EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS

Size: px
Start display at page:

Download "EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS"

Transcription

1 ELECTRIC DUCT HEATERS EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS USER MANUAL Subject to technical modification EKA_P0093_AZ_0001

2 SAFETY INSTRUCTIONS AND PRECAUTIONS 3 WARNING! SAFETY REQUIREMENTS 3 TRANSPORTING AND STORING 3 RECEIVING AND HANDLING 3 SERVICE 3 QUALITY 3 INGRESS PROTECTION (IP) RATING 3 CIRCULAR DUCT HEATER TYPES 4 SPECIFICATION 4 INSTALATION 4 ELECTRICAL CONNECTION 5 WIRING DIAGRAMS 6 HEATERS DESCRIPTION & STRUCTURE 11 DOUBLE OVERHEAT PROTECTION 11 DUCT CONNECTION 11 CONTROL 11 EXTERNAL CONTROL OF THREE-PHASE HEAT- ERS 11 EXTERNAL CONTROL OF ONE-PHASE & TWO- PHASE HEATERS 11 HEATERS WITH BUILT-IN CONTROL 11 AIR VELOCITY 11 CIRCULAR DUCT HEATER TYPES 11 APPENDIX A. CIRCULAR DUCT HEATERS POWER & DIMENSIONS 12 TROUBLESHOOTING 13 WARRANTY 14 WARRANTY CLAIM FORM 14 2

3 The electrical heater s model and serial number is located on the label of the product. Improper use of this heater can result in serious bodily injury due to hazards of fire and explosion, burn and electrical shock. Use only with electrical voltage and frequency specified on model label. Do not perform any service with heater plugged in. Serious injury or death may occur if personnel come in contact with high voltage lead. Parts of the heater become very hot when operating and immediately after operating. Severe burns may occur if the heater is not allowed to cool down properly before servicing. All products are packed by producer for normal transporting conditions. For unloading and storing use proper lifter to prevent product damage and employees injuries. Do not lift product by power supply cable, connection box. Avoid impacts and impact loads. Until final installation store products in dry place with humidity not more 70% (20 C), average ambient temperature must be 5-40 C. Storing place must be covered from water and dirt. Avoid long term storing. It is not recommended to store products more then 1 (one) year. Inspect heater for any possible shipping damage. Inspect heater element wire for any deformation that could cause a short circuit or ground. Make sure that casing of the heater is not damaged. No special service is required for electrical heaters, only to check electrical connection not less then 1 time per year. We care about quality. 100% of heaters are tested before shipment. First Numeral Protection against contact and ingress of foreign bodies: most wires, screws, etc. Second Numeral Protection against water: water splashing against the enclosure from any direction shall have no harmful effect. Heaters type EKA, EKA NI, NIS protection rating is IP44. Heaters type EKA NV, EKA NV PTC/PS, EKA NV PH protection rating is IP30. Thank you for your purchase of this product. This manual describes how to use and install the supplied product. Be sure that you have read and understood its contents before using the heater. 3

4 To ensure long service time and quality heating we use heating elements from stainless steel. In one-phase (1x230 V) heaters EKA are installed one-phase (1x230 V) heating elements of following power: 0.3 kw, 0.6 kw, 1.0 kw, 1.2 kw. Heater voltage 1x230V Heater power 0.3 kw 0.6kW 0.9kW 1.2kW 1.5kW 1.8kW 2.0kW 2.4kW Number of heating elements 1x0.3 2x0.3 3x0.3 4x0.3 5x0.3 6x0.3 2x1.0 4x0.6 Heater voltage 2x400V 3x400V Heater power 3.0 kw 5.0kW 6.0kW 6.0kW 9.0kW 12.0kW 15.0kW Number of heating elements 3x1.0 5x1.0 6x x1 6x1.5 6x1.5+3x1.0 6x1.5+6x1.0 In two phase (2x400 V) and three-phase (3x400 V) heaters are installed three-phase (3x400 V) heating elements of following power: 1.0 kw and 1.5 kw. EKA NV f PTC PS Heater with installed pressure PTC/PS type can be marked also as NV PH if temperature setpoint of the heater -20 C to -5 C Heater with installed air flow Number of phases. Power of heater kw Heater diameter Heater type. Type NV - you can set temperature of heater with potentiometer installed on heaters casing. Type NI - you can set temperature from distance with wired remote potentiometer TR5K Type NIS heater control from distance with 0 10 V signal. Circular duct heater Heater can be installed in any position (see picture below) except electrical connection box downward. If heater is installed in such way that can be accidental contact with heating elements, protective grill must be installed. Air flow through heater must be not less 1,5 m/s. Heaters can not be installed in explosive and aggressive substances atmosphere. Heaters can be used only for clean air heating. Heaters intended for inside installation. Heaters installation position: Installation example EKA NV F V Temperature set knob Room EKA NIS Duct TJ D 3xD 4

5 Installation example EKA NI Room F V EKA NIS Duct TJ D 3xD Temperature set knob TR5K - controller Installation example EKA NIS External 0-10VDC signal F V Room EKA NIS D Installation example EKA NV PTC/PS AHU* TK-K10K RP1 LED1 LED2 RESET PS EKA NIS F 3xD EKA NV...PTC/PS D Casing and air duct before heater should be insulated with rock wool 10 cm (R~2,4 m²k/w). It is recommended to install air filter before the heater. *AHU air handling unit with heat recovery. F supply air filter. Depending on the installation location of the heater in the duct relative to the engine (before or behind the engine), the pressure hose therefore has to be attached to a + or the - tube. If heater is installed behind engine - tube inside, + tube before the engine. 3xD we recommend install duct temperature in minimum distance multiplied by the heater s diameter. For example: heater EKA diameter 315 mm, s installation length will be: 315x3=945 mm. INDICATION of LED lamps on EKA NV PTC/PS casing 1. LED1 Flashing 1 time per 3 seconds EKR KN warming up (~30 s) Flashing 1 time within second EKR KN ready, Lights up fault of duct temperature T J-K10K, or air flow PTC fault. 2. LED2 Lights up load is on (heating). 1. Electrical connection can be made only by qualified electrician according legal international and national electrical installation standards. 2. Power supply source must conform with data on heater label. 3. Power supply cable must be selected corresponding to heater electrical data. 4. Automatic circuit breaker with at least 3 mm contact gap must be installed. Automatic circuit breaker must and relay be selected corresponding to 5

6 technical data table. 5. Heater must be grounded. 6. For heaters install duct temperature and connect as in wiring diagram. EKA 1X230V EKA 2X400V EKA 3X400V 6

7 EKA NV 1x230V TJK10K duct temperature EKA NV 2x400V TJK10K duct temperature EKA NV 3x400V TJK10K duct temperature 7

8 EKA NI 1x230V TJK10K duct temperature TR5K external potentiometer EKA NI 2x400V TJK10K duct temperature TR5K external potentiometer EKA NI 3x400V TJK10K duct temperature TR5K external potentiometer 8

9 EKA NIS 1x230V EKA NIS 2x400V EKA NIS 3x400V 9

10 EKA NV PTC/PS, NV PH 1x230V TJK10K temperature PS - pressure PTC air flow RP1 - potentiometer EKA NV PTC/PS, NV PH 2X400V TJK10K temperature PS - pressure PTC air flow RP1 - potentiometer EKA NV PTC/PS 3X400V TJK10K temperature PS - pressure PTC air flow RP1 - potentiometer 10

11 Duct heaters are designed to heat clean air in ventilation systems and to preheat air handling units. Corrosion resistant casing with excellent thermal reflectivity is made from AluZinc. Duct connection is with rolled rubber seals, duct heater elements are made from stainless steel. To ensure safety in duct heaters are installed 2 protection thermostats and screw terminals for easy connection. Heaters casings are produced from AluZinc coated steel and heating elements from stainless steel AISI 304. AluZinc casing was selected because for its properties: Good corrosion resistance at high temperatures (up to 315 C) Excellent thermal reflectivity Good abrasion resistance because of its surface hardness Durability: under normal conditions the AZ 150 coating grade will protect the steel substrate from corrosion for a minimum period of 15 years. To ensure security in case of fire in all electric air heaters 2 heat protection thermostats are installed: First overheat protection automatically activates if temperature reaches 50 C, then protection disconnects heating elements, until it has cooled. When the temperature falls to the working temperature, heater automatically switches on. Second overheat protection automatically activates if temperature reaches 100 C, then protection disconnects heating elements, until it has cooled. In this case need to figure the cause of the overheating of the heater. Heater needs to be reset manually with the pushbutton on the heaters casing. For easy duct connection heaters casing is with rolled rubber seals. Standard circular duct heaters type EKA has no internal controller, in this case can be used external heating controllers EKR 15.1, EKR 15.1P, EKR 30, EKR 30P and temperature TJK 10 K. Controllers and are not included in the package of product. Model Controlled load [kw] Extra load control* Full load Relay output Voltage output EKR Up to 12 kw 27 kw 1x5A/230V 3x230/3x400 EKR15.1P 15 Up to 225 kw 240 kw 4x5A/230V 3x230/3x400 EKR30 30 Up to 42 kw 42 kw 1x5A/230V 3x230/3x400 EKR30P 30 Up to 420 kw 450 kw 4x5A/230V 3x230/3x400 * Extra load control with contactor For one-phase and two-phase heaters control we recommend to use proportional controller EKR6.1 and temperature TJK10K. Controller and are not included in the package of product. Model Controlled load [kw] Maximum controlled current [A] Voltage output EKR6.1 6,4 kw/400v 2x400V 16 A 3.2 kw/230v 1x230V Electric duct heaters with built-in control has installed internal controller EKR-KN which works by algorithm impulse/pause..., that enables fine temperature control. Regulator controls load by triacs without moving parts, which causes no-noise commutation. Following models of heaters are with internals controllers, and there are differences between them: Type NV - you can set temperature of heater with potentiometer installed on heaters casing. Type NI - you can set temperature from distance with wired remote potentiometer TR5K Type NIS heater control from distance with 0 10V signal. Type PTC heater with installed air flow. Type PS heater with installed pressure Type NV PTC/PS or NV PH heater with installed air flow and pressure. Heaters with built-in controls comes with temperature duct in the package of the product (except type EKA NIS). The duct heaters are designed for a minimum air velocity of 1,5 m/s. If the air flow is lower than 1.5 m/s it can often be activated overheat protection. Model Control Control type EKA External controller EKR External control EKA NV Built-in controller EKR-KN Control on heaters casing, default temperature setpoint 0 C C 11

12 EKA NV PTC/PS, NV PH EKA NI Built-in controller EKR-KN Built-in controller EKR-KN EKA NIS Built-in controller EKR-KN 0-10 V control Control on heaters casing, default temperature setpoint -10 C C. Air flow and pressure are installed inside the heater. Difference between heaters is EKA NV PTC/PS and EKA NV PH, that EKA NV PH temperature setpoint is -20 C iki -5 C. Remote control with wired potentiometer, default temperature setpoint 0 C C In heaters type NV PTC/PS are installed controllers with default temperature setpoint -10 C C, on your needs we can install controllers with different temperature setpoints: -40 C till -10 C 0 C till +30 C -5 C till 0 C -20 C till -5 C -10 C till 0 C - Please inform about needed temperature setpoint before production, othervise heater will be produced with factory default setpoint. All circular duct heaters EKA regardless of the type can be produced in following dimensions and power: Type Diameter Min. airflow [m 3 /h] Voltage [V/50Hz] Power [kw] EKA (NV, NV PTC/PS, NI, NIS) x , 0.6, 0.9, 1.2 EKA (NV, NV PTC/PS, NI, NIS) x , 0.6, 0.9, 1.2, 1.8, 2.4 EKA (NV, NV PTC/PS, NI, NIS) EKA (NV, NV PTC/PS, NI, NIS) EKA (NV, NV PTC/PS, NI, NIS) EKA (NV, NV PTC/PS, NI, NIS) EKA (NV, NV PTC/PS, NI, NIS) EKA (NV, NV PTC/PS, NI, NIS) x , 0.6, 0.9, 1.2, 1.8, 2.4 2x , 5.0, 6.0 3x x , 1.2, 1.8, 2.4, 3.0 2x , 5.0, 6.0 3x x , 2.0, 2.4, 3.0 2x , 5.0, 6.0 3x , 9.0, x , 2.0, 2.4, 3.0 2x , 5.0, 6.0 3x , 9.0, x , 5.0, 6.0 2x , 5.0, 6.0 3x , 9.0, 12.0, 15.0, x , 5.0, 6.0 3x , 9.0, 12.0, 15.0, 18.0, and 24.0 kw heaters are produced on customers request. Production time can be longer as usually. 270 mm dimension for heaters up to 12 kw 400 mm dimension for 12 kw heaters 520 mm dimension for 15 kw heaters 370 mm dimension for heaters up to 12 kw 505 mm dimension for 12 kw heaters 630 mm dimension for 15 kw heaters 12

13 Standard heaters EKA No heat from heater Automatic circuit breaker switching off Protection thermostat cut off 1. Manual reset thermostat is cut off. In this case need to figure the cause of the overheating of the heater. Eliminate overheating cause, press RESET button on heaters cover. 2. No power supply to heater check all external electrical connection components (relays, switches, controllers) 1. Check circuit breakers data, it must correspond to heaters electrical data. 2. Check isolation of connection cables, wires, check is heater grounded. 3. Check power supply source data, it must correspond to heaters electrical data. 1. Low air flow speed through heater. Check filters, fans, ducts of system. Heaters with built-in controls EKA NV, NI, NIS No heating from heater Heater gives full output, not by setpoint Automatic circuit breaker switching off Protection thermostat cut off 1. Manual reset thermostat is cut off. In this case need to figure the cause of the overheating of the heater. Eliminate overheating cause, press RESET button on heaters cover. 2. No power supply to heater check all external electrical connection components (relays, switches, controllers). 3. Temperature fault. Check resistance, it must be 10 kω at 25 C. 4. External setpoint device fault. Check device potentiometer resistance, it must be 5 kω. 5. PCB fault. Change PCB. 1. Temperature fault. Check resistance, it must be 10 kω at 25 C. 2. External setpoint device fault. Check device resistance, it must be 5 kω. 3. Triacs fault. Check triacs conductance. 4. PCB fault. Change PCB. 1. Check circuit breakers data, it must correspond to heaters electrical data. 2. Check isolation of connection cables, wires, check is heater grounded. 3. Check power supply source data, it must correspond to heaters electrical data. 1. Low air flow speed through heater. Check filters, fans, ducts of system. Heaters with built-in controls EKA NV PTC/PS No heating from heater Heater gives full output, not by setpoint Automatic circuit breaker switching off Protection thermostat cut off 1. Manual reset thermostat is cut off. In this case need to figure the cause of the overheating of the heater. Eliminate overheating cause, press RESET button on heaters cover. 2. No power supply to heater check all external electrical connection components (relays, switches). 3. Temperature fault. Check resistance, it must be 10 kω at 25 C. 4. Pressure switch fault. Check if pressure in system is set correctly (check the pressure when air flow is not less then 1,5 m/s). 5. PCB fault. Change PCB. 1. Temperature fault. Check resistance, it must be 10 kω at 25 C. 2. Air flow fault. Check resistance. It must be 22 Ω between X15..X16 and 10 Ω between X15..X18. Sensor must be clear. 3. Triacs fault. Check triacs conductance. 4. PCB fault. Change PCB. 1. Check circuit breakers data, it must correspond to heaters electrical data. 2. Check isolation of connection cables, wires, check is heater grounded. 3. Check power supply source data, it must correspond to heaters electrical data. 1. Low air flow speed through heater. Check filters, fans, ducts of system. 2. Pressure switch fault. Check if pressure in system is set correctly (check the pressure when air flow is not less then 1,5 m/s). 13

14 1. Manufacture declare 2 years warranty term from the date of manufacturer s invoice. Warranty is applied in case if all requirements of transporting, storing, installation and electrical connection are fulfilled. 2. In case of damaged or faulty product during warranty term customer must inform producer in 5 days and deliver product to manufacture as soon as possible at customer s costs. In other case warranty is not valid. 3. Manufacture is not responsible for damages which occur during transportation or installation. - Warranty Claim Form has to be COMPLETELY filled out and sent to the producer by or fax. - Product or product part serial number and production date must be indicated. - All defective products or product parts should be returned to factory with the copy of this form. - If the above mentioned point No. 3 can not be fulfilled and there are serious reasons for that, all possible information (photos, descriptions and etc.) has to be sent with this form. Photos must be taken in such a way that product or product part label and possible defect part is clearly visible and identified. - Warranty claim would not be accepted if product or product part is mechanically damaged or there were made any modifications to the product without written producer consent. - An invoice has to be included to obtain warranty. Date: Filled out by: Company: Address: Phone: Fax: Product or product part name: Serial number: Production date: Malfunction date: Reason why product or product part is not delivered back to the factory (if delivered, filling not needed): Product installation place and environment (mounted on a wall, standing on the floor and etc.; living room, working place, surrounding area and etc.): Operating data: Approximate number of working hours per day: Working temperature from to : Humidity : % Date of last technical inspection: Full explanation of the malfunction: Part to be filled out by producer Warranty Claim Form reception date: Received by: Defective product delivered back to the factory (yes/no): Producer decision and explanation: 14

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS ELECTRIC DUCT HEATERS EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS USER MANUAL Subject to technical modification EKS_P0082_AZ_0002 Safety instructions and precautions 3 WARNING! SAFETY REQUIREMENTS

More information

EKA / EKA NV / EKA NI / EKA NIS

EKA / EKA NV / EKA NI / EKA NIS EKA / EKA NV / EKA NI / EKA NIS Electric duct heater EKA duct heaters are designed to heat clean air in ventilation systems and to preheat air handling units. Corrosion resistant casing with excellent

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5,000W/240V WALL / CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model: PH-950NR PET OWNERS WARNING: The health of some small pets

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the

More information

User s guide RUH series Economical unit heater Replacement component list included

User s guide RUH series Economical unit heater Replacement component list included www.stelpro.com User s guide RUH series Economical unit heater Replacement component list included This unit complies with the CSA and UL standards For further information or to consult this guide on line,

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer GALAXY TM Series Automatic Hand Dryer Operating Instructions for the User & Installation Instructions for the Licensed Installer THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE GALAXY

More information

VFL, VFLPG, VTL and VRA Rectangular electric duct heaters

VFL, VFLPG, VTL and VRA Rectangular electric duct heaters VFL, VFLPG, VTL and VRA Rectangular electric duct heaters VFL, VFLPG, VTL and VRA Rectangular electric duct heaters VEAB rectangular duct heaters are available in ratings of up to 2000 kw and are used

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit USER S MANUAL Air duct heater with integrated temperature control unit or a control unit 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Main technical parameters

More information

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL CENTRIFUGAL FAN IN SCROLL CASING Helix S-Vent EN OPERATION MANUAL Helix / S-Vent www.blaubergventilatoren.de CONTENTS CONTENTS 3 Introduction 3 Use 3 Delivery set 4 Technical data 10 Safety requirements

More information

DISPOSER CONTROL CENTER

DISPOSER CONTROL CENTER DISPOSER CONTROL CENTER Installation Manual Model MS The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts

More information

USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED

USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED This unit complies with the CSA and UL standards SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM WARNING

More information

Split Portable Air Conditioner

Split Portable Air Conditioner SP-IOM-1 Please read and save this manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

AXIAL FANS USER S MANUAL

AXIAL FANS USER S MANUAL AXIAL FANS USER S MANUAL WARNING! Disconnect the fan from power supply prior to any connection, servicing and repair operations. Only duly qualified electricians with valid electrical permit for electric

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3 Installation Instructions...

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

Installation and operation manual

Installation and operation manual Installation and operation manual - + BRC1HHDAW BRC1HHDAS BRC1HHDAK English Table of contents Table of contents 1 General safety precautions 2 1.1 For the user... 2 1.2 For the installer... 2 2 About this

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand

More information

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING USER S MANUAL VCU/ Series CENTRIFUGAL FAN IN SCROLL CASING 2 CONTENTS Introduction Use Delivery set Designation key Technical data Safety requirements Design and operating logic Mounting and set-up Connection

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

Operating Manual MS220KA and MSR220KA

Operating Manual MS220KA and MSR220KA Temperature Relays and MINIKA, Mains Monitoring, Digital Panel meters MINIPAN, Switching Relays and Controls Operating Manual MS220KA and MSR220KA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 10,000W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model No.: DR-910F 10,000W 240V 60Hz 1 TABLE OF CONTENTS Important Instructions.3 Installing Instructions.

More information

Quest Power Electric Heat EHS 62 Pro

Quest Power Electric Heat EHS 62 Pro Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection

More information

Zehnder ComfoInline Heater

Zehnder ComfoInline Heater Zehnder ComfoInline Heater Specifications and Installation Guidelines This unit complies With CSA and UL SDHR5-1.5K120V1P-CIRO17-OTDD-OEMZ standards SDHR6-2.5K220V1P-CIRO17-OTDD-OEMZ SDHR7-3.5K220V1P-CIRO17-OTDD-OEMZ

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 7,500W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL Model: DR-975 7500W 240V 60Hz IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions. 3-4 Installation Instructions...

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR HRV H 00 ERV H 00 HRV H 300 ERV H 300 EN OPERATION MANUAL HRV /ERV H 00(300) www.blaubergventilatoren.de CONTENTS Application... Delivery set...3 Unit designation key...3 Basic

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS Nomenclature: D F I 0 0 H : Open coil element T: Tubular element F: Finned tubular element I: Slip in type F: Flange type 0: No screen left of the heater 1: Screen left of the heater 0: No screen right

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

Quest Power Electric Heat EHS 31 Pro

Quest Power Electric Heat EHS 31 Pro Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed

More information

Installer manual AG-WL10

Installer manual AG-WL10 LEK LED CLEAN TIMER OPERATION Installer manual Indoor unit air/air heat pump IHB GB 1637-1 331827 Table of Contents 1 Important information Safety information Read before starting the installation Electrical

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

Drying Ovens for Fluxes Models F100 F200 - F400

Drying Ovens for Fluxes Models F100 F200 - F400 Instruction and Maintenance Manual Drying Ovens for Fluxes Models F100 F200 - F400 SUMMARY 1. GENERAL INFORMATION....2 2. SPECIFICATIONS.....3 2.1. General Specifications...3 2.2. Oven general description...3

More information

Owner s Manual Phoenix FireBird

Owner s Manual Phoenix FireBird 4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix FireBird Installation, Operation and Service Instructions Important Instructions Read and Save These Instructions The FireBird portable, heavy duty

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems Safety Information Important Information Important: read these instructions fully before the installation of this

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Direct Draw Equipment

Direct Draw Equipment Instruction Manual Direct Draw Equipment Models HDD-1-24 (-S) HDD-2-59 (-S) HDD-3-69 (-S) HDD-3-80 (-S) HDD-4-95 (-S) hoshizakiamerica.com Issued: 08-04-2018 Revised: WARNING Only qualified service technicians

More information

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS THERMOFILM CONVECTIVE PANEL HEATER Rev C JUL13 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS 1. Important Safety Instructions 2. Specification

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VHU SERIES INSULATED HUMIDIFIED HEATED TRANSPORTATION CABINETS MODELS: VHU7 VHU18 F47668 1 IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Flow Factor ~

Flow Factor ~ Flow Factor ~ 216-765-4231 The DHC-E series is tested and certified by WQA against NSF/ANSI 372 for lead free compliance. STIEBEL ELTRON Inc. 17 West Street West Hatfield MA 01088 Tel. 413-247-3380 Fax

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Ceiling Mount Air Purification System

Ceiling Mount Air Purification System Ceiling Mount Air Purification System HA-CMP-G2-R/HA-CMP-G2-OV Owner s Manual Table of Contents HealthyAir Series 1219 Filters 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference

More information

Instruction manual. Remote control electric IR HEATER

Instruction manual. Remote control electric IR HEATER Instruction manual Remote control electric IR HEATER battery consumption rate hour temperature (preset or measured) current operation mode (e.g. comfort) current day heating activated buttons for adjustment

More information

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions GRUNDFOS INSTRUCTIONS LCD 08 Installation and operating instructions Installation and operating instructions Original installation and operating instructions CONTENTS Page. Symbols used in this document.

More information

1. GENERAL SAFETY RULES

1. GENERAL SAFETY RULES ID180 & ID290 Indirect-Fired Diesel/Oil Construction Heaters Sure Flame Products Lethbridge, Alberta, Canada Telephone: (403)328-5353 Fax: (403)328-9956 www.sureflame.ca July 12, 2006 Service and Maintenance

More information

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600 I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d Model code: BORA600 Contact Caple on 0844 8003830 or for spare parts www.4caple.co.uk 1 Y O U R A P P L I A N C E Thank you for buying your

More information

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³).

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³). USER S guide RWF series Wall fan heater Replacement component list included This unit complies with the CSA standards SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM warning Before installing and

More information

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P Salamander Heater OWNER S MANUAL Model:DR-PS11024 10KW 240V 60Hz 1P DR-PS11524 15KW 240V 60Hz 1P DR-PS31520 15KW 208V 60Hz 3P IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions...3-4

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

BriskHeat NDT Kit for Elevator Inspection

BriskHeat NDT Kit for Elevator Inspection BriskHeat NDT Kit for Elevator Inspection Instruction Manual Read and understand this material before operating or servicing these heaters. Failure to understand how to safely operate these heaters could

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE WALL/CEILING MOUNT HEATER OWNER S MANUAL Model No.: DR-966 6000W 240V 60HZ IMPORTANT INSTRUCTIONS READ & SAVE 1 TABLE OF CONTENTS Important Instructions.. 3 Specifications and Wiring Diagram 5 Parts of

More information

Index I. INSTALLATION DIAGRAM... WIRING DIAGRAMS...

Index I. INSTALLATION DIAGRAM... WIRING DIAGRAMS... Index I. INSTALLATION DIAGRAM... 4 II. III. WIRING DIAGRAMS...... 1. Wiring diagram AC 3-N-400 50/60 Hz... 2. Wiring diagram AC 3-230 50/60 Hz...... 3. Wiring diagram AC 230 50/60 Hz... 4. Series 30 electrical

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

Drying Ovens Models F3 - F6 - F9

Drying Ovens Models F3 - F6 - F9 Instruction and Maintenance Manual Drying Ovens Models F3 - F6 - F9 SUMMARY 1. GENERAL INFORMATION.....3 2. SPECIFICATIONS...4 2.1. General Specifications...4 2.2. Oven general description...4 2.3. Thermal

More information

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT 1. General The TBLZ-1-72-a optical smoke detector with built-in control unit is used for measuring

More information

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS FAN HEATER Models: DEVIL 4035 4055 4090 4115 OPERATING & MAINTENANCE INSTRUCTIONS 0705 DECLARATION of CONFORMITY We declare that this product complies with the following standards/directives: 73/23/EEC

More information

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output Operating Instructions & Parts Manual 1RKT2, 1RKT3, 1RKT4, 1RKT5, 1RKT9 and 1RKU2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the

More information

MINI ELECTRIC CONVECTION HEATER

MINI ELECTRIC CONVECTION HEATER MINI ELECTRIC CONVECTION HEATER FOR THE FOLLOWING MODELS: EE-8069 EE-8069R EE-8069W If you have any questions about the operation of your convection heater, please contact Crane Customer Care. Toll Free:

More information

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200 Series FCU1x00 Installation instructions and operating manual Sauna control system FCU1000 / FCU1200 only sauna FCU1000 additional humidity FCU1200 Doc-ID: B_M_FCU1xxx-A5_EN Version: V 1.06 certificated

More information

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual Mobile Hot Food Merchandiser Series Series: MHB Operation Manual BKI LIMITED WARRANTY Grandview Drive Simpsonville, SC 0 USA () - Toll Free: (00) - Fax: () - WHAT IS COVERED WHO IS COVERED COVERAGE PERIOD

More information

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual EN Table of Contents 1. INSTALLATION MANUAL...3 1.1. Air Handling Units Sections Connection...3

More information

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER - II CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION...

More information

CERAMIC TOWER HEATER

CERAMIC TOWER HEATER CERAMIC TOWER HEATER MODEL # EE-8079 If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care. Toll Free: 888-599-0992 Email: customer-service@crane-usa.com

More information

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN CENTRIFUGAL CEILING EXTRACT FAN Ceileo 200/250/300 Ceileo 200/250/300 Т/H/IR Ceileo 200/250/300 Light Ceileo 200/250/300 Light Т/H/IR EN USER'S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery

More information

USER S MANUAL. VKP Series INLINE FAN

USER S MANUAL. VKP Series INLINE FAN USER S MANUAL Series INLINE FAN 2 CONTENTS Safety requirements 3 Introduction 5 Use 5 Delivery set 5 Designation key 5 Technical data 5 Design and operating logic 8 Mounting and set-up 8 Connection to

More information

1. Information before installation General terms of delivery, storage and transport

1. Information before installation General terms of delivery, storage and transport EN Read this manual carefully before installing, maintaining or repairing this device! The symbol indicates important information that must be taken into account in order to avoid risk of personal injury

More information

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable Smart Smart IR model (check applicable) is recognized as serviceable Service instruction SALES DATE MANUFACTURED ON (DATE): SOLD APPROVAL MARK SMART-EN-04 BLAUBERG Company is happy to offer your attention

More information

Operating Manual MS220DA

Operating Manual MS220DA ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN

More information

Magnetic Stirring Systems with Heat

Magnetic Stirring Systems with Heat Sharing your passion for making jewelry. Products. Service. Know-how. Magnetic Stirring Systems with Heat 335-212 Digital Ceramic Magnetic Stirring System with Heated Stand 335-211 Ceramic Magnetic Stirring

More information

OWNERS INSTRUCTION MANUAL

OWNERS INSTRUCTION MANUAL Congratulations on your purchase of a Kent Portable Electric Appliance. Please read the following instructions carefully before use and retain for future reference. BEFORE FIRST USE Read and follow all

More information

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised: Instruction Manual Bottle Cooler Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com Issued: 06-11-2018 Revised: WARNING Only qualified service technicians should install and service

More information

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 EKF EC kitchen extract fan range Installation and Wiring Instructions Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS.

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

HD3D Forced-Air Heater

HD3D Forced-Air Heater Installation, Operation and Maintenance Instructions HD3D Forced-Air Heater Corrosion Resistant/Hose Down PF200-8 6-30552-00 July 207 Table of Contents Section Page. Warnings... 3 2. Optional Equipment...

More information