HVAC HEATING PRODUCTS
|
|
- Alaina Morgan
- 6 years ago
- Views:
Transcription
1 GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS
2 Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3 Unit Number Description 3 Performance Data and Dimensional Data 4 Dimensional Data 5 TF/TC SERIES Standard/Optional Features 6 Unit Number Description 6 Performance and Dimensional Data TF Series 7 Performance and Dimensional Data TC Series 8 Performance Data TC Series 9 SF/SC SERIES Standard/Optional Features 0 Unit Number Description 0 Performance and Dimensional Data SF Series Performance and Dimensional Data SC Series 2 Performance Data SC Series 3 OPTIONAL ACCESSORIES All Series 4 HEAT THROW DATA All Series 5 NOZZLE DIMENSIONS 7 TYPICAL STANDARD SPECIFICATIONS GG Series 8 TF/TC Series 8 SF/SC Series 9 WARRANTY All Series 20 General Information STERLING TUBULAR DESIGN GAS FIRED UNIT HEATER The Sterling Tubular gas-fired unit heaters offer a highly efficient, extremely durable alternative to the traditional clam shell design. These units combine the latest tubular heat exchanger and inshot burner technology with the quality and reliability you have come to know from Sterling. HIGH EFFICIENCY Standard energy saving features like the direct spark ignition and power venting reduce standby losses and offer improved seasonal efficiencies. Tubular units certified by ETL as providing 83% thermal (combustion) efficiency. TUBULAR HEAT EXCHANGER The Sterling tubular heat exchanger has been designed to provide maximum and uniform heat transfer. The low pressure drop associated with this design enables heated air to be evenly distributed to the conditioned space. This curved, non-welded serpentine design experiences less thermally induced stress making it highly durable for significantly longer service life. All Sterling tubular heat exchangers are constructed of heavy duty 20-gauge aluminized steel. Optional 409 stainless steel heat exchangers are also available. DIRECT SPARK IGNITION SYSTEM Sterling Tubular units utilize a direct spark pilotless ignition of the burner, providing fast heat delivery. This highly reliable and efficient ignition system incorporates an integrated electronic control board to regulate the system sequence of operation, including an onboard LED indicator for simple troubleshooting. VENTING The Sterling Tubular unit heaters are ETL certified in accordance with categories I and III venting requirements. This certification allows units to be vented both vertically and horizontally using either single wall or double wall venting materials. This venting flexibility of the unit heater makes installation easier and more cost effective by allowing the installer to utilize existing venting components. CONTROL ACCESSIBILITY Designed with the service person in mind, every component of the Sterling unit heaters is easily accessible. Ignition and fan controls are located in one centrally located control panel. The access door provides control isolation as well as a pleasing exterior appearance. 0-YEAR WARRANTY Sterling warranties the heat exchanger, flue collector and burners of each unit heater to be free from defects in materials and workmanship for a period of 0 years from the date of manufacture. SEPARATED COMBUSTION - SF/SC SERIES The SF/SC series heater separates the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue products to the outside. The burners, pilot and flue system are enclosed within the unit; thus, the entire combustion process is unaffected by the atmosphere in the space where the heater is located. Separated combustion units are designed to be installed where dusty, dirty or mildly corrosive conditions exist or where high humidity or slightly negative pressure prevail. 2
3 GG Series Low Profile Unit Heater RESIDENTIAL AND COMMERCIAL CERTIFICATIONS The Sterling GG Series unit heater conforms with the latest ETL certification standards. Design certified under ANSI Z83.8 for Industrial/Commercial use and the more demanding requirements of CSA 0.96 USA (2nd ed.) Unit Heaters for Residential Installation, make this low profile unit heater the ideal selection. STANDARD FEATURES 82+% Thermal Efficiency Redundant Single-Stage Gas Valve Residential Certification 20/24V Control Transformer OSHA Fan Guard OPTIONAL FEATURES 409 Stainless Steel Heat Exchanger Two-Stage Gas Control (Sizes Only) Stainless Steel Flue Collector Unit Number Description 5//60 Fan Motor with Internal Overload Protection Direct Spark Ignition 20-Gauge Cabinet with Baked Enamel Finish 0 Year Heat Exchanger Warranty Supply Voltage (Field Mounted Transformers): 208//60 230//60 208/3/60 230/3/60 460/3/60 575/3/60 Right Hand Control Access - Field Convertible to Left Hand High Limit Switch Air Pressure Switch Natural or Propane Gas Gas Conversion Kit Included Vent Caps Totally Enclosed Motors (Sizes Only) Pressure Regulator ( 2 psi) Single & Two- Stage Mercury Free Thermostats Field Convertible to Separated Combustion Easy Access Control Panel 32 Stainless Steel Burner Box 20-Gauge Aluminized Heat Exchanger Power Vented Line Volt Thermostat Locking Thermostat Cover 24V SPST Relay Concentric Vent Kits (For All Separated Combustion Installations) Digit G X X X Item Prefix UT CA FT FM GT AL GC SV MT DL AS (Internal use Only), 2 - Unit Type [UT] GG - Residential Low Profile Tubular Propeller Note: Field conversion to Separated Combustion requires a Concentric Vent Kit. See Accessory Options X7-4 and X7-5 for proper unit selection. 3, 4, 5 - Capacity [CA] ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR 05-05,000 BTU/HR 20-20,000 BTU/HR 6 - Furnace Type [FT] A - Right Hand Access 7 - Furnace Material [FM]* - Standard (Aluminized) Steel Stainless Steel *Heat exchanger tube material only. 8 - Gas Type [GT] N - Natural Gas P - Propane (LP) Gas 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Gas Control [GC] A - Single Stage (Standard) B - Two Stage (Capacities [CA] 060 through 20 only) - Supply Voltage [SV] - 5// /3/ // /3/ // /3/ /3/60 Z - Other Note: Supply Voltage [SV] 2-7 include field mounted step down transformer. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed (Capacities [CA] 060 through 20 only) 3 - Development Level [DL] C - Production Onset 4, 5+ - Accessories [AS] FACTORY INSTALLED S3 - Stainless Steel Flue Collector Z - Special All Accessories are to be entered as a separate line item using catalog number which places AS as a prefix. i.e: A7 becomes AS-A7. FIELD INSTALLED (AS- ) A7 - Pressure Regulator -2 psi G - -Stage T87K Mercury Free Thermostat w/subbase Kit G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Thermostat w/subbase G9 - -Stage T822K Mercury Free Thermostat P5-24V SPST Relay-Specify Purpose VC-4-4" Vent Cap X7-4 - Concentric Vent Kit (Capacities [CA] ) X7-5 - Concentric Vent Kit (Capacities [CA] ) 3
4 CM GG Series Low Profile Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) PERFORMANCE DATA Input - BTU/Hr 30,000 45,000 60,000 75,000 90,000 05,000 20,000 (kw) (8.8) (3.2) (7.6) (22.0) (26.4) (30.8) (35.2) Output - BTU/Hr 24,900 37,350 49,800 6,500 73,800 86,00 98,400 (kw) (7.2) (0.9) (4.5) (8.0) (2.6) (25.2) (28.8) Thermal Efficiency - % Free Air Delivery - CFM ,00,300,475 (cu. m/s) (.75) (.260) (.349) (.434) (.59) (.64) (.696) Air Temperature Rise - F ( C) (5) (5) (5) (5) (5) (5) (5) Full Load Amps at 20V Maximum Circuit Ampacity MOTOR DATA: Motor HP 0 0 /2 /2 /0 /0 /0 Motor (kw) (0.04) (0.04) (0.06) (0.06) (0.075) (0.075) (0.075) Motor Type SP SP SP SP SP SP SP RPM Motor 5V DIMENSIONAL DATA - Inches (mm) A Jacket Height 2-3/8 2-3/8 5-7/8 5-7/8 22-5/8 22-5/8 22-5/8 (34) (34) (403) (403) (574) (574) (574) B Overall Height 3-/4 3-/4 6-3/6 6-3/6 23-9/6 23-9/6 23-9/6 (337) (337) (427) (427) (598) (598) (598) C Overall Depth 25-7/8 25-7/8 26-3/6 26-3/6 26-3/8 26-3/8 26-3/8 (632) (632) (665) (665) (670) (670) (670) D Center Line Height of Flue* /8 0-3/8 3-5/8 3-5/8 3-5/8 (26) (26) (263) (263) (346) (346) (346) D2 Center Line Height of Air Intake /8 8-5/8 8-5/8 (26) (26) (203) (203) (29) (29) (29) E Fan Diameter (254) (254) (356) (356) (406) (406) (406) F Discharge Opening Height 0-3/6 0-3/6 4-7/6 4-7/6 2-3/6 2-3/6 2-3/6 (275) (275) (367) (367) (538) (538) (538) G Vent Connection Diameter (02) (02) (02) (02) (02) (02) (02) H Center Line of Flue Connection From Side 7-/4 7-/4 7-/4 7-/ (84) (84) (84) (84) (97) (97) (97) H2 Center Line of Air Intake From Side (70) (70) (70) (70) (89) (89) (89) VENT SIZE REQUIREMENTS - STANDARD COMBUSTION Category III Horizontal - Inches (mm) (02) (02) (02) (02) (02) (02) (02) Category I & III Vertical - Inches (mm) (02) (02) (02) (02) (02) (02) (02) VENT SIZE REQUIRMENTS - SEPARATED COMBUSTION Exhaust Diameter** - Inches (mm) (02) (02) (02) (02) (27) (27) (27) Intake Air Diameter - Inches (mm) (02) (02) (02) (02) (27) (27) (27) Unit Weight - Lbs (kgs) (27) (29) (36) (39) (43) (48) (50) Shipping Weight - Lbs (kgs) (32) (34) (4) (43) (50) (52) (54) *For all installations, the flue collar is included with the unit and should be field installed per the instructions included with the unit. **4-5" reducer supplied where required. Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. 4
5 GG Series Low Profile Unit Heater Dimensional Data DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS 5
6 TF/TC Series Tubular Unit Heater STANDARD FEATURES In-Shot Burner Main Control Design Panel 20-Gauge Steel Jacket with Baked Enamel Finish 5//60 Supply Voltage Direct Spark Ignition OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners and/or and 230, 460, Flue Collector 575/3/60 Redundant Single-Stage Gas Valve 5/24 Volt Control Transformer Premium Efficiency Blower Motors in ODP and TE Types Individually Adjustable and Removable Louvers Power Vented Two-Stage and Various Electronic Modulation Gas Controls 5//60 Volt Motor with Internal Overload Protection Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly 0 Year Heat Exchanger, Flue Collector and Burner Warranty 82+% Thermal Efficiency Unit Number Description TF Series Digit T X X X Item Prefix UT CA FT FM GT AL GC SV MT AS (Internal use Only) TC Series Digit T X X X Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only), 2 - Unit Type [UT] TF - Tubular Propeller TC - Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5// /3/ // /3/ // /3/ /3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers only) 4 - Premium Efficiency, Totally Enclosed (Blowers only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor L - HP C - HP w/contactor P - HP w/magnetic Starter D - HP w/contactor R - HP w/magnetic Starter F - HP w/contactor S - HP w/magnetic Starter G - - HP w/contactor T - - HP w/magnetic Starter H - 2 HP w/contactor U - 2 HP w/magnetic Starter J - /4 HP W - /4 HP w/magnetic Starter **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 3/4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers only) M8 - Discharge Duct Flange Assembly (Blowers only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity ) M2-3 - Vent Caps (6") (Unit Capacity ) F - -Stage T675A Ductstat F2-2-Stage T678A Ductstat P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat w/subase Kit G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Stat w/subbase G9 - -Stage T822K Mercury Free Thermostat X2-30 Degree Downturn Nozzle X3-60 Degree Downturn Nozzle X4-90 Degree Downturn Nozzle X5 - Vertical Louver Kit 6
7 CM TF Series Tubular Propeller Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75, , , , , ,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66, , , , ,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V MOTOR DATA: Motor HP (Qty.) /0 /4 /4 /3 /3 /3 (2) /4 (2) /3 (2) /3 Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,50,40,40,40,40,40,40,40,40 5V DIMENSIONAL DATA - Inches (mm) A Overall Height to Top of Flue (857) (857) (857) (857) (857) (857) (864) (864) (864) B Jacket Width of Unit (527) (527) (527) (83) (83) (83) (289) (289) (289) C Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) D Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) E Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) F Discharge Opening Width (476) (476) (476) (78) (78) (78) (238) (238) (238) G Depth to CL Flue /8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) H Discharge Opening Height (622) (622) (622) (622) (622) (622) (622) (622) (622) L Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) *Vent Size Diameter - Inches (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Fan Diameter - Inches (Qty.) (2) 6 (2) 8 (2) 8 Gas Inlet-Natural Gas (Inches) Gas Inlet- LP Gas (Inches) OR OR OR OR Approximate Unit Weight - Lbs (kg) (60) (66) (70) (87) (9) (96) (39) (45) (52) Approximate Ship Weight - Lbs (kg) (78) (84) (88) (09) (4) (8) (66) (73) (79) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8" (35) (Hanging) C E (Hanging) Flue * D G -5/8" (295) (Hanging) 32-" (826) L B H (Discharge Opening) 33" A D467 DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS D467 Electrical Control Panel Gas Valve F (Discharge Opening) Rear View Side View Front View " (25) 7
8 CM TC Series Tubular Blower Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75, , , , , ,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66, , , , ,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V Maximum Circuit Ampacity MOTOR DATA Motor HP /4 - - Motor kw Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 5V DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 2-25/32 22-/32 22-/32 25-/32 25-/32 25-/ /32 25-/32 25-/32 (553) (560) (560) (644) (644) (644) (663) (644) (644) "G" Discharge Opening Width (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue /8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Discharge Opening Height (622) (622) (622) (622) (622) (622) (622) (622) (622) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth /6 53-7/32 59-/6 59-/6 59-/6 56-7/6 59-/6 59-/6 (340) (35) (352) (56) (56) (56) (434) (56) (56) *Vent Size Diameter - Inches (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Blower Size - Inches (Qty) (2) 2 (2) 2 (2) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs (kg) (78) (79) (92) () (20) (3) (68) (77) (95) Approximate Ship Weight - Lbs (kg) (6) (8) (3) (73) (8) (93) (236) (248) (270) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed H per included instructions. /8 E 32 M ** LEGEND: SPH = SPLIT PHASE C CAP. START = CAPACITOR START F D B Flue 33 L (Discharge Opening) A 8 D893 Electrical Control Panel Gas Valve G (Discharge Opening) P Rear View Side View Front View
9 TC Series Tubular Blower Unit Heater Performance Data Unit TC00 TC25 TC50 TC75 TC200 TC250 TC300 TC350 TC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches WP (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) /4 /4 /4 /4 / (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) /4 /4 /4 /4 / (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) /4 /4 /4 /4 / (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) (0) (.8) (0.75) (0.75) (.) (.) (.) (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) (0) (2.4) (0.75) (0.75) (.) (.) (.) (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) (0) (2.54) (.) (.) (.) (.) (.) (5.5) (2.) (.) (.) (.) (.) (.) (2.) (.8) (.) (.) (.) (.) (.) (26.6) (.59) (.) (.) (.) (.) (.) (0) (2.9) (.) (.) (.) (.) (.49) (5.5) (2.4) (.) (.) (.) (.) (.) (2.) (2.07) (.) (.) (.) (.) (.) (26.6) (.8) (.) (.) (.) (.) (.) 9
10 SF/SC Series Separated Combustion Unit Heater STANDARD FEATURES Enclosed 5/24 Volt Combustion Control System Transformer 20-Gauge Aluminized Steel Tubular Heat Exchanger 83% Thermal Efficiency Combustion Air Pressure Switch OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners, and/or and 208, 230, Flue Collector 460, 575/3/60 ODP Motor (with Overload Protection) Redundant Single-Stage Gas Valve Two-Stage and Various Electronic Modulation Gas Controls Unit Number Description 20-Gauge Steel Cabinetry with Baked Enamel Finish Direct Spark Ignition System 5//60 Supply Voltage Premium Efficiency Blower Motors in ODP & TE Types Digit T X X X Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only) Rear Burner Access Power Vented Individually Adjustable and Removable Horizontal Louvers Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly Complete Belt /Fan Guard Main Control Panel 0 Year Heat Exchanger, Flue Collector and Burner Warranty Combustion Air Inlet Kits (allows concentric venting with horizontal or vertical termination), 2 - Unit Type [UT] SF - Separated Combustion Tubular Propeller SC - Separated Combustion Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR ,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5// /3/ // /3/ // /3/ /3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers Only) 4 - Premium Efficiency, Totally Enclosed (Blowers Only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor P - HP w/magnetic Starter C - HP w/contactor R - HP w/magnetic Starter D - HP w/contactor S - HP w/magnetic Starter F - HP w/contactor T - - HP w/magnetic Starter G - - HP w/contactor U - 2 HP w/magnetic Starter H - 2 HP w/contactor W - /4 HP w/magnetic Starter J - /4 HP 0 - None/Not Applicable L - HP **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers Only) M8 - Discharge Duct Flange (Blowers Only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity ) M2-3 - Vent Caps (6") (Unit Capacity ) F - -Stage T675A Ductstat (Blowers Only) F2-2-Stage T678A Ductstat (Blowers Only) P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat X2-30 Degree Downturn Nozzle w/subase Kit X3-60 Degree Downturn Nozzle G2 - -Stage T87K Mercury Free Thermostat X4-90 Degree Downturn Nozzle w/tg5a Guard Kit X5 - Vertical Louver Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch X7-H5 - Horiz. Combustion Air Inlet Kit, 5 inch G5-2-Stage TH5220D Mercury Free (Unit Capacity ) Thermostat w/subbase X7-H6 - Horiz. Combustion Air Inlet Kit, 6 inch G6 - Locking Thermostat Cover (Unit Capacity ) G8 - -Stage T669C Line Voltage Stat X7-V5 - Vert. Combustion Air Inlet Kit, 5 inch w/subbase (Unit Capacity ) G9 - -Stage T822K Mercury Free X7-V6 - Vert. Combustion Air Inlet Kit, 6 inch Thermostat (Unit Capacity ) 0
11 CM SF Series Separated Combustion Propeller Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75, , , , , ,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66, , , , ,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V MOTOR DATA: Motor HP (Qty) /0 /4 /4 /3 /3 /3 /4 (2) /3 (2) /3 (2) Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,050,40,40,40,40,40,40,40,40 5V DIMENSIONAL DATA - Inches (mm) "A" Overall Height to Top of Flue (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit (527) (527) (527) (83) (83) (83) (289) (289) (289) "C" Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Discharge Opening Width (476) (476) (476) (78) (78) (78) (238) (238) (238) "G" Depth to CL Flue /8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) *Vent Size Diameter - Inches (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs (kg) (6) (67) (7) (88) (93) (97) (4) (47) (54) Approximate Ship Weight - Lbs (kg) (79) (85) (89) () (5) (20) (68) (75) (8) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8' (35mm) (Hanging) E (Hanging) C Flue D G -5/8 (295mm) (Hanging) 32-' (826mm) L B 33" (838mm) 24- (622mm) (Discharge Opening) A D9067 Electrical Control Panel Gas Valve F (Discharge Opening) " (25mm) Rear View Side View Front View
12 CM SC Series Separated Combustion Blower Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75, , , , , ,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66, , , , ,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V Maximum Circuit Ampacity MOTOR DATA: Motor HP /4 - - Motor kw Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 5V DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 2-25/32 22-/32 22-/32 25-/32 25-/32 25-/ /32 25-/32 25-/32 (553) (560) (560) (644) (644) (644) (663) (644) (644) "G" Discharge Opening Width (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue /8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth /6 53-7/32 59-/6 59-/6 59-/6 56-7/6 59-/6 59-/6 (340) (35) (352) (56) (56) (56) (434) (56) (56) *Vent Size Diameter - Inches (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs (kg) (78) (80) (92) (2) (2) (32) (70) (79) (96) Approximate Ship Weight - Lbs (kg) (7) (9) (32) (74) (83) (94) (238) (250) (272) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SPH = SPLIT PHASE CAP. START = CAPACITOR START /8 (29mm) C E Flue F H 32 (826mm) D M B 33 (838mm) 24 (622mm) (Discharge Opening) A Electrical Control Panel Gas Valve P G (Discharge Opening) 2 Rear View Side View Front View D9050
13 SC Series Separated Combustion Blower Performance Data Unit SC00 SC25 SC50 SC75 SC200 SC250 SC300 SC350 SC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches WP (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) /4 /4 /4 /4 / (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) /4 /4 /4 /4 / (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) /4 /4 /4 /4 / (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) (0) (.8) (0.75) (0.75) (.) (.) (.) (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) (0) (2.4) (0.75) (0.75) (.) (.) (.) (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) (0) (2.54) (.) (.) (.) (.) (.) (5.5) (2.) (.) (.) (.) (.) (.) (2.) (.8) (.) (.) (.) (.) (.) (26.6) (.59) (.) (.) (.) (.) (.) (0) (2.9) (.) (.) (.) (.) (.49) (5.5) (2.4) (.) (.) (.) (.) (.) (2.) (2.07) (.) (.) (.) (.) (.) (26.6) (.8) (.) (.) (.) (.) (.) 3
14 Accessories [AC] FACTORY INSTALLED M6 - OSHA TYPE FAN GUARD Series TF, SF Factory installed available on series TF and SF only, standard on series GG. Required for installations that must conform to OSHA standards. Also known as fingerproof fan guards. M8 - DISCHARGE DUCT FLANGE ASSEMBLY Series TC, SC Factory Installed (Specify No Charge) Used in lieu of louvers on blower units for incorporating field duct work. P4 - TERMINAL BLOCK WIRING Series TF, TC, SF, SC Factory Installed Provides specific terminal designation for field wiring. P6 - SUMMER/WINTER SWITCH Series TF, TC, SF, SC Factory Installed Allows operation of fan or blower for ventilating purposes during hot summer months (manually operated). S3 - STAINLESS STEEL FLUE COLLECTOR Factory Installed 409 Stainless steel flue collector in lieu of standard aluminized steel collector. S5 - STAINLESS STEEL BURNERS Series TF, TC, SF, SC Factory Installed 304L Stainless steel in-shot burners in lieu of the standard aluminized steel in-shot burners. FIELD INSTALLED A7 - PRESSURE REGULATOR -2 PSI All Series & Sizes Required where main line pressure exceeds 4" WC ( psig), must specify incoming pressure when ordered. One regulator per unit required, shipped separately. F - ONE STAGE DUCTSTAT Series TC, SC Single pole, double throw F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] F2 - TWO STAGE DUCTSTAT Series TC, SC Single pole, double throw F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] G - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH SUBBASE Single stage heating thermostat with subbase. Includes fan switching relay. Standard round styling suitable for any decor F range. G2 - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH TG5A GUARD Same features as G except a tamper proof guard is included. G3 - ONE STAGE T834N (MERCURY-FREE) THERMOSTAT WITH FAN SWITCH Single stage heating thermostat with fan switch. Manufactured exclusively for Sterling with a Sterling logo face plate F range. [2-3/8" W x 4-" H x -" D] G5 - TWO STAGE TH5220D (MERCURY-FREE) THERMOSTAT WITH SUBBASE Two stage heating and two stage cooling with system and fan switching and built in 0 F heating/cooling differential. Includes fan relay. Heating F range, Cooling F. [5-3/6" W x 3-9/6" H x -" D] G6 - LOCKING THERMOSTAT COVER Universal locking thermostat cover for use with all thermostats listed. G8 - ONE STAGE T669C LINE VOLTAGE STAT WITH SUBBASE Single stage heating only thermostat. 5 volt operation F range [4-" W x 4-5/8" H x -7/8" D] G9 - ONE STAGE T822K (MERCURY-FREE) THERMOSTAT Single stage heating only thermostat with subbase. 24 volt operation F range. [2-7/8" W x 4-" H x -" D] M2-2, 3 - VENT CAP Series TF, TC, SF, SC 5 or 6 inch vent cap for use with series TF, TC, SF, SC. Must indicate unit size when ordered. P5-24 VOLT RELAY Specify purpose. 24 volt SPST relay. VC - 4 VENT CAP Series GG 4" vent cap for use with series GG. X2-30 NOZZLE Directs the discharge air at a 30 angle. Air can be directed up to 60 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X3-60 NOZZLE Directs the discharge air at a 60 angle. Air can be directed up to 90 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X4-90 NOZZLE Directs the discharge air at a 90 angle. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X5 - VERTICAL LOUVER KIT Series TF, TC, SF, SC Vertical Louvers to provide 4 way air deflection. Must indicate unit size when ordered. X7-4, 5 CONCENTRIC VENT KIT Series GG Allows for one 6 or 8" vent/combustion air opening through a structure. One kit permits for either horizontal or vertical applications. Kit required for converting a series GG to separated combustion. X7 - H5, H6 HORIZONTAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" horizontal vent/ combustion air opening through a structure. Must indicate unit size when ordered. X7 - V5, V6 VERTICAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" vertical vent/ combustion air opening through a structure. Must indicate unit size when ordered. 4
15 Heat Throw Data NOTES:. All throw data figures are approximations. Allowances should be made for optimum performance, altitude, etc. 2. NR - Units not recommended at these mounting heights , 60 and 90 nozzles are shipped unassembled. STANDARD UNIT HEATER APPLICATIONS 30 NOZZLE Distance From Floor to Bottom of Unit H Approximate Distance of Heat Throw - Feet (Meters) Ft. 30,000 45,000 60,000 75,000 (m) (8.8) (3.2) (7.6) (22.0) (2.4) (0.) (0.) (0.) (2.2) (3.0) (8.5) (8.5) (8.5) (0.7) 2 (3.7) NR NR NR NR 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) (2.4) (2.2) (8.3) (8.3) (9.8) (3.0) (0.7) (6.5) (6.5) (7.) NR (3.7) (3.4) (3.4) (4.0) 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR 25,000 50,000 75, ,000 (36.6) (43.9) (5.2) (58.6) (2.4) (9.8) (2.3) (22.9) (24.4) (3.0) (7.) (8.3) (9.5) (20.7) (3.7) (4.0) (4.9) (7.4) (8.6) NR (4.6) (3.7) (4.9) (5.8) NR NR NR (6.) (4.0) 250, , , ,000 (73.2) (87.8) (02.5) (7.) (2.4) (27.4) (32.0) (33.5) (36.6) (3.0) (23.8) (27.4) (29.0) (30.5) (3.7) (20.7) (24.4) (25.6) (27.4) (4.6) (8.3) (2.3) (22.6) (24.4) (6.) (6.5) (9.2) (20.) (2.3) Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) Approximate Distance of Heat Throw - Feet (Meters) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 65 Data Not Data Not (2.4) Available (9.8) Available Available 0 Data Not 57 Data Not Data Not (3.0) Available (7.4) Available Available 2 Data Not 50 Data Not Data Not (3.7) Available (5.2) Available Available 5 Data Not Data Not Data Not NR (4.6) Available Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available 25,000 50,000 75, ,000 (36.6) (43.9) (5.2) (58.6) (2.4) (2.3) (22.9) (24.4) (25.9) (3.0) (8.3) (9.5) (20.7) (2.9) (3.7) (6.5) (7.4) (8.3) (9.5) (4.6) (3.7) (4.6) (5.2) (6.2) NR NR (6.) (3.4) (4.3) 250, , , ,000 (73.2) (87.8) (02.5) (7.) (2.4) (29.0) (35.) (36.6) (38.) (3.0) (26.2) (30.2) (32.0) (33.5) (3.7) (23.5) (26.8) (28.7) (30.5) (4.6) (9.5) (22.6) (24.) (25.6) (6.) (7.7) (20.) (2.6) (22.9) 5
16 Heat Throw Data Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) 60 NOZZLE Approximate Distance of Heat Throw (Feet) Approximate Distance of Heat Throw - Feet (Meters) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 75 Data Not Data Not (2.4) Available (22.9) Available Available 0 Data Not 65 Data Not Data Not (3.0) Available (9.8) Available Available 2 Data Not 60 Data Not Data Not (3.7) Available (8.3) Available Available 5 Data Not 50 Data Not Data Not (4.6) Available (5.2) Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available 25,000 50,000 75, ,000 (36.6) (43.9) (5.2) (58.6) (2.4) (24.4) (25.9) (27.4) (29.0) (3.0) (2.3) (22.9) (24.) (25.3) (3.7) (9.5) (20.7) (2.9) (23.2) (4.6) (6.5) (7.) (8.6) (9.8) (6.) (4.9) (5.8) (6.8) (8.0) 250, , , ,000 (73.2) (87.8) (02.5) (7.) (2.4) (33.5) (38.) (39.6) (42.) (3.0) (29.0) (33.2) (35.) (36.6) (3.7) (25.6) (30.5) (3.4) (32.9) (4.6) (2.6) (25.9) (26.8) (28.7) (6.) (9.8) (23.5) (24.7) (25.9) Distance From Floor to Bottom of Unit H Ft. (m) 0 90 NOZZLE* Approximate Distance of Heat Throw - Feet (Meters) 00,000 25,000 50,000 (29.3) (36.6) (43.9) NR NR NR (3.0) (4.6) (9.) x (7.6) (0.7) x (9.) (2.2) x (0.7) 20 (6.) NR NR NR 25 (7.6) NR NR NR 30 (9.) NR NR NR 75, , ,000 (5.2) (58.6) (73.2) 0 (3.0) NR NR NR (4.6) (3.7) x (2.2) (5.2) x (2.2) (8.3) x (3.7) NR (6.) (2.2) x (0.7) (7.) x (2.2) NR NR (7.6) (5.2) x (0.7) 30 (9.) NR NR NR 300, , ,000 (87.8) (02.5) (7.) 0 NR NR NR (3.0) (4.6) (2.3) x (3.7) (24.4) x (5.2) (30.5) x (5.2) (6.) (9.8) x (2.2) (2.3) x (3.7) (24.4) x (3.7) (7.6) (8.3) x (0.7) (9.8) x (2.2) (22.9) x (2.2) (9.) (6.8) x (0.7) (8.3) x (0.7) (9.8) x (2.2) *It is not recommended to mount a unit with a 90 nozzle at 0 feet or less. Heat Throw data for GG Series units with a 90 nozzle installed is not currently available. 6
17 Nozzle Dimensions* A C A C B D B 30 NOZZLE 60 NOZZLE A C D B 90 NOZZLE *Nozzles are field assembled. NOZZLE DIMENSIONAL DATA CHART DIMENSION NOZZLE TYPE 30, 45 60, 75 90, 05, 20 00, 25, 50 75, 200, , 350, /8 9-5/8 9-5/ WIDTH (498) (498) (498) (527) (832) (289) A 9-5/8 9-5/8 9-5/ In. (498) (498) (498) (527) (832) (289) (mm) 9-5/8 9-5/8 9-5/ (498) (498) (498) (527) (832) (289) 2-/6 5-5/8 22-3/ HEIGHT (306) (397) (568) (800) (800) (800) B 2-/6 5-5/8 22-3/ In. (306) (397) (568) (800) (800) (800) (mm) 2-/6 5-5/8 22-3/ (306) (397) (568) (800) (800) (800) 3-/8 3-/8 3-/ FURTHEST 30 (333) (333) (333) (38) (38) (38) DEPTH 22-3/6 22-3/6 22-3/ C 60 (564) (564) (564) (648) (648) (648) In. (mm) 25-9/6 25-9/6 25-9/6 28-/4 28-/4 28-/4 90 (694) (694) (694) (78) (78) (78) HEIGHT WITH OVERHANG D In. (mm) 30 N/A /6 6-7/8 23-5/ (338) (429) (600) (762) (762) (762) 5-/4 8-3/6 25-9/ (387) (478) (649) (864) (864) (864) 7
HVAC HEATING PRODUCTS
GTFC-8 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series QVSD Series GAS-FIRED HEATING EQUIPMENT Tubular Unit Heaters Duct Furnaces Cabinet Blowers Contents PAGE GENERAL INFORMATION Tubular
More informationGas-Fired Heating Equipment
BTUC- GAS-FIRED UNIT HEATERS BSF/BSC Series BTU/BTC Series BRT Series Gas-Fired Heating Equipment Tubular Unit Heaters Duct Furnaces Contents PAGE Tubular Unit Heaters GENERAL INFORMATION Tubular Unit
More informationHVAC HEATING PRODUCTS Application Manual
GTFC- HVAC HEATING PRODUCTS Application Manual HU Series TF/TC Series GG Series GAS-FIRED HEATING EQUIPMENT High Efficiency Unit Heaters Tubular Unit Heaters Duct Furnaces Cabinet Blowers Unit Heaters
More informationBTUC-4 TUBULAR GAS-FIRED UNIT HEATERS
BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS Table of Contents Models BTU & BRU General Information 3 Performance and Dimensional Data 4, 5 Model Number Description 6 Model BST General Information 7 Performance
More informationGQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.
GQVC-12 HVAC EQUIPMENT GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. 80% thermal efficiency. Heat Exchangers have a tough job to do. It's no
More informationProduct Catalog Gas Heating Products: Indoor and Outdoor Units
Product Catalog Gas Heating Products: Indoor and Outdoor Units Indirect Fired, Direct Fired, and Gas Unit Heaters March 2017 UH-PRC004B-EN Copyright Thisdocumentand the informationinitare the propertyof
More informationSUBMITTAL SCHEDULE & DATA
SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model
More informationbring value to your space
PTP unit heaters can use natural or propane gas, and are available in single-stage or optional two-stage controls. bring value to your space with THE NEW PTP HEATER. Introducing the new power vented, PTP
More informationHVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22
HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22 HVAC EQUIPMENT 99% * Thermal Efficiency Gas-Fired Unit Heaters Sterling s Nexus brings gas-fired unit heaters to unprecedented
More informationGAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS
GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS MODEL HD MODEL HDB MODEL HD MODEL HDB MODEL PDP MODEL BDP MODEL PTP 6-189.11 MAY, 2017 TABLE OF CONTENTS Modine s power vented unit heaters
More informationGas-Fired Power Vented Unit Heaters Propeller & Blower Models
July, 2009 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating requirements
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationSUH-8 UNIT HEATERS. High Efficiency Heating Equipment
SUH-8 UNIT HEATERS High Efficiency Heating Equipment Efficient Heating Solutions for all Applications Sterling unit heaters provide efficient heating solutions for all residential and commercial applications.
More informationUNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)
UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This
More informationHVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-20
HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-20 HVAC EQUIPMENT 99% * Thermal Efficiency Gas-Fired Unit Heaters Sterling s Nexus brings gas-fired unit heaters to unprecedented
More informationGas-Fired Indoor and Outdoor Duct Furnaces
July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete
More informationHIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES
PRICE SHEET: NXPS-3 EFFECTIVE: July 1, 2018 SUPERSEDES: NXPS-2 HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES ITEM PAGE HU Series Unit Number Description...2 HU Series...3 Options...4 Options - Accessories,
More informationRefer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents
TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial
More informationModel UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED
Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.
More informationInstallation, Operation and Maintenance
Installation, Operation and Maintenance Tubular Gas Fired Blower Style Unit Heater Model: GBNE SAFETY Only qualified personnel should install and service the equipment. The installation, starting up, and
More informationT-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh
PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206
More informationUNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil
UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller
More informationGas-Fired Power Vented Unit Heaters Propeller & Blower Models
6-189.6 August, 2011 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating
More informationGAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL
GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,
More informationGAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL
GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationGas-Fired Unit Heaters Commercial & Industrial
November 2007 Gas-Fired Unit Heaters Commercial & Industrial Model PSH Model BSH GAS-FIRED SEPARATED COMBUSTION UNIT HEATERS Table of Contents Page I. Design Benefits A. Application, Design, Construction
More informationAUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters
6-170.4 AUGUST, 01 High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters INTRODUCTION / TABLE OF CONTENTS At 9% thermal efficiency for all model sizes, Modine s Effinity 9 condensing unit
More informationAHC-2. OUTDOOR AIR HANDLERS Application Manual
AHC-2 OUTDOOR AIR HANDLERS Application Manual Contents 2 PAGE GENERAL INFORMATION 2 FEATURES AND BENEFITS 3 UNIT NUMBER DESCRIPTION 4 AIR HANDLER SELECTION 5 AIR HANDLER 5,6 PACKAGED ROOFTOP ARRANGEMENTS
More informationModel GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES
SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More informationINFRARED RADIANT HEATERS
IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design
More informationProduct Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input
Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the
More informationFOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS FOR COMMERCIAL, INDUSTRIAL AND RESIDENTIAL INSTALLATIONS ATTENTION: READ THIS MANUAL AND ALL LABELS
More informationUpflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA
More informationGARAGE / WORKSHOP INFRARED HEATERS
GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways
More informationCOMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh
GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input
More informationKG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency
More informationTUBULAR GAS-FIRED BLOWER STYLE UNIT HEATER
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION TUBULAR GAS-FIRED BLOWER STYLE UNIT HEATER TBII-4 J30-08867 ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE ATTEMPTING
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationLine Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas
HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000
More informationTUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS DSTBIM-15 J30-06939 ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE
More informationRG7D 1-Stage Heat Series
TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace
More informationG6RC Series TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl
More informationFSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces
SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications
More informationGAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP
GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance
More informationGas-Fired Indoor and Outdoor Duct Furnaces
October, 2010 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY AND POWER VENTED DFG/DFP, DBG/DBP, DCG/DCP INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series
More informationFor More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationUpflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO
Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15
More informationTUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS DSTBIM-12 J30-06939 ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE
More informationM3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially
More informationADF/ADFH 300 and 500
MODEL ADF/ADFH DIRECT-FIRED SYSTEMS TECHNICAL DATA Four Sizes - 300, 500, 700, 1200 Horizontal Configuration with Full Curb Cap Base Horizontal or Vertical (down) Discharge Indoor/Outdoor Installation
More informationGUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS
GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based
More informationSEPARATED COMBUSTION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION SEPARATED COMBUSTION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS STPIM-4 J30-09054 ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE
More information80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationDownflow/Horizontal Right Induced Draft Gas Furnace
Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion
More informationINDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG
INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 20-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons
More informationFG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage
More informationG I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY
G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 60-120 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationUpflow/Horizontal Condensing, Gas-Fired Furnace
Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System
More informationUpflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace
Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE
More informationGas-Fired Unit Heaters Commercial & Industrial
6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial
More informationMERIT SERIES Downflow
PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL
More informationRuud Achiever Series Multi position Gas Furnaces
Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationKG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace
More informationINSTALLATION INSTRUCTIONS AND PARTS LIST TUBULAR GAS FIRED PROPELLER UNIT HEATERS
INSTALLATION INSTRUCTIONS AND PARTS LIST TUBULAR GAS FIRED PROPELLER UNIT HEATERS TBIM-6 J30-05394C ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE ATTEMPTING TO INSTALL,
More informationFOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
INSTALLATION INSTRUCTIONS AND PARTS IDENTIFICATION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS FOR COMMERCIAL, INDUSTRIAL AND RESIDENTIAL INSTALLATIONS ATTENTION: READ THIS MANUAL AND ALL LABELS
More informationGMS9/GCS9 SERIES 93% AFUE
GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.
More informationUpflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV
Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion
More information80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The
More informationThermal Efficiency Gas-Fired High Efficiency Unit Heater
99% * Thermal Efficiency Gas-Fired High Efficiency Unit Heater The World's Best High Efficiency Unit Heater The less fossil fuels we burn the better it is for our future; all of my designs concentrate
More informationFORM NO. G REV. 4 Supersedes Form No. G Rev. 3
FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace
More informationTrue performance and rugged durability. TU, LF and LD Models
Unit heaters/ Duct furnaces True performance and rugged durability TU, LF and LD Models Separated Combustion Unit Heaters at a glance: Ideal for hard-to-heat applications requiring fresh air for combustion
More informationInstallation, Operation, and Maintenance
Installation, Operation, and Maintenance Gas Unit Heater Separated Combustion Gas-Fired Propeller Unit Heater SAFETY Only qualified personnel should install and service the equipment. The installation,
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are
More informationFOR YOUR SAFETY. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
INSTALLATION INSTRUCTIONS AND PARTS LIST TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS FOR RESIDENTIAL INSTALLATIONS B-GG-IOM-6 J30-08611 ATTENTION: READ THIS MANUAL AND ALL LABELS ATTACHED TO
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are
More informationModular Heating & Ventilating Unit Model IGX-HV
Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE
More informationW92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )
FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential
More informationIndustrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation
Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationRuud Achiever Plus Series Multi-position Gas Furnaces
Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationUpflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE
Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationDirect Gas-Fired Make-Up Air
Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G11-450 REV. 13 Supersedes Form No. G11-450 Rev. 12 GAS FURNACES /RGRB- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. GSC-534 GF901U SERIES Models with Input Rates 45, 60, 75, 90, 105 & 120 kbtu [13.19, 17.58, 21.9, 26.4, 30.77 & 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY UPFLOW GAS FURNACES The
More informationGAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationU n i t H e at e r s
Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design
More informationFORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES
FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace R802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationRuud Acheiver Series Upflow Gas Furnaces
Gas Furnaces Ruud Acheiver Series Upflow Gas Furnaces RGRC- Series 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More information