1 OX120U5, OX120U10 OX120B5, OX120B10 OX120U10R & OX120U5R INSTALLATION, OPERATION & SERVICE INSTRUCTIONS HYDROGEN SULFIDE REMOVAL SYSTEMS NO MEDIA NO CHEMICALS NO WASTE PRESSURE BOOSTING SYSTEM MODELS: OX120B5, OX120B10 STANDARD SYSTEM MODELS: OX120U5, OX120U10 STANDARD SYSTEM / RAW WATER BYPASS (for less than 1 PPM sulfide only) OX120U5R, OX120U10R US Patents: 6,080,306; 6,074,562; 6,481,456; 6,663,771; 6,884,358; 7,125,003 AFTER COMPLETING THE INSTALLATION LEAVE THIS MANUAL WITH THE END USER
2 TABLE OF CONTENTS GENERAL INFORMATION 2 CHECKLIST 3 SYSTEM COMPONENTS 4 PLUMBING THE SYSTEM 5 PLUMBING THE BOOSTED SYSTEM 7 WIRING THE BOOSTER PUMP 10 SYSTEM START-UP 11 TROUBLESHOOTING 12 WARRANTEE 14 GENERAL SAFETY INFORMATION Inspect for shipping damage and notify freight carrier and supplier immediately if damage is present. Annual maintenance must be done purge system of precipitants and to avoid restriction or contamination. System should be purged more often if iron or organics are present. Like any pressurized tank the tank or connections can over time weaken and leak or burst, possibly causing injury and or property damage. Repair any leaks and locate system where potential damage is minimized. Consult a water quality professional to test or evaluate your water and recommend any other necessary treatment for bacteria, chemical or other possible contaminants. Electrocution and explosion hazard! Before working on this product turn of the power and release all the pressure in the system. Product requires clean air. Locate in a well-ventilated area with access to fresh air. Surrounding area should be free from fumes, exhaust, chemicals, odors or similar toxins, which could be captured into the system. As in all water storage vessels and plumbing products, bacteria can grow especially during extended times of non-use. Consult your local plumbing and or treatment professional regarding any steps you may take to safely disinfect your home s plumbing system. READ CAREFULLY THE INSTALLATION, OPERATING AND SERVICE INSTRUCTION MANUAL TO AVOID PERSONAL INJURY AND PROPERTY DAMAGE AND TO ENSURE SAFE USE AND PROPER CARE OF THIS PRODUCT A QUALIFIED PROFESSIONAL MUST INSTALL THIS PRODUCT. 2
3 2. CHECKLIST The system utilizes high-pressure water and air to transform hydrogen sulfide into water and elemental sulfur. This solid collects on the bottom of the tank to be periodically purged. This process requires a minimum contact time of 55 minutes (on 68 F water) per PPM sulfide to complete. The system will provide on demand or all at once, sulfur free water equal to 38% of the water storage capacity and 75% of the storage capacity of the contact tank. Using the chart below, ensure the system you select is properly sized for the job, with the additional contact tanks if required. This sizing chart is for average households with typical water use patterns. Large hot tubs or other high volume fixtures should be added to the typical contact volume required. For example, a 2-person home with 2-ppm sulfide and an 80-gallon whirlpool tub would require an additional 80 or 120-gallon contact tank. Use the OX120B5 or OX120U5 for 5-9 GPM applications, the OX120B10 or OX120U10 for GPM applications. Use the OX120U5I for 5-9 GPM treated and 30 GPM raw applications by adding the bypass check as shown in 4.A.3. Use the Oxidizer 80 or 120 gallon well tank with 15 GPM Inductor and optional 1-1/2 hp pressure booster for GPM treated applications instead of the models in this manual. The well pump must be able to supply the minimum gallons per minute to the system at a pressure of at least 80 PSI to not use a booster pump. Sulfide Concentration SIZING CHART System & Number of Additional Contact Tanks Recommended 15 PPM + (2) CT120 + (3) CT PPM 5 PPM + (2) CT120 2 PPM + (2) CT120 + (2) CT120 1 PPM + (3) CT120 + (2) CT120 + (3) CT120 + (2) CT120 + (2) CT PPM Number of Residents MODEL TANK CAPACITY DIMENSIONS AND PERFORMANCE DATA TANK WIDTH HEIGHT MINIMUM -- TREATED FLOW BOOSTER PUMP SIZE REQUIRED INLET PRESSURE MAXIMUM WORKING PRESSURE PIPE SIZE OX120U5 120 GALLON GPM N/A PSI 100 PSI 1 NPS OX120B5 120 GALLON GPM ½ hp PSI 100 PSI 1 NPS OX120U GALLON GPM N/A PSI 100 PSI 1 NPS OX120B GALLON GPM ¾ hp PSI 100 PSI 1 NPS OX120U5R 120 GALLON GPM * N/A PSI 100 PSI 1 NPS OX120U10R 120 GALLON GPM N/A PSI 100 PSI 1 NPS CT GALLON GPM N/A N/A 100 PSI 1 NPS * Raw Water flow up to 30 GPM. System tank serves additionally as well tank with raw water bypass union check provided. Recommended accessories: Drain line for ¾ MPT pressure relief & 1 NPS tank drain 1 NPS pipe, shut-off valve, union & ordinary pipefittings and joint materials. 3/8 black poly tubing and connector 3
4 3. SYSTEM COMPONENTS RAW WATER BYPASS UNION CHECK VALVE (optional) Note: Items 4, 6, & 7 are bagged for the Standard kit only. Items 4 & 6 come with Booster 4
5 4.A PLUMBING THE SYSTEM (without a pressure booster) In order for the well pump to be eligible to drive the oxidation process through the Inductor on the standard system, the well pump must be able to supply a minimum of 5 gallons per minute to the system at a pressure of at least 80 PSI. If the pump is not capable of maintaining that pressure then use the booster pump which will also provide better pressure to the home. Sulfur concentrations over 10-ppm sulfide must have a minimum 90 PSI. Pressure on the well line from the well pump to the Inductor inlet may exceed 80 PSI. If you are using your own pressure booster, follow the directions under section 4.B PLUMBING THE SYSTEM WITH BOOSTER PUMP on page 7 substituting your own pump and pressure switch. Make certain that the pump performance curve is adequate before selecting any other pressure-boosting pump. If you need raw water for irrigation from the same well and are using the well pump without a booster pump, use the Raw Water Bypass option for 1-PPM sulfide. Use a different model, the Odor Oxidizer Pressure Tank with Raw Water Bypass option for 1-10 PPM sulfide or add a pressure booster to this model. Locate near drain adequate for the pressure relief or the momentary purge of sulfur compounds, which are trapped in the sump. The system should be installed in a dry location that provides adequate space for installation and service. As components age leaks may occur, therefore, do not locate in an area where water from the tank can cause property damage. Do not treat water over 100 F. Do not expose the system to temperatures below freezing as water freezing in the tank or components will break them. 5
6 4.A PLUMBING THE SYSTEM (without a pressure booster)(continued) 1 Position the Oxidation Tank as close to the well pump discharge as is practical using the Tank as the pressure tank for controlling the well pump. Also locate near the existing pressure switch so the control line can be as short as possible. See the installation diagram previous page. 2 Assemble the Air Inductor assembly as shown. Orient the pressure gauges so they can be read, but hand tight only. Inlet pressure gauge seals against an O-ring, however the system pressure gauge requires Teflon tape to seal. Install the Air Filter finger tight only as it may be removed later. Secure all unions hand tight. 3 Glue the outlet port of the Air Inductor to the Tank inlet. Note: If you are using the raw water bypass option, plumb a tee at the tank inlet and branch to the optional union check with the arrow towards the well pump. 4 Plumb the inlet of the Air Inductor to the well pump discharge line. Note: If you are using the raw water bypass option, Tee the check outlet to the well line at the Inductor inlet as shown. Do not reduce or restrict the well line. 5 Install a drain valve on the Tank drain and plumb the drain to the exterior or use a hose. Plumb the pressure relief to the exterior. Plumb the relief valve to a suitable drain. Failure to do so can result in flooding and property damage. 6 Remove the existing well pump Square D FSG pressure switch (if installed) and install the new pressure switch spring provided in the kit. This will give the desired pressure differential when adjusted later. Thread the ¼ Ell provided into the port on the pressure switch with Teflon tape finger tight. Loosen the compression nut then press one end of the ¼ tubing provided into the fitting so that the tubing is past the seal, then secure the nut finger tight. Plug the vacated switch connection. 7 Wire the pressure switch per local code. Secure the switch to the plumbing at a convenient location using the two switch clamps provided. The clamps attach to the switch from the bottom through the ground lug taps. Secure the ground to the new lugs the clamps provide. 8 Press the other end of the pressure control line from the pressure switch onto the control line fitting on top of the Air Inductor outlet. 9 Connect the vent line at the base to 3/8 polyethylene tubing (not provided) and run the length of tubing to the exterior. Air released from this line is humid and may corrode metal in the vicinity. Should the vent valve malfunction, water can spray from the line. Plumb the vent line to the exterior or to a suitable drain. 10 Plumb the outlet of the Tank with a ball valve to the treated line or contact tank inlet, if additional contact is needed. 11 When using a contact tank, install a drain valve on the Tank drain to the exterior as done in step 5, and then plumb the contact tank outlet to the treated line as done in step 10, or the next contact tank if additional contact is required. 6
7 4.B PLUMBING THE PRESSURE BOOSTED SYSTEM Locate near drain adequate for: The pressure relief and to drain the vessel. This system should be installed in a dry location that provides adequate space for installation and service. As components age leaks may occur, do not locate in an area where water from the tank can cause property damage. If installed outdoors in temperate regions, avoid roof drip edges that can concentrate rain fall onto the pump motor, or areas that flood and may submerge the motor. Any water treatment or handling equipment installed upstream must be vacuum resistant or vacuum protected in the event of a supply failure. Water pressure from the well must be from PSI. The flow rate must always be greater than 5 GPM. An interruption of the water supply can result in heat damage and potential failure and leaking at the booster pump. To reduce this risk, your product includes a temperature-sensing switch that is designed to turn off if the pump is over-heated. Do not alter or remove this sensor. Electrocution and explosion hazard! Before working on this product, turn off the power to the pump and release the pressure in the system. Never install two pumps that draw in parallel on the same suction line or artesian well line. One pump will cause the other to become vapor locked and not perform properly or over-heat. Do not allow partially cured glue or other plumbing debris to enter the booster pump or Inductor at start-up. Always flush lines. Do not over-tighten fittings. Plastic treaded fittings should be snug; unions should be hand tight only. Make certain the pump performance curve is adequate before selecting any other pressure-boosting pump. Wire the pressure booster to the pressure switch as indicated by the pump manufacturer in compliance with local codes. To make wiring the booster pump easier, prior to the installation determine the best available electrical source. Then following the instructions 5. Wiring the Pressure Booster: connect with the ½ nut and wire the pressure switch to the booster. Then select the proper voltage wiring per the diagram on the pump motor and replace the motor connection access plate. This is much easier to do on a bench than on the floor. 7
8 4.B PLUMBING THE PRESSURE BOOSTED SYSTEM (CONTINUED) 1 Position the Oxidizer Tank and Booster Pump as shown previous page. The system must be plumbed in after the well pump pressure tank and any raw waterline must tee into the line ahead of the Pump inlet. 2 Assemble the Air Inductor assembly as shown. Orient the pressure gauges so they can be read, but hand tight only. Inlet pressure gauge seals against an O-ring, however the system pressure gauge requires Teflon tape to seal. Install the Air Filter finger tight only as it may be removed later in the installation. Secure all union connections hand tight. 3 Glue the outlet port of the Air Inductor to the inlet of the Tank. If you are feeding solution with a chemical pump, plumb a tee in the line between the Air Inductor and the Tank inlet for the injector. Avoid feeding chemicals ahead of the Air Inductor, as it may lead to scaling and sacrifice the performance of the air Induction. 4 Make a pump discharge fitting as shown with a 1 union. Thread the fitting into the end or discharge of the Booster Pump as shown. 8
9 4.B PLUMBING THE PRESSURE BOOSTED SYSTEM (CONTINUED) 5 Glue the Air Inductor inlet fitting to the Booster Pump discharge fitting using 1 NPS pipe. If you wish to elevate the Booster or locate the Pump on the inlet side, then you can glue 1 NPS ell(s) to the discharge pipe and set the pump horizontally even at another location within 20 using as few ell as is practical. The control line provided is only 6 long. 6 Plumb the supply line from the well tank to the inlet (top) of the Booster with a union. Make certain that all raw waterlines tee from the supply before the Booster inlet. Set the well pump cutout pressure so that it is lower than the Booster cut-in pressure (55-75 PSI). 7 Install a drain valve on the Tank drain and plumb the drain line to the exterior or adequate drain. Plumb the pressure relief discharge to the exterior or an adequate drain. Plumb the relief valve discharge to the exterior or a suitable drain. Failure to do so can result in flooding and property damage. 8 Thread the ¼ Ell provided into the port on the pressure switch with Teflon tape finger tight. Loosen the compression nut then press one end of the ¼ tubing provided into the fitting so that the tubing is past the seal, then secure the nut finger tight. 9 Press the other end of the pressure control line onto the pressure control fitting on top of the Air Inductor outlet. 10 Connect to the vent line 3/8 polyethylene tubing (not provided) and run the length of tubing to the exterior. The air released from this line is humid and may corrode metal in the vicinity. Should the vent valve malfunction water can spray from the line. 11 Plumb the outlet of the Tank with a ball valve to the treated line or contact tank, if required. 12 When using a contact tank, install a drain valve on the Tank drain as done above in step 7 and plumb to the exterior or an adequate drain. Plumb the tank outlet as done in step 11 to the treated line or contact tank if additional contact is required. 9
10 5. WIRING THE PRESSURE BOOSTER All wiring and fuse sizing are preliminary recommendations only. For your safety, local codes and in their absence, national codes must be followed to minimize risk of electrical shock, property damage or personal injury. Grounding the pump is essential for your protection and the protection of the motor. All wiring should be completed by a trained electrician and or qualified professional. The voltage of the pump must match the voltage of the power source. The ½ hp booster pump is factory set for 115 Volts. To connect to 230 volts make certain the power source is disconnected then wire to the junction box. Change the motor voltage setting on the booster motor following the wiring diagram located below and on the motor label. The ¾ & larger hp booster pumps are factory preset for 230 volts. The power leads should be large enough to carry the rated amperage. 1 Remove the plastic cover from the pressure switch and the lock nut from the ½ connector to the motor. Place the switch on the connector secured to the motor and secure the switch horizontally with the lock nut. Remove the electrical access plate from the back of the motor. 2 Pass the two pressure switch wires through the connector as shown. 3 Attach one of the pressure switch wire leads to the Line # 1 push-on tab and then attach the other lead to the Line # 4 push-on tab on the motor terminal board. If changing the voltage move the other wires as indicated in the diagram below. Replace the motor access plate when wiring is complete. 4 Now wire the pressure switch placing the ground on the ground lug first then placing the lines or the line and common on the two outside lugs. Connect the wiring at the electrical source. Replace the cover when wiring is complete. Secure the wires with the lug nuts firmly as loose lugs cause arcing and subsequent heat damage and failure. 10
11 6. STARTUP & ADJUSTMENT 1 After completing the plumbing remove the inlet union nut to the Air Inductor or to the booster pump and separate the line so the line can be flushed out to a bucket or drain. Turn the well pump on momentarily to flush out any line debris. Then reconnect the union. Line debris can cause the Air Inductor or the booster pump to malfunction, always flush the lines prior to pressurizing. 2 Turn off any drain valves and the Oxidizer Tank outlet valve. Restore power to the well pump and pressurize the system. You will hear water rush through into the Tank and later hear air venting from the vent valve until water reaches the set level. If using a booster pump: Immediately turn on power to the pressure booster. After the system is pressurized check for leaks. Often some vibration will occur in the Air Inductor. This will diminish in an hour and completely disappear in days as air from the installation trapped in the bypass damper is adsorbed. 3 Adjust the pressure switch to the desired pressure PSI. It may be necessary to cycle the pump several times to achieve the proper setting. While filling the Tank and at cut-in the inlet pressure will be around 40 PSI greater. If not using a booster pump: The inlet pressure on the Air Inductor must be 20 PSI greater than the cut-out pressure setting on the Oxidizer Tank. The Air Inductor must draw air through the entire pump cycle. Air induction must be constant for thorough treatment. Check at this time that air is drawn when the system pump runs. Run the Oxidation Tank pressure as high as possible while still inducting air gives a longer pump cycle and higher oxygen levels for treatment. Never exceed the working pressure rating on the Tank. Higher pressure than rated can damage the unit; void the warrantee and cause flooding damage. 4 If using a contact tank to extend treatment capacity, fill the contact tank with the outlet valve off. Throttle the Oxidizer Tank outlet valve so pressure remains constant while filling the contact tank. Once pressurized open valve and vent the air displaced from the contact tank so it doesn t enter the home. Sulfur will be gone in the number of hours equal to the concentration of sulfide in PPM. (Example: 10 ppm H2S take 10 hours to remove). Waterlines require several day to clear up. Extremely caked lines require several weeks and line flushing to clear up completely. 11
12 7. TROUBLESHOOTING CHART 12
13 APPLICATION RECORDS AND NOTES 13
14 OXIDIZER LIMITED PRODUCT WARRANTEE This warrantee cannot be transferred- it is extended only to the original purchaser or first user of the product. By accepting and keeping this product you agree to all of the warranty terms and limitations of liability described below. Read carefully the installation, operation and maintenance instructions in this manual to avoid serious personal injury and or property damage and to ensure safe and effective use of the product. Aquatechnics warrants to the purchaser or first user of the new product that at the time of manufacture, the tank and component parts used with the product are free from defects and workmanship. Any warranty claim made must be made within (2) years unless another time period is set forth in this manual. Any warranty claim made on the pump must be made within (1) one year as is customary with pumps. In the event of a breach of the foregoing warranty Aquatechnics will, at it s discretion either make repairs or supply a new component or replacement part. Aquatechnics will not accept any claims for labor, property damage or other cost. This warranty does not cover any claim unless it was caused by a defect in material or workmanship during the warranty period. In addition this warranty does not apply: If the product is not correctly installed, operated, repaired or maintained as described in the manual; To any failure resulting from abuse (including freezing); improper or negligent: handling, shipping, storage, use, operation, accident; or alteration, lightning, flood or any other environmental condition; To any failure due to any use other than that specified in the manual. This Warranty does not cover any claims made to Aquatechnics or an authorized distributor or retailer more than 30 days after expiration of the applicable time period. This warranty also does not cover repair or replacement cost not authorized in advance by Aquatechnics. Aquatechnics must authorize any covered warranty service. Contact the person from whom you purchased the Product, who must receive authorization from an Aquatechnics distributor or Aquatechnics. If you do not receive a prompt response, contact Aquatechnics directly at the address below. Before Aquatechnics determines to provide any replacement part or component, it may as a precondition require that warranty claimant ship the product, postage prepaid to an authorized Aquatechnics representative, or to Aquatechnics and provide proof of purchase evidenced by the original sales receipt or product registration. In the case of replacement Aquatechnics reserves the right to make changes to the design, material, construction or to substitute components or products, which shall be subject to all of the terms and limitations of this warranty, except that the applicable warranty periods shall be reduced by the amount of time the warranty claimant owned the product prior to submitting notification of the warranty claim W UNIVERSITY BLVD JACKSONVILLE, FL INFO@AQUATECHNICS.BIZ PRODUCT MODELS DURATION ODOR OXIDIZER ALL MODELS TWO (2) YEARS LIMITED WARRANTEE BOOSTER PUMP ALL MODELS ONE (1) YEAR LIMITED WARRANTEE 05/15/2008 AQUATECHNICS MANUFACTURING INC 14
SYSTEMS for CATALYTIC FILTERS
OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION
More informationSTOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.
STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts
More informationAer-Max Installation Instructions
Aer-Max Installation Instructions Congratulations on selecting this quality Aer-Max system. Important: Please read all instructions before assembling and installing the Aer-Max system. Consult local plumbing
More informationispring Whole House Water Filter Systems USER S MANUAL
ispring Whole House Water Filter Systems USER S MANUAL Version 2014-5 Introduction Congratulations on your purchase of the ispring Whole House Water Filter system. Featuring a three-stage filtration process,
More informationIMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS 2 1. Read and Follow All Instructions 2. Read this manual completely before attempting installation. 3. All permanent electrical connections should be made by a qualified
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationInstallation Instructions PP-AS20 Anti-Scale System
Installation Instructions PP-AS20 Anti-Scale System THIS UNIT MUST BE INSTALLED BY A LICENSED PLUMBER TO VALIDATE THE WARRANTY. COMPONENTS PP-AS20 Filter Housing PP-AS20R Filter Cartridge Installation
More informationHALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps
Safety Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this
More informationModel NFF Iron, Manganese, Hydrogen Sulfide Reduction
Super Filter Model NFF Iron, Manganese, Hydrogen Sulfide Reduction Operating and Maintenance Manual Page 1 of this manual contains operating conditions. 57055 9/07 Enjoy clean, stain-free laundry and dishes...
More informationINSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK
INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK FOR USE WITH 1 CU. FT. AUTOMATIC BACKWASHING FILTERS 7-LAER1047-115 AERATION SYSTEM 7-LAER1047-230
More informationSPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax
SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts
More informationMIGHTY PRO 1/4 HP CHILLER
1 MIGHTY PRO 1/4 HP CHILLER FOR TANKS UP TO 170 GALLONS TOP QUALITY & HIGHLY EFFICIENT INTEGRATED DUAL STAGE THERMOSTAT 2 ASSEMBLY PARTS FRONT TOP VIEW BACK 3 SET UP INSTRUCTIONS 1. Remove chiller and
More informationKinetico 2060f OD Sulfur Guard Installation Instructions
SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.
More informationFleck 2510 SXT Catalox Installation & Start Up Guide
Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationIMPORTANT SAFETY INFORMATION READ ALL...
INSTALLATION and SERVICE MANUAL HOUSEPURE MODELS HP03 and HP04 736-0137 Table of Contents IMPORTANT SAFETY INFORMATION READ ALL... 3 P/N 41482 Rev A 06/04 INSTRUCTIONS BEFORE USING... 3 FEEDWATER... 4
More informationSEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL
SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL This manual is provided as a guide to installation. All installations must comply with any and all local and national electrical
More informationWM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis
WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com
More informationInstallation and Operating Instructions
Installation and Operating Instructions WaterQuick Pro II Advanced - Hot Water Circulation Pump WaterQuick Pro II Advanced Step 1. Choose the appropriate place to install the pump and Flow Monitor: WaterQuick
More informationINSTRUCTION MANUAL HS-229G
INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be
More informationDISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:
DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationJ120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D
INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW
More informationOzone + UV Sanitation
Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW
More informationOwner s Manual. Terpene Trap CF 1000
Owner s Manual Terpene Trap CF 1000 IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to use your Terpene Trap. For your safety, comply with all safety instructions and
More informationTRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999
TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO. 8801469 EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999 THE MILK COOLING SYSTEMS SPECIALISTS TM FRE-HEATER Part No. 8801469 Table
More informationNOTICE TO INSTALLER: Instructions must remain with installation. FW Supersedes HomeGuard OPTIMA
NOTICE TO INSTALLER: Instructions must remain with installation. FW1379 1018 Supersedes 0615 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies
More informationAlkaline RO System INSTALLATION MANUAL
Alkaline RO System INSTALLATION MANUAL 1-800-992-8876 Customer Support Disclaimer All rights reserved. All material published on this site by Express Water Inc., including all portions of the website,
More informationIsolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual
500 Point Breeze Rd. Flemington, NJ 08822 (908) 782-5800 Phone (908) 782-3380 FAX www.zrpure.com Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual - 1 Contents 1.
More informationA2Z Ozone, Inc. PRODUCT MANUAL
A2Z Ozone, Inc. PRODUCT MANUAL INSTALLATION & OPERATION MANUAL CE www.a2zozone.com Rev. 02142018 CONTENTS Page Important Safety Instructions... Specifications... Installation Instructions... 3 4 5 Troubleshooting...
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationProfessional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2
Professional Series Chemical Feed System Model # 22152-02 US Patent No. 6,752,930 B2 Product Manual SureWater Technologies, Inc. The Solution X-2 Model # 22152-02 Table of Contents 1. Installation Instruction
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water Copyright 2013 Prozone Water Products: 3004 11 th Ave. -
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationGenesis Whole House Chlorination System Page 2
Genesis Whole House Chlorination System Page 2 Genesis Whole House Chlorination System Page 3 Table of Contents Performance Data and System Specifications................................ 4 Unpacking and
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationMP-MBA-45T-1/60T-1 / 75T-1
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-45T-1/60T-1 / 75T-1 with the 268/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description
More informationGetz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED
More informationResidential Gas Hybrid Water Heater
Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse
More informationMASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech February 2010 Table of Contents Page No. Topic Description
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against
More informationSOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual
SOLARHOT SuperVox Installation/ Owner s Manual Description / Applications System Overview The SOLARHOT SuperVox solar thermal glycol system. The SuperVox allows for easy installation of large solar water
More informationOPERATING AND INSTALLATION MANUAL
OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against
More informationINSTALLATION INSTRUCTIONS WARRANTY
QT FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. Low Head Pump Center Flow Chart Fig. 2. High Head Pump Center Flow Chart NOTE: Read the entire instruction manual before starting the installation. WARRANTY
More informationInstallation & Service Manual
Installation & Service Manual Table of Contents Unpacking & Inspection... 2 Basic Guidelines... 2 Specifications... 3 Before Starting Installation Where to install the filter... 4 Tools, pipe, fittings
More informationHardwired Electric Garage Heater
Hardwired Electric Garage Heater G73 OWNERS MANUAL v1.0 Read and save these instructions. Manual v1.1 2 A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus
More informationTIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL
TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6
More information7500-S Sediment Backwash Filter Guide
Clean Water Made Easy. www.cleanwaterstore.com 7500-S Sediment Backwash Filter Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system
More informationUSER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY
USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY THIS UNIT IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT UNI-RAM CORPORATION ONTARIO CANADA REV 2010-09 CONTENTS
More informationOZONE SYSTEM FOR IN-GROUND POOLS New and Existing
INSTALLATION & OPERATIONS MANUAL FOR Z0-910/912 OZONE SYSTEM FOR IN-GROUND POOLS New and Existing MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0454-041900/03 IMPORTANT SAFETY
More informationUser Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)
User Manual AIR HOG Model: 7303L Vacuum Booster REV. 3/20/18 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 INTRODUCTION Dear Customer: Congratulations on the purchase of your new
More informationUse & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
More informationMixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50
INSTALLATION MANUAL for MDV Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50 MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0635
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationBEFORE OPERATING THE MACHINE: WARNING
BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this
More informationMKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual
MKTF - 215 CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual Please fill out the following information at the time of installation. Save for future reference. Model: Date Code:
More informationElectric Garage Heater
Electric Garage Heater G73 OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2 From the
More informationInstallation and Operation Manual. ACF-18 Automatic Chlorinating Feeder
Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum
More informationOwner s Manual Refrigerated Compressed Air Dryers Model F-100
Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
More informationArch Feeder: Installation Manual
Arch Feeder: Installation Manual Model #A300N Arch Chemicals, Inc. 1200 Lower River Road, P.O. Box 800 Charleston, TN 37310-0800 Product Stewardship MAKING THE WORLD A BETTER PLACE Arch is committed to
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationInstallation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324
Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324 To prevent accidents, which could cause serious injury or death, as well as machine damage read these instructions before installation
More informationMCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA
MCD Corona Discharge Ozone Generators MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 4-0622 Copyright 2005 DEL Ozone, Inc. IMPORTANT SAFETY INSTRUCTIONS When installing and using DEL Models
More information2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP
2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID
More informationJ-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide
J-PRO-22 110V 230V Dual Voltage Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air
More information52 CEILING FAN. Owner s Manual Models #50336, 50337
52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.
More informationHardwired Electric Garage Heater
Hardwired Electric Garage Heater G73 OWNERS MANUAL Read and save these instructions. 2 Trust has to be earned, and we will earn yours. Customer happiness is the focus of our business. From the factory
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS VARIABLE SPEED BOOSTER PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION WARNING: RISK OF ELECTRICAL SHOCK
More informationTankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRT**150 / WGRT**199 / WGRTC**199 **A suffix of LP denotes propane gas **A suffix of NG denotes natural gas NOTICE: Westinghouse reserves the right
More informationgamma pond Ultraviolet Sterilizers
gamma pond Ultraviolet Sterilizers Instructions for Models #1410 8w, 1411 15w, 1412 25w, 1403-40w Important Safety Instructions... Page 2 Installation... Page 3 Maintenance & Winterizing... Page 5 Warranty...
More informationCSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models
ASME CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models RETAIN THIS OPERATING MANUAL WITH BOILER. DO NOT DISCARD READ THIS FIRST: The safeguards and instructions
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationQUICK PRIME INSTALLATION AND SERVICE MANUAL
QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #
More informationInstallation Instructions AS-WH Whole House Water Filter
Installation Instructions AS-WH Whole House Water Filter Contents The AS-WH Whole House System is tested to NSF standards to reduce 97% of chlorine. It can also reduce sediment, synthetic chemicals and
More informationForm 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM
0 Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC Installation and Operating Service Manual BOILER FEED SYSTEM INSTALLATION AND OPERATION SERVICE MANUAL BOILER FEED SYSTEM Bryan Steam LLC 783 North
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532
Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationDuct Mount Atomizing Humidifier
Duct Mount Atomizing Mister 50 (24V) Mister 50-1 (120V) Manual for: Installation Operation Maintenance CAUTION: Read installation, operation, and maintenance instructions carefully for safe operation.
More informationInstallation and Maintenance Guide
Installation and Maintenance Guide Inline Chlorinator TM Vitasalus is a trademark owned by Vitasalus, Inc. Vitasalus, Inc. 248-585-8815 1409-H Allen Drive. Troy, Michigan 48083 USA www.vitasalus.com Table
More informationINSTALLATION INSTRUCTIONS
Items Included in System: Polar White Part # s 301-032-00002 301-032-00006 301-032-00011 Black Part # s 301-032-00003 301-032-00005 Atmospheric Vacuum Breaker/Check Valve Part #571 VAC CHK Spin Weld Spray
More informationPrime chiller. Inline Chiller. Instructions for Models #2645,2646
Prime chiller Inline Chiller Instructions for Models #2645,2646 Warning and Safety Instructions... Page 2 Chiller Installation... Page 3 Temperature Controller Programming... Page 5 Warranty... Page 7
More informationOPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS
Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water PROZONE Copyright 2018 Prozone Water Products: 3004 11 th
More informationINSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed.
More informationDR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR
DR Series HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR Model: DR-10 Installation & Operations Manual 451 Black Forest Road, Hull, Iowa, 51239 712.439.6880 info@ozonesolutions.com www.ozonesolutions.com
More informationOwner s Manual Refrigerated Compressed Air Dryer Model F-50
Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all
More informationQUICK PRIME INSTALLATION AND SERVICE MANUAL
QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #
More information2-Stage Under Counter Filtration System Model: WP-2 LCV
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference 2-Stage Under Counter Filtration System Model: WP-2 LCV IMPORTANT If you are unsure about installing your WATTS water filter,
More informationWhole House Descaler Installation Instructions
Whole House Descaler Installation Instructions MODEL HF-SOFT Safe, effective scale prevention without the use of chemicals or salt. HF-SOFT DIRECTION OF FLOW 26" Shut-Off Valve 48" 5-Micron Pre-Filter
More informationACT Cartridge Dust Collector
IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions
More informationInstallation Manual & Owner s Guide
Installation Manual & Owner s Guide Table of Contents Benefits of Iron Shield +... 1 How Iron Shield + Works... 2 Unpacking & Inspection... 3 Basic Guidelines... 3 Specifications... 4 Regeneration Schedules...
More information18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.
18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler. File this owner s manual in a safe place for future reference. It contains operating
More informationWILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS
INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting
More informationAMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762
AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation 4151 112 th Terrace North Clearwater, Florida 33762 COMMERCIAL REFRIGERANT DESUPERHEATER WASTE HEAT RECOVERY INSTALLATION/OPERATION/MAINTENANCE
More informationParts and Service Manual BURNISHER MODEL: MR , MR , MR , MR
Parts and Service Manual BURNISHER MODEL: MR2000-115, MR1500-115, MR2000-220, MR1500-220 TABLE OF CONTENTS RECEIVING YOUR EQUIPMENT... 3 WARNINGS AND SAFETY... 3 ELECTRICAL INFORMATION... 4 GROUNDING INSTRUCTIONS...
More informationHOMEADVANTAGE II IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL HOMEADVANTAGE II HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical
More informationINSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC
INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump
More information