the air dryer of 100 V. *2 When using a power transformer for the IDF190D and 240D, built-in transformer type is also available. (Refer to the How to Order on page 19.) *3 This filter set is supplied with the IDF100F to 150F as a standard accessory. *4 Not applicable to the moderate pressure specification. Prepare a bypass, conversion or conversion bypass piping set suitable for the specification. How to Order Separately installed power transformer is not attached. Order separately. [Separately installed power transformer] Single-phase type IDF TR apacity Symbol pplicable air dryer apacity 500 IDF1E-10 to IDF8E-10 IDU3E-10, IDU4E-10, IDU8E V 1000 IDF11E-10, IDF15E1-10 IDU6E-10, IDU11E-10, IDU15E kv 2000 IDF22E-20, IDF37E-20 2 kv Three-phase type IDF TR apacity Symbol pplicable air dryer apacity 1700 IDF22E-30, IDF37E-30 IDU22E-30, IDU37E kv 4000 IDF55E-30, IDF75E-30 IDU55E-30, IDU75E-30 4 kv 7000 IDF100F 7 kv 9000 IDF125F, 150F 9 kv IDF190D, 240D 14 kv IDF370D 18 kv For integrating the separately installed power transformer and the air dryer. For preventing a decline in the performance of air dryers, even in a dusty atmosphere. Easy bypass piping (connect this set to the air dryer), allowing substantial reduction in the installation time. For fixing the air dryer to the foundations. Easy to secure by striking the axle. For converting the thread type of an IN/OUT fitting for air dryers. For ensuring conversion to the former models (IDF22 and 37) air piping. [When bypass piping is already in place] For ensuring conversion to the former models (IDF6D to 15) air piping. [When there is no bypass piping] For ensuring conversion to the former models (IDF6D to 15) air piping. * Refer to pages 36 and 37 for dimensions. Power supply voltage Symbol Inlet voltage Outlet voltage Type V (50 Hz) 110 to 120 V (60 Hz) 2 200, 220, 230, 240 V (50 Hz) 100 V (50 Hz) 200 to 260 V (60 Hz) Singlephase 100, 110 V 3 380, 400, 415 V (50 Hz) 380 to 420 V (60 Hz) (60 Hz) 4 420, 440, 480 V (50 Hz) 420 to 520 V (60 Hz) V (50 Hz) 220 to 240 V (60 Hz) 200 V (50 Hz) Singlephase , 400, 415 V (50 Hz) 380 to 400, 400 to 415, 415 to 440 V (60 Hz) 200, 220 V (60 Hz) , 460 V (50 Hz) 440 to 460, 460 to 500 V (60 Hz) Power supply voltage Symbol Inlet voltage Outlet voltage Type V (50 Hz) 220 to 240 V (60 Hz) 200 V (50 Hz) 6 380, 400, 415 V (50 Hz) 380 to 440 V (60 Hz) 200, 220 V Threephase (60 Hz) 7 440, 460 V (50 Hz) 440 to 500 V (60 Hz) 8 220, 240, 380, 400, 415, 440 V (50/60 Hz) 200 V (50/60 Hz) * Refer to page 37 for dimensions. Max. ambient temperature 40 Max. operating pressure *4 1.0 MPa Max. operating temperature IDF: 60 IDU: 80 Stainless steel Brass IDF4E to 15E1-10 IDF22E-20/30, IDF37E-20/30 IDF55E-30, IDF75E-30 IDU3E to 15E1-10 IDF1E to 75E IDF190D to 240D IDU3E to 75E IDF1E to 75E IDU3E to 75E IDF4E to 75E IDU3E to 75E IDF100F to 150F IDF1E to 75E IDU3E to 75E IDF100F to 150F IDF22E, 37E Max. operating pressure *4 1.0 MPa Max. operating temperature 60 Max. operating pressure *4 1.0 MPa Max. operating temperature 60 IDF6E to 15E1 p. 38 p. 39 p. 40, 41 p. 41 p. 42 IDF6E to 15E1 p Selection IDF F IDF D Optional ccessories Specific Product Precautions

36 IDF/IDU Series How to Order [Dedicated base for separately installed power transformer] IDF Size Symbol pplicable air dryer 403 IDF4E to 11E, IDU3E to 6E 404 IDF15E1 405 IDF22E 406 IDF37E 409 IDF55E, IDF75E TB 403 IDU TB 407 Size Symbol pplicable air dryer 407 IDU8E, IDU11E 408 IDU15E1 410 IDU22E 411 IDU37E * Not available for the IDF1E to 3E, IDU55E, 75E, IDF100F to 150F, IDF190D, 240D, 370D. In the case of the Option S, the part number will be different. Please consult with SM separately. Refer to page 38 for dimensions. [Dust-protecting filter set] IDF FL 201 IDF FL 190 D IDU FL 210 pplicable air dryer Symbol pplicable air dryer 200 *1 IDF1E, 2E 201 *1 IDF3E 202 IDF4E 203 IDF6E, IDU3E 204 IDF8E, IDU4E 205 IDF11E, IDU6E 206 IDF15E1 207 IDF22E 208 IDF37E 213 IDF55E 214 IDF75E pplicable air dryer Symbol pplicable air dryer 190 IDF190D 240 IDF240D *1 This filter set is supplied with the IDF100F to 150F as a standard accessory. Refer to page 39 for dimensions. pplicable air dryer Symbol pplicable air dryer 210 IDU8E 211 IDU11E 212 IDU15E1 215 IDU22E 216 IDU37E 217 IDU55E 218 IDU75E [Bypass piping set (Rc, R thread)] IDF BP 302 IDU BP 305 [Foundation bolt set] IDF B 500 pplicable air dryer Symbol pplicable air dryer Thread type 300 IDF1E 301 IDF2E 302 IDF3E 303 IDF4E Rc 304 IDF6E to 11E 316 IDF15E1 317 IDF22E 318 IDF37E R IDF55E 325 IDF75E * Not applicable to the moderate pressure specification (maximum operating pressure 1.6 MPa). Prepare a bypass piping set suitable for the specification by customers. [Piping adapter] IDF P 601 pplicable air dryer Symbol pplicable air dryer 305 IDU3E 306 IDU4E 307 IDU6E 320 IDU8E, IDU11E 322 IDU15E1 336 IDU22E 337 IDU37E 338 IDU55E, IDU75E * Refer to pages 40 and 41 for bypass piping set dimensions. pplicable air dryer Thread type and port size Symbol Male thread side Female thread B side pplicable air dryer 601 R1/2 NPT1/2 IDF4E, IDU4E 603 R3/4 NPT3/4 IDF6E to 11E, IDU6E to 11E 604 NPT1 Rc1 IDF22E, IDU22E 605 R1 NPT1 IDF15E1, IDU15E1 606 NPT1 1/2 Rc1 1/2 IDF37E, IDU37E 607 NPT2 Rc2 IDF100F to 150F 609 R3/8 NPT3/8 IDF1E to 3E, IDU3E * Refer to page 41 for dimensions. 35 pplicable air dryer Symbol pplicable air dryer IDF4E to 75E 500 IDU3E to 15E1 IDF100F to 150F 501 IDU22E to 75E * Refer to page 41 for dimensions. [Mounting base adapter] pplicable to the IDF22E and 37E. Part no. pplicable air dryer IDF-S0189 IDF22E IDF-S0147 IDF37E * Refer to page 42 for dimensions. [onversion piping set/ onversion bypass piping set] pplicable to the IDF6E to 15E1. Select onversion Piping Set when bypass piping is already in place, and onversion Bypass Piping Set when there is no bypass piping. Part no. pplicable air dryer onversion piping set onversion bypass piping set IDF-S0186 IDF-S0183 IDF6E IDF-S0203 IDF-S0202 IDF8E IDF-S0187 IDF-S0184 IDF11E IDF-S0188 IDF-S0185 IDF15E1 * Refer to pages 42 and 43 for dimensions.

37 Optional ccessories IDF/IDU Series Specifications/ [Separately installed power transformer] IDF-TR 1 Selection B OUT PUT IN PUT 4 x F D IDF-TR 2 Input cable 2 m B E Specifications/ Part no. pplicable air dryer apacity Type IDF-TR500-1 IDF-TR IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10 IDF11E-10, 15E1-10 IDU6E-10, 11E-10, 15E1-10 Inlet voltage Outlet voltage B D E F Weight 500 V Singlephase (Long hole) 110 V 100 V (50 Hz) (50 Hz) x kg 110 to 100, Singleturn kg 120 V 110 V 4.2 x 9 1 kv (60 Hz) (60 Hz) (Long hole) IDF F D IDF-TR 3, 4 4 x 6.5 x 12 Long hole Specifications/ E Part no. pplicable air dryer apacity Type IDF-TR500-2 IDF-TR IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10 IDF11E-10, 15E1-10 IDU6E-10, 11E-10, 15E1-10 Inlet voltage Outlet voltage B D E Weight 500 V Singlephase 100 V kg 200, , 240 V Singleturn (50/60 Hz) (50/60 Hz) 1 kv kg IDF D FUSE OUT PUT D VOLTGE SELETOR IN PUT B 4 x øf Input cable 2 m E Specifications/ Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage B D E F Weight IDF1E-10 to 8E-10 IDF-TR V 380, 400, IDU3E-10, 4E-10, 8E V (50 Hz) 15 kg 380 to IDF11E-10, 15E1-10 IDF-TR Singlephase (50 Hz) 420 V (60 Hz) 100 V IDU6E-10, 11E-10, 15E kv Singleturn (60 Hz) 110 V IDF1E-10 to 8E-10 IDF-TR V 420, 440, IDU3E-10, 4E-10, 8E V (50 Hz) 22 kg 420 to IDF11E-10, 15E1-10 IDF-TR V (60 Hz) IDU6E-10, 11E-10, 15E kv 36 Optional ccessories Specific Product Precautions

38 IDF/IDU Series Specifications/ [Separately installed power transformer] IDF-TR Terminal block ø30 IDF-TR1700-6, x ø8 243 ø39 able hole Terminal block IDF-TR x ø ø26 able hole 15 Specifications Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage Weight IDF-TR IDF-TR IDF22E-30 IDF37E-30 IDU22E-30 IDU37E kv 380, 400, 415 V (50 Hz) 380 to 400, 400 to 415, 415 to 440 V (60 Hz) 440, 460 V (50 Hz) 440 to 460, 460 to 500 V (60 Hz) 200 V (50 Hz) 200, 220 V (60 Hz) 18 kg Terminal block 4 x ø IDF-TR ,11 Terminal block 243 ø39 able hole x ø IDF-TR4000-5,6,7 ø30 IDF-TR 8 B 45 4 x ø11 Terminal block Specifications Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage Weight 140 IDF22E-20 IDF-TR kv Single-phase 220 V (50 Hz) 200 V (50 Hz) 5 kg IDF37E-20 Single-turn 220 to 240 V (60 Hz) 200, 220 V (60 Hz) E Specifications Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage Weight IDF-TR IDF-TR IDF22E-20 IDF37E-20 IDF55E-30 IDF75E-30 IDU55E-30 IDU75E-30 2 kv 4 kv Specifications Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage Weight IDF22E-30 Threephase 220 V (50 Hz) 200 V (50 Hz) 190 IDF37E-30 IDF-TR kv 9 kg IDU22E-30 Singleturn 220 to 240 V (60 Hz) 200, 220 V (60 Hz) IDU37E-30 Threephase Singleturn Singlephase Singleturn Threephase Singleturn 380, 400, 415 V (50 Hz) 380 to 400, 400 to 415, 415 to 440 V (60 Hz) 440, 460 V (50 Hz) 440 to 460, 460 to 500 V (60 Hz) 200 V (50 Hz) 200, 220 V (60 Hz) 20 kg Specifications/ Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage B Weight 220 V (50 Hz) 200 V (50 Hz) IDF-TR kg 220 to 240 V (60 Hz) 200, 220 V (60 Hz) IDF-TR IDF-TR , 400, 415 V (50 Hz) 380 to 400, 400 to 415, 415 to 440 V (60 Hz) 440, 460 V (50 Hz) 440 to 460, 460 to 500 V (60 Hz) 200 V (50 Hz) 200, 220 V (60 Hz) 200 V (50 Hz) 200, 220 V (60 Hz) kg kg 37 øg 4 x øf B D Specifications/ Part no. pplicable air dryer apacity Type Inlet voltage Outlet voltage B D E F G Weight IDF-TR IDF100F 7 kv Threephase 380, 400, 200 V kg 220, 240, kg IDF-TR IDF125F, 150F 9 kv IDF-TR IDF190D, 240D 14 kv Doubleturn 440 V (50/60 Hz) , (50/60 Hz) kg IDF-TR IDF370D 18 kv kg

39 Optional ccessories IDF/IDU Series [Dedicated base for separately installed power transformer] IDF4E to 75E IDU3E to 37E IDF-TBl/ IDU-TBl/ 15 E D B 4 x ø13 Separately installed power transformer 75 F 65 (125: For IDF55E, 75E) G Dedicated base for separately installed power transformer Part no. pplicable air dryer pplicable transformer B D E F G Unit weight Reference weight [kg] (including air dryer and transformer) [kg] IDF-TR IDF-TR IDF4E-10 IDF-TR IDF-TR IDF-TR IDF6E-10 IDF-TR IDU3E-10 IDF-TR IDF-TR IDF-TB IDF-TR IDF8E-10 IDF-TR IDU4E-10 IDF-TR IDF-TR IDF-TR IDF11E-10 IDF-TR IDU6E-10 IDF-TR IDF-TR IDF-TR IDF-TR IDF-TB404 IDF15E IDF-TR IDF-TR IDF-TR IDF22E-30 IDF-TR1700-6, IDF-TB IDF-TR IDF22E-20 IDF-TR , IDF-TR IDF37E-30 IDF-TR1700-6, IDF-TB IDF-TR IDF37E IDF-TR , IDF-TR IDF55E-30 IDF-TR IDF-TR IDF-TB IDF-TR IDF75E-30 IDF-TR IDF-TR Part no. pplicable air dryer pplicable transformer B D E F G Unit weight Reference weight [kg] (including air dryer and transformer) [kg] IDF-TR IDF-TR IDU8E IDF-TR IDF-TR IDU-TB IDF-TR IDF-TR IDU11E IDF-TR IDF-TR IDF-TR IDF-TR IDU-TB408 IDU15E IDF-TR IDF-TR IDF-TR IDU-TB410 IDU22E IDF-TR1700-6, IDF-TR IDU-TB411 IDU37E IDF-TR1700-6, Selection IDF F IDF D Optional ccessories Specific Product Precautions

40 IDF/IDU Series [Dust-protecting filter set] (20) () (20) (10) (B) (IDF-FL200, 201) (IDF-FL202 to 214) (IDU-FL210 to 218) Part no. pplicable air dryer B Weight [g] IDF-FL200 IDF1E, 2E IDF-FL201 IDF3E IDF-FL202 IDF4E IDF-FL203 IDF6E, IDU3E IDF-FL204 IDF8E, IDU4E IDF-FL205 IDF11E, IDU6E IDF-FL206 IDF15E IDF-FL207 IDF22E IDF-FL208 IDF37E IDF-FL213 IDF55E IDF-FL214 IDF75E filter set for the IDF-FL200 to 214 consists of 1 filter. Part no. pplicable air dryer B IDF-FL190D IDF190D IDF-FL240D IDF240D filter set for the IDF-FL190D to 240D consists of 4 filters. Part no. pplicable air dryer B Weight [g] IDU-FL210 IDU8E IDU-FL211 IDU11E IDU-FL212 IDU15E IDU-FL215 IDU22E IDU-FL216 IDU37E IDU-FL217 IDU55E IDU-FL218 IDU75E filter set for the IDU-FL210 to 212, 215 to 218 consists of 2 filters. 39

41 Optional ccessories IDF/IDU Series [Bypass piping set] IDF1E to 3E ompressed air inlet ompressed air outlet () (B) (D) (E) IDF4E to 15E1 IDU3E to 6E (D) (E) ompressed air inlet ompressed air outlet (B) () Selection () () pplicable Part no. B D E Weight air dryer Rc [kg] IDF-BP300 IDF1E IDF-BP301 IDF2E 3/ IDF-BP302 IDF3E IDF22E, 37E IDU22E to 75E ompressed air outlet (D) (B) () ompressed air inlet pplicable Part no. B D Weight air dryer Rc [kg] I IDF-BP317 IDF22E D F IDF-BP318 IDF37E 1 1/ IDU-BP336 IDU22E I IDU-BP337 IDU37E 1 1/ D U IDU55E IDU-BP IDU75E 1918 () Part no. pplicable Weight B D E air dryer Rc [kg] IDF-BP303 IDF4E 1/ I IDF6E D IDF-BP304 IDF8E 3/4 187 F IDF11E IDF-BP316 IDF15E I IDU-BP305 IDU3E 3/ D IDU-BP306 IDU4E 1/ U IDU-BP307 IDU6E 3/ IDF55E, 75E (110) (250) Part no. IDF-BP325 ompressed air outlet pplicable air dryer IDF55E Rc (519) (455) ompressed air inlet IDF75E 1291 (128) () Weight [kg] IDF F IDF D Optional ccessories Specific Product Precautions

42 IDF/IDU Series [Bypass piping set] IDU8E to 15E1 (D) (E) ompressed air inlet (F) (B) () ompressed air outlet () Part no. pplicable B D E Weight air dryer Rc [kg] IDU-BP320 IDU8E 3/4 31 IDU11E IDU-BP322 IDU15E [Foundation bolt set] Mounting hole dia.: ø10.5 Part no. IDF-B500 IDF-B501 pplicable air dryer IDF4E to 75E IDU3E to 15E1 IDU22E to 75E IDF100 to 150F Nominal thread size M10 Material Stainless steel Number of 1 set [Piping adapter] E (Width across flats) D Female thread B side Male thread side Part no. Thread type and port size Number pplicable air dryer D E Material Male thread side Female thread B side of 1 set IDF-P601 R1/2 NPT1/2 IDF4E IDU4E IDF-P603 R3/4 NPT3/4 IDF6E to 11E IDU6E to 11E IDF-P604 NPT1 Rc1 IDF22E, IDU22E IDF-P605 R1 NPT1 IDF15E1, IDU15E1 Brass 2 IDF-P606 NPT1 1/2 Rc1 1/2 IDF37E, IDU37E IDF-P607 NPT2 Rc2 IDF55E, 75E, IDU55E, 75E IDF100 to 150F IDF-P609 R3/8 NPT3/8 IDF1E to 3E IDU3E

43 Optional ccessories IDF/IDU Series [Mounting base adapter] IDF22E, 37E ompressed air inlet (134) () (405) ompressed air outlet (93) (290) Selection (D) (602) (101) B (410) (71) ompressed air outlet 4 x ø13 Part no. pplicable air dryer R B D E F G [onversion piping set] IDF6E ompressed air inlet (109) E F G [onversion piping set] ompressed air outlet IDF15E1 ompressed air inlet (134) (405) (105) (722) Single unit weight [kg] Reference weight (including air dryer) [kg] IDF-S0189 IDF22E IDF-S0147 IDF37E 1 1/ IDF F IDF D 4 x ø13 Port Size (587) Part no. pplicable air dryer Rc Weight [kg] IDF-S0186 IDF6E 1/2 3.5 IDF8E, 11E (331) (61) ompressed air inlet 4 x ø13 Port Size (B) ompressed air outlet () (748) Part no. pplicable air dryer Rc Weight [kg] IDF-S0188 IDF15E () 4 x ø Part no. pplicable air dryer Rc B Weight [kg] IDF-S0203 IDF8E 3/ IDF-S0187 IDF11E 3/ (90) (617) 42 Optional ccessories Specific Product Precautions

44 IDF/IDU Series [onversion bypass piping set] IDF6E to 15E1 (B) ompressed air inlet (F) (G) ompressed air outlet () 4 x ø13 E D (J) H I Part no. pplicable air dryer Rc B D E F G H I J IDF-S0183 IDF6E 1/ IDF-S0202 IDF8E 3/ IDF-S0184 IDF11E 3/ IDF-S0185 IDF15E Weight [kg] 43

45 IDF/IDU Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for Safety Instructions. For ir Preparation Equipment Precautions, refer to the Handling Precautions for SM Products and the Operation Manual on the SM website, aution Installation void locations where the air dryer will be in direct contact with wind and rain. (void locations where relative humidity is 85% or more.) void exposure to direct sunlight. void locations that contain much dust, corrosive gases, or flammable gases. Failure due to corrosion is not covered under warranty. However, when the risk of corrosion is high, select the Option (anti-corrosive treatment for copper tube). void locations of poor ventilation and high temperature. void locations where the air dryer is too close to a wall, etc. Leave a sufficient space between the air dryer and the wall according to the Maintenance Space in the Operation Manual. void locations where the air dryer could draw in high temperature air discharged from an air compressor or other dryer. onfirm that the exhaust air does not flow into the neighboring equipment. void locations where vibrations occur. void possible locations where the drain can freeze. void locations with an ambient temperature 40 or higher (IDF100F to 150F: 45 or higher). void installation on machines for transporting, such as vehicles, ships, etc. void locations where rapid pressure fluctuation or flow speed change is generated. aution Drain Tube polyurethane tube is attached as a drain tube for the IDF1E to 150F, IDU3E to 75E. Use this tube to discharge drainage to a drain tank, etc. Do not use the drain tube in an upward. Do not bend or crush the drain tube. (Otherwise, the operation of an auto drain will stop and drainage will discharge through the air outlet.) If it is unavoidable that the tube goes upward, make sure it only goes as far as the position of the auto drain outlet. aution Power Supply <100 V> Insert the power supply plug to an exclusive 100 V power outlet. Install an earth leakage breaker*1 suitable to each model for the power supply. Maintain voltage range within ±10% of the rated voltage. Be sure to ground the power supply prior to use. Multiple-branch wiring is dangerous since it causes overheating. Do not extend the power cable by using a table tap, etc. voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 m and a rated current of 10. <200 V> onnect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply. Maintain voltage range within ±10% of the rated voltage. *2 Select an earth leakage breaker with a sensitivity of leak current of 30 m. s regards rated current, refer to pplicable Earth Leakage Breaker apacity on pages 8, 12, 15, 16, 20, 23 and 26. When using with other voltages than specified for a standard product, use a separately installed power transformer. (page 34) Selection Optional ccessories IDF F IDF D 44 Specific Product Precautions

46 IDF/IDU Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for Safety Instructions. For ir Preparation Equipment Precautions, refer to the Handling Precautions for SM Products and the Operation Manual on the SM website, aution Be careful to avoid an error in connecting the air piping at the compressed air inlet (IN) and outlet (OUT). Install bypass piping since it is needed for maintenance. Use the bypass piping set on pages 40 and 41. IDF1E to 3E ompressed air inlet ompressed air outlet Valve closed Valve open ir Piping When tightening the inlet/outlet air piping, firmly hold the hexagonal parts of the port on the air dryer side or piping with a wrench or adjustable angle wrench. Variations in operating conditions may cause condensation to form on the surface of the outlet piping. pply thermal insulation around the piping to prevent condensation from forming. onfirm that vibrations resulting from the compressor are not transmitted through the air piping to the air dryer. Do not allow the weight of the piping to lie directly on the air dryer. If a metallic flexible tubing is used for the inlet/outlet air piping, abnormal noise might be generated in the piping. In that case, please change it to the steel tubing. IDF4E to 15E1 IDU3E to 15E1 IDF22E, 37E IDU22E to 75E IDF55E, 75E ompressed air inlet ompressed air outlet Valve open ompressed air outlet Valve closed ompressed air outlet Valve closed Valve open ompressed air inlet Valve open Valve closed ompressed air inlet aution Protection ircuit When the air dryer is operated in the following cases, the protection circuit will activate, the light will turn off and the air dryer will come to stop. The compressed air temperature is too high. The compressed air flow rate is too high. The ambient temperature is too high. (40 or higher (IDF100F to 150F: 45 or higher)) The fluctuation of the power supply voltage is beyond ±10% of the rated voltage. The air dryer is drawing in high temperature air exhausted from an air compressor or other dryer. The ventilation grille is obstructed by a wall or clogged with dust. Transportation and Installation Warning Be sure to follow the instructions below for transporting the product. The product is filled with refrigerant. Transport it (by land, sea or air) in accordance with laws and regulations specified. When carrying the product, be careful not to let it drop or fall over. Lift it by using a forklift or rope and lifting hook. The lifting angle should be 45 or more. Note) The lifting hooks are installed on the IDF100F to 150F. Do not lift the product by holding the panel, fittings or piping. Never lay the product down for transportation. This may lead to damage to the product. The product is heavy and has potential dangers in transportation. Be sure to follow the instructions above. Be sure to use a forklift or lifting hook for transporting the product. Lifting position 45 or more 45 or more 45

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

Refrigerated Air Dryer Large Size Series

Refrigerated Air Dryer Large Size Series Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

Refrigerated Air Dryer Large Size Series

Refrigerated Air Dryer Large Size Series ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Refrigerated ir Dryer Large Size Series IDF25F/50F are added! New Model IDF00F- IDF00F--W

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Large Size Series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 Inlet air temperature 60 Energy

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

% by up ctoond re-heater and

% by up ctoond re-heater and Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,

More information

With air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed.

With air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed. Thermo-dryer With air temperature adjustment function New RoHS Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed air with the same conditions and quality

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet

More information

CKD refrigerating type dryer

CKD refrigerating type dryer CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type

More information

Prevents condensation

Prevents condensation Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting

More information

using heat exhausted by refrigerating circuit.

using heat exhausted by refrigerating circuit. Circulating Fluid Temperature Controller Thermo-chiller No heater required, circulating fluid is heated using heat exhausted by refrigerating circuit. Circulating fluid temperature [ F] Cooling capacity

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

Moisture Control Tube

Moisture Control Tube Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) -80 www.cmafh.com Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air

More information

White paper Compressed air drying

White paper Compressed air drying White paper Compressed air drying White paper : Compressed air drying Table of content Introduction 4 Where does the water come from? 5 How to remove the water? 6 Drying methods 7 Refrigerant dryers 8

More information

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions Circulating Fluid Temperature Controller Thermo-chiller Lightweight/Compact Temperature stability Standard Type ±.1 C New HRS5 New HRS6 (UL Standards) RoHS HRS12/18/24 New HRS3 Same width for all models:

More information

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series 10 3000 SCFM REFRIGERATED COMPRESSED AIR DRYERS CRN Series Durability Delivered Champion CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor.

More information

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series NON-CYCLING REFRIGERATED AIR DRYERS RNC Series Durability Delivered Gardner Denver RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent. anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................

More information

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Compressed air preparation Compressed air storage Moisture management. Catalog #1 Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.

More information

Operation Manual Installation Operation

Operation Manual Installation Operation HRX-OM-Q026 1 st edition: December 2012 Rev. L: Nov.2017 Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH100-A -20- HRSH150-A -20- HRSH200-A -20- HRSH250-A -20- HRSH300-A

More information

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S Polar Air Dryer R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S PDRCF1150029 PDRCF4602000 Instructions Manual TABLE OF CONTENTS 1. Important safety notes - Please read... 1 1.1. Transportation...

More information

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W New Circulating Fluid Temperature Controller Thermo-chiller (UL Standards) Compact Type RoHS HRG(C)5 (Existing model) Compact Space-saving HRS5 976 Ve 615 n tio 592 5 377 377 (mm) (mm) Lightweight 4 kg

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

Drain Separator for Vacuum

Drain Separator for Vacuum Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port

More information

Water Circulator (Chiller) & Cold Trap

Water Circulator (Chiller) & Cold Trap Yamato Scientific America Innovating Science for Over 125 Years Water Circulator (Chiller) & Cold Trap Contents Water Circulator (Chiller) Cold Trap CA Series Page Page 91 93 9 Water Circulator (Chiller)

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

High Performance Air to Water Heat Pump

High Performance Air to Water Heat Pump High Performance ir to Water Pump ir to Water Pump Hz 10HM01E0 ir to Water Pump Mitsubishi Heavy Industries has integration of high technology in a variety of areas and provides comprehensive solutions

More information

76% reduced. 25% reduced. by up to 76% Saves energy. Refrigerated Air Dryer. New. Series IDF100FS/125FS/150FS

76% reduced. 25% reduced. by up to 76% Saves energy. Refrigerated Air Dryer. New. Series IDF100FS/125FS/150FS Refrigerated Air Dryer Double energy saving function series Second re-heater Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant New RoHS Saves energy by

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller ir ooled Scroll hiller Midea chillers use V shape heat exchanger and single unit s capacity from 30kW to 250kW.They are divided to PS, PS-L,PS-HM and PS-HML series according to their operation ambient

More information

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual Instructions Manual 1. Important safety notes - Please read... 1 1.1. Transportation... 1 1.2 Positioning... 1 1.3 Installation... 1 1.4 Before operating... 1 1.5 Maintenance by an engineer... 1 1.6 Maintenance

More information

Condensate Drain Valves

Condensate Drain Valves Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

OTC, OTM and OTI Series Options

OTC, OTM and OTI Series Options OTC, OTM and OTI Series Options Audible Alarm w/silence (AA1)...2 Anti Drain-back Valve (AD1 or AD2)...2 Alarm Beacon (AV1)...2 Auto Water Make-up (AWM)...2 Balancing Valves...2 Uncontrolled DI Loop (D01)...2

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

CRN Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Refrigerated Compressed Air Dryers

CRN Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Refrigerated Compressed Air Dryers CRN Series Refrigerated Compressed Air Dryers 10 3000 SCFM ISO Qulaity Class Performance Integral Filtration Stainless Steel Brazed Plate Heat Exchangers 2 Durability Delivered CRN Series Refrigerated

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Makes cooling water easily available, anytime, anywhere. Worldwide in voltage: Single phase 200 to 230 VAC, 50/60 Hz Compliant with standards:,

More information

High Performance Air to Water Heat Pump

High Performance Air to Water Heat Pump R410 20 High Performance ir to Water Pump ir to Water Pump Hz HM01E ir to Water Pump Mitsubishi Heavy Industries has integration of high technology in a variety of areas and provides comprehensive solutions

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Kawasaki centrifugal chiller using water as a refrigerant Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Introduction of MiZTURBO 2. Study of CO 2 emissions

More information

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES

More information

CNC Series Refrigerated Air Dryer CFM

CNC Series Refrigerated Air Dryer CFM CNC Series Refrigerated Air Dryer 10 3000 CFM NEW Engineered to Save CNC Value CompAir leads the way in providing value to our customers We looked beyond the typical refrigerated air dryer and designed

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers Refrigerated Air Dryers Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. 107 W. Main St. Worthington, Pennsylvania 16262 Phone: (724) 297 3416

More information

Refrigeration dryers DW 2-504

Refrigeration dryers DW 2-504 DW Refrigeration dryers DW 2-504 Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has 145 years of industrial experience. It is our ambition to offer compressed

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Refrigerated Thermo-cooler

Refrigerated Thermo-cooler Circulating Fluid Temperature Controller Refrigerated Thermo-cooler Series Makes cooling water easily available, anytime, anywhere. Cooling capacity (60 Hz): 9.5 kw/14.5 kw (Air-cooled refrigeration) 11.0

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

NIBE SPLIT ACVM 270 Air/water heat pump

NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 Air/water heat pump NIBE SPLIT ACVM 270 system with complete indoor module NIBE SPLIT ACVM 270 is a complete modern heat pump system that offers effective technical energy saving and

More information

Refrigerated Compressed Air Dryer

Refrigerated Compressed Air Dryer Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Refrigerated Compressed Air Dryers

Refrigerated Compressed Air Dryers 10 to 500 SCFM 17 to 850 M 3 /H Refrigerated Compressed Air Dryers HG, HGE & HGN VALUE SERIES Reliable Operation... Customers around the world have relied on Deltech for great value in air treatment solutions.

More information

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

Prevents condensation

Prevents condensation Moisture Control Tube Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor Linear shape Suitable for applications where cylinders

More information

Large energy saving by triple control!

Large energy saving by triple control! Circulating Fluid Temperature Controller Thermo-chiller Basic Type (Only 23 VAC type) RoHS Large energy saving by triple control!.8 kw.54 kw Power consumption 33% Energy saving * Under the conditions shown

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

Instruction Manual. Refrigerated Air Dryer

Instruction Manual. Refrigerated Air Dryer January 2008 Edition Carefully read this manual before attempting to operate or perform maintenance on this equipment. Instruction Manual Of Refrigerated Air Dryer Hangzhou Kelin Aier Qiyuan Equipment

More information

High Performance Air to Water Heat Pump

High Performance Air to Water Heat Pump R410 High Performance ir to Water Pump ir to Water Pump Hz 11HM01E0 ir to Water Pump Mitsubishi Heavy Industries has integration of high technology in a variety of areas and provides comprehensive solutions

More information

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr) PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm

More information

Lightweight and Compact

Lightweight and Compact Circulating Fluid Temperature Controller Thermo-chiller Standard Type (Only 400 VAC type) Lightweight and Compact RoHS Cooling capacity 9 kw Weight 136 kg Temperature stability ±0.5 C (when a load is stable)

More information

Printed 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS

Printed 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS Printed 2000, replaces all previous editions Kyl M (98) PK.523 PK.5231 PK.5232 OOLIN UNITS OR LIMT ONTROL, OMMRIL RRIRTION N INUSTRIL PPLITIONS Swedish cooling units. Mini, Mid The rigadon range of commercial

More information

SYNRAD Technical Bulletin # 0015d

SYNRAD Technical Bulletin # 0015d Page 1 of 6 SYNRAD Technical Bulletin # 0015d Technical Issue: Purge Gas Conditioning for f201/f400, i401, & p100/p250 Lasers Date: 30 July 2014 Description: This Technical Bulletin describes how to prevent

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

Pressure Enthalpy Charts

Pressure Enthalpy Charts Pressure Enthalpy Charts What is a p-h Diagram? A p-h diagram is a diagram with a vertical axis of absolute pressure and a horizontal axis of specific enthalpy. "Enthalpy is the amount of energy in a substance

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Section 10 Bulletin A -7 Pneumatech is proud to offer this range of reliable and innovative refrigerated air dryers. These dryers are a cost effective

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information