SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3
|
|
- Jeffrey Sanders
- 6 years ago
- Views:
Transcription
1 GUARANTEE CERTIFICATE Date of assembly Stamp and signature of the fitter GUARANTEE VOUCHER 1 GUARANTEE VOUCHER 2 GUARANTEE VOUCHER 3 GUARANTEE VOUCHER 4 GUARANTEE VOUCHER 5 Cat. no. Factory no. Date of production... loc... WATER HEATERS Poland G UBCZYCE ul. Raciborska 36 tel , fax ELECTRIC STORAGE TAP WATER HEATERS EXCHANGERS FOR TAP WATER HEATING SG-WS type volume: 80, 100, 120, 140, 200, 300 and 380 dm 3 Suspended Upright With a helical coil Bivalent with two coils Without a coil ENAMELLED CONTAINER + MAGNESIUM ANODE USER S GUIDE GUARANTEE CERTIFICATE
2 1. HEATER SPECIFICATION The hot tap water exchanger is intended for heating water and storing heated water. It can be used in households, institutional food service and restaurants, corporate social rooms, etc. Heater is suitable only for work in UPRIGHT position. It can be connected to the water supply system with pressure not exceeding 0.6 MPa (ca.6 atm.). Water can be heated by a helically coiled central heating exchanger (i.e. large surface coil) connected to the central heating boiler or additionally using an electrical heating element. Possibility of connecting it to the central heating boiler or electrical system ensures high savings in use of the exchanger, as water is headed by the central heating exchanger in winter (i.e. coil) hence it does not consume any electrical power. However, if the stove is not fired up, water is heated by an electrical heating element. Helical coil has large surface of heat exchange and, consequently, enables quick heating of large amounts of water. The basic model is a hot tap water exchanger with one helical coil shown in figure 4 and 5. Our offer includes exchangers with two helical coils, so-called bivalent coils, shown in figure 6 (with one coil to the central heating system, and the other to the solar heating system). The lower coil cooperates with a solar collector and the upper one - with the central heating boiler or a heating pump. In the lower part of the container, on the flange, we may additionally fit an electrical heating element use for warming up water in case of lower sun activity, outside of the heating season (two shields of sensors are located underneath the heating element). Anti-corrosion protection of the container is vitreous enamel fired in 850 C; the additional protection element is a large magnesium anode. Heaters are insulated with ecological polyurethane or polystyrene foam, which reduces heat loss to the absolute minimum. Location of all connections, connector pipes and their sizing is illustrated in the figures enclosed. 2. CONSTRUCTION The main part of the heater is a container in which water is heated. The container is made of enamel steel sheet (vitreous enamel). Holes in the bottoms of the container are closed with plugs. Two connector pipes of the coil to connect the central heating boiler and the connector pipe of cold water inlet from the water supply system and hot tap water outlet are located next to each other on one side of heater body. Additionally, there is also a hole for circulation connection and sensor shield, to which a sensor from the thermostat of the central heating boiler can be connected, ended with a sleeve 1/2". In upright containers with an electric set, the electrical heating element and the thermoregulator are located on the side, as shown in fig.1 or fig.2, in the lower or the middle part of the body, whereas the magnesium anode is located in the plug of the upper bottom. In wall-suspended containers, fig.3 NEPTUN KOMBI, the electrical heating element, the magnesium anode, connector pipe of cold water inlet and hot tap water outlet are located in the lower bottom. Next to the container body, there is the coil inlet and outlet, the hole for circulation connection and the sensor shield (to which a sensor of the thermostat of the central heating boiler can be connected) ended with a sleeve 1/2". In the electrical cover, there is a red control lamp that signals electric power consumption, and an orange lamp that signals connection to the electrical system, as shown in the wiring diagram 230 V. 3. TECHNICAL DATA (exchangers with a single helical coil) -2- GUARANTEE CERTIFICATE No. Date of receipt Repair description Repair date signature
3 Loss of pressure Quantity of heating water in m 3 /h Resistance of flow mbar Key Resistance of flow Quantity of heating water TECHNICAL DATA - bivalent exchangers (with a double helical coil)
4 Loss of pressure Quantity of heating water in m 3 /h Resistance of flow mbar Key 200 lower coil 200 upper coil 300 lower coil 300 upper coil 400 lower coil 400 upper coil Resistance of flow Quantity of heating water NOTE! 1. Connect the heater to the central heating system or electrical system only after the heater is filled in with water. 2. The safety valve hast to be assembled directly before the heater on the cold water feed pipe. Use only and solely valves adjusted to storage water heaters that also include a non-return valve. 3. There can be no additional devices (e.g. a cut-off valve, a non-return valve etc.) between the safety valve and the heater. 4. Do not use the heater without operational safety valve. Check operation of the safety valve every 14 days by turning the hood right or left so that there is a discharge from the side external outlet. Then turn the hood in the opposite direction until it clicks in the previous position and press it down to the valve body. Note - there is a possibility of hot water discharge. The company disclaims any responsibility for malfunctioning of the safety valve resulting from incorrect valve fitting. The maximum pressure of fully open safety valve cannot exceed 0.67 Mpa. 5. Do not try to prevent water from dripping from the safety valve - do not plug the discharge hole of the safety valve. If water constantly leaks out from the safety valve, it means that the pressure in the water supply system is too high or the safety valve is out of order. The valve outlet should be directed downwards. It is recommenced that a funnel that discharges water is placed under the valve. It is also possible to place a hose on the outlet that discharges water leakage arising when opening the safety valve. The hose should be resistant to temperature up to +80 C, have a 9 mm internal diameter and 1.2 m maximum length, led to the outlet with a downward slope (min. 3%) in the environment in which temperature does not fall below 0 C. The hose required protection against decreasing opening area (folding, plugging) and its outlet should be visible (to check valve operation). 6. There cannot by any devices that cause the so-called water hammer in the system in which the heater is fitted, e.g. a ball valve used as a flushing valve. 7. Switch the heater off immediately if smoke comes out of any battery (notify the manufacturer). 8. Check the protection of the heater by measuring neutral grounding effectiveness at least once a year. 9. Connection of the heater to the mains without a grounding pin may result in electrocution in case of failure of electric equipment. 10. To maintain the heater in good operational condition, remove scale from the heating element at
5 GUARANTEE TERMS 1. Method of repair is determined by the manufacturer. 2. Replace the magnesium anode at least every 12 months (please keep the purchase receipt of the anode) Regular replacement of the magnesium anode is the condition to maintain the guarantee for the container. 3. In case of defects of the product, notify the service, hotline: Free repairs of damages attributable to the manufacturer will be remedies within 14 working days from the date of submission. DO NOT DISASSEMBLE THE HEATER. Keep the purchase receipt of the heater for review by the service. Multiple repairs do not include: replacement of the magnesium anode, replacement of the seal etc. 4. The basis of guarantee repairs is a purchase invoice and the guarantee certificate that is complete, filled in correctly, ed by the relevant store and fitter, and contains no adjustments. Keep the guarantee certificate throughout the whole guarantee period. 5. In any cases not regulated herein, relevant regulations of the Civil Code shall apply. 6. Any mechanical damages of the heater void the guarantee. 7. Assemble the heater in such a way to ensure free access (e.g. for maintenance, repairs or replacement). The manufacturer is not responsible for any possible inconvenience or costs resulting from casing disassembly. 8. The guarantee for the sold consumer product does not exclude, limit or suspend any rights of the buyer resulting from inconsistency of the product with the agreement. Guarantee for enamelled container 80 * 140 dm3-48 months. Guarantee for enamelled container 200, 300, 380 dm3-42 months. Other parts -12 months. The guarantee covers the aforementioned period, no longer, however, than the guarantee period plus 12 months from the manufacture date of a given product. UNAUTHORISED REPAIRS OR MODIFICATIONS VOID THE GUARANTEE. least 2 a year. If the conditions do not enable application of suitable acids, it can be done by crushing the scale layer (make sure you do not damage heating element surface). 11. At least once a year, replace the magnesium anode in enamelled containers (excluded from the guarantee service). 12. To extend service life of the container and ensure effective operation of the safety valve, use filters that eliminate impurities. 13. Do not remove the cover if the heater is connected to power supply. 14. The manufacturer is not responsible for the quality of water (e.g. contained chemical compounds, scaling) and the related inconvenience. 15. Any smells and dark water coming out of the heater result from formation of hydrogen sulphide by bacteria reducing sulphate content that live in water of low oxygen content. If container cleaning, magnesium anode replacement and start-up with temperature > 60 C bring no results, we recommend using a titanium anode connected separately to the power supply. 16. If the cold water system that feeds the water to the heater has a non-return valve or a different device that operates as a non-return valve e.g. pressure regulator, the water system needs to be fitted with a collective diaphragm vessel of volume that is at least 5% greater than boiler volume. 17. Do not use plastic pipes to connect the heaters that are not intended to operate at temperature 100 C and pressure 0.7 MPa. 18. Assemble the heater in such a way to ensure free access (e.g. for maintenance, repairs or replacement). 19. Any mechanical damages of the container (or the heater) void the guarantee. 4. INSTALLATION OF THE HEATER The heater has to be installed by a fitter with relevant licence Heater installation needs to be recorded on the guarantee card. Because of its construction, the heater can be assembled only VERTICALLY. Connect the heater (with possibility of disconnection e.g. for maintenance) directly to the water supply system with pressure not more than 0.6 MPa; the minimum pressure cannot be lower than 0.1 MPa - ca. 1 atm). If the pressure in the water supply system is more than 0.6 MPa, it is necessary to reduce it by application of a pressure reducing valve. Assemble the safety valve e.g. ZB4 or ZB8 by FACH Cieszyn or ZB7 or ZB9 by Orkli (Spain) on the cold water feed pipe according to the arrow indicating the direction of water flow that is located on valve body. In the heater, the safety valve enables to decrease the pressure without water outflow outside through its flow to the feeding system. It opens the outflow in case of differential pressure in the heater and the system amounting to /-0.02 Mpa; therefore, in the distance of 5 meters from the safety valve, the cold water feed pipe should endure temperature +90 C (due to the possibility of hot water flow from the container to the system). The discharge hole of the safety valve needs to be constantly open - connected with the atmosphere. The diagram showing connection of the heater in an open system is shown in fig.1. The diagram showing connection of the heater in a closed system (with a diaphragm tank) is shown in fig.1. The heater can be connected to the power supply system only by a socket type 2P- 0/230V/10A (a plug-in socket with a grounding pin). For temporary disconnection of the water heater, remove the plug from the socket. If this action is taken in winter and it is possible that water in the heater may freeze, drain the water by turning on the drain plug KS (fig.1). -8- Fig.1 N - collection tank of the open system Zb - safety valve* Z1 - cut-off valve on cold water inlet Z2 - cut-off valve on hot water inlet Z3 - cut-off valve on water supply from the central heating system to the coil O - heater body Ks - drain plug c - circulation g. el. - electrical heating element W. S. - helical coil tr. - thermometer cz. - sensor shield -5-
6 Figure 2 N - diaphragm tank Zb1 - safety vale of the heater* Zb2 - safety valve of the central heating system* Z1 - cut-off valve on cold water outlet Z2 - cut-off valve on hot water inlet Z3 - cut-off valve on water supply from the central heating system to the coil O - heater Ks - drain plug c - circulation g. el. - electrical heating element W. S. - helical coil Am - magnesium anode in upright containers (in suspended containers, next to the heating element that is located in the lower bottom, there is also a magnesium anode) cz. - sensor shield Wiring diagram 230 V figure heating element 2 - thermoregulator 3 - temperature limiter BOT Ls - signalling lamps L1 - phase cable 7. TROUBLESHOOTING Figure 3 Wiring diagram 400 V 1 - a cable with a male connector 2 - thermostat with temperature limiter 3 - signalling lamps 4 - heating element N - neutral cable PE - protection cable Figure 4 or Figure 5 1. hot tap water outlet G1" 2. inlet of hot water from central heating G1" 3. circulation G3/4" 4. sensor shield G1/2" 5. water outlet to central heating G1" 6. safety valve* 7. cold water inlet G1" 8. magnesium anode 9. inlet on the thermometer G1/2" 10. inspection hole or inlet for the electric heating element *not included in the basic price 1. hot tap water outlet G3/4" 2. hot water inlet from central heating G3/4" 3. circulation G3/4" 4. sensor shield G1/2" 5. water outlet to central heating G3/4" 6. safety valve* 7. cold water inlet G3/4" 8. magnesium anode 9. inlet on the thermometer G1/2" 10. inspection hole or inlet for the electric heating element * not included in the basic price
Water heater type SGW(S) Vulcan
Cat. No./ Serial No.... QC Date of manufacture... Installation and Operating Manual / Warranty Card Water heater type SGW(S) Vulcan Capacity: 100 l 120 l 140 l 200 l Protection: Magnesium anode Titanium
More informationWATER HEATERS FOR CENTRAL UTILITY WATER ENSOL/1
INSTALLATION AND USER S MANUAL WARRANTY TERMS WATER HEATERS FOR CENTRAL UTILITY WATER 100 150 220 250 300 400 500 Contents: 1. Construction and use. 3 2. Safety and condition of use 7 3. Installation..
More informationHOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD
HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT 200 300 500 INSTALLATION AND OPERATION MANUAL WARRANTY CARD Contents: 1. Structure and Intended Use... 3 2. Safety devices and conditions for safe
More informationSpecification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200
HEWALEX INTEGRA HEATER INSTALLATION MANUAL 1. Description The INTEGRA heater is designed for accumulating heat generated by such sources as: a solid fuel burner, a fireplace, a heat pump and solar collectors.
More informationWATER HEATERS EN - flyer 03/z/2018 Made in Poland
WATER HEATERS EN - flyer 03/z/208 Made in Poland www.galmet.eu ELETRI WATER HEATERS TYPE SG NEPTUN 2, SG VULAN Neptun 2 / Vulcan Thermostat with precise temperature control. Possibility to order the water
More informationSTORAGE WATER HEATERS
Owners Manual STORAG WATR HATRS RBC 200, RBC 300, RBC 400, RBC 500, RBC 500HP, RBC 750, RBC 1000, RBC 1000HP, RBC 1500, RBC 2000, RBC 3000 N v. 1.4 CONTNTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection...
More informationENAMELED INDIRECT WATER HEATERS
INSTRUCTIONS ENAMELED INDIRECT WATER HEATERS ST-300DE HEAT PUMPS Please read this manual carefully before installing the heater! Dear Customer, Sinclair Corporationt Ltd. thanks you for your decision
More informationwith insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD
HEATER type EJK maxi with insulated heating elements for water heaters 3000 W 4500 W 6000 W 9000 W INSTALLATION AND USER MANUAL WARRANTY CARD Zakład Urządzeń Grzewczych Elektromet 48-100 Głubczyce, Gołuszowice
More information=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element
=Classic range= Classic range technologies Magnesium anode The magnesium anode is located in the centre of the enamelled tank and provides excellent protection against corrosion; this anode is consumed
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL STATIONARY ELECTRICAL HOT WATER TANKS OKCE 100 NTR/2,2 kw OKCE 125 NTR/2,2 kw Družstevní závody Dražice - strojírna s.r.o. Dražice 69, 294 71 Benátky nad Jizerou Phone.:
More informationTANK TYPE INDIRECT WATER HEATERS
Operation and Installation Manual TANK TYPE INDIRECT WATER HEATERS OKC 80 NTR/Z OKC 100 NTR OKC 100 NTR/HV OKC 100 NTR/Z OKC 125 NTR OKC 125 NTR/HV OKC 125 NTR/Z OKCV 125 NTR OKC 160 NTR OKC 160 NTR/HV
More informationLEMET GREENLINE 30, 50, 80, 100, 120 and 200 Liter (vertical and horizontal) GREENLINE ECOWAY SMALL
OPERATION AND INSTALLATION MANUAL WALL-MOUNTED, UNVENTED ELECTRIC WATER HEATERS LEMET GREENLINE 30, 50, 80, 100, 120 and 200 Liter (vertical and horizontal) LEMET ECOWAY 50, 80, 100, 120 and 200 Liter
More informationINDIRECT WATER HEATERS
INSTRUCTIONS INDIRECT WATER HEATERS ST-300D, ST-200D HEAT PUMPS STAINLESS STEEL INDIRECT FIRED WATER HEATERS ST-200D, ST-300D 1. Product Description Indirect fired water heaters ST-200D and ST-300D are
More informationWHE 2.24 / WHE 2.24 FF
EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationOPERATING and INSTALLATION MANUAL
OPERATING and INSTALLATION MANUAL STATIONARY ELECTRICAL WATER TANKS OKCE 160 NTR / 2,2 kw OKCE 200 NTR / 2,2 kw OKCE 250 NTR / 2,2 kw OKCE 300 NTR / 2,2 kw OKCE 300 NTR / 3-6 kw OKCE 200 NTRR / 2,2 kw
More informationSpeedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF05K, SF10K and SF15K Instruction Manual Version 3.0 June 2010 HYCO SPEEDFLOW UNVENTED WATER HEATER MODELS SF05K (5 Litres) SF10K (10 Litres) AND SF15K
More informationInstallation and Operating Instructions. Models: T4-12LOW-9IS
Installation and Operating Instructions Models: T4-12LOW-9IS Dear Valued Customer, Thank you and congratulations on purchasing your new Parmco appliance. All Parmco products are made to the highest quality
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL INDIRECT HOT WATER TANKS OKC 100 NTR OKC 100 NTR/HV OKC 80 NTR/Z OKC 125 NTR OKC 125 NTR/HV OKC 100 NTR/Z OKC 160 NTR OKC 160 NTR/HV OKC 125 NTR/Z OKC 200 NTR OKC 160
More informationTechnical documentation: S1 S2 S3 S4
Technical documentation: S1 S2 S3 S4 1 Table of contents: 2 1. Introduction 3 1.1 Precautions 3 1.2 Transport 3 1.3 Package content 4 1.4 Use and principle of operation 4 2. Schematic diagram 4 2.1 Construction
More informationSECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from
More informationStorage Tanks Type NADO
Operation and Installation Manual Storage Tanks Type NADO Družstevní závody Dražice strojírna s.r.o. (Works Cooperative - Dražice Machine Plant, Ltd.) Dražice 69 29471 Benátky nad Jizerou Tel.: 326 370911,
More informationINSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET
INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 TEMPERATURE ALTERNATIVES 3 PACK CONTENTS 4 PRE-INSTALLATION INFO 5-6 FAUCET INSTALLATION 7 ADJUSTING
More information100 Series Maxi Internal Filters
100 Series Maxi Internal Filters Important Safeguards To guard against injury, basic safety precautions should be observed, including the following: 1. Read and follow all safety instructions and important
More informationPortable Refrigerator
Portable Refrigerator Owners Manual Single door 40 litre 65 litre 80 litre 125 litre Double door 74 litre 95 litre 2009 Introduction The National Luna range of portable fridges and freezers are high-performance,
More informationInstallation manual Operating instructions
WIKORA GmbH Friedrichstr. 9 89568 Hermaringen Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Operating instructions DHW storage tank UNO/DUO/H/WPSOL Installation
More informationTechnical documentation DTR
Technical documentation DTR ENG TECHNICAL DOCUMENTATION Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT. USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL
More informationCENTRA-COIL QUALITY HOT WATER SERVICE
CENTRA-COIL QUALITY HOT WATER SERVICE INSTALLATION AND OWNERS MANUAL WARNING This water heater should be installed in accordance with the requirements of AS 3500.4. The owner should also be aware of any
More informationPOWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual
POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009 Hyco POWERFLOW
More informationINSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3
INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ 4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700
More informationSECTION ELECTRIC WATER HEATERS
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More informationINDIRECT SYSTEM FOR FROST LOCATIONS
SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer
INSTRUCTION MANUAL Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES SS3N SS3V / SS5N SS5V / SS5NH SS5VH Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo
More informationHeat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions
Heat Accumulation thermal stores hot water storage tanks www.regulus.eu HOT WATER STORAGE TANKS WITH NO HEAT EXCHANGER R0BC Hot Water Storage Tanks Hot Water Storage Tanks permitting installation of an
More informationInstallation & Operating Instructions
PREMIUM Installation & Operating Instructions m AQP-3TAP-SS Platinum Water Dispenser Hot/Cold & Room Premium Selection Congratulations on your purchase of an Aquaport Platinum Water Dispenser Thank you
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL ELECTRIC WATER HEATER TO - 20 Družstevní závody Dražice-strojírna s.r.o. (Works Cooperative - Dražice - Machine Plant, Ltd.) Dražice 69, 294 71 Benátky nad Jizerou tel.:
More informationCROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15
CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm
More informationSECTION ELECTRIC WATER HEATERS
SECTION 22 36 01 ELECTRIC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationDTC 100/2 TDG. User s manual Installation and maintenance instructions
Differential thermostat for solar systems and combined heating sources and regulation of burner or electric heating element DTC 100/2 TDG User s manual Installation and maintenance instructions FIRŠT-ROTOTEHNIKA,
More informationTechnical documentaton DTR. Farmer
Technical documentaton DTR Farmer ENG TECHNICAL DOCUMENTATON Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT. USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL
More informationTechnical documentaton DTR. Farmer
Technical documentaton DTR Farmer ENG TECHNICAL DOCUMENTATON Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT. USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 22 3300 - ELECTRIC, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationPowerflow Unvented water heater
Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5 Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing
More informationRoof Mount Solar Hot Water System USER MANUAL
Roof Mount Solar Hot Water System USER MANUAL Congratulations on your purchase of the Solargain Solar Hot Water System. Please keep this copy of your owners manual as it contains important information
More information52 SAN LUCAS CEILING FAN
52 SAN LUCAS CEILING FAN Owner s Manual Models #20551 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-
More informationInstallation Manual STOR C. Solar combination storage cylinder. Installation Manual
Installation Manual STOR C Solar combination storage cylinder EN Installation Manual 2MANUALE INSTALLATORE Dear Installer, Thank you for choosing a BERETTA STOR C, combination storage cylinder. You have
More informationRoth fixed-value control set with high-efficiency pump
Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationOwner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters
Owner s Manual Electric Storage Water Heaters Standard Models: 80T118, 80T124, 80T136, 125T118, 125T136, 160T124, 160T136, 250T136, 315T136, 315T236, 315T248 400T136, 400T236 An H at the end of the model
More informationRENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05
THERMAL SOLAR ENERGY CATALOGUE OCTOBER 2008 INDEX RENEWABLE ENERGY THERMAL SOLAR ENERGY RENEWABLE ENERGY...pag. 05 SISTEMA CS 25 RN TAU... pag. 6 SISTEMA CS 25 RN - CS 25 RN PLUS... pag. 8 SISTEMA CSL
More informationALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.
INSTRUCTION MANUAL DATE JULY 2017 v2.0 HOTLINE 1300 AQUATEC MODEL 03AS310 03AS311 AQP All in One 1000 Instructions.indd 1 CONGRATULATIONS ON YOUR PURCHASE OF THIS PRODUCT BY AQUAPRO, THE ANSWERS FOR YOUR
More informationTH100 Three in One Instant Hot Water Tap
TH100 Three in One Instant Hot Water Tap Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu
More informationSUN EQUINOX HEATING SYSTEMS
SUN EQUINOX HEATING SYSTEMS HIGH-EFFICIENCY HOT WATER SOLUTIONS INSTALLATION & OPERATION MANUAL Production Number: Customer Contact Information Other Resources 260-65-5605 http://www.solarusagenow.com
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS, for the User and the Installer. SMART Line. Smart ME A Y2000 B
INSTALLATION, OPERATION AND MAINTENANCE INSTCTIONS, for the User and the Installer SMART Line Smart ME 00-300 - 400-600 - 800 A00859-66Y000 B TABLE OF CONTENTS GENERAL RECOMMENDATIONS...4 PRODUCT INFORMATION...5
More informationNiles Steel Tank Hot Water Generator Installation and Operation Manual
Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....
More informationgorenje GBFU SIMPLICITY
gorenje GBFU SMPLCTY Dear buyer, we thank you for purchase of our product. PROR TO NSTALLATON AND FRST USE, PLEASE CAREFULLY READ THESE NSTRUCTONS This water heater has been manufactured in compliance
More informationFRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE
FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE Introduction Thank you for purchasing this Franke product, which has been designed and manufactured to the highest quality standards.
More informationUSER MANUAL. 60cm, 3 burners, Hob AKC 630
USER MANUAL 60cm, 3 burners, Hob AKC 630 For your safety These instructions have been drawn up for your safety and that of others. You are therefore requested to read them carefully before installing
More informationAccumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU
Installation, operation and maintenance Accumulator tank 1000, 750 and 500 litres Aqualux Teknik Aqualux B Aqualux 750 C Aqualux 750 Teknik with bivalent shunt, optional extra 2012-02-08 ver.: Supersedes:
More informationInstallation instructions Combined fridge-freezer for integrated use, door-on-door
Installation instructions Combined fridge-freezer for integrated use, door-on-door 100713 7085634-00 IC.../ ICB.../ ICU...... LC/ LP General safety information Contents 1 General safety information...
More informationInstallation Manual. Models 99168, 99169, 99170
Wet-Rated Globe Fitter Installation Manual Compatible with: 2xxxx Types A - Z 51000-58999 fan series 59500-59999 fan series Select Casablanca Fans Models 99168, 99169, 99170 BEFORE YOU BEGIN Read entire
More informationDual Spin Mop Robot Cleaner
Dual Spin Mop Robot Cleaner Copyright 2017 EVERYBOT Inc. All rights reserved. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by any
More informationUSER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM
USER MANUAL 80 cm 2 burners, glass hob AKC 820C/BLM For your safety These instructions have been drawn up for your safety and that of others. You are therefore requested to read them carefully before installing
More informationAquience 1200/1500 R
Aquience 1200/1500 R Congratulations, you have purchased one of the fi nest quality aquariums available. This product will give you many years of excellent service when installed and maintained correctly.
More informationIndustrial Dehumidifier Operating Instructions. Model: VG 1500
Industrial Dehumidifier Operating Instructions Model: VG 1500 Read and save these instructions. This instruction manual provides important information concerning the use and care of the B-Air Vantage 1500
More informationAMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL
AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL Ceiling Fan Weight Including Accessories: 21.00 Lbs. READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Tools and Materials Required...
More informationO Pro electric storage water heater
O Pro electric storage water heater PREMIUM SERIES MAINS PRESSURE ELECTRIC STORAGE WATER HEATERS DOCUMENTATION FOR INSTALLATION AND OPERATION New Zealand INDOOR INSTALLATION ONLY MODEL 272014 MODEL 282029
More informationInstallation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)
Installation instructions Pump Group For wall hung gas-fired condensing boiler GB6-50/65/80/00 6 70 648 7-000.TD UK/IE 6708374 (04/09) Contents Contents Key to symbols and safety instructions....................
More informationInstallation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual
Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information
More informationChecking the components Safety information Operating the product Other information
1 Feature of your product Always provide powerful elimination performance 2/4 Samsung SPi device has been applied on the left/right side of the product for quick and powerful elimination performace. Luxurious
More informationWH-TD20B3E5 WH-TD30B3E5
Order No: PHAAM1004143C2 WH-TD20B3E5 WH-TD30B3E5 WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain
More informationMW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.
MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK IMPORTANT: This booklet should be given to the customer after installation and demonstration. Description of water heater 1) Hot water outlet 2) Temperature
More informationINSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS
INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing
More informationService booklet for the Engineer for Gas Condensing Boilers
Service booklet for the Engineer for Gas Condensing Boilers 6 720 610 577-00.10 ZWB 7-29 CC1 GC-Number: 47 108 05 ZB 7-28 CS1 GC-Number: 41 108 02 ZWB 7-27 HE combi GC-Number: 47 311 55 ZWB 7-25 HE combi
More information17 OPERATING AND INSTALLATION MANUAL - EN
17 OPERATING AND INSTALLATION MANUAL - READ CAREFULLY THE BELOW INSTRUCTIONS PRIOR TO THE INSTALLATION THE HEATER! Dear Customer, The Works Cooperative of Dražice Machine Plant, Ltd., would like to thank
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationSRCC OG-300 Certified Solar Water Heating System
SRCC OG-300 Certified Solar Water Heating System Free Hot Water Collector 4000 Series Liberty 4002, 4003 2011043A - Freedom - 5002 XG 2011043B - Freedom - 5003 XG 2011046A - Freedom - 5002 XE 2011046B
More informationINSTRUCTION MANUAL (English version) Water still
INSTRUCTION MANUAL (English version) Water still Model : Brand : W4000 Merit Merit Water Still W4000 & W4000/EURO Cooling water inlet Condenser Constant level control Boiler Thermostat reset buttons To
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationGEYSERWISE INSTRUCTION MANUAL
GEYSERWISE INSTRUCTION MANUAL GEYSERWISE MAX DELTA T ALL IN ONE HOT WATER MANAGEMENT Before operating and installation, carefully read all instructions. Do not discard this manual. INDEX 1. Package Contents
More informationTECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES
TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES ENG Technical documentation Table of contents 1. INTRODUCTION 1.1 PRECAUTIONS 1.2 TRANSPORT 1.3 PACKAGE CONTENT 1.4 USE AND PRINCIPLE
More informationInstallation & Manual. Model T-25
Installation & Manual TR Central Heating Stove With Solid Fuel Model T-25 Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of conformity! TABLE OF CONTENTS
More informationL A signature series TA T N E RE O, A L L A T S IN
signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam
More informationOperators manual Slim/B Water heater
Operators manual Slim/B Water heater Isotemp Slim water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationGEM TRAP FITTING & MAINTENANCE INSTRUCTIONS
GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure
More informationComponents for solar heating systems
solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised
More informationOperating Instructions Wine storage refrigerator 12/
Operating Instructions Wine storage refrigerator 12/98 7080641 1 The wine storage refrigerator you have purchased differs from normal refrigerators in that it is suitable for long-term storage of wine.
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL Tank-type water heaters for combined water heating by means of AC/DC current for vertical assembly LX ACDC/M+K 100 A,B,C LX ACDC/M+K 125 A,B,C LX ACDC/M+K 160 A,B,C LX
More informationMercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040
Mercury RV Water Heaters Duoetto HCE-10 Dual Voltage 12VDC/240VAC www.ausj.com.au sales@ausj.com.au P.O. Box 777, Leichhardt, NSW 2040 Thank you for your purchase of the Duoetto Dual Voltage Water Heater!
More informationUser manual Electronic air ioniser Air purifier
User manual Electronic air ioniser Air purifier Attention! Do not touch the needles when unit turned on! Function: By the combination of three of the world s most recognized technologies of purification,
More informationEVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1
EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1 Thermann Solar Hot Water System - Owners Manual Thank You Thank you for purchasing a Thermann solar hot water system. Please
More informationFlamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS
WATER HEATERS, STORAGE TANKS 6 Flamco and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS 2007 edition / UK Flamco glass lined water heaters for potable and heating installations Flamco
More informationSPRINGHILL 44 CEILING FAN
SPRINGHILL 44 CEILING FAN MODELS #50184, 50185 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday,
More informationKTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.
KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4. en Our products have been designed and manufactured in such a way to ensure that all the quality, functionality and
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.
INSTRUCTION MANUAL Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel: [81]-(0)79-422-1122
More informationUSER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER
USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER GREENGLO MAINS PRESSURE INTEGRATED WATER HEATER SINGLE COIL SERIES & DOUBLE COIL SERIES GREENGLO SAVER Customer Congratulations for choosing a GreenGlo
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationROTARY VACUUM EVAPORATOR RVO 004
INGOS Ltd. ROTARY VACUUM EVAPORATOR RVO 004 User manual PRAGUE April 11 2006 INGOS Ltd. Laboratory Instruments division Page 1 Producer : Laboratory Instruments division of INGOS Ltd. Supplier and service
More informationUser Guide. BlueairMedical FEATURING HEPASILENTª TECHNOLOGY
User Guide BlueairMedical FEATURING HEPASILENTª TECHNOLOGY Blueair Medical THANK YOU FOR CHOOSING BLUEAIR Ready to start breathing cleaner air? First, read this User Guide to ensure that you use the Blueair
More information52 BARSTOW CEILING FAN
52 BARSTOW CEILING FAN Owner s Manual Models #20519 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-
More informationInstallation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro
Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2
More information