1 Hot Melt Applicators Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY

2 Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note This is a Nordson corporation publication which is protected by copyright. Copyright No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice All rights reserved. - Translation of Original - Trademarks AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Autotech, Baitgun, Blue Box, Bowtie, Build A Part, CanWorks, Century, CF, CleanSleeve, CleanSpray, Color on Demand, ColorMax, Control Coat, Coolwave, Cross Cut, cscan+, Dage, Dispensejet, DispenseMate, DuraBlue, DuraDrum, Durafiber, DuraPail, Dura Screen, Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo Coat, e.dot, EFD, Emerald, Encore, ESP, e stylized, ETI stylized, Excel 2000, Fibrijet, Fillmaster, FlexiCoat, Flexi Spray, Flex O Coat, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Fulfill, GreenUV, HDLV, Heli flow, Helix, Horizon, Hot Shot, icontrol, idry, iflow, Isocoil, Isocore, Iso Flo, itrax, JR, KB30, Kinetix, KISS, Lean Cell, Little Squirt, LogiComm, Magnastatic, March, Maverick, MEG, Meltex, Microcoat, Micromark, Micromedics, Micro Meter, MicroSet, Microshot, Millenium, Mini Blue, Mini Squirt, Moist Cure, Mountaingate, MultiScan, NexJet, No Drip, Nordson, Optimum, Package of Values, Paragon, PatternView, PermaFlo, PICO, PicoDot, PluraFoam, Porous Coat, PowderGrid, Powderware, Precisecoat, PRIMARC, Printplus, Prism, ProBlue, Prodigy, Pro Flo, Program A Bead, Program A Shot, Program A Stream, Program A Swirl, ProLink, Pro Meter, Pro Stream, RBX, Rhino, Saturn, Saturn with rings, Scoreguard, SC5, S. design stylized, Seal Sentry, Sealant Equipment & Engineering, Inc., SEE and design, See Flow, Select Charge, Select Coat, Select Cure, Servo Flo, Shot A Matic, Signature, Slautterback, Smart Coat, Smart Gun, Solder Plus, Spectrum, Speed Coat, Spraymelt, Spray Squirt, Super Squirt, SureBead, Sure Clean, Sure Coat, Sure Max, Sure Wrap, Tela Therm, Tip Seal, Tracking Plus, TRAK, Trends, Tribomatic, TrueBlue, TrueCoat, Tubesetter, Ultra, UniScan, UpTime, u TAH, Value Plastics, Vantage, Veritec, VersaBlue, Versa Coat, VersaDrum, VersaPail, Versa Screen, Versa Spray, VP Quick Fit, Walcom, Watermark, When you expect more., X Plane are registered trademarks - - of Nordson Corporation. Accubar, Active Nozzle, Advanced Plasma Systems, AeroDeck, AeroWash, Allegro, AltaBlue, AltaSlot, Alta Spray, AquaCure, Artiste, ATS, Auto Flo, AutoScan, Axiom, Best Choice, BetterBook, Blue Series, Bravura, CanNeck, CanPro, Celero, Chameleon, Champion, Check Mate, ClassicBlue, Classic IX, Clean Coat, Cobalt, ContourCoat, Controlled Fiberization, Control Weave, CPX, cselect, Cyclo Kinetic, DispensLink, DropCure, Dry Cure, DuraBraid, DuraCoat, e.dot+, E Nordson, Easy Clean, EasyOn, EasyPW, Eclipse, Equalizer, Equi=Bead, Exchange Plus, FillEasy, Fill Sentry, Flow Coat, Fluxplus, Freedom, G Net, G Site, Genius, Get Green With Blue, Gluie, Ink Dot, IntelliJet, ion, Iso Flex, itrend, KVLP, Lacquer Cure, Maxima, Mesa, MicroFin, MicroMax, Mikros, MiniEdge, Minimeter, MonoCure, Multifil, MultiScan, Myritex, Nano, OmniScan, OptiMix, OptiStroke, Optix, Origin, Partnership+Plus, PatternJet, PatternPro, PCI, PharmaLok, Pinnacle, Plasmod, PluraMix, Powder Pilot, Powder Port, Powercure, Process Sentry, Pulse Spray, PURBlue, PURJet, PurTech, Quad Cure, Quantum, Ready Coat, RediCoat, RollVIA, Royal Blue, Select Series, Sensomatic, Shaftshield, SheetAire, Smart, Smartfil, SolidBlue, Spectral, Spectronic, SpeedKing, Spray Works, StediFlo, StediTherm, Summit, Sure Brand, SureFoam, SureMix, SureSeal, Swirl Coat, TAH, Tempus, ThruWave, TinyCure, Trade Plus, Trilogy, Ultra FoamMix, UltraMax, Ultrasaver, Ultrasmart, Universal, ValueMate, Versa, Viper, Vista, WebCure, YESTECH, 2 Rings (Design) are trademarks - - of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners' right.

3 Table of Contents I Table of Contents Safety Instructions... 1 Introduction... 1 Intended Use... 1 Unintended Use - Examples Residual Risks... 2 Note on Manual... 2 Definition of Terms... 2 Applicator... 2 Melter... 2 Control Module... 2 Applicator Components... 3 Function... 4 Side Gluing... 4 Volume Control... 5 Heating... 5 Overtemperature Shutdown by Thermostat... 5 ID Plate... 5 Installation... 6 Unpacking... 6 Transport... 6 Storage... 6 Installing... 6 Exhausting Material Vapors... 6 Attaching to Parent Machine... 7 Observe when Attaching... 7 Adjusting... 7 Parallelism and Application Thickness... 7 Electrical Connection... 8 Laying Cable... 8 Heater... 8 Solenoid Valve... 8 Pneumatic Connection... 9 Connecting Control Air... 9 Connecting Heated Hose... 9 Using Second Open-end Wrench... 9 Connecting... 9 Disconnecting Relieving Material Pressure Motorizing Application Width Adjustment Signal Transmitter Rod... 11

4 II Table of Contents Operation Important When Using Polyurethane Application Materials (PUR) 12 Triggering Solenoid Valve Setting Temperature Maximum Operating Temperature Material Application Setting Application Width Daily Shutdown Maintenance Relieving Pressure Maintenance Table Visual Inspection for External Damage External Cleaning Bleeding Purging with Material Purging Purging with Cleaning Agent Troubleshooting Troubleshooting Table Repair Replacing Control Module Replacing Solenoid Valve Heater Cartridges, Temperature Sensor and Thermostat Nozzle Cleaning Assembling Processing Materials Technical Data Operating Data Electrical Data General Data Dimensions... 29

5 Applicator 1 Safety Instructions ATTENTION: Observe and follow all safety instructions, the general safety instructions included as a separate document, as well as the specific safety instructions in all other related documentation. ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. Introduction Intended Use Applicators of the series SB60-BoD may be used only to apply PUR and other hot melt adhesives commonly used in the book binding industry to glue the spines of books. Any other use is considered to be unintended. Nordson will not be liable for personal injury and/or property damage resulting from unintended use. Intended use includes the observance of Nordson safety instructions. Nordson recommends obtaining detailed information on the materials to be used. Unintended Use - Examples - The applicator may not be used under the following conditions: In defective condition When changes or modifications have been made by the customer In a potentially explosive atmosphere When unsuitable material is used When the values stated under Technical Data are not complied with. The applicator may not be used to process the following materials: Explosive and flammable materials Erosive and corrosive materials Food products.

6 2 Applicator Residual Risks In the design of the unit, every measure was taken to protect personnel from potential danger. However, some residual risks cannot be avoided. Personnel should be aware of the following: Risk of burns on the hot applicator: from hot material and when making adjustments Material fumes can be hazardous. Avoid inhalation. Note on Manual Definition of Terms Applicator The term application head is also used in Nordson literature. Melter General term for tank melters and bulk melters. Control Module The term module is also used in Nordson literature.

7 Applicator 3 Applicator Components Fig. 1 1 Handwheel Application width 2 Power cable (heater) 3 Air connection Solenoid valve 4 Solenoid valve 5 Control module 6 Guide plate 7 Hose connection 8 Screw plug

8 4 Applicator Function A melter pumps the material through a heated hose and into the applicator. The material is applied to the spine from underneath as soon as the Control module (1 ) is triggered (opened). The application width can be set continuously up to 60 mm. CAUTION: Do not set the application width to be greater than 60 mm. Otherwise the lateral guide plates can be damaged Fig. 2 1 Control module 2 Guide plates 3 Application slot 4 Hose connection Material inlet 5 Handwheel Application width Side Gluing 3 mm If the guide plates (2, Fig. 2) have a groove (Side gluing slot), material is also applied laterally. NOTE: Refer to the separate Parts List, Service Kits for the different guide plate models. CAUTION: When mounting the guide plates, apply high temperature grease to the surface between the guide plate and the body. Refer to page 28, Processing Materials! Groove (1 mm x 3 mm) for side gluing

9 Applicator 5 Volume Control The motion of two restricting pistons reduces the volume in the distribution channel when the application width is decreased; it increases to the same degree in a compensating chamber. By equalizing the volume, no material escapes and no air is sucked in when the application width is modified. So material is applied precisely beginning with the first book. Heating Electrical heater cartridges are used to heat the unit. The temperature is continuously measured by temperature sensors and is regulated by electronic temperature controllers. The temperature controllers are usually not part of the applicator. They are located in the melter electrical cabinet. Overtemperature Shutdown by Thermostat A thermostat in the body switches off the heater at approx 230 C or 180 C, depending on the model. ID Plate Fig field Type 2. field Serial number 3. field Nordson order number 4. field Year of construction 5. field Operating voltage [V], rated current [A], Operating voltage frequency [Hz]

10 6 Applicator Installation ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. Unpacking Unpack carefully. Then check for damage caused during transport. Reuse packaging materials or dispose of properly according to local regulations. Transport The applicator is a high precision, valuable part. Handle very carefully! Protect the nozzle from damage. Storage Do not store outside! Protect from humidity and dust. Protect the nozzle from damage. Installing When installing the applicator, the following points should be observed in order to avoid unnecessary effort later. Protect from humidity, vibrations, dust and drafts Ensure access to parts relevant for maintenance and operation When installing the unit, ensure that cables, air hoses and heated material hoses can not be bent, pinched, torn off or otherwise damaged. Exhausting Material Vapors Ensure that material vapors do not exceed the prescribed limits. Exhaust material fumes when necessary. Provide sufficient ventilation of the location where the unit is installed.

11 Applicator 7 Attaching to Parent Machine Screw the applicator onto the separate bracket (provided by the customer) in the parent machine. Observe when Attaching The application slot must be at a right angle to the direction of movement of the book spine. The inside edge of the rear book clamp must be aligned to the immobile guide plate of the applicator. Adjusting Parallelism and Application Thickness NOTE: A sensor gauge for adjusting the application thickness is contained in the Ship with kit. To achieve even application, adjust the applicator such that the application slot is parallel to the book spine. Adjust parallelism and the desired application thickness on the customer's bracket. NOTE: The application thickness on a book spine can be measured with the included measuring magnifier.

12 8 Applicator Electrical Connection ATTENTION: Observe voltage values found on the ID plate of the applicator and solenoid valves. ATTENTION: Risk of electrical shock. Failure to observe may result in personal injury, death, or equipment damage. Laying Cable ATTENTION: Ensure that cables do not touch rotating and/or hot components. Do not pinch cables and check regularly for damage. Replace damaged cables immediately! Heater 1. Connect the plug (1) to the melter electrical cabinet or to an external electrical cabinet. 2. Use safety clips - when available - to secure the plug connection. 1 Fig. 4 Solenoid Valve Connect the solenoid valve to a pattern controller. NOTE: Connecting lines can be part of a special cable harness.

13 Applicator 9 Pneumatic Connection Connect the applicator only to pressure-controlled and conditioned compressed air. Connecting Control Air 1. Connect the control module to the customer's air conditioning unit. 2. Set air pressure to 6 bar / 0.6 MPa / 87 psi. Connecting Heated Hose Using Second Open-end Wrench Use a second open-end wrench when connecting and disconnecting the heated hose. This prevents the hose connection on the unit from turning. If cold material can be found in the hose connection, these components (1, 2) must be heated until the material softens (approx. 70 C /58 F, depending on the material). CAUTION: Nordson melters are subjected to extensive testing prior to shipment. There may be some of the test material left in the hose connection. Fig. 5 Connecting ATTENTION: Hot! Risk of burns. Wear heat-protective gloves. 1. First connect the hose (3) electrically. 2. Heat applicator and hose until the material softens. 3. Screw on heated hose. Fig. 6

14 10 Applicator Connecting Heated Hose (contd.) Disconnecting ATTENTION: System and material pressurized. Relieve system pressure before disconnecting heated hoses. Failure to observe can result in serious burns. ATTENTION: Hot! Risk of burns. Wear goggles and heat-protective gloves. Relieving Material Pressure 1. Set the motor speed of the unit feeding the material to 0 min 1 (rpm); switch off motor(s). 2. Place a suitable container under the nozzle of the applicator to collect the adhesive. 3. Activate the solenoid valve electrically or manually (arrow). Do not use sharp objects! Repeat this procedure until no more material flows out. 4. Properly dispose of material according to local regulations. Fig. 7

15 Applicator 11 Motorizing Application Width Adjustment Observe the following when mounting a motor drive for adjusting the application width: CAUTION: Risk of injury from moving parts! Protect from direct contact. Comply with these values: Minimum torque [Nm] required Recommended maximum spindle speed * [min -1 ] NOTE: * Higher speeds increase wear to seals and bearing surfaces. Signal Transmitter Rod A signal transmitter rod (1, Fig. 8) can trigger a binder switch for a certain application width. 1 Fig. 8

16 12 Applicator Operation ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. Important When Using Polyurethane Application Materials (PUR) Triggering Solenoid Valve Setting Temperature Maximum Operating Temperature It is imperative that the following guidelines are complied with when processing polyurethane application materials (PUR): Wear respiratory protection when the maximum permissible concentration of hazardous substances is exceeded. Before prolonged standstill of the application system, purge with a suitable cleaning agent. Use only a cleaning agent recommended by the material manufacturer. Close open material connections airtight. When the system is to cease operation for only a short time, it suffices to coat the application slot generously with grease. CAUTION: Use only special high temperature grease. Refer to page 28, Processing Materials! Any other grease may cause the PUR material to cross link. CAUTION: Trigger the solenoid valve only when the applicator is heated to operating temperature! If the material is too cold, control module seals may be damaged. The procedure for setting the temperatures is described in the temperature controller manual. The temperature controller is not part of the applicator. They can be located e.g. in the electrical cabinet of the melter or in a separate electrical cabinet. 180 C / 356 F NOTE: The temperature setting is determined by the processing temperature prescribed by the material supplier. The maximum operating temperature for the product described here and the heated system components may not be exceeded. Nordson will grant no warranty and assume no liability for damage resulting from incorrect temperature settings.

17 Applicator 13 Material Application Factors that have a significant influence on application quality: Viscosity of the material (The heat effect and the duration thereof influence the viscosity) Material pressure (application pressure). It has to be determined by trial and error and then set depending on the desired application thickness, the application width, the machine speed and the adhesive viscosity. Medium application widths have proven to require a lower material pressure than small or large application widths Book spine condition. Setting Application Width CAUTION: Do not set the application width until the applicator is heated to operating temperature. CAUTION: Do not set the application width to be greater than 60 mm. Otherwise the lateral guide plates can be damaged Set the application width to the width of the book spine mm: 2. Re adjust application width during operation if required. - Fig. 9

18 14 Applicator Daily Shutdown To prevent the PUR material to be processed from hardening, open surfaces must be coated with grease. CAUTION: Use only special high temperature grease. Refer to page 28, Processing Materials. Any other grease may cause the PUR material to cross link. 1 Fig If necessary, remove material from the nozzle with a wooden or plastic spatula, or wipe off with a cloth. 2. Generously cover the application slot and side gluing slot with grease. 3. Set minimum application width.

19 Applicator 15 Maintenance ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: Maintenance is an important preventive measure for maintaining operating safety and extending the service life of the unit. It should never be neglected. Relieving Pressure ATTENTION: System and material pressurized. Before removing heated hoses and applicators, relieve system pressure. Failure to observe can result in serious burns. ATTENTION: Hot! Risk of burns. Wear goggles and heat-protective gloves. Fig Set the motor speed of the unit feeding the material to 0 min 1 (rpm); switch off motor(s). 2. Place a suitable container under the nozzle of the applicator to collect the adhesive. 3. Activate the solenoid valve electrically or manually (arrow). Do not use sharp objects! Repeat this procedure until no more material flows out. 4. Properly dispose of material according to local regulations.

20 16 Applicator Maintenance Table The maintenance intervals are general guidelines based on experience. Depending on operating environment, production conditions and hours of operation, other maintenance intervals may prove necessary. Unit part Activity Interval Refer to Entire application system Purge with cleaning agent When changing material, if the materials used cannot be mixed Before prolonged production interruptions, if PUR adhesive is processed Page 19 Observe information from material supplier Entire applicator Visual inspection Daily Page 17 External cleaning Daily Page 17 Control module Check performance When bleeding - Replace When malfunction occurs Page 22 Nozzle: Seals. sliding surface between mobile guide plate and body Lubricate When reassembling Weekly, when the application width is changed frequently Page 25 Replace seals When adjustable mouthpiece leaks

21 Applicator 17 Visual Inspection for External Damage ATTENTION: When damaged parts pose a risk to the operational safety of the unit and/or safety of personnel, switch off the unit and have the damaged parts replaced by qualified personnel. Use only original Nordson spare parts. External Cleaning External cleaning prevents pollution created by production from causing the unit to malfunction. CAUTION: Use only a cleaning agent recommended by the hot melt material manufacturer. Observe the Material Safety Data Sheet for the cleaning agent. CAUTION: Do not damage or remove warning labels. Damaged or removed warning labels must be replaced by new ones. ATTENTION: Hot! Risk of burns. Wear heat-protective gloves. Remove material residue only with a cleaning agent recommended by the material supplier. Heat with an air heater if necessary. Remove dust, flakes etc. with a vacuum cleaner or a soft cloth. 1. Remove material residue from the nozzle promptly with a soft cloth, before it chars. 2. Remove severe and hardened residue with a wooden or plastic spatula if necessary.

22 18 Applicator Bleeding Bleed the system when air or gas has penetrated it. 1. With the control module closed, go to the maximum application width (maintenance position). 2. Purge at the maximum application width at high speed until the adhesive flows out free of bubbles and clots. Switch the pump off again. 3. With the control module closed, reduce to the production application width. 4. Externally clean the nozzle. Refer to page 17. Purging with Material NOTE: When production is finished, purge the applicator with material if it will not be used for longer than three days. Purge with cleaning agent if PUR is being processed. Purging As the nozzle opens and closes, material charring is prevented around the surface nozzle, and the nozzle slot and spindle are cleaned. 1. With the control module closed, go to the minimum application width (5 mm). 2. With the control module closed, go to the maximum application width (maintenance position). 3. Purge at the maximum application width at high speed until the material flows out free of bubbles and clots. Switch the pump off again. 4. With the control module closed, reduce to the production application width. 5. Externally clean the nozzle.

23 Applicator 19 Purging with Cleaning Agent CAUTION: Use only a cleaning agent recommended by the hot melt material manufacturer. Observe the Material Safety Data Sheet for the cleaning agent. NOTE: When PUR was processed and the applicator will not be used for more than three days, purge with cleaning agent when production is finished. Set to the maximum width during purging. Rinse out cleaning agent just before beginning production again. 1. Maintain operating temperature. 2. Relieve pressure. Refer to Detach the heated hose from the applicator to prevent impurities from the melter and hose from being forced into the applicator during purging. 4. Purge melter and heated hose. 5. Screw the heated hose onto the applicator again and purge the applicator: As the nozzle opens and closes, material charring is prevented around the surface nozzle, and the nozzle slot and spindle are cleaned. a. With the control module closed, go to the minimum application width (5 mm). b. With the control module closed, go to the maximum application width (maintenance position). c. Purge at the maximum application width at high speed until only cleaning agent flows out. Switch the pump off again. d. With the control module closed, reduce to the production application width. e. Externally clean the nozzle. NOTE: When PUR adhesive is used, do not proceed until right before production is to begin again. 6. Purge the system (melter, hose, applicator) with the material currently in use to flush out the cleaning agent. NOTE: Properly dispose of the cleaning agent according to local regulations.

24 20 Applicator Troubleshooting ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. ATTENTION: Troubleshooting activities may sometimes have to be carried out when the unit is energized. Observe all safety instructions and regulations concerning energized unit components (active parts). Failure to observe may result in an electric shock. Troubleshooting Table When troubleshooting, other components of the application system may need to be considered. The troubleshooting table serves as an aid to qualified personnel. It cannot however replace targeted troubleshooting using e.g the wiring diagram and measuring instruments. It also does not include all possible problems, only those which most typically occur. Problem Possible cause Corrective action Refer to Applicator or parts thereof do not get hot Temperature on corresponding temperature controller set incorrectly or not at all Adjust temperature Page 12 Plug has no contact Secure plug - Fuses in melter or electrical cabinet defective Heater cartridge(s) defective Thermostat defective Disconnect unit from line voltage, check fuses and replace if necessary Have heater cartridge(s) checked by qualified personnel; replace if necessary Have thermostats checked by qualified personnel; replace if necessary Melter manual, wiring diagram - - Continued...

25 Applicator 21 Problem Possible cause Corrective action Refer to Material comes out of application slot Applicator has not yet reached operating temperature Wait until temperature has been reached, check temperature setting if necessary Page 12 Not enough material in melter Fill Manual for melter Control air not connected Connect Page 9 Melter pump is not working Check; replace if necessary Manual for melter Application slot blocked External cleaning Page 17 Cross-linked material in the nozzle Clean Page 25 Nozzle stem of control module stuck If the nozzle stem does not move when triggered, the application control module must be replaced Page 22 Material application is not exact Application slot or side gluing slot partially blocked Cross-linked material in the nozzle Distance between applicator and book spine not even External cleaning Page 17 Clean Page 25 Adjust applicator Page 7 Application quantity and book spine processing speed not attuned to one another Attune process variables to one another by trial and error - Material unsuitable Ask material manufacturer - Air within system Bleed Page 18

26 22 Applicator Repair ATTENTION: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. CAUTION: Before beginning any repair work, ensure that the applicator has been relieved of pressure. Refer to page 15, Relieving Pressure. Replacing Control Module ATTENTION: Hot! Risk of burns. Wear heat-protective gloves. CAUTION: To prevent damage to seals and nozzle stem, replace control modules only when the applicator is heated. CAUTION: The control module is attached to the body with an adapter plate (1). Do not detach the adapter plate. Otherwise the control module may not be positioned correctly Electrically heat cold applicator until material is liquid. 2. Relieve pressure. 3. Detach the compressed air connections. 4. Detach the solenoid valve plug. 5. Release fixing screws and replace control module. Fig. 12 CAUTION: Ensure that the old O-ring is removed and does not remain in the applicator body. 6. Screw new control module into place. 7. Reconnect compressed air. 8. Connect the plug to the solenoid valve. O ring Fig. 13

27 Applicator 23 Replacing Solenoid Valve Fig Fixing screw Solenoid valve plug 2 Solenoid valve plug 3 Fixing screw Solenoid valve 4 Solenoid valve 5 Seal 1. Switch off solenoid valve control. 2. Release the screw (1) and pull off the solenoid valve plug (2). 3. Release screws (3). 4. Remove the defective solenoid valve (4) and the old seal (5). 5. Screw on the new solenoid valve and the new seal using a torque wrench. Tighten the screws to 0.9 Nm. 6. Insert the solenoid valve plug again and secure with the screw. 7. Switch on the solenoid valve control again.

28 24 Applicator Heater Cartridges, Temperature Sensor and Thermostat ATTENTION: Risk of electrical shock. Before removing the electrical equipment covers, ensure that the applicator is deenergized. Failure to observe may result in personal injury, death, or equipment damage. 1. Detach the electrical equipment cover (2, Fig. 15) or one of the two brackets (1, Fig. 15). 2. Replace the defective part. 3. Screw on the electrical equipment cover or bracket again Fig Bracket 2 Electrical equipment cover 3 Heater cartridge

29 Applicator 25 Nozzle Detach the nozzle when seals and O-rings have to be replaced. ATTENTION: Hot! Risk of burns. Wear heat protective clothing, safety goggles, and heat protective gloves. 1. Heat applicator until material is liquid. 2. Remove the two screws (1 and 2, Fig. 16). 2 1 Fig Use the handwheel to turn the spindles out of the body. 4. Release all of the screws (3, Fig. 17) and detach the clamp bar (4, Fig. 17) Fig. 17

30 26 Applicator Nozzle (contd.) 5. Take out the mouthpiece (5, Fig. 17) Fig. 18 The seal (6) and piston (8) with the O-rings are not accessible. Release the screws (7) to remove the piston: NOTE: The O-rings are contained in the ship-with kit. Refer to separate parts list.

31 Applicator 27 Cleaning CAUTION: Use only a cleaning agent recommended by the hot melt material manufacturer. Observe the Material Safety Data Sheet for the cleaning agent. Clean the sliding surfaces on the body and mouthpiece: Remove material residue with cleaning agent. Heat with a hot air fan if necessary Remove severe and hardened residue with a wooden or plastic spatula if necessary. Assembling CAUTION: Use only special high-temperature grease! Any other grease may cause the PUR material to cross link. Refer to page 28, Processing Materials. Re-assemble the parts. Observe particularly: A. Lubricate seals, sliding and contact surfaces, screw threads B. Clamp bar fastening: If the screws (3) were removed: Correct order of spring washers Tighten the screws all the way. 3

32 28 Applicator Processing Materials High temperature grease Tube 250 g Cartridge 400 g P/N P/N Caution: Do not mix this lubricant with other lubricants! If necessary, first clean grease off of parts. Technical Data Operating Data Maximum operating temperature Overtemperature shutdown by 200 C 230 C 390 F 446 F Delivered until June 2014 thermostat (P/N ) Maximum operating temperature Overtemperature shutdown by 170 C 180 C 340 F 356 F Delivered beginning July 2014 thermostat (P/N ) Maximum operating air pressure 6 bar 0,6 MPa 87 psi Maximum operating pressure (material) 35 bar 3,5 MPa 508 psi Maximum material viscosity that can be processed Maximum application width Max. deviation of application quantities Heatup time mpas 10 Ms/m cp 60 mm < 15 %, depending on material 30 min Electrical Data Operating voltage (heater) 230 V AC Power consumption (heater) Body: 450 W Operating voltage (solenoid valves) 24 V DC Power consumption (solenoid valves) Control module: 2.5 W General Data Weight Approx. 6.5 kg Noise emission < 70 db(a) Degree of protection IP 44

33 Applicator 29 Dimensions Fig. 19

34 30 Applicator

Seal Sentry Series 10 Bead Detection System

Seal Sentry Series 10 Bead Detection System Seal Sentry Series 10 Bead Detection System Customer Product Manual P/N 321 289D02 This equipment is regulated by the European Union under WEEE Directive 2002/96/EC). See www.nordson.com for information

More information

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT Sponge Cleaner Manual P/N 768 651 A English Issued 05/03 NORDSON (UK) LTD STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected

More information

Hot Melt Material Applicator MC 7

Hot Melt Material Applicator MC 7 Hot Melt Material Applicator MC 7 Parts List P/N 735003A English Issued 2/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation

More information

GD-500 Bead Detection System

GD-500 Bead Detection System GD-500 Bead Detection System Customer Product Manual Issued 4/08 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments, and inquiries about

More information

Hot Melt Application Head Series PW...

Hot Melt Application Head Series PW... Hot Melt Application Head Series... Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

AltaSpray Plus Applicators

AltaSpray Plus Applicators AltaSpray Plus Applicators Customer Product Manual Issued 5/3 This document contains important safety information Be sure to read and follow all safety information in this document and any other related

More information

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD Electropneumatic Hot Melt Application Heads Manual P/N 409 090 A English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson

More information

FillEasy C Adhesive Feed System

FillEasy C Adhesive Feed System FillEasy C Adhesive Feed System Customer Product Manual Issued 5/10 This document contains important safety information Be sure to read and follow all safety information in this document and any other

More information

Hot Melt Material Applicator MC 4420

Hot Melt Material Applicator MC 4420 Hot Melt Material Applicator Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is

More information

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Manual - English - Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note After approx. December 2003, this manual applies to the entire series.

More information

Bulk Melters AltaPail

Bulk Melters AltaPail Bulk Melters AltaPail Manual - English - Edition 02/12 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with the following P/N: 7165698 7157455 7157502 7157503 Order number

More information

DuraDrum Bulk Melters DD200

DuraDrum Bulk Melters DD200 DuraDrum Bulk Melters Manual English Issued 11/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Series AD-31 and Series L4 Extrusion Handguns

Series AD-31 and Series L4 Extrusion Handguns Series AD-31 and Series L4 Extrusion Handguns Customer Product Manual Issued 5/05 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation

More information

LA 820 / LA 820 RC Liquid Adhesive Gun

LA 820 / LA 820 RC Liquid Adhesive Gun Liquid Adhesive Gun Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by

More information

Hot Melt Material Applicator MC 6

Hot Melt Material Applicator MC 6 Hot Melt Material Applicator Manual P/N 403 022 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Piston Pump for 200 l Drums Bulk Melters BM 200 with Piston Pump for 200 l Drums Manual P/N 464 937 B - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number

More information

Level Monitor LA 100

Level Monitor LA 100 Level Monitor LA 100 Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which

More information

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Manual P/N 464 958 C - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order

More information

Hot Melt Applicator MC 405 for Foil Bags

Hot Melt Applicator MC 405 for Foil Bags Hot Melt Applicator for Foil Bags Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 8015767 8022490 8027924 8037680 8018042 8023117 8031127

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

Drum Melters DG 21 / DG 201

Drum Melters DG 21 / DG 201 Drum Melters DG 21 / DG 201 Manual P/N 464 839 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products

More information

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Material Applicator MC 12 / MC 24 Hot Melt Material Applicator Manual P/N 403 076 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

Hot-melt adhesive extruder EEX40

Hot-melt adhesive extruder EEX40 Hot-melt adhesive extruder EEX40 Manual 110900563/001 - English - Nordson Deutschland GmbH Buchholz-Mendt GERMANY Note This manual applies to the entire series. Part number P/N = 7549584 Notice This is

More information

Envirocoat Twin Cyclone Powder Coating Booth

Envirocoat Twin Cyclone Powder Coating Booth Envirocoat Twin Cyclone Powder Coating Booth Manual P/N 779166 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue

More information

Powder Conditioning System

Powder Conditioning System Powder Conditioning System Manual P/N 779168 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Table I Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF,

More information

Hot-melt adhesive extruder EEX100

Hot-melt adhesive extruder EEX100 Hot-melt adhesive extruder EEX100 Manual 111121287/001 -- English -- NordsonDeutschlandGmbHBuchholz--MendtGERMANY Note This manual applies to the entire series. Part number P/N = 7552471 Notice This is

More information

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK Manual P/N 768 643 A English NORDSON (UK) LIMITED STOCKPORT UK Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original

More information

Fixed Reclaim System

Fixed Reclaim System Fixed Reclaim System Manual P/N 779163 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF, Can Works, Century,

More information

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQX Manual 110717869/001 -- English -- Nordson Deutschland GmbH D Buchholz--Mendt D GERMANY Note This manual applies to the entire series. erial no. 110717869/001

More information

Replacing a Gun Thermostat

Replacing a Gun Thermostat Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Liquid Adhesive Detection System Alarm Box

Liquid Adhesive Detection System Alarm Box Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

Non-RTD Hot Melt Hose Replacement

Non-RTD Hot Melt Hose Replacement Instruction Sheet P/N 7C 0 Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result

More information

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

ColorMax Cyclone Cleaning Kit

ColorMax Cyclone Cleaning Kit Instruction Sheet P/N 637 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description See

More information

CleanSpray System Operation

CleanSpray System Operation Nordson Corporation OPERATOR S CARD P/N 108684C CleanSpray System Operation Introduction The individual manuals for the CleanSpray Gun, CleanSpray Controller and Model 25B Pump are included with each component.

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Platen Heater Pad Replacement

Platen Heater Pad Replacement Instruction Sheet P/N Platen Heater Pad Replacement WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range MAKE CLEANING SAFER NEW TECHNOMELT Your Machine Cleaning Guide & Hotmelt Cleaner Range 2 TECHNOMELT Your Machine Cleaning Guide & Hotmelt Cleaner Range Do you know the advantages of regular and thorough

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

Operating Instructions for Reka Hot-Melt Glue Applicators

Operating Instructions for Reka Hot-Melt Glue Applicators Operating Instructions for Reka Hot-Melt Glue Applicators TR 700 TR 70 TR 80 TR 60 TR 50.4 TR 55 Table of Contents 1. Product Description 3 2. General Safety Instructions 4 3. Safety Measures to be taken

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Dosing system. Commissioning and maintenance manual eco-pen300

Dosing system. Commissioning and maintenance manual eco-pen300 Dosing system Commissioning and maintenance manual eco-pen300 Item number 20506 Print 21.2.12 Contents 1 This Manual 5 2 The dispenser 5 3 Safety 5 4 Starting up for the first time 6 4.1 Inserting the

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

Rhino AB Upper Check Valve Replacement

Rhino AB Upper Check Valve Replacement Instruction Sheet P/N 6 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Replace the Upper

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

BQ-260/260L. Important Information BOOK BINDER

BQ-260/260L. Important Information BOOK BINDER BOOK BINDER BQ-260/260L Important Information - This manual is designed to help you to install, operate and maintain Perfect Binder BQ- 260/260L. Read, understand and keep this manual in a safe and convenient

More information

Pneumatic agitator A MAN R

Pneumatic agitator A MAN R Pneumatic agitator A MAN R Operation manual MAG00001EN, V05 www.durr.com N6804... Dürr Systems AG Application Technology Carl-Benz-Str. 34 74321 Bietigheim-Bissingen Telephone: +49 7142 78-0 Internet:

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE Operating Instructions PowerFill Automatic Granulate Conveyor for perfectmelt SE - 020100 - 2 Contents Introduction 4 Safety instructions 5 Safety measures with respect to the adhesive 5 Safety measures

More information

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17)

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17) K 2 Basic Operating Instructions Please read the operating instructions carefully before using the unit. 59679030 (05/17) Contents Safety instructions............. 3 Description of the Appliance......

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

Section 11. Electrical System. 42--CF200--MA--08 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved

Section 11. Electrical System. 42--CF200--MA--08 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved ection 11 Electrical ystem 11-0 Electrical ystem Table of Contents i Table of Contents ection 11 Electrical ystem 1. Introduction... 11-1 Electrical Operation... 11-1 Heating Zones... 11-2 2. Electrical

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range MAKE CLEANING SAFER NEW TECHNOMELT Your Machine Cleaning Guide & Hotmelt Cleaner Range 2 TECHNOMELT Your Machine Cleaning Guide & Hotmelt Cleaner Range Do you know the advantages of regular and thorough

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions AirStar Clinical Air Compressor AS60, AS90 and AS0 Installation & Operating Instructions Contents Important Information. Notes on this documentation................ 4. Warnings and symbols................

More information

INSTRUCTION MANUAL MODEL: 690E

INSTRUCTION MANUAL MODEL: 690E 1 INSTRUCTION MANUAL ALEKO Drywall Sander MODEL: 690E READ THROUGH CAREFULLY AND UNDERSTAND THESE INSTRUCTIONS BEFORE USE Visit our web site for more great products, parts and accessories: 2 3 4 5 6 Caution!

More information

USER MANUAL UN-200V / UN-200VH

USER MANUAL UN-200V / UN-200VH USER MANUAL UN-200V / UN-200VH CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City, UT 84104 WEB www.lacotech.com

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

Models Series Series

Models Series Series Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload

More information

HD Kompakt Service Manual

HD Kompakt Service Manual HD Kompakt Service Manual English 5.906-583.0 Rev. 00 (08/13) 1 1 Contents 1 Contents.................................................... 2 2 Preface.....................................................

More information

HKF 8180 Operating instructions

HKF 8180 Operating instructions Operating instructions EN Version 1.0en /Edition 05/2013 Contents 1 Important basic information... 3 1.1 Limitation of liability... 3 1.2 Operator's responsibilities... 3 1.3 Documentation... 3 1.3.1 Content

More information

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 500 NORTH OAKWOOD RD LAKE ZURICH, IL,60047 PHONE # (847)

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015 ANLAGENBAU HEAT EXCHANGER Table of Contents 1.0 General Information 1.2 User Instructions 1.3 Proper Use 1.4 General Safety Rules 2.0 Design and Function 3.0 Installation 3.1 Setting up the Plate Heat

More information

Operation Manual R205BV, R209BV

Operation Manual R205BV, R209BV Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,

More information

RX550i Electric Pressure Washer

RX550i Electric Pressure Washer RX550i Electric Pressure Washer READ THIS MANUAL CAREFULLY BEFORE USE FAILURE TO DO SO MAY RESULT IN INJURY, PROPERTY DAMAGE AND MAY VOID WARRANTY. KEEP THIS MANUAL FOR FUTURE REFERENCE. Products covered

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above Installation and Operation Manual CLEARVIEW DAY COVER To view a video scan the QR code above CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

More information

MODULAR AUTOMATIC GRANULAR ICE FLAKER

MODULAR AUTOMATIC GRANULAR ICE FLAKER MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

Models Series Series

Models Series Series Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Operational Instructions. Glue Applicator MS Translation from German to English

Operational Instructions. Glue Applicator MS Translation from German to English Operational Instructions Glue Applicator MS 200 Translation from German to English Table of Contents Product Description 1 General Safety Instructions 2 Safety Measures to be taken during Operation 3 Start-up

More information

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2 Contents 1 General remarks... 5 2 Safety... 6 2.1 Safety remarks... 6 2.1.1 Signal words... 6 2.1.2 Pictograms... 7 2.2 Qualification of deployed personnel... 7 2.3 Intended application... 7 2.4 Application

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

User s Information Manual

User s Information Manual 48AJ,AK,AW,AY020-060 Single-Package Rooftop Gas Heating Units with COMFORTLINK Controls and Scroll Compressors User s Information Manual NOTE TO INSTALLER This manual should be left with the equipment

More information

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original) Montageanleitung (Original) (Translation of the original) DE MA_ 1.0 06/2014 Taperlock Clamping-bush system _0 _1 Fixed hub Inlet nozzle with IMV 1. Revision index Revision Date MA_ 1.0 06/2014 2. Safety

More information

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit INSTALLATION GUIDE Yellow Jacket Misting System For help, call 1-877-BIG-FANS or visit www.bigassfans.com READ AND SAVE THESE INSTRUCTIONS WARNING AND CAUTION SYMBOL Indicates a hazard with a medium level

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information

Service: to SLK Laboratory Hot Plates glass made of ideas

Service: to SLK Laboratory Hot Plates glass made of ideas SLKServiceV04eng.doc 17 Version: 04.07.2002 Contents Page Contents... 18 1 Safety information... 20 2 Introduction... 21 2.1 Required tools...21 2.2 Required measuring and testing means...21 2.3 Setting

More information

Product Manual for Pneumatic Reka Glue Guns

Product Manual for Pneumatic Reka Glue Guns Product Manual for Pneumatic Reka Glue Guns www.pakarte.com TR 60 LCD TR 70 LCD Translation from German to English TR 80 LCD TR 55 LCD TR 700 TR 50.4 TR 50.4 25 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

Portable Pressure Washer

Portable Pressure Washer RX550i Thanks for purchasing our latest portable pressure washer. Whether it be for light rinsing or for power stripping, this pressure washer is built for quick and easy high speed cleaning. To get the

More information

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½ SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½ OPERATION AND SERVICE GUIDE O-820_R FEBRUARY 2013 Refer to Bulletin P-201 and Parts Lists: P-7200, P-7250. SAFETY PRECAUTIONS BEFORE STARTING PUMP 1. Read

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions Operating Instructions Accessory Units Melitta Cafina XT Series Melitta Professional Coffee Solutions Contents General... 4. Manufacturer information... 4.2 About these instructions... 4.3 Explanation

More information

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10 ColorMax Engineered Booth Customer Product Manual Issued 11/10 For parts and technical support, call your nearest Finishing Customer Support Centre. Find your nearest centre at www.nordson.com/directory

More information