Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G

Size: px
Start display at page:

Download "Solar regulator DIEMASOL C. Installation and Service Manual. User Guide G"

Transcription

1 EN Solar regulator DIEMASOL C Installation and Service Manual User Guide G

2 . Copyright All sections of these instructions for installation and use are protected by copyright. Any use likely to breach the copyright requires permission from De Dietrich. This includes reproduction / copies, translation, transfer to microfilm and storage in electronic systems. Important note The text and illustrations in these instructions have been produced with the greatest care and desire for accuracy. However, since errors may have escaped our notice, your attention is drawn to the following points: Your projects must be based entirely on your own calculations and plans, produced in accordance with current regulations. We do not accept any responsibility for the completeness of the illustrations or text in these instructions; they simply provide examples. The use or application of the information given is the sole responsibility of the person concerned. The publisher cannot be held responsible for any inadequate, incomplete or erroneous information or any losses arising from such. With the reservation that there may be errors and/or technical modifications. Safety instructions Please read the following installation and commissioning instructions carefully before operating your equipment. You will thus avoid the risk of damage arising from incorrect operation of your system. Note also that the installation must take into account the configuration of the building. The installation and commissioning must be carried out professionally. Comply with current regulations. Also follow advice for the prevention of accidents issued by accident insurance companies. Incorrect use or unauthorised modifications to the installation or the equipment itself invalidate any right to claim. Location With regard to the location, please comply with Dietrisol instructions. Work on the equipment Installation, commissioning, maintenance and repairs must be carried out by authorised specialists (approved heating engineers / installers). Before any work is carried out on the equipment / heating system, the power supply must be disconnected (by means of the appropriate fuse or main switch, for example) and warning must be given before any reconnection. The electricity must be disconnected via a circuit breaker that isolates all non-earthed cables from the mains by a gap of at least 3 mm between the contacts. For any work involving the dismantling of the regulator, check that the internal components are not likely to cause a static electricity discharge. Repair work Repair work on components relevant to safety is not permitted. Commissioning Commissioning should be carried out by the system manufacturer or a specialist approved by him; the measured values must be recorded in a report. Information for the user The system manufacturer must supply the user with an instruction document and explain to him how the system operates. 2 DIEMASOL C 27/10/ G

3 Contents. 1 Description Diemasol C solar regulator Package list Technical characteristics Installation Mounting Electrical connection Relays and terminals for sensors Types of sensors Operation Adjustment keys Language selection / Changing the settings LED message code General description of how the unit operates General view of the systems Solar system operating mode Additional functions Choosing the system Parameters /10/ G DIEMASOL C 3

4 1. Description 1 Description Dietrisol solar installations are fitted with Diemasol C type regulators. These regulators are of the "smart" solar type. They are self-contained and able to determine the optimum regulation for the system ("matched flow") according to tank temperatures and solar collector temperatures. After rinsing and refilling, the solar installations equipped with Diemasol settings do not require any further adjustment. Moreover, these regulators can load and unlaod a storage tank (DMCDB) and control the swimming pool pump and/or a biomass boiler. 1.1 Diemasol C solar regulator The Diemasol C solar regulator combines all the basic functions required and is also suitable for east-west fields of collectors and 2- tank systems. The new Diemasol C regulator can handle a QUADRO, an additional storage tank or a swimming pool and a biomass boiler. Moreover, it has a bus outlet as standard, which can be used to check the service condition of the solar installation using special software or perform remote consultations by means of a modem. 1.2 Package list Diemasol C FKP6 collector sensor 2.5 m silicon cable (x1) DHW sensor with FRP150 sensor tube PUR 2.5 m cable (x2) FRP6 flow sensor with PUR 2.5 m cable (x1) Accessories bag (x1) (x1) 1.3 Technical characteristics Box: plastic, polycarbonate / ABS, polymethylmethacrylate (PMMA). Class of protection: IP 20 / DIN Ambient temperature: C Dimensions: 172 x 110 x 46 mm Type of mounting: Wall mounting Display: 160 x 64 pixel graphic display in 16 shades of grey Controls: via 3 keys on the front panel Storage temperature: C Range of measurement: C Inputs: 11 Pt1000 temperature sensors Outputs: 9 relay outputs Max. total switching intensity: 4 VA Power supply: V (AC), Hz Power consumption: approx. 2 VA 4 DIEMASOL C 27/10/ G

5 2 Installation 2. Installation 2.1 Mounting The device must be installed inside the building in a dry place. For perfect operation the device must also be installed in a location free from powerful electromagnetic fields. It must be possible for the regulator to be isolated from the mains by a circuit breaker that provides at least a 3 mm gap between all the poles or by a circuit breaker that conforms to installation standards. When installing, take care to fit the power supply cable and the sensor wires separately. Before dismantling anything, take care to disconnect the unit from the mains. 1. Mark the mounting point on the wall and fit the dowel supplied and the matching screw without tightening it. 2. Remove the Phillips screw from the cover and separate the cover from the unit by pulling it downwards. 3. Hang the unit from the upper mounting point. Mark the lower mounting point on the wall (160 mm drilling template), see the back of the base frame, then fit the lower dowel. 4. Hang the unit by the top and tighten the lower screw. 1 Top cover 2 Alphanumeric LCD display 3 Control keys 4 Terminal blocks 5 Base 6 Cable clamps 7 Sub-cover 8 Cover 9 LED 27/10/ G DIEMASOL C 5

6 2. Installation 2.2 Electrical connection The regulator must be supplied with electricity at a voltage of V ( Hz) via an external switch (final step!). The cables must be clamped in the unit's cable clamps by tightening the screws provided. Electromechanic relay Semiconductor 0 1 IMP C Sensor terminals 2 Terminal block earth 3 T6.3 A fuse 4 Terminal block user components 5 Terminal mains 6 Terminal block neutral 7 Terminal block earth 8 Connection for the flowmeter 9 VBus connection terminals 2.3 Relays and terminals for sensors The regulator is fitted with 9 relays to which the following components are connected: Relay 1 (primary circuit pump, speed control) Relay 2 (secondary circuit pump, speed control) Relay 3 (Reversal valve domestic hot water tank zones) Relay 4 (Biomass boiler pump) Relay 5 (MCDB reversal valve) Relay 6 (Collector valve 1 east-west) Relay 7 (Collector valve 2 east-west) Relay 8 (MCDB unloading pump, swimming pool pump) Relay 9 (DHW pump MCDB) The temperature sensors ( to 1) are connected to the following terminals (SX and GND): 1 sensor (Solar collector temperature sensor, TC) 2 sensor (Flow temperature, Thermal plate exchanger, TE) 3 sensor (Domestic hot water tank temperature 1 lower zone, TS) 4 sensor (Domestic hot water tank temperature 1 upper zone / Domestic hot water tank temperature 2 lower zone, TM) 5 sensor (Domestic hot water tank temperature 1 central zone / Domestic hot water tank temperature 2 central zone) 6 sensor (Domestic hot water tank temperature 2 lower zone) 7 sensor (Domestic hot water tank temperature 2 upper zone) 8 sensor (Biomass boiler temperature) 9 sensor (Collector temperature 2) 10 sensor (Input temperature heat meter) 11 sensor (Output temperature heat meter) 6 DIEMASOL C 27/10/ G

7 3 Types of sensors 3. Types of sensors The Diemasol C regulator uses very accurate temperature sensors (Pt1000 model) (FKP and FRP). The range includes 3 types of sensors to fit all installations: - a dip probe - a flat-surface-mounted sensor - a pipe-mounted sensor. The FKP and FRP sensor types are similar from a technical point of view and the models are similar.only their electrical connections are different: FK: 1.5 m silicone sensor cable, resistant to weather variations and temperature variations, designed for temperatures of -50 C C, designed for the collector. FR: Ölflex 2.5 m cable for use at temperatures between +5 C and +80 C, intended for the DHW tank. Comply with current regulations. The sensor cables carry a low voltage; they should not be in the same cable duct as cables carrying more than 50 volts. The length of the sensor cable can be extended to 100 m. The section of the extension must be 1.5 mm 2 (or 0.75 mm 2 for lengths up to 50 m). For longer lengths or when using cable ducts, it is preferable to use twisted-core cables. For dip probes, use sensor tubes. FKP6: Pt1000 temperature sensor, diameter 6 mm, 1.5 mm silicone sensor cable, temperature range C, no sensor tube, sensor incorporated in the collector. FRP150: Pt1000 temperature sensor, immersion depth 150 mm, copper sensor tube (nickel-plated), complete sensor to be incorporated in the tank. To avoid the risk of voltage surge in the collector sensor (for example, due to a nearby lightning conductor), we recommend that you install a De Dietrich SP1 surge protection system 27/10/ G DIEMASOL C 7

8 4. Operation 4 Operation 4.1 Adjustment keys Capteur 70,6 C M001321_01 The regulator is controlled by the 3 keys only located below the display. The right-hand key 1 (>) takes you to the next menu or increases the adjustment values. The left-hand key 2 (<) does the opposite. The adjustment parameters are displayed after the measured values. To access these parameters, press and hold the right-hand key for 3 sec. from parameter tc. When the display shows an adjustment parameter, the word SEt appears. Then simply press the middle key 3 (SET) to set the value. 1. Select the required parameter using keys 1 and Press the 3 key: The word SEt flashes. 3. Adjust the value using keys 1 and Press the 3 key: The set value is stored. The word SEt stops flashing. Graphic display The graphic display is divided into 2 zones: 1. Display of the schematic selected and visualisation of the display and settings parameter chosen using flashing symbols. 2. Display of the parameters on two lines for the menus and values, and settings parameters. 4.2 Language selection / Changing the settings To set the language on the regulator, proceed as follows: 1. In the initial display, press key 1 several times to scroll through the parameters until the last one. 2. Press key 1 again and hold it down for around three seconds until this new screen is displayed. 3. Select the Language menu in the list using the 1 key. 4. To confirm, press the 3 key. The language currently programmed is displayed. 5. Change the language by pressing keys 1 or Press the 3 key to confirm the setting. 7. To go back to the initial display, press key 2 several times. To modify the other settings, consult the description of the parameters, see chapter LED message code Continuously green At least one relay is closed Continuously red All relays are open Flashing green/red - Initialisation phase - Sensor fault - Manual mode - Maximum tank temperature exceeded 8 DIEMASOL C 27/10/ G

9 5. General description of how the unit operates 5 General description of how the unit operates The Diemasol C regulator is capable of controlling a multitude of thermal solar installations and other additional functions (biomass boiler and swimming pool pump, MCDB). Here are the various installation schematics possible: 5.1 General view of the systems C /10/ G DIEMASOL C 9

10 5. General description of how the unit operates 5.2 Solar system operating mode solar systems with thermal plate exchanger, solar end C QUADRO 750 QUADRO HFS 750 MF/ FWS 750 MF + DKC PSB + DKC RSB + DKCS The sun's rays heat the transfer fluid in the collector. To trigger the regulation process, a minimum temperature of 30 C () on the collector and an activation temperature difference of 10 K compared with the domestic hot water tank () must be reached. In the ensuing auto-calibration phase (auto-calibration period setting parameter, factory setting 3 minutes), the solar pump () operates at full power (100%). Subsequently, by means of a dynamic speed control system for the primary and secondary circuit pump, an attempt is made to reach a target temperature difference (reference T, factory setting 20 C). The secondary pump switches on for a period of 2 minutes (). From that moment, measuring the temperature and running the programme is no longer done by the sensor located in the solar power logger, but is done by the sensor located on the exchanger output. The tank zone reversal temperature is reached in a variable manner which depends on the temperature on the flow sensor () and the temperature in the upper section of the tank (). When the minimum reversal temperature (factory setting 40 C) is exceeded on the flow sensor () and the temperature in the upper section of the tank () is colder than the temperature measured on the flow sensor (), the reversal valve () is activated in the upper part of the tank (preparation of solar drinking water). Depending on the heat available, the system heats up the solar tank and cuts off when the tank storage temperature is reached (adjustment parameter Tballon1max, factory setting: 60 C). When the collector reaches its maximum temperature (adjustment parameter Tcapt1max, factory setting: 100 C), the solar pump responsible for cooling the system switches on and operates until the temperature is 5 K less than parameter Tcapt1max or until the maximum storage temperature (80 C) is exceeded. As soon as the temperature in the collectors drops below the temperature in the calorifier, the calorifier is cooled down to its set temperature. The amount of heat transferred from the collectors to the tank is displayed as parameter AH. The value is cumulative and is constantly updated. 10 DIEMASOL C 27/10/ G

11 solar systems with 2 smooth-piped thermal exchangers, solar end 5. General description of how the unit operates QUADRO 500 C The sun's rays heat the transfer fluid in the collector. To trigger the regulation process, a minimum temperature of 30 C () on the collector and an activation temperature difference of 10 K compared with the domestic hot water tank () must be reached. In the ensuing auto-calibration phase (auto-calibration period setting parameter, factory setting 3 minutes), the solar pump () operates at full power (100%). Subsequently, by means of a dynamic speed control system for the primary and secondary circuit pump, an attempt is made to reach a target temperature difference (reference T, factory setting 20 C). The tank zone reversal temperature is reached in a variable manner which depends on the collector temperature and the temperature in the upper part of the tank. When the minimum reversal temperature (factory setting 40 C) is exceeded on the collector sensor and the temperature in the upper part of the tank is colder than the temperature measured on the flow sensor, the reversal valve () is activated in the upper part of the tank (preparation of solar drinking water). Depending on the heat available, the system heats up the solar tank and cuts off when the tank storage temperature is reached (adjustment parameter Tballon1max, factory setting: 60 C). When the collector reaches its maximum temperature (adjustment parameter Tcapt1max, factory setting: 100 C), the solar pump responsible for cooling the system switches on and operates until the temperature is 5 K less than parameter Tcapt1max or until the maximum storage temperature (80 C) is exceeded. As soon as the temperature in the collectors drops below the temperature in the calorifier, the calorifier is cooled down to its set temperature. The amount of heat transferred from the collectors to the tank is displayed as parameter AH. The value is cumulative and is constantly updated solar systems with thermal plate exchanger, solar end, and east-west collector field C The operating mode is identical to that of solar systems. Only the two collector fields can operate independently of each other. In this scenario, two additional 2-way valves ( and ) are tripped. The valves control either the first or second, or both collector fields. When the activation temperature difference between a collector field and the tank of 10 K is reached, the corresponding 2-way valve opens and the tank can be loaded. QUADRO 750 QUADRO HFS 750 MF/ FWS 750 MF + DKC PSB + DKC RSB + DKCS 27/10/ G DIEMASOL C 11

12 5. General description of how the unit operates solar systems with 2 tanks or 1 tank and 1 swimming pool with / without thermal plate exchanger, solar end 2 tanks with / without DKC (S) 1 tank and 1 swimming pool with / without DKC (S) C The operating mode for installations with 2 users for heating is identical to that of systems as far as the first user is concerned (exception: no action in the drinking water zone in the upper part of tank 1). The regulator compares the collector temperature with the temperature in tank 2 or the swimming pool. If the temperature difference measured is greater than the parameter values for the activation temperature difference ( T2on), the pump is started up and loaded via the reversal valve in tank 2 or the swimming pool until the maximum temperature set at most (Ttank2max). With the parameter (priority, factory setting tank 1), priority must be given to one of the two tanks. Heating in parallel is not possible. If tank 1 is loaded or the temperature conditions for loading are not satisfied but the temperature conditions for loading tank 2 or swimming pool 2 are satisfied, the reversal valve is bypassed. Loading is done for 15 minutes (t-change, factory setting). Loading of tank 2 or the swimming pool is suspended for 2 minutes (t-pause, factory setting) and the regulator monitors the increase in temperature on the collector. If the temperature on the collector increases by 2 K in the space of 2 minutes (fixed value), the 2 minutes are zeroed and the regulator restarts the countdown from the beginning. If the activation conditions for tank 1 are satisfied, loading starts immediately, otherwise loading of tank 2 or the swimming pool continues. If tank 1 has reached its maximum temperature, only tank 2 or the swimming pool are loaded. Given that, because of the configuration chosen for the installation (swimming pool), the solar thermal exchanger may be too small in tank 1, if the solar energy is too high, this may lead to overheating on the solar system due to the fact that the solar energy available in the tank can no longer be transferred. To obviate this, there is a regulator criterion which compares the collector temperature with the temperature in tank 1. If the collector temperature is 40 C higher than the tank temperature, the switch is made automatically to tank 2 or the swimming pool in order to cool down the solar system. It is possible to use a DKC or DKCS station during activation of the parameter on the external thermal plate exchanger. 12 DIEMASOL C 27/10/ G

13 5. General description of how the unit operates solar systems with 2 tanks or 1 tank and 1 swimming pool with / without thermal plate exchanger, solar end, and east-west collector field 2 tanks with / without DKC (S) 1 tank and 1 swimming pool with / without DKC (S) C The operating mode is identical to that of solar systems. Only the two collector fields can operate independently of each other. In this scenario, two additional 2-way valves ( and ) are tripped. The valves control either the first or second, or both collector fields. When the activation temperature difference between a collector field and the tank of 10 K is reached, the corresponding 2-way valve opens and the tank can be loaded. It is possible to use a DKC or DKCS station during activation of the parameter on the external thermal plate exchanger. 27/10/ G DIEMASOL C 13

14 5. General description of how the unit operates 5.3 Additional functions Tubular solar collector function The tubular solar collector function can be activated in all schematics. If the regulator observes an increase of 2 K compared with the last collector temperature recorded, the solar pump is activated at 100% for 30 seconds to calculate the current temperature of the fluid. Once the running time of the solar pump is over, the current collector temperature is recorded as a new point of reference. If the temperature calculated (new point of reference) is again exceeded by 2 K, the solar pump is tripped again for 30 seconds. If, during the running time of the solar pump or even on shutdown of the installation, the activation difference between the collector and the tank is exceeded, the regulator automatically switches to solar loading. If the collector temperature drops by 2 K during shutdown, the activation point for the tubular collector function is recalculated. Cooling the system The solar installation is deactivated when the maximum tank parameter temperature is reached. If the collector temperature increases to reach the maximum collector parameter temperature, the solar pump is activated for as long as necessary for the value to fall back down below this temperature limit. The tank temperature may rise again (maximum temperature of the secondary active tank), but only until it reaches 80 C (tank safety deactivation). If the tank temperature is higher than the maximum tank temperature and the collector temperature is lower than the tank temperature by at least 5 K, the solar installation continues to operate until the tank has again been cooled down via the collector and the pipes to below the maximum tank parameter temperature. External thermal plate exchanger It is only possible to activate a thermal plate exchanger in the solar part with 2-tank systems. The operating mode is the same as with QUADRO 750. It is possible to use 2 storage tanks without a thermal spiral tube exchanger with a thermal plate exchanger. Systems with 1 storage tank without a thermal spiral tube exchanger and 1 swimming pool can be regulated in this way. The thermal plate exchanger and the additional pump are not displayed by the regulator. Heat meter A heat meter can be installed at the solar end with all solar systems. There are two implementation options: Option 1: Preset for all systems, the option is used to accurately calculate the quantity of heat transmitted. A flow rate, estimated by the regulator, and the collector temperature and the temperature in the lower part of the tank are used for the calculation. The estimated flow rate is adapted by the regulator according to the pump rotation speed. For systems with 2 tanks, it is the sensor in the lower section of the tank being loaded which is used. The maximum flow rate must be set by the installer on start up of the solar regulator. See table below: Collector surface Number of Flow rate (l/h) Flow rate (l/ (m 2 ) panels min) < x x x The actual value is generally slightly lower or higher than the calculated value of the quantity of heat. Option 2: The option must also be activated and is used to calculate the exact quantity of heat. It is also necessary to order package EG 174: Flow meter with 2 temperature sensors. To this end, the heat meter parameter must be set in the parameters menu to select the flow rate measuring component. Indicate a pulse rate which corresponds to the flow rate measuring component used V40. The two temperature sensors must be connected to the regulator via sensor terminals 0 and 1. Sensor 0 must be placed at the solar flow and sensor 1 at the solar return. The flow meter must be installed at the coldest solar return end. 14 DIEMASOL C 27/10/ G

15 5. General description of how the unit operates MCDB Pool C B AB A 2 C Unloading of the mixed tank (1) is done when the temperature of the mixed tank () is hotter than the minimum load temperature (min. load temp.) and the temperature difference is between and (unload.- Ton) (pump activated and three way valve on A/AD). If the temperature difference between and (Unload.- Toff) is less than 3 C, unloading is deactivated. If the mixed tank (1) is cooled down by an energy draw-off and the temperature difference between and (Load.- Ton) is at least 10 C, loading of the mixed tank (1) is done ( activated and three way valve on B/AB). The swimming pool load pump () is activated when the temperature of tank (min. tank T) rises to at least 40 C and a temperature difference between and ( Ton) of 10 C is reached. The pump is deactivated when the temperature difference between and ( Toff) is less than 3 C and the temperature of the swimming pool (max. pool T) is higher than 30 C. Biomass C The tank load pump () is activated when the minimum boiler temperature (min. boil. temp.) of 60 C is exceeded and the temperature difference between and ( Ton) is more than 10 C. The load pump is deactivated when the temperature difference between and ( Toff) is less than 3 C and the maximum tank temperature (max. tank temp.) of 80 C is reached. 27/10/ G DIEMASOL C 15

16 6. Choosing the system 6 Choosing the system 1.0 System C Secondary solar pump, rotation speed regulated (P2) Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) 1.1 System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Biomass boiler temperature 16 DIEMASOL C 27/10/ G

17 6. Choosing the system 1.2 System C Secondary solar pump, rotation speed regulated (P2) MCDB reversal valve MCDB unloading pump DHW pump MCDB Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone 1.3 System C Secondary solar pump, rotation speed regulated (P2) Swimming pool pump Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Pool temperature 27/10/ G DIEMASOL C 17

18 6. Choosing the system 1.4 System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump MCDB reversal valve MCDB unloading pump DHW pump MCDB Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone Biomass boiler temperature 1.5 System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump Swimming pool pump Sensor inlet 0 1 Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Pool temperature Biomass boiler temperature 18 DIEMASOL C 27/10/ G

19 6. Choosing the system 2.0 System C Sensor inlet 0 1 Description 2.1 System C Biomass boiler pump Sensor inlet 0 1 Description Domestic hot water tank temperature 1 central zone Biomass boiler temperature 27/10/ G DIEMASOL C 19

20 6. Choosing the system 2.2 System C Sensor inlet Description MCDB reversal valve Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone MCDB unloading pump DHW pump MCDB System C Sensor inlet Description Domestic hot water tank temperature 1 central zone Pool temperature Swimming pool pump DIEMASOL C 27/10/ G

21 6. Choosing the system 2.4 System C Biomass boiler pump MCDB reversal valve MCDB unloading pump DHW pump MCDB Sensor inlet 0 1 Description Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone Biomass boiler temperature 2.5 System C Biomass boiler pump Swimming pool pump Sensor inlet 0 1 Description Domestic hot water tank temperature 1 central zone Pool temperature Biomass boiler temperature 27/10/ G DIEMASOL C 21

22 6. Choosing the system 3.0 System C Secondary solar pump, rotation speed regulated (P2) Collector valve 1 east-west Collector valve 2 east-west Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Collector temperature System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump Collector valve 1 east-west Collector valve 2 east-west Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Collector temperature DIEMASOL C 27/10/ G

23 6. Choosing the system 3.2 System C Secondary solar pump, rotation speed regulated (P2) MCDB reversal valve Collector valve 1 east-west Collector valve 2 east-west MCDB unloading pump DHW pump MCDB Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone Collector temperature System C Secondary solar pump, rotation speed regulated (P2) Collector valve 1 east-west Collector valve 2 east-west Swimming pool pump Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Pool temperature Collector temperature /10/ G DIEMASOL C 23

24 6. Choosing the system 3.4 System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump MCDB reversal valve Collector valve 1 east-west Collector valve 2 east-west MCDB unloading pump DHW pump MCDB Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Domestic hot water tank temperature 2 lower zone Domestic hot water tank temperature 2 upper zone Biomass boiler temperature Collector temperature System C Secondary solar pump, rotation speed regulated (P2) Biomass boiler pump Collector valve 1 east-west Collector valve 2 east-west Swimming pool pump Sensor inlet Description Thermal plate exchanger: Flow temperature (TE) Domestic hot water tank temperature 1 central zone Pool temperature Biomass boiler temperature Collector temperature DIEMASOL C 27/10/ G

25 6. Choosing the system 4.0 System C Sensor inlet Description Inverter valve Tank (V1) Domestic hot water tank temperature 2 lower zone (TM) System C / Sensor inlet Description Inverter valve Tank (V1) Pool temperature /10/ G DIEMASOL C 25

26 6. Choosing the system 4.2 System C Biomass boiler pump Sensor inlet 0 1 Description Domestic hot water tank temperature 2 lower zone (TM) Domestic hot water tank temperature 2 central zone Biomass boiler temperature 4.3 System C Inverter valve Tank (V1) MCDB reversal valve MCDB unloading pump DHW pump MCDB Sensor inlet 0 1 Description Domestic hot water tank temperature 2 central zone Domestic hot water tank temperature 3 lower zone Domestic hot water tank temperature 3 upper zone 26 DIEMASOL C 27/10/ G

27 6. Choosing the system 5.0 System C Inverter valve Tank (V1) Collector valve 1 east-west Collector valve 2 east-west Sensor inlet Description Domestic hot water tank temperature 2 lower zone (TM) Collector temperature System C Inverter valve Tank (V1) Collector valve 1 east-west Collector valve 2 east-west Sensor inlet Description Pool temperature Collector temperature /10/ G DIEMASOL C 27

28 6. Choosing the system 5.2 System C Biomass boiler pump Collector valve 1 east-west Collector valve 2 east-west Sensor inlet Description Domestic hot water tank temperature 2 lower zone (TM) Domestic hot water tank temperature 2 central zone Biomass boiler temperature Collector temperature System C Inverter valve Tank (V1) MCDB reversal valve Collector valve 1 east-west Collector valve 2 east-west MCDB unloading pump DHW pump MCDB Sensor inlet Description Domestic hot water tank temperature 2 lower zone (TM) Domestic hot water tank temperature 2 central zone Domestic hot water tank temperature 3 lower zone Domestic hot water tank temperature 3 upper zone Collector temperature DIEMASOL C 27/10/ G

29 7 Parameters 7. Parameters 7.1 Schematics Name Schematics Factory setting Min Max Explanations General Self cal. time [min] x x x x x x Vent duration Min. changeov. t. x x x x x x Minimum reversal temperature, load upper tank TReference x x x x x x Target temperature difference - Ttank1max x x x x x x Maximum tank temperature Tcol1max x x x x x x Maximum collector temperature min. speed x x x x x x Min. rotation speed, pump 1 min. speed x x x x x x Min. rotation speed, pump 2 Tubular solar panel x x x x x x no no yes Tubular collector option MCDB Loading- Ton x x Ton - Mixed tank load - Loading- Toff x x Toff - Mixed tank load - Loading min. Temp. x x Minimum load temperature, mixed tank Unloading- Ton x x Ton - Unloading mixed tank - Unloading- Toff x x Toff - Unloading mixed tank - Pool Min. temp. tank x x Minimum tank temperature Max. temp. pool x x Maximum swimming pool temperature Ton x x Activation temperature difference - Toff x x Deactivation temperature difference - Biomass Min. temp. Boiler x x x Minimum biomass boiler temperature Max. temp. tank x x x Not active Maximum tank temperature Ton x x x Activation temperature difference - Toff x x x Deactivation temperature difference - Heat meter Flow meter x x x x x x no no yes Option V40 Max. flow x x x x x x Maximum volume Flow/Imp. (x) (x) (x) (x) (x) (x) Pulse rate Time x x x x x x 12:01 00:00 23:59 Time Date x x x x x x Date 27/10/ G DIEMASOL C 29

30 7. Parameters 7.2 Schematics Name Schematics Factory setting Min Max Explanations General Self cal. time [min] x x x x x x Vent duration Min. changeov. t. x x x x x x Minimum reversal temperature, load upper tank TReference x x x x x x Target temperature difference - Ttank1max x x x x x x Maximum tank temperature Tcol1max x x x x x x Maximum collector temperature min. speed x x x x x x Min. rotation speed, pump 1 Tubular solar panel x x x x x x no no yes Tubular collector option MCDB Loading- Ton x x Ton - Mixed tank load - Loading- Toff x x Toff - Mixed tank load - Loading min. Temp. x x Minimum load temperature, mixed tank Unloading- Ton x x Ton - Unloading mixed tank - Unloading- Toff x x Toff - Unloading mixed tank - Pool Min. temp. tank x x Minimum tank temperature Max. temp. pool x x Maximum swimming pool temperature Ton x x Activation temperature difference - Toff x x Deactivation temperature difference - Biomass Min. temp. Boiler x x x Minimum biomass boiler temperature Max. temp. tank x x x Not active Maximum tank temperature Ton x x x Activation temperature difference - Toff x x x Deactivation temperature difference - Heat meter Flow meter x x x x x x no no yes Option V40 Max. flow x x x x x x Maximum volume Flow/Imp. (x) (x) (x) (x) (x) (x) Pulse rate Time x x x x x x 12:01 00:00 23:59 Time Date x x x x x x Date 30 DIEMASOL C 27/10/ G

31 7. Parameters 7.3 Schematics Name Schematics Factory setting Min Max Explanations General Self cal. time [min] x x x x x x Vent duration Min. changeov. t. x x x x x x Minimum reversal temperature, load upper tank TReference x x x x x x Target temperature difference - Ttank1max x x x x x x Maximum tank temperature Tcol1max x x x x x x Maximum collector temperature 1 Tcol2max x x x x x x Maximum collector temperature 2 min. speed x x x x x x Min. rotation speed, pump 1 min. speed x x x x x x Min. rotation speed, pump 2 Tubular solar panel x x x x x x no no yes Tubular collector option MCDB Loading- Ton x x Ton - Mixed tank load - Loading- Toff x x Toff - Mixed tank load - Loading min. Temp. x x Minimum load temperature, mixed tank Unloading- Ton x x Ton - Unloading mixed tank - Unloading- Toff x x Toff - Unloading mixed tank - Pool Min. temp. tank x x Minimum tank temperature Max. temp. pool x x Maximum swimming pool temperature Ton x x Activation temperature difference - Toff x x Deactivation temperature difference - Biomass Min. temp. Boiler x x x Minimum biomass boiler temperature Max. temp. tank x x x Not active Maximum tank temperature Ton x x x Activation temperature difference - Toff x x x Deactivation temperature difference - Heat meter Flow meter x x x x x x no no yes Option V40 Max. flow x x x x x x Maximum volume Flow/Imp. (x) (x) (x) (x) (x) (x) Pulse rate Time x x x x x x 12:01 00:00 23:59 Time Date x x x x x x Date 27/10/ G DIEMASOL C 31

32 7. Parameters 7.4 Schematics Name Schematics Factory setting Min Max Explanations General Self cal. time [min] x x x x Vent duration Min. changeov. t. x x x x Minimum reversal temperature, load upper tank T1on x x x Activation temperature difference 1 T1off x x x Deactivation temperature difference 1 T2on x x x Activation temperature difference 2 T2off x x x Deactivation temperature difference 2 Ttank1max x x x x Maximum tank temperature Ttank2max x x x x Maximum tank temperature 2 Tcol1max x x x x Maximum collector temperature min. speed x x x x Min. rotation speed, pump 1 min. speed Min. rotation speed, pump 2 (If external thermal plate (x) (x) (x) (x) exchanger activated) Tubular solar panel x x x x no no yes Tubular collector option MCDB Loading- Ton x Ton - Mixed tank load - Loading- Toff x Toff - Mixed tank load - Loading min. Temp. x Minimum load temperature, mixed tank Unloading- Ton x Ton - Unloading mixed tank - Unloading- Toff x Toff - Unloading mixed tank - Biomass Min. temp. Boiler x Minimum biomass boiler temperature Max. temp. tank x Not active Maximum tank temperature Ton x Activation temperature difference - Toff x Deactivation temperature difference - Heat meter Flow meter x x x x no no yes Option V40 Max. flow x x x x Maximum volume Flow/Imp. (x) (x) (x) (x) Pulse rate Priority x SP 1 SP 1 SP 2 Tank priority t-break x 2:00 1:00 30:00 Alternated break time t-change x 15:00 3:30 30:00 Alternated load time Ext. heat exchanger (x) (x) (x) (x) no no yes Ext. thermal exchanger, solar system Time x x x x 12:01 00:00 23:59 Time Date x x x x Date 32 DIEMASOL C 27/10/ G

33 7. Parameters 7.5 Schematics Name Schematics Factory setting Min Max Explanations General Self cal. time [min] x x x x Vent duration Min. changeov. t. x x x x Minimum reversal temperature, load upper tank T1on x x Activation temperature difference 1 T1off x x Deactivation temperature difference 1 T2on x x Activation temperature difference 2 T2off x x Deactivation temperature difference 2 TReference x x Target temperature difference - Ttank1max x x x x Maximum tank temperature Ttank2max x x Maximum tank temperature 2 Tcol1max x x x x Maximum collector temperature 1 Tcol2max x x x x Maximum collector temperature 2 min. speed x x x x Min. rotation speed, pump 1 min. speed Min. rotation speed, pump 2 (If external thermal plate (x) (x) (x) (x) exchanger activated) Tubular solar panel x x x x no no yes Tubular collector option MCDB Loading- Ton x Ton - Mixed tank load - Loading- Toff x Toff - Mixed tank load - Loading min. Temp. x Minimum load temperature, mixed tank Unloading- Ton x Ton - Unloading mixed tank - Unloading- Toff x Toff - Unloading mixed tank - Biomass Min. temp. Boiler x Minimum biomass boiler temperature Max. temp. tank x Not active Maximum tank temperature Ton x Activation temperature difference - Toff x Deactivation temperature difference - Heat meter Flow meter x x x x no no yes Option V40 Max. flow x x x x Maximum volume Flow/Imp. (x) (x) (x) (x) Pulse rate Ext. heat exchanger (x) (x) (x) (x) no no yes Ext. thermal exchanger, solar system Time x x x x 12:01 00:00 23:59 Time Date x x x x Date 27/10/ G DIEMASOL C 33

34 7. Parameters 34 DIEMASOL C 27/10/ G

35 7. Parameters 27/10/ G DIEMASOL C 35

36 Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 27/10/08 DE DIETRICH THERMIQUE 57, rue de la Gare F MERTZWILLER - BP 30

BSC...E - BSP...E - BESC...E

BSC...E - BSP...E - BESC...E INISOL DUO E DIETRISOL DUO E Solar hot water calorifer BSC...E - BSP...E - BESC...E EN User Guide 0007781-001-01 Contents 1 Introduction.............................................................................

More information

* * EC1. Variable controller for circulation systems Mounting and operation manual

* * EC1. Variable controller for circulation systems Mounting and operation manual variable controller for circulation systems adaptive pump control easy-to-install housing user-friendly operation by simple handling intuitive menu operation via push button Technical data RESOL EC1 Housing:

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual SR868C6 System Regulator for Solar Thermal Systems Display Panel Illustration Pos. Button on display panel Button description 1 Green lamp Power indication lamp 2 On/Off

More information

Operation Manual of Solar controller SR1568 for split solar system

Operation Manual of Solar controller SR1568 for split solar system Operation Manual of Solar controller SR1568 for split solar system Read the instruction carefully please before operation! Contents 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2

More information

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.

More information

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SD2. Differential Controller. Operating and Installation Instructions F2 72.3 SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C SOLNEO EN Gas fired condensing boiler SGC 24 SOL User Guide 300017555-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols and abbreviations................................................................................3

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. US Read

More information

DeltaTherm FK * * Solid fuel boiler controller Manual for the specialised craftsman

DeltaTherm FK * * Solid fuel boiler controller Manual for the specialised craftsman DeltaTherm FK Solid fuel boiler controller Manual for the specialised craftsman Mounting Electrical connection Application examples Operation Troubleshooting *11204753* 11204753 Your mobile remote display

More information

EN Z Subject to change due to technical improvements! Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature differential controller 3 inputs, 1 output These operating instructions are part of the product. Read

More information

Boiler controller S-Tronic Plus

Boiler controller S-Tronic Plus Operating Instructions Boiler controller S-Tronic Plus Version 50.0 - Build 05.0 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A DIEMATIC WALL-MOUNTED CONTROL SYSTEM Electronic control system capable of controlling 2 heating circuits, a DHW circuit and an auxiliary circuit EC identification No.: 0085CM0178 Electronic microprocessor

More information

Boiler controller Lambdatronic S 3200

Boiler controller Lambdatronic S 3200 Operating Instructions Boiler controller Lambdatronic S 3200 Version 50.04 - Build 05.04 Translation of the original German operating instructions for technicians and operators Read and follow the instructions

More information

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions Electronically controlled instantaneous water heater CEX 9-U: 27910-50 C models Installation instructions For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. 1.

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

~ 0 ~ Contents Contents-----------------------------------------------------------------------------------1 1. Safety information ------------------------------------------------------------------3 1.1

More information

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail) 74 319 0400 0 G2484 en Installation Instructions Solar Energy Manager RVP502 Installation Place of installation In a dry room, e.g. in the boiler room Installation choices: - Control panel (in the panel

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 6 2.1 Before you start.....................................................

More information

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers: Valid for item numbers: HPS-C-MULTI 6: 69010.306 (6-zone) 69010.312 (12-zone) 69010.324 (24-zone) 69010.336 (36-zone) HPS-C-MULTI 6 Hotrunner Controllers Operating manual HPS-C-MULTI 6 with WIRE TEST (WT):

More information

TR 0603mc U Solar Controller

TR 0603mc U Solar Controller TR 0603mc U Solar Controller Part #8718572810 Engineering Submittal Sheet 178 mm [7.00 inch] 8 90 mm [3.54 inch] 170 mm [6.69 inch] 170 mm [6.69 inch] 134 mm [5.28 inch] 106 mm [4.17 inch] 32 1.26 0.31

More information

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Our products have been designed and manufactured in such a way to ensure that all quality, functionality and aesthetic requirements

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

3-way switching valve

3-way switching valve Operating Manual UK 3-way switching valve for domestic hot water charging USV 1" AG USV 5/4" AG USV 6/4" IG UK805189 / 201109 Translation of the original instruction manual Please read first This operating

More information

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. SHORT DESCRIPTION: 1. Device is applicable to: - Burners; - Electric boiler;

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Installation instructions

Installation instructions LADDOMAT MR 30 Installation instructions Scope of delivery Sys 30: Art no. 11 34 31 02 Laddomat MR, complete. Spring-loaded non-return valve BV FB40-T Charge pump LM6A-130, with 2 x shut-off valves Cu28

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no Installation instructions for contractors VIESMNN Extension E1 Part no. 7429 151 Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 361 TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Odyssey. issue 01c. system manual

Odyssey. issue 01c. system manual dyssey issue 01c system manual SYSTEM MANUAL Table of Contents Technical Specification 1 Summary of Features 2 General Description 3 Control ptions 4 Description of Main Features 5 Control Schemes 6 Installation

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

Operating instructions

Operating instructions Operating instructions Room controller 6 720 618 477-00.1RS Logamatic EMS RC35 programming unit For users Read carefully before use. 6 720 642 272 (10/2009) GB Overview of controls Overview of controls

More information

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa

More information

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service Service instructions Function module FM443 solar module For contractors Read carefully prior to commissioning or service 6 720 615 516-03/2008 GB/IE Contents 1 Safety........................................

More information

Model: RT510RF. Installation Manual

Model: RT510RF. Installation Manual Model: RT50RF Installation Manual Contents Product compliance... 3 Safety Information... 3 Box content... 3 Introduction... 3 Features... Installation... 5. RXRT50 Receiver... 5 Button Description for

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

User Guide. OPTYMA TM Control Three-phase AK-RC 103

User Guide. OPTYMA TM Control Three-phase AK-RC 103 User Guide OPTYMA TM Control Three-phase AK-RC 103 Table of contents Page General...3 Description...3 Functions and main characteristics...3 Applications...3 Technical characteristics of OPTYMA TM Control

More information

SR-5/2D Solar-Power-Regulator

SR-5/2D Solar-Power-Regulator T self-optimising controller for solar hot water plants SR-5/2D Solar-Power-Regulator European Patent No. 0 880 659 U.S. Patent No. 6.047.696 Canadian Patent 2,249,018 Subject to technical alterations

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. CONTROL PANEL... 9 5.1

More information

RS Pro Infrared Temperature Sensor

RS Pro Infrared Temperature Sensor Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid

More information

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual RESOL AM1 alarm module Mounting Connection Function AM1 alarm module *48005020* 48005020 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O HMC300 Control unit EMS plus 6 720 808 471-00.1O Operating Instructions 6 720 813 192 (2014/10) Contents Contents Key to symbols and safety instructions................3 1.1 Key to symbols...........................

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information

PRELIMINARY EDITION

PRELIMINARY EDITION 3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied

More information

DeltaTherm HC * * Heating controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

DeltaTherm HC * * Heating controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting DeltaTherm HC beginning with version 1.09 Heating controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *11210353* 11210353 Adjust your heating via

More information

Installation and user manual

Installation and user manual Installation and user manual Please read carefully and retain for future reference Models EcoHeat: C3, C5, C6, C8, C9, C11, C12 Rev.1_09-07-15 Page 1 Table of Contents 1 IMPORTANT: WARNINGS 1.1 GENERAL

More information

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER Low pressure with PI-control-mode Manufacturer: Phone: Fax: E-Mail: Website: Issue: Doc.-no.: Arthur Grillo GmbH Am Sandbach

More information

- Data Brochure Mixing Control 360

- Data Brochure Mixing Control 360 - Data Brochure Mixing Control 360 D 360 03/09 The Mixing Control 360 is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The

More information

* * Valves, controls + systems. Regtronic RH Installation and operating instructions for the specialised installer

* * Valves, controls + systems. Regtronic RH Installation and operating instructions for the specialised installer EN Valves, controls + systems Regtronic RH Installation and operating instructions for the specialised installer *11202683* 11202683 Please read this manual carefully to get the best performance from this

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549

More information

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed

More information

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply   - Tel: Systems Index Systems - Systems Systems...1 -.16 General information Description...1 System description...2 Overview...3 Ordering details Arc monitor with detectors...4 Current sensing unit...5 Technical

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

P5253 JS F Mertzwiller N IT /02/2013

P5253 JS F Mertzwiller N IT /02/2013 T Technical Sales Documentation Department Technical information Heading No 5 Wall-hung gas condensing boilers NANEO EMC... - PMC... Service tool / After Sales Service information Package HR83 (option)

More information

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element P500 P500 A P500 AS P500 A WS P500 AS WS A- AirBreak WS Water Softener AS Dual Rinse Element Table of Contents 1. INTRODUCTION... 3 1.1 1.2 1.3 INSTALLATION AND COMMISSIONING... 3 SERVICE AND REPAIRS...

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533

More information

Installation Guide. ECL Comfort 310, application A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................

More information

DOL 31 Speed Controller Technical User Guide

DOL 31 Speed Controller Technical User Guide Technical User Guide For other language variants of this document we refer to your local dealer or http://docs.skov.com/1158. Available from April 2016. 612061 2016.09.20 Technical User Guide Program

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

Operating manual SR988C1 For split pressurized solar hot water system controller

Operating manual SR988C1 For split pressurized solar hot water system controller Operating manual SR988C1 For split pressurized solar hot water system controller Content 1. Safety information... 5 1.1 Installation and commissioning... 5 1.2 About this manual... 5 1.3 Liability waiver...

More information

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode Operating instructions for the system user VIESMANN Heating system with Vitotronic 100 control unit for constant temperature mode VITODENS VITOPEND 4/2007 Please keep safe. Safety instructions For your

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Microgrid Fault Protection Based on Symmetrical and Differential Current Components Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared for Public Interest Energy Research California Energy Commission Prepared by Hassan Nikkhajoei and Robert H.

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

Operating instructions

Operating instructions Operating instructions Solar thermal controller 7747006071-00.1 SD Solar thermal system with Logamatic SC40 For the Owner Please read carefully before operation. 7 747 017 474 GB (2007/08) OSW Contents

More information

Universal tank control WTS Installation and operating instructions for plant engineering companies

Universal tank control WTS Installation and operating instructions for plant engineering companies WELBA Universal tank control WTS-100-2 Installation and operating instructions for plant engineering companies 103497-V026 - by WELBA - 27/11/2018 WELBA GmbH Electronic Control Engineering Gewerbepark

More information

Installation Guide. Twin Kit 086L1370

Installation Guide. Twin Kit 086L1370 086L1370 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather

More information