Installation and Operation

Size: px
Start display at page:

Download "Installation and Operation"

Transcription

1 Vane Axial Fan Installation and Operation Model #: Owner s Manual PNEG-010 Date: PNEG-010

2 Fan Check List 1. All wire connections. 2. Tip clearance on blade. 3. Fan blade torqued to torque specs. 4. Grill guard in place and tight. 5. Fuse in place, extra fuse provided. 6. Motor rotation correct. 7. Contactor engages properly. 8. Running amperage. 9. Vibration. 10. All fasteners tight. 11. Indicator light. 12. All decals and serial number tag. 13. Aesthetic appearance. 14. Manual. Tester Signature: Date: Record in the space provided below the Model # and Serial # of this product. These numbers are found on the Model and Serial Tags located on the outside of the unit. Model #: Serial #: Keep these numbers for future reference. 2 PNEG-010 Vane Axial Fan

3 Table of Contents Contents Chapter 1 Safety...4 Safety Guidelines... 4 Safety Instructions... 5 Chapter 2 Decals...7 Roof Damage Warning and Disclaimer... 7 Safety Alert Decals... 8 Chapter 3 Installation Instructions...10 Vane Axial Fan Pad Chapter 4 Fan Installation...11 Pre-Installation Requirements Machine to Earth Ground Previously Installed Units Proper Installation of the Ground Rod Chapter 5 Fan Specifications...15 Chapter 6 Fan Operation...18 Fan Start-Up Fan Shut Down Maintaining Grain Quality Grain Storage Fan Blade Removal and Installation Removing the Fan Blade Assembly Installing the Fan Blade Assembly Chapter 7 Fan Service...24 Fan Blade Inspection and Maintenance Fan Motor Chapter 8 User Servicing Instructions and Troubleshooting...27 Fan Troubleshooting Flow Chart Chapter 9 Parts List ''-14'' Fan Parts ''-28'' Fan Parts Chapter 10 Wiring Diagrams Phase 230 Volt Schematic Phase 230 Volt Wiring Diagram and Parts Phase 230 Volt Schematic Phase 230 Volt Wiring Diagram and Parts Phase 460 Volt Schematic Phase 460 Volt Wiring Diagram and Parts Phase 575 Volt Schematic Phase 575 Volt Wiring Diagram and Parts Chapter 11 Warranty...41 PNEG-010 Vane Axial Fan 3

4 1. Safety Safety Guidelines This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections. Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER WARNING CAUTION NOTICE DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to personal injury. 4 PNEG-010 Vane Axial Fan

5 1. Safety Safety Instructions Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel. As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel. Avoid any alterations to the equipment. Such alterations may produce a very dangerous situation where SERIOUS INJURY or DEATH may occur. This equipment shall be installed in accordance with the current installation codes and applicable regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine. Keep signs in good condition. Replace missing or damaged safety signs. Be sure new equipment components and repair parts include the current safety signs. Replacement safety signs are available from the manufacturer. Learn how to operate the machine and how to use controls properly. Do not let anyone operate without instruction. Keep your machinery in proper working condition. Unauthorized modifications to the machine may impair the function and/or safety and affect machine life. If you do not understand any part of this manual or need assistance, contact your dealer. Read and Understand Manual Install and Operate Gas-Fired Equipment Properly Fuel supply should be installed by a qualified gas technician and must meet local and state codes for gaseous fuel supplies. Disconnect and lock out all fuel sources before servicing equipment. Explosive Gases PNEG-010 Vane Axial Fan 5

6 1. Safety Install and Operate Electrical Equipment Properly Electrical controls should be installed by a qualified electrician and must meet the standards set by the National Electrical Code and all local and state codes. Disconnect and lock out all power sources before installing wires/cables or servicing equipment. Electric Shock Hazard Prepare for Emergencies Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service, hospital, and fire department near your telephone. Keep Emergency Equipment Quickly Accessible Wear Protective Clothing Wear close-fitting clothing and safety equipment appropriate to the job. Eye Protection Remove all jewelry. Tie long hair up and back. Gloves Wear safety glasses at all times to protect eyes from debris. Wear gloves to protect your hands from sharp edges on plastic or steel parts. Wear steel-toed boots to help protect your feet from falling debris. Tuck in any loose or dangling shoestrings. Steel-Toed Boots Respirator A respirator may be needed to prevent breathing potentially toxic fumes and dust. Wear a hard hat to help protect your head. Wear appropriate fall protection equipment when working at elevations greater than six feet (6'). Hard Hat Fall Protection 6 PNEG-010 Vane Axial Fan

7 2. Decals Roof Damage Warning and Disclaimer The manufacturer does not warrant any roof damage caused by excessive vacuum or internal pressure from fans or other air moving systems. Adequate ventilation and/or makeup air devices should be provided for all powered air handling systems. The manufacturer does not recommend the use of downward flow systems (suction). Severe roof damage can result from any blockage of air passages. Running fans during high humidity/cold weather conditions can cause air exhaust or intake ports to freeze. CAUTION Excessive vacuum (or pressure) may damage roof. Use positive aeration system. Make sure all roof vents are open and unobstructed. Start roof fans when supply fans are started. Do not operate when conditions exist that may cause roof vent icing. GSI Group, Inc DC-969 PNEG-010 Vane Axial Fan 7

8 2. Decals Safety Alert Decals WARNING GSI Group Stay clear of rotating blade. Blade could start automatically. Can cause serious injury. Disconnect power before servicing. DC-1225 DC PNEG-010 Vane Axial Fan

9 2. Decals GSI Group Inc DANGER HIGH VOLTAGE Will cause injury or death. Lockout power before servicing. DC-889 PNEG-010 Vane Axial Fan 9

10 3. Installation Instructions Vane Axial Fan Pad Placement of the Fan Pad: Transitions/Fans/Heaters Only If a fan or fan and heater is to be installed, refer to Figure 3A to determine the concrete pad size. 1. The top of this pad should be level with the top of the bin s foundation. 2. Recommended pad thickness is 4" minimum. 3. Front of pad should be perpendicular to bin wall. 4. Pad for heater not required, but if it is to added, pour the pad to cover both locations. For fans and transitions used in aeration duct system applications, refer the transition and aeration installation instructions. IMPORTANT: Fan pad and fan must be level and smooth for proper operation. Vibration problems can result from improper fan leveling. TR-4734 A = 20" for fans without heaters A = 44'' for fans with heaters TR-6918 and TR-6919 A = 32" for fans without heaters A = 56" for fans with heaters TR-7048 A = 45" for fans without heaters A = 69" for fans with heaters Figure 3A 10 PNEG-010 Vane Axial Fan

11 4. Fan Installation Pre-Installation Requirements Foundation Use the dimension Figure 5A on Page 15 in the specifications section of this manual to determine the physical size of the fan to be installed. Use the dimensions shown to determine the position of the fan installation with respect to other equipment. For proper operation of the fan, the unit is to be mounted on a level pad. The fan should not be anchored to the pad, but it should be allowed to float on the pad. Refer to Figure 5A on Page 15 for fan pad location in the specifications section of this manual for recommendations of pad placement with respect to various catalog transition ducts. Transition The transition duct should be all metal construction, with a gradual angle to the rectangular opening in the bin wall. The duct should allow for a smooth transition with minimal resistance of the airflow from the fan discharge to the bin plenum. Keep the entrance of the plenum as clear as possible from obstructions by floor support. Roof Exhaust Adequate exhaust air openings in the roof are required to prevent any additional back pressure from building in the bin. See roof damage warning and disclaimer on Page 7. Power Supply Adequate power must be supplied to the fan for reliable operation. Consult the local power company and have a representative survey the installation. Only the power company can ensure that their system is sized properly to provide adequate service to the installation and new equipment. Wire Size Undersized wire can lead to voltage drop which causes motor overheating and shortened motor life. Use the electrical specifications chart on Page 16 in this manual to size the supply wire according to the horsepower of the fan and the distance to the power supply. Refer to fan specifications section on Page 15 of this manual to find the full load current of the motor for a given fan size. The full load current can also be found on the motor nameplate. Service Disconnect Each fan motor must be supplied with an independent power circuit, equipped with a fused disconnect switch. Locate this switch near the unit, as the power should be shut off before servicing the fan. It is the customer s responsibility to provide a fused disconnect and motor overload protection. These must be properly sized and connected to allow proper motor operation. Failure to provide these components could cause severe motor damage and void the manufacturer s warranty. PNEG-010 Vane Axial Fan 11

12 4. Fan Installation Fan Installation 1. Remove packaging materials and inspect fan for any shipping damages. Report these at once to the shipper. 2. Check all fasteners on the fan to make sure they are tight (fasteners may loosen during shipment). Tighten any loose fasteners, check for proper clearance and re-tighten. 3. Check all electrical connections that may have loosened during shipment. 4. Rotate the fan blade. Blade should rotate freely and should not make contact with the housing sides or venturi. 5. Place fan in proper location on the fan pad. Attach fan to transition duct and seal connection with caulk. 6. Check all joints and seams around the lower part of the bin. Verify that these are well sealed to prevent air leakage from the bin plenum. Inspect the transition duct as well. Seal any leaks that may be present to prevent air losses that reduce fan efficiency. 7. Level fan. Fan pad should be poured flat and level, however, it may be necessary to shim the legs provided on the fan housing to level the fan. Fans not resting on support legs may have excess vibration which can lead to premature wear and tear on fan components. DANGER Always disconnect and lock out power before working on or around fan. IMPORTANT: Electrical installation must be performed by a qualified electrician, in accordance with National and Local Electrical Codes. Any violation of electrical wiring codes could jeopardize the warranty. Electrical Installation 1. Verify that the incoming power supply has been deemed adequate by the local power company. 2. Verify that the wiring supplying power to the fan is sized correctly for the distance away from supply and fan horsepower. (See tables in specification section on Page 16 of this manual.) 3. Verify that the safety disconnect is installed and sized correctly for the fan size. (See tables in specification section on Page 16 of this manual.) 4. Install a machine to earth ground for each individual fan. Refer to ground rod installation on Page 14 in this manual. 5. The following wires must be supplied to each fan. Units without control transformers require a separate neutral and earth ground connection. 1 PH 230V L1, L2, N, G 3 PH 230V L1, L2, L3, N, G 3 PH 230V with optional transformer kit L1, L2, L3, G 3 PH 460V/575V L1, L2, L3, G 6. The starter controls require 115 VAC power to operate. On 230 volt 3 phase units, this power is supplied by L1 to neutral. 12 PNEG-010 Vane Axial Fan

13 4. Fan Installation CAUTION The voltage between L1 and N must be 115 VAC. Any other voltage will cause damage to equipment. Check this voltage before starting unit. If voltage is not within 105 VAC-125 VAC, check for proper voltage on L2 or L3 and move to appropriate leg. If voltage is not acceptable, install a 1/4 KVA step-down transformer. (NOTE: Grounded B and some open delta power supplies will require this transformer kit.) Final Check Check to make sure all safety guards are in place and not damaged. Replace damaged parts. Check to make sure all decals are visible and not damaged. Replace damaged decals. Check to make sure all control boxes are closed and no wiring is exposed. Test Run When the fan is completely installed, the unit will need to be checked for proper rotation. Provide power to the fan controls and start the fan momentarily. Make sure that the fan blade rotation is in the direction that the decal on the fan housing illustrates. If the blade is rotating the wrong direction, have the electrician correct the wiring. Use a #6 or approved size bare copper ground wire. Install a 5/8" diameter 8' long copper-clad ground rod, 2' away from the foundation and 1' below the surface of the ground or in accordance with local requirements. Figure 4A PNEG-010 Vane Axial Fan 13

14 4. Fan Installation Machine to Earth Ground It is very important that a machine to earth ground rod be installed at the fan. This is true even if there is a ground at the pole 15' away. This ground needs to be as close to the fan as possible, but no more than 8' away. The ground rod should be connected to the fan control panel with at least a #6 solid bare copper ground wire or in accordance with local requirements. The machine to earth ground provides additional safety if there is a short. It also provides the grounding necessary for long life and operation of the solid state circuit boards used on control circuits and the electronic ignition systems. Previously Installed Units It is recommended that previously installed units be checked to see that a machine to earth ground has been installed by an electrician. Proper Installation of the Ground Rod Ground rods and wires are not supplied. It is recommended that the rod not be driven into dry ground. The following steps ensure proper ground rod installation: 1. Dig a hole large enough to hold 1 to 2 gallons of water. 2. Fill hole with water. 3. Insert rod through water and jab it into the ground. 4. Continue jabbing the rod up and down, the water will work its way down the hole, making it possible to work the rod completely into the ground. This method of installing the rod gives a good conductive bond with the surrounding soil. 5. Connect the bare copper ground wire to the rod with the proper ground rod clamp. 6. Connect the bare ground wire to the fan control boxes with a grounding lug. 7. Ground wire must not have any breaks or splices. Insulated wire is not recommended for grounding. Dig a hole large enough to hold 1 or 2 gallons of water. Work the ground rod into the earth until it is completely in the ground. Figure 4B 14 PNEG-010 Vane Axial Fan

15 5. Fan Specifications Fan 12'' Diameter 1 HP 12'' Diameter 0.75 HP 14'' Diameter 18'' Diameter 1.5 HP/3 HP 24'' Diameter 26'' Diameter 28'' Diameter A (Bolt circle) 13-1/2" 13" 15-1/4" 19-1/4" 25-3/4" 27-3/4" 30" B (Inside diameter) 12-1/4" 11-7/8" 14-1/4" 18-1/4" 24-1/4" 26-5/16" 28-1/4" C (CL to bottom of leg) 7-9/16" 7-9/16" 10-7/8" 11-7/8" 15-7/16" 16-7/8" 18-1/8" D (Length) 16-1/8" 16-1/8" 16-3/16" 17/20" 24" 24" 24" E /4" /4" NOTE: All dimensions in inches. Figure 5A Fan Dimensions PNEG-010 Vane Axial Fan 15

16 5. Fan Specifications Fan Electrical Specifications Fan Horsepower 3/4 1 RPM Phase Volts Full Load Amps Minimum Wire Size Copper Wire Copper Wire 50' Run ' Run ' Run ' Run Minimum Wire Size Aluminum Wire Aluminum Wire 50' Run ' Run ' Run ' Run Fuse Size (Slow Blow) Breaker Size Fan Horsepower 1-1/2 3 RPM Phase Volts Full Load Amps Minimum Wire Size Copper Wire Copper Wire 50' Run ' Run ' Run ' Run Minimum Wire Size Aluminum Wire Aluminum Wire 50' Run ' Run ' Run ' Run Fuse Size (Slow Blow) Breaker Size PNEG-010 Vane Axial Fan

17 5. Fan Specifications Fan Horsepower 5 7 RPM Phase Volts Full Load Amps Minimum Wire Size Copper Wire Copper Wire 50' Run ' Run ' Run ' Run Minimum Wire Size Aluminum Wire Aluminum Wire 50' Run ' Run ' Run ' Run Fuse Size (Slow Blow) Breaker Size Fan Horsepower RPM Phase Volts Full Load Amps Minimum Wire Size Copper Wire Copper Wire 50' Run ' Run ' Run ' Run Minimum Wire Size Aluminum Wire Aluminum Wire 50' Run ' Run ' Run ' Run Fuse Size (Slow Blow) Breaker Size PNEG-010 Vane Axial Fan 17

18 6. Fan Operation After initial installation and also prior to using the unit each season, check the operation to ensure proper functioning, adjustment and reliability. Fan Start-Up 1. Make certain the unit is properly installed and connected, as described within the installation section of this manual. All air passage joints and seams must be well sealed. 2. With main power supply turned OFF, rotate the blade by hand to make certain it turns freely without contacting the housing or venturi. 3. Open roof doors to allow airflow at all times when fan is operating. IMPORTANT: Refer to roof damage disclaimer in the safety section on Page 7 of this manual. 4. Turn ON main power disconnect switch. WARNING Make certain all guards and covers are securely in place. 5. Press the fan Start button and check the following: a. Check direction of blade rotation. Correct if needed by following the instructions on the motor. b. Check to make sure the blade comes to full operating speed in less than 10 seconds. If there is any doubt as to proper operation, check the current draw of the motor. The motor amperage should not exceed the maximum full load amps listed on the motor nameplate. Fan Shut Down 1. Press the fan Stop button on units equipped with motor controls. 2. Shut off electrical power at main and at disconnect. 3. Close the roof openings and cover fan inlet to prevent harmful back-draft air currents from passing through the grain and to avoid grain infestation from rodents and insects. Maintaining Grain Quality To properly maintain the quality of stored grain, it is necessary to keep the grain dry, cool and insect free. Any one of these problems can contribute to spoilage. Wet, warm grain promotes insect growth as well as grain spoilage. Cool, dry grain can keep for long periods of time. (See Chart on Page 19.) It is recommended that the grain be kept cool (avoid freezing as freezing can reduce quality). Grain should be cooled through the fall and winter, warmed in the spring and summer. 18 PNEG-010 Vane Axial Fan

19 6. Fan Operation Grain Storage IMPORTANT: Conditions and requirements may vary from area to area. Contact the local agriculture extension office or state agriculture university for more exact guidelines. Average grain temperature should be above 35 F in the winter and below 65 F in the summer. Always try to keep the grain within 10 F-15 F of the average monthly outside temperature. This means grain may need to be aerated on warm days during the winter to stay above 35 F when freezing temperatures are predominate. During the summer it may be necessary to aerate the grain on cool nights, so the 65 F temperature is not exceeded during the hot days of summer. If the grain is to be stored more than 1 year, it has to be recooled the following fall and winter, repeating the process as long as the grain is in storage. Frequent and regular inspection (at least weekly during fall and spring) is the best prevention against grain spoilage. Equilibrium Moisture Chart Air Temperature Percentage Relative Humidity F F F F F F F Safe moisture for normal winter storage of shelled corn is about 15%. Grain to be stored through the summer or long term, needs to be 1 to 3 points dryer. Approximate Allowable Holding Time for Field-Shelled Corn, to Maintain Grade* Grain Temperature 15% Days 18% Days 20% Days 22% Days 24% Days 26% Days 28% Days 30% Days 40 F F F F F *Allowable holding time for field-shelled corn at various grain temperatures and moisture. PNEG-010 Vane Axial Fan 19

20 6. Fan Operation Approximate Hours of Fan Time to Change Bin Temperature Fan Size HP Bin Diameter Approximate 22' to Eave-Approximate Hours of Fan Time Required Approximate 32' to Eave NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR Approximate BU Bushels are rounded and approximate. NR 2. The hours required are based on clean grain. High moisture grain and grain containing fines or foreign material will require more time to complete the air change. 3. Not Recommended: Bins in the NR range, may require fan(s) of a different size to get the cool time into the accepted range. 4. Bins requiring more than 100 hours of aeration to totally change the temperature may require continuous aeration at about 1/10 th CFM per bushel or some other acceptable method. Fan Blade Removal and Installation DANGER Always disconnect and lock out power before working on or around fan. The fan blade is secured to the motor shaft by the use of a taper-lock bushing, motor shaft key and cap screws. The size, quantity and torque of cap screws required will depend on the model of the fan. CAUTION Although the taper-lock method of retaining the blade onto the motor shaft is very simple and obvious, it is essential that the following points be read carefully and fully understood, as improper installation can result in serious or fatal injury caused by a loose, fast flying blade. THREADED BUSHING HOLES: The threaded holes within the bushing are provided for disassembly purposes only. Do not attempt to use these holes for re-assembly, as they will not allow the parts to become locked onto the shaft, thereby causing an extremely hazardous operating condition. CLEARANCE HOLES: When re-assembling parts, the cap screws must be installed through the UNTAPPED CLEARANCE HOLES to cause the blade to be pulled forward onto the tapered bushing, thus locking the parts securely onto the motor shaft. Refer to Page 23 (under installation section) for assembly details. 20 PNEG-010 Vane Axial Fan

21 Removing the Fan Blade Assembly 6. Fan Operation 1. Lock out and tagout the main power to make sure the dryer cannot be started during servicing. 2. Remove the grill guard. 3. If there is a safety washer present, remove the bolt, lock washer and safety washer. 4. Remove the bolts from the unthreaded holes of the bushing. Do not use these bolts for bushing removal. 5. Using an allen wrench, undo the set screw (if present) and remove the key from the keyway. 6. Install grade 5 or stronger bolts into the threaded holes in the bushing and gradually apply torque to each bolt to loosen the bushing. 7. Remove the bushing and fan blade assembly. Installing the Fan Blade Assembly 1. Clean the motor shaft, key, bushing and the bore of the hub with a non-residual cleaner, such as brake parts cleaner or electric parts cleaner. It is important that these mating surfaces be clean and dry and no grease or oil is present. The parts must be assembled dry for maximum friction. CAUTION Do not use any lubricant or thread locking compound during installation. The use of such products will cause improper bolt torque and will crack the fan hub. 2. Insert bolts into bushing holes and ensure the shoulder portion of the bolt is NOT protruding the hole. 3. Install the fan blade assembly onto the motor shaft. 4. Align the keyway in the bushing with the key and slide the bushing onto the motor shaft. NOTE: Do not use excessive force to drive the bushing onto the shaft. 5. Align bushing and hub keyways with the key. Bushing should be flush with the end of the motor shaft. 6. Loosely install the bolts through the unthreaded holes in the bushing into the threaded holes of the hub. 7. Find the applicable torque for the bushing in the chart on Page 22. The bushing type is etched into the face of the bushing. 8. Torque the bushing gradually to evenly seat it inside the hub and onto the motor shaft. Set the torque wrench to 1/3 of the required torque setting and tighten each bolt in a circular pattern three (3) times. Increase the torque setting on the wrench to 2/3 of the required torque and tighten each bolt in a circular pattern three (3) times. Increase the setting on the torque wrench to the final required torque setting and tighten each bolt in a circular pattern three (3) times. 9. If there is a safety washer present, install the washer, lock washer and bolt. 10. Turn the fan blade assembly by hand to make sure there is freedom of movement and uniform clearance around the inlet. 11. Install the grill guard and turn ON the main power source. PNEG-010 Vane Axial Fan 21

22 6. Fan Operation Installing the Fan Blade Assembly (Continued) 12. Operate the fan for 30 minutes. 13. Stop the fan and lock out and tagout the main power to make sure the dryer cannot be started during servicing. 14. Remove the grill guard and re-tighten the bolts in a circular pattern one time at the final required torque setting. 15. Install the grill guard and turn ON the main power source. Figure 6A Vane Axial Fan CAUTION Do not exceed the torque specifications listed on the bushing bolt torque chart. Exceeding the recommended torque will crack the fan hub. Bushing Bolt Thread Bolt Torque Foot - Pounds Bushing Bolt Thread Bolt Torque Foot - Pounds JA P-1 5/16" G 1/4"-20 6 SK 5/16" H 1/4"-20 6 SF 3/8" SH 1/4"-20 8 Q-1 3/8" SD 1/4"-20 9 R-1 3/8" SDS 1/4" PNEG-010 Vane Axial Fan

23 6. Fan Operation Installing the Fan Blade Assembly (Continued) Figure 6B Cutaway Drawing of Typical Propeller Installation Figure 6C Cap Screw Arrangement for Disassembly Cap screws installed through clearance holes of bushing. (See text on Page 22 for proper torque.) Figure 6D Cap Screw Arrangement for Resassembly PNEG-010 Vane Axial Fan 23

24 7. Fan Service Fan Blade Inspection and Maintenance Pre-season inspections should be done on the fan blade to look for the following: 1. Any debris (stalks, bees wings, mud, insects and insect nests) accumulated on the surfaces of the fan blade. Remove these items as they will likely disrupt airflow over the fan airfoils and can potentially cause vibration problems. 2. Inspect the fan blade for any broken, cracked or loose parts. Blade should NOT be operated with broken or loose parts. Contact dealer for determination of the repairs required. WARNING Do not attempt to pull the flange of the bushing flush with the blade hub. A clearance of 1/8'' to 1/4'' must be maintained between bushing flange and blade hub surface. Blade will loosen and cause damage or injury. Browning Taper-Lock Bushing Bolt Tightening Torque Bushing Size Hex Bolt Size Torque (inch. lbs.) H 1/4"-20 x 3/4" 95 P 5/16"-18 x 1" 192 Fan Motor Removal and Installation In the event of motor failure, remove the motor, as described and take it to the nearest Authorized Service Station. AUTHORIZED SERVICE STATIONS ARE THE ONLY PLACES THAT CAN PROVIDE MOTOR WARRANTY. Motor service and repair at other places will be at owner s expense. If service station determines motor failure to be caused by faulty material or workmanship, repair will be under warranty when within the warranty period. Motor failure because of external causes will result in a charge to the owner for repair. 1. LOCK OUT THE MAIN POWER SUPPLY, then remove fan guard, venturi and blade as outlined earlier. 2. Open motor junction box cover and disconnect the motor lead wires from within the box. NOTE: Tag or otherwise identify wires for ease of re-assembly. 3. Remove motor mount bolts. If there are any shims between the motor and its base, note their locations so they can be properly installed during re-assembly. 4. Disconnect the motor end of the motor conduit, if required, then carefully pull conduit and wires through hole in the motor junction box. Remove motor. If motor requires service, take it to an Authorized Service Station. 5. To re-install motor, slide onto motor base plate and replace shims (if required) between motor and base plate. Re-install motor mount bolts and washers and fully tighten them at this time. Re-install conduit and wires and carefully remake all electrical wiring connections. NOTE: Make sure to install and tighten the blade in accordance with earlier instructions. 24 PNEG-010 Vane Axial Fan

25 General Inspection 7. Fan Service Inspect the motor at regular intervals, approximately every 500 hours of operation or every three (3) months, whichever occurs first. Keep the motor clean and the ventilation openings clear. The following steps should be performed at each inspection: DANGER Do not touch electrical connections before you first ensure that power has been disconnected. Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the installation, operation and maintenance of this equipment. 1. Check that the motor is clean. Check that the interior and exterior of the motor is free of dirt, oil, grease, water, etc. Oily vapor, paper pulp, textile lint, etc., can accumulate and block motor ventilation. If the motor is not properly ventilated, over heating can occur and cause early motor failure. 2. Check all electrical connectors to be sure that they are tight. Lubrication and Bearings Bearing grease will lose its lubricating ability over time, not suddenly. The lubricating ability of a grease (over time) depends primarily on the type of grease, the size of the bearing, the speed at which the bearing operates and the severity of the operating conditions. Good results can be obtained if the following recommendations are used in the maintenance program. Type of grease: A high grade ball or roller bearing grease should be used. CAUTION To avoid damage to motor bearings, grease must be free of dirt. Recommended grease for standard service conditions: 1. Polyrex EM (Exxon Mobil) Equivalent and compatible greases include: 1. Texaco polystar 2. Rykon premium #2 3. Pennzoil pen 2 lube 4. Chevron SRI Lubrication Procedure Be sure that the grease you are adding to the motor is compatible with the grease already in the motor. With Grease Outlet Plug 1. Clean all grease fittings. 2. Remove grease outlet plug. 3. Add the recommended amount of grease. 4. Re-install grease outlet plug. PNEG-010 Vane Axial Fan 25

26 7. Fan Service Without Grease Outlet Plug This requires disassembly of the motor. Contact local motor shop for assistance. Volume of Grease to Relubricate Bearings (Teaspoons) NEMA Frame Size Up to 210 incl. 2 Over 210 to 280 incl. 3.9 Over 280 to 360 incl. 5.2 Over 360 to 449 incl Lubrication Intervals - Ball Bearing Motors Type of Annual Usage 1800 RPM - NEMA Frame Size 3600 RPM - NEMA Frame Size Up to 280 incl. Over 280 to 360 incl. Over 360 Up to 280 incl. Over 280 to 360 incl. Over 360 Continuous Normal Duty * 9500 Hrs 7400 Hrs 3500 Hrs 3600 Hrs 2200 Hrs 2200 Hrs Continuous Severe Duty ** 4750 Hrs 3700 Hrs 1750 Hrs 1800 Hrs 1100 Hrs 1100 Hrs Seasonal Service Motor (idle 6 months) Lubrication at beginning of season and then follow the appropriate duty interval above. * Clean, little corrosion with 40 C maximum temperature. ** Moderate dirt, corrosion with 50 C maximum temperature. Average hours per month = PNEG-010 Vane Axial Fan

27 Important Information Regarding Fuse Replacement 8. User Servicing Instructions and Troubleshooting This product employs overload protection (fuse). A blown fuse indicates an overload or short circuit situation. If the fuse blows, disconnect all power to the product. Replace the fuse as per the user servicing instructions (follow product marking for proper fuse rating) and check the product. If the replacement fuse blows, a short circuit may be present and the user should discontinue use of the product until customer service can be contacted for further assistance. Fan Troubleshooting Chart Symptom Possible Cause Solution 1. Fan does not run. 1. Blown fuse or breaker in disconnect switch. 2. Main power not turned ON. 3. Defective wiring or loose connection. 4. Incorrect wire size. 1. To replace blown fuse, grasp center of fuse securely and pull carefully outward to remove fuse from fuse holder. RISK OF FIRE. Replace fuse only with equally rated fuse shown on panel label. 2. Turn power ON at all disconnects ahead of the unit. 3. Follow wiring diagram and tighten any loose connections. 4. See wire size charts on Page 16 for proper wire size and change if needed. 5. Overload kicked out. 5. Check manual reset, push in to reset. 6. Defective motor. 6. Replace motor. 7. Defective magnetic contactor. 7. Check the magnetic contactor. 2. Fan runs for a short period of time then shuts off. 1. Undersize wiring. 2. Low line voltage at the installation power failure. 1. Check to see that power supply wires are the proper size, contact the local power company. 2. Call power company after making sure wire size is correct. 3. Magnetic contactor malfunctioning. 3. Change magnetic contactor. 4. Defective start/stop button. 4. Replace necessary part. 5. Overload setting incorrect. 5. Adjust overload to proper setting. 3. Fan makes ticking noise. 1. Fan blade hitting housing. 1. Stop fan and turn OFF power. Remove fan guard and check to see if fan blade is hitting the housing. Adjust motor or fan blade position to obtain proper clearance. 2. Motor bearing bad. 2. Replace motor bearing. 1. Fan not level. 1. Level fan. 4. Fan vibrates. 2. Fan has dirt deposit on blade. 2. Clean blade. 3. Motor shaft is bent. 3. Replace motor. 4. Blade not mounted properly on shaft. 4. Mount blade properly on shaft. 5. Blade out of balance. 5. Replace or have blade rebalanced. PNEG-010 Vane Axial Fan 27

28 8. User Servicing Instructions and Troubleshooting Fan Troubleshooting Flow Chart 28 PNEG-010 Vane Axial Fan

29 9. Parts List 12''-14'' Fan Parts Ref # Part # 12" 0.75 HP 12'' 1 HP 14'' 1 HP Description 1 F-7359 F-7225 F-7230 VA Housing Assembly 2 - MTR-0145 MTR-0145 Motor 1 HP 1 PH 3400 RPM 2 FH Motor 1 HP 1 PH 3500 RPM 3 F-7124 F-7252 F-7301 GRP - VA Blade 4 F-7233 F-7233 F-7233 GRP - Safety Washer 5 F-7177 F-7177 F-7178 Grill Guard 6 S-3611 S-6606 S-6606 Flange Bolt 5/16"-18 x 3/4" ZN Grade 5 7 S-845 S-3611 S-3611 Flange Nut 5/16"-18 ZN YDP 8 S-6606 S-845 S-845 Flat Washer 5/16" USS SAE YDP Grade 2 PNEG-010 Vane Axial Fan 29

30 9. Parts List 18''-28'' Fan Parts Part # Ref # Description 18'' 1.5 HP 18'' 3 HP 24'' 7 HP 24'' 10 HP 28'' 15 HP 1 FH-5535 FH-3660 F-7199 F-7199 F-7199 Split Taper Bushing 2 F-7179 F W W W Grill Guard 3 F-7248 F-7248 F-7513 F-7513 F-7516 Fan Housing without Controls 3 N/A F-7510 F-7513 F-7513 F-7516 Fan Housing with Controls 4 F-7254 F-7255 F-6920 F-6921 F-6923 Blade Assembly 5 MTR-0147 MTR-0141 MTR-0142 MTR-0143 MTR V 1 PH Motor 5 MTR-0002 MTR-0003 MTR-0088 MTR-0089 MTR V/460V 3 PH Motor 5 FH-6592 FH-6593 FH-6594 FH-6595 FH V 3 PH Motor 6 PR-331 PR-331 PR-331 PR-331 PR-331 Handle 7 FH-6972 FH-6972 C-8824 C-8824 C-8824 Junction Enclosure 7 N/A C-8803 C-8803 C-8803 C-8803 Control Enclosure 8 N/A N/A F-7316 F-7316 F-7317 Venturi (Yellow) 8 N/A N/A Venturi (Orange) 9 FH-7518 FH-7518 FH-7519 FH-7519 FH-7521 Control Enclosure Mount 30 PNEG-010 Vane Axial Fan

31 10. Wiring Diagrams 1. 1 Phase 230 Volt Schematic 2. 1 Phase 230 Volt Wiring Diagram and Parts 3. 3 Phase 230 Volt Schematic 4. 3 Phase 230 Volt Wiring Diagram and Parts 5. 3 Phase 460 Volt Schematic 6. 3 Phase 460 Volt Wiring Diagram and Parts 7. 3 Phase 575 Volt Schematic 8. 3 Phase 575 Volt Wiring Diagram and Parts PNEG-010 Vane Axial Fan 31

32 10. Wiring Diagrams 1 Phase 230 Volt Schematic 32 PNEG-010 Vane Axial Fan

33 10. Wiring Diagrams 1 Phase 230 Volt Wiring Diagram and Parts Ref # Part # Description 1 C-8707 Mounting Plate 2 E Ground Lug 3 C-8718 Single Pole Fuse Block 4 C A Slow Blow Fuse 5 C-8715 Fuse Puller 6 C-8716 ON/OFF Switch Assembly HP 230V 1 PH Contactor HP 230V 1 PH Contactor HP 230V 1 PH Contactor HP 230V 1 PH Contactor HP 230V 1 PH Contactor HP 230V 1 PH Overload 8 CH HP 230V 1 PH Overload 8 CH HP 230V 1 PH Overload 8 CH HP 230V 1 PH Overload 8 CH HP 230V 1 PH Overload 9 C-8717 Cable Tie 10 S-1158 Screw, TCSF #8-32 x 1/2" PHP ZN PNEG-010 Vane Axial Fan 33

34 10. Wiring Diagrams 3 Phase 230 Volt Schematic 34 PNEG-010 Vane Axial Fan

35 10. Wiring Diagrams 3 Phase 230 Volt Wiring Diagram and Parts Ref # Part # Description 1 C-8707 Mounting Plate 2 E Ground Lug 3 C-8716 ON/OFF Switch Assembly 4 C-8718 Single Pole Fuse Block 5 C A Slow Blow Fuse 6 C-8717 Cable Tie 7 C-8715 Fuse Puller HP 230V 3 PH Contactor HP 230V 3 PH Contactor HP 230V 3 PH Contactor HP 230V 3 PH Contactor HP 230V 3 PH Contactor HP 230V 3 PH Overload HP 230V 3 PH Overload 9 CH HP 230V 3 PH Overload 9 CH HP 230V 3 PH Overload 9 CH HP 230V 3 PH Overload 10 S-1158 Screw, TCSF #8-32 x 1/2" PHP ZN PNEG-010 Vane Axial Fan 35

36 10. Wiring Diagrams 3 Phase 460 Volt Schematic 36 PNEG-010 Vane Axial Fan

37 10. Wiring Diagrams 3 Phase 460 Volt Wiring Diagram and Parts Ref # Part # Description 1 C-8707 Mounting Plate 2 C-8715 Fuse Puller 3 C-8716 ON/OFF Switch Assembly 4 C A Slow Blow Fuse 5 C-8720 Class CC Slow Blow Fuse 6 E Ground Lug 7 C-8717 Cable Tie Side Mount Contact 9 S-1158 Screw, TCSF #8-32 x 1/2" PHP ZN HP 460V 3 PH Contactor HP 460V 3 PH Contactor HP 460V 3 PH Contactor HP 460V 3 PH Contactor HP 460V 3 PH Contactor 11 CH HP 460V 3 PH Overload 11 CH HP 460V 3 PH Overload HP 460V 3 PH Overload HP 460V 3 PH Overload 11 CH HP 460V 3 PH Overload 12 C V 3 PH Transformer PNEG-010 Vane Axial Fan 37

38 10. Wiring Diagrams 3 Phase 575 Volt Schematic 38 PNEG-010 Vane Axial Fan

39 10. Wiring Diagrams 3 Phase 575 Volt Wiring Diagram and Parts Ref # Part # Description 1 C-8707 Mounting Plate 2 C-8715 Fuse Puller 3 C-8716 ON/OFF Switch Assembly 4 C A Slow Blow Fuse 5 C-8720 Class CC Slow Blow Fuse 6 E Ground Lug 7 C-8717 Cable Tie Side Mount Contact 9 S-1158 Screw, TCSF #8-32 x 1/2" PHP ZN HP 575V 3 PH Contactor HP 575V 3 PH Contactor HP 575V 3 PH Contactor HP 575V 3 PH Contactor HP 575V 3 PH Contactor 11 CH HP 575V 3 PH Overload 11 CH HP 575V 3 PH Overload HP 575V 3 PH Overload HP 575V 3 PH Overload HP 575V 3 PH Overload 12 C V 3 PH Transformer PNEG-010 Vane Axial Fan 39

40 NOTES 40 PNEG-010 Vane Axial Fan

41 11. Warranty GSI Group, LLC Limited Warranty The GSI Group, LLC ( GSI ) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier. The end-user s sole remedy (and GSI s only obligation) is to repair or replace, at GSI s option and expense, products that in GSI s judgment, contain a material defect in materials or workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI Warranty Group shall be the sole responsibility of the end-user. Warranty Extensions: The Limited Warranty period is extended for the following products: Product Warranty Period Performer Series Direct Drive Fan Motor 3 Years * Warranty prorated from list price: AP Fans and Flooring All Fiberglass Housings Lifetime 0 to 3 years - no cost to end-user All Fiberglass Propellers Lifetime 3 to 5 years - end-user pays 25% 5 to 7 years - end-user pays 50% Feeder System Pan Assemblies 5 Years ** 7 to 10 years - end-user pays 75% Cumberland Feed Tubes (1-3/4" and 2.00") 10 Years * ** Warranty prorated from list price: Feeding/Watering Systems Centerless Augers 10 Years * 0 to 3 years - no cost to end-user Watering Nipples 10 Years * 3 to 5 years - end-user pays 50% Grain Systems Grain Bin Structural Design 5 Years Grain Systems Portable and Tower Dryers 2 Years Motors, burner components and moving parts not included. Farm Fans Portable and Tower Dryer Frames and Portable dryer screens included. Zimmerman 5 Years Internal Infrastructure Tower dryer screens not included. GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components, shall be free from defects in materials for a period of time beginning on the twelfth (12 th ) month from the date of purchase and continuing until the sixtieth (60 th ) month from the date of purchase (extended warranty period). During the extended warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this extended warranty. Conditions and Limitations: THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH: (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS. GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent or distributor. GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at initial sale will void the Limited Warranty. This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, alteration, accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products manufactured by GSI. Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the location and installation of products manufactured or sold by GSI _1_CR_rev7.DOC (revised July 2009) PNEG-010 Vane Axial Fan 41

42 This equipment shall be installed in accordance with the current installation codes and applicable regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. GSI Group 1004 E. Illinois St. Assumption, IL Phone: Fax: GSI is a worldwide brand of AGCO Corporation. Copyright 2014 by GSI Group Printed in the USA CN

Humidistat-Thermostat

Humidistat-Thermostat Humidistat-Thermostat Model # HF _- - - Owner s Manual PNEG-236 Date: 12-02-09 PNEG-236 2 PNEG-236 Humidistat-Thermostat Table of Contents Contents Chapter 1 Safety... 4 Safety Guidelines... 4 Humidistat-Thermostat

More information

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640 Smart IR Sensor Installation and Operation Manual PNEG-1640 Date: 12-21-11 PNEG-1640 2 PNEG-1640 Smart IR Sensor Table of Contents Contents Chapter 1 Safety...4 Safety Guidelines...4 Chapter 2 Application...6

More information

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Installation Manual PNEG-1982 Date: 03-26-15 PNEG-1982 2 PNEG-1982 Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Table

More information

MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS)

MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS) Vane Axial Fan MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS) Owner's Manual MANUAL # PNEG-0-C 1 FAN CHECK LIST OK 1. All wire connections 2. Tip clearance on blade 3. Fan blade torqued to

More information

CE Approved Portable Dryer Wiring Diagrams. Model: 1200 Series. Electrical Installation Manual PNEG Version: 1.0. Date: PNEG-2119

CE Approved Portable Dryer Wiring Diagrams. Model: 1200 Series. Electrical Installation Manual PNEG Version: 1.0. Date: PNEG-2119 CE Approved Portable Dryer Wiring Diagrams Model: 1200 Series Electrical Installation Manual PNEG-2119 Version: 1.0 Date: 11-01-16 PNEG-2119 All information, illustrations, photos and specifications in

More information

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION Ultra Clean Installation and Operation Manual LAMBTON CONVEYOR LIMITED ONE SOURCE 1 Contents Warranty... 4 Section 1. Safety... 5 Section 2. Decals... 8 Section 3. Product Information... 9 Ultra Clean

More information

Digital Moisture Control Thermostat

Digital Moisture Control Thermostat Digital Moisture Control Thermostat Installation and Operation Manual PNEG 1711 Date: 2009 PNEG - 1711 Page 1 of 22 06/30/2009 READ THESE INSTRUCTIONS BEFORE INSTALLATION and OPERATION. SAVE FOR FUTURE

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before

More information

Tower Dryer PLC Watchdog

Tower Dryer PLC Watchdog Tower Dryer PLC Watchdog Operation Manual PNEG-2134 Version: 1.0 Date: 04-09-18 PNEG-2134 All information, illustrations, photos and specifications in this manual are based on the latest information available

More information

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual Air Storm 24 Fiberglass Fan Installation and Operation Manual Hog Slat Inc. Newton Grove, NC USA May 2015 Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5

More information

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual Air Storm 18 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5 Operation Safety...5 Maintenance Safety...5

More information

Parts List Supplement for ETL/CSA Dryers. Parts Manual PNEG Date: Version: 2.0 PNEG-1763

Parts List Supplement for ETL/CSA Dryers. Parts Manual PNEG Date: Version: 2.0 PNEG-1763 Parts List Supplement for ETL/CSA Dryers Parts Manual PNEG-1763 Version: 2.0 Date: 11-24-16 PNEG-1763 All information, illustrations, photos and specifications in this manual are based on the latest information

More information

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual Air Storm 54 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page... 3 Safety... 4 Warning Labels... 4 Installation... 5 Operation Safety... 5 Maintenance Safety...

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended

More information

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) Galvanized Panel Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble,

More information

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO

More information

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING 12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING This manual contains very important safety warnings and information. Read and save these instructions for future

More information

IMPORTANT INSTRUCTIONS

IMPORTANT INSTRUCTIONS IMPORTANT INSTRUCTIONS W Fan Force Electric Space Heater DANGER ELECTRIC SHOCK OR FIRE HAZARD Figure 1 Covers all W Series models WARNING Read Carefully - These instructions are written in an effort to

More information

SUPERFLOW FULL CENTRIFUGAL FAN MODELS: 3HP, 5HP, 7HP, 10HP, 15HP, & 30HP INSTALLATION, OPERATION, AND PARTS MANUAL

SUPERFLOW FULL CENTRIFUGAL FAN MODELS: 3HP, 5HP, 7HP, 10HP, 15HP, & 30HP INSTALLATION, OPERATION, AND PARTS MANUAL SUPERFLOW FULL CENTRIFUGAL FAN MODELS: INSTALLATION, OPERATION, AND PARTS MANUAL IMPORTANT: READ AND SAVE THESE INSTRUCTIONS INSTALLATION AND WIRING MUST BE IN ACCORDANCE WITH CEC, NEC AND LOCAL ELECTRICAL

More information

Single-Module Portable Dryer

Single-Module Portable Dryer Single-Module Portable Dryer Models: 1100, 1200, 1200S CFAB-1 FAN, CFAB- 2 FAN, C2100A Installation Guide PNEG-1891 Version 3.1 Date: 09-09-16 PNEG-1891 All information, illustrations, photos, and specifications

More information

60In. Ceiling Fan. Owner s Manual

60In. Ceiling Fan. Owner s Manual 60In. Ceiling Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

CENTRIFUGAL FAN RPM MODELS: GGL SERIES 5HP, 7HP, 10HP, 15HP, 20HP, 25HP, 30HP INSTALLATION, OPERATION, AND PARTS MANUAL

CENTRIFUGAL FAN RPM MODELS: GGL SERIES 5HP, 7HP, 10HP, 15HP, 20HP, 25HP, 30HP INSTALLATION, OPERATION, AND PARTS MANUAL CENTRIFUGAL FAN - 1750 RPM MODELS: INSTALLATION, OPERATION, AND PARTS MANUAL IMPORTANT: READ AND SAVE THESE INSTRUCTIONS INSTALLATION AND WIRING MUST BE IN ACCORDANCE WITH CEC, NEC AND LOCAL ELECTRICAL

More information

User Manual Box Exhaust Fan Series (Belt Drive)

User Manual Box Exhaust Fan Series (Belt Drive) User Manual Box Exhaust Fan Series (Belt Drive) 36" Box Exhaust Fan with Three Wing Blade Box with Aluminum Shutter 54" Box with Cone 800-779-3267 sales@schaeferfan.com www.schaeferfan.com 2013 Schaefer

More information

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 INSTALLATION-OPERATION-MAINTENANCE CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015 TEFC 3 phase motor Outlet duct Fan wheel housing Inlet duct connection After filter transition Optional after filter unit

More information

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive) 36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

High-Velocity Floor Fan

High-Velocity Floor Fan High-Velocity Floor Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION

More information

22In. Oscillating Pedestal Fan. Owner s Manual

22In. Oscillating Pedestal Fan. Owner s Manual 22In. Oscillating Pedestal Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

Marley Ultra Quiet Fan

Marley Ultra Quiet Fan USER MANUAL Marley Ultra Quiet Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2012-1165 ISSUED 8/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

57" Fiberglass Exhaust Fan with Cone

57 Fiberglass Exhaust Fan with Cone OPERATORS MANUAL Fiberglass Exhaust Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate or service the product described. Failure

More information

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output Operating Instructions & Parts Manual 1RKT2, 1RKT3, 1RKT4, 1RKT5, 1RKT9 and 1RKU2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

1 HP Air Mover. Owner s Manual

1 HP Air Mover. Owner s Manual 1 HP Air Mover Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual

More information

CL & CLG Clamp Mount Mixers

CL & CLG Clamp Mount Mixers CL & CLG Clamp Mount Mixers CL / CLG Series OWNERS MANUAL Warranty Our products are guaranteed against defective materials and workmanship, we will repair or replace such items as may prove defective at

More information

R Series B & T2 Model

R Series B & T2 Model FRONT R Series B & T2 Model Fan Forced Wall Heaters 4-1/4 (108mm) NOTE: Knockouts in top same dimensions 3-1/4 3-1/4 (108mm) (108mm) as bottom 16-7/8 (429mm) 13-7/8 (352mm) BOTTOM 13-7/8 (352mm) 7-3/4

More information

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL SWP (Models SWP08 through SWP20) OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Please read and save these instructions. Read carefully before

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE USER MANUAL ultra quiet fan INSTALLATION OPERATION MAINTENANCE Z0414808 rev A ISSUED 02/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and handling Safety Warning

More information

CENTRIFUGAL FAN Owner's and Operator's Manual (CE Models)

CENTRIFUGAL FAN Owner's and Operator's Manual (CE Models) CENTRIFUGAL FAN Owner's and Operator's Manual (CE Models) ATTENTION Pay close attention when you see this triangular symbol. It will be located throughout this manual and on decals. Obey the Dangers, Warnings

More information

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

Operator s Manual S-333. Automated Soil Compactor. Version 3.3. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA Automated Soil Compactor S-333 Operator s Manual Version 3.3 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail:

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS USER MANUAL Marley X7 Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2010-1234A ISSUED 3/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. Fan Components 1

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual Ring Blower Side Channel Blower Regenerative Blower Systems www.republicsales.com Revised 7.08 2006 Sales & Manufacturing Regenerative Blowers Criteria Use Criteria Use only clean, dry air. Do not use

More information

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive) TURBO Hooded Fans Installation & Operator s Manual (14, 18, & 24 Direct Drive) August 1996 MV1089B8 WARRANTY INFORMATION Chore-Time Equipment warrants each new product manufactured by it to be free from

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

Electric Space Heater

Electric Space Heater The Choice of Professionals Model No. FUH Series Electric Space Heater Installation & Maintenance Instructions SPECIFICATIONS: FUH 54B Heater Rating and Voltage 5000 W @ 40V 465W @ 40V 333W @ 40V 500W

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air

More information

XC Portable Air Conditioning

XC Portable Air Conditioning PORTABLE AIR CONDITIONERS XC Portable Air Conditioning XC-14A, XC-22A, XC-30A Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents

More information

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL Heated Air Curtains MODELS: INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL E3606-1125HFD, E3609-1125HFD, E3612-1125HFD E3806-1125HFD, E3809-1125HFD, E3812-1125HFD E4206-1125HFD, E4209-1125HFD, E4212-1125HFD

More information

OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A

OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A OWNER S MANUAL General Ventilation Fans Electric Driven HD Series (Incl. -T & -S) PAL Series (Incl. 24 & 30) 0316_01A INTRODUCTION Thank you for choosing Tempest Technology Corporation for your ventilation

More information

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS VENTILATOR USER GUIDE MODEL HF124 USER GUIDE This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators Please take the time to read this manual

More information

40E ELECTRIC FAN HEATER

40E ELECTRIC FAN HEATER 40E ELECTRIC FAN HEATER PRODUCT MANUAL IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM- BLING, STARTING OR SERVICING THE HEATER. IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY. KEEP THIS MANUAL

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE SPACESAVER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.

More information

40E ELECTRIC FAN HEATER

40E ELECTRIC FAN HEATER 40E ELECTRIC FAN HEATER PRODUCT MANUAL IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM- BLING, STARTING OR SERVICING THE HEATER. IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY. KEEP THIS MANUAL

More information

PORTABLE HAND POWER THREADER 1/2-2

PORTABLE HAND POWER THREADER 1/2-2 PORTABLE HAND POWER THREADER 1/2-2 Read this Operator s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock, fire and/or

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual before

More information

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg. The Extraordinaire Orbital Fan WARNING: Support Directly From Building Structure Net Weight 14.5 lbs. or 6.59 kg. Model No. OF110** OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions

More information

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual WS-63TB36SS WS-63TB42SS ISLAND SERIES NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS. TABLE OF CONTENTS 1 Table of Contents www.windsterhood.com Safety Information... 2 3 WALL MOUNT SERIES User s Manual RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS NOTE: PLEASE

More information

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual 8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

Wet/Dry Vacuum Kit

Wet/Dry Vacuum Kit Wet/Dry Vacuum Kit 54-0011-6 Owner ' s Manual Toll-Free Helpline: 1-866-JOBMATE (562-6283) Version 3.3 Table of Contents SECTION Page Specifications...2 Safety Warnings... 3 Location of Parts..... 5 General

More information

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be

More information

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.NUTONE.COM 1-888-336-3948 REGISTER YOUR PRODUCT ONLINE

More information

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE THE HOTTEST MACHINES ON ICE CORNELIUS INC www.cornelius.com IMPORTANT: TO THE INSTALLER. It is the responsibility of the Installer to ensure

More information

breeze easytm model # F100-1W

breeze easytm model # F100-1W DewStop breeze easytm model # F100-1W Installation Guide Read and Save These Instructions LISTED Questions, Problems, Missing Parts? Please Call 1-360-876-2974 or E-Mail info@dewstop.com please retain

More information

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

100In. High Volume Ceiling Fan. Owner s Manual

100In. High Volume Ceiling Fan. Owner s Manual 100In. High Volume Ceiling Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS Fan Models: CX1401, CX1801 Read all warnings and instructions before beginning to install this fan. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

More information

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) Our Expertise, Your Air-Moving Solution ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) PART# 0601710001_rev_A INSTALLATION, OPERATION & MAINTENANCE MANUAL Please read and save these instructions for future reference.

More information

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

VSA/VSB & KSA/KSB Series Air Doors

VSA/VSB & KSA/KSB Series Air Doors READ AND SAVE THESE INSTRUCTIONS No.: II-230 Date: October, 2007 VSA/VSB & KSA/KSB Series Air Doors Installation & Maintenance Instructions WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

More information

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-71 SinkSpa JETTED SINK Model LJD1306L JOB AID Part No. 8178201 FORWARD This Whirlpool Job Aid, SinkSpa Jetted Sink, (Part No. 8178201), provides the

More information

AeroVent 3X Product Manual

AeroVent 3X Product Manual Product Manual AeroVent 3X TABLE OF CONTENTS Precautionary Warning... Page 1 Assembly... Page 2 Assembly Drawing... Page 3 Parts List... Page 3 Operation... Page 4 Maintenance... Page 5 Cobalt Point Replacement...

More information

THERMAL SYSTEMS, INC. Installation and Operation Manual

THERMAL SYSTEMS, INC. Installation and Operation Manual THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never

More information

Irene READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Irene READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz Irene 60", 52" or 42" CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information