Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Size: px
Start display at page:

Download "Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities"

Transcription

1 Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H

2 Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series gas fired DOUBLE-EFFECT chiller-heaters, with cooling capacities of 150 and 200 tons of refrigeration, are designed for commercial applications where chilled water and hot water are used in a central air conditioning system. The condenser is water cooled and heat is rejected through a cooling tower. The Yazaki absorption chiller-heater uses a solution of lithium bromide and water, under a vacuum, as the working fluid. is the refrigerant and lithium bromide, a nontoxic salt, is the absorbent. The double-effect absorption cycle has two generators - one directly heated by a gas burner and the other heated by hot refrigerant vapor. Refrigerant, liberated by heat from the solution, produces a refrigerating effect in the evaporator when cooling water is circulated through the condenser and absorber. Cycle LOW TEMP GENERATOR Refrigerant Vapor CHANGEOVER VALVE (Refrigerant) SEPARATOR HIGH TEMP GENERATOR CONDENSER ORIFICE EVAPORATOR Chilled ABSORBER Dilute Solution Concentrated Solution Refrigerant Vapor Refrigerant Liquid Chilled Gas Supply BURNER HEAT EXCHANGER SOLUTION PUMP CHANGEOVER VALVE (Solution) High-Temperature Generator The gas burner heats dilute lithium bromide solution in the high-temperature generator and, as the solution boils vigorously under a vacuum, droplets of concentrated solution are carried with refrigerant vapor to the separator. After separation, hot refrigerant vapor flows to the low-temperature generator and concentrated solution is precooled in the heat exchanger before flowing to the absorber. Low-Temperature Generator Hot refrigerant vapor from the separator heats dilute lithium bromide solution in the lowtemperature generator. Refrigerant vapor, liberated from this solution, flows to the condenser while solution, which is now concentrated, is precooled in the heat exchanger before flowing to the absorber. Condenser In the condenser, refrigerant vapor is condensed on the surface of the coil and latent heat, removed by the cooling water, is rejected to a cooling tower. Refrigerant liquid accumulates in the condenser and then passes through an orifice into the evaporator. 2

3 Evaporator In the evaporator, refrigerant liquid is exposed to a substantially deeper vacuum than in the condenser due to the influence of the absorber. As refrigerant liquid flows over the surface of the evaporator coil it boils and removes heat, equivalent to the latent heat of the refrigerant, from the chilled water circuit. The recirculating chilled water is cooled to 44.6 F and the refrigerant vapor is attracted to the absorber. Absorber A deep vacuum in the absorber is maintained by the affinity of the concentrated solution from the generator with the refrigerant vapor formed in the evaporator. Refrigerant vapor is absorbed by concentrated lithium bromide solution flowing across the surface of the absorber coil. Heat of condensation and dilution are removed by the cooling water and rejected to a cooling tower. The resulting dilute solution is preheated in the heat exchanger before returning to the generator where the cycle is repeated. Heating Cycle LOW TEMP GENERATOR CHANGEOVER VALVE (Refrigerant) SEPARATOR HIGH TEMP GENERATOR CONDENSER ORIFICE EVAPORATOR Hot ABSORBER Dilute Solution Concentrated Solution Refrigerant Vapor Refrigerant Liquid Hot Gas Supply BURNER HEAT EXCHANGER SOLUTION PUMP CHANGEOVER VALVE (Solution) High-Temperature Generator Dilute lithium bromide solution is heated in the high-temperature generator by the gas burner in the same manner as the cooling cycle. The solution boils vigorously and droplets of concentrated solution are carried with refrigerant vapor to the separator. Hot refrigerant vapor flows through the refrigerant changeover valve into the evaporator and concentrated solution flows through the solution changeover valve into the absorber sump. Evaporator Hot refrigerant vapor condenses on the surface of the evaporator coil and heat, equivalent to the latent heat of the refrigerant, is transferred to the hot water circuit. The recirculating water is heated to 140 F. Absorber Refrigerant liquid mixes with concentrated lithium bromide solution and the resulting dilute solution returns to the generator where the cycle is repeated. 3

4 Features & Benefits n Each Chiller-Heater Serves a Dual Purpose: and Heating This compact chiller-heater reduces floor space and installation costs because it replaces the traditional chiller-boiler combination and simplifies piping, pumps, valves and controls. n High COP of 1.2 Reduces fuel consumption and operating costs by up to 17% compared with other double-effect absorption units. n Part Load IPLV Rating >1.3 Reduces seasonal fuel consumption because the chiller operates more efficiently at part load for most of the time. n Low NOx Gas Burner <30 ppm Advanced Riello low NOx gas burners are used to meet the strict air quality requirements of California and other states. n Hermetic Integrity Strict quality control and testing with a mass spectrometer ensures the vacuum section is airtight and eliminates the need for an onboard mechanical purge pump. Hydrogen, a by-product of the absorption cycle, is continuously removed through a palladium cell or stored with other noncondensible gases in an external purge tank n PID Microprocessor PID (proportional, integral and differential) controls are utilized to optimize the absorption cycle performance and provide stable chilled water and hot water outlet temperatures under all load conditions. n Burner Firing is Modulated 30% to 100% The burner is proportionally controlled to match the output capacity of the chillerheater and reduce operating costs. n Safe, Odorless, Non-toxic Working Fluids Ozone safe and CFC free. Working fluids of non-toxic lithium bromide and water operate safely under a vacuum at all times. n A Single VFD Hermetic Solution Pump One variable speed pump circulates solution and reduces electrical consumption at part load. Additional pumps are not required because gravity feed drippers are used to distribute refrigerant and solution instead of spray nozzles. This eliminates the need for periodic nozzle maintenance. n Low Temperature operation allowed down to 65 F inlet cooling water without the need for cooling tower bypass control. n Weatherproof Cabinet Equipment room is not required because the chiller-heater is enclosed in a weatherproof cabinet suitable for indoor or outdoor installation. n Low Electrical Consumption Since less than 19.3 VA/RT is required to operate the chiller-heater, it is not neccessary to upgrade the existing electrical service. 4

5 Features & Benefits (Continued) n Built-In Shutdown Controls Safely shuts down the chiller-heater under abnormal operating conditions. n Ideal for a Two Pipe Hydronic System Installation costs reduced because only two pipes are required to transport chilled or hot water to a central air handling unit or multiple fan-coil units. n 30 Minute Changeover /heating changeover only requires a 30 minute delay. n Simple Mode Selection or heating operation can be selected at the chiller-heater or remotely from the building management system. n Built-In Digital Display Panel Used for mode selection, operating status and troubleshooting. n Remote Chilled and Hot Reset Raise chilled water setpoint or lower hot water setpoint to reduce operating costs during unoccupied hours. n Hinged Marine Boxes Allow easy access to the condenser and absorber for tube cleaning and maintenance without disconnecting piping. n Factory Installed Crossover Pipe and Insulation Eliminates site fabrication and installation of crossover pipe between the absorber and condenser and site insulation of cold and hot surfaces. n Simplified Transportation and Lifting Each modular chiller-heater is mounted on a steel frame and anchor points are provided for lifting. n Quiet Operation Since the chiller-heater has relatively few moving parts, the noise level is typically less than 74idB(A) and there is no vibration. The chiller-heater is ideal for installation adjacent to occupied spaces because it does not compromise occupant comfort. n Simple Maintenance Only two routine service calls are required per year to evacuate noncondensible gases and check other operating conditions. Start-up, routine maintenance and troubleshooting are provided by a network of independent Yazaki authorized service providers with backup from the factory. n Factory Charged and Performance Tested Since each chiller-heater is shipped completely assembled and tested, installation and start-up are simplified. n ISO9001 and ISO14001 Factory Certification Quality control is assured by compliance with strict manufacturing and industry standards. n UL Listed for USA and Canada 5

6 Control Characteristics 57.2 PID COOLING CONTROL Chilled Temp. ( F) % Load % Load Time (min) 80% Load Chilled Inlet Temp. Chilled Outlet Temp. Proportional Control Digital PID Control PID HEATING CONTROL Hot Temp. ( F) % % Load Load Time (min) 80% Load Hot Outlet Temp. Hot Inlet Temp. Proportional Control Digital PID Control COOLING SETPOINT Maximum Setpoint HEATING SETPOINT Maximum Setpoint Chilled Outlet Temp. ( F) Minimum Setpoint Hot Outlet Temp. ( F) Time (min) Standard Rating Point Digital PID Control Minimum Setpoint Time (min) 6

7 Application (Gas Fired & Heating System Operation) FAN COIL UNIT COOL AIR Gas Supply GAS FIRED DOUBLE-EFFECT CHILLER-HEATER COOLING TOWER Dilute Solution Concentrated Solution Refrigerant Vapor Refrigerant Liquid Chilled Standard Specification NOTES: 1. Fuel input is based on HIGHER HEATING VALUE of gas. 2. Specifications are based on water in all circuits and fouling factor of ft 2 hr. F/Btu. 3. Do not exceed 114 psi operating pressure in any water circuit. 4. Chilled/hot water flow limits are 80~120% of standard rating. 5. water flow limits are 100~120% of standard rating. 6. Two or more modules may be installed in parallel for larger capacities. 7. Standard natural gas supply pressure is 7.0 in. wc. 8. Sound pressure noise level measured in a free field at a point 39 in. in front of the chiller-heater and 59 in. above the ground. MODEL CH-MG150 CH-MG200 Capacity (Btu/hr x 1000) 1,800 2,400 Chilled Temp. ( F) 44.6 Outlet, 53.6 Inlet Heating Capacity (Btu/hr x 1000) 1,245 1,660 Hot Temp. ( F) Outlet, Inlet Chilled/Hot Rated Flow (gpm) Evap. Press. Loss (psi) Retention Volume (gal) Heat Rejection (Btu/hr x 1000) 3,045 4,060 Temp. ( F) 85.1 Inlet, 94.3 Outlet *Rated Flow (gpm) Cond./Abs. Press. Loss (psi) Retention Volume (gal) Type Natural Gas Fuel Input (Btu/hr 1,500 2,000 x 1000) Heating 1,500 2,000 Power Supply 208V or 230V, 60Hz, 3ph Electrical Consumption (kva) Heating Control and Heating 30% - 100% PID Control Type Low NOx Forced Draft Burner Combustion Flame Detection UV Scanner Ignition Intermittent Spark Noise Level Sound Pressure db(a) Chilled/Hot (in) 4 Flange 5 Flange Piping (in) 5 Flange 6 Flange Gas Supply (in) 2 NPT 2 NPT Exhaust Vent (in) 13.8 x 9.8 (inside) Weight Dry (lb) 12,346 14,330 Operating (lb) 13,698 16,183 Type Weatherproof Cabinet Material Pre-painted hot dipped galvanized steel Finish Silver metallic * Minimum cooling water flow 7

8 Expanded Performance NOTES: 1. Capacities are based on standard gas input ratings. 2. Standard water flow rates used in all circuits. 3. Fouling factor of ft 2 hr. F/Btu in the condenser/absorber and evaporator. 4. Performance data may be interpolated but must not be extrapolated. 5. Expanded performance data is provided for reference only. Contact Yazaki Energy Systems, Inc. for certified data or performance at other conditions. TEMPERATURE ( F) COOLING CAPACITY & HEAT REJECTION (Btu/hr x 1000) Inlet Chilled Outlet Capacity 1,582 1,743 1,831 1,862 1,877 1,477 1,679 1,800 1,830 1,853 1,305 1,584 1,750 1,796 1,836 CH-MG150 Heat Rejection 2,827 2,988 3,076 3,107 3,122 2,722 2,924 3,045 3,075 3,098 2,550 2,829 2,995 3,041 3,081 NOTE: Data highlighted is based on standard rated conditions. Capacity 2, ,442 2,483 2,503 1,969 2,238 2,400 2,440 2,470 1,740 2,112 2,334 2,395 2,448 CH-MG200 Heat Rejection 3,770 3,984 4,102 4,143 4,163 3,629 3,898 4,060 4,100 4,130 3,400 3,772 3,994 4,055 4,108 Part Load Performance Normally, for comfort cooling applications the chiller-heater will operate at part load cooling for most of the time. Since less heat is rejected through the cooling tower during part load cooling operation, the lower cooling water temperature improves the cooling performance by increasing the Coefficient of Performance (COP) and reducing the gas input. The chiller-heater can operate with 65 F minimum cooling water inlet temperature without the need for cooling tower bypass control. NOTES: 1. Fuel Input (%) is gas consumption as percentage of full load rated fuel input. 2. Capacity (%) is percentage of full load rated cooling capacity. 3. Broken line indicates part load characteristics at full load rated COP. Fuel Input (%) F Chilled Outlet ARI Part Load Inlet Temperatures A (85.0 F), B (77.5 F), C (70.0 F) C Capacity (%) B A

9 Part Load IPLV Rating ARI Integrated Part Load Value (IPLV) is a single number measure of part load cooling performance based on a w e i g h t e d a v e r a g e o f c o m m o n b u i l d i n g t y p e s, operating hours and average U.S.A. weather data. Part load performance is often expressed as Coefficient of Performance (COP): COP = Net Output Net Input IPLV = 0.01A+0.42B+0.45C+0.12D COP C 70.0 F Inlet 77.5 F Inlet 85.0 F Inlet B Where A, B, C and D are part load COP s at the following conditions: POINT COOLING COOLING CAPACITY (%) WATER TEMP ( F) A B C D Since the minimum gas input to the chiller-heater is 30%, the corresponding cooling capacity at 70.0 F cooling water inlet is 33.6%. The equivalent COP at 25% cooling capacity (Point D) is calculated from this condition to account for cycling. Part Load Heating Performance During part load operation, the heating efficiency of the chiller-heater increases. As the firing rate is reduced, the burner modulates both fuel and air; and the ratio of heat exchanger surface area to fuel input increases. NOTE: Fuel Input (%) is gas consumption as percentage of full load rated fuel input. POINT Thermal Efficiency (%) A B C D COOLING CAPACITY (%) COOLING WATER TEMP ( F) * Calculated as per ARI Capacity (%) COP * Fuel Input (%) A ARI WEIGHTED FACTOR IPLV WEIGHTED AVERAGE COP

10 Typical Piping SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION T Temp. gauge P Pressure gauge F Gas meter Reducing valve Check valve Expansion joint COOLING TOWER LS (Optional) CTS CWV M Strainer Flush Valve Inlet IF2 (Optional) CWTS P P T Relief valve Outlet T CHILLER-HEATER Expansion tank T T Manual valve Chilled/Hot Outlet Chilled/Hot Intlet Air Vent P P T P T P Supply AIR HANDLING UNIT FAN COIL UNIT FAN COIL UNIT Return Drain COOLING WATER PUMP Supply Flush Valve Drain F Gas Inlet IF1 (Optional) Drain Drain CHILLED/HOT WATER PUMP Supply Drain Typical Field Wiring COOLING TOWER CWV M LS (Optional) CTS COOLING WATER PUMP CHILLED/HOT WATER PUMP CWTS POWER BOX (Supplied by Others) OPTIONAL CONTROL BOX CONNECTIONS OPTIONAL JUNCTION BOX CONNECTIONS JB CHILLER- HEATER CB WIRING (Number of Conductors) FUSED DISCONNECTS SYMBOL DESCRIPTION SYMBOL DESCRIPTION IF1 Chilled/hot water freeze switch CTS tower switch IF2 water freeze switch LS Level switch CWTS water temperature switch CWV water control valve Power Supply (208V or 230V, 60Hz, 3ph) IF1 (Optional) IF2 (Optional) STANDARD JUNCTION BOX (JB) CONNECTIONS Power supply. Chilled/hot water and cooling water pump control. Thermal overload interlocks from chilled/hot water pump, cooling water pump and cooling tower fan. OPTIONAL JUNCTION BOX (JB) CONNECTIONS Remote cooling/heating mode selection. Remote start/stop selection. tower fan control output (Alternative to CTS). OPTIONAL CONTROL BOX (CB) CONNECTIONS /heating mode status. Chiller-heater operating status. Chiller-heater standby status. Dilution cycle status. Burner operating status. General shutdown alarm output. External fault alarm output. Main fault alarm output. Burner flame failure alarm. External fault interlock (Additional control supplied by others). Earthquake switch shutdown. Remote temperature control 4.5 F setup/setback. 10 water flow switch (FS2) input (Flow switch supplied by others). Freeze protection switch (IF1) input for chilled/hot water (Temp. switch supplied by others). Freeze protection switch (IF2) input for cooling water (Temp. switch supplied by others). Exhaust fan control output. Exhaust fan interlock. tower sump level switch (LS).

11 Dimensions (CH-MG Series) SIDE Front Rear Left Right 2.0 CLEARANCE (IN) 115 (Note 4) NOTES: 1. All pipe connections are ANSI Class 150 flanges. 2. indicates anchor bolt location. 3. Ensure that minimum clearance space is provided for chiller-heater maintenance (length 40 in., above 40 in. and sides 28 in.). 4. Provide maintence clearance for tube removal in front (preferred) or rear of chiller-heater (H) (W) FRONT VIEW Vent Cap CH-MG (L) 2.3 TOP VIEW Exhaust vent flange 62.2 RIGHT SIDE VIEW 3.5 Field wiring junction box water inlet 5 flange Gas inlet 2 flange Condensate drain 1/2 tube REAR VIEW holes 10 mm dia. EXHAUST VENT FLANGE DETAILS Connect Class B venting system to exhaust vent flange for indoor installations water outlet 5 flange Chilled/hot water outlet 4 flange Chilled/hot water inlet 4 flange SIDE Front Rear Left Right 2.0 CLEARANCE (IN) 115 (Note 4) NOTES: 1. All pipe connections are ANSI Class 150 flanges. 2. indicates anchor bolt location. 3. Ensure that minimum clearance space is provided for chiller-heater maintenance (length 40 in., above 40 in. and sides 28 in.). 4. Provide maintence clearance for tube removal in front (preferred) or rear of chiller-heater (H) FRONT VIEW 77.2 (W) 58.5 Vent Cap CH-MG (L) 2.3 TOP VIEW Exhaust vent flange 62.2 RIGHT SIDE VIEW Field wiring junction box water inlet 6 flange Gas inlet 2 flange EXHAST VENT FLANGE DETAILS Connect Class B venting system to exhaust vent flange for indoor installations Condensate drain 1/2 tube 10 holes 10 mm dia. water outlet 6 flange Chilled/hot water outlet 5 flange Chilled/hot water inlet 5 flange REAR VIEW All dimensions in inches

12 YAZAKI SALES REPRESENTATIVE/DISTRIBUTOR For information concerning sales, operation, application or technical assistance, please contact your Yazaki Sales Representative/Distributor or the following: YAZAKI ENERGY SYSTEMS, INC. 701 E. PLANO PARKWAY, SUITE 305, PLANO, TEXAS Phone: Fax: Web: Yazaki reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. SB-MGUL-1107

Gas-Fired Double-Effect Chiller-Heater

Gas-Fired Double-Effect Chiller-Heater Gas-Fired Double-Effect Chiller-Heater CH-K Series: 30, 40, 50, 60, 80, 100 RT Cooling with Standard Heating Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas-Fired Double-Effect Chiller-Heater

More information

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER GUIDE SPECIFICATIONS 150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER HEATER 1. General Description The Contractor shall furnish and install (Qty) Yazaki model CH- Gas Fired,

More information

Water-Fired Chiller/Chiller-Heater. WFC-S Series: 5, 10, 20, 30 and 50 RT Cooling

Water-Fired Chiller/Chiller-Heater. WFC-S Series: 5, 10, 20, 30 and 50 RT Cooling Water-Fired Chiller/Chiller-Heater WFC-S Series: 5, 10, 20, 30 and 50 RT Cooling Water-Fired SINGLE-EFFECT Chiller or Chiller-Heater Yazaki Water-Fired SINGLE-EFFECT chillers have cooling capacities of

More information

DOUBLE EFFECT ABSORPTION CHILLER /HEATER MG MODEL 1

DOUBLE EFFECT ABSORPTION CHILLER /HEATER MG MODEL 1 DOUBLE EFFECT ABSORPTION CHILLER /HEATER MG MODEL 1 Specifications CH-MG150CE CH-MG200CE Version 9.10 Contents Page 1. General Information 1.1 Chiller-heater... 2 1.1.1 Chiller-heater Specification. 2

More information

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER OPERATING INSTRUCTIONS CH-MG150 CH-MG200 GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER FOR YOUR SAFETY If you smell gas: 1. Open windows (only if installed indoors) 2. Don t touch electrical switches

More information

WATER FIRED SINGLE-EFFECT ABSORPTION CHILLER AND CHILLER-HEATER

WATER FIRED SINGLE-EFFECT ABSORPTION CHILLER AND CHILLER-HEATER OPERATING INSTRUCTIONS WFC-SC10, 20, 30 WFC-SH10, 20, 30 WATER FIRED SINGLE-EFFECT ABSORPTION CHILLER AND CHILLER-HEATER This product is a water fired absorption unit which provides chilled water for cooling

More information

SYSTEM DESIGN REQUIREMENTS

SYSTEM DESIGN REQUIREMENTS P a g e 1 SYSTEM DESIGN REQUIREMENTS WFC-S SERIES WATER-FIRED SINGLE-EFFECT ABSORPTION CHILLERS / CHILLER-HEATERS Yazaki WFC-S Series water-fired chillers and chiller-heaters are available with nominal

More information

100 RT CH-K SERIES GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

100 RT CH-K SERIES GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER GUIDE SPECIFICATIONS 100 RT CH-K SERIES GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER 1. General Description The Contractor shall furnish and install (QTY) Yazaki model CH-K100 Gas-Fired, Double-Effect

More information

30 80 RT K-SERIES GAS-FIRED, DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

30 80 RT K-SERIES GAS-FIRED, DOUBLE-EFFECT ABSORPTION CHILLER-HEATER GUIDE SPECIFICATIONS 30 80 RT K-SERIES GAS-FIRED, DOUBLE-EFFECT ABSORPTION CHILLER-HEATER 1. General Description The Contractor shall furnish and install (QTY) Yazaki model CH-K Gas-Fired, Double- Effect

More information

Product Data. Features/Benefits. 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller. 100 to 700 Nominal Tons

Product Data. Features/Benefits. 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller. 100 to 700 Nominal Tons Product Data 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller 100 to 700 Nominal Tons Carrier-Sanyo s 16TJ single-effect hermetic absorption liquid chiller is an efficient and functional alternative

More information

Guide Specifications

Guide Specifications Guide Specifications Hot Water fired Adsorption Liquid Chillers Bry-Air Adsorption Chiller Overview The chiller shall be a Bry-Air ADC series. The chiller shall consist of a robust, compact, packaged chiller

More information

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION GB/T-191-2 to ISO91/2 16TJ 11-53 Nominal cooling capacity 352-2461 kw The Carrier Corporation has more than 1 years experience in providing

More information

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER OPERATING INSTRUCTIONS CH-K30, 40, 50, 60, 80, 100 GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER This product is a gas-fired absorption unit which provides chilled water for cooling or hot water for

More information

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION GB/T-191-2 to ISO91/2 16TJ 11-53 Nominal cooling capacity 352-2461 kw The Carrier Corporation has more than 1 years experience in providing

More information

DOUBLE EFFECT ABSORPTION CHILLERS

DOUBLE EFFECT ABSORPTION CHILLERS DOUBLE EFFECT ABSORTION CHILLERS STEAM CONSUMTION RATE3.9kg/(hUSRt) 3.95kg/(hUSRt) Model in this catalog is our model code. MODEL REW is; The double effect chiller is high efficiency model, The chiller

More information

16LJ Single-Effect Hot Water-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

16LJ Single-Effect Hot Water-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw Single-Effect Hot Water-Fired Absorption Chillers SUPER ABSORPTION GB/T-191-2 to ISO91/2 16LJ 11-53 Nominal cooling capacity 264-1846 kw The Carrier Corporation has more than 1 years experience in providing

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Start-Up, Operation, and Maintenance Instructions

Start-Up, Operation, and Maintenance Instructions 16DF013-050 Hermetic Absorption Liquid Chillers/Heaters Start-Up, Operation, and Maintenance Instructions Absorption liquid chillers/heaters provide safe and reliable service when operated within design

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Product Data. Features/Benefits. 16JT Double-Effect Hermetic. Absorption Liquid Chillers Provide. With Product Integrated Controls (PIC)

Product Data. Features/Benefits. 16JT Double-Effect Hermetic. Absorption Liquid Chillers Provide. With Product Integrated Controls (PIC) Product Data 16JT Double-Effect Hermetic Absorption Liquid Chiller With Product Integrated Controls (PIC) Nominal 100 to 1700 Tons (352 to 5980 kw) Carrier s 16JT Double-Effect Hermetic Absorption Liquid

More information

Thermachill Absorption Chillers

Thermachill Absorption Chillers Thermachill Absorption Chillers Thermachill Two-Stage Direct-Fired Absorption Chillers 100-1100 Tons October 2004 Features and Benefits Thermachill Absorption Chillers The Thermachill direct-fired absorption

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Residential/Commercial Gas Condensing Tankless Models

Residential/Commercial Gas Condensing Tankless Models 15-Year Residential/1-Year Commercial Heat Exchanger Limited Warranty/5-Year Parts Warranty* FEATURES Ultra-Low NOx Condensing Technology Provides Unprecedented.95 Energy Factor Durable Heat Exchanger

More information

Product Data. Features/Benefits. 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz

Product Data. Features/Benefits. 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz Product Data 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz 108 to 680 Nominal Tons (380 to 2392 kw) Carrier s 16JB single effect hermetic absorption liquid chiller offers

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating The High Efficiency AYF60-119 units are 2 module appliances; each AYF is

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU/h high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw T-16DNH-0806-01E DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER : 1350 USRt Heating Capacity: 374 3370 kw Carrier makes the world a better place to live by creating a comfortable, productive and healthy

More information

Installation, start-up use and maintenance manual

Installation, start-up use and maintenance manual Installation, start-up use and maintenance manual GA Line AYF 60-119 Model Air cooled absorption chiller-heater to product chilled water down to 37.4 F and hot water up to 185 F Natural gas/lpg fired INDEX

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

Method to test HVAC equipment at part load conditions

Method to test HVAC equipment at part load conditions IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking

More information

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Tankless Condensing High Efficiency Water Heaters with Built-In Pump Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented

More information

Technical Development Program

Technical Development Program Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger is constructed of HRS35 Commercial-Grade

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using

More information

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER INSTALLATION INSTRUCTIONS CH-K30 CH-K80 with G Series Control Package GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER This product is a gas-fired double-effect absorption unit which provides chilled

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable

More information

Triton Series High Efficiency Boiler

Triton Series High Efficiency Boiler Triton Series High Efficiency Boiler AJAX BOILER INC. Triton Series High Efficiency Boiler The new Atlas Triton Series boilers perform dependably and quietly, offering the most cost effective solutions

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling GAHP is the acronym for Gas Absorption Heat Pump. The GAHP-W is a high efficiency water-cooled heat pump, utilizing

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Residential Gas Tankless Water Heater

Residential Gas Tankless Water Heater CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to a 0.95 Uniform Energy Factor (UEF) which lowers operating costs

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

ClearFire - Hydronic Startup Report

ClearFire - Hydronic Startup Report ClearFire - Hydronic Startup Report Date Serial No. THIS FORM IS FOR MODEL CFC / CFW CLEARFIRE BOILERS Customer s Name Location Model Design Pressure Working Pressure Rated Input (nameplate rating) BTU/hr

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment. SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor

More information

Technical Catalog SAB-LW Series Single Effect Double Lift Hot Water Driven Absorption Chiller 65 to 1,300 Nominal Tons (229 to 4,571 kw)

Technical Catalog SAB-LW Series Single Effect Double Lift Hot Water Driven Absorption Chiller 65 to 1,300 Nominal Tons (229 to 4,571 kw) Technical Catalog SAB-LW Series Single Effect Double Lift Hot Water Driven Absorption Chiller 65 to 1,300 Nominal Tons (229 to 4,571 kw) 1 SAB-LW, Single Effect Double Lift Hot water driven absorption

More information

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU Unmatched Efficiency and Low-NOx Technology in a Condensing Boiler The ClearFire -C is a completely

More information

Tankless Condensing High Efficiency Water Heaters

Tankless Condensing High Efficiency Water Heaters Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented.95 Uniform

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: Brute NEOTHERM Date: Project #: Hydronic Boiler Hydronic Boiler Indoor Sizes 285-850 Submittal Data Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Electronic PID

More information

Absorption Chiller Heat Pump

Absorption Chiller Heat Pump For Future Energy & Environment - KTL KITECH World Energy bsorption Chiller Heat Pump CONTENT Features / Control Sytstem / bsorption Cycle 2 1 Double Effect Exhaust Gas Driven bsorption Machine 12 2 Single

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL Rep: A. Supply and install modulating and condensing boiler(s) as specified herein. Date:

More information

Heat Pumps COMFORT NEED IT. When You

Heat Pumps COMFORT NEED IT. When You Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

FEATURS HYUNDAI CLIMATE CONTROL CO., LTD.

FEATURS HYUNDAI CLIMATE CONTROL CO., LTD. FEATURS 1. Direct-fired absorption chiller-heater gives both heating and cooling. 2. The high efficiency associated with the absorption chilling system has reduced the space required for installation.

More information

LQ AQ SQ. Air-cooled and water-cooled portable chillers

LQ AQ SQ. Air-cooled and water-cooled portable chillers LQ AQ SQ Air-cooled and water-cooled portable chillers Choose from a complete line of dependable Accuchiller portable chillers LQ Series AQ Series SQ Series No other manufacturer can offer you a larger

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

RECORD SUBMITTAL COVER SHEET

RECORD SUBMITTAL COVER SHEET RECORD SUBMITTAL COVER SHEET PROJECT TITLE: AXCELLERATE PHARMA EQUIPMENT DESCRIPTION: CARRIER AQUASNAP AIR-COOLED CHILLER CH-1 OWNER: AXCELLERATE PHARMA MECHANICAL ENGINEER: ARDEN DATE: JUNE 27, 2014 SUBMITTED

More information

GAS ABSORPTION HEAT PUMP

GAS ABSORPTION HEAT PUMP G A H P VV GAS ABSORPTION HEAT PUMP Water Cooled Gas Fired Absorption Heat Pump > Make a choice to build up the future G A H P VV GAS ABSORPTION HEAT PUMP WATER COOLED GAS FIRED ABSORPTION HEAT T PUMP

More information

LQ AQ SQ. Air-cooled and water-cooled portable chillers

LQ AQ SQ. Air-cooled and water-cooled portable chillers LQ AQ SQ Air-cooled and water-cooled portable chillers Choose from a complete line of dependable Accuchiller portable chillers LQ Series AQ Series SQ Series No other manufacturer can offer you a larger

More information

Model YPC ParaFlow Two-Stage Direct-Fired Absorption Chiller-Heaters Style A

Model YPC ParaFlow Two-Stage Direct-Fired Absorption Chiller-Heaters Style A FORM 155.17-EG4 (1108) Model YPC ParaFlow Two-Stage Direct-Fired Absorption Chiller-Heaters Style A Models YPC DF 12SC through YPC DF 19S 200 through 675 Tons 703 kw through 2372 kw Table of Contents FORM

More information