Installation Instructions

Size: px
Start display at page:

Download "Installation Instructions"

Transcription

1 Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK (24- AND 0-KW) CLIP LATCH COVER (OMITTED ON -KW) Fig. Installation of -, 24-, and 0-kw Model Heaters A9054 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing heating and air conditioning equipment can be hazardous due to system pressures and electrical components. Only trained personnel should install or service heating and air conditioning equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on air conditioning equipment, observe precautions in the literature, on tags, and on labels attached to the unit. Form: AG-FAEH-0 Cancels: AG-FB4A-04 Printed in U.S.A. -94 Catalog No. 92-FA-EH

2 INSERT BOX TAB HERE -CIRCUIT GROUND LUG COVER PLATE OR KNOCKOUT BOX TAB DIMPLE BOX DUAL-CIRCUIT GROUND LUG HEATER/CUTOUT COVER COVER WIRE TIE (REMOVE ON LARGE FAN COILS) Fig. 2Installation of Fused Model Heater A905 GROUND LUG CIRCUIT GROUND LINE SIDE CONNECTION BLOWER SHELF FAN COIL COVER PLATE WIRE ROUTING LOAD SIDE MOUNTING BRACKET WIRES TO HEATER WIRE TIE (REMOVE ON LARGER UNITS) Fig. Installation of Circuit Breaker Model Heater A905 2

3 INSULATION # SCREWS SLIDE BEZEL FLANGES UNDER INSULATION BACK OF PANEL Fig. 4Installation of Bezel for Circuit Breaker Model Heater A902 Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. WARNING: Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. TAG THE DISCONNECT SWITCH WITH A SUITABLE WARNING LABEL. Electrical shock can cause personal injury or death. INTRODUCTION This instruction describes the installation of KFAEH accessory heaters in 2 fan coil designs and in the FK4 Fan Coils. The first design found in products manufactured before April 994 (week 494), has a large Texas Instruments printed-circuit board (PCB) with low-voltage terminal board with fan connections on the terminal board. The second design, manufactured after March 994 (week 94), has a small PCB, pigtails, and a wire harness. NOTE: The manufacturing date is approximated. Examine each product and compare to the description above to determine which design is being modified. PROCEDURE INSTALL ELECTRIC HEATER ASSEMBLY INSTALLATION NOTE: Ensure heater coils are not deformed or damaged during heater installation.. Make sure power to unit is off. 2. Remove blower access panel of fan coil unit. CAUTION: Before installation of heater, the black and yellow pigtail leads must be removed from the fan coil PCB or wire harness to prevent possible damage to the product. Electrical power will be provided to the board through the heater circuit plug.. Disconnect 2 power wires (black and yellow pigtail leads) from PCB or wire harness and discard. Wires may be part of a plug assembly or attached to terminals L and L2. Remove cooling control plate from fan coil. For -, 24-, and 0-kw heaters, remove adapter plate. (See Fig..) 4. Insert heater assembly into front of fan coil so that element rods engage holes in heat shield. 5. Attach heater control plate to fan coil using 2 screws. For -, 24-, and 0-kw heater models, attach front of heater to fan deck using third screw. (See Fig..) PROCEDURE 2ATTACH BOX OR CIRCUIT BREAKER BOX. For 5- and 20-kw fused models: After installing heater assembly, attach fuse assembly to side of fan coil unit by inserting fuse box tab between insulation and to left side of unit and fan deck. Mount front of assembly to side flange with 2 screws provided. On fan coil units size 042 and larger, remove wire tie that shortens wire length between heater and fuses. Fuse cover is closed by engaging dimples in fuse box. (See Fig. 2.) 2. For 24- and 0-kw fused models: Fuse assembly is mounted on heater. Be sure fuse cover is closed by engaging clip latch on unit top panel. (See Fig..)

4 ELECTRIC HEATER PART NO. KFAEH00N0 KFAEH20C0 KFAEH020N05 KFAEH0C05 KFAEH00N0 KFAEH40C0 KFAEH040N0 KFAEH50C0 KFAEH050F5 KFAEH0C5 KFAEH0S5 KFAEH00F20 KFAEH70C20 KFAEH90S20 KFAEH09 KFAEH005 KFAEH090 KFAEH00F24 KFAEH0F0 KFAEH200S24 KFAEH20S0 Field convertible to phase. DESCRIPTION kw, Non-fused kw, Circuit Breaker 5 kw, Non-fused 5 kw, Circuit Breaker kw, Non-fused kw, Circuit Breaker 0 kw, Non-fused 0 kw, Circuit Breaker 5 kw, Fused 5 kw, Circuit Breaker 5 kw, Fused (CSA) 20 kw, Fused 20 kw, Circuit Breaker 20 kw, Fused (CSA) 9 kw, Non-fused 5 kw, Non-fused kw, Non-fused 24 kw, Fused 0 kw, Fused 24 kw, Fused (CSA) 0 kw, Fused (CSA) Table Accessory Heater Usage MODEL FA, FB Phase MODEL FC MODEL FH MODEL FK 0, A , Phase Only Phase, Factory Shipped , , 004 A002, A00 B00, B00 A B00-00 A B00-00 A B00-00 A B00-00 A002-00, B00-00 A002-00, B00-00 A002-00, B00-00 A005, A00 B00 Table 2FK4A Minimum CFM for Electric Heater Application FK FAN COIL HEATER KW Refer to unit Installation Instructions to select motor speed. CAUTION: injury or death. Ensure fuse box is closed before power is turned to ON position. Electrical shock may cause personal. For - through 20-kw circuit breaker models: After installing heater assembly, attach circuit breaker assembly to unit with screws provided. (See Fig..) On fan coil units size 042 and larger, remove wire tie that shortens wire length between heater and circuit breaker assembly to allow mounting of circuit breaker assembly. (See Fig..) Circuit breaker models require a bezel be installed in unit door to provide safe access to circuit breakers. Bezel mounts on outside of door with 2 No. screws provided. (See Fig. 4.) PROCEDURE MAKE ELECTRICAL CONNECTIONS Refer to unit instructions for recommended wiring procedures. Install wiring in accordance with all applicable local and national codes. (See Table.) Connect heater wiring harness plug to receptacle on PCB or wire harness. A positive connection must be made between plug and receptacle. Plug will interlock with receptacle when properly seated. Harness contains both 24-v control and high-voltage wiring. NOTE: s with or without electric heaters require a minimum CFM. Refer to unit wiring label to ensure the fan speed selected with electric heaters is equal to or greater than the minimum fan speed indicated. The minimum CFM for cooling is determined by the outdoor unit requirements. Use the higher of the 2 for year-round operation. A. Wire 24-v Control Systems. Connections to unit Use No. AWG color-coded, insulated (5 C minimum) wire to make the low-voltage connections between the thermostat, fan coil unit, and outdoor unit. If the thermostat is located more than 00 ft from the unit (as measured along the low-voltage wire), use No. AWG color-coded, insulated (5 C minimum) wire. All wiring must be separated from line voltage power leads. Refer to outdoor unit wiring instructions for additional wiring procedure recommendations. 2. Transformer 4

5 ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT HEATER PART NO. KFAEH00N0 KFAEH20C0 KFAEH020N05 KFAEH0C05 KFAEH00N0 KFAEH40N0 KFAEH09 KFAEH040N0 KFAEH50C0 KFAEH050F5 KFAEH0S5 KFAEH0C5 KFAEH005 KFAEH090 KFAEH00F20 KFAEH90S20 KFAEH70C20 KFAEH00F24 KFAEH200S24 KFAEH0F0 KFAEH20S0 KW 240V 20V PHASE INTERNAL CIRCUIT PROTECTION CIRCUIT 0.9/ /2.0./20.0./ / /2.0./20..2/40.0.2/ / /59.9./4. 7./ / / /55.4.7/ /55.4.7/ / / / / 20.0 HEATER AMPS 20/20V L, L2 L, L4.2/40.0.2/40.0.2/40.0.2/40.0.2/40.0.2/40.0./20.0./20.0./20.0.2/40.0.2/40.0.2/40.0 CIRCUIT L, L2 L, L4.2/7.5.2/ / / / / / / / /. 74.7/. 4.0/ /5. 97./0. 97./0. 9.5/7.2 / /7.2 / /9.4 4/ /9.4 4/ 57.0 MIN AMPACITY 20/20V 52.2/ / / / / / / / / / / /50.0 MIN WIRE (AWG) 20/20V CIRCUIT L, L2 L, L / /2 / /00 40/ MIN GND WIRE 20/20V CIRCUIT L, L2 L, L /0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 0/0 /CKT BKR AMPS 20/20V CIRCUIT L, L2 L, L /0 25/0 45/50 45/50 5/5 0/0 0/0 0/90 0/90 50/50 0/0 00/0 00/0 70/0 25/50 70/0 25/50 90/00 50/75 90/00 50/75 0/0 0/0 0/0 0/0 0/0 0/0 25/25 25/25 25/25 50/50 50/50 50/50 MAX WIRE LENGTH 20/20V (FT) CIRCUIT L, L2 L, L4 /5 /5 /2 /2 /2 /2 0/ 7/79 7/79 /7 /7 7/2 94/95 4/0 4/0 /7 2/ /7 2/ 20/2 4/45 20/2 4/45 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 7/79 5/5 5/5 5/5 FIELD MULTIPOINT WIRING OF 24- AND 0-KW PHASE HEATER PART NO. KFAEH00F24 KFAEH200S24 KW HEATER AMPS 20/20V MIN AMPACITY 20/20V MIN WIRE (AWG) 20/20V /CKT BKR AMPS 20/20V MAX WIRE LENGTH 20/20V (FT) 240V 20V PHASE L/L2 L/L4 L5/L L/L2 L/L4 L5/L L/L2 L/L4 L5/L L/L2 L/L4 L5/L L/L2 L/L4 L5/L / / / /4.9./40.0./40.0 MIN GND WIRE 20/20V 0 45/50 40/45 40/45 /2 7/7 7/7 KFAEH0F0 KFAEH20S /40.0.2/40.0.2/ / / / /0 50/0 50/0 7/79 5/5 5/5 Circuit Breaker Includes blower motor amps of largest fan coil used with heater. CSA fused with single-point wiring adaptor. Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured way along wire path between unit and service panel for a voltage drop not to exceed 2%. The 24- and 0-kw heaters are convertible to -phase, single or multiple supply circuit. NOTE: Single circuit application of F5 and F20 heaters requires single-point wiring kit accessory. Table Electric Heater Data A 5

6 SECONDARY PRIMARY RED C BRN R BLU RED BLK DC AUX AUX2 F4 F T T2 T L2 EAC2 L EAC F2 F Fig. 5Connection of Transformer Before April 994 A954 SECONDARY BRN RED C YEL BLK PRIMARY Transformer is factory wired for 20-v operation. For 20-v applications (manufactured before week 494), connect transformer red primary lead to T2 and connect blue primary lead to T. (See Fig. 5.) To convert to 20v on products manufactured after week 94, disconnect the black wire on the transformer 20-v terminal and reconnect it to the 20-v terminal. (See Fig..) The secondary circuit of the transformer is protected by a 5-amp fuse mounted on the PCB in both designs. CAUTION: If W2, W, and E are individually connected on any sequencer heater (24, 0, kw), as with outdoor thermostats or any other situation, an emergency heat relay must be used. This relay is in kit KHAOT020SEC and is normally used with kit KHAOT00FST for 2 outdoor thermostat systems.. Heater staging Fig. Connection of Transformer After March 994 Both designs are shipped circuited for single-stage operation. On products manufactured before week 494, staging or outdoor thermostats require breaking tabs off the PCB as needed and the installation of an accessory outdoor thermostat kit. (See Fig. 7.) On products manufactured after week 94, use outdoor thermostat kit KHAOT020SECT for 2-stage operation, and use both kit KHAOT020SEC and KHAOT00FST for -stage operation. When 2-stages are desired, cut W at the W2 wire nut, strip and reconnect per the thermostat kit instruction. (See Fig..) a. The -, 5-, - and 0-kw heaters are single stage only. b. The 9-, 5-, and 20-kw heaters are adaptable for 2-stage operation. c. The -, -24, and 0-kw heaters are adaptable for up to -stage operation. A9407

7 L R C G Y E O W2 W PRINTED CIRCUIT BOARD W2-W JUMPER 2ND STAGE W2-E JUMPER RD STAGE 5-AMP 24-VOLT Fig. 7Jumper Tabs on Printed-Circuit Board A952 B. Power Connections NOTE: Heater supply circuit wire size and overcurrent protection must comply with National Electrical Code (NEC) and UL branch circuit requirements. (See Table.) Wires and overcurrent protection, integral to the heater, are not required to meet branch circuit requirements. Internal circuit protection of 0 amps (maximum) is acceptable.. Unprotected heaters: a. The - through 0-kw single phase and 9-, 5-, and -kw -phase heaters can be wired for single-supply circuit only. Supply circuit connects to heater pigtail leads (terminal block on -kw heaters). b. The - through 0-kw single-phase heaters can use a separate field-installed, factory-authorized disconnect kit which installs in fan coil. 2. Circuit breaker heaters: a. The - through 0-kw heaters can be wired for single-supply circuit only. b. The 5- and 20-kw heaters can be wired for dual-supply circuits only.. Fused heaters: a. The 5- and 20-kw heaters can be wired for single- or dual-supply circuits. Single-supply circuit wiring requires a factory-authorized, single-point adapter kit. Canadian models are factory shipped with single-point adapter kit for single-supply circuits. b. The 24- and 0-kw heaters can be wired for single- or multiple-supply circuits. Heaters are factory wired for single circuit phase. To convert heaters to single circuit single phase, disconnect yellow lead from L and connect to L. Disconnect black lead from L and connect to L2. To convert heaters to multiple-supply circuit single phase, remove and discard leads between single-circuit terminal block and fuse block. Remove and discard single-circuit terminal block. Attach L through L power leads as indicated on label next to fuse block. C. Ground Connections WARNING: According to NEC, ANSI/NFPA 70, and local codes, the cabinet must have a uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. Failure to follow this warning could result in an electric shock, fire, or death.. For unprotected or single-circuit heaters, equipment ground connection is provided on fan coil unit. (See Fig. or 2.) 2. For 5- and 20-kw circuit breaker heaters, an additional ground lug is provided on circuit breaker mounting bracket for dual-circuit grounding. (See Fig..). For 5- and 20-kw fused heaters, an additional ground lug is provided on fuse mounting bracket for dual-circuit grounding. (See Fig. 2.) 4. For 24- and 0-kw fused heaters, 2 additional ground lugs are provided for single-phase, multicircuit wiring. (See Fig..) D. Select Fan Speeds. On products manufactured before week 4 of 994, the factory-selected speed tap is connected to terminal F4. Unused fan speed taps are connected to terminals F2 and F. (See Table 4.) Select desired speed and attach to terminal F4. Attach unused speed tap to terminals F2 and F. 2. On products manufactured after week of 994, speed tap selection is done at the fan relay. To change motor speeds, disconnect the fan lead on the relay and replace with the motor speed tap desired. Save the insulating cap and replace on the motor lead that was removed from the relay. Refer to fan coil Installation Instructions for further clarification of speed tap selections. (See Fig..) 7

8 PCB FAN RELAY SPADE INSULATING CAP (2) MOTOR SPEED TAP LEADS 2 OR SPEED TAP TERMINAL COMMON YELLOW WRAPPER FAN DECK Fig. Motor Speed Tap and Fan Relay A940 PROCEDURE 4ATTACH WIRING DIAGRAM AND RATING LABEL Two wiring diagrams are included to cover both fan coil control designs. Select the proper label for the control design in the fan coil and attach it to the blower housing over the existing wiring label. On model FA, FB, FC, and FH units only, completely covering old wiring diagram label. Do not cover wiring label on model FK. Instead attach new heater rating label over existing electrical information rating label located on front access door of fan coil unit. (See Fig. 9.) PROCEDURE 5VERIFY INSTALLATION After completion of heater installation, check wiring to ensure proper connections and routings have been made. Ensure all electrical covers are in place and proper labels have been applied. Reinstall blower access door before turning unit power on.

9 UNIT RATING LABEL ON DOOR HEATER LABEL FROM KIT Fig. 9Heater Rating Label Location A90 Table 4Color Code for Motor Lead Wires FA, FB, FC, FH s MOTOR SPEED TAP Common High Medium Low WIRE COLOR Yellow Black Blue (Factory selected) Red or Blue 9

10 FAN UNIT 00, 002 OUTDOOR UNIT CAPACITY BTUH,000 24,000 0,000,000 Table 5FK4B Airflow Delivery ELECTRIC HEATER KW RANGE LO MED HI LO MED HI LO MED HI LO MED HI Fan Size 004 Outdoor Capacity Btuh,000 24,000 0,000,000 Electric Heater kw Range LO MED HI LO MED HI LO MED HI LO MED HI Fan Size Outdoor Capacity Btuh 24,000 0,000,000 42,000 24,000 0,000,000 42,000 Electric Heater kw Range LO MED HI LO MED HI LO MED HI LO MED HI Fan Size 00 Outdoor Capacity Btuh,000 42,000 4,000 0,000 Electric Heater kw Range LO MED HI LO MED HI LO MED HI LO MED HI Airflow not recommended for heater/system size. NOTES: LO, MED, and HI refer to AC/HP CFM ADJUST jumper selection. HEATER ONLY airflows are not adjustable by the AC/HP CFM ADJUST SELECT jumper. Airflows shown are independent of external static pressure up to 0.5-in. wc and are at standard air conditions. FAN COIL 00, 002, , Table FK4B Minimum CFM for Electric Heater Application HEAT PUMP UNIT HEATER KW , 9, 0 5, 20 24, NOTES: Air conditioner with electric heater application. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per the airflow delivery chart for Electric Heating Modes RESCO P.O. Box 7, Indianapolis, IN r 0 Book/Tab /c, 4/2c Catalog No. 92-FA-EH

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK20AKF/B, EHK15AHN, EHK18AHN, EHK09AKCN, EHK25AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER,

More information

Electric Heat Accessory Installation Instructions

Electric Heat Accessory Installation Instructions Electric Heat Accessory Installation Instructions EBP, EBX, EBV, EBW FVM, FEM, FSM, FSU WARNING Electrical shock hazard. Installation or repairs made by unqualified persons can result in hazards to you

More information

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N)

FUSE COVER CLIP LATCH (OMITTED ON 18-K3N) Installation Instructions Electric Heater Packages KFCEH TE: Read the entire instruction manual before starting the installation. This symbol --4 indicates a change since the last issue. SINGLE-( GROUND

More information

Electric Heat Accessory Installation Instructions

Electric Heat Accessory Installation Instructions Electric Heat Accessory Installation Instructions EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK0AKF/B, EHK15AHN, EHK1AHN, EHK09AKCN, EHK5AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER, WARNING,

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004 Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

FAN UNIT FH4A Sizes 001 thru 004

FAN UNIT FH4A Sizes 001 thru 004 FAN UNIT FH4A Sizes 001 thru 004 PRACTICALITY & PERFORMANCE Reliability, dependability, and great value are built into the FH4A Fan Units. The unit is compact and easy to install, with capacities ranging

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006 Product Data FK4C Direct Expansion Fan Coil Sizes 00 thru 00 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that

More information

WAHL A Product Specifications

WAHL A Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

INTRODUCTION TABLE OF CONTENTS INSTALLATION. NOTE: Read the entire instruction manual before starting the installation. ELECTRICAL SHOCK HAZARD PAGE

INTRODUCTION TABLE OF CONTENTS INSTALLATION. NOTE: Read the entire instruction manual before starting the installation. ELECTRICAL SHOCK HAZARD PAGE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 HEATER PACKAGES... 1 INSTALLATION...

More information

Installation Instructions

Installation Instructions Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm,

More information

Installation Instructions

Installation Instructions H6HK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers IMPORTANT: The instructions included with this heater kit are for installations

More information

FEM4X. Product Specifications FAN COILS /14/15

FEM4X. Product Specifications FAN COILS /14/15 ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS 1 1/2 thru 5 tons Available for environmentally sound R 410A systems Factory installed TXV metering device Sweat connections Aluminum Tube, Aluminum Fin Evaporator

More information

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P.O. Box 245 Syracuse, NY 13211 www.roth-america.com 888-266-7684 Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P/N: 2300100902 Table of Contents: Section

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED

More information

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

REM4P, REM4X. Product Specifications

REM4P, REM4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT REM4P, REM4X Product Specifications FAN COILS ALL MODELS 2 thru 5 tons Available for environmentally sound R 410A systems Factory installed piston metering device with

More information

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006 Product Data FK4D Direct Expansion Variable Speed Fan Coil Sizes 001 thru 006 A02332 FK4D Premium Air Handling Technology The FK4D is the latest in air handling technology. It is the perfect unit when

More information

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Furnace Control Tester KGACT0201 Table 1 Kit Contents DESCRIPTION PART NO. QUANTITY Furnace Control Tester KGACT0201 1 Adapter Harness 320742-301 1 Installation

More information

Installation Instructions

Installation Instructions CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits Light Commercial Package A/C and Heat Pump Systems Description Installation of 208/240V and 480V H5HK 3 Phase Heater Kits in 6, 7.5 and

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models MB08B1500A2 MB12F1900A2 MB16J2200A2 MB20N2600A2 Contents 115 Volt General Information / Installation... 2 Installations... 3 Horizontal Installations... 3 Ductwork Connections...

More information

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3 DIRECT EXPANSION FAN COIL MODEL FK4C Sizes 001 thru 006 FK4C Premium Air Handling Technology The FK4C is the latest in air handling technology. It is the perfect unit when you need a fan coil that can

More information

Installation Instructions

Installation Instructions HHK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers! IMPOTANT: The instructions included with this heater kit are for installations

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 HEATER PACKAGES... 1 INSTALLATION...

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

FXM4X. Product Specifications FAN COILS FXM4X

FXM4X. Product Specifications FAN COILS FXM4X ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Copper

More information

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FXM4X Product Specifications FAN COILS FXM4X 1 1/2 thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed ECM motor Sweat

More information

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used

More information

Dimensions H x W x D in. (mm)

Dimensions H x W x D in. (mm) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Model Series Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

Installation Instructions

Installation Instructions Installation Instructions Manufactured Housing Blower Package for Electric Furnaces KMABA----TE KMABA----TE NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models EBP EBX EBXX(R -410A) CAUTION Use ONLY factory listed electric heaters. Safety Labeling and Signal Words Danger, Warning and Caution The signal words DANGER, WARNING and

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 001 thru 004 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The series fan coils are reliable, dependable, and a great value. These fan coils offer air handling for practical,

More information

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal Product Data 40FKA Comfort Heat Pump System Fan Coil Sizes 002 thru 006 THERMIDISTAT CONTROL OUTDOOR TEMPERATURE SENSOR 40FKA FAN COIL Comfort Heat Pump System Fan Coil and Thermidistat Control Revolutionizing

More information

Installation Instructions

Installation Instructions CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the

More information

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

USER'S MANUAL/INSTALLATION INSTRUCTIONS

USER'S MANUAL/INSTALLATION INSTRUCTIONS TM USER'S MANUAL/INSTALLATION INSTRUCTIONS P Series Single Package Convertible Air Conditioner Single Package Convertible Air Conditioner IMPORTANT These instructions are primarily intended to assist qualifi

More information

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO. wiring diagrams AIR-COOLED CONDENSING UNIT 566D Sizes 120-240 Cancels: New WD 566D.120.1 11/15/96 UNITS PRODUCED AFTER JANUARY, 1996 INDEX UNIT 566D 120-240 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) SCHEMATIC

More information

Electric Heat Accessory

Electric Heat Accessory Electric Heat Accessory AMFK05CHA AMFK05CHB AMFK07CHA AMFK07CHB AMFK0CHA AMFK0CHB AMFK4CHB AMFK20CHB AMFK25CHB AMFK30CHB Single Phase For Use ith Blower & Fan Coil Units and Electric Furnaces ANING Electrical

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006 Product Data FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant Sizes 002 thru 006 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4A the most advanced air handler available.

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560) ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS FXM4X Product Specifications FXM4X 1½ thru 5 tons Available for Environmentally Sound R 410A systems TXV metering device factory installed High Efficiency, 3

More information

Installation Instructions

Installation Instructions Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...

More information

Owners Manual/Installation Instructions

Owners Manual/Installation Instructions Downflow, Upflow Electric Furnaces Owners Manual/Installation Instructions E Series (Air Conditioner/Heat Pump Air Handler) IMPORTANT: Read this owner information to become familiar with the capabilities

More information

Owners Manual/Installation Instructions

Owners Manual/Installation Instructions Downflow, Upflow Electric Furnaces Owners Manual/Installation Instructions E Series (Air Conditioner/Heat Pump Air Handler) IMPORTANT: Read this owner information to become familiar with the capabilities

More information

SM Field Installed Electric Heat Kit

SM Field Installed Electric Heat Kit SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation

More information

Installation Instructions

Installation Instructions Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 1---1/2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting the

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

Installation Instructions

Installation Instructions HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS For 13 SEER SJ, PAC R-22 Packaged Air Conditioners JP, PHP R-22 Packaged Heat Pumps NM, NL R-410A Packaged

More information

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P APATMENT FAN COIL UNIT FMA4X, FMA4P NOTE: ead the entire instruction manual before starting installation. These instructions must be read and understood completely before attempting installation. TA BLE

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

PF1MNB. Sizes 018m071

PF1MNB. Sizes 018m071 Installation Instruction Direct Expansion Sizes 018m071 Fan Coil Units PF1MNB NOTE: Read the entire instruction manual be_bre starting the installation. This symbol -_ indicates a change from the last

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

Installation Instructions

Installation Instructions NAHB00501WK Twinning Kit for HSI Single-Stage Condensing and Non-Condensing Gas Furnaces Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace WARNING Improper installation, adjustment, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

Owners Manual/Installation Instructions

Owners Manual/Installation Instructions Downflow, Upflow Electric Furnaces Owners Manual/Installation Instructions EEH-xxx HB Series EEB-xxx HB Series (Air Conditioner/Heat Pump Air Handler) IMPORTANT: Read this owner information to become familiar

More information

Owners Manual/Installation Instructions

Owners Manual/Installation Instructions Downflow, Upflow Electric Furnaces Owners Manual/Installation Instructions EEH-xxx HB Series EEB-xxx HB Series (Air Conditioner/Heat Pump Air Handler) IMPORTANT: Read this owner information to become familiar

More information

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT SERVICE UNIT INFORMATION Corp. 9311 L2 B24 Litho U.S.A. The B24 blower units are designed for multi-position installation with add-on C22FC/CR22/CH22 or C24FC/ CR24/CH24 series coil sections. The B24 may

More information

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS WARNING: THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UN- SATISFACTORY OPERATION OR DAMAGE

More information

USER'S MANUAL/INSTALLATION INSTRUCTIONS

USER'S MANUAL/INSTALLATION INSTRUCTIONS TM USER'S MANUAL/INSTALLATION INSTRUCTIONS P Series Single Package Convertible Air Conditioner Single Package Convertible Air Conditioner IMPORTANT These instructions are primarily intended to assist qualifi

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information