Price List. BN-PL Jan. 2018

Size: px
Start display at page:

Download "Price List. BN-PL Jan. 2018"

Transcription

1 BN-PL Jan. 2018

2 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page Step-In Unit Coolers Low Profile Unit Cooler See page Walk-In Unit Coolers Refrigerated Warehouse Unit Coolers Section 1 ½ - 6 HP Condensing Units with Micro-channel Coils & VSEC Condenser Fan Motors See page HP Vertical Air Discharge Condensing Units See page Ton Air-cooled Condensers See page Glycol Unit Coolers 104 CO2 Unit Coolers Compressorized Products 113 Air-Cooled Condensing Units 171 Water-Cooled Condensing Units 182 Remote Compressor Units Section PRO3 Packaged Refrigeration Systems Direct Drive Fluid Coolers FN s See page 218 Condensers & Fluid Coolers Lead Lag Temperature Controller See page Air-Cooled Condensers 218 Fluid Coolers More Products & Services Section 3 Condensing Units with Screw Compressors See page Refrigeration Controls & Technology Other Products & Services Section 4 Air-cooled Package Chillers for Process Cooling See page 239 Resources & Information 248 Terms of Sale & Product Warranty Section 5

3 Table of Contents Section I: Reach-In Unit Coolers Thin Profile Air Defrost... 1 Thin Profile Electric Defrost... 2 C Profile... 3 V Profile... 4 Back Bar... 5 Mullion... 6 Reverse Mullion... 7 Twin Flow... 8 Dual Air... 9 Shipped-Loose Accessories Section II: Step-In Unit Coolers Extended Thin Profile s & Options Pricing Shipped-Loose Accessories Section III: Walk-In Unit Coolers Slim Contour Mounted Components s Air Defrost s & Options Electric Defrost s & Options Shipped-Loose Accessories Low Profile Mounted Components s Air Defrost s & Options Electric Defrost s & Options Hot Gas Defrost s & Options Hot Gas Reverse Cycle Kits Hot Gas 3-Pipe Kits Shipped-Loose Accessories Low Flow Air Defrost s & Options Electric Defrost s & Options Hot Gas Defrost s & Options Shipped-Loose Accessories Low Velocity Center Mount Air Defrost s & Options Electric Defrost s & Options Hot Gas Defrost s & Options Shipped-Loose Accessories Center Mount Air Defrost s & Options Electric Defrost s & Options Shipped-Loose Accessories Medium Profile Air Defrost s & Options Electric Defrost s & Options Hot Gas Defrost s & Options Hot Gas Reverse Cycle Kits Shipped-Loose Accessories Section IV: Refrigerated Warehouse Unit Coolers Large Unit Coolers Air Defrost s & Options Electric Defrost s & Options Hot Gas Defrost s & Options Hot Gas Reverse Cycle Kits Shipped-Loose Accessories Section V: Glycol Unit Coolers Low Profile Air Defrost s & Options Electric Defrost s & Options Warm Fluid Defrost s & Options Low Velocity Center Mount Air Defrost s & Options Electric Defrost s & Options Warm Fluid Defrost s & Options Center Mount Air Defrost s & Options Medium Profile Air Defrost s & Options Shipped-Loose Accessories Balance & Shut-Off Valves Section VI: CO2 Unit Coolers Low Profile Air Defrost s & Options Electric Defrost s & Options Low Velocity Center Mount Air Defrost s & Options Electric Defrost s & Options Center Mount Electric Defrost s & Options Medium Profile Air Defrost s & Options Electric Defrost s & Options Section VII: Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories HP Horizontal Air Discharge Standard & Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories HP Horizontal Air Discharge Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories i

4 Table of Contents HP Vertical Air Discharge Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories HP Vertical Air Discharge Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories HP Dual Compressor Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories HP Dual Compressor Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories Section VIII: Water-Cooled Condensing Units ½ - 6 HP Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories ¾ - 22 HP Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories Section IX: Remote Compressor Units ¾ - 22 HP Configurable s Pricing Factory-Installed Options Factory-Installed Electric Defrost Options Shipped-Loose Accessories Section X: PRO3 Packaged Refrigeration Systems Top Mount Standard s Pricing Side Mount Standard s Pricing Section XI: Air-Cooled Condensers 1-26 Ton Configurable s & Options Pricing Ship-Loose Accessories Ton Configurable s Pricing Options Pricing - Rail-Mounted VSEC s Options Pricing - Venturi-Mounted VSEC s 206 Options Pricing - Fixed Speed s Coil Options Pricing - All s Microchannel Condenser Configurable s Pricing Options Pricing VSEC s Options Pricing AC s Section XII: Fluid Coolers FN Fluid Coolers FNH s 1.5 HP 1140 RPM Motors FNL s 1.5 HP 830 RPM Motors FNQ s 0.5 HP 540 RPM Motors FNE s VSEC Motors Options Pricing - VSEC s Options Pricing - FNH/FNL/FNQ s Connections Options - All s Coil Options Pricing - All s Shipped-Loose Accessories Small Fluid Coolers Configurable s & Options Pricing Shipped-Loose Accessories Section XIII: Refrigeration Controls & Technology Beacon II Refrigeration System HyperCore Micro-Channel Coils Remote Refrigeration Control Lead Lag Temperature Controller Split System Controller Section XIV: Other Products & Services Air-Cooled Package Chillers Screw Compressor Condensing Units Heatcraft Commercial Financing Mohave Advanced Hot Gas Defrost System 242 Two Stage Condensing Units & Systems FlexPack Refrigeration Racks Air Handlers Compressor Protection Plan Extended Service Agreements Section XV: Terms of Sales & Product Warranty Terms & Conditions of Sale Catalog Products Warranty Warranty FAQ ii

5 Table of Contents Page left blank intentionally. iii

6 Reach-In Unit Coolers Thin Profile Air Defrost Overview Product Description TA is a thin profile air defrost unit which mounts in the top of a refrigerator and makes the entire top shelf area usable. The attractive low silhouette makes the unit particularly desirable for display type refrigerators. It can also be used in back bars, under counter cabinets, or wherever space is at a premium and is ideal for 35 to 45 F fixtures at 10 to 15 TD applications with 16 hours maximum compressor run time per day. Certifications Standard Features Textured aluminum cabinet Molded Polycarbonate guards and fans Drain fitting mounted at 45 angle so drain can be run through back or bottom of refrigerator Expansion valve can be mounted inside the cabinet Stainless steel screws Motors are thermally protected and permanently lubricated Convenient, moisture proof motor plug Compact design achieves a big job in a small space Internal junction box for electrical connection Sweat inlet connection standard to reduce leaks Options Flare connection available as a ship loose option Optional coated coil available ( TAK) for enhanced protection in corrosive environments Pricing Standard Voltage TA10AG 115/1/ TA10BG /1/ TA13AG 115/1/ TA13BG /1/ TA17AG 115/1/ TA17BG /1/60 1,052 TA23AG 115/1/60 1,254 TA23BG /1/60 1,346 TA30AG 115/1/60 1,558 TA30BG /1/60 1,665 Standard Voltage TA43AG 115/1/60 2,105 TA43BG /1/60 2,251 TA55AG 115/1/60 2,667 TA55BG /1/60 2,853 TAK10AG 115/1/ TAK10BG /1/ TAK13AG 115/1/ TAK13BG /1/60 1,040 TAK17AG 115/1/60 1,103 TAK17BG /1/60 1,182 Section 1 Standard Voltage TAK23AG 115/1/60 1,397 TAK23BG /1/60 1,494 TAK30AG 115/1/60 1,705 TAK30BG /1/60 1,823 TAK43AG 115/1/60 2,313 TAK43BG /1/60 2,476 TAK55AG 115/1/60 2,967 TAK55BG /1/60 3,178 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 1

7 Reach-In Unit Coolers Thin Profile Electric Defrost Overview Section 1 Product Description TL low temperature unit cooler has a completely automatic defrost system. Mounted in the top of a refrigerator, its extremely compact cabinet makes it possible to utilize the entire top shelf area for storage. Having a normal operating range of +20 F. to 20 F., this unit is ideally suited applications including commercial freezers, ice cream boxes, bakery freezers and dual-temp reach-in boxes. Mechanical contact is provided between the heater elements and the drain pan, ensuring a warm pan during the defrost cycle. Opting for EC motors makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Electric defrost ensures positive heat source Built-in fan delay allows coil to be chilled before returning to the normal cooling cycle Defrost terminates on coil temperature eliminating excessive defrost period Textured aluminum cabinet Molded Polycarbonate guard Knockouts provided on sides for electrical connections - opening in rear for coil connections Expansion valve can be mounted inside the cabinet Stainless steel screws Motors are thermally protected and permanently lubricated Internal junction box for electrical connection Plate type aluminum fins with full collars on expanded copper tubes Coils are dehydrated and sealed Easy to install and maintain Sweat inlet connection to reduce leaks All models UL listed for the US and Canada UL classified to NSF standardsdimensional Data Options Flare connection available as a ship loose option EC motors available for some models Pricing Standard Voltage TL09AG 115/1/60 1,088 TL09BG /1/60 1,088 TL12AG 115/1/60 1,308 TL12BG /1/60 1,308 TL16AG 115/1/60 1,617 TL16BG /1/60 1,617 Standard Voltage TL21AG 115/1/60 1,838 TL21BG /1/60 1,838 TL28AG /1/60 2,313 TL28BG /1/60 2,313 TL35BG /1/60 2,609 TL53BG /1/60 3,592 Nomenclature 2 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

8 Reach-In Unit Coolers C Profile Overview Product Description C is ideal for refrigerated reach-ins. It mounts to the top of the refrigerator and discharges cold air against the back wall. With this air flow pattern, the air is not blasted on the product but is diffused along the back wall and then gently drawn across the product as it returns to the unit. Thus, uniform temperatures are maintained throughout the refrigerator. In addition, door sweating and refrigeration loss due to door opening is greatly reduced because the air is not discharged against the doors. Mounting is made easy by means of aluminum hangers that automatically space the unit the correct distance from the back wall. The expansion valve fits inside, out of sight. Opting for EC motors makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Textured aluminum cabinet Molded Polycarbonate guard Drain fitting at 45-degree angle so drain can be run through bottom or back of refrigerator Aluminum hangers automatically space the unit to the correct distance from the back wall Stainless steel screws prevent rust streaks Room for expansion valve inside the unit Knockouts in sides and top plus openings in rear provide maximum flexibility for electrical connection Full collar aluminum fins on expanded copper tubes Internal junction box with pigtail leads for electrical connection Motors are thermally protected and permanently lubricated Sweat inlet connection standard to reduce leaks All models UL listed for US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Optional coated coil available ( CK) for enhanced protection in corrosive environments EC motors available Pricing Standard Voltage C13AG 115/1/ C13BG /1/ C17AG 115/1/ C17BG /1/ C23AG 115/1/60 1,026 C23BG /1/60 1,102 C30AG 115/1/60 1,322 C30BG /1/60 1,470 C43AG 115/1/60 1,652 C43BG /1/60 1,770 Standard Voltage CK13AG 115/1/ CK13BG /1/ CK17AG 115/1/ CK17BG /1/60 1,022 CK23AG 115/1/60 1,103 CK23BG /1/60 1,182 CK30AG 115/1/60 1,526 CK30BG /1/60 1,627 CK43AG 115/1/60 1,968 CK43BG /1/60 2,109 Section 1 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 3

9 Reach-In Unit Coolers V Profile Overview Section 1 Product Description VA is a deluxe unit designed for use in small reach-ins, back bar and under counter refrigerators, and many other applications where a small, compact unit is required. The thermal expansion valve mounts inside the unit. The unit can be mounted from the ceiling or off the back wall or end walls, or can be used in a mullion application. Opting for EC motors makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Textured aluminum cabinet Molded Polycarbonate fan guard Improved drain pan overlaps coil surface to catch all condensate Stainless steel screws prevent rust streaks Plate-type aluminum fins with full collars on expanded copper tubes Expansion valve can be mounted inside the cabinet Internal junction box for electrical connection Pigtail leads in junction box Motors are thermally protected and permanently lubricated Top quality throughout in a compact size Sweat inlet connection standard to reduce leaks All models UL listed for US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Optional coated coil available ( VAK) for enhanced protection in corrosive environments EC motors available for some models s Pricing Standard Voltage VA06AG 115/1/ VA06BG /1/ VA08AG 115/1/ VA08BG /1/ VA12AG 115/1/ VA12BG /1/ VA17AG 115/1/ VA17BG /1/ Standard Voltage VAK06AG 115/1/ VAK06BG /1/ VAK08AG 115/1/ VAK08BG /1/ VAK12AG 115/1/ VAK12BG /1/ VAK17AG 115/1/ VAK17BG /1/60 1,040 Nomenclature 4 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

10 Reach-In Unit Coolers Back Bar Overview Product Description BB, available in medium and low temperature, a compact, wall-mounted units featuring a low height making them ideal for under counter reach-in or drawertype fixtures. The unit draws air in at the bottom and discharges out the front. An optional air deflector is included and can be mounted over the center of the fan to direct air up and out. The deflector can be fieldformed to direct the air where needed, usually onto drop-in trays of condiments in salad bar or sandwich preparation fixtures. An S-type mounting angle is included to position the unit 3/4 off the wall, allowing for optimum air circulation and performance. Certifications Standard Features Molded Polycarbonate fan guards Coils have copper tubes with aluminum fins, mechanically bonded for efficient heat transfer. The coils are dehydrated and sealed Textured aluminum cabinet Knockouts are conveniently located for refrigerant lines Screws are hardened, stainless steel Expansion valve can be mounted inside the cabinet and connections are sweat-type Motors are thermally protected and permanently lubricated Master units include the basic unit plus factory mounted expansion valve, solenoid, and temperature control. Also right-hand piping extended 8-12 outside the housing, sealed and pressurized to PSI. A 1/4 OD liquid feed to slave is included Slave units include the basic unit plus factory mounted expansion valve with left-hand piping extended 8-12 outside the housing, sealed and pressurized to PSI Sweat inlet connection to reduce leaks Options Flare connection available as a ship loose option Consult Factory for V units Pricing Consult factory for V units Standard Voltage BBM11AG 115/1/60 1,139 BBM16AG 115/1/60 1,374 BBMM11AG 115/1/60 2,507 BBMM16AG 115/1/60 2,747 BBMS11AG 115/1/60 2,177 BBMS16AG 115/1/60 2,418 Standard Voltage BBL10AG 115/1/60 1,534 BBL15AG 115/1/60 1,822 BBLM10AG 115/1/60 3,313 BBLM15AG 115/1/60 3,697 BBLS10AG 115/1/60 2,983 BBLS15AG 115/1/60 3,368 Section 1 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 5

11 Reach-In Unit Coolers Mullion Overview Section 1 Standard Features Light grained aluminum cabinets PVC coated fan guard Stainless steel hardware Coils have full collar aluminum fins on expanded copper tubes Coated coil for enhanced protection in corrosive environments Refrigerant connection knockouts provided on both ends of unit Expansion valve can be mounted inside the cabinet Motors are thermally protected and permanently lubricated Internal junction box for electrical connection Adjustable air deflector included provides different air patterns. Air can be directed where it s needed Sweat inlet connection to reduce leaks All models UL listed for the US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Product Description KMK is ideal for under-counter reachin refrigerators. The thin line design allows the unit to be mounted behind the mullion with sufficient clearance for tray slides. A down flow fan arrangement is used with air drawn in at the top and discharged at the bottom. This design provides superior air circulation and ensures uniform temperature throughout the cabinet. This versatile design is also adaptable for mounting on the back wall or ends of a cooler. The method of air circulation ensures minimum box temperature rise when the cabinet doors are open. Ideal for bottled goods and beverage coolers. Pricing Standard Voltage KMK13AG 115/1/60 1,199 KMK13BG /1/60 1,281 KMK17AG 115/1/60 1,450 KMK17BG /1/60 1,549 KMK23AG 115/1/60 1,735 KMK23BG /1/60 1,856 Certifications Nomenclature 6 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

12 Reach-In Unit Coolers Reverse Mullion Overview Standard Features Textured aluminum cabinet PVC coated fan guard Stainless steel hardware Coils have full collar aluminum fins on expanded copper tubes Coated coil for enhanced protection in corrosive environments Refrigerant connection knockouts provided on both ends of unit Expansion valve can be mounted inside the cabinet Motors are thermally protected and permanently lubricated Internal junction box for electrical connection Adjustable air deflector included provides different air patterns. Air can be directed where it s needed Sweat inlet connection standard to reduce leaks All models are UL listed for the US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Section 1 s Pricing Product Description RAMK is ideal for under-counter reach-in refrigerators, under-counter drawer type refrigerators and salad bars. The unit is suitable for mounting behind a mullion or on a wall. An up flow air pattern is used with air drawn in at the bottom and discharged out the top. This provides optimum temperature for drop in trays on salad bars or prep tables. It also keeps drawer stored product in premium condition. An adjustable and detachable air deflector/splash protector is included. The deflector can be adjusted to direct the air up and out at a 45 angle. This feature provides excellent air distribution over drop in trays or containers.food in the trays and containers stays colder, lasts longer, and retains the desired appearance. The deflector can be adjusted to distribute air out both sides when used as a mullion unit. Standard Voltage RAMK13AG 115/1/60 1,199 RAMK13BG /1/60 1,281 RAMK17AG 115/1/60 1,450 RAMK17BG /1/60 1,549 RAMK23AG 115/1/60 1,735 RAMK23BG /1/60 1,856 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 7

13 Reach-In Unit Coolers Twin Flow Overview Section 1 Product Description BTO is a compact two-way design with medium velocity airflow. The unit is mounted flush to the ceiling and draws air in through the fan and discharges out both sides. The air pattern reduces air loss when doors are opened and the medium velocity reduces product drying. Twin flow units are for temperatures of 35 F. and higher. Box temperatures are kept more constant throughout and fresh products last longer. Seven sizes are available with BTUH from 900 to 5500 at 10 TD. Opting for EC motors makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Compact two-way design with medium velocity air flow Mounts flush to the ceiling and draws air in through the fan and discharges out both sides Air pattern reduces air loss when doors are opened and the medium velocity reduces product drying Textured aluminum cabinet Stainless steel fasteners Molded Polycarbonate fan guards Drain pan and fan panel is easily removed for installation and servicing Coils are constructed of copper tubing with aluminum fins Expansion valve can be mounted inside the cabinet Internal junction box is provided for electrical connection Motors are thermally protected and permanently lubricated Sweat inlet connection to reduce leaks All models are UL listed for the US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Optional coated coil available ( BTOK) for enhanced protection in corrosive environments EC motors available for some models Pricing Standard Voltage BTO09AG 115/1/ BTO09BG /1/ BTO13AG 115/1/ BTO13BG /1/ BTO18AG 115/1/60 1,050 BTO18BG /1/60 1,123 BTO25AG 115/1/60 1,292 BTO25BG /1/60 1,376 BTO35AG 115/1/60 1,674 BTO35BG /1/60 1,789 BTO45AG 115/1/60 2,121 BTO45BG /1/60 2,270 BTO55AG 115/1/60 2,693 BTO55BG /1/60 2,883 BTOK09AG 115/1/ BTOK09BG /1/ BTOK13AG 115/1/ BTOK13BG /1/60 1,042 BTOK18AG 115/1/60 1,234 BTOK18BG /1/60 1,322 BTOK25AG 115/1/60 1,522 BTOK25BG /1/60 1,623 BTOK35AG 115/1/60 1,973 BTOK35BG /1/60 2,111 BTOK45AG 115/1/60 2,470 BTOK45BG /1/60 2,642 BTOK55AG 115/1/60 3,068 BTOK55BG /1/60 3,284 Nomenclature 8 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

14 Reach-In Unit Coolers Dual Air Overview Standard Features Textured aluminum cabinet Full collar aluminum fins on expanded copper tubes Detachable drain pan that is easy to clean Molded 3-prong motor connector to save installation time and expense Motors are thermally protected and permanently lubricated Optional coated coil available ( UK) for enhanced protection in corrosive environments Sweat inlet connection to reduce leaks All models are UL recognized for the US and Canada UL classified to NSF standards Options Flare connection available as a ship loose option Section 1 Product Description U unit cooler is used wherever a small, compact unit is required, such as salad boxes, back bars and direct draw boxes. It can be mounted on the ceiling or wall. The U unit draws air in through the front and discharges it out both sides to ensure proper distribution of cool air and thus maintain a uniform box temperature. Certifications Pricing Standard Voltage U /1/ U /1/ U /1/ U /1/ U /1/ U /1/60 1,069 UK /1/ UK /1/60 1,014 UK /1/ UK /1/60 1,117 UK /1/ UK /1/60 1,210 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 9

15 Reach-In Unit Coolers Shipped-Loose Accessories Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Section 1 Part Number Room Thermostats Description Room Thermostat Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Notes Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH and under Liquid-line Solenoid Valves (LLSV) Part Number Size Medium Temperature Application (BTUH) Capacity Range (R-404A) Low Temperature Application (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 10 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

16 Step-In Unit Coolers Extended Thin Profile Overview Product Description Extended Thin Profile LTA & LTL unit coolers are the most compact designed units for reach in display cases. The unit s low height design allows the unit to hide at the top of the cooler, which gives the case a cleaner look and also allows for more room for shelves and product. These units have front access end panels for easy access to the refrigerant and electrical compartments, along with modular front access panels that make it easy to access the motors. Internally enhanced tube design produces better unit performance. Better performance, easy installation, serviceability and high quality make this unit the perfect fit for your display case needs. Standard Features Low height makes it the most compact unit for display cases where space is limited, giving the case a clean look and allowing for more shelving and product storage Textured aluminum cabinet Easy access to motors and the refrigerant and electrical components with front access panels Modular front access panels can be removed independently of the drain pan Plastic vibration isolators for fan panels and drain pan reduce noise and vibration Liquid-line solenoid wire harness comes standard for quick installation Internally enhanced tube design produces better unit performance Heaters are attached to the coil for easier serviceability Defrost termination control Fan delay control Heater safety control Section 1 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 11

17 Step-In Unit Coolers Extended Thin Profile When Do You Choose a Configurable? s & Options Pricing Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Air Defrost s with EC Motors, 115/1/60 Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT TXV TXV & LLSV White Cabinet Guard Fin Protection Copper Fin Coils LTA053AEA LTA053SA 3,132 1, ,062 Call Factory LTA079AEA LTA079SA 3,499 1, ,062 Call Factory LTA102AEA LTA102SA 4,282 1, ,062 Call Factory LTA134AEA LTA134SA 4,970 1, ,062 Call Factory LTA172AEA LTA172SA 5,615 1, ,062 Call Factory Air Defrost s with EC Motors, /1/60 LTA053BEA LTA053SA 3,132 1, ,062 Call Factory LTA079BEA LTA079SA 3,499 1, ,062 Call Factory LTA102BEA LTA102SA 4,282 1, ,062 Call Factory LTA134BEA LTA134SA 4,970 1, ,062 Call Factory LTA172BEA LTA172SA 5,615 1, ,062 Call Factory Electric Defrost s with EC Motors, /1/60 LTL046BEA LTL046SA 3,253 1, Call Factory LTL068BEA LTL068SA 3,763 1, Call Factory LTL093BEA LTL093SA 4,638 1, Call Factory LTL115BEA LTL115SA 5,360 1, Call Factory LTL133BEA LTL133SA 6,075 1, Call Factory 12 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

18 Step-In Unit Coolers Extended Thin Profile Shipped-Loose Accessories Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Room Thermostats Description Room Thermostat Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Notes Section 1 Part Number Capacity Range (BTUH) TXV ,000 BTUH and under Liquid-line Solenoid Valves (LLSV) Part Number Size Capacity Range (R-404A) Medium Temperature Application (BTUH) Low Temperature Application (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH 11,000 BTUH to 21,000 BTUH Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 13

19 Walk-In Unit Coolers Slim Contour Overview Standard Features Section 1 Product Description The Slim Contour, an innovative unit cooler with spacesaving design features offers enhanced serviceability and maximum cooling performance. These units are ideal for applications in the food service industry where maximizing storage capacity in a walk-in cooler is critical. Opting for the Beacon II Refrigeration System will further increase energy efficiency and operational cost savings. Certifications Ease of Installation & Service Modular fan cassettes for easy access to all components and service outside of cooler Fans can be removed during installation making mounting of the unit easier and safer Easily removed fan guard made from dishwasher safe polymer Coil accessible, from both the front and rear of the unit, for cleaning without removing drain pan Easy access to drain pan for cleaning Mechanical and electrical components accessible through same panel Reliable & Durable Sweat connections to reduce potential for leaks Molded fan guard design made of strong plastic material Cabinet cleans easily and looks attractive Performance Energy efficient EC (Electronically Commutated) Motors are standard Hybrid design of high grade polymer with metal back Sweat connections to reduce potential for leaks Up to 40% reduction in refrigerant charge vs. traditional evaporators Reduced Profile 30% lower unit height allows for improved storage Rear angled drain line further increases storage capacity Nomenclature UL A 041 A E A Series Type Capacity Electrical Code Motor Code Vintage Slim Contour 14 A = Air Defrost E = Electric Defrost # x 100 = BTUH A = 115/1/60 B = /1/60 E = EC Motor s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

20 Walk-In Unit Coolers Slim Contour Factory Installed Component s Include: Mounted Components s Sporlan R404A Expansion Valve Q body valve with inlet strainer Air Defrost (35 F room) will be C charged Electric Defrost (-10 F room) will be ZP charged Mechanical Room Thermostat Emerson Solenoid Valve with Dual Voltage Coil Standard Air Defrost s with EC Motors - 115/1/60 ULA041AEWMC6A 2,921 ULA050AEWMC6A 3,032 ULA072AEWMC6A 3,930 ULA100AEWMC6A 4,506 ULA132AEWMC6A 4,954 ULA153AEWMC6A 6,038 Standard Electric Defrost s with EC Motors /1/60 ULE035BEWMC6A 3,757 ULE043BEWMC6A 4,202 ULE068BEWMC6A 5,137 ULE092BEWMC6A 5,565 ULE112BEWMC6A 6,899 ULE140BEWMC6A 7,688 Section 1 Slim Contour Air Defrost s & Options When Do You Choose a Configurable? Standard Configurable Electrical Options Beacon II Assembly Air Defrost s with EC Motors - 115/1/60 Room TSTAT Factory-Installed Options Mechanical Options TXV TXV & LLSV Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz- Glow ULA041AEA ULA041SA 1,898 1, Call Factory Call Factory Call Factory Call Factory ULA050AEA ULA050SA 2,009 1, Call Factory Call Factory Call Factory Call Factory ULA072AEA ULA072SA 2,907 1, Call Factory Call Factory Call Factory Call Factory ULA100AEA ULA100SA 3,483 1, Call Factory Call Factory Call Factory Call Factory ULA132AEA ULA132SA 3,931 1, Call Factory Call Factory Call Factory Call Factory ULA153AEA ULA153SA 5,015 1, Call Factory Call Factory Call Factory Call Factory Air Defrost s with EC Motors /1/60 Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage. ULA041BEA ULA041SA 2,018 1, Call Factory Call Factory Call Factory Call Factory ULA050BEA ULA050SA 2,034 1, Call Factory Call Factory Call Factory Call Factory ULA072BEA ULA072SA 3,074 1, Call Factory Call Factory Call Factory Call Factory ULA100BEA ULA100SA 3,526 1, Call Factory Call Factory Call Factory Call Factory ULA132BEA ULA132SA 3,976 1, Call Factory Call Factory Call Factory Call Factory ULA153BEA ULA153SA 5,077 1, Call Factory Call Factory Call Factory Call Factory Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve. s Effective January 1 st s and specifications subject to change without notice. 15 Section 5

21 Walk-In Unit Coolers Slim Contour Electric Defrost s & Options Section 1 Standard When Do You Choose a Configurable? Configurable FPI Electrical Option Beacon II Assembly Electric Defrost s with EC Motors /1/60 Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage. Room TSTAT Factory-Installed Options Mechanical Option TXV TXV & LLSV Kote Electrofin Coil Coil Options Guard Fin Bronz- Glow ULE035BEA ULE035SA 7 2,734 1, Call Factory Call Factory Call Factory Call Factory ULE043BEA ULE043SA 7 3,179 1, Call Factory Call Factory Call Factory Call Factory ULE068BEA ULE068SA 7 4,114 1, Call Factory Call Factory Call Factory Call Factory ULE092BEA ULE092SA 7 4,542 1, Call Factory Call Factory Call Factory Call Factory ULE112BEA ULE112SA 7 5,876 1, Call Factory Call Factory Call Factory Call Factory ULE140BEA ULE140SA 7 6,665 1, Call Factory Call Factory Call Factory Call Factory 16 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

22 Walk-In Unit Coolers Slim Contour Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Description Notes Room Thermostats Room Thermostat Electric Room Thermostat Electronic Room Thermostat Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Section 1 Part Number Capacity Range (BTUH) TXV ,000 BTUH and under Liquid-line Solenoid Valves (LLSV) Part Number Size Capacity Range (R-404A) Medium Temperature Application (BTUH) Low Temperature Application (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH 11,000 BTUH to 21,000 BTUH Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 17

23 Walk-In Unit Coolers Low Profile Overview Section 1 Product Description The low profile unit cooler, available in air, electric, and hot gas defrost, is designed for maximum capacity while occupying a minimum amount of space inside a walk-in cooler or freezer. These units are ideal for many applications including restaurants and convenience stores. Opting for EC motors or the Beacon II Refrigeration System makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Ease of Installation & Service Cabinet design features front access panels on each side for easy access to electrical and refrigeration components All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Liquid line solenoid wire harness is factory-installed for quick installation Pre-drilled holes on the back of the unit for room thermostat Coil heater slots have been enlarged for easier installation and replacement On 4-6 fan models, drain pan has a lanyard for easy and safe access Motors plug into wiring harness for easier servicing Hot gas loop on bottom of coil for easier access is standard for hot gas defrost models Reliable & Durable Sweat connections to reduce potential for leaks Molded fan guard design made of strong plastic material Heavy gauge grained aluminum cabinet cleans easily and looks attractive Performance Internal panels are isolated for quiet operation Internally enhanced tubing and fin design for higher efficiency Reduced heater wattages Fixed defrost termination for electric, adjustable defrost termination for hot gas Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in end compartments Versatile Large diameter drain hole (3/4" ID) is located on the back of the unit Minimal height of the low profile series makes it ideal for low ceiling coolers Nomenclature 18 ADT 120 A K Series Capacity Electrical Code Vintage ADT = Air Defrost LET = Electric Defrost, 6 FPI LLE = Electric Defrost, 4 FPI HGT = Hot Gas Defrost # x 100 = BTUH A = 115/1/60 B = /1/60 C = /3/60 M = 460/1/60 AE = 115/1/60 (EC) BE = /1/60 (EC) CE = /3/60 (EC) S = Configurable s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

24 Walk-In Unit Coolers Low Profile Factory Installed Component s Include: Mounted Components s Sporlan R404A Expansion Valve Q body valve with inlet strainer Air Defrost (35 F room) will be C charged Electric Defrost (-10 F room) will be ZP charged Mechanical Room Thermostat Emerson Solenoid Valve with Dual Voltage Coil Standard Air Defrost s with EC Motors - 115/1/60 ADT040AEWMC6K 2,673 ADT052AEWMC6K 2,770 ADT065AEWMC6K 3,009 ADT070AEWMC6K 3,550 ADT090AEWMC6K 3,881 ADT104AEWMC6K 4,051 ADT120AEWMC6K 4,240 ADT130AEWMC6K 4,441 ADT140AEWMC6K 5,047 ADT156AEWMC6K 5,383 ADT180AEWMC6K 5,901 ADT208AEWMC6K 6,695 ADT260AEWMC6K 8,082 ADT312AEWMC6K 9,571 ADT370AEWMC6K 10,600 Air Defrost s with PSC Motors - 115/1/60 ADT040AWMC6K 2,328 ADT052AWMC6K 2,425 ADT065AWMC6K 2,664 ADT070AWMC6K 2,860 ADT090AWMC6K 3,191 ADT104AWMC6K 3,361 ADT120AWMC6K 3,550 ADT130AWMC6K 3,751 ADT140AWMC6K 4,012 ADT156AWMC6K 4,348 ADT180AWMC6K 4,866 ADT208AWMC6K 5,315 ADT260AWMC6K 6,357 ADT312AWMC6K 7,501 ADT370AWMC6K 8,530 Standard Electric Defrost s with EC Motors /1/60 LET035BEWMC6K 3,400 LET040BEWMC6K 3,517 LET047BEWMC6K 3,787 LET065BEWMC6K 4,600 LET075BEWMC6K 4,744 LET090BEWMC6K 4,971 LET120BEWMC6K 6,132 LET140BEWMC6K 6,818 LET160BEWMC6K 7,831 LET180BEWMC6K 8,546 LET200BEWMC6K 9,665 LET240BEWMC6K 11,314 LET280BEWMC6K 12,514 Electric Defrost s with PSC Motors /1/60 LET035BWMC6K 3,055 LET040BWMC6K 3,172 LET047BWMC6K 3,442 LET065BWMC6K 3,910 LET075BWMC6K 4,054 LET090BWMC6K 4,281 LET120BWMC6K 5,097 LET140BWMC6K 5,783 LET160BWMC6K 6,451 LET180BWMC6K 7,166 LET200BWMC6K 7,940 LET240BWMC6K 9,244 LET280BWMC6K 10,444 Section 1 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 19

25 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Beacon II Assembly Air Defrost s with EC Motors - 115/1/60 Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Quick Response Controller Split System Controller Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Kote Guard Fin Protection Bronz- Glow ADT040AEK ADT040SK 1,650 1,455 1, , ,040 Call Factory ADT052AEK ADT052SK 1,747 1,455 1, , ,040 Call Factory ADT065AEK ADT065SK 1,986 1,455 1, , ,040 Call Factory ADT070AEK ADT070SK 2,527 1,455 1, , ,062 Call Factory ADT090AEK ADT090SK 2,858 1,455 1, , ,062 Call Factory ADT104AEK ADT104SK 3,028 1,455 1, , ,062 Call Factory ADT120AEK ADT120SK 3,217 1,455 1, , ,062 Call Factory ADT130AEK ADT130SK 3,418 1,455 1, , ,062 Call Factory ADT140AEK ADT140SK 4,024 1,455 1, ,329 1,038 1,083 Call Factory ADT156AEK ADT156SK 4,360 1,455 1, ,329 1,038 1,083 Call Factory ADT180AEK ADT180SK 4,878 1,455 1, ,329 1,038 1,083 Call Factory ADT208AEK ADT208SK 5,672 1,455 1, ,329 Call Factory 1,106 Call Factory ADT260AEK ADT260SK 7,059 1,455 1, ,329 Call Factory 1,132 Call Factory ADT312AEK ADT312SK 8,128 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory ADT370AEK ADT370SK 9,157 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory Air Defrost s with EC Motors /1/60 ADT040BEK ADT040SK 1,754 1,455 1, , ,040 Call Factory ADT052BEK ADT052SK 1,769 1,455 1, , ,040 Call Factory ADT065BEK ADT065SK 2,111 1,455 1, , ,040 Call Factory ADT070BEK ADT070SK 2,672 1,455 1, , ,062 Call Factory ADT090BEK ADT090SK 2,893 1,455 1, , ,062 Call Factory ADT104BEK ADT104SK 3,065 1,455 1, , ,062 Call Factory ADT120BEK ADT120SK 3,253 1,455 1, , ,062 Call Factory ADT130BEK ADT130SK 3,456 1,455 1, , ,062 Call Factory ADT140BEK ADT140SK 4,066 1,455 1, ,329 1,038 1,083 Call Factory ADT156BEK ADT156SK 4,414 1,455 1, ,329 1,038 1,083 Call Factory ADT180BEK ADT180SK 4,930 1,455 1, ,329 1,038 1,083 Call Factory ADT208BEK ADT208SK 6,013 1,455 1, ,329 Call Factory 1,106 Call Factory ADT260BEK ADT260SK 7,485 1,455 1, ,329 Call Factory 1,132 Call Factory ADT312BEK ADT312SK 8,611 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory ADT370BEK ADT370SK 9,602 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors 20 Notes: Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Electro-fin Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

26 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Beacon II Assembly Air Defrost s with PSC Motors - 115/1/60 Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Quick Response Controller Split System Controller Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Kote Guard Fin Protection Bronz- Glow ADT040AK ADT040SK 1,305 1,455 1, , ,040 Call Factory ADT052AK ADT052SK 1,402 1,455 1, , ,040 Call Factory ADT065AK ADT065SK 1,641 1,455 1, , ,040 Call Factory ADT070AK ADT070SK 1,837 1,455 1, , ,062 Call Factory ADT090AK ADT090SK 2,168 1,455 1, , ,062 Call Factory ADT104AK ADT104SK 2,338 1,455 1, , ,062 Call Factory ADT120AK ADT120SK 2,527 1,455 1, , ,062 Call Factory ADT130AK ADT130SK 2,728 1,455 1, , ,062 Call Factory ADT140AK ADT140SK 2,989 1,455 1, ,329 1,038 1,083 Call Factory ADT156AK ADT156SK 3,325 1,455 1, ,329 1,038 1,083 Call Factory ADT180AK ADT180SK 3,843 1,455 1, ,329 1,038 1,083 Call Factory ADT208AK ADT208SK 4,292 1,455 1, ,329 Call Factory 1,106 Call Factory ADT260AK ADT260SK 5,334 1,455 1, ,329 Call Factory 1,132 Call Factory ADT312AK ADT312SK 6,058 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory ADT370AK ADT370SK 7,087 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory Air Defrost s with PSC Motors /1/60 ADT040BK ADT040SK 1,409 1,455 1, , ,040 Call Factory ADT052BK ADT052SK 1,424 1,455 1, , ,040 Call Factory ADT065BK ADT065SK 1,766 1,455 1, , ,040 Call Factory ADT070BK ADT070SK 1,982 1,455 1, , ,062 Call Factory ADT090BK ADT090SK 2,203 1,455 1, , ,062 Call Factory ADT104BK ADT104SK 2,375 1,455 1, , ,062 Call Factory ADT120BK ADT120SK 2,563 1,455 1, , ,062 Call Factory ADT130BK ADT130SK 2,766 1,455 1, , ,062 Call Factory ADT140BK ADT140SK 3,031 1,455 1, ,329 1,038 1,083 Call Factory ADT156BK ADT156SK 3,379 1,455 1, ,329 1,038 1,083 Call Factory ADT180BK ADT180SK 3,895 1,455 1, ,329 1,038 1,083 Call Factory ADT208BK ADT208SK 4,633 1,455 1, ,329 Call Factory 1,106 Call Factory ADT260BK ADT260SK 5,760 1,455 1, ,329 Call Factory 1,132 Call Factory ADT312BK ADT312SK 6,541 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory ADT370BK ADT370SK 7,532 1,455 1, ,140 1,751 Call Factory 1,154 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Notes: Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Electro-fin Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 21 Section 5

27 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Beacon II Assembly Air Defrost s with PSC Motors - 460/1/60 Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Quick Response Controller Split System Controller Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Kote Guard Fin Protection Bronz- Glow - ADT040SK 1, , ,040 Call Factory - ADT052SK 1, , ,040 Call Factory - ADT065SK 1, , ,040 Call Factory - ADT070SK 2, , ,062 Call Factory - ADT090SK 2, , ,062 Call Factory - ADT104SK 2, , ,062 Call Factory - ADT120SK 2, , ,062 Call Factory - ADT130SK 3, , ,062 Call Factory - ADT140SK 3, ,329 1,038 1,083 Call Factory - ADT156SK 3, ,329 1,038 1,083 Call Factory - ADT180SK 4, ,329 1,038 1,083 Call Factory - ADT208SK 5, ,329 Call Factory 1,106 Call Factory - ADT260SK 6, ,329 Call Factory 1,132 Call Factory - ADT312SK 7, ,140 1,751 Call Factory 1,154 Call Factory - ADT370SK 8, ,140 1,751 Call Factory 1,154 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors 22 Notes: Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Electro-fin Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

28 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Beacon II Assembly Electric Defrost s with EC Motors /1/60 Quick Response Controller Factory-Installed Options Adders Electrical Options Split System Controller Adj. Defrost Term. / Fan Delay Room TSTAT TXV Mechanical Options TXV & LLSV QCF, TXV, & LLSV LET035BEK LET035SK 6 2,377 1,455 1,455 1, ,329 LET040BEK LET040SK 6 2,494 1,455 1,455 1, ,329 LET047BEK LET047SK 6 2,764 1,455 1,455 1, ,329 LET065BEK LET065SK 6 3,577 1,455 1,455 1, ,329 LET075BEK LET075SK 6 3,721 1,455 1,455 1, ,329 LET090BEK LET090SK 6 3,948 1,455 1,455 1, ,329 LET120BEK LET120SK 6 5,109 1,455 1,455 1, ,329 LET140BEK LET140SK 6 5,795 1,455 1,455 1, ,329 LET160BEK LET160SK 6 6,808 1,455 1,455 1, ,329 LET180BEK LET180SK 6 7,523 1,455 1,455 1, ,329 LET200BEK LET200SK 6 8,642 1,455 1,455 1, ,329 LET240BEK LET240SK 6 9,871 1,455 1,455 1, ,140 1,751 LET280BEK LET280SK 6 11,071 1,455 1,455 1, ,140 1,751 LLE041BEK LLE041SK 4 2,297 1,455 1,455 1, ,329 LLE068BEK LLE068SK 4 3,869 1,455 1,455 1, ,329 LLE080BEK LLE080SK 4 4,151 1,455 1,455 1, ,329 LLE102BEK LLE102SK 4 5,065 1,455 1,455 1, ,329 LLE136BEK LLE136SK 4 6,699 1,455 1,455 1, ,329 LLE170BEK LLE170SK 4 8,464 1,455 1,455 1, ,329 LLE204BEK LLE204SK 4 9,677 1,455 1,455 1, ,140 1,751 LLE235BEK LLE235SK 4 10,883 1,455 1,455 1, ,140 1,751 Electric Defrost s with EC Motors /3/60 LET035CEK LET035SK 6 2, ,329 LET040CEK LET040SK 6 2, ,329 LET047CEK LET047SK 6 2, ,329 LET065CEK LET065SK 6 3, ,329 LET075CEK LET075SK 6 3, ,329 LET090CEK LET090SK 6 4, ,329 LET120CEK LET120SK 6 5, ,329 LET140CEK LET140SK 6 6, ,329 LET160CEK LET160SK 6 7, ,329 LET180CEK LET180SK 6 7, ,329 Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard. Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Bronz-Glow Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 23 Section 5

29 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Beacon II Assembly Quick Response Controller Factory-Installed Options Adders Electrical Options Split System Controller Adj. Defrost Term. / Fan Delay Room TSTAT TXV Mechanical Options TXV & LLSV QCF, TXV, & LLSV LET200CEK LET200SK 6 8, ,329 LET240CEK LET240SK 6 10, ,140 1,751 LET280CEK LET280SK 6 11, ,140 1,751 LLE041CEK LLE041SK 4 2, ,329 LLE068CEK LLE068SK 4 4, ,329 LLE080CEK LLE080SK 4 4, ,329 LLE102CEK LLE102SK 4 5, ,329 LLE136CEK LLE136SK 4 6, ,329 LLE170CEK LLE170SK 4 8, ,329 LLE204CEK LLE204SK 4 9, ,140 1,751 LLE235CEK LLE235SK 4 11, ,140 1,751 Electric Defrost s with PSC Motors /1/60 LET035BK LET035SK 6 2,032 1,455 1,455 1, ,329 LET040BK LET040SK 6 2,149 1,455 1,455 1, ,329 LET047BK LET047SK 6 2,419 1,455 1,455 1, ,329 LET065BK LET065SK 6 2,887 1,455 1,455 1, ,329 LET075BK LET075SK 6 3,031 1,455 1,455 1, ,329 LET090BK LET090SK 6 3,258 1,455 1,455 1, ,329 LET120BK LET120SK 6 4,074 1,455 1,455 1, ,329 LET140BK LET140SK 6 4,760 1,455 1,455 1, ,329 LET160BK LET160SK 6 5,428 1,455 1,455 1, ,329 LET180BK LET180SK 6 6,143 1,455 1,455 1, ,329 LET200BK LET200SK 6 6,917 1,455 1,455 1, ,329 LET240BK LET240SK 6 7,801 1,455 1,455 1, ,140 1,751 LET280BK LET280SK 6 9,001 1,455 1,455 1, ,140 1,751 LLE041BK LLE041SK 4 1,952 1,455 1,455 1, ,329 LLE068BK LLE068SK 4 3,179 1,455 1,455 1, ,329 LLE080BK LLE080SK 4 3,461 1,455 1,455 1, ,329 LLE102BK LLE102SK 4 4,030 1,455 1,455 1, ,329 LLE136BK LLE136SK 4 5,319 1,455 1,455 1, ,329 LLE170BK LLE170SK 4 6,739 1,455 1,455 1, ,329 LLE204BK LLE204SK 4 7,607 1,455 1,455 1, ,140 1,751 LLE235BK LLE235SK 4 8,813 1,455 1,455 1, ,140 1,751 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 24 Notes: Electric Drain Pan is standard. Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Bronz-Glow Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

30 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Beacon II Assembly Electric Defrost s with PSC Motors /3/60 Quick Response Controller Factory-Installed Options Adders Electrical Options Split System Controller Adj. Defrost Term. / Fan Delay Room TSTAT TXV Mechanical Options TXV & LLSV QCF, TXV, & LLSV LET035CK LET035SK 6 2, ,329 LET040CK LET040SK 6 2, ,329 LET047CK LET047SK 6 2, ,329 LET065CK LET065SK 6 3, ,329 LET075CK LET075SK 6 3, ,329 LET090CK LET090SK 6 3, ,329 LET120CK LET120SK 6 4, ,329 LET140CK LET140SK 6 5, ,329 LET160CK LET160SK 6 5, ,329 LET180CK LET180SK 6 6, ,329 LET200CK LET200SK 6 7, ,329 LET240CK LET240SK 6 8, ,140 1,751 LET280CK LET280SK 6 9, ,140 1,751 LLE041CK LLE041SK 4 2, ,329 LLE068CK LLE068SK 4 3, ,329 LLE080CK LLE080SK 4 3, ,329 LLE102CK LLE102SK 4 4, ,329 LLE136CK LLE136SK 4 5, ,329 LLE170CK LLE170SK 4 7, ,329 LLE204CK LLE204SK 4 7, ,140 1,751 LLE235CK LLE235SK 4 9, ,140 1,751 Electric Defrost s with PSC Motors - 460/1/60 LET035MK LET035SK 6 2, ,329 LET040MK LET040SK 6 2, ,329 LET047MK LET047SK 6 2, ,329 LET065MK LET065SK 6 3, ,329 LET075MK LET075SK 6 3, ,329 LET090MK LET090SK 6 3, ,329 LET120MK LET120SK 6 4, ,329 LET140MK LET140SK 6 5, ,329 LET160MK LET160SK 6 6, ,329 Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard. Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Bronz-Glow Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 25 Section 5

31 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Beacon II Assembly Quick Response Controller Factory-Installed Options Adders Electrical Options Split System Controller Adj. Defrost Term. / Fan Delay Room TSTAT TXV Mechanical Options TXV & LLSV QCF, TXV, & LLSV LET180MK LET180SK 6 7, ,329 LET200MK LET200SK 6 8, ,329 LET240MK LET240SK 6 9, ,140 1,751 LET280MK LET280SK 6 10, ,140 1,751 LLE041MK LLE041SK 4 2, ,329 LLE068MK LLE068SK 4 3, ,329 LLE080MK LLE080SK 4 3, ,329 LLE102MK LLE102SK 4 4, ,329 LLE136MK LLE136SK 4 6, ,329 LLE170MK LLE170SK 4 7, ,329 LLE204MK LLE204SK 4 8, ,140 1,751 LLE235MK LLE235SK 4 10, ,140 1,751 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 26 Notes: Electric Drain Pan is standard. Beacon II must be ordered as a system. Not available on 460/1/60 and 230/3/60. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, Bronz-Glow Coils and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

32 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Hot Gas Defrost s with EC Motors - 115/1/60 Electric Factory-Installed Options Adders Drain Pan Options Hot Gas Loop Insulated Mechanical Options TXV ElectroFin Coil Coil Options Bronz-Glow HGT035AEK HGT035SK 6 2,302 No Charge Standard Call Factory Call Factory HGT040AEK HGT040SK 6 2,465 No Charge Standard Call Factory Call Factory HGT047AEK HGT047SK 6 2,801 No Charge Standard Call Factory Call Factory HGT065AEK HGT065SK 6 3,453 No Charge Standard Call Factory Call Factory HGT075AEK HGT075SK 6 3,782 No Charge Standard Call Factory Call Factory HGT090AEK HGT090SK 6 4,133 No Charge Standard Call Factory Call Factory HGT120AEK HGT120SK 6 5,022 No Charge Standard Call Factory Call Factory HGT140AEK HGT140SK 6 5,844 No Charge Standard Call Factory Call Factory HGT160AEK HGT160SK 6 6,501 No Charge Standard Call Factory Call Factory HGT180AEK HGT180SK 6 7,292 No Charge Standard Call Factory Call Factory HGT200AEK HGT200SK 6 7,833 No Charge Standard Call Factory Call Factory HGT240AEK HGT240SK 6 9,283 No Charge Standard Call Factory Call Factory HGT280AEK HGT280SK 6 10,474 No Charge Standard Call Factory Call Factory HGT041AEK HGT041SK 4 2,397 No Charge Standard Call Factory Call Factory HGT068AEK HGT068SK 4 3,990 No Charge Standard Call Factory Call Factory HGT080AEK HGT080SK 4 4,222 No Charge Standard Call Factory Call Factory HGT102AEK HGT102SK 4 4,932 No Charge Standard Call Factory Call Factory HGT136AEK HGT136SK 4 6,442 No Charge Standard Call Factory Call Factory HGT170AEK HGT170SK 4 7,962 No Charge Standard Call Factory Call Factory HGT204AEK HGT204SK 4 9,322 No Charge Standard Call Factory Call Factory HGT235AEK HGT235SK 4 10,494 No Charge Standard Call Factory Call Factory Hot Gas Defrost s with EC Motors /1/60 HGT035BEK HGT035SK 6 2,355 No Charge Standard Call Factory Call Factory HGT040BEK HGT040SK 6 2,525 No Charge Standard Call Factory Call Factory HGT047BEK HGT047SK 6 2,869 No Charge Standard Call Factory Call Factory HGT065BEK HGT065SK 6 3,675 No Charge Standard Call Factory Call Factory HGT075BEK HGT075SK 6 4,003 No Charge Standard Call Factory Call Factory HGT090BEK HGT090SK 6 4,409 No Charge Standard Call Factory Call Factory HGT120BEK HGT120SK 6 5,341 No Charge Standard Call Factory Call Factory HGT140BEK HGT140SK 6 6,054 No Charge Standard Call Factory Call Factory HGT160BEK HGT160SK 6 6,913 No Charge Standard Call Factory Call Factory HGT180BEK HGT180SK 6 7,833 No Charge Standard Call Factory Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Notes: Adjustable Defrost Term. / Fan Delay is standard. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. TXV = Expansion Valve PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 27 Section 5

33 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Hot Gas Loop Insulated Mechanical Options TXV ElectroFin Coil Coil Options Bronz-Glow HGT200BEK HGT200SK 6 8,322 No Charge Standard Call Factory Call Factory HGT240BEK HGT240SK 6 9,972 No Charge Standard Call Factory Call Factory HGT280BEK HGT280SK 6 11,299 No Charge Standard Call Factory Call Factory HGT041BEK HGT041SK 4 2,456 No Charge Standard Call Factory Call Factory HGT068BEK HGT068SK 4 4,092 No Charge Standard Call Factory Call Factory HGT080BEK HGT080SK 4 4,342 No Charge Standard Call Factory Call Factory HGT102BEK HGT102SK 4 5,247 No Charge Standard Call Factory Call Factory HGT136BEK HGT136SK 4 6,843 No Charge Standard Call Factory Call Factory HGT170BEK HGT170SK 4 8,455 No Charge Standard Call Factory Call Factory HGT204BEK HGT204SK 4 9,900 No Charge Standard Call Factory Call Factory HGT235BEK HGT235SK 4 11,197 No Charge Standard Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 115/1/60 HGT035AK HGT035SK 6 1,957 No Charge Standard Call Factory Call Factory HGT040AK HGT040SK 6 2,120 No Charge Standard Call Factory Call Factory HGT047AK HGT047SK 6 2,456 No Charge Standard Call Factory Call Factory HGT065AK HGT065SK 6 2,763 No Charge Standard Call Factory Call Factory HGT075AK HGT075SK 6 3,092 No Charge Standard Call Factory Call Factory HGT090AK HGT090SK 6 3,443 No Charge Standard Call Factory Call Factory HGT120AK HGT120SK 6 3,987 No Charge Standard Call Factory Call Factory HGT140AK HGT140SK 6 4,809 No Charge Standard Call Factory Call Factory HGT160AK HGT160SK 6 5,121 No Charge Standard Call Factory Call Factory HGT180AK HGT180SK 6 5,912 No Charge Standard Call Factory Call Factory HGT200AK HGT200SK 6 6,108 No Charge Standard Call Factory Call Factory HGT240AK HGT240SK 6 7,213 No Charge Standard Call Factory Call Factory HGT280AK HGT280SK 6 8,404 No Charge Standard Call Factory Call Factory HGT041AK HGT041SK 4 2,052 No Charge Standard Call Factory Call Factory HGT068AK HGT068SK 4 3,300 No Charge Standard Call Factory Call Factory HGT080AK HGT080SK 4 3,532 No Charge Standard Call Factory Call Factory HGT102AK HGT102SK 4 3,897 No Charge Standard Call Factory Call Factory HGT136AK HGT136SK 4 5,062 No Charge Standard Call Factory Call Factory HGT170AK HGT170SK 4 6,237 No Charge Standard Call Factory Call Factory HGT204AK HGT204SK 4 7,252 No Charge Standard Call Factory Call Factory HGT235AK HGT235SK 4 8,424 No Charge Standard Call Factory Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors 28 Notes: Adjustable Defrost Term. / Fan Delay is standard. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. TXV = Expansion Valve PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

34 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electric Hot Gas Defrost s with PSC Motors /1/60 Factory-Installed Options Adders Drain Pan Options Hot Gas Loop Insulated Mechanical Options TXV ElectroFin Coil Coil Options Bronz-Glow HGT035BK HGT035SK 6 2,009 No Charge Standard Call Factory Call Factory HGT040BK HGT040SK 6 2,180 No Charge Standard Call Factory Call Factory HGT047BK HGT047SK 6 2,524 No Charge Standard Call Factory Call Factory HGT065BK HGT065SK 6 2,985 No Charge Standard Call Factory Call Factory HGT075BK HGT075SK 6 3,312 No Charge Standard Call Factory Call Factory HGT090BK HGT090SK 6 3,718 No Charge Standard Call Factory Call Factory HGT120BK HGT120SK 6 4,306 No Charge Standard Call Factory Call Factory HGT140BK HGT140SK 6 5,018 No Charge Standard Call Factory Call Factory HGT160BK HGT160SK 6 5,532 No Charge Standard Call Factory Call Factory HGT180BK HGT180SK 6 6,452 No Charge Standard Call Factory Call Factory HGT200BK HGT200SK 6 6,596 No Charge Standard Call Factory Call Factory HGT240BK HGT240SK 6 7,900 No Charge Standard Call Factory Call Factory HGT280BK HGT280SK 6 9,227 No Charge Standard Call Factory Call Factory HGT041BK HGT041SK 4 2,111 No Charge Standard Call Factory Call Factory HGT068BK HGT068SK 4 3,402 No Charge Standard Call Factory Call Factory HGT080BK HGT080SK 4 3,651 No Charge Standard Call Factory Call Factory HGT102BK HGT102SK 4 4,211 No Charge Standard Call Factory Call Factory HGT136BK HGT136SK 4 5,462 No Charge Standard Call Factory Call Factory HGT170BK HGT170SK 4 6,729 No Charge Standard Call Factory Call Factory HGT204BK HGT204SK 4 7,828 No Charge Standard Call Factory Call Factory HGT235BK HGT235SK 4 9,125 No Charge Standard Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 460/1/60 - HGT035SK 6 2,183 No Charge Standard Call Factory Call Factory - HGT040SK 6 2,351 No Charge Standard Call Factory Call Factory - HGT047SK 6 2,700 No Charge Standard Call Factory Call Factory - HGT065SK 6 3,332 No Charge Standard Call Factory Call Factory - HGT075SK 6 3,659 No Charge Standard Call Factory Call Factory - HGT090SK 6 4,067 No Charge Standard Call Factory Call Factory - HGT120SK 6 4,825 No Charge Standard Call Factory Call Factory - HGT140SK 6 5,538 No Charge Standard Call Factory Call Factory - HGT160SK 6 6,232 No Charge Standard Call Factory Call Factory - HGT180SK 6 7,148 No Charge Standard Call Factory Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors Notes: Adjustable Defrost Term. / Fan Delay is standard. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. TXV = Expansion Valve PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 29 Section 5

35 Walk-In Unit Coolers Low Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Hot Gas Loop Insulated Mechanical Options TXV ElectroFin Coil Coil Options Bronz-Glow - HGT200SK 6 7,466 No Charge Standard Call Factory Call Factory - HGT240SK 6 8,949 No Charge Standard Call Factory Call Factory - HGT280SK 6 10,276 No Charge Standard Call Factory Call Factory - HGT041SK 4 2,245 No Charge Standard Call Factory Call Factory - HGT068SK 4 3,664 No Charge Standard Call Factory Call Factory - HGT080SK 4 3,911 No Charge Standard Call Factory Call Factory - HGT102SK 4 4,604 No Charge Standard Call Factory Call Factory - HGT136SK 4 5,980 No Charge Standard Call Factory Call Factory - HGT170SK 4 7,381 No Charge Standard Call Factory Call Factory - HGT204SK 4 8,608 No Charge Standard Call Factory Call Factory - HGT235SK 4 9,904 No Charge Standard Call Factory Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors 30 Notes: Adjustable Defrost Term. / Fan Delay is standard. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. TXV = Expansion Valve PSC-TE Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

36 Walk-In Unit Coolers Low Profile Need a Hot Gas Reverse Cycle Kit? Hot Gas Reverse Cycle Kits Use the instructions below to help select the appropriate kit. Still need help? Please contact your local Sales Representative or Account Engineer for assistance. Selection Instructions: 1. Decide if kits are to be shipped-loose or factory-installed. 2. Select the correct TXV bypass kit based on unit model number and TXV style. Selections for units with the electric drain pan option are finished. For units with the standard hot gas drain pan, please proceed with instructions 3 and Select the appropriate drain pan and suction-line check valve kits based on unit model number. Drain pan and suction-line check valves and piping can be supplied by others but are necessary to complete the piping. 4. If room temperature is 0 F or below, please select an insulated drain pan as a factory-installed option. Selection for hot gas pan unit is finished. When placing an order, please specify: Unit model number Drain pan type (hot gas or electric). If ordering hot gas pan, indicate whether unit is to have insulated pan. Reverse cycle kit option codes or part numbers. If ordering factory-mounted kits, please specify TXV style, refrigerant, saturated suction temperature (SST) and liquid temperature. TXV Bypass Assembly Kits Section 1 Hot Gas s 6 FPI 4 FPI Factory-Installed Type EG Type HFESC Type SQE/SBF Option Code Option Code Option Code Adder RCBP.EG-1 RCBP.HF-1 RCBP.SQ-1 1,187 RCBP.EG-2 RCBP.HF-2 RCBP.SQ-2 1,187 RCBP.EG-3 RCBP.HF-3 RCBP.SQ-3 1,187 Shipped-Loose Type EG Type HFESC Type SQE/SBF Part Number Part Number Part Number Notes: Factory-Installed Kits include the TXV price. Customer must specify valve model, refrigerant and SST on order. Shipped-Loose Kits do NOT include the TXV price. Check Valve Kits Only available for models with the standard hot gas loop drain pan. Hot Gas s 6 FPI 4 FPI Drain Pan Loop Check Valve Kit Factory-Installed Option Code Adder Shipped-Loose Part Number DPLC.CV DPLC.CV DPLC.CV Suction Line Check Valve Kit Factory-Installed Option Code Adder Shipped-Loose Part Number SLCV.CV SLCV.CV SLCV.CV Notes: It is recommended that the customer order both check valve kits. Shipped-Loose Kits do NOT include the valve prices. The drain pan check valve kit can be ordered as an independent item, but the suction-line check valve kit must be ordered with the drain pan check valve kit in order to complete the piping Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 31

37 Walk-In Unit Coolers Low Profile Need a Hot Gas 3-Pipe Kit? Hot Gas 3-Pipe Kits Use the instructions below to help select the appropriate kit. Still need help? Please contact your local Sales Representative or Account Engineer for assistance. Section 1 Selection Instructions: 1. Decide if kits are to be shipped-loose or factory-installed. 2. Select the appropriate 3-pipe kits based on unit model number. Drain pan loop check valve and piping can be supplied by others but are necessary to complete the piping. 3. If room temperature is 0 F or below, please select an insulated drain pan as a factory-installed option. Selection for hot gas pan unit is finished. When placing an order, please specify: Unit model number Drain pan type (hot gas or electric). If ordering hot gas pan, indicate whether unit is to have insulated pan. 3-Pipe kit option codes or part numbers. If ordering factory-mounted kits, please specify TXV style, refrigerant, saturated suction temperature (SST) and liquid temperature. TXV Bypass Assembly Kits Hot Gas s 6 FPI 4 FPI Factory-Installed Type EG Type HFESC Type SQE/SBF Option Code Option Code Option Code Adder PIP.EG-1 PIP.HF-1 PIP.SQ-1 1,137 PIP.EG-2 PIP.HF-2 PIP.SQ-2 1,137 PIP.EG-3 PIP.HF-3 PIP.SQ-3 1,137 Shipped-Loose Type EG Type HFESC Type SQE/SBF Part Number Part Number Part Number Notes: Factory-Installed Kits include the TXV price. Customer must specify valve model, refrigerant and SST on order. Shipped-Loose Kits do NOT include the TXV price. Check Valve Kits Only available for models with the standard hot gas loop drain pan. Hot Gas s 6 FPI 4 FPI Drain Pan Loop Check Valve Kit Factory-Installed Option Code Adder Shipped - Loose Part Number PIPCV.CV PIPCV.CV PIPCV.CV Notes: Shipped-Loose Kits do NOT include the valve prices. 32 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

38 Walk-In Unit Coolers Low Profile Shipped-Loose Accessories Rev. 01/18 A wide range of shipped-loose accessories are available to order. Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Room Thermostats Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH and under TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH Liquid-line Solenoid Valves (LLSV) Part Number Size Description Medium Temperature Application (BTUH) Room Thermostat Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Defrost Timer (60 Hz) Capacity Range (R-404A) Low Temperature Application (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH 11,000 BTUH to 21,000 BTUH /8 24,000 BTUH to 44,000 BTUH 21,000 BTUH to 38,000 BTUH /2 36,000 BTUH to 51,000 BTUH 31,000 BTUH to 44,000 BTUH s Effective January 1 st s and specifications subject to change without notice. Notes 5505-R 30-Amp Contactor 365 Use as fan or heater contactor Check Valves 4146T 5/8" Suction Line Check Valve C 7/8" Suction Line Check Valve C 1 1/8" Suction Line Check Valve /8" Suction Line Check Valve Drain Line Heaters 5508Q 6 ft. Drain Line heater ( V, 42 Watts) P 12 ft. Drain Line heater ( V, 84 Watts) P 18 ft. Drain Line heater ( V, 126 Watts) P 36 ft. Drain Line heater ( V, 252 Watts) P 60 ft. Drain Line heater ( V, 420 Watts) Heat Exchangers Heat Exchanger used on (6FPI) and (4FPI) Electric & Hot Gas Defrost s Heat Exchanger used on (6FPI) and (4FPI) Electric & Hot Gas Defrost s Heat Exchanger used on (6FPI) and (4FPI) Electric & Hot Gas Defrost s Heat Exchanger used on (6FPI) and (4FPI) Electric & Hot Gas Defrost s Heat Exchanger used on (6FPI) and (4FPI) Electric & Hot Gas Defrost s /8" Liquid Connection OD, 5/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 3/8" Liquid Connection OD, 7/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 7/8" Suction Connecction OD, 11" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 1-1/8"" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 5/8" Liquid Connection OD, 1-3/8"" Suction Connecction OD, 14" Length, 3lbs Approx. Ship Wt. 33 Section 1 Section 5

39 Walk-In Unit Coolers Low Flow Overview Section 1 Product Description Low Flow unit coolers, available in air, electric, and hot gas defrost, are ideal for meat storage and preparation rooms, floral coolers, dough retarding and many other applications requiring low air velocities and low sound levels. With low velocity unit coolers, high humidities can be maintained to prevent product drying and weight loss. These units are ideal for any type of workroom where human comfort is important. Opting for EC motors makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Ease of Installation & Service All factory installed electrical components are wired to a terminal board in the junction box making field wiring quick and easy Access port on the suction connection allows superheat to be easily and accurately set Motors are factory-wired to unit junction box for fast installation Reliable & Durable Rust-free, all-aluminum white case with louvered intake grille for attractive appearance Sweat-type cooling coil connections reduce the potential for leaks Nickel-steel alloy heaters provide a positive defrost and have long life Hot gas models use inner drain pans with low-wattage electric heaters. This eliminates the braze joints and tubing associated with hot gas drain pan loops Performance Statically and dynamically balanced fans are designed for quiet air movement Electric defrost coils have a hermetically sealed defrost termination thermostat that does not require adjustment. Hot gas defrost units are available with an optional adjustable defrost termination thermostat (shipped-loose accessory). Cross-fin cooling coils with corrugated aluminum fins spaced 6 FPI & 3/8" OD staggered copper tubes provide optimum heat transfer and reduce the amount of refrigerant required Generous coil surface helps to maintain steady room temperature and minimize product shrinkage All models use inner drain pans to reduce sweating Thermal overload protected motors are resiliently mounted inside the unit to assure minimum noise level Versatile Inlet connection allows for external mounting of TXV Nomenclature 34 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

40 Walk-In Unit Coolers Low Flow When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders ElectroFin Coil Air Defrost s with EC Motors - 115/1/60 Coil Options Guard Fin Protection Bronz-Glow - LO070SE 5,598 Call Factory 2,150 Call Factory - LO087SE 5,861 Call Factory 2,150 Call Factory - LO118SE 6,904 Call Factory 2,150 Call Factory - LO125SE 7,327 Call Factory 2,150 Call Factory - LO150SE 7,743 Call Factory 2,150 Call Factory - LO165SE 8,541 Call Factory 2,150 Call Factory - LO189SE 9,344 Call Factory 2,602 Call Factory - LO225SE 10,108 Call Factory 2,602 Call Factory - LO266SE 10,879 Call Factory 2,602 Call Factory Air Defrost s with EC Motors /1/60 - LO070SE 5,777 Call Factory 2,150 Call Factory - LO087SE 6,035 Call Factory 2,150 Call Factory - LO118SE 7,078 Call Factory 2,150 Call Factory - LO125SE 7,504 Call Factory 2,150 Call Factory - LO150SE 7,927 Call Factory 2,150 Call Factory - LO165SE 8,719 Call Factory 2,150 Call Factory - LO189SE 9,514 Call Factory 2,602 Call Factory - LO225SE 10,284 Call Factory 2,602 Call Factory - LO266SE 11,053 Call Factory 2,602 Call Factory Air Defrost s with PSC Motors - 115/1/60 - LO070SE 4,788 Call Factory 2,150 Call Factory - LO087SE 5,051 Call Factory 2,150 Call Factory - LO118SE 6,094 Call Factory 2,150 Call Factory - LO125SE 6,517 Call Factory 2,150 Call Factory - LO150SE 6,933 Call Factory 2,150 Call Factory - LO165SE 7,731 Call Factory 2,150 Call Factory LO189AE LO189SE 8,173 Call Factory 2,602 Call Factory LO225AE LO225SE 8,937 Call Factory 2,602 Call Factory LO266AE LO266SE 9,708 Call Factory 2,602 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 35 Section 5

41 Walk-In Unit Coolers Low Flow When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders ElectroFin Coil Air Defrost s with PSC Motors /1/60 Coil Options Guard Fin Protection Bronz-Glow - LO070SE 4,967 Call Factory 2,150 Call Factory - LO087SE 5,225 Call Factory 2,150 Call Factory - LO118SE 6,268 Call Factory 2,150 Call Factory - LO125SE 6,694 Call Factory 2,150 Call Factory - LO150SE 7,117 Call Factory 2,150 Call Factory - LO165SE 7,909 Call Factory 2,150 Call Factory LO189BE LO189SE 8,344 Call Factory 2,602 Call Factory LO225BE LO225SE 9,112 Call Factory 2,602 Call Factory LO266BE LO266SE 9,882 Call Factory 2,602 Call Factory Air Defrost s with Shaded Pole Motors - 115/1/60 LO070AE LO070SE 4,426 Call Factory 2,150 Call Factory LO087AE LO087SE 4,689 Call Factory 2,150 Call Factory LO118AE LO118SE 5,732 Call Factory 2,150 Call Factory LO125AE LO125SE 6,155 Call Factory 2,150 Call Factory LO150AE LO150SE 6,571 Call Factory 2,150 Call Factory LO165AE LO165SE 7,369 Call Factory 2,150 Call Factory Air Defrost s with Shaded Pole Motors /1/60 LO070BE LO070SE 4,605 Call Factory 2,150 Call Factory LO087BE LO087SE 4,863 Call Factory 2,150 Call Factory LO118BE LO118SE 5,906 Call Factory 2,150 Call Factory LO125BE LO125SE 6,332 Call Factory 2,150 Call Factory LO150BE LO150SE 6,755 Call Factory 2,150 Call Factory LO165BE LO165SE 7,547 Call Factory 2,150 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 36 Notes: Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

42 Walk-In Unit Coolers Low Flow When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Fixed Defrost Term. Thermostat Electric Defrost s with EC Motors /1/60 Coil Options Bronz-Glow - LOD070SE 6,107 Standard Call Factory - LOD087SE 6,778 Standard Call Factory - LOD118SE 8,351 Standard Call Factory - LOD125SE 8,575 Standard Call Factory - LOD150SE 8,768 Standard Call Factory - LOD165SE 10,125 Standard Call Factory - LOD189SE 10,591 Standard Call Factory - LOD225SE 11,763 Standard Call Factory - LOD266SE 12,375 Standard Call Factory Electric Defrost s with PSC Motors /1/60 - LOD070SE 5,297 Standard Call Factory - LOD087SE 5,968 Standard Call Factory - LOD118SE 7,541 Standard Call Factory - LOD125SE 7,765 Standard Call Factory - LOD150SE 7,958 Standard Call Factory - LOD165SE 9,315 Standard Call Factory LOD189BE LOD189SE 9,419 Standard Call Factory LOD225BE LOD225SE 10,593 Standard Call Factory LOD266BE LOD266SE 11,203 Standard Call Factory Electric Defrost s with Shaded Pole Motors /1/60 LOD070BE LOD070SE 4,935 Standard Call Factory LOD087BE LOD087SE 5,606 Standard Call Factory LOD118BE LOD118SE 7,179 Standard Call Factory LOD125BE LOD125SE 7,403 Standard Call Factory LOD150BE LOD150SE 7,596 Standard Call Factory LOD165BE LOD165SE 8,953 Standard Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard on electric defrost models. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 37 Section 5

43 Walk-In Unit Coolers Low Flow When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Hot Gas Defrost s with EC Motors - 115/1/60 Factory-Installed Options Adders Coil Options Bronz-Glow - LOG070SE 6,005 Call Factory - LOG087SE 6,673 Call Factory - LOG118SE 8,244 Call Factory - LOG125SE 8,467 Call Factory - LOG150SE 8,667 Call Factory - LOG165SE 10,014 Call Factory - LOG189SE 10,484 Call Factory - LOG225SE 11,656 Call Factory - LOG266SE 12,268 Call Factory Hot Gas Defrost s with EC Motors /1/60 - LOG070SE 6,182 Call Factory - LOG087SE 6,847 Call Factory - LOG118SE 8,419 Call Factory - LOG125SE 8,641 Call Factory - LOG150SE 8,841 Call Factory - LOG165SE 10,197 Call Factory - LOG189SE 10,660 Call Factory - LOG225SE 11,835 Call Factory - LOG266SE 12,447 Call Factory Hot Gas Defrost s with PSC Motors - 115/1/60 - LOG070SE 5,195 Call Factory - LOG087SE 5,863 Call Factory - LOG118SE 7,434 Call Factory - LOG125SE 7,657 Call Factory - LOG150SE 7,857 Call Factory - LOG165SE 9,204 Call Factory LOG189AE LOG189SE 9,312 Call Factory LOG225AE LOG225SE 10,486 Call Factory LOG266AE LOG266SE 11,096 Call Factory Need a Reverse Cycle Kit? Look on page 40 for the available kits in the Shipped-Loose Accessories. Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 38 Notes: Electric Drain Pan is standard on hot gas defrost models. Hot gas loop not available. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

44 Walk-In Unit Coolers Low Flow When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Coil Options Bronz-Glow Hot Gas Defrost s with PSC Motors /1/60 - LOG070SE 5,372 Call Factory - LOG087SE 6,037 Call Factory - LOG118SE 7,609 Call Factory - LOG125SE 7,831 Call Factory - LOG150SE 8,031 Call Factory - LOG165SE 9,387 Call Factory LOG189BE LOG189SE 9,489 Call Factory LOG225BE LOG225SE 10,664 Call Factory LOG266BE LOG266SE 11,275 Call Factory Hot Gas Defrost s with Shaded Pole Motors - 115/1/60 LOG070AE LOG070SE 4,833 Call Factory LOG087AE LOG087SE 5,501 Call Factory LOG118AE LOG118SE 7,072 Call Factory LOG125AE LOG125SE 7,295 Call Factory LOG150AE LOG150SE 7,495 Call Factory LOG165AE LOG165SE 8,842 Call Factory Hot Gas Defrost s with Shaded Pole Motors /1/60 LOG070BE LOG070SE 5,010 Call Factory LOG087BE LOG087SE 5,675 Call Factory LOG118BE LOG118SE 7,247 Call Factory LOG125BE LOG125SE 7,469 Call Factory LOG150BE LOG150SE 7,669 Call Factory LOG165BE LOG165SE 9,025 Call Factory Need a Reverse Cycle Kit? Look on page 40 for the available kits in the Shipped-Loose Accessories. Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard on hot gas defrost models. Hot gas loop not available. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 39 Section 5

45 Walk-In Unit Coolers Low Flow Shipped-Loose Accessories Section 1 Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Room Thermostats 40 Description Room Thermostat Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Check Valves 5890C 7/8" Suction Line Check Valve Drain Line Heaters 5508Q 6 ft. Drain Line Heater ( V, 42 Watts) P 12 ft. Drain Line Heater ( V, 84 Watts) P 18 ft. Drain Line Heater ( V, 126 Watts) P 36 ft. Drain Line Heater ( V, 252 Watts) P 60 ft. Drain Line Heater ( V, 420 Watts) Air Filters Air Filters 381 Use on s LO/LOD/LOG Air Filters 319 Use on s LO/LOD/LOG Air Filters 319 Use on s LO/LOD/LOG 266 Heat Exchangers Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on 266 Electric & Hot Gas Defrost s 520 Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH and under TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH Liquid-line Solenoid Valves (LLSV) Part Number Size Capacity Range (R-404A) Medium Temperature Application (BTUH) /8 12,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH /8 24,000 BTUH to 44,000 BTUH /2 36,000 BTUH to 51,000 BTUH 5766Y 349 1/2 51,000 BTUH to 72,000 BTUH Notes 3/8" Liquid Connection OD, 7/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 7/8" Suction Connecction OD, 11" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 7/8" Suction Connecction OD, 11" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 1-1/8"" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 5/8" Liquid Connection OD, 1-3/8"" Suction Connecction OD, 14" Length, 3lbs Approx. Ship Wt. Hot Gas Reverse Cycle Kits (Hot Gas s Only) Electric pan is standard on all hot gas models. Hot gas loop not available. Kits includes one check valve and piping for liquid bypass around expansion valve and instructions for field installation. s Used On TXV Bypass Kits Part Number LOG070 - LOG LOG s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

46 Walk-In Unit Coolers Low Velocity Center Mount Overview Product Description The low velocity center mount units, available in air, electric, and hot gas defrost, are ideal for floral storage, fresh fruit and vegetables, dough retarding, fresh meat storage and preparations, and many other applications. The low air flow and quiet fans are classically suited for work room applications. The generous coil surface combined with close T.D. system balance provides high humidity characteristics to minimize product shrinkage and drying. Opting for EC motors or the Beacon II Refrigeration System makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Ease of Installation & Service Liquid line solenoid wire harness is factory-installed for quick installation All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Cabinet design features access panels on each end for easy access to electrical and refrigeration components Fan panel is lightweight and can easily be lowered for easy servicing and installation Expansion valve mounts inside the cabinet Reliable & Durable Heavy gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with PVC coating for durability Sweat connections to reduce potential for leaks Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Motor rail is design for maximum strength and durability Performance Internally enhanced tubing and fin design for higher efficiency Electric defrost models incorporate high quality tubular heaters and a standard fixed defrost termination thermostat Hot gas defrost models come with a shipped-loose adjustable fan delay and defrost termination thermostat Motors are life lubricated and thermal overload protected Versatile Low height makes it ideal for low ceiling coolers - larger models are only 15 inches tall, allowing for maximum headroom and more product storage Unit designed to be mounted flush against the ceiling or suspended on rods Section 1 Nomenclature WK 100 A C Series Capacity Electrical Code Vintage WK = Low Velocity Center Mount, air defrost WKE = Low Velocity Center Mount, electric defrost WKG= Low Velocity Center Mount, hot gas defrost # x 100 = BTUH A= 115/1/60 B = /1/60 AE = 115/1/60 (EC) BE = /1/60 (EC) S = Configurable Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 41

47 Walk-In Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Air Defrost s with EC Motors - 115/1/60 Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV ElectroFin Coil Guard Fin Protection Bronz-Glow WK050AEC WK050SC 3,655 1, ,457 Call Factory 1,040 Call Factory WK075AEC WK075SC 4,234 1, ,457 Call Factory 1,040 Call Factory WK100AEC WK100SC 5,190 1, ,457 Call Factory 1,533 Call Factory WK130AEC WK130SC 6,049 1, ,457 Call Factory 1,533 Call Factory WK155AEC WK155SC 6,759 1, ,457 Call Factory 1,533 Call Factory WK180AEC WK180SC 8,281 1, ,457 Call Factory 2,090 Call Factory WK210AEC WK210SC 9,384 1, Call Factory 2,435 Call Factory WK270AEC WK270SC 10,277 1, Call Factory 2,435 Call Factory WK340AEC WK340SC 13,181 1, ,291 - Call Factory 3,304 Call Factory Air Defrost s with EC Motors /1/60 WK050BEC WK050SC 3,850 1, ,457 Call Factory 1,040 Call Factory WK075BEC WK075SC 4,464 1, ,457 Call Factory 1,040 Call Factory WK100BEC WK100SC 5,455 1, ,457 Call Factory 1,533 Call Factory WK130BEC WK130SC 6,371 1, ,457 Call Factory 1,533 Call Factory WK155BEC WK155SC 7,120 1, ,457 Call Factory 1,533 Call Factory WK180BEC WK180SC 8,711 1, ,457 Call Factory 2,090 Call Factory WK210BEC WK210SC 9,862 1, Call Factory 2,435 Call Factory WK270BEC WK270SC 10,804 1, Call Factory 2,435 Call Factory WK340BEC WK340SC 13,859 1, ,291 - Call Factory 3,304 Call Factory Air Defrost s with PSC Motors - 115/1/60 WK050AC WK050SC 3,288 1, ,457 Call Factory 1,040 Call Factory WK075AC WK075SC 3,867 1, ,457 Call Factory 1,040 Call Factory WK130AC WK130SC 5,315 1, ,457 Call Factory 1,533 Call Factory WK100AC WK100SC 4,456 1, ,457 Call Factory 1,533 Call Factory WK155AC WK155SC 6,025 1, ,457 Call Factory 1,533 Call Factory WK180AC WK180SC 7,180 1, ,457 Call Factory 2,090 Call Factory WK210AC WK210SC 7,916 1, Call Factory 2,435 Call Factory WK270AC WK270SC 8,809 1, Call Factory 2,435 Call Factory WK340AC WK340SC 11,345 1, ,291 - Call Factory 3,304 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 42 Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

48 Walk-In Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Air Defrost s with PSC Motors /1/60 Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV ElectroFin Coil Guard Fin Protection Bronz-Glow WK050BC WK050SC 3,483 1, ,457 Call Factory 1,040 Call Factory WK075BC WK075SC 4,097 1, ,457 Call Factory 1,040 Call Factory WK100BC WK100SC 4,721 1, ,457 Call Factory 1,533 Call Factory WK130BC WK130SC 5,637 1, ,457 Call Factory 1,533 Call Factory WK155BC WK155SC 6,386 1, ,457 Call Factory 1,533 Call Factory WK180BC WK180SC 7,610 1, ,457 Call Factory 2,090 Call Factory WK210BC WK210SC 8,394 1, Call Factory 2,435 Call Factory WK270BC WK270SC 9,336 1, Call Factory 2,435 Call Factory WK340BC WK340SC 12,023 1, ,291 - Call Factory 3,304 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 43 Section 5

49 Walk-In Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Beacon II Assembly Electric Defrost s with EC Motors /1/60 Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Adj. Defrost Term. / Fan Delay Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Bronz-Glow WKE050BEC WKE050SC 4,274 1, ,457 Call Factory WKE075BEC WKE075SC 4,961 1, ,457 Call Factory WKE100BEC WKE100SC 6,037 1, ,457 Call Factory WKE130BEC WKE130SC 7,058 1, ,457 Call Factory WKE155BEC WKE155SC 7,904 1, ,457 Call Factory WKE180BEC WKE180SC 9,641 1, ,457 Call Factory WKE210BEC WKE210SC 10,888 1, Call Factory WKE270BEC WKE270SC 11,947 1, Call Factory WKE340BEC WKE340SC 15,336 1, ,291 - Call Factory Electric Defrost s with PSC Motors /1/60 WKE050BC WKE050SC 3,907 1, ,457 Call Factory WKE075BC WKE075SC 4,594 1, ,457 Call Factory WKE100BC WKE100SC 5,303 1, ,457 Call Factory WKE130BC WKE130SC 6,324 1, ,457 Call Factory WKE155BC WKE155SC 7,170 1, ,457 Call Factory WKE180BC WKE180SC 8,540 1, ,457 Call Factory WKE210BC WKE210SC 9,420 1, Call Factory WKE270BC WKE270SC 10,479 1, Call Factory WKE340BC WKE340SC 13,500 1, ,291 - Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 44 Notes: Electric Drain Pan is standard. Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

50 Walk-In Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Mechanical Options TXV Hot Gas Defrost s with EC Motors - 115/1/60 TXV & LLSV ElectroFin Coil Coil Options Bronz-Glow - WKG100SC 5, Call Factory Call Factory - WKG130SC 6, Call Factory Call Factory - WKG155SC 7, Call Factory Call Factory - WKG180SC 9, Call Factory Call Factory - WKG210SC 10, Call Factory Call Factory - WKG270SC 11, Call Factory Call Factory - WKG340SC 14, ,291 Call Factory Call Factory Hot Gas Defrost s with EC Motors /1/60 - WKG100SC 5, Call Factory Call Factory - WKG130SC 7, Call Factory Call Factory - WKG155SC 8, Call Factory Call Factory - WKG180SC 9, Call Factory Call Factory - WKG210SC 11, Call Factory Call Factory - WKG270SC 12, Call Factory Call Factory - WKG340SC 15, ,291 Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 115/1/60 WKG100AC WKG100SC 4, Call Factory Call Factory WKG130AC WKG130SC 6, Call Factory Call Factory WKG155AC WKG155SC 6, Call Factory Call Factory WKG180AC WKG180SC 8, Call Factory Call Factory WKG210AC WKG210SC 9, Call Factory Call Factory WKG270AC WKG270SC 10, Call Factory Call Factory WKG340AC WKG340SC 13, ,291 Call Factory Call Factory Hot Gas Defrost s with PSC Motors /1/60 WKG100BC WKG100SC 5, Call Factory Call Factory WKG130BC WKG130SC 6, Call Factory Call Factory WKG155BC WKG155SC 7, Call Factory Call Factory WKG180BC WKG180SC 8, Call Factory Call Factory WKG210BC WKG210SC 9, Call Factory Call Factory WKG270BC WKG270SC 10, Call Factory Call Factory WKG340BC WKG340SC 13, ,291 Call Factory Call Factory Need a Reverse Cycle Kit? Look on page 46 for the available kits in the Shipped-Loose Accessories. Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard. Hot gas loop not available. Adjustable Defrost Term. / Fan Delay is standard. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 45 Section 5

51 Walk-In Unit Coolers Low Velocity Center Mount Shipped-Loose Accessories Section 1 Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Room Thermostats 46 Description Room Thermostat Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Electric Defrost Timer (60 Hz) Notes 5505-R 30-Amp Contactor 365 Use as fan or heater contactor Check Valves 5890C 7/8" Suction Line Check Valve C 1 1/8" Suction Line Check Valve /8" Suction Line Check Valve Drain Line Heaters 5508Q 6 ft. Drain Line heater ( V, 42 Watts) P 12 ft. Drain Line heater ( V, 84 Watts) P 18 ft. Drain Line heater ( V, 126 Watts) P 36 ft. Drain Line heater ( V, 252 Watts) P 60 ft. Drain Line heater ( V, 420 Watts) Heat Exchangers Heat Exchanger used on 050 Electric Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on Electric & Hot Gas Defrost s Heat Exchanger used on 340 Electric & Hot Gas Defrost s 520 Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH and under TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH TXV ,000 BTUH to 120,000 BTUH Liquid-line Solenoid Valves (LLSV) Part Number Size Capacity Range (R-404A) Medium Temperature Application (BTUH) /8 12,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH /8 24,000 BTUH to 44,000 BTUH /2 36,000 BTUH to 51,000 BTUH 5766Y 349 1/2 51,000 BTUH to 72,000 BTUH 3/8" Liquid Connection OD, 5/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 3/8" Liquid Connection OD, 7/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 7/8" Suction Connecction OD, 11" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 1-1/8"" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 5/8" Liquid Connection OD, 1-3/8"" Suction Connecction OD, 14" Length, 3lbs Approx. Ship Wt. Hot Gas Reverse Cycle Kits (Hot Gas s Only) Electric pan is standard on all hot gas models. Hot gas loop not available. Kits includes one check valve and piping for liquid bypass around expansion valve and instructions for field installation. s Used On Type SQE, SBF, or HFESC Part Number TXV Bypass Kits Type S Part Number WKG WKG130 - WKG WKG s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

52 Walk-In Unit Coolers Center Mount Overview Product Description Center mount unit coolers, available in air or electric defrost, are ideal for tight storage situations because they are ceiling mount and have a height of only 8-5/8" allowing for maximum headroom in a cooler or freezer. The center mount design allows for product to be stacked all around while air flow distributes evenly throughout the box. Opting for EC motors or the Beacon II Refrigeration System makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Certifications Standard Features Ease of Installation & Service Panels on ends quickly remove for complete access to refrigerant components and electrical terminal block during installation and servicing Tapered mounting provides proper slope for condensate drainage to one end of the unit Reliable & Durable Heavy-gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with PVC coating for durability Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Performance Quick disconnect, waterproof plug and receptacle for each motor in all models High-efficiency aluminum fins with full collars cover mechanically expanded copper tubes Highest quality tubular heaters provide fast and economical defrost Generous coil surface gives proper compressor balance Standard adjustable defrost termination fan delay thermostat Motors are life lubricated and thermal overload protected Air moves across the ceiling in both directions providing even air distribution throughout the cooler Versatile Compact, ceiling mount and center mount design allows for shelving and storage of product around all walls Section 1 Nomenclature Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 47

53 Walk-In Unit Coolers Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Air Defrost s with EC Motors - 115/1/60 Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Kote ElectroFin Coil Guard Fin Protection Bronz-Glow SM052AEE SM052SE 2,462 1, , Call Factory 608 Call Factory SM076AEE SM076SE 3,288 1, , Call Factory 834 Call Factory SM090AEE SM090SE 3,616 1, , Call Factory 834 Call Factory SM102AEE SM102SE 3,925 1, , Call Factory 834 Call Factory SM108AEE SM108SE 4,423 1, ,457 Call Factory Call Factory 1,184 Call Factory SM134AEE SM134SE 4,941 1, ,457 Call Factory Call Factory 1,184 Call Factory SM156AEE SM156SE 5,422 1, ,457 Call Factory Call Factory 1,184 Call Factory SM179AEE SM179SE 6,237 1, ,457 Call Factory Call Factory 1,473 Call Factory SM208AEE SM208SE 6,822 1, ,457 Call Factory Call Factory 1,473 Call Factory SM249AEE SM249SE 8,350 1, ,457 Call Factory Call Factory 1,897 Call Factory Air Defrost s with EC Motors /1/60 SM052BEE SM052SE 2,628 1, , Call Factory 608 Call Factory SM076BEE SM076SE 3,488 1, , Call Factory 834 Call Factory SM090BEE SM090SE 3,814 1, , Call Factory 834 Call Factory SM102BEE SM102SE 4,128 1, , Call Factory 834 Call Factory SM108BEE SM108SE 4,668 1, ,457 Call Factory Call Factory 1,184 Call Factory SM134BEE SM134SE 5,176 1, ,457 Call Factory Call Factory 1,184 Call Factory SM156BEE SM156SE 5,658 1, ,457 Call Factory Call Factory 1,184 Call Factory SM179BEE SM179SE 6,511 1, ,457 Call Factory Call Factory 1,473 Call Factory SM208BEE SM208SE 7,104 1, ,457 Call Factory Call Factory 1,473 Call Factory SM249BEE SM249SE 8,659 1, ,457 Call Factory Call Factory 1,897 Call Factory Air Defrost s with PSC Motors - 115/1/60 SM052AE SM052SE 2,095 1, , Call Factory 608 Call Factory SM076AE SM076SE 2,554 1, , Call Factory 834 Call Factory SM090AE SM090SE 2,882 1, , Call Factory 834 Call Factory SM102AE SM102SE 3,191 1, , Call Factory 834 Call Factory SM108AE SM108SE 3,322 1, ,457 Call Factory Call Factory 1,184 Call Factory SM134AE SM134SE 3,840 1, ,457 Call Factory Call Factory 1,184 Call Factory SM156AE SM156SE 4,321 1, ,457 Call Factory Call Factory 1,184 Call Factory SM179AE SM179SE 4,769 1, ,457 Call Factory Call Factory 1,473 Call Factory SM208AE SM208SE 5,354 1, ,457 Call Factory Call Factory 1,473 Call Factory SM249AE SM249SE 6,515 1, ,457 Call Factory Call Factory 1,897 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 48 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

54 Walk-In Unit Coolers Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Air Defrost s with PSC Motors /1/60 TXV TXV & LLSV QCF, TXV, & LLSV Kote ElectroFin Coil Guard Fin Protection Bronz-Glow SM052BE SM052SE 2,261 1, , Call Factory 608 Call Factory SM076BE SM076SE 2,754 1, , Call Factory 834 Call Factory SM090BE SM090SE 3,080 1, , Call Factory 834 Call Factory SM102BE SM102SE 3,394 1, , Call Factory 834 Call Factory SM108BE SM108SE 3,567 1, ,457 Call Factory Call Factory 1,184 Call Factory SM134BE SM134SE 4,075 1, ,457 Call Factory Call Factory 1,184 Call Factory SM156BE SM156SE 4,557 1, ,457 Call Factory Call Factory 1,184 Call Factory SM179BE SM179SE 5,043 1, ,457 Call Factory Call Factory 1,473 Call Factory SM208BE SM208SE 5,636 1, ,457 Call Factory Call Factory 1,473 Call Factory SM249BE SM249SE 6,824 1, ,457 Call Factory Call Factory 1,897 Call Factory Section 1 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 49

55 Walk-In Unit Coolers Center Mount When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Electric Defrost s with EC Motors /1/60 Room TSTAT TXV TXV & LLSV QCF, TXV, & LLSV Bronz-Glow SME040BEE SME040SE 3,232 1, ,457 Call Factory SME054BEE SME054SE 4,357 1, ,457 Call Factory SME065BEE SME065SE 4,510 1, ,457 Call Factory SME090BEE SME090SE 5,672 1, ,457 Call Factory SME130BEE SME130SE 6,207 1, ,457 Call Factory SME174BEE SME174SE 8,047 1, ,457 Call Factory Electric Defrost s with PSC Motors /1/60 SME040BE SME040SE 2,865 1, ,457 Call Factory SME054BE SME054SE 3,623 1, ,457 Call Factory SME065BE SME065SE 3,776 1, ,457 Call Factory SME090BE SME090SE 4,571 1, ,457 Call Factory SME130BE SME130SE 5,106 1, ,457 Call Factory SME174BE SME174SE 6,579 1, ,457 Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. 50 Notes: Electric Drain Pan and Adjustable Defrost Term. / Fan Delay are standard. Beacon II must be ordered as a system. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve; QCF = Quick Connect Fittings. 460V Fan Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

56 Walk-In Unit Coolers Center Mount Shipped-Loose Accessories Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Part Number Room Thermostats Description Room Thermostats Electronic Room Thermostat Defrost Controls 4267W Adjustable Defrost Control / Fan Delay Switch Check Valves 5890C 7/8" Suction Line Check Valve C 1 1/8" Suction Line Check Valve Drain Line Heaters 5508Q 6 ft. Drain Line heater ( V, 42 Watts) P 12 ft. Drain Line heater ( V, 84 Watts) P 18 ft. Drain Line heater ( V, 126 Watts) P 36 ft. Drain Line heater ( V, 252 Watts) P 60 ft. Drain Line heater ( V, 420 Watts) Heat Exchangers Heat Exchanger used on 040 Electric Defrost s Heat Exchanger used on Electric Defrost s Heat Exchanger used on Electric Defrost s 310 Notes 3/8" Liquid Connection OD, 5/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 3/8" Liquid Connection OD, 7/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. 1/2" Liquid Connection OD, 1-1/8" Suction Connecction OD, 14" Length, 2lbs Approx. Ship Wt. Section 1 Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH and under TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH Liquid-line Solenoid Valves (LLSV) Part Number Size Medium Temperature Application (BTUH) Capacity Range (R-404A) Low Temperature Application (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH 11,000 BTUH to 21,000 BTUH /8 24,000 BTUH to 44,000 BTUH 21,000 BTUH to 38,000 BTUH Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 51

57 Walk-In Unit Coolers Medium Profile Overview Section 1 Product Description Medium profile unit coolers, available in air, electric, and hot gas defrost, are ideal for numerous commercial and industrial applications. With a modular design that is only 25 inches high, these units provide superior quality and a long, dependable life for many different applications. Opting for EC motors or the Beacon II Refrigeration System makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Standard Features Ease of Installation & Service All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Schrader valve provided for suction pressure measurement Liquid line solenoid wire harness is factory-installed for quick installation Coil heater slots have been enlarged for easier installation and replacement Heaters are coil face mounted for easy access Front hinged drain pan for easy access Motors plug into wiring harness for easier servicing Reliable & Durable Heavy gauge textured aluminum cabinet Sweat connections to reduce potential for leaks Patented Thermo-Flex coil design allows the coil to flex during periods of defrost resulting in expansion of the coil surface comes with a 5-year warranty Heavy plastic molded fan guards for extended air throw Reliable nickel steel alloy defrost heater elements Thermally protected, lifetime-lubricated single phase PSC motors Performance External equalizer connection Internal panels are isolated for quiet operation Electric defrost models have fixed defrost termination / fan delay and heater limit thermostats PSC motors Versatile Large diameter drain fitting (3/4 ID) Beacon II compatible Different motor and voltage options available Certifications Nomenclature 52 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

58 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Electrical Options Beacon II Assembly Room TSTAT Air Defrost s with VSEC or 2 Speed EC motors - 115/1/60 Factory-Installed Options Adders Mechanical Options TXV TXV & LLSV Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMA130SA 4,631 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 5,316 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 8,043 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 9,777 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 12,511 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 14,465 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 17,274 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 18,125 2, ,238 Call Factory Call Factory 1,333 Call Factory Air Defrost s with VSEC or 2 Speed EC motors 230/1/60 - BMA130SA 4,699 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 5,378 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 8,171 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 9,906 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 12,710 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 14,665 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 17,533 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 18,388 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA710SA 21,274 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Air Defrost s with EC Motors - 115/1/60 - BMA130SA 4,387 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 5,073 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 7,555 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 9,289 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 11,779 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 13,733 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 16,299 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 17,149 2, ,238 Call Factory Call Factory 1,333 Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and ring fan guards optional at no additional cost. Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 53 Section 5

59 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Electrical Options Beacon II Assembly Air Defrost s with EC Motors /1/60 Room TSTAT Factory-Installed Options Adders Mechanical Options TXV TXV & LLSV Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMA130SA 4,455 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 5,134 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 7,683 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 9,418 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 11,978 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 13,933 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 16,558 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 17,412 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA710SA 20,054 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Air Defrost s with PSC Motors - 115/1/60 BMA130AA BMA130SA 3,722 2, ,270 Call Factory 1,148 Call Factory BMA155AA BMA155SA 4,408 2, ,270 Call Factory 1,148 Call Factory BMA245AA BMA245SA 6,225 2, Call Factory Call Factory 1,211 Call Factory BMA300AA BMA300SA 7,959 2, Call Factory Call Factory 1,211 Call Factory BMA365AA BMA365SA 9,784 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA450AA BMA450SA 11,738 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA510AA BMA510SA 13,639 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA600AA BMA600SA 14,489 2, ,238 Call Factory Call Factory 1,333 Call Factory Air Defrost s with PSC Motors /1/60 BMA130BA BMA130SA 3,790 2, ,270 Call Factory 1,148 Call Factory BMA155BA BMA155SA 4,469 2, ,270 Call Factory 1,148 Call Factory BMA245BAF BMA245SA 6,353 2, Call Factory Call Factory 1,211 Call Factory BMA300BA BMA300SA 8,088 2, Call Factory Call Factory 1,211 Call Factory BMA365BA BMA365SA 9,983 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA450BA BMA450SA 11,938 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA510BA BMA510SA 13,898 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA600BA BMA600SA 14,752 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA710BA BMA710SA 16,729 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 54 Notes: Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and ring fan guards optional at no additional cost. Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

60 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Electrical Options Beacon II Assembly Air Defrost s with PSC Motors - 460/1/60 Room TSTAT Factory-Installed Options Adders Mechanical Options TXV TXV & LLSV Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow BMA130MA BMA130SA 3,983 2, ,270 Call Factory 1,148 Call Factory BMA155MA BMA155SA 4,664 2, ,270 Call Factory 1,148 Call Factory BMA245MA BMA245SA 6,741 2, Call Factory Call Factory 1,211 Call Factory BMA300MA BMA300SA 8,474 2, Call Factory Call Factory - Call Factory BMA365MA BMA365SA 10,557 2, ,238 Call Factory Call Factory - Call Factory BMA450MA BMA450SA 12,514 2, ,238 Call Factory Call Factory - Call Factory BMA510MA BMA510SA 14,666 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA600MA BMA600SA 15,521 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA710MA BMA710SA 17,690 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Air Defrost s with PSC Motors - 575/1/60 BMA130LA BMA130SA 4,061 2, ,270 Call Factory 1,148 Call Factory BMA155LA BMA155SA 4,757 2, ,270 Call Factory 1,148 Call Factory BMA245LA BMA245SA 6,876 2, Call Factory Call Factory 1,211 Call Factory BMA300LA BMA300SA 8,646 2, Call Factory Call Factory 1,211 Call Factory BMA365LA BMA365SA 10,766 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA450LA BMA450SA 12,766 2, ,238 Call Factory Call Factory 1,276 Call Factory BMA510LA BMA510SA 14,961 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA600LA BMA600SA 15,830 2, ,238 Call Factory Call Factory 1,333 Call Factory BMA710LA BMA710SA 18,043 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Air Defrost s with Totally-Enclosed PSC Motors /1/60 - BMA130SA 4,044 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 4,723 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 6,861 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 8,596 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 10,745 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 12,700 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 14,914 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 15,768 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA710SA 17,999 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and ring fan guards optional at no additional cost. Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 55 Section 5

61 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Electrical Options Beacon II Assembly Room TSTAT Factory-Installed Options Adders Mechanical Options TXV Air Defrost s with Totally-Enclosed PSC Motors - 460/1/60 TXV & LLSV Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMA130SA 4,237 2, ,270 Call Factory 1,148 Call Factory - BMA155SA 4,918 2, ,270 Call Factory 1,148 Call Factory - BMA245SA 7,249 2, Call Factory Call Factory 1,211 Call Factory - BMA300SA 8,982 2, Call Factory Call Factory 1,211 Call Factory - BMA365SA 11,319 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA450SA 13,276 2, ,238 Call Factory Call Factory 1,276 Call Factory - BMA510SA 15,682 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA600SA 16,537 2, ,238 Call Factory Call Factory 1,333 Call Factory - BMA710SA 18,960 2, ,117 1,715 Call Factory Call Factory 1,368 Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 56 Notes: Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and ring fan guards optional at no additional cost. Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

62 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Electric Defrost s with VSEC or 2 Speed EC motors 230/1/60 Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow - BME101SA 6 5,435 2, Standard Call Factory Call Factory - BME140SA 6 6,269 2, Standard Call Factory Call Factory - BME190SA 6 9,030 2, Standard Call Factory Call Factory - BME260SA 6 11,712 2, Standard Call Factory Call Factory - BME310SA 6 13,419 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 15,843 2, Standard Call Factory 771 1,238 Call Factory - BML100SA 4.5 5,609 2, Standard Call Factory Call Factory - BML165SA 4.5 8,313 2, Standard Call Factory Call Factory - BML220SA ,722 2, Standard Call Factory Call Factory - BML250SA ,231 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,318 2, Standard Call Factory 771 1,238 Call Factory Electric Defrost s with EC Motors /1/60 - BME101SA 6 5,191 2, Standard Call Factory Call Factory - BME140SA 6 6,025 2, Standard Call Factory Call Factory - BME190SA 6 8,542 2, Standard Call Factory Call Factory - BME260SA 6 11,225 2, Standard Call Factory Call Factory - BME310SA 6 12,687 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 15,111 2, Standard Call Factory 771 1,238 Call Factory - BML100SA 4.5 5,365 2, Standard Call Factory Call Factory - BML165SA 4.5 7,825 2, Standard Call Factory Call Factory - BML220SA ,234 2, Standard Call Factory Call Factory - BML250SA ,500 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,586 2, Standard Call Factory 771 1,238 Call Factory Electric Defrost s with EC Motors /3/60 - BME101SA 6 5,191 2, Standard Call Factory Call Factory - BME140SA 6 6,025 2, Standard Call Factory Call Factory - BME190SA 6 8,542 2, Standard Call Factory Call Factory - BME260SA 6 11,225 2, Standard Call Factory Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 57 Section 5

63 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow - BME310SA 6 12,687 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 15,111 2, Standard Call Factory 771 1,238 Call Factory - BME430SA 6 16,929 2, Standard Call Factory 771 1,238 Call Factory - BME520SA 6 18,844 2, Standard Call Factory 771 1,238 Call Factory - BME620SA 6 20,718 2, Standard Call Factory 1,117 1,715 Call Factory - BML100SA 4.5 5,365 2, Standard Call Factory Call Factory - BML165SA 4.5 7,825 2, Standard Call Factory Call Factory - BML220SA ,234 2, Standard Call Factory Call Factory - BML250SA ,500 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,586 2, Standard Call Factory 771 1,238 Call Factory - BML370SA ,359 2, Standard Call Factory 771 1,238 Call Factory - BML440SA ,161 2, Standard Call Factory 771 1,238 Call Factory - BML530SA ,024 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with PSC Motors /1/60 BME101BA BME101SA 6 4,526 2, Standard Call Factory Call Factory BME140BA BME140SA 6 5,360 2, Standard Call Factory Call Factory BME190BA BME190SA 6 7,212 2, Standard Call Factory Call Factory BME260BA BME260SA 6 9,895 2, Standard Call Factory Call Factory BME310BA BME310SA 6 10,692 2, Standard Call Factory 771 1,238 Call Factory BME390BA BME390SA 6 13,116 2, Standard Call Factory 771 1,238 Call Factory BML100BA BML100SA 4.5 4,700 2, Standard Call Factory Call Factory BML165BA BML165SA 4.5 6,495 2, Standard Call Factory Call Factory BML220BA BML220SA 4.5 8,904 2, Standard Call Factory Call Factory BML250BA BML250SA 4.5 9,505 2, Standard Call Factory 771 1,238 Call Factory BML330BA BML330SA ,591 2, Standard Call Factory 771 1,238 Call Factory Electric Defrost s with PSC Motors /3/60 BME101CA BME101SA 6 4,526 2, Standard Call Factory Call Factory BME140CA BME140SA 6 5,360 2, Standard Call Factory Call Factory BME190CA BME190SA 6 7,212 2, Standard Call Factory Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 58 Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

64 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow BME260CA BME260SA 6 9,895 2, Standard Call Factory Call Factory BME310CA BME310SA 6 10,692 2, Standard Call Factory 771 1,238 Call Factory BME390CA BME390SA 6 13,116 2, Standard Call Factory 771 1,238 Call Factory BME430CA BME430SA 6 14,269 2, Standard Call Factory 771 1,238 Call Factory BME520CA BME520SA 6 16,184 2, Standard Call Factory 771 1,238 Call Factory BME620CA BME620SA 6 17,393 2, Standard Call Factory 1,117 1,715 Call Factory BML100CA BML100SA 4.5 4,700 2, Standard Call Factory Call Factory BML165CA BML165SA 4.5 6,495 2, Standard Call Factory Call Factory BML220CA BML220SA 4.5 8,904 2, Standard Call Factory Call Factory BML250CA BML250SA 4.5 9,505 2, Standard Call Factory 771 1,238 Call Factory BML330CA BML330SA ,591 2, Standard Call Factory 771 1,238 Call Factory BML370CA BML370SA ,699 2, Standard Call Factory 771 1,238 Call Factory BML440CA BML440SA ,501 2, Standard Call Factory 771 1,238 Call Factory BML530CA BML530SA ,699 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with PSC Motors - 460/1/60 BME101MA BME101SA 6 4,799 2, Standard Call Factory Call Factory BME140MA BME140SA 6 5,632 2, Standard Call Factory Call Factory BME190MA BME190SA 6 7,748 2, Standard Call Factory Call Factory BME260MA BME260SA 6 10,432 2, Standard Call Factory Call Factory BME310MA BME310SA 6 11,496 2, Standard Call Factory 771 1,238 Call Factory BME390MA BME390SA 6 13,922 2, Standard Call Factory 771 1,238 Call Factory BME430MA BME430SA 6 15,343 2, Standard Call Factory 771 1,238 Call Factory BME520MA BME520SA 6 17,259 2, Standard Call Factory 771 1,238 Call Factory BME620MA BME620SA 6 18,738 2, Standard Call Factory 1,117 1,715 Call Factory BML100MA BML100SA 4.5 4,967 2, Standard Call Factory Call Factory BML165MA BML165SA 4.5 7,032 2, Standard Call Factory Call Factory BML220MA BML220SA 4.5 9,445 2, Standard Call Factory Call Factory BML250MA BML250SA ,039 2, Standard Call Factory 771 1,238 Call Factory BML330MA BML330SA ,399 2, Standard Call Factory 771 1,238 Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 59 Section 5

65 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow BML370MA BML370SA ,771 2, Standard Call Factory 771 1,238 Call Factory BML440MA BML440SA ,572 2, Standard Call Factory 771 1,238 Call Factory BML530MA BML530SA ,041 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with PSC Motors - 460/3/60 BME101DA BME101SA 6 4,799 2, Standard Call Factory Call Factory BME140DA BME140SA 6 5,632 2, Standard Call Factory Call Factory BME190DA BME190SA 6 7,748 2, Standard Call Factory Call Factory BME260DA BME260SA 6 10,432 2, Standard Call Factory Call Factory BME310DA BME310SA 6 11,496 2, Standard Call Factory 771 1,238 Call Factory BME390DA BME390SA 6 13,922 2, Standard Call Factory 771 1,238 Call Factory BME430DA BME430SA 6 15,343 2, Standard Call Factory 771 1,238 Call Factory BME520DA BME520SA 6 17,259 2, Standard Call Factory 771 1,238 Call Factory BME620DA BME620SA 6 18,738 2, Standard Call Factory 1,117 1,715 Call Factory BML100DA BML100SA 4.5 4,967 2, Standard Call Factory Call Factory BML165DA BML165SA 4.5 7,032 2, Standard Call Factory Call Factory BML220DA BML220SA 4.5 9,445 2, Standard Call Factory Call Factory BML250DA BML250SA ,039 2, Standard Call Factory 771 1,238 Call Factory BML330DA BML330SA ,399 2, Standard Call Factory 771 1,238 Call Factory BML370DA BML370SA ,771 2, Standard Call Factory 771 1,238 Call Factory BML440DA BML440SA ,572 2, Standard Call Factory 771 1,238 Call Factory BML530DA BML530SA ,041 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with PSC Motors - 575/3/60 BME101EA BME101SA 6 4,897 2, Standard Call Factory Call Factory BME140EA BME140SA 6 5,742 2, Standard Call Factory Call Factory BME190EA BME190SA 6 7,902 2, Standard Call Factory Call Factory BME260EA BME260SA 6 10,644 2, Standard Call Factory Call Factory BME310EA BME310SA 6 11,727 2, Standard Call Factory 771 1,238 Call Factory BME390EA BME390SA 6 14,201 2, Standard Call Factory 771 1,238 Call Factory BME430EA BME430SA 6 15,653 2, Standard Call Factory 771 1,238 Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 60 Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

66 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow BME520EA BME520SA 6 17,603 2, Standard Call Factory 771 1,238 Call Factory BME620EA BME620SA 6 19,113 2, Standard Call Factory 1,117 1,715 Call Factory BML100EA BML100SA 4.5 5,068 2, Standard Call Factory Call Factory BML165EA BML165SA 4.5 7,170 2, Standard Call Factory Call Factory BML220EA BML220SA 4.5 9,634 2, Standard Call Factory Call Factory BML250EA BML250SA ,239 2, Standard Call Factory 771 1,238 Call Factory BML330EA BML330SA ,668 2, Standard Call Factory 771 1,238 Call Factory BML370EA BML370SA ,068 2, Standard Call Factory 771 1,238 Call Factory BML440EA BML440SA ,903 2, Standard Call Factory 771 1,238 Call Factory BML530EA BML530SA ,400 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with Totally-Enclosed PSC Motors /1/60 - BME101SA 6 4,780 2, Standard Call Factory Call Factory - BME140SA 6 5,614 2, Standard Call Factory Call Factory - BME190SA 6 7,720 2, Standard Call Factory Call Factory - BME260SA 6 10,403 2, Standard Call Factory Call Factory - BME310SA 6 11,454 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 13,878 2, Standard Call Factory 771 1,238 Call Factory - BML100SA 4.5 4,954 2, Standard Call Factory Call Factory - BML165SA 4.5 7,003 2, Standard Call Factory Call Factory - BML220SA 4.5 9,412 2, Standard Call Factory Call Factory - BML250SA ,267 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,353 2, Standard Call Factory 771 1,238 Call Factory Electric Defrost s with Totally-Enclosed PSC Motors /3/60 - BME101SA 6 4,780 2, Standard Call Factory Call Factory - BME140SA 6 5,614 2, Standard Call Factory Call Factory - BME190SA 6 7,720 2, Standard Call Factory Call Factory - BME260SA 6 10,403 2, Standard Call Factory Call Factory - BME310SA 6 11,454 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 13,878 2, Standard Call Factory 771 1,238 Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 61 Section 5

67 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow - BME430SA 6 15,285 2, Standard Call Factory 771 1,238 Call Factory - BME520SA 6 17,200 2, Standard Call Factory 771 1,238 Call Factory - BME620SA 6 18,663 2, Standard Call Factory 1,117 1,715 Call Factory - BML100SA 4.5 4,954 2, Standard Call Factory Call Factory - BML165SA 4.5 7,003 2, Standard Call Factory Call Factory - BML220SA 4.5 9,412 2, Standard Call Factory Call Factory - BML250SA ,267 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,353 2, Standard Call Factory 771 1,238 Call Factory - BML370SA ,715 2, Standard Call Factory 771 1,238 Call Factory - BML440SA ,517 2, Standard Call Factory 771 1,238 Call Factory - BML530SA ,969 2, Standard Call Factory 1,117 1,715 Call Factory Electric Defrost s with Totally-Enclosed PSC Motors - 460/1/60 - BME101SA 6 5,053 2, Standard Call Factory Call Factory - BME140SA 6 5,886 2, Standard Call Factory Call Factory - BME190SA 6 8,256 2, Standard Call Factory Call Factory - BME260SA 6 10,940 2, Standard Call Factory Call Factory - BME310SA 6 12,258 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 14,684 2, Standard Call Factory 771 1,238 Call Factory - BME430SA 6 16,359 2, Standard Call Factory 771 1,238 Call Factory - BME520SA 6 18,275 2, Standard Call Factory 771 1,238 Call Factory - BME620SA 6 20,008 2, Standard Call Factory 1,117 1,715 Call Factory - BML100SA 4.5 5,221 2, Standard Call Factory Call Factory - BML165SA 4.5 7,540 2, Standard Call Factory Call Factory - BML220SA 4.5 9,953 2, Standard Call Factory Call Factory - BML250SA ,801 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,161 2, Standard Call Factory 771 1,238 Call Factory - BML370SA ,787 2, Standard Call Factory 771 1,238 Call Factory - BML440SA ,588 2, Standard Call Factory 771 1,238 Call Factory - BML530SA ,311 2, Standard Call Factory 1,117 1,715 Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 62 Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

68 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electrical Options Beacon II Assembly Factory-Installed Options Adders Room TSTAT Electric Defrost s with Totally-Enclosed PSC Motors - 460/3/60 Drain Pan Options Electric Double Wall Insulated Mechanical Options TXV TXV & LLSV Coil Options Bronz-Glow - BME101SA 6 5,053 2, Standard Call Factory Call Factory - BME140SA 6 5,886 2, Standard Call Factory Call Factory - BME190SA 6 8,256 2, Standard Call Factory Call Factory - BME260SA 6 10,940 2, Standard Call Factory Call Factory - BME310SA 6 12,258 2, Standard Call Factory 771 1,238 Call Factory - BME390SA 6 14,684 2, Standard Call Factory 771 1,238 Call Factory - BME430SA 6 16,359 2, Standard Call Factory 771 1,238 Call Factory - BME520SA 6 18,275 2, Standard Call Factory 771 1,238 Call Factory - BME620SA 6 20,008 2, Standard Call Factory 1,117 1,715 Call Factory - BML100SA 4.5 5,221 2, Standard Call Factory Call Factory - BML165SA 4.5 7,540 2, Standard Call Factory Call Factory - BML220SA 4.5 9,953 2, Standard Call Factory Call Factory - BML250SA ,801 2, Standard Call Factory 771 1,238 Call Factory - BML330SA ,161 2, Standard Call Factory 771 1,238 Call Factory - BML370SA ,787 2, Standard Call Factory 771 1,238 Call Factory - BML440SA ,588 2, Standard Call Factory 771 1,238 Call Factory - BML530SA ,311 2, Standard Call Factory 1,117 1,715 Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Fixed Defrost Termination/Fan Delay standard. Beacon II must be ordered as a system. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Molded fan guards are standard and wire fan guards optional at no additional cost. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 63 Section 5

69 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electric Hot Gas Defrost s with VSEC Motors - 115/1/60 Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow - BMG190SA 6 8,490 Standard 686 Call Factory Call Factory - BMG260SA 6 10,954 Standard 686 Call Factory Call Factory - BMG310SA 6 12,613 Standard 824 Call Factory Call Factory - BMG390SA 6 14,904 Standard 824 Call Factory Call Factory - BMG430SA 6 16,832 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 18,636 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 8,284 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA ,739 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,312 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,467 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,358 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,102 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with VSEC Motors /1/60 - BMG190SA 6 8,625 Standard 686 Call Factory Call Factory - BMG260SA 6 11,156 Standard 686 Call Factory Call Factory - BMG310SA 6 12,813 Standard 824 Call Factory Call Factory - BMG390SA 6 15,105 Standard 824 Call Factory Call Factory - BMG430SA 6 17,101 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 18,904 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 8,418 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA ,875 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,509 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,669 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,629 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,374 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with EC Motors - 115/1/60 - BMG190SA 6 8,002 Standard 686 Call Factory Call Factory - BMG260SA 6 10,466 Standard 686 Call Factory Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 64 Notes: Adjustable Defrost Term/Fan Relay standard. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve Molded fan guards are standard and wire fan guards optional at no additional cost. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

70 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow - BMG310SA 6 11,881 Standard 824 Call Factory Call Factory - BMG390SA 6 14,172 Standard 824 Call Factory Call Factory - BMG430SA 6 15,856 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 17,660 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 7,796 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA ,251 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,580 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,735 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,382 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,126 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with EC Motors /1/60 - BMG190SA 6 8,137 Standard 686 Call Factory Call Factory - BMG260SA 6 10,668 Standard 686 Call Factory Call Factory - BMG310SA 6 12,081 Standard 824 Call Factory Call Factory - BMG390SA 6 14,373 Standard 824 Call Factory Call Factory - BMG430SA 6 16,125 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 17,928 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 7,930 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA ,387 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,777 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,937 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,653 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,398 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 115/1/60 BMG190AA BMG190SA 6 6,672 Standard 686 Call Factory Call Factory BMG260AA BMG260SA 6 9,136 Standard 686 Call Factory Call Factory BMG310AA BMG310SA 6 9,886 Standard 824 Call Factory Call Factory BMG390AA BMG390SA 6 12,177 Standard 824 Call Factory Call Factory BMG430AA BMG430SA 6 13,196 Standard 960 Call Factory 1,117 - Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Adjustable Defrost Term/Fan Delay standard. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve Molded fan guards are standard and wire fan guards optional at no additional cost. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 65 Section 5

71 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow BMG520AA BMG520SA 6 15,000 Standard 960 Call Factory 1,117 - Call Factory BMF165AA BMF165SA 4.5 6,466 Standard 686 Call Factory 574 Call Factory Call Factory BMF220AA BMF220SA 4.5 8,921 Standard 686 Call Factory 574 Call Factory Call Factory BMF250AA BMF250SA 4.5 9,585 Standard 824 Call Factory 771 Call Factory Call Factory BMF330AA BMF330SA ,740 Standard 824 Call Factory 771 Call Factory Call Factory BMF370AA BMF370SA ,722 Standard 960 Call Factory 1,117 Call Factory Call Factory BMF440AA BMF440SA ,466 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with PSC Motors /1/60 BMG190BA BMG190SA 6 6,807 Standard 686 Call Factory Call Factory BMG260BA BMG260SA 6 9,338 Standard 686 Call Factory Call Factory BMG310BA BMG310SA 6 10,086 Standard 824 Call Factory Call Factory BMG390BA BMG390SA 6 12,378 Standard 824 Call Factory Call Factory BMG430BA BMG430SA 6 13,465 Standard 960 Call Factory 1,117 - Call Factory BMG520BA BMG520SA 6 15,268 Standard 960 Call Factory 1,117 - Call Factory BMF165BA BMF165SA 4.5 6,600 Standard 686 Call Factory 574 Call Factory Call Factory BMF220BA BMF220SA 4.5 9,057 Standard 686 Call Factory 574 Call Factory Call Factory BMF250BA BMF250SA 4.5 9,782 Standard 824 Call Factory 771 Call Factory Call Factory BMF330BA BMF330SA ,942 Standard 824 Call Factory 771 Call Factory Call Factory BMF370BA BMF370SA ,993 Standard 960 Call Factory 1,117 Call Factory Call Factory BMF440BA BMF440SA ,738 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 460/1/60 BMG190MA BMG190SA 6 7,355 Standard 686 Call Factory Call Factory BMG260MA BMG260SA 6 9,885 Standard 686 Call Factory Call Factory BMG310MA BMG310SA 6 10,910 Standard 824 Call Factory Call Factory BMG390MA BMG390SA 6 13,215 Standard 824 Call Factory Call Factory BMG430MA BMG430SA 6 14,557 Standard 960 Call Factory 1,117 - Call Factory BMG520MA BMG520SA 6 16,364 Standard 960 Call Factory 1,117 - Call Factory BMF165MA BMF165SA 4.5 7,144 Standard 686 Call Factory 574 Call Factory Call Factory BMF220MA BMF220SA 4.5 9,605 Standard 686 Call Factory 574 Call Factory Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 66 Notes: Adjustable Defrost Term/Fan Delay standard. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve Molded fan guards are standard and wire fan guards optional at no additional cost. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

72 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow BMF250MA BMF250SA ,607 Standard 824 Call Factory 771 Call Factory Call Factory BMF330MA BMF330SA ,784 Standard 824 Call Factory 771 Call Factory Call Factory BMF370MA BMF370SA ,085 Standard 960 Call Factory 1,117 Call Factory Call Factory BMF440MA BMF440SA ,830 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with PSC Motors - 575/1/60 BMG190LA BMG190SA 6 7,500 Standard 686 Call Factory Call Factory BMG260LA BMG260SA 6 10,082 Standard 686 Call Factory Call Factory BMG310LA BMG310SA 6 11,128 Standard 824 Call Factory Call Factory BMG390LA BMG390SA 6 13,482 Standard 824 Call Factory Call Factory BMG430LA BMG430SA 6 14,850 Standard 960 Call Factory 1,117 - Call Factory BMG520LA BMG520SA 6 16,692 Standard 960 Call Factory 1,117 - Call Factory BMF165LA BMF165SA 4.5 7,288 Standard 686 Call Factory 574 Call Factory Call Factory BMF220LA BMF220SA 4.5 9,798 Standard 686 Call Factory 574 Call Factory Call Factory BMF250LA BMF250SA ,819 Standard 824 Call Factory 771 Call Factory Call Factory BMF330LA BMF330SA ,038 Standard 824 Call Factory 771 Call Factory Call Factory BMF370LA BMF370SA ,368 Standard 960 Call Factory 1,117 Call Factory Call Factory BMF440LA BMF440SA ,148 Standard 960 Call Factory 1,117 Call Factory Call Factory Hot Gas Defrost s with Totally-Enclosed PSC Motors /1/60 - BMG190SA 6 7,315 Standard 686 Call Factory Call Factory - BMG260SA 6 9,846 Standard 686 Call Factory Call Factory - BMG310SA 6 10,848 Standard 824 Call Factory Call Factory - BMG390SA 6 13,140 Standard 824 Call Factory Call Factory - BMG430SA 6 14,481 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 16,284 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 7,108 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA 4.5 9,565 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,544 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,704 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,009 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,754 Standard 960 Call Factory 1,117 Call Factory Call Factory Section 1 Rev. 01/18 Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. Notes: Adjustable Defrost Term/Fan Delay standard. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve Molded fan guards are standard and wire fan guards optional at no additional cost. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 67 Section 5

73 Walk-In Unit Coolers Medium Profile When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable FPI Electric Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Hot Gas Loop Hot Gas Defrost s with Totally-Enclosed PSC Motors - 460/1/60 Double Wall Insulated TXV ElectroFin Coil Bronz-Glow - BMG190SA 6 7,863 Standard 686 Call Factory Call Factory - BMG260SA 6 10,393 Standard 686 Call Factory Call Factory - BMG310SA 6 11,672 Standard 824 Call Factory Call Factory - BMG390SA 6 13,977 Standard 824 Call Factory Call Factory - BMG430SA 6 15,573 Standard 960 Call Factory 1,117 - Call Factory - BMG520SA 6 17,380 Standard 960 Call Factory 1,117 - Call Factory - BMF165SA 4.5 7,652 Standard 686 Call Factory 574 Call Factory Call Factory - BMF220SA ,113 Standard 686 Call Factory 574 Call Factory Call Factory - BMF250SA ,369 Standard 824 Call Factory 771 Call Factory Call Factory - BMF330SA ,546 Standard 824 Call Factory 771 Call Factory Call Factory - BMF370SA ,101 Standard 960 Call Factory 1,117 Call Factory Call Factory - BMF440SA ,846 Standard 960 Call Factory 1,117 Call Factory Call Factory Regulations Require EC or VSEC Motors! Federal Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet with single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors and controlled in response to space conditions. 68 Notes: Adjustable Defrost Term/Fan Delay standard. Variable Speed EC (VSEC) motors require a customer supplied 0-10V signal. TXV = Expansion Valve Molded fan guards are standard and wire fan guards optional at no additional cost. When using hot gas defrost units on 0 F degree applications and below, an insulated drain pan is required for models with hot gas drain pans. Low Temp Motors, Stainless Steel Cabinet & Pan, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

74 Walk-In Unit Coolers Medium Profile Need a Hot Gas Reverse Cycle Kit? Hot Gas Reverse Cycle Kits Need help? Please contact your local Sales Representative or Account Engineer for assistance. Kits for s with Standard Electric Pan Hot Gas s Used On BMG BMF Factory-Installed Option Code Adder Shipped-Loose Part Number RCK.EP-1 2, RCK.EP-2 2, Section 1 Notes: Factory-installed kits include expansion valve and TXV bypass check valve assembly. Specify valve model style, refrigerant, and SST on order. Shipped-loose kits include one check valve and piping for TXV bypass around expansion valve. Kit does not include expansion valve. Kits for s with Optional Hot Gas Pan Hot Gas s Used On Factory-Installed BMG BMF Option Code Adder RCK.HGP-1 3, RCK.HGP-2 3, RCK.HGP-3 4, RCK.HGP-4 4,370 Shipped-Loose Part Number ,044 1,283 1,464 1,564 Notes: Factory installed kits included expansion valve, TXV Bypass check valve assembly, suction check valve assembly, and drain pan check valve assembly. Kit does not include hot gas pan price. Specify valve model style, refrigerant, and SST on order. Shipped-loose kits include one check valve and piping for TXV bypass around expansion valve, one check valve and piping for drain pan assembly and one check valve and piping for suction assembly. Kit does not include Hot gas pan pricing. Kit does not include expansion valve. Hot Gas 3-Pipe Kits Available. Contact your local sales representative or Account Engineer for more information. Section 5 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 69

75 Walk-In Unit Coolers Medium Profile Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance Section 1 Part Number Description Notes Room Thermostats Room Thermostat Electronic Room Thermostat Air Sock Collars Collar for Air Sock (18" fan) 239 Must be used with wire fan guards. Must order 1 per fan. Defrost Controls 4267W Adjustable Defrost Control/Fan Delay Switch Electric Defrost Timer (60 Hz) R 30-Amp Contactor 365 Use as fan or heater contactor 5738-N 50-Amp Contactor Obsolete Use Interlink part Check Valves 5890C 7/8" Suction Line Check Valve C 1 1/8" Suction Line Check Valve /8" Suction Line Check Valve F 1 5/8" Suction Line Check Valve Drain Line Heaters 5508Q 6 ft. Drain Line Heater ( V, 42 Watts) P 12 ft. Drain Line Heater ( V, 84 Watts) P 18 ft. Drain Line Heater ( V, 126 Watts) P 36 ft. Drain Line Heater ( V, 252 Watts) P 60 ft. Drain Line Heater ( V, 420 Watts) Heat Exchangers Heat Exchanger used on 130 Air Defrost and 100-3/8" Liquid Connection OD, 7/8" Suction Connecction OD, Electric Defrost s 14" Length, 2lbs Approx. Ship Wt Heat Exchanger used on Air Defrost s and 1/2" Liquid Connection OD, 1 1/8" Suction Connecction Electric & Hot Gas Defrost s OD, 14" Length, 2lbs Approx. Ship Wt. Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature Heat Exchanger used on Air Defrost s, (6 FPI) Electric & Hot Gas Defrost s, and (4 FPI) Electric & Hot Gas Defrost s Heat Exchanger used on Air Defrost s and Electric & Hot Gas Defrost s Part Capacity Range (BTUH) Number TXV ,000 BTUH and under TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH TXV ,000 BTUH to 120,000 BTUH TXV ,000 BTUH to 360,000 BTUH Liquid-line Solenoid Valves (LLSV) Capacity Range (R-404A) Part Size Medium Temperature Application Low Temperature Application Number (BTUH) (BTUH) /8 12,000 BTUH and under 11,000 BTUH and under 4502Z 323 3/8 12,000 BTUH to 24,000 BTUH 11,000 BTUH to 21,000 BTUH /8 24,000 BTUH to 44,000 BTUH 21,000 BTUH to 38,000 BTUH /2 36,000 BTUH to 51,000 BTUH 31,000 BTUH to 44,000 BTUH 5766Y 349 1/2 51,000 BTUH to 72,000 BTUH 44,000 BTUH to 62,000 BTUH 5768Y 463 5/8 72,000 BTUH to 144,000 BTUH 62,000 BTUH to 120,000 BTUH /8" Liquid Connection OD, 1 3/8" Suction Connecction OD, 14" Length, 3lbs Approx. Ship Wt. 7/8" Liquid Connection OD, 1 5/8" Suction Connecction OD, 16" Length, 4lbs Approx. Ship Wt. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

76 Refrigerated Warehouse Unit Coolers Large Unit Coolers Overview Product Description The large unit cooler line, available in air, electric, and hot gas defrost, is ideal for warehouse cooler/ freezer applications. These superior quality, heavy duty evaporators are available in a wide range of capacities to support many applications. Opting for EC motors or the Beacon II Refrigeration System makes this product qualified to be included in the E Solutions product portfolio because of increased energy efficiency and cost savings. Standard Features Ease of Installation & Service Liquid line solenoid wiring harness for faster installation Standardized terminal board for easier field wiring Hinged drain pan and access panels for easy servicing Suction Schrader fitting for easier suction temperature measurement Captive fasteners on access panels for easy servicing no fumbling with loose bolts and nuts Reliable & Durable Thermo-Flex (with five-year limited warranty) is innovative, eliminates leaks, and reduces risk of refrigerant loss Mill finish aluminum provides an attractive design and structurally sound cabinet PVC coated steel wire fan guards Performance 850 rpm motors are quiet and reliable Long air throw is ideal for large warehouse and industrial application High CFM motors Versatile Adjustable defrost control can be customized per application Available with air, electric, or hot gas defrost Beacon II compatible Many motors and voltages available Section 1 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 71

77 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT TXV Air Defrost s with Totally Enclosed VFD Approved Motors /3/60 TXV & LLSV ElectroFin Coil Guard Fin Protection Bronz-Glow - BHA520SA 12,766 4, ,026 1,595 Call Factory 1,361 Call Factory - BHA630SA 14,073 4, ,026 1,595 Call Factory 1,361 Call Factory - BHA750SA 17,339 4, ,026 1,595 Call Factory 1,445 Call Factory - BHA850SA 18,651 4, ,026 1,595 Call Factory 1,445 Call Factory - BHA930SA 20,441 4, ,217 1,927 Call Factory 1,555 Call Factory - BHA1100SA 22,244 4, ,217 1,927 Call Factory 1,555 Call Factory - BHA1170SA 27,238 4, ,217 1,927 Call Factory 1,664 Call Factory - BHA1400SA 30,516 4, ,217 1,927 Call Factory 1,664 Call Factory - BHA1610SA 32,156 Call Factory 303 1,500 Call Factory Call Factory 1,664 Call Factory - BHA1900SA 37,736 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2160SA 41,669 Call Factory 303 1,330 2,124 Call Factory 1,967 Call Factory - BHA2200SA 41,124 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2440SA 47,522 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2500SA 46,208 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory - BHA2780SA 49,652 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory Air Defrost s with Totally Enclosed VFD Approved Motors - 460/3/60 - BHA520SA 12,766 4, ,026 1,595 Call Factory 1,361 Call Factory - BHA630SA 14,073 4, ,026 1,595 Call Factory 1,361 Call Factory - BHA750SA 17,339 4, ,026 1,595 Call Factory 1,445 Call Factory - BHA850SA 18,651 4, ,026 1,595 Call Factory 1,445 Call Factory - BHA930SA 20,441 4, ,217 1,927 Call Factory 1,555 Call Factory - BHA1100SA 22,244 4, ,217 1,927 Call Factory 1,555 Call Factory - BHA1170SA 27,238 4, ,217 1,927 Call Factory 1,664 Call Factory - BHA1400SA 30,516 4, ,217 1,927 Call Factory 1,664 Call Factory - BHA1610SA 32,156 Call Factory 303 1,500 Call Factory Call Factory 1,664 Call Factory - BHA1900SA 37,736 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2160SA 41,669 Call Factory 303 1,330 2,124 Call Factory 1,967 Call Factory - BHA2200SA 41,124 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2440SA 47,522 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory - BHA2500SA 46,208 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory - BHA2780SA 49,652 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Beacon II must be ordered as a system. s 1610, 2440, 2500, 2780 and the models 1900, 2160, 2200 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 72 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

78 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Air Defrost s with Standard Motors /1/60 TXV TXV & LLSV ElectroFin Coil Guard Fin Protection Bronz-Glow BHA520BA BHA520SA 11,812 4, ,026 1,595 Call Factory 1,361 Call Factory BHA630BA BHA630SA 13,120 4, ,026 1,595 Call Factory 1,361 Call Factory BHA750BA BHA750SA 15,911 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850BA BHA850SA 17,223 4, ,026 1,595 Call Factory 1,445 Call Factory BHA930BA BHA930SA 18,537 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100BA BHA1100SA 20,340 4, ,217 1,927 Call Factory 1,555 Call Factory Air Defrost s with Standard Motors /3/60 BHA520CPA BHA520SA 12,548 4, ,026 1,595 Call Factory 1,361 Call Factory BHA630CPA BHA630SA 14,028 4, ,026 1,595 Call Factory 1,361 Call Factory BHA750CA BHA750SA 15,911 4, ,026 1,595 Call Factory 1,445 Call Factory BHA750CPA BHA750SA 17,044 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850CA BHA850SA 17,223 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850CPA BHA850SA 18,308 4, ,026 1,595 Call Factory 1,445 Call Factory BHA930CA BHA930SA 18,537 4, ,217 1,927 Call Factory 1,555 Call Factory BHA930CPA BHA930SA 20,011 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100CA BHA1100SA 20,340 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100CPA BHA1100SA 21,817 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1170CPA BHA1170SA 26,413 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1400CPA BHA1400SA 29,691 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1610CPA BHA1610SA 31,331 Call Factory 303 1,500 Call Factory Call Factory 1,664 Call Factory BHA1900CPA BHA1900SA 36,911 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2160CPA BHA2160SA 40,844 Call Factory 303 1,330 2,124 Call Factory 1,967 Call Factory BHA2200CPA BHA2200SA 40,024 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2440CPA BHA2440SA 46,422 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2500CPA BHA2500SA 45,108 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory BHA2780CPA BHA2780SA 48,552 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory Air Defrost s with Standard Motors - 460/1/60 BHA520MA BHA520SA 11,812 4, ,026 1,595 Call Factory 1,361 Call Factory BHA630MA BHA630SA 13,120 4, ,026 1,595 Call Factory 1,361 Call Factory Air Defrost s with Standard Motors - 460/3/60 BHA520DPA BHA520SA 12,548 4, ,026 1,595 Call Factory 1,361 Call Factory BHA630DPA BHA630SA 14,028 4, ,026 1,595 Call Factory 1,361 Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Beacon II must be ordered as a system. s 1610, 2440, 2500, 2780 and the models 1900, 2160, 2200 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 73

79 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT TXV TXV & LLSV ElectroFin Coil Guard Fin Protection Bronz-Glow BHA750DA BHA750SA 15,911 4, ,026 1,595 Call Factory 1,445 Call Factory BHA750DPA BHA750SA 17,044 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850DA BHA850SA 17,223 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850DPA BHA850SA 18,308 4, ,026 1,595 Call Factory 1,445 Call Factory BHA930DA BHA930SA 18,537 4, ,217 1,927 Call Factory 1,555 Call Factory BHA930DPA BHA930SA 20,011 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100DA BHA1100SA 20,340 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100DPA BHA1100SA 21,817 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1170DPA BHA1170SA 26,413 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1400DPA BHA1400SA 29,691 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1610DPA BHA1610SA 31,331 Call Factory 303 1,500 Call Factory Call Factory 1,664 Call Factory BHA1900DPA BHA1900SA 36,911 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2160DPA BHA2160SA 40,844 Call Factory 303 1,330 2,124 Call Factory 1,967 Call Factory BHA2200DPA BHA2200SA 40,024 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2440DPA BHA2440SA 46,422 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2500DPA BHA2500SA 45,108 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory BHA2780DPA BHA2780SA 48,552 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory Air Defrost s with Standard Motors - 575/3/60 BHA520EPA BHA520SA 12,799 4, ,026 1,595 Call Factory 1,361 Call Factory BHA630EPA BHA630SA 14,307 4, ,026 1,595 Call Factory 1,361 Call Factory BHA750EPA BHA750SA 17,385 4, ,026 1,595 Call Factory 1,445 Call Factory BHA850EPA BHA850SA 18,673 4, ,026 1,595 Call Factory 1,445 Call Factory BHA930EPA BHA930SA 20,411 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1100EPA BHA1100SA 22,253 4, ,217 1,927 Call Factory 1,555 Call Factory BHA1170EPA BHA1170SA 26,939 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1400EPA BHA1400SA 30,284 4, ,217 1,927 Call Factory 1,664 Call Factory BHA1610EPA BHA1610SA 31,957 Call Factory 303 1,500 Call Factory Call Factory 1,664 Call Factory BHA1900EPA BHA1900SA 37,646 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2160EPA BHA2160SA 41,661 Call Factory 303 1,330 2,124 Call Factory 1,967 Call Factory BHA2200EPA BHA2200SA 40,824 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2440EPA BHA2440SA 47,353 Call Factory 303 1,330 2,124 Call Factory 2,676 Call Factory BHA2500EPA BHA2500SA 46,013 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory BHA2780EPA BHA2780SA 49,461 Call Factory 303 1,330 2,124 Call Factory 2,182 Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Beacon II must be ordered as a system. s 1610, 2440, 2500, 2780 and the models 1900, 2160, 2200 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve Double Wall Insulated Pans, Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 74 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

80 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated Electric Defrost s with Totally Enclosed VFD Approved Motors /3/60 TXV TXV & LLSV Bronz-Glow - BHE450SA 14,896 4, Standard Call Factory 1,026 1,595 Call Factory - BHE550SA 17,027 4, Standard Call Factory 1,026 1,595 Call Factory - BHE640SA 18,980 4, Standard Call Factory 1,026 1,595 Call Factory - BHE740SA 22,258 4, Standard Call Factory 1,026 1,595 Call Factory - BHE810SA 27,162 4, Standard Call Factory 1,217 1,927 Call Factory - BHE950SA 29,466 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1020SA 30,516 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1200SA 34,780 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1390SA 38,061 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHE1650SB 49,052 4, Standard Call Factory 1,217 2,124 Call Factory - BHE2120SB 59,989 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory - BHL400SA 13,909 4, Standard Call Factory 1,026 1,595 Call Factory - BHL480SA 16,863 4, Standard Call Factory 1,026 1,595 Call Factory - BHL560SA 18,651 4, Standard Call Factory 1,026 1,595 Call Factory - BHL650SA 20,457 4, Standard Call Factory 1,026 1,595 Call Factory - BHL710SA 22,410 4, Standard Call Factory 1,217 1,927 Call Factory - BHL840SA 28,971 4, Standard Call Factory 1,217 1,927 Call Factory - BHL890SA 30,185 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1050SA 34,127 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1220SA 37,736 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHL1440SB 47,411 4, Standard Call Factory 1,217 2,124 Call Factory - BHL1860SB 57,364 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with Totally Enclosed VFD Approved Motors - 460/3/60 - BHE450SA 14,896 4, Standard Call Factory 1,026 1,595 Call Factory - BHE550SA 17,027 4, Standard Call Factory 1,026 1,595 Call Factory - BHE640SA 18,980 4, Standard Call Factory 1,026 1,595 Call Factory - BHE740SA 22,258 4, Standard Call Factory 1,026 1,595 Call Factory - BHE810SA 27,162 4, Standard Call Factory 1,217 1,927 Call Factory - BHE950SA 29,466 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1020SA 30,516 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1200SA 34,780 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1390SA 38,061 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 75

81 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated TXV TXV & LLSV Bronz-Glow - BHE1650SB 49,052 4, Standard Call Factory 1,217 2,124 Call Factory - BHE2120SB 59,989 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory - BHL400SA 13,909 4, Standard Call Factory 1,026 1,595 Call Factory - BHL480SA 16,863 4, Standard Call Factory 1,026 1,595 Call Factory - BHL560SA 18,651 4, Standard Call Factory 1,026 1,595 Call Factory - BHL650SA 20,457 4, Standard Call Factory 1,026 1,595 Call Factory - BHL710SA 22,410 4, Standard Call Factory 1,217 1,927 Call Factory - BHL840SA 28,971 4, Standard Call Factory 1,217 1,927 Call Factory - BHL890SA 30,185 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1050SA 34,127 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1220SA 37,736 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHL1440SB 47,411 4, Standard Call Factory 1,217 2,124 Call Factory - BHL1860SB 57,364 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with Standard Motors /3/60 BHE450CA BHE450SA 13,944 4, Standard Call Factory 1,026 1,595 Call Factory BHE450CPA BHE450SA 14,682 4, Standard Call Factory 1,026 1,595 Call Factory BHE550CA BHE550SA 16,075 4, Standard Call Factory 1,026 1,595 Call Factory BHE550CPA BHE550SA 16,799 4, Standard Call Factory 1,026 1,595 Call Factory BHE640CA BHE640SA 17,552 4, Standard Call Factory 1,026 1,595 Call Factory BHE640CPA BHE640SA 18,636 4, Standard Call Factory 1,026 1,595 Call Factory BHE740CA BHE740SA 20,830 4, Standard Call Factory 1,026 1,595 Call Factory BHE740CPA BHE740SA 21,980 4, Standard Call Factory 1,026 1,595 Call Factory BHE810CA BHE810SA 25,258 4, Standard Call Factory 1,217 1,927 Call Factory BHE810CPA BHE810SA 26,705 4, Standard Call Factory 1,217 1,927 Call Factory BHE950CA BHE950SA 27,562 4, Standard Call Factory 1,217 1,927 Call Factory BHE950CPA BHE950SA 29,035 4, Standard Call Factory 1,217 1,927 Call Factory BHE1020CPA BHE1020SA 29,691 4, Standard Call Factory 1,217 1,927 Call Factory BHE1200CPA BHE1200SA 33,955 4, Standard Call Factory 1,217 1,927 Call Factory BHE1390CPA BHE1390SA 37,236 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHE1650CPB BHE1650SB 48,227 4, Standard Call Factory 1,217 2,124 Call Factory BHE2120CPB BHE2120SB 58,889 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory BHL400CA BHL400SA 12,957 4, Standard Call Factory 1,026 1,595 Call Factory BHL400CPA BHL400SA 13,679 4, Standard Call Factory 1,026 1,595 Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 76 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

82 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated TXV TXV & LLSV Bronz-Glow BHL480CA BHL480SA 15,911 4, Standard Call Factory 1,026 1,595 Call Factory BHL480CPA BHL480SA 16,649 4, Standard Call Factory 1,026 1,595 Call Factory BHL560CA BHL560SA 17,223 4, Standard Call Factory 1,026 1,595 Call Factory BHL560CPA BHL560SA 18,308 4, Standard Call Factory 1,026 1,595 Call Factory BHL650CA BHL650SA 19,029 4, Standard Call Factory 1,026 1,595 Call Factory BHL650CPA BHL650SA 20,109 4, Standard Call Factory 1,026 1,595 Call Factory BHL710CA BHL710SA 20,506 4, Standard Call Factory 1,217 1,927 Call Factory BHL710CPA BHL710SA 21,980 4, Standard Call Factory 1,217 1,927 Call Factory BHL840CA BHL840SA 27,067 4, Standard Call Factory 1,217 1,927 Call Factory BHL840CPA BHL840SA 28,540 4, Standard Call Factory 1,217 1,927 Call Factory BHL890CPA BHL890SA 29,360 4, Standard Call Factory 1,217 1,927 Call Factory BHL1050CPA BHL1050SA 33,302 4, Standard Call Factory 1,217 1,927 Call Factory BHL1220CPA BHL1220SA 36,911 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHL1440CPB BHL1440SB 46,586 4, Standard Call Factory 1,217 2,124 Call Factory BHL1860CPB BHL1860SB 56,264 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with Standard Motors - 460/3/60 BHE450DA BHE450SA 13,944 4, Standard Call Factory 1,026 1,595 Call Factory BHE450DPA BHE450SA 14,682 4, Standard Call Factory 1,026 1,595 Call Factory BHE550DA BHE550SA 16,075 4, Standard Call Factory 1,026 1,595 Call Factory BHE550DPA BHE550SA 16,799 4, Standard Call Factory 1,026 1,595 Call Factory BHE640DA BHE640SA 17,552 4, Standard Call Factory 1,026 1,595 Call Factory BHE640DPA BHE640SA 18,636 4, Standard Call Factory 1,026 1,595 Call Factory BHE740DA BHE740SA 20,830 4, Standard Call Factory 1,026 1,595 Call Factory BHE740DPA BHE740SA 21,980 4, Standard Call Factory 1,026 1,595 Call Factory BHE810DA BHE810SA 25,258 4, Standard Call Factory 1,217 1,927 Call Factory BHE810DPA BHE810SA 26,705 4, Standard Call Factory 1,217 1,927 Call Factory BHE950DA BHE950SA 27,562 4, Standard Call Factory 1,217 1,927 Call Factory BHE950DPA BHE950SA 29,035 4, Standard Call Factory 1,217 1,927 Call Factory BHE1020DPA BHE1020SA 29,691 4, Standard Call Factory 1,217 1,927 Call Factory BHE1200DPA BHE1200SA 33,955 4, Standard Call Factory 1,217 1,927 Call Factory BHE1390DPA BHE1390SA 37,236 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHE1650DPB BHE1650SB 48,227 4, Standard Call Factory 1,217 2,124 Call Factory BHE2120DPB BHE2120SB 58,889 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 77

83 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated TXV TXV & LLSV Bronz-Glow BHL400DA BHL400SA 12,957 4, Standard Call Factory 1,026 1,595 Call Factory BHL400DPA BHL400SA 13,679 4, Standard Call Factory 1,026 1,595 Call Factory BHL480DA BHL480SA 15,911 4, Standard Call Factory 1,026 1,595 Call Factory BHL480DPA BHL480SA 16,649 4, Standard Call Factory 1,026 1,595 Call Factory BHL560DA BHL560SA 17,223 4, Standard Call Factory 1,026 1,595 Call Factory BHL560DPA BHL560SA 18,308 4, Standard Call Factory 1,026 1,595 Call Factory BHL650DA BHL650SA 19,029 4, Standard Call Factory 1,026 1,595 Call Factory BHL650DPA BHL650SA 20,109 4, Standard Call Factory 1,026 1,595 Call Factory BHL710DA BHL710SA 20,506 4, Standard Call Factory 1,217 1,927 Call Factory BHL710DPA BHL710SA 21,980 4, Standard Call Factory 1,217 1,927 Call Factory BHL840DA BHL840SA 27,067 4, Standard Call Factory 1,217 1,927 Call Factory BHL840DPA BHL840SA 28,540 4, Standard Call Factory 1,217 1,927 Call Factory BHL890DPA BHL890SA 29,360 4, Standard Call Factory 1,217 1,927 Call Factory BHL1050DPA BHL1050SA 33,302 4, Standard Call Factory 1,217 1,927 Call Factory BHL1220DPA BHL1220SA 36,911 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHL1440DPB BHL1440SB 46,586 4, Standard Call Factory 1,217 2,124 Call Factory BHL1860DPB BHL1860SB 56,264 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with Standard Motors - 575/3/60 BHE450EPA BHE450SA 14,974 4, Standard Call Factory 1,026 1,595 Call Factory BHE550EPA BHE550SA 17,135 4, Standard Call Factory 1,026 1,595 Call Factory BHE640EPA BHE640SA 19,007 4, Standard Call Factory 1,026 1,595 Call Factory BHE740EPA BHE740SA 22,418 4, Standard Call Factory 1,026 1,595 Call Factory BHE810EPA BHE810SA 27,239 4, Standard Call Factory 1,217 1,927 Call Factory BHE950EPA BHE950SA 29,613 4, Standard Call Factory 1,217 1,927 Call Factory BHE1020EPA BHE1020SA 30,284 4, Standard Call Factory 1,217 1,927 Call Factory BHE1200EPA BHE1200SA 34,633 4, Standard Call Factory 1,217 1,927 Call Factory BHE1390EPA BHE1390SA 37,983 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHE1650EPB BHE1650SB 49,191 4, Standard Call Factory 1,217 2,124 Call Factory BHE2120EPB BHE2120SB 60,065 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory BHL400EPA BHL400SA 13,955 4, Standard Call Factory 1,026 1,595 Call Factory BHL480EPA BHL480SA 16,982 4, Standard Call Factory 1,026 1,595 Call Factory BHL560EPA BHL560SA 18,673 4, Standard Call Factory 1,026 1,595 Call Factory BHL650EPA BHL650SA 20,512 4, Standard Call Factory 1,026 1,595 Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 78 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

84 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated TXV TXV & LLSV Bronz-Glow BHL710EPA BHL710SA 22,418 4, Standard Call Factory 1,217 1,927 Call Factory BHL840EPA BHL840SA 29,111 4, Standard Call Factory 1,217 1,927 Call Factory BHL890EPA BHL890SA 29,948 4, Standard Call Factory 1,217 1,927 Call Factory BHL1050EPA BHL1050SA 33,967 4, Standard Call Factory 1,217 1,927 Call Factory BHL1220EPA BHL1220SA 37,646 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory BHL1440EPB BHL1440SB 47,518 4, Standard Call Factory 1,217 2,124 Call Factory BHL1860EPB BHL1860SB 57,387 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with High CFM Motors /3/60 - BHE450SA 16,814 4, Standard Call Factory 1,026 1,595 Call Factory - BHE550SA 18,945 4, Standard Call Factory 1,026 1,595 Call Factory - BHE640SA 21,857 4, Standard Call Factory 1,026 1,595 Call Factory - BHE740SA 25,135 4, Standard Call Factory 1,026 1,595 Call Factory - BHE810SA 30,998 4, Standard Call Factory 1,217 1,927 Call Factory - BHE950SA 33,302 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1020SA 33,717 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1200SA 37,981 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1390SA 41,262 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHE1650SB 52,253 4, Standard Call Factory 1,217 2,124 Call Factory - BHE2120SB 64,257 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory - BHL400SA 15,827 4, Standard Call Factory 1,026 1,595 Call Factory - BHL480SA 18,781 4, Standard Call Factory 1,026 1,595 Call Factory - BHL560SA 21,528 4, Standard Call Factory 1,026 1,595 Call Factory - BHL650SA 23,334 4, Standard Call Factory 1,026 1,595 Call Factory - BHL710SA 26,246 4, Standard Call Factory 1,217 1,927 Call Factory - BHL840SA 32,807 4, Standard Call Factory 1,217 1,927 Call Factory - BHL890SA 33,386 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1050SA 37,328 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1220SA 40,937 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHL1440SB 50,612 4, Standard Call Factory 1,217 2,124 Call Factory - BHL1860SB 61,632 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Electric Defrost s with High CFM Motors - 460/3/60 - BHE450SA 16,814 4, Standard Call Factory 1,026 1,595 Call Factory - BHE550SA 18,945 4, Standard Call Factory 1,026 1,595 Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 79

85 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Electrical Options Drain Pan Options Mechanical Options Coil Options Beacon II Assembly Room TSTAT Electric Double Wall Insulated TXV TXV & LLSV Bronz-Glow - BHE640SA 21,857 4, Standard Call Factory 1,026 1,595 Call Factory - BHE740SA 25,135 4, Standard Call Factory 1,026 1,595 Call Factory - BHE810SA 30,998 4, Standard Call Factory 1,217 1,927 Call Factory - BHE950SA 33,302 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1020SA 33,717 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1200SA 37,981 4, Standard Call Factory 1,217 1,927 Call Factory - BHE1390SA 41,262 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHE1650SB 52,253 4, Standard Call Factory 1,217 2,124 Call Factory - BHE2120SB 64,257 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory - BHL400SA 15,827 4, Standard Call Factory 1,026 1,595 Call Factory - BHL480SA 18,781 4, Standard Call Factory 1,026 1,595 Call Factory - BHL560SA 21,528 4, Standard Call Factory 1,026 1,595 Call Factory - BHL650SA 23,334 4, Standard Call Factory 1,026 1,595 Call Factory - BHL710SA 26,246 4, Standard Call Factory 1,217 1,927 Call Factory - BHL840SA 32,807 4, Standard Call Factory 1,217 1,927 Call Factory - BHL890SA 33,386 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1050SA 37,328 4, Standard Call Factory 1,217 1,927 Call Factory - BHL1220SA 40,937 Call Factory 303 Standard Call Factory 1,500 Call Factory Call Factory - BHL1440SB 50,612 4, Standard Call Factory 1,217 2,124 Call Factory - BHL1860SB 61,632 Call Factory 303 Standard Call Factory 1,217 2,124 Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Beacon II must be ordered as a system. s 1220, 1390, 1860, and 2120 (when used with 404A) require special split circuiting. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve; LLSV = Liquid Line Solenoid Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 80 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

86 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated Hot Gas Defrost s with Totally Enclosed VFD Approved Motors /3/60 TXV ElectroFin Coil Bronz-Glow - BHG450SA 14,402 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG550SA 16,701 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG640SA 18,486 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG740SA 21,768 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG810SA 26,183 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG950SA 28,971 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG1020SA 29,860 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1200SA 34,287 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1390SA 37,567 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG1650SA 45,933 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG2120SB 57,853 Standard 1,475 Call Factory 1,500 Call Factory Call Factory - BHF400SA 13,584 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF480SA 16,373 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF560SA 18,324 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF650SA 20,289 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF710SA 22,244 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF840SA 28,641 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF890SA 29,860 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1050SA 33,632 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1220SA 37,567 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1440SA 46,919 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1860SB 56,872 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with Totally Enclosed VFD Approved Motors - 460/3/60 - BHG450SA 14,402 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG550SA 16,701 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG640SA 18,486 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG740SA 21,768 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG810SA 26,183 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG950SA 28,971 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG1020SA 29,860 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1200SA 34,287 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1390SA 37,567 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG1650SA 45,933 Standard 1,025 Call Factory 1,500 Call Factory Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 81

87 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow - BHG2120SB 57,853 Standard 1,475 Call Factory 1,500 Call Factory Call Factory - BHF400SA 13,584 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF480SA 16,373 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF560SA 18,324 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF650SA 20,289 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF710SA 22,244 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF840SA 28,641 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF890SA 29,860 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1050SA 33,632 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1220SA 37,567 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1440SA 46,919 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1860SB 56,872 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with Standard Motors /1/60 BHG450BA BHG450SA 13,449 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG550BA BHG550SA 15,748 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF400BA BHF400SA 12,632 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF480BA BHF480SA 15,419 Standard 574 Call Factory 1,026 Call Factory Call Factory Hot Gas Defrost s with Standard Motors /3/60 BHG450CPA BHG450SA 14,189 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG550CPA BHG550SA 16,485 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG640CA BHG640SA 17,058 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG640CPA BHG640SA 18,208 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG740CA BHG740SA 20,340 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG740CPA BHG740SA 21,488 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG810CA BHG810SA 24,279 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG810CPA BHG810SA 25,755 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG950CA BHG950SA 27,067 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG950CPA BHG950SA 28,540 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG1020CPA BHG1020SA 29,035 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1200CPA BHG1200SA 33,462 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1390CPA BHG1390SA 36,742 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHG1650CPA BHG1650SA 45,108 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHG2120CPB BHG2120SB 56,753 Standard 1,475 Call Factory 1,500 Call Factory Call Factory BHF400CPA BHF400SA 13,368 Standard 574 Call Factory 1,026 Call Factory Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 82 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

88 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow BHF480CPA BHF480SA 16,161 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF560CA BHF560SA 16,896 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF560CPA BHF560SA 18,043 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF650CA BHF650SA 18,861 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF650CPA BHF650SA 20,011 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF710CA BHF710SA 20,340 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF710CPA BHF710SA 21,817 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF840CA BHF840SA 26,737 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF840CPA BHF840SA 28,210 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF890CPA BHF890SA 29,035 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1050CPA BHF1050SA 32,807 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1220CPA BHF1220SA 36,742 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1440CPA BHF1440SA 46,094 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1860CPB BHF1860SB 55,772 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with Standard Motors - 460/1/60 BHG450MA BHG450SA 13,449 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG550MA BHG550SA 15,748 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF400MA BHF400SA 12,632 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF480MA BHF480SA 15,419 Standard 574 Call Factory 1,026 Call Factory Call Factory Hot Gas Defrost s with Standard Motors - 460/3/60 BHG450DPA BHG450SA 14,189 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG550DPA BHG550SA 16,485 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG640DA BHG640SA 17,058 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG640DPA BHG640SA 18,208 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG740DA BHG740SA 20,340 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG740DPA BHG740SA 21,488 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG810DA BHG810SA 24,279 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG810DPA BHG810SA 25,755 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG950DA BHG950SA 27,067 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG950DPA BHG950SA 28,540 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG1020DPA BHG1020SA 29,035 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1200DPA BHG1200SA 33,462 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1390DPA BHG1390SA 36,742 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHG1650DPA BHG1650SA 45,108 Standard 1,025 Call Factory 1,500 Call Factory Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 83

89 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow BHG2120DPB BHG2120SB 56,753 Standard 1,475 Call Factory 1,500 Call Factory Call Factory BHF400DPA BHF400SA 13,368 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF480DPA BHF480SA 16,161 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF560DA BHF560SA 16,896 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF560DPA BHF560SA 18,043 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF650DA BHF650SA 18,861 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF650DPA BHF650SA 20,011 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF710DA BHF710SA 20,340 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF710DPA BHF710SA 21,817 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF840DA BHF840SA 26,737 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF840DPA BHF840SA 28,210 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF890DPA BHF890SA 29,035 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1050DPA BHF1050SA 32,807 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1220DPA BHF1220SA 36,742 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1440DPA BHF1440SA 46,094 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1860DPB BHF1860SB 55,772 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with Standard Motors - 575/3/60 BHG450EPA BHG450SA 14,473 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG550EPA BHG550SA 16,816 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG640EPA BHG640SA 18,573 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG740EPA BHG740SA 21,920 Standard 574 Call Factory 1,026 Call Factory Call Factory BHG810EPA BHG810SA 26,270 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG950EPA BHG950SA 29,122 Standard 574 Call Factory 1,217 Call Factory Call Factory BHG1020EPA BHG1020SA 29,578 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1200EPA BHG1200SA 34,131 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHG1390EPA BHG1390SA 37,478 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHG1650EPA BHG1650SA 46,013 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHG2120EPB BHG2120SB 57,888 Standard 1,475 Call Factory 1,500 Call Factory Call Factory BHF400EPA BHF400SA 13,636 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF480EPA BHF480SA 16,483 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF560EPA BHF560SA 18,405 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF650EPA BHF650SA 20,411 Standard 574 Call Factory 1,026 Call Factory Call Factory BHF710EPA BHF710SA 22,253 Standard 574 Call Factory 1,217 Call Factory Call Factory BHF840EPA BHF840SA 28,777 Standard 574 Call Factory 1,217 Call Factory Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 84 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

90 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow BHF890EPA BHF890SA 29,613 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1050EPA BHF1050SA 33,462 Standard 1,025 Call Factory 1,217 Call Factory Call Factory BHF1220EPA BHF1220SA 37,478 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1440EPA BHF1440SA 47,016 Standard 1,025 Call Factory 1,500 Call Factory Call Factory BHF1860EPB BHF1860SB 56,885 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with High CFM Motors /3/60 - BHG450SA 16,321 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG550SA 18,619 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG640SA 21,363 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG740SA 24,645 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG810SA 30,019 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG950SA 32,807 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG1020SA 33,061 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1200SA 37,488 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1390SA 40,768 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG1650SA 49,134 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG2120SB 62,121 Standard 1,475 Call Factory 1,500 Call Factory Call Factory - BHF400SA 15,503 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF480SA 18,290 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF560SA 21,201 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF650SA 23,166 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF710SA 26,080 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF840SA 32,477 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF890SA 33,061 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1050SA 36,833 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1220SA 40,768 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1440SA 50,120 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1860SB 61,140 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Hot Gas Defrost s with High CFM Motors - 460/3/60 - BHG450SA 16,321 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG550SA 18,619 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG640SA 21,363 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG740SA 24,645 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHG810SA 30,019 Standard 574 Call Factory 1,217 Call Factory Call Factory Section 1 Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 85

91 Refrigerated Warehouse Unit Coolers Large Unit Coolers When Do You Choose a Configurable? Hot Gas Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Factory-Installed Options Adders Drain Pan Options Mechanical Options Coil Options Electric Hot Gas Loop Double Wall Insulated TXV ElectroFin Coil Bronz-Glow - BHG950SA 32,807 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHG1020SA 33,061 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1200SA 37,488 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHG1390SA 40,768 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG1650SA 49,134 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHG2120SB 62,121 Standard 1,475 Call Factory 1,500 Call Factory Call Factory - BHF400SA 15,503 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF480SA 18,290 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF560SA 21,201 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF650SA 23,166 Standard 574 Call Factory 1,026 Call Factory Call Factory - BHF710SA 26,080 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF840SA 32,477 Standard 574 Call Factory 1,217 Call Factory Call Factory - BHF890SA 33,061 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1050SA 36,833 Standard 1,025 Call Factory 1,217 Call Factory Call Factory - BHF1220SA 40,768 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1440SA 50,120 Standard 1,025 Call Factory 1,500 Call Factory Call Factory - BHF1860SB 61,140 Standard 1,475 Call Factory 1,500 Call Factory Call Factory Regulation Requires VFD Approved Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet must be variable speed and controlled in response to space conditions. Single phase evaporator fan motors less than 1 HP and less than 460V must be variable speed EC motors. Exception: Evaporators served by a single compressor without unloading capability. Notes: Adjustable Defrost Term/Fan Delay standard. Customer to supply VFD to control VFD approved motors. TXV = Expansion Valve 3 Phase Low temp motors and Stainless Steel Cabinet & Pan, Drain Pan Baffles, Electric Re-Heat Option, Dual Circuited Coils, and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 86 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

92 Refrigerated Warehouse Unit Coolers Large Unit Coolers Need a Hot Gas Reverse Cycle Kit? Hot Gas Reverse Cycle Kits Need help? Please contact your local Sales Representative or Account Engineer for assistance. Kits for s with Standard Electric Pan Hot Gas s Used On BHG BHF Factory-Installed Option Code Adder Shipped-Loose Part Number RCK.EP-1 3, RCK.EP-2 3, , RCK.EP-3 3, , RCK.EP-4 4, , RCK.EP-5 4, , RCK.EP-6 4, ,612 Section 1 Notes: Factory-installed kits include expansion valve and TXV bypass check valve assembly. Specify valve model style, refrigerant, and SST on order. Shipped-loose kits include one check valve and piping for TXV bypass around expansion valve. Kit does not include expansion valve. Kits for s with Optional Hot Gas Pan Hot Gas s Used On BHG BHF Factory-Installed Option Code Adder Shipped-Loose Part Number RCK.HGP-1 4, , RCK.HGP-2 5, , RCK.HGP-3 5, , RCK.HGP-4 6, , RCK.HGP-5 8, , RCK.HGP-6 8, , RCK.HGP-7 8, ,100 Notes: Factory installed kits included expansion valve, TXV Bypass check valve assembly, suction check valve assembly, and drain pan check valve assembly. Kit does not include hot gas pan price. Specify valve model style, refrigerant, and SST on order. Shipped-loose kits include one check valve and piping for TXV bypass around expansion valve, one check valve and piping for drain pan assembly and one check valve and piping for suction assembly. Kit does not include Hot gas pan pricing. Kit does not include expansion valve. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 87

93 Refrigerated Warehouse Unit Coolers Large Unit Coolers Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something or need help selecting the appropriate accessory for your unit? Please contact your local Sales Representative or Account Engineer for assistance. Section 1 Part Number Room Thermostats Description Room Thermostat Electronic Room Thermostat Extended Throw Collar for Air Throw (24" fan) Collar for Air Throw (30" fan) 672 Defrost Controls Notes Must be used with wire fan guards. Must order 1 per fan. Must be used with wire fan guards. Must order 1 per fan Electric Defrost Timer (60 Hz) R 30-Amp Contactor 365 Use as fan or heater contactor 5738-N 50-Amp Contactor Obsolete Use Interlink part Check Valves 5731F 1 5/8" Suction Line Check Valve /8" Suction Line Check Valve 1, /8" Suction Line Check Valve 1,959 - Drain Line Heaters 5508Q 6 ft. Drain Line heater ( V, 42 Watts) P 12 ft. Drain Line heater ( V, 84 Watts) P 18 ft. Drain Line heater ( V, 126 Watts) P 36 ft. Drain Line heater ( V, 252 Watts) P 60 ft. Drain Line heater ( V, 420 Watts) Heat Exchangers Heat Exchanger used on Air Defrost s, Electric & Hot Gas Defrost s (6 FPI), and Electric & Hot Gas Defrost s (4.5 FPI) Heat Exchanger used on Air Defrost s Heat Exchanger used on Air Defrost s, 640 Electric & Hot Gas Defrost s (6 FPI), and Electric & Hot Gas Defrost s (4.5 FPI) Heat Exchanger used on Electric & Hot Gas Defrost s (6 FPI), and Electric & Hot Gas Defrost s (4.5 FPI) 571 1,202 1, Heat Exchanger used on Air Defrost s 1, Heat Exchanger used on Air Defrost s, Electric & Hot Gas Defrost s (6 FPI), and Electric & Hot Gas Defrost s (4.5 FPI) 2,045 7/8" Liquid Connection OD, 1 5/8" Suction Connecction OD, 16" Length, 4lbs Approx. Ship Wt. 7/8" Liquid Connection OD, 2 1/8" Suction Connecction OD, 17" Length, 6lbs Approx. Ship Wt. 7/8" Liquid Connection OD, 2 1/8" Suction Connecction OD, 25" Length, 8lbs Approx. Ship Wt. 1 1/8" Liquid Connection OD, 2 1/8" Suction Connecction OD, 27" Length, 9lbs Approx. Ship Wt. 1 1/8" Liquid Connection OD, 2 5/8" Suction Connecction OD, 28" Length, 10lbs Approx. Ship Wt. 1 3/8" Liquid Connection OD, 2 5/8" Suction Connecction OD, 32" Length, 10lbs Approx. Ship Wt. 88 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

94 Refrigerated Warehouse Unit Coolers Large Unit Coolers Shipped-Loose Accessories Expansion Valves (TXV) When placing order, please specify refrigerant type, saturated suction temperature (SST), liquid temperature, and room temperature. Part Number Capacity Range (BTUH) TXV ,000 BTUH to 36,000 BTUH TXV ,000 BTUH to 60,000 BTUH TXV ,000 BTUH to 120,000 BTUH TXV ,000 BTUH to 360,000 BTUH TXV540 1, ,000 BTUH to 540,000 BTUH Section 1 Liquid-line Solenoid Valves (LLSV) Part Number Size Capacity Range (R-404A) Medium Temperature Application (BTUH) Low Temperature Application (BTUH) 5766Y 349 1/2 51,000 BTUH to 72,000 BTUH 44,000 BTUH to 62,000 BTUH 5768Y 463 5/8 72,000 BTUH to 144,000 BTUH 62,000 BTUH to 120,000 BTUH 5804E 573 7/8 144,000 BTUH to 216,000 BTUH 120,000 BTUH to 185,000 BTUH 5803E /8 216,000 BTUH to 380,000 BTUH 185,000 BTUH to 315,000 BTUH /8 24,000 BTUH to 44,000 BTUH 21,000 BTUH to 38,000 BTUH /2 36,000 BTUH to 51,000 BTUH 31,000 BTUH to 44,000 BTUH 5825N 1, /8 380,000 BTUH to 652,000 BTUH 315,000 BTUH to 540,000 BTUH Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 89

95 Glycol Unit Coolers Low Profile Overview Section 1 Product Description Low profile glycol unit coolers, are available in air, electric, or warm fluid defrost. These units are designed to offer an environmentally-friendly product that provides maximum capacity while occupying a minimum amount of space inside a walk-in cooler or freezer. These units are ideal for many applications including restaurants and convenience stores. The use of alternative refrigerants makes this product qualified to be included in the E Solutions product portfolio. Additional savings can be seen by opting for EC motors or the Beacon II Refrigeration System. Standard Features Ease of Installation & Service Cabinet design features front access panels on each side for easy access to electrical and refrigeration components All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Pre-drilled holes on the back of the unit for room thermostat Coil heater slots have been enlarged for easier installation and replacement On 4-6 fan models, drain pan has a lanyard for easy and safe access Motors plug into wiring harness for easier servicing Reliable & Durable Sweat connections to reduce potential for leaks Molded fan guard design made of strong plastic material Heavy gauge grained aluminum cabinet cleans easily and looks attractive Performance Internal panels are isolated for quiet operation Internally enhanced tubing and fin design for higher efficiency Reduced heater wattages Adjustable defrost termination for warm fluid defrost models Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in end compartments Versatile Large diameter drain hole (3/4" ID) is located on the back of the unit Minimal height of the low profile series makes it ideal for low ceiling coolers Certifications Nomenclature ADT G 0400 A K Series Refrigeratnt Capacity Electrical Code Vintage ADT = Low Profile, Air Defrost LET = Low Profile, Electric Defrost HGT = Low Profile, Warm Fluid Defrost G = Glycol BTUH/ITD AE = 115/1/60 (EC) BE = /1/60 (EC) CE = /3/60 (EC) M = 460/1/60 S = Configurable 90 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

96 Glycol Unit Coolers Low Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Air Defrost s with EC Motors - 115/1/60 No. of Fans Factory - Installed Options Adders Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - ADTG0400SK 2, Call Factory 1,062 Call Factory - ADTG0475SK 2, Call Factory 1,062 Call Factory - ADTG0525SK 3, Call Factory 1,062 Call Factory - ADTG0725SK 4, ,038 Call Factory 1,083 Call Factory - ADTG0900SK 5,857 4 Call Factory Call Factory 1,106 Call Factory - ADTG1000SK 7,310 5 Call Factory Call Factory 1,132 Call Factory - ADTG1300SK 7,587 5 Call Factory Call Factory 1,132 Call Factory - ADTG1475SK 8,430 6 Call Factory Call Factory 1,154 Call Factory Air Defrost s with EC Motors /1/60 - ADTG0400SK 2, Call Factory 1,062 Call Factory - ADTG0475SK 3, Call Factory 1,062 Call Factory - ADTG0525SK 3, Call Factory 1,062 Call Factory - ADTG0725SK 4, ,038 Call Factory 1,083 Call Factory - ADTG0900SK 6,559 4 Call Factory Call Factory 1,106 Call Factory - ADTG1000SK 8,163 5 Call Factory Call Factory 1,132 Call Factory - ADTG1300SK 8,440 5 Call Factory Call Factory 1,132 Call Factory - ADTG1475SK 9,396 6 Call Factory Call Factory 1,154 Call Factory Air Defrost s with PSC Motors - 460/1/60 - ADTG0400SK 2, Call Factory 1,062 Call Factory - ADTG0475SK 2, Call Factory 1,062 Call Factory - ADTG0525SK 3, Call Factory 1,062 Call Factory - ADTG0725SK 4, ,038 Call Factory 1,083 Call Factory - ADTG0900SK 6,098 4 Call Factory Call Factory 1,106 Call Factory - ADTG1000SK 7,529 5 Call Factory Call Factory 1,132 Call Factory - ADTG1300SK 7,806 5 Call Factory Call Factory 1,132 Call Factory - ADTG1475SK 8,589 6 Call Factory Call Factory 1,154 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. 91

97 Glycol Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Electric Defrost s with EC Motors /1/60 Factory-Installed Options Adders Coil Options Bronz-Glow - LETG0400SK 3,968 2 Call Factory - LETG0475SK 4,025 2 Call Factory - LETG0525SK 4,201 2 Call Factory - LETG0725SK 5,542 3 Call Factory - LETG0900SK 7,199 4 Call Factory - LETG1000SK 8,930 5 Call Factory - LETG1300SK 9,208 5 Call Factory - LETG1475SK 10,163 6 Call Factory Electric Defrost s with EC Motors /3/60 - LETG0400SK 4,238 2 Call Factory - LETG0475SK 4,297 2 Call Factory - LETG0525SK 4,471 2 Call Factory - LETG0725SK 5,812 3 Call Factory - LETG0900SK 7,467 4 Call Factory - LETG1000SK 9,199 5 Call Factory - LETG1300SK 9,478 5 Call Factory - LETG1475SK 10,433 6 Call Factory Electric Defrost s with PSC Motors - 460/1/60 - LETG0400SK 4,150 2 Call Factory - LETG0475SK 4,208 2 Call Factory - LETG0525SK 4,383 2 Call Factory - LETG0725SK 5,550 3 Call Factory - LETG0900SK 7,035 4 Call Factory - LETG1000SK 8,594 5 Call Factory - LETG1300SK 8,871 5 Call Factory - LETG1475SK 9,654 6 Call Factory 92 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent & drain valves, heater limit thermostats and adjustable defrost termination fan delay. Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

98 Glycol Unit Coolers Low Profile When Do You Choose a Configurable? Warm Fluid Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable No. of Fans Warm Fluid Defrost s with EC Motors - 115/1/60 Factory-Installed Options Adders ElectroFin Coil Coil Options Bronz-Glow - HGTG0475SK 3,977 2 Call Factory Call Factory - HGTG0525SK 4,467 2 Call Factory Call Factory - HGTG0725SK 6,083 3 Call Factory Call Factory - HGTG0900SK 6,758 4 Call Factory Call Factory - HGTG1300SK 8,138 5 Call Factory Call Factory - HGTG1475SK 9,644 6 Call Factory Call Factory Warm Fluid Defrost s with EC Motors /1/60 - HGTG0475SK 4,393 2 Call Factory Call Factory - HGTG0525SK 4,883 2 Call Factory Call Factory - HGTG0725SK 6,499 3 Call Factory Call Factory - HGTG0900SK 7,578 4 Call Factory Call Factory - HGTG1300SK 9,116 5 Call Factory Call Factory - HGTG1475SK 11,017 6 Call Factory Call Factory Warm Fluid Defrost s with PSC Motors - 460/1/60 - HGTG0475SK 4,275 2 Call Factory Call Factory - HGTG0525SK 4,765 2 Call Factory Call Factory - HGTG0725SK 6,210 3 Call Factory Call Factory - HGTG0900SK 7,116 4 Call Factory Call Factory - HGTG1300SK 8,482 5 Call Factory Call Factory - HGTG1475SK 10,210 6 Call Factory Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. All Warm Fluid Defrost s have Fan Defrost Control included Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. 93

99 Glycol Unit Coolers Low Velocity Center Mount Overview Section 1 Product Description Low velocity glycol center mount units, are available in air, electric, or warm fluid defrost. These units are designed to offer an environmentally friendly product that is ideal for floral storage,fresh fruit and vegetables, dough retarding, fresh meat storage and preparations, and many other applications. The low air flow and quiet fans are classically suited for work room applications. The generous coil surface combined with close T.D. system balance provides high humidity characteristics to minimize product shrinkage and drying. The use of alternative refrigerants makes this product qualified to be included in the E Solutions product portfolio. Additional savings can be seen by opting for EC motors or the Beacon II Refrigeration System. Standard Features Ease of Installation & Service All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Cabinet design features access panels on each end for easy access to electrical and refrigeration components Fan panel is lightweight and can easily be lowered for easy servicing and installation Reliable & Durable Heavy gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with PVC coating for durability Sweat connections to reduce potential for leaks Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Motor rail is design for maximum strength and durability Performance Internally enhanced tubing and fin design for higher efficiency All warm-fluid defrost models have heater/fan control factory set and wired All electric defrost models include defrost termination thermostats Motors are life lubricated and thermal overload protected Versatile Low height makes it ideal for low ceiling coolers - larger models are only 15 inches tall, allowing for maximum headroom and more product storage Unit designed to be mounted flush against the ceiling or suspended on rods Certifications Nomenclature WKA G 0400 A C Series Refrigeratnt Capacity Electrical Code Vintage WKA = Low Velocity G = Glycol BTUH/ITD AE = 115/1/60 (EC) Center Mount, Air BE = /1/60 (EC) defrost M = 460/1/60 WKG = Low Velocity S = Configurable Center Mount, Warm Fluid defrost WKE = Low Velocity Center Mount, Electric Defrost 94 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

100 Glycol Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Air Defrost s with EC Motors - 115/1/60 No. of Fans Factory-Installed Options Adders ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - WKAG0330SC 3,701 1 Call Factory 1,040 Call Factory - WKAG0425SC 4,427 1 Call Factory 1,040 Call Factory - WKAG0700SC 5,413 2 Call Factory 1,533 Call Factory - WKAG0875SC 6,789 2 Call Factory 1,533 Call Factory - WKAG0975SC 7,090 2 Call Factory 1,533 Call Factory - WKAG1025SC 8,877 3 Call Factory 2,090 Call Factory - WKAG1225SC 9,265 3 Call Factory 2,090 Call Factory - WKAG1450SC 10,489 4 Call Factory 2,435 Call Factory - WKAG1650SC 13,748 5 Call Factory 3,304 Call Factory Air Defrost s with EC Motors /1/60 - WKAG0330SC 4,088 1 Call Factory 1,040 Call Factory - WKAG0425SC 4,887 1 Call Factory 1,040 Call Factory - WKAG0700SC 5,943 2 Call Factory 1,533 Call Factory - WKAG0875SC 7,433 2 Call Factory 1,533 Call Factory - WKAG0975SC 7,813 2 Call Factory 1,533 Call Factory - WKAG1025SC 9,736 3 Call Factory 2,090 Call Factory - WKAG1225SC 10,125 3 Call Factory 2,090 Call Factory - WKAG1450SC 11,542 4 Call Factory 2,435 Call Factory - WKAG1650SC 15,105 5 Call Factory 3,304 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. Wire fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. 95

101 Glycol Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Electric Defrost s with EC Motors /1/60 Factory-Installed Options Adders Coil Options Bronz-Glow - WKEG0330SC 5,043 1 Call Factory - WKEG0425SC 5,803 1 Call Factory - WKEG0700SC 7,062 2 Call Factory - WKEG0875SC 8,493 2 Call Factory - WKEG0975SC 8,836 2 Call Factory - WKEG1025SC 10,928 3 Call Factory - WKEG1225SC 11,317 3 Call Factory - WKEG1450SC 12,875 4 Call Factory - WKEG1650SC 16,523 5 Call Factory 96 Federal Regulation Requires EC Motors Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent & drain valves, heater limit thermostats and adjustable defrost termination fan delay. Wire fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

102 Glycol Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Warm Fluid Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable No. of Fans Warm Fluid Defrost s with EC Motors - 115/1/60 Factory-Installed Options Adders ElectroFin Coil Coil Options Bronz-Glow - WKGG0700SC 5,714 2 Call Factory Call Factory - WKGG0875SC 7,205 2 Call Factory Call Factory - WKGG0975SC 7,528 2 Call Factory Call Factory - WKGG1025SC 9,607 3 Call Factory Call Factory - WKGG1225SC 10,031 3 Call Factory Call Factory - WKGG1450SC 11,470 4 Call Factory Call Factory - WKGG1650SC 15,183 5 Call Factory Call Factory Warm Fluid Defrost s with EC Motors /1/60 - WKGG0700SC 6,288 2 Call Factory Call Factory - WKGG0875SC 7,848 2 Call Factory Call Factory - WKGG0975SC 8,172 2 Call Factory Call Factory - WKGG1025SC 10,608 3 Call Factory Call Factory - WKGG1225SC 11,033 3 Call Factory Call Factory - WKGG1450SC 12,565 4 Call Factory Call Factory - WKGG1650SC 16,758 5 Call Factory Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. All Warm Fluid Defrost s have Fan Defrost Control included. Wire fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. 97

103 Glycol Unit Coolers Center Mount Overview Section 1 Product Description Center mount glycol unit coolers are available in air defrost. They are ideal for tight storage situations because they are ceiling mount and have a height of only 8-5/8 allowing for maximum headroom in a cooler or freezer. The center mount design allows for product to be stacked all around while air flow distributes evenly throughout the box. The use of alternative refrigerants and energy efficient EC motors makes this product qualified to be included in the E Solutions product portfolio. Standard Features Ease of Installation & Service Panels on ends quickly remove for complete access to refrigerant components and electrical terminal block during installation and servicing Tapered mounting provides proper slope for condensate drainage to one end of the unit Reliable & Durable Heavy-gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with PVC coating for durability Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Performance Quick disconnect, waterproof plug and receptacle for each motor in all models High-efficiency aluminum fins with full collars cover mechanically expanded copper tubes Highest quality tubular heaters provide fast and economical defrost Motors are life lubricated and thermal overload protected Air moves across the ceiling in both directions providing even air distribution throughout the cooler Versatile Compact, ceiling mount and center mount design allows for shelving and storage of product around all walls Certifications Nomenclature 98 SMA G 475 A E Series Type Capacity Electrical Code Vintage SMA = Center Mount, Air Defrost G = Glycol BTUH/TD AE = 115/1/60 (EC) BE = /1/60 (EC) S = Configurable E = EC Motor s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

104 Glycol Unit Coolers Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable No. of Fans Air Defrost s with EC Motors - 115/1/60 Factory - Installed Options Adders Kote ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - SMAG0475SE 3, Call Factory 834 Call Factory - SMAG0525SE 3, Call Factory 834 Call Factory - SMAG0550SE 4, Call Factory 834 Call Factory - SMAG0575SE 4, Call Factory 834 Call Factory - SMAG0600SE 4,707 3 Call Factory Call Factory 1,184 Call Factory - SMAG0625SE 5,224 3 Call Factory Call Factory 1,184 Call Factory - SMAG0775SE 5,706 3 Call Factory Call Factory 1,184 Call Factory - SMAG0800SE 6,436 4 Call Factory Call Factory 1,473 Call Factory - SMAG0925SE 6,664 4 Call Factory Call Factory 1,473 Call Factory - SMAG0975SE 7,022 4 Call Factory Call Factory 1,473 Call Factory - SMAG1050SE 8,692 5 Call Factory Call Factory 1,897 Call Factory Air Defrost s with EC Motors /1/60 - SMAG0475SE 3, Call Factory 834 Call Factory - SMAG0525SE 3, Call Factory 834 Call Factory - SMAG0550SE 4, Call Factory 834 Call Factory - SMAG0575SE 4, Call Factory 834 Call Factory - SMAG0600SE 4,953 3 Call Factory Call Factory 1,184 Call Factory - SMAG0625SE 5,460 3 Call Factory Call Factory 1,184 Call Factory - SMAG0775SE 5,943 3 Call Factory Call Factory 1,184 Call Factory - SMAG0800SE 6,711 4 Call Factory Call Factory 1,473 Call Factory - SMAG0925SE 6,937 4 Call Factory Call Factory 1,473 Call Factory - SMAG0975SE 7,295 4 Call Factory Call Factory 1,473 Call Factory - SMAG1050SE 9,001 5 Call Factory Call Factory 1,897 Call Factory Section 1 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 99

105 Glycol Unit Coolers Medium Profile Overview Section 1 Product Description Medium profile glycol unit coolers are available in air defrost models. These units are designed to offer an environmentally-friendly product and are ideal for numerous commercial and industrial applications. With a modular design that is only 25 inches high, these units provide superior quality and a long, dependable life to many different applications. The use of alternative refrigerants makes this product qualified to be included in the E Solutions product portfolio. Additional savings can be seen by opting for EC motors or the Beacon II Refrigeration System. Standard Features Ease of Installation & Service All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Front hinged drain pan for easy access Motors plug into wiring harness for easier servicing Reliable & Durable Heavy gauge textured aluminum cabinet Sweat connections to reduce potential for leaks Patented Thermo-Flex coil design allows the coil to flex during periods of defrost resulting in expansion of the coil surface comes with a 5-year warranty Heavy plastic molded fan guards for extended air flow Thermally protected, lifetime-lubricated single phase PSC motors Performance Internal panels are isolated for quiet operation PSC motors Versatile Large diameter drain fitting (3/4 ID) Different motor and voltage options available Certifications Nomenclature 100 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

106 Glycol Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable Air Defrost s with EC Motors - 115/1/60 No. of Fans Kote Factory-Installed Options Adders ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMAG0900SA 5, ,270 Call Factory 1,148 Call Factory - BMAG1100SA 7,550 2 Call Factory Call Factory 1,211 Call Factory - BMAG1275SA 9,328 2 Call Factory Call Factory 1,211 Call Factory - BMAG1600SA 9,732 2 Call Factory Call Factory 1,211 Call Factory - BMAG1700SA 11,897 3 Call Factory Call Factory 1,276 Call Factory - BMAG1900SA 12,397 3 Call Factory Call Factory 1,276 Call Factory - BMAG2175SA 14,292 3 Call Factory Call Factory 1,276 Call Factory - BMAG2400SA 16,859 4 Call Factory Call Factory 1,333 Call Factory - BMAG2425SA 17,283 4 Call Factory Call Factory 1,333 Call Factory - BMAG2850SA 18,021 4 Call Factory Call Factory 1,333 Call Factory Air Defrost s with EC Motors /1/60 - BMAG0900SA 5, ,270 Call Factory 1,148 Call Factory - BMAG1100SA 7,807 2 Call Factory Call Factory 1,211 Call Factory - BMAG1275SA 9,584 2 Call Factory Call Factory 1,211 Call Factory - BMAG1600SA 9,990 2 Call Factory Call Factory 1,211 Call Factory - BMAG1700SA 12,291 3 Call Factory Call Factory 1,276 Call Factory - BMAG1900SA 12,801 3 Call Factory Call Factory 1,276 Call Factory - BMAG2175SA 14,694 3 Call Factory Call Factory 1,276 Call Factory - BMAG2400SA 17,380 4 Call Factory Call Factory 1,333 Call Factory - BMAG2425SA 17,809 4 Call Factory Call Factory 1,333 Call Factory - BMAG2850SA 18,548 4 Call Factory Call Factory 1,333 Call Factory Air Defrost s with PSC Motors /1/60 - BMAG0900SA 4, ,270 Call Factory 1,148 Call Factory - BMAG1100SA 6,477 2 Call Factory Call Factory 1,211 Call Factory - BMAG1275SA 8,254 2 Call Factory Call Factory 1,211 Call Factory - BMAG1600SA 8,660 2 Call Factory Call Factory 1,211 Call Factory - BMAG1700SA 10,296 3 Call Factory Call Factory 1,276 Call Factory - BMAG1900SA 10,806 3 Call Factory Call Factory 1,276 Call Factory - BMAG2175SA 12,699 3 Call Factory Call Factory 1,276 Call Factory - BMAG2400SA 14,720 4 Call Factory Call Factory 1,333 Call Factory - BMAG2425SA 15,149 4 Call Factory Call Factory 1,333 Call Factory - BMAG2850SA 15,888 4 Call Factory Call Factory 1,333 Call Factory - BMAG3100SA 17,330 5 Call Factory Call Factory 1,368 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. 101

107 Glycol Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable Air Defrost s with PSC Motors - 460/1/60 No. of Fans Kote Factory-Installed Options Adders ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMAG0900SA 5, ,270 Call Factory 1,148 Call Factory - BMAG1100SA 6,816 2 Call Factory Call Factory 1,211 Call Factory - BMAG1275SA 8,591 2 Call Factory Call Factory 1,211 Call Factory - BMAG1600SA 8,997 2 Call Factory Call Factory 1,211 Call Factory - BMAG1700SA 10,793 3 Call Factory Call Factory 1,276 Call Factory - BMAG1900SA 11,299 3 Call Factory Call Factory 1,276 Call Factory - BMAG2175SA 13,191 3 Call Factory Call Factory 1,276 Call Factory - BMAG2400SA 15,388 4 Call Factory Call Factory 1,333 Call Factory - BMAG2425SA 15,813 4 Call Factory Call Factory 1,333 Call Factory - BMAG2850SA 16,553 4 Call Factory Call Factory 1,333 Call Factory - BMAG3100SA 18,292 5 Call Factory Call Factory 1,368 Call Factory Air Defrost s with PSC Motors - 575/1/60 - BMAG0900SA 5, ,270 Call Factory 1,148 Call Factory - BMAG1100SA 6,951 2 Call Factory Call Factory 1,211 Call Factory - BMAG1275SA 8,669 2 Call Factory Call Factory 1,211 Call Factory - BMAG1600SA 9,073 2 Call Factory Call Factory 1,211 Call Factory - BMAG1700SA 11,013 3 Call Factory Call Factory 1,276 Call Factory - BMAG1900SA 11,549 3 Call Factory Call Factory 1,276 Call Factory - BMAG2175SA 13,444 3 Call Factory Call Factory 1,276 Call Factory - BMAG2400SA 15,682 4 Call Factory Call Factory 1,333 Call Factory - BMAG2425SA 16,123 4 Call Factory Call Factory 1,333 Call Factory - BMAG2850SA 16,862 4 Call Factory Call Factory 1,333 Call Factory - BMAG3100SA 18,643 5 Call Factory Call Factory 1,368 Call Factory 102 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Base price includes vent and drain valves. Plastic fan guards are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. See page 103 for available shipped-loose Balance Valve and Shut-off Valve options. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

108 Glycol Unit Coolers Shipped-Loose Accessories Balance & Shut-Off Valves Balance and shut-off valves must be selected by GPM rating and not valve size. In order to calculate the proper GPM rating for your glycol unit cooler, please contact your local Sales Representative or Account Engineer for assistance. GPM Balance Valve Size Part Number Balance Valve Shut-off Valve /2 (5/8" OD) /4 (7/8" OD) (1-1/8" OD) /4 (1-3/8" OD) /2 (1-5/8" OD) Notes: Balance Valve and Shut-off Valve are sold together. Secondary loop selection program must be used to calculate the required GPM rating for the glycol unit cooler before selecting the appropriate balance and shut-off valves Section 1 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 103

109 CO₂ Unit Coolers Low Profile Overview Standard Features Section 1 Product Description Low profile CO2 unit coolers designed for use with carbon dioxide systems are available in air or electric defrost for medium and low temperature overfeed/ recirculation or low temperature DX applications. These units are designed to offer an environmentally-friendly product that provides maximum capacity while occupying a minimum amount of space inside a walkin cooler or freezer.the use of alternative refrigerants and energy efficient EC motors makes this product qualified to be included in the E Solutions product portfolio. Ease of Installation & Service Cabinet design features front access panels on each side for easy access to electrical and refrigeration components All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Coil heater slots have been enlarged for easier installation and replacement On 4-6 fan models, drain pan has a lanyard for easy and safe access Motors plug into wiring harness for easier servicing Reliable & Durable Sweat connections to reduce potential for leaks Molded fan guard design made of strong plastic material Heavy gauge grained aluminum cabinet cleans easily and looks attractive Performance Internal panels are isolated for quiet operation Internally enhanced tubing and fin design for higher efficiency Defrost termination control supplied for electric defrost Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in end compartments EC motors Versatile Large diameter drain hole (3/4" ID) is located on the back of the unit Minimal height of the low profile series makes it ideal for low ceiling coolers Certifications Nomenclature 104 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

110 CO₂ Unit Coolers Low Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable No. of Fans Defrost Type Factory-Installed Options Adders Kote Medium Temperature Overfeed / Recirculation s with EC Motors-115/1/60 ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - ADTR065SK 2,069 1 Air Defrost 456 Call Factory 1,040 Call Factory - ADTR070SK 2,619 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR090SK 2,971 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR104SK 3,147 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR130SK 3,557 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR156SK 4,527 3 Air Defrost 988 Call Factory 1,083 Call Factory - ADTR180SK 5,072 3 Air Defrost 988 Call Factory 1,083 Call Factory - ADTR208SK 4,970 4 Air Defrost Call Factory Call Factory 1,106 Call Factory - ADTR260SK 7,333 5 Air Defrost Call Factory Call Factory 1,132 Call Factory Medium Temperature Overfeed / Recirculation s with EC Motors /1/60 - ADTR065SK 2,204 1 Air Defrost 456 Call Factory 1,040 Call Factory - ADTR070SK 2,772 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR090SK 3,006 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR104SK 3,188 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR130SK 3,595 2 Air Defrost 676 Call Factory 1,062 Call Factory - ADTR156SK 4,584 3 Air Defrost 988 Call Factory 1,083 Call Factory - ADTR180SK 5,129 3 Air Defrost 988 Call Factory 1,083 Call Factory - ADTR208SK 6,248 4 Air Defrost Call Factory Call Factory 1,106 Call Factory - ADTR260SK 7,776 5 Air Defrost Call Factory Call Factory 1,132 Call Factory Section 1 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 105

111 CO₂ Unit Coolers Low Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Defrost Type Factory-Installed Options Adders Coil Options Bronz-Glow Medium Temperature Overfeed / Recirculation s with EC Motors /1/60 - LETR065SK 3,721 2 Electric Defrost Call Factory - LETR090SK 4,113 2 Electric Defrost Call Factory - LETR120SK 5,318 3 Electric Defrost Call Factory - LETR140SK 6,038 3 Electric Defrost Call Factory - LETR160SK 7,083 4 Electric Defrost Call Factory - LETR200SK 8,993 5 Electric Defrost Call Factory - LETR240SK 10,271 6 Electric Defrost Call Factory - LETR280SK 11,525 6 Electric Defrost Call Factory Low Temperature DX s with EC Motors /1/60 - LETC065SK 3,721 2 Electric Defrost Call Factory - LETC090SK 4,113 2 Electric Defrost Call Factory - LETC120SK 5,318 3 Electric Defrost Call Factory - LETC140SK 6,038 3 Electric Defrost Call Factory - LETC160SK 7,083 4 Electric Defrost Call Factory - LETC200SK 8,993 5 Electric Defrost Call Factory - LETC240SK 10,271 6 Electric Defrost Call Factory - LETC280SK 11,525 6 Electric Defrost Call Factory - LLEC080SK 4,330 2 Electric Defrost Call Factory - LLEC102SK 5,272 3 Electric Defrost Call Factory - LLEC136SK 6,970 4 Electric Defrost Call Factory - LLEC170SK 8,810 5 Electric Defrost Call Factory - LLEC235SK 11,333 6 Electric Defrost Call Factory 106 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

112 CO₂ Unit Coolers Low Velocity Center Mount Overview Product Description Low velocity CO2 center mount units designed for use with carbon dioxide systems are available in air or electric defrost. These units are designed to offer an environmentally friendly product that is ideal for floral storage, fresh fruit and vegetables, dough retarding, fresh meat storage and preparations, and many other applications. The low air flow and quiet fans are classically suited for work room applications. The use of alternative refrigerants and energy efficient EC motors makes this product qualified to be included in the E Solutions product portfolio. Certifications Standard Features Ease of Installation & Service All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Cabinet design features access panels on each end for easy access to electrical and refrigeration components Fan panel is lightweight and can easily be lowered for easy servicing and installation Reliable & Durable Textured aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with coating for durability Sweat connections to reduce potential for leaks Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Motor rail is design for maximum strength and durability Performance Internally enhanced tubing and fin design for higher efficiency Electric defrost models incorporate high quality tubular heaters and a standard fixed defrost termination thermostat Motors are life lubricated and thermal overload protected EC motors Versatile Low height makes it ideal for low ceiling coolers - larger models are only 15 inches tall, allowing for maximum headroom and more product storage Unit designed to be mounted flush against the ceiling or suspended on rods Section 1 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 107

113 CO₂ Unit Coolers Low Velocity Center Mount When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Defrost Type Factory-Installed Options Adders ElectroFin Coil Medium Temperature Overfeed / Recircution s with EC Motors - 115/1/60 Coil Options Guard Fin Protection Bronz-Glow - WKAR050SC 3,821 1 Air Defrost Call Factory 1,040 Call Factory - WKAR075SC 4,429 1 Air Defrost Call Factory 1,040 Call Factory - WKAR100SC 5,410 2 Air Defrost Call Factory 1,533 Call Factory - WKAR130SC 6,314 2 Air Defrost Call Factory 1,533 Call Factory - WKAR155SC 7,057 2 Air Defrost Call Factory 1,533 Call Factory - WKAR180SC 8,639 3 Air Defrost Call Factory 2,090 Call Factory - WKAR210SC 9,779 4 Air Defrost Call Factory 2,435 Call Factory - WKAR270SC 10,717 4 Air Defrost Call Factory 2,435 Call Factory - WKAR340SC 13,749 5 Air Defrost Call Factory 3,304 Call Factory Medium Temperature Overfeed / Recircution s with EC Motors /1/60 - WKAR050SC 4,021 1 Air Defrost Call Factory 1,040 Call Factory - WKAR075SC 4,668 1 Air Defrost Call Factory 1,040 Call Factory - WKAR100SC 5,694 2 Air Defrost Call Factory 1,533 Call Factory - WKAR130SC 6,655 2 Air Defrost Call Factory 1,533 Call Factory - WKAR155SC 7,438 2 Air Defrost Call Factory 1,533 Call Factory - WKAR180SC 9,089 3 Air Defrost Call Factory 2,090 Call Factory - WKAR210SC 10,279 4 Air Defrost Call Factory 2,435 Call Factory - WKAR270SC 11,267 4 Air Defrost Call Factory 2,435 Call Factory - WKAR340SC 14,459 5 Air Defrost Call Factory 3,304 Call Factory Low Velocity Center Mount Electric Defrost s & Options Standard Configurable No. of Fans Defrost Type Factory-Installed Options Adders Coil Options Bronz-Glow Medium Temperature Overfeed / Recirculation s with EC Motors /1/60 - WKER050SC 4,469 1 Electric Defrost Call Factory - WKER075SC 5,190 1 Electric Defrost Call Factory - WKER100SC 6,301 2 Electric Defrost Call Factory - WKER130SC 7,376 2 Electric Defrost Call Factory - WKER155SC 8,262 2 Electric Defrost Call Factory - WKER180SC 10,065 3 Electric Defrost Call Factory - WKER210SC 11,360 4 Electric Defrost Call Factory - WKER270SC 12,473 4 Electric Defrost Call Factory - WKER340SC 16,010 5 Electric Defrost Call Factory Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan is standard on electric defrost models. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 108 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

114 CO₂ Unit Coolers Center Mount Overview Product Description Center Mount CO2 unit coolers designed for use with carbon dioxide systems are available in electric defrost. They are ideal for tight storage situations because they are ceiling mount and have a height of only 8-5/8" allowing for maximum headroom in a cooler or freezer. The center mount design allows for product to be stacked all around while air flow distributes evenly throughout the box. The use of alternative refrigerants and energy efficient EC motors makes this product qualified to be included in the E Solutions product portfolio. Standard Features Ease of Installation & Service Panels on ends quickly remove for complete access to refrigerant components and electrical terminal block during installation and servicing Tapered mounting provides proper slope for condensate drainage to one end of the unit Reliable & Durable Heavy-gauge grained aluminum cabinet cleans easily and looks attractive Stainless steel screws prevent rust streaks Wire fan guards with coating for durability Coils are dehydrated and sealed at the factory Double drain pan eliminates drain pan sweating Performance Quick disconnect, waterproof plug and receptacle for each motor in all models High-efficiency aluminum fins with full collars cover mechanically expanded copper tubes Highest quality tubular heaters provide fast and economical defrost Standard adjustable defrost termination fan delay thermostat Motors are life lubricated and thermal overload protected Air moves across the ceiling in both directions providing even air distribution throughout the cooler EC motors Versatile Compact, ceiling mount and center mount design allows for shelving and storage of product around all walls Section 1 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 109

115 CO₂ Unit Coolers Center Mount When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Defrost Type Low Temperature DX s with EC Motors /1/60 Factory-Installed Options Adders Coil Options Bronz-Glow - SMEC090SE 5,902 3 Electric Defrost Call Factory - SMEC130SE 6,464 3 Electric Defrost Call Factory - SMEC174SE 8,376 4 Electric Defrost Call Factory 110 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan and Adjustable Defrost Term. / Fan Delay are standard. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

116 CO₂ Unit Coolers Medium Profile Overview Standard Features Product Description Medium profile CO2 unit coolers for use with carbon dioxide systems are available in air or electric defrost models. These units are designed to offer an environmentally friendly product and are ideal for numerous commercial and industrial applications. With a modular design that is only 25 inches high, these units provide superior quality and a long, dependable life to many different applications. The use of alternative refrigerants and energy efficient EC motors makes this product qualified to be included in the E Solutions product portfolio. Ease of Installation & Service All electrical components factory wired to terminal board and identified, making it easy to field wire the unit Schrader valve provided for suction pressure measurement Coil heater slots have been enlarged for easier installation and replacement Heaters are coil face mounted for easy access Front hinged drain pan for easy access Motors plug into wiring harness for easier servicing Reliable & Durable Heavy gauge textured aluminum cabinet Sweat connections to reduce potential for leaks Patented Thermo-Flex coil design allows the coil to flex during periods of defrost resulting in expansion of the coil surface comes with a 5-year warranty Plastic molded fan guards for extended air flow Reliable nickel steel alloy defrost heater elements Performance Internal panels are isolated for quiet operation Electric defrost models have fixed defrost termination / fan delay and heater limit thermostats EC motors Versatile Large diameter drain fitting (3/4 ID) Different motor and voltage options available Section 1 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 111

117 CO₂ Unit Coolers Medium Profile When Do You Choose a Configurable? Air Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Section 1 Standard Configurable No. of Fans Defrost Type Factory-Installed Options Adders Kote Medium Temperature Overfeed / Recirculation s with EC Motors - 115/1/60 ElectroFin Coil Coil Options Guard Fin Protection Bronz-Glow - BMAR130SA 4,534 1 Air Defrost 1,270 Call Factory 1,148 Call Factory - BMAR155SA 5,255 1 Air Defrost 1,270 Call Factory 1,148 Call Factory - BMAR245SA 7,790 2 Air Defrost Call Factory Call Factory 1,211 Call Factory - BMAR300SA 9,608 2 Air Defrost Call Factory Call Factory 1,211 Call Factory - BMAR365SA 12,147 3 Air Defrost Call Factory Call Factory 1,276 Call Factory - BMAR450SA 14,199 3 Air Defrost Call Factory Call Factory 1,276 Call Factory Medium Temperature Overfeed / Recirculation s with EC Motors /1/60 - BMAR130SA 4,607 1 Air Defrost 1,270 Call Factory 1,148 Call Factory - BMAR155SA 5,318 1 Air Defrost 1,270 Call Factory 1,148 Call Factory - BMAR245SA 7,921 2 Air Defrost Call Factory Call Factory 1,211 Call Factory - BMAR300SA 9,744 2 Air Defrost Call Factory Call Factory 1,211 Call Factory - BMAR365SA 12,357 3 Air Defrost Call Factory Call Factory 1,276 Call Factory - BMAR450SA 14,409 3 Air Defrost Call Factory Call Factory 1,276 Call Factory Medium Profile When Do You Choose a Configurable? Electric Defrost s & Options Choose when there is not a standard model listed or you want to add factory-installed options. When ordering a configurable model, remember to specify the voltage and fan motor type. Standard Configurable No. of Fans Low Temperature DX s with EC Motors /1/60 Defrost Type Factory-Installed Options Adders Coil Options Bronz-Glow - BMLC100SA 5,563 1 Electric Defrost Call Factory - BMLC165SA 8,068 2 Electric Defrost Call Factory - BMLC220SA 10,602 2 Electric Defrost Call Factory - BMLC250SA 11,852 3 Electric Defrost Call Factory - BMLC330SA 15,096 3 Electric Defrost Call Factory 112 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Notes: Electric Drain Pan and Adjustable Defrost Term. / Fan Delay are standard on electric defrost models. Stainless Steel Cabinet & Pan and Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

118 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Overview Product Description The 1/2 through 6 HP line of air-cooled condensing units with HyperCore microchannel coil technology is ideal for convenience store, restaurant and other commercial applications. Available with hermetic, Scroll, or semihermetic compressors and indoor or outdoor models, this line is a good fit for many applications. Opting for the Beacon II Refrigeration System with Smart Defrost, factory-installed Smart Defrost Kit (SDK), or Variable Speed EC (VSEC) motor with Orbus Controller increases energy efficiency and qualifies this product for the E Solutions product portfolio. Certifications Cabinet & Construction HyperCore microchannel coil technology standard on most models. Painted steel cabinets for superior strength and corrosion protection Heavy duty steel raised base with 1-1/2" legs Fan guards and wiring conduit on indoor models Serviceability Suction service valves for hermetic and scroll compressors located outside the cabinet for quick installations. Semi-hermetic compressor models have a suction valve on the compressor and an access fitting on the suction line entering the cabinet. Receiver with fusible plug, liquid shutoff valve and charging port is standard Large electrical panel for ease of access Prefabricated wiring harnesses for tight crimp connections and consistent labeling Unit stays on if the hood is removed for servicing Sight glass is easily viewable Quality All units are completely leak tested in a helium environment, bump tested and allowed to cycle off on the high and low pressure control. Each unit has a copy of the run data shipped inside the electrical panel Electrical circuits are completely checked for continuity Piping is laid out to minimize stress and vibration and is pre-bent to eliminate leaks Encapsulated, auto-reset, high and low pressure controls to eliminate leaks (standard on all high and medium temperature models, adjustable low pressure control standard on low temperature models) Components Fan Specifically matched with motor and coil to attain maximum air movement and cooling Motor Rated for 50 and 60 cycle application Standard PSC or optional Variable Speed EC (VSEC) with Orbus Controller Compressor Wide variety of compressors including: hermetic, semi-hermetic and scroll. R-404A/507, R407A, R407C, R407F, R448A, and R449A available for both medium and low temperature applications Spring-mounted compressors with vibration eliminators on all 1-1/2 to 6 HP semi-hermetic compressors; 1/2 to 1 HP compressors are rigid mounted and have a discharge loop Discharge service valves come standard on all units including hermetics Section 2 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 113

119 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Prepainted galvanized cabinet Head pressure control valve Crankcase heater Fixed low pressure control for M6, & H6 models. Adjustable low pressure control for L6 & X6 models Liquid-line drier assembly Electric defrost timer on L6 and electric defrost kit on L6 Outdoor (T) Prepainted galvanized cabinet Head pressure control valve Crankcase heater Fixed low pressure control for M6, & H6 models. Adjustable low pressure control for L6 & X6 models Configurable s Indoor (N) No cabinet hood Fan guards Wiring conduit Fixed low pressure control for H2, M6, & H6 models. Adjustable low pressure control for L6 & X6 models Beacon II Outdoor (S) Outdoor Unit with hood Head pressure control valve Wired for Beacon II control Beacon II fan cycling for two fan units only Need to customize? Look at the factory-installed options starting on page 119. Section 2 Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Hermetic High Temperature (R-404A/507) Voltage Cabinet Notes BHT005H6BF 5,921 BHT005H6B 5,393 BHN005H6B 4,280 BHS005H6B 5, /1/60 A - BHT009H6BF 6,396 BHT009H6B 5,868 BHN009H6B 4,516 BHS009H6B 6, /1/60 A - BHT010H6BF 6,731 BHT010H6B 6,203 BHN010H6B 4,849 BHS010H6B 6, /1/60 A See footnote 1 BHT010H6CF 6,651 BHT010H6C 6,123 BHN010H6C 4,921 BHS010H6C 6, /3/60 A See footnote 1 BHT015H6BF 7,303 BHT015H6B 6,775 BHN015H6B 5,413 BHS015H6B 7, /1/60 B - BHT015H6CF 7,278 BHT015H6C 6,750 BHN015H6C 5,390 BHS015H6C 7, /3/60 B - BHT025H6BF 8,022 BHT025H6B 7,494 BHN025H6B 6,407 BHS025H6B 8, /1/60 B - BHT025H6CF 7,833 BHT025H6C 7,305 BHN025H6C 6,259 BHS025H6C 7, /3/60 B - BHT032H6BF 8,851 BHT032H6B 8,239 BHN032H6B 7,256 BHS032H6B 8, /1/60 D - BHT032H6CF 8,664 BHT032H6C 8,052 BHN032H6C 7,067 BHS032H6C 8, /3/60 D - Hermetic Extended Temperature (R-404A/507, R407C, R448A, and R449A) BHT005X6BFM 6,078 BHT005X6B 5,550 BHN005X6B 4,438 BHS005X6B 5, /1/60 A See footnote 2 BHT008X6BFM 6,132 BHT008X6B 5,604 BHN008X6B 4,476 BHS008X6B 6, /1/60 A See footnote 2 BHT009X6BFM 6,552 BHT009X6B 6,024 BHN009X6B 4,673 BHS009X6B 6, /1/60 A See footnote 2 BHT010X6BFM 6,888 BHT010X6B 6,360 BHN010X6B 5,005 BHS010X6B 6, /1/60 A See footnote 1, 2 BHT010X6CFM 6,804 BHT010X6C 6,276 BHN010X6C 4,921 BHS010X6C 6, /3/60 A See footnote 1, 2 BHT005X6BFMT 6, /1/60 A See footnote 3 BHT008X6BFMT 6, /1/60 A See footnote 3 BHT009X6BFMT 7, /1/60 A See footnote 3 BHT010X6BFMT 7, /1/60 A See footnote 1, 3 BHT010X6CFMT 7, /3/60 A See footnote 1, 3 Hermetic Extended/Medium Temperature (R-404A/507) BHT015X6BFM 7,459 BHT015X6B 6,931 BHN015X6B 5,567 BHS015X6B 7, /1/60 B See footnote 2 BHT015X6CFM 7,434 BHT015X6C 6,906 BHN015X6C 5,546 BHS015X6C 7, /3/60 B See footnote 2 BHT020X6BFM 7,859 BHT020X6B 7,331 BHN020X6B 5,967 BHS020X6B 8, /1/60 B See footnote 2 BHT020X6CFM 8,015 BHT020X6C 7,487 BHN020X6C 6,126 BHS020X6C 8, /3/60 B See footnote 2 Notes: 1. Not Suitable for R Suction accumulator is available as an option. 3. Includes electric defrost timer. 4. Includes air defrost timer. Suitable for medium temperature applications only. 5. Includes standard liquid line required for liquid injection. 6. provided with Round Tube Plate Fin (RTPF) condenser coil instead of microchannel coil. 7. provided with adjustable low pressure switch. Can also be used for R-407A/F, R-407C and R-448A/449A Medium temperature applications. 114 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

120 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes BHT025X6BFM 8,494 BHT025X6B 7,966 BHN025X6B 6,563 BHS025X6B 8, /1/60 B See footnote 2 BHT025X6CFM 8,345 BHT025X6C 7,817 BHN025X6C 6,415 BHS025X6C 8, /3/60 B See footnote BHT025X6D 8,756 BHN025X6D 7,352 BHS025X6D 9, /3/60 B See footnote 2 BHT030X6BFM 8,528 BHT030X6B 7,916 BHN030X6B 6,932 BHS030X6B 8, /1/60 D See footnote 2 BHT030X6CFM 8,341 BHT030X6C 7,729 BHN030X6C 6,749 BHS030X6C 8, /3/60 D See footnote BHT030X6D 8,683 BHN030X6D 7,702 BHS030X6D 9, /3/60 D See footnote 2 BHT032X6BFM 9,007 BHT032X6B 8,395 BHN032X6B 7,414 BHS032X6B 8, /1/60 D See footnote 2 BHT032X6CFM 8,821 BHT032X6C 8,209 BHN032X6C 7,223 BHS032X6C 8, /3/60 D See footnote BHT032X6D 9,185 BHN032X6D 8,205 BHS032X6D 9, /3/60 D See footnote 2 BHT015X6BFMT 8, /1/60 B See footnote 3 BHT015X6CFMT 7, /3/60 B See footnote 3 BHT020X6BFMT 8, /1/60 B See footnote 3 BHT020X6CFMT 8, /3/60 B See footnote 3 BHT025X6BFMT 9, /1/60 B See footnote 3 BHT025X6CFMT 8, /3/60 B See footnote 3 BHT030X6BFMT 9, /1/60 D See footnote 4 BHT030X6CFMT 8, /3/60 D See footnote 4 BHT032X6BFMT 9, /1/60 D See footnote 4 BHT032X6CFMT 9, /3/60 D See footnote 4 Hermetic Low Temperature (R-404A/507) BHT011L6BF 7,269 BHT011L6B 6,179 BHN011L6B 5,045 BHS011L6B 6, /1/60 A - BHT011L6CF 7,390 BHT011L6C 6,300 BHN011L6C 5,144 BHS011L6C 6, /3/60 A - BHT014L6BF 7,297 BHT014L6B 6,207 BHN014L6B 5,077 BHS014L6B 6, /1/60 A - BHT014L6CF 7,436 BHT014L6C 6,346 BHN014L6C 5,197 BHS014L6C 6, /3/60 A - BHT019L6BF 7,637 BHT019L6B 6,547 BHN019L6B 5,300 BHS019L6B 7, /1/60 B - BHT019L6CF 7,874 BHT019L6C 6,784 BHN019L6C 5,525 BHS019L6C 7, /3/60 B - BHT025L6BF 7,973 BHT025L6B 6,883 BHN025L6B 5,519 BHS025L6B 7, /1/60 B - BHT025L6CF 8,310 BHT025L6C 7,220 BHN025L6C 5,852 BHS025L6C 8, /3/60 B - BHT031L6BF 10,501 BHT031L6B 9,327 BHN031L6B 8,399 BHS031L6B 10, /1/60 C - BHT031L6CF 10,644 BHT031L6C 9,470 BHN031L6C 8,540 BHS031L6C 10, /3/60 C BHT031L6D 9,983 BHN031L6D 9,053 BHS031L6D 10, /3/60 C - Scroll Medium Temperature (R-404A/507, R407A, R407C, R448A, and R449A) - - BZT005M6B 5,851 BZN005M6B 5,501 BZS005M6B 6, /1/60 C BZT005M6C 5,939 BZN005M6C 5,583 BZS005M6C 6, /3/60 C BZT008M6B 6,459 BZN008M6B 6,072 BZS008M6B 6, /1/60 C BZT008M6C 6,556 BZN008M6C 6,162 BZS008M6C 6, /3/60 C BZT009M6B 6,782 BZN009M6B 6,375 BZS009M6B 7, /1/60 C BZT009M6C 6,884 BZN009M6C 6,471 BZS009M6C 7, /3/60 C 7 Section 2 Rev. 01/18 Notes: 1. Not Suitable for R Suction accumulator is available as an option. 3. Includes electric defrost timer. 4. Includes air defrost timer. Suitable for medium temperature applications only. 5. Includes standard liquid line required for liquid injection. Can also be used for R-22 medium and low temperature applications. 6. provided with Round Tube Plate Fin (RTPF) condenser coil instead of microchannel coil. 7. provided with adjustable low pressure switch. Can also be used for R-407A/F, R-407C and R-448A/449A Medium temperature applications. s Effective January 1 st s and specifications subject to change without notice. 115

121 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Section 2 Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes - - BZT010M6B 7,247 BZN010M6B 6,777 BZS010M6B 7, /1/60 C BZT010M6C 7,221 BZN010M6C 6,753 BZS010M6C 7, /3/60 C BZT010M6D 8,061 BZN010M6D 7,539 BZS010M6D 8, /3/60 C BZTX15M6B 8,196 BZNX15M6B 7,666 BZSX15M6B 8, /1/60 C See footnote BZT015M6B 8,196 BZN015M6B 7,666 BZS015M6B 8, /1/60 C BZTX15M6C 8,042 BZNX15M6C 7,521 BZSX15M6C 8, /3/60 C See footnote BZT015M6C 8,042 BZN015M6C 7,521 BZS015M6C 8, /3/60 C BZTX15M6D 8,979 BZNX15M6D 8,398 BZSX15M6D 9, /3/60 C See footnote BZT015M6D 8,979 BZN015M6D 8,398 BZS015M6D 9, /3/60 C BZTX20M6B 8,206 BZNX20M6B 7,557 BZSX20M6B 9, /1/60 C See footnote BZT020M6B 8,206 BZN020M6B 7,557 BZS020M6B 9, /1/60 C BZTX20M6C 8,270 BZNX20M6C 7,619 BZSX20M6C 9, /3/60 C See footnote BZT020M6C 8,270 BZN020M6C 7,619 BZS020M6C 9, /3/60 C BZTX20M6D 8,747 BZNX20M6D 8,093 BZSX20M6D 9, /3/60 C See footnote BZT020M6D 8,747 BZN020M6D 8,093 BZS020M6D 9, /3/60 C BZTX25M6B 8,381 BZNX25M6B 7,728 BZSX25M6B 9, /1/60 C See footnote BZT025M6B 8,381 BZN025M6B 7,728 BZS025M6B 9, /1/60 C BZTX25M6C 8,506 BZNX25M6C 7,859 BZSX25M6C 9, /3/60 C See footnote BZT025M6C 8,506 BZN025M6C 7,859 BZS025M6C 9, /3/60 C BZTX25M6D 8,988 BZNX25M6D 8,335 BZSX25M6D 9, /3/60 C See footnote BZT025M6D 8,988 BZN025M6D 8,335 BZS025M6D 9, /3/60 C BZTX30M6B 9,050 BZNX30M6B 8,396 BZSX30M6B 9, /1/60 C See footnote BZT030M6B 9,050 BZN030M6B 8,396 BZS030M6B 9, /1/60 D BZTX30M6C 9,226 BZNX30M6C 8,576 BZSX30M6C 9, /3/60 D See footnote BZT030M6C 9,226 BZN030M6C 8,576 BZS030M6C 9, /3/60 D BZTX30M6D 9,629 BZNX30M6D 8,975 BZSX30M6D 10, /3/60 D See footnote BZT030M6D 9,629 BZN030M6D 8,975 BZS030M6D 10, /3/60 D BZTX35M6B 10,050 BZNX35M6B 9,396 BZSX35M6B 10, /1/60 D See footnote BZT035M6B 10,050 BZN035M6B 9,396 BZS035M6B 10, /1/60 D BZTX35M6C 10,225 BZNX35M6C 9,575 BZSX35M6C 10, /3/60 D See footnote BZT035M6C 10,225 BZN035M6C 9,575 BZS035M6C 10, /3/60 D BZTX35M6D 10,628 BZNX35M6D 9,975 BZSX35M6D 11, /3/60 D See footnote BZT035M6D 10,628 BZN035M6D 9,975 BZS035M6D 11, /3/60 D BZTX45M6B 10,203 BZNX45M6B 9,256 BZSX45M6B 10, /1/60 D See footnote BZT045M6B 10,203 BZN045M6B 9,256 BZS045M6B 10, /1/60 D BZTX45M6C 9,981 BZNX45M6C 9,034 BZSX45M6C 10, /3/60 D See footnote BZT045M6C 9,981 BZN045M6C 9,034 BZS045M6C 10, /3/60 D BZTX45M6D 11,090 BZNX45M6D 10,145 BZSX45M6D 11, /3/60 D See footnote BZT045M6D 11,090 BZN045M6D 10,145 BZS045M6D 11, /3/60 D - Notes: 1. Not Suitable for R Suction accumulator is available as an option. 3. Includes electric defrost timer. 4. Includes air defrost timer. Suitable for medium temperature applications only. 5. Includes standard liquid line required for liquid injection. Can also be used for R-22 medium and low temperature applications. 6. provided with Round Tube Plate Fin (RTPF) condenser coil instead of microchannel coil. 7. provided with adjustable low pressure switch. Can also be used for R-407A/F, R-407C and R-448A/449A Medium temperature applications. 116 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

122 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes - - BZTX50M6B 11,098 BZNX50M6B 10,150 BZSX50M6B 11, /1/60 D See footnote BZT050M6B 11,098 BZN050M6B 10,150 BZS050M6B 11, /1/60 D BZTX50M6C 10,856 BZNX50M6C 9,911 BZSX50M6C 11, /3/60 D See footnote BZT050M6C 10,856 BZN050M6C 9,911 BZS050M6C 11, /3/60 D BZTX50M6D 12,061 BZNX50M6D 11,114 BZSX50M6D 12, /3/60 D See footnote BZT050M6D 12,061 BZN050M6D 11,114 BZS050M6D 12, /3/60 D BZT055M6B 11,624 BZN055M6B 10,972 BZS055M6B 12, /1/60 D BZT055M6C 11,805 BZN055M6C 11,152 BZS055M6C 12, /3/60 D BZT055M6D 12,205 BZN055M6D 11,549 BZS055M6D 12, /3/60 D - BZT060M6CF 13,834 BZT060M6C 13,222 BZN060M6C 12,556 BZS060M6C 13, /3/60 D See footnote BZT060M6D 13,624 BZN060M6D 12,954 BZS060M6D 14, /3/60 D See footnote 6 Scroll Low Temperature (R-404A/507, R407A, R40C, R407F, R448A, and R449A) - - BZT006L6B 7,500 BZN006L6B 7,050 BZS006L6B 7, /1/60 C See footnote BZT006L6C 7,613 BZN006L6C 7,156 BZS006L6C 8, /3/60 C See footnote BZT008L6B 7,868 BZN008L6B 7,396 BZS008L6B 8, /1/60 C See footnote BZT008L6C 7,986 BZN008L6C 7,507 BZS008L6C 8, /3/60 C See footnote BZT008L6D 8,306 BZN008L6D 7,808 BZS008L6D 8, /3/60 C See footnote BZT010L6B 8,263 BZN010L6B 7,767 BZS010L6B 8, /1/60 C See footnote BZT010L6C 8,387 BZN010L6C 7,884 BZS010L6C 8, /3/60 C See footnote BZT010L6D 8,723 BZN010L6D 8,199 BZS010L6D 9, /3/60 C See footnote BZT022L6B 8,826 BZN022L6B 8,297 BZS022L6B 9, /1/60 C See footnote BZT022L6C 8,959 BZN022L6C 8,421 BZS022L6C 9, /3/60 C See footnote BZT022L6D 9,317 BZN022L6D 8,758 BZS022L6D 9, /3/60 C See footnote BZT025L6B 9,762 BZN025L6B 9,136 BZS025L6B 10, /1/60 C See footnote BZT025L6C 9,936 BZN025L6C 9,308 BZS025L6C 10, /3/60 C See footnote BZT025L6D 10,422 BZN025L6D 9,791 BZS025L6D 11, /3/60 C See footnote BZT030L6B 10,108 BZN030L6B 9,480 BZS030L6B 10, /1/60 C See footnote 5 BZT030L6CF 10,858 BZT030L6C 10,296 BZN030L6C 9,667 BZS030L6C 11, /3/60 C See footnote BZT030L6D 10,784 BZN030L6D 10,157 BZS030L6D 11, /3/60 C See footnote 5 BZT035L6BF 11,658 BZT035L6B 11,096 BZN035L6B 10,469 BZS035L6B 11, /1/60 C See footnote 5 BZT035L6CF 11,832 BZT035L6C 11,270 BZN035L6C 10,644 BZS035L6C 12, /3/60 C See footnote BZT035L6D 11,762 BZN035L6D 11,133 BZS035L6D 12, /3/60 C See footnote BZT045L6B 12,433 BZN045L6B 11,808 BZS045L6B 12, /1/60 D See footnote 5 BZT045L6CF 13,404 BZT045L6C 12,604 BZN045L6C 11,976 BZS045L6C 13, /3/60 D See footnote BZT045L6D 12,989 BZN045L6D 12,359 BZS045L6D 13, /3/60 D See footnote BZT055L6B 12,818 BZN055L6B 12,190 BZS055L6B 13, /1/60 D See footnote 5 BZT055L6CF 13,789 BZT055L6C 12,989 BZN055L6C 12,359 BZS055L6C 13, /3/60 D See footnote BZT055L6D 13,375 BZN055L6D 12,749 BZS055L6D 13, /3/60 D See footnote 5 BZT060L6CF 14,612 BZT060L6C 13,812 BZN060L6C 13,186 BZS060L6C 14, /3/60 D See footnote BZT060L6D 14,196 BZN060L6D 13,570 BZS060L6D 14, /3/60 D See footnote 5 Section 2 Rev. 01/18 Notes: 1. Not Suitable for R Suction accumulator is available as an option. 3. Includes electric defrost timer. 4. Includes air defrost timer. Suitable for medium temperature applications only. 5. Includes standard liquid line required for liquid injection. Can also be used for R-22 medium and low temperature applications. 6. provided with Round Tube Plate Fin (RTPF) condenser coil instead of microchannel coil. 7. provided with adjustable low pressure switch. Can also be used for R-407A/F, R-407C and R-448A/449A Medium temperature applications. s Effective January 1 st s and specifications subject to change without notice. 117

123 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Standard & Configurable s Pricing Section 2 Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Semi-Hermetic Medium Temperature (R-404A/507) Voltage Cabinet Notes - - BST010M6B 7,864 BSN010M6B 6,831 BSS010M6B 8, /1/60 A BST010M6C 7,885 BSN010M6C 6,855 BSS010M6C 8, /3/60 A BST020M6B 10,249 BSN020M6B 9,183 BSS020M6B 11, /1/60 B See footnote BST020M6C 10,093 BSN020M6C 9,011 BSS020M6C 10, /3/60 B See footnote BST021M6C 11,225 BSN021M6C 10,144 BSS021M6C 12, /3/60 B See footnote BST021M6D 11,853 BSN021M6D 10,770 BSS021M6D 12, /3/60 B See footnote BST030M6C 13,388 BSN030M6C 12,439 BSS030M6C 13, /3/60 D See footnote BST030M6D 14,010 BSN030M6D 13,064 BSS030M6D 14, /3/60 D See footnote 6 Semi-Hermetic Low Temperature (R-404A/507) - - BST005L6B 6,949 BSN005L6B 6,107 BSS005L6B 7, /1/60 A BST005L6C 7,035 BSN005L6C 6,192 BSS005L6C 7, /3/60 A BST008L6B 7,512 BSN008L6B 6,478 BSS008L6B 7, /1/60 A BST008L6C 7,531 BSN008L6C 6,498 BSS008L6C 7, /3/60 A BST010L6B 8,023 BSN010L6B 6,993 BSS010L6B 8, /1/60 A BST010L6C 8,031 BSN010L6C 7,006 BSS010L6C 8, /3/60 A - BST015L6BF 10,585 BST015L6B 9,495 BSN015L6B 8,438 BSS015L6B 10, /1/60 B See footnote 6 BST015L6CF 10,548 BST015L6C 9,458 BSN015L6C 8,402 BSS015L6C 10, /3/60 B See footnote BST015L6D 11,170 BSN015L6D 10,102 BSS015L6D 11, /3/60 B See footnote 6 BST020L6CF 12,357 BST020L6C 11,267 BSN020L6C 10,193 BSS020L6C 12, /3/60 B See footnote 6 BST021L6BF 12,813 BST021L6B 11,723 BSN021L6B 10,648 BSS021L6B 12, /1/60 B See footnote 6 BST021L6CF 12,658 BST021L6C 11,568 BSN021L6C 10,492 BSS021L6C 12, /3/60 B See footnote BST021L6D 13,349 BSN021L6D 12,269 BSS021L6D 14, /3/60 B See footnote 6 BST030L6CF 14,580 BST030L6C 13,406 BSN030L6C 12,465 BSS030L6C 14, /3/60 C See footnote BST030L6D 14,539 BSN030L6D 13,484 BSS030L6D 15, /3/60 C See footnote 6 Semi-Hermetic Extra Low Temperature (R-404A/507) BST030E6CF 14,580 BST030E6C 13,406 BSN030E6C 12,465 BSS030E6C 14, /3/60 C See footnote BST030E6D 14,539 BSN030E6D 13,484 BSS030E6D 15, /3/60 C See footnote 6 Notes: 1. Not Suitable for R Suction accumulator is available as an option. 3. Includes electric defrost timer. 4. Includes air defrost timer. Suitable for medium temperature applications only. 5. Includes standard liquid line required for liquid injection. Can also be used for R-22 medium and low temperature applications. 6. provided with Round Tube Plate Fin (RTPF) condenser coil instead of microchannel coil. 7. provided with adjustable low pressure switch. Can also be used for R-407A/F, R-407C and R-448A/449A Medium temperature applications. 118 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

124 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) DFT.001 Defrost Timer - Air All M6, X6 Medium temperature applications only SW.001 Adjustable low pressure control H6, M6 SW.005 Adjustable low pressure control H6, M6 SW.002 Dual pressure control with superhose Standard on L6, E6, X6 models and 005 to 009M6 Scroll models Standard on L6, E6, X6 models and 005 to 009M6 Scroll models All FSD Mounted fused disconnect FSD Mounted fused disconnect ,022-1,022 PLM.004 Phase Loss Monitor All - 1,103 1,103 - FCY.008 Fan Cycling - Fixed Temperature Cabinet B & C 2 fan units; Can't combine HPV & VSEC MS.001A MS.001BC Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with MS.001D Orbus Controller Mechanical Options LIQ LIQ LIQ.003 LIQ LIQ Liquid-line filter drier, sight glass and shut-off valve Liquid-line filter drier, sight glass and shut-off valve Replaceable core liquid-line filter drier, sight glass, shut-off valve Liquid-line solenoid valve and pump-down switch with liquidline filter drier, sight glass and shut-off valve Liquid-line solenoid valve and pump-down switch with liquidline filter drier, sight glass and shut-off valve Cabinet A Cabinet B & C Cabinet D (Except 460V) Cabinet D VSEC with Orbus in place of head pressure control valve VSEC with Orbus in place of head pressure control valve VSEC with Orbus in place of head pressure control valve Standard on L6 models with ZF Scroll Compressor Standard on L6 models with ZF Scroll Compressor Also available on 031 L6 with hermetic compressor Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet ,221-1,221 1,108-1, ,125 1,125 1,125 1,125 1,125-1,210 1,210 - SUC Suction-line filter SUC Suction-line filter SUC.005 Replaceable core suction-line filter Cabinet D Also available on 031 L6 with hermetic compressor 1,170 1,170 1,170 SUC Suction accumulator SUC Suction accumulator DIS.004 DIS.001 Head pressure control flooding valve Oil separator with discharge line check valve Standard 498 Standard Cabinet D Can not be used with 44# reciever with relief valve option (REC.044). 1,265 1,265 - Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 119

125 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code DIS.017 Description s Used On Notes Oil separator with discharge line check valve Cabinet D REC # receiver with relief valve Cabinet D REC.001 PRE.002A PRE.002BC PRE.002D Low ambient kit with heated and insulated reciever, time delay relay Pre-Charged w/ Quick Connects (R404A, R407A, R407C, R407F, R448A, and R449A) Pre-Charged w/ Quick Connects (R404A, R407A, R407C, R407F, R448A, and R449A) Pre-Charged w/ Quick Connects (R404A, R407A, R407C, R407F, R448A, and R449A) All Cabinet A Cabinet B&C Cabinet D Can not be used with 44# reciever with relief valve option (REC.044). Can not be ordered with replaceable core liquid-line filter drier option (LIQ.003). Can not be used with dual pressure control option (SW.002). Must be ordered with liquid-line assemblies. Must be ordered with liquid-line assemblies. Must be ordered with liquid-line assemblies. Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) 1,265 1,265 1,265 1,254 1,254 1, ,052 1, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

126 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Factory-Installed Electric Defrost Options Need an electric defrost timer or kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, find the rated defrost power amps for both the fan motor amps and electric heater amps. If the evaporator total fan motor amps and electric defrost heater amps calculated in Step 1 are less than the condensing unit s rated defrost power amps found in Step 2 then proceed below to select the appropriate kit/components and list price adders. If not then contact your local Sales Representative or Account Engineer for assistance. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Not available on electric defrost timer only options. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Section 2 Option Code DFT.002 DFT.007 SDK.001 Description s Used On Notes Defrost Timer - Electric Electric Defrost Kit InterLink Smart Defrost Kit and L6, M6, E6, X and L6, M6, E6, X and L6, M6, E6, X6 Adder Outdoor (T) Indoor (N) Includes (1) electric defrost timer, (1) heater & (1) fan contactors, and (1) lockout relay. Can not be used alone. Must also select a electric defrost timer or electric defrost kit Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 121

127 Air-Cooled Condensing Units ½ - 6 HP Horizontal Air Discharge Shipped-Loose Accessories Section 2 A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Electrical Options Description s Used On Notes /2" Solenoid valve, 115/230V coil Mechanical Options 10ft Wire harness for air or electric defrost units 15ft Wire harness for air or electric defrost units 20ft Wire harness for air or electric defrost units 25ft Wire harness for air or electric defrost units 35ft Wire harness for air or electric defrost units 55ft Wire harness for air or electric defrost units All Not available for 115V evaporator motors 328 All Not available for 115V evaporator motors 391 All Not available for 115V evaporator motors 423 All Not available for 115V evaporator motors 495 All Not available for 115V evaporator motors 573 All Not available for 115V evaporator motors " Extended legs (shipped-loose) Cabinet A " Extended legs (shipped-loose) Cabinet B&C " Extended legs (shipped-loose) Cabinet D " Extended legs (shipped-loose) Cabinet A " Extended legs (shipped-loose) Cabinet B&C " Extended legs (shipped-loose) Cabinet D Hail guards (shipped-loose) Cabinet A Hail guards (shipped-loose) Cabinet B&C Hail guards (shipped-loose) Cabinet D Precharged Line Set with Refrigerant and Quick Connect Fittings at Both Ends For proper selection, you must know the system capacity, suction temperature, line length, and aeroquip fitting size at both the condensing unit and unit cooler. Please contact your local Sales Representative or Account Engineer for assistance. Line Sizes Part Number Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1,705 7 Feet 10 Feet 15 Feet 20 Feet 30 Feet 50 Feet Part Number Part Number Part Number Part Number Part Number 3/8" x 5/8" ,224 3/8" x 7/8" , ,852 1/2" x 1 1/8" , , , , s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

128 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Overview Product Description: The 3-22 HP condensing units feature an enhanced grill design that gives up to 40% more free-air area than prior models and its vertical receiver needs less refrigerant to ensure a full column of liquid reaches the expansion valve. Fan motors and serviceable components are accessible via the front grill for quick service and the sight glass is conveniently placed so that charging is quick, easy and accurate. Thorough cleaning of the coil is easier because the unit s top panel is one piece and lighter for easy removal. A liquid base valve and suction service tap is placed on the outside of the cabinet for easy pumpdowns and quick diagnosis. The footprint is smaller for easy jobsite placement. These condensing units utilize the Floating Tube coil design, which eliminates tubesheet, allowing for a 5-year warranty against tube-sheet leaks. PSC motors come standard to help save you energy. Opting for the Beacon II Refrigeration System with Smart Defrost, factory-installed Smart Defrost Kit (SDK), Variable Speed EC (VSEC) motor with Orbus Controller increases energy efficiency and qualifies this product for the E Solutions product portfolio Cabinet & Construction All units feature the Floating Tube coil design which eliminates tube sheet leaks Painted steel cabinet for superior strength and corrosion resistance Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Large electrical panel to facilitate ease of access Quality & Performance Sight Glass is easily viewable Fixed high pressure switch eliminates capillary tubes Refrigeration duty, rifled copper condenser tubing Piping is laid out to minimize stress and vibration and is pre-bent to eliminate braze joints where possible to reduce leak potential All joints are sweat type connections, no mechanical joints to leak Separate subcooling circuit in condenser for added capacity and vapor free liquid Pressure relief valve on receiver ServiceMate diagnostic module standard on all non-beacon condensing units Components Compressor Discus compressors are spring mounted with suction and discharge eliminators Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves Other Sight glass and permanent line filter Motors Available with Variable Speed EC Motors Section 2 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 123

129 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Prepainted galvanized cabinet Manual pump-down switch Electronic oil failure switch (Discus Compressors) Spring mounted compressors with suction and discharge vibration eliminators (Discus Compressors) Head pressure control valve Crankcase heater Fixed high and adjustable low pressure switches Sight glass & permanent liquid-line filter ServiceMate Diagnostic Module Outdoor (T) Prepainted galvanized cabinet Manual pump-down switch Electronic oil failure switch (Discus Compressors) Spring mounted compressors with suction and discharge vibration eliminators (Discus Compressors) Head pressure control valve Crankcase heater Fixed high and adjustable low pressure switches Sight glass & permanent liquidline filter Configurable s Indoor (N) No cabinet hood Fan guards & wiring conduit Manual pump-down switch Electronic oil failure switch (Discus Compressors) Spring mounted compressors with suction and discharge vibration eliminators (Discus Compressors) Crankcase heater Fixed high and adjustable low pressure switches Sight glass & permanent liquidline filter Beacon II Outdoor (S) Outdoor Unit with hood Manual pump-down switch Electronic oil failure switch (Discus Compressors) Spring mounted compressors with suction and discharge vibration eliminators (Discus Compressors) Crankcase heater Head pressure control valve Wired for Beacon II control. Beacon II fan cycling for two fan units only Fixed high and adjustable low pressure switches Sight glass & permanent liquid-line filter Need to customize? Look at the factory-installed options starting on page 127. Section 2 Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Discus Medium Temperature (R-404A/507, R407A/R407F, R407C, and R448/R449) Voltage Cabinet Notes - - BDT0500M6C 21,577 BDN0500M6C 21,117 BDS0500M6C 22, /3/60 1 Fan BDT0500M6D 23,005 BDN0500M6D 22,544 BDS0500M6D 23, /3/60 1 Fan BDT0500M6E 23,466 BDN0500M6E 22,994 BDS0500M6E 24, /3/60 1 Fan BDT0501M6C 22,112 BDN0501M6C 21,650 BDS0501M6C 22, /3/60 1 Fan BDT0501M6D 23,541 BDN0501M6D 23,078 BDS0501M6D 24, /3/60 1 Fan BDT0501M6E 24,012 BDN0501M6E 23,541 BDS0501M6E 24, /3/60 1 Fan BDT0750M6C 27,206 BDN0750M6C 26,744 BDS0750M6C 28, /3/60 1 Fan BDT0750M6D 28,632 BDN0750M6D 28,174 BDS0750M6D 30, /3/60 1 Fan BDT0750M6E 29,206 BDN0750M6E 28,734 BDS0750M6E 30, /3/60 1 Fan - BDT0751M6CF 27,376 BDT0751M6C 27,376 BDN0751M6C 26,759 BDS0751M6C 29, /3/60 2 Fan BDT0751M6D 28,801 BDN0751M6D 28,185 BDS0751M6D 30, /3/60 2 Fan BDT0751M6E 29,377 BDN0751M6E 28,749 BDS0751M6E 31, /3/60 2 Fan BDT0800M6C 31,729 BDN0800M6C 31,114 BDS0800M6C 33, /3/60 2 Fan BDT0800M6D 33,242 BDN0800M6D 32,624 BDS0800M6D 35, /3/60 2 Fan BDT0800M6E 33,907 BDN0800M6E 33,277 BDS0800M6E 35, /3/60 2 Fan BDT1000M6C 33,237 BDN1000M6C 32,642 BDS1000M6C 34, /3/60 2 Fan BDT1000M6D 35,604 BDN1000M6D 34,989 BDS1000M6D 37, /3/60 2 Fan BDT1000M6E 36,316 BDN1000M6E 35,687 BDS1000M6E 38, /3/60 2 Fan - BDT1200M6CF 35,983 BDT1200M6C 35,983 BDN1200M6C 35,386 BDS1200M6C 37, /3/60 2 Fan BDT1200M6D 37,521 BDN1200M6D 36,873 BDS1200M6D 39, /3/60 2 Fan BDT1500M6C 36,858 BDN1500M6C 36,262 BDS1500M6C 38, /3/60 2 Fan Large BDT1500M6D 38,589 BDN1500M6D 37,943 BDS1500M6D 40, /3/60 2 Fan Large BDT1500M6E 39,362 BDN1500M6E 38,700 BDS1500M6E 41, /3/60 2 Fan Large - Discus Low Temperature (R-404A/507, R407A/R407F, R407C, and R448A/R449A) - - BDT0300L6C 20,970 BDN0300L6C 20,510 BDS0300L6C 21, /3/60 1 Fan See Note BDT0300L6D 22,394 BDN0300L6D 21,935 BDS0300L6D 23, /3/60 1 Fan See Note BDT0300L6E 22,844 BDN0300L6E 22,375 BDS0300L6E 23, /3/60 1 Fan See Note BDT0400L6C 22,794 BDN0400L6C 22,333 BDS0400L6C 23, /3/60 1 Fan See Note BDT0400L6D 24,220 BDN0400L6D 23,757 BDS0400L6D 25, /3/60 1 Fan See Note BDT0400L6E 24,702 BDN0400L6E 24,233 BDS0400L6E 25, /3/60 1 Fan See Note 1 Notes: 1. For R407A/R407F, R407C, and R448A/R449A low temperature operation, add Demand Cooling Kit. 124 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

130 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes - - BDT0600L6C 23,951 BDN0600L6C 23,489 BDS0600L6C 24, /3/60 1 Fan See Note BDT0600L6D 25,377 BDN0600L6D 24,916 BDS0600L6D 26, /3/60 1 Fan See Note BDT0600L6E 25,884 BDN0600L6E 25,414 BDS0600L6E 26, /3/60 1 Fan See Note 1 BDT0601L6CF 26,657 BDT0601L6C 25,365 BDN0601L6C 24,904 BDS0601L6C 26, /3/60 1 Fan See Note BDT0601L6D 26,788 BDN0601L6D 26,329 BDS0601L6D 27, /3/60 1 Fan See Note BDT0601L6E 27,325 BDN0601L6E 26,855 BDS0601L6E 28, /3/60 1 Fan See Note 1 BDT0750L6CF 30,924 BDT0750L6C 29,633 BDN0750L6C 29,171 BDS0750L6C 31, /3/60 1 Fan See Note BDT0750L6D 31,060 BDN0750L6D 30,598 BDS0750L6D 32, /3/60 1 Fan See Note BDT0750L6E 31,682 BDN0750L6E 31,208 BDS0750L6E 33, /3/60 1 Fan See Note BDT0900L6C 32,589 BDN0900L6C 31,974 BDS0900L6C 34, /3/60 2 Fan See Note BDT0900L6D 34,013 BDN0900L6D 33,396 BDS0900L6D 35, /3/60 2 Fan See Note BDT0900L6E 34,695 BDN0900L6E 34,067 BDS0900L6E 36, /3/60 2 Fan See Note 1 BDT1000L6CF 36,503 BDT1000L6C 35,062 BDN1000L6C 34,444 BDS1000L6C 36, /3/60 2 Fan See Note BDT1000L6D 35,798 BDN1000L6D 35,179 BDS1000L6D 37, /3/60 2 Fan See Note BDT1000L6E 36,512 BDN1000L6E 35,883 BDS1000L6E 38, /3/60 2 Fan See Note BDT1200L6C 35,791 BDN1200L6C 35,145 BDS1200L6C 37, /3/60 2 Fan Large See Note BDT1200L6D 37,019 BDN1200L6D 36,371 BDS1200L6D 38, /3/60 2 Fan Large See Note BDT1200L6E 37,758 BDN1200L6E 37,098 BDS1200L6E 39, /3/60 2 Fan Large See Note BDT1500L6C 37,392 BDN1500L6C 36,745 BDS1500L6C 39, /3/60 2 Fan Large See Note BDT1500L6D 40,317 BDN1500L6D 39,669 BDS1500L6D 42, /3/60 2 Fan Large See Note BDT1500L6E 41,125 BDN1500L6E 40,463 BDS1500L6E 42, /3/60 2 Fan Large See Note BDT2200L6C 43,788 BDN2200L6C 43,141 BDS2200L6C 45, /3/60 2 Fan Large See Note BDT2200L6D 44,340 BDN2200L6D 44,090 BDS2200L6D 46, /3/60 2 Fan Large See Note BDT2200L6E 45,226 BDN2200L6E 44,565 BDS2200L6E 46, /3/60 2 Fan Large See Note 1 Scroll Medium Temperature (R-404A/507, R407A/R407F, R407C, and R448A/R449A) - - BZT0650M6C 23,808 BZN0650M6C 23,346 BZS0650M6C 25, /3/60 1 Fan BZT0650M6D 25,355 BZN0650M6D 24,893 BZS0650M6D 26, /3/60 1 Fan BZT0650M6E 25,860 BZN0650M6E 25,393 BZS0650M6E 27, /3/60 1 Fan BZT0700M6C 23,864 BZN0700M6C 23,401 BZS0700M6C 25, /3/60 2 Fan BZT0700M6D 25,414 BZN0700M6D 24,953 BZS0700M6D 27, /3/60 2 Fan BZT0700M6E 25,954 BZN0700M6E 25,492 BZS0700M6E 27, /3/60 2 Fan BZT0750M6C 24,978 BZN0750M6C 24,362 BZS0750M6C 26, /3/60 2 Fan BZT0750M6D 26,527 BZN0750M6D 25,911 BZS0750M6D 28, /3/60 2 Fan BZT0750M6E 27,055 BZN0750M6E 26,425 BZS0750M6E 28, /3/60 2 Fan BZT0860M6C 29,605 BZN0860M6C 28,990 BZS0860M6C 31, /3/60 2 Fan BZT0860M6D 30,311 BZN0860M6D 29,697 BZS0860M6D 32, /3/60 2 Fan BZT0860M6E 30,917 BZN0860M6E 30,290 BZS0860M6E 32, /3/60 2 Fan BZT1000M6C 32,553 BZN1000M6C 30,760 BZS1000M6C 34, /3/60 2 Fan BZT1000M6D 32,817 BZN1000M6D 31,025 BZS1000M6D 34, /3/60 2 Fan BZT1000M6E 33,473 BZN1000M6E 31,645 BZS1000M6E 35, /3/60 2 Fan BZT1401M6C 36,347 BZN1401M6C 34,453 BZS1401M6C 38, /3/60 2 Fan Large BZT1401M6D 37,758 BZN1401M6D 34,728 BZS1401M6D 38, /3/60 2 Fan Large BZT1401M6E 37,354 BZN1401M6E 35,421 BZS1401M6E 39, /3/60 2 Fan Large - Scroll Low Temperature (R-404A/507, R-407A/R407F, R-407C, R-448A/R-449A) - - BZT0750L6C 22,511 BZN0750L6C 22,048 BZS0750L6C 23, /3/60 1 Fan BZT0750L6D 23,896 BZN0750L6D 23,436 BZS0750L6D 25, /3/60 1 Fan BZT0750L6E 24,373 BZN0750L6E 23,903 BZS0750L6E 25, /3/60 1 Fan BZT1000L6C 27,942 BZN1000L6C 27,482 BZS1000L6C 29, /3/60 1 Fan - Section 2 Notes: 1. For R407A/R407F, R407C, and R448A/R449A low temperature operation, add Demand Cooling Kit. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 125

131 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Standard & Configurable s Pricing Standard Outdoor Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes - - BZT1000L6D 29,392 BZN1000L6D 28,930 BZS1000L6D 30, /3/60 1 Fan BZT1000L6E 29,980 BZN1000L6E 29,509 BZS1000L6E 31, /3/60 1 Fan BZT1300L6C 31,375 BZN1300L6C 30,760 BZS1300L6C 33, /3/60 2 Fan BZT1300L6D 32,122 BZN1300L6D 31,506 BZS1300L6D 33, /3/60 2 Fan BZT1300L6E 32,765 BZN1300L6E 32,137 BZS1300L6E 34, /3/60 2 Fan BZT1500L6C 32,401 BZN1500L6C 31,787 BZS1500L6C 34, /3/60 2 Fan BZT1500L6D 33,150 BZN1500L6D 32,533 BZS1500L6D 34, /3/60 2 Fan BZT1500L6E 33,811 BZN1500L6E 33,184 BZS1500L6E 35, /3/60 2 Fan - Section 2 Notes: 1. For R407A/R407F, R407C, and R448A/R449A low temperature operation, add Demand Cooling Kit. 126 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

132 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On DFT.001 Defrost Timer - Air All M6 SW.007 SW.002 Adjustable high pressure switch w/ manual reset & adjustable low pressure switch Dual pressure control with adjustable high & low pressure settings 2 Fan & 2 Fan Large All Notes Medium temperature applications only. Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) Standard heated and insulated receiver kit option can't be used with this option. Contact factory FSD Mounted fused disconnect 1 Fan (230V) - 1,064-1,064 FSD Mounted fused disconnect 1 Fan (460V) - 2,152-1,869 FSD Mounted fused disconnect 2 Fan (230V) - 1,869-1,869 FSD Mounted fused disconnect 2 Fan (460V) - 2,152-2,152 FSD Mounted fused disconnect 2 Fan Large (230V) - 2,152-2,152 FSD Mounted fused disconnect 2 Fan Large (460V) - 3,520-3,520 PLM.001 Phase Loss Monitor All - 1,153 1,153 1,153 FCY Fan Cycling - Temperature & Pressure 1 Fan Press. Std. FCY.014 Fan Cycling - Temperature & Pressure 2 Fan Press. Std. FCY Fan Cycling - Temperature & Pressure 2 Fan Large Press. Std. ELC ELC Circuit Breakers (Compressor, Control & Fan) Circuit Breakers (Compressor, Control & Fan) 2 Fan Large - 230V - 2,399 2,399-2 Fan Large - 460V - 3,643 3,643 - CFS.001 Compressor Fusing 2 Fan Large ELC NEMA Contactors 2 Fan Large - 230V - 2,193 2,193 - ELC NEMA Contactors 2 Fan Large - 460V - 1,272 1,272 - MS MS MS MS Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller 1 Fan ( /3/60) 2 Fan ( /3/60) - 1,108-1,108 Not suitable for 2 Fan Large (230V) Units (1401H6, 1500M6, 1200L6 2200L6) 1,966-1,966 2 Fan Large (230V) - N/A - N/A 1 Fan (460V) - 2,763-2,763 Section 2 Rev. 01/18 Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1.All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2.All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically s Effective January 1 st s and specifications subject to change without notice. 127

133 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code MS MS Mechanical Options LIQ.003 Description Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Replaceable core liquid-line filter drier & sight glass s Used On 2 Fan (460V) LIQ Liquid-line solenoid valve 1 Fan LIQ Liquid-line solenoid valve 2 Fan LIQ Liquid-line solenoid valve 2 Fan Large Notes Not suitable for 2 Fan Large (460V) Units (1401H6, 1500M6, 1200L6-2200L6) Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) 3,749-3,749 2 Fan Large (460V) - N/A - N/A All Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet SUC Suction-line filter 1 Fan SUC Suction-line filter 2 Fan SUC Suction-line filter 2 Fan Large - 1,290 1,290 1,290 SUC Replaceable core suction-line filter 1 Fan SUC Replaceable core suction-line filter 2 Fan - 1,247 1,247 1,247 SUC Replaceable core suction-line filter 2 Fan Large - 1,688 1,688 1,688 SUC Suction accumulator 1 Fan SUC Suction accumulator 2 Fan - 1,137 1,137 1,137 SUC Suction accumulator 2 Fan Large - 2,755 2,755 2,755 DIS DIS DIS DIS DIS Head pressure control valve - 180psi fixed Head pressure control valve - adjustable Oil separator with discharge line check valve Oil separator with discharge line check valve Oil separator with discharge line check valve 1 & 2 Fan - Standard 357 Standard 2 Fan Large - Standard 1,211 Standard 1 Fan - 1,323 1,323 1,323 2 Fan - 1,397 1,397 1,397 2 Fan Large - 1,653 1,653 1,653 UNL.001 Compressor Unloading (One Step) 2 Fan Large - 2,281 2,281 - DMD.001 Demand Cooling for low temperature R-407A/R-407F, R-407C, and R-448A/R-449A All L6 Discuss Compressors Only 2,390 2,390 2,390 REC Oversized receiver 1 Fan See technical bulletin for volumes 1,246 1,246 1,246 REC Oversized receiver 2 Fan See technical bulletin for volumes s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

134 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Description s Used On Notes Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) REC Oversized receiver 2 Fan Large See technical bulletin for Volumes LOW LOW Heated & Insulated reciever with low pressure cut-out time delay Heated & Insulated reciever with low pressure cut-out time delay 1 & 2 Fan Fan Large - 1,069-1,069 LVR Louvered guard for snowbelt regions 1 Fan - 1,211-1,211 LVR Louvered guard for snowbelt regions 2 Fan - 1,379-1,379 Coil Options CS.PRO-1 CS.PRO-2 CS.PRO-3 Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection 1 Fan - 1,242 1,242 1,242 2 Fan - 1,716 1,716 1,716 2 Fan Large - 2,411 2,411 2,411 CS.CPR-1 Copper condenser fins 1 Fan - Call Factory Call Factory Call Factory CS.CPR-2 Copper condenser fins 2 Fan - Call Factory Call Factory Call Factory CS.CPR-3 Copper condenser fins 2 Fan Large - Call Factory Call Factory Call Factory CS.ELEC-1 ElectroFin coil coating 1 Fan - Call Factory Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating 2 Fan - Call Factory Call Factory Call Factory CS.ELEC-3 ElectroFin coil coating 2 Fan Large - Call Factory Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating 1 Fan - Call Factory Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating 2 Fan - Call Factory Call Factory Call Factory CS.BRZ-3 Bronz-Glow coil coating 2 Fan Large - Call Factory Call Factory Call Factory Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 129

135 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Need an electric defrost kit? Factory-Installed Electric Defrost Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Section 2 Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, find the rated defrost power amps for both the fan motor amps and electric heater amps. If the evaporator total fan motor amps and electric defrost heater amps calculated in Step 1 are less than the condensing unit s rated defrost power amps found in Step 2 then proceed below to select the appropriate kit/components and list price adders. If not then contact your local Sales Representative or Account Engineer for assistance. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Option Code DFT DFT DFT.028 DFT.029 DEF.066 DEF.067 EHR.001 SDK.001 Description s Used On Notes Electric Defrost Kit (High Amps) Electric Defrost Kit (High Amps) Electric Defrost Kit (Low Amps) Electric Defrost Kit (High Amps) Fuses for electric defrost kits Fuses for electric defrost kits Evaporator hold out relay InterLink Smart Defrost Kit 1 Fan 2 Fan 2 Fan Large 2 Fan Large Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Adder Outdoor (T) Indoor (N) 1,292 1,292 1,441 1,441 1,956 1,956 2,814 2,814 1 & 2 Fan Fan Large Fan Large All Can not be used alone. Must also select a electric defrost timer or electric defrost kit s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

136 Air-Cooled Condensing Units 3-22 HP Horizontal Air Discharge Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Mechanical Options Description s Used On Notes " Extended Legs 1 Fan & 2 Fan " Extended Legs 2 Fan Large Hail Guards 1 Fan Hail Guards 2 Fan Hail Guards 2 Fan Large Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1, /8" 4262Q 2,669 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 131

137 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Overview Section 2 Product Description: The 4-13 HP condensing unit product line with Bitzer compressors feature an enhanced grill design that gives up to 40% more free-air area than prior models and its vertical receiver needs less refrigerant to ensure a full column of liquid reaches the expansion valve. Fan motors and serviceable components are accessible via the front grill for quick service and the sight glass is conveniently placed so that charging is quick, easy and accurate. Thorough cleaning of the coil is easier because the unit s top is one piece and lighter for easy removal. A liquid base valve and suction service tap is placed on the outside of the cabinet for easy pump-downs and quick diagnosis. The footprint is smaller for easy jobsite placement. These condensing units utilize the Floating Tube design, which eliminates tube-sheet leaks, allowing a 5-year warranty against tube-sheet leaks. PSC motors come standard to help you save money Opting for the Beacon II Refrigeration System with Smart Defrost, factory-installed Smart Defrost Kit (SDK), Variable Speed EC (VSEC) motor with Orbus Controller increases energy efficiency and qualifies this product for the E Solutions product portfolio Cabinet & Construction All units feature the Floating Tube coil design, eliminating tube sheet leaks Painted steel cabinet for superior strength and corrosion resistance Enhanced grill design provides 25-40% increase in free-air area Serviceability Manual pumpdown switch on all units Dual isolation valves on receiver Base valve and high/low pressure taps on outside of cabinet Removable grill for access to all serviceable parts Lighter, one-piece top is easily removed for improved serviceability Quality Sight Glass is easily viewable Fixed high and adjustable low pressure switch Refrigeration duty, rifled copper condenser tubing Electrical box relocated outside of air stream (improved air flow) Piping is laid out to minimize stress and vibration and is pre-bent to eliminate braze joints where possible, to reduce leak potential Components Compressor Units feature Bitzer semi-hermetic compressors. Available with compressor unloading Other Crankcase heater and head pressure valve on all outdoor units Sight glass and permanent liquid line filter Motors Available with Variable Speed EC Motors Certifications Nomenclature 132 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

138 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Configurable s Pricing Outdoor (T) Prepainted galvanized cabinet Manual pump-down switch Electronic oil failure switch Spring mounted compressors with suction and discharge vibration eliminators Head pressure control valve Crankcase heater Fixed high and adjustable low pressure switches Sight glass & permanent liquid-line filter ServiceMate Diagnostic Module Configurable s Indoor (N) No cabinet hood Fan guards & wiring conduit Manual pump-down switch Electronic oil failure switch Spring mounted compressors with suction and discharge vibration eliminators Crankcase heater Fixed high and adjustable low pressure switches Sight glass & permanent liquid-line filter ServiceMate Diagnostic Module Beacon II Outdoor (S) Outdoor Unit with hood Manual pump-down switch Spring mounted compressors with suction and discharge vibration eliminators Crankcase heater Head pressure control valve Wired for Beacon II control. Beacon II fan cycling for two fan units only Fixed high and adjustable low pressure switches Sight glass & permanent liquid-line filter Need to customize? Look at the factory-installed options starting on page 135. Outdoor (T) Indoor (N) Beacon II Outdoor (S) Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) Voltage Cabinet Notes BBT0551M6C 24,346 BBN0551M6C 23,884 BBS0551M6C 25, /3/60 2 Fan - BBT0551M6D 25,563 BBN0551M6D 25,078 BBS0551M6D 26, /3/60 2 Fan - BBT0551M6E 26,074 BBN0551M6E 25,578 BBS0551M6E 27, /3/60 2 Fan - BBT0751M6C 27,376 BBN0751M6C 26,855 BBS0751M6C 28, /3/60 2 Fan - BBT0751M6D 28,745 BBN0751M6D 28,199 BBS0751M6D 30, /3/60 2 Fan - BBT0751M6E 29,319 BBN0751M6E 28,760 BBS0751M6E 30, /3/60 2 Fan - BBT0901M6C 32,443 BBN0901M6C 31,826 BBS0901M6C 34, /3/60 2 Fan Large - BBT0901M6D 34,065 BBN0901M6D 33,417 BBS0901M6D 35, /3/60 2 Fan Large - BBT0901M6E 34,745 BBN0901M6E 34,086 BBS0901M6E 36, /3/60 2 Fan Large - BBT1001M6C 33,068 BBN1001M6C 32,441 BBS1001M6C 34, /3/60 2 Fan Large - BBT1001M6D 34,721 BBN1001M6D 34,061 BBS1001M6D 36, /3/60 2 Fan Large - BBT1001M6E 35,416 BBN1001M6E 34,743 BBS1001M6E 37, /3/60 2 Fan Large - Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) BBT0401L6C 22,794 BBN0401L6C 22,385 BBS0401L6C 23, /3/60 1 Fan - BBT0401L6D 23,684 BBN0401L6D 23,258 BBS0401L6D 24, /3/60 1 Fan - BBT0401L6E 24,163 BBN0401L6E 23,728 BBS0401L6E 25, /3/60 1 Fan - BBT0551L6C 23,951 BBN0551L6C 23,522 BBS0551L6C 25, /3/60 1 Fan - BBT0551L6D 24,886 BBN0551L6D 24,437 BBS0551L6D 25, /3/60 1 Fan - BBT0551L6E 25,390 BBN0551L6E 24,932 BBS0551L6E 26, /3/60 1 Fan - BBT0601L6C 28,738 BBN0601L6C 28,220 BBS0601L6C 29, /3/60 2 Fan - BBT0601L6D 29,858 BBN0601L6D 29,321 BBS0601L6D 31, /3/60 2 Fan - BBT0601L6E 30,462 BBN0601L6E 29,915 BBS0601L6E 31, /3/60 2 Fan - BBT0611L6C 29,431 BBN0611L6C 28,901 BBS0611L6C 30, /3/60 2 Fan - BBT0611L6D 30,578 BBN0611L6D 30,029 BBS0611L6D 31, /3/60 2 Fan - BBT0611L6E 31,197 BBN0611L6E 30,635 BBS0611L6E 32, /3/60 2 Fan - BBT0751L6C 30,692 BBN0751L6C 30,140 BBS0751L6C 32, /3/60 2 Fan - BBT0751L6D 31,890 BBN0751L6D 31,314 BBS0751L6D 33, /3/60 2 Fan - Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 133

139 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Configurable s Pricing Outdoor (T) Indoor (N) Beacon II Outdoor (S) Voltage Cabinet Notes BBT0751L6E 32,534 BBN0751L6E 31,949 BBS0751L6E 33, /3/60 2 Fan - BBT1001L6C 35,062 BBN1001L6C 34,430 BBS1001L6C 36, /3/60 2 Fan - BBT1001L6D 36,428 BBN1001L6D 35,773 BBS1001L6D 38, /3/60 2 Fan - BBT1001L6E 37,164 BBN1001L6E 36,497 BBS1001L6E 38, /3/60 2 Fan - BBT1201L6C 35,791 BBN1201L6C 35,146 BBS1201L6C 37, /3/60 2 Fan Large - BBT1201L6D 37,186 BBN1201L6D 36,516 BBS1201L6D 38, /3/60 2 Fan Large - BBT1201L6E 37,937 BBN1201L6E 37,255 BBS1201L6E 39, /3/60 2 Fan Large - BBT1301L6C 37,392 BBN1301L6C 36,720 BBS1301L6C 39, /3/60 2 Fan Large - BBT1301L6D 38,851 BBN1301L6D 38,151 BBS1301L6D 40, /3/60 2 Fan Large - BBT1301L6E 39,636 BBN1301L6E 38,923 BBS1301L6E 41, /3/60 2 Fan Large - Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

140 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes DFT.001 Defrost Timer - Air All M6 SW.007 SW.002 Adjustable high pressure switch w/ manual reset & adjustable low pressure switch Dual pressure control with adjustable high & low pressure settings Medium temperature applications only. Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) All All Standard heated and insulated receiver kit option can't be used with this option. Contact factory FSD Mounted fused disconnect 1 Fan (230V) - 1,064-1,064 FSD Mounted fused disconnect 1 Fan (460V) - 2,763-2,763 FSD Mounted fused disconnect 2 Fan (230V) - 1,869-1,869 FSD Mounted fused disconnect 2 Fan (460V) Not suitable for 2 Fan Large (460V) Units (901M6-1001M6, 1201L6-1301L6) 3,749-3,749 FSD Mounted fused disconnect 2 Fan Large (230V) - 2,570-2,570 FSD Mounted fused disconnect 2 Fan Large (460V) - 3,520-3,520 PLM.001 Phase Loss Monitor All - 1,153 1,153 1,153 FCY Fan Cycling - Temperature & Pressure 1 Fan Press. Std. FCY.014 Fan Cycling - Temperature & Pressure 2 Fan Press. Std. FCY Fan Cycling - Temperature & Pressure 2 Fan Large Press. Std. ELC Circuit Breakers (Compressor, Control & Fan) 2 Fan Large - 230V - 2,399 2,399 - ELC Circuit Breakers (Compressor, Control & Fan) 2 Fan Large - 460V - 3,643 3,643 - CFS.001 Compressor Fusing 2 Fan Large ELC NEMA Contactors 2 Fan Large - 230V - 2,193 2,193 - ELC NEMA Contactors 2 Fan Large - 460V - 1,272 1,272 - MS MS MS MS MS MS Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller Variable Speed EC Motor with Orbus Controller 1 Fan ( /3/60) 2 Fan ( /3/60) - 1,186-1,186 Not suitable for 2 Fan Large (230V) Units (901M6-1001M6, 1201L6-1301L6) 1,928-1,928 2 Fan Large (230V) - N/A - N/A 1 Fan (460V) - 2,763-2,763 2 Fan (460V) Not suitable for 2 Fan Large (460V) Units (901M6-1001M6, 1201L6 1301L6) 3,749-3,749 2 Fan Large (460V) - N/A - N/A Section 2 Rev. 01/18 Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. s Effective January 1 st s and specifications subject to change without notice. 135

141 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code Description s Used On Notes Mechanical Options Replaceable core liquid-line filter drier & sight LIQ.003 glass LIQ Liquid-line solenoid valve 1 Fan LIQ Liquid-line solenoid valve 2 Fan LIQ Liquid-line solenoid valve 2 Fan Large Outdoor (T) Adder Indoor (N) Beacon II Outdoor (S) All Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet SUC Suction-line filter 1 Fan SUC Suction-line filter 2 Fan SUC Suction-line filter 2 Fan Large - 1,290 1,290 1,290 SUC Replaceable core suction-line filter 1 Fan SUC Replaceable core suction-line filter 2 Fan - 1,247 1,247 1,247 SUC Replaceable core suction-line filter 2 Fan Large - 1,688 1,688 1,688 SUC Suction accumulator 1 Fan SUC Suction accumulator 2 Fan - 1,137 1,137 1,137 SUC Suction accumulator 2 Fan Large - 2,755 2,755 2,755 DIS Head pressure control valve - 180psi fixed 1 & 2 Fan - Standard 357 Standard DIS Head pressure control valve - adjustable 2 Fan Large - Standard 1,211 Standard DIS Oil separator with discharge line check valve 1 Fan - 1,323 1,323 1,323 DIS Oil separator with discharge line check valve 2 Fan - 1,397 1,397 1,397 DIS Oil separator with discharge line check valve 2 Fan Large - 1,653 1,653 1,653 UNL.001 Compressor Unloading (One Step) All - 2,281 2,281 - REC Oversized receiver 1 Fan See technical bulletin for volumes 1,246 1,246 1,246 REC Oversized receiver 2 Fan See technical bulletin for volumes REC Oversized receiver 2 Fan Large See technical bulletin for Volumes LOW LOW Heated & Insulated reciever with low pressure cut-out time delay Heated & Insulated reciever with low pressure cut-out time delay 1 & 2 Fan Fan Large - 1,069-1,069 LVR Louvered guard for snowbelt regions 1 Fan - 1,211-1,211 LVR Louvered guard for snowbelt regions 2 Fan - 1,379-1,379 Coil Options CS.PRO-1 Guard condenser fin protection 1 Fan - 1,242 1,242 1,242 CS.PRO-2 Guard condenser fin protection 2 Fan - 1,716 1,716 1,716 CS.PRO-3 Guard condenser fin protection 2 Fan Large - 2,411 2,411 2,411 CS.CPR-1 Copper condenser fins 1 Fan - Call Factory Call Factory Call Factory CS.CPR-2 Copper condenser fins 2 Fan - Call Factory Call Factory Call Factory CS.CPR-3 Copper condenser fins 2 Fan Large - Call Factory Call Factory Call Factory CS.ELEC-1 ElectroFin coil coating 1 Fan - Call Factory Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating 2 Fan - Call Factory Call Factory Call Factory CS.ELEC-3 ElectroFin coil coating 2 Fan Large - Call Factory Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating 1 Fan - Call Factory Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating 2 Fan - Call Factory Call Factory Call Factory CS.BRZ-3 Bronz-Glow coil coating 2 Fan Large - Call Factory Call Factory Call Factory 136 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

142 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Factory-Installed Electric Defrost Options Need an electric defrost kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, contact your local Sales Representative or Account Engineer to find out the rated defrost power amps for both the fan motor amps and electric heater amps. The condensing unit data plate ratings are based on the actual system match. Your local Sales Representative or Account Engineer will help you select the proper electric defrost kit and components. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Section 2 Option Code Description s Used On Notes DFT.KIT Electric Defrost Kit All DFT.CHR SDK.001 Additional Heater Contactor and hold out relay InterLink Smart Defrost Kit All All Includes (1) electric defrost timer, (1) heater contactor (48 amp maximum heater load), (1) fan contactor, terminal strip, and fusing 48 amp maximum heater load per heater contactor. Can only have a maximum of 2 heater contactors per unit. Can not be used alone. Must also select a electric defrost timer or electric defrost kit. Adder Outdoor (T) Indoor (N) 1,901 1, Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 137

143 Air-Cooled Condensing Units 4-13 HP Horizontal Air Discharge Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Mechanical Options Description s Used On Notes " Extended Legs 1 Fan & 2 Fan " Extended Legs 2 Fan Large Hail Guards 1 Fan Hail Guards 2 Fan Hail Guards 2 Fan Large Section 2 Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1, /8" 4262Q 2, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

144 Air-Cooled Condensing Units HP Vertical Air Discharge Overview Product Description The HP vertical condensing units are designed to meet the needs of a demanding commercial and industrial refrigeration market. The product is configured to be flexible in its design and construction to allow it to respond to the requirements of refrigeration contractors, consulting engineers and facility owners/operators. The Floating Tube coil design incorporated in the product provides reliability against tube sheet leaks. Opting for the Beacon II refrigeration system with Smart Defrost, Factory installed Smart Defrost Kit (SDK) or Variable Speed EC motors increases this products energy efficiency and qualifies it for the E Solutions product portfolio. Certifications Cabinet & Construction All units feature the Floating Tube coil which eliminates tube sheet leaks Painted steel cabinet for superior strength and corrosion resistance Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Large electrical panel to facilitate ease of access Quality Sight Glass is easily viewable Fixed high and adjustable low pressure switch Refrigeration duty, rifled copper condenser tubing Piping is laid out to minimize stress and vibration and is pre-bent to eliminate braze joints where possible to reduce leak potential All joints are sweat type connections, no mechanical joints to leak Separate subcooling circuit in condenser for added capacity and vapor free liquid Pressure relief valve on receiver ServiceMate diagnostic module standard on all non-beacon condensing units Components Compressor Spring-mounted compressors with suction and discharge eliminators Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves. Other Sight glass and permanent liquid line filter Motors Available with Variable Speed EC Motors Section 2 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 139

145 Air-Cooled Condensing Units HP Vertical Air Discharge Configurable s Pricing Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Adjustable flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose ServiceMate Diagnostic Module Configurable s Need to customize? Look at the factory-installed options starting on page 143. Beacon II Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Adjustable flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose Wired for Beacon II control with fan cycling. Section 2 Outdoor Beacon II Outdoor Voltage Type Notes Standard s: Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) BLV1500M6C 38,290 BDVS1500M6C 41, /3/60 Standard - BLV1500M6D 39,047 BDVS1500M6D 41, /3/60 Standard - BLV1500M6E 39,826 BDVS1500M6E 42, /3/60 Standard - BLV2000M6C 42,608 BDVS2000M6C 45, /3/60 Standard - BLV2000M6D 43,364 BDVS2000M6D 46, /3/60 Standard - BLV2000M6E 44,232 BDVS2000M6E 47, /3/60 Standard - BLV2500M6C 50,836 BDVS2500M6C 53, /3/60 Standard - BLV2500M6D 51,591 BDVS2500M6D 54, /3/60 Standard - BLV2500M6E 52,623 BDVS2500M6E 55, /3/60 Standard - BLV2600M6C 57,097 BDVS2600M6C 59, /3/60 Standard - BLV2600M6D 57,851 BDVS2600M6D 60, /3/60 Standard - BLV2600M6E 59,010 BDVS2600M6E 61, /3/60 Standard - BLV3000M6C 59,622 BDVS3000M6C 62, /3/60 Standard - BLV3000M6D 60,380 BDVS3000M6D 63, /3/60 Standard - BLV3000M6E 61,587 BDVS3000M6E 64, /3/60 Standard - BLV3500M6C 67,488 BDVS3500M6C 70, /3/60 Standard - BLV3500M6D 68,110 BDVS3500M6D 71, /3/60 Standard - BLV3500M6E 69,474 BDVS3500M6E 72, /3/60 Standard - BLV4000M6D 75,474 BDVS4000M6D 78, /3/60 Standard - BLV4000M6K 74,459 BDVS4000M6K 77, /3/60 Standard - BLV4000M6E 76,982 BDVS4000M6E 80, /3/60 Standard - Standard s: Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) BLV1200L6C 39,263 BDVS1200L6C 42, /3/60 Standard See Note 2 BLV1200L6D 40,023 BDVS1200L6D 42, /3/60 Standard See Note 2 BLV1200L6E 40,821 BDVS1200L6E 43, /3/60 Standard See Note 2 Notes: 1. High Efficiency s come with an oversized condenser. 2. For R-407A/R-407F, R407C, and R-448A/R-449A low temperature operation, add Demand Cooling Kit. 140 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

146 Air-Cooled Condensing Units HP Vertical Air Discharge Configurable s Pricing Outdoor Beacon II Outdoor Voltage Type Notes BLV1500L6C 41,100 BDVS1500L6C 43, /3/60 Standard See Note 2 BLV1500L6D 41,857 BDVS1500L6D 44, /3/60 Standard See Note 2 BLV1500L6E 42,695 BDVS1500L6E 45, /3/60 Standard See Note 2 BLV2200L6C 48,235 BDVS2200L6C 51, /3/60 Standard See Note 2 BLV2200L6D 48,993 BDVS2200L6D 51, /3/60 Standard See Note 2 BLV2200L6E 49,972 BDVS2200L6E 52, /3/60 Standard See Note 2 BLV2700L6C 55,440 BDVS2700L6C 58, /3/60 Standard See Note 2 BLV2700L6D 56,195 BDVS2700L6D 59, /3/60 Standard See Note 2 BLV2700L6E 57,320 BDVS2700L6E 60, /3/60 Standard See Note 2 BLV3000L6C 61,515 BDVS3000L6C 64, /3/60 Standard See Note 2 BLV3000L6D 62,270 BDVS3000L6D 65, /3/60 Standard See Note 2 BLV3000L6E 63,517 BDVS3000L6E 66, /3/60 Standard See Note 2 High Efficiency s: High Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) BLV1501H6C 42,347 BDVS1501H6C 45, /3/60 High Efficiency See Note 1 BLV1501H6D 43,105 BDVS1501H6D 45, /3/60 High Efficiency See Note 1 BLV1501H6E 43,968 BDVS1501H6E 46, /3/60 High Efficiency See Note 1 BLV2001H6C 44,644 BDVS2001H6C 47, /3/60 High Efficiency See Note 1 BLV2001H6D 45,403 BDVS2001H6D 48, /3/60 High Efficiency See Note 1 BLV2001H6E 46,312 BDVS2001H6E 49, /3/60 High Efficiency See Note 1 BLV2501H6C 62,910 BDVS2501H6C 66, /3/60 High Efficiency See Note 1 BLV2501H6D 63,738 BDVS2501H6D 66, /3/60 High Efficiency See Note 1 BLV2501H6E 65,011 BDVS2501H6E 68, /3/60 High Efficiency See Note 1 BLV3001H6C 65,654 BDVS3001H6C 68, /3/60 High Efficiency See Note 1 BLV3001H6D 66,413 BDVS3001H6D 69, /3/60 High Efficiency See Note 1 BLV3001H6E 67,740 BDVS3001H6E 70, /3/60 High Efficiency See Note 1 BLV3501H6C 82,094 BDVS3501H6C 85, /3/60 High Efficiency See Note 1 BLV3501H6D 82,850 BDVS3501H6D 86, /3/60 High Efficiency See Note 1 BLV3501H6E 84,508 BDVS3501H6E 88, /3/60 High Efficiency See Note 1 BLV4001H6D 83,770 BDVS4001H6D 87, /3/60 High Efficiency See Note 1 BLV4001H6E 85,445 BDVS4001H6E 88, /3/60 High Efficiency See Note 1 High Efficiency s: Low Temperature (R-404A/507, R-407A/R-407F, R407C, and R-448A/R-449A) BLV1201L6C 40,980 BDVS1201L6C 43, /3/60 High Efficiency See Note 1, 2 BLV1201L6D 41,739 BDVS1201L6D 44, /3/60 High Efficiency See Note 1, 2 BLV1201L6E 42,574 BDVS1201L6E 45, /3/60 High Efficiency See Note 1, 2 BLV1501L6C 44,033 BDVS1501L6C 46, /3/60 High Efficiency See Note 1, 2 BLV1501L6D 44,790 BDVS1501L6D 47, /3/60 High Efficiency See Note 1, 2 BLV1501L6E 45,684 BDVS1501L6E 48, /3/60 High Efficiency See Note 1, 2 BLV2201L6C 51,262 BDVS2201L6C 54, /3/60 High Efficiency See Note 1, 2 BLV2201L6D 52,021 BDVS2201L6D 54, /3/60 High Efficiency See Note 1, 2 BLV2201L6E 53,061 BDVS2201L6E 55, /3/60 High Efficiency See Note 1, 2 Section 2 Rev. 01/18 Notes: 1. High Efficiency s come with an oversized condenser. 2. For R-407A/R-407F, R407C, and R-448A/R-449A low temperature operation, add Demand Cooling Kit. s Effective January 1 st s and specifications subject to change without notice. 141

147 Air-Cooled Condensing Units HP Vertical Air Discharge Configurable s Pricing Section 2 Outdoor Beacon II Outdoor Voltage Type Notes BLV2701L6C 61,625 BDVS2701L6C 64, /3/60 High Efficiency See Note 1, 2 BLV2701L6D 62,380 BDVS2701L6D 65, /3/60 High Efficiency See Note 1, 2 BLV2701L6E 63,628 BDVS2701L6E 66, /3/60 High Efficiency See Note 1, 2 BLV3001L6C 65,048 BDVS3001L6C 68, /3/60 High Efficiency See Note 1, 2 BLV3001L6D 65,805 BDVS3001L6D 68, /3/60 High Efficiency See Note 1, 2 BLV3001L6E 67,123 BDVS3001L6E 70, /3/60 High Efficiency See Note 1, 2 BLV1201L6C 40,980 BDVS1201L6C 43, /3/60 High Efficiency See Note 1, 2 BLV1201L6D 41,739 BDVS1201L6D 44, /3/60 High Efficiency See Note 1, 2 BLV1201L6E 42,574 BDVS1201L6E 45, /3/60 High Efficiency See Note 1, 2 BLV1501L6C 44,033 BDVS1501L6C 46, /3/60 High Efficiency See Note 1, 2 BLV1501L6D 44,790 BDVS1501L6D 47, /3/60 High Efficiency See Note 1, 2 BLV1501L6E 45,684 BDVS1501L6E 48, /3/60 High Efficiency See Note 1, 2 BLV2201L6C 51,262 BDVS2201L6C 54, /3/60 High Efficiency See Note 1, 2 BLV2201L6D 52,021 BDVS2201L6D 54, /3/60 High Efficiency See Note 1, 2 BLV2201L6E 53,061 BDVS2201L6E 55, /3/60 High Efficiency See Note 1, 2 BLV2701L6C 61,625 BDVS2701L6C 64, /3/60 High Efficiency See Note 1, 2 BLV2701L6D 62,380 BDVS2701L6D 65, /3/60 High Efficiency See Note 1, 2 BLV2701L6E 63,628 BDVS2701L6E 66, /3/60 High Efficiency See Note 1, 2 BLV3001L6C 65,048 BDVS3001L6C 68, /3/60 High Efficiency See Note 1, 2 BLV3001L6D 65,805 BDVS3001L6D 68, /3/60 High Efficiency See Note 1, 2 BLV3001L6E 67,123 BDVS3001L6E 70, /3/60 High Efficiency See Note 1, 2 Notes: 1. High Efficiency s come with an oversized condenser. 2. For R-407A/R-407F, R407C, and R-448A/R-449A low temperature operation, add Demand Cooling Kit. 142 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

148 Air-Cooled Condensing Units HP Vertical Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes DFT.001 Defrost Timer - Air All FCY FCY Fan Cycling - Temperature Fan Cycling - Temperature Standard s High Efficiency s Standard s High Efficiency s Medium temperature applications only. Adder Outdoor Beacon II Outdoor Fan closest to the header is not cycled. 1,785 - Fan closest to the header is not cycled. 2,126 - FCY Fan Cycling - Temperature High Efficiency s Fan closest to the header is not cycled. 2,423 - FCY FCY Fan Cycling - Pressure Fan Cycling - Pressure Standard s High Efficiency s Standard s High Efficiency s Fan closest to the header is not cycled. 1,785 Standard Fan closest to the header is not cycled. 2,126 Standard FCY Fan Cycling - Pressure High Efficiency s Fan closest to the header is not cycled. 2,423 Standard FSD Fused Disconnect (230V) - 1,698 1,698 FSD Fused Disconnect (460V) - 2,474 2,474 FSD Fused Disconnect (460V) - 3,603 3,603 NFD Non-Fused Disconnect (230V) - 1,593 1,593 NFD Non-Fused Disconnect (460V) - 2,294 2,294 NFD Non-Fused Disconnect (460V) - 3,356 3,356 CBK Compressor Circuit Breaker 230V - 2,635 2,635 CBK Compressor Circuit Breaker 460V - 1,224 1,224 PLM.00X Phase Loss Monitor 230V & 460V - 1,153 1,153 TDR.002 Anti-short Cycling Timer All HPS.001 MS.0012D Manual Reset High Pressure Switch Variable Speed EC Motor with proportional pressure controller All M6 Standard s (230V & 460V) L6 Standard s (230V & 460V) 1201L6-2201L6 High Efficiency s (230V & 460V) - 15,698 15,698 Section 2 Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 143

149 Air-Cooled Condensing Units HP Vertical Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code MS.0012L MS.0013L MS.0014L Mechanical Options LIQ LIQ Description s Used On Notes Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Replaceable core liquid-line filter drier & sight glass Replaceable core liquid-line filter drier & sight glass M6 Standard s (230V & 460V) L6 Standard s (230V & 460V) 1201L6-2201L6 High Efficiency s (230V & 460V) M6 Standard s (230V & 460V) H6 High Efficiency s (230V & 460V) H6 High Efficiency s (230V & 460V) LIQ Liquid-line solenoid valve LIQ Liquid-line solenoid valve Adder Outdoor Beacon II Outdoor - 19,107 19,107-27,572 27,572-38,211 38, Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet ,026 - SUC Suction-line filter ,290 1,290 SUC Suction-line filter ,652 1,652 SUC SUC Replaceable core suctionline filter Replaceable core suctionline filter ,687 1, ,762 1,762 SUC Suction accumulator ,755 2,755 SUC Suction accumulator ,161 3,161 DIS DIS Oil separator with discharge line check valve Oil separator with discharge line check valve ,652 1, ,792 2,792 MUF.001 Discharge muffler All Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

150 Air-Cooled Condensing Units HP Vertical Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code DIS DIS UNL.001 DMD.001 REC REC Coil Options CS.PRO-1 CS.PRO-2 CS.PRO-3 CS.PRO-4 CS.ELEC-1 Description s Used On Notes Three way heat reclam valve with check valve installed Three way heat reclam valve with check valve installed Compressor Unloading - with pressure control for (1) cyl. Bank Demand Cooling for low temperature R-407A/R-407F, R-407C, and R-448A/R-449A Low Ambient kit with heated and insulated receiver and time delay relay Low Ambient kit with heated and insulated receiver and time delay relay Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection ElectroFin coil coating Adder Outdoor Beacon II Outdoor ,706 1, ,499 2,499 All - 1, L6-2,390 2, ,609 2, ,428 3, Standard s High Efficiency s - 2,007 2, High Efficiency s - 2,521 2, Standard s - 2,570 2, High Efficiency s - 3,603 3, Standard s High Efficiency s - Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating High Efficiency s - Call Factory Call Factory CS.ELEC-3 ElectroFin coil coating Standard s - Call Factory Call Factory CS.ELEC-4 ElectroFin coil coating High Efficiency s - Call Factory Call Factory CS.CPR-1 Copper condenser fins Standard s High Efficiency s - Call Factory Call Factory CS.CPR-2 Copper condenser fins High Efficiency s - Call Factory Call Factory CS.CPR-3 Copper condenser fins Standard s - Call Factory Call Factory CS.CPR-4 Copper condenser fins High Efficiency s - Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating Standard s High Efficiency s - Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating High Efficiency s - Call Factory Call Factory CS.BRZ-3 Bronz-Glow coil coating Standard s - Call Factory Call Factory CS.BRZ-4 Bronz-Glow coil coating High Efficiency s - Call Factory Call Factory Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 145

151 Air-Cooled Condensing Units HP Vertical Air Discharge Factory-Installed Electric Defrost Options Section 2 Selecting the proper kit is as easy as 12 3 Need an electric defrost kit? Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, contact your local Sales Representative or Account Engineer to find out the rated defrost power amps for both the fan motor amps and electric heater amps. The condensing unit data plate ratings are based on the actual system match. Your local Sales Representative or Account Engineer will help you select the proper electric defrost kit and components. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Option Code DFT.014 DFT.015 DFT.011 DFT.012 DFT.009 DFT.010 Description s Used On Notes Electric Defrost Kit for system with one evaporator - Low Amps (1L) Electric Defrost Kit for system with one evaporator - Low Amps (1H) Electric Defrost Kit for system with two evaporators - Low Amps (2L) Electric Defrost Kit for system with two evaporators - High Amps (2H) Electric Defrost Kit for system with up to four evaporators - Low Amps (4L) Electric Defrost Kit for system with up to four evaporators - High Amps (4H) L6 (230V) M6 (460V & 575V) L6 (460V & 575V) L6 (230V) M6 (460V & 575V) L6 (460V & 575V) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) M6 (all voltages) L6 (all voltages) M6 (all voltages) L6 (all voltages) Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (4) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (4) heater & (1) fan contactors, terminal strip Adder Outdoor 1,830 1,830 2,635 2,635 3,436 3, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

152 Air-Cooled Condensing Units HP Vertical Air Discharge Factory-Installed Electric Defrost Options Option Code DEF.017 DEF.039 DEF.052 EHR.001 EHR.002 EHR.003 Description s Used On Notes Fuses for electric defrost kits (1L/1H) Fuses for electric defrost kits (2L/2H) Fuses for electric defrost kits (4L/4H) Evaporator hold out relays - 2 Evaps & 2 Contactors (2L/2H) Evaporator hold out relays - 2 Evaps & 4 Contactors (4L/4H) Evaporator hold out relays - 4 Evaps & 4 Contactors (4L/4H) L6 (230V) M6 (460V & 575V) L6 (460V & 575V) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) M6 (all voltages) L6 (all voltages) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) M6 (230V) M6 (460V & 575V) L6 (230V, 460V, 575V) SDK.001 InterLink Smart Defrost Kit All Adder Outdoor For systems with one evaporator 459 For systems with two evaporators 916 For systems with up to four evaporators For use with 2L/2H Electric Defrost Kits with two evaporators For use with 4L/4H Electric Defrost Kits with only two evaporators For use with 4L/4H Electric Defrost Kits with four evaporators Can not be used alone. Must also select a electric defrost timer or electric defrost kit. 1, HP Vertical Air Discharge Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 7/8" /8" /8" 4227W 1, /8" 4262Q 2, /8" ,060 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 147

153 Air-Cooled Condensing Units HP Vertical Air Discharge Overview Section 2 Product Description The HP condensing unit product line with Bitzer compressors is designed to meet the needs of a demanding commercial and industrial refrigeration market. The product is configured to be flexible in its design and construction to allow it to respond to the requirements of refrigeration contractors, consulting engineers and facility owners/operators. The Floating Tube coil design incorporated in the product provides protection against tube sheet leaks. Opting for the Beacon II refrigeration system with Smart Defrost, Factory installed Defrost Kit (SDK) or Variable Speed EC motors increases this product s energy efficiency and quailifies it for the E Solutions product portfolio Cabinet & Construction All units feature the Floating Tube coil which eliminates tube sheet leaks Painted steel cabinets for superior strength and corrosion resistance Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Large electrical panel to facilitate ease of access Quality Sight glass is easily viewable Fixed high pressure switch eliminates capillary tubes Refrigeration duty, rifled copper tubing Piping is pre-bent to eliminate braze joints, where possible, to reduce leak potential All joints are sweat type connections, no mechanical joints to leak Separate sub-cooling circuit in condenser for added capacity and vapor free liquid Pressure relief valve on receiver ServiceMate diagnostic module standard on all non-beacon condensing units Components Compressor Units feature Bitzer semi-hermetic compressors. Available with compressor unloading Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves Other Sight glass and permanent liquid line filter Certifications Nomenclature 148 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

154 Air-Cooled Condensing Units HP Vertical Air Discharge Configurable s Pricing Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Adjustable flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose Crankcase heater ServiceMate Diagnostic Module Configurable s Need to customize? Look at the factory-installed options starting on page 150. Beacon II Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Adjustable flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose Crankcase heater Wired for Beacon II control with fan cycling. Outdoor Beacon II Outdoor Voltage Medium Temperature R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A BLV150BM6C 38,290 BDVS150BM6C 40, /3/60 BLV150BM6D 38,748 BDVS150BM6D 40, /3/60 BLV150BM6E 39,515 BDVS150BM6E 41, /3/60 BLV200BM6C 44,644 BDVS200BM6C 46, /3/60 BLV200BM6D 45,179 BDVS200BM6D 47, /3/60 BLV200BM6E 46,072 BDVS200BM6E 48, /3/60 BLV220BM6C 50,836 BDVS220BM6C 53, /3/60 BLV220BM6D 51,447 BDVS220BM6D 53, /3/60 BLV220BM6E 52,463 BDVS220BM6E 55, /3/60 BLV250BM6C 57,097 BDVS250BM6C 59, /3/60 BLV250BM6D 57,782 BDVS250BM6D 60, /3/60 BLV250BM6E 58,924 BDVS250BM6E 61, /3/60 BLV300BM6C 60,250 BDVS300BM6C 63, /3/60 BLV300BM6D 60,973 BDVS300BM6D 63, /3/60 BLV300BM6E 62,178 BDVS300BM6E 65, /3/60 BLV330BM6C 67,488 BDVS330BM6C 70, /3/60 BLV330BM6D 68,298 BDVS330BM6D 71, /3/60 BLV330BM6E 69,649 BDVS330BM6E 73, /3/60 BLV350BM6C 75,474 BDVS350BM6C 79, /3/60 BLV350BM6D 76,379 BDVS350BM6D 80, /3/60 BLV350BM6E 77,888 BDVS350BM6E 81, /3/60 BLV400BM6C 83,003 BDVS400BM6C 87, /3/60 BLV400BM6D 84,001 BDVS400BM6D 88, /3/60 BLV400BM6E 85,659 BDVS400BM6E 89, /3/60 Outdoor Beacon II Outdoor Voltage BLV500BM6C 95,465 BDVS500BM6C 100, /3/60 BLV500BM6D 96,611 BDVS500BM6D 101, /3/60 BLV500BM6E 98,519 BDVS500BM6E 103, /3/60 Low Temperature R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A BLV130BL6C 39,600 BDVS130BL6C 41, /3/60 BLV130BL6D 40,154 BDVS130BL6D 42, /3/60 BLV130BL6E 40,947 BDVS130BL6E 43, /3/60 BLV150BL6C 44,033 BDVS150BL6C 46, /3/60 BLV150BL6D 44,649 BDVS150BL6D 47, /3/60 BLV150BL6E 45,530 BDVS150BL6E 47, /3/60 BLV200BL6C 51,262 BDVS200BL6C 53, /3/60 BLV200BL6D 51,980 BDVS200BL6D 54, /3/60 BLV200BL6E 53,005 BDVS200BL6E 55, /3/60 BLV220BL6C 55,542 BDVS220BL6C 58, /3/60 BLV220BL6D 56,318 BDVS220BL6D 59, /3/60 BLV220BL6E 57,430 BDVS220BL6E 60, /3/60 BLV250BL6C 61,625 BDVS250BL6C 64, /3/60 BLV250BL6D 62,488 BDVS250BL6D 65, /3/60 BLV250BL6E 63,721 BDVS250BL6E 67, /3/60 BLV300BL6C 65,048 BDVS300BL6C 68, /3/60 BLV300BL6D 65,957 BDVS300BL6D 69, /3/60 BLV300BL6E 67,259 BDVS300BL6E 70, /3/60 BLV400BL6C 75,474 BDVS400BL6C 79, /3/60 BLV400BL6D 76,529 BDVS400BL6D 80, /3/60 BLV400BL6E 78,038 BDVS400BL6E 82, /3/60 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 149

155 Air-Cooled Condensing Units HP Vertical Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code Electrical Options Description s Used On Notes Adder Outdoor DFT.001 Defrost Timer - Air All M6 Medium temperature applications only FCY Fan Cycling - Temperature 130B-250B Fan closest to the header is not cycled. 1,785 - FCY Fan Cycling - Temperature 300B-350B Fan closest to the header is not cycled. 2,126 - FCY Fan Cycling - Temperature 400B-500B Fan closest to the header is not cycled. 2,423 - Beacon II Outdoor FCY Fan Cycling - Pressure 130B-250B Fan closest to the header is not cycled. 1,785 Press. Std. FCY Fan Cycling - Pressure 300B-350B Fan closest to the header is not cycled. 2,126 Press. Std. FCY Fan Cycling - Pressure 400B-500B Fan closest to the header is not cycled. 2,423 Press. Std. FSD Fused Disconnect 130B-220B (230V) - 1,698 1,698 FSD Fused Disconnect 130B-250B (460V) 300B only (230V) - 2,474 2,474 FSD Fused Disconnect 300B-400B (460V) - 3,603 3,603 NFD Non-Fused Disconnect 130B-250B (230V) - 1,593 1,593 NFD Non-Fused Disconnect 130B-250B (460V) 300B only (230V) - 2,294 2,294 NFD Non-Fused Disconnect 300B-400B (460V) - 3,356 3,356 CBK Compressor Circuit Breaker 230V - 2,635 2,635 CBK Compressor Circuit Breaker 460V - 1,224 1,224 PLM.00X Phase Loss Monitor All - 1,153 1,153 TDR.002 Anti-short Cycling Timer All HPS.001 Manual Reset High Pressure Switch All MS.0012D MS.0012L MS.0013L MS.0014L Mechanical Options LIQ LIQ Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Replaceable core liquid-line filter drier & sight glass Replaceable core liquid-line filter drier & sight glass 150BM6 (230V & 460V) 130B-200BL6 (230V & 460V) 200B-250BM6 (230V & 460V) 220B-300BL6 (230V & 460V) 300B-350BM6 (230V & 460V) 400BL6 (230V & 460V) - 15,698 15,698-19,107 19,107-27,572 27, B-500BM6 (230V & 460V) - 36,038 36, B-220B B-400B Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. 150 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

156 Air-Cooled Condensing Units HP Vertical Air Discharge Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code LIQ Description s Used On Notes Replaceable core liquid-line filter drier & sight glass LIQ Liquid-line solenoid valve 130B-220B LIQ Liquid-line solenoid valve 250B-400B LIQ Liquid-line solenoid valve 500B Adder Outdoor Beacon II Outdoor 500B Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet ,026-1,232 - SUC Suction-line filter 130B-220B - 1,290 1,290 SUC Suction-line filter 250B-400B - 1,652 1,652 SUC Suction-line filter 500B - 2,066 2,066 SUC Replaceable core suction-line filter 130B-220B - 1,687 1,687 SUC Replaceable core suction-line filter 250B-400B - 1,762 1,762 SUC Replaceable core suction-line filter 500B - 2,204 2,204 SUC Suction accumulator 130B-220B - 2,755 2,755 SUC Suction accumulator 250B-400B - 3,161 3,161 SUC Suction accumulator 500B - 4,108 4,108 DIS DIS DIS Oil separator with discharge line check valve Oil separator with discharge line check valve Oil separator with discharge line check valve 130B-330B - 1,652 1, B-400B - 2,792 2, B - 3,352 3,352 MUF.001 Discharge muffler All DIS DIS DIS UNL.001 REC REC Coil Options Three way heat reclam valve with check valve installed Three way heat reclam valve with check valve installed Three way heat reclam valve with check valve installed Compressor Unloading - with pressure control for (1) cyl. Bank Low Ambient kit with heated and insulated receiver and time delay relay Low Ambient kit with heated and insulated receiver and time delay relay 130B-200B - 1,706 1, B-400B - 2,499 2, B - 2,999 2,999 All - 1, B-330B - 2,609 2, B-500B - 3,428 3,428 CS.PRO-1 Guard condenser fin protection 130B-330B - 2,007 2,007 CS.PRO-2 Guard condenser fin protection 350B-500B - 2,570 2,570 CS.ELEC-1 ElectroFin coil coating 130B-330B - Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating 350B-500B - Call Factory Call Factory CS.CPR-1 Copper condenser fins 130B-330B - Call Factory Call Factory CS.CPR-2 Copper condenser fins 350B-500B - Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating 130B-300B - Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating 330B-500B - Call Factory Call Factory Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 151

157 Air-Cooled Condensing Units HP Vertical Air Discharge Factory-Installed Electric Defrost Options Section 2 Need an electric defrost kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, contact your local Sales Representative or Account Engineer to find out the rated defrost power amps for both the fan motor amps and electric heater amps. The condensing unit data plate ratings are based on the actual system match. Your local Sales Representative or Account Engineer will help you select the proper electric defrost kit and components. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Option Code DFT.00X1 DFT.00X2 DFT.00X4 SDK.001 Description s Used On Notes Electric Defrost Kit for system with one evaporator Electric Defrost Kit for system with two evaporators Electric Defrost Kit for system with four evaporators InterLink Smart Defrost Kit All s 230 and 460V All s 230 and 460V All s 230 and 460V All Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (4) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Can not be used alone. Must also select a electric defrost timer or electric defrost kit. Adder Outdoor 2,290 3,904 5, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

158 Air-Cooled Condensing Units HP Vertical Air Discharge Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 7/8" /8" /8" 4227W 1, /8" 4262Q 2, /8" ,060 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 153

159 Air-Cooled Condensing Units HP Dual Compressor Overview Section 2 Product Description: The HP Dual Vertical condensing unit is designed to meet the needs of a demanding commercial and industrial refrigeration market. The product is configured to be flexible in its design and construction to allow it to respond to the requirements of refrigeration contractors, consulting engineers and facility owners/operators. The Floating Tube coil design incorporated in the product provides protection against tube sheet leaks. Opting for the Beacon II refrigeration system with Smart Defrost, factory installed Smart Defrost Kit (SDK) or Variable Speed EC motors increases this product s energy efficiency and qualifies it for the E Solutions product portfolio. Cabinet & Construction All units feature the Floating Tube coil which eliminates tube sheet leaks Painted steel cabinets for superior strength and corrosion resistance Available in standard or parallel piped configurations Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Large electrical panel to facilitate ease of access Quality Sight glass is easily viewable Fixed high pressure switch eliminates capillary tubes Refrigeration duty, rifled copper tubing Piping is pre-bent to eliminate braze joints, where possible, to reduce leak potential All joints are sweat type connections, no mechanical joints to leak Separate sub-cooling circuit in condenser for added capacity and vapor free liquid Pressure relief valve on receiver ServiceMate diagnostic module standard on all non-beacon II condensing unit Components Compressor Spring-mounted compressors with suction and discharge eliminators Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves Other Sight glass and permanent liquid line filter Certifications Nomenclature 154 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

160 Air-Cooled Condensing Units HP Dual Compressor Configurable s Pricing Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Parallel-piped units include replaceable core suction filter, replaceable liquid-line filter, suction accumulator, and oil management system. Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose ServiceMate Diagnostic Module Configurable s Need to customize? Look at the factory-installed options starting on page 157. Beacon II Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose Wired for Beacon II control with fan cycling. Outdoor Beacon II Outdoor Voltage Type Notes Individually Piped s: Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD3000M6C 76,581 JDDS3000M6C 80, /3/60 Individually Piped - JLD3000M6D 78,096 JDDS3000M6D 81, /3/60 Individually Piped - JLD4000M6C 85,217 JDDS4000M6C 88, /3/60 Individually Piped - JLD4000M6D 86,725 JDDS4000M6D 90, /3/60 Individually Piped - JLD5000M6C 101,669 JDDS5000M6C 105, /3/60 Individually Piped - JLD5000M6D 103,187 JDDS5000M6D 106, /3/60 Individually Piped - JLD5200M6C 114,193 JDDS5200M6C 117, /3/60 Individually Piped - JLD5200M6D 115,705 JDDS5200M6D 119, /3/60 Individually Piped - JLD6000M6C 119,243 JDDS6000M6C 122, /3/60 Individually Piped - JLD6000M6D 120,759 JDDS6000M6D 124, /3/60 Individually Piped - JLD7000M6C 134,978 JDDS7000M6C 138, /3/60 Individually Piped - JLD7000M6D 136,219 JDDS7000M6D 139, /3/60 Individually Piped - JLD8000M6D 150,942 JDDS8000M6D 154, /3/60 Individually Piped - JLD8000M6K 148,923 JDDS8000M6K 152, /3/60 Individually Piped - Individually Piped s: Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD2400L6C 78,520 JDDS2400L6C 81, /3/60 Individually Piped See Note 1, 2 JLD2400L6D 80,046 JDDS2400L6D 83, /3/60 Individually Piped See Note 1, 2 JLD3000L6C 82,197 JDDS3000L6C 85, /3/60 Individually Piped See Note 1, 2 JLD3000L6D 83,709 JDDS3000L6D 87, /3/60 Individually Piped See Note 1, 2 JLD4400L6C 96,471 JDDS4400L6C 99, /3/60 Individually Piped See Note 1, 2 JLD4400L6D 97,986 JDDS4400L6D 101, /3/60 Individually Piped See Note 1, 2 JLD5400L6C 110,879 JDDS5400L6C 114, /3/60 Individually Piped See Note 1, 2 JLD5400L6D 112,395 JDDS5400L6D 115, /3/60 Individually Piped See Note 1, 2 JLD6000L6C 123,024 JDDS6000L6C 126, /3/60 Individually Piped See Note 1, 2 JLD6000L6D 124,540 JDDS6000L6D 127, /3/60 Individually Piped See Note 1, 2 Section 2 Rev. 01/18 Notes: 1. L6 models include head cooling fan. 2. For R-407A/R-407F, R-407C, and R-448A/R-449A low temperature operation, add Demand Cooling Kit. s Effective January 1 st s and specifications subject to change without notice. 155

161 Air-Cooled Condensing Units HP Dual Compressor Configurable s Pricing Section 2 Outdoor Beacon II Outdoor Voltage Type Notes Parallel-Piped s: Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD3000M6CPP 96, /3/60 Parallel Piped - JLD3000M6DPP 97, /3/60 Parallel Piped - JLD4000M6CPP 104, /3/60 Parallel Piped - JLD4000M6DPP 105, /3/60 Parallel Piped - JLD5000M6CPP 120, /3/60 Parallel Piped - JLD5000M6DPP 122, /3/60 Parallel Piped - JLD5200M6CPP 132, /3/60 Parallel Piped - JLD5200M6DPP 134, /3/60 Parallel Piped - JLD6000M6CPP 137, /3/60 Parallel Piped - JLD6000M6DPP 138, /3/60 Parallel Piped - JLD7000M6CPP 153, /3/60 Parallel Piped - JLD7000M6DPP 154, /3/60 Parallel Piped - JLD8000M6DPP 168, /3/60 Parallel Piped - JLD8000M6KPP 166, /3/60 Parallel Piped - Parallel-Piped s: Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD2400L6CPP 97, /3/60 Parallel Piped See Note 1, 2 JLD2400L6DPP 99, /3/60 Parallel Piped See Note 1, 2 JLD3000L6CPP 101, /3/60 Parallel Piped See Note 1, 2 JLD3000L6DPP 102, /3/60 Parallel Piped See Note 1, 2 JLD4400L6CPP 115, /3/60 Parallel Piped See Note 1, 2 JLD4400L6DPP 117, /3/60 Parallel Piped See Note 1, 2 JLD5400L6CPP 129, /3/60 Parallel Piped See Note 1, 2 JLD5400L6DPP 131, /3/60 Parallel Piped See Note 1, 2 JLD6000L6CPP 140, /3/60 Parallel Piped See Note 1, 2 JLD6000L6DPP 142, /3/60 Parallel Piped See Note 1, 2 Notes: 1. L6 models include head cooling fan. 2. For R-407A/R-407F, R-407C, and R-448A/R-449A low temperature operation, add Demand Cooling Kit. 156 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

162 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes Adder Beacon II Outdoor Outdoor DFT.001 Defrost Timers - Air All - Individually Piped Medium temperature applications only. 1,123 - DFT.001P Defrost Timers - Air All - Parallel Piped Medium temperature applications only FCY Fan Cycling - Temperature Individually Piped Fan closest to the header is not cycled. 3,569 - FCY.001-1P Fan Cycling - Temperature Parallel Piped Fan closest to the header is not cycled. 2,888 - FCY Fan Cycling - Temperature Individually Piped Fan closest to the header is not cycled. 4,250 - FCY.001-2P Fan Cycling - Temperature Parallel Piped Fan closest to the header is not cycled. 3,569 - FCY Fan Cycling - Pressure Individually Piped Fan closest to the header is not cycled. 3,569 Standard FCY.002-1P Fan Cycling - Pressure Parallel Piped Fan closest to the header is not cycled. 2,888 - FCY Fan Cycling - Pressure Individually Piped Fan closest to the header is not cycled. 4,250 Standard FCY.002-2P Fan Cycling - Pressure Parallel Piped Fan closest to the header is not cycled. 3,569 - CBK Compressor Circuit Breakers 230V - Individually Piped CBK.002-2P Compressor Circuit Breakers 230V - Parallel Piped CBK Compressor Circuit Breakers 460V - Individually Piped CBK.002-1P Compressor Circuit Breakers 460V - Parallel Piped No CBK options are available for the 8000 units. No CBK options are available for the 8000 units. No CBK options are available for the 8000 units. No CBK options are available for the 8000 units. 5,273 5,273 5,273-2,451 2,451 2,451 - PLM.00X Phase Loss Monitors 230V & 460V - Individually Piped - 1,153 1,153 PLM.00XP Phase Loss Monitors 230V & 460V - Parallel Piped - 1,153 - TDR.002 Anti-short Cycling Timers All - Individually Piped - 1,329 1,329 TDR.002P Anti-short Cycling Timers All - Parallel Piped HPS.001 HPS.001P MS.0014S-1 MS.0014S-2 MS.0014L-1 MS.0014L-2 Manual Reset High Pressure Switches Manual Reset High Pressure Switches Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller All - Individually Piped All - Parallel Piped M6 Parallel Piped (230V & 460V) L6 Parallel Piped (230V & 460V) M6 Individually Piped (230V & 460V) L6 Individually Piped (230V & 460V) M6 Parallel Piped (230V & 460V) 6000L6 Parallel Piped (230V & 460V) M6 Individually Piped (230V & 460V) 6000L6 Individually Piped (230V & 460V) - 24, ,849 26,849-36, ,211 38,211 Section 2 Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 157

163 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code MS.0016L-1 MS.0016L-2 Mechanical Options LIQ LIQ.003-1P LIQ LIQ.003-2P Description s Used On Notes Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses M6 Parallel Piped (230V & 460V) M6 Individually Piped (230V & 460V) LIQ Liquid-line solenoid valves Individually Piped LIQ.002-1P Liquid-line solenoid valves Parallel Piped LIQ Liquid-line solenoid valves Individually Piped LIQ.002-2P Liquid-line solenoid valves Parallel Piped Adder Beacon II Outdoor Outdoor - 52, ,142 55, Individually Piped Parallel Piped - Standard Individually Piped - 1,394 1, Parallel Piped - Standard - Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. 1,913-1,026-2,052-1,383 - SUC Suction-line filters Individually Piped - 2,578 2,578 SUC.003-1P Suction-line filters Parallel Piped - N/A - SUC Suction-line filters Individually Piped - 3,302 3,302 SUC.003-2P Suction-line filters Parallel Piped - N/A - SUC SUC.005-1P SUC SUC.005-2P Replaceable core suction-line filters Replaceable core suction-line filters Replaceable core suction-line filters Replaceable core suction-line filters Individually Piped - 3,376 3, Parallel Piped - Standard Individually Piped - 3,420 3, Parallel Piped - Standard - SUC Suction accumulators Individually Piped - 5,511 5,511 SUC.007-1P Suction accumulators Parallel Piped - Standard - SUC Suction accumulators Individually Piped - 6,320 6,320 SUC.007-2P Suction accumulators Parallel Piped - Standard - DIS DIS.001-1P DIS DIS.001-2P Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves Individually Piped - 3,302 3, Parallel Piped - Standard Individually Piped - 5,585 5, Parallel Piped - Standard - MUF.001 Discharge mufflers All - Individually Piped MUF.001P Discharge mufflers All - Parallel Piped - N/A s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

164 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Rev. 01/18 Option Code DIS DIS.002-1P DIS DIS.002-2P DIS DIS.002-3P UNL.001 UNL.001P DMD.001 DMD.001P REC REC.001-1P REC REC.001-2P Coil Options CSG.PRO-1 CSG.PRO-2 CSG.PRO-3 Description s Used On Notes Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Compressor Unloading - with pressure control for (1) cyl. Bank Compressor Unloading - with pressure control for (1) cyl. Bank Demand Cooling for low temperature R-407A/R-407F, R-407C, and R-448A/R-449A Demand Cooling for low temperature R-407A/R-407F, R-407C, and R-448A/R-449A Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection s Effective January 1 st s and specifications subject to change without notice. Adder Beacon II Outdoor Outdoor Individually Piped - 4,997 4, Parallel Piped - Call Factory Individually Piped - 6,510 6, Parallel Piped - Call Factory Individually Piped - 9,429 9, Parallel Piped - Call Factory - All - Individually Piped - 3,392 - All - Parallel Piped - 3, L6 Individually Piped - 4,779 4, L6 Parallel Piped - 4, Individually Piped - 5,218 5, Parallel Piped - 5, Individually Piped - 6,855 6, Parallel Piped - 6, ,354 3, ,585 5, ,259 6,259 CS.ELEC-1 ElectroFin coil coating Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating Call Factory Call Factory CS.ELEC-3 ElectroFin coil coating Call Factory Call Factory CSB.CPR-1 Copper condenser fins Call Factory Call Factory CSB.CPR-2 Copper condenser fins Call Factory Call Factory CSB.CPR-3 Copper condenser fins Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating Call Factory Call Factory CS.BRZ-3 Bronz-Glow coil coating Call Factory Call Factory 159 Section 2

165 Air-Cooled Condensing Units HP Dual Compressor Factory-Installed Electric Defrost Options Section 2 Need an electric defrost kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, contact your local Sales Representative or Account Engineer to find out the rated defrost power amps for both the fan motor amps and electric heater amps. The condensing unit data plate ratings are based on the actual system match. Your local Sales Representative or Account Engineer will help you select the proper electric defrost kit and components. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity 160 Option Code DFT.016 DFT.016P DFT.013 DFT.013P DEF.XXX1 DEF.XXX1P DEF.XXX2 DEF.XXX2P Description s Used On Notes Electric Defrost Kit for system with one evaporator per compressor circuit Electric Defrost Kit for system with one evaporator per compressor circuit Electric Defrost Kit for system with two evaporators per compressor circuit Electric Defrost Kit for system with two evaporators per compressor circuit Fuses for electric defrost kit for system with one evaporator per compressor circuit Fuses for electric defrost kit for system with one evaporator per compressor circuit Fuses for electric defrost kit for system with two evaporators per compressor circuit Fuses for electric defrost kit for system with two evaporators per compressor circuit M6 (230V) Individually Piped L6 (230V) Individually Piped (460V) Individually Piped M6 (230V) Parallel Piped L6 (230V) Parallel Piped (460V) Parallel Piped M6 (230V) Individually Piped L6 (230V) Individually Piped (460V) Individually Piped M6 (230V) Parallel Piped L6 (230V) Parallel Piped (460V) Parallel Piped M6 (230V) Individually Piped L6 (230V) Individually Piped (460V) Individually Piped M6 (230V) Parallel Piped L6 (230V) Parallel Piped (460V) Parallel Piped M6 (230V) Individually Piped L6 (230V) Individually Piped (460V) Individually Piped M6 (230V) Parallel Piped L6 (230V) Parallel Piped (460V) Parallel Piped SDK.001 InterLink Smart Defrost Kit All - Individually Piped SDK.001P InterLink Smart Defrost Kit All - Parallel Piped Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip Adder Outdoor s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18 3,661 3,099 5,273 4, ,831-1,831 Can not be used alone. Must also select a electric defrost timer or electric defrost kit. Can not be used alone. Must also select a electric defrost timer or electric defrost kit. 1,739 N/A

166 Air-Cooled Condensing Units HP Dual Compressor Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Must have one valve per compressor. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 7/8" /8" /8" 4227W 1, /8" 4262Q 2, /8" , /8" ,926 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 161

167 Air-Cooled Condensing Units HP Dual Compressor Overview Section 2 Product Description: The HP Dual Vertical condensing unit product line with Bitzer compressors is designed to meet the needs of a demanding commercial and industrial refrigeration market. The product is configured to be flexible in its design and construction to allow it to respond to the requirements of refrigeration contractors, consulting engineers and facility owners/operators. The Floating Tube coil design incorporated in the product provides protection against tube sheet leaks. Opting for the Beacon II refrigeration system Smart Defrost, factory installed Smart Defrost Kit (SDK) or Variable Speed EC motors increases this product s energy efficiency and qualifies it for the E Solutions product portfolio. Cabinet & Construction All units feature the Floating Tube coil which eliminates tube sheet leaks Painted steel cabinets for superior strength and corrosion resistance Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Large electrical panel to facilitate ease of access Quality Sight glass is easily viewable Fixed high pressure switch eliminates capillary tubes Refrigeration duty, rifled copper condenser tubing Piping is pre-bent to eliminate braze joints, where possible, to reduce leak potential All joints are sweat type connections, no mechanical joints to leak Separate sub-cooling circuit in condenser for added capacity and vapor free liquid Pressure relief valve on receiver ServiceMate diagnostic module standard on all non-beacon II condensing unit Components Compressor Units feature Bitzer semi-hermetic compressors. Spring-mounted compressors with suction and discharge eliminators Receivers are sized for sufficient pumpdown capacity with inlet and outlet service valves Other Sealed sight glass and liquid line filter Certifications Nomenclature 162 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

168 Air-Cooled Condensing Units HP Dual Compressor Configurable s Pricing Configurable s Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Parallel-piped units include replaceable core suction filter, replaceable liquidline filter, suction accumulator, and oil management system. Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pump-down switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose ServiceMate Diagnostic Module Need to customize? Look at the factory-installed options starting on page 165. Beacon II Outdoor Prepainted galvanized cabinet with easily removable service panels Condenser built with rifled tubing and a separate subcooler coil for extra performance Flooded head pressure valves on all models Liquid line with drier, sight glass, and shut-off valve Electronic oil safety control Spring mounted compressors with suction and discharge vibration eliminators Large electrical panel, including compressor contactor and pumpdown switch Fixed high pressure control and separate adjustable low pressure control with flexible braided hose Wired for Beacon II control with fan cycling. Outdoor Beacon II Outdoor Voltage Type Notes Individually Piped s: Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD300BM6C 76,580 JDDS300BM6C 79, /3/60 Individually Piped - JLD300BM6D 77,499 JDDS300BM6D 80, /3/60 Individually Piped - JLD400BM6C 89,288 JDDS400BM6C 92, /3/60 Individually Piped - JLD400BM6D 90,360 JDDS400BM6D 93, /3/60 Individually Piped - JLD440BM6C 101,671 JDDS440BM6C 105, /3/60 Individually Piped - JLD440BM6D 102,892 JDDS440BM6D 106, /3/60 Individually Piped - JLD500BM6C 114,194 JDDS500BM6C 117, /3/60 Individually Piped - JLD500BM6D 115,564 JDDS500BM6D 119, /3/60 Individually Piped - JLD600BM6C 120,502 JDDS600BM6C 124, /3/60 Individually Piped - JLD600BM6D 121,947 JDDS600BM6D 125, /3/60 Individually Piped - JLD660BM6C 134,975 JDDS660BM6C 139, /3/60 Individually Piped - JLD660BM6D 136,594 JDDS660BM6D 141, /3/60 Individually Piped - JLD700BM6C 150,945 JDDS700BM6C 155, /3/60 Individually Piped - JLD700BM6D 152,756 JDDS700BM6D 157, /3/60 Individually Piped - JLD800BM6C 166,007 JDDS800BM6C 171, /3/60 Individually Piped - JLD800BM6D 167,998 JDDS800BM6D 173, /3/60 Individually Piped - JLD110BM6C 190,930 JDDS110BM6C 197, /3/60 Individually Piped - JLD110BM6D 193,222 JDDS110BM6D 199, /3/60 Individually Piped - Individually Piped s: Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD260BL6C 79,200 JDDS260BL6C 81, /3/60 Individually Piped - JLD260BL6D 80,309 JDDS260BL6D 83, /3/60 Individually Piped - JLD300BL6C 88,065 JDDS300BL6C 91, /3/60 Individually Piped - JLD300BL6D 89,299 JDDS300BL6D 92, /3/60 Individually Piped - JLD400BL6C 102,524 JDDS400BL6C 106, /3/60 Individually Piped - JLD400BL6D 103,958 JDDS400BL6D 107, /3/60 Individually Piped - JLD440BL6C 111,082 JDDS440BL6C 114, /3/60 Individually Piped - JLD440BL6D 112,639 JDDS440BL6D 116, /3/60 Individually Piped - JLD500BL6C 123,251 JDDS500BL6C 127, /3/60 Individually Piped - Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 163

169 Air-Cooled Condensing Units HP Dual Compressor Configurable s Pricing Section 2 Outdoor Beacon II Outdoor Voltage Type Notes JLD500BL6D 124,976 JDDS500BL6D 129, /3/60 Individually Piped - JLD600BL6C 130,093 JDDS600BL6C 134, /3/60 Individually Piped - JLD600BL6D 131,916 JDDS600BL6D 136, /3/60 Individually Piped - JLD800BL6C 150,945 JDDS800BL6C 156, /3/60 Individually Piped - JLD800BL6D 153,060 JDDS800BL6D 158, /3/60 Individually Piped - Parallel-Piped s: Medium Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD300BM6CPP 91, /3/60 Parallel Piped - JLD300BM6DPP 92, /3/60 Parallel Piped - JLD400BM6CPP 107, /3/60 Parallel Piped - JLD400BM6DPP 108, /3/60 Parallel Piped - JLD440BM6CPP 122, /3/60 Parallel Piped - JLD440BM6DPP 123, /3/60 Parallel Piped - JLD500BM6CPP 137, /3/60 Parallel Piped - JLD500BM6DPP 138, /3/60 Parallel Piped - JLD600BM6CPP 144, /3/60 Parallel Piped - JLD600BM6DPP 146, /3/60 Parallel Piped - JLD660BM6CPP 161, /3/60 Parallel Piped - JLD660BM6DPP 163, /3/60 Parallel Piped - JLD700BM6CPP 181, /3/60 Parallel Piped - JLD700BM6DPP 183, /3/60 Parallel Piped - JLD800BM6CPP 199, /3/60 Parallel Piped - JLD800BM6DPP 201, /3/60 Parallel Piped - JLD110BM6CPP 229, /3/60 Parallel Piped - JLD110BM6DPP 231, /3/60 Parallel Piped - Parallel-Piped s: Low Temperature (R-404A/507, R-407A/R-407F, R-407C, and R-448A/R-449A) JLD260BL6CPP 95, /3/60 Parallel Piped - JLD260BL6DPP 96, /3/60 Parallel Piped - JLD300BL6CPP 105, /3/60 Parallel Piped - JLD300BL6DPP 107, /3/60 Parallel Piped - JLD400BL6CPP 123, /3/60 Parallel Piped - JLD400BL6DPP 124, /3/60 Parallel Piped - JLD440BL6CPP 133, /3/60 Parallel Piped - JLD440BL6DPP 135, /3/60 Parallel Piped - JLD500BL6CPP 147, /3/60 Parallel Piped - JLD500BL6DPP 149, /3/60 Parallel Piped - JLD600BL6CPP 156, /3/60 Parallel Piped - JLD600BL6DPP 158, /3/60 Parallel Piped - JLD800BL6CPP 181, /3/60 Parallel Piped - JLD800BL6DPP 183, /3/60 Parallel Piped s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

170 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes DFT.001 Defrost Timers - Air All - Individually Piped DFT.001P Defrost Timers - Air All - Parallel Piped Medium temperature applications only. Medium temperature applications only. Adder Outdoor Beacon II Outdoor 1, FCY Fan Cycling - Temperature 260B-500B Individually Piped Fan closest to the header is not cycled. 3,569 - FCY.001-1P Fan Cycling - Temperature 260B-500B Parallel Piped Fan closest to the header is not cycled. 2,888 - FCY Fan Cycling - Temperature 600B-700B Individually Piped Fan closest to the header is not cycled. 4,250 - FCY.001-2P Fan Cycling - Temperature 600B-700B Parallel Piped Fan closest to the header is not cycled. 3,569 - FCY Fan Cycling - Temperature 800B & 110B Individually Piped Fan closest to the header is not cycled. 4,848 - FCY.001-3P Fan Cycling - Temperature 800B & 110B Parallel Piped Fan closest to the header is not cycled. 4,167 - FCY Fan Cycling - Pressure 260B-500B Individually Piped Fan closest to the header is not cycled. 3,569 Standard FCY.002-1P Fan Cycling - Pressure 260B-500B Parallel Piped Fan closest to the header is not cycled. 2,888 - FCY Fan Cycling - Pressure 600B-700B Individually Piped Fan closest to the header is not cycled. 4,250 Standard FCY.002-2P Fan Cycling - Pressure 600B-700B Parallel Piped Fan closest to the header is not cycled. 3,569 - FCY Fan Cycling - Pressure 800B & 110B Individually Piped Fan closest to the header is not cycled. 4,848 Standard FCY.002-3P Fan Cycling - Pressure 800B & 110B Parallel Piped Fan closest to the header is not cycled. 4,167 - CBK Compressor Circuit Breakers 230V - Individually Piped - 5,273 5,273 CBK.002-2P Compressor Circuit Breakers 230V - Parallel Piped - 5,273 - CBK Compressor Circuit Breakers 460V - Individually Piped - 2,451 2,451 CBK.002-1P Compressor Circuit Breakers 460V - Parallel Piped - 2,451 - PLM.00X Phase Loss Monitors All - Individually Piped - 1,153 1,153 PLM.00XP Phase Loss Monitors All - Parallel Piped - 1,153 - TDR.002 Anti-short Cycling Timers All - Individually Piped - 1,329 1,329 TDR.002P Anti-short Cycling Timers All - Parallel Piped HPS.001 HPS.001P Manual Reset High Pressure Switches Manual Reset High Pressure Switches All - Individually Piped All - Parallel Piped Section 2 Rev. 01/18 Regulation Requires Variable Speed Fan Motors! California Energy Commission Title 24, Section 126 Effective 01/01/2010, refrigerated warehouses with a total cold storage and frozen storage area exceeding 3,000 square feet require: 1. All condenser fans for air-cooled condensers/condensing units shall be continuously variable speed and the condensing temperature or pressure control system shall control the speed of all condenser fans serving a common condenser loop in unison. The minimum condensing temperature set point shall be less than or equal to 70 degrees Fahrenheit or reset in response to ambient dry bulb temperature or refrigeration system load. 2. All single phase condenser/condensing unit fan motors less than 1 horsepower and less than 460 volts shall be either permanent split capacitor or electronically commutated. s Effective January 1 st s and specifications subject to change without notice. 165

171 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code MS.0014S-1 MS.0014S-2 MS.0014L-1 MS.0014L-2 MS.0016L-1 MS.0016L-2 MS.0018L-1 MS.0018L-2 Mechanical Options LIQ LIQ.003-1P LIQ LIQ.003-2P LIQ LIQ.003-3P Description s Used On Notes Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Variable Speed EC Motor with proportional pressure controller Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses Replaceable core liquid-line filter driers & sight glasses 300BM6 Parallel Piped (230V & 460V) 260B-400BL6 Parallel Piped (230V & 460V) 300BM6 Individually Piped (230V & 460V) 260B-400BL6 Individually Piped (230V & 460V) 400B-500BM6 Parallel Piped (230V & 460V) 440B-600BL6 Parallel Piped (230V & 460V) 400B-500BM6 Individually Piped (230V & 460V) 440B-600BL6 Individually Piped (230V & 460V) 600B-700BM6 Parallel Piped (230V & 460V) 800BL6 Parallel Piped (230V & 460V) 600B-700BM6 Individually Piped (230V & 460V) 800BL6 Individually Piped (230V & 460V) 800B - 110BM6 Parallel Piped (230V & 460V) 800B - 110BM6 Individually Piped (230V & 460V) Adder Outdoor Beacon II Outdoor - 24, ,849 26,849-36, ,211 38,211-52, ,142 55,142-69, ,073 72, B-440B Individually Piped B-440B Parallel Piped - Standard - 500B-800B Individually Piped - 1,394 1, B-800B Parallel Piped - Standard - 110B Individually Piped - 1,675 1, B Parallel Piped - Standard - SUC Suction-line filters 260B-440B Individually Piped - 2,578 2,578 SUC.003-1P Suction-line filters 260B-440B Parallel Piped - N/A - SUC Suction-line filters 500B-800B Individually Piped - 3,302 3,302 SUC.003-2P Suction-line filters 500B-800B Parallel Piped - N/A - SUC Suction-line filters 110B Individually Piped - 4,132 4,132 SUC.003-3P Suction-line filters 110B Parallel Piped - N/A - SUC SUC.005-1P Replaceable core suction-line filters Replaceable core suction-line filters 260B-440B Individually Piped - 3,376 3, B-440B Parallel Piped - Standard s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

172 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code SUC SUC.005-2P SUC Description s Used On Notes Replaceable core suction-line filters Replaceable core suction-line filters Replaceable core suction-line filters LIQ Liquid-line solenoid valves 260B-440B Individually Piped LIQ.002-1P Liquid-line solenoid valves 260B-440B Parallel Piped LIQ Liquid-line solenoid valves 500B-800B Individually Piped LIQ.002-2P Liquid-line solenoid valves 500B-800B Parallel Piped LIQ Liquid-line solenoid valves 110B Individually Piped LIQ.002-3P Liquid-line solenoid valves 110B Parallel Piped Adder Outdoor Beacon II Outdoor 500B-800B Individually Piped - 3,526 3, B-800B Parallel Piped - Standard - 110B Individually Piped - 4,406 4,406 Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. 1,913-1,026-2,052-1,383-2,464 - Call Factory - SUC Suction accumulators 260B-440B Individually Piped - 5,511 5,511 SUC.007-1P Suction accumulators 260B-440B Parallel Piped - Standard - SUC Suction accumulators 500B-800B Individually Piped - 6,320 6,320 SUC.007-2P Suction accumulators 500B-800B Parallel Piped - Standard - SUC Suction accumulators 110B Individually Piped - 8,215 8,215 SUC.007-3P Suction accumulators 110B Parallel Piped - Standard - DIS DIS.001-1P DIS DIS.001-2P DIS DIS.001-3P Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves Oil separators with discharge line check valves 260B-600B Individually Piped - 3,302 3, B-600B Parallel Piped - Standard - 660B-800B Individually Piped - 5,585 5, B-800B Parallel Piped - Standard - 110B Individually Piped - 6,705 6, B Parallel Piped - Standard - MUF.001 Discharge mufflers All - Individually Piped MUF.001P Discharge mufflers All - Parallel Piped - N/A - DIS DIS.002-1P DIS Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed 260B-400B Individually Piped - 3, B-400B Parallel Piped - Call Factory - 440B-800B Individually Piped - 4,997 - Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 167

173 Air-Cooled Condensing Units HP Dual Compressor Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code DIS.002-2P DIS DIS.002-3P UNL.001 UNL.001P REC REC.001-1P REC REC.001-2P Coil Options CSG.PRO-1 CSG.PRO-2 CSG.PRO-3 CSG.PRO-4 Description s Used On Notes Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Three way heat reclam valves with check valves installed Compressor Unloading - with pressure control for (1) cyl. Bank Compressor Unloading - with pressure control for (1) cyl. Bank Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Low Ambient kits with heated and insulated receivers and time delay relays Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection Guard condenser fin protection Adder Outdoor Beacon II Outdoor 440B-800B Parallel Piped - Call Factory - 110B Individually Piped - 5, B Parallel Piped - Call Factory - All - Individually Piped - 3,392 - All - Parallel Piped - 3, B-500B Individually Piped - 5,218 5, B-500B Parallel Piped - 5, B-110B Individually Piped - 6,855 6, B-110B Parallel Piped - 6, BM6, 260B-400BL6-3,354 3, B-500BM6, 440B-600BL6-5,585 5, B-700BM6, 800BL6-6,259 6, B-110BM6-8,346 8,346 CS.ELEC-1 ElectroFin coil coating 300BM6, 260B-400BL6 - Call Factory Call Factory CS.ELEC-2 ElectroFin coil coating 400B-500BM6, 440B-600BL6 - Call Factory Call Factory CS.ELEC-3 ElectroFin coil coating 600B-700BM6, 800BL6 - Call Factory Call Factory CS.ELEC-4 ElectroFin coil coating 800B-110BM6 - Call Factory Call Factory CSB.CPR-1 Copper condenser fins 300BM6, 260B-400BL6 - Call Factory Call Factory CSB.CPR-2 Copper condenser fins 400B-500BM6, 440B-600BL6 - Call Factory Call Factory CSB.CPR-3 Copper condenser fins 600B-700BM6, 800BL6 - Call Factory Call Factory CSB.CPR-4 Copper condenser fins 800B-110BM6 - Call Factory Call Factory CS.BRZ-1 Bronz-Glow coil coating 300BM6, 260B-400BL6 - Call Factory Call Factory CS.BRZ-2 Bronz-Glow coil coating 400B-500BM6, 440B-600BL6 - Call Factory Call Factory CS.BRZ-3 Bronz-Glow coil coating 600B-700BM6, 800BL6 - Call Factory Call Factory CS.BRZ-4 Bronz-Glow coil coating 800B-110BM6 - Call Factory Call Factory 168 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

174 Air-Cooled Condensing Units HP Dual Compressor Factory-Installed Electric Defrost Options Need an electric defrost kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, contact your local Sales Representative or Account Engineer to find out the rated defrost power amps for both the fan motor amps and electric heater amps. The condensing unit data plate ratings are based on the actual system match. Your local Sales Representative or Account Engineer will help you select the proper electric defrost kit and components. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Evaporator Hold Out Relay Allows each evaporator to individually terminate defrost on temperature when multiple evaporators are used in a single system. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Section 2 Rev. 01/18 Option Code DFT DFT.016P DFT DFT DFT.013P DFT Description s Used On Notes Electric Defrost Kit for system with one evaporator per compressor circuit Electric Defrost Kit for system with one evaporator per compressor circuit Electric Defrost Kit for system with one evaporator per compressor circuit Electric Defrost Kit for system with two evaporators per compressor circuit Electric Defrost Kit for system with two evaporators per compressor circuit Electric Defrost Kit for system with two evaporators per compressor circuit 300B-400BM6 (230V) Individually Piped 260B-440BL6 (230V) Individually Piped All s (460V) Individually Piped 300B-400BM6 (230V) Parallel Piped 260B-440BL6 (230V) Parallel Piped All s (460V) Parallel Piped 440B-110BM6 (230V) 500B-800BL6 (230V) 300B-600BM6 (230V) Individually Piped All L6 s (230V) Individually Piped All s (460V) Individually Piped 300B-400BM6 (230V) Parallel Piped 260B-440BL6 (230V) Parallel Piped All s (460V) Parallel Piped 660B-110BM6 (230V) SDK.001 InterLink Smart Defrost Kit All - Individually Piped SDK.001P InterLink Smart Defrost Kit All - Parallel Piped Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (1) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Includes (1) electric defrost timer, (2) heater & (1) fan contactors, terminal strip, and fusing. 48 amp maximum heater load per heater contactor. Can not be used alone. Must also select a electric defrost timer or electric defrost kit. Can not be used alone. Must also select a electric defrost timer or electric defrost kit. s Effective January 1 st s and specifications subject to change without notice. Adder Outdoor 4,579 4,019 Call Factory 7,811 7,282 Call Factory 1,739 N/A 169

175 Air-Cooled Condensing Units HP Dual Compressor Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Must have one valve per compressor. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 7/8" /8" /8" 4227W 1, /8" 4262Q 2, /8" , /8" ,926 Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

176 Water-Cooled Condensing Units ½ - 6 HP Overview Product Description: The 1/2 through 6 HP water cooled condensing unit product line features hermetic and scroll compressors. These condensing units component selection, location, base and unit dimensions are all optimized for easy field replacement or installation in new applications where space is limited. The electrical box is designed with extra space for easier servicing. The area is large enough to accommodate circuit breakers, compressor contactors, time clocks and all start components in one enclosure. Standard features include: compressor isolation valves that enable service technicicans to isolate the compressor for service and an oversized receiver which provides total refrigerant pump down. These products are ideal for units requiring long runs. Cabinet & Construction Component location and unit size are optimized for easy field replacement and space limited applications Serviceability Large electrical box allows easy service and installation of additional components A pump-down switch is provided on all models for easy field servicing Color-coded wire harnesses are labeled and coded for easy identification Suction line rotolock service valve is provided on the compressor for service An additional shut-off valve is mounted in the discharge line of the compressor for quick and easy compressor isolation Quality Sight glass (optional) is easily viewable Every unit is subjected to a helium leak test to ensure the unit is leak free Shipped with nitrogen holding charge to enable installer to verify unit is leakfree upon arrival Every unit is run-tested and cycled on both the high and low pressure controls All electrical circuits are also tested for functional integrity Components Features Copeland hermetic and Scroll compressors Compressors are mounted with vibration eliminating rubber grommets All units come standard with a water regulating valve for superior head pressure control Oversized receiver with liquid shut-off valve is provided for installations with long refrigerant lines Section 2 Certifications Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 171

177 Water-Cooled Condensing Units ½ - 6 HP Configurable s Pricing Compressor mounting (rubber grommets) Compressor discharge service valve (in line brass base valve) Compressor suction service valve rotolock Large capacity refrigerant receiver (up to 100 ft. runs) Receiver service valve (located on outlet) Coaxial condenser (counterflow tube in tube) Extra large electric box (encloses all options and start components) Electric conduit (UL recognized, high impact, flame retardant copolymer) Standard Features Low pressure control switch (adjustable) High pressure encapsulated safety switch (fixed) Superhose on low pressure control (higher leak resistance) Liquid injection (Scroll low temperature models only) Pump-down control switch (pre-wired) Water valve (mounted on condenser inlet) Agency approvals UL, ULC Need to customize? Look at the factory-installed options starting on page 174. Section 2 Voltage Notes Hermetic High Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) HWN005H6B 3, /1/60 See footnote 1,2 HWN009H6B 4, /1/60 See footnote 1,2 HWN010H6B 4, /1/60 See footnote 1,2 HWN010H6C 4, /3/60 See footnote 1,2 HWN015H6B 4, /1/60 - HWN015H6C 4, /3/60 - HWN025H6B 5, /1/60 - HWN025H6C 5, /3/60 - HWN032H6B 6, /1/60 - HWN032H6C 7, /3/60 - Hermetic Extended Temperature (R-404A/R-507A, R-407A/R- 407C, R-448A/R-449A) HWN005X6B 3, /1/60 See footnote 1 HWN008X6B 3, /1/60 See footnote 1 HWN009X6B 4, /1/60 See footnote 1 HWN010X6B 4, /1/60 See footnote 1 HWN010X6C 4, /3/60 See footnote 1 Hermetic Extended/Medium Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) HWN015X6B 4, /1/60 - HWN015X6C 4, /3/60 - HWN020X6B 5, /1/60 - HWN020X6C 5, /3/60 - HWN025X6B 5, /1/60 - HWN025X6C 5, /3/60 - HWN025X6D 6, /3/60 - HWN030X6B 6, /1/60 - HWN030X6C 6, /3/60 - HWN030X6D 7, /3/60 - HWN032X6B 6, /1/60 - HWN032X6C 7, /3/60 - HWN032X6D 7, /3/60 - Voltage Notes Hermetic Low Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) HWN011L6B 4, /1/60 - HWN011L6C 4, /3/60 - HWN014L6B 4, /1/60 - HWN014L6C 4, /3/60 - HWN025L6B 4, /1/60 - HWN025L6C 4, /3/60 - HWN031L6B 6, /1/60 - HWN031L6C 7, /3/60 - HWN031L6D 7, /3/60 - Scroll Extended Temperature (R-404A/R-507A, R-407A/R- 407C, R-448A/R-449A) ZWN010X6B 7, /1/60 - ZWN010X6C 7, /3/60 - ZWN010X6D 8, /3/60 - ZWN015X6B 8, /1/60 - ZWN015X6C 8, /3/60 - ZWN015X6D 8, /3/60 - ZWN020X6B 8, /1/60 - ZWN020X6C 8, /3/60 - ZWN020X6D 8, /3/60 - ZWN025X6B 8, /1/60 - ZWN025X6C 8, /3/60 - ZWN025X6D 9, /3/60 - ZWN030X6B 8, /1/60 - ZWN030X6C 9, /3/60 - ZWN030X6D 9, /3/60 - ZWN035X6B 9, /1/60 - ZWN035X6C 9, /3/60 - ZWN035X6D 9, /3/60 - ZWN045X6B 9, /1/60 - ZWN045X6C 10, /3/60 - ZWN045X6D 10, /3/60 - Notes: 1. Suitable for R-407C 2. Scroll L6 models must have a liquid line option specified. 172 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

178 Water-Cooled Condensing Units ½ - 6 HP Configurable s Pricing Voltage Notes ZWN055X6B 10, /1/60 - ZWN055X6C 10, /3/60 - ZWN055X6D 10, /3/60 - ZWN060X6C 12, /3/60 - ZWN060X6D 12, /3/60 - Scroll Low Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) ZWN020L6B 8, /1/60 - ZWN020L6C 8, /3/60 - ZWN020L6D 8, /3/60 - ZWN025L6B 9, /1/60 - ZWN025L6C 9, /3/60 - ZWN025L6D 9, /3/60 - ZWN030L6B 9, /1/60 See footnote 2 ZWN030L6C 9, /3/60 See footnote 2 ZWN030L6D 10, /3/60 See footnote 2 ZWN035L6B 9, /1/60 See footnote 2 ZWN035L6C 10, /3/60 See footnote 2 ZWN035L6D 10, /3/60 See footnote 2 ZWN045L6B 10, /1/60 See footnote 2 ZWN045L6C 10, /3/60 See footnote 2 ZWN045L6D 10, /3/60 See footnote 2 ZWN055L6B 10, /1/60 See footnote 2 ZWN055L6C 10, /3/60 See footnote 2 ZWN055L6D 11, /3/60 See footnote 2 ZWN060L6C 12, /3/60 See footnote 2 ZWN060L6D 12, /3/60 See footnote 2 Section 2 Notes: 1. Not Suitable for R Scroll L6 models must have a liquid line option specified. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 173

179 Water-Cooled Condensing Units ½ - 6 HP Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 2 Option Code Electrical Options Description s Used On Notes Adder DFT.001 Defrost Timer - Air All H2, X6 Medium temperature applications only. 562 Mechanical Options LIQ Liquid-line Drier & Sight Glass LIQ Liquid-line Drier & Sight Glass LIQ Liquid-line Drier, Sight Glass & Solenoid Valve ,125 LIQ Liquid-line Drier, Sight Glass & Solenoid Valve ,210 SUC Suction-line filter SUC Suction-line filter SUC Suction accumulator SUC Suction accumulator SUC Suction-line filter & accumulator SUC Suction-line filter & accumulator , s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

180 Water-Cooled Condensing Units ½ - 6 HP Factory-Installed Electric Defrost Options Need an electric defrost timer or kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, find the rated defrost power amps for both the fan motor amps and electric heater amps. If the evaporator total fan motor amps and electric defrost heater amps calculated in Step 1 are less than the condensing unit s rated defrost power amps found in Step 2 then proceed below to select the appropriate kit/ components and list price adders. If not then contact your local Sales Representative or Account Engineer for assistance. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Not available on electric defrost timer only options. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Section 2 Option Code Description s Used On Notes Adder DFT.002 Defrost Timer - Electric L6, H2, X6 ( V) DFT.007 Electric Defrost Kit HWN: H2, X6 ( V) ZWN: X6, L6 ( V) All: H2, X6, L6 (460V) SDK.001 InterLink Smart Defrost Kit and L6, H2, X6 Includes (1) electric defrost timer, (1) heater & (1) fan contactors, and (1) lockout relay. Can not be used alone. Must also select a electric defrost timer or electric defrost kit Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 175

181 Water-Cooled Condensing Units ½ - 6 HP Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1,705 Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

182 Water-Cooled Condensing Units ¾ - 22 HP Overview Product Description: The 3/4 through 22 HP water-cooled condensing unit product line features semi-hermetic compressors. These condensing units are vessel-mounted indoor watercooled condensing units complete with a shell and tube condenser. The cleanable condenser is perfect for applications where air-cooled condensers would not be practical and/or areas where water is readily available. These units provide an economical, compact alternative to traditional air-cooled condensing units. Cabinet & Construction Component location and unit size are optimized for easy field replacement and space limited applications Serviceability Spacious, pre-painted electrical box Pump-down switch Easy access refrigerant piping Captive door fasteners Single electrical connection location Removable electrical box provides convenient front access to the oil pump and compressor Quality Pre-bent tubing reduces the possibility of leaks Shipped with a dry nitrogen holding charge Heavy duty metal base plate Non-metallic conduit on all wiring runs Components Semi-hermetic reciprocating compressors Rigid mounted compressors on models and spring mounted compressors with suction and discharge vibration eliminators on models 0499 and above Fixed low pressure switch (adjustable on low temperature models) Fixed high pressure switch Sealed liquid line filter drier and sight glass Section 2 Certifications: Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 177

183 Water-Cooled Condensing Units ¾ - 22 HP Configurable s Pricing Solid mounted semi-hermetic Reed and Discus compressors up to and including 0400 Spring mounted compressor 0499 and above Oil pressure switch (where required) High-low pressure controls Standard Features Compressor contactor Shell and tube water-cooled condenser with pressure relief Liquid-line filter drier and sight glass Pump-down switch Need to customize? Look at the factory-installed options starting on page 179. Section 2 Voltage Notes Semi-Hermetic Medium Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) SWN0090M6B 9, /1/60 - SWN0090M6C 9, /3/60 - SWN0199M6B 11, /1/60 - SWN0199M6C 11, /3/60 - SWN0200M6C 12, /3/60 - SWN0310M6C 14, /3/60 - SWN0310M6D 15, /3/60 - SWN0310M6E 16, /3/60 - SWN0500M6C 17, /3/60 See footnote 1 SWN0500M6D 18, /3/60 See footnote 1 Semi-Hermetic Low Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) SWN0150L6B 10, /1/60 - SWN0150L6C 10, /3/60 - SWN0150L6D 11, /3/60 - SWN0200L6C 12, /3/60 - SWN0210L6B 12, /1/60 - SWN0210L6C 12, /3/60 - SWN0210L6D 14, /3/60 - SWN0210L6E 14, /3/60 - SWN0310E6C 14, /3/60 - SWN0310E6D 15, /3/60 - SWN0310L6C 14, /3/60 - SWN0310L6D 15, /3/60 - SWN0310L6E 16, /3/60 - SWN0311L6C 16, /3/60 See footnote 2 SWN0311L6D 18, /3/60 See footnote 2 SWN0311L6E 18, /3/60 See footnote 2 SWN0400L6C 18, /3/60 See footnote 2 SWN0400L6D 19, /3/60 See footnote 2 SWN0400L6E 20, /3/60 See footnote 2 SWN0599L6C 18, /3/60 See footnote 2 SWN0599L6D 20, /3/60 See footnote 2 SWN0599L6E 20, /3/60 See footnote 2 Voltage Notes SWN0600L6C 19, /3/60 See footnote 2 SWN0600L6D 21, /3/60 See footnote 2 SWN0600L6E 21, /3/60 See footnote 2 SWN0601L6C 21, /3/60 See footnote 2 SWN0601L6D 22, /3/60 See footnote 2 SWN0601L6E 23, /3/60 See footnote 2 SWN0750L6C 22, /3/60 See footnote 2 SWN0750L6D 24, /3/60 See footnote 2 SWN0750L6E 25, /3/60 See footnote 2 SWN0900L6C 25, /3/60 See footnote 2 SWN0900L6D 27, /3/60 See footnote 2 SWN0900L6E 27, /3/60 See footnote 2 SWN1000L6C 27, /3/60 See footnote 2 SWN1000L6D 28, /3/60 See footnote 2 SWN1000L6E 29, /3/60 See footnote 2 SWN1500L6C 33, /3/60 See footnote 2 SWN1500L6D 34, /3/60 See footnote 2 SWN1500L6E 35, /3/60 See footnote 2 SWN2200L6C 39, /3/60 See footnote 2 SWN2200L6D 40, /3/60 See footnote 2 SWN2200L6E 41, /3/60 See footnote 2 Notes: 1. Suitable for R-407A, R-407C, R-448A/R-449A) 2. Suitable for R-407A, R-407C, R407F 178 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

184 Water-Cooled Condensing Units ¾ - 22 HP Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes Adder DFT.001 Defrost Timer - Air All H2, M2, M6 Medium temperature applications only. 562 CBK Circuit Breakers (Compressor & Control Circuit) ( /1/60 or 230V/1/60) CBK Circuit Breakers (Compressor & Control Circuit) (230V/3/60) CBK Circuit Breakers (Compressor & Control Circuit) (460V/3/60) - 1,385 CBK Circuit Breakers (Compressor & Control Circuit) 2200L6C - 2,186 CCH.001 Crankcase Heater All SW.002 Mechanical Options Dual pressure control with adjustable high & low pressure settings All LIQ.003 Replaceable core liquid-line filter drier & sight glass LIQ Liquid-line solenoid valve LIQ Liquid-line solenoid valve LIQ Liquid-line solenoid valve CMT.002 Spring Mounted Compressor Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Includes discharge and suction vibration eliminators. Standard on 0499 and above SUC Suction-line filter SUC Suction-line filter SUC.005 Replaceable core suction-line filter ,270 SUC Suction accumulator SUC Suction accumulator SUC.010 Suction-line filter ,247 SUC.012 Replaceable core suction-line filter ,270 SUC Suction accumulator ,307 SUC Suction accumulator 1500H2-2000H2 & 1500L6-2200L ,388 DIS.001 Oil separator with discharge line check valve ,323 DIS Oil separator with discharge line check valve ,323 DIS Oil separator with discharge line check valve ,397 DIS Oil separator with discharge line check valve ,653 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 179

185 Water-Cooled Condensing Units ¾ - 22 HP Factory-Installed Electric Defrost Options Section 2 Need an electric defrost timer or kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, find the rated defrost power amps for both the fan motor amps and electric heater amps. If the evaporator total fan motor amps and electric defrost heater amps calculated in Step 1 are less than the condensing unit s rated defrost power amps found in Step 2 then proceed below to select the appropriate kit/ components and list price adders. If not then contact your local Sales Representative or Account Engineer for assistance. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Not available on electric defrost timer only options. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Option Code Description s Used On Notes DFT Electric Defrost Kit (Low Amps) , (460V) DFT Electric Defrost Kit (Low Amps) (230V) DFT Electric Defrost Kit (High Amps) 0150H2B, 0199M6B, , (460V) DFT Electric Defrost Kit (High Amps) (230V), DEF DEF DEF DEF Fuses for electric defrost kits (Low Amps) Fuses for electric defrost kits (Low Amps) Fuses for electric defrost kits (High Amps) Fuses for electric defrost kits (High Amps) SDK.001 InterLink Smart Defrost Kit All Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Adder 987 1, , H2B, 0199M6B, Can not be used alone. Must also select a electric defrost timer or electric defrost kit s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

186 Water-Cooled Condensing Units ¾ - 22 HP Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Mechancial Options Description s Used On Notes Water Regulating Valve Water Regulating Valve Water Regulating Valve , Water Regulating Valve 1000, 1500L6, 2200L6-1, Water Regulating Valve 1500H2, 2000H2-3, Two Tier Rack (Small) , Two Tier Rack (Large) ,453 Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1, /8" 4262Q 2,669 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 181

187 Remote Compressor Units ¾ - 22 HP Overview Section 2 Product Description The indoor SRN and ZRN remote compressor units feature semi-hermetic or Scroll compressors. These units are specicially designed for use in supermarket restaurant, warehouse and other commercial and industrial applications. The design focuses on easy of installation and maintenance along with the flexibility to fit most application requirements. Cabinet & Construction Spacious, pre-painted electrical box Fixed low pressure switch (adjustable on low temp models) Fixed high pressure switch Pump down switch 230V control circuit transformer on 460V units Standard 16-3/4 tall box - (large 29-1/4 tall box is standard when defrost components are selected) Sealed liquid line filter drier and sight glass Serviceability Easy access refrigerant piping Captive door fasteners Single electrical connection location Removable electrical box provides convenient front access to the oil pump and compressor Quality Every unit is subjected to a helium leak test to ensure the unit is leak free Shipped with nitrogen holding charge to enable installer to verify unit is leakfree upon arrival All the units are completely leak tested in a helium environment, compressor is bump tested and high and low pressure controls are cycled. Each unit has a copy of the run data shipped inside the electrical panel. Components Pre-bent tubing reduces the possibility of leaks Shipped with dry nitrogen charge Heavy duty base plate Non-metallic conduit on all wiring runs Certifications Nomenclature 182 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

188 Remote Compressor Units ¾ - 22 HP Configurable s Pricing Standard Features Solid mounted semi-hermetic Reed and Discus compressors up to and including 0400 Spring mounted compressor 0499 and above Oil pressure switch (where required) High-low pressure controls Compressor contactor Liquid receiver with pressure relief Liquid-line filter drier and sight glass Pump-down switch Need to customize? Look at the factory-installed options starting on page 185. Voltage Notes Semi-Hermetic Medium Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) SRN0090M6B 8, /1/60 - SRN0090M6C 8, /3/60 - SRN0199M6B 9, /1/60 - SRN0199M6C 9, /3/60 - SRN0200M6C 10, /3/60 - SRN0310M6C 11, /3/60 - SRN0310M6D 12, /3/60 - SRN0310M6E 13, /3/60 - SRN0500M6C 13, /3/60 See footnote 1 SRN0500M6D 15, /3/60 See footnote 1 SRN0500M6E 15, /3/60 See footnote 1 Semi-Hermetic Low Temperature (R-404A/R-507A, R-407A/ R-407C, R-448A/R-449A) SRN0150L6B 8, /1/60 - SRN0150L6C 8, /3/60 - SRN0150L6D 10, /3/60 - SRN0200L6C 10, /3/60 - SRN0210L6B 10, /1/60 - SRN0210L6C 10, /3/60 - SRN0210L6D 12, /3/60 - SRN0210L6E 12, /3/60 - SRN0310E6C 11, /3/60 - SRN0310E6D 13, /3/60 - SRN0310L6C 11, /3/60 - SRN0310L6D 13, /3/60 - SRN0310L6E 13, /3/60 - SRN0311L6C 13, /3/60 See footnote 2 SRN0311L6D 15, /3/60 See footnote 2 SRN0311L6E 15, /3/60 See footnote 2 SRN0400L6C 15, /3/60 See footnote 2 SRN0400L6D 16, /3/60 See footnote 2 SRN0400L6E 17, /3/60 See footnote 2 SRN0599L6C 15, /3/60 See footnote 2 SRN0599L6D 17, /3/60 See footnote 2 SRN0599L6E 17, /3/60 See footnote 2 SRN0600L6C 15, /3/60 See footnote 2 SRN0600L6D 17, /3/60 See footnote 2 SRN0600L6E 17, /3/60 See footnote 2 Voltage Notes SRN0601L6C 16, /3/60 See footnote 2 SRN0601L6D 18, /3/60 See footnote 2 SRN0601L6E 18, /3/60 See footnote 2 SRN0750L6C 19, /3/60 See footnote 2 SRN0750L6D 21, /3/60 See footnote 2 SRN0750L6E 21, /3/60 See footnote 2 SRN0900L6C 20, /3/60 See footnote 2 SRN0900L6D 22, /3/60 See footnote 2 SRN0900L6E 23, /3/60 See footnote 2 SRN1000L6C 22, /3/60 See footnote 2 SRN1000L6D 23, /3/60 See footnote 2 SRN1000L6E 23, /3/60 See footnote 2 SRN1500L6C 27, /3/60 See footnote 2 SRN1500L6D 28, /3/60 See footnote 2 SRN1500L6E 28, /3/60 See footnote 2 SRN2200L6C 31, /3/60 See footnote 2 SRN2200L6D 32, /3/60 See footnote 2 SRN2200L6E 32, /3/60 See footnote 2 Scroll Extended Temperature (R-404A/R-507A, R-407A/R- 407C, R-448A/R-449A) ZRN020X6B 7, /1/60 - ZRN020X6C 7, /3/60 - ZRN020X6D 7, /3/60 - ZRN025X6B 7, /1/60 - ZRN025X6C 7, /3/60 - ZRN025X6D 7, /3/60 - ZRN030X6B 7, /1/60 - ZRN030X6C 7, /3/60 - ZRN030X6D 8, /3/60 - ZRN035X6B 7, /1/60 - ZRN035X6C 7, /3/60 - ZRN035X6D 8, /3/60 - ZRN045X6B 8, /1/60 - ZRN045X6C 8, /3/60 - ZRN045X6D 8, /3/60 - ZRN055X6B 7, /1/60 - ZRN055X6C 8, /3/60 - ZRN055X6D 8, /3/60 - ZRN060X6C 8, /3/60 - ZRN060X6D 9, /3/60 - Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 183

189 Remote Compressor Units ¾ - 22 HP Configurable s Pricing Section 2 Voltage Notes Scroll Medium Temperature (R-404A/R-507A, R-407A/R- 407C, R-448A/R-449A) ZRN0650M6C 12, /3/60 - ZRN0650M6D 14, /3/60 - ZRN0650M6E 14, /3/60 - ZRN0700M6C 13, /3/60 - ZRN0700M6D 15, /3/60 - ZRN0700M6E 15, /3/60 - ZRN0750M6C 13, /3/60 - ZRN0750M6D 15, /3/60 - ZRN0750M6E 16, /3/60 - ZRN0860M6C 15, /3/60 - ZRN0860M6D 15, /3/60 - ZRN0860M6E 16, /3/60 - ZRN1000M6C 18, /3/60 - ZRN1000M6D 19, /3/60 - ZRN1000M6E 19, /3/60 - ZRN1400M6C 20, /3/60 - ZRN1400M6D 21, /3/60 - ZRN1400M6E 21, /3/60 - Scroll Low Temperature (R-404A/R-507A, R-407A/R-407C, R-448A/R-449A) ZRN020L6B 8, /1/60 - ZRN020L6C 8, /3/60 - ZRN020L6D 9, /3/60 - ZRN025L6B 8, /1/60 - ZRN025L6C 8, /3/60 - ZRN025L6D 9, /3/60 - ZRN030L6B 8, /1/60 - ZRN030L6C 8, /3/60 - ZRN030L6D 10, /3/60 - ZRN035L6B 9, /1/60 - ZRN035L6C 9, /3/60 - ZRN035L6D 9, /3/60 - ZRN045L6B 9, /1/60 - ZRN045L6C 9, /3/60 - ZRN045L6D 9, /3/60 - ZRN055L6B 9, /1/60 - ZRN055L6C 9, /3/60 - ZRN055L6D 10, /3/60 - ZRN060L6C 11, /3/60 - ZRN060L6D 11, /3/60 - ZRN0750L6C 15, /3/60 - ZRN0750L6D 16, /3/60 - ZRN0750L6E 17, /3/60 - Voltage Notes ZRN1000L6C 18, /3/60 - ZRN1000L6D 20, /3/60 - ZRN1000L6E 21, /3/60 - ZRN1300L6C 20, /3/60 - ZRN1300L6D 22, /3/60 - ZRN1300L6E 22, /3/60 - ZRN1500L6C 22, /3/60 - ZRN1500L6D 22, /3/60 - ZRN1500L6E 22, /3/ s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

190 Remote Compressor Units ¾ - 22 HP Need Factory-Installed Options? Factory-Installed Options Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Electrical Options Description s Used On Notes DFT.001 Defrost Timer - Air All H2, M2, M6, X6 Medium temperature applications only. CBK Circuit Breakers (Compressor & Control Circuit) ( /1/60 or 230V/1/60) CBK Circuit Breakers (Compressor & Control Circuit) (230V/3/60) Adder CBK Circuit Breakers (Compressor & Control Circuit) (460V/3/60) - 1,385 CBK Circuit Breakers (Compressor & Control Circuit) 2200L6C - 2,186 CCH.001 Crankcase Heater All SRN SW.002 Mechanical Options Dual pressure control with adjustable high & low pressure settings LIQ.001 Liquid-line filter drier & sight glass ZRN LIQ Liquid-line solenoid valve LIQ LIQ Liquid-line solenoid valve Liquid-line solenoid valve SRN, M6 ZRN, L6 ZRN SRN, M6 ZRN, 1500L6 ZRN LIQ Liquid-line solenoid valve ZRN LIQ.003 Replaceable core liquid-line filter drier & sight glass Required on all L6 models with scroll compressors. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet. Not recommended on applications with line runs more than 25 feet , SRN, ZRN SUC Suction-line filter SRN SUC Suction-line filter ZRN SUC Suction-line filter L6 ZRN SUC Suction-line filter M6 ZRN - 1,247 SUC.005 Replaceable core suction-line filter SRN, ZRN - 1,270 SUC.010 Suction-line filter SRN - 1,247 SUC.012 Replaceable core suction-line filter 0300 & SRN - 1,270 SUC Suction accumulator SRN SUC Suction accumulator ZRN SUC Suction accumulator SRN, 0750L6-1500L6 ZRN SUC Suction accumulator 0650M6-1400M6 ZRN - 1,307 SUC Suction accumulator SRN - 1,307 SUC Suction accumulator SRN - 2,388 DIS Oil separator with discharge line check valve SRN, 0750L6-1500L6 ZRN - 1,323 DIS Oil separator with discharge line check valve 0650M6-1400M6 ZRN - 1,397 DIS Head pressure control flooding valve, fixed ZRN DIS Head pressure control flooding valve, fixed SRN, ZRN DIS Oil separator with discharge line check valve SRN - 1,323 DIS Oil separator with discharge line check valve SRN - 1,397 DIS Oil separator with discharge line check valve SRN - 1,653 DIS Head pressure control flooding valve, fixed SRN DIS Head pressure control flooding valve, fixed SRN Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 185

191 Remote Compressor Units ¾ - 22 HP Factory-Installed Electric Defrost Options Section 2 Need an electric defrost timer or kit? Selecting the proper kit is as easy as 12 3 Add up the total fan motor amps and electric heater amps for all evaporators in the refrigeration system. For the selected condensing unit, find the rated defrost power amps for both the fan motor amps and electric heater amps. If the evaporator total fan motor amps and electric defrost heater amps calculated in Step 1 are less than the condensing unit s rated defrost power amps found in Step 2 then proceed below to select the appropriate kit/ components and list price adders. If not then contact your local Sales Representative or Account Engineer for assistance. Make sure you have selected a configurable model. When ordering, remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Definitions Electric Defrost Timer Initiates and terminates defrost cycles based on a predetermined time schedule. Lockout Relay Prevents the electric defrost heaters from energizing when the compressor is in operation. Not available on electric defrost timer only options. Fan Contactor Carries amperage load for evaporator fan motors. Heater Contactor Carries amperage load for evaporator electric defrost heaters. InterLink Smart Defrost Kit (SDK) The InterLink SDK is a revolutionary product that is designed to be used on any electric defrost walk-in freezer system with an electro-mechanical defrost timer set for three or more scheduled defrosts per day. The InterLink SDK accurately estimates frost accumulation on the evaporator coil and decides if it can skip the preprogrammed defrost period that is set on the defrost timer. This helps eliminate unneeded defrost cycles, saving energy and increasing product integrity Option Code Description s Used On Notes DFT.002 Defrost Timer - Electric ZRN: X6/L6-562 DFT.007 Electric Defrost Kit ZRN: X6/L6 DFT DFT DFT DFT DEF DEF DEF DEF SDK.001 Electric Defrost Kit (Low Amps) Electric Defrost Kit (Low Amps) Electric Defrost Kit (High Amps) Electric Defrost Kit (High Amps) Fuses for electric defrost kits (Low Amps) Fuses for electric defrost kits (Low Amps) Fuses for electric defrost kits (High Amps) Fuses for electric defrost kits (High Amps) InterLink Smart Defrost Kit SRN: & (460V); ZRN: (230V) & (460V) SRN: (230V); ZRN: M6 (230V) SRN: 0150H2B, 0199M6B, , (460V); ZRN: 0750L6 (230V), M6/L6 (460V) SRN: (230V), ; ZRN: M6 (230V), L6 (230V), M6 (460V) Includes (1) electric defrost timer, (1) heater & (1) fan contactors, and (1) lockout relay. Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Includes (1) electric defrost timer, (1 or 2) heater & (1) fan contactors, terminal strip Adder SRN: ; ZRN: M6, L6-408 SRN: ; ZRN: M6-578 SRN: 0150H2B, 0199M6B, ; ZRN: 0750L6-408 SRN: ; ZRN: M6, L6-578 All Can not be used alone. Must also select a electric defrost timer or electric defrost kit , , s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

192 Remote Compressor Units ¾ - 22 HP Shipped-Loose Accessories A wide range of shipped-loose accessories are available to order. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Mechancial Options Description s Used On Notes Two Tier Rack (Small) , , Two Tier Rack (Large) ,453 Crankcase Pressure Regulator (CPR) Valves A selection program must be used to pick the proper valve. The selection program requires the following inputs: system capacity, suction temperature, and maximum holding temperature. Not available for use on Beacon II Outdoor units. Should not be used with MOP type expansion valves in unit coolers. Please contact your local Sales Representative or Account Engineer for assistance. Size Part Number 5/8" /8" /8" /8" 4227W 1, /8" 4262Q 2,669 Section 2 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 187

193 PRO³ Packaged Refrigeration System Top Mount Overview Features and Benefits Section 2 Product Description The PRO³ Top Mount packaged refrigeration system, designed to maximize storage space inside walk-in coolers and freezers, is ideal for small- to medium-sized restaurant and convenience store applications where holding temperature is the primary goal. The system combines evaporator and condensing unit into one unit expediting installation time and reducing refrigerant charge saving time, money, and energy. The reduced refrigerant charge, compared to comparable split systems, and availability of EC motors, for increased energy efficiency, makes this product line qualified to be included in the E Solutions product portfolio. Certifications Ease of Installation and Service Installation takes a fraction of the time required for a split system: no piping or loose components to install, refrigerant is pre-charged at factory and a field superheat adjustment is not required (see installation manual for more information) No drain line required on indoor models - come standard with a condensate evaporation pan Flexible design allows for multiple installation methods: optimized for indoor use, but outdoor models available with weatherhood installed. Outdoor models also come with: crankcase heater, drain line heater and fan-cycling for head pressure control Maximizes storage area in a cooler or freezer: evaporator grill mounts flush on a standard 4 or a recessed 5 1/2 ceiling panel Ease of Use System is factory-assembled, evacuated, charged, run-tested and wired; no additional components or refrigerant charging required; most models come with a 26 power cord ready to plug-in Controls preset for typical applications: +38 F for high temp. coolers, +35 F for medium temp. coolers, -10 F for freezers and are easy to adjust Reliable & Durable Electronic control provides accurate temperature control Liquid-line filter drier (medium and large cabinet only) Two-year parts warranty Energy Efficient & Environmentally Friendly Optional EC motors available for evaporator section only Reduced refrigerant charge: system uses approximately 10 percent* of refrigerant required for a comparable split system * Results may vary. Estimate based on a typical 25-foot refrigerant line length. Nomenclature 188 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

194 PRO³ Packaged Refrigeration System Top Mount Standard s Pricing Standard Application Location Voltage Evap Fan Motor Type 001Medium & High Temperature - Air Defrost - Cooler Applications (R-404A) Plug Supplied Matching NEMA Receptacle Cabinet Size PTN026H6AE 5,747 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN026H6AH 5,417 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN031H6AE 6,316 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN031H6AH 5,913 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN042H6AE 6,547 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN042H6AH 6,441 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN050H6AE 8,571 Indoor 115/1/60 EC Motor Yes 5-20R Medium PTN050H6AH 8,200 Indoor 115/1/60 PSC Motor Yes 5-20R Medium PTN050H6BE 8,578 Indoor /1/60 EC Motor Yes 6-15R Medium PTN050H6BH 8,436 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN067H6BE 9,805 Indoor /1/60 EC Motor Yes 6-15R Medium PTN067H6BH 8,704 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN076H6BE 10,631 Indoor /1/60 EC Motor Yes 6-15R Medium PTN076H6BH 9,754 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN104H6BE 12,476 Indoor /1/60 EC Motor Yes 6-20R Large PTN104H6BH 10,710 Indoor /1/60 PSC Motor Yes 6-20R Large PTN104H6CE 11,693 Indoor /3/60 EC Motor - - Large PTN104H6CH 10,627 Indoor /3/60 PSC Motor - - Large PTN133H6BE 13,987 Indoor /1/60 EC Motor Yes 6-20R Large PTN133H6BH 12,075 Indoor /1/60 PSC Motor Yes 6-20R Large PTN133H6CE 12,845 Indoor /3/60 EC Motor - - Large PTN133H6CH 11,805 Indoor /3/60 PSC Motor - - Large PTT050H6BE 9,712 Outdoor /1/60 EC Motor - - Medium PTT050H6BH 9,297 Outdoor /1/60 PSC Motor - - Medium PTT067H6BE 10,802 Outdoor /1/60 EC Motor - - Medium PTT067H6BH 9,948 Outdoor /1/60 PSC Motor - - Medium PTT076H6BE 11,578 Outdoor /1/60 EC Motor - - Medium PTT076H6BH 10,687 Outdoor /1/60 PSC Motor - - Medium PTT104H6BE 13,035 Outdoor /1/60 EC Motor - - Large PTT104H6BH 11,816 Outdoor /1/60 PSC Motor - - Large PTT104H6CE 12,993 Outdoor /3/60 EC Motor - - Large PTT104H6CH 11,802 Outdoor /3/60 PSC Motor - - Large PTT133H6BE 14,292 Outdoor /1/60 EC Motor - - Large PTT133H6BH 13,179 Outdoor /1/60 PSC Motor - - Large PTT133H6CE 14,208 Outdoor /3/60 EC Motor - - Large PTT133H6CH 12,957 Outdoor /3/60 PSC Motor - - Large Section 2 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Need help selecting a model? Please contact your local Sales Representative or Account Engineer for assistance. s Effective January 1 st s and specifications subject to change without notice. 189

195 PRO³ Packaged Refrigeration System Top Mount Standard s Pricing Section 2 Standard Application Location Voltage 002Medium Temperature - Electric Defrost - Cooler Applications (R-404A) Evap Fan Motor Type Plug Supplied Matching NEMA Receptacle Cabinet Size PTN024M6AE 5,832 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN024M6AH 5,501 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN029M6AE 6,403 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN029M6AH 5,998 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN040M6AE 6,736 Indoor 115/1/60 EC Motor Yes 5-20R Small PTN040M6AH 6,629 Indoor 115/1/60 PSC Motor Yes 5-20R Small PTN047M6AE 8,755 Indoor 115/1/60 EC Motor Yes 5-20R Medium PTN047M6AH 8,383 Indoor 115/1/60 PSC Motor Yes 5-20R Medium PTN047M6BE 9,214 Indoor /1/60 EC Motor Yes 6-15R Medium PTN047M6BH 8,520 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN063M6BE 9,946 Indoor /1/60 EC Motor Yes 6-15R Medium PTN063M6BH 8,741 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN072M6BE 10,769 Indoor /1/60 EC Motor Yes 6-15R Medium PTN072M6BH 9,891 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN099M6BE 12,901 Indoor /1/60 EC Motor Yes 6-20R Large PTN099M6BH 12,137 Indoor /1/60 PSC Motor Yes 6-20R Large PTN099M6CE 12,595 Indoor /3/60 EC Motor - - Large PTN099M6CH 12,030 Indoor /3/60 PSC Motor - - Large PTN128M6BE 14,487 Indoor /1/60 EC Motor Yes 6-20R Large PTN128M6BH 12,773 Indoor /1/60 PSC Motor Yes 6-20R Large PTN128M6CE 13,928 Indoor /3/60 EC Motor - - Large PTN128M6CH 12,691 Indoor /3/60 PSC Motor - - Large PTT047M6BE 9,832 Outdoor /1/60 EC Motor - - Medium PTT047M6BH 9,418 Outdoor /1/60 PSC Motor - - Medium PTT063M6BE 11,103 Outdoor /1/60 EC Motor - - Medium PTT063M6BH 10,074 Outdoor /1/60 PSC Motor - - Medium PTT072M6BE 11,686 Outdoor /1/60 EC Motor - - Medium PTT072M6BH 10,825 Outdoor /1/60 PSC Motor - - Medium PTT099M6BE 13,298 Outdoor /1/60 EC Motor - - Large PTT099M6BH 12,064 Outdoor /1/60 PSC Motor - - Large PTT099M6CE 13,245 Outdoor /3/60 EC Motor - - Large PTT099M6CH 12,058 Outdoor /3/60 PSC Motor - - Large PTT128M6BE 14,576 Outdoor /1/60 EC Motor - - Large PTT128M6BH 13,469 Outdoor /1/60 PSC Motor - - Large PTT128M6CE 14,481 Outdoor /3/60 EC Motor - - Large PTT128M6CH 13,231 Outdoor /3/60 PSC Motor - - Large 190 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Need help selecting a model? Please contact your local Sales Representative or Account Engineer for assistance. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

196 PRO³ Packaged Refrigeration System Top Mount Standard s Pricing Standard Application Location Voltage 003Low Temperature - Electric Defrost - Freezer Applications (R-404A) Evap Fan Motor Type Plug Supplied Matching NEMA Receptacle Cabinet Size PTN021L6AE 9,839 Indoor 115/1/60 EC Motor Yes 5-20R Medium PTN021L6AH 9,431 Indoor 115/1/60 PSC Motor Yes 5-20R Medium PTN021L6BE 9,865 Indoor /1/60 EC Motor Yes 6-15R Medium PTN021L6BH 9,431 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN031L6BE 11,231 Indoor /1/60 EC Motor Yes 6-15R Medium PTN031L6BH 10,316 Indoor /1/60 PSC Motor Yes 6-15R Medium PTN044L6BE 12,796 Indoor /1/60 EC Motor Yes 6-20R Medium PTN044L6BH 11,771 Indoor /1/60 PSC Motor Yes 6-20R Medium PTN052L6BE 14,632 Indoor /1/60 EC Motor - - Large PTN052L6BH 13,210 Indoor /1/60 PSC Motor - - Large PTN052L6CE 14,627 Indoor /3/60 EC Motor - - Large PTN052L6CH 13,210 Indoor /3/60 PSC Motor - - Large PTN069L6BE 15,624 Indoor /1/60 EC Motor - - Large PTN069L6BH 14,126 Indoor /1/60 PSC Motor - - Large PTN069L6CE 15,611 Indoor /3/60 EC Motor - - Large PTN069L6CH 14,126 Indoor /3/60 PSC Motor - - Large PTT021L6BE 11,133 Outdoor /1/60 EC Motor - - Medium PTT021L6BH 10,676 Outdoor /1/60 PSC Motor - - Medium PTT031L6BE 12,644 Outdoor /1/60 EC Motor - - Medium PTT031L6BH 11,697 Outdoor /1/60 PSC Motor - - Medium PTT044L6BE 14,415 Outdoor /1/60 EC Motor - - Medium PTT044L6BH 13,347 Outdoor /1/60 PSC Motor - - Medium PTT052L6BE 16,408 Outdoor /1/60 EC Motor - - Large PTT052L6BH 14,936 Outdoor /1/60 PSC Motor - - Large PTT052L6CE 16,395 Outdoor /3/60 EC Motor - - Large PTT052L6CH 14,936 Outdoor /3/60 PSC Motor - - Large PTT069L6BE 17,532 Outdoor /1/60 EC Motor - - Large PTT069L6BH 15,988 Outdoor /1/60 PSC Motor - - Large PTT069L6CE 17,522 Outdoor /3/60 EC Motor - - Large PTT069L6CH 15,988 Outdoor /3/60 PSC Motor - - Large Section 2 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Need help selecting a model? Please contact your local Sales Representative or Account Engineer for assistance. s Effective January 1 st s and specifications subject to change without notice. 191

197 PRO³ Packaged Refrigeration System Side Mount Overview Section 2 Product Description The PRO³ Side Mount packaged refrigeration system, designed to maximize storage space inside walkin coolers and freezers and optimized for outdoor applications, is ideal for small- to medium-sized restaurant and convenience store applications where maximum airflow is essential for pulling down the temperature of foods or beverages. The system combines evaporator and condensing unit into one unit expediting installation time and reducing refrigerant charge saving time, money, and energy. The reduced refrigerant charge, compared to comparable split systems, and availability of EC motors, for increased energy efficiency, makes this product line qualified to be included in the E Solutions product portfolio. Certifications Features and Benefits Ease of Installation and Service Installation takes a fraction of the time required for a split system: refrigerant is pre-charged at factory, superheat adjustment is not required and unit slides into slots in standard walk-in panel (see installation manual for more information) Designed for simple serviceability: the condensing unit section s cabinet door can be quickly removed; in addition, the electrical box is located outside the cabinet for easy access Flexible design allows for multiple installation methods: Optimized for outdoor use, but can be used indoors as well (with drain connection) Lifting lugs and hanging brackets in evaporating section allow for easy installation Ease of Use System is factory-assembled, evacuated, charged, run-tested and wired; no additional components required Controls preset for typical applications: +38 F for high temp. coolers, +35 F for medium temp. coolers, -10 F for freezers and are easy to adjust Performance Maximized airflow: evaporator placement in walk-in box with pull through fans Suitable for temperature pull-down and holding temperature Increased condenser capacity, by avoiding compressor heat Improved tolerance in high-ambient conditions Electric defrost in medium temperature models, allowing for maximum performance in storage applications just above 32 F Fan-cycling for head pressure control Crankcase heater Drain line heater Reliable & Durable Electronic microprocessor control provides accurate temperature control Liquid-line filter drier Two-year parts warranty Energy Efficient & Environmentally Friendly Optional EC motors available for evaporator section only Reduced refrigerant charge: the PRO³ Side Mount packaged refrigeration system uses approximately 10 percent* of refrigerant required for a comparable split system * Results may vary. Estimate based on a typical 25-foot refrigerant line length. Nomenclature 192 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

198 PRO³ Packaged Refrigeration System Side Mount Standard s Pricing Standard Application Location Voltage 001Medium & High Temperature - Air Defrost - Cooler Applications (R-404A) Evap Fan Motor Type Cabinet Size PST070H6BE 10,037 Outdoor /1/60 EC Motor Small PST070H6BH 9,660 Outdoor /1/60 PSC Motor Small PST090H6BE 10,605 Outdoor /1/60 EC Motor Small PST090H6BH 10,226 Outdoor /1/60 PSC Motor Small PST131H6BE 12,120 Outdoor /1/60 EC Motor Large PST131H6BH 11,363 Outdoor /1/60 PSC Motor Large PST147H6BE 13,257 Outdoor /1/60 EC Motor Large PST147H6BH 12,500 Outdoor /1/60 PSC Motor Large 002Medium Temperature - Electric Defrost - Cooler Applications (R-404A) PST066M6BE 10,492 Outdoor /1/60 EC Motor Small PST066M6BH 10,113 Outdoor /1/60 PSC Motor Small PST086M6BE 11,059 Outdoor /1/60 EC Motor Small PST086M6BH 10,682 Outdoor /1/60 PSC Motor Small PST124M6BE 12,575 Outdoor /1/60 EC Motor Large PST124M6BH 11,818 Outdoor /1/60 PSC Motor Large PST141M6BE 13,711 Outdoor /1/60 EC Motor Large PST141M6BH 12,954 Outdoor /1/60 PSC Motor Large 003Low Temperature - Electric Defrost - Freezer Applications (R-404A) PST034L6BE 12,309 Outdoor /1/60 EC Motor Small PST034L6BH 11,931 Outdoor /1/60 PSC Motor Small PST051L6BE 13,446 Outdoor /1/60 EC Motor Small PST051L6BH 13,068 Outdoor /1/60 PSC Motor Small PST057L6BE 14,961 Outdoor /1/60 EC Motor Large PST057L6BH 14,204 Outdoor /1/60 PSC Motor Large PST077L6BE 16,098 Outdoor /1/60 EC Motor Large PST077L6BH 15,341 Outdoor /1/60 PSC Motor Large Section 2 Rev. 01/18 Federal Regulation Requires EC Motors! Energy Independence and Security Act of 2007 (H.R. 6) Walk-Ins manufactured on or after 01/01/2009 and under 3,000 square feet in area with single phase evaporator fan motors less than 1 HP and less than 460V must be EC motors. Need help selecting a model? Please contact your local Sales Representative or Account Engineer for assistance. s Effective January 1 st s and specifications subject to change without notice. 193

199 Air-Cooled Condensers 1-26 Ton Product Description Direct drive air-cooled condensers, available from 1 through 26 ton models, are the industry standard for remote air-cooled applications. They are designed for efficient performance and low maintenance and are great for many applications. Standard Features Overview Ease of Installation & Service Weatherproof junction box with motor leads terminating for single-point field wiring Reliable & Durable Heavy gauge smooth aluminum cabinet for long life and attractive appearance Coated steel fan guards Internally protected, permanently lubricated ball bearing motors with automatic reset Performance Fully baffled fan sections to provide structural strength and prevent fan windmillng in the off cycle PSC motors come standard to help save on energy costs Versatile Horizontal or vertical air discharge Multicircuiting at no additional charge Certifications Section 3 Nomenclature 194 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

200 Air-Cooled Condensers 1-26 Ton Configurable s & Options Pricing Configurable s, Factory-Installed Options, & s Specify model motor voltage and type at time of order /1/60 motors may be field converted to 230/3/60 power. Variable speed motor is on the header fan only; All other motors in a 1x2 or 1x3 are fixed speed motors that cycle on or off as needed. Must have variable speed controller (customer supplied or select factory-installed option). Ambient fan cycling is included in the factory-installed variable speed controller package. Standard Control Circuit Voltage is 230V unless otherwise specified. 24V & 115V are available at no additional cost. Specify control circuit voltage when ordering. Fan cycling pricing does not include control circuit transformer for 460V or 575V units. If needed, transformer can be ordered from ship-loose accessories. Configurable 1 PH Amb /1/60 with PSC Motors Factory-Installed Options Adders Fan Cycling Options Electrical Options Coil Coatings 3 PH Amb. 1 PH Press. 3 PH Press. Ind. Motor Fuses Sealtite Wiring Var Sp Controller Guard Coated Fins ElectroFin Coil Bronz-Glow Coating DVT001 2, Call Factory Call Factory DVT002 2, Call Factory Call Factory DVT003 3, Call Factory Call Factory DVT005 5, Call Factory Call Factory DVT008 7, Call Factory Call Factory DVT010 8, ,006 1, Call Factory Call Factory DVT012 10, ,006 1, Call Factory Call Factory DVT014 11, ,006 1, Call Factory Call Factory DVT016 12, ,006 1, Call Factory Call Factory DVT021 14, ,205-1,247 1,369-1,106 Call Factory Call Factory DVT023 14, ,205-1,247 1,369-1,260 Call Factory Call Factory DVT026 16, ,205-1,247 1,369-1,429 Call Factory Call Factory /1/60 with Variable Speed Motor DVT005SM 6, , Call Factory Call Factory DVT008SM 7, , Call Factory Call Factory DVT010SM 9, Call Factory - 1,006 1,327 2, Call Factory Call Factory DVT012SM 10, Call Factory - 1,006 1,327 2, Call Factory Call Factory DVT014SM 11, Call Factory - 1,006 1,327 2, Call Factory Call Factory DVT016SM 13, Call Factory - 1,006 1,327 2, Call Factory Call Factory DVT021SM 14, Call Factory - 1,247 1,369 2,282 1,106 Call Factory Call Factory DVT023SM 15, Call Factory - 1,247 1,369 2,282 1,260 Call Factory Call Factory DVT026SM 16, Call Factory - 1,247 1,369 2,282 1,429 Call Factory Call Factory /3/60 with Polyphase Motors DVT005 6, Call Factory Call Factory DVT008 7, Call Factory Call Factory DVT010 9,570-1,319-1,751 1,006 1, Call Factory Call Factory DVT012 10,554-1,319-1,751 1,006 1, Call Factory Call Factory DVT014 11,992-1,319-1,751 1,006 1, Call Factory Call Factory DVT016 13,094-1,319-1,751 1,006 1, Call Factory Call Factory Section 3 Rev. 01/18 Notes: 1. For selection or sizing assistance, use Heatcraft s New ProSelect software or contact your local your Sales Representative or Account Engineer. 2. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 195

201 Air-Cooled Condensers 1-26 Ton Configurable s & Options Pricing Configurable s, Factory-Installed Options, & s Specify model motor voltage and type at time of order /1/60 motors may be field converted to 230/3/60 power. Variable speed motor is on the header fan only; All other motors in a 1x2 or 1x3 are fixed speed motors that cycle on or off as needed. Must have variable speed controller (customer supplied or select factory-installed option). Ambient fan cycling is included in the factory-installed variable speed controller package. Standard Control Circuit Voltage is 230V unless otherwise specified. 24V & 115V are available at no additional cost. Specify control circuit voltage when ordering. Fan cycling pricing does not include control circuit transformer for 460V or 575V units. If needed, transformer can be ordered from ship-loose accessories. Section 3 Configurable 1 PH Amb. Factory-Installed Options Adders Fan Cycling Options Electrical Options Coil Coatings 3 PH Amb. 1 PH Press. 3 PH Press. Ind. Motor Fuses Sealtite Wiring Var Sp Controller Guard Coated Fins ElectroFin Coil Bronz-Glow Coating DVT021 15,288-1,627-2,108 1,247 1,369-1,106 Call Factory Call Factory DVT023 15,694-1,627-2,108 1,247 1,369-1,260 Call Factory Call Factory DVT026 17,060-1,627-2,108 1,247 1,369-1,429 Call Factory Call Factory /3/60 with Variable Speed Motor DVT010SM 10, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT012SM 11, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT014SM 12, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT016SM 13, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT021SM 15, Call Factory 1,247 1,369 2,282 1,106 Call Factory Call Factory DVT023SM 16, Call Factory 1,247 1,369 2,282 1,260 Call Factory Call Factory DVT026SM 17, Call Factory 1,247 1,369 2,282 1,429 Call Factory Call Factory /3/60 with Polyphase Motors DVT005 6, Call Factory Call Factory DVT008 7, Call Factory Call Factory DVT010 9,570-1,319-1,751 1,006 1, Call Factory Call Factory DVT012 10,554-1,319-1,751 1,006 1, Call Factory Call Factory DVT014 11,992-1,319-1,751 1,006 1, Call Factory Call Factory DVT016 13,094-1,319-1,751 1,006 1, Call Factory Call Factory DVT021 15,288-1,627-2,108 1,247 1,369-1,106 Call Factory Call Factory DVT023 15,694-1,627-2,108 1,247 1,369-1,260 Call Factory Call Factory DVT026 17,060-1,627-2,108 1,247 1,369-1,429 Call Factory Call Factory /3/60 with Variable Speed Motor DVT010SM 10, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT012SM 11, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT014SM 12, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT016SM 13, Call Factory 1,006 1,327 2, Call Factory Call Factory DVT021SM 15, Call Factory 1,247 1,369 2,282 1,106 Call Factory Call Factory DVT023SM 16, Call Factory 1,247 1,369 2,282 1,260 Call Factory Call Factory DVT026SM 17, Call Factory 1,247 1,369 2,282 1,429 Call Factory Call Factory Notes: 1. For selection or sizing assistance, use Heatcraft s New ProSelect software or contact your local your Sales Representative or Account Engineer. 2. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. 196 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

202 Air-Cooled Condensers 1-26 Ton Configurable s & Options Pricing Configurable s, Factory-Installed Options, & s Specify model motor voltage and type at time of order /1/60 motors may be field converted to 230/3/60 power. Variable speed motor is on the header fan only; All other motors in a 1x2 or 1x3 are fixed speed motors that cycle on or off as needed. Must have variable speed controller (customer supplied or select factory-installed option). Ambient fan cycling is included in the factory-installed variable speed controller package. Standard Control Circuit Voltage is 230V unless otherwise specified. 24V & 115V are available at no additional cost. Specify control circuit voltage when ordering. Fan cycling pricing does not include control circuit transformer for 460V or 575V units. If needed, transformer can be ordered from ship-loose accessories. Configurable 1 PH Amb /3/60 with Polyphase Motors Factory-Installed Options Adders Fan Cycling Options Electrical Options Coil Coatings 3 PH Amb. 1 PH Press. 3 PH Press. Ind. Motor Fuses Sealtite Wiring Var Sp Controller Guard Coated Fins ElectroFin Coil Bronz-Glow Coating DVT005 6, Call Factory Call Factory DVT008 7, Call Factory Call Factory DVT010 10,366-1,319-1,751-1, Call Factory Call Factory DVT012 11,350-1,319-1,751-1, Call Factory Call Factory DVT014 12,787-1,319-1,751-1, Call Factory Call Factory DVT016 13,888-1,319-1,751-1, Call Factory Call Factory DVT021 16,482-1,627-2,108-1,369-1,106 Call Factory Call Factory DVT023 16,886-1,627-2,108-1,369-1,260 Call Factory Call Factory DVT026 18,253-1,627-2,108-1,369-1,429 Call Factory Call Factory Notes: 1. For selection or sizing assistance, use Heatcraft s New ProSelect software or contact your local your Sales Representative or Account Engineer. 2. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information Ton Can t Find An Option or Accessory? Ship-Loose Accessories Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 3 Part Number Description s Used On Notes Discharge Air Gravity Damper 1x1 1,324 Includes 1 damper per fan cell Discharge Air Gravity Dampers 1x2 2,648 Includes 1 damper per fan cell Discharge Air Gravity Dampers 1x3 3,972 Includes 1 damper per fan cell R Control Circuit Transformer ALL Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 197

203 Air-Cooled Condensers Ton Overview Section 3 Product Description These air-cooled condensers feature improved energy efficiency and low sound levels sought after by the supermarket and grocery industry. Traditional condensers using 1140 RPM motors offer high capacities, but cannot meet the low sound and energy efficiency standards demanded today by this industry. High capacities for operation along with the low sound and energy efficiency requirements are brought together in these units for a great fit for many applications. Choosing a model with the patented QuietEdge Fan Blade or Variable Speed EC motors makes this product qualified to be included in the E Solutions product portfolio. Certifications Standard Features 10 fins per inch spacing standard. 8, 12, and 14 fins per inch spacing available as an option. Floating Tube coil design virtually eliminates tube sheet leaks Internal baffles provided between all fan cells Condensers up to 3 fans in length use 3/8 diameter tube to minimize refrigerant charge.condensers 4 or more fans in length use 1/2" diameter tube to minimize refrigerant pressure drop Coated steel fan guards Weather resistant control panel with factory-mounted door interrupt disconnect switch 2-year warranty on product and 5-year warranty on Floating Tube s with Rail-Mount Variable Speed EC Motors (VSEC) 830 or 1140 RPM maximum speeds, with capacities matching 830 or 1140 RPM fixed speed motor options 830 RPM Rail Mounted option meets California Title 24 energy efficiency standard s with Venturi-Mount Variable Speed EC Motors (VSEC) EC motor, swept fan blade and venturi incorporating integrated variable speed technology Broad capacity range from 16 to 264 tons Aluminum housing for an attractive appearance and corrosion protection, with painted galvanized steel, or galvanized steel as an option Side access panels for ease of cleaning coils 3-year warranty on EC motors s with 830 or 540 RPM Fixed Speed Motors Direct drive fan motors in 830 or 540 RPM The patented QuietEdge fan blade provides an unprecedented sound level of 49.6 dba ( ft.) Patented ServiceEase motor mount feature, allows for ease of motor service and reduces likelihood of damage to the coils during servicing Condenser coils incorporate the latest advancements in coil technology to provide maximum capacity Broader product range to address all applications capacities ranging from 11 to 225 nominal tons Galvanized steel housing High efficiency, three-phase fan motors with ball bearings and internal overload protection s with 1140 RPM Fixed Speed Motors Direct drive fan motors Patented ServiceEase motor mount New, high efficiency condenser coil designed for optimum performance Expanded product range from 15 to 249 nominal tons Galvanized steel housing High efficiency, three-phase fan motors with ball bearings and internal overload protection Nomenclature 198 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

204 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable <001>s with VSEC Motors by Motor Voltage /3/60 460/3/60 575/3/60 Fan Config. BNES01A008 17,458 17,458-1x1 - BNES01A009 19,330 19,330-1x1 - BNES02A011 29,888 29,888-1x2 - BNES02A015 34,265 34,265-1x2 - BNES02A018 37,471 37,471-1x2 - BNES03A023 51,444 51,444-1x3 - BNES03A027 56,266 56,266-1x3 - BNES04A031 69,474 69,474-1x4 - BNES04A036 75,016 75,016-1x4 - BNES05A039 86,658 86,658-1x5 - BNES05A047 95,337 95,337-1x5 - BNES06A , ,404-1x6 - BNES07A , ,242-1x7 - BNED04A023 58,901 58,901-2x2 - BNED04A031 68,598 68,598-2x2 - BNED04A036 75,016 75,016-2x2 - BNED06A , ,875-2x3 - BNED06A , ,518-2x3 - Notes BNED08A , ,555-2x4 has oversized electrical box. BNED08A , ,419-2x4 has oversized electrical box. BNED10A , ,636-2x5 has oversized electrical box. BNED10A , ,030-2x5 has oversized electrical box. BNED12A , ,179-2x6 has oversized electrical box. BNED14A , ,858-2x7 has oversized electrical box. <001>s with 540 RPM (0.5HP) Motors BNQS01A005 8,015 8,015-1x1 - BNQS01A006 9,601 9,601-1x1 - BNQS02A008 13,263 13,263-1x2 - BNQS02A010 17,783 17,783-1x2 - BNQS02A011 19,956 19,956-1x2 - BNQS03A016 27,761 27,761-1x3 - BNQS03A017 30,898 30,898-1x3 - BNQS04A021 37,592 37,592-1x4 - BNQS04A023 41,778 41,778-1x4 - BNQS05A026 47,486 47,486-1x5 - BNQS05A029 52,717 52,717-1x5 - BNQS06A034 63,678 63,678-1x6 - Section 3 Rev. 01/18 Notes: For sizing and selection assistance, use Heatcraft's new ProSelect software or contact your local Sales Representative or Account Engineer. s Effective January 1 st s and specifications subject to change without notice. 199

205 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Section 3 Configurable by Motor Voltage /3/60 460/3/60 575/3/60 Fan Config. BNQS07A042 77,428 77,428-1x7 - BNQD04A016 28,532 28,532-2x2 - BNQD04A021 37,592 37,592-2x2 - BNQD04A023 41,778 41,778-2x2 - BNQD06A031 57,319 57,319-2x3 - BNQD06A034 63,678 63,678-2x3 - Notes BNQD08A041 77,475 77,475-2x4 has oversized electrical box. BNQD08A046 85,906 85,906-2x4 has oversized electrical box. BNQD10A052 97,287 97,287-2x5 has oversized electrical box. BNQD10A , ,807-2x5 has oversized electrical box. BNQD12A , ,628-2x6 has oversized electrical box. BNQD14A , ,148-2x7 has oversized electrical box. <002>s with 830 RPM (1.0HP) Motors BNXS01A006 8,057 8,057-1x1 - BNXS01A008 9,749 9,749-1x1 - BNXS02A010 13,061 13,061-1x2 - BNXS02A013 17,881 17,881-1x2 - BNXS02A015 20,803 20,803-1x2 - BNXS03A020 27,458 27,458-1x3 - BNXS03A023 31,862 31,862-1x3 - BNXS04A026 37,035 37,035-1x4 - BNXS04A030 42,877 42,877-1x4 - BNXS05A033 46,583 46,583-1x5 - BNXS05A038 53,890 53,890-1x5 - BNXS06A045 64,967 64,967-1x6 - BNXS07A052 74,589 74,589-1x7 - BNXD04A020 27,329 27,329-2x2 - BNXD04A026 37,020 37,020-2x2 - BNXD04A030 42,894 42,894-2x2 - BNXD06A039 56,141 56,141-2x3 - BNXD06A045 64,950 64,950-2x3 - BNXD08A052 75,606 75,606-2x4 has oversized electrical box. BNXD08A061 87,357 87,357-2x4 has oversized electrical box. BNXD10A066 94,730 94,730-2x5 has oversized electrical box. BNXD10A , ,415-2x5 has oversized electrical box. BNXD12A , ,473-2x6 has oversized electrical box. BNXD14A , ,746-2x7 has oversized electrical box. Notes: For sizing and selection assistance, use Heatcraft s new ProSelect software or contact your local Sales Representative or Account Engineer. 200 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

206 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable <003>s with 830 RPM (1.5HP) Motors by Motor Voltage /3/60 460/3/60 575/3/60 Fan Config. BNLS01A007 8,994 8,994 9,225 1x1 - BNLS01A008 10,635 10,635 10,866 1x1 - BNLS02A010 13,487 13,487 13,949 1x2 - BNLS02A014 18,541 18,541 19,003 1x2 - BNLS02A016 21,498 21,498 21,960 1x2 - BNLS03A021 27,818 27,818 28,511 1x3 - BNLS03A024 32,274 32,274 32,967 1x3 - BNLS04A028 37,035 37,035 37,959 1x4 - BNLS04A032 43,006 43,006 43,930 1x4 - BNLS05A035 47,187 47,187 48,342 1x5 - BNLS05A042 55,342 55,342 56,497 1x5 - BNLS06A050 66,350 66,350 67,736 1x6 - BNLS07A055 73,174 73,174 74,791 1x7 - BNLD04A020 26,943 26,943 27,867 2x2 - BNLD04A028 37,036 37,036 37,960 2x2 - BNLD04A032 43,006 43,006 43,930 2x2 - BNLD06A042 55,572 55,572 56,958 2x3 - BNLD06A048 64,456 64,456 65,842 2x3 - Notes BNLD08A056 74,411 74,411 76,259 2x4 has oversized electrical box. BNLD08A065 86,311 86,311 88,159 2x4 has oversized electrical box. BNLD10A071 94,655 94,655 96,965 2x5 has oversized electrical box. BNLD10A , , ,231 2x5 has oversized electrical box. BNLD12A , , ,785 2x6 has oversized electrical box. BNLD14A , , ,881 2x7 has oversized electrical box. <004>s with 1140 RPM (1.5HP) Motors BNHS01A007 9,173 9,173 9,404 1x1 - BNHS01A009 10,992 10,992 11,223 1x1 - BNHS02A011 13,467 13,467 13,929 1x2 - BNHS02A015 17,715 17,715 18,177 1x2 - BNHS02A017 20,830 20,830 21,292 1x2 - BNHS03A022 26,618 26,618 27,311 1x3 - BNHS03A026 31,300 31,300 31,993 1x3 - BNHS04A029 36,346 36,346 37,270 1x4 - BNHS04A034 41,729 41,729 42,653 1x4 - BNHS05A037 45,259 45,259 46,414 1x5 - BNHS05A044 53,683 53,683 54,838 1x5 - Section 3 Rev. 01/18 Notes: For sizing and selection assistance, use Heatcraft s new ProSelect software or contact your local Sales Representative or Account Engineer. s Effective January 1 st s and specifications subject to change without notice. 201

207 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable by Motor Voltage /3/60 460/3/60 575/3/60 Fan Config. BNHS06A053 64,419 64,419 65,805 1x6 - BNHS07A061 74,934 74,934 76,551 1x7 - BNHD04A021 26,085 26,085 27,009 2x2 - BNHD04A029 35,499 35,499 36,423 2x2 - BNHD04A034 41,729 41,729 42,653 2x2 - BNHD06A044 53,227 53,227 54,613 2x3 - BNHD06A051 62,588 62,588 63,974 2x3 - Notes BNHD08A058 71,358 71,358 73,206 2x4 has oversized electrical box. BNHD08A068 83,845 83,845 85,693 2x4 has oversized electrical box. BNHD10A074 90,839 90,839 93,149 2x5 has oversized electrical box. BNHD10A , , ,036 2x5 has oversized electrical box. BNHD12A , , ,984 2x6 has oversized electrical box. BNHD14A , , ,473 2x7 has oversized electrical box. Section 3 Notes: For sizing and selection assistance, use Heatcraft s new ProSelect software or contact your local Sales Representative or Account Engineer. 202 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

208 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable by Motor Voltage /3/60 460/3/60 575/3/60 s with Rail-Mount VSEC (1140 RPM) Motors Fan Config. BNKS01A007 14,973 14,973-1x1 - BNKS01A009 16,829 16,829-1x1 - BNKS02A011 24,961 24,961-1x2 - BNKS02A015 29,300 29,300-1x2 - BNKS02A017 32,479 32,479-1x2 - BNKS03A022 43,996 43,996-1x3 - BNKS03A026 48,776 48,776-1x3 - BNKS04A029 59,536 59,536-1x4 - BNKS04A034 65,030 65,030-1x4 - BNKS05A037 74,238 74,238-1x5 - BNKS05A044 82,840 82,840-1x5 - BNKS06A053 99,408 99,408-1x6 - BNKS07A , ,750-1x7 - BNKD04A021 49,057 49,057-2x2 - BNKD04A029 58,668 58,668-2x2 - BNKD04A034 65,030 65,030-2x2 - BNKD06A044 87,981 87,981-2x3 - BNKD06A051 97,538 97,538-2x3 - Notes BNKD08A , ,696-2x4 has oversized electrical box. BNKD08A , ,447-2x4 has oversized electrical box. BNKD10A , ,797-2x5 has oversized electrical box. BNKD10A , ,039-2x5 has oversized electrical box. BNKD12A , ,188-2x6 has oversized electrical box. BNKD14A , ,872-2x7 has oversized electrical box. s with Rail-Mount VSEC (830 RPM) Motors BNJS01A007 14,919 14,919-1x1 - BNJS01A008 16,722 16,722-1x1 - BNJS02A010 24,967 24,967-1x2 - BNJS02A014 29,547 29,547-1x2 - BNJS02A016 32,679 32,679-1x2 - BNJS03A021 44,356 44,356-1x3 - BNJS03A024 49,068 49,068-1x3 - BNJS04A028 59,743 59,743-1x4 - BNJS04A032 65,413 65,413-1x4 - BNJS05A035 74,817 74,817-1x5 - BNJS05A042 83,338 83,338-1x5 - BNJS06A050 99,988 99,988-1x6 - Section 3 Rev. 01/18 Notes: For sizing and selection assistance, use Heatcraft s new ProSelect software or contact your local Sales Representative or Account Engineer. s Effective January 1 st s and specifications subject to change without notice. 203

209 Air-Cooled Condensers Ton Need to customize? Configurable s Pricing Look on page starting 205 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 209 for condenser fin and coil protection options. Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable by Motor Voltage /3/60 460/3/60 575/3/60 Fan Config. BNJS07A , ,222-1x7 - BNJD04A020 49,314 49,314-2x2 - BNJD04A028 59,130 59,130-2x2 - BNJD04A032 65,413 65,413-2x2 - BNJD06A042 88,684 88,684-2x3 - BNJD06A048 98,099 98,099-2x3 - Notes BNJD08A , ,612-2x4 has oversized electrical box. BNJD08A , ,187-2x4 has oversized electrical box. BNJD10A , ,942-2x5 has oversized electrical box. BNJD10A , ,998-2x5 has oversized electrical box. BNJD12A , ,329-2x6 has oversized electrical box. BNJD14A , ,795-2x7 has oversized electrical box. Section 3 Notes: For sizing and selection assistance, use Heatcraft s new ProSelect software or contact your local Sales Representative or Account Engineer. 204 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

210 Air-Cooled Condensers Ton Can t Find An Option? Options Pricing - Rail-Mounted VSEC s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Motors are /3/60 or 460/3/60. Power outlet is supplied unwired. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Option Code Fan Cycling Options Option Description Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 1x7 2x2 2x3 2x4 2x5 2x6 2x7 FC.019 Proportional Pressure Control 2,176 2,176 2,176 2,176 2,176 2,176 2,176 4,349 4,349 4,349 4,349 4,349 4,349 Electrical Options DISC.002 Fused Disconnect ,191 1,426 1, ,426 1,907 2,384 2,854 3,332 MP.002 Individual Motor Fuses ,191 1,429 1, ,429 1,905 2,382 2,858 3,334 MP.004 Paired Motor Fuses ,190 1,428 1,666 MP.003 Individual Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 3,274 1,891 2,835 3,794 4,742 5,691 6,325 MP.005 Paired Circuit Breakers (230V or 460V) ,411 1,897 2,371 2,845 3,274 MTB.001 Individual Motor Terminal Boards , ,331 1,664 2,250 2,580 MTB.002 Paired Motor Terminal Boards ,158 PO.001 Power Outlet (115V) Mechanical Options CM.004 Aluminum Cabinet ,056 1,320 1,584 1,848 1,056 1,584 2,112 2,640 3,168 3,696 CM.003 Pre-Painted Steel Cabinet ,056 1,320 1,584 1,848 1,056 1,584 2,112 2,640 3,168 3,696 CM.004 Coil Access Panels, Galv ,056 1,320 1,584 1,848 1,056 1,584 2,112 2,640 3,168 3,696 CM.005 Coil Access Panels, Aluminum 530 1,060 1,590 2,120 2,650 3,180 3,710 2,120 3,180 4,240 5,300 6,360 7,420 CM.006 Coil Access Panels, Painted Steel 530 1,060 1,590 2,120 2,650 3,180 3,710 2,120 3,180 4,240 5,300 6,360 7,420 VEN.002 Hinged Venturi 563 1,126 1,689 2,252 2,815 3,378 3,941 2,252 3,378 4,504 5,630 6,756 7,882 LEGS.002 Extended Legs, 30" LEGS.003 Extended Legs, 36" LEGS.004 Extended Legs, 42" LEGS.005 Unit Frame, Std. Legs, 20" 1,684 2,429 3,177 4,550 5,506 6,566 7,332 2,429 3,177 4,550 5,506 6,566 7,626 LEGS.006 Unit Frame, Ext. Legs, 42" 1,801 2,667 3,533 5,024 6,099 7,280 8,135 2,669 3,534 5,024 6,099 7,280 8,460 Section 3 LEGS.007 Paratemp, 20" LEGS.008 Paratemp, Extended Legs, 30" , , LEGS.009 Paratemp, Extended Legs, 36" , , LEGS.010 Paratemp, Extended Legs, 42" , , HM.00X Connection Manifold (shipped-loose) ,223 1,588 1,621 1,787 1,853 2,051 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 205

211 Air-Cooled Condensers Ton Can t Find An Option? Options Pricing - Venturi-Mounted VSEC s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Motors are /3/60 or 460/3/60. Power outlet is supplied unwired. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Section 3 Option Code Fan Cycling Options Option Description Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 1x7 2x2 2x3 2x4 2x5 2x6 2x7 FC.019 Proportional Pressure Control 2,176 2,176 2,176 2,176 2,176 2,176 2,176 4,349 4,349 4,349 4,349 4,349 4,349 Electrical Options DISC.002 Fused Disconnect ,191 1,426 1, ,426 1,907 2,384 2,854 3,332 MP.002 Individual Motor Fuses ,191 1,429 1, ,429 1,905 2,382 2,858 3,334 MP.004 Paired Motor Fuses ,191 1,429 1,667 MP.003 Individual Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 3,274 1,891 2,835 3,794 4,742 5,691 6,325 MP.005 Paired Circuit Breakers (230V or 460V) ,411 1,897 2,371 2,845 3,274 MTB.001 Individual Motor Terminal Boards , ,331 1,664 2,250 2,580 MTB.002 Paired Motor Terminal Boards ,158 PO.001 Power Outlet (115V) Mechanical Options CM.004 Galvanized Cabinet w/ Side Access ,057-1,321-1,585-1,849-1,057-1,585-2,113-2,642-3,170-3,698 LEGS.002 Extended Legs, 30" LEGS.003 Extended Legs, 36" LEGS.004 Extended Legs, 42" LEGS.005 Unit Frame, Std. Legs, 20" 1,684 2,429 3,177 4,550 5,506 6,566 7,332 2,429 3,177 4,550 5,506 6,566 7,626 LEGS.006 Unit Frame, Ext. Legs, 42" 1,801 2,667 3,533 5,024 6,099 7,280 8,135 2,669 3,534 5,024 6,099 7,280 8,460 LEGS.007 Paratemp, 20" LEGS.008 Paratemp, Extended Legs, 30" , , LEGS.009 Paratemp, Extended Legs, 36" , , LEGS.010 Paratemp, Extended Legs, 42" , , HM.00X Connection Manifold (shipped-loose) ,223 1,588 1,621 1,787 1,853 2, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

212 Air-Cooled Condensers Ton Options Pricing - Fixed Speed s Can t Find An Option? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Fans are cycled in pairs on double wide units. Pressure fan cycling and variable speed control options are not available on multi-circuited units. Variable speed motors are not available for 575/3/60. Variable speed motor is on fan closest to header only. Variable speed motors have a full speed RPM of 1140 and are typically used on condensers that have either 1140RPM or 830RPM 1.5HP fixed speed motors. For condensers with 830RPM 1HP or 540RPM motors, contact factory for assistance. Motor circuit breakers are not available on 575V units. Motor terminal boards are not available on units with fan cycling. When ordering toggle switch option, please specify whether switches are to be internally or externally mounted. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Power outlet is supplied unwired. Fan cycling kit does not include control circuit transformer. Optional factory installed control transformers are available to convert 460V or 575V man power supplies to 230V, 115V or 24V control power or 230V main power to 115V or 24V control power. Option Code Option Description Fan Cycling Options (Must Select Fan Cycling and Contactor Option) Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 1x7 2x2 2x3 2x4 2x5 2x6 2x7 FCC.004 Individual Motor Contactors: 230V, 115V, or 24V ,190 1,428 1, ,428 1,904 2,380 2,856 3,332 FCC.001 Paired Motor Contactors: 230V, 115V, or 24V ,190 1,428 1,666 FC.003 Ambient Fan Cycling ,232 1,642 2,051 2,462 2, ,232 1,642 2,051 2,462 2,871 FC.004 Pressure Fan Cycling Mech. w/o Header - 1,379 1,509 2,011 2,515 3,018 3,520 1,379 1,509 2,011 2,515 3,018 3,520 FC.006 Pressure Fan Cycling Mech. w/ Header 1,617 1,746 2,250 2,753 3,256 3,759 4,261 1,746 2,250 2,753 3,256 3,759 4,261 FC.005 Pressure Fan Cycling Elec. w/o Header - 1,431 1,794 2,980 4,166 5,351 6,286 1,431 1,794 2,980 4,166 5,351 6,286 FC.007 Pressure Fan Cycling Elec. w/ Header 1,671 2,032 3,218 4,403 5,590 6,514 7,654 2,032 3,218 4,403 5,590 6,514 7,654 FC.008 Variable Speed with Ambient 2,316 2,627 2,953 3,362 3,773 4,183 4,593 2,627 2,953 3,362 3,773 4,183 4,593 FC.010 Variable Speed with Pressure (Mech.) 2,719 2,919 3,229 3,730 4,236 4,739 5,241 2,919 3,229 3,730 4,236 4,739 5,241 FC.011 Variable Speed with Pressure (Elec.) 2,879 3,189 3,514 4,700 5,886 6,798 7,940 3,189 3,514 4,700 5,886 6,798 7,940 FC.014 Microprocessor Relay Board 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 2,846 FC.015 Microprocessor Relay Board w/ Split ,075 3,075 3,075 3,075 3,075 3,075 Electrical Options CV.002 Control Circuit Transformer: 230V, 115V, or 24V MP.002 Individual Motor Fuses ,191 1,429 1, ,429 1,905 2,382 2,858 3,334 MP.004 Paired Motor Fuses ,191 1,429 1,667 MP.003 Individual Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 3,274 1,897 2,845 3,794 4,742 5,691 6,325 MP.005 Paired Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 3,274 MTB.001 Individual Motor Terminal Boards , ,331 1,664 2,250 2,580 MTB.002 Paired Motor Terminal Boards ,158 FCS.002 Fan Toggle Switches ,191 1,389 FCS.004 Paired Fan Toggle Switches DISC.002 Fused Disconnect ,191 1,426 1, ,426 1,907 2,384 2,854 3,332 COND.001 Sealtite Wiring to Motor Rail ,038 1,301 1,560 1,810 COND.002 Sealtite Wiring to Electrical Box 687 1,377 2,065 2,753 3,440 4,131 4,818 2,753 4,130 5,506 6,618 7,941 9,266 PO.001 Power Outlet (115V) Mechanical Options CM.004 Aluminum Cabinet ,057 1,321 1,585 1,849 1,057 1,585 2,113 2,642 3,170 3,698 CM.003 Pre-Painted Steel Cabinet ,057 1,321 1,585 1,849 1,057 1,585 2,113 2,642 3,170 3,698 CM.004 Coil Access Panels, Galv ,057 1,321 1,585 1,849 1,057 1,585 2,113 2,642 3,170 3,698 CM.005 Coil Access Panels, Aluminum 530 1,060 1,590 2,120 2,650 3,180 3,710 2,120 3,180 4,240 5,300 6,360 7,426 Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 207

213 Air-Cooled Condensers Ton Can t Find An Option? Options Pricing - Fixed Speed s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Fans are cycled in pairs on double wide units. Pressure fan cycling and variable speed control options are not available on multi-circuited units. Variable speed motors are not available for 575/3/60. Variable speed motor is on fan closest to header only. Variable speed motors have a full speed RPM of 1140 and are typically used on condensers that have either 1140RPM or 830RPM 1.5HP fixed speed motors. For condensers with 830RPM 1HP or 540RPM motors, contact factory for assistance. Motor circuit breakers are not available on 575V units. Motor terminal boards are not available on units with fan cycling. When ordering toggle switch option, please specify whether switches are to be internally or externally mounted. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Power outlet is supplied unwired. Fan cycling kit does not include control circuit transformer. Optional factory installed control transformers are available to convert 460V or 575V man power supplies to 230V, 115V or 24V control power or 230V main power to 115V or 24V control power. Option Code Option Description Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 1x7 2x2 2x3 2x4 2x5 2x6 2x7 CM.006 Coil Access Panels, Painted Steel 530 1,060 1,590 2,120 2,650 3,180 3,710 2,120 3,180 4,240 5,300 6,360 7,420 VEN.002 Hinged Venturi 563 1,125 1,688 2,251 2,813 3,376 3,938 2,251 3,376 4,501 5,626 6,752 7,877 LEGS.002 Extended Legs, 30" LEGS.003 Extended Legs, 36" LEGS.004 Extended Legs, 42" LEGS.005 Unit Frame, Std. Legs, 20" 1,684 2,429 3,177 4,550 5,506 6,314 7,332 2,429 3,177 4,550 5,506 6,566 7,626 LEGS.006 Unit Frame, Ext. Legs, 42" 1,801 2,669 3,534 5,027 6,103 7,000 8,135 2,669 3,534 5,027 6,103 7,280 8,460 LEGS.007 Paratemp, 20" LEGS.008 Paratemp, Extended Legs, 30" , , LEGS.009 Paratemp, Extended Legs, 36" , , LEGS.010 Paratemp, Extended Legs, 42" , , HM.00X Connection Manifold (shipped-loose) ,223 1,588 1,621 1,787 1,853 2,051 Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

214 Air-Cooled Condensers Ton Coil Options Pricing - All s Rev. 01/18 Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI s with Venturi-Mount VSEC Motors Adders Guard Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating s Effective January 1 st s and specifications subject to change without notice. Copper Fin Coil BNES01A Standard Call Factory Call Factory Call Factory BNES01A Standard ,222 Call Factory Call Factory Call Factory BNES02A Standard 795 1,591 1,243 Call Factory Call Factory Call Factory BNES02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNES02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNES03A023-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNES03A027-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNES04A031-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNES04A036-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNES05A039-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNES05A047-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory BNES06A056-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNES07A065-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNED04A023-1,589 Standard 1,589 3,182 2,482 Call Factory Call Factory Call Factory BNED04A031-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNED04A036-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNED06A046-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNED06A054-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNED08A062-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNED08A073-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNED10A079-3,977 Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNED10A093-3,977 Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNED12A112-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNED14A129-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory s with 540 RPM (0.5HP) Motors BNQS01A Standard Call Factory Call Factory Call Factory BNQS01A Standard ,222 Call Factory Call Factory Call Factory BNQS02A Standard 795 1,591 1,243 Call Factory Call Factory Call Factory BNQS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNQS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNQS03A016-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNQS03A017-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNQS04A021-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNQS04A023-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNQS05A026-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNQS05A029-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory BNQS06A034-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory 209 Section 3

215 Air-Cooled Condensers Ton Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Section 3 Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating Copper Fin Coil BNQS07A042-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNQD04A016-1,589 Standard 1,589 3,182 2,482 Call Factory Call Factory Call Factory BNQD04A021-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNQD04A023-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNQD06A031-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNQD06A034-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNQD08A041-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNQD08A046-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNQD10A052-3,977 Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNQD10A057-3,977 Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNQD12A069-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNQD14A083-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory s with 830 RPM (1.0HP) Motors BNXS01A Standard Call Factory Call Factory Call Factory BNXS01A Standard ,222 Call Factory Call Factory Call Factory BNXS02A Standard 795 1,591 1,243 Call Factory Call Factory Call Factory BNXS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNXS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNXS03A020-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNXS03A023-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNXS04A026-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNXS04A030-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNXS05A033-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNXS05A038-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory BNXS06A045-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNXS07A052-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNXD04A020-1,589 Standard 1,589 3,182 2,482 Call Factory Call Factory Call Factory BNXD04A026-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNXD04A030-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNXD06A039-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNXD06A045-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNXD08A052-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNXD08A061-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNXD10A066-3,977 Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNXD10A076-3,977 Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNXD12A091-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNXD14A104-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory 210 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

216 Air-Cooled Condensers Ton Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI s with 830 RPM (1.5HP) Motors Adders Guard Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating Copper Fin Coil BNLS01A Standard Call Factory Call Factory Call Factory BNLS01A Standard ,222 Call Factory Call Factory Call Factory BNLS02A Standard 795 1,591 1,243 Call Factory Call Factory Call Factory BNLS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNLS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNLS03A021-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNLS03A024-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNLS04A028-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNLS04A032-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNLS05A035-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNLS05A042-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory BNLS06A050-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNLS07A055-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNLD04A020-1,589 Standard 1,589 3,182 2,482 Call Factory Call Factory Call Factory BNLD04A028-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNLD04A032-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNLD06A042-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNLD06A048-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNLD08A056-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNLD08A065-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNLD10A071-3,977 Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNLD10A083-3,977 Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNLD12A100-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNLD14A110-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory s with 1140 RPM (1.5HP) Motors BNHS01A Standard Call Factory Call Factory Call Factory BNHS01A Standard ,222 Call Factory Call Factory Call Factory BNHS02A Standard 795 1,591 1,243 Call Factory Call Factory Call Factory BNHS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNHS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNHS03A022-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNHS03A026-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNHS04A029-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNHS04A034-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNHS05A037-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNHS05A044-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 211

217 Air-Cooled Condensers Ton Can t Find An Option? Coil Options Pricing - All s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Condenser Fin and Coil Protection Options Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating Copper Fin Coil BNHS06A053-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNHS07A061-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNHD04A021-1,589 Standard 1,589 3,182 2,482 Call Factory Call Factory Call Factory BNHD04A029-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNHD04A034-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNHD06A044-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNHD06A051-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNHD08A058-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNHD08A068-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNHD10A074-3,977 Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNHD10A088-3,977 Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNHD12A106-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNHD14A122-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

218 Air-Cooled Condensers Ton Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI s with Rail-Mount VSEC (1140 RPM) Motors Adders Polyester Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating Copper Fin Coil BNKS01A Standard Call Factory Call Factory Call Factory BNKS01A Standard ,222 Call Factory Call Factory Call Factory BNKS02A Standard 794 1,592 1,243 Call Factory Call Factory Call Factory BNKS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNKS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNKS03A022-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNKS03A026-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNKS04A029-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNKS04A034-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNKS05A037-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNKS05A044-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory BNKS06A053-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNKS07A061-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNKD04A021-1,588 Standard 1,588 3,184 2,482 Call Factory Call Factory Call Factory BNKD04A029-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNKD04A034-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNKD06A044-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNKD06A051-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNKD08A058-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNKD08A068-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNKD10A Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNKD10A Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNKD12A106-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNKD14A122-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory s with Rail-Mount VSEC (830 RPM) Motors BNJS01A Standard Call Factory Call Factory Call Factory BNJS01A Standard ,222 Call Factory Call Factory Call Factory BNJS02A Standard 794 1,592 1,243 Call Factory Call Factory Call Factory BNJS02A Standard 796 1,591 1,490 Call Factory Call Factory Call Factory BNJS02A Standard 796 1,591 2,420 Call Factory Call Factory Call Factory BNJS03A021-1,193 Standard 1,193 2,387 2,748 Call Factory Call Factory Call Factory BNJS03A024-1,193 Standard 1,193 2,387 3,923 Call Factory Call Factory Call Factory BNJS04A028-1,591 Standard 1,591 3,181 4,145 Call Factory Call Factory Call Factory BNJS04A032-1,591 Standard 1,591 3,181 5,528 Call Factory Call Factory Call Factory BNJS05A035-1,988 Standard 1,988 3,977 5,174 Call Factory Call Factory Call Factory BNJS05A042-1,988 Standard 1,988 3,977 6,897 Call Factory Call Factory Call Factory Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 213

219 Air-Cooled Condensers Ton Can t Find An Option? Coil Options Pricing - All s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Condenser Fin and Coil Protection Options Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Polyester Fin Protection Coil Protection Options ElectroFin Coils Bronz-Glow Coating Copper Fin Coil BNJS06A050-2,387 Standard 2,387 4,773 8,280 Call Factory Call Factory Call Factory BNJS07A055-2,784 Standard 2,784 5,568 9,663 Call Factory Call Factory Call Factory BNJD04A020-1,588 Standard 1,588 3,184 2,482 Call Factory Call Factory Call Factory BNJD04A028-1,591 Standard 1,591 3,181 3,664 Call Factory Call Factory Call Factory BNJD04A032-1,591 Standard 1,591 3,181 4,842 Call Factory Call Factory Call Factory BNJD06A042-2,387 Standard 2,387 4,773 5,495 Call Factory Call Factory Call Factory BNJD06A048-2,387 Standard 2,387 4,773 7,844 Call Factory Call Factory Call Factory BNJD08A056-3,181 Standard 3,181 6,363 8,292 Call Factory Call Factory Call Factory BNJD08A065-3,181 Standard 3,181 6,363 11,054 Call Factory Call Factory Call Factory BNJD10A Standard 3,977 7,955 10,347 Call Factory Call Factory Call Factory BNJD10A Standard 3,977 7,955 13,798 Call Factory Call Factory Call Factory BNJD12A100-4,773 Standard 4,773 9,545 16,561 Call Factory Call Factory Call Factory BNJD14A110-5,568 Standard 5,568 11,136 19,324 Call Factory Call Factory Call Factory Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

220 Air-Cooled Condensers Microchannel Condenser Product Description The microchannel air-cooled condenser platform provides significant refrigerant and energy savings vs. standard round tube plate fin condensers. These condensers can provide more than a 70% reduction in condenser refrigerant charge due to an efficient coil design and low internal volume. This condenser is available with variable speed EC motors which continuously adjust speed to optimize system performance, providing significant energy savings and sound reduction. The all-aluminum construction of these microchannel coils virtually eliminates the risk of galvanic corrosion enabling application even in harsh environments and coastal areas. The use of microchannel coil technology and energy efficient variable speed EC motors makes this product qualified to be included in the E Solutions product portfolio. Standard Features Overview Ease of Installation & Service Up to 34% lighter than comparable air-cooled condensers with round-tube, plate fin coils Approximately 25% lower in height (with same clearance) compared to traditional air-cooled condensers. 20 Clearance legs are standard with 40 extended legs available as an option Standard connection manifold provided for single circuiting. Other circuiting configurations are available. Factory wired for customer supplied analog signal Direct acting, series wired motor control Through-the-door non-fused disconnect switch End access panels for coil-cleaning Reliable & Durable The mono-metal construction of the microchannel coils virtually eliminates the risk of galvanic corrosion. A zinc cladding standard on all coils provides additional corrosion resistance for harsh environments. Standard product warranty of 1 year with a 2 year warranty on the microchannel coil and a 3 year warranty on the variable speed EC motors. Performance 70% or more reduction in refrigerant charge due to microchannel coils very high primary to secondary surface area ratio. This allows very efficient heat exchange while maintaining a low internal tube volume. Available variable speed EC motors provide optimal energy and sound performance Fixed speed AC motors are designed to be compatible for use with variable frequency drives (VFD's). Internal baffles between all fan cells. SunSource solar energy option also available on this product. Certifications Section 3 Nomenclature Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 215

221 Air-Cooled Condensers Microchannel Condenser Need to customize? Configurable s Pricing Look below for factory-installed fan control, electrical, and mechanical options. Configurable s, Motor Voltages, & s Specify model, motor voltage, and coil circuiting configuration at time of order. Standard connection manifold is for a single circuit. Other circuiting configurations are available. Please see accompanying technical specifications. Configurable by Motor Voltage /3/60 460/3/60 <001>s with 710mm VSEC Motors Fan Config. Notes NRGD02A014 35,156 35,156 2x1 - NRGD04A027 71,731 71,731 2x2 - NRGD06A , ,596 2x3 - NRGD08A , ,008 2x4 - <001>s with 710mm AC Motors NRJD02A014 19,932 19,932 2x1 - NRJD04A027 39,814 39,814 2x2 - NRJD06A041 59,741 59,741 2x3 - NRJD08A054 79,992 79,992 2x4 - Microchannel Condenser Can t Find An Option? Options Pricing VSEC s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Section 3 Factory-Installed Fan Control, Electrical, and Mechanical Options Standard factory-installed connection manifold is for a single circuit. Other circuiting configurations are available and must be specified at time of order. Option Code Fan Control Options Option Description Adder by (US$) NRGD02A014 NRGD04A027 NRGD06A041 NRGD08A054 ECC.002 CPC Analog Control Board 3,075 3,075 3,075 3,075 ECC.003 Danfoss Analog Control Board 3,408 3,408 3,408 3,408 ECC.004 Novar Analog Control Board 3,240 3,240 3,240 3,240 ECC.005 Proportional Pressure Control 2,176 2,176 2,176 2,176 Electrical Options MP.002 Individual Motor Fuses ,429 1,905 MP.003 Individual Circuit Breakers (230V or 460V) 948 1,891 2,835 3,763 Mechanical Options LEGC.002 Extended Legs, 40" Other Options PKG.002 Export Crating 984 1,421 1,857 2, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

222 Air-Cooled Condensers Microchannel Condenser Options Pricing AC s Factory-Installed Fan Control, Electrical, and Mechanical Options Other circuiting configurations are available and must be specified at time of order. Option Code Fan Control Options Option Description Adder by (US$) NRJD02A014 NRJD04A027 NRJD06A041 NRJD08A054 FC.014 CPC Analog Control Board 2,846 2,846 2,846 2,846 FC.002 2P TB FC FC.003 Ambient Fan Cycling 1,389 1,389 1,389 1,389 FC.006 Pressure Fan Cycling Mech. 2,221 2,221 2,221 2,221 FC.007 Pressure Fan Cycling Elec. 2,507 2,507 2,507 2,507 FC.012 Danfoss Analog Control Board 3,378 3,378 3,378 3,378 FC.013 Novar Analog Control Board 3,363 3,363 3,363 3,363 Electrical Options CV.002 Control Circuit Transformer Mechanical Options LEGC.002 Extended Legs, 40" Other Options PKG.002 Export Crating 984 1,421 1,857 2,294 2P TB FC - Two Pole Terminal Board Fan Cycling Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 217

223 Fluid Coolers FN Fluid Coolers Overview Section 3 Product Description Direct drive fluid coolers with vertical air flow are designed to save time on installation, provide excellent performance, long service life and a wide range of performance selections. These units are ideal for commercial/industrial locations. Certifications Standard Features 10 fins per inch spacing standard. 8, 12, and 14 fins per inch spacing available as an option. 1/2 models feature a Floating Tube coil design and 5/8 models feature a bushing plate floating tube coil design. These coil designs virtually eliminate tube sheet leaks. Coil includes a 5 year leak warranty at tube sheets and center supports. Internal baffles provided between all fan cells Fluid Coolers from 1 to 5 fans in length are available with 1/2 diameter tubes to maximize heat transfer. Fluid Coolers from 3 to 6 fans in length are available with 5/8 diameter tubes to minimize fluid pressure drop. Wide selection of circuit options maximize performance at minimal cost Coated steel fan guards for optimal corrosion protection Weather resistant control panel with factory-mounted door interrupt disconnect switch Coils are fabricated with corrugated aluminum fins with staggered copper tubes for optimum heat transfer. All units are pressure tested prior to shipment 2 year product warranty s with Variable Speed EC Motors (VSEC) - FNE s EC motor, swept fan blade and venture incorporating integrated variable speed technology Aluminum housing for an attractive appearance and corrosion protection, with painted galvanized steel, or galvanized steel as an option Side access panels for ease of cleaning coils 3-year warranty on EC Motors s with 830 or 540 RPM Fixed Speed Motors - FNL or FNQ s Direct drive fan motors in 830 or 540 RPM Fan blade provides an unprecedented sound level of 49.6 dba ( ft.) ServiceEase motor mount feature, allows for ease of motor service and reduces likelihood of damage to the coils during servicing Coils incorporate the latest advancements in coil technology to provide maximum capacity Galvanized steel housing High efficiency, three-phase fan motors with ball bearings and internal overload protection s with 1140 RPM Fixed Speed Motors - FNH s Direct drive fan motors Patented ServiceEase motor mount New, high efficiency coil designed for optimum performance Galvanized steel housing High efficiency, three-phase fan motors with ball bearings and internal overload protection Nomenclature F N H S 01 H 3 01 Product Line Vintage Width Fans Tube Diameter Rows Coil # F = Fluid Coolers H = 1140 RPM, 1.5 HP L = 830 RPM, 1.5 HP Q = 540 RPM, 0.5 HP E = VSEC Motor S = Single D = Double # of Fans (01-12) H = 1/2 F = 5/8 # of Rows (2-4) 218 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

224 Fluid Coolers FN Fluid Coolers FNH s 1.5 HP 1140 RPM Motors Rev. 01/18 Need to customize? Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable 1/2 Diameter - Single Row s by Motor Voltage /3/60 460/3/60 575/3/60 Look on page starting 223 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 226 for condenser fin and coil protection options. Fan Config. FNHS01H301 8,008 8,008 8,239 1x1 FNHS01H402 10,236 10,236 10,467 1x1 FNHS02H203 12,775 12,775 13,237 1x2 FNHS02H304 15,461 15,461 15,922 1x2 FNHS02H405 19,386 19,386 19,847 1x2 FNHS03H306 24,114 24,114 24,807 1x3 FNHS03H407 27,358 27,358 28,051 1x3 FNHS04H308 31,224 31,224 32,147 1x4 FNHS04H409 35,750 35,750 36,674 1x4 FNHS05H310 41,033 41,033 42,188 1x5 FNHS05H411 47,382 47,382 48,537 1x5 1/2 Diameter - Double Row s FNHD04H212 25,684 25,684 26,607 2x2 FNHD04H313 31,370 31,370 32,293 2x2 FNHD04H414 36,485 36,485 37,409 2x2 FNHD06H315 47,409 47,409 48,795 2x3 FNHD06H416 56,561 56,561 57,947 2x3 FNHD08H317 64,892 64,892 66,739 2x4 FNHD08H418 76,226 76,226 78,073 2x4 FNHD10H319 81,246 81,246 83,555 2x5 FNHD10H420 94,251 94,251 96,560 2x5 5/8 Diameter - Single Row s FNHS03F301 28,170 28,170 28,863 1x3 FNHS03F402 32,766 32,766 33,459 1x3 FNHS04F303 37,109 37,109 38,033 1x4 FNHS04F404 43,528 43,528 44,452 1x4 FNHS05F305 48,308 48,308 49,462 1x5 FNHS05F406 56,966 56,966 58,120 1x5 FNHS06F307 60,179 60,179 61,564 1x6 FNHS06F408 66,968 66,968 68,353 1x6 5/8 Diameter - Double Row s FNHD06F311 55,923 55,923 57,308 2x3 FNHD06F412 67,726 67,726 69,111 2x3 FNHD08F313 76,717 76,717 78,564 2x4 FNHD08F414 91,783 91,783 93,630 2x4 FNHD10F315 95,796 95,796 98,105 2x5 FNHD10F , , ,729 2x5 FNHD12F , , ,559 2x6 FNHD12F , , ,137 2x6 s Effective January 1 st s and specifications subject to change without notice. Notes: For sizing and selection assistance, use Heatcraft's new ProSelect software or contact your local Sales Representative or Account Engineer. 219 Section 3

225 Fluid Coolers FN Fluid Coolers FNL s 1.5 HP 830 RPM Motors Section Need to customize? Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable 1/2 Diameter - Single Row s by Motor Voltage /3/60 460/3/60 575/3/60 Look on page starting 223 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 226 for condenser fin and coil protection options. Fan Config. FNLS01H321 8,289 8,289 8,520 1x1 FNLS01H422 10,593 10,593 10,824 1x1 FNLS02H223 13,223 13,223 13,684 1x2 FNLS02H324 16,001 16,001 16,463 1x2 FNLS02H425 20,064 20,064 20,525 1x2 FNLS03H326 24,958 24,958 25,651 1x3 FNLS03H427 28,316 28,316 29,009 1x3 FNLS04H328 32,317 32,317 33,240 1x4 FNLS04H429 37,001 37,001 37,925 1x4 FNLS05H330 42,469 42,469 43,624 1x5 FNLS05H431 49,041 49,041 50,196 1x5 1/2 Diameter - Double Row s FNLD04H232 26,582 26,582 27,506 2x2 FNLD04H333 32,468 32,468 33,391 2x2 FNLD04H434 37,762 37,762 38,686 2x2 FNLD06H335 49,069 49,069 50,455 2x3 FNLD06H436 58,542 58,542 59,927 2x3 FNLD08H337 67,163 67,163 69,010 2x4 FNLD08H438 78,893 78,893 80,740 2x4 FNLD10H339 84,089 84,089 86,398 2x5 FNLD10H440 97,550 97,550 99,859 2x5 5/8 Diameter - Single Row s FNLS03F321 29,156 29,156 29,849 1x3 FNLS03F422 33,913 33,913 34,606 1x3 FNLS04F323 38,408 38,408 39,332 1x4 FNLS04F424 45,052 45,052 45,975 1x4 FNLS05F325 49,999 49,999 51,153 1x5 FNLS05F426 58,960 58,960 60,114 1x5 FNLS06F327 62,285 62,285 63,670 1x6 FNLS06F428 69,312 69,312 70,697 1x6 5/8 Diameter - Double Row s FNLD06F331 57,880 57,880 61,345 2x3 FNLD06F432 70,096 70,096 71,481 2x3 FNLD08F333 79,402 79,402 81,249 2x4 FNLD08F434 94,996 94,996 96,843 2x4 FNLD10F335 99,149 99, ,458 2x5 FNLD10F , , ,699 2x5 FNLD12F , , ,891 2x6 FNLD12F , , ,945 2x6 Notes: For sizing and selection assistance, use Heatcraft's new ProSelect software or contact your local Sales Representative or Account Engineer. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

226 Fluid Coolers FN Fluid Coolers FNQ s 0.5 HP 540 RPM Motors Rev. 01/18 Need to customize? Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable 1/2 Diameter - Single Row s by Motor Voltage /3/60 460/3/60 575/3/60 Look on page starting 224 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 227 for condenser fin and coil protection options. Fan Config. FNQS01H341 8,008 8,008-1x1 FNQS01H442 10,236 10,236-1x1 FNQS02H243 12,775 12,775-1x2 FNQS02H344 15,461 15,461-1x2 FNQS02H445 19,386 19,386-1x2 FNQS03H346 24,114 24,114-1x3 FNQS03H447 27,358 27,358-1x3 FNQS04H348 31,224 31,224-1x4 FNQS04H449 35,750 35,750-1x4 FNQS05H350 41,033 41,033-1x5 FNQS05H451 47,382 47,382-1x5 1/2 Diameter - Double Row s FNQD04H252 25,684 25,684-2x2 FNQD04H353 31,370 31,370-2x2 FNQD04H454 36,485 36,485-2x2 FNQD06H355 47,409 47,409-2x3 FNQD06H456 56,561 56,561-2x3 FNQD08H357 64,892 64,892-2x4 FNQD08H458 76,226 76,226-2x4 FNQD10H359 81,246 81,246-2x5 FNQD10H460 94,251 94,251-2x5 5/8 Diameter - Single Row s FNQS03F341 28,170 28,170-1x3 FNQS03F442 32,766 32,766-1x3 FNQS04F343 37,109 37,109-1x4 FNQS04F444 43,528 43,528-1x4 FNQS05F345 48,308 48,308-1x5 FNQS05F446 56,966 56,966-1x5 FNQS06F347 60,179 60,179-1x6 FNQS06F448 66,968 66,968-1x6 5/8 Diameter - Double Row s FNQD06F351 55,923 55,923-2x3 FNQD06F452 67,726 67,726-2x3 FNQD08F353 76,717 76,717-2x4 FNQD08F454 91,783 91,783-2x4 FNQD10F355 95,796 95,796-2x5 FNQD10F , ,420-2x5 FNQD12F , ,788-2x6 FNQD12F , ,366-2x6 s Effective January 1 st s and specifications subject to change without notice. Notes: For sizing and selection assistance, use Heatcraft's new ProSelect software or contact your local Sales Representative or Account Engineer. 221 Section 3

227 Fluid Coolers FN Fluid Coolers FNE s VSEC Motors Section Need to customize? Configurable s, Motor Voltages, & s Specify model motor voltage at time of order Configurable 1/2 Diameter - Single Row s by Motor Voltage /3/60 460/3/60 575/3/60 Look on page starting 223 for factory-installed fan cycling, electrical, and mechanical options. Look on page starting 226 for condenser fin and coil protection options. Fan Config. FNES01H361 15,455 15,455-1x1 FNES01H462 19,755 19,755-1x1 FNES02H263 24,657 24,657-1x2 FNES02H364 29,839 29,839-1x2 FNES02H465 37,414 37,414-1x2 FNES03H366 46,541 46,541-1x3 FNES03H467 52,802 52,802-1x3 FNES04H368 60,262 60,262-1x4 FNES04H469 68,998 68,998-1x4 FNES05H370 79,194 79,194-1x5 FNES05H471 91,448 91,448-1x5 1/2 Diameter - Double Row s FNED04H272 49,570 49,570-2x2 FNED04H373 60,544 60,544-2x2 FNED04H474 70,416 70,416-2x2 FNED06H375 91,500 91,500-2x3 FNED06H , ,164-2x3 FNED08H , ,241-2x4 FNED08H , ,115-2x4 FNED10H , ,805-2x5 FNED10H , ,904-2x5 5/8 Diameter - Single Row s FNES03F361 54,369 54,369-1x3 FNES03F462 63,239 63,239-1x3 FNES04F363 71,621 71,621-1x4 FNES04F464 84,009 84,009-1x4 FNES05F365 93,235 93,235-1x5 FNES05F , ,945-1x5 FNES06F , ,145-1x6 FNES06F , ,248-1x6 5/8 Diameter - Double Row s FNED06F , ,931-2x3 FNED06F , ,711-2x3 FNED08F , ,063-2x4 FNED08F , ,141-2x4 FNED10F , ,887-2x5 FNED10F , ,901-2x5 FNED12F , ,911-2x6 FNED12F , ,117-2x6 Notes: For sizing and selection assistance, use Heatcraft's new ProSelect software or contact your local Sales Representative or Account Engineer. s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

228 Fluid Coolers FN Fluid Coolers Options Pricing - VSEC s Can t Find An Option? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Motors are /3/60 or 460/3/60. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Option Code Fan Cycling Options Option Description Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 2x2 2x3 2x4 2x5 2x6 FC.019 Proportional Lvg Fluid Temp Control 2,176 2,176 2,176 2,176 2,176 2,176 4,351 4,351 4,351 4,351 4,351 Electrical Options DISC.002 Fused Disconnect ,191 1, ,426 1,907 2,384 2,854 MP.002 Individual Motor Fuses ,191 1, ,429 1,905 2,382 2,858 MP.004 Paired Motor Fuses ,191 1,429 MP.003 Individual Circuit Breakers (230V or 460V) ,422 1,896 2,370 2,844 1,896 2,844 3,792 4,740 5,688 MP.005 Paired Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 MTB.001 Individual Motor Terminal Boards ,328 1,660 1,992 MTB.002 Paired Motor Terminal Boards Mechanical Options CM.003 Painted Cabinet w/ Side Access CM.004 Galvanized Cabinet w/ Side Access ,056-1,320-1,584-1,056-1,584-2,112-2,640-3,168 LEGS.002 Extended Legs, 30" LEGS.003 Extended Legs, 36" LEGS.004 Extended Legs, 42" LEGS.005 Unit Frame, Std. Legs, 20" 1,684 2,429 3,177 4,550 5,506 6,566 2,429 3,177 4,550 5,506 6,566 LEGS.006 Unit Frame, Ext. Legs, 42" 1,801 2,667 3,533 5,024 6,099 7,280 2,667 3,533 5,024 6,099 7,280 Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 223

229 Fluid Coolers FN Fluid Coolers Can t Find An Option? Options Pricing - FNH/FNL/FNQ s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Factory-Installed Fan Cycling, Electrical, and Mechanical Options Fans are cycled in pairs on double wide units. Motor circuit breakers are not available on 575V units. Motor terminal boards are not available on units with fan cycling. When ordering toggle switch option, please specify whether switches are to be internally or externally mounted. Fused disconnect option is only available on units with an MOP of 60 or less. Please see accompanying technical specifications. Fan cycling kit does not include control circuit transformer. Optional factory installed control transformers are available to convert 460V or 575V main power supplies to 230V, 115V or 24V control power or 230V main power to 115V or 24V control power. Section 3 Option Code Option Description Fan Cycling Options (Must Select Fan Cycling and Contactor Option) Adder by Fan Configuration (US$) 1x1 1x2 1x3 1x4 1x5 1x6 2x2 2x3 2x4 2x5 2x6 FCC.004 Individual Motor Contactors: 230V, 115V, or 24V ,190 1, ,428 1,904 2,380 2,856 FCC.001 Paired Motor Contactors: 230V, 115V, or 24V ,190 1,428 FC.003 Lvg. Fluid Temperature Fan Cycling (Elec.) 1,671 2,032 3,218 4,403 5,590 6,514 2,032 3,218 4,403 5,590 5,590 Electrical Options CV.002 Control Circuit Transformer: 230V, 115V, or 24V MP.002 Individual Motor Fuses ,191 1, ,429 1,905 2,382 2,858 MP.004 Paired Motor Fuses ,191 1,429 MP.003 Individual Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 1,897 2,845 3,794 4,742 5,691 MP.005 Paired Circuit Breakers (230V or 460V) ,423 1,897 2,371 2,845 MTB.001 Individual Motor Terminal Boards ,331 1,664 2,250 MTB.002 Paired Motor Terminal Boards FCS.002 Fan Toggle Switches ,186 FCS.004 Paired Fan Toggle Switches DISC.002 Fused Disconnect ,191 1, ,426 1,907 2,384 2,854 COND.002 Sealtite Wiring to Electrical Box 687 1,377 2,065 2,753 3,440 4,131 2,753 4,130 5,506 6,618 7,941 Mechanical Options CM.004 Aluminum Cabinet ,057 1,321 1,585 1,057 1,585 2,113 2,642 3,170 CM.003 Pre-Painted Steel Cabinet ,057 1,321 1,585 1,057 1,585 2,113 2,642 3,170 CM.004 Coil Access Panels, Galv ,057 1,321 1,585 1,057 1,585 2,113 2,642 3,170 CM.005 Coil Access Panels, Aluminum 530 1,060 1,590 2,120 2,650 3,180 2,120 3,180 4,240 5,300 6,360 CM.006 Coil Access Panels, Painted Steel 530 1,060 1,590 2,120 2,650 3,180 2,120 3,180 4,240 5,300 6,360 VEN.002 Hinged Venturi 563 1,125 1,688 2,251 2,813 3,376 2,251 3,376 4,501 5,626 6,752 LEGS.002 Extended Legs, 30" LEGS.003 Extended Legs, 36" LEGS.004 Extended Legs, 42" LEGS.005 Unit Frame, Std. Legs, 20" 1,684 2,429 3,177 4,550 5,506 6,566 2,429 3,177 4,550 5,506 6,566 LEGS.006 Unit Frame, Ext. Legs, 42" 1,801 2,667 3,533 5,024 6,099 7,280 2,667 3,533 5,024 6,099 7, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

230 Fluid Coolers FN Fluid Coolers Can t Find An Option? Connection Options - All s Connections Options - All s Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Option Code Threaded Connection Row of Fans Number of Feeds Connection Size Adder THD " MPT 426 THD /2" MPT 666 THD " MPT 1,331 THD " MPT 853 THD /2" MPT 1,331 THD " MPT 2,667 Flanged Connection FLG " 993 FLG /2" 1,134 FLG " 1,435 FLG " 1,986 FLG /2" 2,267 FLG " 2,870 Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 225

231 Fluid Coolers FN Fluid Coolers Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Section Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection s with 1140 RPM (1.5HP) Motors - Single Row (1/2 Diameter) Coil Protection Options Bronz-Glow Coating Copper Fin Coil FNHS01H Standard ,453 4,375 FNHS01H Standard ,222 4,486 6,249 FNHS02H Standard 795 1,591 1,243 6,423 6,249 FNHS02H Standard 795 1,589 1,490 7,285 10,510 FNHS02H Standard 795 1,589 2,420 7,590 14,204 FNHS03H306-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNHS03H407-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNHS04H308-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNHS04H409-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNHS05H310-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNHS05H411-1,986 Standard 1,986 3,973 6,897 16,964 39,204 s with 1140 RPM (1.5HP) Motors - Double Row (1/2 Diameter) FNHD04H212-1,589 Standard 1,589 3,182 2,482 12,845 13,068 FNHD04H313-1,589 Standard 1,589 3,178 3,664 14,570 22,726 FNHD04H414-1,589 Standard 1,589 3,178 4,842 15,179 31,249 FNHD06H315-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNHD06H416-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNHD08H317-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNHD08H418-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNHD10H319-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNHD10H420-3,973 Standard 3,973 7,946 13,798 33,929 81,816 s with 1140 RPM (1.5HP) Motors - Single Row (5/8 Diameter) FNHS03F301-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNHS03F402-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNHS04F303-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNHS04F404-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNHS05F305-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNHS05F406-1,986 Standard 1,986 3,973 6,897 16,964 39,204 FNHS06F307-2,384 Standard 2,384 4,767 7,245 18,281 45,027 FNHS06F408-2,384 Standard 2,384 4,767 8,280 18,701 47,726 s with 1140 RPM (1.5HP) Motors - Double Row (5/8 Diameter) FNHD06F311-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNHD06F412-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNHD08F313-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNHD08F414-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNHD10F315-3,973 Standard 3,973 7,946 10,347 32,121 63,464 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

232 Fluid Coolers FN Fluid Coolers Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection Coil Protection Options Bronz-Glow Coating Copper Fin Coil FNHD10F416-3,973 Standard 3,973 7,946 13,798 33,929 81,816 FNHD12F317-4,767 Standard 4,767 9,535 14,489 36,562 90,054 FNHD12F418-4,767 Standard 4,767 9,535 16,561 37,465 99,997 s with 830 RPM (1.5HP) Motors - Single Row (1/2 Diameter) FNLS01H Standard ,453 4,375 FNLS01H Standard ,222 4,486 6,249 FNLS02H Standard 795 1,591 1,243 6,423 6,249 FNLS02H Standard 795 1,589 1,490 7,285 10,510 FNLS02H Standard 795 1,589 2,420 7,590 14,204 FNLS03H326-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNLS03H427-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNLS04H328-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNLS04H429-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNLS05H330-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNLS05H431-1,986 Standard 1,986 3,973 6,897 16,964 39,204 s with 830 RPM (1.5HP) Motors - Double Row (1/2 Diameter) FNLD04H232-1,589 Standard 1,589 3,182 2,482 12,845 13,068 FNLD04H333-1,589 Standard 1,589 3,178 3,664 14,570 22,726 FNLD04H434-1,589 Standard 1,589 3,178 4,842 15,179 31,249 FNLD06H335-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNLD06H436-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNLD08H337-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNLD08H438-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNLD10H339-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNLD10H440-3,973 Standard 3,973 7,946 13,798 33,929 81,816 s with 830 RPM (1.5HP) Motors - Single Row (5/8 Diameter) FNLS03F321-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNLS03F422-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNLS04F323-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNLS04F424-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNLS05F325-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNLS05F426-1,986 Standard 1,986 3,973 6,897 16,964 39,204 FNLS06F327-2,384 Standard 2,384 4,767 7,245 18,281 45,027 FNLS06F428-2,384 Standard 2,384 4,767 8,280 18,701 47,726 Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 227

233 Fluid Coolers FN Fluid Coolers Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Section 3 Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection s with 830 RPM (1.5HP) Motors - Double Row (5/8 Diameter) Coil Protection Options Bronz-Glow Coating Copper Fin Coil FNLD06F331-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNLD06F432-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNLD08F333-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNLD08F434-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNLD10F335-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNLD10F436-3,973 Standard 3,973 7,946 13,798 33,929 81,816 FNLD12F337-4,767 Standard 4,767 9,535 14,489 36,562 90,054 FNLD12F438-4,767 Standard 4,767 9,535 16,561 37,465 99,997 s with 540 RPM (0.5HP) Motors - Single Row (1/2 Diameter) FNQS01H Standard ,453 4,375 FNQS01H Standard ,222 4,486 6,249 FNQS02H Standard 795 1,591 1,243 6,423 6,249 FNQS02H Standard 795 1,589 1,490 7,285 10,510 FNQS02H Standard 795 1,589 2,420 7,590 14,204 FNQS03H346-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNQS03H447-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNQS04H348-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNQS04H449-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNQS05H350-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNQS05H451-1,986 Standard 1,986 3,973 6,897 16,964 39,204 s with 540 RPM (0.5HP) Motors - Double Row (1/2 Diameter) FNQD04H252-1,589 Standard 1,589 3,182 2,482 12,845 13,068 FNQD04H353-1,589 Standard 1,589 3,178 3,664 14,570 22,726 FNQD04H454-1,589 Standard 1,589 3,178 4,842 15,179 31,249 FNQD06H355-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNQD06H456-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNQD08H357-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNQD08H458-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNQD10H359-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNQD10H460-3,973 Standard 3,973 7,946 13,798 33,929 81,816 s with 540 RPM (0.5HP) Motors - Single Row (5/8 Diameter) FNQS03F341-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNQS03F442-1,192 Standard 1,192 2,384 3,923 10,781 23, s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

234 Fluid Coolers FN Fluid Coolers Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Rev. 01/18 Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI Adders Guard Fin Protection Coil Protection Options Bronz-Glow Coating Copper Fin Coil FNQS04F343-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNQS04F444-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNQS05F345-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNQS05F446-1,986 Standard 1,986 3,973 6,897 16,964 39,204 FNQS06F347-2,384 Standard 2,384 4,767 7,245 18,281 45,027 FNQS06F448-2,384 Standard 2,384 4,767 8,280 18,701 47,726 s with 540 RPM (0.5HP) Motors - Double Row (5/8 Diameter) FNQD06F351-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNQD06F452-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNQD08F353-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNQD08F454-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNQD10F355-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNQD10F456-3,973 Standard 3,973 7,946 13,798 33,929 81,816 FNQD12F357-4,767 Standard 4,767 9,535 14,489 36,562 90,054 FNQD12F458-4,767 Standard 4,767 9,535 16,561 37,465 99,997 s with VSEC Motors - Single Row (1/2 Diameter) FNES01H Standard ,453 4,375 FNES01H Standard ,222 4,486 6,249 FNES02H Standard 795 1,591 1,243 6,423 6,249 FNES02H Standard 795 1,589 1,490 7,285 10,510 FNES02H Standard 795 1,589 2,420 7,590 14,204 FNES03H366-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNES03H467-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNES04H368-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNES04H469-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNES05H370-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNES05H471-1,986 Standard 1,986 3,973 6,897 16,964 39,204 s with VSEC Motors - Double Row (1/2 Diameter) FNED04H272-1,589 Standard 1,589 3,182 2,482 12,845 13,068 FNED04H373-1,589 Standard 1,589 3,178 3,664 14,570 22,726 FNED04H474-1,589 Standard 1,589 3,178 4,842 15,179 31,249 FNED06H375-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNED06H476-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNED08H377-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNED08H478-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNED10H379-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNED10H480-3,973 Standard 3,973 7,946 13,798 33,929 81,816 s Effective January 1 st s and specifications subject to change without notice. 229 Section 3

235 Fluid Coolers FN Fluid Coolers Coil Options Pricing - All s Can t Find An Option? Condenser Fin and Coil Protection Options Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Standard Fins Per Inch is FPI reduces the capacity of a model and 12 FPI and 14 FPI increase the capacity of a model. Configurable Fins Per Inch (FPI) Options 8 FPI 10 FPI 12 FPI 14 FPI s with VSEC Motors - Single Row (5/8 Diameter) Adders Guard Fin Protection Coil Protection Options Bronz-Glow Coating Copper Fin Coil FNES03F361-1,192 Standard 1,192 2,384 2,748 10,117 17,045 FNES03F462-1,192 Standard 1,192 2,384 3,923 10,781 23,863 FNES04F363-1,589 Standard 1,589 3,178 4,145 13,500 25,000 FNES04F464-1,589 Standard 1,589 3,178 5,528 13,919 29,544 FNES05F365-1,986 Standard 1,986 3,973 5,174 16,061 30,681 FNES05F466-1,986 Standard 1,986 3,973 6,897 16,964 39,204 FNES06F367-2,384 Standard 2,384 4,767 7,245 18,281 45,027 FNES06F468-2,384 Standard 2,384 4,767 8,280 18,701 47,726 s with VSEC Motors - Double Row (5/8 Diameter) FNED06F371-2,384 Standard 2,384 4,767 5,495 20,233 36,363 FNED06F472-2,384 Standard 2,384 4,767 7,844 21,560 50,608 FNED08F373-3,178 Standard 3,178 6,356 8,292 27,002 51,135 FNED08F474-3,178 Standard 3,178 6,356 11,054 27,838 61,078 FNED10F375-3,973 Standard 3,973 7,946 10,347 32,121 63,464 FNED10F476-3,973 Standard 3,973 7,946 13,798 33,929 81,816 FNED12F377-4,767 Standard 4,767 9,535 14,489 36,562 90,054 FNED12F478-4,767 Standard 4,767 9,535 16,561 37,465 99,997 Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

236 Fluid Coolers FN Fluid Coolers Can t Find An Option or Accessory? Shipped-Loose Accessories Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Connection Manifold Kits Fluid cooler manifolds are for converting standard two circuit fluid coolers to single circuit. includes all tube fittings for field brazing to inlet and outlet Feeds Part Number Inlet Outlet Qty Size Qty Size 18 MANF18 1, / /8 28 MANF28 1, / /8 36 MANF36 1, / /8 42 MANF42 2, / /8 56 MANF56 2, / /8 84 MANF84 3, / /8 112 MANF112 3, / /8 Section 3 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 231

237 Fluid Coolers Small Fluid Coolers Product Description Direct-drive fluid coolers, available in horizontal or vertical airflow, are ideal for commercial/industrial locations. Available in sizes 5 to 26 tons, these units are easy to install and maintain. Specifically engineered for outdoor installations, the cabinet is constructed of heavy gauge aluminum to resist corrosion in all climates. Certifications Standard Features Overview Ease of Installation & Service Completely assembled and tested at the factory All fan motor leads are wired to a weatherproof electrical enclosure for singlepoint field wiring Reliable & Durable Cabinets are heavy-duty construction and designed for outdoor applications; tube sheets and all structural members are fabricated from galvanized steel Cabinet panels are fabricated from heavy-gauge aluminum for an attractive appearance and corrosion protection Coils are fabricated with corrugated aluminum fins with staggered copper tubes for optimum heat transfer; all units are pressure-tested, dehydrated and pressurized prior to shipment Balanced fans, featuring heavy gauge aluminium blades riveted to plated steel spiders Corrosion resistant fan blades and guards Fan guards are coated steel for optimum corrosion protection Wide fin spacing minimizes fouling from foreign materials Fan motors have thermal overload protection and permanently lubricated ball bearings Performance Fully baffled fan sections provide structural strength and prevent fan wind-milling in the off cycle Coils are the patented cross-fin coil with staggered seamless copper tubes expanded into full collar aluminum fins for high heat transfer efficiency Versatile Available in horizontal or vertical airflow Sizes available from 10 GPM through 160 GPM A wide selection of circuit options maximizes performance at minimal cost Section 3 Nomenclature 232 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

238 Fluid Coolers Small Fluid Coolers Configurable s & Options Pricing Configurable s, Factory-Installed Options, & s Specify model motor voltage and type at time of order /1/60 motors may be field connected to 230/3/60 power. Standard Control Circuit Voltage is 230V unless otherwise specified. 24V & 115V are available at no additional cost. Specify control circuit voltage when ordering. Fan cycling pricing does not include control circuit transformer for 460V or 575V units. If needed, transformer can be ordered from ship-loose accessories. Factory-Installed Options Adders Fan Fan Cycling Options Coil Coatings Configurable Config. Guard Coated 1 PH Amb. 3 PH Amb. ElectroFin Coil Bronz-Glow Coating Fins /1/60 with PSC Motors DFT005 5,778 1x Call Factory Call Factory DFT008 7,298 1x Call Factory Call Factory DFT010 8,920 1x Call Factory Call Factory DFT012 10,016 1x Call Factory Call Factory DFT014 11,456 1x Call Factory Call Factory DFT016 12,556 1x Call Factory Call Factory DFT021 14,477 1x ,106 Call Factory Call Factory DFT023 14,886 1x ,260 Call Factory Call Factory DFT026 16,253 1x ,533 Call Factory Call Factory /3/60 with Polyphase Motors DFT005 6,120 1x Call Factory Call Factory DFT008 7,564 1x Call Factory Call Factory DFT010 9,570 1x2-1, Call Factory Call Factory DFT012 10,554 1x2-1, Call Factory Call Factory DFT014 11,992 1x2-1, Call Factory Call Factory DFT016 13,094 1x2-1, Call Factory Call Factory DFT021 15,288 1x3-1,627 1,106 Call Factory Call Factory DFT023 15,694 1x3-1,627 1,260 Call Factory Call Factory DFT026 17,060 1x3-1,627 1,533 Call Factory Call Factory 460/3/60 with Polyphase Motors DFT005 6,120 1x Call Factory Call Factory DFT008 7,564 1x Call Factory Call Factory DFT010 9,570 1x2-1, Call Factory Call Factory DFT012 10,554 1x2-1, Call Factory Call Factory DFT014 11,992 1x2-1, Call Factory Call Factory DFT016 13,094 1x2-1, Call Factory Call Factory DFT021 15,288 1x3-1,627 1,106 Call Factory Call Factory DFT023 15,694 1x3-1,627 1,260 Call Factory Call Factory DFT026 17,060 1x3-1,627 1,533 Call Factory Call Factory 575/3/60 with Polyphase Motors DFT005 6,519 1x Call Factory Call Factory DFT008 7,962 1x Call Factory Call Factory DFT010 10,366 1x2-1, Call Factory Call Factory DFT012 11,350 1x2-1, Call Factory Call Factory DFT014 12,787 1x2-1, Call Factory Call Factory DFT016 13,888 1x2-1, Call Factory Call Factory DFT021 16,482 1x3-1,627 1,106 Call Factory Call Factory DFT023 16,886 1x3-1,627 1,260 Call Factory Call Factory DFT026 18,253 1x3-1,627 1,533 Call Factory Call Factory Section 3 Rev. 01/18 Notes: 1. For selection or sizing assistance, use Heatcraft s New ProSelect software or contact your local your Sales Representative or Account Engineer. 2. Copper Fin Coils are available. Contact your Sales Representative or Account Engineer for more information. s Effective January 1 st s and specifications subject to change without notice. 233

239 Fluid Coolers Small Fluid Coolers Can t Find An Option or Accessory? Shipped-Loose Accessories Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. Part Number Description s Used On Notes Expansion tank and mounting kit ALL x24 horizontal tank, 12 gallon, 30 PSIG, non-asme R Control Circuit Transformer ALL Section s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

240 Refrigeration Controls and Technology Beacon II Refrigeration System System Overview Product Description Beacon II Refrigeration System is a patented, preassembled, factory-installed refrigeration control system featuring an integrated microcomputer-based electronic control board and an electric expansion valve at the heart of the system. With components factory mounted at both the condensing unit and evaporator, the Beacon II system can be used with single or multiple evaporator applications. While perfect for restaurants and convenience stores, the Beacon II system can be scaled up to meet the needs of larger refrigerated warehouses with optional system devices such as the Beacon II Smart Controller. Certifications Features and Benefits Reduced Installation Time/Cost Factory mounted components, testing, and programming substantially reduces field assembly and fine tuning at the job site Increased System Efficiency & Reliability Beacon II electronic control board and electric expansion valve more accurately controls the flow of refrigerant verses traditional thermal expansion and solenoid valves Preset factory superheat allowing the system to run more efficiently and reducing future adjustments Reduced Energy & Operating Costs Reduce up to 75% of unnecessary defrosts per day verses traditional timer systems with the Beacon II Smart Defrost Improved Product Integrity & Reduced Spoilage Precise temperature control improves product integrity while alarm notifications helps prevent small problems from turning into large problems Strengthen Food Safety Compliance Programs Data-logging capability helps comply with FDA and USDA HACCP food safety requirements Compatible with the Remote Refrigeration Control Web based remote monitoring and control service offering that provides instant access 24/7 to real time refrigeration system status and information Factory Mounted Components Condensing Unit Wired for Beacon II control with all necessary relays, contactors, time delay, and terminal blocks Outdoor air temperature sensor Evaporator Beacon II control board with easy to read alphanumeric LED display Three temperature sensors (defrost temp, suction temp, room temp) Electronic expansion valve that closes automatically on loss of power 24-volt transformer, 24-volt compressor contactor, low pressure time delay switch, and suction pressure transducer Eliminated Components These traditional components are not required with a Beacon II system: Liquid-line solenoid valve Room thermostat Thermal expansion valve Defrost time clock Defrost termination/fan delay switch Defrost and fan contactors Optional Devices Beacon II Smart Controller Beacon II Smart Defrost Section 4 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 235

241 Refrigeration Controls and Technology Beacon II Refrigeration System Selection & Pricing STEP 1 : Determine the condensing unit and evaporator(s) needed for the heat load and application. STEP 2 : the Beacon II condensing unit model with options from the appropriate section in this product catalog. Note : Defrost kits are not required since the Beacon II factory-installed components in the condensing unit include all the accessories necessary for defrost. STEP 3 : the evaporator(s) with the factory-installed Beacon II system option from the appropriate section in this product catalog. STEP 4 : Save more energy and further reduce operating costs by adding additional Beacon II system components from below. Beacon II Smart Controller Optional system monitoring and programming control device. Mount in a convenient location for easy access on site. Remote access capability via a web connection. Can program and control up to four condensing units with up to four evaporators on each system. Beacon II Smart Controller Part Number ,484 Beacon II Smart Defrost A patented algorithm included in the Beacon II Smart Controller. Predicts frost accumulation and initiate defrosts only when needed. Reduce up to 75% of unnecessary defrosts per day verses traditional timer systems. Section 4 Beacon II must be ordered as a system! When ordering a Beacon II system, please advise the box temperature, liquid temperature and refrigerant so that the proper evaporator nozzle can be installed. When applying an electric defrost coil in a medium temperature application, nozzle size is critical and must be evaluated. For assistance, please contact your local Sales Representative or Account Engineer. 236 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

242 Refrigeration Controls and Technology HyperCore Micro-Channel Coils General Information Product Description HyperCore microchannel condenser coils, a standard feature on the ½ - 6 HP air-cooled condensing units, are all-aluminum coils with multiple flat tubes containing small channels (microchannels) through which refrigerant flows. Heat transfer is maximized by the insertion of angled and louvered fins inbetween the flat tubes. These components are joined with two refrigerant manifolds using an aluminum-zinc alloy brazing material in a nitrogen-charged braze furnace to make the completed microchannel coil. Features & Benefits Improved Heat Transfer Performance 20-30% higher than traditional copper-aluminum round-tube plate fin (RTPF) coils with epoxy coating of the same size, enabling comparable capacity achievement with a smaller coil Improved Corrosion Protection Monometal (aluminum) construction gives no opportunity for galvanic corrosion HyperCore microchannel coils have been proven to last up to two times (2X) longer than standard RTPF coils in extended tests Reduced Refrigerant Charge & Reduced Costs Condenser coil refrigerant charge may be reduced by up to 75%, leading to as much as a 40% reduction in system charge and reducing costs for end users Improved Durability & Reduced Potential for Leaks Require only one manual braze operation versus manually brazed joints for RTPF, significantly reducing the likelihood for leaks Flat tubes serve as a fin guard to help protect the fins from damage Environmentally Friendly 100% recyclable Reduced refrigerant helps decrease the potential for ozone depletion and global warming Remote Refrigeration Control General Information Product Description The Remote Refrigeration Control, perfect for both foodservice and cold storage applications, is a web based remote monitoring and control service offering that provides instant access 24/7 to real time refrigeration system status and information. Heatcraft is proud to offer the most advanced commercial refrigeration system monitoring package available in the industry. The Remote Refrigeration Control is compatible with both the Beacon II Refrigeration System and the Mohave Advanced Hot Gas Defrost System. Features and Benefits Securely Manage Your Beacon II Refrigeration Systems From Any Web Enabled Device 24/7 Monitor and control the Beacon II refrigeration system(s) at one or more sites through a single website Secure login with multiple user level profiles and access rights Improve System Efficiency & Reliability Real-time system information and advanced reporting/graphing capabilities provide you the tools necessary to keep your system running at peak performance Increase Product Integrity & Service Call Effectiveness System Alarm Alerts sent 24/7 via or SMS text message notify you promptly of refrigeration system alarm conditions Remote troubleshooting capability improves first call resolution by providing refrigeration system data to the user Strengthen Food Safety Compliance Programs Data-logging, advanced reporting capabilities, and alarm notification capabilities help comply with FDA and USDA HACCP food safety requirements A Service Package That Meets Your Needs Collect and display 40+ datapoints from your Beacon II refrigeration system in real-time For more information, please contact your local Sales Representative or Account Engineer. Section 4 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 237

243 Refrigeration Controls and Technology Lead Lag Temperature Controller General Information Features and Benefits Controls from 2 to 4 systems Integrated thermostat with multiple temperature sensor capability Controls both conventional and Mohave refrigeration systems Suitable for either 100% redundant or split load applications Alarm capability for High and Low Temperature, Controller Power Loss and Temperature Sensor Failure Predictive control algorithm utilizing Output Time or FIFO control strategies to equalize system run times Compressor run and staging timers User friendly interface Increased system reliability Energy efficient Product Description: The Lead Lag Temperature Controller provides an integrated thermostat and staging control for cold rooms with multiple refrigeration systems. Lead Lag Temperature Controller are available for 2 to 4 systems and utilize predictive control algorithms to increase systems reliability and energy efficiency. The Lead Lag Temperature Controller is compatible with both conventional refrigeration systems and Mohave Advanced Hot Gas Defrost Systems. Cat # Number of Controlled Systems LLT42 2 4,886 LLT43 3 5,047 LLT44 4 5,208 Note: LLT units include one temperature sensor. Any additional sensors must be ordered as a separate item. Cat # Temperature Sensors Split System Controller General Information Features and Benefits Replaces three mechanical components: Defrost termination switch Defrost timer Mounted thermostat Preprogrammed parameters suited to your environment One controller for all operating temperatures Wiring eliminated to condensing unit, reducing install time Easy to read LED display 66% reduction in required defrost components Built-in alarm and error code options Section 4 Product Description: Heatcraft Worldwide Refrigeration introduces an innovative walk-in cooler controller solution to provide improved defrost control. The new Split System Controller combines three mechanical components into one electronic solution to reduce defrost complexity; providing restaurant and business operators with a simple, reliable and flexible solution. Cat # Description V & V Air Defrost V Electric Defrost 1, Field Kit- 115V Air Defrost 1, Field Kit V Air Defrost 1, Field Kit V Electric Defrost 1,565 Split System Controller is currently only offered for Low Profile unit coolers. For more information, please contact your local Sales Representative or Account Engineer. 238 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

244 Other Products and Services Air-Cooled Package Chillers Overview Standard Features Heated and insulated stainless steel braze plate evaporator. Floating Tube condenser coil design. Refrigerant carrying copper tubes do not contact any metal support sheets. Expanded anchor tubes support the coil and do not carry refrigerant. This coil design eliminates on of the major causes of leaks in chiller systems. Coil includes a 5 year leak warranty at tube sheets and center supports. Thermally protected condenser fan motors with permanently lubricated ball bearings Adjustable two valve head pressure control system with drain line check valve per circuit Liquid receiver with inlet and outlet service valves and pressure relief valve per circuit Suction accumulator per circuit Liquid line filter drier, moisture indicator/sight glass, solenoid valve and thermal expansion valve per circuit. Hot gas bypass capacity control system per circuit ETL listed control panel with microprocessor controller, 24V control transformer, compressor and condenser fan contactors and phase loss monitor s with Scroll Compressors (ACCZ s) Scroll compressor with suction and discharge valves, and crankcase heater per circuit. s with Reciprocating Compressors (ACCR s) Spring mounted semi-hermetic reciprocating compressor with suction and discharge service valves, suction and discharge vibration eliminators, and crankcase heater per circuit Product Description The ACC air-cooled process chiller product family is an important addition to the Heatcraft line of process cooling equipment. ACC chillers are designed to provide an efficient and reliable solution for a variety of process cooling applications. Units feature compact, high efficiency braze plate evaporators for improved heat transfer, advanced microprocessor controllers for optimized operation, and floating tube condenser coils for enhanced refrigerant leak protection. ACC air-cooled process chillers provide owners with dependable cooling for critical applications. Typical Applications Include: Machining (Cutting, Welding) Printing Plastic Molding Brewing Concrete Mixing Additional Industrial Processes For more information, please contact your local Sales Representative or Account Engineer. Section 4 Rev. 01/18 Nomenclature ACC Z 000 C 6 S - Compressor Type Nominal Capacity Voltage Refrigerant Air-Cooled Chiller Z = Scroll R = Reciprocating = XXX tons C = /3/60 D = 460/3/60 E = 575/3/60 6 = R-404A 7 = R-407C Number of Compressors S = Single D = Dual s Effective January 1 st s and specifications subject to change without notice. Pump/Tank Options Blank = Chiller Only P = Pump Only T = Pump/Integral Tank 239

245 Other Products and Services Screw Compressor Condensing Units Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved lubrication performance Factory-equipped microprocessor control system guarantees safe, reliable system performance Floating tube condenser coil design minimizes potential for refrigerant leaks Product Description The screw compressor condensing unit is an important addition to the Heatcraft air-cooled condensing unit product family, featuring innovative compact screw compressors and advanced microprocessor controls. The unit is designed to provide increased system reliability, reduced installation and operation costs, as well as, improved product integrity in commercial and industrial refrigeration applications. Reduced Costs of Ownership More capacity per compressor reduces number of compressors on large projects Reduced installation time and cost savings Built-in features include soft starting, slide valve unloading and digital controls for minimized operating costs Improved Product Integrity Advanced digital controls and variable capacity capability maintain more precise temperature control Minimal temperature fluctuations result in maximum product integrity Advanced diagnostic, monitoring and data logging options allow for quick system recovery For more information, please contact your local Sales Representative or Account Engineer. Section 4 Nomenclature S S V 000B M 6 D Number of Circuits Compressor Airflow Equiv. HP Temperature Range Refrigerant Voltage S = Single D = Dual S = Screw V = Vertical 050B = B = B = B = B = B = B = B = B = 140 M = Medium H = High 6 = R-404A/507 7 = R-407 D = 460/3/60 E = 575/3/ s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

246 Other Products and Services Heatcraft Commercial Financing Overview Financial Solutions Made Easy What if you could bundle everything you need, including new energy efficient commercial refrigeration equipment, control systems, installation services, maintenance programs and extended warranties, into a convenient and affordable monthly payment in less than 24 hours? Heatcraft Commercial Financing provides greater financial convenience with custom-fit financing solutions to perfectly meet your company s purchasing needs. When you finance through Heatcraft Commercial Financing, you also get these additional benefits: Easy, streamlined application process Fast approval process, with most decisions made within 2-6 business hours Financing for your entire commercial refrigeration purchase, from equipment and installation to monitoring and maintenance programs Deferred and structured payments to assist with financial planning and budgeting Tax incentives and rebates that you may qualify for when you finance/lease your purchase Contact Heatcraft Commercial Financing today to learn more about financing options that work best for your short-term needs and long-term plans. Section 4 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 241

247 Other Products and Services Mohave Advanced Hot Gas Defrost System 6 to 40 HP Split Systems Section 4 Product Description Mohave Advanced Hot Gas Defrost System is a heat pump based design consisting of a vertical discharge condensing unit matched to one or two evaporators, medium profile or large unit coolers. Featuring a stateofthe-art electronic defrost controller, the system operates in all outdoor ambient temperatures (tested to -20 F) and uses a proprietary control scheme to automatically adjust to changing conditions so that the system continues to operate at its most optimal level. The Mohave Advanced Hot Defrost System is designed for simplicity and optimal performance for use in agricultural, process cooling, cold storage and warehouse applications. The energy efficiency of this line makes it qualified to be included in the E Solutions product portfolio. Certifications Features & Benefits Most Advanced The most sophisticated controller used for hot gas defrost applications Optimizes performance with changing conditions. There is no need to seasonally adjust settings! Sensors gather information ad assess the condition of the system to defrost more efficiently Most Versatile Performs exceptionally in all ambient conditions because the controller automatically adjusts to operate efficiently and effectively. Traditional systems often have to be adjusted by hand twice a year. Service switch, which allows the system to sleep until needed next, is perfect for seasonal agricultural applications. Simplest to Use Control board is preset with factory settings optimized for model size and refrigerant type. No programming is required! Basic and expert menu modes allow for flexibility for various degrees of expertise Lowest Maintenance No valves or times to adjust for seasonal conditions No water tank to maintain or check for leaks Advanced troubleshooting keeps you in the know all the time, with a minimal amount of effort. Special Evacuation Mode opens all necessary valves Best Investment Protection Controller is customized to operate within the specified operation envelope, ensuring the safest and most efficient performance No guesswork is involved in the system settings, so you do not have to compromise the integrity of your product Detailed error and alarm codes greatly reduce troubleshooting time Compatible With Heatcraft Remote Refrigeration Control Web based remote monitoring and control service offering that provides instant access 24/7 to real time refrigeration system status and information System Components Electronic Control Board Controller completely manages timing and sequence of defrost Automatically compensates for changes in outdoor temperatures Monitors all pressures, temperatures, and set points in real time Easily programmable through a menu driven interface Conformal coated to handle the toughest conditions LED indication on the board clearly shows system status Remote alarm notification Vertical Discharge Condensing Unit Available s: 6-30 HP low temperature and 7-40 HP medium temperature Featuring Discuss semi-hermetic compressors Evaporators One or two medium profile evaporators or large unit coolers per system For more information, please contact your local Sales Representative or Account Engineer. 242 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

248 Other Products and Services Two Stage Condensing Units & Systems 5 to 30 HP Product Description Two stage condensing, units with Bitzer compressors, matched with 1 or 2 Medium Profile evaporators are designed for applications requiring a suction temperature below -40 F SST. The two stage system can operate down to -65 F SST which allows for room temperatures down to -50 F. These systems are ideal for blood, plasma, pharmaceutical, food and various other storage needs. Certifications ETL-508a listed control panel Standard Features Condensing Unit Bitzer two stage compressor Discharge and suction vibration eliminators Discharge muffler Encapsulated high pressure switch Adjustable low pressure switch with superhose Crankcase heater and crankcase pressure regulator Compressor contactor w/circuit breaker Floating Tube coil design Flooded head pressure controls Pressure fan cycling (multiple fan units) Oil separator - return line solenoid valve and time delay Mechanical subcooler Replaceable core liquid line filter drier Suction accumulator and replaceable core suction filter Defrost timer Defrost heater and evaporator fan contactors with fusing Phase monitor, anti short cycle timer, and pumpdown switch Evaporator Thermo-Flex coil design Thermostatic expansion valve factory installed Liquid line solenoid valve factory installed Low temperature motors Double wall insulated drain pan Adjustable defrost termination and fan delay For more information, please contact your local Sales Representative or Account Engineer. Section 4 Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 243

249 Other Products and Services FlexPack 5 to 18 HP Product Description FlexPack multiple compressor condensing units offer the flexibility for a wide range of applications. The modular design accommodates up to three compressors (1/2 to 6 HP Hermetic or Scroll), is available in 230/1/60 or 230/3/60, and with R-407A/C/F, R-448A/R-449A and R-404A models for medium or low temperature applications. Perfect for restaurants and convenience stores where remote condenser circuits are needed for ice machines, drink dispensers, display cases and more, this product significantly reduces air conditioning energy costs by reducing the heat load in the space. Features of this line provide outstanding results for the refrigeration system and bottom line. Certifications Features and Benefits Flexible Design Modular design accommodates up to 3 compressors (1/2 to 6 HP Hermetic or Scroll) System capacity range from 5 to 18 HP (dependent upon cabinet size) Small footprint Rooftop AC style appearance to blend with existing equipment Reduced Installation Costs and Easy Serviceability Hinged access panels to refrigeration and electrical components Single roof penetration Single-point main power Clean and intuitive electrical and piping layout Durable & Reliable 14-gauge galvanized steel frame Industrial grade, painted galvanized steel 1-year parts warranty 4-year optional compressor warranty Increased Energy Efficiency & Reduced Sound Remote condenser circuits reduce heat load into space resulting in lower air conditioning energy costs Recessed, vertical-discharge, flush-mounted 18" fans with 1100 RPM motors reduce noise levels Components Fixed high pressure switch Fixed low pressure switch on medium and high temperature compressor modules Adjustable low pressure switch on low temperatures modules Suction service ports on all modules Suction accumulator (CS & CF extended temperature compressors) Vertical receiver in 6" x 12" or 6" x 27" sizes Sealed type liquid line drier and suction filter Head pressure control valve Aluminum fin coils Crank case heater Sight glass Options Beacon II Refrigeration System available Defrost timer (air or electric) Individual compressor circuit breakers or fuses Unit fused disconnect Copper finned coils Polyester coated fins Liquid line solenoid valve Adjustable low pressure switch on high and medium temperature compressors Section 4 For more information, please contact your local Sales Representative or Account Engineer. 244 s Effective January 1 st s and specifications subject to change without notice. Rev. 01/18

250 Other Products and Services Air Handlers 03 to 75 Tons Product Description Air Handler units are available in sizes 03 through 75 tons in multiple cabinet styles. This equipment is engineered and built to fit your unique project requirements. Whether it is cooling, heating, or ventilation, multiple coil types and accessories are available to meet specific application needs. Standard Features Basic Cabinet Fan section and a coil section with double wall drain pan. Galvanized steel with 1" - 3/4 pound density mat faced fiberglass insulation. All fan sections have hinged and latched access doors. Fan Section Motors mount inside of cabinet. All units have a single fan design (either forward curved or airfoil) Single, double width, double inlet fan wheels for quiet performance and low energy consumption Fans are statically and dynamically balanced in fan section before the unit leaves the factory Fan bearings are ball bearing type selected for 200,000 hour average life. Coil Section A wide variety of coil types to meet the load requirements of conditioned spaces including water, direct expansion, heat reclaim and steam coils. Accessories Electric Heaters and remote control panels A wide variety of filter sections: flat, high capacity, and high efficiency Economizer sections Internal or external face and bypass damper section Certifications For more information, please contact your local Sales Representative or Account Engineer. Refrigeration Racks Up to 320 HP Product Description Providing a high level of design flexibility, racks are offered for indoor and outdoor applications with up to 8 parallel-piped compressors. This equipment is commonly used in cold storage applications. It is engineered and built to fit your unique project requirements and can be used with air-cooled, water-cooled or evaporative-cooled condensers. Standard Features Cabinet Larger capacity in a compact footprint 3-8 compressors on one frame Compressor Optimum compressor sizing to meet project requirements Compressor combination up to 320 HP Performance & Service Single point wiring and piping Designed for optimum energy savings, faster installation and reduced maintenance costs Controls up to 3 suction groups Total project capacity requirements in one unit Microprocessor control Defrost function flexibility Applications Food processing plants Blast cooling and freezing applications Food and beverage distribution facilities Hydrocoolers for produce cooling Section 4 Certifications ETL-508a listed control panel For more information, please contact your local Sales Representative or Account Engineer. Rev. 01/18 s Effective January 1 st s and specifications subject to change without notice. 245

Price List. BN-PL Oct. 2017

Price List. BN-PL Oct. 2017 Price BN-PL Oct. 2017 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page

More information

LK-PL Jan Price List

LK-PL Jan Price List LK-PL Jan. 2018 Price List Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler

More information

Price List. CC-PC-PL Jan. 2019

Price List. CC-PC-PL Jan. 2019 Price List CC-PC-PL Jan. 2019 Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 Low Profile Unit Cooler See page 18 11 14

More information

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3

More information

Low Profile Unit Coolers

Low Profile Unit Coolers BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

Center Mount Unit Coolers

Center Mount Unit Coolers CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4

More information

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018 ` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with

More information

Low Profile Unit Coolers

Low Profile Unit Coolers CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits

More information

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 ` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed

More information

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES ` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on

More information

Evaporator Coils. Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils. High Performance Mullion Coils

Evaporator Coils. Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils. High Performance Mullion Coils Evaporator Coils Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils High Performance Mullion Coils The AMCO High Performance Coils AMCO high performance direct expansion evaporator coils are designed

More information

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May, CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2

More information

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost. LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of

More information

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5 ` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single

More information

Slim Contour Unit Cooler

Slim Contour Unit Cooler Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost

More information

Super-Flo Low Profile Unit Cooler

Super-Flo Low Profile Unit Cooler Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for

More information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR CONDITIONS OF SALE AND WARRANTY BULLETIN KLP 4-2018 R1 Supersedes All KRAMER Price Lists Published Prior To April 2018 April, 2018 LIST PRICES Add appropriate expansion valve price(s) from page 13 of this price sheet when unit coolers

More information

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit

More information

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR CONDITIONS OF SALE AND WARRANTY BULLETIN KLP 7-2018A Supersedes All KRAMER Price Lists Published Prior To July 2018 July, 2018 LIST PRICES Prices effective 7/2/18 Add appropriate expansion valve price(s) from page 13 of this price sheet

More information

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL

More information

Low Flow Unit Coolers

Low Flow Unit Coolers BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

commercial refrigeration products

commercial refrigeration products commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile

More information

KTL Two-Way Low Profile Evaporators

KTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low

More information

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions. MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions. H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions. H and GH/G SERIES UNIT COOERS H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height,

More information

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost. bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features

More information

Industrial Unit Coolers

Industrial Unit Coolers HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and

More information

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000

More information

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions. KR Series COMPACT UNIT COOERS Technical Bulletin: KRUC_00_07 Products that provide lasting solutions. Provides Excellent Design Innovations That Enhance Overall Refrigeration Performance The KR Compact

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal

More information

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions. SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse

More information

Condensing Units w/ Screw Compressors

Condensing Units w/ Screw Compressors w/ Compressors Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved

More information

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00 BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from

More information

SMALL AIR COOLED CONDENSERS

SMALL AIR COOLED CONDENSERS Catalog KM-KDX-0816A Supersedes Catalog KM-KDS-1014A UNICON SMALL AIR COOLED CONDENSERS 2 Unicon Efficient and Reliable Kramer s Remote Air Cooled Condensers innovative design provides a wide array of

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

KTL Two-Way Low Profile Unit Coolers

KTL Two-Way Low Profile Unit Coolers PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical

More information

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now

More information

BTL Two-Way Low Profile Evaporators

BTL Two-Way Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature

More information

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products PRUCT CATALOG Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products peerlessofamerica.com Welcome to Peerless of America II Peerless of America II Inc. was founded in 1912

More information

T H I N K I N S I D E T H E B o x

T H I N K I N S I D E T H E B o x T H I N K I N S I D E T H E B o x HyperCoreTM microchannel coil technology The name behind the brands you trust. 2175 West Park Place Blvd. Stone Mountain, GA 30087 www.heatcraftrpd.com P 800.537.7775

More information

Preparation Table Raised Condiment Rail models 8000N

Preparation Table Raised Condiment Rail models 8000N Preparation Table Raised Condiment Rail models 8000N model 8148N 8260N 8268N 8383N 835N 84111N Description: Available in six convenient sizes, 48 one door, 60 & 68 two door, 83 and 5 three door, and 111

More information

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Preventative Maintenance Tables

Preventative Maintenance Tables Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

Half Round Evaporators

Half Round Evaporators PRODUCT DATA & INSTALLATION Bullet T30-T-PDI-18 Part # 1047129 PRODUCT SUPPORT web: t-rp.com/truc email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Half Round Evaporators High Temperature Applications

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide BN-HGDTB June 2017 Replaces BN-HGDTB, March 2011 Mohave Technical Guide Table of Contents Overview... 2 System Features... 3 Condensing Unit... 4-18 Mohave Hot Gas Defrost Quick Reference... 5 AWEF Ratings...11

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

The Endura Series. The right combination of versatility, efficiency and reliability in foodservice equipment.

The Endura Series. The right combination of versatility, efficiency and reliability in foodservice equipment. The Endura Series The right combination of versatility, efficiency and reliability in foodservice equipment. With reach-ins, pass-thrus, roll-thrus, prep tables and heated cabinets, Endura is one of the

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat Electric (Modular) Heat Option 4.75 Kw, 7.5 kw, 9.5 kw, 14.25

More information

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

KR Series Air Defrost Unit Coolers Operating and Installation Manual

KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Vertical Upflow Horizontal Left Air Handlers

Vertical Upflow Horizontal Left Air Handlers Vertical Upflow Horizontal Left Air Handlers TWG018-060A 1½ 5 Ton PUB. NO. 22-1695-02-0301 (EN) Vertical Upflow Horizontal Left Air Handlers Features: Full line 1 1/2-5 tons Expanded application fit with

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

Exclusive design distributes cold air through a system of ducts and louvers positioned throughout the cabinet.

Exclusive design distributes cold air through a system of ducts and louvers positioned throughout the cabinet. COMMERCIAL SERIES REFRIGERATION K E Y F E AT U R E S HOSHIZAKI s attention to detail, continuous innovation, smart application of technology and commitment to the highest standards ensures that our customers

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TLV Low Velocity Evaporators

TLV Low Velocity Evaporators PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature

More information

Packaged refrigeration system Technical Guide

Packaged refrigeration system Technical Guide bn-ptmtb January 2008 Replaces bn-protb, 8/07 PRO 3 Top mount Packaged refrigeration system Technical Guide Model PTN and PTT For Indoor and Outdoor Applications Table of Contents Nomenclature...2 Features

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

KR Electrical Defrost Unit Coolers (PN E108318_E)

KR Electrical Defrost Unit Coolers (PN E108318_E) KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Central Chillers & Pump Tanks C E N T R A L C H I L L E R S 30RAP Series Central Chillers 10-60 Tons 30RAP Series air-cooled central

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information